Military Engineer Services - Maharashtra

39768554 tender for provision of 06 nos security watch towers at hemrl, pune; 1 lumpsum price worked out by the contractor for construction of watch tower with rcc framed structure ( g+2 ) complete all as shown on drawings and as specified. 2 lump sum price worked out by the contractor for “site development, earthwork and excavation as listed in schedule ‘a’ part iirepresenting_______ % ______________ percent above / below the lump sum price of `10, 36, 344.72 inserted by the mes in schedule ‘a’ part ii 3 lump sum price worked out by the contractor for “internal electrification” as listed in schedule ‘a’ part iii representing__________ % ____________ percent above / below the lump sum price of `3, 98, 415.66 inserted by the mes in schedule ‘a’ part iii 4 lump sum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’ part iv representing__________ % ____________ percent above / below the lump sum price of ?37, 495.56 inserted by the mes in schedule ‘a’ part iv 5 lump sum price worked out by the contractor for roads / paths / culverts” as listed in schedule ‘a’ part v representing______ % _________________ percent above / below the lump sum price of `4, 62, 888.00 inserted by the mes in schedule ‘a’ part v 6 lump sum price worked out by the contractor for external electric supply” as listed in schedule ‘a’ part vi representing_______ % __________________ percent above / below the lump sum price of `12, 74, 315.10 inserted by the mes in schedule ‘a’ part vi 7 lump sum price worked out by the contractor for external water supply” as listed in schedule ‘a’ part vii representing_______ % __________________ percent above / below the lump sum price of `3, 22, 790.38 inserted by the mes in schedule ‘a’ part vii 8 lump sum price worked out by the contractor for “sewage disposal” as listed in schedule ‘a’ part viii representing_______ % _________________ percent above / below the lump sum price of `2, 33, 651.38 inserted by the mes in schedule ‘a’ part viii 9 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’ part ix representing_______ % _________________ percent above / below the lump sum price of `14, 10, 891.53 inserted by the mes in schedule ‘a’ part ix 10 lump sum price worked out by the contractor for “special item of work” as listed in schedule ‘a’ part x representing_________ % __________________ percent above / below the lump sum price of `20, 161.00 inserted by the mes in schedule ‘a’ part x 11 this schedule is not prepriced by mes and the prepriced rate indicated in col 5 as ?0.00 indicates this fact only. the tenderer is required to quote their rates in column 6. this schedule constitutes sl. item nos. 23.00 to 110.00. 12 internal electrifications&f, enviroment friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge lit led luminaire comorising of high brightness led 10 watt with polycarbonate housing integrated electronic driver complete with all accessories including internally prewired all as specified and directed.make: havells cat no. hexaft10wled857ssymbopc / philips / crompton greaves / fortune arrt. 13 s&f, led tube light fitting 1 x 20 w, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs20wled865spcss / philips / crompton greaves / fortune arrt. 14 s&f, led tube light fitting 1 x 10 w, 2 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs10wled865spcss / philips / crompton greaves / fortune arrt. 15 s&f, led building security luminaries 25 watts pressure die cast aluminum housing with ip 66 and replaceable integrated electronic driver led as light sources housing complete with all accessories internally prewired and suitable for pole 40 mm dia all as specified and directed.make: cat part no. endurasundownsl25wled765pasybopcihd of havells / philips / crompton greaves / fortune arrt. 16 s&f, suitable shape street light fitting bracket made out of gi pipe 40 mm dia med grade or of suitable size as per requirement and shape, clamps made out from ms flat of size 40 mm x 6 mm with nuts and bolts ( length of pipe should not less than 1.5 m ) and applying single coat of aluminium paint over a coat of red primer painting complete all as specified and directed by engineer in charge. 17 s&f, ventilating fan metal type 300 mm sweep ac 230 volts 900 rpm with all accessories and louvers including provisioning of hole in wall, making good the disturbed surfaces of wall complete. make: havells venti air ds / crompton greaves / usha. 18 s&f, spn distribution board double door flush type all as per is 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories all as specified and directed by engineer in charge.note: mcbs for out goings shall be measured and paid for separately under relevant items. 19 s&f, connecting and testing mcb single pole and neutral ( mcb spn ) 230 volts of capacity 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 20 s&f, connecting and testing mcb single pole ( mcb sp ) 220 volts of capacity 6 to 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 21 supply, fixing & commissioning of cpri approved factory made lt cubical panel board out door type conforming to is / iec 61439 1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415 volts, 3phase, 50hz having aluminium bus bar of capacity 200 amps tpn duly colour coded and for neutral supported with dmc / smc insulators colour coded with heat shrinkable sleeve having short circuit current with minimum 65ka for one second and suitable for internal connection including instaneous over load and earth fault relays complete with digital type volt meter and ammeterincluding suitable range of cts of metering, selector switches for volt meter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels, nut bolts, washers etc, including control accessories: 22 ( a ) incoming mccb 4 pole 415v, 100 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 25 ka 01 no. ( b ) outgoing mccb 4 pole 415v, 63 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 16 ka 02 nos. ( c ) outgoing mcb spn, 32 amps 10 ka c series 230v ac supply 01 no. ( d ) panel mounted type digital multifunctional energy meter a, v, z, kw, pf ct operated, lt 3 phase, 4 wire, including ct ratio 400 / 5 01 no. ( e ) led indicating lamps sets ryb 01 set ( f ) astro time switch 01 no. 23 s&f, two way bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete of size 15mm dia pipe complete all as specified and directed. 24 s&f, 1.2m long chromium plated health foucet including holder fixed to wall complete all as specified and directed by engineer in charge. 25 m&l for cutting of roads / plinth for removal / lalying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed by engineer in charge.note: width 450 mm and depth 600 mm to be excavated for road cutting. 26 construction of septic tank of 5 users capacity, excavation in hard soil, foundation in pcc, brick work in cm 1:4, rcc manholes cover, vent shaft and sludge chambers complete all as specified and directed and shown on td drawings. 27 construction of soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of fly ash brick masonary in cm, rcc cover slab in m25 / sfrc cover, interconnecting pipes of rcc / dwc complete filled with brick bats complete all as specified and directed and shown on td drawings. 28 supply, fix, connecting, testing & commissioning of high intensity long range, auto swivel, led search light, beam range 500 meters ( min ) , 1x200w, single, led light, efficiency >130im / w, pf>0.95, cct 5500k 6500k, optional grade pmma pc lens, anti uv oxidation, narrow beam 8 degree, die cast lm6 body with air fins, fully powder coated, working voltage 150to270, 50hz constant current, reflector / lens efficiency >90% average lux level at 5 meter 9000 ( min ) with circle of approximately 600mm, ip 65, confirming to lm79 / lm80 search light should be installed on disc of revolving mechanism with suitable motor gear unit and design such to rotate 360 degree continuously over the night in horizontal plane with speed controller ( 1 to 10 rpm ) & r / f buttons and inbuilt push to tilting option upto 45 degree. a separate wall mounted wired control panel ( consist of mcbs, v meter, fuse, led indicators ) with smooth and safe operation remotely including revolving mechanism fully covered with weather & rust proof fiber box with maintenance window / door with provision of 4 nos foundation holes at bottom for proper installation complete all as specified and directed.make: cat no. mrsl lrfll25 pc20 of make kalin or equivalent make approved by ge....

Central Railway - Maharashtra

39687034 supply of pu aluminum paint ( two pack ) as per rdso specification no m&c / pcn / 100 / 2018. [ warranty period: 30 months after the date of delivery ] ...

Rural Development Department - Maharashtra

39682464 supply of various items for gram panchayat karyalaya at mukramabad tq. mukhed dist. nanded , 1 ) smart tv takai smart 4k led tv 40inch, m / no 4003s =05 2 ) computer set dell monitor, dell keyboard, dell mouse, assemble cpu, 4 gb ram, 1 tb hd, cabinet, i3 processor, 4th gen. windows 7 & anti virus = 03 , 1 ) table office table 2.5x5=05 2 ) ex. chair maharaja rev. double handle chair=04 3 ) chair fiber chair = 60 4 ) kapat office kapat 6.5 ft= 04 5 ) sound system takai sound sytem tk 150 15 =01 , 1 ) fan ceiling fan = 04 2 ) chair fiber chair lotus= 12 3 ) table table 2×4 = 04 4 ) sound takai sound tk 150 15 = 02 5 ) ????? office kapat 6.5 ft = 04 6 ) ro ro water filter 50 ltr = 02 , 1 ) 36 watt led street light osaram 36 watt ( ip 65 water proof ) luminary aluminum dicast body street light bracket as per csr 1.5 sqmm 4 core cable of isi mark 14 mtr. installation of street light. dpmcb 40 a to 63 a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb pole clamp made from 50x10 mm ms flat for pole or pipe, post complete duly painted with one coat of red oxide and two coats of aluminum paint.= 80 , 1 ) shegdi gas shegdi = 08 2 ) water tank steel ss water tank = 08 3 ) table office table 2x3 = 08 4 ) chair lotus chair= 16 5 ) ????? office kapat 5.5 ft = 08 , 1 ) true view cc tv camera duel lens 4 g solar mini pan tilt camera, audio video recording with high quality video, intelligent detection human detection based recording and push notification, storage sd card up to 256 gb and cloud storage, combined zoom 10x zoom, full deplex audio intercom, mobile app, night vision.= 15 2 ) sd cardmemory card 64 gb = 15...

Rural Development Department - Maharashtra

39480971 supply material for annual construction grampanchayat chirva year 2023 24 , sand bhandara , sand local kanhan river , soft murum , metal 80 mm , metal 40 mm , metal 20 mm , metal 6 mm , bricks table sample (red) , opc cement isi mark , ppc cement isi mark , dust , steel 20 mm , steel 16 mm , steel 12 mm , steel 10 mm , steel 8 mm , steel 6 mm , kota stone , submershible pump 7.5 hp , submershible pump5 hp , submershible pump3 hp , submershible pump1 hp , lead 8 mm , rcc benchess , hard murum , pelving block hydrolick mode , pelving block rubber mode , cement pipe 300 mm , cement pipe 450 mm , cement pipe 600 mm , cement pipe 900 mm , mixer machin , vibrator , water tanker , road roller , centring plat , khille , centring tar , tree gard zaliwala 5 fut , bricks table sample (cement) , covering block , cheker tiles (cement) , cheker vetrified tiles , cerimice tiles , koda , wall tiles , floor tiles , greynite , green marble , kadapa , naylon rassi , quring panni , naryal rassi , centring nail , ancore bord , pawda , tikas , sabble , pvc ghamela , steel ghamela , 14 inch steel cutting blade , 4 inch steel cutting blade , steel frame , steel ralling , steel chaddar , steel window , cement window , profile sheet , gi sheet , pvc sheet , m/s pipe , concrete cheker , lw plus liquid , urp liquid , water proof pawder , groute powder , crake seal , mseal , obd distemper , weather cote paint , cement colour , birla white cement , eagle cem , snow cem water proof cement paint , chhuna , pop powder , cement pipe 150 mm , red oxide primer , tarpin oil , stainer , sine paper , oil primer , alluminium paint , glass putty , wall putty , roller brush , painting brush , zaddu brush , rubber paint , screw , door kit , acid , fenile , bleeching powder , casting soda , rassa , garden pipe , handle , chember , hdpe pipe , green net , kharata , jali , trilpal , chenling jali , kata tar , cement pol , doors , alluminium door , glass mirror , plywood sheet , sandas sit , murga , jents urinal , section pipe , puc pipe 160 mm 6 kg , puc pipe 160 mm 4 kg , puc pipe 140 mm 6kg , puc pipe 140 mm 4kg , puc pipe 110 mm 6kg , puc pipe 110 mm 4kg , pvc pipe 90 mm 6kg , pvc pipe 75 mm 4kg , pvc pipe 63 mm 4kg , pvc pipe 90 mm4 kg , pvc pipe 75 mm 6kg , pvc pipe 63 mm 6kg , pvc socket , pvc bend , pvc elbo , pvc tee , gi pipe90 mm , gi pipe 63 mm , gi pipe 50 mm , gi bend 90 mm , gi bend 63 mm , gi elbo 90 mm , gi elbo 63 mm , air wall , dack foot bend , c i raod way , maitaincoupling 90 mm , maitaincoupling 110 mm , maitaincoupling 160 mm , maitaincoupling 200 mm , maitaincoupling 63 mm , maitaincoupling 75 mm , cid joind , cid mechanical joind , non return valve 80 mm , cpuc pipi , cpuc socket , cpuc elbo , cpuc tee , belcha heavy , puc reducer , pvc tellpease plus flanch , c.i. flanch , pvc cid coplar , solvent solution , ladies urinal , wash basinig , ms steel sine bord with painting , walmasta paint , loxol oil paint , alluminium sliding window , bision emulsion , febrication tin sheet , febrication grill work , jcb...

Rural Development Department - Maharashtra

39447037 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Department Of Atomic Energy - Maharashtra

39439148 bids are invited for coating self priming surface tolerant high solids epoxy primer , high solids acrylic aliphatic polyurethane finish coating of eau de nil , high solids acrylic aliphatic polyurethane finish coating of french blue shade , high solids acrylic aliphatic polyurethane finish coating of light brown shade , high solids acrylic aliphatic polyurethane finish coating of oriental blue shade , high solids acrylic aliphatic polyurethane finish coating of a.c. grey shade , high solids acrylic aliphatic polyurethane finish coating of white , high solids acrylic aliphatic polyurethane finish coating of black , high solids acrylic aliphatic polyurethane finish coating of signal red shade , high solids acrylic aliphatic polyurethane finish coating of salmon pink shade , high solids acrylic aliphatic polyurethane finish coating of light orange , high solids acrylic aliphatic polyurethane finish coating of sky blue shade , epoxy thinner surface tolerent , pu thinner , high build high solids heavy duty coal tar epoxy coating , epoxy thinner heavy duty coal tar , high build high solids self priming surface tolerent glass , epoxy thinner glass flake epoxy coating , high build inorganic zinc rich alkyl silicate primer , thinner with inorganic zinc silicate , heat resistent aluminium paint , water based rust converter of marine grade high solids acrylic aliphatic polyurethane finish total quantity : 4740...

Department of Agricultural Research and Education - Maharashtra

39420656 renovation / repairing of existing screen house no. 5 at icar ccri nagpur ; 1 renovation of existing screen house no.5 2 dismantling of roofing including rides, hipes, valleys and gutters etc. and stacking the material within 50 meters lead ( 11050 sqft ) 3 dismantling of damaged / condemned unusable side wall, rcc benches, including support pillars ( 10 cum ) 4 dismantling of ss mesh fixed with ms strip screw etc ( approx. 550 sqft ) 5 dismantling of steel structure ( approx. 810 sqft ) 6 repair and modification of structure including improving height up to 1.0 m, using 2 mm thick isi standard hot dip gi sq. minimum 48x48 mm, minimum 38x38 mm, minimum 32x32 mm, complete as required , provision of roof vent minimum 75 cm x entire length protected by ss mesh ( approx. 810 sqft ) 7 replacement of roof covering with uv stabilized polycarbonate sheets with minimum 6 mm thick ( 1030 sqft ) 8 replacement of side jail inside maximum upto 80 mesh ( approx. 1100 sqft ) and outside maximum upto 60 mesh thick ( 1100 sqft ) 9 reconstruction of damaged bricks wall. ( approx. 360 sqft ) 10 re plastering of both side wall of the screen hose ( approx. 810 sqft ) 11 replacement of entry room double door with hardware ( 2.1 x 1.5 m ) . 12 flooring made of pcc ( 1:5:10 ) minimum 3 4 thick and over that minimum 2 cc ( 1:2:4 ) with proper drainage slope. ( approx. 810 sqft ) 13 replacement of exhaust fans 600 mm with louvers ( 2 nos. ) ( branded company with isi certification ) 14 supply and installation of air coolers comprising heavy duty industrial fans 600 mm ( branded company with isi certification ) , cooling pads ( branded ) , water recirculation system sensor based opertion ( 2 nos. ) 15 replacement of electric fitting isi mark and copper wire complete with light / power points for pumps, fans and other miscellaneous use as per requirement 16 painting structure with aluminium paint of reputed brand ( dual coating ) 17 painting of walls with cement paint of approved color ( reputed brand ) ( dual coating ) and shade ( approx. 890 sqft ) 18 provision for water supply outlet with pvc tank 1000 ltr with 1.0 hp pump, pvc pipe and fitting and bal valve 19 net screen 50% green colour with manual opening / closing inside structure 20 construction of plinth protection 600mm wide in cc 1:2:3 over dry brick bat ( 75+50 mm thick ) all around the structure 815 sqft 21 provision of platform made of bricks pillar and kaddpa stone top approx 350 sqft 22 connection entry room to main approach road with path in 1:2:4 cc approx 310 sqft 23 abc...

