Rural Development Department - Maharashtra

37856896 supply of electrical and electronic materials in the financial year 2023 24 at grampanchayat. hinjawadi. supply of electrical and electronic materials in the financial year 2023 24 at grampanchayat hinjawadi. , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) , supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation (weight 175 kg.) as per specification no. . oh pl/stp , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying,tpmcb 40a to 63a in provided distribution board , providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf/fls 2 , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , street light pole box frp , cement street light pole clamp , m.s. street light pole clamp , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor , 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor , 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor , 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor , 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series (for lighting) in provided distribution board as per specification no. swswr/ mcb , 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series (for lighting) in provided distribution board as per specification no. swswr/ mcb , 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions (i o ii) with centre off position as per specification no. sw swr/mcbcos , 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr/mcbcos , 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl/cu , 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl/cu , 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl/cu , 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting icdp switch 10a to 63a , cable joint kit for armoured cable 20 upto 120sq. mm cable , gi tar for service wire support with bobine. , kit kat type fuse 16a 32a 63a 120a , taparia tester , spaner set , control panel hrc fuse , supplying and erecting transformer fidder piller , 5 2 19 supplying & erecting street light control panel in powder coated crca 14/16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , shakal insulator , shakal nut bolt nos , cores arm clamps , 2 pin angel , conductor o2 , conductor gnat , moter starters 3 phase. , switch & socket 6a 16a , moter starters 1 phase , 10 sq mm 3 corealuminum cabal. , celling fan 1200mm , wall fan. 400mm , pop led light 30 40.w , angel holder , led bulb 0 50 w. , 12 model gang box vinay adora , 6amp socket vinay adora , 6amp switch vinay adora , 18 model gang box vinay adora , 16amp socket vinay adora , 16amp switch vinay adora , 2.5sq mm wire 90mtr , 1.5sq mm wire 90mtr , 1sq mm wire 90mtr , casing paty 1 , 35x8 pvc rawal plug , 6x19 drywall screw pop , 6amp socket vinay adora , 6amp switch vinay adora , dummy plate vinay adora , 12 model gang box vinay adora , drill machine bosh , star bit , insulation tape box , dp switch , wire striper , l&t 1 phase contactor , l&t 3 phase contactor , 1 phase timer , 10 sq.mmaluminium lugs 100 nos(1 pkt) , wire striper , bend pipe with fittings , 1 1/2 nut bolt 1 kg , o/l relay l&t make,mn2 , dcm & acm tong testermeco model 27 auto , office bell , conntinuty tester , extension box oreva make , digital timer switch(l&t) , steelgrip tap 6.5mtr , water proof tep , 6x13 drywall screw pop , 6x19 drywall screw pop , 10mm alluminiam lugs , 16mm alluminiam lugs , 2.5sq mm copper lugs , 2.5sq mm copper lugs pin typ , 6mm nut bolt , 10mm service cable 50mtr , 35x8 wood screw , 50x8 wood screw pkt , 35x8 pvc rawal plug , 10mm alluminiam lugs pungli , 16mm alluminiam lugs pungli , distil water 1ltr , 1sq mm polycab wire 90mtr bla , 1sq mm polycab wire 90mtr red , 100amp m c c b , contactor 11kv , 125amp m c c b , 2x2 earthing plate , earthing powder , 16a kit kat fuse , 2 core 1.5sq.mm drop wire(180mtr) , 2.5 sq.mm copper multistand cable , megger(meco make) , taparia plier , screw driver set , adjustable plier , elenki set , nose plier , submersible wire 6sq.mm 20 mtr , 3q contactor , nc contactor , 3 hp auto starter , single phase timer , 5 hp auto starter , 10 sq.mm service wire aluminium...

Rural Development Department - Maharashtra

37856867 supply of materials for led street lights in the financial year 2023 24 at gp. hinjawadi. supply of materials for led street lights in the financial year 2023 24 at g p. hinjawadi. , supplying and erectingled street light fitting suitable for 100 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , 26w led light to 100w led light repairing , 7 8 9 supplying & erecting frp box of size 250 x 200 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , old pole shifting, rework and foundation work per pole etc. , providingname and number for gp all street light using paint. , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 4core 16 sq mm , supplying and erecting steel tubular swaged pole 139.7x114.3x88.9mm. dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75m) length respectively and total 8 mlong with ppole cap, base plate in providing foundation.(weight 101 kg.) as per specification....

Municipal Copr Of Greater Mumbai - Maharashtra

37799024 tender for purchase of (1) alloy non precious – ceramometal (2) alloy ni cr (white metal ) (3) base plate (4) impression paste eugenol free (5) zinc oxide powder at nair hospital dental college....

Central Railway - Maharashtra

37793807 supply of plug in type relay interlockedplug in type relay interlocked,plug in type relay interlocked working on 60 v dc siemens make type rssk 30/0012 contact configuration 4f/4b (without base plate) conforming to irs s 46 with amendments and firms specification. [ warranty period: 30 months after the date of delivery ]...

Directorate Of Municipal Administration - Maharashtra

37745599 matheran electrical material supply , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning 11kv hrc fuse 10a to 40a for load break switch with necessary nut bolts complete. , supplying, installing, testing and commissioning 11 kv hrc fuse 63a for load break switch with necessary nut bolts complete. , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap ac/wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7tr to 0.9tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning ip epabx for 10 extensions complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 6 x 16 extension complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 3 x 8 extensions complete. , supplying, installing, testing & commissioning analogue type epabx of 3 x 8 extension complete. , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 2280 to 2850lpm at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 45kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 1600 to 1800 lpm at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 30kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning 3 phase, 22/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°c at ambient temp max 50°c & min 5°c at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage & frequency (+15% is tol) 1.80 kw, full load loss at rated current 3.00 kw, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 23 degree of protection, cable box arrangement at hv side & bus duct at lv side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & wti scanner with 3 pt 100 sensors, etc. standard accessories complete with test certificate (as per is:11171 & iec 60076 11) with necessary permissions of electrical inspector, as per specification no. ss tr. , supplying, installation, testing and commissioning 3 phase, 11/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oc at ambient temp max 50oc and min 50oc at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage and frequency (+15% is toi) 1 kw, full load loss at rated current 3.15 kw, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 21 degree of protection, cable box arrangement at hv side and bus duct at lv side, with rating and diagram plate, base channel, earthing terminals and wti scanner with 3 pt 100 sensors, etc., standard accessories complete with test certificates (as per is:11171 & is 2026) with necessary permissions of electrical inspector as per specification no. ss tr. , supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results specification no. ea mobi , supplying, fixing, and configuring modularised multi service router 802.11/a/n/ac unified wave 2.5 ghz, with rj 45 port, supporting 1 to 13 channels for 2.4 ghz, with unified wireless access point complete , supplying, fixing, and configuring 24 ports with 4 (sfp+) port, ethernet managed switch with web view/cli, 6kv surge protection on ethernet port and console port for management in provided rack as per specification no. wgnwc/gbs , supplying, fixing, and configuring 24 ports + 4 (sfp+) port, managed layer 2, poe switch of , 370w, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing, and configuring 20 sfp ports + 4 combo sfp 10/100/1000 base t erected in provided rack complete. , supplying, fixing, and configuring 20 (1g rj45) ports + 4 combo 1g ports + 4 10g (sfp+) ports, layer 3 switch, si image, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr / mcbcos , supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of ....... hrs. pwm & igbt based, with 0.8 to unity output pf complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 82.5 kva up to 100 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 62.5 kva up to 82.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 50 kva up to 62.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 40 kva up to 50 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 35 kva up to 40 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 25 kva up to 35 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 20 kva up to 25 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 15 kva up to 20 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 125 kva up to 140 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 100 kva up to 125 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 10 kva up to 15 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of diesel generating set with standard control panel with alternator of 5 kva continuous rating, single phase, 230v, 50c/s 0.8 p. f. ac supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self excited, selfregulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 1.3 ltr/hr @75% loading. engine and alternator directly coupled on a common fabricated steel base plate with anti vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. the complete set enclosed in acoustic enclosure made of 18 swg crca sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 db at 1.0 m. the engine with first filling of oil, diesel not less than 13 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 14.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 145 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 11.3 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 9.98 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 7.47 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.9 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 34.40 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db(a) at 1.0 m, provided with first filling of oil, diesel not less than 300 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.8 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 50 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 17.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 2.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of 6kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 3kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 28hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 20hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56°c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 12hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 6a to 32a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & commissioning mdf box 600x600 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 500x500 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 400x400 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 300x300 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 250x250 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 200x200 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 150x150 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 100x100 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 100a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying table fan of a.c. 230 v. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and hand shield type 3 pin plug top. , supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying led concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4w 6w led including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. , supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 star inverter type, stabilizer free operation suitable for operation on 100v/300 v, 50hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. , supplying and plugging 3 m fibre patch cord lc sc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc sc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and laying rigid steel conduit 16 swg 32 mm dia. with necessary accessories in rcc work/false ceiling/false flooring as per specification no: wgma/cc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and installing, testing & commissioning of digital (hybrid) type epabx of 6 x 32 extensions suitable upto 96 extensions complete. , supplying and fixing wireless n 150 desktop adapter in provided computer as per specification no. wg nas/lanc2 , supplying and erecting vpit heavy duty copper wound ballast 230v for 80 150w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting vpit compound heavy duty copper wound ballast for 230v for 250w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system. , supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) , supplying and erecting two pole power contactor 230 v, 32 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole metal clad changeover switch 240 v, 32 a erected on angle iron/gi frame and duly connected with suitable wire leads complete , supplying and erecting triple pole mini feeder pillar with 500v, 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a with aluminium bus bar erected in 14 swg crca sheet box with supporting angles, self locks, gasket having ip54,ik10 protection and slanting top to be erected on provided foundation complete as per specification no. sw , supplying and erecting t8 fluorescent tube day light 1200mm, 36 w , supplying and erecting t5 24 w energy efficient fluorescent tube. , supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt/bpc , supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.ap wh/stwh , supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kwh / 24 hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 2 ways (2 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 10 ways (10 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting shockproof t. switch 16 a porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof piano type switch 250 v, 16 a, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (trs type) pvc insulated copper wire of size 0.5 sq mm 5 m length connected to the point. , supplying and erecting shockproof 6a porcelain base t.switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected , supplying and erecting shockproof 3 pin plug socket 6a with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof 3 pin plug socket 16a with porcelain base/ flush type erected on filled polypropylene (is:14772 2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting rectangular shaped led panel light(1200mm x 300mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6a erected on m.s box made of 16 swg sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6 a combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor. , supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con , supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected , supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 1 module complete duly erected. , supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. , supplying and erecting pvc surface modular double mounting plate 8 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 6 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 4 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 3 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 2 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 16/18 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 12 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 1 module complete duly erected. , supplying and erecting pvc slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. , supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box . , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. , supplying and erecting porcelain base iron clad cut out hc type 415v, 63a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 32a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 200a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 16a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 100a erected on polished wooden block. , supplying and erecting pole clamp made from 50x6mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting pole clamp made from 50x10mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 63a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, , ip 54 and ik10 protection, 45 a tp contactor for automatic switching of luminaires, 2 no 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 32a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, ip 54 and ik10 protection, 25 a tp contactor for automatic switching of luminaires, 2 no. 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting one/two way piano type switch 6a./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting modular type two way switch 6a / 10a (2 module), duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch one way 16 / 20 a, duly erected on provided plate and box with wiring connections complete with neon indicator. , supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch 16a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type buzzer 220 / 250v, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type blanking plate two module, duly erected on provided plate & box , supplying and erecting modular type bell push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell push 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 6 / 16a fuse unit, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections , supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 600/650w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 1000w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (one module) electronic dimmer 400 / 450w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete , supplying and erecting metal halide lamp double ended 230v, 70 w . , supplying and erecting metal halide lamp double ended 230v, 250 w. , supplying and erecting metal halide lamp double ended 230v, 150 w . , supplying and erecting marine (waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to is 720:2010 , supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with 4x25 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 2x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230v a.c. supply with resetting arrangement complete erected on double wooden/ sunmica board. , supplying and erecting lszh armoured multimode optical fibre cable with 6 fibres, core dia 50/125 ?m (om4) suitable up to 10 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. wg coc/ofc , supplying and erecting led strip light 5m length max. 95 w ip20 class having minimum lumens output of 1600 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50 including driver with 1 year warranty. , supplying and erecting led strip light 5m length max. 45 w ip20 class having minimum lumens output of 800 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50, including driver with 1 year warranty. , supplying and erecting led square / circular max. 7w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led square / circular max. 25 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 18 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led panel light(600mm x 600mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg , supplying and erecting integrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf/fls2. , supplying and erecting integrated led street light fitting 120w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led post top 45w ip65 & ik10 class having die cast aluminium housing with uv protected polycarbonate diffuser, having system lumens output of min.4500 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 30,000 hrs. at l50b50 , including driver complete with 2 year warranty as per specification no fgodf/fls , supplying and erecting integrated led highbay fitting 135w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50,000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 70w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 8400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 5000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 30w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 3000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 195w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 23400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 155w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 18600 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 120w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min.14500 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 800mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 500mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting ignitor suitable for 230v hpsv lamp 70/150/250/400w as specification no. fg fg/as6 , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 70 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head / pin type 230v, 70 w son type. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma/con. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall /ceiling as per specification no: wg ma/con. , supplying and erecting gi wire of high purity of required sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete. , supplying and erecting gi strip of high purity required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint with joints required. as per specification no ea ep. , supplying and erecting gi sheet 0.8 mm (22 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gi sheet 0.6 mm (24 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12w led lamp on provided pipe as per specification no. fg , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, g.l. stay wire 7/8 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop insulator, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable ms clamps duly erected in provided c.c. foundations complete. , supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting g.i. pipe ‘c’ class erw 75/80 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15m long) with pole clamp, made of 50x6mm ms flat, erected on provided rsj pole complete. (add. rs. 25/ per m for extra length beyond 15 m) , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for, 1kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top suitable for with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 4kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting four pole power contactor 430 v, 16 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting flush, shock proof plug socket 6 pin 6a and 16a with switch 16a combined unit erected in recess in 16 gauge m.s sheet box duly painted and connected with earth terminal and leads , supplying and erecting flush type, shockproof plug socket 6 pin 6a and 16a with switch 16a combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with s m screws and duly connected. , supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. , supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. , supplying and erecting exhaust fan heavy duty 230 v, a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 1400 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg , supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn/cf , supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of 28w having service ratio (cmm/w) of min. 8 , pf>0.9, thd , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 76w100w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th , supplying and erecting electronic type driver for outdoor led fittings 46w75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<1 , supplying and erecting electronic type driver for outdoor led fittings 26w45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and , supplying and erecting electronic type driver for outdoor led fittings 151w200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 101w150w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd , supplying and erecting electronic ignitor suitable for 230v metal halide lamp 70/150/250/400w (integral or non integral type luminaires as specification no. fg fg/as6 , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. , supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. as per specification no. eaep. , supplying and erecting control gear for non integral flood light fittings suitable for 2x250w hpsv/mh lamp with all accessories complete. , supplying and erecting control gear for non integral flood light fittings suitable for 1x400w hpsv/mh lamp with all accessories complete. , supplying and erecting condenser for mv/sv/mh lamp 250w,230v as specification no. fg fg/as7 , supplying and erecting condenser for mv/sv/mh lamp 150w,230v as per specification no. fg fg/as7 , supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting c type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting c type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. , supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no ea ep. , supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles a.c. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting acrylic sheet 3 mm thick to be used for covering the crca sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete. , supplying and erecting 75 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 50 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 40 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 30 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 570 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries) , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries , supplying and erecting 12v/80ah to 88ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/7ah 7.5ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/42ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/26ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/17ah 18ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/130ah to 135ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. , supplying and erecting 12.5 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/hm (excluding luminaries , supplying and erecting 12 v/65ah smf battery with battery terminal wire, duly charged complete with 24 months warranty complete , supplying and erecting 11 kv outdoor type gang operated air break, triple pole switch 200 a capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of c class g.l. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground level with necessary clamp. , supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 100 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting ‘d’ type pole clamps, fabricated from 50x6mm ms flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12 exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12 exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(e), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating 11 kv(e), 3 x 70 sq. mm., aluminium conductor xlpe insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. cb ht , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300 x 200 x 150 mm complete on pole as per specification no. cb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 150 x 100 x 100 mm complete on pole as per specification no. cb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 , supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting three phase, 415v, street light control panel up to the max load of 12kw, tpn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 4 pole contactor up to 60a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 2 pole contactor up to 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting single pole cut point channel set of for 11kv ht oh line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. , supplying & erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ cc foundation. , supplying & erecting single phase, 240v, street light control panel up to the max load of 12kw, spn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting single compression type brass cable glands for 4 core 35 sq.mm./3 core 50 sq.mm. for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying & erecting ms pole bracket for lt oh conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 2.25 kw/3 hp with discharge 600/110 litres per minute (lpm) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 1.5 kw/2 hp with discharge 600/140 litres per minute (lpm) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 5.625 kw/7.5 hp with discharge of 780/170 litres per minute (lpm) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 3.75 kw/5 hp with discharge 715/200 litres per minute (lpm) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 230v, single phase 50 cycles a.c. supply of 1.125 kw/1.5hp with discharge 198/50 litres per minute (lpm)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (light house type) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (globe type) suitable for led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. fg , supplying & erecting inline d.p. structure for 11/0.415kv, 63kva transformer with rsj pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of crca sheet 16 swg with 4 pole mccb 100a as incomer & 6 nos. 63a kitkat/mccb for outing circuits. transformer d.p. structure includes the a.b. switch 200a, d.o. fuse set & l.a. set. 2 nos. top channel of size 100x50mm for erection of a.b. switch & 2 nos. base channel of size 100x50mm for erecting transformer channel of size 75x40mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 200 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 300 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete , supplying & erecting g.i. pipe ‘a’ class 75 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting fully automatic star/delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. , supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting four pole on load change over switch, 415v, 63a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 40a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 32a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3 . , supplying & erecting four pole on load change over switch, 415v, 315 320a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 200a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 160a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 100a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 10 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 h.p. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 h.p. , supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 h.p. , supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification no. cb cl/al , supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 30 a, 3 pin plug & earth socket and 30a, 3 pin plug top with 30a triple pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron / gi frame. , supplying & erecting co axial copper cable low voltage grade tri shielded rg11 as per specification no. wg tw , supplying & erecting co axial copper cable low voltage grade tri shielded rg , supplying & erecting cast iron cable indicator plate buried along with route of cable for pvc / xlpe armoured cable as per specification no. cb cip , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 hp consisting of star delta starter having relay range 9 14 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 15 hp consisting of star delta starter having relay range 13 22 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e , supplying & erecting 14w, 230v integral type led lamp suitable for b 22 / e27 base. , supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. , supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 0.5 mm dia, copper jumper wire as per specification no. wg tw , supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. , supply and erecting 9m (clear height) fixed type high mast (top 100mm, bottom 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. oh pl/opl (excluding luminaires). , rewinding the motor of the exhaust fan 900 / 1400 rpm 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year , rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. , rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for original speed and consumption with guarantee for 1 year including transportation from site and back , rewinding of electric motor upto 1 h.p. single phase up to 1400 rpm of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year. , rewinding of electric motor up to 1 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 7.5 h.p. upto 10 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea , rewinding of electric motor above 5 h.p. upto 7.5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 3 h.p.upto 5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 2 h.p. upto 3 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 1 hp upto 2 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. , providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep , providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 kilogram). , providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as per specification no. cb jt/ht , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 400 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 300 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 200 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 150 mm width & 100 mm height comprising all required standard accessories , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 8 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no sw swr/mccbpb. (excluding mccbs) , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 12 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no. sw swr/mccbpb. (excluding mccbs) , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as per specification no. cb jt/lt , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure/panel as per specification no. sw swr/mccb , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. oh pl/opl , point wiring in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/fan/bell in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire with flush type switch and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/cw , point wiring for independent plug, concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/c , point wiring for ceiling fan (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw/hw , making trench in soft soil having 0.9m depth and minimum 0.3 m width as per is for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. external surface duly plastered by 12 mm thick including watering etc complete , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). , excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. , concealing of provided g.i. pipe/h.g. screwed conduit/pvc pipe in wall/floor/false ceiling complete as per specification no:wg pw/cw , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole)....

Rural Development Department - Maharashtra

37745362 supplying electrical materials and repair maintenance services at. grampanchayat gahunje tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in etc...

Central Railway - Maharashtra

37735738 supply of base plate for smgr to m / s.bt pt.no.a 1101or m / s.aal pt.no.m 1101 as per rdso drg. no.skel 4658. [ warranty period: 30 months after the date of delivery ] ...

Municipal Corporation - Maharashtra

37728632 tender for supplying and erecting ms decorative combo pole 6 meter long. bottom section: 1.5 meter long, made as under cl base 250 mm long, ms grooved pipe 140 mm od, 900 mm long ,aluminium die casting decorative neck 350 mm long . middle section: made out of 90 mm od grooved pipe 3 meter long with aluminium ring 2 no.this rings apart 1.5 mtr distance from each other, with aluminium decorative neck 2 no. 180 mm long. top section: made out od 76.1 mm od pipe 1.5 meter long with aluminium decorative top dome built in junction box with mcb and connector, mounting base plate 250x250 x12 mm pole should be painted with pu paint antic finish complete...

Directorate Of Municipal Administration - Maharashtra

37708045 yearly electric material supply , incandescent bulb 60 w , 36 watt t4 4 feet , 24 watt t5 , hpsv lamp 150 w , hpsvlamp 250 w , led square / circular 16 to 20w downlighter , 5w 8 wled bulb , 10w 12w led bulb , 14 w led bulb , 18 w led bulb , t4 choke copper , t4 choke electronic , t5 choke copper , t5 choke electronic , t4 starter , t4 side holder , t5 side holder , metal halide lamp 250 w double ended , metal halide lamp 400 w double ended , condenser for 150 w mv / sv / mh lamp , condenser for 250 w mv / sv / mh lamp , condenser for 400 w mv /sv /mh lamp , ignitor for 70/150/250/400 w hpsv lamp , electronic ignitor for 70/150/250/400 w metal halide lamp , copper choke for80w 150 w hpsv/mv/mh lamp , copper choke for250 w hpsv/mv/mh lamp , copper choke for 400 w hpsv/mv/mh lamp , , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size , supplying and erecting modular type telephone socket one gangwith safety shutter isi mark approved make duly erected on provided plate and box with wiring connections complete. , fan condenser 2.5 mf , fan clamp , fan hook , electronic fan regulator for 600/900/1200/1400 mm sweep fan , cabinfan 300 mm(complete) , ceiling fan 900 mm with regulator (complete) , ceiling fan 1200 mm with regulator (complete) , desert air cooler 12 exhaust fan with 50 ltr capacity tank , desert air cooler 15 exhaust fan with 68 ltr capacity tank , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps & with dual function cartritge with output of purified water 2 ltr/min with activated carbon filter and softener operating on 230 v single phase a.c. supply. , rewinding of cabin fan 300( with 1 year guarantee) , rewinding of ceiling fan 900( with 1 year guarantee) , rewinding of ceiling fan 1200( with 1 year guarantee) , 12 exhaust fan rewinding of desert air cooler ( with 1 year guarantee) , 15 exhaust fan rewinding of desert air cooler ( with 1 year guarantee) , 20 mm pvc conduit with necessary accessories like saddle, screws. , 25 mm pvc conduit with necessary accessories like saddle, screws. , pvc trunking (pvc casing ncapping) of size 20 mm with accessories , pvc trunking (pvc casing ncapping) of size 25 mm with accessories , point wiring for light/fan/bell in 20 mm rigid pvc conduit with 1.5 sq.mm (2+1e) fr grade copper wire,flush type switch, earthing and required accessories as per specification no: wg pw/sw , pvc junction box 2 way/3 way/4 way , ceiling rose / batten holder / slanting holder /hanging cord switch / hanging bell push /pendent holder bakelite base 6a , 1 way 5 ampere switch/2 way 5 ampere switch , 3 pin 5 ampere socket , , 16 ampere (240 v)switch , 16 ampere (240 v)socket , wooden board 12 * , supplying & erecting on line ups pure sine wave of 5 kvacapacity complete with standard features, along with necessary smf batteries for 30 mins battery backup, as per specification no. ap ups(including labour charges) , supplying and erecting 12 v/135ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete(including labour charge) , supplying, installing, testing & commissioning of 2500 va digital pure sine wave inverter based on igbt technology single phase 230v,50 hz complete as per specification no. ap inv (without batteries)(including labour charges) 1 sqmm. flexible wire , 1.5 sqmm. flexible wire , 2 sqmm. flexible wire , 2 pole 250 v 12 amp contactor , 2 pole 250 v 32 amp contactor , 4 pole 440 v 16 amp contactor , 4 pole 440 v 40 amp contactor , double pole isolator 40 amp , triple pole isolator 40 amp , triple pole isolator 63 amp , four pole isolator 40 amp , four pole isolator 63 amp , pole above 6 mtr dismantling , mcb 6 to 32 amp(lightning) , mcb 40to 63 amp(lightning) , mcb 6 to 32 amp(motor/power) , mcb 40 to 63 amp(motor/power) , jcb / breaker excavation for onsite cable trench work , supplying and erectingrolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with provided base plate in provided foundation as per specification no. oh pl/rsj , supplying and erecting fibre/ pvc spacers for l.t. overhead line 3 to 5 conductors complete erected , supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.l. strips, nuts and bolts, complete. , supplying and erectingaluminium bobbin with g.l. strip, nuts complete , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7/10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7/10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7/10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , ??.??. ?????? ????? , ???? ????? ? ??. x ? ??. , ???? ????? ?? ???? ????? ??????? ? ??. x ? ??. , making trench in soft soilof suitable width and depth as per is for laying provided l.t cable up to 25 sq mm complete. as per specification no. cw exn ctr( inclusing labour charges) , making the trench in hard murum/tar roadof suitable width and depth as per is for laying provided l.t cable up to 10 sq.mm.complete. as per specification no. cw exn ctr , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep(including labour charges) , 20 ft staircase set , combination plier , screw driver , tester , ring pana sett / hand tools kit , patti pana set / hand tools kit , tong tester , megger meter , extention box(including 4 plug) , hydrolic aluminium body 40 ft staircase set (panel type) , lugdje fixing machine , drill machine , small capacity blower , small capacity cutter , 15 mm copper pipe , 10 mm copper pipe , 5 mm copper pipe , hand gloves , labour charges for repairing central pole light , labour charges for repairing central pole light , suplying g.i. bracket ( 3/4 to 3/2)inch , supplying cement pole clamp with nut bolt , supplying rsj pole clamp with nut bolt , labour charges for repairing high pole...

Rural Development Department - Maharashtra

37705211 tender for providing, erecting and supplying various different electric material for 1 year@grampanchayat lonikalbhor , electric material this rate please mentioned include gst invoice shall be prepared with gst tax whatever applicable on material rate are mentione with gst , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. , supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt , making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total6 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 147 kg ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness ( 5 + 2.5 + 2.5 m ) length respectively and total 10 m long with pole cap, base plate in provided foundation ( weight 160 kg ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness ( 5.60 + 2.7 + 2.7 m ) length total 11 m long with pole cap, base plate in provided foundation ( weight 175 kg. ) as per specification no. . oh pl / stp , supplying and erecting street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt / bpc , supplying, tpmcb 40a to 63a in provided distribution board , supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution boardas per specification no. swswr / mcb , supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink bajaj , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification nobajaj. fgodf / fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls2 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sinkbajaj , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf / fls 2 , 2 5 17 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf / fls 2 , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specificationjno. fg bkt / bpc ( 2 9 2 ) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb ( 2 9 3 ) , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 2core 6 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying & layingpvc armoured cable 4core 25 sq mm , supplying, erecting & terminating xlpe armoured cable 3½ core70sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core95sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous , supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) , supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole , supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no:gma / bw , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l / t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker ( 1 hours ) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 13 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specificationbajaj no.oh pl / opl. , providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70 mm a / f on provided foundation as per specification bajajno. oh pl / opl , providing & erecting 10 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 175 mm a / f, top 70 mm a / f on provided foundation as per specification bajaj no. oh pl / opl , providing & erecting 11 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 210 mm a / f, top 90 mm a / f on provided foundation as per specificationbajaj no. oh pl / opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl / hm ( excluding luminaries ) . , making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no. sw swr / mfp , supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , supplying and erecting regular / standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. fg fn / cf , supplying and erecting regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position as per specification no. fg fn / cf , supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 150 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 100 w bulb , 200 w bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18 / 20 tube light , lamp holder china clay , lamp holder ( pendent ) , rsj pole 9 mtr , v cross arm 22 kv , cut pont set 22 kv , pin insulater22 kv , disc insulater 22 kv , nut bolt , conductor 55 sq mm aac , ht stay set , lt stay set , stay wire , gi wire 8 swg , pole errection , conductor errection , v crosfixing , cutpoint fixing , mcb box metal 4 way , supply of tiranga pole as per sepcifucation 139.7mm od pipe 3mtr 114.3mm od pipe 1mtr 03 nos 88.9mm od pipe 2 mtr total 8 mtr pole , gst charges...

Rashtriya Chemicals And Fertilizers Limited - Maharashtra

37681226 tender for custom bid for services 2324 1012 grand total price including gst for repairing of shell replacement of gear box foundation base plates internals lifter spiral lump catcher of spherodizers in suphala plant at rcf trombay unit as per sow ( 1 )...

Western Railway - Maharashtra

37675163 auction sale of 98050114 scrap released p way rail fittings such as released slide chairs, joggle fish plates, fish plates, junction fish plates, bearing plates, special bearing plates, ms acb plates, mscb plates, base plates, gauge tie plates, strecher bars, gluid joints with without nut, bolts. tie bars and fiber attachments fiber attachments, etc. of sorts and sizes, rusty, broken and damaged, unserviceable for rly. use, loading by purchaser, [custodian dms mm]....

Ministry Of Railways - Maharashtra

37657612 bids are invited for stopper for sliding glass shutter with base plate for bus type window. material: aluminium powder coated, as per is: 737 63400 wp, as per item no 12 of drg. no: c&w.lgd.sk.no.1070...

Rural Development Department - Maharashtra

37657277 etender / 03 / 2023 24 / solar / 2 solar , providing and erecting solar street lights pole at grampanchayat dari, taluka nashik district nashik , each supplying and erecting g.i. pipe pole b class 80 mm dia 6 mlong with pole cap, base plate in provided foundation as per specification no. oh pl / gip , each supplying, installing, testing and commissioning c 10 batterywith capacity of 12v, 40 ah with duty cycle 10 12 hrs. suitable t charge on p v cell with necessary wiringconnections, nut bolts on provided stand with five years warranty as per specification no. esd sol / bat , each supplying and erecting integrated led street light fiting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min 2300 lumens, min. efficacy of 100 lumen / w, cri>70, cct , supplying, installing, testing and commissioning of solar panelcomprising high efficiency poly crystalline / multi crystalline photovoltaic cell 100wp, 12v with necessary clamps and module frame on existing structure complete. specification no.esd sol / cell , making making cement concrete foundation including excavation ( 60*60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm 145 cm dia. x45 cm height stone plinth metal, duly ( 45 plastered, x 45 x with 45 ) cm necessary curing and finishing complete. ( above 6 m to 9 m poles ) , shooting of till photographs construction and other works jo building bridges, roads, etc.in district and outside dist. at any distances. i still photos...

Kalyan Dombivli Municipal Corporation - Maharashtra

37650934 tender for providing supplying and erecting coupled pumpset nr. pingara hotel in ward.supplying & erecting minimum three & above star rated 3 phase, 415 v, 50 hz, bronze impeller coupled with 18.75 kw/25 hp 4p ole ie2 tefc motor mounted on common base plate with coupling guard and bolt with discharge 360 202 m3/hr for head of 9 19 m, duty point head 245 m3/hr (@ 12 m head and 150mm suction/ 125 mm delivery pipe of size, on provided c.c. supplying & erecting minimum three & above star rated 3 phase, 415 v, 50 hz, bronze impeller coupled with 22.50 kw/30 hp 4 pole ie2 tefc motor mounted on common base plate with coupling guard and bolt with discharge 360 202 m3/hr for head of 9 19 m, duty point head 290 m3/hr @ 12 m head and 150mm suction/ 125 mm delivery pipe of size, on provided c.c. 1.00 foundation. foundation....

Rural Development Department - Maharashtra

37596244 supplying erecting transformer to neral water supply scheme ( 175 hp) neral tal karjat raigad , supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m)with base plate in provided foundation as per specification no. oh pl/rsjt dsr ino. 8 1 13 , supplying & erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thickflange channel iron cross arm of suitable length for 2.4 m wide dp structure and erecting on dp with 50x6mm clamp complete as per specification no. oh pl/bktdsrno.8 3 11 , supplying & erecting 75 x 40 x 6 mm with 4.7 mm thick web and 7.5 mm thickflange channel iron cross arm of suitable length for 2.4 m wide dp structure and erecting on dp with 50x6mm clamp complete as per specification no. oh pl/bktdsrno.8 3 8 , supplying & erecting 75 x 40 x 6 mm with 4.7 mm thick web and 7.5 mm thickflange channel iron cross arm of suitable length for 2.4 m wide dp structure and erecting on dp with 50x6mm clamp complete as per specification no. oh pl/bktdsrno.8 3 9 , supplying and erecting pipe type earthingwith gi pipe complete with all materials, testing & recording the results asper spe no. ea epdsr ino.9 1 4 , supplying and erecting porcelain pin type insulator with gi pin suitable for 22 kv line, complete as per specification no. oh ins/pndsr ino. 8 5 10 , supplying and erecting porcelain disc type insulator 45kn with necessaryhardware suitable for 11kv line, complete as per specification no. oh ins/didsr ino. 8 5 6 , supplying , erecting & terminating xlpe insulated, galvanised steel formedwire armoured (strip) cable 11 kv(ue), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb htdsr ino. 7 3 7 , supplying, installing, testing & commissioning 3 phase, 22/0.433 kv, 50 hz., 315kva, mineral oil immersed and naturally cooled outdoor type, copper wound, without gas cushioning , hermetically sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50? by the resistancemethod in winding at full load rating, using type a winding insulation (kraft paper) with hv tapping (with off load tap changer) off load +5 to 10 in steps of2.5%, having 7 number of tap positions with standard accessories complete withtest certificate with losses below 1076 watts at 50% load, 3255 watts at 100%load as per is:1180 (part 1) 2014 with necessary permissions of lectricalinspector, as per specification no ss tr sltdsr ino. 7 3 8 , supplying , erectingdtc metering with box & other allined material for 315 kva transformeras per specification no. cb ht , supplying , erectingdtc metering cubical 10/5 ampfor 315 kva transformeras per specification no. cb ht , supplying and erecting fencing of section having size 2450 mm in height fromground level and 1200 mm width with angle iron frame work erected in cc foundation and painted complete as per specification no ss as/fsg dsr ino 10 7 18 t , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavationin ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portionshall be filled with 40mm hard broken aggregate. external surface dulylasteredby 12 mm thick including watering etc complete. dsr ino 16 3 1 t , supplying and erecting all aluminium stranded conductors 7/3.10 mm.complete. (ant.) (145.0 kg/km) as per specification no. oh con/aacc dsr ino 8 4 5 , providing cement concrete foundation includingexcavation for the poles 60 cms. x 60 cms. x 1.5 mtr. deep in 1:3:6 cement concrete(20 x 25 mm. stone metal) and 45 cm x 45 cm x 45 cm/45 cm.dia. x 45 cm.heightplinthduly plasteredand withnecessary curing and finishing in an approved manner. (for 8.5to 9 mtr poles). dsr ino.16.3.2 , supplying and erecting, 22 kv outdoor type drop out fuse with insulatorcomplete with fuse holders, fuse barrel with metal fitting, fuse elementmounted on m.s. channel with working current of 15a capacity completeerected on provided cross arm.).dsr ino.10 6 6 , supplying and erecting isi mark gi pipe 100 mm dia ‘c” class position withaccessories complete. spec no. cw plb/gp..dsr ino.16 5 15 , 1.3 % mseb supervision charges , add 18 % gst tax , 1 % w0rk insurance...

