Shri Saibaba Sansthan Trust - Maharashtra

34976248 proposed quotation for supply, installation, commissioning and testing of compact substation, generator set, ht metering cubical panel, main distribution panel, cables and ancillary work for increased load of shri sainath hospital and dwaravati bhaktanivas building for shri sai baba sansthan trust, shirdi....

Tapi Irrigation Development Corporation - Maharashtra

34914516 supplying, erecting, testing and commissioning of distribution panels along with necessary switchgears and repairs to sub distribution panel on barrage hoist at prakasha barrage tal. shahada dist. nandurbar...

Directorate Of Industries - Maharashtra

34687512 supply, erection and commissioning of transformer and electrification work ( turnkey job ) 1 supply, errection & commissioning of transformer and electrification work ( turnkey job ) total cost in cif premises at m / s. nuaxe techno engineering council, 2246 / d, at post malgav, dist. sangli, state maharashtra, india, including gst, all applicable taxes, transportation, insurance, unloading, installation & commissioning, agency commission, packing, forwarding, any other taxes / charges / local taxes as applicable etc., on site technological training, training for mechanical and electrical maintenance for 4 persons for 2 weeks. 2 315 kva transformer 3 power distribution panels 4 readymade disribution boards 5 cables and end termination 6 cable tray & supports 7 light fittings 8 power mains & point wiring 9 earthing stations 10 cctv system piping 11 service point...

Department Of Fertilizers - Maharashtra

34531302 bids are invited for supply of power distribution panel power distrib. panel, prom project , power distrib. panel, vap project total quantity : 3...

Directorate Of Purchase And Stores - Maharashtra

34470677 fabrication, testing, supply, installation and warranty of electrical distribution panel pcc2 fabrication, testing, supply, installation and warranty of electrical distribution panel pcc2 with 200amps incomer, for aump , electrical distribution panel pcc2 with 200amps incomer, for aump...

Reserve Bank Of India - Maharashtra

34264469 tender for supply, installation, testing & commissioning of electrical distribution panels and lt cabling work in the basement at the bank’s central office building at fort, mumbai....