Rural Development Department - Maharashtra

39216263 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Department Of Defence - Maharashtra

39205422 bids are invited for procurement of ahcp consumables knife cutter , brush bristle 1 inch , brush hand nylon 1 inch , brush paint bristle half inch , brush paint bristle 1 inch , brush pencil writing , masking paper 2 inch , scissor , teflon tape , white spirit , mek , wax polish liquid , glycerin , paint remover , corrosion prevention compound , polykote silicon compound , molykote grease , multifunctional fluid spray , anticorrosive fluid spray , hand spray , corrosion remover , anticorrosive spray , rtv 732 adhesive silicon , thinner universal , epoxy primer hardner plus thinner , paint gray , paint oxford blue , paint po red , paint white , paint golden yellow , paint red orange , paint non skid black , heat resistive aluminium paint , paint silver grey , paint black , rubber adhesive heavy duty , perspex polish , locklite 222e , gloves pvc fabric , adheshive tape 38mm total quantity : 3768...

Central Railway - Maharashtra

39103188 supply of aluminium paint brushing, bright finishing for general purpose to is: 2339 / 2013 ( reaffirmed 2018 ) and rdso amdt no.1a rev 1.0 as an additional requirement. packing in 4 ltrs. dual container ( alluminium paste packed in polyurethane bags and dipped in 4 ltrs. containers ) . [ warranty period: 12 months after the date of delivery ] amm ( carshed ) sanpada , cr maharashtra 5000.00 litre...

Mira Bhaindar Municipal Corporation - Maharashtra

38954916 supply and installation of cctv components at mbmc properties, buildings, gardens, play grounds, esr, lake surroundings, statues, hospitals, health centers, schools, cemeteries, and other locations in mbmc area=2 item no 1supplying & erecting 4mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 3 item no 2supplying & erecting 5mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 4 item no 3supplying & erecting 8mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 5 item no 4supplying & erecting 4mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 6 item no 5supplying & erecting 5mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 7 item no 6supplying & erecting 8mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 8 item no 7supplying & erecting 4mp ip bullet outdoor camera ir dist upto 80 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 9 item no 8supplying & erecting 5mp ip bullet outdoor camera ir dist upto 80 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 10 item no 9supplying & erecting 4mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 11 item no 10supplying & erecting 4mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic, built in micro sd slot upto 256gb (market rate) 12 item no 11supplying & erecting 5mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 13 item no 12supplying & erecting 5mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic,built in micro sd slot upto 256gb (market rate) 14 item no 13supplying & erecting 8mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 15 item no 14supplying & erecting 8mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic,built in micro sd slot upto 256gb (market rate) 16 item no 15supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 30 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 17 item no 16supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 30 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 18 item no 17supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 50 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 19 item no 18supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 50 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 20 item no 19supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 100 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 21 item no 20supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 100 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 22 item no 212mp ip ptz 25x optical zoom 150mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 23 item no 224mp ip ptz 25x optical zoom 100mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 24 item no 23ptz joystick with 1 rs 232, 2 rs 485,used to control ptz dome, four dimensional joystick (market rate) 25 item no 24ptz joystick with 102 screen, 1 * rs232,1 * rs485,1 * hdmi output,1 * rj45 port, 1 * usb interface,1 * standard 3.5mm audio jack, four dimensional joystick (market rate) 26 item no 25supplying & erecting 4 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 27 item no 26supplying & erecting 4 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth, 4 rj45 10m/100m poe network interfaces, 1 hdd support each with upto 6tb (market rate) 28 item no 27supplying & erecting 8 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 29 item no 28supplying & erecting 8 channel nvr with up to 320 mbps incoming bandwidth & 180 mbps outgoing bandwidth, 2 hdd support each with upto 8tb (market rate) 30 item no 29supplying & erecting 8 channel nvr with up to 80 mbps incoming bandwidth & 64 mbps outgoing bandwidth, 8 rj 45 10m/100m self adaptive ethernet interface,2 hdd support each with upto 10tb (market rate) 31 item no 30supplying & erecting 16 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 32 item no 31supplying & erecting 16 channel nvr with up to 320 mbps incoming bandwidth & 320 mbps outgoing bandwidth, 2 hdd support each with upto 8tb (market rate) 33 item no 32supplying & erecting 16 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 4 hdd support each with upto 10tb (market rate) 34 item no 33supplying & erecting 32 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 4 hdd support each with upto 10tb (market rate) 35 item no 34supplying & erecting 32 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 8 hdd support each with upto 10tb (market rate) 36 item no 35supplying & erecting 64 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 8 hdd support each with upto 10tb (market rate) 37 item no 36supplying & erecting big size ( approx 12 14 inch ) outdoor shockproof, rustproof,weatherproof junction box with pole mounting clamp for poe switch, media converter & electric power sockets as per instructed by engineer incharge (market rate) 38 item no 37supplying & erecting small size ( approx. 4 6 inch ) outdoor weatherproof junction box for camera rj45 port, dc pin port, camera connectors & audio/alarm i/o port as per instructed by engineer incharge (market rate) 39 item no 38supplying & erecting 1tb internal sata hard drive(market rate) 40 item no 39supplying & erecting 2tb internal sata hard drive(market rate) 41 item no 40supplying & erecting 4tb internal sata hard drive(market rate) 42 item no 41supplying & erecting 6tb internal sata hard drive(market rate) 43 item no 42supplying & erecting 8tb internal sata hard drive(market rate) 44 item no 43supplying & erecting 10tb internal sata hard drive(market rate) 45 item no 44supplying & erecting 6 8ft fabricated angle for camera mounting as per instructed by engineer incharge(market rate) 46 item no 45supplying & erecting 3 4ft fabricated angle for camera mounting as per instructed by engineer incharge(market rate) 47 item no 46supplying & erecting waterproof gel in camerasrj45 jack(market rate) 48 item no 47supplying & erecting core to core fiber splicing(market rate) 49 item no 48supplying & erecting wireless mouse for nvr(market rate) 50 item no 49supplying & erecting 4x4 pvc surface box for camera(market rate) 51 item no 50media converter rack (sanctioned rate) 52 item no 51supplying & erecting 32 inch led tv with wall mounting kit(market rate) 53 item no 52supplying & erecting 43 inch 4k led tv with wall mounting kit(market rate) 54 item no 53supplying & erecting 55 inch 4k led tv with wall mounting kit (market rate) 55 item no 54supplying & erecting wire rope of 3/4/6mm dia. having 6/19 construction as per is complete with termination in provided eye bolts including dismantling of existing accessories. (market rate) 56 item no 55supply and erecting 440v protector with type 2 surge protection for over voltage protection for 1/2 kva ups (market rate) 57 item no 56fabricated battery racks (market rate) 58 item no 57fabricated ups stand (market rate) 59 item no 58connecting & linking cables for ups & batteries (market rate) 60 item no 59256gb memory card (market rate) 61 item no 60supplying and erecting 5m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 22 62 item no 61supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 23 63 item no 62supplying and erecting 15m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 24 64 item no 63supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 25 65 item no 64supplying and erecting 25m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 26 66 item no 65supplying & erecting hdmi extender over rj45 ethernet cable cat 6, 60m/200ft complete.1 8 28 67 item no 66supplying, installing, testing & commissioning of dvi to hdmi convertor highspeed category, supporting full hd 1080p, 2k and 4k video up to 30 ft length, 3d having 24k gold plated 19 pin type a connectors with high flex cl3 rated jacket, rohs compliant complete. dsr 1 8 29 68 item no 67supplying, fixing, and configuring 8 ports managed gigabit, layer 2 switch, 10/100/1000 base t, poe smart switch plus 2 sfp erected in provided rack complete. dsr 1 11 2 69 item no 68supplying, fixing, and configuring 8 ports 1 g unmanaged gigabit poe switch erected in provided rack complete.dsr 1 11 1 70 item no 69supplying and fixing 6u wall mount rack (dimension dxwxh – 500x600x367 mm) as per specification no. wg nas/rak dsr 1 12 17 71 item no 70supplying and fixing 9u wall mount rack (dimension dxwxh – 500x600x500 mm) as per specification no. wg nas/rak dsr 1 12 18 72 item no 71supplying and fixing power distribution unit for networking rack comprises of 6/16a (6 nos. sockets), 25 a modular mcb, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification no. wg nas/rak. dsr 1 12 16 73 item no 72supplying and fixing 1 m utp patch cord of cat 6 type in position as per specification no. wg coc/pc. dsr 1 10 16 74 item no 73supplying and fixing 2 m utp patch cord of cat 6 type in position as per specification no. wg coc/pc. dsr 1 10 18 75 item no 74supplying, fixing, and configuring media convertor 1000 base t to 1000 base sx sc multi mode media. dsr 1 12 38 76 item no 75supplying and installing 3 m fibre patch cord duplex single mode for os1/os2 complete. dsr 1 10 21 77 item no 76supplying and fixing ip66 enclosure for fibre splicing complete. dsr 1 10 29 78 item no 77supplying and fixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided u rack complete as per specification no. wg nas/ liu. dsr 1 12 5 79 item no 78supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided u rack complete as per specification no. wg nas/ liu. dsr 1 12 7 80 item no 79supplying and fixing sc/lc type multimode duplex adapter to couple two connectors between ofc & fibre switch/fibre module as per specification no. wg nas/mma. dsr 1 12 11 81 item no 80supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125µm (os1/os2) 10/40 gbps speed in provided underground hdpe pipe complete. dsr 1 10 9 82 item no 81supplying and installing armoured single mode optical fibre cable with 12 fiber, core dia 50/125µm (os1/os2) 10/40 gbps speed in provided underground hdpe pipe complete. dsr 1 10 10 83 item no 82supplying and installing cat 6 lszh cable suitable for networking as per specification no. wg coc/nc. dsr 1 10 3 84 item no 83supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw. dsr 1 7 11 85 item no 84supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw. dsr 1 3 6 86 item no 85supplying and erecting rigid steel conduit 16 swg 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 1 87 item no 86supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 3 88 item no 87supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 5 89 item no 88supplying and erecting hms pvc conduit frls grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc.dsr 1 1 7 90 item no 89supplying and erecting hms pvc conduit frls grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. dsr 1 1 9 91 item no 90supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. dsr 1 1 11 92 item no 91supplying and erecting pvc trunking (pvc casing n capping) of size 20 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 6 93 item no 92supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 7 94 item no 93supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 8 95 item no 94supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 9 96 item no 95supplying and erecting pvc box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box. dsr 1 2 11 97 item no 96supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. dsr 1 2 13 98 item no 97supplying and installing cat 6 cable with rodent proof and anti termite jacket suitable for networking as per specification no. wg coc/nc. dsr 1 10 6 99 item no 98supplying and installing cat 6 armoured cable with eccs tape suitable for networking as per specification no. wg coc/nc dsr 1 10 7 100 item no 99supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu. dsr 7 2 14 101 item no 100supplying and erecting pole clamp made from 50 x 6 mm ms flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. dsr 8 6 10 102 item no 101supplying and erecting isi mark gi pipe 75/80 mm dia ‘c” class position with accessories complete. specification no. cw plb/gp. dsr 16 5 14 103 item no 102supplying and erecting isi mark gi pipe 50 mm. dia ‘c” class position with accessories complete. specification no. cw plb/gp. dsr 16 5 12 104 item no 103supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete.. dsr 7 6 9 105 item no 104making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr. dsr 16 1 2 106 item no 105supplying, installing & testing utp connector (rj 45) as per specification no. wg nas/utpc as per dsr 1 12 1 107 item no 106supplying and erecting 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. dsr 1 6 45 108 item no 107supplying and erecting pvc surface modular switch box with double mounting plate for 1 module duly erected in an approved manner.dsr 1 6 26 109 item no 108supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected in an approved manner.dsr 1 6 27 110 item no 109supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected in an approved manner.dsr 1 6 28 111 item no 110supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected in an approved manner.dsr 1 6 29 112 item no 111supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected in an approved manner.dsr 1 6 30 113 item no 112supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. dsr 1 6 31 114 item no 113supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. dsr 1 6 32 115 item no 114supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. dsr 1 6 33 116 item no 115supplying and erecting 6 to 32 a, 10ka, spmcb suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. dsr 1 6 44 117 item no 116supplying and erecting 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. . dsr 1 6 45 118 item no 117supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. dsr 1 6 10 119 item no 118supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip. dsr 8 1 16 120 item no 119providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. dsr 8 2 11 121 item no 120providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. dsr 8 2 12 122 item no 121poviding cement concrete foundation including excavation for the poles (45 cm x 45 cm x 120 cm) deep in 1:3:6 cement concrete (20 to 25 mm stone metal) and 45 cm x 45cm x 45 cm / 45 cm dia.x 45 cm height plinth duly plastered and with necesarry curing and finishing in an approved manner (for 6 m pole). dsr 16 3 2 123 item no 122excavating hard rock or bituminous road (b.t.) by chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good. dsr 16 1 5 124 item no 123supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non corrosive bond with required joints as per specification no. ea ep. dsr 9 2 7 125 item no 124providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la. dsr 9 1 6 126 item no 125supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. dsr 9 3 1 127 item no 126supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of 2hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups. dsr 3 7 1 128 item no 127supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of 2hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups 129 item no 128supplying and erecting 12v/100ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete.dsr 3 8 2 130 item no 129supplying and erecting 12v/150ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete. 131 item no 130supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. dsr 1 4 4 132 item no 131 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu. dsr 7 2 15 133 part b. maintenance 134 comprehensive maintenance for second year 135 comprehensive maintenance for third year 136 comprehensive maintenance for fourth year 137 comprehensive maintenance for fifth year ...

Indian Army - Maharashtra

38541565 bids are invited for proc of items for pad shop of ciw beg and centre kirkee mse french polish , glass paint , lime quick , melamine gold glossy , oil bound distemper , paint enamel aluminium , paint enamel brown , paint enamel bus green , paint enamel golden , paint enamel golden brown , paint enamel ox blue , paint enamel po red , paint enamel white , paint lustre white , paint olive green total quantity : 1212...

Rural Development Department - Maharashtra

38515052 supplying electrical materials and repairs maintenance services at. grampanchayat nimgaon, tal. khed, dist. pune , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) , supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying,tpmcb 40a to 63a in provided distribution board , providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) , supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , nut bolt , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , cable joint kit upto 16 sq. mm cable , street light pole box frp , street light pole clamp round type , supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) , servicing and primary maintenance for street light pole.. , light pole painting , 26w led light to 100w led light repairing , old pole shifting , rework and foundation work per pole , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no , supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 , solar battery bracket , solar battery box high quality… , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , distilled water (1 ltr.) , panel frame for old pole , solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. , providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. , supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs , supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) , supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. , supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. , providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep , supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. , dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. , supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. , supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. , supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. , 18 wtt. led bulb , 24 w. led bulb , 30 w. led bulb , supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Department Of Economic Affairs - Maharashtra

38337173 bids are invited for apcolite premium gloss white enamelpaint , apcolite premium gloss bus green paint , apcolite premium gloss black paint , apcolite premium glos golden yellowpaint , apcolite prem.gloss postoffice red paint , g p thinner , black board paint , aluminium paint , touch wood gloss interior wood finish , asian epoxy finish black paint , p s grey primer , d k lac or n c thinner , birla putty powder , red oxide metal primer 1 lpkg , premium emulsion white paint , acrylic distemper white , apex exterior paint apricot illusion7979 , apcolite premium gloss enamel smoke grey , tractor emulsion smooth wall finish , apcolite enamel cascade green 2370 , durocem cement coating brick red total quantity : 2280...

Rural Development Department - Maharashtra

38306106 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Indian Air Force - Maharashtra

38199591 bids are invited for enamel, synthetic, exterior (a) under coating (b) finishing paint (v2) as per is 2932 (q3) , aluminium paint for general purposes in dual container as per is 2339 (q3) mse total quantity : 45...

