40784876
tender for electrification jobs of block no 114 at inrp site, tarapur; 1 supply, installation, testing and commissioning of following configuration415v, 3 phase, 4 wire, double door, with r y b phase indication and mcb position indication through glass front, ip 54, prewired with hffr copper wires, horizontal type, metallic double door, phase segregated three pole and neutral mcb distribution board fabricated out of 2 mm thick , powder coated with ral7032 shade , pre galvanised g.i. sheet steel, suitable for surface mounting / installation in existing enclosure complete with appropriate rating of tinned copper bus bar / cu wire, neutral bus bar, earth bar, din bar, brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant is & as per instructions of engineer in charge. 2 8 way having 1 no. main incomer of 40a tpn mcb, isc=10ka, type c with 1 no. of40a, isc=10ka, dp, rcbo ( 100ma ) as incomer for each phase and 24 nos. outgoing of 6a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 3 supply 4 installation, testing and commissioning 5 6 way having 1 no. main incomer of 40a tpn mcb, isc=10ka, type c with 1 no. 40a, isc=10ka, dp, rcbo ( 100ma ) as incomer for each phase and 18 nos. outgoing of 16a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 6 supply 7 installation, testing and commissioning 8 6 way having 1 no. main incomer of 32a tpn mcb, isc=10ka, type c with 1 no. 32a, isc=10ka, dp, rcbo ( 100ma ) as incomer for each phase and 18 nos. outgoing of 16a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 9 supply 10 installation, testing and commissioning 11 4 way having 1 no. main incomer of 32a tpn mcb, isc=10ka, type c with 1 no. 32a, isc=10ka, dp, rcbo ( 100ma ) as incomer for each phase and 12 nos. outgoing of 16a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 12 supply 13 installation, testing and commissioning 14 4 way having 1 no. main incomer of 25a tpn mcb, isc=10ka, type c with1 no. 25a, isc=10ka, dp, rcbo ( 100ma ) as incomer for each phase and 12 nos. outgoing of 6a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 15 supply 16 installation, testing and commissioning 17 supply, installation, testing and commissioning of following configuration 240v, 1 phase, 2 wire, withphase and mcb position indication through glass front, prewired with hffr copper wires, ip 54, mcb distribution board fabricated out of 2mm thickpre galvanised g. i sheet steel, powder coated with ral7035 shade, suitable for surface mounting / installation in existing enclosure complete with appropriate rating of tinned copper bus bar / cu wire, neutral bus bar , brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, earth bar, din bar for mcb mounting, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, check nuts etc. as required as per drawing, specifications & generally as per relevant is & as per instructions of engineer in charge. 18 12 way having 1 no. main incomer of 25a dp rcbo ( 100ma ) , isc=10ka, type c and 12 nos. outgoing of 16a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 19 supply 20 installation, testing and commissioning 21 8 way having 1 no. main incomer of 16a dp rcbo ( 100ma ) , isc=10ka, type c and 8 nos. outgoing of 6a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 22 supply 23 installation, testing and commissioning 24 4 way having 1 no. main incomer of 16a dp rcbo ( 100ma ) , isc=10ka, type c and 4 nos. outgoing of 6a spn mcb. suitable for 240v rating, type c curve, 10 ka breaking capacity and as per tender technical specifications. 25 supply 26 installation, testing and commissioning 27 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, industrial box type, surface mounted 4ft fixture along with two nos. of 18w, 2350 lm, minimum 130 lm / w efficacy, cct 6500k and cri>80, thd<10%, pf>0.95, 4ftled tube. the luminaire shall meet ip20 rating. the fixture shall have single piece construction made of white powder coated crca sheet steel suitable for above led tube light. the led shall be mounted on extruded aluminium strip which acts as heat sink and is integral part of tube which is made up of extruded poly carboante material which gives diffused light. the total power consumption should not exceed 38w ( including driver ) . 