Tata Memorial Centre - Maharashtra

34260320 computational biology centre and cross talk lab on turnkey basis at actrec engineering, procurement supply, installation, testing and commissioning of computational biology centre and cross talk lab on turnkey basis at actrec , part – a: core infrastructure , civil , demolishing existing brick masonry with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry / rcc structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises and scope also include dismantling and careful removal of doors, distribution panel and storing and stacking complete all as directed by the engineer in charge. ( existing toilets, guard room & record room & ground floor & all areas wherever required for hpc facility ) , dismantling of wash basin and removing of wall tiles and all the allied stonework and pipes & fittings wherever necessary and disposal of unserviceable material carting away the debris out of hospital premises or handing over the same to engineer in charge , flooring breaking: dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandoor stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material and disposing unserviceable material out of hospital premises as directed by the engineer in charge. , dismantling and removal of complete fire fighting system and handing over all the material ( without any damage ) anywhere within the campus as per the instructions of engineer in charge. this includes plant, machinery, equipment for cutting, welding and dismantling complete material safely. , demolishing cement concrete and bitumen road / kerb stone manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. , providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle size 600mm center to center, lock and stopper etc. included in the item rate ) . anyquality approved by engineer incharge based on sample. , providing and fixing of hollow metal un insulated fire rated doorsas per is 3614 part 1, for stability and integrity. pressed galvanized steel confirming to is 277 with the following specification. recommended fire door shall be tested to is 3614 part 2 / iso 834 1 part 1 / bs476 part 20 & 22, cbri / certifire or third party certified or equivavelent lab, for maximum rating of 120mins, .labeled doors with certification shall be with vision glass as a part of complete assembly. deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. proper label confirming the type of door and the hourly rating is mandatory. door frame shall be single rebate grooved profile of size125 x 60mm made out of 1.60mm ( 16gauge ) minimum thick galvanized steel sheet. frames shall be mitered and field assembled with self tabs.door frames should be prepared for suitable hardware and should have necessary reinforcement to withstand regular wear and tear.frames to have inbuild grooved sealing system and shall be site fitted with fire rated epdm gasket as standard. all provision should be mortised, drilled and tapped for receiving appropriate hardware. door leaf shall be 46mm thick fully flush double skin door, un insulated with vision lite. door leaf shall be manufactured from 1.2mm ( 18guage ) minimum thick galvanised steel sheet. the internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. the edges should be interlocked with a bending radius of 1.4mm. for pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. the glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.all doors and frames shall be finished powder coated and shall have passed minimum 500 hours of salt sprey test. rate shall include supply and installation of door and hardware as a complete assembly including door closure, hinges etc..all doors shall be provided with stainless steel hinges with concealed door closures of required capacity and rating. provision of access control interlock and wiring shall be made in all door shutters and frames with requisite hardware. rate excludes installation of panic bar. , supply and fixing of slim glass partition of 12mm toughened glass using system 45 frames to a height of maximum 3m or as per drawing.the fixed glass to be fixed usingbp45 profiles at top & bottom &sp45 at sides ( the profile is for reference ) . the profile size to be 45x25mm to be fixed on to the floor / wall / ceiling as per the architect design.h junction profile to be used at all glass to glass vertical joints, 90 deg l junction profiles and t junction profiles necessary as per design.in case of glass overall panel mp45 & bp45 overpanel profile to be used.in case of open glass edges ep45 end profile to be used. the alexa profiles shall be suitable for glass thickness of 10 / 12 / 13.52mm.the profile shall be 20 micron matt natural anodized, the profile manufacturer to supply all the necessary clips, seals and fixing accessories for the system. all profiles to be with 2 mm gauge thickness including 20 micron of anodizing. , supply & installation of 2 hrs fire resistance rated fm approved sandwiched wall panels with 0.80 mm skin thickness with overall thickness of 150mm and with 98 + 2kg / cu.m density of rockwool insulation. both sides gi powder coated sheet as per clients approved shade along with flashing and with water resistant silicon sealant at required area and providing necessary accessories for fixing of metal partitions as per drawings with gi profile for reinforcement. ( inclusive of bottom track / interlock sections / silicon ) ( certificate for fire rating to be provided ) . vision glass on all sides for direct observation of hpc from outside should be compatible with partition and in fire rating and with maximum dimension of 1m*1m. with porcelain finish having rewritable capabilites and printing work to be done wherever required as per the instruction of engineer in charge. one side measurement will be taken. anyquality approved by engineer incharge based on sample. , supply & installation of 2 hrs fire resistance rated fm approved sandwiched wall panels with 0.80 mm skin thickness with overall thickness of 50mm and with 98 + 2kg / cu.m density of rockwool insulation or 40+ 2kg / cum puf insulation . both sides gi powder coated sheet as per clients approved shade along with flashing and with water resistant silicon sealant at required area and providing necessary accessories for fixing of metal partitions as per drawings with gi profile for reinforcement. ( certificate for fire rating to be provided ) as per the instruction of engineer in charge. one side measurement will be taken. , supply & installation of 80mm thick sliding folding partition with aluminium frame, track and trolley and 1mm thick hard pressed laminate finish of approved shade on both sides in the middle of conference room including all the hardware, accessories and rotating and retracting mechanism required as per the instruction of engineer in charge complete. one side measurement will be taken. , toughened lacquered glass panelling: providing and fixing of 6mm thick toughened glass ( premium griha rated lacquered glass from glass manufacturer ) of approved colour by doit&c, mounted on clip ( j / j1 / i type ) or equivalent on a perfectly levelled surface ( 12mm thick water proof marine plywood / acc blockwork / aluminium channel / bare rcc wall surface ) . lacquered strong glass must be made industrially ( via curtain coating process ) ; opaque ( if viewed against a support wall ) , coated with pu lacquer ( 100 micron thick ) ; colour consistency ( measured by spectrophotometer cm5081 ) ; highly durable ( passes persoz hardness test for minimum 220 oscillations ) ; humid resistant ( conforms to bs en 1036 1999 ) ; environmentally friendly ( no lead, no arsenic, no copper, no formaldehyde ) ; appropriate recycled content ( 12% post industrial / 6% post consumer ) ; compressive strength ( 1000 mpa ) & tensile strength ( 40 mpa ) , same as float glass. tempering should be done as the en 12150. glasses are to be fixed with polymer clips ( single sided j1 & j2 type, double sided i type ) , white backing foam and grey impact absorbing foam; to accommodate upto ± 10mm substrate undulation, and with a horizontal load capacity of 30kg / 100mm and vertical pullout load > 200kg / 100mm, glass should be supported with 1mm thick lip covering upto 3mm of glass surface; clips should be fixed using durable, non corrosive, strong s.s.screw 45mm long. all wooden material to be used shall be anti termite treated. the measurement only for the portion covered by glass to be considered. , providing and fixing fabric backing commercial grade wall paper of approved shade with recommended adhesive of approved quality which have 100% washable, scratch resistance, peel proof, and fire retardant properties. the wall paper should give a seamless finish. including cost of preparation on the base surface for fixing the wall paper as per the manufacturer specification, complete in all respect as per direction of eic. , supply & installation of 80mm thick insulated metal partition cladded with fabric and insulated with glasswool / rockwool for sound insulation. the partition should have provision for modular electrical and plumbing fittings as per the site conditions. skin thickness 0.6 to 0.8mm. finish : powder coated. face of partition : interior face: g 90 galvanized or az 50 aluminum zinc coated steel in 26, 24 and 22 ga. , supply & installation of 80mm thick insulated metal partition cladded with fabric ( towards conference room ) , on the other side clad with marine mdf. insulated with glasswool / rockwool for sound insulation. the partition should have provision for modular electrical and plumbing fittings as per the site conditions. skin thickness 0.6 to 0.8mm. finish : powder coated. face of partition : interior face: g 90 galvanized or az 50 aluminum zinc coated steel in 26, 24 and 22 ga. , providing and fixing flush doors 35mm thick with 1.0 mm laminates on both sides. the item includes teakwood chaukhat ( frame ) made from 75x50 teakwood. the door to have 12mm teak wood lipping on edges. the door is to be complete with cylindrical door lock , 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. , providing&fixing 50mm thick bwpgradesingle leaf flushdoorofsize ( 1200 x2400 ) includingteakwood lippingpatti12x55mmtoachieveexposedperiphery section of flush door finished with4mmthick veneer outside & inside 1 mm thick laminate with suitable mounting door frame as required. allwood& veneer surfaces shall be finished with melamine polish as per approvedtint includingmoulding, nails, screws, fevicol including necessary scaffolding & cleaning as per architects detailed drawing & design etc. complete. the door is to be complete with cylindrical door lock, 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. ( d1 ) , providing and fixing panic bar / latch ( double point ) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the engineer in charge, all complete. , providing and constructingaac light weight block masonry with 75mm / 100mm / 150mm / 200mm / 300mm thick at all levels in by using approved block laying polymer modified adhesive mortar, including 75mm thick patli / stiffeners of m 15 gradeat every 1000mm with 2 nos 8mm steel bars all to be considered in the cost and no separate measurement will be done for steel and patli, also including scaffolding, racking out joints, curing with curing compound etc. in line, level and plumb, all complete as per specification for all height of floor or as directed etc. ( rate includes the cost of stiffeners hoop ) . ( no holes for scaffolding will be permitted into the blockwork ) , grproc plaster : providing andapplying 1stqualitygyprocplaster ( gyproc elite 90 ) including bonding coat of gyproc bondwith minimum 10 12mm thickness to internal brick / block / concrete walls at all position in proper line, level and plumb including scaffolding, cleaning, hackingofconcretesurface, removing debris out of site etc. complete. as directed to achieve perfect line level and plumb. , providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. , providing and applyingacrylic ( premium ) emulsion paint of approved qualityandshadeonwallswithsand papering& cleaning the surface, applying one coat of primer and lambi / puttytofullsurface3times, thereafterpaintingthe surfaceintwo coatsoverbaseprimercoattoachieveeven finish. rate is inclusive of all double scaffolding, all material and cleaning as per manufactures standard application method & specification etc. complete. , providing and fixing artificial grass with recommended adhesive of approved quality which have 100% washable, peel proof, and fire retardant properties. the grass should give a seamless finish. including cost of preparation on the base surface for fixing the grassas per the manufacturer specification, complete in all respect as per direction of eic. , providing and installing of 8mm thk brick claddingas per the manufacturer specification in approved pattern with backing coat of 1:4 cement plaster and neatcementfloatusingpolymerbasedtileadhesivesof approved quality including filling joints, complete in all respect as per direction of eic. , providing and laying 600 x 600 vitrified tiles as specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirting ofanapproved, quality, and pattern / design for flooring including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge.as per manufacturers specifications. , providing and laying 800 x 800 vitrified tiles as specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirting ofanapproved, quality, and pattern / design for flooring including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge.as per manufacturers specifications. , providing and layingoutdoorvitrifiedtiles600mmx600mmas specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirtingofanapproved, quality, and pattern / design for flooring and skirtingincluding cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge. , providing and layinglapato finish vitrified tiles 600mm x 600mmas specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooringand skirting ofanapproved, ` and pattern / design for flooring and skirting including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge. , providing and fixing 1st quality antiskidceramic floortile size 300x300 mm or more ( thickness to be specified by the manufacturer ) for flooring and skirting confirming to is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete ( including the cost of cement mortar bed 1:4 ) . , providing and laying machine cut, mirror polished approved coloured granite slab of any approved size 20 + / 2mm thick for flooring in required pattern with approved coloured granite inlay work on a bed of 1:4 cement mortar including neat cement float, filling joints with neat coloured cement slurry, to match the colour of granite, curing, polishing and cleaning complete. , providing and laying machine cut, mirror polished marble stone flooring and skirting, in required design ( simple geometrical, abstract etc. ) and in patterns in combination with italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with white cement slurry @ 4.4 kg / sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge. in combination with 18 mm thick italian marble stone slab, perlato, rosso verona, fire red or dark emperadore etc is to be included. , providing and fixing machine made synthetic carpet having total carpet weight more than 550 gm / sqm. and more than 5mm thickness superior quality complete in all respect as per direction of engineer in charge. ( euronics or equivalent quality preapproved by engineer incharge ) , providing and laying machine cut, river finish graniteof anyapprovedsize20+ / 2mm thick for flooringin required patternwithapprovedcolouredgraniteona 20mm thick bedof1:4 cement mortar including neat cement float, filling joints with neatcolouredcementslurry, tomatchthe colourof granite, curing, polishingandcleaningcomplete. , providing & laying ofimported engineered wooden flooringofsize 215 mm width xlength 2200 mm x 20 25 mm thick ( as per manufacturers specifications ) , asperiso24346 ( en428 ) texture&design, top wear layer thickness 3.5 mm, with 3 mm under lay of foam with a direct laminated surface treated with aluminium oxide on top ofa high density fibre board with a density of 850 kg. / per mtr. having a click system tongue and groove joint to secure a long lasting joint. the planks are to be termite resistant and water protected with both side lamination, withpremiumfinish plank, glue freelocking system;2lock, with maximum floor surfacetemperature 27 c, with self –regulating under float heat system, with formaldehyde emission e1 as per en 13986, reaction to fire dfl as per en 13501 and100% recyclable with mini or maxi bevel lengthwise etc. complete. ( offices & conference room ) , kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) , providing & fixing 12mm thick x 100 mm highfirst quality solid teakwoodskirtingwherever necessary including melamine polish shade to be match with the same matching shadeofwoodenflooring &withveneershadetoallwood surfaceswith 6mm groove between skirting & gyp / veneer to t.w.frameworkort.w.panellingasperarchitectsdetail drawing & design etc. complete. , providingandfixingmachinecutmirrorpolishedblue pearlgranitestoneslabofrequiredsizeand20mm thick of approved quality , vein and colour for dado fixed on base plaster on 20mm thick cement mortar 1:4 including filling joint with neatcolouredcementslurry, curing, handpolishing, moulding, edgefinishing, andcleaningetc.complete. , providing&fixingvitrifiedtilesfortoiletdado of size 600x600 as per manufacturers specificationanyothersuitablesize approvedby architect andofapprovedcolourandshade finished, in approved pattern with 12mm thick backing coat of 1:4 cement plaster / mortar and neatcementfloatusingpolymerbasedtileadhesivesof approved quality including filling jointsto match the colour of dado curing, acid cleaning etc. complete. for toilet , italian marble cladding providing and fixing machine cut and mirror polished approved coloured italian marbleslabwithinlaysofapprovedsize, 20mm+2mm thk. of approved quality for required pattern on a bed of 1:4 cm25mmaveragethicknessincludingneatcement float, filling joints with neat coloured pigment , curing, polishingandcleaning, highglosstinoxidepolishwith italianpolishmachineetc. complete. , providingand constructinggranite kitchen platformwith fixing of quartz sink 600 mm x 450 mm size as per detailed drawing includingverticalbothsidepolishedgranite stone 19 to 22 mm thick double supports with kadappah base 35 to 40 mm thick and polished granite19 to 22mm ontop with side strips of granite at front and both sides of platform raised with two vertical granite supportsincluding cutting, opening asperarchitectsdetailsdrawing anddesign asdirectedby engineer in charge. for sink of required size in graniteetc. complete. ( rateexcludesquartzsink but includes rate for kadappah ) .only total surface ( plan ) area of platform to be measured , supply of quartz sink 600mm x 450 mm size including fixing the sink in position with waste coupling, bottle trap and any other fixtures all complete as per the specifications and directed by engineer in charge. , providing & fixing single piece rimless bowl for coupled wc with uf soft close slim seat cover, hinges, fixing accessories and accessories set, size : 380x660x850 mm, s trap 250 mm. as per approved sample. , providing & fixing soap dispenser metallic bottle. as per approved sample. , p&f soap dish holder.as per approved sample. , providing & fixing toilet paper holder with flap recessed type ( stainless steel ) . , p&f stainless steel surface mounted sanitary napkin disposal ( with flap ) of approved quality / quality. cabinet 18 8, type 304, stainless steel size 270mm ( l ) x 105mm ( w ) x 385mm ( d ) capacity: 4.6 litres equipped with full length stainless steel piano flap. as per approved sample. , paper towel dispenser. cabinet 18 8, type 304, size 265x90x365 stainless steel finish: stainless steel satin capacity: 450 c fold, 600 multifold. as per approved sample. , p & f stainless steel hand dryer of approved quality / quality. casing:stainless steel # 304 non magnetic, matt finish mounting :wall mounted operation :touch free infra red activation sensor range : 12 cm 15 cm hand dry time :less than 20 secs auto cutoff: 30 seconds motor:brush type, dual ball bearings speed:25, 000 rpm rated power :550 w ( no heating element ) current:2.5 a protection class :ip x 1 blowing volume : > 270 m3 / h air speed:95 m / s ( with speed controller ) as per approved sample. , modular cubicle based restrooms of stainless steel make with stainless steel hardware with locking arrangement and 1 spare lock each.handles and hinges to be included in the rate. measurement per cubicle. , p & f 1st quality wvc urinal ( is:2556 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc. complete. as per approved sample. , p & f 12mm thick toughened glass urinal partition with all type fitting. ( partition size 300mm x 1050 ) . as per approved sample. , p&f bevelled edge mirror / mirror with 25mm width teak wood lipping including melamine polish around of special glass of approved quality as per direction of engineer in charge complete with 6mm thick commercial ply basefixed to wooden screws & washers. ( size 600 x 450mm x 4 mm thick ) , false flooring providing and fixing cementitious access floor systems of preferred / standard quality confirming to en12825 or equivalent standards. the access floor system to be installed shall be of finished floor height of 450 mm from the existing floor level comprising of 600mm x 600mm cementitious square panels. the system will provide for suitable pedestal and under structure designed to withstand various static loads and rolling loads subjected to it in server / rack area. the entire access floor system will provide for adequate fire resistance, acoustic barrier and air leakage resistance. at least 4 nos. of lifting suction devices to be provided. the raised floor must be capable of withstanding a uniform distribution load of 1500kg / sq. mtr as per specification. it room ( a4 server ) , it room ( a2 & a3 server ) & power room , structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat and two coats of acrylic paint of approved quality for primer and paint all complete. , plain cement concrete m15 grade using graced stone aggregate of 20mm / 40mm max. size including consolidation using vibrator & needle if required finishing, curing, form work shuttering, centering etc. complete all as per specification and in quantity as & when required by the engineer in charge, , hexagon shape ceiling made out of folded aluminium. the hexagon shapeunits shall be in 6 sides customise size of each side 750mm and 1mm ( thick ) , non perforated aluminium. the ceiling hexagon units shall be installed at distance of 300mm one hexagon to second hexagon. the hexagon units are then attached to baffle ceiling ( included in scope of this item ) by slotted cleats and screwing arrangement alongwith bolted brackets attached to ceiling by baffle splice and carrier splice combination with hangers and screw bolting to ceiling which is included in the scope. , providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminium sheet having electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing & supplying stainless steelss 202and aboveperforated type cylindricaldustbinof230mmdia&400mmheightas approved by consultant. . , providingandapplyingthreecoatsofmelaminepolishof requiredfinishtowoodworkbyspraymachineincluding knottingandpreparingthesurfacebyscrapping, applying wood filler, scaffolding if required etc. .complete , providing and applying first quality metallic transparent pu coating of approved quality and shadeon plywoodor veneer wherever required with sand papering & cleaning the surface, applying one coat of primer and lambi / putty including wood filler to full surface 3 times, thereafter polishing the surface in twofinishingcoatsoverbaseprimercoattoachieveeven finish. all complete as per instructions of engineer in charge. etc. complete , supplying&installingsunscreenperforatedrollerblind optima series basket 125 tex with fabric specification of ( fabric composition polyester 22 % and pvc 78 % , openness factor 5%, thickness 0.68mm + / 5%, weight perm2 480.00gsm, yarnscountinwrap / weft / cm19 / 18+ / 5%, fireresistance fr ( usa ) kfi ( korea ) , tearresistance wrap11.9 dan+ / 5%, weft 150 dan+ / 5%, colour fastness 6 7 / 8 ( whitecolourbase ) , artificiallightxenonlamp, uv resistance min 3 ( white colour base ) , width 2.5m & 3 m the roller mechanism shall be a moulded unit made from engineering gradeplastic polymerwith pvcspring support. thefabricshallbeattachedtotherollertubewithhigh quality self adhesive tape with manual operation . the total area of opening covered will be measured. , blackout providing, supplying&installingroller blindsinseclusionserieswithspecificationof basic material 1005polyester, fabricwidth200 / 250cm, fabric weight 20 / 295g / sq.m. thickness 0.50mm finishing blackout fabric, reverse&frontsidepigmentcolourcoatedcolour fastness>5 / 6, rubbing fastness depending on colour, shrinkage wrap:<0.5%withapprovedshadefabric, ( forexternalwindows ) comprisingofpolymercoatedfibre fabric.therollermechanismshallbeamouldedunitmade fromengineeringgradeplasticpolymerwithpvcspring support . the fabric shall be attached to the roller tube with high quality selfadhesive strip.the total area of opening covered will be measured. , supply & fixing rigid autoglow photo luminescent signages, on glowinthedarkrigidsheetwithhighintensityluminous propertiesenclosedintransparentweatherproofuv stabilized coated sheet with uv screen printing by imported ink thickness of photo luminescent sheet 1mm, glow should be visible for 24 hours in total darkness. these signs adheres to pspaclassadin67510part2, bs5499 1, nfpa101etc. complete. any and all sizes below 2ft*2ft. , providing and fixing gypsum cove as per architects drawing between ceiling & wall / column with gi frame support, finished from the top & sides by 12mm thick gypboard including making necessaryhousing for concealed lightfittings, speakers, etc.completeasperarchitectsdetailed drawing and design and as directed with necessary scaffolding etc. complete. , officetable ( maincabintable ) providingandfixing table & pedestal with 3 drawers ( size 400 x450x725 ) to be made out of 19mm thk bwp ( is710 ) marine ply cladded with 4mmthkveneer&finishedwiththreecoatsofmelamine fromoutside&0.8mmthklaminatefinishedfrominside. onlytabletopedgefinishedwithpostform&otheredges finishedinpvcedgebinding.tabletop46mmthickness inside finished with 0.8mm thk laminate.pedestal drawerto be operate with telescopic drawer channel as per detail drawing ) . complete with all necessary hardware & fixture. note : all furniture to be made out ofcalibrated plywood ( is : 710 ) bwpall internal & external surfaces of plywood finishedwithlaminateandveneerrespectively.all hardware complete as perdetaileddrawing & instructions directedbyengineerincharge.includingloading, unloading, transportation, installation. with1yearwarranty. rate to include wire manager system of approved quality size: 1800 x 900 x 750 mm , thrive + with head rest chair. thrive plus high back with headrest and coat hanger .thrive plus high back with headrest and coat hanger generally size in 75 cm * 75 cm height 115 130. , bravo visitor chairs width 61.4cm * depth 64.5cm*height 89.5cm * seat height 46.5cm , sidestorage ( dgmcabin ) providingandfixingside storageunittobemadeoutof19 / 12mmthkbwp ( is710 ) marineplycladdedwith4mmthkveneer&finishedwith melamine from outside & 0.8mm thk laminate finished from inside. only side storage top edge finished with post form & otheredgesfinishedinpvcedgebinding.tabletopinside finishedwith0.8mmthklaminate. complete with all necessary hardware & fixture. note : all furniture to be made out ofcalibrated plywood ( is : 710 ) bwp all internal & external surfaces of plywood finished with laminate and veneer . all hardwarecomplete as per detailed drawing & instructions directed by engineer incharge.includingloading, unloading, transportation, installation. with 1 year warranty.size: 1050 x 400 x 750mm , workstation providing&supplyingat site , workstation comprising of modular 1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge.with1 yearwarranty. ratetoincludewire managersystemofapprovedquality. size : 1350 / 1350 x 600 x 750 / 1200mm , sharing workstation providing & supplying at site , workstation comprising of modular 1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture.. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge with 1 year warranty. rate to include wire managersystemofapprovedquality. size: 1200 x 600 x 750 / 1200. , nonsharingworkstation providing& supplyingatsite, workstationcomprisingofmodular 1200mmheight, 60mmthickness partitionsystemwith powder coated aluminium framing with powder coated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate complete, asperdetaileddrawing&instructionsengineerin charge with 1 year warranty. rate to include wire manager system of approved quality.size: 1200 x 600 x 750 / 1200. , cubicletable cubicletableproviding& supplyingatsite, comprisingofmodular1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is : 710 ) bwp, allinternal & external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge.with 1 year warranty. rate to include wire managersystemofapprovedquality. size: 1800 / 1800 x 600 x 750 / 1200 / 700 x 1800 , conferencetable providing and fixing conference table to be made out of 19mm x 2 = 38mm top / / 12mm thk boxing supports of bwp ( is710 ) marine plycladded with 4mmthk veneer&finishedwith melamine from outside & 0.8mm thk laminate finished from inside. all expose surfaces to be 4mm veneer with 48x48mmedgelipping fortabletop&100x 25mm teakwoodedgelippingforsupportingboxingfinish. completewithallnecessaryhardware& fixture. provision for necessary wire management and 6 nosofdeskportof8 moduleas directed ( without electrical ) .complete with all necessary hardware & fixture. etched glass to be installed if required. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfacesofplywoodfinishedwith4mmveneerand3 coatsofp.u.coating, allhardware complete, asper detailed drawing & instructions directed by engineer in charge.includingloading, unloading, transportation, installation. with1yearwarranty.ratetoincludeall provisionofinstallationconcealedspeakersystemand 12mmthickbwpmarine plyapronwith4mmthick veneerfinishonbothsideand20x12mmteakwood edgelipping.ratetoincludewiremanagersystemof approved quality. size: 5500 x 1200 x 750. , meeting table providing and fixing meeting table tobemadeoutof19mmplus12mmtabletopand 12mmthickboxingsupportsbwp ( is710 ) marineply cladded with 4mm thk veneer & finished with melamine from outside & 0.8mm thk laminate finished from rear side.all expose surfacesto be 4mmveneer with37 x 37mmedgelippingfortabletop.completewithall necessaryhardware&fixture. provisionfornecessary wire management and deskport of 8 module as directed ( withoutelectrical ) .completewithallnecessary hardware & fixture. note:.allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate and veneer of . all hardware , complete as per detailed drawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, installation. with 1 yearwarranty.rate to includewiremanagersystemof approved quality. size:2700 x1050 x 750.mm / 600mm dia , cafeteriatable cafeteriatable providing& supplyingatsite31mmthick cafeteriatable comprisingof 25mmthickbwpgrademarineply tabletopwith12mmthk corianfinish &37x 12mmcorianedgebindingthetabletopissupported with s.s.304gradebaseunderstructurecomprising of 75mm diapipe&4pronged withpvcleveller. complete with all necessary hardware & fixture. size: 900 x 900 x 750.mm / 900 x 2970mm , receptiontable providing&supplyingatsite custom made reception table & apron in 19mm marine ply construction inclusive of support framing, table, counter top & drawer box with key board tray asper architect drawing &design. rate to include 19mm thick italian marblecounter top & edging62 x 19mminclusiveofedgepolishing&finishing.basic rate of italian marble rs.800 / sqft. facia to be finish with 12mm thick corian with polishing & buffing, edge bindingwith12mmcorian.concealedledlighting strips with drivers to be installed in pelmet ( led strip is19mmx 12mmwithpolycarbonatecover.all other surfacesinternal&externaltobefinishwithveneer inclusiveofteakwoodedgelippingof10mm thickness. provisionfornecessarywiremanagementas directed ( withoutelectrical ) .completewithall necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate . all hardware complete, as perdetaileddrawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, etc. complete. size: 1800 x 750 x 1050mm ht , medium ht storage providing & supplying at site, med ht storage unit 18 mmthick top, all sides, shelf, bottom made out of calibrated plywood ( is : 710 ) bwp with p / f 0.6mm laminate, other edges finished with 2.0 mm thick pvc edgeband for exposed edges & 0.8 mm thick for non exposed edges t.complete as per architects detailed note :all furniture to be made out ofcalibrated plywood ( is : 710 ) bwp, all internal & external surfaces of plywood finished with laminate . all hardwarecomplete, as per detailed drawing & instructions directed by engineer in charge. including loading, unloading, transportation, installation., with 1 year warranty. size : 900 x 450 x1200mm , lockers providing & supplying at site, locker storage unitof8compartments18mm thicktop, allsides, shelf, bottom& shutters made out of calibrated plywood ( is:710 ) bwpwithp / f0.6mmlaminate, other edges finished with 2.0mm thick pvc edgeband forexposededges&0.8mmthickfornonexposed edges complete, as per architects detailed note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate . all hardware complete, as perdetaileddrawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, installation, with 1 year warranty. rate to include locking arrangement with hinges, handles&hardware.size :1050x450x 2400mm. , revolving type chair with wheels : seat assembly : the cushioned seat is made of injection moulded plastic outer & inner. plastic inner is upholsteredwithleatherette andmouldedhighresilience ( hr ) polyurethane foam ofdensity45±2 kg / m³ and hardness load 16 ± 2 kgf as per is:7888 for 25% compression * seat size : 47.0 cm ( w ) x 48.0 cm ( d ) backassembly: thecushionedbackismadeofpu foam with insitu moulded ms moulded e.r.w.round tube of size1.9±0.03cm x0.16±0.0128cm.itupholsteredwith leatherette.*mid back size : 47.7 cm ( w ) x 60.1cm ( d ) armrests: thearmresttopismouldedfrom polyurethane ( pu ) and mounted on to a drop lift adjustable type tubular armrest support made ofø 3.81 ± 0.03 cmx 0.2 ± 0.01cm thk m.s.e.r.wtube having chrome plated finish . thearmrestheightadjustableupto6.5±0.5cm in5 steps. seatdepthadjustment: seatdepthadjustmentis integrated in the seat through a sliding mechanism. seat depth adjustmentrangeisof6.0±0.5cm.adjustable back support : back frame is connected to the up / dn mechanismhousedinplastictspine.itcanbeadjustedin the range of 7.42 ± 0.5 cm for the comfortable back support to suit individual need .active bio synchro mechanism: the adjustable tilting mechanism is designedwiththefollowing features: • 360°revolving type . djustment : the pneumatic height. adjustment has anadjustment stroke of 10.0 ± 0.3 cm . , revolving type chair with wheels: seat / back assembly : the seat & backis made up of 1.2±0.1cmthk. hotpressedplywoodmeasuredasperqa method describedin qcp olta pl14 18:upholstered with synthetic leather over moduled high resilience polyurethane foam. • high back size : 51.8 cm ( w ) x 75.2cm ( h ) • seat size : 49.0 cm ( w ) x 48.8 cm ( d ) high resilience ( hr ) polyurethane foam : the hr polyurethanefoam ismoduledwithdensity=55+ / 2 kg / m³andhardnessload16±2 kgfasis:7888for25% compression. armrests : the adjustable armrest is designedwiththefollowing features • up down adjustment 8 steps ( 8.0 ± 0.5cm range ) • height adjustable armreststructurewhichischromeplatedandfittedwithan armrest top • fixed armrests topispu moulded over metal insert. backheightadjustibality: backcanbe adjusted in 5 positions by manually .stroke of height adjustable spine is 7cm.back height adjustability is applicable for high back & mid back chairs .pneumatic height adjustment : the pneumatic height. adjustment has anadjustment stroke of 10.0 ± 0.3 cm . , bean bagchairs xxl size of approved colour, shade and material as per the direction of engineer in charge , providing, fixing, installing & putting in place& in proper condition, as per layout & as per direction of the engineer in charge.seating asperfollowingdetails. basicratefor fabric upholstery rs 450 / .per mtr: 1seater sofa size: ( 860w x 905d x 855h ) seatfoam:theseatismadeupofpufoamindensity 28±2 kg / cu. mtr with an additional top layer of supersoft pu foam in density 32±2 kg / cu, upholstered with fabric or leatherette. backfoam:thebackismadeupofpufoamdensity 28±2kg / cu, mtrwithtwoadditionaltoplayerofsupersoft foam ofdensity 32±2kg / cu, mtr, upholstered withfabric or leatherette. undersructure:understructureismade upof 1.2±0.1 cm. thick hot pressed plywood ( moisture resistance & termite proof as per is:303 ) & pinewood of cross sections devoid of majorknots&surfacedefects.6nosperseat&3.8mm dia zigzagspringassemblyismountedoverunderstructurefor cushioning purpose. leg assembly: it is a welded assembly made in stainless steel ( grade ss 202 ) tube & plate with plastic endcap the product to be tested and passed the quality standards as laid down under iso 9001, 1s014001, iso18001, ohsas andbifmacertificationsforqualityassurance.ithasa green assurance card validated by tuv india. location staff & wherever required, , electrical , dg set , supply , installation, testing & commisioning of diesel generating ( d.g. ) set with class g3 governing ( 40% step load ) , alternator of 325 kva output at 0.8 pf continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 v, 50c / s, radiator cooled, multi cylinder diesel engine at 1500 rpm , seperately excited amg having class h, spdp alternator ( with battery charging generator ) , with static avr + / 1% & thd<3%, running at 1500 rpm. both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having engine & generator protection ( including ref & rpr ) / parameter display / operator interface / power command 3.3 control system / amf panel / synchronization / dedicated earthing system / rs 485 modbus connectivity, etc. the complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 db at 1 meter, made of 16 / 14 swg crca sheet, complete with first filling of lube oil / diesel / coolant & fuel hoses, battery, 990 liter external fuel tank, residential silencers, mounted on plinth & obtaining necessary approval from electrical inspector. a. amf panel comprising of suitable rating fp edo acb for mains and d.g., auto / manual selector switch, engine start / stop push button, indication lamps, voltmeter / ammeter / kwh meter / rpm meter / hour meter / announciator / relays / battery charger / dc ammeter / voltmeter, etc. b ) exhaust piping to be raised upto terace level of nearest building. c ) power / control cabling, terminations, etc. d ) 990 ltr. capacity external diesel tanke ) . height of stack to be maintained as= height of building + 0.2 * vkva . f ) factory testing to be carried out in present of actrec engineering before despatch of equipments. , supply, installation, testing and commissioning of following all indoor panels comprising below points. 