Rural Development Department - Maharashtra

37581230 providing supplying erectiong various material for 1 year at grampanchayat(gp fund) providing supplying erectiong various electric material for development for 1 year at grampanchayat kadamwakwasti haweli(gp fund) , electric material this rate please mentioned include gst invoice shall be prepared with gst tax whatever applicable on material rate are mentione with gst , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total6 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5 + 2.5 + 2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation (weight 175 kg.) as per specification no. . oh pl/stp , supplying and erecting street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt/bpc , supplying,tpmcb 40a to 63a in provided distribution board , supplying, erecting & marking dpmcb 40a to 63a, b series (for lighting) in provided distribution boardas per specification no. swswr/mcb , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink bajaj , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification nobajaj. fgodf/fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls2 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sinkbajaj , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf/fls 2 , 2 5 17 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf/fls 2 , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specificationjno. fg bkt/bpc(2 9 2) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt/wb(2 9 3) , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 2core 6 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying & layingpvc armoured cable 4core 25 sq mm , supplying, erecting & terminating xlpe armoured cable 3½ core70sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core95sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole , supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no:gma/bw , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75/80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75/80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 13 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specificationbajaj no.oh pl/opl. , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification bajajno. oh pl/opl , providing & erecting 10 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 175 mm a/f, top 70 mm a/f on provided foundation as per specification bajaj no. oh pl/opl , providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm a/f, top 90 mm a/f on provided foundation as per specificationbajaj no. oh pl/opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m (clear height) high mast (top 150mm, bottom 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl/hm (excluding luminaries ). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no. sw swr/mfp , supplying & erecting street light control panel in powder coated crca 14/16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto/manual selector switch,on/off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 150 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 100 w bulb , 200 w bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18/20 tube light , lamp holder china clay , lamp holder (pendent) , rsj pole 9 mtr , v cross arm 22 kv , cut pont set 22 kv , pin insulater22 kv , disc insulater 22 kv , nut bolt , conductor 55 sq mm aac , ht stay set , lt stay set , stay wire , gi wire 8 swg , pole errection , conductor errection , v crosfixing , cutpoint fixing , mcb box metal 4 way , gst charges...

Ministry Of Defence - Maharashtra

37554325 bids are invited for 50 mm colostomy kit base plate ( 5 ) triple hydrocolloid skin barrier where no cutting ( moldable ) is required comprised of pectin, gelatin and sodium carboxy methyl cellulose, elastomeric polymers extending turtle necking effect and rebounding memory technology with audible click and flexible tape collar consist of 14 items colostomy bag s ) it should be drainable pouch 12, with filter embedded & 2 sided hydrophobic comfort panel standard, opaque with integrated dotted velcro tail closure. stomahesive powder ( 1 ) hydrocolloid based skin protection powder ostomy belt g ) unisex adjustable waist support belt with stretched fabric with hook and loop stomahesive paste { 2 ) alcohol base hydrocolloid skin protection paste for creating a tight seal , fill deeper cavities and folds...

Department Of Fertilizers - Maharashtra

37467986 custom bid for services 2324 1012 grand total price including gst for repairing of shell replacement of gear box foundation base plates internals lifter spiral lump catcher of spherodizers in suphala plant at rcf trombay unit as per sow contract period / अनुबंध अविध...

Western Railway - Maharashtra

37411543 supply of switch plate assembly for lhb gs coaches specification edml 127 rev 1, drg.nocc74249 alt a, and drg.no cc74248 alt a at both cabin side and corridor side in equal quantity accepted make : ssk / sks / records / cpl [ warranty period: 30 months after the date of delivery ] , switch plate assembly complete with polycarbonate cover frame and powder coated steel base plate with 4 nos. on off switches and 1 no. 5 pin socket 6a, 250v, ac with 1 no. 0.5 amp glass fuse of m / s. ferraz / shawmut / cooper bussman with fuse holder with inscription as l, f, nl, cs, 110v, as per icf specification no. icf / edml 012, rev a, with correction slip no. 3 and drawing no. icf / sk3 7 4 013, alt. b, item no. 1. accepted make : ssk / sks / records / cpl [ warranty period: 30 months after the date of delivery ] ...

Rural Development Department - Maharashtra

37403092 providing and erecting solar street lights pole at grampanchayat dari, taluka nashik district nashik , providing and erecting solar street lights pole at grampanchayat dari, taluka nashik district nashik , each supplying and erecting g.i. pipe pole b class 80 mm dia 6 mlong with pole cap, base plate in provided foundation as per specification no. oh pl/gip , each supplying, installing, testing and commissioning c 10 batterywith capacity of 12v, 40 ah with duty cycle 10 12 hrs. suitable t charge on p v cell with necessary wiringconnections, nut bolts on provided stand with five years warranty as per specification no. esd sol/bat , each supplying and erecting integrated led street light fiting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct , supplying, installing, testing and commissioning of solar panelcomprising high efficiency poly crystalline/ multi crystalline photovoltaic cell 100wp, 12v with necessary clamps and module frame on existing structure complete. specification no.esd sol/cell , making making cement concrete foundation including excavation (60*60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm 145 cm dia. x45 cm height stone plinth metal, duly (45 plastered, x 45 x with 45) cm necessary curing and finishing complete. (above 6 m to 9 m poles) , shooting of till photographs construction and other works jo building bridges, roads, etc.in district and outside dist. at any distances. i still photos...

Rural Development Department - Maharashtra

37384290 jet pump monoblock pump bare pump underwater pump vtpump india mark 2 and mark 3 hand pump repairing and spare parts rate for zilha parishad bhandara , jet pump,monoblock pump, bare pump underwater pum all submit rate as pergsda item sheet , india mark 2 & 3 hand pump repairing drive out thepipe line with diameter of 65.0 m.m. , drive outthepipe line with diameter of 65.0 m.m which fell in well. , drive out thepipe line with diameter of 32.0 m.m from whichfell in well. , drive out thepipe line with diameter of 32.0 m.m from well. , repairing of jet motor pump & pipelinedrive out inner pipeline with jet assembly of jetpump from 1.0 hp to 5.0 hp well. , to fit the inner and outer pipeline of the jet pump in 1.0 hp to5.0 hp well. , to insert inner pipeline of jetpump in well. (after repairing.) , to insert inner & outer pipeline of jetpump in well. (after repairing.) , to pull out the stucked, fell or caught in dreg pump set.( contracter use their own tools.) , to increse or reduse the pipe line of jet pump inh well. ( for every 3.0 m. ) , to submit in the officejet pump, motor pipeline, starter panel board tin & other assesaries of laghu panee purwatha yojna in well. , new pump set (upto 1.0 to 5.0 hp) to fit in well, to give panel wiring arthig test report & start after electric supply. (z.p. providespumpset panel, arthing material g.i. wire, plate, pipe andother assesaries.) , to drive out motor and pump from jet pump , to fit1.0 hp to 5.0 hp jet motor pump. , to rewinding electric motor with copper wire , above rate valid forwithout returning old copper wire, 1.0 hp to 5.0 hp open pump motor rewinding. , to open the jet motor, over oiling, fitting and testing , roter pump shaft turning and polishing. , to make upper and lower bush of baring cover sit and housing of jet pump. , to test electric pump on site ( transport and with minor repairing) , to repaire panel board & starter of all types motor & any hp control panel starter minor repairing to fit grif set, rottery swich, contracter plate, ampear meter, volt meter, on off switch, fuse and minor wiring. , starter panel board main repairing & to fit coilrelay, single phasing preventer water label guard & totle wiring of 1.0 hp to 10.0 hp pump. , starter panel board main repairing & to fit coilrelay, single phasing , preventer water label guard & totle wiring of 10.0 hp to 30 hp pump. , preventer water label guard & totle wiring of 31.0 hp to 40 hp pump. , to remove tin shed flashing of pump if necessary and fit as it is after work. , to remove handpump with pipeline for flashing and insert 10 feet g.i.pipeline towards 32 m.m. dimeter& remove after flashing and fithandpump as it is before. , to remove handpump for capacity test and after testing fit as it is before. , single phase 1 hp to 2 hp electric pump capacity test for regular three hour with help of generator , yieldtest 1 hp to 2 hp electric pump capacity test for regular three hour with help of generatorwith necc equip , yieldtest 2 hp to5 hp electric pump capacity test for regular three hour with help of generatorwith necc equip , yield test 2 hp to5 hp electric pump capacity test for regular three hour withouthelpof generatorwith necc equip , spare parts of jet pump baring upper , baring lower , empelor key , pump bush , air fan ( with pvc pin) , stand nut kit , nut bolt kit , air cock , pressure regulating volve , pressure regulating difrom , baring plate top / bottom , jet assembly packer type full , packer foot volve , packer rubber seal set , packer backet set , gland rope , rubber packing set , gland rope plate , empelor , d) other material g. i. coplling heavy duty , i) 32 m.m. , ii) 40 m.m. , iii) 50 m.m. , iv) 65 m.m. , v) 75 m.m. , vi) 100 m.m. , vii) 125 m.m. , viii) 150 m.m. , bend heavy duty , i) 32 m.m. , ii) 40 m.m. , iii) 50 m.m. , iv) 65 m.m. , v) 75 m.m. , vi) 100 m.m. , vii) 125 m.m. , viii) 150 m.m. , 3) foot volve:i) 32 m.m. , ii) 40 m.m. , iii) 50 m.m. , iv) 65 m.m. , v) 75 m.m. , vi) 100 m.m. , vii) 125 m.m. , viii) 150 m.m. , wooden board 3 x 2 f x ½ “ , iron box 18 guage tin 3f x 2f x 1f , g.i.pipe 1½“ / 1¼ “ cutting threding , g.i.pipe 2“ cutting threding , g.i.pipe 2½“ / 3 “ cutting threding , e)submercible pump repairing: 1.0 hp to 3.5 hp , 4.0 hp to 5.0 hp , 6.0 hp to 10.0 hp , 11.0 hp to 15.0 hp , 16.0 hp to 20.0 hp , 21.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , f) to remove motor pump set with pipelinefrom well: 1 hp to 6.0 hp , 7.0 hp to 15 hp , 16.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , g) to pull out the stuck, fell or caught in dreg pump set with pipelinefrom well: 1 hp to 6.0 hp , 2) 7.0 hp to 15 hp , 3)16.0 hp to 30.0 hp , 4)31.0 hp to 50.0 hp , h) to fit motor pump in well with pipe line: 1)1 hp to 6.0 hp , 2)7.0 hp to 15 hp , 3) 16.0 hp to 30.0 hp , 4) 31.0 hp to 50.0 hp , i) to increase or reduse pipeline of submercible pump in well rate 3 meter / per pipe: 1 hp to 6.0 hp , 7.0 hp to 15 hp , 16.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , j) to submit in the officejet pump, : 1 hp to 7.5 hp , 8.5 hp to 15 hp , 16.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , k) new pump set (upto 1.0 to 5.0 hp) :1 hp to 7.5 hp , 8.5 hp to 15 hp , 16.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , l) to open sub motor, repairing, fitting and testing.: 1 hp to 7.5 hp , 8.5 hp to 15 hp , 16.0 hp to 30.0 hp , 31.0 hp to 50.0 hp , m) to open sub pump, repairing, fitting and testing.:1)1 hp to 7.5 hp , 2) 8.5 hp to 15 hp , 3)16.0 hp to 30.0 hp , 4)31.0 hp to 50.0 hp , n) to repaire sub motor and sub pump:to sub motor / pump bush fitting per , damage stater repairing , roter shaft turning and polishing , damage roter repairing (rewinding) , sub pump shaft turning & polishing , to joint cable with kit , o) sub motor & sub pump spare parts1 to 5 hp: i) sub motor bush , ii) sub pump bush , thirst baring block , thirst baring full , block , ring , upper stage casing , lower stage casing , middle stage casing , i) empelor , ii) brass empelor , nekring , defuser , pump key , rubber parts kit , submotor base , stenner , male female bush , male famale key , nrv stage casing , stud big , stud small , motor bush housing , i) upper , ii) lower , alen srew , ss slivemotor /pump , ss slive cover , o) sub motor & sub pump spare parts1 to 7.5 hp: i) sub motor bush , ii) sub pump bush , thirst baring block , thirst baring full , block , ring , upper stage casing , lower stage casing , middle stage casing , i) empelor , ii) brass empelor , nekring , defuser , pump key , rubber parts kit , submotor base , stenner , male female bush , male famale key , nrv stage casing , stud big , stud small , motor bush housing , i) upper , ii) lower , alen srew , ss slivemotor /pump , ss slive cover , o) sub motor & sub pump spare parts 8 to15 hp :i) sub motor bush , ii) sub pump bush , thirst baring block , thirst baring full , block , ring , upper stage casing , lower stage casing , middle stage casing , i) empelor , ii) brass empelor , nekring , defuser , pump key , rubber parts kit , submotor base , stenner , male female bush , male famale key , nrv stage casing , stud big , stud small , motor bush housing , i) upper , ii) lower , alen srew , ss slivemotor /pump , ss slive cover , o) sub motor & sub pump spare parts16 to30 hp: i) sub motor bush , ii) sub pump bush , thirst baring block , thirst baring full , block , ring , upper stage casing , lower stage casing , middle stage casing , i) empelor , ii) brass empelor , nekring , defuser , pump key , rubber parts kit , submotor base , stenner , male female bush , male famale key , nrv stage casing , stud big , stud small , motor bush housing , i) upper , ii) lower , alen srew , ss slivemotor /pump , ss slive cover , 1)three ply coreflat flexible submercible cable: i) 1.5 sq.m.m. , ii) 2.5 sq.m.m. , iii) 4 sq.m.m. , iv) 6 sq.m.m. , v) 10 sq.m.m. , vi) 1.5 sq.m.m. , 1)three ply coreflat : arm cable:i) 1.00 sq.m.m. , ii) 1.50 sq.m.m. , iii) 2.50 sq.m.m. , iv) 4.00 sq.m.m. , v) 6.00 sq.m.m. , vi) 10.00 sq.m.m. , vii) 16.00 sq.m.m. , viii) 25.00 sq.m.m. , ix) 35.00 sq.m.m. , x) 50.00 sq.m.m. , copper wire p.v.c. insulated & p.v.c. coated: i) 3/20 , copper wire p.v.c. insulated & p.v.c. coated: ii) 7/20 , copper wire p.v.c. insulated & p.v.c. coated: iii) 7/16 , 27)new pump shaft i) 1.5 hp to 6 hp , 27)new pump shaft ii) 7.5 hp to 15 hp , 27)new pump shaft iii) 16 hp to 30 hp , borewell protecting plate , borewell protecting cover , p)25.0 hp to 40 hp v.t. motor pump set repairing 25hp: drive out v.t. motor from well , v.t. pump fit in well , drive out colume assembly with pipeline from well , to fit colume assembly with pipeline in well , to open v.t. motor , v.t. motor fitting & testing , bowl assembly fitting & testing , to open bowl assembly , v.t. pump rewinding with copper wire. withoutreturning old copper wire , allignment checking & repairing , i) line shaft , ii) colume pipe , iii) oil tube , cutting & threading , i) line shaft (r.h./l.h) , ii) colume pipe (r.h./l.h) , iii) oil tube (r.h./l.h) , to fit new flage, threading coller, welding,nutboltin colume pipe , to making ,bearing sheet on lathe machine , bearing plate both side , p)25.0 hp to 40 hp v.t. motor pump set repairing 35hp: drive out v.t. motor from well , v.t. pump fit in well , drive out colume assembly with pipeline from well , to fit colume assembly with pipeline in well , to open v.t. motor , v.t. motor fitting & testing , bowl assembly fitting & testing , to open bowl assembly , v.t. pump rewinding with copper wire. withoutreturning old copper wire , allignment checking & repairing , i) line shaft , ii) colume pipe , iii) oil tube , cutting & threading , i) line shaft (r.h./l.h) , ii) colume pipe (r.h./l.h) , iii) oil tube (r.h./l.h) , to fit new flage, threading coller, welding,nutboltin colume pipe , to making ,bearing sheet on lathe machine , bearing plate both side , p)25.0 hp to 40 hp v.t. motor pump set repairing 40hp : drive out v.t. motor from well , v.t. pump fit in well , drive out colume assembly with pipeline from well , to fit colume assembly with pipeline in well , to open v.t. motor , v.t. motor fitting & testing , bowl assembly fitting & testing , to open bowl assembly , v.t. pump rewinding with copper wire. withoutreturning old copper wire , allignment checking & repairing , i) line shaft , ii) colume pipe , iii) oil tube , cutting & threading , i) line shaft (r.h./l.h) , ii) colume pipe (r.h./l.h) , iii) oil tube (r.h./l.h) , to fit new flage, threading coller, welding,nutboltin colume pipe , to making ,bearing sheet on lathe machine , bearing plate both side , q)25 hp to 40 hp v.t. pum spare part 25hp : 1) v.t. motor baring , i) upper , ii) lower , discharge & sectioncase baring bush gun metal , water seal (oil water separater) , line shaft , oil tube , t.t. plate cast iron , brain rubber bush (spider) , net (cast iron) , nut bolt ¾“ x 2 “ , nut bolt ¾“ x 6 “ , rubber shit , t.t. plate bush , neck ring (gun metal) , impelor(gun metal) , browl assembly casing , 6” colume pipe m.s. , 8” colume pipe m.s. , transformer oil , pump colet , shaft tube oil 10 no. , impelor pump shaft , litern ring , gide spider , colume pipe coplling , line shaft coplling , oil tube baring , glad nut , top oil tube , spider baring bush , guide spider rubber bush with sirclip , rubber bush/ baring , line shaft slive s.s. , water lubricating tube , stuffing box bush & with gaskit , stuffing box baring , latern ring , sole plate , base plate , water deflector , q)25 hp to 40 hp v.t. pum spare part 25hp : 1) v.t. motor baring , i) upper , ii) lower , discharge & sectioncase baring bush gun metal , water seal (oil water separater) , line shaft , oil tube , t.t. plate cast iron , brain rubber bush (spider) , net (cast iron) , nut bolt ¾“ x 2 “ , nut bolt ¾“ x 6 “ , rubber shit , t.t. plate bush , neck ring (gun metal) , impelor(gun metal) , browl assembly casing , 6” colume pipe m.s. , 8” colume pipe m.s. , transformer oil , pump colet , shaft tube oil 10 no. , impelor pump shaft , litern ring , gide spider , colume pipe coplling , line shaft coplling , oil tube baring , glad nut , top oil tube , spider baring bush , guide spider rubber bush with sirclip , rubber bush/ baring , line shaft slive s.s. , water lubricating tube , stuffing box bush & with gaskit , stuffing box baring , latern ring , sole plate , base plate , water deflector , q)25 hp to 40 hp v.t. pum spare part 40hp: 1) v.t. motor baring , i) upper , ii) lower , discharge & sectioncase baring bush gun metal , water seal (oil water separater) , line shaft , oil tube , t.t. plate cast iron , brain rubber bush (spider) , net (cast iron) , nut bolt ¾“ x 2 “ , nut bolt ¾“ x 6 “ , rubber shit , t.t. plate bush , neck ring (gun metal) , impelor(gun metal) , browl assembly casing , 6” colume pipe m.s. , 8” colume pipe m.s. , transformer oil , pump colet , shaft tube oil 10 no. , impelor pump shaft , litern ring , gide spider , colume pipe coplling , line shaft coplling , oil tube baring , glad nut , top oil tube , spider baring bush , guide spider rubber bush with sirclip , rubber bush/ baring , line shaft slive s.s. , water lubricating tube , stuffing box bush & with gaskit , stuffing box baring , latern ring , sole plate , base plate , water deflector , i) drive out 1 hp to 3 hp monoblock pump , ii) drive out 4 hp to 10 hp monoblock pump , ii) 2 to 3hp monoblock motor rewinding , iii) 4 to 5hp monoblock motor rewinding , iv) 6 to 7½hp monoblock motor rewinding , v) 8 to 10hp monoblock motor rewinding , monoblock pump open, repairing, fitting & testing i) 1 to 1½hp , monoblock pump open, repairing, fitting & testing ii) 2 to 5hp , monoblock pump open, repairing, fitting & testingiii) 6 to 10hp , roter pump shaft turning & polishingi) 1 to 5 hp , roter pump shaft turning & polishingii) 6 to 10hp , to make monoblock pump bush & housing (baring)i) 1 to 1½hp , to make monoblock pump bush & housing (baring)ii) 2 to 5hp , to make monoblock pump bush & housing (baring)iii) 6 to 10hp , tofit new pump set i) 1 to 1½hp , tofit new pump setii) 2 to 5hp , tofit new pump set iii) 6 to 10hp , t) monoblock pump spare partsbaring1 to 1½ hp(driving side) , baring (driven side) , impelor key , pump bush , air fan , sturnut key , baring plate both side1 item , water seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , impelor brass , impelor c.i. , defuser , baring housing , neck ring , foot volve , fluge (dilevery/ suction) , shaft sleve , delivery casing , stater fitted motorbody , spacer , fan cover , water deflector , t) monoblock pump spare parts 2 to 3 hp baring (driving side) , baring (driven side) , impelor key , pump bush , air fan , sturnut key , baring plate both side1 item , water seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , impelor brass , impelor c.i. , defuser , baring housing , neck ring , foot volve , fluge (dilevery/ suction) , shaft sleve , delivery casing , stater fitted motorbody , spacer , fan cover , water deflector , t) monoblock pump spare parts 4 to 5 hp baring (driving side) , baring (driven side) , impelor key , pump bush , air fan , sturnut key , baring plate both side1 item , water seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , impelor brass , impelor c.i. , defuser , baring housing , neck ring , foot volve , fluge (dilevery/ suction) , shaft sleve , delivery casing , stater fitted motorbody , spacer , fan cover , water deflector , t) monoblock pump spare partsbaring 6 to 7½hp (driving side) , baring (driven side) , impelor key , pump bush , air fan , sturnut key , baring plate both side1 item , water seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , impelor brass , impelor c.i. , defuser , baring housing , neck ring , foot volve , fluge (dilevery/ suction) , shaft sleve , delivery casing , stater fitted motorbody , spacer , fan cover , water deflector , t) monoblock pump spare partsbaring 8 to 10hp(driving side) , baring (driven side) , impelor key , pump bush , air fan , sturnut key , baring plate both side1 item , water seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , impelor brass , impelor c.i. , defuser , baring housing , neck ring , foot volve , fluge (dilevery/ suction) , shaft sleve , delivery casing , stater fitted motorbody , spacer , fan cover , water deflector , u) bare pump repairingto drive out bare pump i) 10 to 20 hp , ii) 21 to 50 hp , bare pump to open, repairing, fitting & testing i) 10 to 20 hp , ii) 21 to 50 hp , pump shaft turning & polishing i) 10 to 20 hp , ii) 21 to 50 hp , to make pump bush & housing (baring) i) 10 to 20 hp , ii) 21 to 50 hp , to fit new bare pump i) 10 to 20 hp , ii) 21 to 50 hp , pump repairing & fittingi) 10 to 20 hp , ii) 21 to 50 hp , to make gland bush housing i) 10 to 20 hp , ii) 21 to 50 hp , drive out bare pump pipe line with foot volve i) 10 to 20 hp , ii) 21 to 50 hp , to fit bare pump pipeline with foot volve i) 10 to 20 hp , ii) 21 to 50 hp , v) bare pump spare parts 10 to 15 hp baring (ball baring) , rolar baring , impelor key , pump bush , stud nut , nut bolt kit , air cock , base plate , water seal , gland bush , gland plate , pump shaft , latern ring , impelor brass , impelor (c.i) , difuser , baring housing , neck ring (small) , neck ring (big) , flasher , foot volve , check nut , impelor housing , roter casing , roter , delevery casing , stuffing box bush , shaft sleve , water deflector , cuplling half flexible , baring cover , grees cup , flage section/ delivery , v) bare pump spare parts 16 to 20hp baring (ball baring) , rolar baring , impelor key , pump bush , stud nut , nut bolt kit , air cock , base plate , water seal , gland bush , gland plate , pump shaft , latern ring , impelor brass , impelor (c.i) , difuser , baring housing , neck ring (small) , neck ring (big) , flasher , foot volve , check nut , impelor housing , roter casing , roter , delevery casing , stuffing box bush , shaft sleve , water deflector , cuplling half flexible , baring cover , grees cup , flage section/ delivery , v) bare pump spare parts 21 to 50 hp baring (ball baring) , rolar baring , impelor key , pump bush , stud nut , nut bolt kit , air cock , base plate , water seal , gland bush , gland plate , pump shaft , latern ring , impelor brass , impelor (c.i) , difuser , baring housing , neck ring (small) , neck ring (big) , flasher , foot volve , check nut , impelor housing , roter casing , roter , delevery casing , stuffing box bush , shaft sleve , water deflector , cuplling half flexible , baring cover , grees cup , flage section/ delivery , w) bare motor repairingdrive out bare motor , w) bare motor repairingdrive out bare motor i) 10 to 20 hp , w) bare motor repairingdrive out bare motor ii) 21 to 50 hp , bare motor rewinding i) 1 to 5 hp , bare motor rewinding ii) 6 to 10 hp , bare motor rewinding iii) 11 to 15 hp , bare motor rewinding iv)16 to 20 hp , bare motor rewindingv) 21 to 30 hp , bare motor rewinding vi) 31 to 35 hp , bare motor rewinding vii) 36 to 40 hp , bare motor rewinding viii) 41 to 50 hp. , motor opening, over oiling, fitting & testingi) 1 to 5 hp , motor opening, over oiling, fitting & testingii) 6 to 10 hp , motor opening, over oiling, fitting & testing iii) 11 to 15 hp , motor opening, over oiling, fitting & testingiv)16 to 20 hp , motor opening, over oiling, fitting & testing v) 21 to 30 hp , motor opening, over oiling, fitting & testing vi) 31 to 35 hp , motor opening, over oiling, fitting & testingvii) 36 to 40 hp , motor opening, over oiling, fitting & testing viii) 41 to 50 hp. , roter shaft turning & polishing i) 1 to 5 hp , roter shaft turning & polishing ii) 6 to 10 hp , roter shaft turning & polishing iii) 11 to 15 hp , roter shaft turning & polishingiv)16 to 20 hp , roter shaft turning & polishing v) 21 to 30 hp , roter shaft turning & polishing vi) 31 to 35 hp , roter shaft turning & polishingvii) 36 to 40 hp , roter shaft turning & polishing viii) 41 to 50 hp. , to make motor bush & housing (baring sheet) i) 1 to 5 hp , to make motor bush & housing (baring sheet)ii) 6 to 10 hp , to make motor bush & housing (baring sheet)iii) 11 to 15 hp , to make motor bush & housing (baring sheet)iv)16 to 20 hp , to make motor bush & housing (baring sheet)v) 21 to 30 hp , to make motor bush & housing (baring sheet)vi) 31 to 35 hp , to make motor bush & housing (baring sheet) vii) 36 to 40 hp , to make motor bush & housing (baring sheet) viii) 41 to 50 hp. , to fit new motor i) 1 to 5 hp , to fit new motor ii) 6 to 10 hp , to fit new motoriii) 11 to 15 hp , to fit new motoriv)16 to 20 hp , to fit new motorv) 21 to 30 hp , to fit new motorvi) 31 to 35 hp , to fit new motorvii) 36 to 40 hp , to fit new motor viii) 41 to 50 hp. , panel board & starter repairingi) 1 to 5 hp , panel board & starter repairingii) 6 to 10 hp , panel board & starter repairingiii) 11 to 15 hp , panel board & starter repairingiv)16 to 20 hp , panel board & starter repairing v) 21 to 30 hp , panel board & starter repairing vi) 31 to 35 hp , panel board & starter repairing vii) 36 to 40 hp , panel board & starter repairing viii) 41 to 50 hp. , to fit motor as it isi) 1 to 5 hp , to fit motor as it isii) 6 to 10 hp , to fit motor as it is iii) 11 to 15 hp , to fit motor as it isiv)16 to 20 hp , to fit motor as it isv) 21 to 30 hp , to fit motor as it is vi) 31 to 35 hp , to fit motor as it isvii) 36 to 40 hp , to fit motor as it isviii) 41 to 50 hp. , x)bare motor spare parts 10 to 15:bearing , air fan , shaft , bearing plate , motor bush , roter assembly , stud nut kit , nut bolt kit , x)bare motor spare parts 6 to 20:bearing , air fan , shaft , bearing plate , motor bush , roter assembly , stud nut kit , nut bolt kit , x)bare motor spare parts 21 to 50 :bearing , air fan , shaft , bearing plate , motor bush , roter assembly , stud nut kit , nut bolt kit , y)vaccume pump repairing drive out pumpi) 1 to 3 hp , y)vaccume pump repairing drive out pump ii) 4 to 5 hp , motor rewinding i) 1 to 3 hp , motor rewinding ii) 4 to 5 hp , pump opening, repairing, over oiling, fitting & testingi) 1 to 3 hp , pump opening, repairing, over oiling, fitting & testingii) 4 to 5 hp , roter shaft turning & polishing i) 1 to 3 hp , roter shaft turning & polishing ii) 4 to 5 hp , to make vaccume pump bush & baring housing i) 1 to 3 hp , to make vaccume pump bush & baring housing ii) 4 to 5 hp , to fit new pump set i) 1 to 3 hp , to fit new pump set ii) 4 to 5 hp , panel board & starter repairing i) 1 to 3 hp , panel board & starter repairing ii) 4 to 5 hp , z) vaccume pump spare parts 1 to 3 hp :baring , impelor key , pump bush , air fan , sturnut key , baring plate both side , mechanical seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , roter g.m. , fan cover , spacer , baring housing , neck ring , port plate , flage (delevery/ section) , shaft sleve , saction & delivery chember , steter fitted motorbody , tie rod , roter casing , liquid diflector , z) vaccume pump spare parts4 to 5 hp :baring , impelor key , pump bush , air fan , sturnut key , baring plate both side , mechanical seal , gland rope , gland bush , gland plate , roter fitted shaft , latern ring , roter g.m. , fan cover , spacer , baring housing , neck ring , port plate , flage (delevery/ section) , shaft sleve , saction & delivery chember , steter fitted motorbody , tie rod , roter casing , liquid diflector , starter reley i) 6 to 10a. , ii) 9 to 14 a. , iii) 13 to 21 a , iv) 19 to 27 a , v) 21 to 32 a , starter no volt & over load coil , contactor set fulli) s. k. 1 , ii)m.l. 1 , iii) m.l. 2 , iv) m.l. 3 , v) m.l. 4 , vi) m.l. 5 , vii) m.l. 6 , viii) m.l. 7 , ix) m.l. 8 , x) m.l. 9 , xi) m.l. 10 , reley plate (kit) , contactor point kiti) s. k. 1 , ii) m.l. 1 , iii) m.l. 2 , iv) m.l. 3 , v) m.l. 4 , vi) m.l. 5 , vii) m.l. 6 , viii) m.l. 7 , ix) m.l. 8 , x) m.l. 9 , xi) m.l. 10 , i) fuse grip 16 a. , ii) fuse grip 32 a. , iii) fuse grip 63 a. , iv) fuse grip 100 a , v) fuse grip 200 a.. , fuse basei) 16 a. , ii) 32 a. , iii) 63 a. , iv) 100 a. , v) 200 a. , connector plate , i) volt meter 0 440 volt small , ii) volt meter 0 440 volt big , ampear meter , ampear meteri) 0 to 15 a. , ii) 0 to 50 a. , iii) 0 to 100 a. , iv) 0 150 a. , capasitor 1 k.v.a.r. , single phasing preventor , water level guardwith 60 m. wire , on off rotery switch , volt meter / ampere meter switch , nuon indicator lamp , main switch 440 volt three phase , i) 16 a. , ii) 32 a. , iv) 100 a. , v) 200 a. , m.s.e.b. unit i) 32 a. , ii) 63 a. , iii) 100 a. , iv) 200 a. , h.r. c. fuse i) 100 a. , ii) 125 a. , iii) 200 a. , aquazilary coil , timer coil , c.t. coil i) 60 a. , ii) 100 a. , iii) 200 a. , tog tester , multi meter , insulation tester , meger , hand gloves 1 pair (rubber) , insulated rubber matting , to arthing with arthing 300 x 300 x 50 m.m. arthing plate,g i. pipe & arthing wire , to arthing with arthing 450 x 450 x 50 m.m. arthing plate, g i. pipe & arthing wire , arthing wire 14 to 6 guage , starter d.o.l , i) 1 to 5 hp , ii) 5 to 10 hp , iii) star delta auto 10 to 20 hp , vi) star delta auto 21 to 30 hp , v) auto transfarmer starter 20 to 30 hp , vi) auto transfarmer starter 31 to 50 hp , transfarmer coil rewinding with copper wire in transfarmer starter. without returning old copper wire. , change over switch 50 a. 3 phase , change over switch 100 a. 3 phase , change over switch 200 a. 3 phase , buz bar 30 to 50 hp , transfarmer oil , discharge with stainless steel pump shaft and motor suitable for working on 415 v± 10%, 3ph, 50 hz., a.c. supply, cable guard, thrust carbon/fibre bearing to accept entire hydraulic thrust, water proofwinding shall be provided. the pump set shall be suitable for direct coupling. pump shall have suitable suction stainer shall also be provided. 3 core, single/double run copper conductor submersible type flat cable 3 mtr. and 3 pairs of erection clamps. rates per pump upto 20 stages (as per design)submercsible pump set 100mm dia(with polypropelene/ noryl impeller)up to 20 stages1.5 hp , 2.0 hp , 3.0 hp , 4.0 hp , 5.0 hp , submersible pump 150 mm dia (with bronze /stainless(cf8m) impeller) up to 8 stages 1.5 hp , 2.0hp , 3.0hp , 4.0hp , 5.0 hp , 6.0hp , 7.5 hp , submersible pump 150 mm dia (with bronze /stainless(cf8m) impeller) up to 12 stages1hp , 12.5hp , 15hp , submersible pump 150 mm dia (with bronze /stainless(cf8m) impeller) up to 15 stages17.5 hp , 20 hp , 22.5 hp , submersible monoblock (with bronze / stainless steel (cf8m) impeller ) horizontal/vertical upto 3 stages( motor with water lubricated bearing to accept entire hydraulice threst ) 3 hp , 5hp , 7.5 hp , 10 hp , supplying and erecting submersible pumpset 0.75kw/ 1hp with 415v 50 cycles ac supply suitable for 100mm dia borewell . suitable for 10 to 50 lpm discharge at 70 to 20 m and ( max effciency at 52 m. head 30 lpm discharge) & delivery pipe of 32 mmdiameter with a neccssary h. type clamp as per specification no. wp. smp , suppluing and erecting 3 core pvc. insulated flat flexible submersible cable with copper conductor, pvc insulated and pvc sheathed 3core 2.5 sq.mm , 3core 4 sq.mm , 3core 6 sq.mm , 3core 10 sq.mm , providing, suplying & in standard lenghts mdpe pipes. conforming to i.s.o. 4427:1996/with necessary jointing material like mechanical connection i.e. thread/insert joint/quick release coupler joint/compresion fitting joint or flanged joint. ...............etc complete. pn 16sdr 9 20 mm , 25mm , 32mm , 40mm , 50mm , 63mm , 75mm , 90mm , providing, suplying & in standard lenghts hdpe pipes. conforming to i.s.o. 4427:1996/with necessary jointing material like mechanical connection i.e. thread/insert joint/quick release coupler joint/compresion fitting joint or flanged joint. ...............etc complete.6kg 32mm , 40mm , 50mm , cpvc pipe32mm , cpvc pipe 40mm , 50mm , providing isi mark gi pipe with one coupler of following class and dia including all local and central taxces, octroi, inspection charges, transportation to stores etc. complete. is 1239/2004 15 mm dia medium , 20 mm dia medium , 25 mm dia medium , 32 mm dia medium , 40 mm dia medium , 50 mm dia medium , 65 mm dia medium , 80 mm dia medium , 100 mm dia medium , 125 mm dia medium , 150 mm dia medium , lowering, laying, jointing g.i. pipes and specials of following class and dia. including conveyance from stores to site of works, all labour, giving satisfctory hydraulic testing etc. complete. either underground or in vertical position, as directed by engineer in charge. 15 mm dia medium , 20 mm dia medium , 25 mm dia medium , 32 mm dia medium , 40 mm dia medium , 50 mm dia medium , 65 mm dia medium , 80 mm dia medium , 100 mm dia medium , 125 mm dia medium , 150 mm dia medium , providing, supplying isi mark c.i.d/f. reflux valve (non return valve ) with jointing to pipe work(including all hardware and packing) water works quality with jointing to pipe withoutbypass arrangement with gunmetal seat excluding c.c. foundation/structural steel supports. for rating pn 1.6 confirming to is 5312: 1984 50 mm dia , 65 mm dia , 80 mm dia , lowering, laying and jointingin position following cidf reflux valve/ butterfly valve and sluice valve including cast of all labour, jointing material including nut bolts and giving 50 mm dia , 65 mm dia , 80 mm dia , nrv valve gun metal 25 mm , nrv valve gun metal 80 mm , providing and supplying isi standard c.i. flanged / s & s specials including all taxes (central and local) railway freight, insurance, unloading from railway wagon, loading into truck, d.f.specials80 mm to 300 mm dia , supplying and erecting automatic control panel for 3ph,415v ,ac submersible /centrifugal pumpset upto 6 hp consisting of dol starter having relay range 9 14 amp s.p.p.,combined ammeter/voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof encloser with ip 54 protection control panel should offer single phase ,phase reversal ,phase inbalance etc ( similer to lt model no.mu g6/cat no.ss97756) , dol starter supplying and erecting dol starter to operate squirrel cage induction motor working on 380 440 v, 3 ph., 50 hz., with no volt coil, overload element with necessary material & connected to supply etc. comp. starter with original sheet steel encloser. up to 7.5 hp , up to 10 hp , main switch 415v 16a , main switch 415v 32a , main switch415v 63a , s.s. nipple , dual chamber/special water chamber , providing structural steel work in single stanctions composed of rsj chanel etc. with caps, bases, mild steel plates angles, bracket cleats, gusset plates, anchour bolts etc. as per detailed drawing and design or as directed by engineer in charge including cutting, fabricating, hoisting, erecting, fixing, in position making reveted/bolted/welded in connection and one coat of anti corrosive point and over it two coats of oil painting etc. complete. 7.5 hpto 12.5h.p. , above12.5 hpto20h.p. , above 20 hpto25h.p. , above 25 hpto40h.p. , providing structural steel work in single stanctions composed of rsj chanel etc. with caps, bases, mild steel plates angles, bracket cleats, gusset plates, anchour bolts etc. as per detailed drawing and design or as directed by engineer in charge including cutting, fabricating, hoisting, erecting, fixing, in position making reveted/bolted/welded in connection and one coat of anti corrosive point and over it two coats of oil painting etc. complete. , earthing for pumping machinery supplying and erecting earthing with galvanised cast iron earth plate size 60x60x0.6 cm complete with all materials,testing &recording the result as per specification no.ea ep , excavation for foundation / pipe trenches in earth, soil of all types, sand, gravel and soft murum, including removing the excavatedmaterial upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding back filling, etc. complete. lift 0 1.5 m. , excavation for foundation / pipe trenches in hard murum, including removing the excavatedmaterial upto a distance of 50 metres and lifts as below, stacking and spreading as directed, lift 0 1.5 m. , providing and supplying in standard lengths isi mark rigid unplasticised pvc pipes suitable for potable water with unplastised pvc pipes suitable for potable water with solvent cement joints including cost of couplers, as per is specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores/ site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc.complete (selffit type to be jointed with cement solvent). 63 mm dia. pvc 4 kg/ cm² , 75 mm dia. pvc 4 kg/ cm² , 90 mm dia. pvc 4 kg/ cm² , 110 mm dia. pvc 4 kg/ cm² , 140 mm dia. pvc 4 kg/ cm² , lowering, laying and jointing pvc pipes and specials of following class and diameter including cost of conveyance from stores to site of work including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per is code, etc. complete (with cement solvent joint / ring fit joint) 63 mm dia. pvc 4 kg/ cm². , 75 mm dia. pvc 4 kg/ cm² , 90 mm dia. pvc 4 kg/ cm² , 110 mm dia. pvc 4 kg/ cm² , 140 mm dia. pvc 4 kg/ cm² , providing and laying in citu c.c. of of trap / granite/ quartzite/gneiss metal for foundation and bedding including normal dewatering, formwork, compacting and curing, finishing, etc.complete. pcc m 100 for reinstaining of cement road , providing and constructing two taps standpost as per type design with excavation 15 cm thick pcc (1:3:6) bedding 20 mm thick pcc (1:2:4) concrete for platform of 1.75 m dia. with side curb and bucket rest 80 mm dia, heavy duty gi pipe central post duly filled therein with c.c. (1:2:4) 5 m long, 20 mm dia. medium g.i. pipe from point of tapping to standpost additional 20 mm dia g.i. pipe fixed verticaly upto 15 mm dia self closing water taps on brass ferrule etc. complete together with all labour and material charges as per drawing and as directed by engineer in charge when good foundation is available. rate includes draining arrangement by excavating open gutters. , refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, , providing,hosting and fixing in position of approved make high density polyethylene uv stabilized conforming to is 12701 ,water storage tank with necessary connections, testinfg etccomplete 9 prior approval of sample by ex. engineer is necessary before use ) spect. no. as directed by engineer in charg.for 200 to 1000 lit. , for 1000 to 20000 lit. , providing fixing 15mm dia screw down bib stop tap of brass including necessory socket union nut complete (pwd csr 22 23 p.no. 288 i.no. 41.4 , providing and laying in trenches dia cpvc pipeincluding necessary excavation fitting reffilling trenches etc complete including removing existing pipe line if the same in pwd chowky or as directed etc complete 1)for 15 mm dia , 2) for 20 mm dia , 3) for 25 mm dia , 4) for 32 mm dia , 5) for 40 mm dia...