Directorate Of Municipal Administration - Maharashtra

38198295 tender for rate contract estimate for the day to day electrical work need to carry out for operation and maintenance of ichalkaranji city 1 supplying and erecting rolled steel joist ( girder ) pole 150 x 80 mm / 150 x75 mm ( 14.9 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 2 supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with polecap, base plate in provided foundation as per specification no. oh pl / gip 3 supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with polecap, base plate in provided foundation as per specification no. oh pl / gip 4 supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessaryfittings complete as per specification no. ff pp 5 supplying and erecting g.i. pipe ‘c’ class erw 25 mm dia with necessaryfittings complete as per specification no. ff pp 6 supplying and erecting g.i. pipe ‘c’ class erw 50 mm dia with necessaryfittings complete as per specification no. ff pp 7 supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessaryfittings complete as per specification no. ff pp 8 supplying and erecting g.i. pipe ‘c’ class erw 75 / 80 mm dia with necessary fittings complete as per specification no. ff pp 9 supplying and erecting gate / garden light fitting with 200mm dia. glass bowlsuitable for upto 12w led lamp on provided pipe as per specification no. fg odf / glt 10 supplying and erecting gate / garden light fitting with 300mm dia. glass bowlsuitable for upto 12w led lamp on provided pipe as per specification no. fg odf / glt 11 supplying & erecting integral post top lantern fixtures ( mushroom type ) suitable for led lamp upto 12 w consisting of clear acrylic top cover, castaluminium pole cap complete with accessories on provided pole / bracket as per specification no. fg odf / ptl 12 supplying & erecting integral post top lantern fixtures ( globe type ) suitablefor led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole / bracket as per specification no. fg odf / ptl 13 supplying & erecting integral post top lantern fixtures ( light house type ) suitable upto led 18 w lamp consisting of combination of spun aluminiumcanopy & clear acrylic top cover, cast aluminium pole cap on provided pole / bracket as per specification no. fg odf / ptl 14 supplying and erecting integrated led highbay fitting 70w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min.10000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 15 supplying and erecting integrated led highbay fitting 100w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min. 15000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 16 supplying and erecting integrated led highbay fitting 135w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min. 20000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf / fls2. 17 supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt / bpc 18 supplying and erecting street light bracket for erection of double fittingmade from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt / bpc 19 supplying and erecting street light bracket for erection of single fitting ontubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe alongwith pole cap of 125mm dia 600 mm long duly welded as per specification no.fg bkt / bpc 20 supplying and erecting street light bracket for erection of double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no.fg bkt / bpc 21 supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 22 supplying and erecting electronic type driver for outdoor led fittings 26w 45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 23 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operat 24 supplying and erecting electronic type driver for outdoor led fittings 76w 100w suitable to operate 25 supplying and erecting double pole metal clad switch with hc fuse and neutral link 240v, 16a on iron / gi frame aperspecification no. sw swr / mdp. 26 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / giframe as per specification no. sw swr / mdp . 27 supplying and erecting porcelain base iron clad cut out hc type 415v, 16aerected on polished wooden block. 28 supplying and erecting triple pole metal clad switch and hc type fuse 415v, 16a on iron / gi frame / board perspecification no. sw swr / mtp. 29 supplying and erecting triple pole metal clad switch and fuse 415v, 32a on iron / gi frame as per specification no.sw swr / mtp. 30 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specificationno. sw swr / mtp. 31 supplying and erecting porcelain base iron clad cut out hc type 415v, 32aerected on polished wooden block. 32 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 33 supplying and erecting hc pattern porcelain fuse bridges with base & hc typefuse links 240v, 32a erected on polished wooden block. 34 supplying & erecting fuse bridges with base hc type fuse links 240v, 63aerected on polished wooden block. 35 supplying and erecting isi mark pwd / msedcl make apprved 63*415 vmainswitch action rod 36 remedial action / troubleshuting of supply in occasion of short circuit fault on ovehead line condutor forrestoration of supply in street light or other electrification work by using hydruli platform / manually including changing jumper / sag in line / change shackle, spacer etc. with proior approval of msedcl competant authority 37 providing temporary 2 x 2 / 4 / 6sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required accessories continuous 8 swg g.i. earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary. 38 supplying and erecting integrated led highbay fitting 150w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty 39 supplying and erecting integrated led highbay fitting 200w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 24000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty 40 labour charges & hydraulic vehicle charges for maintainance of tiranga led strip 41 visiting charges for attending fault of electrical equipments / devices, wiring short circuit faults 42 visiting charges for attending fault of air conditioning unit / generator of imc 43 supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 44 supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 45 supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 46 supplying & laying ( including excavation ) reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 47 supplying & laying ( including excavation ) half round reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 48 supplying & laying ( including excavation ) reinforced cement concrete pipe of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc.complete. 49 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 50 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 51 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 52 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 53 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 54 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 55 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 56 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 57 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 58 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 59 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 60 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 70 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 61 re erecting pvc / xlpe armoured cable 2 to 4 core up to 50 sq. mm. on wall with necessary material & g.i. earth wire. 62 supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 63 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 64 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 65 supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 66 supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 67 supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 68 supplying and erecting mains with wp 4 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 69 supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvcinsulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 70 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvcinsulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw 71 supplying and erecting pvc insulated pvc round sheathed 1 sq.mm ( 32 no. x 0.20mm dia. ) 3 core flexible multi stranded copper industrial cable for voltagegrade up to 1.1 kv 72 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 73 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 74 supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 75 supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 76 supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 77 supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 78 supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 79 supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 80 supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 81 supplying, erecting & marking dpmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 82 supplying, erecting & marking tpmcb 6a to 32a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 83 supplying, erecting & marking tpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 84 supplying, erecting & marking fpmcb 6a to 32a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 85 supplying, erecting & marking fpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 86 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 87 supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 88 supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 89 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 90 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 91 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom ism channel 75x40x6mm and 550mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 92 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 93 supplying & erecting ms pole bracket for lt oh conductor fabricated from65x65x6 mm section, 550mm long for necessary nos. of provided insulatorsand erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 94 supplying & erecting ms pole bracket for lt oh conductor fabricated from65x65x6 mm section, 1100mm long for necessary nos. of provided insulatorsand erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 95 supplying and erecting all aluminium stranded conductors 7 / 2.21complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 96 supplying and erecting all aluminium stranded conductors 7 / 3.10 complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 97 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 98 supplying and erecting aluminium bobbin with g.l. ( shackle ) strip, nuts complete. 99 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7 / 10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete. 100 supplying and erecting g.i. wall hook, 10 to 15mm dia and overall length 250mm including grouting, cement plastering etc. complete. 101 supplying and erecting guarding loop using g.l. wire no. 8 swg for lt oh line of horizontal formation erected with 20swg g.l. wire as binding wire and 50mm section on each side complete. 102 supplying and erecting pole clamp made from 50 x 10mm ms flat for pole or pipe, post complete erected with 15mm bolts and nuts, complete duly painted with one coat of redoxide and two coats of aluminium paint. 103 supplying and fixing ms base plate 30x30x0.6 cm size fixed to the pole base either by welding or by set screws 12mm. dia fixed at position. 104 dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level 105 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concretefoundation and making the site clear by refilling the pitswith excavated materials and bringing it to the ground level. 106 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 107 dismantling the existing lightning arrestor set, insulator from dp structure complete. 108 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 109 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep 110 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 111 providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep 112 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification noea ep. 113 supplying and erecting gi wire of high purity of required sizes used for earthingor any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws complete. 114 making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( for 6 m pole ) 115 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) 116 making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) 117 making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. ( cost of wooden box is included ) ( for pumps ) . 118 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 119 making cement concrete foundation in 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing for complete. ( pole muffing or any other purpose ) . 120 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 121 making m 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 122 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal / conical gi pole ) . 123 supplying and erecting gi sheet 1.25 mm ( 18 swg ) having zinc coating of350 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2coats of enamel paint. 124 supplying and erecting marine ( waterproof ) plywood 18 / 19 mm thick fixed towall or on provided panel board with necessary materials such as screws, wallfasteners, supports, nut bolts etc. complete with compliance to is 720:2010 125 supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 126 supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority 127 supplying and erecting static energy meter with 240v 50 hz. ac supply 5 to 30 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display kwh, kvah, v, i, pf, frequency, kw, kva, six months history of energy & md in kw & kva ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. 128 supplying and erecting static energy meter with 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display kwh, kvah, v, i, pf, frequency, kw, kva, six months history of energy & md in kw & kva ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. 129 supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw ) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company 130 supplying and erecting static energy trivector meter 440 v 50 hz. 20 100a isi mark meter ac 3 phase 4 wires lcd / led display ( measuring and display trivector, v, i, kw, pf, hz, last month history of kwh & md in kw ) with special features like tod, tamper logging, optical communication port & display in absence of power complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested for class 1.0 accuracy by electric supply company. 131 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as perspecification no. cb jt / lt 132 providing & erecting epoxy straight through joint outdoor / indoor for ltxlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt / lt 133 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt / lt 134 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as perspecification no. cb jt / lt 135 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 300 sq mm., with necessary material as per specificationno. cb jt / lt 136 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt / lt 137 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 25 to 50 sq.mm. cable, with necessary material as per specification no.cb jt / lt 138 providing & erecting epoxy outdoor / indoor end termination kit for ltxlpe armoured cable 70 to 120 sq mm., with necessary material as perspecification no. cb jt / lt 139 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 150 to 185 sq.mm. cable, with necessary material as per specification no.cb jt / lt 140 providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as perspecification no. cb jt / ht 141 providing and erecting heat shrinkable outdoor termination kit for 11 kv ( e ) xlpe ht cable 3x120 to 185 sq. mm. with necessary material as per specification no. cb jt / ht 142 providing and erecting heat shrinkable out door termination kit for 11 kv ( e ) xlpe ht cable 3 x up to 95 sq. mm. with necessary material as perspecification no. cb jt / ht 143 supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kva capacity online pure sine wave ups, with backup time of .......hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups 144 supplying, erecting, testing and commissioning of 2kva capacity online puresine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 145 supplying, erecting, testing and commissioning of 3kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 146 supplying, erecting, testing and commissioning of 6kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 147 supplying, erecting, testing and commissioning of 10kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 148 supplying and erecting 12v / 80ah to 88ah tubular battery with battery terminalwire, duly charged with 36 months warranty complete. 149 supplying and erecting 12v / 100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 150 supplying and erecting 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 151 supplying and erecting 12v / 180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 152 supplying and erecting 12v / 200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 153 supplying and erecting 12 v / 65ah smf battery with battery terminal wire, dulycharged complete with 24 months warranty complete 154 supplying and erecting 12v / 100ah smf battery with battery terminal wire, dulycharged with 24 months warranty complete. 155 supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “on” and switching“off” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit led continuous time display, relay output 230 v / 10a with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided m.s. box. 156 supplying and erecting four pole power contactor 430 v, 16 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 157 supplying and erecting two pole power contactor 230 v, 32 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 158 supplying and erecting four pole power contactor 430 v, 40 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 159 painting of pipe pole up to 6 m length along with street light / polebrackets / clamps etc by scrapping the existing paint complete as perspecification no cw ptg / ptp. 160 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp 161 powder coating of approved colour shade on both sides of provided iron work / ms / crca sheet steel work complete including anti rust treatment complete. 162 epoxy painting on both side of approved colour shade of provided iron work / ms / crca sheet steel work complete along with anti rust treatment complete. 163 supply and erection of new pole erection / shifting pole or overhead / underground cables msedcl quotation under 1.3% ddf scheme ( incl tech. sanction+supervision charges ) ...

Rural Development Department - Maharashtra

38109646 providing electrical material and services l at grampanchayat ranjangaon ganpati , material list , supplying pre stressed cement concrete (psc) rectangular pole of top 90 x 102 / 105 mm & bottom of 90 x 275 mm 8 m long (140 kg) complete erected in provided c. c. foundation & muffing (square / round) , supplying ms pole bracket, fabricated from ism channel, 75x40x6mm, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length and erecting on pole with 50x6 mm clamp as per approved method of construction , supplying ms pole bracket, for oh conductor fabricated from ism channel, 75x40x6mm 550mm long for 2 insulators and erecting on pole with 50x6 mm clamp as per approved method of construction , supplying all aluminium stranded conductors 7/2.21 mm complete. (gnat) (73.77kg/km) , supplying porcelain shackle type lt medium insulator 50 x 89 mm dia. with g.i. (shackle) strips, nuts and bolts, , supplying pole clamp made from 50 x 10 mm ms flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coatsof aluminium paint. , supplying g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7/8 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. , dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materialsand bringing it to the ground level. , g.i pipe , 8 mtr ms pole , ab cable 16 sqmm , ab cable 25sqmm , ab cable 35sqmm , ab cable 50sqmm , ab cable 70sqmm , ab cable 95 sqmm , ab cable 120 sqmm , 40w led street light , 70w led street light , 100w led street light , 100 w led flood light , 150 w led flood light , connector / junction box...

Rural Development Department - Maharashtra

38064200 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Central Railway - Maharashtra

38021864 supply of paints, enamel synthetic exterior brushing / finishing golden yellow to isc:356 and conforming to icf / md / spec 045 issue status 02 rev. 03 and is:8662 2004 ( reaffirmed 2019 ) except clause c3 along with rdso amdt. no.1a ( rev. 1.0 ) . packing in 20 ltrs new non returnable m.s. drums to is:2552 1989 ( reaffirmed 2018 ) , gr. b2. [ warranty period: 12 months after the date of delivery ] , enamel synthetic exterior brushing / finishing white to icf / md / spec. 045 issue status 02 rev.03 and is:8662 2004 ( reaffirmed 2019 ) except clause c3 along with rdso amdt. no.1a ( rev. 1.0 ) . packing in 20 ltrs. new non returnable m.s. drums to is:2552 1989 ( reaffirmed 2018 ) , gr. b2. [ warranty period: 12 months after the date of delivery ] , aluminium paint brushing, bright finishing for general purpose to is: 2339 / 2013 ( reaffirmed 2018 ) and rdso amdt no.1a rev 1.0 as an additional requirement. packing in 4 ltrs. dual container ( alluminium paste packed in polyurethane bags and dipped in 4 ltrs. containers ) . [ warranty period: 12 months after the date of delivery ] ...

Rural Development Department - Maharashtra

38003871 supplying electrical materials and repairs maintenance services at. grampanchayat wasuli, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38002584 supplying electrical materials and repairs maintenance services at. grampanchayat sawardari, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying,tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l/t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker (1 hours) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water (1 ltr.) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac 59 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 60 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 65 supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. ...

Rural Development Department - Maharashtra

37787460 supply of various items for gram panchayat aalegaon tq. kandhar dist. nanded , ) machine ( strachu meter ) =03 ? ) cooker ( pressure cooker 9 ltr = 03 ) chair ( baby chair ) = 75 ? ) machine ( weight machine ) = 03 , led ) led street light ( 36 watt ) ( osaram 36 watt ( ip 65 water proof ) luminary aluminum dicast body street light bracket as per csr 1.5 sqmm 4 core cable of isi mark 14 mtr. installation of street light. dpmcb 40 a to 63 a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb pole clamp made from 50x10 mm ms flat for pole or pipe, post complete duly painted with one coat of red oxide and twocoats of aluminum paint. = 07 , ? ) stand ( shoe stand ) = 03 ? ) rack ( anganwadi pot rack ) = 03 ? ) kothaya ( dhanya kothaya 100 kg ) = 06 ? ) table ( office table 2×3 ) = 03 , led street light ( 36 watt ) ( osaram 36 watt ( ip 65 water proof ) luminary aluminum dicast body street light bracket as per csr 1.5 sqmm 4 core cable of isi mark 14 mtr. installation of street light. dpmcb 40 a to 63 a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb pole clamp made from 50x10 mm ms flat for pole or pipe, post complete duly painted with one coat of red oxide and twocoats of aluminum paint. ? ) = 16...