28 supply 29 installation, testing and commissioning 30 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led highbay with a nominal system lumen output of 16500 lumens and a minimum system efficacy of 125 lm / w. the luminaire shall have a rated system lifetime of 50, 000 burning hours at l70. the luminaire should have a cct of 6500k and cri > 80 and sdcm<5. the luminaire shall meet ip66rating with thd < 10% and pf > 0.95 and in built surge protection of 4kv.the luminaire housing should made of high pressure die cast aluminium with wide beam optics and having gasket of heat proof siliconerubber ring. the total power consumption should not exceed 132w ( including driver ) . 31 supply 32 installation, testing and commissioning 33 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led peripheral luminaire with a nominal system lumen output of 11000 lumens and a minimum system efficacy of not less than 120 lumen / watt. the luminaire should have cct 5700k and a cri>70. the luminaire shall meet ip66, ik 07 rating with thd<10% & pf=0.95 or more. the luminaire housing should be made of pressure die cast aluminium. the total power consumption should not exceed 90w ( including driver ) . 34 supply 35 installation, testing and commissioning 36 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led bulkhead with a nominal system lumen output of 11000 lumens and a minimum system efficacy of 110 lm / w. the luminaire should have a cct of 6500k and cri > 70. the luminaire shall meet ip66 rating and ik 09 rating with thd < 20% and pf > 0.9. the luminaire housing should made of high pressure die cast aluminium with high quality pmma diffuser. the total power consumption should not exceed 10w ( including driver ) . 37 supply 38 installation, testing and commissioning 39 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, linear 4ft, 40w led tube with a nominal system lumen output of 5000 lumens and a minimum system efficacy not less than 125lm / w.the luminaire should have a cct of 6500k and cri>80. the luminaire shall meet ip 65 rating with thd < 10% and pf > 0.95. the luminaire housing should be made of polycarbonate. mounting accessories shall be ofstainless steel . the total power consumption should not exceed 40w ( including driver ) . 40 supply 41 installation, testing and commissioning 42 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led 4ft slim batten ( 75mm x 95mm x 1122mm ) with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 130 lm / w.the luminaire should have a cct of 6500k and cri>80. the luminaire shall meet ip20 rating with thd < 10% and pf > 0.95. the luminaire housing should made of extruded aluminium with extruded pc diffuser & should have anodised finish. the total power consumption should not exceed 19w ( including driver ) . 43 supply 44 installation, testing and commissioning 45 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led surface type sleek downlighter with a nomial system lumen output of 1500 lumens and a minimum system efficacy of not less than 110lm / w. the luminaire should have a cct of 6500k and cri>80. the luminaire shall meet ip20 rating with thd<30% and pf >0.9. the luminaire housing should made of polycarbonate with high efficiency diffuser. the total power consumption should not exceed 15w ( including driver ) . 46 supply 47 installation, testing and commissioning 48 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led peripheral luminaire with a nominal system lumen output of 5400 lumens and a minimum system efficacy of not less than 120 lumen / watt. the luminaire should have cct of 5700k and a cri>70. the luminaire shall meet ip20, ik 08 rating with thd<10% & pf>0.9. the luminaire housing should be made of pressure die cast aluminium. the total power consumption should not exceed 45w ( including driver ) . 49 supply 50 installation, testing and commissioning 51 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led highbay with a nominal system lumen output of 15000 lumens and a minimum system efficacy of not less than 160 lm / w. the luminaire shall have a rated system lifetime of 50, 000 burning hours at l70. the luminaire should have a cct of 5700k and cri > 70 and sdcm<5. the luminaire shall meet ip66 and ik 08 rating with thd < 10% and pf > 0.95 and in built surge protection of 4kv. the luminaire should be tested from nabl accredated lab and should have proper ies file. the luminaire housing should made of high pressure die cast aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. the total power consumption should not exceed 90w ( including driver ) . 