Shri Saibaba Sansthan Trust - Maharashtra

37367762 purchase of dental material for shri saibaba and sainath hospital for the year 2023 24. purchase of dental material for shri saibaba and sainath hospital for the year 2023 24, shri saibaba sansthan trust, shirdi. , stronium chloride 10% w / v r.a.toothpaste 50 gm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , chlorhexiden gluconate gel 15 gm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , pyson gum paint 20 ml , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , aqua caine spray , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , chlorhexiden mouth wash 50ml , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , benzydamine mouthwash , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , base plate ( box ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , stone plaster ( yellow ) qty in kg 3 kg , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , amlexanox oral paste 5% , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , zinc oxide paste ( impression paste ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , alginate for impression ( qty. in kg ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , pain off , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , dycal cement tubes , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plastic cover for rvc sensor , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , 2% lignocaine spray , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , dispersible glass ( small size ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , amalgam powder with mercury , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , h file no. 15 to 40 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , h file no. 10 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file15 to 40 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , glass ionomer restorative cement , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gutta purcha point21mm 15 40 ( demand in box ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gutta purcha point21mm no. 20 ( demand in box ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gutta purcha point21mm no. 30 ( demand in box ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gutta purcha point21mm no. 25 ( demand in box ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , light cure composite enchant 37% phosphoric acidciel , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , single component bonding agent ( light cure composite ) bc plus , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , liq. zytee 15 ml , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , glass inomer luting , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , miracle mix , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , bone cutting burrs ( carbidc ) stright ssw hp 559 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , bone cutting burrs ( carbidc ) stright ssw hp 703 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , bone cutting burrs ( carbidc ) round ssw hp 8 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , bone cutting burrs ( carbidc ) round ssw hp 6 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , protapergutta percha cones ( f1, f2, f3 ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , crown cutting burrs set ( 1set = 14 pices ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , cleaning and lubrication spray ( pan = air spray ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , dental varnish , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , mirror with handle , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , probe , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , twizer , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , kavo spray , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , cautry cutting burs diamond , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , zinc phosphate cement , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , zinc oxide ensunol cement , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , light cure cement kit , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , nsk surgical handpiece , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gas torch , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , hand proteper kit , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , rotery proteper kit , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , paper points ( 15 40 ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , ah plus ( scaler ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , ah plus export pack non e u ( sealar ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , articalating paper , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , cavit , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , r.c.help , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 15 40 ( 25mm length ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 45 80 21mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 45 80 25mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 6 no. , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 8 no. , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , k file 15 no. , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , gic type ix , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , formocrisol , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , g p points 4% 45 80 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , g p points 6% 15 40 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , g p points 6% 45 80 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , hand protaper nih 21mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , hand protaper nih 25mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , matrix bonds 1 ( demand in pkt ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , mta ( demand in pkt ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , spreader ( demand in pkt ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , reamers 15 40 ( demand in pkt ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , reamers 45 80 ( demand in pkt ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , dry socket paste , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , rc cal , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , 26 gauge wire rill ( ss ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , drill bits 1.5mm ( ss ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , drill bits 2mm ( ss ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , imf screws ( 2 x 8mm ) =50, ( 2 x 6 mm ) =30 , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , lag screw ( 2 x 16 ) , ( 2 x 18, ) ( 2.5 x 14 ) , ( 2.5 x 16 ) , ( 2.5 x 18 ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 1.5 x 4mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 1.5 x 6mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 1.5 x 8mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 2 x 6mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 2 x 8mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 2.5 x 8mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 2.5 x 10mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , screws 2.5 x 12mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 1.5mm 20 hole plate , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 1.5mm 4 hole with gap , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2mm 20 hole plate , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2mm 4 hole periorbita , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2mm l shape left , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2mm l shape right , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2.5mm 20 hole plate , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , plates 2.5mm 4 hole with gap , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , self holding screw driver 1.5mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , self holding screw driver 2mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , self holding screw driver 2.5mm , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , wire cutter ( small ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , heisters jaw opener , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , g p solvent ( gutta purcha ) , make 1 or , make 2 or , make 3 or , make 4 or , make 5 , barbed broaches , make 1 or , make 2 or , make 3 or , make 4 or , make 5...

Rural Development Department - Maharashtra

37359420 supplying electrical materials and repair maintenance services at. grampanchayat ambi tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) etc...

Rural Development Department - Maharashtra

37334780 supplying electrical materials and repair maintenance services at. grampanchayat somatane., tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Rural Development Department - Maharashtra

37318891 supplying electrical materials and repair maintenance services at. grampanchayat nighoje tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Directorate Of Municipal Administration - Maharashtra

37282913 supplying street light maintenance material for municipal council ahmedpur , incandescent bulb 60 w , 36 watt t4 4 feet , 24 watt t5 , hpsv lamp 150 w , hpsvlamp 250 w , led square / circular 16 to 20w downlighter , 5w 8 wled bulb , 10w 12w led bulb , 14 w led bulb , 18 w led bulb , t4 choke copper , t4 choke electronic , t5 choke copper , t5 choke electronic , t4 starter , t4 side holder , t5 side holder , metal halide lamp 250 w double ended , metal halide lamp 400 w double ended , condenser for 150 w mv / sv / mh lamp , condenser for 250 w mv / sv / mh lamp , condenser for 400 w mv / sv / mh lamp , ignitor for 70 / 150 / 250 / 400 w hpsv lamp , electronic ignitor for 70 / 150 / 250 / 400 w metal halide lamp , copper choke for80w 150 w hpsv / mv / mh lamp , copper choke for250 w hpsv / mv / mh lamp , copper choke for 400 w hpsv / mv / mh lamp , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block / sunmica block of suitable size , supplying and erecting modular type telephone socket one gangwith safety shutter isi mark approved make duly erected on provided plate and box with wiring connections complete. , fan condenser 2.5 mf , fan clamp , fan hook , electronic fan regulator for 600 / 900 / 1200 / 1400 mm sweep fan , cabinfan 300 mm ( complete ) , ceiling fan 900 mm with regulator ( complete ) , ceiling fan 1200 mm with regulator ( complete ) , desert air cooler 12 exhaust fan with 50 ltr capacity tank , desert air cooler 15 exhaust fan with 68 ltr capacity tank , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps & with dual function cartritge with output of purified water 2 ltr / min with activated carbon filter and softener operating on 230 v single phase a.c. supply. , rewinding of cabin fan 300 ( with 1 year guarantee ) , rewinding of ceiling fan 900 ( with 1 year guarantee ) , rewinding of ceiling fan 1200 ( with 1 year guarantee ) , 12 exhaust fan rewinding of desert air cooler ( with 1 year guarantee ) , 15 exhaust fan rewinding of desert air cooler ( with 1 year guarantee ) , 20 mm pvc conduit with necessary accessories like saddle, screws. , 25 mm pvc conduit with necessary accessories like saddle, screws. , pvc trunking ( pvc casing ncapping ) of size 20 mm with accessories , pvc trunking ( pvc casing ncapping ) of size 25 mm with accessories , point wiring for light / fan / bell in 20 mm rigid pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw / sw , pvc junction box 2 way / 3 way / 4 way , ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6a , 1 way 5 ampere switch / 2 way 5 ampere switch , 3 pin 5 ampere socket , , 16 ampere ( 240 v ) switch , 16 ampere ( 240 v ) socket , wooden board 12 * , supplying & erecting on line ups pure sine wave of 5 kvacapacity complete with standard features, along with necessary smf batteries for 30 mins battery backup, as per specification no. ap ups ( including labour charges ) , supplying and erecting 12 v / 135ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete ( including labour charge ) , supplying, installing, testing & commissioning of 2500 va digital pure sine wave inverter based on igbt technology single phase 230v, 50 hz complete as per specification no. ap inv ( without batteries ) ( including labour charges ) , 1 sqmm. flexible wire , 1.5 sqmm. flexible wire , 2 sqmm. flexible wire , 2 pole 250 v 12 amp contactor , 2 pole 250 v 32 amp contactor , 4 pole 440 v 16 amp contactor , 4 pole 440 v 40 amp contactor , double pole isolator 40 amp , triple pole isolator 40 amp , triple pole isolator 63 amp , four pole isolator 40 amp , four pole isolator 63 amp , pole above 6 mtr dismantling , mcb 6 to 32 amp ( lightning ) , mcb 40to 63 amp ( lightning ) , mcb 6 to 32 amp ( motor / power ) , mcb 40 to 63 amp ( motor / power ) , jcb / breaker excavation for onsite cable trench work , supplying and erectingrolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj , supplying and erecting fibre / pvc spacers for l.t. overhead line 3 to 5 conductors complete erected , supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.l. strips, nuts and bolts, complete. , supplying and erectingaluminium bobbin with g.l. strip, nuts complete , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.l. stay wire7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation , ??.??. ?????? ????? , ???? ????? ? ??. x ? ??. , ???? ????? ?? ???? ????? ??????? ? ??. x ? ??. , making trench in soft soilof suitable width and depth as per is for laying provided l.t cable up to 25 sq mm complete. as per specification no. cw exn ctr ( inclusing labour charges ) , making the trench in hard murum / tar roadof suitable width and depth as per is for laying provided l.t cable up to 10 sq.mm.complete. as per specification no. cw exn ctr , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep ( including labour charges ) , 20 ft staircase set , combination plier , screw driver , tester , ring pana sett / hand tools kit , patti pana set / hand tools kit , tong tester , megger meter , extention box ( including 4 plug ) , hydrolic aluminium body 40 ft staircase set ( panel type ) , lugdje fixing machine , drill machine , small capacity blower , small capacity cutter , 15 mm copper pipe , 10 mm copper pipe , 5 mm copper pipe , hand gloves , labour charges for repairing central pole light , labour charges for repairing central pole light , suplying g.i. bracket ( 3 / 4 to 3 / 2 ) inch , supplying cement pole clamp with nut bolt , supplying rsj pole clamp with nut bolt , labour charges for repairing high pole...

Central Railway - Maharashtra

37275826 supply of water boiler of 30 ltrs. capacity for hot buffet lhb type coaches without water filter , generally conforming to is:3412 along with control box & necessary plumbing & tap arrangement on a common base plate conforming to rcf specification no. edts 118, rev. e with am 2, cor 1, drg. no. lh 72211, alt. b. material shall procure from oem or his authorized dealer. make / brand shrill refrigeration , s.d engineers, spectrum scientific, vishal gas service, pooja entps., super refrigeration only....

Ministry Of Defence - Maharashtra

37222606 bids are invited for installation and commissioning of epbax system cable , epbax system , key phone kts , mdf box with crone , crone with base plate , hola display phone , rj 11 connector , installation charges with one year amc , cable running labour , rj 11 intercom open box total quantity : 24396...

Municipal Council - Maharashtra

37202221 supplying electrical materials for streetlight repair, installation of high mast pole and streetlight pole, light fitting and other electrical works as required by mangalvedha municipal council electricity department. 1 2x1.5 sq.mm frlsh copper pvc insulated wire 2 2x2.5 sq.mm frlsh copper pvc insulated wire 3 2x4 sq.mm frlsh copper pvc insulated wire 4 2x6 sq.mm frlsh copper pvc insulated wire 5 2x10 sq.mm frlsh copper pvc insulated wire 6 3x2.5 sq.mm frlsh copper pvc insulated wire 7 3x4 sq.mm frlsh copper pvc insulated wire 8 3x6 sq.mm frlsh copper pvc insulated wire 9 3x10 sq.mm frlsh copper pvc insulated wire 10 4x16 sq.mm frlsh copper pvc insulated wire 11 1 sq.mm ( 32 no. x0.20mm dia. ) 3 core flexible multi stranded copper 12 wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires 13 xlpe insulated unarmoured cable 1100 v 1 core 70 sq. mm. aluminium conductor 14 xlpe insulated unarmoured cable 1100 v 1 core 95 sq. mm. aluminium conductor 15 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium 16 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor 17 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor 18 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 4 sq. mm. aluminium conductor 19 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 6 sq. mm. aluminium conductor 20 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 10 sq. mm. aluminium conductor 21 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 16 sq. mm. aluminium conductor 22 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 25 sq. mm. aluminium conductor 23 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½ core 70 sq. mm. aluminium conductor 24 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor 25 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3½core 240 sq. mm. aluminium conductor 26 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 6 sq. mm. aluminium conductor 27 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminium conductor 28 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductor 29 fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor 30 modular type switch 6a / 10a 31 modular type switch 16a 32 modular type bell push with indicator 2 modules 6a / 10a 33 modular type two way switch 6a / 10a ( 2 module 34 modular type switch 16 / 20 a with indicator 35 modular type d.p. switch 32a with indicator 36 modular type 32a, dp key tag switch with key tag 37 modular type 3 pin 6a multi socket with safety shutter 38 modular type 3 pin 6 / 16a multi socket with safety shutter 39 modular type 6 / 16a fuse 40 modular type ( two module ) electronic step regulator for fan 41 modular type blanking plate one module 42 modular type blanking plate two module 43 ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. 44 adaptor for lamp holder 45 pvc surface modular switch box with double mounting plate for 2module 46 pvc surface modular switch box with double mounting plate for 3module 47 pvc surface modular switch box with double mounting plate for 4 module 48 pvc surface modular switch box with double mounting plate for 6module 49 pvc surface modular switch box with double mounting & front plate for 8 module 50 pvc surface modular switch box with double mounting plate for 12module 51 pvc surface modular switch box with double mounting plate for 16 / 18 module 52 concealed type modular switch box with double mounting plate for 1 module 53 concealed type modular switch box with double mounting plate for 2 module 54 concealed type modular switch box with double mounting plate for 3 module 55 concealed type modular switch box with double mounting plate for 4 module 56 concealed type modular switch box with double mounting plate for 6 module 57 concealed type modular switch box with double mounting plate for 8 module 58 concealed type modular switch box with double mounting plate for 12 module 59 concealed type modular switch box with double mounting plate for 16 / 18 module 60 white footlight with 4 modules concealed modular box and led lights 61 16 / 20 / 25 a starter ( modular range ) 2 module 62 6 to 32 a, 10ka, spmcb suitable to fix in 1 module 63 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module 64 pvc surface modulardouble mounting plate 1 module 65 pvc surface modulardouble mounting plate 2 module 66 pvc surface modulardouble mounting plate 3 module 67 pvc surface modulardouble mounting plate 4 module 68 pvc surface modulardouble mounting plate 6 module 69 pvc surface modulardouble mounting plate 8 module 70 pvc surface modulardouble mounting plate 12 module 71 pvc surface modulardouble mounting plate 16 / 18 module 72 hms pvc conduit frls grade 25 mm dia 73 hms pvc conduit frls grade 32 mm dia. 74 single pole and neutral distribution board ( spndb ) , with 2 ways for incoming and 6 ways ( 6 poles ) for outgoing sp mcbs 75 single pole and neutral distribution board ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs 76 spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka 77 spmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka 78 dpmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka 79 2 pole rccb 40a 80 2 pole rccb 63a 81 4 pole rccb 16 / 25a 82 copper earth plate size 30 x 30 x 0.315 cm complete 83 energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm 84 pre wired box type fitting / batten suitable for 4 feet, t8 led tube light 85 5w 7w, 230v integral type led lamp 86 10 12w, 230v integral type led lamp 87 14w, 230v integral type led lamp 88 led square / circular max. 11 w down lighter / panel light 89 led square / circular max. 18 w down lighter / panel light 90 led strip light 5m length max. 45 w ip20 class 91 street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length 92 street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length 93 16 amp. 3 pin plug top bakelite type 94 single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time ofhrs. based on insulated gate bipolar transistor ( igbt ) technology complete 95 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty 96 cabin fan of a.c. 230 v. 50 cycles 250 mm. / 300 mm. sweep 97 cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep 98 fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm 99 spmcb 0.5a to 5a, c series with rated short circuit breaking capacity ( icn ) 10ka 100 tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka 101 triple pole isolators only switch version of miniature circuit breaker of 40a 102 triple pole isolators only switch version of miniature circuit breaker of 63a 103 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , 104 3 pole mccb, 415v, 200a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , 105 four pole isolators only switch version of miniature circuit breakers of 63a 106 mcb type change over switch 2 pole, 40 a 107 mcb type change over switch 4 pole, 63a with 3 positions 108 triple pole and neutral distribution board ( tpndb ) , spmcb of 8 ways / phase 24 poles 109 triple pole and neutral distribution board ( tpndb ) , sp / tp mcbs total 8 ways / 24 poles 110 triple pole and neutral distribution board ( tpndb ) , 3 pole / 4 pole mccb as incomer & outgoing sp mcb ( 36 poles ) or tp mcb of 12 ways ( 36 poles ) , 111 electronic type cordless call bell 112 condenser 2.5 micro farad for ceiling fan 113 anchor type fastener fan hook 114 fan hook box of 10 mm m.s. round 115 pvc trunking ( pvc casing n capping ) of size 25 mm 116 pvc trunking ( pvc casing n capping ) of size 32 mm 117 pvc trunking ( pvc casing n capping ) of size 40 mm 118 iron clad cut out hc type 415v, 32a 119 iron clad cut out hc type 415v, 63a 120 iron clad cut out hc type 415v, 100a 121 iron clad cut out hc type 415v, 200a 122 led street light fitting 18 to 22w ip65 & ik08 class 3 years warranty 123 led street light fitting 60w ip65 & ik08 class3 years warranty 124 led street light fitting 70 75w ip65 & ik08 class 3 years warranty 125 led street light fitting 100 110w ip65 & ik08 class 3 years warranty 126 led flood light fitting max. 100w ip65 & ik07 class 3 years warranty 127 led flood light fitting max. 120w ip65 & ik07 class 3 years warranty 128 led flood light fitting max. 195w ip65 & ik07 class 3 years warranty 129 c 10 battery with capacity of 12v, 40 ah with duty cycle 10 12 hrs. 130 c 10 battery with capacity of 12 v, 75 ah with duty cycle 10 12 hrs. 131 two pole power contactor 230 v, 32 a 132 four pole power contactor 430 v, 40 a 133 programmable digital almanac timer microcontroller based 134 5 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 135 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 136 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f 137 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 200 mm a / f, top 100 mm a / f 138 galvanised 1000mm single arm sword type bracket with frp dome and ball 139 galvanised 1000mm double arm sword type bracket with frp dome and ball 140 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures 141 g.i. pipe ‘a’ class 40 mm dia. 142 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe 143 pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials 144 making trench in hard murum / tar road having 0.75 m depth and minimum 0.3mtr width 145 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 146 making cement concrete foundation in 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing for complete. ( pole muffing or any other purpose ) . 147 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 3 to 5m octagonal / conical gi pole ) . 148 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 149 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 150 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal / conical gi pole ) . 151 gi sheet 1 mm ( 20 swg ) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 152 supplying and erecting rolled steel joist ( girder ) pole 175 x 85 mm ( 19.6 kg / m ) with provided base plate in provided foundation as per specification no. ohpl / rsj 153 supplying and erecting rolled steel joist ( girder ) pole 100 x 116 mm ( 23 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 154 supplying and erecting rolled steel joist ( girder ) pole 200 x 100 mm ( 25.9 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 155 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm. complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 156 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm.complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 157 supplying and erecting 3 phase 4 core 16 sq.mm. ( 3x16+1x25 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 158 supplying and erecting 3 phase 4 core 25 sq.mm. ( 3x25+1x25 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 159 supplying and erecting 3 phase 4 core 95 sq.mm. ( 3x95+1x70 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 160 supplying and erecting 3 phase 5 core 16 sq.mm. ( 3x16+1x25+1x16 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 161 supplying and erecting 3 phase 5 core 70 sq.mm. ( 3x70+1x50+1x16 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 162 supplying and erecting 6 way ab cable distribution box on provided pole with necessary accessories as per specification no. oh abc / jbs 163 supplying and erecting 9 way ab cable distribution box on provided pole with necessary accessories as per specification no. oh bc / jbs 164 supplying and erecting 12 way ab cable distribution box on provided pole withnecessary accessories as per specification no. oh abc / jbs 165 10kw, 3 x 3.3 kw ac electric vehicle charger ( suitable for 2 / 3 / 4 wheeler ) having minimum ik08 / ip 54 protection suitable for three phase, 415v ac, 50hz incoming and 3 nos. output as per iec 60309 industrial sockets having capacity of outputcurrent of 16a 240v ac at each socket 166 supplying and installation of solar pv module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 kw solar pv module. ( approx. 35 sq. mtr. pv module area ) . 167 reel insulator 168 “c” clamp bolts and nut 169 khekada clamp bolts and nut 170 pin type lt medium insulator 100 mm x 62 mm dia. with suitable g.i. spindle, nut, bolts 171 aluminium bobbin with g.i. ( shackle ) strip, nuts 172 g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 8 swg, g.l. stay rod 20 mm x 1.8 m length and pole clamps 173 pole clamp made from 50 x 10 mm ms flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 174 ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 175 c type ( half ) clamps for pole made from 50 x 6 mm flat for fixing cross arms by means of 15 mm dia. bolts and nuts painted with one coat of red oxide and two coats of aluminium paint. 176 telephone copper cable 2 pair with 0.5 mm dia. laid in provided pvc 177 fuse wire 63amap 178 35x8 screw 179 25x8 screw 180 rawl plug 181 20x25 cm sanmaik board 182 8x10 cm sanmaik board 183 electrical wiring labour coast 184 high speed electric drill machine 185 copper pin type lugs 10mm2 186 copper pork type lugs 10mm2 187 copperterminal type lugs 10mm2 188 aluminum lugs 70mm2 189 aluminum lugs 12mm2 190 crimping tools 191 taparia 1022 home tool kit – 1022 by taparia | sku: t02 487 192 meco 36 auto 400a ac / dc digital clamp meter 36 auto by meco | sku: t13 060 193 taparia socket set ( pack of 23 ) 194 taparia kbhm9l allen key set 195 taparia 1812 n double ended ring spanners set ( pack of 12 ) 202 short time delay circit with ic 55 ( for linr reactor ) 203 insulation tape 204 panel box2x2.5 standred 205 solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 100 wp, 12v 206 solar led street light luminarire assembly 207 distilled water 208 led street light driver 20 25watt 209 led street light driver 25 30watt 210 led street light driver 36watt 211 led street light driver 40watt 212 led street light driver 60watt 213 led street light driver 70 75watt 214 led street light driver 100 120watt 215 led street light driver 120 150watt...

Directorate Of Municipal Administration - Maharashtra

37201904 to invite rates of non csr items for evection of 9 mtr solar high mast under municipal council gadchiroli 2 supplying and erecting 9m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising handel unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm.flexible copper cable with lantern carriage assembly suitable for its control gear box, lightning arrestor, arrangement for fixing, high mastshould be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/ hm (excluding luminaries) 3 supplying, installing, testing and commissioning of solar power pack with interconnecting wires / cables up to 12 v pure sine wave solar power inverter (thd<3%), spv modules 330 wp x 06 nos.),and other electronics,accessorie complete with 5 years on site warranty and fully comprehensive maintenance contract as per specification no. esd rt ofg 4 supplying and erecting semi integrated solar led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 7000 lumens, min. efficacy of 140 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification nofg odf/fls2. ...

Western Railway - Maharashtra

37193393 auction sale of 98050114 scrap released p way rail fittings such as released slide chairs, joggle fish plates, fish plates, junction fish plates, bearing plates, special bearing plates, ms acb plates, mscb plates, base plates, gauge tie plates, strecher bars, gluid joints with without nut, bolts. tie bars and fiber attachments fiber attachments, etc. of sorts and sizes, rusty, broken and damaged, unserviceable for rly. use, loading by purchaser, [custodian dms mm]. note: this is a reform lot against 0906280223 and 0907270323...