1 ) panels shall be fabricated out of 16 / 14 swg crca sheet steel, with necessory structural supports in form of structural steel sections. 2 ) floor mounted, ip 52 degree protection, top bus duct or cable entry as per the case & top cable exitsteel, 2mmframe, 1.6 mm compartments & tank process treated & 2 times epoxy painted. 3 ) the panel shall be compartmental, form 3b type, with suitable size of bus bar and separate cable and busbar chambers. 4 ) proper gland size holes to be provided bythe manufacturer with proper sticker and danger sign on all sides of panel. 5 ) the cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination. 6 ) current density 1.2 ampere / 1 sq.mm for copper and 0.8 ampere / 1 sqmm for aluminium ( is 8623 for factory built assembly ) . specification of copper for copper bush bar c11000 electrolytic tough pitch ( etp ) . 7 ) earthing terminal.8 ) fault level 50ka / sec.9 ) panel inside illumination to be provided10 ) receptacles , space heater provided as per standard. 11 ) epoxy paint colour type ral 7032 to be use. , l.t. panel 1 & 2 ( as per sld attached ) , office panel ( as per sld attached ) , utility panel 1 & 2 ( as per sld attached ) , 30kva ups o / p panel ( as per sld attached ) , pdu 1 & 2 ( as per sld attached ) , 5kva ups o / p db for emergrncy lighting and ibms load. ( as per sld attached ) , automatic changeover switch ( ats ) , 32a 4p automatic changeover switch ( ats ) , ups system , supply , installation, testing & commisioning of 80kva online, pure sine wave modular ups system, 3 phase input and 3 phase output with upf, 0.96% efficiency, igbt based rectifier technology, isolation transformer, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , supply , installation, testing & commisioning of 30kva online, pure sine wave modular ups system, 3 phase input and 3 phase output with upf, 0.96% efficiency, igbt based rectifier technology, isolation transformer, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , supply , installation, testing & commisioning of 5kva online, pure sine wave modular ups system, 1 phase input and 1 phase output with upf, 0.96% efficiency, igbt based rectifier technology, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , distribution boards , supply and fixing of tpn, double door power distribution board having 63 amps tpn mcb 1 no. / / / 40 amps , 10ka , dp elcb ( 30 ma ) 3 nos / / / 20 / 32 amps sp mcb ( 8ways ) 24 nos. ip 55, ik 08, , supply and fixing of tpn, double door lighting distribution board having 63 amps tpn mcb 1 no. / / / 40 amps, 10ka , dp elcb ( 30 ma ) 3 nos / / / 10 amps sp mcb ( 12ways ) 36 nos.ip 55 , ik 08 , supply and fixing of spn, double door power distribution board having 32amps , 10ka dp elmcb 1 no. / / / 16 amps , 10ka dp mcb 6 nos. , ip 55 , ik 08 , supply and fixing of spn, double door lighting distribution board having 16amps 10ka , dp elmcb 1 no. / / / 10 amps , 10ka sp mcb 6 nos., ip 55 , ik 08 , mains wiring , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. , 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , point wiring , wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for plug on board, switch with multi socket concealed type and copper wiring, earthing and with modular accessories. , providing fan regulator on board with modular switch and regulator. , switches, sockets & accessorie , supplying and fixing of 3 / 4 module switch box with modular plate including connections but excluding modular plate etc. as required. , 15 amps switch , 5pin 5 / 15 amp socket outlet , 32a 3p+n+e socket with plug ac powerenclosure and mcb , 16a 1p+n+e mobile socket with plug ac power , lighting fixtures / exhaust fans / ceiling fans , supplying and erecting of recessed type square shaped crca / die cast aluminum powder coated housing led panel light 600x600mm of premium range suitable for upto 36 w with provision for plane front frame with translucent cover fixed to the housing complete.lumens output >3200 , cri more than 80 , cct 6500k, thd <10% , supplying and erecting led square / circular 13 to 18 w premium range down lighter having pressure die cast aluminum housing with white front frame with opal translucent cover with provision for spring loaded mounting clips complete. lumens output 900 / 935 / 980 , cri more than 85 , cct 3000k to 6000k, thd <10% , supply and erecting of box type led light fitting with 1 x22w led tube light complete with all accessories. , standerd 230v ceiling mounted day light cum occupancy sensor. , supply and fixing of call bell with all accessories. , supply and fixing of 225mm sweep exhaust fans. , supply and fixing of 1200mm sweep ceiling fans. , cable tray , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 300 mm width & 50 mm height complete with necessary coupler plates, support & hardware in approved manner.coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 500 mm width & 75 mm height complete with necessary coupler plates, support & hardware in approved manner. coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 750mm width & 75 mm height complete with necessary coupler plates, support & hardware in approved manner.coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , lt cables , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx300 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx185sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx150sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx70 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx50 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx35 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx25 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx70sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx35 sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx10 sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 3cx6 sqmm copper conductoron wall / in provided tray as per instructions. , supply and fixing of end termination with brass double compression gland andlugs of copperor aluminiumor bi metallic lugswhich are suitable at sitefor following size of frls insulated and xlpe aluminium conductor cable of 1.1 kv grade as required. , 3.5c x 300 sq.mm. , 3.5c x 185 sq.mm. , 3.5c x 150sq.mm. , 3.5c x 70sq.mm. , 3.5c x 50sq.mm. , 3.5c x 35 sq.mm. , 3.5c x 25 sq.mm. , 1c x 70 sq.mm. , 1c x 35 sq.mm. , 1c x 10 sq.mm. , 3c x 6 sq.mm. , earthing , supply and fixing of 50 mm x 6 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 40 mm x 5 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 25 mm x 3 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 8 swg copper wire on surface or in cable tray for connections etc as required. , tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like cole, charcoal, salt, brass nut bolts & washers, watering arrangements, gi pipe ( b class ) , concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. the chamber cover & plate shall be of heavy duty hinged type & it shall weigh approx. 65 to 75 kgs. plastering shall be done both inside & out side.the measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by engg in charge. , chemical earthing / maintenance free earthpits having better earth resistance value. , addressable fire alarm systems & detection systems : , supply , installation , testing and commissioning of addressable automatic dual led smoke detector with two integrated light scattering smoke sensors using leds with different colors / wavelengths ( blue / infrared ) to avoid false alarm & should comply to test fire 1, including mounting base with led, drift compensation feature & automatic addressing.high resistance to electromagnetic effects in accordance with efsg agreement efsg / f / 97 / 005 shall be en54 / vds / ul certification.2isolators ( one for incoming & one for outgoing line ) integrated in detector for maintaining operational availability of all elements in the loop , even in the evennt of a short circuit, bosch model fap 0 420 or equivalent. , sitc of addressable thermal detector including mounting base with led..etc complete as required with inbuilt isolator.temprature sessor triggers@ 54deg c or 69 deg c & drift compensation feature.shall have ul / vds certification bosch model fah t 420. , supply, installation, testing & commissioning of addressable, ul listed, duct smoke detector comprisingsplash & hose proof, uv resistant, housing assembly with sampling tubes & photoelectric detector with heat element ( 57deg c ) , suitable for air speeds of 100 4000 fpm, loop powered, class a wired, low profile, temper resistant, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , wiring box, in / out cable glands. , supply, installation, testing & commissioning of addressable, ul listed, control module for switching power supply to hooter & strobe, loop powered, class a wired, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , suitable for surface / recess installation, wiring box, in / out cable glands. , supply, installation, testing & commissioning of addressable, ul listed, control module with relay for ahu / damper / switchgear operation, loop powered, class a wired, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , suitable for surface / recess installation, wiring box, in / out cable glands. , supply at site, installing in proper position testing and commissioning of 2 core x 1.5 sqmm frls armouredcopper conductor cable of approved quality all complete as required and as per final direction. , removing and refixing of detectors, isolators, monitor moduls, control moduls, etc. , supply and fixing of junction boxes with cable glands, lugs, etc. , fire suppression system comprising of following , novec 1230 based fire suppression system comprising of the following items: , sitc of ccoe approved ul listed seamless novec 1230 cylinder and valve assembly, 120 ltrs. capacity, oem factory filled with novec 1230 suppression liquid ( item no. 2 ) , pressurised to 25 / 42 bar. along with hydraulic flow calculations for the suppression areas, and vetting of the software results from the oem factory engineer. , sitc of ccoe approved ul listed seamless novec 1230 cylinder and valve assembly, 80 ltrs. capacity, oem factory filled with novec 1230 suppression liquid ( item no. 2 ) , pressurised to 25 / 42 bar. along with hydraulic flow calculations for the suppression areas, and vetting of the software results from the oem factory engineer. , sitc of novec 1230 fire protection fluid, oem factory filled per kgs. , sitc of tank bracket assembly complete with c channel stand and supports for above cylinder. the price shall include ms fabricated floor supported cylinder support stand, wherever required. complete with 1 coat of primer and 2 coat of black enamel paint. ( refer drawing for cylinder locations ) . , sitc of ul listed discharge hose withmanifold check valve ( check valve if more than one cylinder in bank ) for above cyilnders, complete with listed adapters & accesories as required. , sitc of ul listed electrical actuator for master cylinder. , sitc oful listed local manual actuator , sitc oful listed pneumatic actuator shipping assembly with actuation hose & elbow. , sitc oful listednozzles, 360 deg / 180 deg throw, selection as per approved hydraulic flow calculations. , sitc of warning sign board with marking gas discharge. do not enter. shall operate on 24 v dc, driven through gas release panel. ( for use outside room ) , sitc of warning sign board with marking gas discharge. evacuate immediately. shall operate on 24 v dc, driven through gas release panel. ( for use inside room ) , sitc of ul listed cylinder low pressure switch , sitc of ul listed cylinder discharge pressure switch, shall be install on the novec piping after discharge hose. , sitc of novec piping & manifold as required, sch 40; astm a106 gr b, as per flow calculations for the specific hazard volume and stand to hold, position & support the manifold and piping properly. pressure testing for piping with nitrogen as per nfpa 2001. , supply installation testing & commissioning oful listed single zone gas release panel facility to connect manual abort / release switches. the panel shall provide potential free contacts for first knock, second knock, trouble / fault status. the panel shall be complete with red colour housing, monitored power supply unit, battery charger & batteries. , supply installation testing & commissioning ofmanual abort stations, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. the abort will be monitored simultaneously by fire alarm or bms system. , supply installation testing & commissioning of manual release stations, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. the release switch will be monitored simultaneously by fire alarm or bms system. , towards conducting room integrity test : door fan test to meet the requirements of the nfpa 2001, and predicting the efficacy of the protected area enclosure from the perspective of fire suppression. , supply installation of 2 core x 1.5 mm2, multistranded at copper, frls armoured cable, red in colour. the cable shall belaid on surface with gi saddle spacers every 0.3 meters. complete with gi junction box, lugs, cable compression glands, cable tags and ferruling. , public address system , supply, installation, testing and commssioining offollowing items , ul listed, 6 watt ceiling mount speaker with junction box for ceiling mount , goosneck micro phone , cd / mp3 player , 6 zone selection panel for pa announcement , rack to mount amplifier, cd player and console , 2 core 1 sq.mm copper conducter cable with 20 mm dia pvc conduits , lannetwork , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed pvc conduit as required. , supplying, installing & testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. , supplying and fixing following 3 module, gi box along with modular base & cover plate as required. , supplying and fixing 1 meter length, utp patch cord of cat 6 type in position as per requirement. , supplying and fixing 24 port patch panel with tool less keystone jacks in provided u rack complete as per requirement. , supply & fixing of 25mm pvc conduit with accessaries. , sitc of it rack 19 wall mounted president quality rack 15u ( double section ) with acrylic glass door with the accessories [ two fan position tray with two 90 cfm fans ( ac 230v ) , 3 horizontal cable manager 3nos, ac power panel strip with 5 x 5 amp sockets , fuse and on / off switch, 1 packet mounting hardware , supplying and fixing 7 ft length, utp patch cord of cat 6 type in position as per requirement for end point device ( pc / laptop etc ) , sitc of lazr speed 300 fiber, 6 core indoor application, multimode, to be laid through conduit and flexible with all the connectors, couplers, pigtels, lius at both end , telephonenetwork , supplying & erecting jelly filled armoured telephone cable 20 pair with 0.5 mm dia. , supplying, erecting & commissioning of telephone tag block with crone module suitable for 20 pairs as required. , supplying and fixing of rj 11 / rj 45 modular telephone socket with g.i. switch box, modular plate including connections as required. , supplying, installing, testing & commissioning approved type push button telephone instrument desk top / wall mount unit as per specification in approved manner. ( panasonic model no kx ts 580 ) , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed pvc conduit as required for ip phone. , ip telephone instrument. , 24 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24x10 / 100 / 1000poebase tports, 2fixedsfp ( 1g ) withinternalpowersupply ( 192wpoe budget ) . , 8 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24x10 / 100 / 1000poebase tports, 2fixedsfp ( 1g ) withinternalpowersupply ( 192wpoe budget ) . , 12u wall mounted double section rack with acrylic glass door having 2 nos. 90 cfm fans, cable managers, 5a sockets, fuse, on / off switch, 1 packet mounting hardware, etc. , supply & fixing of cat 6 , 24 port patch panel loaded. , supply & fixing of 2 mtr. patch cord. , supply & fixing of 25mm pvc conduit with accessaries. , cctv system , supply, installation, testing and comissioningof the following equipment for cctv system , indoorip base day & night, 2mp hd resolution with ir illumination, varifocal lens cmos, resolution 1920x1080p @ 25 fps, widedynamicrange @ 90 db, wdr ccd dome cameras, 2.8mm to 12mm ir lense, min. 15mtr coverage, sd / sdhc memory card slot., camera should be poe enabled. the camera should be onvif compliant. , indoorip base day & night, fixed dome cameras, 2.8 mm ir lens, minimum 110 degree of horizontal field of view, resolution 1920 x 1080p @ 25 fps, 10 mtr coverage, camera should be poe enabled. the camera should be onvif compliant. , supply, installation, testing and commissioning of 16 port 10 / 100t managed poe access switch with 2 sfp uplinks ( layer 2 ) . configuration to be decided by vendor base on real time image transmission from camera / encoder to server. all the switches should be in racks. , supply, installation, testing and commissioning of 16 ports 10 / 100 / 1000t managed poe switch ( layer 3 ) along with sfp module. configuration to be decided by vendor base on real time image transmission from camera / encoder to server. all the switches should be in racks. , nvr / nas & vms , supply, installation, connfiguration, testing & commissioning of video networked recorder ( nvr ) of suitable channel with 30 days motion based storage at 20 fps, along with vedio management software ( vms ) along with required camera license. , supply , installation , testing and commisioing ofcat 6 cable for power / data cabling from camera to switchwith 25 mm pvc conduit. , supply, installation, testing and commissioning of color high resolution led tv comprising of 42 display, full hd, hdmi input provision; complete with all supports and accessories. , sitc of 6pair multimode fiber optical cable with termination all necessary accessories and termination as required. , cat 6 iowith back box & surface plate , cat 6 patch cords , access control system comprising of following , supplying, installing, testing & commissioning of the access control system consisting of the following: , supply , installation, testing and commissioning of 4 reader ip based door controller for controlling the above card readers as per specification mentioned including all accessories.max. 4 reader combition ( tenderer to mention quantity of controllers based on their system. ) system should have capability to expand up toadditional 100 doors in future. , supply , installation, testing and commissioning of 2 reader ip based door controller for controlling the above card readers as per specification mentioned including all accessories.max. 4 reader combition ( tenderer to mention quantity of controllers based on their system. ) system should have capability to expand up toadditional 100 doors in future. , sitc of biometric fingerprint + pinpadreader , supply , installation, testing & commissioning of proximity card readers as per specification suitable for mounting on metal surface / metal frames or wooden frames wall or as required based on site conditions including all accessories , sitc of panic bar with egress switch , supply , installation, testing and commissioning of smart cards as per specification. , sitc of break glass unit for access doors , sitc of single leaf electromagnet door holder ( fail safe type ) of 600 lb holding force , sitc of double leaf electromagnet door holder ( fail safe type ) of 600 lb holding force , sitc of door contact sensor , sitc oftime, attendance and visitor management software for access control with seamless integration with bms module, visitor management module and time and attendance module as per the specifications. software shall be capable of handelling additional 10 nos. of access readers. , supply , installation , testing and commisioing ofclient workstation processor intel core i 7 os genuine windows xp / 7prof colour monitor 21 flat panel lcd / led monitor ram 16 gb ddr3 sdram memory 1 tb hdd a4 laser jet printer network: 100 / 1000 mb ethernet network card resolution support: 1024 by 768; 1280 by 1024; 2048 by 768; 2560 by 1024 , cables & accessories for acs system , supply , laying , testing and commissioning of the following cables signal & communication cablesfor security access control, alarm monitoring system with all accessories including glanding and termination. , 6 cx 1sqmmshielded armouredsheilded cable , 4cx 1sqmmshielded armouredsheilded cable , 2cx 1sqmmshielded armouredsheilded cable , cat 6 cable for network controllers with 25 mm pvc conduit , building management system comprising of following: , the rate of each item of work for bas shall also include the following : 1. all materials, fixing materials, accessories, appliances, tools and equipment. 2. approvedcoverplates for inspection, junctionandoutlet boxes. 3. 2 mm thick outlet boxes and junction boxes. 4. all fixing accessories such as clips, nails, screws etc. 5. providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed cable work. 6. embeddingcablesand accessories inwall, floorsetc.duringconstruction and / or cutting chases and makinggood as in the case of all concealed cables work. 7. testing and commissioning of each device as per approveddesign concept , sitc ofduel core2 quad, 80gb hdd, 2ghz processor, 8gb ram, 52x cd rom drive 1.44 fdd, 17 colour monitor, microsoft bus mouse, 2 serial, 1 parallel port & windows xp operating system , sitc of colour inkjet printer , supply of necessary software packages containing building management & control software programmes with dynamic graphics interfaces , software and hardware required for integration of following third party system with bms , energy meters 5 nos. , ups 4 nos. , dg ( 2 nos ) & transformer ( 1 no. ) , cooling unit8 nos. , pdu 2 nos. , supply, installation, testing & commissioning of stand alone, intelligent, ul listed, interoperable ddc . , ddc controller for monitoring as per io summary , room temperature cum rh sensor , room temperature sensor , outside temperature and rh sensor , hydrogen sensor , wi fi modem for tap off box meters data connectivity. , signal cable 2 core 1.5 sq.mm pvc insulated cu armoured cable , communication cabling ( cat 6 ) for bms in pvc conduit , supply , installation , testing and comissioning of 16 port unmanaged network poe switch with accessories. , rodent repellent system comprising of following: , digital master console catering lp 12 satellites for rodent repellent system , satellites ( streem ) , wall mount bracket , 2 core 1 sq.mm cu. flexible shielded cable bundle ( 300 yards ) with 20mm pvc conduit , rrp software , water leak detection ( wld ) system: , sitc of water leak detection panel with modbus connectivity ( for all data center server area , ups locations and electrical control rooms ) , sitc of water leak detection module , water leak detection cable sensor , electronic hooter , 2 core x 1.5 sqmm frls armoured copper cableas per technical specification , miscellaneous items , 150x150x3mm danger notice board & 415 enameled danger board , 150x150x3mm danger notice board & 11kv enameled danger board , shock treatment chart with frame in local & english language , first aid medical box , supplyandinstallationof9 kgcapacityco2 typefire extinguishers conforming to is : 2171 , abc type – manual fire extinguishers with 6kgs. , providing of set of 4 nos.9.5 litre capacity g.i. buckets painted in post office red colour with prior coat of red oxide paint and written with white paint fire and , mounted on ms angle iron frame with bracket of appropriate size and capacity including , 1000 x1000 mm wide 2.5mm thick rubber matting suitable for 1100 grade , providing pair of duly tested rubber hand gloves as per is:340715 suitable for working on 11kv and 415v supply. , 50mm size pvc flexible conduit , 25mm size pvc flexible conduit , 50mm size pvc rigid conduit with accessories , 1 year warranty is included in the above items. cmc rate ( electrical components ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to six years without any escalation clause , hvac , variable refrigerant volume ( vrv ) , sitc of variable refrigerant volume modular type air conditioning equipment complete with indoor and out door units with central control system unit shall have central controller for controlling all the indoor and outdoor units and should be capable of integration with the computer system based building management system of hvac , outdoor unit , supply installation, testing & commissioning of modular type variable refrigerant flow / variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor ( s ) , minimum two compressors for above 14hp modules, microprocessor based controller , top discharge type condensing unit ( s ) , with r410a refrigerant, vibration isolators, with suitable foundation etc. complete as required. the unit shall deliver the rated capacity at ahri condition sand work even at 50°c ambient temperature without tripping. the unit shall be suitable to work on 400v+ / 10%, 3phase, 50hz ac power supply. the unit shall be filled with first charge of the refrigerant and ready for use as required. the cop at ahri conditions shall not be less than 3.1 and ieer not less than 6.5 , system 1 : 18 hp ( cold type ) , system 2 : 10 hp ( cold type ) ( 2w+1s ) , indoor units ( vrv / vrf compitable ) , supply, installation, testing and commissioning of following minimum capacity 4 way flow vrv / vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230v±10%, 50hz ac supply, complete, asr equired. the unit shall have automatic force shut down provision in case of fire on receiving signal from bms system.the cooling capacity of indoor unit wil be at air inlet conditions of 27 degreec db and 19 degree c wb temperature. , cassette unit with inbuilt drain pump , 2.8 tr , 2.4 tr , 1.6 tr , supply, installation, testing and commissioning of following minimum capacity vrv / vrf high wall type indoor unit equipped with synthetic washable media pre filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230v±10%, 50hz, single phase ac supply, complete as required. the unit shall have automatic force shut down provision incase of fire on receiving signal from bms system. the cooling capacity of indoor unit will beat air inlet conditions of 27 degree c db and 19 degree c wb temperature. , 2 tr , 1.65 tr , 0.8 tr , floor mounted ahu vertical / horizotal , supply, installation, testing & commissioning of double skin floor mounted horizontal / vertical ahu having 50 mm sandwiched puf insulation ( 0.80 mm thk inner skin & 0.80 mm thk outer plasticized gi ) . it shall have pre filter ( 90% down to 10 micron ) of washable type > 6row vrv / vrf dx cooling coil having 12 13 fpi and anti corrosion coatingfins with face velocity of 500 fpm > didw kruger quality backward curved fan with tefc squirrel cage induction motor with drive set. other accessories like inspection door, vibration isolator, limit switch, marine light, outlet mouth damper for supply to be provided. insulated ss 18g drain pan with 19mm thich class o nitrile rubber insulation. the outlet velocity not more than 7.5 m / sec. motor shall be ie3, class f insulation, ip55 rating, & suitable for 415 ± 10 % volts, 3 phase, 50 cycles ac supply. the noise level should be less than 65 dba at 1.5 m distance. unit to be tripped on receipt signal from fire damper installed in the room and interconnection with fire damper shall be provided. note: ahu should supply with inbuit control panel which is bms compititble. , 14 tr / 5600 cfm / 50 mm esp ( external static pressure ) ( vendor to verify the esp as per drawing for supply and calculate the total including internal pressure drops filter / coil / etc. ) ahu should have 1working +1 standby motor. , ahu connecting kit , refnet joints and other fittings , supply and installation of hard drawn 16g copper tubing insulated with 19 mm thick class o nitrile rubber insulation with gc cloth insulation shall be provided with weather proof additional cover for exposed areas. for indoor units tubing of appropriate diameter to be provided. all piping inside the room shall be properly supported with hanger and all external piping shall run in covered cable tray. piping quantity is mentioned is for pair of suction and discharge pipes. , gas charging and testing & commissioning of the system , supply & installation of transmission & control wiring with gi conduit between indoor and out door unit. , ( 2 core x 1.5 sq mm cu.cable ) , 4 core x 4 sqmm cu cable , supply & installation of support arrangement for out door units, ahu with necessary vibration isolation arrangement, ms frame for mounting the units to be provided with rubber pads, the frame should be painted with two coats black colour synthetic enamel paint. , supply & installation of gi class c drain pipe with 13 mm thk nitrile rubber insulation , 32 mm dia , 25 mm dia , supply & installation of perforated type powder coated m.s. cable trays of 50 mm in height & 2.5mmthick with two coats of red oxide and with necessarysupporting frame etc , 200 mm wide , 300 mm wide , supply & installation of bms integration charges for the vrv outdoor unit / indoor units from central controller to bms. all the outdoor / indoor unit parameters will be integrated through bms & required hardware / software to be included via modbus / bacnet. , supply , installation , testing & commissioning of split type airconditioners with scroll compressor comprising indoor air , outdoor condensing unit, with stand and all other necessary hardware for proper hanging of units. , hiwall split 2.0tr ac ( 3 star rating ) , hiwall split 1.5tr ac ( 3 star rating ) , all refrigerant piping shall be of copper, complete with supports between indoor & outdoor units duly insulated with 13mm nitrile rubber insulationwith gc cloth.rmt indicated is for set of piping between indoor and outdoor machine, individual piping will not be measured. , 1 / 4, 5 / 8 or equivalent to the unit , 1 / 4, 1 / 2 or equivalent to the unit , air distribution system , design, supply, fabrication and installation of g.s.s. ductingon every branch if there is, with required hardware’s, supports, wooden frame and painting on ducts, ms parts etc as per the smacna standard, approved drawings and instructions of engineer in charge with the following gauges. the ducts shall be fabricated from galvanized steel sheets class viii light coating of zinc conforming to iss: 277 1962 ( revised ) with accompanying mill test certificates.galvanizing shall be of 120gms / sq.m. ( total coating on both sides ) .exposed duct should provide with 26g aluminium cladding. , 24 g ( 0 750 ) , 22 g ( 751 1500 ) , 20 g ( 1501 2250 ) , 18 g ( 2250 above & plenums ) , supply, installation, testing and commissioning of gi volume control duct damper with bronze bush bearing complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. , 18g gi constructed vcd , supply, installation, testing & commissioning of back draft damper , 18g gi constructed bdd , supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , supply, installation, testing and balancing of powder coated extruded aluminium return air diffusers with removable core in accordance with the as directed and as instructed by oic es , supply, installation of extruded al. powder coated louvers for fresh air intake & exhaust complete withss bird screen mesh. , supply, installation, testing and balancing of extruded al. powder coated supply / return / exhaust air grilles with bronze bush bearing sleeve of different sizes , without collar damper , 150 x 150 with collar damper for toilet exhaust , supply installation testing and commissioning of motorised fire & smoke damper , casing made of 16g gi with factory fitted gi sleeve of 18g, 120 min fire rating complete with standard accessories as per ul 555s. , total area fire damper with pvc gear ( only damper price ) , smoke / fire sensors with all controls, accessories, actuators, extended sleeve for wall mounted ( actuator outside wall ) and other accessories torque 5 nm , supply, fabrication, installation and testing of the flexible connections constructed out of fire resistant double canvas sleeve as per instructed and as directed by oic es , supply, installation, testing and balancing of extruded al. profile powder coated supply & return slot diffuser of diiferent sizes. , 4 slot of 25 mm slot opening , hit & miss damper , inline fan , supply, installation, testing & commissioning of cabinet type / in line fan complete with forward curved / didw centrifugal fans, motor and drive. it shall be suitable for 230 ± 10% v, 1 phase, 50hz ac supply.. other accessories like inspection door, vibration isolator outlet mouth damper to be provided. , cap:500 cfm / 12 mm wc , insulation , supply and installation of external thermal insulation class o closed cell elastomeric nitrile rubber insulation with adhesives on ducts, tapes as per instuction and as directed by oic es , 13 mm thick for supply air duct in return air path , 19 mm thick for supply air duct , supply, installation and testing of acoustic lining for supply and return air ducts of following thickness of rigid fiber glass of 50kg / cum density covered with factory laminated rp tissue and finished with 26g perforated aluminium sheet as per the specifications. , 25 mm , 1 year warranty is included in the above items. cmc rate ( hvac components ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to six years without any escalation clause , part – b: hpc, cdc and other related work , research cluster head node 1 ( 1+1 redundency ) : dual intel xeon gold 5320 26 core, 2.2 ghz; 128 gb ecc ddr4 ram; shared storage – raid 5 / 6 usable 10 tib read intensive ssds or sas 10k rpm hdd with hot spare, ha configuration , research cluster login 1 ( 1+1 redundency ) : dual intel xeon gold 5320 26core, 2.2 ghz; 512 gb ecc ddr4 ram; shared storage – raid 5 / 6 usable 1.9 tib read intensive ssds or sas 10k rpm hdd with hot spare, load sharing with dns server , research cluster general nodes 1: dual intel xeon gold 6348 28 core, 2.6 ghz; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds , research cluster high memory nodes 1: dual epyc 7763 64 core, 2.45 ghz; 2048 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 1.9tb mixed use ssds , research cluster gpu nodes 1: dual intel xeon gold 6348 28 core, 2.6 ghz; ( or equivalent / better amd cpu ) ; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds; 2 x tesla a100 ( 80 gb ) nvlink / bridge , research cluster gpu nodes 2: dual intel xeon gold 6348 28 core, 2.6 ghz; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds; 2 x rtx a6000 / a40 nvlink or pcie , research cluster interconnect / network 1: a ) gigabit switch with all the compatible cables for managing all the cluster components with sufficient ports. managed switches with rps and redundant fans need to be offered in the solution. b ) gigabit switch with 10g sfp+ uplink ports , all the structured cabling and other required components for connecting all the client devices ( approximately 40 clients ) in the office area; 100g hdr infiniband off loading fat tree internally managed network on hdr 200 switches, secondary cluster management 1g network switches, remote management 1g network switch. managed switches with rps and redundant fans need to be offered in the solution. kvm switch with display, keyboard / mouse and adequate ports is required at each site for easy monitoring and troubleshooting of installed servers. , research cluster storage scratch 1 lustre: 1 pib usable on raid 6 ( 8+2 ) as per below : 200tib ( 50 gib / s write / read each individually ) must be offered using flash drives and 800 tib ( 10 gib / s write / read each individually ) must be offered using ssd / nl sas drives; scalable; all ssd / nl sas components should be high endurance enterprise grade; the metadata based file type wise policy for data backup / movement should be provided. 1 disk hot spare every 30 disks. the metadata / object storage array should be separate for both storage. metadata / object storage should be redundant and with ssds only of suitable capacity as per solution requirement with minimum 90000 files / sec. , research cluster linux licence ( rhel or equivalent ) for proposed cluster , research cluster pcm professional cluster manager solution for proposed cluster perpetual licence with oem’s support for 5yrs , research cluster compiler : latest version of intel one api hpc toolkit ( 2 concurrent users ) with 5 yrs support from oem professional workload / scheduler solution perpetual licence with support , research cluster pbs pro schedular professional workload / scheduler solution for proposed cluster + 2 nodes perpetual licence with support for 5 yrs , research cluster linux mn ( rhel or equivalent ) for proposed cluster , virtual servers ( 1+1 redundancy ) : dual intel xeon gold 6326 16 core, 2.9 ghz; 512 gb ecc ddr4 ram in 100% balanced memory configuration ; latest windows data centre edition virtual environment with windows hyperv service; expandable shared 50 tb usable raid 5 / 6 ( 8+2 ) san storage ( 1 disk hot spare every 30 disks ) ; scalable with all the cables and interface cards to establish the connectivity with redundant host server. , display:at least 42 1080p / 4k led wall mount smart tv with hdmi & usb, 20 watts sound, x protection pro outside the data centre for monitoring & management. , wifi and lan : dedicated 1gige lan connectivity to each office seating space ( ~ 60 ports / users ) and other room. managed wifi connectivity for entire area ( ~ 100 concurrent users ) is to be installed in compliance with actrec it infrastructure. briefly, two dgs 1010p e switches and five ac1750 aps could be installed for this requirement. , software solution for comprehensive building, cluster, interconnect, network & data centre resource management , man power & support ( 1 system administrator for day to day administration of i.t. infra, container / tool installation / maintenance, web / ftp servers, back up scheduling etc. + 1 data centre management engineer ) , all in 3 shifts for 24 x 7 x 365 days support covered by oem / vendor for 5 years. actrec will advertise and select support staff on behalf of the vendor for hpc and cdc management and administration. experienced employees of the vendors could also be qualified for the interview based upon the experience. , computational data centre ( cdc ) turn key: any other work required for complete and all inclusive functioning of project considering turn key project should be described by the vendor. additional items included here should be justified and detailed at the time of submission. , amenities: projector, interactive display, wall art, plants, recreation room accessories etc as per the details in tender document , 5 years warranty is included in the above items. cmc rate ( hpc, cdc and other related work ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to two years without any escalation clause , total equipment and works cost :part – a: core infrastructure ( civil+electrical+hvac ) +part – b: hpc, cdc and other related work including cmc as applicable...