52 supply 53 installation, testing and commissioning 54 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, 2x36 w, 240v, 50hz, ftl flame proof industrial luminaire suitable for wall mounting complete with heat resistant glass cover, low loss copper ballast, capacitor, lamp, 2nos. cable entry nipple, wiring, etc. 55 supply 56 installation, testing and commissioning 57 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led integral driver flood light with a nominal system lumen output of 10, 000 lumens and a minimum system efficacy of 140 lumen / watt. the luminaire should have a cct of 5700kand a cri>70. the luminaire shall meet ip66 rating with thd<20% & pf>0.9. the luminaire housing should be made of pressure die cast aluminium. the total power consumption should not exceed 72w ( including driver ) . 58 supply 59 installation, testing and commissioning 60 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led recessed 2ft x 2ft luminaire with a nomial system lumen output of at least 4000 lumens and a minimum system efficacy of 125 lm / w. the luminaire should have a cct of 5700k and cri>80. the luminaire shall meet ip20 rating with thd<5% and pf >0.95, ugr<16% & sdcm <= 4. the luminaire housing should made of powder coated metallic crca with high efficiency opal diffuser. the total power consumption should not exceed 36w ( including driver ) . 61 supply 62 installation, testing and commissioning 63 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led integral driver flood light with a nominal system lumen output of 7000 lumens and a minimum system efficacy of 100 lumen / watt. the luminaire should have cct of 6500k and a cri>70. the luminaire shall meet ip66 rating with thd<20% & pf>0.9. the luminaire housing should be made of pressure die cast aluminium. the total power consumption should not exceed 72w ( including driver ) . 64 supply 65 installation, testing and commissioning 66 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led integral driver, recess mount 2x2 grid light of 36w having system efficacy of 125 lm / w with ugr<16, system output of 4000 lumens for 36w, thd <10%, power factor >0.95, cri >80, cct 6500k, body made of crca housing having ps diffuser, life l70b50 @ 50k hrs. bis compliantdriver. driver shall have 2.5kv surge protection. 67 supply 68 installation, testing and commissioning 69 sitc ofled light fittings complete withlight fitting accessories, includingsupply of fixing ss accessories, flexible gi metallic conduit sleeves, pvc conduit bushes, cu cable lugs, led integral driver, recess mount circular down light fitting of 19w with ugr<19 having system efficacy >110 lm / w, system output of 2000 lumens, thd <10%, power factor >0.95, cri >80, cct 4000k, body made of piece die cast aluminium housing having specially designed prismatic diffuser for soft glare free light, life l70b50 @ 50k hrs. bis compliantdriver. driver shall have 2.5kv surge protection. 70 supply 71 installation, testing and commissioning 72 supply and installation of the following mcb and plug sockets with suitable plug tops ( 3 pin ) in the exisitng recess mounted gi boxand 3 pin domestic plug sockets with suitable polycarbonate box, face plate, switch and plug tops as per technical specifications. 73 1 no. of 6a, single phase industrial socket withtype c curve, industrial type mcb, isc=10ka, along with pre powder coated gi sheet steel face plate, industrial plug tops and suitable din rail and mounting arrangements as per technical specification. 74 supply 75 installation, testing and commissioning 76 1 no of 6a and 1 no of 16a, single phase modular decorative type socket with polycarbonate box, switch for each socket and heavy duty polycarbonate face plate, plug topsand suitable mounting arrangements as per technical specification. 77 supply 78 installation, testing and commissioning 79 1 no of 16a, single phase modular decorative type socket with polycarbonate box, switch for each socket and heavy duty polycarbonate face plate, plug topsand suitable mounting arrangements as per technical specification. 80 supply 81 installation, testing and commissioning 82 2 nos. of 6a, single phase industrial socket with type c curve, industrial type mcb, isc=10kaalong with pre powder coated gi sheet steel face plate, industrial plug tops and suitable din rail and mounting arrangements as per technical specification. 83 supply 84 installation, testing and commissioning 85 2 nos. of 6a, single phase industrial socket with type c curve, industrial type mcb, isc=10kaalong with pre powder coated gi sheet steel face plate, industrial plug tops and suitable din rail and mounting arrangements as per technical specification. 