Directorate Of Municipal Administration - Maharashtra

37745599 matheran electrical material supply , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning 11kv hrc fuse 10a to 40a for load break switch with necessary nut bolts complete. , supplying, installing, testing and commissioning 11 kv hrc fuse 63a for load break switch with necessary nut bolts complete. , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap ac/wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7tr to 0.9tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning ip epabx for 10 extensions complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 6 x 16 extension complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 3 x 8 extensions complete. , supplying, installing, testing & commissioning analogue type epabx of 3 x 8 extension complete. , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 2280 to 2850lpm at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 45kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 1600 to 1800 lpm at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 30kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning 3 phase, 22/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°c at ambient temp max 50°c & min 5°c at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage & frequency (+15% is tol) 1.80 kw, full load loss at rated current 3.00 kw, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 23 degree of protection, cable box arrangement at hv side & bus duct at lv side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & wti scanner with 3 pt 100 sensors, etc. standard accessories complete with test certificate (as per is:11171 & iec 60076 11) with necessary permissions of electrical inspector, as per specification no. ss tr. , supplying, installation, testing and commissioning 3 phase, 11/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oc at ambient temp max 50oc and min 50oc at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage and frequency (+15% is toi) 1 kw, full load loss at rated current 3.15 kw, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 21 degree of protection, cable box arrangement at hv side and bus duct at lv side, with rating and diagram plate, base channel, earthing terminals and wti scanner with 3 pt 100 sensors, etc., standard accessories complete with test certificates (as per is:11171 & is 2026) with necessary permissions of electrical inspector as per specification no. ss tr. , supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results specification no. ea mobi , supplying, fixing, and configuring modularised multi service router 802.11/a/n/ac unified wave 2.5 ghz, with rj 45 port, supporting 1 to 13 channels for 2.4 ghz, with unified wireless access point complete , supplying, fixing, and configuring 24 ports with 4 (sfp+) port, ethernet managed switch with web view/cli, 6kv surge protection on ethernet port and console port for management in provided rack as per specification no. wgnwc/gbs , supplying, fixing, and configuring 24 ports + 4 (sfp+) port, managed layer 2, poe switch of , 370w, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing, and configuring 20 sfp ports + 4 combo sfp 10/100/1000 base t erected in provided rack complete. , supplying, fixing, and configuring 20 (1g rj45) ports + 4 combo 1g ports + 4 10g (sfp+) ports, layer 3 switch, si image, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr / mcbcos , supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of ....... hrs. pwm & igbt based, with 0.8 to unity output pf complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 82.5 kva up to 100 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 62.5 kva up to 82.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 50 kva up to 62.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 40 kva up to 50 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 35 kva up to 40 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 25 kva up to 35 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 20 kva up to 25 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 15 kva up to 20 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 125 kva up to 140 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 100 kva up to 125 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 10 kva up to 15 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of diesel generating set with standard control panel with alternator of 5 kva continuous rating, single phase, 230v, 50c/s 0.8 p. f. ac supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self excited, selfregulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 1.3 ltr/hr @75% loading. engine and alternator directly coupled on a common fabricated steel base plate with anti vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. the complete set enclosed in acoustic enclosure made of 18 swg crca sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 db at 1.0 m. the engine with first filling of oil, diesel not less than 13 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 14.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 145 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 11.3 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 9.98 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 7.47 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.9 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 34.40 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db(a) at 1.0 m, provided with first filling of oil, diesel not less than 300 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.8 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 50 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 17.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 2.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of 6kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 3kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 28hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 20hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56°c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 12hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 6a to 32a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & commissioning mdf box 600x600 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 500x500 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 400x400 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 300x300 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 250x250 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 200x200 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 150x150 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 100x100 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 100a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying table fan of a.c. 230 v. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and hand shield type 3 pin plug top. , supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying led concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4w 6w led including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. , supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 star inverter type, stabilizer free operation suitable for operation on 100v/300 v, 50hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. , supplying and plugging 3 m fibre patch cord lc sc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc sc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and laying rigid steel conduit 16 swg 32 mm dia. with necessary accessories in rcc work/false ceiling/false flooring as per specification no: wgma/cc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and installing, testing & commissioning of digital (hybrid) type epabx of 6 x 32 extensions suitable upto 96 extensions complete. , supplying and fixing wireless n 150 desktop adapter in provided computer as per specification no. wg nas/lanc2 , supplying and erecting vpit heavy duty copper wound ballast 230v for 80 150w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting vpit compound heavy duty copper wound ballast for 230v for 250w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system. , supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) , supplying and erecting two pole power contactor 230 v, 32 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole metal clad changeover switch 240 v, 32 a erected on angle iron/gi frame and duly connected with suitable wire leads complete , supplying and erecting triple pole mini feeder pillar with 500v, 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a with aluminium bus bar erected in 14 swg crca sheet box with supporting angles, self locks, gasket having ip54,ik10 protection and slanting top to be erected on provided foundation complete as per specification no. sw , supplying and erecting t8 fluorescent tube day light 1200mm, 36 w , supplying and erecting t5 24 w energy efficient fluorescent tube. , supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt/bpc , supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.ap wh/stwh , supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kwh / 24 hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 2 ways (2 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 10 ways (10 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting shockproof t. switch 16 a porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof piano type switch 250 v, 16 a, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (trs type) pvc insulated copper wire of size 0.5 sq mm 5 m length connected to the point. , supplying and erecting shockproof 6a porcelain base t.switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected , supplying and erecting shockproof 3 pin plug socket 6a with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof 3 pin plug socket 16a with porcelain base/ flush type erected on filled polypropylene (is:14772 2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting rectangular shaped led panel light(1200mm x 300mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6a erected on m.s box made of 16 swg sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6 a combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor. , supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con , supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected , supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 1 module complete duly erected. , supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. , supplying and erecting pvc surface modular double mounting plate 8 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 6 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 4 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 3 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 2 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 16/18 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 12 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 1 module complete duly erected. , supplying and erecting pvc slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. , supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box . , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. , supplying and erecting porcelain base iron clad cut out hc type 415v, 63a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 32a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 200a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 16a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 100a erected on polished wooden block. , supplying and erecting pole clamp made from 50x6mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting pole clamp made from 50x10mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 63a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, , ip 54 and ik10 protection, 45 a tp contactor for automatic switching of luminaires, 2 no 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 32a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, ip 54 and ik10 protection, 25 a tp contactor for automatic switching of luminaires, 2 no. 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting one/two way piano type switch 6a./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting modular type two way switch 6a / 10a (2 module), duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch one way 16 / 20 a, duly erected on provided plate and box with wiring connections complete with neon indicator. , supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch 16a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type buzzer 220 / 250v, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type blanking plate two module, duly erected on provided plate & box , supplying and erecting modular type bell push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell push 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 6 / 16a fuse unit, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections , supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 600/650w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 1000w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (one module) electronic dimmer 400 / 450w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete , supplying and erecting metal halide lamp double ended 230v, 70 w . , supplying and erecting metal halide lamp double ended 230v, 250 w. , supplying and erecting metal halide lamp double ended 230v, 150 w . , supplying and erecting marine (waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to is 720:2010 , supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with 4x25 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 2x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230v a.c. supply with resetting arrangement complete erected on double wooden/ sunmica board. , supplying and erecting lszh armoured multimode optical fibre cable with 6 fibres, core dia 50/125 ?m (om4) suitable up to 10 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. wg coc/ofc , supplying and erecting led strip light 5m length max. 95 w ip20 class having minimum lumens output of 1600 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50 including driver with 1 year warranty. , supplying and erecting led strip light 5m length max. 45 w ip20 class having minimum lumens output of 800 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50, including driver with 1 year warranty. , supplying and erecting led square / circular max. 7w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led square / circular max. 25 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 18 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led panel light(600mm x 600mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg , supplying and erecting integrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf/fls2. , supplying and erecting integrated led street light fitting 120w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led post top 45w ip65 & ik10 class having die cast aluminium housing with uv protected polycarbonate diffuser, having system lumens output of min.4500 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 30,000 hrs. at l50b50 , including driver complete with 2 year warranty as per specification no fgodf/fls , supplying and erecting integrated led highbay fitting 135w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50,000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 70w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 8400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 5000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 30w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 3000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 195w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 23400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 155w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 18600 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 120w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min.14500 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 800mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 500mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting ignitor suitable for 230v hpsv lamp 70/150/250/400w as specification no. fg fg/as6 , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 70 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head / pin type 230v, 70 w son type. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma/con. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall /ceiling as per specification no: wg ma/con. , supplying and erecting gi wire of high purity of required sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete. , supplying and erecting gi strip of high purity required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint with joints required. as per specification no ea ep. , supplying and erecting gi sheet 0.8 mm (22 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gi sheet 0.6 mm (24 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12w led lamp on provided pipe as per specification no. fg , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, g.l. stay wire 7/8 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop insulator, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable ms clamps duly erected in provided c.c. foundations complete. , supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting g.i. pipe ‘c’ class erw 75/80 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15m long) with pole clamp, made of 50x6mm ms flat, erected on provided rsj pole complete. (add. rs. 25/ per m for extra length beyond 15 m) , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for, 1kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top suitable for with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 4kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting four pole power contactor 430 v, 16 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting flush, shock proof plug socket 6 pin 6a and 16a with switch 16a combined unit erected in recess in 16 gauge m.s sheet box duly painted and connected with earth terminal and leads , supplying and erecting flush type, shockproof plug socket 6 pin 6a and 16a with switch 16a combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with s m screws and duly connected. , supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. , supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. , supplying and erecting exhaust fan heavy duty 230 v, a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 1400 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg , supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn/cf , supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of 28w having service ratio (cmm/w) of min. 8 , pf>0.9, thd , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 76w100w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th , supplying and erecting electronic type driver for outdoor led fittings 46w75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<1 , supplying and erecting electronic type driver for outdoor led fittings 26w45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and , supplying and erecting electronic type driver for outdoor led fittings 151w200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 101w150w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd , supplying and erecting electronic ignitor suitable for 230v metal halide lamp 70/150/250/400w (integral or non integral type luminaires as specification no. fg fg/as6 , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. , supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. as per specification no. eaep. , supplying and erecting control gear for non integral flood light fittings suitable for 2x250w hpsv/mh lamp with all accessories complete. , supplying and erecting control gear for non integral flood light fittings suitable for 1x400w hpsv/mh lamp with all accessories complete. , supplying and erecting condenser for mv/sv/mh lamp 250w,230v as specification no. fg fg/as7 , supplying and erecting condenser for mv/sv/mh lamp 150w,230v as per specification no. fg fg/as7 , supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting c type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting c type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. , supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no ea ep. , supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles a.c. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting acrylic sheet 3 mm thick to be used for covering the crca sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete. , supplying and erecting 75 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 50 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 40 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 30 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 570 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries) , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries , supplying and erecting 12v/80ah to 88ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/7ah 7.5ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/42ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/26ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/17ah 18ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/130ah to 135ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. , supplying and erecting 12.5 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/hm (excluding luminaries , supplying and erecting 12 v/65ah smf battery with battery terminal wire, duly charged complete with 24 months warranty complete , supplying and erecting 11 kv outdoor type gang operated air break, triple pole switch 200 a capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of c class g.l. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground level with necessary clamp. , supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 100 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting ‘d’ type pole clamps, fabricated from 50x6mm ms flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12 exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12 exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(e), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating 11 kv(e), 3 x 70 sq. mm., aluminium conductor xlpe insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. cb ht , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300 x 200 x 150 mm complete on pole as per specification no. cb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 150 x 100 x 100 mm complete on pole as per specification no. cb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 , supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting three phase, 415v, street light control panel up to the max load of 12kw, tpn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 4 pole contactor up to 60a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 2 pole contactor up to 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting single pole cut point channel set of for 11kv ht oh line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. , supplying & erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ cc foundation. , supplying & erecting single phase, 240v, street light control panel up to the max load of 12kw, spn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting single compression type brass cable glands for 4 core 35 sq.mm./3 core 50 sq.mm. for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying & erecting ms pole bracket for lt oh conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 2.25 kw/3 hp with discharge 600/110 litres per minute (lpm) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 1.5 kw/2 hp with discharge 600/140 litres per minute (lpm) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 5.625 kw/7.5 hp with discharge of 780/170 litres per minute (lpm) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 3.75 kw/5 hp with discharge 715/200 litres per minute (lpm) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 230v, single phase 50 cycles a.c. supply of 1.125 kw/1.5hp with discharge 198/50 litres per minute (lpm)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (light house type) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (globe type) suitable for led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. fg , supplying & erecting inline d.p. structure for 11/0.415kv, 63kva transformer with rsj pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of crca sheet 16 swg with 4 pole mccb 100a as incomer & 6 nos. 63a kitkat/mccb for outing circuits. transformer d.p. structure includes the a.b. switch 200a, d.o. fuse set & l.a. set. 2 nos. top channel of size 100x50mm for erection of a.b. switch & 2 nos. base channel of size 100x50mm for erecting transformer channel of size 75x40mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 200 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 300 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete , supplying & erecting g.i. pipe ‘a’ class 75 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting fully automatic star/delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. , supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting four pole on load change over switch, 415v, 63a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 40a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 32a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3 . , supplying & erecting four pole on load change over switch, 415v, 315 320a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 200a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 160a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 100a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 10 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 h.p. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 h.p. , supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 h.p. , supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification no. cb cl/al , supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 30 a, 3 pin plug & earth socket and 30a, 3 pin plug top with 30a triple pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron / gi frame. , supplying & erecting co axial copper cable low voltage grade tri shielded rg11 as per specification no. wg tw , supplying & erecting co axial copper cable low voltage grade tri shielded rg , supplying & erecting cast iron cable indicator plate buried along with route of cable for pvc / xlpe armoured cable as per specification no. cb cip , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 hp consisting of star delta starter having relay range 9 14 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 15 hp consisting of star delta starter having relay range 13 22 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e , supplying & erecting 14w, 230v integral type led lamp suitable for b 22 / e27 base. , supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. , supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 0.5 mm dia, copper jumper wire as per specification no. wg tw , supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. , supply and erecting 9m (clear height) fixed type high mast (top 100mm, bottom 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. oh pl/opl (excluding luminaires). , rewinding the motor of the exhaust fan 900 / 1400 rpm 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year , rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. , rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for original speed and consumption with guarantee for 1 year including transportation from site and back , rewinding of electric motor upto 1 h.p. single phase up to 1400 rpm of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year. , rewinding of electric motor up to 1 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 7.5 h.p. upto 10 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea , rewinding of electric motor above 5 h.p. upto 7.5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 3 h.p.upto 5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 2 h.p. upto 3 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 1 hp upto 2 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. , providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep , providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 kilogram). , providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as per specification no. cb jt/ht , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 400 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 300 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 200 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 150 mm width & 100 mm height comprising all required standard accessories , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 8 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no sw swr/mccbpb. (excluding mccbs) , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 12 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no. sw swr/mccbpb. (excluding mccbs) , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as per specification no. cb jt/lt , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure/panel as per specification no. sw swr/mccb , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. oh pl/opl , point wiring in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/fan/bell in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire with flush type switch and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/cw , point wiring for independent plug, concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/c , point wiring for ceiling fan (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw/hw , making trench in soft soil having 0.9m depth and minimum 0.3 m width as per is for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. external surface duly plastered by 12 mm thick including watering etc complete , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). , excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. , concealing of provided g.i. pipe/h.g. screwed conduit/pvc pipe in wall/floor/false ceiling complete as per specification no:wg pw/cw , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole)....

Department Of Atomic Energy - Maharashtra

37741224 bids are invited for aluminium paint, heat resistant is:13183 (q3) , enamel, synthetic, exterior: (a) under coating (b) finishing paint is:2932 (version 2.0) (q3) total quantity : 110...

Private Company - Maharashtra

37686885 auction sale of various scrap materials 1 easy clean emulsion 179.7 25000 na 2 prolink luxol enamel 20 3 all guard, longlife & easy clean emulsion 72 4 aluminium paints 55.95 5 bison emulsion 141.8 6 butterfly & jadoo 20 7 butterfly enamel 610.2 8 colorant & stainers 4.188646 9 construction chemical products 484.5 10 distemper 296 11 easy clean emulsion 14.4 12 epilux & industrial 1465 13 exteriror texture 60 14 extrier texture 960 15 floor coatings 214 16 home sheld 576 17 industrial liquid 4121.79 18 industrial primer 220 19 luxol emulsion 4 20 luxol enamel 625.48 21 luxol xtraenamel 28.5 22 powder coating material 49.5 23 primer 26 24 primer s/t 40 25 primer w/t 8 26 prolink emulsion 220 27 putty & duracem 5840 28 rangoli emulsion 158.4 29 rangoli emulsions 34.2 30 red oxide primer 848 31 satin enamel 8 32 silk emulsiom 72 33 silk emulsion 58.5 34 silk illusion metallic 24 35 thinners 310 36 tools 13 37 universal colorant 0.0616 38 walmasta emulsion 321 39 water base enamel 99 40 weather coat flexo 34.4 41 weather coat emulsion 1081.6 42 wood coating 193.44 43 wood keeper/coatings 1209.8 44 wood stainer 95 luxol hi gloss cols satin blue 4 l luxol enamel l 4 13 13 52 52 luxol hi gloss cols lime frost 4 l luxol enamel l 4 1 1 4 4 luxol hi gloss cols aquamarine 4 l luxol enamel l 4 6 6 24 24 luxol hi gloss cols off white 4 l luxol enamel l 4 2 2 8 8 luxol hi gloss cols royal ivory 4 l luxol enamel l 4 8 8 32 32 luxol hi gloss cols brown 4 l luxol enamel l 4 1 1 4 4 luxol hi gloss cols gldn brown 1 l luxol enamel l 1 10 10 10 10 luxol hi gloss cols signal red 4 l luxol enamel l 4 2 2 8 8 luxol hi gloss cols signal red 20 l luxol enamel l 20 1 1 20 20 luxol hi gloss syn enamel dawn 4 l luxol enamel l 4 8 8 32 32 luxol hi gloss cols smoke grey 20 l luxol enamel l 20 1 1 20 20 luxol hi gloss cols black 500 ml luxol enamel ml 0.5 4 4 2 2 luxol hi gloss cols mahogany 4 l luxol enamel l 4 2 2 8 8 butterfly gp syn enamel white 20 l butterfly enamel l 20 2 2 40 40 butterfly gp syn enamel phiroza bl 500 ml butterfly enamel ml 0.5 3 3 1.5 1.5 butterfly gp syn enamel phiroza bl 4 l butterfly enamel l 4 12 12 48 48 butterfly gp syn enamel phiroza bl 20 l butterfly enamel l 20 3 3 60 60 butterfly gp syn enamel oxford blu 4 l butterfly enamel l 4 1 1 4 4 butterfly gp syn enamel bus green 4 l butterfly enamel l 4 6 6 24 24 butterfly gp syn enamel mint green 20 l butterfly enamel l 20 2 2 40 40 butterfly gp syn enamel golden ylw 4 l butterfly enamel l 4 2 2 8 8 butterfly gp syn enamel golden ylw 20 l butterfly enamel l 20 1 1 20 20 butterfly gp syn enamel gldn brown 4 l butterfly enamel l 4 2 2 8 8 butterfly gp syn enamel deep ornge 20 l butterfly enamel l 20 1 1 20 20 butterfly gp syn enamel deep ornge 20 l butterfly enamel l 20 2 2 40 40 butterfly gp syn enamel light grey 500 ml butterfly enamel ml 0.5 80 80 40 40 butterfly gp syn enamel light grey 1 l butterfly enamel l 1 17 17 17 17 butterfly gp syn enamel smoke grey 20 l butterfly enamel l 20 1 1 20 20 ...