MGM Medical College - Maharashtra

34172713 tender for reputed manufacturers and manufacturer appointed distributors for portable x ray machine, examination table, cubicle curtain track system, pvc comer & crash guards, false ceiling work, access control system, central heating system diesel generator 1500kva liquid medical oxygen, electrical outdoor panel, electrical distribution panel, medicines(injection, tablet, capsule, drop, syrum, powder, respirator product cream/ointment/lotion/oil) other products, vaccines & sera, orthopedic implants and cvts/cath lab disposables....

Bhabha Atomic Research Centre - Maharashtra

34067933 additional, alteration and maintenance of street lighting system, watch towers and outdoor feeder pillars in barc, trombay, mumbai 85 maintenance of junction box of street lighting poles routine servicing and maintenance of street light pole up to cable termination box ( j pole / straight / garden pole / tilted gi+grp straigh pole / wall mounted pole / flood light ) for led lighting fixture ) as per tss no. 1.0 2 street light pole without solar panels ( j pole / straight / tilted straight pole / wall mounted pole / garden pole / flood light ) 3 street light j poles with solar panels 4 maintenance of street lighting control db, feeder pillar & earth station routine servicing and maintenance of various, 415v, 3 phase, control distribution panel & feeder pillar as per tss no. 2.0 5 street lighting control db 6 & 4 way 6 out door feeder pillar 7 earth station 8 maintenance of lighting & power system at security watch towers routine servicing and maintenance of security watch towers ( spn db, power point, tubelights, ceiling fan, lighting fixtures, 63 amp junction box ) as per tss no. 3.0 9 sitc of following sizes of 1.1kv grade al.pvca / xlpepower cables as per tss no.4.0 10 supply of 4 c x 10 sq.mm. al conductor cable. 11 supply of 4 c x 16 sq.mm. al conductor cable. 12 installation 4 c x 10 / 16 sq.mm. cable under ground. 13 installation 4 c x 10 / 16 sq.mm. cable in hume pipe / gi pipe / openair ( as per tss no. 4.4 ) 14 only installation, testing and commissioning of following sizes of 1.1kv grade al.pvca / xlpe cables as per tss no.5.0 15 3.5 c x 70 / 95 / 185sq.mm. cable under ground 16 4 c x 2.5 sq.mm cu cable under ground / intrench 17 painting and stensiling ofstreet lighting poles including foundation of following types of poles as per tss no. 6.0 18 j type poles : 7.0 mtr. 19 garden light poles : 3.0 mtr. 20 straight light poles : 5.0 mtr. 21 straight poles : 6 mtr. ( flood light ) 22 wall mounted pole ( trombay hill ) 23 painting ofstreet lighting dbs & outdoor feeder pillar of following types as per tss no. 7.0 . 24 street lighting control db 6 & 4 way and sub db 25 outdoor feeder pilar 26 repair of street lighting pole foundation / coping of following types as per tss no. 8.0. 27 j type poles / garden pole / straight pole 28 excavation in following type of soil as per tss no. 9.0 of specification. 29 soft soil 30 murrum 31 hard rock. 32 supply & installation of end termination of following sizes of al. pvca cables as per tss no. 10.0 33 4core x 10 / 16 / 25 sq.mm. 34 3.5core x 70 / 95 sq.mm. 35 3.5core x 185 sq.mm. 36 supply, installtion, testing and commissioning of street lighting fixtures complete with all accessories, as per tss no. 11.0 37 led36w, street light 38 led72w, street light 39 led 50w, garden light, post top 40 led flood light 120w 41 20 / 21 w led lighting fixture outdoor type 42 supply, installtion, termination and connection of following sizes of flexible cables as per tss no. 12.0 43 4cx1.5 sq.mm. 44 4cx2.5 sq.mm. 45 supply and installtion of frp pole junction boxes as per tss no. 13.0 46 street light j pole j.b. 47 garden light j.b. 48 removal of existing damaged poles from breaking of concrete and transportationas per tss no. 14.0 49 street light j / straight pole. ( up to7.0 mtr. hight ) 50 garden light pole. ( approx.4 m ht. x 65 mm dia ) 51 old street light light db 52 supply and installation of following sizes ofg i pipes for installation of street light poles / cable as per tss no. 15.0 53 50 mm size 54 supply and installation of concret mix ( pcc ) at the site as per tss no. 16.0 55 supply, fabrication and installation of m.s. items as per tss no. 17.0 56 supply and installation of street light control distribution board as per tss no. 18.0 57 supply and installation, testing and commissioning ofstraight through joints of following sizes of stranded al. conductor 1.1 kv grade pvcacables as per tss no.19.0 58 4core x 10 / 16 / 25 sq.mm. 59 3.5 / 4 core x 70 / 95sqmm 60 3.5 / 4 core x 185sqmm 61 only installtion, testing and commissioning of street lighting fixtureson j pole / straight pole / wall mounted / garden pole / flood lightlighting fixture on complete with all accessories.as per tss no. 20.0. 62 fault finding due to trippingof power supplyper tss no. 21.0 63 providing temporary power supply as per tss no. 22.0 64 cable fault tracing different size of cable 4c / 3 & ½ c x25 to 185 sqmmas per tss no. 23.0 65 supply and installation of low density polyethelene film as per tss no. 24.0 66 supply and installation of following consumable items required for street lighting & security watch tower maintenance work as per tss no. 25.0 67 6amps. sp mcb 68 16 / 20 amps. sp mcb 69 time switch ( astro type ) 70 63 amp 4 pole contactor 71 solar panelcharge controler 72 150 ah battery for solar panelpoles 73 deployment and operation offour wheeler ( 5 seater ) with driveras per tss no. 26 74 deployment of above said vehicle 75 operation of above said vehicle...

Department Of Fertilizers - Maharashtra

34041848 bids are invited for power distribution panel for pond mcc etp, 440v, 3 phase, 4 wire, 1000a, 50hz, 2 incomers & 1 buscoup(q3) total quantity : 1...

University Of Pune - Maharashtra

33573501 repairs and maintenance contract for preventive and routine maintenance of ht and lt lines , substations, transformers, distribution panels and feeder pillers etc. at savitribai phule pune university preventive and routine maintenance of ht and lt lines, substation, transformers...

Indian Navy - Maharashtra

33420626 21bsic001 spares of rotating exciting converter, static converter, switch board and distribution panel , spares : , contactor auxilliary , front plate f pacco switch , switching element , toraion spring , fuse link low voltage , bearing , deviding wall , lamp pilot , adaptor screw ( type insert ) , fuse link low voltage , fuse base power low voltage size2 / 3 , ampermeter d1149 , handle ( toggle ) , main contact complete , fuse link low voltage size 2 , torsion spring , switch yaxely type , front plate , contact spring , torsion spring...

Balmer Lawrie And Co Limited - Maharashtra

33114124 design, manufacture, supply, installation and commissioning of outdoor reefer power supply distribution panel (18 reefer plug points) at our container freight station dronagiri...

New India Assurance Company Ltd - Maharashtra

33002306 tender for 1) providing, installing and commissioning of 18kw 3 phase electric meter for both flat (2w and 6e) at sundatta chs 2) providing and installing 10 sqmm 4 core copper cable from meter room to both the flats including material and labour charges 3) providing and fitting the new distribution panel with elcb, mccb, mcb and distribution of load including material and labour charges...

Central Public Works Department - Maharashtra

32692573 supply installation testing commissioning of main elect. distribution panel for getting separate best meter ( decentralisation of govt. offices ) at 2nd and ground floor of pratishtha bhawan, mumbai 20...

Public Works Department - Maharashtra

32416424 e.no. 4030 of 2022 23 prov. distribution panel and supply cale from 200 kva dtc near by vrushabhdev statue at bhilwad mangi hill at mangi tungi, tal. baglan, dist. nashik....