86 supply 87 installation, testing and commissioning 88 supply and installation of the following mcb with face plate ( in the existing recess mounted gi box ) and decorative switches with polycarbonate box and face plate as per technical specifications. 89 1 nos. of 6a, single pole, isc=10ka, type c curve, mcbalong with pre galvanised powder coated gi sheet steel face plate and suitable din rail and mounting arrangements as per technical specification. 90 supply 91 installation, testing and commissioning 92 2 nos. of 6a, single pole, isc=10ka, type c curve, mcb along with pre galvanised powder coated gi sheet steel face plate and suitable din rail and mounting arrangements as per technical specification. 93 supply 94 installation, testing and commissioning 95 3 nos. of 6a, single pole, isc=10ka, type c curve, mcbalong with pre galvanised powder coated gi sheet steel face plate and suitable din rail and mounting arrangements as per technical specification. 96 supply 97 installation, testing and commissioning 98 4 nos. of 6a, single pole, isc=10ka, type c curve, mcbalong with pre galvanised powder coated gi sheet steel face plate and suitable din rail and mounting arrangements as per technical specification. 99 supply 100 installation, testing and commissioning 101 1 nos. of 6a, single pole, modular type decorative switch with polycarbonate box, heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. 102 supply 103 installation, testing and commissioning 104 2 nos. of 6a, single pole, modular type decorative switch with polycarbonate box, heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. 105 supply 106 installation, testing and commissioning 107 3 nos. of 6a, single pole, modular type decorative switch with polycarbonate box, heavy duty polycarbonate face plate and suitable mounting arrangements as per technical specification. 108 supply 109 installation, testing and commissioning 110 supply and fixing of heavy duty class b galvanised steel ( g.i. ) erw conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, cleating with heavy duty gi saddles or suit to site clamps on rcc wall, column, steel structural, etc. as required under the instruction of engineer in incharge. surface type junction box shall be provided. 111 25 mm 112 40 mm 113 supply and laying of 14 swg tinned solid copper conductor throughout along the conduit including fixing with ties, brazing etc as required. 114 supply 115 installation, testing and commissioning 116 supply of single core hffr wires ( copper ) of size mentioned below in voltage grade 1100 v as per the is 17048: 2018 ( latest edition ) and as per conductor class 2 of is: 8130 / 1984 as per technical specification 117 1.5 sq. mm 118 2.5 sq. mm 119 installation / drawing through concealled / surface conduit and wiring and termination at both ends of single core hffr wires ( copper ) of size mentioned below in voltage grade 1100 v as per the is 17048 : 2018.as per conductor class 2 of is: 8130 / 1984 as per technical specification 120 1.5 sq. mm 121 2.5 sq. mm 122 junction box / cable pull box ip64 shall be weather proof type, fabricated out of 2 mm thick gi sheet, cable gland plate at the bottom, suitable to terminate 2 nos. of 3 core x 2.5 sq. mm cu cable, 8 nos of terminals, etc as required. 123 supply 124 installation 125 supply, fabrication and installation of standard steel sections as per is 2062 grade br for cable tray supports including gi rod for cable tray support, chequered plates for trench covers, base framesfor panels, anchor fasters, wall frames and brackets for supporting equipment. fabrication shall include drilling, entiling, welding wire brush cleaning, testing dpt etc , supply of all consumables like gas, approved make welding rods as per tender tech spec. after fabrication two coats ofepoxy based primer and two coats of finish paints shall be applied 126 supply 127 installation 128 supply, installation and commissioning ofcopper earth plate 600 mm x 600 mm x 3.15 mm thick of high grade quality including accessories and providing civil masonry pit andenclosure with gi cover plate having locking arrangement and watering pipe of 2.7 metre length with charcoal / coke and salt as per is 3043 standard as per attached technical specification. 