Rural Development Department - Maharashtra

37669228 supply material for annual construction grampanchayat chicholi year 2023 24 , sand bhandara , sand local kanhan river , soft murum , metal 80 mm , metal 40 mm , metal 20 mm , metal 6 mm , bricks table sample (red) , opc cement isi mark , ppc cement isi mark , dust , steel 20 mm , steel 16 mm , steel 12 mm , steel 10 mm , steel 8 mm , steel 6 mm , kota stone , submershible pump 7.5 hp , submershible pump5 hp , submershible pump3 hp , submershible pump1 hp , lead 8 mm , rcc benchess , hard murum , pelving block hydrolick mode , pelving block rubber mode , cement pipe 300 mm , cement pipe 450 mm , cement pipe 600 mm , cement pipe 900 mm , mixer machin , vibrator , water tanker , road roller , centring plat , khille , centring tar , tree gard zaliwala 5 fut , bricks table sample (cement) , covering block , cheker tiles (cement) , cheker vetrified tiles , cerimice tiles , koda , wall tiles , floor tiles , greynite , green marble , kadapa , naylon rassi , quring panni , naryal rassi , centring nail , ancore bord , pawda , tikas , sabble , pvc ghamela , steel ghamela , 14 inch steel cutting blade , 4 inch steel cutting blade , steel frame , steel ralling , steel chaddar , steel window , cement window , profile sheet , gi sheet , pvc sheet , m/s pipe , concrete cheker , lw plus liquid , urp liquid , water proof pawder , groute powder , crake seal , mseal , obd distemper , weather cote paint , cement colour , birla white cement , eagle cem , snow cem water proof cement paint , chhuna , pop powder , cement pipe 150 mm , red oxide primer , tarpin oil , stainer , sine paper , oil primer , alluminium paint , glass putty , wall putty , roller brush , painting brush , zaddu brush , rubber paint , screw , door kit , acid , fenile , bleeching powder , casting soda , rassa , garden pipe , handle , chember , hdpe pipe , green net , kharata , jali , trilpal , chenling jali , kata tar , cement pol , doors , alluminium door , glass mirror , plywood sheet , sandas sit , murga , jents urinal , section pipe , puc pipe 160 mm 6 kg , puc pipe 160 mm 4 kg , puc pipe 140 mm 6kg , puc pipe 140 mm 4kg , puc pipe 110 mm 6kg , puc pipe 110 mm 4kg , pvc pipe 90 mm 6kg , pvc pipe 75 mm 4kg , pvc pipe 63 mm 4kg , pvc pipe 90 mm4 kg , pvc pipe 75 mm 6kg , pvc pipe 63 mm 6kg , pvc socket , pvc bend , pvc elbo , pvc tee , gi pipe90 mm , gi pipe 63 mm , gi pipe 50 mm , gi bend 90 mm , gi bend 63 mm , gi elbo 90 mm , gi elbo 63 mm , air wall , dack foot bend , c i raod way , maitaincoupling 90 mm , maitaincoupling 110 mm , maitaincoupling 160 mm , maitaincoupling 200 mm , maitaincoupling 63 mm , maitaincoupling 75 mm , cid joind , cid mechanical joind , non return valve 80 mm , cpuc pipi , cpuc socket , cpuc elbo , cpuc tee , belcha heavy , puc reducer , pvc tellpease plus flanch , c.i. flanch , pvc cid coplar , solvent solution , ladies urinal , wash basinig , ms steel sine bord with painting , walmasta paint , loxol oil paint , alluminium sliding window , bision emulsion , febrication tin sheet , febrication grill work , jcb...

Rural Development Department - Maharashtra

37651626 supply material for annual construction grampanchayat nanadevi year 2023 24 , sand bhandara , sand local kanhan river , soft murum , metal 80 mm , metal 40 mm , metal 20 mm , metal 6 mm , bricks table sample ( red ) , opc cement isi mark , ppc cement isi mark , dust , steel 20 mm , steel 16 mm , steel 12 mm , steel 10 mm , steel 8 mm , steel 6 mm , kota stone , submershible pump 7.5 hp , submershible pump5 hp , submershible pump3 hp , submershible pump1 hp , lead 8 mm , rcc benchess , hard murum , pelving block hydrolick mode , pelving block rubber mode , cement pipe 300 mm , cement pipe 450 mm , cement pipe 600 mm , cement pipe 900 mm , mixer machin , vibrator , water tanker , road roller , centring plat , khille , centring tar , tree gard zaliwala 5 fut , bricks table sample ( cement ) , covering block , cheker tiles ( cement ) , cheker vetrified tiles , cerimice tiles , koda , wall tiles , floor tiles , greynite , green marble , kadapa , naylon rassi , quring panni , naryal rassi , centring nail , ancore bord , pawda , tikas , sabble , pvc ghamela , steel ghamela , 14 inch steel cutting blade , 4 inch steel cutting blade , steel frame , steel ralling , steel chaddar , steel window , cement window , profile sheet , gi sheet , pvc sheet , m / s pipe , concrete cheker , lw plus liquid , urp liquid , water proof pawder , groute powder , crake seal , mseal , obd distemper , weather cote paint , cement colour , birla white cement , eagle cem , snow cem water proof cement paint , chhuna , pop powder , cement pipe 150 mm , red oxide primer , tarpin oil , stainer , sine paper , oil primer , alluminium paint , glass putty , wall putty , roller brush , painting brush , zaddu brush , rubber paint , screw , door kit , acid , fenile , bleeching powder , casting soda , rassa , garden pipe , handle , chember , hdpe pipe , green net , kharata , jali , trilpal , chenling jali , kata tar , cement pol , doors , alluminium door , glass mirror , plywood sheet , sandas sit , murga , jents urinal , section pipe , puc pipe 160 mm 6 kg , puc pipe 160 mm 4 kg , puc pipe 140 mm 6kg , puc pipe 140 mm 4kg , puc pipe 110 mm 6kg , puc pipe 110 mm 4kg , pvc pipe 90 mm 6kg , pvc pipe 75 mm 4kg , pvc pipe 63 mm 4kg , pvc pipe 90 mm4 kg , pvc pipe 75 mm 6kg , pvc pipe 63 mm 6kg , pvc socket , pvc bend , pvc elbo , pvc tee , gi pipe90 mm , gi pipe 63 mm , gi pipe 50 mm , gi bend 90 mm , gi bend 63 mm , gi elbo 90 mm , gi elbo 63 mm , air wall , dack foot bend , c i raod way , maitaincoupling 90 mm , maitaincoupling 110 mm , maitaincoupling 160 mm , maitaincoupling 200 mm , maitaincoupling 63 mm , maitaincoupling 75 mm , cid joind , cid mechanical joind , non return valve 80 mm , cpuc pipi , cpuc socket , cpuc elbo , cpuc tee , belcha heavy , puc reducer , pvc tellpease plus flanch , c.i. flanch , pvc cid coplar , solvent solution , ladies urinal , wash basinig , ms steel sine bord with painting , walmasta paint , loxol oil paint , alluminium sliding window , bision emulsion , febrication tin sheet , febrication grill work , jcb...

Kolhapur Municipal Corporation - Maharashtra

37615124 tender for all type hardware, vehicle kushan material, glass material, all type color, nut bolt, jack, spanner, tools, cotton west etc. supply 1 lokhandi patra 8x4 1.01 12 gauge 1.02 14 gauge 1.03 16 gauge 1.04 18 gauge 1.05 other gauges 1.06 aluminum patra 8x4 1.07 12 gauge 1.08 14 gauge 1.09 16 gauge 1.1 18 gauge 1.11 other gauges 1.12 lokhandi plate 1.13 10 gauge plate 1.14 18 gauge plate 1.15 14 gauge plate 1.16 16 gauge baffle plate 1.17 18 gauge baffle plate 1.18 other gauges 1.19 aluminum 1.2 10 gauge plate 1.21 18 gauge plate 1.22 14 gauge plate 1.23 16 gauge baffle plate 1.24 18 gauge baffle plate 1.25 other gauges 1.26 galvanize sheet 1.27 16 gauge 1.28 18 gauge 1.29 other gauges 1.3 aluminum sheet 1.31 16 gauge 1.32 18 gauge 1.33 other gauges 1.34 lokhandi angle 1.35 25x25x3 mm 1.36 25x25x5 mm 1.37 35x35x5 mm 1.38 40x40x5 mm 1.39 50x50x5 mm 1.4 other sizes 1.41 aluminum angle 1.42 25x25x3 mm 1.43 25x25x5 mm 1.44 35x35x5 mm 1.45 40x40x5 mm 1.46 50x50x5 mm 1.47 other sizes 1.48 lokhandi pattri 1.49 25x3 mm 1.5 25x5 mm 1.51 32x5 mm 1.52 35x5 mm 1.53 40x5 mm 1.54 50x5 mm 1.55 other sizes 1.56 aluminum strip 1.57 25x3 mm 1.58 25x5 mm 1.59 32x5 mm 1.6 35x5 mm 1.61 40x5 mm 1.62 50x5 mm 1.63 other sizes 1.64 lokhandi pipe ( galvanize ) 1.69 lokhandi sali ( round bar ) 1.7 6 mm 1.71 10 mm 1.72 12 mm 1.73 16 mm 1.74 other sizes 1.75 lokhandi chain 1.76 1 / 2 inch link 1.77 1 inch link 1.78 1 1 / 2 link 1.79 2 inch link 1.8 3 inch link isi in 1.81 vegvegalia size. mark wire rope 1.82 lokhandi channel 1.83 75x40 mm 1.84 100x50 mm 1.85 other sizes 1.86 aluminum channel 1.87 40x40x6 mm 1.88 50x50x6 mm 1.89 100x50 mm 1.9 other sizes 1.91 garden hose pipe 1.92 1 1 / 2 inches 1.93 2 inch 1.94 2 1 / 4 inch 1.95 3 inch 1.96 other sizes 1.97 speedy killer / tools 1.98 p.wh. c. pipe 1.99 1 1 / 2 inches 2 3 inch 2.01 other sizes 2.02 suction hose pipe 2.03 2 1 / 2 inches 2.04 3 inch 2.05 3 1 / 4 inch 2.06 other sizes 2.07 lokhandi whole whole 2.08 1 / 4 inch 2.09 1 1 / 4 inches 2.1 2 inch 2.11 2 1 / 4 inches 2.12 3 inch 2.13 other sizes 2.14 gun metal whole 2.15 1 / 4 inch 2.16 1 1 / 4 inches 2.17 2 inch 2.18 2 1 / 4 inches 2.19 3 inch 2.2 all types of lokhandi nuts, bolts, washers and tarmole etc. 2.21 whi belt 2.22 c. 52 2.23 c. 55 2.24 c. 58 2.25 c.63 2.26 other sizes 2.27 all types of plumbing material 2.28 canvas print 2.29 2 inch 2.3 by 2 1 / 4 inches 2.31 3 inch 2.32 other sizes 2.33 gland 2.34 6 mm 2.35 8 mm 2.36 10 mm 2.37 other sizes 2.38 quire sponge 2.39 3x6 ( 2 inch thick ) 2.4 3x6 ( 3 inch thick ) 2.41 other sizes 2.42 rexine 2.43 foam rexine red 2.44 foam rexine black 2.45 foam rexine brown 2.46u foam 3x6 2.47 10 mm 2.48 15 mm 2.49 25 mm 2.5 other sizes 2.51 other material 2.52 solution box 125ml 2.53 dora reel con 2.54 cotton vest 2.55 lokhandi screw 2.56 tex 2.57 retweet 2.58 whexa blade ( 100 nos. ) 2.59 m. sil. packet 2.6 gasket bottle 2.61 oil paper 2.62 polished paper 2.63 rubber packing white 2.64 pedestal bearing 2.65 other hardware material 2.66 vehicle glass 2.67 seat cover 2.68 foot mating 2.69 tire matting 2.7 air freshener 2.71 cent bottle 2.72 rewinding lamp 2.73 flag rod 2.74 wheel cap 2.75 sit knee plant 2.76 other accessories 2.77 paint brushes and brush literature 2.78 apco brilliant white 2.79 apco silver aluminum paint 2.8 apco light gray / smoke gray 2.81 apco p.o. red 2.82 apco signal red 2.83 apco merced 2.84 apco oxford blue 2.85 apco opaline green 2.86 apco black 2.87 apco deep orange 2.88 apco pale cream 2.89 apco golden yellow 2.9 apco tata memosa 2.91 apco a. d. gray 2.92 apco turpentine tyne 2.93 apco firoza blue 2.94 car patch 2.95 japan black 2.96 lemon yellow 2.97 polished paper 100, 150, 320 nos. 2.98 red radium per foot 2.99 white radium per foot 3 rubbing polish per kg 3.01 vans polish per kg 3.02 brush 1 inch 3.03 brush 2 inch 3.04 brush 4 inch 3.05 sable helper brush no. 6 3.06 sable helper brush no. 10 3.07 sable helper brush no. 12 3.08 round brush no. 5 3.09 round brush no. 8 3.1 round brush no. 10 3.11 round brush no. 12 3.12 miscellaneous material other than hardware material, spare parts, accessories etc. che rate sheet available with asless tender...