Tata Memorial Centre - Maharashtra

32233733 engineering, procurement, supply, installation, testing and commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , cat ( a ) turnkey works required forengineering, procurement, supply, installation, testing & commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , civil work , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 80mm with riser panel arrangement ( including prefilter, damper & riser grill all clean room compliant ) wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 50mm with riser panel arrangement wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin totally flush walkable false ceiling made of 0.8mm thick powder coated sheets on both sides withpuf of density 40 ± 2 kg / m³ as infill, gi profiles for reinforcement along the periphery, including ceiling gridfor easy installation and necessary hardware. joints shall be sealed with cleanroom compatible silicon sealant. ( load bearing capacity 150 kg / m2 ) the thickness of panel shall 50mm as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. factory made cut out to be made in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. curvature radius : r 70 type. joint to be sealed with cleanroom compatible sealant. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor.3d internal / external corner coves. joint to be sealed with cleanroom compatible sealant. , providing and fixing flush doors 35mm thick with 1.0 mm laminates on both sides. the item includes teakwood chaukhat ( frame ) made from 75x50 teakwood. the door to have 12mm teak wood lipping on edges. the door is to be complete with cylindrical door lock , 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. coving in epoxy screed for wall to floor. joint to be sealed with cleanroom compatible sealant. , supply and installation of 46 mm thick doors made with pu painted 0.8mm thick gpsp sheets on both sides with puf as infill, 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures. alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , supply and installation of 46 mm thick emergency doors made with fire retardant paint having fire protective certification for 120mintues for door along with suitable infill to resist temperature upto 600 700 degree , alongwith 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures.alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , demolishing existing brick masonry and tiles with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry / rcc structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises and scope also include dismantling and careful removal of doors, distribution panel and storing and stacking complete all as directed by the engineer in charge. ( existing toilets, guard room & record room & ground floor & all areas wherever required for converting ward to cgmp facility ) . the scope also includes cleaning of flooring and scraping, levelling for application of self levelling epoxy coat for flooring. , dismantling of wash basin and removing of wall tiles and all the allied stonework and pipes & fittings wherever necessary and disposal of unserviceable material carting away the debris out of hospital premises or handing over the same to engineer in charge , providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle size 600mm center to center, lock and stopper etc. included in the item rate ) .as approved by engineer incharge. , providing and fixing panic bar / latch ( double point ) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the engineer in charge, all complete. , providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminium sheet having electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing and applying 3mm to 4 mm thick self levelling epoxy flooring system which consist of surface preparation, by grinding the surface , minor repairs if any, applying 1coat of epoxy primer , laying self levelling epoxy screed followed by top coat of self levelling epoxy coat as per manufacturer specification , work inclusive of existing flooring reparing and wall crack filling complete job as directed by eic. , applying 1 2mm thick birla white wall putty followed by final coat of epoxy wall painting wherever required as per the instruction of engineer incharge. , providing and applying and levelling the existing surface with birla white cement based / coloured waterproof putti of average thickness of 2 mm of approved thickness, brand and manufacture, over the plastered wall surface to prepare the surface even and smooth ready for painting purpose etc complete ( rate inclusive of scaffolding matetrial, labour charges ) etc. , providing and applyingacrylic ( premium ) emulsion paint of approvedmakeandshadeonwallswithsand papering& cleaning the surface, applying one coat of primer and lambi / puttytofullsurface3times, thereafterpaintingthe surfaceintwo coatsoverbaseprimercoattoachieveeven finish. rate is inclusive of all double scaffolding, all material and cleaning as per manufactures standard application method & specification etc. complete. , extra cost for projected return air riser panel made of 0.8mm thick powder coated sheets with 150mm projection above the ceiling and flange for fixing duct, with provision for fixing ra grill and filter etc. , gipc perforated grill for return air riser grill of 1.2mm thick with capsulation perforations for return with all necessary fixing arrangements. , supply and installation of 10 micron pre filter for return air riser ( 1000 x 500 mm ) as per the instruction of engineer in charge. , factory made cutout in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , providing and fixing of pvc conduit 32 mm in the wall panels , factory made cut outs with concealed in wall panel for electrical sockets, switch boards, mgs, etc. , providing & laying poly vinyl chloride ( pvc ) rolls flooringmanufactured of approved make and approved pattern for flooring, skirting / dadolaid on existing cement tile or concrete of plastered floor finish with suitable adhesive as per manufacturers specifications closejointed and finished to proper bends, slopes and plumbs asdirected etc. complete generally as per manufacturer’s specifications. providing & laying new2mm thck pvc flooring tiles. , toughened lacquered glass panelling: providing and fixing of 6mm thick toughened glass ( premium griha rated lacquered glass from glass manufacturer ) of approved colour by doit&c, mounted on clip ( j / j1 / i type ) or equivalent on a perfectly levelled surface ( granite cladded pedestal ) . lacquered strong glass must be made industrially ( via curtain coating process ) ; opaque ( if viewed against a support wall ) , coated with pu lacquer ( 100 micron thick ) ; colour consistency ( measured by spectrophotometer cm5081 ) ; highly durable ( passes persoz hardness test for minimum 220 oscillations ) ; humid resistant ( conforms to bs en 1036 1999 ) ; environmentally friendly ( no lead, no arsenic, no copper, no formaldehyde ) ; appropriate recycled content ( 12% post industrial / 6% post consumer ) ; compressive strength ( 1000 mpa ) & tensile strength ( 40 mpa ) , same as float glass. tempering should be done as the en 12150. glasses are to be fixed with polymer clips ( single sided j1 & j2 type, double sided i type ) , white backing foam and grey impact absorbing foam; to accommodate upto ± 10mm substrate undulation, and with a horizontal load capacity of 30kg / 100mm and vertical pullout load > 200kg / 100mm, glass should be supported with 1mm thick lip covering upto 3mm of glass surface; clips should be fixed using durable, non corrosive, strong s.s.screw 45mm long. all wooden material to be used shall be anti termite treated. the measurement only for the portion covered by glass to be considered. , granite cladded pedestal made from 200mm thick aac single block masonary including providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut on the blockwork with 1:4 cement mortar on all sides. including resting provision for glass panelling / partition. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge. , dismantling, breaking and cutting of slab by mechanical means i.e by using diamond cutter / sawing machine without causing damage to any beams and columns and lowering the cut pieces of concrete using chain pulley block on the respective lower floor level and handling the cut pieces including cutting it in smaller pieces and stacking / dispose the debris inside the campus as per the instruction of engineer incharge. item includes floor breaking and dismantling. , cutting of tiles and removing mortar for placement of electrical conduits in the floor and then covering the cement grouting flushed at floor level. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge excluding cost of electrical conduits. , structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and painting, including welding, bolting fixing with labour and material all complete. , providing metal roofing sheets manufactured from zinc / aluminum alloy colour coated fromn high tensile steel minimum yield strength 550 mpa; total coated thickness0.60 mm. profile and colour as approved by the architect ; generally as per durashine brand marketed by tata bluescope steel or equivalent including fixing as per manufacturers recommendations and includingflashings and accessories such as ridges, corner flashings, end flashings and galvanised fasteners from reputedmanufacturers such as mark fasteners. for correct levelling and alignment of sheets height of purlin tops shall be adjusted as provided in purlin connections. mode of measurements: plain area in the inclined plane of sheets shall be measured. nothing extra shall be added for collugations, profile, side laps, end laps etc. , supply and installation of double glazed view panels embedded in the clean room wall partitions with flush design fixed with 6mm thick toughened glass and necessary accessories. , window modification as per the instruction of engineer incharge. , dismantling of existing fire fighting system as per the instructoin of engineer incharge , providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building / structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia m.s. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with m.s. tubes, m.s. tube challis, m.s. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. the scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of engineer in charge. note: ( 1 ) the elevational area of the scaffolding shall be measured for payment purpose. ( 2 ) the payment will be made once only for execution of all items for such works. , providing and laying in position ready mixed m15 grade plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of r.m.c. from transit mixer to site of laying and curing, including the cost of centering, scaffolding, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the engineerin charge. ( m15 grade at all locations upto plinth level ) , providing and laying in position ready mixed m 25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of r.m.c. from transit mixer to site of laying, including the cost of centering, scaffolding, shuttering, finishing, including cost of admixturesin recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability and including supply and installation ofpvc water stopper as per direction of the engineer in charge at all levels. , providing and fixing of reinforcement steel including material fabricating, trasporting, loading, unloading, storing on raised steel rack platform, handling, straightening, cutting to length, bending, making hooked ends, hoisting into place at all levels and heights and binding in position ( including providing & using 18 gauge binding wire ) reinforcement bars of all diameters ( is 1786 , fe 500 of all grade ) to shape and size as per approved bar bending schedules and structural drgs. for all kinds of works at all heights & depths as specified including cost of approved quality pvc / concrete cover blocks, spacers, chairs at regular interval as per relevant is code and such other works that are required to make it complete.quantity of steel as per drawing, approved bbs and with authorized overlaps only shall be measured and paid for. quantity for chairs and spacer bars will not be paid. the measurement shall be as per is 1200 and reinforcement hooks and bends shall comply with the requirement of is 2502 unless clearly specified above. , aluminum partition workproviding & fixing alumimium partitionto the requiredheight partly glazed and partly panneledusing anodized aluminium section with satin finish anodizing of required size for bottom, top, middle &vertical rails at required intervals panneling with 12mm thickboth side pre laminatd board fixed with sloping aluminium beeding alround with neoprine gasket glazing with 5.5mm plain glass of approved make fixed withalumimium channel beeding two way pvc lining / rubber gasket to ensure water tightness and including providing necessary cover mould using suitable alumimium section so as to take care of gaps between the walls / ceiling / flooring and partitions etc. including providing and fixing necessary fittings as specified and directed. , aluminum sliding door providing and fixing sliding door to consist of partly glazed and partly panneled with using 5.5mm thick glass sheet of approved make and quality plain glass of approved make fixed with anodized aluminium sloping channel beeding with two way pvc lining / rubber gasket to ensure water tightness and panneling with 12mm thick nosva pan or ancholam board prelamimated board rated on both side as required, guiding rail section, vertical rails section includingproviding pvc guidrails of six 12mmx75mmas required at size concealed type locking arrangement and heavy duty handle set as per requirement including providing & fixing of18mm thick commercial ply with approved laminate of 1.5mm thick and teak wood lipping patti and non laminated surfaces should be polished with approved french polish at requiredshade & colour. , excavation mechanically ( using excavators like jcb / poclain / with bucket ) in all types of soil, including murrum, soft rockfor foundations, wall, columns, plinth beams, basement, raft, ducts, trenches, underground sumps, septic tanks, soak well including shoring and strutting, bailing out water / pumping off water if required, removing and stacking or disposing simultaneously the excavated soilanywhere within the actrec campus and / or spreading soils in layers for site development. all complete as per specification and as directed by the engineer incharge. for depth upto 1.5m. , removal and stacking of paver blocks taking out existing cc interlocking paver blocks from footpath / central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of engineer in charge. , dry stone rubble soling / pitching of 230 250mm size shall be approved quality, hard, free from cracks, durable, preferably black trap. rubble shall be laid on leveled base close to give compact, surface. if base is not properly leveledsame will have to be done without any extra cost. voids in the joints shall be filled with selected chips. a sample of paving shall be prepared and got approved before proceeding ahead. after stones are laid with thickness of 200mm and packed with chips, sandshall be spread and watered to fill remaining voids. sandshall be allowed to go into joints till final packing is obtained. rate quoted shall be for materials, labour, watering, leveling site, before paving, consolidating etc. complete. , providing & fixing soap dispenser metallic bottle. , p&f soap dish holder. , providing & fixing toilet paper holder with flap recessed type ( stainless steel ) . , p&f stainless steel surface mounted sanitary napkin disposal ( with flap ) of approved quality / make. cabinet 18 8, type 304, stainless steel size 270mm ( l ) x 105mm ( w ) x 385mm ( d ) capacity: 4.6 litres equipped with full length stainless steel piano flap , paper towel dispenser. cabinet 18 8, type 304, size 265x90x365 stainless steel finish: stainless steel satin capacity: 450 c fold, 600 multifold , p & f stainless steel hand dryer of approved quality / make. casing:stainless steel # 304 non magnetic, matt finish mounting :wall mounted operation :touch free infra red activation sensor range : 12 cm 15 cm hand dry time :less than 20 secs auto cutoff: 30 seconds motor:brush type, dual ball bearings speed:25, 000 rpm rated power :550 w ( no heating element ) current:2.5 a protection class :ip x 1 blowing volume : > 270 m3 / h air speed:95 m / s ( with speed controller ) , modular cubicle based restrooms of stainless steel make with stainless steel hardware with locking arrangement and 1 spare lock each.handles and hinges to be included in the rate. measurement per cubicle. , p & f 1st quality wvc urinal ( is:2556 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc. complete. cera cat no: s4010101 efs or equivalent , p & f 12mm thick toughened glass urinal partition with all type fitting. ( partition size 300mm x 1050 ) , providing & laying cast in situ rcc m25 grade of concrete. reinforced cement concrete: ( rcc ) reinforced cement concrete of m25 grade using graded stone aggregate of 20mm max. size including consolidation with vibrator & needle of required capacity finishing curing including form work, shuttering and steel reinforcement etc. complete all as directed by the engineer in charge. , a ) . columns ( rmc ) , a ) . lintel & tie beams ( rmc ) , b ) . sunshades ( rmc ) , reinforcement: reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the engineer in charge. ( laps will not be measured ) . with high yield strength deformed bars ( tmt bars ) & ms round bars , providing and fixing of steel shuttering wherever required as per the instruction of engineer incharge , brick work: brick work at all floor level with cement mortar 1:4 using well burnt locally available bricks of approved quality including scaffolding, raking out joints above ground level simultaneous and as directed by engineer in charge. in foundation & plinth drain walls chambers & superstructure of all floor levels , providing & laying of 20mm thk. external wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & laying of 20mm thk. internal wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & applying of 2 coats of apex weatherproof paint alongwith one coat of primer to the out side plastered surfaces. , providing & applying of oil bound distemper to theinside plastered surfaces , providing & laying of cc flooring ( 50mm thk ) as per the instruction of engineer incharge. , aluminum openable windows providing & fixing in position aluminium openable window shutter with frame fully glazed / aluminium grills withusing 5.5mm thick glass sheet of approved make and qualityplain / frusted / bajari glass of approved make fixed with aluminium beedingchannels with two way rubber gasket / pvc lining to ensurewater tightness and nos rattling for aluminium grill fixing with fchannel beeding using satin finish anosdized 15 micron jindalsectionsfor shutters and frameof required size and sectionincluding using aluminium / s.s. hinges of required size, tower bolt of required size, c type alum handle for shutterand othernecessary hardware as per requirement etc. complete all asper specified and directed by engineer in charge. the sections should be anodised. , labour charges for alum works : removing the existing partitions / doors and handing over the same at required place anywhere inside the actrec campus as indicated by the engineer in charge. etc. complete. , c.p.v.c. pipes:providing, laying, jointing, fitting, testing heavy quality c.p.v.c. pipes of required dia including all fittings including all brass fixtures such mt and ft required as per site requirement & laying the same at any floor levels including scaffolding all jointing materials & clamping in wooden blocks if required etc. complete as directed & specified by engineer in charge. , 15mm , 20mm , 25mm , 50mm , vetrified dado tiles providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete as per the instruction of engineer incharge. , vetrified floor tiles: providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete. , e.w.c.:providing and fixing white vitreous china pedestaltype water closet ( european type w.c. pan ) with seatand lid, level white p.v.c. flushing cistern with capacity as mentioned below, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittingsand fixtures complete including cutting and makinggood the walls and floors wherever required. it should include p or s trap as per approved make with left or right vent in position including fixing it on chair brakcet or wall bracket. with necessary c.p. brass screws & plugs etc.floor mounted ewc universal with 5 to 7 ltrs cistern:special colour as per instruction , pressmatic taps :urinal valve auto closing system with built in control cock with wall flange . providing and fixing including removal of existing if any as per the instruction of eic , granite: providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut for kitchen / toiletplatforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) with joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels of colour black / red / grey etc. , providing and laying water proofing treatment of average 100 mm thick for sunk slabs of toilets and wherever necessary at all the levels with brick / stone aggregates, with layer of 20 mm thickcement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with water proofing compound as specified by the manufacturer, layingbrick bats of required size impregnating in to the base mortar bed with gap of 12 mm all aroundaccording to slope, level and curing the same, the gaps around brick bats filled with cement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with waterproofing compound, 20 30 mm layer above brick bats and finishing top with neat cement @ 2.75 kg / sq.m. screeding and curing etc. in line, level and plumb / slope, complete including furnishing of guarantee for 10 years. ( note : the above rates shall be inclusive of providing and mixing of waterproofing compound as per manufacturers specifications ) , fancy pillar tap: providing & fixing approved make heavy quality c.p.brass screw down pillar tap long nose not less than 810gm. with jam nut easy clean variety of 15 mm n.b. etc. complete all as directed by the engineer in charge , nahani trap: providing & fixing 100mm dia c.i heavy duty nahani trapwith bras c.p. dome type heavy duty s.s. jali all as approved make quality as specified and directed by engineer in charge one way / two way need concrete joints.extra if required , water shower moc ss 304 with all necessary arrangements . , overall size ( 2450 x 2000 x 2000 ) mm. , pass box dynamic dynamic pass box , made out of ss 304 with no 4 finish. should have 600 mm ( h ) , 600mm ( w ) and 600 mm ( l ) internal sizes , supply of ss wall bench bench with ss sink and sensor tap of size 750l x750w x900mmh as per the layout drawing consists of moc: ss 304sheet finish: no4 mat under bench storage module having450x450x180 ss sink sensor one way tap shutters and accessories likesshinges, , ss d handlesetc., pedestal with adjustment set and 25 mm double skin puf infilled top , drain collection tank with weighing scale: , supply of emergency eye wash shower moc ss 304 , electrical work , dg set supply , installation, testing & commisioning of diesel generating ( d.g. ) set with class g3 governing ( 40% step load ) , alternator of 625 kva output at 0.8 pf continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 v, 50c / s, radiator cooled, multi cylinder diesel engine at 1500 rpm , seperately excited amg having class h, spdp alternator ( with battery charging generator ) , with static avr + / 1% & thd<3%, running at 1500 rpm. both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having engine & generator protection ( including ref & rpr ) / parameter display / operator interface / power command 3.3 control system / amf panel / synchronization / dedicated earthing system / rs 485 modbus connectivity, etc. the complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 db at 1 meter, made of 16 / 14 swg crca sheet, complete with first filling of lube oil / diesel / coolant & fuel hoses, battery, 990 liter external fuel tank, residential silencers, mounted on plinth & obtaining necessary approval from electrical inspector. a ) exhaust piping to be raised upto terace level of nearest building. b ) power / control cabling, terminations, etc. c ) 990 ltr. capacity external deisel tank.d ) . height of stack to be maintained as= height of building + 0.2 * vkva . e ) factory testing to be carried out in present of actrec engineering before despatch of equipments. , 625 kva dg set , amf panelsuitable for 625 kva diesel generating set with battery charger and standard accessories. , ms class ‘b’ diesel engine exhaust pipe of suitable size ( including all fittings, clamps, steel support ) of suitable dia for the engine. the pipe shall be provided with 12 mm thick ceramicfibre rope and below to be insulated with cloth and glass wool. , supply & installation of exhaust pipe thermal insulation and cladding. , installation of silencer , supply & installation of silencer thermal insulation and cladding , supply & installation of m.s. supports for exhaust pipe & exhaust structure suitable for 1 x 200 mm exhaust pipe ( structure height 25 mtrs ) including standar panel & tray , supply & installation of s.s. bellows 200 mm with matching flanges, gaskets and fasteners , ups 3 phase in 3 phase out with igbt pwm based rectifier technology with isolation transformer ac input voltage:415 v + / 10% , frequency:50 hz + / 5%, output voltage:415v + / 2% , output frequency:50hz + / 0.5%, efficiency: 0.9. type of battery:smf, battery capacity: for a backup time of as specified, battery charging current:shall be calculate for unity power factor. protection: electronic over voltage trip, electronic under voltage trip, single phase prevention, overload, short circuit and battery overcharge, indications: ac on, inverter on charger fuse, inverter trip. one number rs232 ports to steady the data with all accessories complete etc., , 160kva online ups with isolation transformer 3 phase i / p and 3 phase o / p with 30minutes backup. , sealed maintenance free batteryof 34nos, 12v / 130ah, 30minutes backup. , battery rack with accessories for 160kva ups. , lv panels free standing, floor mounted mcc panel made out of 2mm thick crca sheet duly powder coated after seven tank process consisting of suitable rating incomer, aluminum bus bar supported with dmc / smc barriers & color coded with heat shrinkable sleeves, metering and outgoing feeders ( as mentioned against each panel ) : , mcc panel 1 for ahu 1, 2, 3, 4, 5, 6, 7, 8 ahu for exhaust 2 nos, mcc 2, ups, ldb 1, pdb 1&2 ( as per enclosed sld ) . , mcc panel 02 for air cooled chiller 1, 2 &3 chilled water pump 1, 2, 3, 4, 5, hot water generator 1, hot water generator 2, hot water pump 1, hot water pump 2. ( as per enclosed sld ) , ups panel for eldb 1 , epdb 1 , epdb 2 & epdb 3. ( as per enclosed sld ) , lv ( power & control ) cables 1.1kv grade xlpe / pvc insulated aluminum / copper multi strand conductor steel armoured cables. , 3.5c x300mm² al. armd. xlpe insulated cable. , excavation and cable layoing and backfilling as per the iso norms , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable. , 3.5c x 25mm² al. armd. xlpe insulated cable. , 4 c x 4mm² cu. armd. xlpe insulated cable. , 4 c x 2.5mm² cu. armd. xlpe insulated cable. , 3 c x 6mm² cu. armd. xlpe insulated cable. , 3 c x 4mm² cu. armd. xlpe insulated cable. , 3 c x 2.5mm² cu. armd. xlpe insulated cable. , 1c x35mm² cu. unarmd. xlpe insulated cable. , 1c x70mm² cu. unarmd. xlpe insulated cable. , lv cable end terminations termination of cables with brass double compression glands including cost of crimping lugs / ferrules, solder, cable sockets, insulation tapes etc. , 3.5c x300mm² al. armd. xlpe insulated cable. , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable terminations. , 3.5c x 25mm² al. armd. xlpe insulated cable terminations. , 4 c x 4mm² cu. armd. xlpe insulated cable terminations. , 4 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 3 c x 6mm² cu. armd. xlpe insulated cable terminations. , 3 c x 4mm² cu. armd. xlpe insulated cable terminations. , 3 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 1c x35mm² cu. unarmd. xlpe insulated cable terminations. , 1c x70mm² cu. unarmd. xlpe insulated cable terminations. , earthing supply, installation testing of earthing station as per is standard complete with 600x600x6mm gi plate electrode, salt, charcoal, 2 nos. 50x6 mm aluminum strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm gi strip. , 25x3mm gi strip. , 6mm² single core multi strand wire ( green color ) . , 10mm² single core multi strand wire ( green color ) . , supply, installation testing of earthing station as per is standard complete with 600x600x3mm copper plate electrode, salt, charcoal, 2 nos. 50x6 mm copper strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm copper strip. , 25x3mm copper strip. , 2000mmx1000mmx12mm corriguated rubber mats, as per standards. , d.c.p. type fire extinguisher for following capacity cartridge type with gun metal cap 150gram co2 gas cartridge, powder and brackets confirming to is 2171 19885 andcompleted erected with necessary clamps made from 50 x 6mm. ms flat with nut & bolts grouted in wallcomplete. 6kg capacity. , carbon dioxide ( co2 ) fire extinguisher user of following capacity with necessary clamps made from 50 x 6mmm.s. flat with nut & bolts grouted in wall complete. 4.5 kg capacity. , mcb distribution boards : , 12way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 12 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 8way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 8 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 1 phase, 8 way lighting distribution board with horizontal double door type40a dp el mcbas a incomer, 6nos. 6 10a sp mcb as a outgoing circuit. mcb shall be provided with “c” curve , 3 phase , 12 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a dp mcb per phase& 30 nos. 16a / 20a sp mcbin outgoing circuit . ( 10 nos, mcb per phase ) ( pdb ) . mcb shall be provided with “c” curve , 3 phase , 8 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a, 300ma, dp elcb per phase& 18 nos. 16a / 20a sp mcbin outgoing circuit . ( 8 nos, mcb per phase ) ( pdb ) .mcb shall be provided with “c” curve , modular & industrial type switch sockets switch socket industrial type industrial pentra type socket & plug with mcb enclosed in enclosure. the scope includes fixing of enclosures , supply of all fixing accessories / hardware. mcb and socket shall be wired up upto outgoing terminals etc, complete as required. , single phase 25 amp 3 pin socket with straight connected plugwith 25 amp dp mcb. , single phase 32 amp 3 pin socket with straight connected plugwith 32 amp dp mcb. , three phase 32 amp 5 pin socket with straight connected plugwith 32 amp fp mcb. , modular type switch / sockets / lan / telephone system the crca modular box shall be concealed in such way that front plate flush withmodular partition wall and& brick wall front plate shall be ss 304 matt finish. , 16 amp switch 1 nos. with modular box, front & rear plate. , 16 amp switch 2 nos. with modular box front & rear plate. , 16 amp switch 3 nos. with modular box front& rear plate. , 6 / 16 amp switch socket 1 no. with modular box front & rear plate. , 6 / 16 amp switch socket 2 no. with modular box front & rear plate. , rj45 lan socket 1 nos. with modular box front & rear plate. , rj11 lan socket 1 nos. with modular box front & rear plate. , rj45 socketeach 1 nos. with modular box front & rear plate. , cat 6 flexible cable. , 50 pair telephone junction box , 12u rack with 4 nos. 24 port patch panel with all accessaries. , wi fi network point with all accessaries. , 50 pair telephone cable , ip telephone instrument , analogue telephone instrument , supplying and fixing 1 meter length, utp patch cord of cat 6 type in position as per requirement. , supplying and fixing 7 ft length, utp patch cord of cat 6 type in position as per requirement for end point device ( pc / laptop etc ) , sitc of lazr speed 300 fiber, 6 core indoor application, multimode, to be laid through conduit and flexible with all the connectors, couplers, pigtels, lius at both endcrca module box , the crca module box shall be concealed / surface mounted on brick wall / modular partion. , light fixtures , 42w led bottom openable type cleanroom light fixtutre. , 20w led bottom openable type cleanroom light fixtutre. , 39 / 40w led batten type light fixtures. , 1.1 kv, grade frls, pvc insulated multi strand copper flexible cables , 3c x 1.5mm² cu. flexible cable. , 3c x 2.5mm² cu. flexible cable. , 3c x 4mm² cu. flexible cable. , 3c x 6mm² cu. flexible cable. , 5c x 6mm² cu. flexible cable. , 3c x 10mm² cu. flexible cable. , flexible cable terminations including crimping lugs / ferrules etc. complete as required , 3c x 1.5mm² cu. flexible cable terminations. , 3c x 2.5mm² cu. flexible cable terminations. , 3c x 4mm² cu. flexible cable terminations. , 5c x 6mm² cu. flexible cable terminations. , 3c x 10mm² cu. flexible cable terminations. , supply and installation of gi perforated & ladder cable trays : hot dipped galvanized and minimum thickness of hot dip coating is 70 to 100 microns. thickness of cable tray sheet steel for 50 mm to 300 mm cable tray 2.0mm thickminimum height of the perforated cable tray is 30mm or 50mm. cable tray shall be in different widths and shall be in standard length 2500mm long and suitable to couple two cable trays with coupler. support required for fixing the cable trays considered in the structural steel , 50mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 100mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 150mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 300mm ( w ) x 50 mm ( h x 2mm thinkness perforated cable tray. , 450mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 600mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , structural steel for supports. , pvc conduit with bends, junction boxes, and all necessary accessories and hard ware as following. , 25 mm pvc conduit. , pvc flexible conduit with clamps and all necessary accessories and hard ware as following. , 25 mm flexible conduit. , ceiling fan , 1200mm sweep ceiling fan , bms system software , bms software: graphical user interface software based on ms windows with1000 points & 1 client license .the system should be accessible from anywhere on lanor ethernet . the communication protocol shall be bacnet protocols . system should be scalable in all levels , eggineer and user level passwords. , bms client station:intel i7 3rd generation processor 3ghz, with 1tb x 2nos hard disk, 16 gb ram / dvd rw / keyboard / optical mouse / lan card / 32” led monitor. minimum 4 usb ports. with pre loaded licensed windows 10 professional software ( latest version ) , ms office and anti virus, dual 2gb graphic cards as per tender specification. , server pc: the main servers will be intel xeon processor e5 2600, minimum speed of 2.3 ghz with 6 core, dual gigabit ethernet port, usb port, video port. the server memory will be 16 gb ddr4 ram with 21 inch monitor , laser printer for alarms and reports a4 size ( black & white ) , ddc panels ip based ddc controllers with in built real time clock, 32 bit micro processor cpu, memory, enclosed in ms powder coated enclosureas per io summary , ddc 1&2 ( ahu 1, aeu 1 & ahu 6, aeu 6 ) with io points ofai 26, di 24, ao 10 & do 08 , ddc 3&4 ( ahu 2, 3 & ahu 4, 5 ) with io points of ai 22, di 14, ao 08 & do 04 , ddc 5 for emswith io points of ai 62 , di 0, ao 18 & do 0 , gatewaymodule for integrating the third party systems communicating on one of the standard open protocols such as bacnetand modbus, etc with bms , chiller intigration, energy meters, hot water generator , field instruments testing and commissioning of following instruments with required accessories , dp switch across fan to monitor filter clog status monitoring ( fine filter ) range: max 1000 pa , differential pressure switch for ahu run status range: max 500 pa , duct dp transmitter across fan , room temp, rh & dp display unit with inbuilt dp and external temp & rh transmitter , static pressure senosr for vfd speed , duct mount temperature & rh sensor with temp accuracy: ±2% & rh accuracy: ±3% , damper actuators , room temperature & rh , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 4c x 1 sq mm armoured copper shielded cable , 2c x 1 sq mm armoured copper shielded cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 8 port network switch with rack , validation & documentation : thevalidation to be done after the validation & commisisoning of the facility , validation and commissioning of entire facility including the qualification and operational approach ( protocols for sat and iq and oq, or ioq ) .validation of the bms system with related qualification documents dq / iq / oq / pq as per international norms and client standards. , fire alarm system , addressable2 loop fire alarm control panel ( facp ) with battery charger and with the battery back up for 8 hours normal operation and one hour alarm operation.the facp shall be expandable upto 10 loop. the facp shall include a full featured operator interface control and annunciation panel that shall include a backlit 640 character liquid crystal display, and a qwerty style alphanumeric keypad for the field programming and control of the fire alarm system.system should support upto 159 detectors and 159 modules in one loop. the panel shall be ul listedand fm approved and comply ul 864, 9th edition requirement. the enclosure shall also be ul listed. the quoted rate shall include supply of necessary software and harware for progamming the panel with all necessary licence. ( with fiber support ) , intelligent analog addressable photothermal detector complete with mounting base complete as required. , intelligent analog addressable hest detector complete with mounting base complete as required. , manualcall point with address switch to programme the modules which monitors and reports contact status..complete as required as per technical specification. , addressable horn cum strobe complete as required. , analogue addressable control relay module for ahu tripping and shall bewith the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , should be capable of monitoring shorted loop circuit and automatically restore communications when shorted condi , analogue addressable control module shall be with the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , active repeater panel with minimum 640 character backlight lcd display with qwerty keypad and fixed function keys and soft keys. it should have control and display capabilities for all nodes of the network. should have the facility to store 1000 alarm event & 4000 system events. the panel shall be ul listed and fm approved.complete as required as per technical specification. ( with fiber support ) , response indicator , 2c x1.5 mm², pvc insulated frls armoured copper cable for slc loop & power supply, confirming to is standards and specifications..complete as required as per technical specification. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , exit signages , 10a power supply unit , access control system , door access control system access control desktop pc with thefollowingminimumspecifications:intelcorei5, 3ghz, 4gbram, 500gb hdd, 32lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmi output, configurationwithwindows10 pro, office 12 and antivirus , access control system software , time attendance software system as per clients requirement. , access control system will be magnetic door type controlled through card readers and biometrically inncluding all accessories and with necessary cables and terminations. the system will be capable to record the biometric attendance of the authorized personnel and the records will be stored in server. magnetic lock and door sensor , emergency release switch in green polycabonate housing / push to break glass type , proximity cards complete as required , cat 6 cable , ethernet switch 16 channel , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , arrangement of interconnection between fire alarm system and access control system to automatically open the door in case fire emergency. , door interlock system , 2 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable end terminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , 3 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable endterminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , cctv system , professional grade network video management recorder, comprising 32ch. nvr to record output of all cameras mentioned above with 1920x1080p resolution @30fps, third party ip camera supported, h.264 compression up to5megapixelsresolutionrecording, multipleharddisksloteachhavingmaximumstoragecapacityof24tb, minimum of 30 days recording motion / continuous, 720p @ 25 fps recorded view, and 1920x1080p @30fps live view, 2 usb 2.0 or 3.0, httpnetworkable, backupbyusb / dvdwr, redundant backup of nvr scheme, included software, client licenses and required camera licenses complete as per technical specifications and as required. all the components to be of same make as camera. nvr shall be bis certified. , ip65dome network camera full hd 2 mega pixel low illumination lux 0.5 high sensitivity with 1 / 2 inch progressive image sensor, h.265+ video compression, 1920x1080 @ 20 fps with poe powersupported, onvif s profile, face detection etc, operating temp 10 to +40 degree c, certification bis approved. ( indoor application ) , networktdnirindooroutdoorbulletcamera1by3cmos1, 3mp3point6mmfixed24irledspoe h264, excellent low light performance with 3d noise reduction, saving storage and bandwidth together with h.264 high profile codec , 24portmanagedswitchwith poe / poe+, as required, i / c connections ofl3 switchwith 16port switchx 10 / 100 / 1000t poe ports and 4 x100 / 1000x sfp ports complete etc. as required , rj 45 connectors , closed wall mount rack 12u , led display monitor: the sufficient no. of full hd led monitors with high resolutions screen size of 52” ( diagonal ) are to be provided for viewing all live / recordedcameraproceedings.theresolutionsof1920 ( h ) x1080 ( v ) pixelswithcomfortableviewingangleis proposedforallmonitorssuitableforoperationon220 240vac50hzpowerforthedisplaypanelshouldbe equipped with all standard features such as video in, audio in, hdmi / dvi, rj 45 port etc. , cat 6 utp cable with accessories. , sitc of 3 core*1.5sqmm frls unarmoured power cable with all accessories complete as required. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , p.a. system , six zone voice controller with necessary interface to fire alarm system, and zonal configuration facility complete along with up to 255 pre recorded message, emg evacuation message , high quality 6 watt, 100vspeakers with box ringin ceilingmounted type with tansformer & terminations. , 6w volume control regulator , 250w amplifier , mixing amplifier , table top microphone. , equipment rack for pasystem unit with secure lock & key. , cd player for music source , 0.75sqmm twin twsted wires for speaker on cable tray or pre fixed conduits including terminations. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , e.m.s. system , standalone controller operator pc: pc with thefollowingminimumspecifications:intelcorei7, 3ghz, 4gbram, 500gb hdd, 32 lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmioutput, configurationwithwindows10 pro, office 12 and antivirus ( work station , operator station , one stand by as per spec ) , ems software , converter for intigration to ems systeam , 16 port ethernet switch with rack , 8 port ethernet switch with rack , smps , field instruments , room dp transmitter with three row display unit ( t&rh and dp ) , room temperature & rh transmitter , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 3c x 1.5 sq mm armoured copper cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for electrical items , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , hvac system , air cooled chiller units : supply , installation testing and commissioning of air cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; condenser coils as a mandatory requirement shall have a factory applied anti corrosive protective coating of electro deposited and baked flexible epoxy coating, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprene pad vibration isolators, integralrefrigerant piping and wiring, accessories as required and called for, automatic and safetycontrolsmountedincentralconsolepanelandailmountedonasteelframe.motorshallbesuitablefor 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a or equivalent ) . the noise level for each chiller should not exceed 80 dba at 1 meter, measured at any point from the chiller. inlet temp.of water 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceas permanufacturersdrawing.allms structurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price.microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection. note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. , capacity 60tr ( 2w + 1s ) chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , heat pump 150 kw ( 1w+1s ) , supply, installtion, testing and commissioning of water cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; water cooled condenser, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprenepadvibrationisolators, integral refrigerantpipingandwiring, accessoriesasrequiredandcalledfor, automatic and safety controls mounted in central console panel and ail mounted on a steel frame. motor shall be suitable for 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a / equivalent ) . thenoiselevelforeachchillershouldnot exceed80 dba, measuredat anypoint 1 metersfrom the chiller. hot waterinlettemperatureof450c, outlettemperatureofwater500c.chilledwaterinlettemp.ofwater 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceasper manufacturersdrawing.allmsstructurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expaansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price. microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection.note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. hot water inlet @ 45 deg c, outlet @ 50.0 deg c.chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , chilled / hot water pumps supply, installation, testing & commissioning of horizontal / verticle pumps. pump body : cast iron, impeller : stainless steel / aisi 316l. all pumps shall be aligned properly as required as per specifications.minimum efficiency of the pump shall be 75%. the pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply.the motor selected shall be energy efficient having efficiency ( class i ) at full load ranging between 91.5% to 94% in accordance with motor rating as per specification.vendor to check & confirm the motor ratings as specified for outdoor duty application consisting of: a ) pump and motor ( suitable for outdoor and continuous operation ) , b ) mounting frame & vibration isolators, c ) earthing of motor ( ip 55 ) & frame, d ) lifting & mounting of the pumps at locations as shown in drgs. ( at terrace level ) , e ) all accessories require i.e. flexibles, eccentric reducers and expanders, consumables etc., f ) insulation of the pumps and accessories as per the given specifications. , chilled water pumps , capacity:240usgpmhead 35m ( 1w +1s ) for air cooled chiller , capacity:106usgpmhead 35m ( 1w +1s ) for heat pump , hotwater pumps , capacity:180usgpmhead 35m ( 1w +1s ) , electrical panel for pumps for chilled and hot water supply installation and commissioning of electrical panel for pumps including:a ) logic controller with required software, b ) all mcbs, mccbs, vfds, vfd by pass etc as per require, c ) differential pressure sensors / transmitters with control wiring, d ) bms compatibility , electrical panel for pumps , control wiring between dpts and main controller / s , air separator supply , installation , testing and commissioning of 125 mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for chilled water with all assesories. , supply , installation , testing and commissioning of 100mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for hotwater with all assesories. , open type expansion tank supply , installation , testing and commissioning of 1000l ms tank with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding with make up water connection, over flow and drain provisions for chilled water with all necessary foundation , supply , installation , testing and commissioning of 1000l pvc tank with make up water connection, over flow and drain provisions for hotwater with all necessary foundation. , chilledwater piping: supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 150mm dia. ( 75 mm thick insulation ) , 125mm dia. ( 50mm thick insulation ) , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 65mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 32 mm dia ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , sitc of butterfly valves, required for chilled waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 125 mm ø , 100 mm ø , 80 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 40 mm ø , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , 80 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc fabricatedchilledwater manifoldfor ahus as below having chw requirement for chw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 100 mm ø , 50 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 80 mm ø , 40 mm ø , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 125 mm ø , 100 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hot water piping supplying, laying / fixing, testing and commissioning of following nominal sizes of hot water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , valves & instrumentssitc of butterfly valves, required for hot waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 80 mm ø , 50 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 50 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc fabricatedhotwater manifoldfor ahus as below having hw requirement for hw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 40 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 80 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hvac low side items air handling unit recirculation type ahu for classified systems ( iso 7 ) . sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 02 13260 cmh ( 7800 cfm ) with 11tr cooling & 26.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 03 16830 cmh ( 9900 cfm ) with 11tr cooling & 20.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 04 10200 cmh ( 6000 cfm ) with 9tr cooling & 12.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee section filter with flange type filter section with combination of eu 4, eu 5 filtersfilters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 01 6120 cmh ( 3600 cfm ) with 5.0tr cooling & 7.0kw heating capacity@ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 06 1700 cmh ( 1000 cfm ) with 2.0tr cooling & 3.0kw heating capacity @ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 07 11900 cmh ( 7000 cfm ) with 9.0tr cooling@ 100 sp with 2 motor ( 1 w+1s ) ( qa qc area ) , once through type ahu sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panelwith internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 05 13090 cmh ( 7700 cfm ) with 45tr cooling & 41.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , exhaust unit floor mounted horizontal type exhaust unit. sheet metal sectionalised cabinet type ahu in double skin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.63 mm gi & outer skin 0.63mm precoated giconstruction with 25mm thick puf insulation panel, suitable 20 micron filter, blower and motor, exhaust damper, vibration mounts etc with all necessary hardware. , veu 05 13430 cmh ( 7900 cfm ) @ 75sp motor: ( 1 w+1s ) , chilled water cassette / hi wall unit sitc of chilled water cassette unit withinfrared remote control, micro controller, drain pump & necessary supporting arrangement with ready made valve station complete with butterfly valves / gate valves , 2 way valves with actuators–strainer, pressure cum balancing valves. the entire skid shall be coated with zinc chromate primer coating and then painted with enamel paint.electrical cable connection from mcb / isolatorto cassette unitshall be done by hvac contractor. , 1.0tr ( cabin and passagearea ) , 3.0tr ( office area ) , decorative fcu: chilled water fan coil unit of double skin construction with compact cooling coil, multispeed fan motor, the blower shall be dynamicaly balanced and designed for silent operation, the filters shall be washable synthetic media type arranged for convenient cleaning and replacement, drain pan with pump . the actuator of modulating valve shall be provided with interface cards to receive 0 10v or 4 20 ma signal from minxon digital thermostat. unit complete with all necassary valves.the unit is supplied with corded remote controller of approved as per instruction and as directed by oic es , 2.0tr ( for ups and battery room ) ( 1w+1s ) , 1.0tr ( for storageroom ) , air filtration system hooded type hepa filters supply of hepa filter modules with ss 304 supplyperforated grill in crca powder coated finish side inlet type, with provision for dop, pressure drop measurement along with volume control damper and provision for a flange type hepa filters ( hepa filterh14 type ) including flexible connection. price also include the hepa filter. , size: 610 x 610 x150 mm , size: 450 x 450x150 mm , size: 305 x 305x150 mm , supply, installation, testing & commissioning of 25mm thick thermal insulated aluminium flexible duct of250mm dia duly supported at regular interval as per site requirement etc. complete as required as per specifications. , air distribution and control system ducting supply, fabrication, installation and testing of following sizes of aluminium metal ductingaluminium supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc. the frame shall slide over the duct ends to form flange connection. the flange connection shall be supplied with airtight seals. ducts shall be suitably reinforced using diagonal bends, distance pieces, etc.apermanentnon etching, siliconefreeelasticsealingmaterialshallbeused.exposed duct should have provide al. cladding.duct leak test to carry out after instalttion. , 22 g sheet , 20 g sheet , 18 g sheet , insulation , supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber ( class o ) insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. exposed duct should beprovide with 26 g al cladding. , 32 mm thick on supply air duct , 19 mm thick on return air duct , supply installation of aluminium extruded powder coatedvolume control damper constructed in 18g gi frame and 18g blades complete with handle for main and branch ducts. , al.sq.fourwaytypeairdiffuser ( supply&return ) with18g, g.i. powdercoatedboxwithaluminumcollar damper: , miscellaneousitems , fire damper: supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch and return air path as and where required of required sizes i / c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. , fire damper , actuator , supply grills , supplying & installtion of perorated type grill for return air riser with 1.2mm thick gipc capsulation perforations with all necessary fixing arrangement. , gi powder coated fresh air louvre with filterand brid screen , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the rooms , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the ahus. , on site validation and testing of the complete clean room system:after completion of e&c of all equipment and accessories, validation test shall be conducted as described below: testing & validation as per iso 14644:2001 standards ( velocity, particulate count, temp, humidity, filter, integrity tests to be carried out at the site ) by 3rd party. a comprehensive on site validation and certification service for clean room installation is in the scope. these includes leak detection, clean room level measurement and certification, air flow pattern analysis, dead zone identification and elimination and comprehensive documentation with regard to maintenance & validation procedure. , followingvalidation&testingoftheinstalledclean roomduringfinalcommissioningoftheabovecleanroom project: cleanliness levels as per iso 14644 air quality monitoring particle size efficiencies and quantity count airborne particulate contamination monitoring air velocity measurement & air flow quantity measurement temperature control range tests humidity control range tests filter pressure drop measurements air flow pattern and strength light level checks at 1m working height in clean room room pressurization , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for hvac system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , gas distribution system , supply and installtion of high pressure gas manifold system ( manual ) for four cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , sitc of automatic control panel to transfer co2 between the manifold. , supply and installtion of high pressure gas manifold system ( manual ) for two cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , 1 / 2 ss 316l tube with necessary fittings and supports ss 316l , 1 / 4 ss 316l tube with necessary fittings and supports ss 316l , 1 / 2 ball valvess 316l , 1 / 4 ball valve ss 316l , sitc of gas control box with gauge regulator, needle valveand all other necessary fillting, hadware etc as per the requirement. , sitc of pvc tube with brass nozzle for providing the connection inside the lab with all necassry hadware, fitting etc as per instruction and as directed by oic es , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for gas distribution system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , cat ( b ) supply, installation, testing and commissioning of following equipment as per tendered specifications of cgmp centre of cellular immunotherapies at actrec , lab refrigerator – 625 ltsas per tendered specifications , clean room lab refrigerator – 625 ltsas per tendered specifications , blood bank refrigerator customized 625 lts as per tendered specifications , automated closed cell processing system as per tendered specifications , cell expansion system as per tendered specifications , mobile processing system ready kart as per tendered specifications , controlled freeze system ( rate controlled freezer ) as per tendered specifications , blood bag centrifuge – 8 bags as per tendered specifications , water bath high precision as per tendered specifications , automated thawer for bags as per tendered specifications , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) as per tendered specifications , air jacketed co2 incubator as per tendered specifications , automated cell counter as per tendered specifications , inverted microscope as per tendered specifications , inverted microscope as per tendered specifications , floor model high speed centrifuge ( bags & vials ) as per tendered specifications , 100 ltr refrigerator as per tendered specifications , sterile connecting device type aas per tendered specifications , sterile connecting device type bas per tendered specifications , hand sealeras per tendered specifications , magnetic based cell separation system cts grade dynamagnet as per tendered specifications , bench top minispin as per tendered specifications , high performance centrifuge for elutriationas per tendered specifications , table top model high speed centrifuge as per tendered specifications , bsl cabinet ( bsl 2* ) as per tendered specifications , ultracentrifuge as per tendered specifications , bench top centrifuge as per tendered specifications , microplate spectrophotometer as per tendered specifications , real time pcr as per tendered specifications , gel dock system as per tendered specifications , end point pcr proflex as per tendered specifications , flow cytometer facs cell sorteranalyzer as per tendered specifications , endotoxin detection system as per tendered specifications , liquid nitrogen tank bags as per tendered specifications , liquid nitrogen tank vials as per tendered specifications , deep freezer 80 cas per tendered specifications , deep freezer 20 to 40 c as per tendered specifications , deep freezer 20 c as per tendered specifications , deep freezer 80 c as per tendered specifications , cryoshipper as per tendered specifications , cat ( c ) cmc after expiry of warranty period for following equipment , lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 1st year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 2nd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 3rd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 4th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 5th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 1st year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 2nd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 3rd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 4th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 5th year after expiry of warranty period of 2 years , cell expansion system cmc for 1st year after expiry of warranty period of 2 years , cell expansion system cmc for 2nd year after expiry of warranty period of 2 years , cell expansion system cmc for 3rd year after expiry of warranty period of 2 years , cell expansion system cmc for 4th year after expiry of warranty period of 2 years , cell expansion system cmc for 5th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 1st year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 2nd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 3rd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 4th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 5th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 1st year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 2nd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 3rd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 4th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 5th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 1st year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 2nd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 3rd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 4th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 5th year after expiry of warranty period of 2 years , water bath high precision cmc for 1st year after expiry of warranty period of 2 years , water bath high precision cmc for 2nd year after expiry of warranty period of 2 years , water bath high precision cmc for 3rd year after expiry of warranty period of 2 years , water bath high precision cmc for 4th year after expiry of warranty period of 2 years , water bath high precision cmc for 5th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 1st year after expiry of warranty period of 2 years , automated thawer for bags cmc for 2nd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 3rd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 4th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 1st year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 2nd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 3rd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 4th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 5th year after expiry of warranty period of 2 years , automated cell counter – 625 lts cmc for 1st year after expiry of warranty period of 2 years , automated cell counter cmc for 2nd year after expiry of warranty period of 2 years , automated cell counter cmc for 3rd year after expiry of warranty period of 2 years , automated cell counter cmc for 4th year after expiry of warranty period of 2 years , automated cell counter cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type a cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type b cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 5th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 1st year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 2nd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 3rd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 4th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 5th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 1st year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 2nd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 3rd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 4th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 5th year after expiry of warranty period of 2 years , hand sealer cmc for 1st year after expiry of warranty period of 2 years , hand sealer cmc for 2nd year after expiry of warranty period of 2 years , hand sealer cmc for 3rd year after expiry of warranty period of 2 years , hand sealer cmc for 4th year after expiry of warranty period of 2 years , hand sealer cmc for 5th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 1st year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 2nd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 3rd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 4th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 5th year after expiry of warranty period of 2 years , bench top minispin cmc for 1st year after expiry of warranty period of 2 years , bench top minispin cmc for 2nd year after expiry of warranty period of 2 years , bench top minispin cmc for 3rd year after expiry of warranty period of 2 years , bench top minispin cmc for 4th year after expiry of warranty period of 2 years , bench top minispin cmc for 5th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 1st year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 2nd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 3rd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 4th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 5th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 1st year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 2nd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 3rd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 4th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 1st year after expiry of warranty period of 2 years , ultracentrifuge cmc for 2nd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 3rd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 4th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 5th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 1st year after expiry of warranty period of 2 years , bench top centrifuge cmc for 2nd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 3rd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 4th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 5th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 1st year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 2nd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 3rd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 4th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 5th year after expiry of warranty period of 2 years , real time pcr cmc for 1st year after expiry of warranty period of 2 years , real time pcr cmc for 2nd year after expiry of warranty period of 2 years , real time pcr cmc for 3rd year after expiry of warranty period of 2 years , real time pcr cmc for 4th year after expiry of warranty period of 2 years , real time pcr cmc for 5th year after expiry of warranty period of 2 years , gel dock system cmc for 1st year after expiry of warranty period of 2 years , gel dock system cmc for 2nd year after expiry of warranty period of 2 years , gel dock system cmc for 3rd year after expiry of warranty period of 2 years , gel dock system cmc for 4th year after expiry of warranty period of 2 years , gel dock system cmc for 5th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 1st year after expiry of warranty period of 2 years , end point pcr proflex cmc for 2nd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 3rd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 4th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 5th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 1st year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 2nd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 3rd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 4th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 5th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 1st year after expiry of warranty period of 2 years , endotoxin detection system cmc for 2nd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 3rd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 4th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , cryoshipper cmc for 1st year after expiry of warranty period of 2 years , cryoshipper cmc for 2nd year after expiry of warranty period of 2 years , cryoshipper cmc for 3rd year after expiry of warranty period of 2 years , cryoshipper cmc for 4th year after expiry of warranty period of 2 years , cryoshipper cmc for 5th year after expiry of warranty period of 2 years...