Tata Memorial Centre - Maharashtra

37174900 item rate running contract for annual electrical works and supply of electrical items for the year 2023 24 at actrec 1 point wiring 1.1 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.2 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.3 primary point wiring as 1.1 , modular 2 module fan regulator 250w 1.4 sitc wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvcinsulated copper conductor single core cable etc. as required. 1.5 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.6 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.7 primary point wiring as per 1.5 modular 2 module fan regulator 250w 1.8 sitc of wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5sq.mm frls pvc insulated copper conductor single core cableetc. as required. 2.1 fan hookfabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only supply ) 2.2 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only labour ) 2.3 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( composite ) 2.4 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only supply ) 2.5 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only labour ) 2.6 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners complete in all respects. ( composite ) 2.7 supply of fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( only supply ) 2.8 fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18 inch long etc. complete in all respect. ( only labour ) 2.9 supply & fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( composite ) 3 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed steel conduit as required. 3.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 3.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 3.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 3.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 3.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 3.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 3.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 4 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. 4.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 4.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 4.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 4.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 4.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 4.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 4.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 4.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 4.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 4.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 4.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 6.1 supply & fixing of casing capping of following suitable size with screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. complete as per instructions of eic. 6.1.1 half inch ( only supply ) 6.1.2 half inch ( only labour ) 6.1.3 half inch ( composite ) 6.1.4 threefouth inch ( only supply ) 6.1.5 threefouth inch ( only labour ) 6.1.6 threefouth inch ( composite ) 6.1.7 1inch ( only supply ) 6.1.8 1inch ( only labour ) 6.1.9 1inch ( composite ) 6.1.10 1.25inch ( only supply ) 6.1.11 1.25inch ( only labour ) 6.1.12 1.25inch ( composite ) 6.1.13 1.50inch ( only supply ) 6.1.14 1.50inch ( only labour ) 6.1.15 1.50inch ( composite ) 6.1.16 2.0 inch ( only supply ) 6.1.17 2.0 inch ( only labour ) 6.1.18 2.0 inch ( composite ) 7.1 fixing of pvc conduit / truncking. supply & fixing of pvc rigid conduit of following suitable size with spacers & saddles screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. compete as per instruction of eic. 7.1.1 12.5 mm ( only supply ) 7.1.2 12.5 mm ( only labour ) 7.1.3 12.5 mm ( composite ) 7.1.4 20 mm ( only supply ) 7.1.5 20 mm ( only labour ) 7.1.6 20 mm ( composite ) 7.1.7 25 mm ( only supply ) 7.1.8 25 mm ( only labour ) 7.1.9 25 mm ( composite ) 7.1.10 32 mm ( only supply ) 7.1.11 32 mm ( only labour ) 7.1.12 32 mm ( composite ) 7.1.13 40 mm ( only supply ) 7.1.14 40 mm ( only labour ) 7.1.15 40 mm ( composite ) 7.1.16 50 mm ( only supply ) 7.1.17 50 mm ( only labour ) 7.1.18 50 mm ( composite ) 7.2 providing & fixing pvc trucking of following sizes along with all accessories complete in all respect, all as directed by o i c, es. 7.2.1 50 x 50 x 2 mm ( only supply ) 7.2.2 50 x 50 x 2 mm ( only labour ) 7.2.3 50 x 50 x 2 mm ( composite ) 7.2.4 100 x 50 x 2 mm ( only supply ) 7.2.5 100 x 50 x 2 mm ( only labour ) 7.2.6 100 x 50 x 2 mm ( composite ) 8.1 laying of bunch of wires. supplying & pulling wires with 1.5 sq. mm solid / stranded copper insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.1.1 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.2 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.3 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.4 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.5 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.6 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.7 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.8 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.9 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.10 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.11 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.12 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.13 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.14 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.15 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2 supplying & pulling wires with 2.5 sq. mm solid / stranded copper pvc insulated wire with kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.2.1 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.2.2 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.2.3 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2.4 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.5 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.6 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.7 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.8 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.9 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.10 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.11 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.12 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.13 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.14 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.15 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.3 supplying & pulling wires with 4 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.3.1 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.2 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.3 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.4 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.5 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.6 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.7 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.8 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.9 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.10 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.11 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.12 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.13 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.14 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.15 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4 supplying & pulling wires with 6 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.4.1 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.2 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.3 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.4 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.5 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.6 same as item no 8.4 but for 3x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.7 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.8 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.9 same as item no 8.4 but for 4x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.10 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.11 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.12 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.13 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.14 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.15 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 9.1 concealing of pipe supplying & laying isi mark ms pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.1.1 same as item no 9.1 but for 20 mm size ( only supply ) 9.1.2 same as item no 9.1 but for 20 mm size ( only labour ) 9.1.3 same as item no 9.1 but for 20 mm size ( composite ) 9.1.4 same as item no 9.1 but for 25 mm size ( only supply ) 9.1.5 same as item no 9.1 but for 25 mm size ( only labour ) 9.1.6 same as item no 9.1 but for 25 mm sizee ( composite ) 9.1.7 same as item no 9.1 but for 32 mm size ( only supply ) 9.1.8 same as item no 9.1 but for 32 mm size ( only labour ) 9.1.9 same as item no 9.1 but for 32 mm sizee ( composite ) 9.2 supplying & laying isi mark gi pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.2.1 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only supply ) 9.2.2 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only labour ) 9.2.3 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( composite ) 9.2.4 same as item no 9.2, 25 mm dia gi same as above ( only supply ) 9.2.5 same as item no 9.2, 25 mm dia gisame as above ( only labour ) 9.2.6 same as item no 9.2, 25 mm dia gisame as above ( composite ) 9.2.7 same as item no 9.2, 32 mm diagi same as above ( only supply ) 9.2.8 same as item no 9.2, 32 mm diagi same as above ( only labour ) 9.2.9 same as item no 9.2, 32 mm diagi same as above ( composite ) 9.3 supplying & laying isi mark pvc rigid pipe of suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.3.1 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only supply ) 9.3.2 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only labour ) 9.3.3 same as item no 9.3 as above but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( composite ) 9.3.4 same as item no 9.3 but 25 mm dia pvc conduit ( only supply ) 9.3.5 same as item no 9.3 but 25 mm dia pvc conduit ( only labour ) 9.3.6 same as item no 9.3 but 25 mm dia pvc conduit ( composite ) 9.3.7 same as item no 9.3but 32 mm dia pvc conduit ( only supply ) 9.3.8 same as item no 9.3but 32 mm dia pvc conduit ( only labour ) 9.3.9 same as item no 9.3but 32 mm dia pvc conduit ( composite ) 9.4 in general same as item no 9.3 but as applicable for concealing the pipes in marble / granite flooring or wall, of following suitable sizes. 9.4.1 20 mm dia ( only supply ) 9.4.2 20 mm dia ( only labour ) 9.4.3 20 mm dia ( composite ) 9.4.4 25 mm dia ( only supply ) 9.4.5 25 mm dia ( only labour ) 9.4.6 25 mm dia ( composite ) 9.4.7 32 mm dia ( only supply ) 9.4.8 32 mm dia ( only labour ) 9.4.9 32 mm dia ( composite ) 9.4.10 38 mm dia ( only supply ) 9.4.11 38 mm dia ( only labour ) 9.4.12 38 mm dia ( composite ) 10.1 area lighting fittings covers supply fixing / replacement of glass / acrylic covers for various street light / flood light / area lighting or any such lighting fittings having same grade of glass / acrylic all as directed by o i c, es. agency is requested to see the sample first and adequate / suitable replacement sall be done. removed covers / parts shall be returned to actrec as it is. 10.1.1 for post top lantern ( only supply ) 10.1.2 for post top lantern ( only labour ) 10.1.3 for post top lantern ( composite ) 10.1.4 any other equivalent for item no 10.1 application but non standred lighting fixture ( only supply ) 10.1.5 any other equivalent for item no 10.1 application but non standred lighting fixture ( only labour ) 10.1.6 any other equivalent but for item no 10.1 appplication non standred lighting fixture ( composite ) 11.1 pvc flexible conduit supply & laying / replacement of pvc flexible conduit conforming to isi standards & approved make with required number of coupling, pvc bushes, check nuts etc complete all as per instruction of eic. in case of replacement, removed parts, items etc. shall be returned to actrec as it is. 11.1.1 same as above 20 mm dia same as above ( only supply ) 11.1.2 same as above 20 mm diasame as above ( only labour ) 11.1.3 same as above20 mm dia same as above ( composite ) 11.1.4 same as above 25 mm dia same as above ( only supply ) 11.1.5 same as above 25 mm dia same as above ( only labour ) 11.1.6 same as above 25 mm dia same as above ( composite ) 11.1.7 same as above 32 mm dia same as above ( only supply ) 11.1.8 same as above 32 mm dia same as above ( only labour ) 11.1.9 same as above 32 mm dia same as above ( composite ) 11.1.10 same as above 40 mm dia same as above ( only supply ) 11.1.11 same as above 40 mm dia same as above ( only labour ) 11.1.12 same as above 40 mm dia same as above ( composite ) 11.1.13 same as above 50 mm dia same as above ( only supply ) 11.1.14 same as above 50 mm dia same as above ( only labour ) 11.1.15 same as above 50 mm dia same as above ( composite ) 12.1 dismentling dismantling / removing the existing light, fan, bell, independent plug point, wiring of all types with accessories, switch boards etc to the satisfaction of in charge. all dismantled / removed / scrap material to be handed over to engg. dept as it is. ( only labour ) 12.2 dismantling the existing mains wires of all sizes, make running through pvc casing capping / pipes / ms conduits including casing capping / pvc pipes / ms pipes / gi pipes / hgdwc pipes / pvc or metal trunking etc. ( only labour ) 12.3 dismantling the cables of following sizes without damaging it with glands, cable end boxes, earthing, saddles, spacers & clamps etc & cleaning the surface area & hand over to engg. in –charge. ( only labour ) 12.3.1 1.5 sq. mm to 10 sq. mm ( only labour ) 12.3.2 16 sq. mm to 70 sq. mm ( only labour ) 12.3.3 above 70 sq. mm ( only labour ) 12.4 dismantling of distribution board / bus bar irrespective of size, capacity / ways etc complete with angle iron frame & making the site clear by refilling the holes etc. & finishing matching to background and handing over it to actrec as it is. ( only labour ) 12.5 dismantling ceiling fan, exhaust fan, wall / cabin fan / fluorescent lamp / night lamp etc. with accessories, gi down rod, frame etc & making the site clear & finishing matching to background and handing over the items to actrec as it is. ( only labour ) 12.6 dismantling existing electric geyser / storage type water heater irrespective of size, make, including brackets, grouting bolts etc refilling the holes with cement mortar & making the site clear and handing over it to actre as it is. ( only labour ) 12.7 dismantling of smoke detector / response indicator / bg / circuit isolator / ahu cut off, putting insulation on exposed ends etc and handing nover it t actrec as it is. ( only labour ) 13.1 rewinding rewinding of table / wall / pedestal / exhaust fan up to 300 mm / dip freezer / any similar application motor etc. of all types & make including overhauling, minor repairs, testing for the original speed including transportation, removal from point of fault & refiitting of the same after repairs for inclusive cost as mentioned in the following item nos. all the items removed while repairs / replacements except copper coils shall be handed over / returned to e i c as it is. ( composite ) 13.2 all general gidelines as per item no 13.1 but for rewinding of exhaust fan above sweep 300 mm. ( composite ) 13.3 all general guide lines as per item no 13.1 but for rewinding of ceiling fan motor of all makes and types including overhauling, including minor repairs, & testing at site of following sizes. all the removed / replaced parts / items shall be returned / handed over to e i c, es. 13.3.1 900 mm sweep ( composite ) 13.3.2 1200 mm sweep ( composite ) 13.3.3 1400 mm sweep ( composite ) 13.4 rewinding of single / three phase motors rewinding of electric single phase / three phase motors not covered in item no 13.1 and 13.3, winding with copper wire, overhauling with minor repairs along with the replacement of minor parts, testing for the original speed & guarantee of minimum 6 months, having heneral guidelines as per itam no 13.1 and 13.3, allas per the instructions of e i c, es for inclusive cost as mentioned in the folloeing various items nos. 13.4.1 motors up to onefourth hp single phase. ( composite ) 13.4.2 motors up to half hp single phase. ( composite ) 13.4.3 1 hp single phase. ( composite ) 13.4.4 2 hp single phase ( composite ) 13.4.5 single phase 3 hp ( composite ) 13.4.6 up to 1 hp 3 phase ( composite ) 13.4.7 2 hp 3 phase ( composite ) 13.4.8 3 hp 3 phase ( composite ) 13.4.9 5 hp 3 phase ( composite ) 13.4.10 7.5 hp 3 phase ( composite ) 13.4.11 10 hp 3 phase ( composite ) 13.4.12 12.5 hp 3 phase ( composite ) 13.4.13 15 hp 3 phase ( composite ) 13.4.14 20 hp 3 phase ( composite ) 13.4.15 25 hp 3 phase ( composite ) 13.4.16 30 hp 3 phase ( composite ) 13.4.17 40 hp 3 phase ( composite ) 13.4.18 45 hp 3 phase ( composite ) 13.4.19 50 hp 3 phase ( composite ) 13.4.20 60 hp 3 phase ( composite ) 13.4.21 5 hp submersible pump, 3 ph. ( composite ) 13.4.22 3 hp submersible pump 3 ph ( composite ) 13.4.23 2 hp submersible pump 3 ph ( composite ) 13.4.24 2 hp submersible pump 1 ph ( composite ) 14.1 bearings replacing the worn out / unservicible existing ball of approved make of single phase three phase electric motor / other relevent applications of all types with proper alignment of shaft, greasing / oiling etc & testing at site sll as per the instructions of e i c, es. removed / replaced bearings shall be handed over to e i c, es as it is. ( gate pass / challans are to te submitted to e i c, es each time ) 14.1.1 2 hp to 3 hp ( only supply ) 14.1.2 2 hp to 3 hp ( only labour ) 14.1.3 2 hp to 3 hp ( composite ) 14.1.4 4 hp to 7.5 hp ( only supply ) 14.1.5 4 hp to 7.5 hp ( only labour ) 14.1.6 4 hp to 7.5 hp ( composite ) 14.1.7 10 hp to 20 hp ( only supply ) 14.1.8 10 hp to 20 hp ( only labour ) 14.1.9 10 hp to 20 hp ( composite ) 14.1.10 25 hp to 30 hp ( only supply ) 14.1.11 25 hp to 30 hp ( only labour ) 14.1.12 25 hp to 30 hp ( composite ) 14.1.13 35 hp to 40 hp ( only supply ) 14.1.14 35 hp to 40 hp ( only labour ) 14.1.15 35 hp to 40 hp ( composite ) 14.1.16 45 hp to 50 hp ( only supply ) 14.1.17 45 hp to 50 hp ( only labour ) 14.1.18 45 hp to 50 hp ( composite ) 14.1.19 60 hp to 75 hp ( only supply ) 14.1.20 60 hp to 75 hp ( only labour ) 14.1.21 60 hp to 75 hp ( composite ) 14.2 bearings / bushings / rotors 14.2.1 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only supply ) 14.2.2 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only labour ) 14.2.3 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site. refer guidelines as per item no 14.1 ( composite ) 14.2.4 replacement of shaft for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc ( only labour ) refer guidelines as per item no 14.1 as applicable for this item. 14.2.5 replacement of wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc.refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.6 replacement of non wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. 14.2.7 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( only supply ) 14.2.8 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item ( only labour ) 14.2.9 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.10 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only supply ) 14.2.11 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only labour ) 14.2.12 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( composite ) 14.2.13 painting of old fans, tube lights fixtures, motors or anyh other such application etc as decided and directed by e i c, es with enamel paint after coat of red oxide etc. ( note: this item is applicable only when specifically required for small / midium size erquipment coverd in section no 14. painting included in overhauling or repairs of any electrical equipment / instrument / machine does not come under this. ) ( composite ) 14.2.14 repairing of domestic mixer / grinder / blender or any other eqvuivalant domestic applience etc that includes replacement of indicators, switches, couplers, oiling, general servicing, or any other relvant spare part etc for all manufactures, all as per instructions of engineer in charge. replaced material shall be brought back & shall be submitted to e i c, whereever applicable ( composite ) . 14.2.15 all as per item no 14.2.14 but for replacement of bearing / bushings / blades etc. ( composite ) 14.2.16 all general guidelines as per item no 14.2.14 but for tea kettle excluding heating coil. ( composite ) 14.2.17 replacement of pump impeller ( composite ) 14.2.18 replacement of impeller for 3 hp pump ( composite ) 14.2.19 replacement of impeller for 5 hp pump ( composite ) 14.2.20 replacement of cooling fan for motor up to 2hp. 14.3 capacitors 14.3.1 replacing the defective capacitor of table fan / wall fan / pedestal fan / ceiling fan / dip freezer motor / street light fittings / fluorescent tube fittings or any other smilar application etc & testing at site. general guidelines for replacement shall be as per item no 14.1 as applicable, all as per instructions and as directed by e i c, es 14.3.1.1 1.5 mfd ( only supply ) 14.3.1.2 1.5 mfd ( only labour ) 14.3.1.3 1.5 mfd ( composite ) 14.3.1.4 2.5 mfd ( only supply ) 14.3.1.5 2.5 mfd ( only labour ) 14.3.1.6 2.5 mfd ( composite ) 14.3.1.7 4 mfd ( only supply ) 14.3.1.8 4 mfd ( only labour ) 14.3.1.9 4 mfd ( composite ) 14.3.1.10 5 / 6 mfd ( only supply ) 14.3.1.11 5 / 6 mfd ( only labour ) 14.3.1.12 5 / 6 mfd ( composite ) 14.3.1.13 10 / 15 mfd ( only supply ) 14.3.1.14 10 / 15 mfd ( only labour ) 14.3.1.15 10 / 15 mfd ( composite ) 14.3.1.16 20 mfd ( only supply ) 14.3.1.17 20 mfd ( only labour ) 14.3.1.18 20 mfd ( composite ) 14.3.1.19 33 mfd ( only supply ) 14.3.1.20 33 mfd ( only labour ) 14.3.1.21 33 mfd ( composite ) 14.3.1.22 40 mfd ( only supply ) 14.3.1.23 40 mfd ( only labour ) 14.3.1.24 40 mfd ( composite ) 14.3.1.25 60 mfd ( only supply ) 14.3.1.26 60 mfd ( only labour ) 14.3.1.27 60 mfd ( composite ) 14.3.1.28 80 mfd ( only supply ) 14.3.1.29 80 mfd ( only labour ) 14.3.1.30 80 mfd ( composite ) 14.3.1.31 120 mfd ( only supply ) 14.3.1.32 120 mfd ( only labour ) 14.3.1.33 120 mfd ( composite ) 14.3.1.34 200 mfd ( only supply ) 14.3.1.35 200 mfd ( only labour ) 14.3.1.36 200 mfd ( composite ) 14.4 coils / transformers 14.4.1 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) ( only supply ) 14.4.2 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es. ( only labour ) 14.4.3 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es ( composite ) . 14.4.4 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or any such other specific circuits / appplications. prior approval is required. ( only supply ) 14.4.5 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( only labour ) . 14.4.6 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( composite ) . 15.1 olr / starters / terminal boxes supply & replacement of thermal over load relay for motors or any other such application as decided by e i c, es including lugging, putting insulation tape ets. in case of replacement, removed / replaced parts shall be handed over to e i c, es along with gatepass / challans etc. 15.1.1 up to 7.5 hp ( only supply ) 15.1.2 up to 7.5 hp ( only labour ) 15.1.3 up to 7.5 hp ( composite ) 15.1.4 10 hp to 20 hp ( only supply ) 15.1.5 10 hp to 20 hp ( only labour ) 15.1.6 10 hp to 20 hp ( composite ) 15.1.7 25 hp to 30 hp ( only supply ) 15.1.8 25 hp to 30 hp ( only labour ) 15.1.9 25 hp to 30 hp ( composite ) 15.1.10 35 hp to 40 hp ( only supply ) 15.1.11 35 hp to 40 hp ( only labour ) 15.1.12 35 hp to 40 hp ( composite ) 15.1.13 45 hp to 50 hp ( only supply ) 15.1.14 45 hp to 50 hp ( only labour ) 15.1.15 45 hp to 50 hp ( composite ) 15.1.16 60 hp to 75 hp ( only supply ) 15.1.17 60 hp to 75 hp ( only labour ) 15.1.18 60 hp to 75 hp ( composite ) 15.2 supply, installation, testing & commissioning of dol starters, of reputed make make as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic. in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.2.1 up to 2 hp / 1.5 kw single phase. ( only supply ) 15.2.2 up to 2 hp / 1.5 kw single phase. ( only labour ) 15.2.3 up to 2 hp / 1.5 kw single phase. ( composite ) 15.2.4 up to 7.5 hp / 5.5 kw 3phase. ( only supply ) 15.2.5 up to 7.5 hp / 5.5 kw 3phase. ( only labour ) 15.2.6 up to 7.5 hp / 5.5 kw 3phase. ( composite ) 15.2.7 up to 10 hp ( only supply ) 15.2.8 up to 10 hp ( only labour ) 15.2.9 up to 10 hp ( composite ) 15.2.10 up to 20 hp, ( only supply ) 15.2.11 up to 20 hp, ( only labour ) 15.2.12 up to 20 hp, ( composite ) 15.2.13 for 30 hp. ( only supply ) 15.2.14 for 30 hp. ( only labour ) 15.2.15 for 30 hp. ( composite ) 15.2.16 for 40 hp. ( only supply ) 15.2.17 for 40 hp. ( only labour ) 15.2.18 for 40 hp. ( composite ) 15.3 supply, installation, testing & commissioning of fully automatic star delta motor starters, as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic.in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.3.1 up to 2 hp ( only supply ) 15.3.2 up to 2 hp ( only labour ) 15.3.3 up to 2 hp ( composite ) 15.3.4 up to 5 hp ( only supply ) 15.3.5 up to 5 hp ( only labour ) 15.3.6 up to 5 hp ( composite ) 15.3.7 up to 10 hp ( only supply ) 15.3.8 up to 10 hp ( only labour ) 15.3.9 up to 10 hp ( composite ) 15.3.10 up to 12.5 hp ( only supply ) 15.3.11 up to 12.5 hp ( only labour ) 15.3.12 up to 12.5 hp ( composite ) 15.3.13 up to 15 hp ( only supply ) 15.3.14 up to 15 hp ( only labour ) 15.3.15 up to 15 hp ( composite ) 15.3.16 up to 20 hp ( only supply ) 15.3.17 up to 20 hp ( only labour ) 15.3.18 up to 20 hp ( composite ) 15.3.19 up to 30 hp ( only supply ) 15.3.20 up to 30 hp ( only labour ) 15.3.21 up to 30 hp ( composite ) 15.3.22 up to 50 hp ( only supply ) 15.3.23 up to 50 hp ( only labour ) 15.3.24 up to 50 hp ( composite ) 15.3.25 up to 75 hp ( only supply ) 15.3.26 up to 75 hp ( only labour ) 15.3.27 up to 75 hp ( composite ) 15.3.28 providing & fixing of motor terminal boxes. up to 1 hp ( only supply ) 15.3.29 up to 1 hp ( only labour ) 15.3.30 up to 1 hp ( composite ) 15.3.31 up to 2 hp ( only supply ) 15.3.32 up to 2 hp ( only labour ) 15.3.33 up to 2 hp ( composite ) 15.3.34 up to 5 hp ( only supply ) 15.3.35 up to 5 hp ( only labour ) 15.3.36 up to 5 hp ( composite ) 15.3.37 up to 10 hp ( only supply ) 15.3.38 up to 10 hp ( only labour ) 15.3.39 up to 10 hp ( composite ) 15.3.40 up to 20 hp ( only supply ) 15.3.41 up to 20 hp ( only labour ) 15.3.42 up to 20 hp ( composite ) 15.3.43 up to 30 hp ( only supply ) 15.3.44 up to 30 hp ( only labour ) 15.3.45 up to 30 hp ( composite ) 15.3.46 up to 50 hp ( only supply ) 15.3.47 up to 50 hp ( only labour ) 15.3.48 up to 50 hp ( composite ) 15.3.49 up to 75 hp ( only supply ) 15.3.50 up to 75 hp ( only labour ) 15.3.51 up to 75 hp ( composite ) 16.1 registers / discharge registers register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 18030. ( only supply ) 16.2 register, kiyosh make, 10 kohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( only labour ) 16.3 register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( composite ) 16.4 discharge resistors for capacitor banks up to 100 kvar ( only supply ) 17.1 supply, installing of electrical consumable items with testing & commissioning of them as specifications & as per direction of engg in charge.in case of replacement / repairs, old materials shall be handed over to e i c, es along with gatepass / challans etc. all replacements are subjected to prior approval of o i c, es for any equivalent make, if make is not mentioned. ( kindly refer make list provided separately ) . it may be noted that minimum balance of these itmes are required to maintain on site for emerrgency use. 17.1.1 40 w fluorescent tube reputed make ( only supply ) 17.1.2 40 w fluorescent tube reputed make ( only labour ) 17.1.3 40 w fluorescent tube reputed make ( composite ) 17.1.4 36 w fluorescent tube reputed make ( only supply ) 17.1.5 36 w fluorescent tube reputed make ( only labour ) 17.1.6 36 w fluorescent tube reputed make ( composite ) 17.1.7 20 w fluorescent tube reputed make ( only supply ) 17.1.8 20 w fluorescent tube reputed make ( only labour ) 17.1.9 20 w fluorescent tube reputed make ( composite ) 17.1.10 18 w fluorescent tube reputed make ( only supply ) 17.1.11 18 w fluorescent tube reputed make ( only labour ) 17.1.12 18 w fluorescent tube reputed make ( composite ) 17.1.13 9 w pl s fluorescent tube reputed make ( only supply ) 17.1.14 9 w pl s fluorescent tube reputed make ( only labour ) 17.1.15 9 w pl s fluorescent tube reputed make ( composite ) 17.1.16 11 w pl s fluorescent tube reputed make ( only supply ) 17.1.17 11 w pl s fluorescent tube reputed make ( only labour ) 17.1.18 11 w pl s fluorescent tube reputed make ( composite ) 17.1.19 75 w comptalux lamp of reputed make ( only supply ) 17.1.20 75 w comptalux lamp of reputed make ( only labour ) 17.1.21 75 w comptalux lamp of reputed make ( composite ) 17.1.22 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only supply ) 17.1.23 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only labour ) 17.1.24 30 w germicidal fluorescent ulitrea violet tube of reputed make ( composite ) 17.1.25 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only supply ) 17.1.26 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only labour ) 17.1.27 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( composite ) 17.1.28 same as item no 17.1.22 but 2 or one and the half feet in length ( only supply ) 17.1.29 same as item no 17.1.22 but 2 or one and the half feet in length ( only labour ) 17.1.30 same as item no 17.1.22 but 2 or one and the half feet in length ( only composite ) 17.1.31 insect killer tube size 2 feet ( only supply ) 17.1.32 insect killer tube size 2 feet ( only labour ) 17.1.33 insect killer tube size 2 feet ( composite ) 17.1.34 insect killer tube size one and the half feet ( only supply ) 17.1.35 insect killer tube size one and the half feet ( only labour ) 17.1.36 insect killer tube size one and the half feet ( cokposite ) 17.1.37 100 w gls clear / milky lamp reputed make ( only supply ) 17.1.38 100 w gls clear / milky lamp reputed make ( only labour ) 17.1.39 100 w gls clear / milky lamp reputed make ( composite ) 17.1.40 200w clear / milky gls lamp ( only supply ) 17.1.41 200w clearmtilky gls lamp ( only labour ) 17.1.42 200w clearmtilky gls lamp ( composite ) 17.1.43 60 w gls clear / milky lamp reputed make ( only supply ) 17.1.44 60 w gls clear / milky lamp reputed make ( only labour ) 17.1.45 60 w gls clear / milky lamp reputed make ( composite ) 17.1.46 40 w clear / milky gls lamp ( only supply ) 17.1.47 40 w clear / miilky gls lamp ( only ) 17.1.48 40 w clear / milky gls lamp ( only supply ) 17.1.49 25 w clear / milky lamp reputed make ( only supply ) 17.1.50 25 w clear / milky lamp reputed make ( only labour ) 17.1.51 25 w clear / milky lamp reputed make ( composite ) 17.1.52 15 w red indication lamp reputed make / or other colour for any other specific application. ( supply ) 17.1.53 15 w red indication lamp reputed make / or other colour for any other specific application. ( labour ) 17.1.54 15 w red indication lamp reputed make / or other colour for any other specific application. ( composite ) 17.1.55 25 w incandescent lamp for exit light ( as per sample ) ( only supply ) 17.1.56 25 w incandescent lamp for exit light ( as per sample ) ( only labour ) 17.1.57 25 w incandescent lamp for exit light ( as per sample ) ( composite ) 17.1.58 8 w / 11w pin type cfl lamp ( only supply ) 17.1.59 8 w / 11w pin type cfl lamp ( only labour ) 17.1.60 8 w / 11w pin type cfl lamp ( composite ) 17.1.61 14 w pin type cfl lamp ( only supply ) 17.1.62 14 w pin type cfl lamp ( only labour ) 17.1.63 14 w pin type cfl lamp ( composite ) 17.1.64 23 / 25 w cfl tube ( only supply ) 17.1.65 23 / 25 w cfl tube ( only labour ) 17.1.66 23 / 25 w cfl tube ( composite ) 17.1.67 14 w plc tube ( only supply ) 17.1.68 14 w plc tube ( only labour ) 17.1.69 14 w plc tube ( composite ) 17.1.70 36 w pll tube light ( only supply ) 17.1.71 36 w pll tube light ( only labour ) 17.1.72 36 w pll tube light ( composite ) 17.1.73 electronic choke for 36 w pll fitting ( only supply ) 17.1.74 electronic choke for 36 w pll fitting ( only labour ) 17.1.75 electronic choke for 36 w pll fitting ( composite ) 17.1.76 40 w choke / ballast reputed make ( only supply ) 17.1.77 40 w choke / ballast reputed make ( only labour ) 17.1.78 40 w choke / ballast reputed make ( composite ) 17.1.79 electronic choke ( 40 w ) ( only supply ) 17.1.80 electronic choke ( 40 w ) ( only labour ) 17.1.81 electronic choke ( 40 w ) ( composite ) 17.1.82 20 w choke / ballast reputed make ( only supply ) 17.1.83 20 w choke / ballast reputed make ( only labour ) 17.1.84 20 w choke / ballast reputed make ( only composite ) 17.1.85 9 w choke / ballast reputed make ( only supply ) 17.1.86 9 w choke / ballast reputed make ( only labour ) 17.1.87 9 w choke / ballast reputed make ( composite ) 17.1.88 11 w choke / ballast reputed make ( only supply ) 17.1.89 11 w choke / ballast reputed make ( only labour ) 17.1.90 11 w choke / ballast reputed make ( composite ) 17.1.91 30 w choke / ballast for germicidal fixture gajjars make ( only supply ) 17.1.92 30 w choke / ballast for germicidal fixture gajjars make ( only labour ) 17.1.93 30 w choke / ballast for germicidal fixture gajjars make ( composite ) 17.1.94 fixing / replacing of side holders ( 1 no. ) ( only supply ) 17.1.95 fixing / replacing of side holders ( 1 no. ) ( only labour ) 17.1.96 fixing / replacing of side holders ( 1 no. ) ( composite ) 17.1.97 starter for fluorescent 36w tube light ( only supply ) 17.1.98 starter for fluorescent 36w tube light ( only labour ) 17.1.99 starter for fluorescent 36w tube light ( composite ) 17.1.100 replacing of starter holder for tube light ( only supply ) 17.1.101 replacing of starter holder for tube light ( only labour ) 17.1.102 replacing of starter holder for tube light ( composite ) 17.1.103 replacing of side holder for pl lamp fitting ( only supply ) 17.1.104 replacing of side holder for pl lamp fitting ( only labour ) 17.1.105 replacing of side holder for pl lamp fitting ( composite ) 17.1.106 replacing of halogen tube reputed make 500 w ( only supply ) 17.1.107 replacing of halogen tube reputed make 500 w ( only labour ) 17.1.108 replacing of halogen tube reputed make 500 w ( composite ) 17.1.109 replacing of halogen tube reputed make 1000 w ( only supply ) 17.1.110 replacing of halogen tube reputed make 1000 w ( only labour ) 17.1.111 replacing of halogen tube reputed make 1000 w ( composite ) 17.1.112 15 w ( pigmy lamp ) ( only supply ) 17.1.113 15 w ( pigmy lamp ) ( only labour ) 17.1.114 15 w ( pigmy lamp ) ( composite ) 17.1.115 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only supply ) 17.1.116 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only labour ) 17.1.117 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( composite ) 17.1.118 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only supply ) 17.1.119 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only labour ) 17.1.120 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( composite ) 17.1.121 18 w reputed make choke suitable for 18 w plc tubes ( only supply ) 17.1.122 18 w reputed make choke suitable for 18 w plc tubes ( only labour ) 17.1.123 18 w reputed make choke suitable for 18 w plc tubes ( composite ) 17.1.124 decorative general type table / wall / reading lamp ( plc / cfl / incandescent lamp compatible etc ) ( only supply ) 17.1.125 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only supply ) 17.1.126 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only labour ) 17.1.127 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( composite ) 17.1.128 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only supply ) 17.1.129 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only labour ) 17.1.130 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( composite ) 17.1.131 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only supply ) 17.1.132 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only labour ) 17.1.133 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( composite ) 17.1.134 fixing / replacement of 18 / 20w electronic choke ( only supply ) 17.1.135 fixing / replacement of 18 / 20w electronic choke ( only labour ) 17.1.136 fixing / replacement of 18 / 20w electronic choke ( composite ) 17.1.137 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only supply ) 17.1.138 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only labour ) 17.1.139 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( composite ) 17.1.140 fixing / replacement of 30w fluroscent tube ( only supply ) 17.1.141 fixing / replacement of 30w fluroscent tube ( only labour ) 17.1.142 fixing / replacement of 30w fluroscent tube ( composite ) 17.1.143 fixing / replacement of 9 / 11w electronic choke ( only supply ) 17.1.144 fixing / replacement of 9 / 11w electronic choke ( only labour ) 17.1.145 fixing / replacement of 9 / 11w electronic choke ( composite ) 17.1.146 fixing / replacement of 100w comptlux lamp ( only supply ) 17.1.147 fixing / replacement of 100w comptlux lamp ( only labour ) 17.1.148 fixing / replacement of 100w comptlux lamp ( composite ) 17.1.149 30w tube light 3feet ( only supply ) 17.1.150 30w tube light 3feet ( only labour ) 17.1.151 30w tube light 3feet ( composite ) 17.2 led lamps pin type / thread type 17.2.1 fixing / replacement of 2 / 3w led lamp ( only supply ) 17.2.2 fixing / replacement of 2 / 3w led lamp ( only labour ) 17.2.3 fixing / replacement of 2 / 3w led lamp ( composite ) 17.2.4 fixing / replacement of 5 / 7 / 9w led lamp ( only supply ) 17.2.5 fixing / replacement of 5 / 7 / 9w led lamp ( only labour ) 17.2.6 fixing / replacement of 5 / 7 / 9w led lamp ( composite ) 17.2.7 fixing / replacement of 12w led lamp ( only supply ) 17.2.8 fixing / replacement of 12w led lamp ( only labour ) 17.2.9 fixing / replacement of 12w led lamp ( composite ) 17.2.10 fixing / replacement of 15w led lamp ( only supply ) 17.2.11 fixing / replacement of 15w led lamp ( only labour ) 17.2.12 fixing / replacement of 15w led lamp ( composite ) 17.2.13 fixing / replacement of 18w led lamp ( only supply ) 17.2.14 fixing / replacement of 18w led lamp ( only labour ) 17.2.15 fixing / replacement of 18w led lamp ( composite ) 17.2.16 fixing / replacement of 8w 2 long led tube ( only supply ) 17.2.17 fixing / replacement of 8w 2 long led tube ( only labour ) 17.2.18 fixing / replacement of 8w 2 long led tube ( composite ) 17.2.19 fixing / replacement of 18w led pll lamp ( only supply ) 17.2.20 fixing / replacement of 18w led pll lamp ( only labour ) 17.2.21 fixing / replacement of 18w led pll lamp ( composite ) 17.2.22 fixing / replacement of 30w led lamp ( only supply ) 17.2.23 fixing / replacement of 30w led lamp ( only labour ) 17.2.24 fixing / replacement of 30w led lamp ( composite ) 17.2.25 fixing / replacement of 35w led lamp ( only supply ) 17.2.26 fixing / replacement of 35w led lamp ( only labour ) 17.2.27 fixing / replacement of 35w led lamp ( composite ) 17.3 led driver 17.3.1 fixing / replacement of 3 / 5w led driver ( only supply ) 17.3.2 ffixing / replacement 3 / 5w led driver ( only labour ) 17.3.3 fixing / replacement of 3 / 5w led driver ( composite ) 17.3.4 fixing / replacement of 9w led driver ( only supply ) 17.3.5 ffixing / replacement 9w led driver ( only labour ) 17.3.6 fixing / replacement of 9w led driver ( composite ) 17.3.7 fixing / replacement of 12 / 15w led driver ( only supply ) 17.3.8 ffixing / replacement 12 / 15w led driver ( only labour ) 17.3.9 fixing / replacement of 12 / 15w led driver ( composite ) 17.3.10 fixing / replacement of 18w led driver ( only supply ) 17.3.11 ffixing / replacement 18w led driver ( only labour ) 17.3.12 fixing / replacement of 18w led driver ( composite ) 17.3.13 fixing / replacement of 24w led driver ( only supply ) 17.3.14 ffixing / replacement 24w led driver ( only labour ) 17.3.15 fixing / replacement of 24w led driver ( composite ) 17.3.16 fixing / replacement of 30w led driver ( only supply ) 17.3.17 ffixing / replacement 30w led driver ( only labour ) 17.3.18 fixing / replacement of 30w led driver ( composite ) 17.3.19 fixing / replacement of 36w led driver ( only supply ) 17.3.20 ffixing / replacement 36w led driver ( only labour ) 17.3.21 fixing / replacement of 36w led driver ( composite ) 18.1 gyesers / heaters supply, installation, testing & commissining of various types of water gyesers, heaters, heating coils, hot plates, strip heaters or any similar application heating equipment as per the required specifications as per instructions & as directed by e i c, es. in case of replacement / repairs, old items are to be handed over to e i c, es along with gatepass / challans etc. 18.1.1 25 litre capacity , hospital use water heater ( only supply ) 18.1.2 25 litre capacity , hospital use water heater ( only labour ) 18.1.3 25 litre capacity , hospital use water heater ( composite ) 18.1.4 reputed make 6 litre capacity , hospital use water heater ( only supply ) 18.1.5 reputed make 6 litre capacity , hospital use water heater ( only labour ) 18.1.6 reputed make 6 litre capacity , hospital use water heater ( composite ) 18.1.7 reputed make 1 litre capacity water geyser ( only supply ) 18.1.8 reputed make 1 litre capacity water geyser ( only labour ) 18.1.9 reputed make 1 litre capacity water geyser ( composite ) 18.1.10 reputed make 2 litre capacity water geyser ( only supply ) 18.1.11 reputed make 2 litre capacity water geyser ( only labour ) 18.1.12 reputed make 2 litre capacity water geyser ( composite ) 18.1.13 reputed make 3 litre capacity water geyser ( only supply ) 18.1.14 reputed make 3 litre capacity water geyser ( only labour ) 18.1.15 reputed make 3 litre capacity water geyser ( composite ) 18.2 thermostats and heating coils. 18.2.1 thermostat of good quality for all types of gysers ( only supply ) 18.2.2 thermostat of good quality for all types of gysers ( only labour ) 18.2.3 thermostat of good quality for all types of gysers ( composite ) 18.2.4 thermostats0 300 oc for oven ( only supply ) 18.2.5 thermostats0 300 oc for oven ( only labour ) 18.2.6 thermostats0 300 oc for oven ( composite ) 18.2.7 supply / replacement of coil for hot plate ( only supply ) 18.2.8 supply / replacement of coil for hot plate ( only supply ) 18.2.9 supply / replacement of coil for hot plate ( only supply ) 18.2.10 supply / replacement of coil for iron ( only supply ) 18.2.11 supply / replacement of coil for iron ( only labour ) 18.2.12 supply / replacement of coil for iron ( composite ) 18.2.13 fixing / replacement of coil / tube type heaters for geysers1000 w ( only supply ) 18.2.14 fixing / replacement of coil / tube type heaters for geysers1000 w ( only labour ) 18.2.15 fixing / replacement of coil / tube type heaters for geysers1000 w ( composite ) 18.2.16 fixing / replacement of coil / tube type heaters for geysers1500 w ( only supply ) 18.2.17 fixing / replacement of coil / tube type heaters for geysers1500 w ( only labour ) 18.2.18 fixing / replacement of coil / tube type heaters for geysers1500 w ( composite ) 18.2.19 fixing / replacement of coil / tube type heaters for geysers2000 w ( only supply ) 18.2.20 fixing / replacement of coil / tube type heaters for geysers2000 w ( only labour ) 18.2.21 fixing / replacement of coil / tube type heaters for geysers2000 w ( composite ) 18.2.22 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only supply ) 18.2.23 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only labour ) 18.2.24 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( composite ) 18.2.25 3000 w ( idli / chapati maker etc ) ( only supply ) 18.2.26 3000 w ( idli / chapati maker etc ) ( only labour ) 18.2.27 3000 w ( idli / chapati maker etc ) ( composite ) 18.2.28 500 w coil heater ( only supply ) 18.2.29 500 w coil heater ( only labour ) 18.2.30 500 w coil heater ( composite ) 18.2.31 replacement of kettle heaters ( only supply ) 18.2.32 replacement of kettle heaters ( only labour ) 18.2.33 replacement of kettle heaters ( composite ) 18.2.34 replacement of over load relay for gysers / hot plates and other similar equipments. ( only supply ) 18.2.35 replacement of over load relay for gysers / hot plates and other similar equipments. ( only labour ) 18.2.36 replacement of over load relay for gysers / hot plates and other similar equipments. ( composite ) 18.2.37 replacement of sealer coil ( only supply ) 18.2.38 replacement of sealer coil ( only labour ) 18.2.39 replacement of sealer coil ( composite ) 18.3 strip heaters. 18.3.1 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only supply ) 18.3.2 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only labour ) 18.3.3 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( composite ) 18.3.4 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only supply ) 18.3.5 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only labour ) 18.3.6 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( composite ) 18.3.7 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.8 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.9 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.10 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.11 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.12 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.13 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.14 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.15 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( composite ) 19.1.a mv cable work supply. installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round / flat wire armoured copper / al conductor power cables isi mark reputed make fixed on wall / column / ceiling or in shaft / existing trench on 6 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.1.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.1.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.1.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.1.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.1.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.1.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.1.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.1.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.1.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.1.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.1.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.1.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.1.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.1.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.1.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.1.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.1.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.1.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.1.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.1.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.1.