Military Engineer Services - Maharashtra

37602652 repairs to plumbing, sanitary fittings, plastering and connected misc br works at aicts, ngm, ogm, fafa qtrs area under age br i south pune 1 taking up or down steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed for following size of pipe : 2 15mm bore 3 20mm bore 4 25mm bore 5 40mm bore 6 refixing old serviceable steel tubing and connection in new or old position (wall, ceiling floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed for following size of pipe : 7 15mm bore 8 20mm bore 9 supplying, fixing, jointing and testing galvanised steel tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floor complete all as specified and as directed for the following sizes: 10 15mm bore (concealed) 11 20mm bore (concealed) 12 25mm bore 13 40mm bore 14 s&f ppr pipeswith all fittings and fixtures, fixed to walls or ceiling or laid in floors etc. complete all as specified and directed for the following sizes : 15 15mm bore (concealed) 16 20mm bore (concealed) 17 demolition and breaking of drain pipes ac /ci/pvc set in cementmortar or adhensive of 75mm to 110 mm dia, complete all as specified and directed. 18 s&f in repairs pvc (swr) pipes, single socketed in any length with rubber ring joints fixed to wall / ceiling or laid in trenches, complete all as specified and directed for following size : 19 110mm bore 20 75mm bore 21 refixing of pvc (swr) pipes, single socketed in any length with rubber ring joints fixed to wall / ceiling or laid in trenches incl taking down the old pipes, complete all as specified and directed for following size : 22 100mm bore 23 75mm bore 24 s&f pvc (swr) bends any radius 110 mm bore, complete all as specified and directed. 25 s&f pvc (swr) bends any radius 75 mm bore, complete all as specified and directed. 26 s&f pvc (swr) vent cowl 100 mm bore, complete all as specified and directed. 27 s&f pvc swr branch piece, (double y) equal or unequal of 110 mm bore, complete all as specified and directed. 28 m&l for replacement for pvc (swr) gully trap 125/100mm, setting and jointing with solvent cement, complete all as specified and directed. 29 s&f in repairs pvc (swr) floor trap, dia of outlet 75mm, plain with grating including jointing with solvent cement, complete all as specified and directed. 30 s&f in repairs 15mm bore pillar tap of long body, chromium plated, fancy type including with elbow operated type, complete all as specified and directed. 31 s & f in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, , complete all as specified and directed forfollowing sizes : 32 15mm bore 33 20mm bore 34 25mm bore 35 40mm bore 36 50mm bore 37 s&f in repairs stainless steel sink with drainage board 1 mm thick for kitchen, with plug, waste pipe, washers incl cantilever ci brackets, connecting union etc & connecting to inlet/out let for smooth functioning size of sink 915 x 460 mm overall and bowl size 410mmx330mmx160mm, , complete all as specified and directed. 38 s&f in repairs stainless steel, sink 1 mm thick for kitchen or laboratory, with plugs, waste pipe, washers; incl bedding in cement mortar on to dwarf wall or including fixing cantilever ci brackets, connecting union etc & connecting to inlet/out let for smooth functioning size of sink 495 x 420mm overall and bowl size 410mmx330mmx160mm, including pvc connection, cp waste coupling,etc. , complete all as specified and directed. 39 s&f in repairs stainless steel plate rack of size 36x30x10, made from 1mm thick stainless steel, complete all as specified and directed. 40 s & f in repair waste coupling, brass cp suitable for sink / basins of 40mm bore, complete all as specified and directed. 41 s & f in repairs plastic water closet seat of any colour, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed. 42 s&f in repair 15mm bore bib cock standard of ptmt screwed down high pressurehandle screwedfor iron pipe or for unions, complete all as specified and directed. 43 s&f in repairs stop valves 15mm bore of ptmt screwed down of any colour high pressurescrewed both ends for iron pipe or for unions, complete all as specified and directed. 44 s & f in swivel shower of ptmt any colour for fixing with 15mm pipe. (minimum weight 40gms), complete all as specified and directed. 45 s&f in repairs high density polythene pipe 40mm dia (hdpe) of pressure rating 6kgf/cm²fixed to wall or floor incl bend, tee, elbow etc., complete all as specified and directed. 46 s & f in repairs pvc flexible waste pipe 32mm bore of suitable length as per site requirement, complete all as specified and directed. 47 s&f in repairs pillar taps of ptmt, any colour, high pressure, screwed for iron pipe, fancy type, for bore of pipe 15mm, complete all as specified and directed. 48 s & f in repair grating doom of ptmt (minimum wt 25 gms) 75 to 100 mm dia, complete all as specified and directed. 49 s & f in repairs pvc connection 60 cm long 15 mm bore with 2 nos ptmt check nuts, complete all as specified and directed. 50 s&f in repairs wall mixer 3 in 1 including telephone showerfor 15mm bore of pipe conforming to cat no. con 269 of jaquar or of equivalent make as specified here in after, complete all as specified and directed. 51 s&f in repairs 15mm bore bib taps, brass chromium plated, cast copper alloy fancy type handle, screwed down, screwed for iron pipes, complete all as specified and directed. 52 s&f in repairs 20mm bore ‘d’ type stainless steel tubular towel rail 60 cm long between flanges, complete all as specified and directed. 53 s&f in repairs stainless steel toilet paper holder of suitable size, complete all as specified and directed. 54 s&f bottle trap 32 mm bore dia of discharge of chromium plated having minimum water seal 25mm minimum, complete all as speciifed and directed. 55 s & f in repair stainless steel towel square ring of required size, complete all as specified and directed. 56 s&f in repairs brass chromium plated shower rose with or without swivel joints, any size including fixing to a steel pipe or union of size 125mm size, complete all as specified and directed. 57 s & f in repair stop valve, fancy type, 15mm bore brass chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by engineer in charge. 58 s&f in repairsstainless steel soap dish, brass chromium plated, complete all as specified and directed. 59 s&f in repairs, pillar taps, fancy type, cp 15mm dia cast copper alloy with capstan heads, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed. 60 s & f in repairs, two way bib cock brass cp as in toilet fittings conforming to cat no. 35041 as mentioned of make jaquar or of equivalent make specified here in after, complete all as specified and directed. 61 s & f in repair stainless steel cp health faucet with flexible pipe fancy type, complete all as specified and directed. 62 s&f in repairsbrass cp, jet spray assembly complete all as specified and as directed. 63 s&f in repairs brass cp, fancy type long necktaps, cast copper alloy with capstain head suitable for ovel type whb, complete all as specified and directed. 64 s&f in repairs vitreous china, squatting pan, orissa pattern, size 580 x 440mm white, with integral foot rest, including concrete bedding and pvc flushing cistern 10 ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 65 s & f in repairs vitreous china wash basin white flat back of size 550mm x 400mm including 15mm dia ptmt pillar tap, ptmt waste coupling 32mm, chain and plug and pvc waste pipe including ci brackets, etc. complete all as specified and directed. 66 s&f in repairs vitreous china wash down water closet pan, pedestal white, including fixing bolts etc including pvc seat cover white with flat bottom including ms, cp or aluminium anodised hinge devices including pvc low level flushing cistern 10 ltr capacity with all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed. 67 s & f in repairs spindles of any size suitable for concealed mixer valves, stop valves, angle cock, fancy taps including knob heads etc. complete all as specified and directed. 68 s&fin repair pvc low level flushing cistern 10 ltrs capacity including all internal fitting, pair of bracket, including inlet/outlet pvc pipe connections etc, complete all as specified and directed. 69 s&f in repairs flush pipe of polyethyline of low or high density or pvc 32mm dia suitable for low level cistern, complete all as specified and directed. 70 s & f in repairs vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing & fixing, plugs, bedding urinal against wall in cm 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around, urinal back in cement etc complete all as specified and directed. 71 s&f in repairs,looking mirror 4mm thick selected quality glassof approved size 600x 450mm bevelled edge mounted on pvc sheet backing with pvc colour frame of approved colour, complete all as specified and directed. 72 s&f in repairs pvc box type cabinet of size 45 x 35 x 10 cm with 3mm thick mirror mounted on shutter with pvc shelves inside fixed in existing opening of wooden cabinet, complete all as specified and directed. 73 s&f in repairs vitreous china ceremic white single piece wc (s or p trapp with uf soft close seat cover , hinges, accessorires set, size 365x655x765 mm, product code : lys wht 38851ssm of jaquar of equivalent make approved by gecomplete all as specified and directed 74 s&f in repair tubular towel rack cp (make ess ess cat no tm 08)or equivalent appvoved, complete all as specified and directed. 75 s&f in repair cascade type (coloured) floor mounted water closet with lowlevel flushing cistern single piece coloured with floor trap , pvc coloured seat cover and connecting pipe etc complete all as speicifed and directed by engr in charge make: jaquar cat no.fns wht 40751p180ufsmz or equivalent make as mentioned here in after 76 s&f in repair vitreous china (coloured) urinal concealed wall mounded sensor (new model) including all necessary fixing arrangement complete all as specified and directed. make:ess ess model no 202clamb or equivalent. 77 s&f in repair chromium plated sensor pillar tap superior quality including all necessary arrgangemet complte (make:ess essor equivalent), complete all as speicified and directed 78 demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as speicified and directed. 79 m&l for cutting holes into or through brick wall built in cement mortar, superficial area exc. 150 sq. cm but n. exc. 400 sq. cm and making good the dismantled portion in cm 1:3 or cement concrete 1:2:4 type b 1 as required, complete all as specified and directed. 80 demolition of stone slab & tiles of any description or thickness infloor, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed. 81 m&l for 75mm thick pcc (1:4:8) type d 2 (using 40mm graded stone aggregate) as in sub base / flooring, complete all as specified and directed. 82 m&l for pcc 1:2:4 type b 0, 25mm average thickness, levelling course as in padding, complete all as specified and directed. 83 m&l for 300x300x 6 to 7mm thick, non skid, ceramic, coloured tiles, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete laid over and including 15mm thick screed bed in cm 1:6, complete all as specified & directed. 84 m&l formatt finished, coloured ceramic tiles 7 to 8 mm thick 600 x600mm size of approved colour, set, jointed in cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 20 mm thickscreed bed in cm 1:6 etc as in flooring, complete all as specified and directed. 85 m&l for 300x450x5.5 to 6mm thick, coloured, glazed ceramic tiles as in skirting /dado, laid and jointed in neat cement slurry and pointed in coloured cement to match complete laid over and including 10mm thick backing coat in cm 1:4 including triangular filleting on top in cm 1:4 complete all as specified and directed by engr in charge. 86 m&l for vitrified colouredtiles10 mm thick (square / rectangular) polished area of each tiles exceeding 0.36 sqm but not exc. 0.42 sqm in floors, set an jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20 mm thickscreedbed in cm 1:6, complete all as specified and directed. 87 m & l for granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick as in steps, jambs, pillars, window cill, cooking platform and flooring set in cm 1:4 including pointing in white cement 1:2 using marble dust without mixture of pigment to match with shed of granite including 15 mm thick screed bed of cm 1:4, complete all as specified and directed. 88 m&l for machine cut cudappah stone slab 20 to 25 mm thick, set, jointed & pointed in grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing etc complete all as specified and directed. 89 rounding to edges of stone slab one edge, such as insteps, cooking platform and other similar situations, complete all as specified & directed. 90 demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed. 91 m&l for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius, builtin cm 1:6 complete, complete all as specified and directed. 92 taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water, complete all as specified and directed. 93 m&l for dubbing out average 15mm thick in cm 1:6 on irregular faces of walls (when specifically ordered in writing) by using ready mix plaster, complete all as specified and directed. 94 m&l for rendering (as subsequent coat) 10mm thickin cm 1:6 by using ready mix plaster over dubbed out surfaces, finished the surfaces even & smooth with sagol finish, complete all as specified and directed. 95 m&l for rendering 15mm thickin cm 1:4by using ready mix plaster duly mixed with wpc as per manufacturers instruction, on brick / concrete surface finished even and smooth using extra cement, complete all as specified and directed. (note : wpc shall be measured and paid separately.) 96 supply only integral water proofing compound, complete all as specified and directed. 97 m&l for preparation of new plastered surfaces and applyingtwo coats of wheather proof paint, complete all as specified and directed. 98 m&l for preparing newly plastered surfaces of walls and applying two coats of oil bound distemperover a coat of alkali resistant primer, complete all as specified and directed. 99 s&f in repairs following capacity rotational moulded polythylene water storage tanks of double layered (cylindrical vertical with colsed top) hoisted and fixed in postion with and including 20mm bore ball brass valve, high pressure, with polythene float and flynut and tank nipple of suitable size, complete all as specified and directed. 100 500 ltr. 101 1000 ltr. 102 2000 ltr. 103 s&f in repair brass unionsto connect iron to polyethylene and fixed with following bore dia of pipe, complete all as specified and directed. 104 20mm bore 105 25mm bore 106 40mm bore 107 s&f in repairball valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed with following dia, complete all as specified and directed. 108 20mm bore 109 25mm bore 110 40mm bore 111 m&l for cleaning and removing all dirt and scale etc from tank and from the mouths of circulating pipes from the tanks of following capacity, complete all as specified and directed : 112 not exc. 500 ltrs 113 not exc. 1000 ltrs 114 not exc. 2000ltrs 115 not exc. 5000ltrs 116 s&f in repairs, pvc cover suitable for water storage tank of500 litres capacity fixed with pvc locking arrangements, complete all as specified and directed. 117 m&l forpcc (1:2:4) type b1 (using 20mm graded stone aggregate) as in water tank base etc, complete all as specified and directed. 118 m & l for water proofing treatment to sunken slab, walls etc, shall be carried out with and including the following provisions as mentioned below complete all as specified and directed by engineer in charge.(note : this item is continuedat sl no.86.01to 86.06 below ) (a) m&l for 15mm thick plaster / screed bed layer in cement mortar (1:3) on concretesurfaces andusing extra cement mixed with including approved make wpc @ 3% wt of cement all as directed by engr in charge. (b)preparing plastered surfaces of sunken slab, walls, etc, by brooming with broom sweeping free from dirt dust etc & form angle fillet of size 40mm x40mm along the junction of wall and floor using polymer modified mortar (“dr fixit” pidicrete urp” or equivalent make. (c) sanitary pipes entering through walls and floor shall be sealed with “dr fixit bathseal tape” and the gaps to be grouted with non shrink cementitousgrout “dr fixit bathseal grout” or equivalent make. nahani traps etc to be fitted securely and the gaps around it to be grounted in the same mannerall as specified & directed by engr in charge. (d) apply one coat of a bitumen modified polymer coating “dr fixit bathseal plus” or equivalent make on all angle fillets by brush and cover it with mm ope woven mesh when it is still wet. apply second coat of the same coating on the angle fillets and allow it to dry completely 119 item no. 85.00 above (contd.....) (e) in the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. extend the coating upto 150mm above the ffi. above ffi, another cementitious waterproofing waterproof coating “dr fixit pidifin 2k” or equivalent make can be further applied right upto 2.1m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6 8 hours and allow to dry completely (f) after 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed m 15 type b0 mixed with integral wpc (liquid) laid to stope 1:60 towards outer face of wall. provide 40mm od (g) carrying out test by floodingwater for 24 hrs for leakage & seepages and rectifying the same to theentire satisfaction of engr in charge. upvc pipe at the lowest point with 300mm projection beyond the outer face of the wall shall be provided. then fill up the sunken portion with lean concrete 1:5:10 type e2. (note : lean concrete will be measured and paid separatily) 120 m&l for pcc 1:5:10 type e2 (using 40 mm graded brick aggregate) lean concrete for filling sunkan floor etc. , complete all as specified and directed. 121 m&l for pcc 1:2:4 type b0 (using 12.5 mm graded brick aggregate) as in coving rounded, chamfered,sub base above lean concrete etc on sunken floor, complete all as specified and directed. 122 removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and and removing the rubbish off the premises to a distance exc 500 m, complete all as specified andas directed. 123 m & l forwater proofing treatment to rcc roof slab, walls, chhajjas etc. shall be carried out with and including the following provisions as mentioned below complete all as specified and directed by engineer in charge. (a) m&l for 10mm thick plaster screed bed layer in cm 1:3 on concrete surfaces. (b)preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 kg/sqm of area complete allas directed. (c) laying app polymer modified approved membrane, non woven,polyester, weighing not less than 3.5 kg / sqm with laps & overlaps asspecified & joints sealed and applied complete by torch application methodall as specified & directed by engr in charge and on completion of water proofing treatment to carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to theentire satisfaction of engr in charge at his own cost. (d) finally applying a coat of solar reflective bituminous aluminium paint@ 0.15 ltr / sqm on the top of membrane surfaces, complete all as specified& as directed by engr in charge. 124 removing of existing water tank of capacity 500,1000 or 2000 ltr setting aside (or lowering if required) for repair, cleaning etc and reconnecting & refixing in position after carrying out necessary roof treatment including necessary fittings and gi pipes if required, complete all as specified and directed. (note : necessary by pass arrangements for water supply is to be done by the contractor till completion of roof work at his own cost) 125 removing building including loading, unloading and stacking at the destination to a distance not exc. 5 km of outside of md land, complete all as specified and directed. 126 dismantling of asbestos cement (corrugated, semicorrugated etc.) sheets as in roof covering, including wind tie etc, complete all as specified and directed. 127 s & f 6 mm thick asbestos cement , corrugated or semi corrugated sheetsin roof, walls etc fixed with l or j type hooks as in patches, complete all as specified and directed. 128 all as per item no. 92.00 above but fixing only, complete all as specified and directed. 129 s&f in repairs 110mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls / trenches / floor, complete all as specified and directed. 130 re fixingof 110mm dia pvc (swr) pipes single socketed in any length with rubber ring joints fixed to walls / trenches / floor, complete all as specified and directed. 131 s & f in repairs110mm dia., pvc (swr) bends any radius, complete all as specified and directed. 132 taking down chowkat wooden / steel with shutters (without taking off shutters from frame) n.exc 1.5 sqm each, complete all as specified and directed. 133 taking down shutters of any description exc. 1 sqm but not exc. 2 sq m each, complete all as specified and directed. 134 s & fsolid pvc door frame of size 50mm x47mm made out of 5mm plain colour pvc sheet reinforced with ms tube, suppling and fixing in opening complete all as per specification and as directed by engr in charge 135 s&f factory made solid panel pvc door shutter 30mm thick (stiles) consisting of frame made out of m.s tubes for top & bottom rails; m.s frame shall be covered with heat moulded plain colour pvc ‘c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s. frame welded / sealed to the stiles & rails with suitable pvc sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing as per product drawing given ssr part ii2020 refer item no. 8080 as specified and directed by engr in charge. 136 s&faluminium powder coatedventilators / louvers 5mm thick x10cm wide frosted glass strips and following aluminium powder coated sec conforming to catalogue of jindal or of equivalent make and rubber beading etc, complete all as specified and directed. : (a) sp 20048 (b)glazing clips 19352 137 dismantling of walls/ceiling boards(fibre, pulp, insulation, etc) or insulation boards/ slabs / blankets, any thickness including cover fillets etc, complete all as specified and directed. 138 m&l for gypsum ceiling board for ceilingprepainted, perforated finish, 600 x 600 x 8 to 9 mm thick in size, of approved brand/make, laid over and including grid work of size 595 x 595mm, made out of 0.5mm thick g.i. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick g.i. suspension wires spaced at 1200 mm on main runners including making niches for fans / light, complete all as specified and directed. 139 s&f aluminium powder coatedthree track sliding window with two or more shutters with & including4 mm thick tinted glass, one shutter of stainless steel mosquito proofing with good qualitybearing,handle, lock etc using pvc beadingetc using following sections of `jindal aluminum ltd or equivalent in ajit india pvt ltd or crystal bombay, as approved. fixing to stone masonary walls with & including ist class hard wood teak plugs of size 20mmx20mm at an interval of 0.5m alround the track including drilling holes etc , complete all as specified and directed. (a) frame bottom 20620 (b) frame top& side 20681 (c) shutters top & bottom 20844 (d) shutter inter lock 20724 (e) handle (side ) for 20606 shutters 140 s&faluminium powder coated single leaf door on pivots alongwith hydraulic door closer, door lock, handles, 5mm thickglass i panel andetc., fixed with rubber beading and glazing clips andusing following sections of `jindal aluminum ltd or equivalent in ajit india pvt ltd or crystal bombay, as approved all as directed by engineer in charge (a) rectangular tube 14005 (b) shutter vertical (c) shutter top rail 19503 (d) shutter middle rail 060 (e) shutter bottom rail 19511 (f)glazing clips 19352 141 s&f aluminium powder coated partition using following sections of `jindal aluminum ltd or equivalent in ajit india pvt ltd or crystal bombay, as approved with 12 mm thick both side prelaminated particleboard interior grade of approved colour in bottom panel and 5mm thick plain glass in top panel fixed with aluminium clips, beads, rubber gaskets etc., centre to centre distance of vertical member shall not exceeding 1mtr and horizontal member shall not exceeding 1.10 mtr using following aluminum section as specified in jindal catalogue complete as directed fixing to stone masonary walls with & includingist class teak wood plugs of size 20mmx20mm at an interval of 0.5m alround the track including drilling holes etc , complete all as specified and directed: (a)sp – 20048 (b)dp 20047 (c)glazing clips 19352...