129 supply 130 installation, testing and commissioning 131 supply and laying of 95 sq. mm class 2 stranded tinned copper conductor in rcc trench / underground upto depth of 1 meter, connection with earth pit at one end and conductor tail at other end, including clamping, brazing, connection etc. as per instructions by engineer in charge. 132 supply 133 installation 134 supply and surface / concealed laying of 10 sq. mm tinned coper conductor, connection with earth pad at one end and dbs at other end clamping, brazing etc. as per instructions by engineer in charge. 135 supply 136 installation 137 supply and surface / concealed laying of 6 sq. mm tinned coper conductor, connection with earth pad at one endand motor, other equipment, etc. at other end clamping, brazing etc. as per instructions by engineer in charge. 138 supply 139 installation and testing 140 supply and surface / concealed laying of 4 sq. mm tinned coper conductor, connection with earth pad at one endand motor, other equipment, etc. at other end clamping, brazing etc. as per instructions by engineer in charge. 141 supply 142 installation and testing 143 supply and installation of test link box for earth pit connection and interconnection of down conductor from lightning protection system to lightning earth pit and should consist of 2mm thick powder coated pre galvanised g.i. weather proof sheet enclosure with cover, having 50mm x 3mm copper strip link, teflon sealing after connection, earthing stud, etc as required. 144 supply 145 installation and testing 146 supply and installation of 25 mm x 3 mm thick copper strip including connection / terminating with nut, bolt, spring, washer etc. as required. 147 supply 148 installation, testing 149 supply and fixing of 25mm x 6mm gi strip along tray using suitable size gi saddel / clamp including interconnection, hardwares, etc as required . 150 supply 151 installation and testing 152 supply and laying of 2 x 10sq. mm cu pvc insulated earthing conductor in 40mm hdpe pipe on surface / existing concealed including clamping / cleating on wall, making chase, repairing the same, etc as required. 153 supply 154 installation and testing 155 supply of 40 mm, 6kg / m² hdpe pipe as per attached specifications. 156 supply of tinned cu lugs as per attached technical specification 157 16sqmm stranded bare tinned copper conductor 158 10sqmm stranded bare tinned copper conductor 159 6sqmm stranded bare tinned copper conductor 160 4sqmm stranded bare tinned copper conductor 161 2.5sqmm stranded bare tinned copper conductor 162 14swg solid bare tinned copper conductor 163 end termination of pvc insulated copper conductor, of following sizesas required. 164 16sqmm stranded bare tinned copper conductor 165 10sqmm stranded bare tinned copper conductor 166 6sqmm stranded bare tinned copper conductor 167 4sqmm stranded bare tinned copper conductor 168 2.5sqmm stranded bare tinned copper conductor 169 14swg solid bare tinned copper conductor 170 sitc of 4 tr ( not less than 48000btu / hr ) , cassette air conditioners 3 phase, 415v cassette type split a.c. units ( eer shall not be less than 3.00 ) , sound level of indoor unit 55db maximum, refrigerant r 410a or r 22 or non cfc, complete with all components like indoor unit cooling coil, centrifugal type fan including pumping of water, outdoor unit ( air cooled condenser ) comprising of condenser coil scroll type compressor, condensor motor etc controls, interlocking, electrical accessories etc as required for proper functioning of cassette unit controlled by cordless lcd remote complete suitable for operation on 415 volts + / 10%, 50 hzs a.c. supply etc. capable of performing functions like cooling, dehumidifying, air circulating, filtering etc complete as reqd as per technical specifications attached. note condenser coil tube and evaporator coil tube shall be made from copper of high quality grade. 171 supply 172 installation, testing and commissioning 173 supply and fixing vertical air termination made up of 20mm dia, 1 mtr long copper rod attached to 145 mm dia. copper sphere having drilled and tapped holes for fixing 5 nos. of 390mm long spikes and square copper base plate of 150 mm length and 10 mm thickness as per technical specification and approved drawing. 174 supply 175 installation and testing 176 supply, installation and commissioning of copper earthing rod with 25mm diameter and 3000mm long including accessories, and providing pcc enclosure with cover plate hot dip galvanised having lifting lug and locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as per is 3043 standard, technicals specification and drawing 177 supply 178 installation 179 junction box / cable pull box fabricated out of 2 mm thick gi sheet steel, punched hole for conduit entry on all sides, 6 nos of terminals of 4sqmm, etc as required. 