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.2 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.2.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.2.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.2.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.2.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.2.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.2.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.2.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.2.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.2.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.2.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.2.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.2.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.2.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.2.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.2.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.2.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.2.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.2.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.2.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.2.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.2.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.3 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.3.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.3.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.3.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.3.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.3.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.3.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.3.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.3.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.3.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.3.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.3.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.3.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.3.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.3.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.3.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.3.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.3.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.3.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.3.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.3.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.3.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.4 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured copper / aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench on 5 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.4.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.4.2. 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.4.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.4.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.4.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.4.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.4.7 4 x 4 sq. mm copper conductor ( only supply ) 19.4.8 4 x 4 sq. mm copper conductor ( only labour ) 19.4.9 4 x 4 sq. mm copper conductor ( composite ) 19.4.10 4 x 6 sq. mm copper conductor ( only supply ) 19.4.11 4 x 6 sq. mm copper conductor ( only labour ) 19.4.12 4 x 6 sq. mm copper conductor ( composite ) 19.4.13 4 x 10 sq. mm copper conductor ( only supply ) 19.4.14 4 x 10 sq. mm copper conductor ( only labour ) 19.4.15 4 x 10 sq. mm copper conductor ( composite ) 19.4.16 4 x 16 sq. mm copper conductor ( only supply ) 19.4.17 4 x 16 sq. mm copper conductor ( only labour ) 19.4.18 4 x 16 sq. mm copper conductor ( composite ) 19.4.19 4 x 25 sq. mm copper conductor ( only supply ) 19.4.20 4 x 25 sq. mm copper conductor ( only labour ) 19.4.21 4 x 25 sq. mm copper conductor ( composite ) 19.4.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.4.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.4.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.4.25 4 x 10 sq. mm al conductor ( only supply ) 19.4.26 4 x 10 sq. mm al conductor ( only labour ) 19.4.27 4 x 10 sq. mm al conductor ( composite ) 19.4.28 4 x 16 sq. mm al conductor ( only supply ) 19.4.29 4 x 16 sq. mm al conductor ( only labour ) 19.4.30 4 x 16 sq. mm al conductor ( composite ) 19.4.31 4 x 25 sq. mm al conductor ( only supply ) 19.4.32 4 x 25 sq. mm al conductor ( only labour ) 19.4.33 4 x 25 sq. mm al conductor ( composite ) 19.4.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.4.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.4.36 3.5 x 25 sq. mm al conducto ( composite ) 19.4.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.4.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.4.39 3.5 x 35 sq. mm al conductor ( composite ) 19.4.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.4.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.4.42 3.5 x 50 sq. mm al conducto ( composite ) 19.4.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.4.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.4.45 3.5 x 70 sq. mm al conductor ( composite ) 19.4.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.4.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.4.48 3.5 x 95 sq. mm al conductor ( composite ) 19.5 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.5.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.5.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.5.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.5.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.5.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.5.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.5.7 4 x 4 sq. mm copper conductor ( only supply ) 19.5.8 4 x 4 sq. mm copper conductor ( only labour ) 19.5.9 4 x 4 sq. mm copper conductor ( composite ) 19.5.10 4 x 6 sq. mm copper conductor ( only supply ) 19.5.11 4 x 6 sq. mm copper conductor ( only labour ) 19.5.12 4 x 6 sq. mm copper conductor ( composite ) 19.5.13 4 x 10 sq. mm copper conductor ( only supply ) 19.5.14 4 x 10 sq. mm copper conductor ( only labour ) 19.5.15 4 x 10 sq. mm copper conductor ( composite ) 19.5.16 4 x 16 sq. mm copper conductor ( only supply ) 19.5.17 4 x 16 sq. mm copper conductor ( only labour ) 19.5.18 4 x 16 sq. mm copper conductor ( composite ) 19.5.19 4 x 25 sq. mm copper conductor ( only supply ) 19.5.20 4 x 25 sq. mm copper conductor ( only labour ) 19.5.21 4 x 25 sq. mm copper conductor ( composite ) 19.5.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.5.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.5.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.5.25 4 x 10 sq. mm al conductor ( only supply ) 19.5.26 4 x 10 sq. mm al conductor ( only labour ) 19.5.27 4 x 10 sq. mm al conductor ( composite ) 19.5.28 4 x 16 sq. mm al conductor ( only supply ) 19.5.29 4 x 16 sq. mm al conductor ( only labour ) 19.5.30 4 x 16 sq. mm al conductor ( composite ) 19.5.31 4 x 25 sq. mm al conductor ( only supply ) 19.5.32 4 x 25 sq. mm al conductor ( only labour ) 19.5.33 4 x 25 sq. mm al conductor ( composite ) 19.5.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.5.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.5.36 3.5 x 25 sq. mm al conducto ( composite ) 19.5.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.5.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.5.39 3.5 x 35 sq. mm al conductor ( composite ) 19.5.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.5.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.5.42 3.5 x 50 sq. mm al conducto ( composite ) 19.5.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.5.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.5.45 3.5 x 70 sq. mm al conductor ( composite ) 19.5.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.5.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.5.48 3.5 x 95 sq. mm al conductor ( composite ) 19.6 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.6.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.6.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.6.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.6.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.6.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.6.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.6.7 4 x 4 sq. mm copper conductor ( only supply ) 19.6.8 4 x 4 sq. mm copper conductor ( only labour ) 19.6.9 4 x 4 sq. mm copper conductor ( composite ) 19.6.10 4 x 6 sq. mm copper conductor ( only supply ) 19.6.11 4 x 6 sq. mm copper conductor ( only labour ) 19.6.12 4 x 6 sq. mm copper conductor ( composite ) 19.6.13 4 x 10 sq. mm copper conductor ( only supply ) 19.6.14 4 x 10 sq. mm copper conductor ( only labour ) 19.6.15 4 x 10 sq. mm copper conductor ( composite ) 19.6.16 4 x 16 sq. mm copper conductor ( only supply ) 19.6.17 4 x 16 sq. mm copper conductor ( only labour ) 19.6.18 4 x 16 sq. mm copper conductor ( composite ) 19.6.19 4 x 25 sq. mm copper conductor ( only supply ) 19.6.20 4 x 25 sq. mm copper conductor ( only labour ) 19.6.21 4 x 25 sq. mm copper conductor ( composite ) 19.6.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.6.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.6.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.6.25 4 x 10 sq. mm al conductor ( only supply ) 19.6.26 4 x 10 sq. mm al conductor ( only labour ) 19.6.27 4 x 10 sq. mm al conductor ( composite ) 19.6.28 4 x 16 sq. mm al conductor ( only supply ) 19.6.29 4 x 16 sq. mm al conductor ( only labour ) 19.6.30 4 x 16 sq. mm al conductor ( composite ) 19.6.31 4 x 25 sq. mm al conductor ( only supply ) 19.6.32 4 x 25 sq. mm al conductor ( only labour ) 19.6.33 4 x 25 sq. mm al conductor ( composite ) 19.6.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.6.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.6.36 3.5 x 25 sq. mm al conducto ( composite ) 19.6.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.6.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.6.39 3.5 x 35 sq. mm al conductor ( composite ) 19.6.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.6.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.6.42 3.5 x 50 sq. mm al conducto ( composite ) 19.6.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.6.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.6.45 3.5 x 70 sq. mm al conductor ( composite ) 19.6.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.6.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.6.48 3.5 x 95 sq. mm al conductor ( composite ) 19.7 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous 8 swg copper bare wire for earthing & end termination. 19.7.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.7.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.7.3 3.5 x 120 sq. mm al conductor ( composite ) 19.7.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.7.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.7.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.7.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.7.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.7.9 3.5 x 185 sq. mm al conductor ( composite ) 19.7.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.7.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.7.12 3.5 x 240 sq. mm al conductor ( composite ) 19.7.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.7.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.7.15 3.5 x 300 sq. mm al conductor ( composite ) 19.7.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.7.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.7.18 3.5 x 400 sq. mm al conductor ( composite ) 19.8 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.8.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.8.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.8.3 3.5 x 120 sq. mm al conductor ( composite ) 19.8.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.8.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.8.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.8.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.8.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.8.9 3.5 x 185 sq. mm al conductor ( composite ) 19.8.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.8.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.8.12 3.5 x 240 sq. mm al conductor ( composite ) 19.8.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.8.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.8.15 3.5 x 300 sq. mm al conductor ( composite ) 19.8.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.8.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.8.18 3.5 x 400 sq. mm al conductor ( composite ) 19.9 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.9.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.9.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.9.3 3.5 x 120 sq. mm al conductor ( composite ) 19.9.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.9.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.9.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.9.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.9.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.9.9 3.5 x 185 sq. mm al conductor ( composite ) 19.9.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.9.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.9.12 3.5 x 240 sq. mm al conductor ( composite ) 19.9.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.9.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.9.15 3.5 x 300 sq. mm al conductor ( composite ) 19.9.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.9.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.9.18 3.5 x 400 sq. mm al conductor ( composite ) 19.10.a supply, installation, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark make fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous copper strip / wire earthing as required & as directed by o i c, es. 19.10.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.10.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.10.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.10.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.10.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.10.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.11 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark pvc insulated isi mark armored, bright annealed copper conductor cable below earth 1200 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.11.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.11.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.11.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.11.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.11.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.11.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.12 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11kv grade cable, isi mark , laying in ground at 1200 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.12.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.12.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.12.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.12.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.12.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.12.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 20.1 gi pipes / foot valvessupply, installation gi pipes class b type with all fixing arrangement such as couplings, bends etc on any kind of surface or below ground as per the instruction of e i c. 20.1.1 gi pipe 25 mm ( only supply ) 20.1.2 gi pipe 25 mm ( only labour ) 20.1.3 gi pipe 25 mm ( composite ) 20.1.4 gi pipe 32 mm ( only supply ) 20.1.5 gi pipe 32 mm ( only labour ) 20.1.6 gi pipe 32 mm ( composite ) 20.1.7 gi pipe 38 mm ( only supply ) 20.1.8 gi pipe 38 mm ( only labour ) 20.1.9 gi pipe 38 mm ( composite ) 20.1.10 gi pipe 50 mm ( only supply ) 20.1.11 gi pipe 50 mm ( only labour ) 20.1.12 gi pipe 50 mm ( composite ) 20.2 supply / replacement of foot valve of various sizes with all necessary arrangement for making it properly function, all as per the instructions and as per directions of e i c, es 20.2.1 threefourth inch ( only supply ) 20.2.2 threefourth inch ( only labour ) 20.2.3 threefourth inch ( composite ) 20.2.4 1inch ( only supply ) 20.2.5 1inch ( only labour ) 20.2.6 1inch ( composite ) 20.2.7 2inch ( only supply ) 20.2.8 2inch ( only labour ) 20.2.9 2inch ( composite ) 20.2.10 3inch ( only supply ) 20.2.11 3inch ( only labour ) 20.2.12 3inch ( composite ) 20.3 exavation / hume pipes / dwc pipes 20.3.1 supply, installation of oval / circular shape gi casted cable marker complete with 38 m dia gi support 1: 3: 6 pcc base, concreting / gi nut bolts, engraved as ht / mv / lt / tel.cables etc. as per instruction of eic. all as directed by o i c with prior approval. ( composite ) 20.3.2 exavation of all kind of soil as per required 900 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, reinstatement, after work completion, if necessary disposal of excess earth within the radius of 500 mtrs etc, stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.3 exavation of hard rock as per reuired 900 / 1200 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, if necessary disposal of excess earth within the radius of 500 mtrs etc. stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 21 supply, laying, testing & commissioning of rg 11 television cable through casing capping / pvc conduits / gi ms pipes on any kind of surface / below ground through dwc pipe through out the campus as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es. 21.1 rg 11 cable ( only supply ) 21.2 rg 11 cable supply and laying pvc casing capping / conduit pipe ( composite ) 21.3 rg 11 cable laying through dwc hdpe pipe pipe ( composite ) 21.10.a supply of rg 59 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.11 laying of rg 59 television cable through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.12 supply, laying, testing & commissioning of rg 59 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 21.13 supply of rg 6 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.14 laying of rg 6 television cable through provided casing capping / pvc conduits / gi ms pipes any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.15 supply, laying, testing & commissioning of rg 6 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 22 corrogated water pipe 22.1 supply / replacement of corrogated water pipe with prior approval will all accessories and fixing arrangement, all as per instructions and as directed by e i c, es. 22.1.1 threefourth inch ( only supply ) 22.1.2 threefourth inch ( only labour ) 22.1.3 threefourth inch ( composite ) 22.1.4 1inch ( only supply ) 22.1.5 1inch ( only labour ) 22.1.6 1inch ( composite ) 22.1.7 2inch ( only supply ) 22.1.8 2inch ( only labour ) 22.1.9 2inch ( composite ) 22.1.10 3inch ( only supply ) 22.1.11 3inch ( only labour ) 22.1.12 3inch ( composite ) 23.1 telephone cable / joint kits / tag blockssupply, installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed cable fixed on slab / wall / coloum / existing trench etc. on 6 mm thick gi spacer / ms flat support with wooden screws with 18 swg gi saddle all fixing accessories & jointing of the both the ends of cable s with all jointing materials like cable glands, cable end box if required, ferrule lugs, ferrule numbers, wire dressing clamps / buttons etc. complete all as per instruction of e i c. 23.1.1 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only supply ) 23.1.2 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only labour ) 23.1.3 as per item no 23.1 but for 0.5 mm dia 10 pair. ( composite ) 23.1.4 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only supply ) 23.1.5 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only labour ) 23.1.6 as per item no 23.1 but for 0.5 mm dia 20 pair. ( composite ) 23.1.7 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only supply ) 23.1.8 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only labour ) 23.1.9 as per item no 23.1 but for 0.5 mm dia 50 pair. ( composite ) 23.1.10 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only supply ) 23.1.11 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only labour ) 23.1.12 as per item no 23.1 but for 0.5 mm dia 100 pair. ( composite ) 23.1.13 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only supply ) 23.1.14 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only labour ) 23.1.15 as per item no 23.1 but for 0.5 mm dia 200 pair. ( composite ) 23.2 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of soil / sand bedding laying of backed bricks as per is on side & top, back filling dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.2.1 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only supply ) 23.2.2 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only labour ) 23.2.3 as per item no 23.2 but for 0.5 mm dia 10 pair. ( composite ) 23.2.4 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only supply ) 23.2.5 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only labour ) 23.2.6 as per item no 23.2 but for 0.5 mm dia 20 pair. ( composite ) 23.2.7 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only supply ) 23.2.8 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only labour ) 23.2.9 as per item no 23.2 but for 0.5 mm dia 50 pair. ( composite ) 23.2.10 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only supply ) 23.2.11 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only labour ) 23.2.12 as per item no 23.2 but for 0.5 mm dia 100 pair. ( composite ) 23.2.13 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only supply ) 23.2.14 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only labour ) 23.2.15 as per item no 23.2 but for 0.5 mm dia 200 pair. ( composite ) 23.3 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of laying through suitable dwc hdpe pipe, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.3.1 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only supply ) 23.3.2 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only labour ) 23.3.3 as per item no 23.3 but for 0.5 mm dia 10 pair. ( composite ) 23.3.4 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only supply ) 23.3.5 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only labour ) 23.3.6 as per item no 23.3 but for 0.5 mm dia 20 pair. ( composite ) 23.3.7 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only supply ) 23.3.8 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only labour ) 23.3.9 as per item no 23.3 but for 0.5 mm dia 50 pair. ( composite ) 23.3.10 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only supply ) 23.3.11 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only labour ) 23.3.12 as per item no 23.3 but for 0.5 mm dia 100 pair. ( composite ) 23.3.13 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only supply ) 23.3.14 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only labour ) 23.3.15 as per item no 23.3 but for 0.5 mm dia 200 pair. ( composite ) 23.4 supply, installation, testing & commissioning of straight through telephone jointing kits preferably of raychem make or alternately m seal of mahindra make for jelly filled armoured telephone cable including dressing, cleaning of the jelly, supply of all jointing materials, etc. complete as required and as per relevant specifications and as directed by e i c. 23.4.1 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only supply ) 23.4.2 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only labour ) 23.4.3 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( composite ) 23.4.4 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only supply ) 23.4.5 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only labour ) 23.4.6 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( composite ) 23.4.7 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only supply ) 23.4.8 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only labour ) 23.4.9 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( composite ) 23.4.10 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only supply ) 23.4.11 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only labour ) 23.4.12 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( composite ) 23.4.13 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only supply ) 23.4.14 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only labour ) 23.4.15 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( composite ) 23.5 supply, installation, testing & commissioning of crone connector telephone tag block box, fabricated out of 14 swg ms crca sheet mounted on ms frame of size 40 x 40 x 5 mm & grouted on the wall / fixed on the coloum free standing type with anchor fastener with front openable hinged doors cam type locking arrangements, neoprene gasket for joints painting with seven tank metal treatment process & with two coats of red oxide primer & two coats of approved shade enamel paint, norm plate etc. as per the instruction of eic. 23.5.1 2 x 10 ways telephone tag block. ( only supply ) 23.5.2 2 x 10 ways telephone tag block. ( only labour ) 23.5.3 2 x 10 ways telephone tag block. ( composite ) 23.5.4 2 x 20 ways telephone tag block. ( only supply ) 23.5.5 2 x 20 ways telephone tag block. ( only labour ) 23.5.6 2 x 20 ways telephone tag block. ( composite ) 23.5.7 2 x 50 ways telephone tag block. ( only supply ) 23.5.8 2 x 50 ways telephone tag block. ( only labour ) 23.5.9 2 x 50 ways telephone tag block. ( composite ) 23.5.10 2 x 60 ways telephone tag block. ( only supply ) 23.5.11 2 x 60 ways telephone tag block. ( only labour ) 23.5.12 2 x 60 ways telephone tag block. ( composite ) 23.5.13 2 x 100 ways telephone tag block. ( only supply ) 23.5.14 2 x 100 ways telephone tag block. ( only labour ) 23.5.15 2 x 100 ways telephone tag block. ( composite ) 23.5.16 2 x 200 ways telephone tag block. ( only supply ) 23.5.17 2 x 200 ways telephone tag block. ( only labour ) 23.5.18 2 x 200 ways telephone tag block. ( composite ) 23.5.19 2 x 240 ways telephone tag block. ( only supply ) 23.5.20 2 x 240 ways telephone tag block. ( only labour ) 23.5.21 2 x 240 ways telephone tag block. ( composite ) 23.5.22 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only supply ) 23.5.23 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only labour ) 23.5.24 supply & fixing of 10 way crone connectors of good quality with prior approval. ( composite ) 24.1 cable glands and lugssupplying & erecting heavy duty flange type brass cable glands for end jointing of various sizes for pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected, with gland double earthing, work completed in all respect all as per instructions and as directed by e i c, es 24.1.1 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only supply ) 24.1.2 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only labour ) 24.1.3 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( composite ) 24.1.4 as per item no 24.1 but for but 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm as per item no 24.1 but for ( only supply ) 24.1.5 as per item no 24.1 but for 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( only labour ) 24.1.6 same as abovebut 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( composite ) 24.1.7 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only supply ) 24.1.8 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only labour ) 24.1.9 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( composite ) 24.1.10 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only supply ) 24.1.11 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only labour ) 24.1.12 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( composite ) 24.1.13 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only supply ) 24.1.14 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only labour ) 24.1.15 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( composite ) 24.1.16 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only supply ) 24.1.17 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only labour ) 24.1.18 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( composite ) 24.1.19 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only supply ) 24.1.20 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only labour ) 24.1.21 as per item no 24.1 but for 3.5 x 95 sq.mmsame as above ( composite ) 24.1.22 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( only supply ) 24.1.23 as per item no 24.1 but for 3.5 x 120 sq.mmsame as above ( only labour ) 24.1.24 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( composite ) 24.1.25 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only supply ) 24.1.26 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only labour ) 24.1.27 as per item no 24.1 but for 3.5 x 150 sq.mmsame as above ( composite ) 24.1.28 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only supply ) 24.1.29 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only labour ) 24.1.30 as per item no 24.1 but for 3.5 x 185 sq.mm same as above ( compsite ) 24.1.31 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only supply ) 24.1.32 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only labour ) 24.1.33 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( composite ) 24.1.34 as per item no 24.1 but for 3.5 x 300 sq.mmsame as above ( only supply ) 24.1.35 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( only labour ) 24.1.36 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( composite ) 24.1.37 as per item no 24.1 but for 3.5 x 400 sq.mmsame as above ( only supply ) 24.1.38 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( only labour ) 24.1.39 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( composite ) 24.2 lugs supplying & erecting crimping type copper lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.2.1 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only supply ) 24.2.2 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only labour ) 24.2.3 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( composite ) 24.2.4 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only supply ) 24.2.5 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only labour ) 24.2.6 as per item no 24.2 but for 25 sq. mm as per item no 24.2 but for ( composite ) 24.2.7 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only supply ) 24.2.8 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only labour ) 24.2.9 as per item no 24.2 but for 35 sq. mmas per item no 24.2 but for ( composite ) 24.2.10 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only supply ) 24.2.11 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only labour ) 24.2.12 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( composite ) 24.2.13 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( only supply ) 24.2.14 as per item no 24.2 but for 70 sq. mmas per item no 24.2 but for ( only labour ) 24.2.15 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( composite ) 24.2.16 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( only supply ) 24.2.17 as per item no 24.2 but for 95 sq. mm as per item no 24.2 but for ( only labour ) 24.2.18 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( composite ) 24.2.19 as per item no 24.2 but for 120 sq. mmas per item no 24.2 but for ( only supply ) 24.2.20 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( only labour ) 24.2.21 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( composite ) 24.2.22 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only supply ) 24.2.23 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only labour ) 24.2.24 as per item no 24.2 but for 150 sq. mm as per item no 24.2 but for ( composite ) 24.2.25 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( only supply ) 24.2.26 as per item no 24.2 but for 185 sq. mm as per item no 24.2 but for ( only labour ) 24.2.27 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( composite ) 24.2.28 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( only supply ) 24.2.29 as per item no 24.2 but for 240 sq. mm as per item no 24.2 but for ( only labour ) 24.2.30 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( composite ) 24.2.31 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( only supply ) 24.2.32 as per item no 24.2 but for 300 sq. mm as per item no 24.2 but for ( only labour ) 24.2.33 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( composite ) 24.2.34 as per item no 24.2 but for 400 sq. mmas per item no 24.2 but for ( only supply ) 24.2.35 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( only labour ) 24.2.36 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( composite ) 24.3 supplying & erecting crimping type aluminium lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.3.1 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only supply ) 24.3.2 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only labour ) 24.3.3 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( composite ) 24.3.4 as per item no 24.3 but for 25 sq. mm as per item no 24.3 but for ( only supply ) 25.1 flexible cable / borewell cablesupply & fixing of white / black colour pvc insulation of various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc. all as directed by o i c, es. 25.1.1 3 x 1.5 sq. mm flexible cable ( only supply ) 25.1.2 3 x 1.5 sq. mm flexible cable ( only labour ) 25.1.3 3 x 1.5 sq. mm flexible cable ( composite ) 25.1.4 3 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.5 3 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.6 3 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.7 3 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.8 3 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.9 3 x 4 sq. mm pvc flexible cable ( composite ) ) 25.1.10 2 x 1.5 sq. mm pvc flexible cable ( only supply ) 25.1.11 2 x 1.5 sq. mm pvc flexible cable ( only labour ) 25.1.12 2 x 1.5 sq. mm pvc flexible cable ( composite ) 25.1.13 2 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.14 2 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.15 2 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.16 4 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.17 4 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.18 4 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.19 4 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.20 4 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.21 4 x 4 sq. mm pvc flexible cable ( composite ) 25.2 supply & fixing of pvc insulated various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc for bore well connection, all as directed by o i c, es. 25.2.1 3c x 1.5 sq. mm cable ( only supply ) 25.2.2 3c x 1.5 sq. mm cable ( only labour ) 25.2.3 3c x 1.5 sq. mm cable ( composite ) 25.2.4 3c x 2.5 sq. mm cable ( only supply ) 25.2.5 3c x 2.5 sq. mm cable ( only labour ) 25.2.6 3c x 2.5 sq. mm cable ( composite ) 25.2.7 3c x 4 sq. mm cable ( only supply ) 25.2.8 3c x 4 sq. mm cable ( only labour ) 25.2.9 3c x 4 sq. mm cable ( composite ) 26 water level controller 26.1 supply, installation, testing & commissioning of water level controller for maintaining of desired level of water in water tank etc, having all sensing mechanium in place, as complete unit, with all other necessary arrangement of proper finctioning etc, all as per instruction and as per derection of e i c, es 26.1.1 automatic water level controller with sensor ( only supply ) 26.1.2 automatic water level controller with sensor ( only labour ) 26.1.3 automatic water level controller with sensor ( composite ) 26.1.4 sensor for water level controller ( only supply ) 26.1.5 sensor for water level controller ( only labour ) 26.1.6 sensor for water level controller ( composite ) 26.1.7 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.8 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.9 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.10 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 5.8 / 8.5 liters per sec. for head of 20 / 36 m and 65 mm suction / 50mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.11 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.12 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.13 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.14 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.15 supplying and erecting submercible water pump set suitable for erection on open well of 5 hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 26.1.16 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.17 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.18 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 27.1 earthingsupplying & installation of tinned copper strip / bare copper wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continity test etc & all as directed by engg. in charge. 27.1.1 8 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.2 8 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.3 8 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.4 10 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.5 10 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.6 10 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.7 12 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.8 12 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.9 12 swg tinned copper bare wire ( 1 run ) ( only composite ) 27.1.10 14 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.11 14 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.12 14 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.13 16 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.14 16 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.15 16 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.16 copper strip of size 25 x 3 mm ( 1 run ) ( only supply ) 27.1.17 copper strip of size 25 x 3 mm ( 1 run ) ( only labour ) 27.1.18 copper strip of size 25 x 3 mm ( 1 run ) ( composite ) 27.1.19 copper strip of size 25 x 5 mm ( 1 run ) ( only supply ) 27.1.20 copper strip of size 25 x 5 mm ( 1 run ) ( only labour ) 27.1.21 copper strip of size 25 x 5 mm ( 1 run ) ( composite ) 27.1.22 copper strip of size 50 x 6 mm ( 1 run ) ( only supply ) 27.1.23 copper strip of size 50 x 6 mm ( 1 run ) ( only labour ) 27.1.24 copper strip of size 50 x 6 mm ( 1 run ) ( composite ) 27.2 gi earthing strip supplying & installation of tinned gi strip / bare gi wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continuty test etc & all as directed by engg. in charge. 27.2.1 gi strip size 25 x 3 mm ( 1 run ) ( only supply ) 27.2.2 gi strip size 25 x 3 mm ( 1 run ) ( only labour ) 27.2.3 gi strip size 25 x 3 mm ( 1 run ) ( compsite ) 27.2.4 gi strip size 25 x 5 mm ( 1 run ) ( only supply ) 27.2.5 gi strip size 25 x 5 mm ( 1 run ) ( only labour ) 27.2.6 gi strip size 25 x 5 mm ( 1 run ) ( compsite ) 27.2.7 gi wire 8 swg, ( 1 run ) ( only supply ) 27.2.8 gi wire 8 swg, ( 1 run ) ( only labour ) 27.2.9 gi wire 8 swg, ( 1 run ) ( composite ) 27.3 earting stations / pits 27.3.1 maintenance of earthing pits treated type with charcoal , salt , water as per standard practice. 27.3.2 tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like cole, charcoal, salt, brass nut bolts & washers, watering arrangements, gi pipe ( b class ) , concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. etc. ( 2 nos, of neutral earthing of t / f, 2 nos. for t / f body earthing & 2 nos. for panel earthing ) hot dipped gi earth plate electrode 600 x 600 x 6.3 mm earth station 2.5 mtr below the ground level same as above as per drawing & specifications complete with all required materials like coke / charcoal, salts , brass nut bolts & washers, watering arrangement, gu pipe ( b class ) concrete / brick chamber, heavy duty cast iron cover plate & excavation in ground, refilling & removing of excess earth within a radius of 500 mtr.etc. scope also includes dewatering, shoring, & consolidation etc. ( composite ) 27.4 air terminator / lightening arrestor 27.4.1 air terminator consisting of 75 to 100 mm dia & 6 mm thick tin copper sphere with 5 nos of spikes of 6 mm dia, 100 mm long, 19 mm dia 600 mm long tinned copper rod 150 mm dia 10 mm thickness tinned copper flange, 200 x 200 x 10 mm tinned brass plate gi grouting bolts / anchor fasteners etc. ( composite ) 28.1 cable jointing straight through jointing for 1.1 kv pvc insulated al / copper conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.1.1 3.5 x 10 sq. mm copper ( only supply ) 28.1.2 3.5 x 10 sq. mm copper ( only labour ) 28.1.3 3.5 x 10 sq. mm copper ( composite ) 28.1.4 3.5 x 16 sq. mm copper ( only supply ) 28.1.5 3.5 x 16 sq. mm copper ( only labour ) 28.1.6 3.5 x 16 sq. mm copper ( composite ) 28.1.7 3.5 x 25 sq. mm copper ( only supply ) 28.1.8 3.5 x 25 sq. mm copper ( only labour ) 28.1.9 3.5 x 25 sq. mm copper ( composite ) 28.1.10 3.5 x 35 sq. mm copper ( only supply ) 28.1.11 3.5 x 35 sq. mm copper ( only labour ) 28.1.12 3.5 x 35 sq. mm copper ( composite ) 28.1.13 3.5 x 50 sq. mm copper ( only supply ) 28.1.14 3.5 x 50 sq. mm copper ( only labour ) 28.1.15 3.5 x 50 sq. mm copper ( composite ) 28.1.16 3.5 x 70 sq. mm copper ( only supply ) 28.1.17 3.5 x 70 sq. mm copper ( only labour ) 28.1.18 3.5 x 70 sq. mm copper ( composite ) 28.1.19 3.5 x 95 sq. mm copper ( only supply ) 28.1.20 3.5 x 95 sq. mm copper ( only labour ) 28.1.21 3.5 x 95 sq. mm copper ( composite ) 28.1.22 3.5 x 120 sq. mm copper ( only supply ) 28.1.23 3.5 x 120 sq. mm copper ( only labour ) 28.1.24 3.5 x 120 sq. mm copper ( composite ) 28.1.25 3.5 x 150 sq. mm copper ( only supply ) 28.1.26 3.5 x 150 sq. mm copper ( only labour ) 28.1.27 3.5 x 150 sq. mm copper ( composite ) 28.1.28 3.5 x 185 sq. mm copper ( only supply ) 28.1.29 3.5 x 185 sq. mm copper ( only labour ) 28.1.30 3.5 x 185 sq. mm copper ( composite ) 28.1.31 3.5 x 240 sq. mm copper ( only supply ) 28.1.32 3.5 x 240 sq. mm copper ( only labour ) 28.1.33 3.5 x 240 sq. mm copper ( composite ) 28.1.34 3.5 x 300 sq. mm copper ( only supply ) 28.1.35 3.5 x 300 sq. mm copper ( only labour ) 28.1.36 3.5 x 300 sq. mm copper ( composite ) 28.1.37 3.5 x 400 sq. mm copper ( only supply ) 28.1.38 3.5 x 400 sq. mm copper ( only labour ) 28.1.39 3.5 x 400 sq. mm copper ( composite ) 28.2 straight through jointing for 11 / 33 kv xlpe insulated al conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.2.1 as described above, 11kv, 3 x 240 sq.mm xlpe ( only supply ) 28.2.2 as described above, 11kv, 3 x 240 sq.mm xlpe ( only labour ) 28.2.3 as described above, 11kv, 3 x 240 sq.mm xlpe ( composite ) 28.2.4 as described above, 33kv, 3 x 300 sq. mm xlpe ( only supply ) 28.2.5 as described above, 33kv, 3 x 300 sq. mm xlpe ( only labour ) 28.2.6 as described above, 33kv, 3 x 300 sq. mm xlpe ( composite ) 29.1 switch board for ac pointfabrication / & supply, installation. testing & commissioning of ms box made out of 16 / 14 swg ms sheet with removable top cover of 3 mm white hylam sheet / ms sheet with screws, cup washer etc. & complete concealed in wall with their following accessories mounted on it & their inter connection with 2.5 / 4 sq. mm pvc insulated copper cord wire. all as required & as directed by o i c, es. 29.1.1 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only supply ) 29.1.2 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only labour ) 29.1.3 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( composite ) 29.1.4 as per item no 29.1 but for 40 amps dp mcb & socket ( only supply ) 29.1.5 as per item no 29.1 but for 40 amps dp mcb & socket ( only labour ) 29.1.6 as per item no 29.1 but for 40 amps dp mcb & socket ( composite ) 29.1.7 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only supply ) 29.1.8 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only labour ) 29.1.9 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( composite ) 29.2 replacement for item no 29.1 29.2.1 replacement of 20 amps, reroll type metallic spn sockets ( only supply ) 29.2.2 replacement of 20 amps, reroll type metallic spn sockets ( only labour ) 29.2.3 replacement of 20 amps, reroll type metallic spn sockets ( composite ) 29.2.4 replacement of 32 amps, reroll type metallic spn sockets ( only supply ) 29.2.5 replacement of 32 amps, reroll type metallic spn sockets ( only labour ) 29.2.6 replacement of 32 amps, reroll type metallic spn sockets ( composite ) 29.2.7 replacement of 40 amps, reroll type metallic spn sockets ( only supply ) 29.2.8 replacement of 40 amps, reroll type metallic spn sockets ( only labour ) 29.2.9 replacement of 40 amps, reroll type metallic spn sockets ( composite ) 29.2.10 replacement of 63 amps, reroll type metallic spn sockets ( only supply ) 29.2.11 replacement of 63 amps, reroll type metallic spn sockets ( only labour ) 29.2.12 replacement of 63 amps, reroll type metallic spn sockets ( composite ) 29.2.13 supply & fixing metallic top for 10 amps 2p+e ( only supply ) 29.2.14 supply & fixing metallic top for 10 amps 2p+e ( only labour ) 29.2.15 supply & fixing metallic top for 10 amps 2p+e ( composite ) 29.2.16 as per item no 29.2.13 but for 20 amps ( only supply ) 29.2.17 as per item no 29.2.13 but for 20 amps ( only labour ) 29.2.18 as per item no 29.2.13 but for 20 amps ( composite ) 29.2.19 as per item no 29.2.13 but for 32 amps ( only supply ) 29.2.20 as per item no 29.2.13 but for 32 amps ( only labour ) 29.2.21 as per item no 29.2.13 but for 32 amps ( composite ) 29.2.22 as per item no 29.2.13 but for 40 amps ( only supply ) 29.2.23 as per item no 29.2.13 but for 40 amps ( only labour ) 29.2.24 as per item no 29.2.13 but for 40 amps ( composite ) 29.2.25 supplying & fixing metallic top 32 amps, 3 p + e ( only supply ) 29.2.26 supplying & fixing metallic top 32 amps, 3 p + e ( only labour ) 29.2.27 supplying & fixing metallic top 32 amps, 3 p + e ( composite ) 29.2.28 spike guard of approved make for computer ( only supply ) 29.2.29 heavy duty spike guard of approved make for equipments ( only supply ) 30.1 distribution boards providing & erecting distribution made out of 2 mm thick ( in case of fabrication ) ms crca sheet with concealed hinges, mounted on ms angle frame & grouted on the wall / fixed on the coloum with anchor fastener with earthing terminal, neutral link, interconnection with adequate size of bus bar / wires, interior of the db shall be covered with 3 mm thick frp sheet with necessary cut out, neoprene gasket, painting with seven tank metal treatment process ( shade to be got approved ) / powder coating all as per instructions of e i c, complete in all respect. 30.1.1.1 lighting distribution boardsall as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only supply ) 30.1.1.2 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only labour ) 30.1.1.3 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( composite ) 30.1.1.4 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only supply ) 30.1.1.5 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only labour ) 30.1.1.6 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( composite ) 30.1.2 power distribution boards 30.1.2.1 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only supply ) 30.1.2.2 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only labour ) 30.1.2.3 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( composite ) 30.1.2.4 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only supply ) 30.1.2.5 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only labour ) 30.1.2.6 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( composite ) 30.1.3 ready made distribution boards supply, erection, testing & commissioning of sheet metal powered coated distribution boards inclusive of mcbs with bus bar, neutral link & connection wire set etc of mds / siemens make confirming to ip 42. all as required & directed by o i c, es with prior approval. 