Vasai Virar City Municipal Corporation - Maharashtra

32090624 tender for fixing of auto mensfaluar panel, timer panel, electrification work, electrical arrangement (fan, tubelight, point wiring, cable arrangement, installation of air conditioner, distribution panel, earthing work, electrification work in toilet....

Indian Army - Maharashtra

32040461 expression on intrest of tank t 72 spares as per appx a , purchase of spares of t 72 , 10224430 z6 / r72 4720 014857 ( bk6 450 111 ) hose assy ( bk6 450 111 ) , 10224438 y3 / r72 5970 000057 tape insulating , 10224441 z6 / r72 misc 175 24 009 sb plate , 10224454 z6 / r72 misc 172 77 0216 or 3650 763 sealing ring ( 8x2 ) , 10224456 z6 / r72 misc 172 77 0224 or 3650 763 sealing ring ( 25x2 ) , 10224461 y3 / r72 5970 910061 sleeving elect pvc 2mm id & wall thk , 10224462 y3 / r72 5970 910100 sleeving electrical pvc 3 5 mm id , 10224469 z6 / r72 4615 731 201 75 socket 4vshlg4411conectr circulr shilded , 10224471 z6 / r72 misc 172 77 0233 or 3650 763 sealing ring ( 22x2 ) , 10224491 z6 / r72 misc 4565 730 201 44 / 1 contactor , 10224508 z6 / r72 5620 001220 glass sheet ( 172 74 379 ) , 10224526 z6 / r72 misc bk8 366 233 limiter , 10224569 y3 / r72 5970 910126 slving elec pvc 4.5mm &0.5 mm tick wite , 10224584 z6 / r72 4680 730 101 50 relay tke 52 pd1 , 10224632 z6 / r72 bk 2 968 097 replenishing tank traverse , 10224757 z6 / r72 misc bs6 450 141 hose , 10224831 z6 / r72 5310 024135 clamp loop ( 172 74 402 ) , 10224834 z6 / r72 bs 10 tm u 000 power unit , 10224917 z6 / r72 misc t 72 bs6 450 086 hose , 10224948 z6 / r72 4720 014858 hose assy ( bk6 450 241 ) , 10224961 z6 / r72 172 74 001 3a housing , 10225007 z6 / r72 5940 008118 terminal lug, 520 08 003 01 , 10225022 z6 / r72 5940 008117 terminal lug ( 520 08 003 ) , 10225031 z6 / r72 5940 008116 terminal lug , 10225046 z6 / r72 5342 000004 anchor plate steel strapping , 10225295 z6 / r72 zd bsp 003 printed wiring board , 10225366 z6 / r72 gost 1491 72 ( oh 430 ) screw m3 6gx16.36.016 , 10225375 z6 / r72 gost 17475 72 ( m4x20.48.016 ) screw ( m4x20.48.016 ) , 10225438 z6 / r72 misc bk8 949 375 safety washer , 10225445 z6 / r72 misc 4048 001 897 04 capacitor fxd mplr 0 micro f101% 63w , 10225505 z6 / r72 5330 374899 gasket ( 432 71 096 ) , 10225514 z6 / r72 5340 174553 clamp loop, 520 09 002 06 , 10225563 z6 / r72 misc bm3 6gx6.36 016 screw , 10225598 z6 / r72 5340 72 023 7627 clamp loop ( 172 74 356 ) , 10225619 z6 / r72 5340 72 023 7629 clamp loop ( 172 74 409 ) , 10225737 lv1 / r72 172 85 008 hose , 10225900 z6 / r72 5340 174550 clamp ( 172 74 418 b ) , 10225909 z6 / r72 5340 72 023 8029 clamploop ( 172 74 390 ) , 10225986 lv1 / r72 tu 005 6016 80 ( tl=0.085mtr ) hose 40u142 1, bore dia 142mm, wall thk 5 , 10225989 z6 / r72 5340 72 023 7646 clamp loop ( 150 91 970 ) , 10226185 z6 / r72 misc be4 0816 002 lamp holder , 10226238 z6 / r72 misc bd8 385 002 spring , 10226322 z6 / r72 5999 048840 contact electrical ( 172.74.145 sb ) , 10226337 z6 / r72 5330 026262 gasket ( 172 74 324 ) , 10226342 z6 / r72 misc by1 005 gasket , 10226398 z6 / r72 5310 024129 clamp loop ( 520 09 001 15 ) , 10226458 z6 / r72 5306 059852 bolt fork end ( r6t 135 ) , 10226515 z6 / r72 520 09 001 18 / 1 clamp 24x7 , 10226517 z6 / r72 5340 176433 bracket angle ( 172 74 334 1 ) , 10226532 z6 / r72 misc 4 65g 06 washer , 10226546 z6 / r72 5340 72 023 7644 clamp 6x7 ( 520 09 001 02 ) , 10226548 z6 / r72 5340 176432 bracket angle ( 172 74 333 1 ) , 10226568 z6 / r72 520 07 005 02 / 1 washer 10 , 10226578 z6 / r72 misc 3650 763 705 31 sealing ring 18x2 , 10226588 z6 / r72 5340 72 023 7643 clamp, loop ( 520 07 001 4 ) , 10226598 z6 / r72 misc 3 01 08kp 016 washer , 10226683 z6 / r72 5340 176205 catch clamping ( 54 39 034 1 ) , 10226712 z6 / r72 5340 176204 bracket double angle ( 172 74 328 1 ) , 10226732 z6 / r72 5340 174773 lever ( 172 74 078sb 1 ) , 10226750 z6 / r72 172 74 114sb ( roh 350 ) rotor assy , 10226880 lv1 / r72 4720016030 hose ( drg no 175 85 032 ) , 10226957 z6 / r72 em 1 000 ty ( roh 1228 ) electromagnet em 1 , 10227160 z6 / r72 54 26 349 2a ( roh 3357 ) boot , 10227237 lv1 / r72 5306057008 bolt 3m12x1.25 6gx20.66.016 , 10227457 z6 / r72 misc bk2 959 058 cylinder head , 10227474 z6 / r72 misc bk2 503 057 switch box , 10227495 z6 / r72 misc bk2 355 023 adjustment unit , 10227726 z6 / r72 misc bc8 020 108 housing , 10227922 lv1 / r72 5306057012 bolt 3m16x40 66 016 , 10228016 z6 / r72 misc 113 172 014 gasket , 10228181 z6 / r72 misc kp 50 042 gasket , 10228324 z6 / r72 misc aci 01 05 gasket , 10228425 z6 / r72 misc p10t 118 gasket , 10228437 z6 / r72 misc ost3 1396 72 ( 40x2 ) sealing ring upn 3012 size 40x2 , 10228502 z6 / r72 misc ba 20 ic 002 cover , 10228512 z6 / r72 misc ost3 1396 72 ( 36x2 ) sealing ring upn 3012 72 ( 36x2 ) , 10228530 z6 / r72 misc ost3 1396 72 ( 33x2 ) sealing ring upn 3012 size 33x2 , 10228559 z6 / r72 misc ost3 1396 72 ( 26x2 ) sealing ring upn 3012 size 26x2 , 10228577 z6 / r72 misc ost3 1396 72 ( 45x2 ) sealing ring upn 3012 size 45x2 , 10228683 z6 / r72 misc ost3 1396 72 ( 12x2 ) sealing ring upn 3012 size 12x2 , 10228705 z6 / r72 misc ost3 1396 72 ( 11x2 ) sealing ring upn size 11x2 , 10228811 z6 / r72 kp 150 041 gasket , 10228895 lv1 / r72 5306056887 bolt m6 6g x12 .66 ( gost 7805 70 ) , 10229276 z6 / r72 misc gost 7805 70 ( z6 ) bolt , 10229565 lv1 / r72 5306056997 bolt m10 6gx20 66.016 , 10229646 z6 / r72 misc bc8 642 004 ganze , 10229652 z6 / r72 misc p3 150 060 rubber dust cap , 10229672 z6 / r72 misc p3 150 050 cap , 10229692 z6 / r72 misc p11 5 041 cap , 10229703 z6 / r72 misc p11 013 gasket , 10229777 n1 / r72 1015 004025 pressure block assy ( complete assy ) , 10229800 lv1 / r72 5306056991 bolt 3m10 6gx35 88 38xc 016 , 10229837 c2 / r72 172 22 038 ( oh 912 ) pin ( mounting of mgpkt ) , 10229889 z6 / r72 misc bsp1 103 gasket , 10229909 z6 / r72 misc bsp1 112 cover , 10229942 z6 / r72 vk6 430 068 cap red assy , 10230038 x2 / r72 4615 730 105 65 ( roh 820 ) connector fixed ( plug 7 pin ) , 10230090 z6 / r72 misc br10tm y 000 regulating unit , 10230156 z6 / r72 misc bc8 656 178 plug , 10230200 n1 / r72 2a26 07 49 inner packing ring ( recuperator ) , 10230229 n1 / r72 1015 002861 or 2540 001371 lever latch ( for breech mech ) , 10230239 x2 / r72 172 71 093 sb ( roh 97 ) mounting of switch , 10230244 z6 / r72 bk2 369 113 unit gyro , 10230247 n1 / r72 1015 002925 mounting of cell lifting mech , 10230441 z6 / r72 misc bc8 640 022 glass panel , 10230461 z6 / r72 5340 72 023 7501 clamp loop ( 150 31 1148 ) , 10230588 n1 / r72 1015 003471 tray ( drg no 2a26sb 02 32sb ) , 10230902 z6 / r72 misc r10t 177 cap , 10230992 z6 / r72 misc r10t 142 resistor p4 , 10231004 z6 / r72 5340 177879 cover access ( 172 74 380 ) , 10231314 n1 / r72 1015 003098 shaft ( 172.18.064 ) , 10231613 z6 / r72 misc 8dc 946 027 nut , 10231653 z6 / r72 5330 383947 retainer packing , 10231736 n1 / r72 1015 003278 accelerator ( cradle ) , 10231750 z6 / r72 5330 381519 gasket ( ring 172 74 433 ) , 10231756 n1 / r72 2a26 09 45 ( aroh 350 ) bracked ( cradle ) , 10231767 z6 / r72 misc pp 172 002 toothed gear , 10231775 n1 / r72 2a26 09 97 ( roh 349 ) strap ( cradle ) , 10231796 n1 / r72 2a26 10 201 ( aroh 394 ) strap ( guard ) , 10231832 z6 / r72 5330 379984 gasket special round ( 432 71 319 ) , 10231837 n1 / r72 2a26 m2 sb 21 5 ( aroh 524 ) encaesd micro switches ( elevation mech ) , 10231855 z6 / r72 misc 000 360 007 tu micro switch mp1 1 ( tds ) , 10231988 z6 / r72 misc aci 10 02 bush , 10232008 n1 / r72 1015 004141 mounting of rotary conveyer , 10232062 n1 / r72 1015 007994 clamp mtg , 10232071 z6 / r72 misc pus 10 011 cover , 10232112 n1 / r72 10vp 22 ax20 lock pin ( breech mech ) , 10232131 n1 / r72 1615 001667 housing assy ( 2a46 sb21 26sb ) , 10232213 lv1 / r72 432 70 609 2 plug , 10232283 z6 / r72 misc b15 955 005 cap , 10232300 z6 / r72 misc b15 955 004 cap , 10232303 n1 / r72 2a46 cb 21 7sb ( aroh 519 ) gear ( elevation mech ) , 10232346 z6 / r72 misc pco 452 045ty ( pc10 ) relay p pc10, pc4 529 031 06 01 , 10232634 z6 / r72 misc zd bsp 006a printed wiring board , 10232657 z6 / r72 misc zd bsp 006 printed wiring board , 10232677 z6 / r72 misc geo 364 140 tu plug 2 rmg 1820 7sh 1ye2 , 10232692 z6 / r72 misc bk4 024 066 control mechanism , 10232711 z6 / r72 misc amt10 060 contact set , 10232731 z6 / r72 misc amt10 026 bush , 10232737 z6 / r72 misc amt10 023 screw , 10232758 z6 / r72 misc amt 10 024 gasket , 10232775 z6 / r72 misc amt 10 021 gasket , 10232789 z6 / r72 pco.452.045ty relay p 9.pc4.529.029 00.01 , 10232833 z6 / r72 misc 8dc 994 000 cotter pin , 10232851 z6 / r72 misc 8dc 900 044 screw , 10232893 z6 / r72 misc bk5 689 281 coil , 10232900 z6 / r72 pb4 522 000 relay rp 5 , 10233353 n1 / r72 172 27 195 lever ( for cartridge base disposal ) , 10233376 z6 / r72 misc gost 13943 68 sealing ring upn 3012 size 75x2 , 10233424 n1 / r72 175 18 075sb ( roh 788 ) body lock ( rotary conveyer ) , 10233454 n1 / r72 175 20 015 ( roh 836 ) gun complete with spta and slip covers , 10233496 n1 / r72 172 18 084 cable ( rotary conveyer ) , 10233500 z6 / r72 misc t 72 bk6 450 225 pipe , 10233526 n1 / r72 1015 004132 ring ( a51203.1 ) , 10233541 z1 / r72 pf 0 450 047ty relay pec 47 , 10233546 c2 / r72 172 22 004cb ( oh 914 ) deflector chute lower , 10233557 c2 / r72 166 45 396 1 ( oh 920 ) spring ( mounting of mgpkt ) , 10233559 z1 / r72 rs 0 400 0latu relay , 10233589 z1 / r72 rso 452 049wt ( oh 401612 ) relay , 10233681 c2 / r72 1005 561014 rear slide assembly ( 6p7 k.07.000 ) , 10233689 c2 / r72 1005 561012 front slide assembly ( 6p7 k.09.000 ) , 10233796 z1 / r72 misc rf4 500 409 p2 relay ras 47 rl1, rl2, rl3 , 10233802 z6 / r72 misc t 72 bs8 656 132 plug , 10233816 z1 / r72 misc rf4 500 408 p2 relay ras 47 rl3 , 10233835 z1 / r72 misc ras 10 relay r6 & r7 , 10233843 z6 / r72 misc gost 11371 78 ( 4x1.601.016 ) washer ( 4x1.601.016 ) , 10233855 z1 / r72 misc r10t 027 transformer , 10233875 z1 / r72 misc r10t 018 choke dr , 10233893 z1 / r72 misc oao 339 054ty transister 2t 825 or 2n 6052 5 , 10233913 z1 / r72 misc kr175 3c 092 board , 10233943 z6 / r72 misc pus 15r 430 relay with angle piece , 10233963 z1 / r72 misc itxo 03363 3004ty transistor mp 265 , 10233984 z1 / r72 sel 53677 switch assy , 10234003 z1 / r72 twt 72 / cemi / a 57 ( oh 401613 ) diode , 10234090 z6 / r72 misc pus 15r 800 panel with elements , 10234099 z6 / r72 misc pus 15r 400 panel with elements , 10234250 z6 / r72 misc pus isr 600 time relay , 10234452 z1 / r72 misc gost 10450 78 relay tke54 relay ( tke 54 17591 ) , 10234466 z6 / r72 4030 003736 hook ( 172 74 323 ) , 10234494 z1 / r72 misc gao 364 108tu ( w2 ) receptacle shrg 28 p7 ash9 ( w2 ) , 10234517 z1 / r72 misc efy 18 & 16 transistor ( pnp ) , 10234578 z1 / r72 misc cm3 362 018ty diode d 223a , 10234595 z1 / r72 misc cm3 362 012ty ( d814 ) diode d 814b stabliser , 10234791 x2 / r72 misc gost 11371 78 ( roh 512 ) plug ( pwabpb6 ) , 10234813 x2 / r72 misc gost 3128 70 ( roh 510 ) plug ( 2 pmg 18b7 sh 1k2 ) , 10234869 z6 / r72 r10t 143 ( r8 ) resistor r8 , 10234889 z6 / r72 rus bk8 653 197 pipe connector bolt , 10235090 z6 / r72 misc gost 10450 78 ( m39x1.5 ) cover m39x1.5 , 10235186 z6 / r72 misc gost 17475 72 ( m5x20.48.016 ) screw ( m5x20.48.016 ) , 10235199 x2 / r72 h10 481 017 fuse pm 2a , 10235206 z6 / r72 misc gost 17475 72 screw m4 6gx12.36.016 , 10235355 z6 / r72 r 10 t 116 cap , 10235469 z6 / r72 misc bc6 112 083 body , 10235489 z6 / r72 misc bc6 112 084 body , 10235519 z1 / r72 misc ojo 467 107tu ( r3 ) resistor omlt 2 180+ / 10% r3 , 10235593 z6 / r72 misc bc2 958 028 ( 16x2 ) sealing ring ( be dp 3012 ) size 16x2 , 10235620 z1 / r72 misc pqo 450 047ty relay ( p3c 47 ) magnetic relay p7c 47 , 10235803 z6 / r72 misc bc6 110 105 housing , 10235815 y3 / r72 misc cwpg36p15ew3 connector , 10235835 x2 / r72 misc cwp 60p 453w3 or cshpg 60p 45ash3 connector , 10235856 x2 / r72 misc cshd 32p 10a sh4 plug ( w1 ) , 10235895 x2 / r72 misc 2pmgd24b19w1e2b or 2pmg24b19sh1e2b connector , 10235961 z6 / r72 misc bc5 890 002 valve , 10236010 z1 / r72 misc ozho 464 023ty capacitor 33 mfd 35v + / 10% , 10236032 z1 / r72 misc oxo 467 107ty ( 3k ohms ) resister 3k ohm + / 1% 1 / 4w + / 10% , 10236055 z6 / r72 misc bc2 958 028 ( 22x2 ) sealing ring ( bc dp 3012 ) size 22x2 , 10236075 z6 / r72 misc bc5 768 001 coil , 10236178 z6 / r72 misc bc5 890 004 valve , 10236198 z6 / r72 misc gost 10450 78 ( m36x1.5 ) cover m36x1.5 , 10236283 z6 / r72 misc d 815 a voltage stabilizing diode , 10236315 lv1 / r72 5305099481 screw bm3 6gx40.46.016 , 10236322 z6 / r72 misc csn 021101 25 bolt m 8x35 , 10236430 z6 / r72 misc emt 81m 080 01 contact system , 10236440 z6 / r72 misc gost 10450 78 ( 8.04.019 ) washer ( 8 04 019 ) , 10236479 z6 / r72 misc g0st 1491 72 ( m3x8.48.016 9 ) screw ( m3x8.48.016 9 ) , 10236489 z1 / r72 misc 2k3 365 059tu transistor p307v , 10236498 z6 / r72 misc gao 364 108tu receptacle shrg 40 p 16 sh2 ( w1 ) , 10236538 lv1 / r72 4820057794 cock ( drg no 172 36 031 sb 1 ) , 10236552 z6 / r72 misc gost 10450 78 ( 2mp+2 ) cover ( 2pm +2 ) , 10236565 z1 / r72 geo 364 140 ty ( 2pm 18etw 1e 26 ) plug 2pm18etw 1e 26 , 10236574 z6 / r72 misc d816a stlabilizer diode c2 & cd , 10236599 lv1 / r72 4820057880 valve ( drg no 175 36 029sb ) , 10236602 z1 / r72 5961 000375 transistor ( cdil 2n 3019 ) , 10236770 z6 / r72 misc wt 4602 33 73 diode , 10237014 n1 / r72 2a46 21 76 ( aroh 523 ) handle ( elevation mech ) , 10237030 z6 / r72 misc emt 81 019 2 adjusting washer , 10237093 z6 / r72 misc gost 17475 80 screw bm5 screw bm5x14 36 016 , 10237136 lv1 / r72 5305099869 screw bm5 6gx55.46.016 , 10237237 z1 / r72 misc 450 033ty relay ( p3c 48 a b ) , 10237385 z1 / r72 493 365 013ty transistor 2t 6085 or 2n 2219 2t6085 , 10237389 z6 / r72 misc gost 17475 80 ( bm4.6gx16.36.016 ) screw bm4 6gx16 36 016 , 10237390 lv1 / r72 4730078958 coupling ( drg no 432 66 136 ) , 10237416 z6 / r72 misc emt 81 013 spring , 10237425 z6 / r72 misc emt 81 008 cover , 10237447 z1 / r72 misc uzh3 362 018 transistor ( kd 617 ) , 10237507 z1 / r72 misc uzh3 362 035ty diode 2d 202y , 10237532 z6 / r72 misc gost 1491 80 ( bm1.6gx16.36.016 screw bm1 6gx16 36 016 , 10237559 z6 / r72 misc gost 1491 72 / 1 screw m8 6gx25 36 019 , 10237713 z6 / r72 misc gost 17475 80 ( bm4.6gx12 36 016 ) screw bm4 6gx12 36 016 , 10237834 lv1 / r72 5310238941 spring washer 5 01 , 10237836 z6 / r72 misc gost 1491 72 ( m4x25.48.016 ) screw ( m4x25.48.016 ) , 10237844 n1 / r72 2a46 21 77 ( aroh 521 ) nut ( elevation mech ) , 10237904 z1 / r72 1 oq3 365 035ty transmitter 2t 208m or 2n 2904a , 10238000 z6 / r72 misc gost 1491 80 screw bm2.6g screw bm2 6gx10 48a 016 , 10238114 z1 / r72 misc tadiran2020 09060 20 cg 409 ( sh ) 2.75m shield rf cable , 10238126 z1 / r72 misc 2056 09570 00 operator leaflet , 10238136 z1 / r72 vk3 608 010 01 breast seitch with cord 2.2m , 10238315 z6 / r72 misc bk8 920 419 bolt , 10238349 z6 / r72 misc dbh 038 ring , 10238400 z6 / r72 misc emt 11 008 spring , 10238420 z1 / r72 w 613.365.007 ty transistor 2t 203a , 10238445 lv1 / r72 4820057557 usce valve ( drg no 172 83 100sb ) , 10238460 n1 / r72 2540 009245 body ( cell lifting mech ) ( 172 28 035 1a ) , 10238469 n1 / r72 5365 185048 bushing ( for guard ) ( 2a26 10 169 ) , 10238509 n1 / r72 6h8 810 274 ( aroh 859 ) plate ( mtg of gun 2a46 elevng mech ) , 10238524 z1 / r72 misc tadiran 2020 09050 88 cg 1773 ( 3.25m ) rf cable , 10238545 z6 / r72 misc gost 1491 80 ( bm3 6gxb 36 016 ) screw bm3 6gxb 36 016 , 10238565 z6 / r72 misc gost 1491 80 ( bm4 6gx10 48 016 ) screw bm4 6gx10.48.016 , 10238603 lv1 / r72 5305099875 screw, bm4 6gx50.46.016 , 10238793 z6 / r72 misc gost 1491 72 screw m3 6gx8.36.016 , 10238812 z6 / r72 misc gost 1491 72 ( m3 8.32.11 ) screw ( m4 8 32 11 ) , 10238813 z6 / r72 misc bk6 695 390 board , 10238831 z6 / r72 misc gost 1491 72 ( m3x8.48.016 ) screw ( m3 6gx8.48.016 ) ( m3x8.48.016 ) , 10238937 z6 / r72 misc gost 13943 68 ( 85x4 ) seaing ring be pii 3012 85x4 , 10238983 n1 / r72 5315 048726 cotter pin ( 2x16.06 ) ( gost 397 79 ) , 10239035 lv1 / r72 5305099879 screw, bm8x1.6gx18.46.016 , 10239081 x2 / r72 ty6309 73 contactor tkd 511 kod , 10239138 x2 / r72 misc kt 2061 ayz sealed toggle switch , 10239250 n1 / r72 a51066 108 screw ( m6x18 ) ( cradle ) , 10239270 n1 / r72 gost 17473 80 ( aroh 453 ) screw ( bm6 8gx16.66.c.06 ( elevation mech ) , 10239298 x2 / r72 tu7100 361 002 contactor tkd 111 dod , 10239330 c2 / r72 172 94 014sb ( aroh 1739 ) handle , 10239727 n1 / r72 2a46 09 14 ( aroh 346 ) cap ( cradle ) ( 2a46 09 14 ) , 10239746 n1 / r72 2a46 21 25sb ( oh 700 ) bushing ( elevation mech ) , 10239852 z7 / r72 ty 16 522 001 73 fuse 5a ( safety device ) , 10239900 n1 / r72 a51020 22 ( aroh 345 ) washer 8 ( cradle ) ( a 51020 22 ) , 10239993 z6 / r72 misc gost 1491 72 ( m4 6gx22 ) screw ( m 4 6gx22.48.016 9 ) , 10240009 x2 / r72 misc t 72 shdg 16p1ash4 plug ( w4 ) , 10240023 n1 / r72 9505 000212 ( roh 313 ) wire ( 2.o.c ) ( cradle ) ( gost 3282 74 ) , 10240080 x2 / r72 shdg 20p4ash8 ( roh 344 ) plug ( w1 ) , 10240108 n1 / r72 9125 74 ( aroh 157 ) wire 2.5mm ( breech mech ) , 10240127 n1 / r72 a51021 2 ( aroh 543 ) washer ( hand wheel assy ) , 10240369 z1 / r72 misc 2070 09232 00 ls 454 / u loudspeaker , 10240471 n1 / r72 3u8x16 lock pin ( breech mech ) , 10240553 n1 / r72 gost 9650 80 6 8f9x55 40 ( aroh 187 ) pin 6 8f9x55 40 ( shaft assy ) , 10240606 x2 / r72 shdg 32 p 123 sh 1 plug srt 32 p 123 s 1 , 10240726 c2 / r72 172 22sb.4 sb ( oh 890 ) mounting of coaxial machine gun pkt , 10240765 c2 / r72 172 22 5sb ( oh 916 ) bracket ( mounting of mgpkt ) , 10240786 c2 / r72 172 22 067 rod , 10240901 z6 / r72 misc 5dm 665 023 converter stator , 10240947 x2 / r72 misc wpg 5531ew3 connector , 10240967 x2 / r72 misc t 72 shdg 28p4ash5 plug ( w5 ) , 10240989 x2 / r72 misc t 72 shdg 28p1ash4 plug ( w3 ) , 10241018 z6 / r72 172 74 321 1 cover , 10241109 z6 / r72 172 77 068 pressure clamp lh , 10241125 z6 / r72 misc 6pp2 2ax30mm ok ppm lock pin , 10241127 z6 / r72 175 24 001 sb control equipment stabiliser 2z28m , 10241158 c2 / r72 172.22.002 sb ( oh 933 ) detent , 10241255 n1 / r72 m50 ( natural ) pipe 12 plastic ( componant ) , 10241316 n1 / r72slip ring with housing ( 2a46 sb21 27sb ) , 10241339 lv1 / r72 5140012722 slip cover ( drg no 54 28 123sb 3 ) , 10241369 z6 / r72 5340 72 023 7640 clamp ( 172 77 076 ) , 10241454 z6 / r72 misc gost 6402 70 ( 3.65g.05 ) washer 3.65g.05 , 10241524 z6 / r72 misc gost 6402 70 ( 12.65g.05 ) washer ( 12.65g.005 ) , 10241583 z6 / r72 misc gost 6402 70 ( h 1012 ) washer 4.65g.06 , 10241677 n1 / r72 5315 048705 cotter pin ( 2.5x20.016 ) , 10241691 z6 / r72 misc m4 611 5 8 016 nut , 10241770 z6 / r72 misc h3 4033 washer , 10241782 z6 / r72 misc ho 2466 58 / 2 collar 9086 size 20x38 , 10241809 z6 / r72 misc 541 007 tublar rivet , 10241813 z6 / r72 misc ho 2466 58 collar 9086 size 15x32 , 10241847 z6 / r72 2a26.10.256 or 2a26.sb 10.51 pressure block , 10241873 z6 / r72 misc 511 019 gasket , 10241964 n1 / r72 52 pt 412 10 97 ( aroh 393 ) stud ( guard ) , 10241997 z6 / r72 172 77 0226 sealing ring ( 32x2 ) 3650 733.019.36b , 10242054 lv1 / r72 5310 239032 nut m8 6h 10 38xc.016 , 10242062 n1 / r72 4730 080098 / 079864 / 079863 base ( guard ) / boss ( 2a26 10 296 ) , 10242126 z6 / r72 172 74 335 cover , 10242129 z6 / r72 misc bk8 639 218 shock absorber , 10242149 z6 / r72 misc bk8 639 217 shock absorber , 10242214 z6 / r72 3120 105013 bushing sleeve ( 172 74 348 ) , 10242234 z6 / r72 3120 105012 bushing sleeve ( 172 74 314 ) , 10242254 z6 / r72 3120 105011 bushing sleeve ( 172 74 223 ) , 10242457 x2 / r72 gao 364 126tu ( roh 861 ) socket 2 rm 24b 19 givi ( w3 ) , 10242584 x2 / r72 rus 90210 700 080 fuse 20a , 10243018 z6 / r72 misc bk7 840 663 gasket , 10243374 z6 / r72 misc gost 5496 78 ( 8x1.3x680 ) rubber tube 4c 8x1.3x680 , 10243492 z6 / r72 misc ho 360 011 micro switch ( d701 ) , 10243564 z6 / r72 5995 002517 wiring harness branched cable no 5 , 10243566 lv1 / r72 4720001712 hose connection ( drg no 175 31 034sb 1 ) , 10243804 z6 / r72 5961 952725 ( oh 2949 ) semi conductor device diode assembly , 10243842 z6 / r72 5975 065167 rod ( 172 74 207 2 ) , 10243970 z7 / r72 oko.360.028tu switch , 10243971 z6 / r72 gost 13943 68 / 2 sealing ring upn 3012 size 225x4 , 10244381 lv1 / r72 gost 792 67 ( l 450mm ) wire ko 1.6 ( l 450mm ) , 10244385 lv1 / r72 gost 792 67 ( l 350mm ) wire ko 1.6 ( l 350mm ) , 10244387 lv1 / r72 gost 792 67 ( l 150mm ) wire ko 1.6 ( l 150mm ) , 10244389 lv1 / r72 gost 792 67 ( arh oh 366 ) wire ko 1 2 ( l=350mm ) , 10245213 lv1 / r72 ost b3 4652 80 ( oh 3721 ) ring ct 21 14 4 , 10245225 lv1 / r72 5330 381622 seal oil ( drg no 432 70 617 ) , 10245475 lv1 / r72 gost 792 67 ( arh oh 343 ) wire ko 2 ( l=30mm ) , 10245523 lv1 / r72 5340178264 wire ko 1.2 ( spec no gost 792 67 ) , 10245544 lv1 / r72 gost 5496 84 pipe4.5x1.3x14 4c ( b dia4.5mmwalthk1.3mm , 10245555 lv1 / r72 gost 5496 78 / 2 pipe 10x2 ac , 10245845 lv1 / r72 em 26 15 000 tu electromagnet em 26 15 , 10246092 lv1 / r72 etu 500 ( oh 3443 ) ball 6, 35 200 ( gost 3722 81 ) , 10246152 lv1 / r72 etu 500 ( 7000107 ) bearing 7000107 , 10246300 lv1 / r72 etu 500 / 44 roller 3x19, 8 a5 ( gost 6870 81 ) , 10246381 lv1 / r72 etu500 hing bearing sh12 , 10246520 lv1 / r72 etu 500 / 18 roller 10x30 , 10247110 lv1 / r72 gost 9650 80 ( oh 3763 ) pin6 16f9x36.38xc.2.35.5 45.5chem oiled , 10247125 lv1 / r72 5315051412 lock pin 3u8x18 ( ost 3 2234 93 ) , 10247462 lv1 / r72 mod / veh / a / 2 / 96 mod of entrenchg plate to 175 88 002sba , 10247733 lv1 / r72 54.83.136sb snorkelmiddle section , 10247777 lv1 / r72 54.03.261 cover plate , 10247794 lv1 / r72 54.02.483 plate cover , 10247806 lv1 / r72 54.02.482 band , 10248000 lv1 / r72 5315052582 pin 2.4u8x10 ( spec no ost 3 2234 93 ) , 10248065 lv1 / r72 5315053164 spacer ( drg no 54 03 263 ) , 10248085 lv1 / r72 5315052419 contact ( drg no 432 23 214 ) , 10248308 lv1 / r72 5340015318 semi coupling ( drg no 175 36 067 ) , 10248339 lv1 / r72 5330396866 frame packing ( drg no 172 12 3sb ) , 10248363 lv1 / r72 5330396840 band packing ( drg no 172 12 012 ) , 10248760 lv1 / r72 54 83 158 label , 10248765 lv1 / r72 5365182766 adjusting washer ( drg no 172 47 243 ) , 10248913 lv1 / r72 6160000088 storage battery with basket , 10248996 lv1 / r72 54 36 240 or 54 36 240a bushing , 10249059 lv1 / r72 54 42 241 insulator , 10249068 lv1 / r72 54 42 243 gasket , 10249234 lv1 / r72 ap20 11121 145 filter , 10249312 lv1 / r72 5340015321 semi coupling ( drg no 175 36 068 ) , 10249345 lv1 / r72 cqa ( hv ) 5.88.000 modified entrenching plate , 10249484 lv1 / r72 gost 10450 78 ( oh 3830 ) under size washers 16.5x1.01.016 , 10249499 lv1 / r72 gost 11371 78 ( oh 3832 ) washer 10.32.46 , 10249561 lv1 / r72 5340180434 strap ( drg no 172 71 066sb ) , 10249667 lv1 / r72 54 83 25sb cup with frame , 10249694 lv1 / r72 ost3 408 70 ( oh 3799 ) clip 68 74 1 , 10250202 lv1 / r72 5365185406 bushing right hand ( drg no 172 11 171 ) , 10250257 lv1 / r72 5365185587 bushing ( drg no 172 70 408 ) , 10250649 lv1 / r72 5365185353 bushing, lh ( drg no 172 11 170 ) , 10251103 lv1 / r72 8115003070 box ( drg no 166 83 047 ) , 10251133 lv1 / r72 geo 344 108tu plug shrg 20p21sh6 , 10252172 lv1 / r72 gost 2526 70 / 14 nut m12x1.25 6h.04.20.016 , 10252278 lv1 / r72 gost 13942 86 ( t90 roh 3902 ) ring b60.xim.fos.oks.npm , 10252534 lv1 / r72 5855001779 mounting of vision device tvnye 4b , 10252555 lv1 / r72 gost 17473 80 ( oh 3638 ) screw am2 6gx12.46.016 , 10252564 lv1 / r72 gost 17473 80 ( oh 3639 ) screw am2 6gx14.46.016 , 10252578 lv1 / r72 gost 17473 80 ( oh 3640 ) screw am2 6gx16.46.016 , 10252672 lv1 / r72 5330387946 gasket ( drg no 155 22 015 ) , 10252749 lv1 / r72 5330389423 gasket ( drg no 175 32 109 1 ) , 10252787 lv1 / r72 gost 3032 76 ( oh 3698 ) nut m8 6h.45l 1.016 , 10252813 lv1 / r72 gost 3282 74 / wire 3.0.ch or 3.0.s , 10253136 lv1 / r72 54 26 657 strap , 10253352 lv1 / r72 5340182336 clip ( drg no 172 93 225sb ) , 10253976 lv1 / r72 gost 792 67 / 1 wire ko 1.2 , 10254238 lv1 / r72 gost 792 67 / wire ko 2 l=25mm , 10254483 lv1 / r72 ety 500 / 13 bearing 6 1000818 b size 90x115x13mm , 10264535 lv1 / r72 175 85 037 plug , 10264678 lv1 / r72 175 70 367 01 gasket , 10264708 lv1 / r72 175 70 367 02 gasket , 10264778 lv1 / r72 175 70 366 seal oil , 10264840 lv1 / r72 1385000025 shield ( drg no 176 34 035 ) , 10264919 lv1 / r72 175 70 368 gasket , 10264941 lv1 / r72 175 85 036 gasket , 10265293 lv1 / r72 175 83 025sb turn buckle , 10265566 lv1 / r72 172 31 296 support , 10265847 lv1 / r72 175 37 039 spindle , 10265867 lv1 / r72 175 36 063 a or 175 36 063b body , 10266244 lv1 / r72 175 36 017sb boiler , 10266254 lv1 / r72 2510008561 panel instruments , 10266310 lv1 / r72 2520013189 seat transmission gear unit , 10266314 lv1 / r72 155 26 489sb holder assy , 10266315 lv1 / r72 2510008584 mtg of rh hatch door drive ( 172 17sb ) , 10266325 lv1 / r72 175 70 387 bracket , 10266373 lv1 / r72 175 70 400 gasket , 10266406 lv1 / r72 2510008692 spring ( drg no 172 36 217 ) , 10266670 lv1 / r72 175 36 024sb a pump , 10266782 lv1 / r72 432 62 042 1 or 434 62 064 valve slide , 10266973 lv1 / r72 172.91.713 1 adapter , 10267248 lv1 / r72 172.83.207 a brace , 10267389 lv1 / r72 175.60.079 nut , 10267428 lv1 / r72 175.60.062 cover , 10267692 z6 / r72 sel 53658 light panel assy , 10267824 lv1 / r72 175 02 064sb 2 shutters outlet , 10268129 lv1 / r72 172 93 389 01 cover plate , 10268367 lv1 / r72 175.36.010sb clamp , 10268406 lv1 / r72 175.36.021sb blower with pump , 10268452 lv1 / r72 172.61.017sb body , 10268460 lv1 / r72 172 33 145sb pipe , 10268574 lv1 / r72 172 62 133 cam, right hand , 10268582 lv1 / r72 4140003408 fan ( drg no 172 38 006sb ) , 10268678 z7 / r72 rus olf std 130 02 slotted found nut m3 6h , 10268871 lv1 / r72 175 70 072 carrier , 10268889 lv1 / r72 172 91 143sb 1a bracket , 10268911 lv1 / r72 175 70 153sb strap , 10268932 lv1 / r72 4310003839 valve ( drg no 172 87 045sb 4 ) , 10269010 lv1 / r72 172 91 003sb 5 stowage of spta turret assy , 10269452 lv1 / r72 175 70 006 shield , 10269529 lv1 / r72 172 23 011 or 432 23 149 2 spring , 10269596 lv1 / r72 172 23 007sb body , 10269684 lv1 / r72 172 23 002sb mechanism turret traversing