180 supply 181 installation 182 junction box / cable pull box fabricated out of 2 mm thick gi sheet steel, punched hole for conduit entry on all sides, 8 nos of terminals of 4sqmm, etc as required. 183 supply 184 installation 185 prefabricted gi box to accomodate modular type 2 nos. of rj11 socket unit suitable for concealing or surface mounting. 186 front plate of modular type to accommodate 2 nos. ofrj11 socket unit. 187 supply of wheather proof type brass double compression glands and bimetallic lugs for xlpe 1.1 kv grade al / cu cable of following sizes as per attached technical specifications. 188 3.5 core x 240sqmm, al conductor 189 2 core x 50sqmm, cu conductor 190 2 core x 10sqmm, cu conductor 191 2 core x 4sqmm, cu conductor 192 3 core x 16sqmm, cu conductor 193 3 core x 10sqmm, cu conductor 194 3 core x 6sqmm, cu conductor 195 3 core x 4sqmm, cu conductor 196 3 core x 2.5sqmm, cu conductor 197 3.5 core x 50sqmm, cu conductor 198 3.5 core x 35sqmm, cu conductor 199 3.5 core x 25sqmm, cu conductor 200 4 core x 25sqmm, cu conductor 201 4 core x 16sqmm, cu conductor 202 4 core x 10sqmm, cu conductor 203 4 core x 6sqmm, cu conductor 204 4 core x 4sqmm, cu conductor 205 4 core x 2.5sqmm, cu conductor 206 glanding and end termination of lt cables of following sizesas required. 207 3.5 core x 240sqmm, al conductor 208 2 core x 50sqmm, cu conductor 209 2 core x 10sqmm, cu conductor 210 2 core x 4sqmm, cu conductor 211 3 core x 16sqmm, cu conductor 212 3 core x 10sqmm, cu conductor 213 3 core x 6sqmm, cu conductor 214 3 core x 4sqmm, cu conductor 215 3 core x 2.5sqmm, cu conductor 216 3.5 core x 50sqmm, cu conductor 217 3.5 core x 35sqmm, cu conductor 218 3.5 core x 25sqmm, cu conductor 219 4 core x 25sqmm, cu conductor 220 4 core x 16sqmm, cu conductor 221 4 core x 10sqmm, cu conductor 222 4 core x 6sqmm, cu conductor 223 4 core x 4sqmm, cu conductor 224 4 core x 2.5sqmm, cu conductor 225 supply and installation of brass double compression glands and pvc shroud and crimping type tinned copper lugs for 12 core x 2.5sqmm size of xlpe insulated frls pvc sheathed copper conductor control cable of 0.65kv garde. 226 supply 227 installation 228 supply and installation of hot dip galvanised ladder type cable tray fabricated out of 2.5mm thick sheet steel having 300mm width, side channel of 100mm, rungs spaced at 250mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover and all suitable accessories ( couplers / tees / bends / cross member / connectors, nuts and bolts ) as per attached technical specification. 229 supply 230 installation 231 supply and installation of hot dip galvanised ladder type cable tray fabricated out of 2.5mm thick sheet steel having 150 mm width, side channel of 100mm, rungs spaced at 250mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover and all suitable accessories ( couplers / tees / bends / cross member / connectors, nuts and bolts ) as per attached technical specification. 232 supply 233 installation 234 supply and installation of hot dip galvanised perforated type cable tray fabricated out of 2.5mm thick sheet steel having 300 mm width, side channel of 100mm, cross perforation not more than 17.5%, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover and all suitable accessories ( couplers / tees / bends / cross member / connectors, nuts and bolts ) as per attached technical specification. 235 supply 236 installation 237 sitc of split air conditioning unit of 2.0 tr capacity i.e. with cooling capacity not less than 5200 watt complete with outdoor condensing unit & wall mounted evaporating unit having cordless remote control refrigerant pipe line upto 10 meter length, capable of cooling, filtering & dehumidifying, suitable for operation on 230 volt1=ph.ac supply ( not less than five star rating model as certified by bee ) with mountings, / fittings for indoor / outdoor units, insulating the suction pipe with epf tubing, leak test, charging refrigerant including providing electrical wires and plug top with in 4 meter of location of unit etc complete as reqd as per technical specifications attached. 