30.1.3.1 spn 4 way ( only supply ) 30.1.3.2 spn 4 way ( only labour ) 30.1.3.3 spn 4 way ( composite ) 30.1.3.4 spn 6 way ( only supply ) 30.1.3.5 spn 6 way ( only labour ) 30.1.3.6 spn 6 way ( composite ) 30.1.3.7 spn 8 way ( only supply ) 30.1.3.8 spn 8 way ( only labour ) 30.1.3.9 spn 8 way ( composite ) 30.1.3.10 spn 12 way ( only supply ) 30.1.3.11 spn 12 way ( only labour ) 30.1.3.12 spn 12 way ( composite ) 30.1.3.13 tpn 4 way ( only supply ) 30.1.3.14 tpn 4 way ( only labour ) 30.1.3.15 tpn 4 way ( composite ) 30.1.3.16 tpn 6 way ( only supply ) 30.1.3.17 tpn 6 way ( only labour ) 30.1.3.18 tpn 6 way ( composite ) 30.1.3.19 tpn 8 way ( only supply ) 30.1.3.20 tpn 8 way ( only labour ) 30.1.3.21 tpn 8 way ( composite ) 30.1.3.22 tpn 12 way ( only supply ) 30.1.3.23 tpn 12 way ( only labour ) 30.1.3.24 tpn 12 way ( composite ) 30.1.4.1 aluminum anodized name plates for circuit identification with prior approval. ( only supply ) 30.1.4.2 aluminum anodized name plates for circuit identification with prior approval. ( only labour ) 30.1.4.3 aluminum anodized name plates for circuit identification with prior approval. ( only composite ) 31.1 pvc boardssupply, installation of suitable size of pvc board of approved make with necessary fixing arrangement doene by suitable screwing on any kind of surface for installing accessories like switches, sockets, regulators oe nay other similar application as per the instructions and as directed by e i c, es 31.1.1 4 x 4 ( only supply ) 31.1.2 4 x 4 ( only labour ) 31.1.3 4 x 4 ( composite ) 31.1.4 4 x 6 ( only supply ) 31.1.5 4 x 6 ( only labour ) 31.1.6 4 x 6 ( composite ) 31.1.7 4 x 7 ( only supply ) 31.1.8 4 x 7 ( only labour ) 31.1.9 4 x 7 ( composite ) 31.1.10 6 x 6 ( only supply ) 31.1.11 6 x 6 ( only labour ) 31.1.12 6 x 6 ( composite ) 31.1.13 6 x 8 ( only supply ) 31.1.14 6 x 8 ( only labour ) 31.1.15 6 x 8 ( composite ) 31.1.16 8 x 10 ( only supply ) 31.1.17 8 x 10 ( only labour ) 31.1.18 8 x 10 ( composite ) 31.1.19 10 x 12 ( only supply ) 31.1.20 10 x 12 ( only labour ) 31.1.21 10 x 12 ( composite ) 31.1.22 12 x 12 ( only supply ) 31.1.23 12 x 12 ( only labour ) 31.1.24 12 x 12 ( composite ) 31.1.25 3.5 x 6 ( only supply ) 31.1.26 3.5 x 6 ( only labour ) 31.1.27 3.5 x 6 ( composite ) 31.1.28 3.5 x 8 ( only supply ) 31.1.29 3.5 x 8 ( only labour ) 31.1.30 3.5 x 8 ( composite ) 31.1.31 3.5 x 10 ( only supply ) 31.1.32 3.5 x 10 ( only labour ) 31.1.33 3.5 x 10 ( composite ) 31.1.34 3.5 x 12 ( only supply ) 31.1.35 3.5 x 12 ( only labour ) 31.1.36 3.5 x 12 ( composite ) 32 mcbs / mccbs / sfus / isolators 32.1 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box & lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.1.1. as per item no 32.1 for– 32 a ( only supply ) 32.1.2 as per item no 32.1 for– 32 a ( only labour ) 32.1.3. as per item no 32.1 for– 32 a ( composite ) 32.1.4 as per item no 32.1 but for– 63 a ( only supply ) 32.1.5. as per item no 32.1 but for– 63 a ( only labour ) 32.1.6 as per item no 32.1 but for– 63 a ( composite ) 32.1.7. as per item no 32.1 but for– 100 a ( only supply ) 32.1.8 as per item no 32.1 but for– 100 a ( only labour ) 32.1.9 as per item no 32.1 but for– 100 a ( composite ) 32.1.10 as per item no 32.1 but for– 200 a ( only supply ) 32.1.11. as per item no 32.1 but for– 200 a ( only labour ) 32.1.12 as per item no 32.1 but for– 200 a ( composite ) 32.1.13 as per item no 32.1 but for 250 a ( only supply ) 32.1.14 as per item no 32.1 but for 250 a ( only labour ) 32.1.15 as per item no 32.1 but for 250 a ( composite ) 32.1.16 as per item no 32.1 but for 400 a ( only supply ) 32.1.17 as per item no 32.1 but for 400 a ( only labour ) 32.1.18 as per item no 32.1 but for 400 a ( composite ) 32.1.19 as per item no 32.1 but for 630 a ( only supply ) 32.1.20 as per item no 32.1 but for 630 a ( only labour ) 32.1.21 as per item no 32.1 but for 630 a ( composite ) 32.2 supply, fixing, testing & commissioning of c curve mcb with enclosure & connected with provided leads on incoming & outgoing side with all fixing arrangemet etc duly completed approved manner, all as per instruction and as directed by e i c, es. 32.2.1 as per item no 32.2 for– 6 a sp ( only supply ) 32.2.2 as per item no 32.2 for– 6 a sp ( only labour ) 32.2.3 as per item no 32.2 for– 6 a sp ( composite ) 32.2.4 as per item no 32.2 but for– 16 a sp ( only supply ) 32.2.5 as per item no 32.2 but for– 16 a sp ( only labour ) 32.2.6 as per item no 32.2 but for– 16 a sp ( composite ) 32.2.7 as per item no 32.2 but for– 20 a sp ( only supply ) 32.2.8 as per item no 32.2 but for– 20 a sp ( only labour ) 32.2.9 as per item no 32.2 but for– 20 a sp ( composite ) 32.2.10 as per item no 32.2 but for– 32 a sp ( only supply ) 32.2.11 as per item no 32.2 but for– 32 a sp ( only labour ) 32.2.12 as per item no 32.2 but for– 32 a sp ( composite ) 32.2.13 as per item no 32.2 but for– 20 a dp ( only supply ) 32.2.14 as per item no 32.2 but for– 20 a dp ( only labour ) 32.2.15 as per item no 32.2 but for– 20 a dp ( composite ) 32.2.16 as per item no 32.2 but for– 32 a dp ( only supply ) 32.2.17 as per item no 32.2 but for– 32 a dp ( only labour ) 32.2.18 as per item no 32.2 but for– 32 a dp ( composite ) 32.2.19 as per item no 32.2 but for– 40 a dp ( only supply ) 32.2.20 as per item no 32.2 but for– 40 a dp ( only labour ) 32.2.21 as per item no 32.2 but for– 40 a dp ( composite ) 32.2.22 as per item no 32.2 but for– 63 a dp ( only supply ) 32.2.23 as per item no 32.2 but for– 63 a dp ( only labour ) 32.2.24 as per item no 32.2 but for– 63 a dp ( composite ) 32.2.25 as per item no 32.2 but for– 32 a tp ( only supply ) 32.2.26 as per item no 32.2 but for– 32 a tp ( only labour ) 32.2.27 as per item no 32.2 but for– 32 a tp ( composite ) 32.2.28 as per item no 32.2 but for– 40 a tp ( only supply ) 32.2.29 as per item no 32.2 but for– 40 a tp ( only labour ) 32.2.30 as per item no 32.2 but for– 40 a tp ( composite ) 32.2.31 all as per item no 30.1 for 63 a tp ( only supply ) 32.2.32 as per item no 32.2 but for– 63 a tp ( only labour ) 32.2.33 as per item no 32.2 but for– 63 a tp ( composite ) 32.2.34 as per item no 32.2 but for32 a, 4 pole ( only supply ) 32.2.35 as per item no 32.2 but for32 a, 4 pole ( only labour ) 32.2.36 as per item no 32.2 but for32 a, 4 pole ( composite ) 32.2.37 as per item no 32.2 but for40 a, 4 pole ( only supply ) 32.2.38 as per item no 32.2 but for40 a, 4 pole ( only labour ) 32.2.39 as per item no 32.2 but for40 a, 4 pole ( composite ) 32.2.40 as per item no 32.2 but for63 a, 4 pole ( only supply ) 32.2.41 as per item no 32.2 but for63 a, 4 pole ( only labour ) 32.2.42 as per item no 32.2 but for63 a, 4 pole ( composite ) 32.2.43 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only supply ) 32.2.44 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only labour ) 32.2.45 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( composite ) 32.3 supply, fixing, testing & commissioning of tpn sfu in sheet steel enclosure of reputed make with suitable hrc fuses and to be connected with provided list with all necessary fixing arrangement as as per instrructions and as directed by e i c, es. 32.3.1 32 a, 415 v, ac ( only supply ) 32.3.2 32 a, 415 v, ac ( only labour ) 32.3.3 32 a, 415 v, ac ( composite ) 32.3.4 63 a, 415 v, ac ( only supply ) 32.3.5 63 a, 415 v, ac ( only labour ) 32.3.6 63 a, 415 v, ac ( composite ) 32.3.7 125 a, 415 v, ac ( only supply ) 32.3.8 125 a, 415 v, ac ( only labour ) 32.3.9 125 a, 415 v, ac ( composite ) 32.3.10 200 a, 415 v, ac ( only supply ) 32.3.11 200 a, 415 v, ac ( only labour ) 32.3.12 200 a, 415 v, ac ( composite ) 32.3.14 250 a, 415 v, ac ( only labour ) 32.3.15 250 a, 415 v, ac ( composite ) 32.3.16 315 a, 415 v, ac ( only supply ) 32.3.17 315 a, 415 v, ac ( only labour ) 32.3.18 315 a, 415 v, ac ( composite ) 32.3.19 400 a, 415 v, ac ( only supply ) 32.3.20 400 a, 415 v, ac ( only labour ) 32.3.21 400 a, 415 v, ac ( composite ) 32.3.22 630 a, 415 v, ac ( only supply ) 32.3.23 630 a, 415 v, ac ( only labour ) 32.3.24 630 a, 415 v, ac ( composite ) 32.4 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.4.1 as per item no 32.4 for 1000 a ( only supply ) 32.4.2 as per item no 32.4 for 1000 a ( only labour ) 32.4.3 as per item no 32.4 for 1000 a ( composite ) 32.4.4 as per item no 32.4 but for 800 a ( only supply ) 32.4.5 as per item no 32.4 but for 800 a ( only labour ) 32.4.6 as per item no 32.4 but for 800 a ( composite ) 32.5 providing, fixing, testing & commissioning of reputed make tpn isolator with provided leads incoming & outgoing side with all necessary fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.5.1 as per item no 32.5 for 400 a ( only supply ) 32.5.2 as per item no 32.5 for 400 a ( only labour ) 32.5.3 as per item no 32.5 for 400 a ( composite ) 32.5.4 as per item no 32.5 but for 250 a ( only supply ) 32.5.5 as per item no 32.5 but for 250 a ( only labour ) 32.5.6 as per item no 32.5 but for 250 a ( composite ) 32.5.7 as per item no 32.5 but for 125 a ( only supply ) 32.5.8 as per item no 32.5 but for 125 a ( only labour ) 32.5.9 as per item no 32.5 but for 125 a ( composite ) 32.5.10 as per item no 32.5 but for 63 a ( only supply ) 32.5.11 as per item no 32.5 but for 63 a ( only labour ) 32.5.12 as per item no 32.5 but for 63 a ( composite ) 32.6 providing, fixing, testing & commissioning of reputed make tpn sfu with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.6.1 as per item no 32.6 for 630 a ( only supply ) 32.6.2 as per item no 32.6 for 630 a ( only labour ) 32.6.3 as per item no 32.6 for 630 a ( composite ) 32.6.4 as per item no 32.6 but for 400 a ( only supply ) 32.6.5 as per item no 32.6 but for 400 a ( only labour ) 32.6.6 as per item no 32.6 but for 400 a ( composite ) 32.6.7 as per item no 32.6 but for 250 a ( only supply ) 32.6.8 as per item no 32.6 but for 250 a ( only labour ) 32.6.9 as per item no 32.6 but for 250 a ( composite ) 32.6.10 as per item no 32.6 but for 125 a ( only supply ) 32.6.11 as per item no 32.6 but for 125 a ( only labour ) 32.6.12 as per item no 32.6 but for 125 a ( composite ) 32.6.13 as per item no 32.6 but for 200 a ( only supply ) 32.6.14 as per item no 32.6 but for 200 a ( only labour ) 32.6.15 as per item no 32.6 but for 200 a ( composite ) 32.6.16 as per item no 32.6 but for 63 a ( only supply ) 32.6.17 as per item no 32.6 but for 63 a ( only labour ) 32.6.18 as per item no 32.6 but for 63 a ( composite ) 32.6.19 as per item no 32.6 but for 32 a ( only supply ) 32.6.20 as per item no 32.6 but for 32 a ( only labour ) 32.6.21 as per item no 32.6 but for 32 a ( composite ) 32.7 providing, fixing, testing & commissioning of reputed make tpn mcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner all asper instructions and as diredtec by e i c, es. 32.7.1 all as per item no 32.7 for 63 a ( only supply ) 32.7.2 all as per item no 32.7 for 63 a ( only labour ) 32.7.3 all as per item no 32.7 for 63 a ( composite ) 32.7.4 all as per item no 32.7 for 32 a ( only supply ) 32.7.5 all as per item no 32.7 for 32 a ( only labour ) 32.7.6 all as per item no 32.7 for 32 a ( composite ) 32.8 providing, fixing, testing & commissioning of reputed dp mcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.8.1 all as per item no 32.8 for 63 a ( only supply ) 32.8.2 all as per item no 32.8 for 63 a ( only labour ) 32.8.3 all as per item no 32.8 for 63 a ( composite ) 32.8.4 all as per item no 32.8 but for 40 a ( only supply ) 32.8.5 all as per item no 32.8 but for 40 a ( only labour ) 32.8.6 all as per item no 32.8 but for 40 a ( composite ) 32.8.7 all as per item no 32.8 but for 32 a ( only supply ) 32.8.8 all as per item no 32.8 but for 32 a ( only labour ) 32.8.9 all as per item no 32.8 but for 32 a ( composite ) 32.8.10 all as per item no 32.8 but for 20 a ( only supply ) 32.8.11 all as per item no 32.8 but for 20 a ( only labour ) 32.8.12 all as per item no 32.8 but for 20 a ( composite ) 32.8.13 all as per item no 32.8 but for 16 a ( only supply ) 32.8.14 all as per item no 32.8 but for 16 a ( only labour ) 32.8.15 all as per item no 32.8 but for 16 a ( composite ) 32.9 providing, fixing, testing & commissioning of reputed make dp elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es 32.9.1 all as per item no 32.9 for 63 a ( only supply ) 32.9.2 all as per item no 32.9 for 63 a ( only labour ) 32.9.3 all as per item no 32.9 for 63 a ( composite ) 32.9.4 all as per item no 32.9 but for 40 a ( only supply ) 32.9.5 all as per item no 32.9 but for 40 a ( only labour ) 32.9.6 all as per item no 32.9 but for 40 a ( composite ) 32.9.7 all as per item no 32.9 but for 25 a ( only supply ) 32.9.8 all as per item no 32.9 but for 25 a ( only labour ) 32.9.9 all as per item no 32.9 but for 25 a ( composite ) 32.10.a providing, fixing, testing & commissioning of reputed make 4 pole elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es. 32.10.1 all as per item no 32.10 for 63 a ( only supply ) 32.10.2 all as per item no 32.10 for 63 a ( only labour ) 32.10.3 all as per item no 32.10 for 63 a ( composite ) 32.10.4 all as per item no 32.10 but for 40 a ( only supply ) 32.10.5 all as per item no 32.10 but for 40 a ( only labour ) 32.10.6 all as per item no 32.10 but for 40 a ( composite ) 32.11 providing, fixing, testing & commissioning of reputed make sp mcb with provided leads on incoming & outgoing side with fixing arrangementduly completed in approved manner all as per instructions and as directed by e i c, es. 32.11.1 all as per item no 32.11 for 40 / 63a ( only supply ) 32.11.2 all as per item no 32.11 for 40 / 63a ( only labour ) 32.11.3 all as per item no 32.11 for 40 / 63a ( composite ) 32.11.4 all as per item no 32.11 but for 32 a ( only supply ) 32.11.5 all as per item no 32.11 but for 32 a ( only labour ) 32.11.6 all as per item no 32.11 but for 32 a ( composite ) 32.11.7 all as per item no 32.11 but for 20 a ( only supply ) 32.11.8 all as per item no 32.11 but for 20 a ( only labour ) 32.11.9 all as per item no 32.11 but for 20 a ( composite ) 32.11.10 all as per item no 32.11 but for 16 a ( only supply ) 32.11.11 all as per item no 32.11 but for 16 a ( only labour ) 32.11.12 all as per item no 32.11 but for 16 a ( composite ) 32.11.13 all as per item no 32.11 but for 6 a ( only supply ) 32.11.14 all as per item no 32.11 but for 6 a ( only labour ) 32.11.15 all as per item no 32.11 but for 6 a ( composite ) 32.12 providing, fixing, testing & commissioning of reputed make tpn mcb+elcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es 32.12.1 all as per item no 32.12 for 32 a ( only supply ) 33.1 ct / pt and other panel componentsproviding, fixing, testing & commissioning of reputed make ct with provided bus bar on incoming & leads on outgoing side duly completed in approved manner. class 1, 15 va, resin cast, bar primary type. 33.2 supply, fixing, testing and commissioning of various sizes of annunciator panel as mentioned below with test, accepts, reset push button, supply on indication with necessary fixing arrangement, all as per instructions and as directed by e i c, es. ( prior approval is required ) 33.3 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only supply ) 33.3.1 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only labour ) 33.3.2 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( composite ) 33.4 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only supply ) 33.4.1 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only labour ) 33.4.2 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only composite ) 33.5 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.5.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.5.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.6 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.6.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.6.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.7 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.7.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.7.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.8 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.8.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.8.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.9 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.9.1 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.9.2 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 33.10.a providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.10.1 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.10.2 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 34.1 panel accessories providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only supply ) 34.1.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only labour ) 34.1.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( composite ) 34.2.0 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only supply ) 34.2.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only labour ) 34.2.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg.scale mi type for various ct ratings. ( composite ) 34.2.3 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.4 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.5 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.2.6 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.7 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.8 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.3.a providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only supply ) 34.3.1 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only labour ) 34.3.2 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( composite ) 34.4 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only supply ) 34.4.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only labour ) 34.4.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( composite ) 34.5 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( only supply ) 34.5.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg.scale mi type for above said ct ratings. ( item no. 8. ) ( only labour ) 34.5.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( composite ) 34.6 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only supply ) 34.6.1 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only labour ) 34.6.2 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( composite ) 34.6.3 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.4 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps.. ( only labour ) 34.6.5 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( composite ) 34.6.6 providing, fixing, testing & commissioning of three phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.7 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( only labour ) 34.6.8 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( composite ) 34.7 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only supply ) 34.7.1 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only labour ) 34.7.2 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( composite ) 34.8 providing, fixing, testing & commissioning of analog pf meter ( only supply ) 34.8.1 providing, fixing, testing & commissioning of analog pf meter ( only labour ) 34.8.2 providing, fixing, testing & commissioning of analog pf meter ( composite ) 34.9 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only supply ) 34.9.1 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only labour ) 34.9.2 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( composite ) 34.10.a providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only supply ) 34.10.1 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only labour ) 34.10.2 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( composite ) 34.11 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only supply ) 34.11.1 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only labour ) 34.11.2 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( composite ) 34.12 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only supply ) 34.12.1 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only labour ) 34.12.2 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( composite ) 34.13 providing, fixing, testing & commissioning of auto / mannual selector switch ( only supply ) 34.13.1 providing, fixing, testing & commissioning of auto / mannual selector switch ( only labour ) 34.13.2 providing, fixing, testing & commissioning of auto / mannual selector switch ( only composite ) 34.14 providing, fixing, testing & commissioning of 2p2w rotary switch ( only supply ) 34.14.1 providing, fixing, testing & commissioning of 2p2w rotary switch ( only labour ) 34.14.2 providing, fixing, testing & commissioning of 2p2w rotary switch ( composite ) 34.15 providing, fixing, testing & commissioning of 3p3w rotary switch ( only supply ) 34.15.1 providing, fixing, testing & commissioning of 3p3w rotary switch ( only labour ) 34.15.2 providing, fixing, testing & commissioning of 3p3w rotary switch ( composite ) 34.16 providing, fixing, testing & commissioning of 1 way toggle switch ( only supply ) 34.16.1 providing, fixing, testing & commissioning of 1 way toggle switch ( only labour ) 34.16.2 providing, fixing, testing & commissioning of 1 way toggle switch ( composite ) 34.17 providing, fixing, testing & commissioning of 2 way toggle switch ( only supply ) 34.17.1 providing, fixing, testing & commissioning of 2 way toggle switch ( only labour ) 34.17.2 providing, fixing, testing & commissioning of 2 way toggle switch ( composite ) 34.18 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only supply ) 34.18.1 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only labour ) 34.18.2 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( composite ) 34.19 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only supply ) 34.19.1 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only labour ) 34.19.2 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( composite ) 34.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only supply ) 34.20.1 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only labour ) 34.20.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( composite ) 34.21 providing, fixing, testing & commissioning of indicating lamp, led type. 34.21.1 for red, orange, yellow, off white, green coloured led lamp ( only supply ) 34.21.2 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.3 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.4 as per item no 34.21 but for blue coluored led lamp ( only supply ) 34.21.5 as per item no 34.21 but for blue coluored led lamp ( only labour ) 34.21.6 as per item no 34.21 but for blue coluored led lamp ( composite ) 34.21.7 providing and fixing of centrifugal switch ( only supply ) 34.21.8 providing and fixing of centrifugal switch ( only labour ) 34.21.9 providing and fixing of centrifugal switch ( composite ) 34.22 providing, fixing, testing & commissioning of push buttons ( only supply ) 34.22.1 providing, fixing, testing & commissioning of push buttons ( only labour ) 34.22.2 providing, fixing, testing & commissioning of push buttons ( composite ) 34.23 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only supply ) 34.23.1 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only labour ) 34.23.2 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( composite ) 34.24 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230 v ac. ( only supply ) 34.24.1 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( only labour ) 34.24.2 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( composite ) 34.24.3 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only supply ) 34.24.4 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only labour ) 34.24.5 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( composite ) 34.24.6 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only supply ) 34.24.7 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only labour ) 34.24.8 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( composite ) 34.25 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only supply ) 34.25.1 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only labour ) 34.25.2 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( composite ) 34.26 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.26.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.26.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.27 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.27.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.27.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.28 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only supply ) 34.28.1 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only labour ) 34.28.2 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( composite ) 34.29 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only supply ) 34.29.1 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only labour ) 34.29.2 thermo stat for space heatre 240 v ac, 30 deg. to 90 deg. ( composite ) 34.30 supply and fixing of 240 v ac, hooter cands make ( only supply ) 34.30.1 supply and fixing of240 v ac, hooter cands make ( only labour ) 34.30.2 supply and fixing of240 v ac, hooter cands make ( composite ) 34.31 providing 33 kv resin cast type ct for 33 kv panel. ratio 600 / 5 5 5 amps.burdun 15 va, class 1 / 5p10 / ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 34.31.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 34.31.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 34.32 providing dc power pack with battery backup ( only supply ) 34.32.1 providing dc power pack with battery backup ( only labour ) 34.32.2 providing dc power pack with battery backup ( composite ) 35 electrical accessories supply, fixing, testing and commissioning of the following electrical accessories on the hylam sheet / modular plates / pvc board etc or as directed by wherever required including appropriate size of copper conductor of pvc wires interconnection using lugs, insulatin tape etc. in complete manner as directed by e i c, es with prior approval. procurement of these items shall be done in accordence with approved makes. approval shall be sought from e i c, es for other brand or make. in case of reeplacement, old / removed items shall be handed over to e i c, es as it is. agency has to supply material as per existing makes as site linke anchor / roma precision etc. 35.1.1 6 amp, , flush type s / w ( only supply ) 35.1.2 6 amp, , flush type s / w ( only labour ) 35.1.3 6 amp, , flush type s / w ( composite ) 35.1.4 6 amp, , 3 pin socket ( only supply ) 35.1.5 6 amp, , 3 pin socket ( only labour ) 35.1.6 6 amp, , 3 pin socket ( composite ) 35.1.7 16 amp, , switch ( only supply ) 35.1.8 16 amp, , switch ( only labour ) 35.1.9 16 amp, , switch ( composite ) 35.1.10 16 amp, , 3 pin socket ( only supply ) 35.1.11 16 amp, , 3 pin socket ( only labour ) 35.1.12 16 amp, , 3 pin socket ( composite ) 35.1.13 16 amp, , 5 pin socket ( only supply ) 35.1.14 16 amp, , 5 pin socket ( only labour ) 35.1.15 16 amp, , 5 pin socket ( composite ) 35.1.16 6 amp, top ( only supply ) 35.1.17 6 amp, top ( only labour ) 35.1.18 6 amp, top ( composite ) 35.1.19 16 amp, top ( only supply ) 35.1.20 16 amp, top ( only labour ) 35.1.21 16 amp, top ( composite ) 35.1.22 6 amp, two way switch , make precision ( only supply ) 35.1.23 6 amp, two way switch , make precision ( only labour ) 35.1.24 6 amp, two way switch , make precision ( composite ) 35.1.25 16 amp two way switch ( only supply ) 35.1.26 16 amp two way switch ( only labour ) 35.1.27 16 amp two way switch ( composite ) 35.1.28 16 amp, 5 pin, switch socket combination board ( only supply ) 35.1.29 16 amp, 5 pin, switch socket combination board ( only labour ) 35.1.30 16 amp, 5 pin, switch socket combination board ( composite ) 35.1.31 2x15a, 5pin, switch socket combination board ( only supply ) 35.1.32 2x15a, 5pin, switch socket combination board ( only labour ) 35.1.33 2x15a, 5pin, switch socket combination board ( composite ) 35.1.34 6 amp, bell push ( only supply ) , 35.1.35 6 amp, bell push ( only labour ) 35.1.36 6 amp, bell push ( composite ) 35.1.37 ceiling rose ( only supply ) 35.1.38 ceiling rose ( only labour ) 35.1.39 ceiling rose ( composite ) 35.1.40 angle holder ( only supply ) 35.1.41 angle holder ( only labour ) 35.1.42 angle holder ( composite ) 35.1.43 batten holder ( only supply ) 35.1.44 batten holder ( only labour ) 35.1.45 batten holder ( composite ) 35.1.46 bell with indication, reset push button ( only supply ) 35.1.47 bell with indication, reset push button ( only labour ) 35.1.48 bell with indication, reset push button ( composite ) 35.1.49 buzzer of any approved make ( only supply ) 35.1.50 buzzer of any approved make ( only labour ) 35.1.51 buzzer of any approved make ( composite ) 35.1.52 3 pin telephone socket, ( only supply ) 35.1.53 3 pin telephone socket, ( only labour ) 35.1.54 3 pin telephone socket, ( composite ) 35.1.55 telephone socket ( rj – 11 jack ) ( only supply ) 35.1.56 telephone socket ( rj – 11 jack ) ( only labour ) 35.1.57 telephone socket ( rj – 11 jack ) ( composite ) 35.1.58 rj 45 jack socket ( only supply ) 35.1.59 rj 45 jack socket ( only labour ) 35.1.60 rj 45 jack socket ( composite ) 35.1.61 rj 11 pin ( only supply ) 35.1.62 rj 11 pin ( only labour ) 35.1.63 rj 11 pin ( composite ) 35.1.64 rj 45 pin ( only supply ) 35.1.65 rj 45 pin ( only labour ) 35.1.66 rj 45 pin ( composite ) 35.1.67 telephone 3 pin plug top ( only supply ) 35.1.68 telephone 3 pin plug top ( only labour ) 35.1.69 telephone 3 pin plug top ( composite ) 35.1.70 tv socket ( only supply ) 35.1.71 tv socket ( only labour ) 35.1.72 tv socket ( composite ) 35.1.73 tv pin ( male+ female ) ( only supply ) 35.1.74 tv pin ( male+ female ) ( only labour ) 35.1.75 tv pin ( male+ female ) ( compositey ) 35.1.76 tv connector ( splitter ) 35.1.77 as per item no 35.1.76 for 2 way ( only supply ) 35.1.78 as per item no 35.1.76 for 2 way ( only labour ) 35.1.79 as per item no 35.1.76 for 2 way ( composite ) 35.1.80 as per item no 35.1.76 but for 3 way ( only supply ) 35.1.81 as per item no 35.1.76 but for 3 way ( only labour ) 35.1.82 as per item no 35.1.76 but for 3 way ( composite ) 35.1.83 as per item no 35.1.76 but for 4 way ( only supply ) 35.1.84 as per item no 35.1.76 but for 4 way ( only labour ) 35.1.85 as per item no 35.1.76 but for 4 way ( composite ) 35.1.86 tv cable gland for rj 11 ( only supply ) 35.1.87 tv cable gland for rj 11 ( only labour ) 35.1.88 tv cable gland for rj 11 ( composite ) 35.1.89 glass fuse, 2 a / 4a ( only supply ) 35.1.90 glass fuse, 2 a / 4a ( only labour. ) 35.1.91 glass fuse, 2 a / 4a ( composite ) 35.1.92 glass fuse 6a / 10 a ( only supply ) 35.1.93 glass fuse 6a / 10 a ( only labour ) 35.1.94 glass fuse 6a / 10 a ( composite ) 35.1.95 250 w, , ceiling fan regulator ( only supply ) 35.1.96 250 w, , ceiling fan regulator ( only labour ) 35.1.97 250 w, , ceiling fan regulator ( composite ) 35.1.98 300 w, , ceiling fan regulator ( only suppply ) 35.1.99 300 w, , ceiling fan regulator ( only labour ) 35.1.100 300 w, , ceiling fan regulator ( composite ) 35.1.101 750 w, , ceiling fan regulator ( only supply ) 35.1.102 750 w, , ceiling fan regulator ( only labur ) 35.1.103 750 w, , ceiling fan regulator ( composite ) 35.1.104 1000 w, , ceiling fan regulator ( only supply ) 35.1.105 1000 w, , ceiling fan regulator ( only labour ) 35.1.106 1000 w, ceiling fan regulator ( composite ) 35.1.107 iron connector flat / round ( only supply ) 35.1.108 iron connector flat / round ( only labour ) 35.1.109 iron connector flat / round ( composite ) 35.1.110 industrial alarm bell ( only supply ) 35.1.111 industrial alarm bell ( only labour ) 35.1.112 industrial alarm bell ( composite ) 35.1.113 25 amps, dp switch flush type with neon indication. ( only supply ) 35.1.114 25 amps, dp switch flush type with neon indication. ( only labour ) 35.1.115 25 amps, dp switch flush type with neon indication. ( composite ) 35.1.116 32 amps, dp switch flush type with neon indication ( only supply ) 35.1.117 32 amps, dp switch flush type with neon indication ( only labour ) 35.1.118 32 amps, dp switch flush type with neon indication ( composite ) 35.1.119 glass for halogen fittings. ( only supply ) 35.1.120 glass for halogen fittings. ( only labour ) 35.1.121 glass for halogen fittings. ( composite ) 35.1.122 speed regulator h 70 k ohm ( only supply ) 35.1.123 speed regulator h 70 k ohm ( only labour ) 35.1.124 speed regulator h 70 k ohm ( composite ) 35.1.125 regulator for hoods as per sample ) ( only supply ) 35.1.126 regulator for hoods as per sample ) ( only labour ) 35.1.127 regulator for hoods in as per sample ) ( composite ) 35.1.128 16 amp, switch with red indicator ( only supply ) 35.1.129 16 amp, switch with red indicator ( only labour ) 35.1.130 16 amp, switch with red indicator ( composite ) 35.1.131 16 amp, switch with red indicator ( only supply ) 35.1.132 16 amp, switch with red indicator ( only labour ) 35.1.133 16 amp, switch with red indicator ( composiet ) 35.1.134 carbon brush for mixers etc. ( all sizes ) ( only supply ) 35.1.135 carbon brush for mixers etc. ( all sizes ) ( only labour ) 35.1.136 carbon brush for mixers etc. ( all sizes ) ( composite ) 35.1.137 carbon brush used for special purpose m / c ( only supply ) 35.1.138 carbon brush used for special purpose m / c ( only labour ) 35.1.139 carbon brush used for special purpose m / c ( composite ) 35.2 modular accesseries for anchor roma , legrand , as per existing at site matching or equivalent. general guidelines are as per item no 35.1 35.2.1 6 amp, switch ( only supply ) 35.2.2 6 amp, switch ( only labour ) 35.2.3 6 amp, switch ( composite ) 35.2.4 16 amp, switch ( only supply ) 35.2.5 16 amp, switch ( only labour ) 35.2.6 16 amp, switch ( composite ) 35.2.7 6 amp, two way switch ( only supply ) 35.2.8 6 amp, two way switch ( only labour ) 35.2.9 6 amp, two way switch ( composite ) 35.2.10 10 / 16 amp , two –way switch ( only supply ) 35.2.11 10 / 16 amp , two –way switch ( only labour ) 35.2.12 10 / 16 amp , two –way switch ( composite ) 35.2.13 6 amp, socket ( only supply ) 35.2.14 6 amp, socket ( only labour ) 35.2.15 6 amp, socket ( composite ) 35.2.16 16 amp, 3 pin socket ( only supply ) 35.2.17 16 amp, 3 pin socket ( only labour ) 35.2.18 16 amp, 3 pin socket ( compoxite ) 35.2.19 16 amp, 5 pin socket ( only supply ) 35.2.20 16 amp, 5 pin socket ( only labour ) 35.2.21 16 amp, 5 pin socket ( composite ) 35.2.22 telephone socket ( rj 11 ) ( only supply ) 35.2.23 telephone socket ( rj 11 ) ( only labour ) 35.2.24 telephone socket ( rj 11 ) ( composite ) 35.2.25 fan dimmer , 400 / 600w ( 0nly supply ) 35.2.26 fan dimmer, 400 / 600w ( 0nly labour ) 35.2.27 fan dimmer, 400 / 600w ( composite ) 35.2.28 1 way tv socket ( only supply ) 35.2.29 1 way tv socket ( only labour ) 35.2.30 1 way tv socket ( composite ) 35.2.31 2 way tv socket ( only supply ) 35.2.32 2 way tv socket ( only labour. ) 35.2.33 2 way tv socket ( composite ) 35.2.34 6 amp, switch with indicator ( only supply ) 35.2.35 6 amp, switch with indicator ( only labour ) 35.2.36 6 amp, switch with indicator ( composite ) 35.2.37 bell push ( only supply ) 35.2.38 bell push ( only labour ) 35.2.39 bell push ( composite ) 35.2.40 fan dimmer , 1000w ( 0nly supply ) 35.2.41 fan dimmer, 1000w ( 0nly labour ) 35.2.42 fan dimmer, 1000w ( composite ) 35.2.43 blank plate ( 0nly supply ) 35.2.44 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly supply ) 35.2.45 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly labour ) 35.2.46 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( composite ) 35.2.47 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly supply ) 35.2.48 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly labour ) 35.2.49 16 to 32a dp mcb with modular box including face plate surface / conealed type ( composite ) 35.2.50 rj 45 data socket ( 0nly supply ) 35.2.51 rj 45 data socket ( 0nly labour ) 35.2.52 rj 45 data socket ( composite ) 35.3 surface ( pvc ) boxes for modular accessories 35.3.1 1 or 2 way ( only supply ) 35.3.2 1 or 2 way ( only labour ) 35.3.3 1 or 2 way ( composite ) 35.3.4 3 way ( only supply ) 35.3.5 3 way ( only labour ) 35.3.6 3 way ( composite ) 35.3.7 4 way ( only supply ) 35.3.8 4 way ( only labour ) 35.3.9 4 way ( composite ) 35.3.10 6 way ( only supply ) 35.3.11 6 way ( only labour ) 35.3.12 6 way ( composite ) 35.3.13 8 way ( only supply ) 35.3.14 8 way ( only labour ) 35.3.15 8 way ( composite ) 35.3.16 8 way vertical / rectangular ( only supply ) 35.3.17 8 way vertical / rectangular ( only labour ) 35.3.18 8 way vertical / rectangular ( composite ) 35.3.19 12 way ( only supply ) 35.3.20 12 way ( only labour ) 35.3.21 12 way ( composite ) 35.3.22 16 way ( only supply ) 35.3.23 16 way ( only labour ) 35.3.24 16 way ( composite ) 35.3.25 18 way ( only supply ) 35.3.26 18 way ( only labour ) 35.3.27 18 way ( composite ) 35.4 concealed ( ms ) boxes for modular accessories & general accessories 35.4.1 1 or 2 way ( only supply ) 35.4.2 1 or 2 way ( only labour ) 35.4.3 1 or 2 way ( composite ) 35.4.4 3 way ( only supply ) 35.4.5 3 way ( only labour ) 35.4.6 3 way ( composite ) 35.4.7 4 way ( only supply ) 35.4.8 4 way ( only labour ) 35.4.9 4 way ( composite ) 35.4.10 6 way ( only supply ) 35.4.11 6 way ( only labour ) 35.4.12 6 way ( composite ) 35.4.13 8 way ( only supply ) 35.4.14 8 way ( only labour ) 35.4.15 8 way ( composite ) 35.4.16 8 way vertical / rectangular ( only supply ) 35.4.17 8 way vertical / rectangular ( only labour ) 35.4.18 8 way vertical / rectangular ( composite ) 35.4.19 12 way ( only supply ) 35.4.20 12 way ( only labour ) 35.4.21 12 way ( composite ) 35.4.22 16 way ( only supply ) 35.4.23 16 way ( only labour ) 35.4.24 16 way ( composite ) 35.4.25 18 way ( only supply ) 35.4.26 18 way ( only labour ) 35.4.27 18 way ( composite ) 35.5 face plate for modular accessories 35.5.1 1 way ( only supply ) 35.5.2 1 way ( only labour ) 35.5.3 1 way ( composite ) 35.5.4 2 way ( only supply ) 35.5.5 2 way ( only labour ) 35.5.6 2 way ( composite ) 35.5.7 3 way ( only supply ) 35.5.8 3 way ( only labour ) 35.5.9 3 way ( composite ) 35.5.10 4 way ( only supply ) 35.5.11 4 way ( only labour ) 35.5.12 4 way ( composite ) 35.5.13 6 way ( only supply ) 35.5.14 6 way ( only labour ) 35.5.15 6 way ( composite ) 35.5.16 8 way ( only supply ) 35.5.17 8 way ( only labour ) 35.5.18 8 way ( composite ) 35.5.19 8 way vertical / rectangular ( only supply ) 35.5.20 8 way vertical / rectangular ( only labour ) 35.5.21 8 way vertical / rectangular ( composite ) 35.5.22 12 way ( only supply ) 35.5.23 12 way ( only labour ) 35.5.24 12 way ( composite ) 35.5.25 16 way with or with indicator ( only supply ) 35.5.26 16 way with or with indicator ( only labour ) 35.5.27 16 way with or with indicator ( composite ) 35.5.28 18 way ( only supply ) 35.5.29 18 way ( only labour ) 35.5.30 18 way ( composite ) 35.5.31 cord less bell ( only supply ) 35.6 mcb fixing channel ( only supply ) 35.6.1 mcb fixing channel ( only labour ) 35.6.2 mcb fixing channel ( composite ) 35.7 connector fixing channel ( cst channel ) ( only supply ) 35.7.1 connector fixing channel ( cst channel ) ( only labour ) 35.7.2 connector fixing channel ( cst channel ) ( composite ) 35.8 ht electrical tape ( strippex ) , 25 mm x .76 mm x 9.1 m , one roll, make stanvac ( only supply ) 35.9 supply / fixing of assorted accessories 35.9.1 6 amps, 3 pin multi plug connector ( only supply ) 35.9.2 6 amps, 3 pin multi plug connector ( only labour ) 35.9.3 6 amps, 3 pin multi plug connector ( composite ) 35.9.4 16 amps, multi plug connector ( only supply ) 35.9.5 16 amps, multi plug connector ( only labour ) 35.9.6 16 amps, multi plug connector ( composote ) 35.9.7 6a, supper adaptor pearl ( only supply ) 35.9.8 6a, supper adaptor pearl ( only labour ) 35.9.9 6a, supper adaptor pearl ( composite ) 35.9.10 1 way bed switch ( only supply ) 35.9.11 1 way bed switch ( only labour ) 35.9.12 1 way bed switch ( composite ) 35.9.13 adaptor ( only supply ) 35.9.14 adaptor ( only labour ) 35.9.15 adaptor ( composite ) 35.9.16 3 pin flexi cord 6 a, ( extension board ) ( only supply ) 35.9.17 16 a, flexi cord, ( extension board ) ( only supply ) 35.10.a supply / fixing of various gang boxes: 35.10.1 1 way ( only supply ) 35.10.2 1 way ( only labour ) 35.10.3 1 way ( composite ) 35.10.4 2 way ( only supply ) 35.10.5 2 way ( only labour ) 35.10.6 2 way ( composite ) 35.10.7 3 way ( only supply ) 35.10.8 3 way ( only labour ) 35.10.9 3 way ( composite ) 35.10.10 4 way ( only supply ) 35.10.11 4 way ( only labour ) 35.10.12 4 way ( composite ) 35.10.13 5 way ( only supply ) 35.10.14 5 way ( only labour ) 35.10.15 5 way ( composite ) 35.11 supply / fixing of various domestic gang boxes: 35.11.1 1 way ( only supply ) 35.11.2 1 way ( only labour ) 35.11.3 1 way ( composite ) 35.11.4 2 way ( only supply ) 35.11.5 2 way ( only labour ) 35.11.6 2 way ( composite ) 35.11.7 3 way ( only supply ) 35.11.8 3 way ( only labour ) 35.11.9 3 way ( composite ) 35.11.10 4 way ( only supply ) 35.11.11 4 way ( only labour ) 35.11.12 4 way ( composite ) 35.11.13 double domestic ( only supply ) 35.11.14 double domestic ( only labour ) 35.11.15 double domestic ( composite ) 35.11.16 water proof jb for mk switch ( to be used in icu ) ( only supply ) 35.11.17 water proof jb for mk switch ( to be used in icu ) ( only labour ) 35.11.18 water proof jb for mk switch ( to be used in icu ) ( composite ) 35.11.19 legrand make modular type door key switch with key fob ( only supply ) 35.11.20 legrand make modular type door key switch with key fob ( only labour ) 35.11.21 legrand make modular type door key switch with key fob ( composite ) 35.11.22 10a modular switch legrand ( only supply ) 35.11.23 10a modular switch legrand ( only labour ) 35.11.24 10a modular switch legrand ( composite ) 35.11.25 10a modular socket legrand ( only supply ) 35.11.26 10a modular socket legrand ( only labour ) 35.11.27 10a modular socket legrand ( composite ) 35.11.28 20a modular switch legrand ( only supply ) 35.11.29 20a modular switch legrand ( only labour ) 35.11.30 20a modular switch legrand ( composite ) 35.11.31 20a modular socket legrand ( only supply ) 35.11.32 20a modular socket legrand ( only labour ) 35.11.33 20a modular socket legrand ( composite ) 36.1 supplying & replacing the following spare of electrical motor starter controls etc. or whereever applicable with coil voltage 240 v / 440 v.all as per instructions and as directed by e i c, es. old items shall be returned to e i c, es as it is.air brake contactors 36.1.1 air brake contactor l & t make type ml1 or equivalent ( only supply ) 36.1.2 air brake contactor l & t make type ml1 or equivalent ( only labour ) 36.1.3 air brake contactor l & t make type ml1 or equivalent ( composite ) 36.1.4 ml 1.5 or equivalent ( only supply ) 36.1.5 ml 1.5 or equivalent ( only labour ) 36.1.6 ml 1.5 or equivalent ( composite ) 36.1.7 ml 2 or equivalent ( only supply ) 36.1.8 ml 2 or equivalent ( only labour ) 36.1.9 ml 2 or equivalent ( composite ) 36.1.10 ml 3 or equivalent ( only supply ) 36.1.11 ml 3 or equivalent ( only labour ) 36.1.12 ml 3 or equivalent ( composite ) 36.1.13 ml 4 or equivalent ( only supply ) 36.1.14 ml 4 or equivalent ( only labour ) 36.1.15 ml 4 or equivalent ( composite ) 36.1.16 ml 6 or equivalent ( only supply ) 36.1.17 ml 6 or equivalent ( only labour ) 36.1.18 ml 6 or equivalent ( composite ) 36.1.19 ml 10 or equivalent ( only supply ) 36.1.20 ml 10 or equivalent ( only labour ) 36.1.21 ml 10 or equivalent ( composite ) 36.1.22 ml 12 or equivalent ( only supply ) 36.1.23 ml 12 or equivalent ( only labour ) 36.1.24 ml 12 or equivalent ( composite ) 36.2 supply & replacement of following spare parts, kit for l & t or equivalent make power contactor. work is to be carried out as per instructions ans as per direction of e i c, es. old / remob ved items shall be returned to e i c, es as it is. 36.2.1 ml 1 or equivalent ( only supply ) 36.2.2 ml 1 or equivalent ( only labour ) 36.2.3 ml 1 or equivalent ( composite ) 36.2.4 ml 1.5 or equivalent ( only supply ) 36.2.5 ml 1.5 or equivalent ( only labour ) 36.2.6 ml 1.5 or equivalent ( composite ) 36.2.7 ml 2 or equivalent ( only supply ) 36.2.8 ml 2 or equivalent ( only labour ) 36.2.9 ml 2 or equivalent ( composite ) 36.2.10 ml 3 or equivalent ( only supply ) 36.2.11 ml 3 or equivalent ( only labour ) 36.2.12 ml 3 or equivalent ( composite ) 36.2.13 ml 4 or equivalent ( only supply ) 36.2.14 ml 4 or equivalent ( only labour ) 36.2.15 ml 4 or equivalent ( composite ) 36.2.16 ml 6 or equivalent ( only supply ) 36.2.17 ml 6 or equivalent ( only labour ) 36.2.18 ml 6 or equivalent ( composite ) 36.2.19 ml 10 or equivalent ( only supply ) 36.2.20 ml 10 or equivalent ( only labour ) 36.2.21 ml 10 or equivalent ( composite ) 36.2.22 ml 12 or equivalent ( only supply ) 36.2.23 ml 12 or equivalent ( only labour ) 36.2.24 ml 12 or equivalent ( composite ) 36.3 supply & fixing of hrc fuses as per instructions and as directed by e i c, es. old / removed item shall be returned to e i c, es. 36.3.1 1a to 6a ( only supply ) 36.3.2 1a to 6a ( only labour ) 36.3.3 1a to 6a ( composite ) 36.3.4 16a ( only supply ) 36.3.5 16a ( only labour ) 36.3.6 16a ( composite ) 36.3.7 32a ( only supply ) 36.3.8 32a ( only labour ) 36.3.9 32a ( composite ) 36.3.10 63a ( only supply ) 36.3.11 63a ( only labour ) 36.3.12 63a ( composite ) 36.3.13 100a ( only supply ) 36.3.14 100a ( only labour ) 36.3.15 100a ( composite ) 36.3.16 125a ( only supply ) 36.3.17 125a ( only labour ) 36.3.18 125a ( composite ) 36.3.19 160a ( only supply ) 36.3.20 160a ( only labour ) 36.3.21 160a ( composite ) 36.3.22 250a ( only supply ) 36.3.23 250a ( only labour ) 36.3.24 250a ( composite ) 36.3.25 315a ( only supply ) 36.3.26 315a ( only labour ) 36.3.27 315a ( composite ) 36.3.28 400a ( only supply ) 36.3.29 400a ( only labour ) 36.3.30 400a ( composite ) 36.3.31 630a ( only supply ) 36.3.32 630a ( only labour ) 36.3.33 630a ( composite ) 36.3.34 800 a ( only supply ) 36.3.35 800 a ( only labour ) 36.3.36 800 a ( composite ) 36.4 replacement of the following item make bakelite cut out complete fuse holder db mounted, all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.4.1 16 a ( only supply ) 36.4.2 16 a ( only labour ) 36.4.3 16 a ( composite ) 36.4.4 32 a ( only supply ) 36.4.5 32 a ( only labour ) 36.4.6 32 a ( composite ) 36.4.7 63 a ( only supply ) 36.4.8 63 a ( only labour ) 36.4.9 63 a ( composite ) 36.5 replacement of the kit kat fuse all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.5.1 1a delay fuse ( only supply ) 36.5.2 1.5 a delay fuse ( only supply ) 36.5.3 5 amps ( only supply ) 36.5.4 5 amps ( only labour ) 36.5.5 5 amps ( composite ) 36.5.6 10 amps ( only supply ) 36.5.7 10 amps ( only labour ) 36.5.8 10 amps ( composite ) 36.5.9 15 amps ( only supply ) 36.5.10 15 amps ( only labour ) 36.5.11 15 amps ( composite ) 36.6 replacement of the porcelain fuse ( base +top ) all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.6.1 5 amps ( only supply ) 36.6.2 5 amps ( only labour ) 36.6.3 5 amps ( composite ) 36.6.4 10 amps ( only supply ) 36.6.5 10 amps ( only labour ) 36.6.6 10 amps ( composite ) 36.6.7 25 amps ( only supply ) 36.6.8 25 amps ( only labour ) 36.6.9 25 amps ( composite ) 36.6.10 32 amps ( only supply ) 36.6.11 32 amps ( only labour ) 36.6.12 32 amps ( composite ) 36.7 replacement of the neutral link all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.7.1 16 a ( only supply ) 36.7.2 16 a ( only labour ) 36.7.3 16 a ( composite ) 36.7.4 32 a ( only supply ) 36.7.5 32 a ( only labour ) 36.7.6 32 a ( composite ) 36.7.7 63 a ( only supply ) 36.7.8 63 a ( only labour ) 36.7.9 63 a ( composite ) 36.8 replacement of elmex / connectwell connector block suitable for following cable sizes & reconnection of vided leads, all as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.8.1 1.5 sq. mm ( only supply ) 36.8.2 1.5 sq. mm ( only labour ) 36.8.3 1.5 sq. mm ( composite ) 36.8.4 2.5 sq. mm ( only supply ) 36.8.5 2.5 sq. mm ( only labour ) 36.8.6 2.5 sq. mm ( composite ) 36.8.7 4 sq. mm ( only supply ) 36.8.8 4 sq. mm ( only labour ) 36.8.9 4 sq. mm ( composite ) 36.8.10 6 sq. mm ( only supply ) 36.8.11 6 sq. mm ( only labour ) 36.8.12 6 sq. mm ( composite ) 36.8.13 10 sq. mm ( only supply ) 36.8.14 10 sq. mm ( only labour ) 36.8.15 10 sq. mm ( composite ) 36.8.16 16 sq. mm ( only supply ) 36.8.17 16 sq. mm ( only labour ) 36.8.18 16 sq. mm ( composite ) 36.8.19 25 sq. mm ( only supply ) 36.8.20 25 sq. mm ( only labour ) 36.8.21 25 sq. mm ( composite ) 36.8.22 35 sq. mm ( only supply ) 36.8.23 35 sq. mm ( only labour ) 36.8.24 35 sq. mm ( composite ) 36.8.25 50 sq. mm ( only supply ) 36.8.26 50 sq. mm ( only labour ) 36.8.27 50 sq. mm ( composite ) 36.8.28 70 sq. mm ( only supply ) 36.8.29 70 sq. mm ( only labour ) 36.8.30 70 sq. mm ( composite ) 36.8.31 95 sq. mm ( only supply ) 36.8.32 95 sq. mm ( only labour ) 36.8.33 95 sq. mm ( composite ) 36.8.34 120 sq. mm ( only supply ) 36.8.35 120 sq. mm ( only labour ) 36.8.36 120 sq. mm ( composite ) 36.8.37 ct shorting terminals ( only supply ) 36.8.38 ct shorting terminals ( only labour ) 36.8.39 ct shorting terminals ( composite ) 36.9 supply / replacement of terminal strips / blocks for varios types of motors etc as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.9.1 motors up to 10 hp ( only supply ) 36.9.2 motors up to 10 hp ( only labour ) 36.9.3 motors up to 10 hp ( composite ) 36.9.4 motors up to 20 hp ( only supply ) 36.9.5 motors up to 20 hp ( only labour ) 36.9.6 motors up to 20 hp ( composite ) 36.9.7 motors up to 30 hp ( only supply ) 36.9.8 motors up to 30 hp ( only labour ) 36.9.9 motors up to 30 hp ( composite ) 36.9.10 motors up to 40 hp ( only supply ) 36.9.11 motors up to 40 hp ( only labour ) 36.9.12 motors up to 40 hp ( composite ) 36.9.13 motors up to 50 hp ( only supply ) 36.9.14 motors up to 50 hp ( only labour ) 36.9.15 motors up to 50 hp ( composite ) 36.9.16 motors up to 60 hp ( only supply ) 36.9.17 motors up to 60 hp ( only labour ) 36.9.18 motors up to 60 hp ( composite ) 37.1 .ms sheet for boxes etc ms sheet for 16 swg to be used for fabrication of boxes, panels, cable and boxes etc. including cutting, bending, drilling, welding, riveting etc & painting with red oxide lead paint & two coats of enamel paint all as per instructions and as directed by e i c, es. 37.1.1 as per item no 37.1 for 14 swg ( only supply ) 37.1.2 as per item no 37.1 for 14 swg ( only labour ) 37.1.3 as per item no 37.1 for 14 swg ( composite ) 37.1.4 as per item no 37.1 for but for 16 swg ( only supply ) 37.1.5 as per item no 37.1 for but for 16 swg ( only labour ) 37.1.6 sas per item no 37.1 for but for 16 swg ( composite ) 37.1.7 as per item no 37.1 for but for 18 swg ( only supply ) 37.1.8 as per item no 37.1 for but for 18 swg ( only labour ) 37.1.9 as per item no 37.1 for but for 18 swg ( composite ) 37.2 supply, fabrication & installation of ms angle / strip / plate / rod / channel etc. as per given design duly painted with 2 coats of red oxide & 2 coats of enamel paint of approved shade all as per the instruction of eic. ( composite ) 37.3 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.3.1 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.3.2 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.4 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.4.1 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.4.2 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.5 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only supply ) 37.5.1 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only labour ) 37.5.2 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( composite ) 38.1 timers for starters / preventers supply, fixing & testing of on delay timer 0 to 60 sec. ( only supply ) 38.2 supply, fixing & testing of on delay timer 0 to 60 sec. ( only labour ) 38.3 supply, fixing & testing of on delay timer 0 to 60 sec. ( composite ) 38.4 supply, fixing & testing of off delay timer ( only supply ) 38.5 supply, fixing & testing of off delay timer ( only labour ) 38.6 supply, fixing & testing of off delay timer ( composite ) 38.7 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( only supply ) 38.8 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 38.9 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( composite ) 39 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.1 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.2 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( composite ) 39.3 single phase preventer type mpr1 ( only supply ) 39.4 single phase preventer type mpr1 ( only labour ) 39.5 single phase preventer type mpr1 ( composite ) 39.6 supply, fixing & testing of 0 24 hrs set digital timer ( only supply ) 39.7 supply, fixing & testing of 0 24 hrs set digital timer ( only labour ) 39.8 supply, fixing & testing of 0 24 hrs set digital timer ( composit ) 40.1 supply, installation & testing of app type capacitors / apfc relays, 440 v, 50 hz, all as per instructions ans as directed by e i c, es old / removed items shall be returned to e i c, es as it is. 25 kvar ( only supply ) 40.2 25 kvar ( only labour ) 40.3 25 kvar ( composite ) 40.4 50 kvar ( only supply ) 40.5 50 kvar ( only labour ) 40.6 50 kvar ( composite ) 40.7 100 kvar ( only supply ) 40.8 100 kvar ( only labour ) 40.9 100 kvar ( composite ) 40.10.a supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only supply ) 40.11 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only labour ) 40.12 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( composite ) 40.13 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only supply ) 40.14 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only labour ) 40.15 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( composite ) 41.1 fittings & fixtures supply / replacement, installation, testing & commissioning of following various fixtures & fittings complete with fluorescent tube / incandescent lamp / pl s lamp or any other suitale lamp etc. on surface of slab / beam / wall by means of brackets made out of 25 x 3 mm strip & 2 nos. of 6 mm anchor fastener / suspended from slab / beam by means of 19 mm dia. conduit pipe, ball & socket arrangement flexible 2 core 40 / 30 size cable / wire connection etc.or by means of suitable fixing arrangement, complete in all respect & as per instruction of engg. in charge & with prior approval by presenting sample fitting. make:philips / crompton / ge / wipro / orient or equivalent. in case of replacement old / removed items shall be reuturned to e i c, es as it is. 1 x 40 w rail ( box ) type fluorescent fitting ( only supply ) 41.2 1 x 40 w rail ( box ) type fluorescent fitting ( only labour ) 41.3 1 x 40 w rail ( box ) type fluorescent fitting ( composite ) 41.4 2 x 40 w rail type fluorescent ( only supply ) 41.5 2 x 40 w rail type fluorescent ( only labour ) 41.6 2 x 40 w rail type fluorescent ( composite ) 41.7 2 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.8 2 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.9 2 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.10.a 1 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.11 1 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.12.a 1 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.13 2 x 40 w industrial type fluorescent fitting ( only supply ) 41.14 2 x 40 w industrial type fluorescent fitting ( only labour ) 41.15 2 x 40 w industrial type fluorescent fitting ( composite ) 41.16 2 x 9 w pl s decorative recess type fitting. ( only supply ) 41.17.a 2 x 9 w pl s decorative recess type fitting. ( only labour ) 41.18 2 x 9 w pl s decorative recess type fitting. ( composite ) 41.19 2 x 11 w decorative surface type fitting ( only supply ) 41.20.a 2 x 11 w decorative surface type fitting ( only labour ) 41.21 2 x 11 w decorative surface type fitting ( composite ) 41.22 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only supply ) 41.23 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only labour ) 41.24 1 x 40 w decorative mirror optic fluorescent fitting surface type ( composite ) 41.25 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only supply ) 41.26 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only labour ) 41.27 2 x 40 w decorative mirror optic fluoresce fitting surface type ( composite ) 41.28 bulkhead fitting suitable for pl – s 9 w lamp ( only supply ) 41.29 bulkhead fitting suitable for pl – s 9 w lamp ( only labour ) 41.30.a bulkhead fitting suitable for pl – s 9 w lamp ( composite ) 41.31 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only supply ) 41.32 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only labour ) 41.33 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( composite ) 41.34 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.35 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.36 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.37 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.38 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.39 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.40.a 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only supply ) 41.41 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only labour ) 41.42 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( composite ) 41.43 decorative incandescent fixtures for red indication lamp ( only supply ) 41.44 decorative incandescent fixtures for red indication lamp ( only labour ) 41.45 decorative incandescent fixtures for red indication lamp ( composite ) 41.46 decorative incandescent fixtures with 75 w comptalux lamp ( only supply ) 41.47 decorative incandescent fixtures with 75 w comptalux lamp ( only labour ) 41.48 decorative incandescent fixtures with 75 w comptalux lamp ( composite ) 41.49 decorative incandescent fixtures for lecture hall [ 100w ] ( ( only supply ) 41.50.a decorative incandescent fixtures for lecture hall [ 100w ] ( ( only labour ) 41.51 decorative incandescent fixtures for lecture hall [ 100w ] ( ( composite ) 41.52 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only supply ) 41.53 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only labour ) 41.54 1 x 9 w decorative wall mounted fixtures with electronic ballast ( composite ) 41.55 2 x 9 w decorative fixtures for ( entrance canopy ) ( only supply ) 41.56 2 x 9 w decorative fixtures for ( entrance canopy ) ( only labour ) 41.57 2 x 9 w decorative fixtures for ( entrance canopy ) ( composite ) 41.58 2 x 25 w exit light fixture ( only supply ) 41.59 2 x 25 w exit light fixture ( only labour ) 41.60.a 2 x 25 w exit light fixture ( composite ) 41.61 2 x 18 w fluorescent industrial fitting for fume hood ( only supply ) 41.62 2 x 18 w fluorescent industrial fitting for fume hood ( only labour ) 41.63 2 x 18 w fluorescent industrial fitting for fume hood ( composite ) 41.64 1 x 9 w decorative surface fitting for wash basin mirror ( only supply ) 41.65 1 x 9 w decorative surface fitting for wash basin mirror ( only labour ) 41.66 1 x 9 w decorative surface fitting for wash basin mirror ( composite ) 41.67 night lamp fixture 15 w ( only supply ) 41.68 night lamp fixture 15 w ( only labour ) 41.69 night lamp fixture 15 w ( composite ) 41.70.a halogen lamp fitting. 41.70.1 suitable for 500 w ( only supply ) 41.70.2 suitable for 500 w ( only labour ) 41.70.3 suitable for 500 w ( composite ) 41.70.4 suitable for 1000 w ( only supply ) 41.70.5 suitable for 1000 w ( only labour ) 41.70.6 suitable for 1000 w ( composite ) 41.71 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only supply ) 41.72 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only labour ) 41.73 decorative incandescent fixture with 60 w / 75 w reflector lamp ( composite ) 41.74 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only supply ) 41.75 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only labour ) 41.76 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( composite ) 41.77 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only supply ) 41.78 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only labour ) 41.79 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( composite ) 41.80.a recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only supply ) 41.81 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only labour ) 41.82 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( composite ) 41.83 floor washer ( only supply ) 41.84 floor washer ( only labour ) 41.85 floor washer ( composite ) 41.86 turbolite with 6 cell reflector ( only supply ) 41.87 turbolite with 6 cell reflector ( only labour ) 41.88 turbolite with 6 cell reflector ( composite ) 41.89 solaris down lighter ( only supply ) 41.90.a solaris down lighter ( only labour ) 41.91 solaris down lighter ( composite ) 41.92 moisture proof halogen recessed fixture ( only supply ) 41.93 moisture proof halogen recessed fixture ( only labour ) 41.94 moisture proof halogen recessed fixture ( composite ) 41.95 gemini baflux max 2x 18 w plc lamp ( only supply ) 41.96 gemini baflux max 2x 18 w plc lamp ( only labour ) 41.97 gemini baflux max 2x 18 w plc lamp ( composite ) 41.98 rivia mini with 1 plc 10w ( only supply ) 41.99 rivia mini with 1 plc 10w ( only labour ) 41.100.a rivia mini with 1 plc 10w ( composite ) 41.101 emergency tube light fixture suitable to fix 9w pl lamp, ( only supply ) 41.102 emergency tube light fixture suitable to fix 9w pl lamp, ( only labour ) 41.103 emergency tube light fixture suitable to fix 9w pl lamp, ( composite ) 41.104 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only supply ) 41.105 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only labour ) 41.106 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( composite ) 41.107 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only supply ) 41.108 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only labour ) 41.109 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( composite ) 41.110.a dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only supply ) 41.111 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only labour ) 41.112 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( composite ) 41.113 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only supply ) 41.114 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only labour ) 41.115 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( composite ) 41.116 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.117 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.118 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.119 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.120.a fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.121 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.122 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only supply ) 41.123 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only labour ) 41.124 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( composite ) 41.125 2 x 36w pll fixture ( only supply ) 41.126 2 x 36w pll fixture ( only labour ) 41.127 2 x 36w pll fixture ( composite ) 41.128 25w, plc, lighting fixture ( only supply ) 41.129 25w, plc, lighting fixture ( only labour ) 41.130.a 25w, plc, lighting fixture ( composite ) 41.131 1x28w, energy efficient box type fitting ( only supply ) 41.132 1x28w, energy efficient box type fitting ( only labour ) 41.133 1x28w, energy efficient box type fitting ( composite ) 41.134 25w, plc lighting fixture ( only supply ) 41.135 25w, plc lighting fixture ( only labour ) 41.136 25w, plc lighting fixture ( composite ) 41.137 led light fixtures 6w recessed mounted led lighting fixture ( only supply ) 41.138 6w recessed mounted led lighting fixture ( only labour ) 41.139 6w recessed mounted led lighting fixture ( composite ) 41.140.a 9w recessed mounted led lighting fixture ( only supply ) 41.141 9w recessed mounted led lighting fixture ( only labour ) 41.142 9w recessed mounted led lighting fixture ( composite ) 41.143 12w recessed mounted led lighting fixture ( only supply ) 41.144 12w recessed mounted led lighting fixture ( only labour ) 41.145 12w recessed mounted led lighting fixture ( composite ) 41.146 15w recessed mounted led lighting fixture ( only supply ) 41.147 15w recessed mounted led lighting fixture ( only labour ) 41.148 15w recessed mounted led lighting fixture ( composite ) 41.149 18w recessed mounted led lighting fixture ( only supply ) 41.150.a 18w recessed mounted led lighting fixture ( only labour ) 41.151 18w recessed mounted led lighting fixture ( composite ) 41.152 24w recessed mounted led lighting fixture ( only supply ) 41.153 24w recessed mounted led lighting fixture ( only labour ) 41.154 24w recessed mounted led lighting fixture ( composite ) 41.155 3w recessed led type halogen lighting fixture ( only supply ) 41.156 3w recessed led type halogen lighting fixture ( only labour ) 41.157 3w recessed led type halogen lighting fixture ( composite ) 41.158 6w recessed led type halogen lighting fixture ( only supply ) 41.159 6w recessed led type halogen lighting fixture ( only labour ) 41.160.a 6w recessed led type halogen lighting fixture ( composite ) 41.161 9w recessed led type halogen lighting fixture ( only supply ) 41.162 9w recessed led type halogen lighting fixture ( only labour ) 41.163 9w recessed led type halogen lighting fixture ( composite ) 41.164 36w, 2x2 size recessed led lighting fixture ( only supply ) 41.165 36w, 2x2 size recessed led lighting fixture ( only labour ) 41.166 36w, 2x2 size recessed led lighting fixture ( composite ) 41.167 42w, 2x2 size recessed led lighting fixture ( only supply ) 41.168 42w, 2x2 size recessed led lighting fixture ( only labour ) 41.169 42w, 2x2 size recessed led lighting fixture ( composite ) 41.170 32w, 4 long fully diffused recessed led lighting fixture ( only supply ) 41.171 32w, 4 long fully diffused recessed led lighting fixture ( only labour ) 41.172 32w, 4 long fully diffused recessed led lighting fixture ( composite ) 41.173 6w surface mounted led lighting fixture ( only supply ) 41.174 6w surface mounted led lighting fixture ( only labour ) 41.175 6w surface mounted led lighting fixture ( composite ) 41.176 9w surface mounted led lighting fixture ( only supply ) 41.177 9w surface mounted led lighting fixture ( only labour ) 41.178 9w surface mounted led lighting fixture ( composite ) 41.179 12w surface mounted led lighting fixture ( only supply ) 41.180 12w surface mounted led lighting fixture ( only labour ) 41.181 12w surface mounted led lighting fixture ( composite ) 41.182 15w surface mounted led lighting fixture ( only supply ) 41.183 15w surface mounted led lighting fixture ( only labour ) 41.184 15w surface mounted led lighting fixture ( composite ) 41.185 18w surface mounted led lighting fixture ( only supply ) 41.186 18w surface mounted led lighting fixture ( only labour ) 41.187 18w surface mounted led lighting fixture ( composite ) 41.188 24w surface type led lighting fixture ( only supply ) 41.189 24w surface type led lighting fixture ( only labour ) 41.190 24w surface type led lighting fixture ( composite ) 41.191 22w, 4 long surface type led lighting fixture ( only supply ) 41.192 22w, 4 long surface type led lighting fixture ( only labour ) 41.193 22w, 4 long surface type led lighting fixture ( composite ) 41.194 8w, 2 long surface type led lighting fixture ( only supply ) 41.195 8w, 2 long surface type led lighting fixture ( only labour ) 41.196 8w, 2 long surface type led lighting fixture ( composite ) 41.197 32w, 4 long fully diffused surface led lighting fixture ( only supply ) 41.198 32w, 4 long fully diffused surface led lighting fixture ( only labour ) 41.199 32w, 4 long fully diffused surface led lighting fixture ( composite ) 41.200 22w, 4 long led tube ( only supply ) with one year warranty 41.201 22w, 4 long led tube ( only labour ) 41.202 22w, 4 long led tube ( only composite ) 42 providing, fixing & commissioning of ceiling fan white / brown colour as per requirement including down rod, double ball baring etc all as per instructions and as directed by e i c, es. in case of replacement old / removed item shall be returned to e i c, es as it is. 42.1 size 1400 mm sweep ( only supply ) 42.2 size 1400 mm sweep ( only labour ) 42.3 size 1400 mm sweep ( composite ) 42.4 size 1200 mm sweep ( only supply ) 42.5 size 1200 mm sweep ( only labour ) 42.6 size 1200 mm sweep ( composite ) 42.7 size 900 mm sweep ( only supply ) 42.8 size 900 mm sweep ( only labour ) 42.9 size 900 mm sweep ( composite ) 42.10.a same as per item no 42 but for wall mounted fan 42.10.1 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only supply ) 42.10.2 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only labour ) 42.10.3 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( composite ) 42.11 same as per item no 42 but for pedestal mounted fan 42.11.1 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.2 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.3 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( composite ) 42.11.4 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.5 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.6 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( composite ) 43 providing & erecting 1 phase or exhaust fan metal body with ms frame & gravity louvers, 1400 rpm, 230 v, 50 hz, all as per instructions and as directed by e i c, es. in case of replacement old / removed items shall be returned to e i c, es. 43.1.a 150 mm ( only supply ) 43.2 150 mm ( only labour ) 43.3 150 mm ( composite ) 43.4 200 mm ( only supply ) 43.5 200 mm ( only labour ) 43.6 200 mm ( composite ) 43.7 225 mm ( only supply ) 43.8 225 mm ( only labour ) 43.9 225 mm ( composite ) 43.10 300 mm ( only supply ) 43.11 300 mm ( only labour ) 43.12 300 mm ( composite ) 43.13 375 mm ( only supply ) 43.14 375 mm ( only labour ) 43.15 375 mm ( composite ) 43.16 450 mm ( only supply ) 43.17 450 mm ( only labour ) 43.18 450 mm ( composite ) street lighting supply / replacement, testing & commissioning of external terminal box of size 200 x 250 x 150 mm made of 4 mm thick cast iron / pvc, neatly painted complete with front operable door with allen key locking arrangement, arrangement for gland entry, water proof gasket, 4 nos. of 8 mm dia. 40 mm long brass terminals on 150 x 30 x 10 mm bakelite strip, 16 a hrc fuse base & carrier with 6 a hrc fuse / 16a sp mcb, 16 a neutral link, nipple or sleeve of external dia. 38 mm which can be inserted in 38 mm dia. gi pipe, all as directed by o i c, es. equvilent arrangement can be done only after prior approval for make as well as other releted fixing / control gear arrangement. in case of replacement old / removed item shall be returned to e i c, es. led street light fitting of following ratings having pressure die cast aluminimum housing with coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint , suitable to following features. luminaires suitable with base plate and fitted on a existing site pole. in built electronic led driver, high transmisivity diffuser>85%, ip 65 / 67 high efficacy, provide uniform low glare lighting , cri 70, warm white operating temperature: 40 to +60 celsius degree operatable voltage 220 240 v, 50 hz, pf>0.9, 44.1.1 70 / 85w cfl lamp fitting ( only supply ) 44.1.2 70 / 85w cfl lamp fitting ( only labour ) 44.1.3 70 / 85w cfl lamp fitting ( composite ) 44.1.4 9 / 11w, 12v, 75 ah solar stree light fitting ( only supply ) 44.1.5 9 / 11w, 12v, 75 ah solar stree light fitting ( only labour ) 44.1.6 9 / 11w, 12v, 75 ah solar stree light fitting ( composite ) 44.1.7 led street lights 20w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.8 20w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.9 20w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.10 25w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.11 25w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.12 25w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.13 35w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.14 35w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.15 35w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.16 60w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.17 60w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.18 60w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.19 70w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.20 70w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.21 70w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.22 90w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.23 90w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.24 90w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.25 120w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.26 120w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.27 120w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.28 20w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.29 20w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.30 20w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.31 30w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.32 30w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.33 30w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.34 50w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.35 50w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.36 50w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.37 80w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.38 80w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.39 80w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.40 100w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.41 100w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.42 100w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.43 120w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.44 120w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.45 120w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.46 150w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.47 150w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.48 150w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.49 200w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.50 200w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.51 200w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.52 30w, led dom light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.53 30w, led dom light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.54 30w, led dom light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.55 led street light drivers20w, led street light driver ( only supply ) 44.1.56 20w, led street light driver ( only labour ) 44.1.57 20w, led street light driver ( composite ) 44.1.58 25w, led street light driver ( only supply ) 44.1.59 25w, led street light driver ( only labour ) 44.1.60 25w, led street light driver ( composite ) 44.1.61 30 / 40w, led street light driver ( only supply ) 44.1.62 30 / 40w, led street light driver ( only labour ) 44.1.63 30 / 40w, led street light driver ( composite ) 44.1.64 60w, led street light driver ( only supply ) 44.1.65 60w, led street light driver ( only labour ) 44.1.66 60w, led street light driver ( composite ) 44.1.67 70w, led street light driver ( only supply ) 44.1.68 70w, led street light driver ( only labour ) 44.1.69 70w, led street light driver ( composite ) 44.1.70 90w, led street light driver ( only supply ) 44.1.71 90w, led street light driver ( only labour ) 44.1.72 90w, led street light driver ( composite ) 44.1.73 120w, led street light driver ( only supply ) 44.1.74 120w, led street light driver ( only labour ) 44.1.75 120w, led street light driver ( composite ) 44.1.76 150w, led street light driver ( only supply ) 44.1.77 150w, led street light driver ( only labour ) 44.1.78 150w, led street light driver ( composite ) 44.1.79 200w, led street light driver ( only supply ) 44.1.80 200w, led street light driver ( only labour ) 44.1.81 200w, led street light driver ( composite ) 44.2 street light pole erection 44.2.1 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 44.2.2 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 44.2.3 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable to 4cx16 sqmm size ( composite ) . 44.2.4 same as item no. 44.3.3 but with double arm brackets ( only supply ) . 44.2.5 same as item no. 44.3.3 but with double arm brackets ( only labour ) . 44.2.6 same as item no. 44.3.3 but with double arm brackets ( composite ) . 44.2.7 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . casting of new foundation for 7 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . casting of new foundation for 3 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . lamp holders 44.4 lamp holders 44.4.1 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only supply ) 44.4.2 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only labour ) 44.4.3 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( composite ) 44.6.25 supply & fixing of 70w cfl lamp reputed make ( only supply ) 44.6.26 supply & fixing of 70w cfl lamp reputed make ( only labour ) 44.6.27 supply & fixing of 70w cfl lamp reputed make ( composite ) 44.6.28 supply & fixing of 65w cfl lamp reputed make ( only supply ) 44.6.29 supply & fixing of 65w cfl lamp reputed make ( only labour ) 44.6.30 supply & fixing of 65w cfl lamp reputed make ( composite ) 44.6.31 supply & fixing of 85w cfl lamp reputed make ( only supply ) 44.6.32 supply & fixing of 85w cfl lamp reputed make ( only labour ) 44.6.33 supply & fixing of 85w cfl lamp reputed make ( composite ) 44.6.34 supply & fixing of 35w cfl lamp reputed make ( only supply ) 44.6.35 supply & fixing of 35w cfl lamp reputed make ( only labour ) 44.6.36 supply & fixing of 35w cfl lamp reputed make ( composite ) 45.1 telephone system all general guidelines will be as per any kind of point wiring. telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only supply ) 45.2 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only labour ) 45.3 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( composite ) 45.4 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.5 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.6 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.7 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.8 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.9 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.10.a telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.11 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.12 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.13 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.14 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.15 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( composite ) 45.16 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.17 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.18 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.19 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through provided pvc rigid pipe / casing capping. 45.19.1 1 pair, 0.5 mm gauge ( only supply ) 45.19.2 1 pair, 0.5 mm gauge ( only labour ) 45.19.3 1 pair, 0.5 mm gauge ( composite ) 45.19.4 2 pair, 0.5 mm gauge ( only supply ) 45.19.5 2 pair, 0.5 mm gauge ( only labour ) 45.19.6 2 pair, 0.5 mm gauge ( composite ) 45.19.7 5 pair, 0.5 mm guage ( only supply ) 45.19.8 5 pair, 0.5 mm guage ( only labour ) 45.19.9 5 pair, 0.5 mm guage ( composite ) 45.19.10 providing & installation of analogue telephone instrument 45.19.11 providing testing cord for crone block ( only supply ) 45.19.12 providing crone tool ( only supply ) 45.19.13 replacement of cord for tele. instrument, with rj 11 jack at both ends. ( only supply ) 45.19.14 servicing / repair of telephone instrument ( composite ) 45.19.15 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( only supply ) 45.19.16 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( labour ) 45.19.17 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( composite ) 45.19.18 providing & installation of cordless telephone instrument 45.19.19 providing & installation of caller id telephone instrument 45.19.23 supply of camera equivalent 1.3mp / 2mp ip ir dome camera 45.19.24 supply of camera ( 2mp ) ip ir bullet camera 45.19.27 camera turbo hd720p or equivalent , indoor ir turret 1.0 megapixel analogue camera 45.19.28 supply of crimping tool 3 in 1 modular crimping tool, rj45, rj11 cat5e / cat6 lan cutter with cable cutter 45.19.29 sitc of 8 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.30 sitc of 16 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.31 sitc of 24 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.32 supply of 8 port normal switch or equivalent 45.19.33 supply of cat 6 patch cord 01 mtr 45.19.34 supply of cat 6 patch cord 03 mtr 46.1 battery system supply, installation, testing & commissioning of 2 volt batteries suitable 150 ah lead acid battery set and buy back of old battery ( only supply ) 46.2 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.3 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.4 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only supply ) 46.5 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.6 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.7 supply, installation, testing & commissioning of 12 volt smf batteries . ( only supply ) 46.8 supply, installation, testing & commissioning of 12 volt smf batteries . ( only labour ) 46.9 supply, installation, testing & commissioning of 12 volt smf batteries . ( composite ) 46.10.a supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( only supply ) 46.11 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups.. ( only labour ) 46.12 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( composite ) 46.13 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( supply ) 46.14 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( labour ) 46.15 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( composite ) 46.16 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.17 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.18 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg setand buy back of old battery ( composite ) 46.19 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only supply ) 46.20 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only labour ) 46.21 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( composite ) 46.22 distilled water for batteries ( lt. ) ( only supply ) 46.23 battery solution ( litre ) ( only supply ) 46.24 petroleum jelly ( kg ) ( only supply ) 46.25 castrol make ap 3 ball bearing grease ( only supply ) 46.26 battery cell tester, 2 v dc ( only supply ) 46.27 battery for emergency tube light ( only supply ) 46.28 hydrometer for battery solution checking ( only supply ) 46.29 rechargeable battery, 9 v ( for mike etc ) ( only supply ) 46.30.a rechargeable battery, 1.5 v ( only supply ) 46.31 pencil cell for a / c remote ( only supply ) 46.32 pencil cell for cordless bell ( only supply ) 46.33 pencil cell for urinal sensor, clock and general use ( only supply ) 46.34 charger for rechargeable batteries of best quality ( only supply ) 46.35 crc / ctc etc. for general maintenance ( only supply ) 46.36 steelgrip pvc insulation tape ( only supply ) 46.37 cutter machine blade ( only supply ) 46.38 supply of battery connetion cords / leads having lsuitable lug / clamp at the end etc with size of core / wire to connect the battery to ups / chargers etc. all as per instructions of ( only supply ) 46.39 supply of 12 v / 6 ah to 10ah range maintenance free / sealed rocket / / amara raja or other equivalent battery suitable for ups. prior approval for make & other specification is required. ( only supply ) 46.40.a supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only supply ) 46.41 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only labour ) 46.42 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( composite ) 46.43 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only supply ) 46.44 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only labour ) 46.45 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( composite ) 46.46 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only supply ) 46.47 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only labour ) 46.48 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( composite ) 46.49 12volt 26ah maintenance free battery ( only supply ) 46.50.a 12volt 26ah maintenance free battery ( only labour ) 46.51 12volt 26ah maintenance free battery ( composite ) 46.52 12volt 42ah maintenance free battery ( only supply ) 46.53 12volt 42ah maintenance free battery ( only labour ) 46.54 12volt 42ah maintenance free battery ( composite ) 46.55 12volt 7ah maintenance free battery ( only supply ) 46.56 12volt 7ah maintenance free battery ( only labour ) 46.57 12volt 7ah maintenance free battery ( composite ) 46.58 12volt 12ah maintenance free battery ( only supply ) 46.59 12volt 12ah maintenance free battery ( only labour ) 46.60.a 12volt 12ah maintenance free battery ( composite ) 46.61 12volt 7.5ah maintenance free battery ( only supply ) 46.62 12volt 7.5ah maintenance free battery ( only labour ) 46.63 12volt 7.5ah maintenance free battery ( composite ) 47.00 the system of wiring shall consist of isi marked single core, pvc insulated, frls, 1100 volt grade, stranded, flexible copper conductor wires as per is : 694 amended upto date. 47.1 copper wires pvc , panel wires for interconnections. 1.5 sq. mm ( only supply ) 47.2 1.5 sq. mm ( only labour ) 47.3 1.5 sq. mm ( composite ) 47.4.a 2.5 sq. mm ( only supply ) 47.5 2.5 sq. mm ( only labour ) 47.6 2.5 sq. mm ( composite ) 47.7 4 sq. mm ( only supply ) 47.8 4 sq. mm ( only labour ) 47.9 4 sq. mm ( composite ) 47.10.a 6 sq. mm ( only supply ) 47.11 6 sq. mm ( only labour ) 47.12 6 sq. mm ( composite ) 47.13 10 sq. mm ( only supply ) 47.14 10 sq. mm ( only labour ) 47.15 10 sq. mm ( composite ) 47.16 16 sq. mm ( only supply ) 47.17 16 sq. mm ( only labour ) 47.18 16 sq. mm ( composite ) 47.19 25 sq. mm ( only supply ) 47.20.a 25 sq. mm ( only labour ) 47.21 25 sq. mm ( composite ) 47.22 35 sq. mm ( only supply ) 47.23 35 sq. mm ( only labour ) 47.24 35 sq. mm ( composite ) 47.25 50 sq. mm ( only supply ) 47.26 50 sq. mm ( only labour ) 47.27 50 sq. mm ( composite ) 47.28 70 sq. mm ( only supply ) 47.29 70 sq. mm ( only labour ) 47.30.a 70 sq. mm ( composite ) 47.30.1 95 sq. mm ( only supply ) 47.30.2 95 sq. mm ( only labour ) 47.30.3 95 sq. mm ( composite ) 47.31 connection wire for strip heaters along with porcelain balls over it etc. ( only supply ) 47.32 connection wire for strip heaters along with porcelain balls over it etc. ( only labour ) 47.33 connection wire for strip heaters along with porcelain balls over it etc. ( composite ) 47.34 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only supply ) ( one pack ) 47.35 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only labuor ) 47.36 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( composite ) 47.37 supply of various kinds / sizes of ms / gi bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.38 supply of various kinds / sizes of brass bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.39 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 6 mm 47.40 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 8 mm 47.41 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 10 mm 47.42 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 12 mm 47.43 supply of verious size of drill bit 47.43.1 drill bit 3 / 16 ms 47.43.2 drill bit 3 / 16 concrete 47.43.3 drill bit 3 / 16 hammering 47.43.4 drill bit 1 / 8 ms 47.43.5 drill bit wooden set 47.43.6 drill bit concrete set 47.43.7 drill bit roraty hammer 4mm 47.43.8 drill bit roraty hammer 8 mm 47.43.9 drill bit roraty hammer 10 mm 47.43.10 drill bit roraty hammer 12 mm 47.43.11 drill machine rotary hammering type 47.43.12 drill pair set mm 47.43.13 drill pair set inches 47.43.14 mini hacksaw blade taparia make 47.43.15 hacksaw blade big size 47.43.16 mini hacksaw blade taparia make with frame 47.43.17 hacksaw blade big size with frame 47.43.18 hole saw cutter ms 16mm to 32mm 47.43.19 hole saw cutter ms 32mm to 75mm 47.43.20 hole saw cutter ms 75mm to 150mm 47.43.21 hole saw cutter ms 150mm to 300mm 47.43.22 pvc grip rawal plastic wall plug per pkt qty 200each 47.43.23 grinding wheel blade 48.1 oil filtration for 2 mva transformer 48.2 oil filtration for 4 / 4.5 mva transformer 48.3 supply & topping up of transformer oil 48.4 yearly servicing for air circuit breakers, 800a , 1000 a / 1250 a / 1600 a / 2000a / 2500a / 3200 a, 440 v, mpact, ge make , abb , sterling existing make , testing of breakers , all type test to be carry out , greasing activity, and complete servicing. 48.5 yearly servicing of circuit breakers 48.5.1 33 kv sf6 circuit breaker 48.5.2 11 kv sf6 circuit breaker 48.5.3 33kv vacuum circuit breaker 48.5.4 11kv vacuum circuit breaker 48.6 testing & calibration of all types of relays, existing makes relays in ht panel, lt panel 48.6.1 cdg 31 / cdag 51 48.6.2 vajh / vajc 48.6.3 vaa / vdg 48.6.4 vtt 48.6.5 vagm / cag / ccum / ycgf / cdv / mfvum 48.6.6 vax 48.6.7 apfc relay 48.6.8 tcs relay ber 2 / ber1 48.6.9 feeder protection relay bcf1 48.6.10 lock out relay 86 48.6.11 restricted earthfault relay 48.6.12 reverse power relay 48.6.13 earthfault relay 48.6.14 calibration of multimeter , clamp meter and megger, earth tester 48.7.1 annual servicing for transformers 2.0 mva 48.7.2 annual servicing for transformers 4.5 / 4.0 mva 48.8 cable fault detecting / fault finding for all sizes of cables. 48.9 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only supply ) 48.10.a supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only labour ) 48.11 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( composite ) 48.12 testing & calibration of all types of energy meter 48.13 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only supply ) 48.14 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only labour ) 48.15 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( composite ) 48.16 providing pair of duly tested rubber hand glows suitable for working on 33kv supply ( only supply ) 48.17 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only supply ) 48.18 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only labour ) 48.19 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( composite ) 48.20.a supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only supply ) 48.21 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only labour ) 48.22 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( composite ) 48.23 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class a insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only supply ) 48.24 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only labour ) 48.25 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( composite ) 48.26 supplying standerd first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage ( band aid ) adhesive tape for medicinal use, scissors, anti septic solution etc. ( only supply ) 48.27 testing and calibration of energy meters. 48.28 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only supply ) 48.29 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only labour ) 48.30.a supply and fixing of 33kv, epoxy type insulator for bus bar support ( composite ) 49.1 pa address system male –female, all kinds of audio / video pins ( only supply ) ( pair ) 49.2 male–female, all kinds of audio / video pins ( only labour ) ( pair ) 49.3 male –female, all kinds of audio / video pins ( composite ) ( pair ) 49.4 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only supply ) 49.5 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only labour ) 49.6 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( composite ) 49.7 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only supply ) 49.8 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only labour ) 49.9 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( composite ) 49.16 cable tie nylon 6 / 6 – uv stabilized uv stabilized nylon 6 / 6 use in continuous or extended exposure to outdoor sunlight. weather resistant grade, enduring additional ultraviolet ( uv ) light. 49.16.1 as per 49.16 for 100 mm size pkt for 100 nos ( only supply ) 49.16.2 as per 49.16 for 200 mm size pkt for 100 nos ( only supply ) 49.16.3 as per 49.16 for 300 mm size pkt for 100 nos ( only supply ) 49.17 multimeter make mecho , 415volt ( only supply ) 49.18 clamp meter mecho make , 415volt ( only supply ) 49.19 hand driven insulation tester 500volt ( only supply ) 49.20.a meggar digital insulation tester 500volt ( only supply ) 49.21 supply, installation, laying and connection of g.i. perforated & ladder type cable tray with bends, tees, clamps and couplers for fixing of cable with suitable ms structure and anchor fastner for supporting and necessary hardware with necessary welding has to be done to complete the job from isa / ismc / plate. the job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . all material shall be hot dip galvanised as per is ( 816 g / m2 ) and specifications. the structural steel supports for the trays are to be provided at every 1 mtrs. as per technical specifications. 49.21.1 600mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.2 300mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.3 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.4 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) perforated type tray 49.22 fiber accessories 49.22.1 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( only supply ) 49.22.2 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( composite ) 49.22.3 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( only supply ) 49.22.4 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( composite ) 49.22.5 supply of sm duplex type 03 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.6 supply of sm duplex type 10 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.7 supply of hdmi cable for monitor including end connectors 49.22.8 fiber core splicing charges per core composite work...