manual , 10270107 lv1 / r72 172 93 001sb 5 mounting of racks in hull , 10270240 lv1 / r72 155 22 017 rubber ring , 10270334 lv1 / r72 172 71 135 bracket , 10270893 lv1 / r72 172 93 211sb bracket , 10270983 lv1 / r72 172 36 082sb filter , 10271022 lv1 / r72 172 36 078sb vorfex generator with filter , 10271041 lv1 / r72 172 36 072sb head boiler , 10271212 lv1 / r72 172 70 304 clamp , 10271414 lv1 / r72 175 41 098 ring universal joint oil seal , 10271418 lv1 / r72 175 60 174 bolt , 10271996 lv1 / r72 172 70 336a bracket , 10272070 lv1 / r72 172 70 552 cover , 10272122 lv1 / r72 172 36 197 boom , 10272229 lv1 / r72 172 36 094 pipe union , 10272283 lv1 / r72 172 70 490 cover , 10272309 lv1 / r72 172 70 496 ring , 10272940 v5 / r72 au 8 684 360 gasket 143x20x0.25 board , 10273152 z6 / r72 rsg 10m 037 bolt , 10273342 lv1 / r72 2910008404 nozzle ( drg no 432 36 183 ) , 10273481 lv1 / r72 2930002938 upright ( drg no 172 31 106sb ) , 10273807 lv1 / r72 18.01.002sb.a assy blower , 10274024 lv1 / r72 172 12 016sb mtg of turet race ball suport, lock assy , 10274406 lv1 / r72 176 93 002sb mounting of racks in turret , 10274517 lv1 / r72 172 17 004 electro magnet karden shaft , 10274626 z6 / r72 misc gost 10450 78 5 01 016 washer ( 5.01.016 ) , 10274703 lv1 / r72 219 09 816 02 gasket ( to die wse nfp ) , 10274805 lv1 / r72 219 09 816 03 gasket , 10274872 lv1 / r72 219 09 816 06 gasket , 10275125 lv1 / r72 219 09 816 04 gasket , 10275143 lv1 / r72 219 09 816 05 gasket , 10275616 lv1 / r72 219 09 588 pusher , 10275634 lv1 / r72 219 09 590 union , 10275674 lv1 / r72 219 09 603 cover , 10275692 lv1 / r72 219 09 706 cap , 10275719 lv1 / r72 219 09 432 stop , 10276023 lv1 / r72 172 65 003sb 3 leverage , 10276064 lv1 / r72 172 62 054a lever left hand , 10276217 lv1 / r72 3020002715 gear ( drg no 175 36 064 a ) , 10276223 lv1 / r72 172 45 075 nut , 10276234 lv1 / r72 172 62 091 cam , steering right hand , 10276779 lv1 / r72 172 60 147 body , 10276867 lv1 / r72 176 02 038 arrester , 10277077 lv1 / r72 172 62 053a lever right hand , 10277413 lv1 / r72 2520012799 pump impeller ( drg no 172 47 040sb ) , 10277472 lv1 / r72 172 45 312 lever, coupling , 10277791 lv1 / r72 172 62 092 cam, steering left hand , 10278141 lv1 / r72 172 64 026sb rod , 10278671 lv1 / r72 2520012508 cover ( drg no 175 36 066 ) , 10278927 lv1 / r72 172 47 073 spring , 10278989 lv1 / r72 172 11 030sb cover , 10279103 lv1 / r72 2540009126 frame , 10279205 lv1 / r72 2590023938 rack ( drg no 172 91 296sb ) , 10279945 z6 / r72 5930 004686 switch box ( 2a 26cb 10 49 ) , 10279962 lv1 / r72 2510008785 race ring assy ( drg o 172 12 015sb ) , 10280380 lv1 / r72 175 33 185sb pipe branch , 10280422 lv1 / r72 172.47.238 puimp impeller , 10280503 lv1 / r72 172 62 030sb lever , 10281377 lv1 / r72 172.36.081sb valve , 10281407 lv1 / r72 172.36.067sb boiler preheater , 10282006 lv1 / r72 155.22.011 lock , 10282191 lv1 / r72 172 02 733 clamp , 10282226 lv1 / r72 155.22.010a end piece , 10282318 lv1 / r72 172.33.715 pipe union body , 10282577 lv1 / r72 434 71 123 1 plate , 10282601 lv1 / r72 434 71 126 1 plate , 10282883 lv1 / r72 155 38 389 pipe union , 10282889 lv1 / r72 155 38 400 washer , 10282918 lv1 / r72 457 07 207 spring , 10282993 lv1 / r72 4710003271 pipe ( drg no 172 36 056sb ) , 10283291 lv1 / r72 3040023225 spindle ( drg no 432 70 642 ) , 10283313 lv1 / r72 3040023384 fork ( drg no 172 61 016sb ) , 10283362 lv1 / r72 3040023081 rod clutch ( drg no 172 63 072sb ) , 10287961 lv1 / r72 219 09sb 704 bushing , 10287968 lv1 / r72 219 09 591 seal , 10288304 lv1 / r72 sb 3335 14 2 subassy swivel nipple / rotatg elbow w / spg , 10290571 lv1 / r72 gost 792 67 ( rms 1036 ) wire ko 1.4 , 10291354 lv1 / r72 175 71 005sb fan , 10291374 lv1 / r72 172 23 004sb hand wheel , 10292620 lv1 / r72 176 70 041 gasket , 10292627 lv1 / r72 176 70 010 plate , 10292764 lv1 / r72 5306 056903 bolt 3m6 6gx30.66.016 , 10293253 lv1 / r72 418h 000tu electro magnet ( to die wse nfp ) , 10294948 lv1 / r72 175 60 042 housing , 10295111 lv1 / r72 175 52 041 block , 10299387 k9 / t72 / nbc 172 87 122sb lever , 10299395 k9 / t72 / nbc 172 87 087sb 1 ( r / oh 1162 ) bracket , 10299405 k9 / t72 / nbc 172 87 217 / 2 bracket , 10299483 k9 / t72 / nbc 4310003693 booster ( drg no 175 87 056cb 1 ) , 10299532 k9 / t72 / nbc 175 87 185 ( r / oh 1166 ) clamp , 10299535 k9 / t72 / nbc 175 87 077sb / 2 booster , 10299550 k9 / t72 / nbc 2530017927 buffer ( drg no 166 26 046 1 ) , 10491570 x2 / r72 misc geo.364.140ty ( 4 pin ) plug 2 pmg 22b 4 sh3 e2b , 10491597 x2 / r72 misc 5920 913615 fuse link elecl glass cartridge 5amps , 10491599 x2 / r72 misc 5920 913610 fuse link elecl glass cartridge 2amps , 10491723 x2 / r72 misc 2pmgd 3620 w6e2b or 2pmgd36b20sh6a2 connector , 10491724 x2 / r72 misc 2pmgd 3332w5e2 or 2pmgd 33 b32sh5b2 connector , 10491729 x5 / r72 gost 16214 86 tape light blue 15x0.20mm , 10491815 z1 / r72 misc d231a diode231a , 10491878 z1 / r72 misc tadiran 4033 00807 00 bnc to bnc adapter , 10491884 z1 / r72 misc rso 452 049ty ( res 10 ) relay res 10 type 529 031 03.06 , 10491886 z1 / r72 misc rso 452 049ty relay res 10 type 529 031 03 , 10491994 z6 / r72 5995 003134 cable assy special purpose electrical , 10492059 z6 / r72 2a46 sb 10 19 ( roh 1223 ) connector unit , 10492066 z6 / r72 172 77 014sb bracket , 10492081 z1 / r72 misc 0ab 523 512 relay 83123 ( drg no 0a6 523 512 ) , 10492132 z6 / r72 rus bs8 652 090 pipe union ( bk8 652 090 ) , 10492167 z6 / r72 misc gost 5916 70 nut m3 a5.026 , 10510393 lv1 / r72 5930 028937 switch p2t 17 or p2t 17 t ( vto 360 002tu , 10510775 lv1 / r72 gost 7808 70 / ( m8x1 ) bolt m8x1 6gx75.66.016 , 10510863 lv1 / r72 gost 397 79 ( oh 220 ) split , 10511758 n1 / r72 1015 002947 bush ( drg no 172 28 025 ) , 10511765 n1 / r72 1015 002950 rod ( drg no 172 28 036 1 ) , 10511781 n1 / r72 1015 002868 lever ( for breech mech ) ( 2a26 02 60 ) , 10511853 n1 / r72 1015 002829 clamp ( 2a26 sb 06 6sb ) , 10511937 n1 / r72 1015 003038 axle ( drg no 172 27 167 ) , 10512178 n1 / r72 5365 008976 shim ( mounting ) ( 434 20 044 ) , 10512327 n1 / r72 5365 004046 shim ( 165 34 097 ) , 10512346 n1 / r72 5365 004057 plug ( for cartridge base disposal mech ) , 10512388 n1 / r72 5325 008820 slider ( hand wheel assy ) ( 2a46 21 46 ) , 10512462 n1 / r72 3040 023220 shaft ( rotary conveyer manual drive ) , 10512529 n1 / r72 1015 004467 detent ( cell lifting mech ) ( 172 28 167 ) , 10512534 n1 / r72 1615 001641 stop ( elevation mechanism ) ( 2a46 21 60 ) , 10512547 n1 / r72 3020 002593 roller ( drg no 172 28 178 1 ) , 10512598 n1 / r72 5310 021490 washer ( 8.01.02.12 ) ( guard ) , 10512611 n1 / r72 5315 003977 pin lock ( for mounting ) , 10512691 n1 / r72 3120 001654 bush ( ordnance ) ( 2a26 02 311 ) , 10512735 n1 / r72 3120 004365 bushing ( for cell lifting mech ) , 10512766 n1 / r72 4030 001071 lug ( drg no 2a26 02 266 ) , 10512768 n1 / r72 4010 000776 wire rope ( mounting ) ( 172 20 050 ) , 10512870 n1 / r72 5305 016441 screw bm6 8gx16.66.c.029 ( gost 1491 80 ) , 10512873 n1 / r72 5305 016442 screw bm12 8gx25.66.c.06 ( brechblokassy ) , 10512928 n1 / r72 1015 004276 frame ( cartridge base disposal mech ) , 10512954 n1 / r72 1015 002913 installation of system ( 172 20 sb 6sb ) , 10513072 n1 / r72 1015 002958 strip right hand ( for cell lifting mech ) , 10513127 n1 / r72 1015 002886 cover ( cradle ) ( 2a20 09 37 ) , 10513172 n1 / r72 5315 005748 pin for barrel , 10513208 n1 / r72 5315 005662 split pin 4x50.006 cradle , 10513259 n1 / r72 5315 008836 spindle ( for cell lifting mech ) , 10513261 n1 / r72 5315 009338 evacubator chamber casing ( for barrel ) , 10513269 n1 / r72 5315 049974 post ( shelf assy ) ( 2a26 10 292 ) , 10513313 n1 / r72 5306 011446 bolt ( for barrel assy ) , 10513368 n1 / r72 5307 003355 screw ( elevation mech ) , 10514046 n1 / r72 9515 013955 thrust plate ( elevating mech ) ( 2a20 21 53 ) , 10514113 n1 / r72 5330 012491 gasket ( elevation mech ) ( a 52321 15 ) , 10514117 n1 / r72 5330 383675 gasket ( elevation mech ) ( 2a46 21 87 ) , 10514139 n1 / r72 5330 383674 strip ( elevation mech ) ( 2a20 21 226 ) , 10514333 n1 / r72 5999 004643 breech ring contact assy ( 2a26sb 02 22sb , 10514418 n1 / r72 5365 183737 distance bush ( rotry convyr manual drive , 10514458 n1 / r72 1015 003448 cap ( 8 x 15 ) , 10514482 n1 / r72 1015 004172 lock housing ( rotary conveyer ) , 10514496 n1 / r72 1015 003954 mounting of conveyor drive assy , 10514518 n1 / r72 1015 003889 casing ( guard assy ) , 10514546 n1 / r72 5340 176839 bolt ( mounting elevating mech ) , 10514589 n1 / r72 1015 003069 cover ( drg no 172 26 32 2b ) , 10514670 n1 / r72 1015 004045 bracket ( cartridge base disposal mech ) , 10537571 k9 / t72 / nbc 166 26 047 1 ( ms 1190 ) axle , 10542346 y3 / r72 5970 910139 sleving elec pvc 5mm 1d 0 5mm thic white , 10542437 z1 / r72 misc ojo 460 107 tu resistor omlt 2 390 + / 5% r1 & r2 , 10542443 z6 / r72 misc 5dm 670 135 inductor ( misc 5bd 670 019 ) , 10542445 z6 / r72 misc bc8 684 073 gasket ( misc bc8 684 088 ) , 10542448 c2 / r72 172 22 057 ( oh ) pin ( 172 22 030 ) , 10542454 n1 / r72 5315 053103 key 14x9x36 ( elevation mech ) , 10544382 lv1 / r72 3110 000132 bearing ball journal single row , 10544728 n1 / r72 1015 002941 spindle ( drg no 172 28 014 ) , 10544769 n1 / r72 1015 003096#1 lock ( for rotary conveyer ) , 10544899 z1 / r72 5961 926206#1 transistor npn or 2n1613 , 10544931 z1 / r72 misc 2051 90777 00#1 antenna tie down kit , 10545129 z6 / r72 172 74 172 1 casing , 10545132 z6 / r72 172 77 019sb case assembly , 10545135 z6 / r72 3120 105470 bushing sleeve ( 172 74 329 3 ) , 10545136 z6 / r72 4030 003735 hook ( 172 74 322 ) , 10545144 z6 / r72 4720 014856 hole assy ( bs6 450 087 ) , 10545272 n1 / r72 1190 000067#1 lower housing ( rotary conveyer ) , 10545273 n1 / r72 1095 003167 mounting of flange , 10545364 n1 / r72 2520 012823 door cover drive mtg , 10545373 n1 / r72 1680 073358 casing ( cartridge base disposal mech ) , 10545431 n1 / r72 1015 002840#1 frame ( jacket assy ) ( 2a26 06 19 ) , 10545488 n1 / r72 2540 002789#1 shaft ( mtg of rotary conveyer ) , 10545490 n1 / r72 2590 000969#1 lock ( barrel assy ) ( a 71237 7sb ) , 10545538 n1 / r72 3110 003798#1 collar ring ( drg no 2a26 08 23 ) , 10545813 n1 / r72 1015 002988 spindle ( 6x3x56 ) ( cell lifting mech ) , 10545947 n1 / r72 5305 013334#1 screw ( for breech mech ) ( 2a20 02 37 ) , 10546015 n1 / r72 5305 009910 screw m4x15 ( for recoil brake ) , 10546113 n1 / r72 3940 000001#1 gripper ( cartridge base disposal mech ) , 10546138 n1 / r72 3120 001551 bearing ( 4074116 ) ( gost 4657 71 ) , 10546183 z6 / r72 5930 004685 switch assy ( 2a 46sb 21 5 ) , 10546184 z6 / r72 5915 004626#1 filter radio frequncy intrfernce ( filtr 5 , 10546208 n1 / r72 5306 007305#1 bolt ( for cartridge base disposal mech ) , 10546440 n1 / r72 5315 000547#1 cotter pin 2 x 25.06 , 10546456 z6 / r72 5360 007830#1 spg helical compresion ( 3800 732 601 04a ) , 10546457 z6 / r72 5340 72 023 7645 clamp loop ( 172 74 355 ) , 10546499 z6 / r72 misc gost 6402 70 washer 365t06 , 10546566 z6 / r72 misc 4320 012 001 40 ic op amp op 07 , 10546611 z6 / r72 misc bk8 683 000 gasket , 10546621 z7 / r72 434 84 001 sb 2 bracket , 10546642 n1 / r72 5330 014994#1 ring ( automatic loadg gear sys ) 175 18 030 , 10546839 n1 / r72 5340 008524 handle , 10560604 lv1 / r72 172.36.099 gasket , 10560605 lv1 / r72 172.36.100 gasket , 10561372 lv1 / r72 172.91.123sb clamp assy , 10561378 lv1 / r72 172.91.154sb rack , 10562245 lv1 / r72 54.26.560 clip , 10564798 lv1 / r72 520.07.003.04 washer , 10584989 z1 / r72 pco 452 020 relay polarised non hermatic , 10585070 z1 / r72 pco 365 003ty relay socket , 10585081 z6 / r72 5340 20000296 or 490900100175 cord lacing nylon brd 1mm vide 0.05mm to , 10585084 z6 / r72 pp28 001 or 273000850138 toothed gear , 10585086 z6 / r72 5k8 041 003 or 350073130174 cover al. gr. casting ( g.s.d ) , 10585090 y3 / r72 std wire ptfe 600v19 / 0.13 od1.2w , 10585095 x2 / r72 plug2pmd27kp319g581 con ciru thd pl st sc female 2rmd 27 / 19 / , 10585099 z6 / r72 bc6 170 066 or 273000790192 cover drilled , 10585100 z6 / r72 8am 760 102 or 273002340155 insulating plate , 10585109 z1 / r72 jan 1n 1206a diode rect schottky jan 1n1206a , 10585110 z6 / r72 4e4 77 034 or 273002880154 band , 10585116 z6 / r72 bk8 253 000 or 273000390164 roller , 10585117 z6 / r72 bc6 130 008cb or 175000504076 bracket assy , 10585118 z6 / r72 bk 041 948 01 or 275100090188 cover machined / drilled , 10585121 z6 / r72 oct3 408 70 or 273003460117 shaft clamp , 10585122 z6 / r72 k0 0, 5 or 273001850984 wire galvnised , 10585123 z6 / r72 k0 1, 2 or 273001851081 wire galvnised , 10585125 z1 / r72 bq8 634 009 relay base , 10585126 z1 / r72 pec 9 00 01 relay nonher 22v dpdt , 10585128 z1 / r72 res 9 09 01 relay nonher 22v dpdt , 10585130 z1 / r72 5961 04284 semi conductor device diode type jan 1n , 10585131 z1 / r72 op400hs ic lin opamp quad op400hs sol16 , 10585132 z6 / r72 adxl103ce or 433775400174 ic lin sf lin ckt single axis accelerome , 10585134 z6 / r72 bk7 816 363 or 273000700176 board drilled / marked , 10585135 z6 / r72 8am 024 021 or 273002370128 panel , 10585136 z6 / r72 8at 572 093 or 475873120135 lug , 10585137 z6 / r72 8at 572 094 or 475873130126 lug , 10585138 z6 / r72 8am 760 067 or 273002380119 panel , 10585141 z6 / r72 bk9 280 150 or 273004010107 boss , 10585142 z6 / r72 bk7 060 049 or 275100140143 impeller drilled / machined , 10585143 z6 / r72 026 01 01 or 273003070177 housing , 10585144 z6 / r72 0219 03 03a or 273003110141 board , 10585145 z6 / r72 026 05 08 or 273003120132 stop , 10585146 z6 / r72 u026 05 09 or 273003120229 stop , 10585147 z6 / r72 019 43 85a or 273003130123 stop nut , 10585148 z6 / r72 019 45 87 or 273003180175 return spring , 10585149 z6 / r72 035 c89 21 or 36007350114 coil for : mer , 10585150 z6 / r72 bc8 634 081 or 273000040188 cap , 10585151 z6 / r72 pp28 019 contact , 10585153 z6 / r72 bk9 276 002 or 273000150186 partition , 10585154 z6 / r72 bk8 613 846 or 273000160177 side plate 1 , 10585155 z6 / r72 bk8 613 847 or 273000170168 side plate 2 , 10585156 z6 / r72 bk8 010 354 or 273000270175 frame , 10585157 z6 / r72 8am 732 005 or 360073100152 coil for : mer , 10585158 z6 / r72 bc8 054 111 or 273000070161 cover machined , 10585159 z6 / r72 bc8 326 893 or 273000330121 pipe , 10585160 z6 / r72 bc8 634 034 or 273000110125 cap bottom , 10585171 z6 / r72 bk8 021 189 or 350073140165 body alu. gr. cast ( k2 box ) , 10585174 x2 / r72 h0 774 500 fuse holder , 10585178 z6 / r72 8am 064 055 or 273002420180 insulating plate , 10585179 z6 / r72 8am 760 078 or 273002430171 insulating liner , 10585180 z6 / r72 5am 060 078 or 360073070179 panel , 10585182 z6 / r72 5am 040 006 or 273002500108 bracket , 10585183 z6 / r72 8 ac 732 009 or 360073090161 coil frame , 10585184 z6 / r72 432 24 018 2 lower idle gear , 10585185 z6 / r72 5k6 668 004 or 175000508538 rotor stack assy , 10585186 z6 / r72 bc8 319 067 or 275100100179 axle , 10585188 z1 / r72 035 c84 12 instrument transfor :mer , 10585189 z6 / r72 172 77 079 a or 273001660185 shield , 10585190 z6 / r72 172 76 080sb bracket , 10585191 z6 / r72 175 77 085 1 or 273003360110 apron , 10585194 z6 / r72 8am 1064 031 or 273002440162 terminal plate , 10585196 z6 / r72 026 02 03 or 273003090159 inner diaphragm , 10585197 z6 / r72 026 04 05a or 273003100150 outer diaphragm , 10585198 x5 / r72 6040 004106 lamp incand 28.0v 0.04a , 10585201 z6 / r72 ba8 040 013 or 273001390137 cover , 10585203 z6 / r72 tpp 213 40 400 or 495073070148 transfor :mer , 10585204 z6 / r72 175 24 089 or 273002980161 plate , 10585205 z6 / r72 432 24 050 1 or 73002990152 upper clamp , 10585206 z6 / r72 432 24 051 or 273003000143 lower clamp , 10585207 z6 / r72 432 24 052 or 273003010134 front clamp , 10585208 z6 / r72 bk7 725 118 plate , 10585209 z6 / r72 bk 8 652 417 pipe connector , 10585210 z6 / r72 bk 8 652 054 pipe connector , 10585211 z6 / r72 5?m 112 045 brush , 10585212 z6 / r72 wp28?43w5 plug , 10585213 z6 / r72 ct 13463 78 washer , 10585214 z6 / r72 rsg 10m 50sb contact plate , 10585215 z6 / r72 rsg 10m 20sb movable contact , 10585216 z6 / r72 rsg 10m 100 bolt , 10585217 z6 / r72 ch1 2771f bolt , 10585218 z6 / r72 rsg 10m 030 bolt , 10585219 z6 / r72 rsg 10m 0576 bolt , 10585220 z6 / r72 0653 51 1516 bolt , 10585221 z6 / r72 0653 f1 0103 spring washer , 10585222 z6 / r72 ch1 1084b1 bolt , 10585223 z6 / r72 ch5 1932ax washer , 10585224 z6 / r72 0653 51 063 bolt , 10585225 z6 / r72 rsg 10m 011 washer , 10585226 z6 / r72 bk4 458 013 shock absorber , 10585227 z6 / r72 172 27 005 band , 10585228 z6 / r72 475775191263 ring terminal ( insulated ) , 10585229 z6 / r72 475775192718 ring terminal ( insulated ) , 10585230 z6 / r72 485000414190 wire cop anl sil 0.80 4% , 10585231 z6 / r72 475775191651 ring terminal ( insulated ) , 10585232 z6 / r72 475775190584 ring terminal ( insulated ) , 10585233 z6 / r72 475775190681 ring terminal ( insulated ) , 10585234 z6 / r72 475775194561 ring terminal ( insulated ) , 10585235 y3 / r72 458900300262 wire ptfe 1000v 19 / 0.16 od 1.6w , 10585236 y3 / r72 485900300359 wire ptfe 1000v 19 / 0.20 od 1.8w , 10585237 y3 / r72 485900300456 wire ptfe 1000v 19 / 0.25 od 2.1w , 10585238 x3 / r72 545500400493 tape acetate cloth black 12.7 , 10585239 y3 / r72 489400207993 sleeve si elastr extd 4.0 br , 10585240 z6 / r72 304500641002 circlip external sst 22 , 10585241 z6 / r72 475701300543 terminal insul lug crp 22 18 stud sz 6 , 10585242 y3 / r72 485900301232 wire ptfe 1000v19 / 0.16 od1.6bk , 10585243 z6 / r72 360075220184 box moulded , 10585244 x2 / r72 568001400380 silicone cmpd potting / encap , 10585246 x2 / r72 568001400186 silicone encap cmpd pouring / potg rtv11 , 10585247 x2 / r72 568001400283 catalyst silicone pourng / potting , 10585248 z6 / r72 490900100272 cord lacing nylon brd 2mm , 10585249 y3 / r72 485900200449 wire ptfe 600v19 / 0.16 od1.4w , 10585250 z6 / r72 475875280131 end terminal , 10585251 z6 / r72 273002650167 plate , 10585252 z6 / r72 511600102226 copper beryl strip tb00 0.20x100 , 10585253 z6 / r72 490900700314 clamp nylon ca sprt 5.6 bk , 10585254 z6 / r72 490900700411 clamp nylon ca sprt 6.4 bk , 10585255 z6 / r72 175000942613 cable for : m t 72 block relay , 10585256 z6 / r72 475775191845 ring terminal ( insulated ) , 10585257 z6 / r72 475701301416 terminal insu lug crp 12 10 stud sz 1 / 4 , 10585258 z1 / r72 476000800265 semicond mtg bush 11 , 10585259 z1 / r72 406000205125 cap fxd alel 10uf±20% 50v , 10585260 z6 / r72 476011390143 mounting base ( 8 p.n.ic ) , 10585261 z6 / r72 275001940156 base plate , 10585262 z6 / r72 275000060102 plate , 10585263 z6 / r72 275101880129 housing machined ( l a t ) , 10585264 z6 / r72 490900700120 clamp nylon ca sprt 3.2 bk , 10585265 z6 / r72 551000321445 presspaper strip 0.5x30 , 10585266 x2 / r72 545500400396 tape acetate cloth white 12.7 , 10585267 z6 / r72 375610420181 insulating bush ceramic , 10585268 z6 / r72 360175890761 nylon spacer , 10585269 z6 / r72 273001310112 panel drilled & marked , 10585270 z1 / r72 423273010160 rectifier mda 990 1 , 10585271 z6 / r72 304900119012 eyelet flat flange 2x4 , 10585272 z6 / r72 360175530115 label , 10585273 z6 / r72 273000280166 frame ( main ) , 10585274 z6 / r72 276719640115 coupling dia 30 , 10585275 z6 / r72 176700179301 fitting for : cob assy 2 ( traverse ) , 10585276 z6 / r72 276719700158 swivel elbow , 10585277 z6 / r72 545000427670 glass epoxy sheet 3.2 , 10585278 z6 / r72 516700200139 aluminium casting alloys , 10585279 z6 / r72 275801440152 p.b. drawing trav. & elev. control , 10585280 z1 / r72 275700340156 p.c. board capacitor , 10585281 z6 / r72 475800900337 eh noninsul ter pcb1.6mm type 2 , 10585282 z6 / r72 275700350147 p.c. board capacitor , 10585283 z6 / r72 511600105039 copper beryl strip tb00 0.50x10 , 10585284 z6 / r72 304900130555 eyelet flat flange 3x7 , 10585287 z6 / r72 476001200196 mounting resistor capacitor pitch 2.5 , 10585289 z6 / r72 475701301319 terminal insul lug crp 12 10 stud sz 8 , 10585291 y3 / r72 589400208866 sleeve si elastr extd 4.0 pk , 10585292 z6 / r72 304900130264 eyelet flat flange 3x4 , 10585293 z6 / r72 475400300231 cap assymbly red , 10585295 z6 / r72 302400147421 insert thread :ed aisi 304 m6x6 , 10586546 z1 / r72 tke52pb1 relay , 10586547 x2 / r72 misc pp14 10lb con rect m10 / 5.0a , 10586548 x2 / r72 misc teo 364 140ty plug 2 pmt 225 4w3e25 , 10586799 z6 / r72 172 77 087 or 273003420153 case , 10589375 y3 / r72 misc gost 19034 ( 4x0.6mm ) pvc sleeve 4 mm , 10589487 y3 / r72 misc gost 19034 ( 6x0.6mm ) pvc sleeve 6 mm , 10592077 n1 / r72 1015 003425 axle ( drg no 2a26 10 2 ) , 10592877 lv1 / r72 432 23 053 seal, oil , 10592878 lv1 / r72 434 23 032 1 rim , 10592879 lv1 / r72 434 23 062 plug , 10597421 lv1 / r72 172 65 077 support , 10597447 lv1 / r72 184 71 043sb bracket , 10597448 lv1 / r72 172 70 525 lug , 10597449 lv1 / r72 172 71 012sb 10 distribution panel rh assy , 10597450 lv1 / r72 172 70 523 lug , 10597467 lv1 / r72 172 91 017sb a clamp assy , 10597468 lv1 / r72 175 91 172 gasket , 10597469 lv1 / r72 176 91 012sb guard , 10597470 lv1 / r72 172 33 226sb rear rack tank , 10597471 lv1 / r72 175 02 496 flange , 10597472 lv1 / r72 175 37 009 body , 10597473 lv1 / r72 175 47 045sb cup , 10599012 n1 / r72 175 18 064 1 rh plate for :m , 10599013 n1 / r72 176 18 065 1a strap , 10599014 n1 / r72 175 18 006a strap , 10599015 n1 / r72 175 18 007a strap , 10599016 n1 / r72 172 18 021sb 9 turn table , 10599017 lv1 / r72 172 28 88sb 3 clm m1k , 10599018 lv1 / r72 175 085sb assy seat mech , 10599019 lv1 / r72 172 15 207b liner , 10599020 lv1 / r72 175 15 048b liner , 10224708 v5 / r90 rus 187 94 004 sb 2 01 bh elevation drive assy , 10227365 z6 / r90 5306720060619 bolt, machine , 10227878 y3 / r90 5970 000190 insulaton sleeving elect pvc 3mmx4mm od , 10229171 z6 / r90 misc t 90s gost 1491 80m4 6g 12 58 insulaton sleeving elect pvc 3mmx4mm od , 10230982 n1 / r90 n1 / 5306 056996 bolt 3m10 6gx25.66.016 gost 7808 70 , 10231058 z6 / r90 misc bc8 634 111 cap , 10232668 n1 / r90 2a26 02 317 upper contact ( breech mech ) , 10232682 z6 / r90 misc t 90s bs6 644 160 cable no 6 st , 10233670 z6 / r90 misc t 90s r15m 3s 260 printed circuit board , 10233854 n1 / r90 gost 5918 73 ( arhoh 146 ) nut m6 7h.5.019 , 10234046 n1 / r90 1005 560737 semi automatic gear cam , 10235115 z1 / r90 misc bk2 089 089 unit bv 34 , 10235913 n1 / r90 188 18 004 sb 17 sb deck , 10237142 v5 / r90 rus 188 94 017sb 1 cradle assy , 10237521 n1 / r90 rus / t90 / gost 792 67 wire ko 2 , 10238073 c2 / r90 188 94 116 nut , 10238860 z6 / r90 rus t 72 763 65tu micro switch a 812k micro kib9443 22 ( 47 ) , 10240314 z6 / r90 misc t 90s bl4 864 309 wire bundle of wind sensor dvye , 10243445 z7 / r90 rus al2 378 006 01 ranging sight 1g 46 , 10256743 y3 / r90 misc gost 16214 86 15x0.2 pvc tape 15x0.2 , 10256856 lv1 / r90 gost 6958 78 / washer c 3.01.016 , 10491661 z7 / r90 rus ascye5 103 012 correction block , 10491872 z1 / r90 misc 2020 09567 10 cx 5607 ( 0.45m ) inter com cable , 10514287 n1 / r90 wire ko 1.2 gost 792 67 wire ko 1, 2 ( cell lifting mechanism ) , 10514357 n1 / r90 1015 012757 recuperator assy ( 2a46m sb 07sb ) , 10544566 z7 / r90 1290 720465276#1 cable no 62 ( drg no bel 175000541518 ) , 10558448 z7 / r90 rus yu 43 56 472# control unit psu vp 30 , 10560222 z7 / rus 155.36.16sb wiper assy , 10560327 n1 172.18.081sb guard , 10560368 lv1 / r90 172.23.006sb 1 azimuthindicator , 10560369 lv1 / r90 172.23.007sb 1 body , 10560379 lv1 / r90 172.23.029sb neck , 10561276 z6 / misc 172.77.163 02 gasket , 10561758 n1 t 90 / 28 / clr / cqa ( ava ) / kit no / 030 / 2016 clr kit for cell lifting mechanism 188.2 , 10562295 z7 / rus 184.81.032sb scraper , 10562296 z7 / rus 184.81.041sb stop , 10562376 z7 / rus 187.81.008sb.1 screw , 10562407 z7 / rus 187.81.020sb wire , 10562499 z7 / rus 60.03.009 screw , 10562502 z7 / rus 60.03.085 screw adjusting , 10562504 z7 / rus 60.07.006 washer , 10562525 z7 / rus 60.07.083 washer , 10562531 z7 / rus 60.07.980 washer bent , 10562551 z7 / rus 188.21.006 spring , 10562568 z7 / rus 188.21.014sb flange , 10562611 z7 / rus 188.21.046.01 bolt , 10562656 z7 / rus 188.21.176 holder , 10562937 z6 / misc 188.74.020sb 2 cable bundle no.24 , 10563034 z7 / rus 188.81.005sb lever , 10563036 z7 / rus 188.81.006 shackle , 10563068 z7 / rus 188.81.023sb illuminator , 10563351 c2 / r90 188.94.111 pin , 10563411 z7 / rus 190.81.072 plug , 10563639 n1 2#46#.02.98 lever , 10564436 z7 / rus 434.84.047 stoper , 10564491 c2 / r90 434.94.169 cover , 10564583 z7 / rus 447#.21.037 shaft , 10564964 z7 / rus 520.15.001.10 packing ring , 10569440 z7 / rus g#s#9650 80 axle 6 5d11x16.#.38xs.2.35, 5...45, 5.tsbx , 10570572 k9 / t90s / nbc 172.80.004 1a liner , 10570576 z7 / rus kvd / nnk / clr / gost7808 70 / 1745.38 bolt 3#8 6g#40.88.38#s.016 , 10570584 z7 / rus kvd / nnk / clr / gost9650 80 / 1745.51 axle 6 6d11#18.40.ts6.## , 10570587 z7 / rus 188.81.055 screw setting , 10578932 n1 1015012724 label with pin ( 2a46m.sb10.13 ) , 10578980 n1 5310242307 protective washer ( 2a31.07.14 ) , 10579001 n1 5325008072 ring retaining ( 2a46m.01.20 ) , 10579008 n1 5340176854 bracket ( 172.28.030.1a ) , 10579048 z7 / rus 188.77.095sb bracket , 10579049 z7 / rus 188.77.098sb 1 cable bundle sanoet , 10579050 z7 / rus 188.77.103sb bracket , 10579179 z7 / rus gost13463 77 washer 10.01.016 , 10579394 n1 gost7796 70 bolt 3m8 6gx20.66.06 , 10579396 z6 / r90 gost7796 70 bolt 3m8x1.6gx45.88.38xc.016 , 10579397 z7 / rus gost7796 70 bolt m10 6gx16.46.016 , 10579404 z6 / r90 gost7796 70 bolt m8 6gx40.46.016 , 10579441 z7 / rus gost7808 70 bolt 3m8.6gx30.66.016 , 10586391 z7 / rus gost 6402 70 ( 6 65g 029 ) washer 6 65g 029 , 10586404 z6 / r90 gost 7808 70 ( 55.66.016 ) bolt m10 6gx55.66.016 , 10586446 z7 / rus gost 1491 80 ( 6gx10.48 ) screw bm3 6gx10.48.026 , 10586455 z7 / rus gost 7808 70 ( 6gx50.66 ) bolt m12 6gx50.66.016 , 10586464 z7 / rus gost 17475 80 ( 6gx30.46.016 ) screw m6 6gx30.46.016 , 10586468 z7 / rus gost 7798 70 ( 35.46.016 ) bolt m6 6gx35.46.016 , 10586526 n1 / r90 gost11371 78 ( 01.10.0215 ) washer c.6.01.10.0215 , 10264676 lv3 / r72 k12019t gasket , 10511751 lv3 / r72 350 26 stud m6x21 , 10512049 lv3 / r72 k 12007 securing ring...