238 supply 239 installation, testing and commissioning 240 supply and installation of hot dip galvanised perforated type cable tray fabricated out of 2.5mm thick sheet steel having 150 mm width, side channel of 100mm, cross perforation not more than 17.5%, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover and all suitable accessories ( couplers / tees / bends / cross member / connectors, nuts and bolts ) as per attached technical specification. 241 supply 242 installation 243 supply and installation of ladder type frp cable tray of following size having min 5mm thick, side channel of 100mm and rungs spaced at not more than 250mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover and all suitable accessories ( couplers / tees / bends / cross member / connectors, nuts and bolts ) as per attached technical specification. 244 600mm wide 245 supply 246 installation 247 450mm wide 248 supply 249 installation 250 300mm wide 251 supply 252 installation 253 supply and installation of ladder type frp cable tray of 150mm width min 5mm thick, side channel of 50mm and rungs spaced at not more than 250mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustment with dome type cover ( min 3mm thick ) and all suitable accessories ( couplers / tees / bends / cross member / clampig with cable tray / connectors, nuts and bolts ) as per attached technical specification. 254 supply 255 installation 256 supply and installation of perforated type frp cable tray of 300mm width having min 5mm thick frp sheet with channel of 100mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustmentwith dome type cover and all suitable accessories ( couplers / tees / bends / cross member / clampig with cable tray / connectors, nuts and bolts ) as per attached technical specification. 257 supply 258 installation 259 supply and installation of perforated type frp cable tray of 150mm width having min 5mm thick frp sheet with channel of 100mm, single length not less than 2.5mtr with two coupling / joint plates per tray length having one long grove for adjustmentwith dome type cover and all suitable accessories ( couplers / tees / bends / cross member / clampig with cable tray / connectors, nuts and bolts ) as per attached technical specification. 260 supply 261 installation 262 supply and fixing of water based fire stop / fire barrier with min 3 hr fire rating for cable opening and suitable for retrofitting along with fire sealant, making frames, finishing, etc as required 263 supply and fixing of fire retardent cable coating paint with min 30min fire rating for horizontal and vertical cable runs 264 supply and installation of 20 kva online ups ( 3 phase input and single phase output ) with 12v smf lead acid battery bank along with independent battery rack to provide minimum 1 hour total backup at full load. 265 supply 266 installation, testing and commissioning 267 supply & installation of high back patterned mesh back chair. seat size 760mm ( w ) x 760 mm ( d ) 990 1100 mm ( h ) . mechanism should have following features: 360 degree revolving, two seat depth, mesh upholstery on back, nylon pedestal etc. 268 supply and installation of mineral fibre ceiling tile of dimension 595x595mm with 16 mmthickness and associted gi frame work as per the tender tech specs 269 supply 270 installation 271 supply, fabrication & installation of workstation housing cabinet as per technical specification. 272 installation, testing and commissioning of ( emldp ) emergency main lighting distribution panel with 63 amp tp mccb incomer and 6 nos. oftpn mccb ougoing feeders and as per attached sld dwg. no. ip1 / 114 / 05097339 / dwg / 002 / r0 273 installation, testing and commissioning of ( empdp ) emergency main power distribution panel with two numbers of 250 amp 4p mccbincomer ( with mechanical and elecrtical interlock ) and 13 nos. tpn mccb outgoing feeder and as per attached sld dwg. no. ip1 / 114 / 05097339 / dwg / 001 / r0 274 installation, testing and commissioning of normal motor control centre with one no. of 100 a microprocessor based 4p mccb incomer and 14 nos. 1.1kw rated dol starter outgoing feeders and as per attached sld dwg. no.ip1 / 114 / 05097339 / dwg / 001 / r0 275 installation, testing and commissioning of normal motor control centre with one no. of 400 a microprocessor based 4p mccb incomer and total 30 nos. of outgoing feeders having dol starters and tpn mccband as per attached sld dwg. no.ip1 / 114 / 05037339 / dwg / 002 / r0 276 installation, testing and commissioning of normal motor control centre with one no. of 100 a microprocessor based 4p mccb incomer and 14 nos. 1.1kw rated dol starter outgoing feeders and as per attached sld