Rural Development Department - Maharashtra

37141993 supplying electrical materials and repair maintenance services at. grampanchayat nanekarwadi tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Directorate Of Municipal Administration - Maharashtra

37141987 tender for supplying required electrical materials and doing essential electrical work under municipal council hinganghat 2nd call. 1 supplying & erecting h.m.s. p.v.c. conduit 20 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 2 supplying & laying hms pvc conduit 20 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 3 supplying & erecting hms p.v.c. conduit 25 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 4 supplying & laying hms pvc conduit 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 5 supplying and erecting upvc reinforced flexible conduit 20 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 6 supplying and erecting upvc reinforced flexible conduit 25 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 7 supplying and erecting hms pvc conduit 20 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 8 supplying and erecting hms pvc conduit 25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 9 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 20 mm with accessories on wall / ceiling as per specification no: wg ma / con. 10 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 25 mm with accessories on wall / ceiling as per specification no: wg ma / con. 11 supplying & erecting mains with 2x1.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 12 supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 13 supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 14 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 15 supplying & erecting mains with 2x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 16 supplying & erecting mains with 3x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 17 supplying & erecting mains with 3x4 sq.mm fr copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 18 supplying & erecting mains with 3x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 19 supplying & erecting mains with 3x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 20 supplying & erecting mains with 4x16 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 21 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 22 supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6a. erected on filledpolypropylene board or polished double wooden block / pvcjunction box. 23 supplying and erecting isi mark modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 25 supplying and erecting isi mark modular type switch 16 / 20 a with indicator, duly erected on provided plate and box with wiring connections complete. 26 supplying and erecting isi mark modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete. 27 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 28 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 29 supplying and erecting isi mark modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 30 supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. 31 supplying and erecting isi mark modular type blanking plate two module, duly erected on provided plate & box. 32 supplying and erecting pvc surface modular switch box with double mounting plate for 2 modules duly erected. 33 supplying and erecting pvc surface modular switch box with double mounting plate for 3 modules duly erected. 34 supplying and erecting pvc surface modular switch box with double mounting plate for 4 modules duly erected. 35 supplying and erecting pvc surface modular switch box with double mounting plate for 6 modules duly erected. 36 supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 modules complete duly connected. 37 supplying and erecting pvc surface modular switch box with double mounting plate for 12 modules duly erected. 38 supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. 39 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. 40 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match thebackground. 41 supplying and erecting 16 / 20 / 25 a starter ( modular range ) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 42 supplying and erecting isi mark modular type 5 pin socket with safety shutters 3 module socket 6a 240v ac supply, duly erected on provided plate and box with wiring connectionscomplete duly erected. 43 point wiring for light / fan / bell in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw / sw 44 point wiring for independent plug in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as perspecification no: wg pw / sw 45 point wiring for light / fan / bell concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm. ( 2+1e ) fr grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / cw 46 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg pw / sw 47 wiring for plug on board with switch socket, copper wiring and earthing as per specification no: wg pw / sw 48 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw / sw 49 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories as per specification no: wg pw / sw 50 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no:wg pw / sw 51 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 52 point wiring in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wgpw / sw 53 point wiring for independent plug in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 54 supplying & installing utp networking cat 6 cable suitable for lan / wan computer net working as per specification no wg coc / nc 55 dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no: wg dm / pw 56 dismantling the existing aluminium / copper mains, submains wiring upto 10 sq.mm. along with accessories etc complete as per specification no: wg dm / pw 57 supplying and erecting led square / circular 9 to 12w down lighter having pressure die cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 58 supplying and erecting led square / circular 13 to 15w down lighter having pressure die cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 59 supplying and erecting square / round shaped crca / diecast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13w to18w with provision for plane front frame with translucent cover fixed to the housing complete. 60 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housingcomplete. 61 supplying and erecting led flexible strip light 5m length upto 25w conforming ip 65 of any colour with driver complete. 62 supplying & erecting led 18w tube light fitting ( 4 feet ) with polycarbonate housing, heat sink, integrated hf electronic driver complete. 63 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 64 supplying and erecting electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and ( effective range upto 45 meter ) bell on 250 v a.c. supply. 65 supplying and erecting electronic type driver for indoor led upto 19w 24w fixtures suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 66 supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminiumalloy and heat sink extruded aluminium complete per specification no . fg odf / fls2. 67 supplying and erecting led flood light fitting of 50w, including lamp, with pf > 0.95, class ip 65 and above class ip 65 and above housing of pressure die cast aluminium alloy andheat sink extruded aluminium complete per specification no fg odf / fls 2 68 supplying and erecting recess mounted 20w led wall washers, tilted 70° outwards and swivels 360° to offer best illumination on the wall with any colour with driver complete. ( including compatible driver ) 69 supplying & erecting 20w led par ( 30 lamp e 27 base, spoto series ) lights by making necessary arrangement / recess in wall to make it flush with surface. 70 supplying and erecting cylindrical shaped integral decorative with high power 12w 16w led bollard upto 1000mm with opal acrylic diffuser and ip65 protection on provided foundation complete. 71 supplying and erecting mushroom shaped integral 12w 16w led decorative bollard upto 680mm with ip65 protection on provided foundation complete. 72 erecting the departmentally supplied wp led street light / flood light fitting upto 80w. 73 erecting departmentally supplied led street light / flood light fitting upto 150w . 74 erecting departmentally supplied led street light / flood light fitting upto 400w . 75 supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb 76 maintenance of non eesl led light of all wattages of approximately 500 quantity 77 maintenance of55 nos of street light switiching box 78 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 79 supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. 80 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 81 supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5metre length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. 82 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 83 supplying and erecting fresh air cum exhaust fan of light duty250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 84 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 85 supplying and erecting five star rated energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn / cf 86 supplying and erecting condenser 2.5 micro farad for ceiling fan 87 supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 88 providing recess in brick wall suitable forerection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. 89 providing recess in brick wall suitable forerection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 90 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaustfan of 300 mm as per specification no fg fas / msc 91 dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with accessories, g.i. down rod, frame etc. and making the site clear. 92 providing fully comprehensive annual maintenance service for 80 / 120 / 150 ltr. water cooler unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares including minor electrical parts within 48 hours. 4 ) refrigerant charging if required. 5 ) if failed to rectify the fault within 48 hrs penalty shall be charged rs.50 / per day.the job exclude sheet metal work and plastic material. 93 providing servicing of 1 / 1.5 / 2 / 3 tr capacitysplit / window air conditioning unit complete with allnecessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to engineer incharge. 94 providing annual comprehensive maintenance contract for 1.5 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 95 providing annual comprehensive maintenance contract for 2 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 96 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 1.5 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 97 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 2 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 98 providing replacement of unserviceable starting capacitor for a / c unit. 99 providing replacement of unserviceable running capacitor for a / c unit. 100 providing replacement of unserviceable fan motorcapacitor for a / c unit. 101 providing replacement of unserviceable pcb for a / c unit upto 3 tr capacity. 102 providing repair of of faulty pcb for air conditioning unit upto 3 tr capacity. 103 supplying and installing of new fan motor for condenser for air conditioning unit 104 providing vaccumising the airconditioner system and charging with r 22 refrigerant for air conditioning unit. 105 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 1.5tr window / split air conditioning unit. 106 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 2tr window / split air conditioning unit. 107 providing replacement of existing unserviceablecompressor of 150 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerent with guarantee for one year. 108 providing replacement of existing unserviceablecondensor coil of 40 / 80 / 150 litre cooling capacitywater cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 109 providing replacement of existing unserviceable ss water tap of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 110 providing replacement of existing unserviceable relay 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 111 providing replacement of existing unserviceablethermostat of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 112 dismantling the existing split type air conditionerof any type and capacity safely without any damages and making the site clear. 113 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / gi frame as per specification no. sw swr / mdp . 114 supplying and erecting double pole metal clad switch with hc type fuse 240v, 63a on iron / gi frame as per specification no. sw swr / mdp. 115 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specification no. sw swr / mtp. 116 supplying and erecting triple pole metal clad switch and fuse 415v, 100a on angle iron / gi frame as per specification no. sw swr / mtp. 117 supplying and erecting triple pole metal clad rewireable fuse switch 415v, 200a on angle iron / gi frame as per specification no. sw swr / mtp. 118 supplying and erecting four pole metal clad on load change over switch 415v, 100a erected on angle iron / gi frame complete. 119 supplying and erecting four pole metal clad on load change over switch 415v, 200a erected on angle iron / gi frame approved make complete. 120 supplying and erecting metal clad distribution board 240v, 8 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 121 supplying and erecting metal clad distribution board 240v, 6 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 122 supplying and erecting metal clad distribution board 240v, 4 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 123 supplying and erecting metal clad distribution board 415 v, 8 way, 32a. per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 124 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 125 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 126 supplying, erecting & marking spn mcb 6a to 32a, bseries ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 127 supplying, erecting & marking tpmcb 6 a to 32a in provided distribution board as per specification no. swswr / mcb 128 supplying, erecting & marking fpmcb 6a to 32a in provided distribution board as per specification no. sw swr / mcb 129 supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 130 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 131 supplying, erecting & marking tpn mcb 6a to 32a, c series in provided distribution board as per specification no. sw swr / mcb 132 supplying, erecting & marking tpn mcb 40a to 63a, c series in provided distribution board asper specification no. sw swr / mcb 133 supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 134 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 135 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 63a with required wiring connections and lugs etc. in provided distribution board complete. 136 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100a with required wiringconnections and lugs etc. in provided distribution board complete. 137 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board complete. 138 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63a in provided distribution board complete. 139 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 80 / 100a in provided distribution board complete. 140 supplying and erecting triple pole and neutraldistribution board ( tpndb ) surface / flushmounted suitable for spmcb of 12 poles on iron / gi frame ( horizontal busbar type ) as per specification no. swswr / mcbdb 141 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 142 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 143 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 144 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 145 supplying & erecting original 1.25 mm crca sheet metal enclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete erected on angle iron / gi frame. 146 supplying and erecting blanking plate of suitable size on mcb db complete. 147 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 16 / 25a complete as per specification no.sw rccb / rccb 148 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 149 providing, erecting and commissioning 4 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 150 providing, erecting & commissioning 4 pole rccb of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 100a, complete as per specification no. sw rccb / rccb 151 supplying & fixing crca sheet box with earthing terminals for housing 2 pole rccb on iron frame / laminated board complete. 152 supplying & fixing crca sheet box with earthing terminals for housing 4 pole rccb on iron frame / laminated board complete. 153 supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. 154 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 155 supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 156 supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 157 supplying and erecting gi sheet 1.6 mm ( 16 swg ) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for medium voltage installation. 158 supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions bythe authority. 159 supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 160 supplying, erecting & terminating xlpe armoured cable 3 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 161 supplying, erecting & terminating xlpe armoured cable 3 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 162 supplying, erecting & terminating xlpe armoured cable 3 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 163 supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 164 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 165 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in providedtrench / pipe as per specification no. cb lt / al 166 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 167 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / cu 168 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 169 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 90 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 170 supplying & erecting water tight terminal box of 1.6 mm ( 16 gauge ) crca sheet of size 200 x 150 x 150 mm. complete on pole as per specification no. cb sb 171 supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 172 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75 m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp 173 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 174 supplying and erecting pre stressed cement concrete ( psc ) rectangular pole of top 105 x 115 mm & bottom of 105 x 315 mm 9 m long ( 200 kg ) complete erected in provided c. c. foundation & muffing ( square / round ) as per specification no. oh pl / psc 175 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 176 supplying & erecting ms pole bracket, for oh conductor fabricated from ism channel, 75x40x6mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 177 supplying & erecting ms pole bracket, fabricated from ism channel, 75x40x6mm, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 178 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 179 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 180 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips , nuts and bolts, complete. 181 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length andpole clamps duly erected in provided cement concrete foundation. 182 supplying and erecting fibre / pvc spacers for lt overhead line 3 to 5 conductors complete erected. 183 supplying and erecting ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 184 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 185 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 186 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep 187 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 188 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 189 supplying and erecting aluminium strip of required sizes used for earthing on wall and / or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required.as per specification no ea ep. 190 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary giclamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no ea ep. 191 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit withscrews in an approved manner. 192 providing printed instruction chart for treating persons suffering from electric shock, printed in english & marathi and duly laminated complete. 193 supplying and fixing pvc synthetic elastomer electrically insulating mat with class a insulation conforming to is: 15652 – 2006 & cpri tested having 2 mm thickness upto 3.3 kv 194 supplying and fixing pvc synthetic elastomer electrically insulating mat with class b insulation conforming to is: 15652 – 2006 & cpri tested having 2.5 mm thickness upto 11 kv 195 supplying shock proof leather safety shoes of electrical grade of standard size as is :11226, 14544 duly tested, with necessary test certificate from manufacturer. 196 carrying out servicing of dg set upto 50 kva with / without amf panel of any make to ensure smooth running of dg set for 30 mins on load. checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. inspect alternator, stator and rotor for normal speed & proper frequency, examine batterycharging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking v belts with necessary adjustment, checking and retightening of nut bolts including coupling boltsof engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of avr, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, cleaning of dg set internally using blower, cleaning radiator and submit the servicing report to engineer in charge. ( non comprehensive ) as per specification no. gen ser amc 197 topping up new lubricating oil 15w / 40 grade of approved make as per is 13656 : 2014 198 topping up new glycol based coolant 50 / 50 with operating range from 118°c to 37°c of approved make 199 supplying and erecting v belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for dg set upto 100kva 200 supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for dg set upto 62.5 kva. 201 supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for dg set upto 50 kva. 202 supplying and erecting stop solenoid assembly 12v / 24v single coil energized to run with or without primary etc complete suitable for dg set upto 125 kva. 203 supplying and erecting air cleaner / air filter element suitable for dg set upto 40 kva 204 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 205 making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exnctr 206 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 207 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing andfinishing complete. ( above 6 m to 9 m poles ) 208 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 209 making m 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with thehelp of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 210 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. specification no cw ptg / ptp. 211 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 212 rewinding motor of the 1200 / 1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption withguarantee for one year. 213 replacing the existing ball bearing of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 214 replacing the existing bush / rubber, ring, washers of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 215 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c.. submersible / centrifugal pump set upto 2 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 216 supplying and installing 25 kva koel generators generator panel with 3 years warrenty. 217 doing rewinding and repairing cooling fan of 1400rmp 220v 218 doing repairing and fixing of thebroken main gate of 25 kva generator with required accessories. 219 supplying and installing fuel cap for 25 kva generator. 220 doing servicing of highmast ( upto 15 mtr ) with lowering of lights, cleaning ropes pathway lubricating the mechanisam with all necessary accessories. 221 supplying and erecting new rope in the highmast ( upto 15 mtr ) by dismantling highmast with proper equipments. 222 maintenance of 15 nos ofdecorative pole of 15w at park...

Rural Development Department - Maharashtra

37128996 providing led street fitting on 8 mtr pole at kolgaon , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30no x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying and erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. ( 5 2 3 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( 6 1 19 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no.cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per per specification no. cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no.o ea ep ( 9 1 4 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 ) ...

Central Railway - Maharashtra

37063214 supply of water boiler of 30 ltrs 3 kw capacitywater boiler of 30 ltrs 3 kw capacity, water boiler of 30 ltrs 3 kw capacity for hot buffet lhb type coaches generally conforming to is:3412 along with control box & necessary plumbing & tap arrangement on a common base plate conforming to rcf specification no. edts 118, rev. e & drg. no. lh 72221. material shall procure from rdso / rcf / icf / mcf approve source only....

Central Railway - Maharashtra

37055987 supply of set of diaphragm and o ringset of diaphragm and o ring, set of diaphragm and o ring for pressure governor ( ii35829 / 05545 ) . set consists of : 1 ) diaphragm to kbi part no. kn mcs11g ii35829, qty.=01 no. / set , 2 ) o ring to kbi part no. b57679 , qty.=01 no. / set & 3 ) o ring ( base plate ) to kbi part no. a37523 , qty.=01 no. / set. set consists of 03 items in 03 nos. [ warranty period: 30 months after the date of delivery ] ...

Central Railway - Maharashtra

37055401 supply of set of diaphragm & o ring for pressure governor ( ii35830 / 00603. set consists of : 1 ) diaphragm to kbi part no. kn mcs4g ii35830, qty.=01 no. / set , 2 ) o ring to kbi part no. b57679 , qty.=01 no. / set & 3 ) o ring ( base plate ) to kbi part no. a37523 , qty.=01 no. / set. set consists of 03 items in 03 nos. [ warranty period: 30 months after the date of delivery ] ...

Directorate Of Municipal Administration - Maharashtra

37037704 annual maintenance contract of electrical department for indapur municipal council for year 2023 24 1 supplying & erecting mains with 2x10 sq.mmf.r copperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 2 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 3 supplying & erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw 4 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire. 5 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire 6 supplyinganderectingisi mark g.i. pipepole ‘b’ grade80 mm dia 6 m longwith pole cap, base plate in provided foundation as per specification no. oh pl / gip 7 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 8 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm diawith 4.5 x 3.65 x 3.25 mm thickness ( 5+2+2 m ) length respectively and total9 m long with pole cap, base plate in provided foundation ( weight 113 kg ) as perspecification no 9 providing & erecting 7 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 130 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 10 providing & erecting 9 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 155 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 11 providing and erecting galvanised 1000mm single arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 12 providing and erecting galvanised 1000mm double arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 13 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as perspecification no. oh pl / bkt 14 supplying and erecting g.i. pipe ‘c’ class erw 25 mm dia with necessary fittings complete as per specification no. 15 supplying and erecting g.i. pipe ‘c’ class erw 50 mm dia with necessaryfittings complet 16 supplyinganderectingpole clamp madefrom50 x 6 mmms flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 17 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea ep 18 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. ea ep 19 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per 20 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) 21 making m 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supplyof steel, concrete, excavation and fixing provided nut bolts with the help oftemplate, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) 22 making m 20 cement concrete foundation by considering the safe soilbearing capacity at site as 10 t / sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per designcomplete ( for 12.5 m raising lowering high mast ) 23 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp. 24 supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 25 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 26 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 27 supplying and erecting porcelain base iron clad cut out hc type 415v, 100aerected on polished wooden block. 28 supplying and erecting porcelain base iron clad cut out hc type 415v, 200aerected on polished wooden block 29 supplying, erecting & marking tpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 30 supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb 31 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 32 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 33 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 34 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 35 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 36 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / cu 37 supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supplyup to 7.5 h.p. 38 supplying & erecting fully automatic star / delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame 39 supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 40 supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 41 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 90 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 42 supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. cb cl / cu 43 supplying & erecting crimping type copper lugs for cable120 sq. mm. completeas per specification no. cb cl / cu 44 supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. ( meter pannel box ) 45 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw / hw 46 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing ncapping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories 47 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or anyother places. as per specification no: wg ma / bw 48 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 49 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 50 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation 51 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. 52 supplying and erecting integrated led street light fitting 23 to 25w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 2300 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3years warranty as per specification no fg odf / fls2. 53 supplying and erecting integrated led street light fitting 40 to 50w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3 years warranty as per specification no fg odf / fls2. 54 supplying and erecting integrated led street light fitting 70 75w ip65 & ik08class having single piece pressure die cast aluminium housing, having systemlumens output of min. 7700 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuiltsurge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including drivercomplete with 3 years warranty as per specification no fg odf / fls2. 55 supplying and erecting integrated led flood light fitting max. 70w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min. 8400 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2. 56 supplying and erecting integrated led flood light fitting max. 120w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min.14500 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2 57 erecting departmentally supplied led street light / flood light fitting above80 to 150w . 58 supplying and erecting street light bracket made from 40 mm. dia ‘b’ classg.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm diaduly welded with provided leads as per specification no. fg bkt / bpc 59 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 60 supplying and erecting electronic type driver for outdoor led fittings 151w 200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 61 supplying and erecting t8 fluorescent tube day light 600mm, 18 w 62 supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete &compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. 63 supplying and erecting flush type shockproof plug socket 6a & 16a ( 6 pin ) with 16a switch combined with indicator lamp and fuse with gang box onwooden board 64 supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete 65 supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e 27 base 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based oninsulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 67 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs.based on insulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 68 supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kva capacity online pure sine wave ups, with backup time of .......hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups 69 supplying and erecting 12v / 200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 70 supplying and erecting 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 71 providing servicing of 1 / 1.5 / 2 / 3 tr capacity split / window airconditioning unit with all necessary material. job includes checking ofperformance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to engineer incharge. 72 providing annual comprehensive maintenance contract for 1.5trsplit / window air conditioning unit complete as per terms and conditions. jobincludes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within24 hours 4 ) sending standby manpower for vip movement. the job exclude sheetmetal work and plastic material 73 providing brazing pipes and checking leakages in the split / window unitduly with dry nitrogen pressure, complete. 74 providing replacement of unserviceable pcb for ac unit upto 3tr capacity 75 supplying and erecting quartz electronic time switch having 24 hour dial towork on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteriesto run the time switch on failure of supply having switch contact rating up to 16ato use independently or in conjunction with contactor 76 supplying and erecting four pole power contactor 430 v, 40 a for time switchcomplete erected on provided wooden block / box, with necessary materials 77 supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “on” and switching“off” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit led continuous time display, relay output 230 v / 10a with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided m.s. box 78 supplying and erecting static energy meter with 240v 50 hz. ac supply 10to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring anddisplay kwh, kvah, v, i, pf, frequency, kw, kva, six months history ofenergy & md in kw & kva ) with transparent hinge type box completeerected on polished teak wood board duly wired with required size ofweather proof pvc wires duly tested by electric supply company 79 supplying & erecting crimping type aluminium lugs for cable 240 sq mmcomplete as per specification no. cb cl / al 80 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm.complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 81 supplying and erecting 3 phase 4 core 35 sq.mm. ( 3x35+1x25 ) aerial bunchedaluminium cable along with necessary accessories for lt distribution onprovided lt pole as per specification no. oh cbl / abc 82 supplying and erecting g.i. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, g.l. staywire 7 / 10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete 83 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level. 84 supplying and erecting of isi mark insulation tape 85 supplying and erecting of isi mark nutbolts 86 supplying and erecting of isi mark tester 87 supplying and erecting of isi mark led zero bulb 88 supplying and erecting of isi mark led zero bulb holder 89 supplying and erecting fault clearing on street light conductor 90 supplying and erecting of ac servicing 91 supplying and erecting of filter servicing 92 supplying and erecting of batery servicing with water change 93 supplying and erecting of ro membrane for filter 94 supplying and erecting isi mark extension box...

Rural Development Department - Maharashtra

37032797 tender for civil work material supply , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30no x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying and erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. ( 5 2 3 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( 6 1 19 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no.cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per per specification no. cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no.o ea ep ( 9 1 4 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 ) ...

Mazagon Dock Limited - Maharashtra

37031292 base and depot spares for store lift for 4 ships of mdl ( yard 12651 12654 ) and 3 ships of grse ( y 3022, 3023 and 3024 ) of project 17a all per tender document , supply of following items , rope guide pulley with bracket store l , roller guide shoe store lift p17a , instances safetyguide frame store lift , collapsible gate store lift p17a , drive drum rope guide store lift p17a , rope guide limit switch plate store li , drive bearing housing with cover store , coupling store lift p17a , t rail store lift p17a , t rail holder store lift p17a , t rail base plate store lift p17a , sring buffer base plate store lift p17 , sotre lift shock absorber store lift p , lifting handle store lift p17a , mechanical locking store lift p17a , rope guide limit switch store lift p17 , shock mount with stud store lift p17a , door limit switch store lift p17a , floor level limit switch store lift p1 , floor stop limit switch store lift p17 , main hoist wire rope 12mm ( 30 mtrs ) st , wire rope for speed governor ( 6 mm ) ( 20 , speed governor store lift p17a , std. junction box with connecwell termin , electrical flexible cable multicore ( 80 , electrical flexible cable for motor ( 15 , electrical flexible cable for sensors ( 5 , motor cable gland store lift p17a , telephone cable ( 50 mtrs ) store lift p , selector switch 2 maintain position sche , single pole toggle switch store lift p , contactor rated 9a, 220v ac coil schneid , 24v dc relay, 2 c / o with led phoenix make , meanwell store lift p17a , mcb rated 32a, 3 pole scheider make st , mcb rated 6a, 2 pole scheider make stor , mcb rated 10a, 1 p0le scheider make sto , mcb rated 25a , 3 pole scheider make st , mcb rated 2a, 2 pole scheider make sto , indicating lamp white 24 v dc store li , indicating lamp white 230 vac store li , red pilot lamp 24 vdc store lift p17a , indicating lamp amber colour 24 v ac / d , buzzer cum flasher 24v dc store lift p , raj electricals make store lift p17a , smps, 5a 24 v dc phoenix make store li , 16 digit input card , ib il 24 di 18 st , 16 digit output card, ib il 24 di 18 st , terminals 6 a store lift p17a , yellow push button scneider make store , fuse link 2 a store lift p17a , shrouded pb green colour scneider make , shrouded pb yellow colour scneider make , mashroom pb red colour scneider make s...

Directorate Of Municipal Administration - Maharashtra

36972039 annual tender of motor rewinding and maintenance of 1 hp to 175 hp motors , pump of water supply department for 2023 24 , 1 hp to 7.5hp submersible borewell motor rewinding rate per hp , ball locator , di fragum , di fragum cap , drain plug , thrust segment assembly , thrust color , counter thrust ring , botom bearing housing , bush , t bolt , slieve , rotor with shaft , oilkseal slieve , stator housing aseembly , o ring , coupling , stainer , stud , stud guard , thrust bearing fibre , thrust bearing carbon , im peller , 5 hp, 20 hp submersible open well motor rewinding rate per hp , ball locator , di fragum , di fragum cap , drain plug , thrust segment assembly , thrust color , counter thrust ring , botom bearing housing , bush , t bolt , slieve , rotor with shaft , oilkseal slieve , stator housing aseembly , top housing , o ring , coupling , stainer , stud , stud guard , thrust bearing fibre , thrust bearing carbon , im peller , , 1 hp to 10 hp monoblock pump set rewinding rate per hp , ball locator , di fragum , di fragum cap , drain plug , thrust segment assembly , thrust color , counter thrust ring , botom bearing housing , bush , t bolt , slieve , rotor with shaft , oilkseal slieve , stator housing aseembly , top housing , o ring , coupling , stainer , stud , stud guard , thrust bearing fibre , thrust bearing carbon , im peller , , 15 hp to 50 hp monoblock pump set rewinding rate per hp , ball locator , di fragum , di fragum cap , drain plug , thrust segment assembly , thrust color , counter thrust ring , botom bearing housing , bush , t bolt , slieve , rotor with shaft , oilkseal slieve , stator housing aseembly , top housing , o ring , coupling , stainer , stud , stud guard , thrust bearing fibre , thrust bearing carbon , im peller , , 2 hp to 15 hpbare motor rewinding rate per hp , ball bearing , oil seal , gland , flange , bearing shaft , im peller , slieve , bushing , packing , , stud , studguard , end cap , air fan , cotter pin , connection plate , washer , couple , , 40hp vt pump, 75 hp vt pump rewinding rate per hp , mainshaft s.s. repair , brass bush ball , rubber bush ball , adapter bush , rock bush ball , ball bottom bush , mechanism steel , connector bush , nutbolt , lan shaft , m. s. coupling , aluminium mtr , longshaft bearing brass , rubber spider , gland bush , , motor transportation , oil ( for all vt pump ) , work shop rate , 175 hp vt pump 175hp rewinding , mainshaft s.s. repair , brass bush ball , rubber bush ball , adapter bush , rock bush ball , ball bottom bush , mechanism steel , connector bush , nutbolt , lan shaft , m. s. coupling , aluminium mtr , longshaft bearing brass , rubber spider , gland bush , work shop rate , motor transportation , 1 hp to 7.5 hp bare / openwell / submerssible / monoblock motor starter pannel box repairing starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , copper cable ( for all ) , service cable ( for all ) , 7.5 hp to 10 hp bare / openwell / submerssible / monoblock motor starter pannel box repairing : starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , copper cable ( for all ) , service cable ( for all ) , 12.5 hp to 50 hp bare / openwell / submerssible / monoblock motor starter pannel box repairing starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , copper cable ( for all ) , service cable ( for all ) , 50 hp monoblock motor starter pannel box repairing : starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , copper cable ( for all ) , service cable ( for all ) , 40 hp / 75 hp starter pannel box repairing : starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , brass nut / stud , brass lugs , brass washer , cable , 175 hp vt pump starter pannel box repairing : starter pannel box repairing and installation , relay , coil , contact kit , base , lugs , base plate , contactor , indicator , push button , kitkat set , brass nut / stud , brass lugs , brass washer , auto transformer oil , auto transformer rewinding rate per hp , auto transforme transport charges , cable , auto transforme fitting charges / service charges...

Central Railway - Maharashtra

36966878 supply of universal point group relay type rssk 31 / 0015 without base plate as per rdso specn. no irs s:46 and latest. make siemens [ warranty period: 30 months after the date of delivery ] ...