Municipal Council - Maharashtra

37202221 supplying electrical materials for streetlight repair, installation of high mast pole and streetlight pole, light fitting and other electrical works as required by mangalvedha municipal council electricity department. 1 2x1.5 sq.mm frlsh copper pvc insulated wire 2 2x2.5 sq.mm frlsh copper pvc insulated wire 3 2x4 sq.mm frlsh copper pvc insulated wire 4 2x6 sq.mm frlsh copper pvc insulated wire 5 2x10 sq.mm frlsh copper pvc insulated wire 6 3x2.5 sq.mm frlsh copper pvc insulated wire 7 3x4 sq.mm frlsh copper pvc insulated wire 8 3x6 sq.mm frlsh copper pvc insulated wire 9 3x10 sq.mm frlsh copper pvc insulated wire 10 4x16 sq.mm frlsh copper pvc insulated wire 11 1 sq.mm ( 32 no. x0.20mm dia. ) 3 core flexible multi stranded copper 12 wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires 13 xlpe insulated unarmoured cable 1100 v 1 core 70 sq. mm. aluminium conductor 14 xlpe insulated unarmoured cable 1100 v 1 core 95 sq. mm. aluminium conductor 15 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium 16 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor 17 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor 18 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 4 sq. mm. aluminium conductor 19 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 6 sq. mm. aluminium conductor 20 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 10 sq. mm. aluminium conductor 21 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 16 sq. mm. aluminium conductor 22 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 25 sq. mm. aluminium conductor 23 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½ core 70 sq. mm. aluminium conductor 24 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor 25 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½core 240 sq. mm. aluminium conductor 26 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 6 sq. mm. aluminium conductor 27 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminium conductor 28 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductor 29 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor 30 modular type switch 6a / 10a 31 modular type switch 16a 32 modular type bell push with indicator 2 modules 6a / 10a 33 modular type two way switch 6a / 10a ( 2 module 34 modular type switch 16 / 20 a with indicator 35 modular type d.p. switch 32a with indicator 36 modular type 32a, dp key tag switch with key tag 37 modular type 3 pin 6a multi socket with safety shutter 38 modular type 3 pin 6 / 16a multi socket with safety shutter 39 modular type 6 / 16a fuse 40 modular type ( two module ) electronic step regulator for fan 41 modular type blanking plate one module 42 modular type blanking plate two module 43 ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. 44 adaptor for lamp holder 45 pvc surface modular switch box with double mounting plate for 2module 46 pvc surface modular switch box with double mounting plate for 3module 47 pvc surface modular switch box with double mounting plate for 4 module 48 pvc surface modular switch box with double mounting plate for 6module 49 pvc surface modular switch box with double mounting & front plate for 8 module 50 pvc surface modular switch box with double mounting plate for 12module 51 pvc surface modular switch box with double mounting plate for 16 / 18 module 52 concealed type modular switch box with double mounting plate for 1 module 53 concealed type modular switch box with double mounting plate for 2 module 54 concealed type modular switch box with double mounting plate for 3 module 55 concealed type modular switch box with double mounting plate for 4 module 56 concealed type modular switch box with double mounting plate for 6 module 57 concealed type modular switch box with double mounting plate for 8 module 58 concealed type modular switch box with double mounting plate for 12 module 59 concealed type modular switch box with double mounting plate for 16 / 18 module 60 white footlight with 4 modules concealed modular box and led lights 61 16 / 20 / 25 a starter ( modular range ) 2 module 62 6 to 32 a, 10ka, spmcb suitable to fix in 1 module 63 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module 64 pvc surface modulardouble mounting plate 1 module 65 pvc surface modulardouble mounting plate 2 module 66 pvc surface modulardouble mounting plate 3 module 67 pvc surface modulardouble mounting plate 4 module 68 pvc surface modulardouble mounting plate 6 module 69 pvc surface modulardouble mounting plate 8 module 70 pvc surface modulardouble mounting plate 12 module 71 pvc surface modulardouble mounting plate 16 / 18 module 72 hms pvc conduit frls grade 25 mm dia 73 hms pvc conduit frls grade 32 mm dia. 74 single pole and neutral distribution board ( spndb ) , with 2 ways for incoming and 6 ways ( 6 poles ) for outgoing sp mcbs 75 single pole and neutral distribution board ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs 76 spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka 77 spmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka 78 dpmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka 79 2 pole rccb 40a 80 2 pole rccb 63a 81 4 pole rccb 16 / 25a 82 copper earth plate size 30 x 30 x 0.315 cm complete 83 energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm 84 pre wired box type fitting / batten suitable for 4 feet, t8 led tube light 85 5w 7w, 230v integral type led lamp 86 10 12w, 230v integral type led lamp 87 14w, 230v integral type led lamp 88 led square / circular max. 11 w down lighter / panel light 89 led square / circular max. 18 w down lighter / panel light 90 led strip light 5m length max. 45 w ip20 class 91 street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length 92 street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length 93 16 amp. 3 pin plug top bakelite type 94 single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time ofhrs. based on insulated gate bipolar transistor ( igbt ) technology complete 95 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty 96 cabin fan of a.c. 230 v. 50 cycles 250 mm. / 300 mm. sweep 97 cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep 98 fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm 99 spmcb 0.5a to 5a, c series with rated short circuit breaking capacity ( icn ) 10ka 100 tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka 101 triple pole isolators only switch version of miniature circuit breaker of 40a 102 triple pole isolators only switch version of miniature circuit breaker of 63a 103 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , 104 3 pole mccb, 415v, 200a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , 105 four pole isolators only switch version of miniature circuit breakers of 63a 106 mcb type change over switch 2 pole, 40 a 107 mcb type change over switch 4 pole, 63a with 3 positions 108 triple pole and neutral distribution board ( tpndb ) , spmcb of 8 ways / phase 24 poles 109 triple pole and neutral distribution board ( tpndb ) , sp / tp mcbs total 8 ways / 24 poles 110 triple pole and neutral distribution board ( tpndb ) , 3 pole / 4 pole mccb as incomer & outgoing sp mcb ( 36 poles ) or tp mcb of 12 ways ( 36 poles ) , 111 electronic type cordless call bell 112 condenser 2.5 micro farad for ceiling fan 113 anchor type fastener fan hook 114 fan hook box of 10 mm m.s. round 115 pvc trunking ( pvc casing n capping ) of size 25 mm 116 pvc trunking ( pvc casing n capping ) of size 32 mm 117 pvc trunking ( pvc casing n capping ) of size 40 mm 118 iron clad cut out hc type 415v, 32a 119 iron clad cut out hc type 415v, 63a 120 iron clad cut out hc type 415v, 100a 121 iron clad cut out hc type 415v, 200a 122 led street light fitting 18 to 22w ip65 & ik08 class 3 years warranty 123 led street light fitting 60w ip65 & ik08 class3 years warranty 124 led street light fitting 70 75w ip65 & ik08 class 3 years warranty 125 led street light fitting 100 110w ip65 & ik08 class 3 years warranty 126 led flood light fitting max. 100w ip65 & ik07 class 3 years warranty 127 led flood light fitting max. 120w ip65 & ik07 class 3 years warranty 128 led flood light fitting max. 195w ip65 & ik07 class 3 years warranty 129 c 10 battery with capacity of 12v, 40 ah with duty cycle 10 12 hrs. 130 c 10 battery with capacity of 12 v, 75 ah with duty cycle 10 12 hrs. 131 two pole power contactor 230 v, 32 a 132 four pole power contactor 430 v, 40 a 133 programmable digital almanac timer microcontroller based 134 5 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 135 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 136 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 137 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 200 mm a / f, top 100 mm a / f 138 galvanised 1000mm single arm sword type bracket with frp dome and ball 139 galvanised 1000mm double arm sword type bracket with frp dome and ball 140 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures 141 g.i. pipe ‘a’ class 40 mm dia. 142 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe 143 pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials 144 making trench in hard murum / tar road having 0.75 m depth and minimum 0.3mtr width 145 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 146 making cement concrete foundation in 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing for complete. ( pole muffing or any other purpose ) . 147 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 3 to 5m octagonal / conical gi pole ) . 148 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 149 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 150 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal / conical gi pole ) . 151 gi sheet 1 mm ( 20 swg ) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 152 supplying and erecting rolled steel joist ( girder ) pole 175 x 85 mm ( 19.6 kg / m ) with provided base plate in provided foundation as per specification no. ohpl / rsj 153 supplying and erecting rolled steel joist ( girder ) pole 100 x 116 mm ( 23 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 154 supplying and erecting rolled steel joist ( girder ) pole 200 x 100 mm ( 25.9 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 155 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm. complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 156 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm.complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 157 supplying and erecting 3 phase 4 core 16 sq.mm. ( 3x16+1x25 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 158 supplying and erecting 3 phase 4 core 25 sq.mm. ( 3x25+1x25 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 159 supplying and erecting 3 phase 4 core 95 sq.mm. ( 3x95+1x70 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 160 supplying and erecting 3 phase 5 core 16 sq.mm. ( 3x16+1x25+1x16 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 161 supplying and erecting 3 phase 5 core 70 sq.mm. ( 3x70+1x50+1x16 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 162 supplying and erecting 6 way ab cable distribution box on provided pole with necessary accessories as per specification no. oh abc / jbs 163 supplying and erecting 9 way ab cable distribution box on provided pole with necessary accessories as per specification no. oh bc / jbs 164 supplying and erecting 12 way ab cable distribution box on provided pole withnecessary accessories as per specification no. oh abc / jbs 165 10kw, 3 x 3.3 kw ac electric vehicle charger ( suitable for 2 / 3 / 4 wheeler ) having minimum ik08 / ip 54 protection suitable for three phase, 415v ac, 50hz incoming and 3 nos. output as per iec 60309 industrial sockets having capacity of outputcurrent of 16a 240v ac at each socket 166 supplying and installation of solar pv module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 kw solar pv module. ( approx. 35 sq. mtr. pv module area ) . 167 reel insulator 168 “c” clamp bolts and nut 169 khekada clamp bolts and nut 170 pin type lt medium insulator 100 mm x 62 mm dia. with suitable g.i. spindle, nut, bolts 171 aluminium bobbin with g.i. ( shackle ) strip, nuts 172 g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 8 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps 173 pole clamp made from 50 x 10 mm ms flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 174 ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 175 c type ( half ) clamps for pole made from 50 x 6 mm flat for fixing cross arms by means of 15 mm dia. bolts and nuts painted with one coat of red oxide and two coats of aluminium paint. 176 telephone copper cable 2 pair with 0.5 mm dia. laid in provided pvc 177 fuse wire 63amap 178 35x8 screw 179 25x8 screw 180 rawl plug 181 20x25 cm sanmaik board 182 8x10 cm sanmaik board 183 electrical wiring labour coast 184 high speed electric drill machine 185 copper pin type lugs 10mm2 186 copper pork type lugs 10mm2 187 copperterminal type lugs 10mm2 188 aluminum lugs 70mm2 189 aluminum lugs 12mm2 190 crimping tools 191 taparia 1022 home tool kit – 1022 by taparia | sku: t02 487 192 meco 36 auto 400a ac / dc digital clamp meter 36 auto by meco | sku: t13 060 193 taparia socket set ( pack of 23 ) 194 taparia kbhm9l allen key set 195 taparia 1812 n double ended ring spanners set ( pack of 12 ) 202 short time delay circit with ic 55 ( for linr reactor ) 203 insulation tape 204 panel box2x2.5 standred 205 solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 100 wp, 12v 206 solar led street light luminarire assembly 207 distilled water 208 led street light driver 20 25watt 209 led street light driver 25 30watt 210 led street light driver 36watt 211 led street light driver 40watt 212 led street light driver 60watt 213 led street light driver 70 75watt 214 led street light driver 100 120watt 215 led street light driver 120 150watt...