dwg. no.ip1 / 114 / 05097339 / dwg / 005 / r0 277 installation, testing and commissioning of normal motor control centre with one no. of 400 a microprocessor based 4p mccb incomer and total 30 nos. of outgoing feeders having dol starters and tpn mccband as per attached sld dwg. no.ip1 / 114 / 05037339 / dwg / 003 / r0 278 installation, testing and commissioning of ( nmldp ) nrmal main lighting distribution panel with 100 amp tp mccb incomer and 6 nos. of32 a tpn mccb ougoing feeders and as per attached sld dwg. no. ip1 / 114 / 05097339 / dwg / 001 / r0 279 sitc of bladless tower fan suitable for operating at 240v ac with 3 speed levels, airflow of 2230 m3 / h, power consumption of 40 w, max noise level of 50 db, touchsreen panel with remote control and minimum 2 years of warranty. 280 supply 281 installation, testing and commissioning 282 installation, testing and commissioning of ( nmpdp ) normal main power distribution panel with two numbers of 630 amp 4p microprocessor based mccbincomerand 21 nos. total outgoing feeders having tpn mccband dol starters as per attached sld dwg. no. ip1 / 114 / 05037339 / dwg / 001 / r0 283 installation, testing and commissioning of ( upspdp ) ups power distribution panel with one number of 125 amp dp mccbincomerand 10 nos. total outgoing feeders having dp mccb as per attached sld dwg. no. ip1 / 114 / 05057339 / dwg / 001 / r0 284 installation, testing and commissioning of ( upspdp ) ups power distribution panel with one number of 125 amp dp mccbincomerand 10 nos. total outgoing feeders having dp mccb as per attached sld dwg. no. ip1 / 114 / 05057339 / dwg / 002 / r0 285 laying and dressing of following size cables on surface including clamping / cleating on structure / floor / ceiling / wall / tray / conduit interconnection through bolting, etc as required. 286 power cable ( a2xwy ( p ) ) of size 3.5c x 300 sq.mm, aluminium conductor, armoured, 1.1 kv grade 287 power cable ( a2xwy ( p ) ) of size 3.5c x 240 sq.mm, aluminium conductor, armoured, 1.1 kv grade 288 power cable ( a2xwy ( p ) ) of size 3.5c x 50 sq.mm, aluminium conductor, armoured, 1.1 kv grade 289 power cable ( a2xwy ( p ) ) of size 3.5c x 35 sq.mm, aluminium conductor, armoured, 1.1 kv grade 290 power cable ( 2xwy ( p ) ) of size 4c x4 sq.mm, annealed copper conductor, armoured, 1.1 kv grade 291 power cable ( 2xwy ( p ) ) of size 4c x 10 sq.mm, annealed copper conductor, armoured, 1.1 kv grade 292 power cable ( 2xwy ( p ) ) of size 3c x2.5 sq.mm, annealed copper conductor, armoured, 1.1 kv 293 3c x 2.5 sq.mm, 1.1kv grade, multi strand, flexible copper cables, pvc insulated, frls pvc st2 outer sheathed, conforming to latest version ofis 694 and as per the tender technical specifications 294 supply and installation of gi anchor fastner of size m12x150 mmby drilling through concrete block as per site requirement for fixing plate eps or other structures as per the tender tech spec 295 supply 296 installation, testing and commissioning 297 supply and installation of gi anchor fastner of size m16x150 mmby drilling through concrete block as per site requirement for fixing plate eps or other structures as per the tender tech spec 298 supply 299 installation, testing and commissioning 300 supply and installation hot dip galvanized finish rods, threaded all the way down and chamfered at each end of lengths and dia suit to site requirement with bottom hot dip galvanized cable tray support complete with all the nuts, washer etc as required as per tender tech spec 301 sitc of three phase heavy duty exhaust fan of sweep 600 mm with frp duct, sturdy metal body, high efficiency capacitor type motor with double ball bearing, dynamically balanced blade for better performance and a corrosion resistant powder coated metallic finish.three phase heavy duty exhaust fan of sweep 600 mm with frp duct suitable for industrial application. 302 supply 303 installation, testing and commissioning 304 making the opening in brick masonry for door / window / clear story opening including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface including disposal of mulba / rubbish to the nearest dumping ground. 305 excavation in all type of soils to a depth of 1000 mm below ground level, sand bedding, laying of rcc tiles, baked bricks on side and top, back filling, dewatering ( if necessary ) , consolidation shoring, disposal of excess earth.item includes supply of crush sand and class 1 bricks....
Due Date : December 26, 2023
Tender Value : ₹ 2.64 Crore