Directorate Of Municipal Administration - Maharashtra

37141987 tender for supplying required electrical materials and doing essential electrical work under municipal council hinganghat 2nd call. 1 supplying & erecting h.m.s. p.v.c. conduit 20 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 2 supplying & laying hms pvc conduit 20 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 3 supplying & erecting hms p.v.c. conduit 25 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 4 supplying & laying hms pvc conduit 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 5 supplying and erecting upvc reinforced flexible conduit 20 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 6 supplying and erecting upvc reinforced flexible conduit 25 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 7 supplying and erecting hms pvc conduit 20 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 8 supplying and erecting hms pvc conduit 25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 9 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 20 mm with accessories on wall / ceiling as per specification no: wg ma / con. 10 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 25 mm with accessories on wall / ceiling as per specification no: wg ma / con. 11 supplying & erecting mains with 2x1.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 12 supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 13 supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 14 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 15 supplying & erecting mains with 2x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 16 supplying & erecting mains with 3x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 17 supplying & erecting mains with 3x4 sq.mm fr copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 18 supplying & erecting mains with 3x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 19 supplying & erecting mains with 3x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 20 supplying & erecting mains with 4x16 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 21 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 22 supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6a. erected on filledpolypropylene board or polished double wooden block / pvcjunction box. 23 supplying and erecting isi mark modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 25 supplying and erecting isi mark modular type switch 16 / 20 a with indicator, duly erected on provided plate and box with wiring connections complete. 26 supplying and erecting isi mark modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete. 27 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 28 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 29 supplying and erecting isi mark modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 30 supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. 31 supplying and erecting isi mark modular type blanking plate two module, duly erected on provided plate & box. 32 supplying and erecting pvc surface modular switch box with double mounting plate for 2 modules duly erected. 33 supplying and erecting pvc surface modular switch box with double mounting plate for 3 modules duly erected. 34 supplying and erecting pvc surface modular switch box with double mounting plate for 4 modules duly erected. 35 supplying and erecting pvc surface modular switch box with double mounting plate for 6 modules duly erected. 36 supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 modules complete duly connected. 37 supplying and erecting pvc surface modular switch box with double mounting plate for 12 modules duly erected. 38 supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. 39 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. 40 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match thebackground. 41 supplying and erecting 16 / 20 / 25 a starter ( modular range ) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 42 supplying and erecting isi mark modular type 5 pin socket with safety shutters 3 module socket 6a 240v ac supply, duly erected on provided plate and box with wiring connectionscomplete duly erected. 43 point wiring for light / fan / bell in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw / sw 44 point wiring for independent plug in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as perspecification no: wg pw / sw 45 point wiring for light / fan / bell concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm. ( 2+1e ) fr grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / cw 46 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg pw / sw 47 wiring for plug on board with switch socket, copper wiring and earthing as per specification no: wg pw / sw 48 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw / sw 49 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories as per specification no: wg pw / sw 50 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no:wg pw / sw 51 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 52 point wiring in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wgpw / sw 53 point wiring for independent plug in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 54 supplying & installing utp networking cat 6 cable suitable for lan / wan computer net working as per specification no wg coc / nc 55 dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no: wg dm / pw 56 dismantling the existing aluminium / copper mains, submains wiring upto 10 sq.mm. along with accessories etc complete as per specification no: wg dm / pw 57 supplying and erecting led square / circular 9 to 12w down lighter having pressure die cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 58 supplying and erecting led square / circular 13 to 15w down lighter having pressure die cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 59 supplying and erecting square / round shaped crca / diecast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13w to18w with provision for plane front frame with translucent cover fixed to the housing complete. 60 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housingcomplete. 61 supplying and erecting led flexible strip light 5m length upto 25w conforming ip 65 of any colour with driver complete. 62 supplying & erecting led 18w tube light fitting ( 4 feet ) with polycarbonate housing, heat sink, integrated hf electronic driver complete. 63 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 64 supplying and erecting electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and ( effective range upto 45 meter ) bell on 250 v a.c. supply. 65 supplying and erecting electronic type driver for indoor led upto 19w 24w fixtures suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 66 supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminiumalloy and heat sink extruded aluminium complete per specification no . fg odf / fls2. 67 supplying and erecting led flood light fitting of 50w, including lamp, with pf > 0.95, class ip 65 and above class ip 65 and above housing of pressure die cast aluminium alloy andheat sink extruded aluminium complete per specification no fg odf / fls 2 68 supplying and erecting recess mounted 20w led wall washers, tilted 70° outwards and swivels 360° to offer best illumination on the wall with any colour with driver complete. ( including compatible driver ) 69 supplying & erecting 20w led par ( 30 lamp e 27 base, spoto series ) lights by making necessary arrangement / recess in wall to make it flush with surface. 70 supplying and erecting cylindrical shaped integral decorative with high power 12w 16w led bollard upto 1000mm with opal acrylic diffuser and ip65 protection on provided foundation complete. 71 supplying and erecting mushroom shaped integral 12w 16w led decorative bollard upto 680mm with ip65 protection on provided foundation complete. 72 erecting the departmentally supplied wp led street light / flood light fitting upto 80w. 73 erecting departmentally supplied led street light / flood light fitting upto 150w . 74 erecting departmentally supplied led street light / flood light fitting upto 400w . 75 supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb 76 maintenance of non eesl led light of all wattages of approximately 500 quantity 77 maintenance of55 nos of street light switiching box 78 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 79 supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. 80 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 81 supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5metre length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. 82 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 83 supplying and erecting fresh air cum exhaust fan of light duty250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 84 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 85 supplying and erecting five star rated energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn / cf 86 supplying and erecting condenser 2.5 micro farad for ceiling fan 87 supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 88 providing recess in brick wall suitable forerection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. 89 providing recess in brick wall suitable forerection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 90 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaustfan of 300 mm as per specification no fg fas / msc 91 dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with accessories, g.i. down rod, frame etc. and making the site clear. 92 providing fully comprehensive annual maintenance service for 80 / 120 / 150 ltr. water cooler unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares including minor electrical parts within 48 hours. 4 ) refrigerant charging if required. 5 ) if failed to rectify the fault within 48 hrs penalty shall be charged rs.50 / per day.the job exclude sheet metal work and plastic material. 93 providing servicing of 1 / 1.5 / 2 / 3 tr capacitysplit / window air conditioning unit complete with allnecessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to engineer incharge. 94 providing annual comprehensive maintenance contract for 1.5 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 95 providing annual comprehensive maintenance contract for 2 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 96 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 1.5 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 97 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 2 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 98 providing replacement of unserviceable starting capacitor for a / c unit. 99 providing replacement of unserviceable running capacitor for a / c unit. 100 providing replacement of unserviceable fan motorcapacitor for a / c unit. 101 providing replacement of unserviceable pcb for a / c unit upto 3 tr capacity. 102 providing repair of of faulty pcb for air conditioning unit upto 3 tr capacity. 103 supplying and installing of new fan motor for condenser for air conditioning unit 104 providing vaccumising the airconditioner system and charging with r 22 refrigerant for air conditioning unit. 105 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 1.5tr window / split air conditioning unit. 106 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 2tr window / split air conditioning unit. 107 providing replacement of existing unserviceablecompressor of 150 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerent with guarantee for one year. 108 providing replacement of existing unserviceablecondensor coil of 40 / 80 / 150 litre cooling capacitywater cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 109 providing replacement of existing unserviceable ss water tap of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 110 providing replacement of existing unserviceable relay 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 111 providing replacement of existing unserviceablethermostat of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 112 dismantling the existing split type air conditionerof any type and capacity safely without any damages and making the site clear. 113 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / gi frame as per specification no. sw swr / mdp . 114 supplying and erecting double pole metal clad switch with hc type fuse 240v, 63a on iron / gi frame as per specification no. sw swr / mdp. 115 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specification no. sw swr / mtp. 116 supplying and erecting triple pole metal clad switch and fuse 415v, 100a on angle iron / gi frame as per specification no. sw swr / mtp. 117 supplying and erecting triple pole metal clad rewireable fuse switch 415v, 200a on angle iron / gi frame as per specification no. sw swr / mtp. 118 supplying and erecting four pole metal clad on load change over switch 415v, 100a erected on angle iron / gi frame complete. 119 supplying and erecting four pole metal clad on load change over switch 415v, 200a erected on angle iron / gi frame approved make complete. 120 supplying and erecting metal clad distribution board 240v, 8 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 121 supplying and erecting metal clad distribution board 240v, 6 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 122 supplying and erecting metal clad distribution board 240v, 4 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 123 supplying and erecting metal clad distribution board 415 v, 8 way, 32a. per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 124 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 125 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 126 supplying, erecting & marking spn mcb 6a to 32a, bseries ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 127 supplying, erecting & marking tpmcb 6 a to 32a in provided distribution board as per specification no. swswr / mcb 128 supplying, erecting & marking fpmcb 6a to 32a in provided distribution board as per specification no. sw swr / mcb 129 supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 130 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 131 supplying, erecting & marking tpn mcb 6a to 32a, c series in provided distribution board as per specification no. sw swr / mcb 132 supplying, erecting & marking tpn mcb 40a to 63a, c series in provided distribution board asper specification no. sw swr / mcb 133 supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 134 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 135 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 63a with required wiring connections and lugs etc. in provided distribution board complete. 136 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100a with required wiringconnections and lugs etc. in provided distribution board complete. 137 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board complete. 138 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63a in provided distribution board complete. 139 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 80 / 100a in provided distribution board complete. 140 supplying and erecting triple pole and neutraldistribution board ( tpndb ) surface / flushmounted suitable for spmcb of 12 poles on iron / gi frame ( horizontal busbar type ) as per specification no. swswr / mcbdb 141 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 142 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 143 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 144 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 145 supplying & erecting original 1.25 mm crca sheet metal enclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete erected on angle iron / gi frame. 146 supplying and erecting blanking plate of suitable size on mcb db complete. 147 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 16 / 25a complete as per specification no.sw rccb / rccb 148 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 149 providing, erecting and commissioning 4 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 150 providing, erecting & commissioning 4 pole rccb of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 100a, complete as per specification no. sw rccb / rccb 151 supplying & fixing crca sheet box with earthing terminals for housing 2 pole rccb on iron frame / laminated board complete. 152 supplying & fixing crca sheet box with earthing terminals for housing 4 pole rccb on iron frame / laminated board complete. 153 supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. 154 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 155 supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 156 supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 157 supplying and erecting gi sheet 1.6 mm ( 16 swg ) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for medium voltage installation. 158 supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions bythe authority. 159 supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 160 supplying, erecting & terminating xlpe armoured cable 3 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 161 supplying, erecting & terminating xlpe armoured cable 3 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 162 supplying, erecting & terminating xlpe armoured cable 3 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 163 supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 164 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 165 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in providedtrench / pipe as per specification no. cb lt / al 166 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 167 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / cu 168 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 169 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 90 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 170 supplying & erecting water tight terminal box of 1.6 mm ( 16 gauge ) crca sheet of size 200 x 150 x 150 mm. complete on pole as per specification no. cb sb 171 supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 172 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75 m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp 173 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 174 supplying and erecting pre stressed cement concrete ( psc ) rectangular pole of top 105 x 115 mm & bottom of 105 x 315 mm 9 m long ( 200 kg ) complete erected in provided c. c. foundation & muffing ( square / round ) as per specification no. oh pl / psc 175 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 176 supplying & erecting ms pole bracket, for oh conductor fabricated from ism channel, 75x40x6mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 177 supplying & erecting ms pole bracket, fabricated from ism channel, 75x40x6mm, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 178 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 179 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 180 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips , nuts and bolts, complete. 181 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length andpole clamps duly erected in provided cement concrete foundation. 182 supplying and erecting fibre / pvc spacers for lt overhead line 3 to 5 conductors complete erected. 183 supplying and erecting ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 184 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 185 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 186 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep 187 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 188 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 189 supplying and erecting aluminium strip of required sizes used for earthing on wall and / or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required.as per specification no ea ep. 190 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary giclamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no ea ep. 191 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit withscrews in an approved manner. 192 providing printed instruction chart for treating persons suffering from electric shock, printed in english & marathi and duly laminated complete. 193 supplying and fixing pvc synthetic elastomer electrically insulating mat with class a insulation conforming to is: 15652 – 2006 & cpri tested having 2 mm thickness upto 3.3 kv 194 supplying and fixing pvc synthetic elastomer electrically insulating mat with class b insulation conforming to is: 15652 – 2006 & cpri tested having 2.5 mm thickness upto 11 kv 195 supplying shock proof leather safety shoes of electrical grade of standard size as is :11226, 14544 duly tested, with necessary test certificate from manufacturer. 196 carrying out servicing of dg set upto 50 kva with / without amf panel of any make to ensure smooth running of dg set for 30 mins on load. checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. inspect alternator, stator and rotor for normal speed & proper frequency, examine batterycharging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking v belts with necessary adjustment, checking and retightening of nut bolts including coupling boltsof engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of avr, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, cleaning of dg set internally using blower, cleaning radiator and submit the servicing report to engineer in charge. ( non comprehensive ) as per specification no. gen ser amc 197 topping up new lubricating oil 15w / 40 grade of approved make as per is 13656 : 2014 198 topping up new glycol based coolant 50 / 50 with operating range from 118°c to 37°c of approved make 199 supplying and erecting v belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for dg set upto 100kva 200 supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for dg set upto 62.5 kva. 201 supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for dg set upto 50 kva. 202 supplying and erecting stop solenoid assembly 12v / 24v single coil energized to run with or without primary etc complete suitable for dg set upto 125 kva. 203 supplying and erecting air cleaner / air filter element suitable for dg set upto 40 kva 204 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 205 making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exnctr 206 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 207 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing andfinishing complete. ( above 6 m to 9 m poles ) 208 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 209 making m 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with thehelp of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 210 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. specification no cw ptg / ptp. 211 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 212 rewinding motor of the 1200 / 1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption withguarantee for one year. 213 replacing the existing ball bearing of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 214 replacing the existing bush / rubber, ring, washers of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 215 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c.. submersible / centrifugal pump set upto 2 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 216 supplying and installing 25 kva koel generators generator panel with 3 years warrenty. 217 doing rewinding and repairing cooling fan of 1400rmp 220v 218 doing repairing and fixing of thebroken main gate of 25 kva generator with required accessories. 219 supplying and installing fuel cap for 25 kva generator. 220 doing servicing of highmast ( upto 15 mtr ) with lowering of lights, cleaning ropes pathway lubricating the mechanisam with all necessary accessories. 221 supplying and erecting new rope in the highmast ( upto 15 mtr ) by dismantling highmast with proper equipments. 222 maintenance of 15 nos ofdecorative pole of 15w at park...

Central Railway - Maharashtra

37129448 supply of aluminium brushing, bright finishing faluminium brushing, bright finishing for general purpose to is:2339/1963 (reaffirmed 2009) packing in 4 ltrs duel container (alluminium paste packed in polyurethane bags and dipped in 4 ltr containers)aluminium brushing, bright finishing faluminium brushing, bright finishing for general purpose to is:2339/1963 (reaffirmed 2009) packing in 4 ltrs duel container (alluminium paste packed in polyurethane bags and dipped in 4 ltr containers),aluminum paint brushing, bright finishing for general purpose to is: 2339/2013 of make: alma, karbonn, asian, superlac, berger or similar. [ warranty period: 30 months after the date of delivery] [ warranty period: 30 months after the date of delivery ] => limited...

Directorate Of Municipal Administration - Maharashtra

37037704 annual maintenance contract of electrical department for indapur municipal council for year 2023 24 1 supplying & erecting mains with 2x10 sq.mmf.r copperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 2 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 3 supplying & erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw 4 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire. 5 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire 6 supplyinganderectingisi mark g.i. pipepole ‘b’ grade80 mm dia 6 m longwith pole cap, base plate in provided foundation as per specification no. oh pl / gip 7 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 8 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm diawith 4.5 x 3.65 x 3.25 mm thickness ( 5+2+2 m ) length respectively and total9 m long with pole cap, base plate in provided foundation ( weight 113 kg ) as perspecification no 9 providing & erecting 7 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 130 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 10 providing & erecting 9 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 155 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 11 providing and erecting galvanised 1000mm single arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 12 providing and erecting galvanised 1000mm double arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 13 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as perspecification no. oh pl / bkt 14 supplying and erecting g.i. pipe ‘c’ class erw 25 mm dia with necessary fittings complete as per specification no. 15 supplying and erecting g.i. pipe ‘c’ class erw 50 mm dia with necessaryfittings complet 16 supplyinganderectingpole clamp madefrom50 x 6 mmms flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 17 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea ep 18 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. ea ep 19 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per 20 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) 21 making m 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supplyof steel, concrete, excavation and fixing provided nut bolts with the help oftemplate, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) 22 making m 20 cement concrete foundation by considering the safe soilbearing capacity at site as 10 t / sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per designcomplete ( for 12.5 m raising lowering high mast ) 23 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp. 24 supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 25 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 26 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 27 supplying and erecting porcelain base iron clad cut out hc type 415v, 100aerected on polished wooden block. 28 supplying and erecting porcelain base iron clad cut out hc type 415v, 200aerected on polished wooden block 29 supplying, erecting & marking tpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 30 supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb 31 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 32 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 33 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 34 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 35 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 36 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / cu 37 supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supplyup to 7.5 h.p. 38 supplying & erecting fully automatic star / delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame 39 supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 40 supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 41 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 90 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 42 supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. cb cl / cu 43 supplying & erecting crimping type copper lugs for cable120 sq. mm. completeas per specification no. cb cl / cu 44 supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. ( meter pannel box ) 45 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw / hw 46 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing ncapping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories 47 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or anyother places. as per specification no: wg ma / bw 48 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 49 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 50 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation 51 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. 52 supplying and erecting integrated led street light fitting 23 to 25w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 2300 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3years warranty as per specification no fg odf / fls2. 53 supplying and erecting integrated led street light fitting 40 to 50w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3 years warranty as per specification no fg odf / fls2. 54 supplying and erecting integrated led street light fitting 70 75w ip65 & ik08class having single piece pressure die cast aluminium housing, having systemlumens output of min. 7700 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuiltsurge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including drivercomplete with 3 years warranty as per specification no fg odf / fls2. 55 supplying and erecting integrated led flood light fitting max. 70w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min. 8400 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2. 56 supplying and erecting integrated led flood light fitting max. 120w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min.14500 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2 57 erecting departmentally supplied led street light / flood light fitting above80 to 150w . 58 supplying and erecting street light bracket made from 40 mm. dia ‘b’ classg.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm diaduly welded with provided leads as per specification no. fg bkt / bpc 59 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 60 supplying and erecting electronic type driver for outdoor led fittings 151w 200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 61 supplying and erecting t8 fluorescent tube day light 600mm, 18 w 62 supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete &compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. 63 supplying and erecting flush type shockproof plug socket 6a & 16a ( 6 pin ) with 16a switch combined with indicator lamp and fuse with gang box onwooden board 64 supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete 65 supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e 27 base 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based oninsulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 67 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs.based on insulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 68 supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kva capacity online pure sine wave ups, with backup time of .......hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups 69 supplying and erecting 12v / 200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 70 supplying and erecting 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 71 providing servicing of 1 / 1.5 / 2 / 3 tr capacity split / window airconditioning unit with all necessary material. job includes checking ofperformance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to engineer incharge. 72 providing annual comprehensive maintenance contract for 1.5trsplit / window air conditioning unit complete as per terms and conditions. jobincludes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within24 hours 4 ) sending standby manpower for vip movement. the job exclude sheetmetal work and plastic material 73 providing brazing pipes and checking leakages in the split / window unitduly with dry nitrogen pressure, complete. 74 providing replacement of unserviceable pcb for ac unit upto 3tr capacity 75 supplying and erecting quartz electronic time switch having 24 hour dial towork on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteriesto run the time switch on failure of supply having switch contact rating up to 16ato use independently or in conjunction with contactor 76 supplying and erecting four pole power contactor 430 v, 40 a for time switchcomplete erected on provided wooden block / box, with necessary materials 77 supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “on” and switching“off” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit led continuous time display, relay output 230 v / 10a with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided m.s. box 78 supplying and erecting static energy meter with 240v 50 hz. ac supply 10to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring anddisplay kwh, kvah, v, i, pf, frequency, kw, kva, six months history ofenergy & md in kw & kva ) with transparent hinge type box completeerected on polished teak wood board duly wired with required size ofweather proof pvc wires duly tested by electric supply company 79 supplying & erecting crimping type aluminium lugs for cable 240 sq mmcomplete as per specification no. cb cl / al 80 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm.complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 81 supplying and erecting 3 phase 4 core 35 sq.mm. ( 3x35+1x25 ) aerial bunchedaluminium cable along with necessary accessories for lt distribution onprovided lt pole as per specification no. oh cbl / abc 82 supplying and erecting g.i. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, g.l. staywire 7 / 10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete 83 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level. 84 supplying and erecting of isi mark insulation tape 85 supplying and erecting of isi mark nutbolts 86 supplying and erecting of isi mark tester 87 supplying and erecting of isi mark led zero bulb 88 supplying and erecting of isi mark led zero bulb holder 89 supplying and erecting fault clearing on street light conductor 90 supplying and erecting of ac servicing 91 supplying and erecting of filter servicing 92 supplying and erecting of batery servicing with water change 93 supplying and erecting of ro membrane for filter 94 supplying and erecting isi mark extension box...