Tata Memorial Centre - Maharashtra

31977795 supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos. along with required turnkey works. , cat ( a ) supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos along with required turnkey works. , supply, installation, testing and commissioning of linear accelerator ring gantry at actrec, kharghar, maharashtra as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at tmh, mumbai, maharashtraas per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at bbci, guwahati, assam as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at civil hospital, shillong, meghalaya as per tendered technical specifications , turnkey works at actrec , civil modification & interior works , architectural & structural audit & design consultancy: appointment of reputed, govt registered architectural, structural designer having mre than 10 years of experiencedto render interior & structural design consultancy for improvemetn and strucutral rehabilitation work as per aerbs recommendation and interior works matching the existing design, considering the following scope of work. study of available structural audit reports of the referred bunker study of the existing building drawings, structural system and history of repairs visual inspection the bunkers externally and internally tapping exercise with the use of hammer assessment of all structural elements ( slabs, beams, columns, rc walls ) conducting necessary non destructive tests on concrete of existing bunkers ultra sonic pulse velocity 15 nos. points / bunker re bound hammer min 15 nos. points / bunker conducting necessary partial destructive tests on concrete of existing bunkers core cut 1 no. points / bunker preparation separate structural audit reports certifying feasibility of proposedstructural changes at the existing bunker ( aerb drawings ) analysis & design of structural elements for accommodating proposed structural changes at the existing bunker ( aerb drawings ) considering the items mentioned in the boq. preparing ga / schematic structural drawings for proposed revisions getting client’s approval on complete set of ga / schematic drawings sharing design, analysis and ga / schematic drawings to clint appointed structural designer for vetting and incorporating suggested recomendationa and implementing the same before issuing the gfc drawings. preparing working drawings ( structural ) for proposed revisions nominal changes to accommodate in the drawing, if any, as per client’s requirement visiting site to inspect the execution work. total visits 3 nos. issuing stability certificate only after completion of work to our full satisfaction. , preparatory civil , preparation of existing rcc wall or brick wall surface, by scrapping, existing finish / paint cleaning the exposed concrete surface to remove any fungus, loosely particles, scales, by a stiff wire brush, clean by water wash the entire surface, exposed the damaged concrete surface with the help of small chisel and hammer, including collecting, stacking the debris at the site. , carefully removing or chiseling, existing plaster of thickness up to 20 mm from the damaged surface with the help of small chisel and hammer weighing not more than 5 pound, includingcollecting, stacking & carting away the debris from the site wherever required as directed by site incharge , removing existing flooring & skirting tiles, along with backing and bedding mortar, clean the surface, lifting & shifting debris to ground floor & carting away the same out of premises etc. complete. , breaking & removingexisting rcc wall by mechanical cutter without disturbing the adjacent structure, or any other concretemembers including cutting ofreinforcement bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. ( 30 mm thk ) , demolishing the existing brick wall along with plaster bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. , brick wall 230 mm thick , brick wall 115 mm thick , carefully excavating in any kind of soil, in existing building in or out sides, including necessary shoring / propping if required and including carting away the debris including re making the surface in good as same as existing as directed. including dewatering and necessary back filling complete , dismantling of existing wooden / aluminium doors and handing over to the client as directed by pm. , labor charges for shifting the furniture remove all the cupboards and shift the same as directed to facilitate the work. , dismantling existing terrace water proofing including aap membrane, cleaning the roof top free from dust and dirt with mechanical wire brush make it receive new concrete, shifing of debries from terrace to ground and carting away out of actrec campus complete as directed and instructed. , construction civil , leveling and filling of earth below foundation and plinth level with quarry dust mixed with 5% cement ( by volume ) for the depth of 150 mm. after initial fill of 75 mm thick, pour water with required compacting, watering make the sub soil in good condition, pour water to dampen the dry mix enough to cake form. similarly fill second layer of 75 mm. pour water with required compacting after each stage of layer to make the mix damp enough to become solid form , providing and laying p.c.c. m15 ( 1:2:4 ) concrete in foundation as leveling course 150 mm thick including necessary form work, batching, mixing, placing, consolidating etc. complete including wet curing for specified time period. , supplying, providing and placing in position rmc m25 reinforced cement concrete with 20mm downgraded aggregates for walls of accelerator and maze rooms of thickness ranging from 300mm to 600 mm at all levels including vibrating, curing, providing construction joints, leaving cut outs / pockets for placing of inserts / embedment, etc., complete, including cost of providing steel form work with plywood lining for all shapes ( including scaffolding, centering, etc. ) , but excluding the cost of providing reinforcement all as per specifications.include precautions to control heat of hydration and obtaining a homogeneous compact concrete. all exposed concrete surface to be of form finish complete as directed and instructed. , for foundations , for rcc shielding , for terrace shieling , providing and fixing high density ( 7.75gm / cc ) steel plate to the existing concrete surface using holdfast and hot press technique. also, the footing required to carry weight of steel plate would be included as per approved design by the consultant. , supply &fabricating and fixing reinforcement for rcc work with high yield strength ribbed cold twisted tor steel of variousdiametersand all lengths of grade fe 415 / fe 500 conforming to bis specification including cutting, bending, fabricating, welding, wastage and placing in position according to drawings and binding the reinforcement with the use of 16 gauge galvanized binding wire of double fold and providing precast cement cover blocks for main reinforcements to ensure specified cover according to relevant is code.the measurements will be in accordance with is code 1200. , supplying, drilling / cleaning hole and injecting chemical laced heavy duty stainless steel anchor fasteners widely used in strucutral reahabilitation works to support re bars and strenth enough to support additional concrete throug mechnical drilling into exisitng concrete surface. the application to be designed separately for rebars as simply supported, moment or splice connection as per indian or european standard or relevant tested and accepted rebar guidelines. rebars. of 20 mm dia 200 300mm depth. the appointed strucutral designer should submit the detailed design analysis adopted, complete as directed and instructed. , providing and doing brick work with locally available good bricks of class designation 50, in required thickness of walls, in cm 1: 4, including adding polymer admixtureat 500ml per bag of cement, racking the joints, cleaning, carting away the wastages and curing , for 230 mm thick , for 115 mm thick , providign & constructing solid cement concrete block of m 10 grade of required thickness in cm 1:6 with scafolding, labour work at all heights and levels including wastage, scafolding etc omplete as directed and instructed. , providing and doing pressure groiuting with waterproofing compound or structural reapiring compund as per manufacturers specfication as directed by the structral consultant, withinsertion of pvc nozzles with drilling holes at regulaer intervals on exisit g rcc walls, beams, roof slabs etc complete as directed and instructed. ( cosnidered for exsitng rcc walls which are developed cracks. ) , providing & applying plaster at an average thickness of 12 to 15 mm in exact line & level in the proportion of 1 : 4 cement and sand mortar by manual mixing, with addition of waterproofing chemical @ 150 ml and harbourite 12 mm fine fibrillated 100% virgin polypropylene fibers @ 150 gm per bag of cement including curing for at least 7 days, carting away a debris, cleaning ( note: waterproof plaster considered in server room only ) , filling sunken portion of roof with brick bat mixed with cm 1:6 and complete as directed and instructed , providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , miscellaneous civil , providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge. , supplying, providing and laying vitrified tiled floor, wall on cement screed using 600 x 600 mm vitrified tiles. total thickness of screed and tiles to be 30 mm. including lying 125mm high skirting all round. laid area of wall, floor and skirting measured and paid , wall tiling ( 1.8 mtr height ) , floor tiling , providing and fixing floor cover with quick access to sub floor utilities galvanized steel chequer plate for cabling modular factory finished widely for cabel laying to withstand heacy traffic movemetn of heavy matirials thelid has been designed to withstand for heavy loading, all lids are galvanized to prevent corrosion, with the larger lids having substantial underbracing to give the required strength, complete as directed and instructed. , providing and applying pest and rodent control for the required in all respect including guarantee for the 18 months , providing & layi g approved shade minimum 18mm thick granite slab in flooring, window cills etc over cement morter of 1:4 in wastage, labour. complete as directed and instructed. , provide and fixing wall paneling up to the ceiling height in radiation therapy processing room, passage and the control room, using 18 / 12mm thick high quality plywood paneling with 4mm thick veneer finished, cut to shape and size and fixed to wall in straight line including all supports, screws etc complete as per direction of engineer in charge. , p / f trap door in false ceiling with acp panel in shutter and frame fixed ovwr 50x50x2 mm thick aluminumhollow swction with epoxy sealant as per manufacturer specification suspended from ceiling with suitable ms supporting system as per site condition, including p / f 32mm thick insulation on trap door complete as directed and instructed. , painting , providing and applying oil based internal paint as per the manufacturers specification to the interior surface of masonry walls, underside of roof slabs in ups room , control room , passages, of approved colour and shade with minimum two coats of paint. item to include preparing the surface with necessary approved fillers, making good by touch up etc. to give the desired finish , all complete. rate to include cost of the tools, tackles, labour, equipment, etc. ( above wall tiling ) , providing and applying exteriorpaint widly used to mactch exisitng colour schemewaterproofing paint, scrap and clean the surface, applyprimer as base coat, over the primer coat apply two coats or more paint approved color as per manufacturers sepecification all inclusive of labour, scafolding, safety precautions etc complete as directed and instructed. , providing & applyingenamel paint to wooden or steel doors, scrapping, cleaningthe surface, washingandfillingthe crevices with approved paste / putty as filling sealant & applying the paint with one metal primer base coat, two top coats or more over the primer as per manufacturers specification, including, labour, scafolding, safety precaution etc complete as directed nd instruted. , furniture , providing and fixing 5w x 7h, 38 mm thick, double leaf doors in solid hard wood core ( phenyl formaldehyde bonded ) flush shutters both faces commercial ply including ist class c.p.t.w. lippings all around, lock plate and complete hardware, finished with both sides 1.0 mm thk. laminate as per specifications with grooves and clear / frosted glass as per design / detail complete in all aspects with necessary heacy duty hardware fixtures to mactch exisitng hardware fixtures already installed to maintain unifarmity as standerdization as per per the furniture drawing complete as directed and instructed. , repairing and alterations to existing wooden doors, by changing ss hinges, ss fittings and shutters to be 40mm thick, flush type with teak veneers on both sides open type. inclusive of fixing heavy duty automatic door a closure, two doors handles per shutter concealed night latch locking device, etc. complete. , floor mounted storage cupboards within bhabhatron room; to store: accessories. ( location: tomotherapy room passage ) size: 200 cm wide x 250 cm high x 60 cm deep ( 19mm thick commercial grade ply ) , open type cabinetwith shelves with 18 mm thick high quality plywood laminated with 0.9mm thick melamine laminates on both side of approved colour and make with 1 numbers of open type shelves 210cmx200x50cm size with 6 horizontal and 3 vertical partitions inside the therapy room with partitions for immobilization devices, electron applicator and cutouts. type and utility should match with the existing work station. provide necessary drawer 2 nos and shutter 2 nos as per the requirement from the radiation physics division. edges should be finished by machine press. all finishes and quality to be instructed by the engineering in – charge. , providing and supplying officers chair with net back revolving type.the contractor shall furnish one year warranty. economically designed and mat finish. , changing room partition ( 3x4 ) , electrival & lv works , main distribution lt panelsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 1 no 250a tp 25ka mccb + neutral link with built in adjustable o / l, s / c & e / f. mccb with rotary handle mechanism. outgoings : 1no 125a tp mccb with rotory handile machanism for ups, 1no 100a tp mccb with rotory handile machanism for chiller, 1 no. 125 a tpn mccb for hvac & 1 no 63a 25ka tpn mcb with mechanism for hvac unit. busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium .incoming and outgoing cables shall be top of bottom entry only. , ups output panel boardsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 1no 125a tp 25k mccb + neutral link with built in adjustable o / l, s / c & e / f mccb with rotary handle mechanism outgoings : 1nos. 100a 25ka tp mccb with rotary handle mechanism, & 3nos. 40a tpn mcb for db busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium . incoming and outgoing cables shall be top of bottom entry only. , electrical wiring & cabling , distribution boards supply, erection, testing and commissioning the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adaptor box above the db shell also be includeddistribution box 8 way 7segment mcb dbi / c 63 amp fp mcb 1 noo / g 63 amp dp mcb 3 nos o / g 10 / 16a sp mcb 18 nos including all interconnections and other accessories etc as reqd , supply, installation, testing andcommissioning 100a tpn mccb with water proof enclosure including earthing and all other required accessories as per site conditions. for near chiller , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , lt cables supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4r 50sq.mm copper flexible cable truebeam ups incoming & outgoing , 4r 25 sq.mm copper flexible cable for ups input & output and machine , 1c 25 sq.mm copper flexible cable for earth , 4c 16 sq.mm copper flexible cable for chiller , 4c 10 sq.mm copper flexible cable for ac , 4c 6 sq.mm copper flexible cable for db , 12c 0.75sqmm copper flexible cable with pvc conduit for chiller to control panel at console room & warning light , 1c 6sq.mm copper flexible cable for db earthing , cable terminationssupply, erection, testing and commissioning for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4r 50 sq.mm copper flexible cable , 4c 25 sq.mm copper flexible cable , 1c 25 sq.mm copper flexible cable , 4c 16 sq.mm copper flexible cable , 4c 10 sq.mm copper flexible cable , 4c 6 sq.mm copper flexible cable , submain ups and raw power circuits , supply & laying of 2r 2.5sqmm 1r 2.5pvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. , supply & laying of4 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , point wiring supply, installation, testing & commissioning of 3r 1.5sqmm pvc insulated frls copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site. , primary point , secondary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1no13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. ( ups power ) , supply, installation, testing & commissioning of 1no 6 / 16a socket and 1no switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. , installation of light fittings , supply, erection, testing and commissioning of 2 x 2led 36 watts recessed mounting fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed. , supply, erection, testing and commissioning ofled 18 watts recessed mounting down light fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed , supply, erection, testing and commissioning of single3w recessed fixed type led fitting with electronics ballast and all accessories and interconnecting with 3 core 1.5 sqmm pvc insulated frlscopper wire and fixing the same in the ceiling. , data, voice & network , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. , supply, fixing, testing and commissioning of information outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 4u communication rack , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , supply, fixing, testing and commissioning of cat 6 telephone cable . , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , earthing , supply and installation of 4 way earth bus with accessories as required , supply, installation, testing & commissioning of copper earthing with 600x600x3mm copper plate and 25x6mm copper flat bar confirmingis:3043 with the provision for watering & inspection chamber. , perforeated type gi cable tray , supplying, fabricating, erecting and connecting the following 1.6mm thickness gi perforated type cable trays with necessary supports, tees, elbows, bends, bolts and nuts and any other associated accessories to complete the job. 150mm ( wide ) x 50mm ( collar height ) , supply & fixing of 50 mm pvc pipe for cc tv, irm and speaker cable pulling , warning light supplyfixing testing & commissioning of warning light, led green, yellow, red, + power supply . , emergency stop switch supplyfixing testing & commissioning of emergency switch, 3 no. no, element with box , supply fixing & commissioning of lmo switch indicator &buzzer, ss plate with all accessories , supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 10 sq.mm copper flexible cable for ac , 1c 6sq.mm copper flexible cable for db earthing , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , supply testing & commissioning of panasonic make telephone instument with caller id , cctv the camera should be compitable with exisitng cctv system as standerdization, sample must be got approved before supply in bulk. , 16 channel dvr ful hd , hd outdoor bullet camera , hd dome camera , wd hard disk ( dvr ) 1tb , moniter ( 19.5inch ) , camera power supply ( 10amp ) , sdmi cable ( 3 meter ) , bnc conector , dc pin conector , wire 3+1 ( heavy wire ) per / meter , junction box for camera , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1 no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplid. , supply testing commissioning of token display system , firefighting works all devises should be compitable with exisitng system as standerdization, sample must be got approved before supply in bulk. supply, installation, testing & commissioning: , smoke detectors bunker 8 nos; maze 2 nos; ups 2 nos. , response indicator. , manual call bell , hooter , cu. ar. 1.5 sq.mm. cable , fire extinguisher 5kg bunker 4 nos; ups 1 no. , hvac works , supply, installation, testingandcommissioningofaircooledscroll chilling machines having actual capacity of 38.4 tr at chilled water inlet / outlet temperature of 12.0 deg. c / 7 deg. c having evaporator fouling factorof0.000018m2.k / w suitable for operation on refrigerant r 407c or eco friendly gascomprising the following complete as required. chiller capacity should not less than 38.4tr ( followingsafetyfactorwillinbuiltwithchillerunit sppr, under / over load protection, phase reverse protection, hp / lp trip signal interlocking, auto / manual test mode facility / run time equalization for multiple compressor, password access for authorized handling, pt 100 rtd sensor for chiller unit, interlocking for chilled water flow swtich ) 135kw ( 38.4tr ) , air handling units supply, installation, testingandcommissioningoffactorybuiltfloor mounted doubleskintypehorizontal / verticalairhandlingunits made of43+2mm thick panels consisting ofpreplasticizedg.i. casing of thickness 0.8 mm outside layer and 0.8 mm plane gi at inside layer with cfc free p.u. insulation of density 42 ( +5% ) kg / m3 factory injectedbetweenthem byinjectionmouldingmachine, completewith didwbackwardcurvedcentrifugalfanwithvfdstarterdriven, suitablefor50mm wgstaticpressure, coilsectionwithaluminium blue finned copper tubes ( tubes thickness not less than 0.41mm ) cooling coil of 6 row deep, filter section with 50mm thick washable synthetic type air pre filters, belt drive package with tefc drive motor suitable to operate at 415 ± 10% volts, 50hz, 3 phase ac supply, motor should be compatible with vfd, drain connections, stainless steel ( 18g ) drain pan, necessary vibration isolation pads & accessories:and piping as per the norms duly insulated with requires thick nitrile rubber. ahu starterpanelshouldhavevfdandvfdbypassoption, should have plc based control and plc bypass control for manual mode. panel should provide with heater control. note: temp and rh sensor to be included with control wiring. noadditional cost will be given for the same. 30.5 tr 12200cfm 50mm tsp ( 1 working +1 standby motor ) , supply, installation, testing and commissioningof fcu 2 tr , supply, installation, testing and commissioningof primary pump 102usgpm 15m head. , supply, installation, testing and commissioningof expansion tank ( 100 ltr ) with air separator, air vent and pressure maintaining pumping unit. , supply, installation, testing and commissioning of chilled water ms pipe with supports, hardware etc. , 80 mm dia with 32mm nitrile insulation with 26g al cladding , 25 mm dia with 19mm nitrile insulation with 26g al cladding , pvc drain pipe having pressure holding of 8kg / cm2drain piping complete with all accessories with 9mm nitrile rubber insulation with supports , 32mm dia , 25mm dia , supply, installation, testing and commissioningof valves & guages as follows with 32mm nitrile insulation for chw line: , butterfly valve , 80mm dia , 25mm dia , y strainer , 80mmdia , 25mm dia , flexible connection80mmdia , nrv valve80mmdia , 3 way valve , 80mm dia , 25mm dia , ball valve 25mm dia , airvent with ball valve , temperature gauge , pressure gauge , sitc of gi sheet metal rectangular duct with support, hangers, rods, frames, anchor fastners, etc. , 24 gauge , 22 gauge , supplying & erecting accoustic insulation lining on the ducts having 15mm thick open cell nitrile rubber armasound to reduce noise , supplying & erecting thermal insulation on the ducts having 19 mm closed cell nitrile rubber. exposed duct should cover with 26g al cladding , sitc of canvass connection for ahu machines , sitc of control cabling in between for fcu and ahuunits , sitc of fire damper , sitc of fire actuator , sitc of supply / return air grill with vcd , supply, installation and commissioning of duct strip heaters with thyristor control of necessary capacity made of ss strip ( finned / finless tubular type ) complete with rh sensor, industrial grade heating elements, protection against overheating, on / trip status, air flow switch, grounding terminals, terminals for power & control, intermediate control wiring for integration etc. for full automation working to achieve rh level of 40 60% non condensing in the treatment room. ( rating / capacity considered to be specified by the bidder ) , dismantling of existing hvac systems ahu, piping, valves , ducting / copper piping / drain piping / units / hi wall split unit all complete as per instruction as nad directed by oic es , supply and fabrication of ms structure include one coat primer and one coat enamal paint. , dismantling & re installing exisitng ac chiller plant including its roofing at terrace including disconnection of chilled water ms pipe lines, extending same till new location, with required insulation and necessarru hardware as directed and instructructed. , turnkey works at tmh mumbai , civil works : , labour charge only for removing and re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing and refixingavailbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete allonly fixing available door shutter with necessary repairing , removing existing false ceiling of any material and any size with all necessary allied works, removing out debris out of tmh premises , labour charges only for carefully removing and taking out existing wooden partitions ( partly glazed, partly panneled or fully panneled with shutters glazing etc. at all floor levels and locations including removing the existing mongery fittings fixtures locking arrangement and handling over the same to t.m.c all complete as directed , providing wood work with 1st class c.p. teak wood in frames for doors windows, ventilators, air condition frames, clear story window, false ceiling and partitions etc.wrought framed and fixed in position including applying one coat of approved wood primer to the exposed surfaces and tow coats of bitumastic paint to the surface of wood in contact with masonry / concrete etc.complete. in frames of doors, windows, ventilators and clear storey windows etc. fixed with m.s hold fast of size 40x3mmx150mm long bend to shape and embeded in cement concrete 1:2:4. , providing and fixingapproved quality machine pressed phenol formal dehy de bonded commercial / marine ply wood of approved size and fixing the same with necessary nails / screws / adhesive in partition cupboard shelves / ktichen / cabinets / flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick t.w.lipping patti at all exposed edges with nails / screws / hardwares / adhesive wastage in cutting, transportation etc. complete all.commercial ply19mm thick ply , providing and fixing 1.0mm thick laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified. 1.00 mm thick , providing and fixing cabinet made up of 19 mm. commercial ply for top, bottom, sides and shelves and 6mm commercial ply for back side.door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.0mm thick plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in drawing etc.and all exposed edges lipping with 6mm laminate finishthick t.w.lipping patti.locking arrangement withmultipurpose lock etc. all inside areas shall be .80mm thick approved colour laminate etc. with inner side 0.8mm thick laminatewith shutter , providing making and supplying computer table made out fo 19mm commercial ply for table top, mounted on the vertical side fo 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves and shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polishasshown in drawing drawer and wooden key board drawer with heavy sliding channels, withhandle for shutter, cable manager drawers all edges shall be lipped with 6mm thick t.w. lipping patti. all exposed faces should be 1.0mm thick laminate and non laminated area should be french poll shed including cost of other materials labour etc. as per drawing.computer table with all inner surface with 0.8 mm thick laminate , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick made of g i sheet having galvanizing of 100 gms / sqm ( both sides inclusive ) and electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing fixing door frame and shutter side hung to consist of partly glazed partly panneled / fully panneled / fully glazed with 5.5mm thick glass sheet and quality plain or frosted of bajri glass fixed with two way pvc lining / rubber gasket to ensure notes tightness and no rattaling and panneling with 12mm thick nova pan or ancholam finished on both side as required using extruded alumimium section forshutter frame24254545mm satin finish anodized including p / f push pull plates handles and heavy duty fittings like tower bolts, motice lock with keys hinges of 5 inch or 6 inchas per requirement hydraulic door closer / floor spring of suitable capacity etc complete.with powder coated , painting work providing & applying one / two coats of primer two coats of paint as mentioned below first quality paint to the required colour scheme and as per manufacturers instructions / specificationsto the walls, beams, columns, ceilings, partitions, doors etc. including removing existing paints , nails , screws , battens etc. and thoroughly scrapping the surface with sand papers filling up crevices and levelling with putty to obtain smooth surface ie. complete surface preparation etc. complete as directed to the entire satisfaction of engineer in charge. , with two coats of primer and two coats ofpaint , using luster paint , using synthetic enamel paint ( oil paint ) , providing and applying three coats of white wash to ceiling etc. including removing existing nails , screws , battens etc. andthoroughly scrapping the surface with sand papers, filling up the crevices and levelling with putty if necessary adding, required quantity of adhisive to obtain good finish to surface complete as directed. , civil work breaking:dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandur stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including disposing / taking away the debris outside the premises & disposing as per the guidlines of statutory authoritised. ) , granite tiles:providing & laying 8 to 10mm thickgranite tile of size 300mm x 600mmfor flooring / dado / skirting laid over a bedding of c.m. 1:335mm thick in true plain line & level curing. finishing the joints etc. complete.in flooring & in dado / skirting , electricalsworks , point wiring : point wiring for light / fan / bell with isi mark 3 x 1.5 sq.mm ( p+n+e ) . frls pvc insulated copper conductor ofmake in surface / recessed heavy class pvc casing capping / conduit with modular switch ceiling rose / batten holder / slanting holder boxes etc. with circuit labling / marking / ferruling complete. , primary point upto 4 mtrs length , primary point length 4 mtrs to 7 mtrs , primary point length7 mtrs to 10 mtrs , secondary point extending from primary point upto 4 m , dismantling: carrying out assigned jobsof dismantling the existing light, fan, bell, independent plug point wiring of all types with accessories and cable / switchgear , supply & installation of power point ( inclusive of 2no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , supply & installation of power point ( inclusive of 1 no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , telephone point : supplying and instllation of telephone point inclusive of telephone instrument, telephone socket with back box , plate, laying two pair0.5 mm gauge unarmoured telephone wire d.o.t approved, make through conduit / casing caping. , supplying and laying of 2 core audio speaker cable throughconduit / casing caping / cable tray. , sub mainsmains : providing heavy duty pvc casing caping / conduit, supplying and erecting mains with copper conductor pvc insulated frls of 1100 v ac grade wire with circuit labling / marking / ferruling complete. , 2 x 1.5 sq mm + 1.5sqmm earth wire , 2 x 2.5 sq mm + 1.5sqmm earth wire , 2 x 4 sq mm + 2.5 sqmm earth wire , light fixturessupply of led fixtures surface / suspended / recessed mounted luminaires , led light fixture duraslim 15 watt, round6500k, , led light fixture full glow 2ft x 2ft 6500k , distribution boards supply, installation, testing & commissioning dbs , spn db with metal door, 12 way, ip 43, inclusive of required rating mcb, rcbo , tpn db with metal door, 8 way, ip 43, inclusive of required rating mcb, rcbo , hvac works , hvac works ( low side ) fan coils units ( ceiling suspended type / high wall ) supply, installation, testing and commissioning of gi powder coated horizantal ceiling suspended / high wall fan coil units complete with fan, 3 speed motor, 3 row deep cooling coil, 5 mm external static, filters , copper connection, canvass connection ( if required ) , supporting arrangement, electrical wiring etc. the complete fan coil unit shall be in line with the standard specification. the capacity of fan coil units shall be as follows. proper supporting system for fcu to be provided & will be in contractors scope. 800 cfm ( 2 tr ) , hvac works ( low side ) : supply & installation of 2 wayvalve , hvac works ( low side ) : supply & installation of digital thermostat including all accessaries , mountings, wiring between thermostat & unit, terminations etc. , supply, installation testing and commissioning of the following ball valves without strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , supply, installation testing and commissioning of the following ball valves with strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , hvac works ( low side ) :supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class o applied by suiatable adhesive, as per specifications and as required complete in all respect 32mm, insulation work involve removing of old insulation on chilled water pipeline and installing new insulation. , hvac works ( low side ) : providing and fixing in position the following upvc heavy class cut to required length and installed with screw joints including the necessary fittings, supporting arrangements like clamps etc. ( bends, tees, unions, sockets etc ) duly insulated with class o 6 mm thick nitrile rubber insulation as per specifications. 25 mm dia , hvac works ( low side ) supply, installation, balancing and commissioning offabricatedat site gss sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of .63mm thickness complete as required. , hvac works ( low side ) supplying, installing of external thermal insulation on ducts of al faced / closed cell nitrile rubber insulation with anti microbial properties with duct insulation with density 40 55 kg / cum complete as per specifications. •thermal conductivity of insulation material shall not exceed 0.035 w / ( m.k ) & r value as mentioned in ecbc 2008 at mean temperature of 24 degree c as per astm c518. . class o insulation with aluminum foil. • moisture diffusion resistance factor or ‘?’ value of insulation material shall be minimum 7, 000 without any external barrier as per en 13469. • the insulation material shall have fire performance such that it passes class 1 as per bs476 part 7 for surface spread of flame and also passes fire propagation requirement as per bs476 part 6 to meet the class ‘o’ fire category. 25 mm thick. , hvac works ( low side ) supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 300 mm dia , hvac works ( low side ) supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing and commissioning of gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications , dismantling, removing of oldflexible ducting , pipelne, insulation, fcu ( 3nos ) , griil, diffuser etc loading, unloading, lifting shifting, etc and disposing the same outside tmh premises with proper housekeeping complete in all respect , networking supply, installation, testing and commissioning of lan cable room no. hbb b 002 4 nos. of network points, room no. hbb b 003 2 nos. of network points. total networks points. = 6 nos. , turnkey works for site preparation of gmc, shillong , civil shielding works , complete dismantling works inside bunker and console room, of plain cement concrete, flooring, brick work, false ceiling to any depth and width, at all levels below & above ground level of any shape, removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. rate shall include for dismantling of plain cement concrete / brick work by manually / mechanical means with necessary tools and plants, scaffolding, water and power charges, cleaning the surface, preparation of surface etc. rate shall include for stacking the serviceable materials and disposing the unserviceable materials / debris away from the site premises by mechanical means including loading, unloading, clearing the site etc. complete, as directed. ( measurement is done for floor area only ) demolishen of the walls are as per approved drawings , providing and casting in situ cement concrete m 25 ( concrete density 2.35 gms / cc ) of trap / granite / quartzite / gneiss metal for r.c.c. walls as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing complete. ( excluding reinforcement ) . with fully automatic micro processor based plc with scada enabled reversible drum type concrete mixer. with natural sand. for concrete shielding and bunker door wall as per aerb approved drawing , providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the rcc structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 ( 5 parts integral crystalline slurry : 2 parts water ) for vertical surfaces and 3 : 1 ( 3 parts integralcrystalline slurry : 1 part water ) for horizontal surfaces and applyingthe same from negative ( internal ) side with the help of synthetic fiberbrush. for bunker and console area , civil interior & furniture works , 50mm thick cement concrete flooring finished with 3mm thick vinyl flooring location: ups room , 600mmx 600mm vitrified tiles with 100mm matching tile skirting. providing and laying approved quality, colour, design and shade fully homogeneous 600 x 600 mm ( thickness to be specified by the manufacturer ) vitrified tile flooring ( marbonite or granamite, confirming to is code 15622 with water absorption less than 0.08% ) flooring in pattern as detailed in drawing or as directed by the institute and grouted with matching colour approved quality readymade grout, curing, cleaning etc to required line level etc. all complete at all leads, lifts and heights to the entire satisfaction of the institute. providing and fixing 2 3mm thick pop protection over polythene covering sheet to flooring areas till handed over and cleaning, etc all complete as per drawings & specification. ( linac room and console room ) , two coats of plastic emulsion paint over 2 coats of wall putty including primer. location: ( ups room and outside shielding wall ) , providing and laying high quality and density type vitrified wall tile of 1200 mm height in radiation therapy room and the control room, laid on 20mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) or as per the appropriate mortar rquired to hold the wall tiles together, in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge upto false ceiling level. location: ( linac and control console room ) , pest and rodent control from pci location: linac room, control console and ups room , acoustical tile for ceiling with light weight insulating material of high quality supported on grid or finished seamless with support above ceiling. to be finished with white paint or powder coated with white paint, if metallic. the false ceiling panels should be of reputed brands. location: linac room, control console and ups room , constructing cable trenches 300mm wide and 300mm deep as per the drawings , preparing and fixing openable covers of vitrified tiles fixed in the with ability to sustain a load of 200kgs to be placed on the trenches 300 mm wide, all works complete , furniture , revolving chairs height adjustable, medium back with hand rest , skylight , wall mounted storage cupboards within linac room; to store: dosimetry & qa items, linac accessories. ( location: treatment room ) . size: 2m wide x 1.2m high x 0.4m deep ( 19mm thick marine grade ply ) , 40mm thick plywood door with teak wood frame, including all accessories. size 2m x 2.2m , wooden tables for workstations. size: 3 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: console , wooden tables for workstations. size: 4 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: tps , plumbing works , supply & installation and commissioning of chiller inlet & outlet equipment flange & union , supply & installation and commissioning of pressure gauge , supply & installation and commissioning of thermometer , supply & installation and commissioning of auto air vent , supply & installation and commissioning of drain valve , supply & installation and commissioning of chiller water copper piping 15 / 8 18 gauge with insulation 19mm thick , supply & installation of chiller water pipe nylon with wire mesh hss slive flexible 40mm with insulation 13mm thick , supply & installation and commissioning of ball valves 40 mm , supply & installation and commissioning of y strainer 40 mm , supply & refilling of dm water , supply & installation and commissioning of water panel with 2 nos pressure gauge and 5 nos valve, 2 nos thermometer , hvac works , ductable a / c units along with low side works ( up to 50 running meters ) for complete installation & commissioning of ac. supply , installation , testing & commissioning of aircooled ductable split air conditioner with ceiling suspended idu and all standard fitting, gss sheet metal duct ( insulation using resin bounded glass wool with 7 micron aluminium foil ) for air distribution 22 / 24 g, idu ss drain pan as per specification complete with suitable capacity drive motor , aircooled condensor with all accessories , hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, vibration isolator pads, structural support for fixing idu / odu, safety devices including thermal protector, pressure release valve , overload relay single phase preventer etc, power wiring and control cabling ( indoor to outdoor ) , thermostat wiring, high low pressure cut out suitable for 3 phase 440v supply etc complete as required. ( warranty 3 years ) for bunker and console 5.5 tr working and 5.5tr stand by , split units with required copper piping and drainage outlet lines ( for ups room 2tr working and 2tr stand by ) with auto timer switch , 2 litre capacity dehumidifier ( for bunker 2, console 1 ) , electrical works , main lt panel supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 250a 3p mccb with rotary handle mechanism 1no with necessory interlocking arrangement out goings : 100a tpn mccb with rotary mechanism 2 nos. 63a tpn mccb with rotary mechanism 3 nos. 40a tpn mccb with rotary mechanism 1 nos. incoming and outgoing cables shall be of top or bottom entry only. , ups output panel board supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 100a 3p mccb with rotary handle mechanism 1no out goings : 100a tpn mccb with rotary mechanism 1 nos. 40a tpn mccb with rotary mechanism 2 nos. incoming and outgoing cables shall be of top or bottom entry only. , distribution boards supply, erection, testing and commisioining the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adoptor box above the db shell also be included , power & lighting dbs 6 way etpn mcb db, all mcbs shall be of c curve type only meant for lighting application i / c 63 amps fp mcb 1 no o / g 6 / 10 / 16 / 25asp mcb 18 nos including all interconnections. , ups dbs 4 way etpn mcb db, all mcbs shall be of c curve type only meant for ups power application i / c 40amps fp mcb 1 no o / g 10 / 16asp mcb 12 nos including all interconnections. , supply, installation, testing andcommissioning 100a 4p mcb with water proof enclosure including earthing and all other required accessories as per site conditions.for a / c & chiller , supply, installation, testing andcommissioning 100a mccb with ms enclosure including earthing and all other required accessories as per site conditions. for ups incoming & outgoing , l.t.cables supply, laying, testing and commisioining of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 4 sq.mm cu. ar. cable ups db incoming , 4c 10 sq.mm cu. ar. cable for pdb & hvac input cable , 4c 16 sq.mm cu. ar. cable for chillerinput cable , 4run 25 sq.mm copper flexible cable machine incomming & outgoing wiring , 4run 25 sq.mm copper flexible cable ups incomming & outgoing wiring , 1run 25 sq.mm copper flexible cable for earth cable , 4 core 50sq.mm copper ar. cable for upsin & out going power cable , cable termination supply, erection, testing and commisioining for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4c 4 sq.mm cu. ar. cable , 4c 10 sq.mm cu. ar. cable , 4c 16 sq.mm cu. ar. cable , 4run 25 sq.mm cu. flexi. cable , 1run 25 sq.mm cu. flexi. cable , 4 core 50sq.mm al. ar. cable , submains ups & raw power circuts , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( lighting & raw power circuit mains ) , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( ups circuit ) , supply & laying of 2r 4sqmm 1r 2.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( split a / c / power socket circuit ) , supply & laying of2 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , supply & laying of3 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for lmo switch wiring. , supply & laying of8 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for warning lamp wiring. , supply & laying of12 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for chiller remote panel wiring. , point wiring supply, installation, testing & commisioning of 3r1.5sqmm pvc insulated fr copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site condition , primary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1nos 6a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( raw power ) , supply, installation, testing & commissioning of 1no 6 / 13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( ups power ) , supply, installation, testing & commissioning of 1 no 16a switched socket with moulded frontplate gianodised enclosureand other associated accessories as per the site conditions. ( with indicator ) , installation of light fittings , supply, erection, testing and commisioining of 600mm x 600mm 36w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of 6 x 6 18w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of single12 v, 15w led fitting ( or ) 230v, 60wrecessed fixed type halogen fitting with copper ballast, lamps all accessories and interconnection ( dimmer light ) , supply, erection, testing and commisioining of led strip light , data, voice & network ( consile room & tps room ) , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. ( voice and data cable ) , supply, fixing, testing and commissioning of infermation outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 10 / 100 / 1000 mbps 24port t switch with 24 port patch panel , supply of 1 mtr pach card , earthing , supply & laying of 8 swg bare cu. wire , supply and installation of 12 way earth bus with all accessories as required. , supply, installation, testing & commisioning of 10 feet long 600 x 600 x 3mm copper plate or chemical earth pit for machine and ups netural and body earth , miscellaneous , supply & laying of20mm pvc hose , supply & laying of25mm pvc hose , supply, fixing of 105 x 50 mm cms tray for control room , warning lamp em off switch & lmo switch , supply & fixing of emergency stop switch and system on switch with base box , supply and fixing of magnetic door switch , supply, erection, testing and commisioining of led warning lamp for red, green & yellow . , supply, , erection, testing and commissioning of last man out control unit, last man out switch with indicator, buzzer and external wiring kit ( 1.0 sq.mm cu. wire & pipes ) , fire alarm system , supply, fixing, testing & commissioning of 2 zone conventional fire alarm panel with complete set. , supply, fixing, testing & commissioning of conventionalsmoke detectors with base , supply, erection, testing & commissioning of conventional manual call point. , supply, erection, testing & commissioning of conventional hooter / sounders , supply and laying of 2 core 1.5 sqmm copper armoured cable , carbon di oxide type fire extinguisher of 4.5 kgs. capacity, co2 gas filled in brand new seamless cylinder with powder coated finish, made out of manganese steel, with wheel type valve, discharge nozzle, bend & horn, signages etc. complete, , cc tv , supply, fixing, testing & commissioning of hd ir ccd 1 / 3” color camera. ( doom or bullet modal camera ) , supply, fixing, testing & commissioning of hd mini speed dome ir camera. with 10 to 15x zoom, auto iris lens, rs485 control ptz camera , supply, fixing, testing & commissioning of 4 chenal hd dvr , supply, fixing, testing & commissioning of ptz keyboard with joystick , supply, fixing, testing & commissioning of 24” led tv , supply, fixing, testing & commissioning of 12v dc power supply for camera , supply and laying of 3+1 rg 58 cctv cable , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplied. , turnkey works for site preparation of dr. b. borooah cancer institrute, guwhati , a ) civil works , demolishing rcc work including stacking of steel bars and disposal of unserviceable material as directed for all levels , dismantling and removing the existing door and window frame ( chowkath ) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. ( ii ) area of door / window above 3.00 m2 , demolishing cc floors of various thickness including top layer and base course and disposal of debris as directed for all levels. , providing and laying plain / reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) ( i ) using mixer machine ( a ) in substructure up to plinth level p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , ( b ) in super structure from plinth level up to 1st floor level.p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , providing form work of 12mm thick plywood board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. ( b ) floors etc. above 200mm in thickness. , supplying, fitting and fixing in position reinforcement bars conforming to relevant i.s. code for r.c.c. work / r.b. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20g annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. ( no extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate ) ( upto 1st floor level ) a ) from primary producer ( i ) tmt corrosion resistant steel ( crs ) reiforcement bar , plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete ( shuttering where necessary shall be measured and paid separately ) . ( a ) in prop 1cement: 3 sand :6 coarse aggregate by volume , 20 mm thick cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b ) on fair side ( backing coat 10 mm and finishing coat 10mm thick ) a ) in cement mortar 1:3 , providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile ) / white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. ( cement plastering to be measured and paid separately ) . ( coloured pigment should be in conformity with colour of slab and as approved and directed by the department ) . ( iii ) deluxe quality ( i ) with fix a tile , providing vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tilewhite cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) c ) delux range ii ) of size 1200mmx1600mm and above , providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile / white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) . iv ) of size300mmx900mm and above , supplying fitting and fixing of upvc partition wall 5 mm frosted glass , supplying fitting and fixing of upvc double leaf door 5 mm frosted glass , supplying fitting and fixing of upvc sliding door door 5 mm frosted glass , supplying fitting and fixing of upvcsliding window 5 mm frosted glass , providing wood work in frame ( chowkaths ) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with c.c or brick masonry wall including supplying, fitting and fixing with m.s. hold fast ( 40mmx3mmx250mm ) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with c.c and masonry as directed and specified. ( a ) with sal wood , providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent i.s code including oxidised iron butt hinges ( 100mm x 75mm x 3.5mm ) 6 nos with necessary wood screws. a ) decorative type face panel and block board core. ( iii ) 30 mm thick . , supplying, fitting, fixing and painting where necessary ( one coat primer and two coats of paint ) suspended ceiling which includes g.i. perimeter channels of size 0.55mm thick ( having one flange of 20mm and another flange of 30mm and a web of 27mm ) along with perimeter of ceiling, screw fixed to brick wall / partition with the help of nylon sleeves and screws, at 610mm c / c. then suspending g.i. intermediate channels of size 45mm ( 0.9mm thick with twoequal flanges of15mm each ) from the soffit at 1220mm c / c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with g.i.cleat and steel expansion fasteners. ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c / c. then 12.5mm thick square edge fulltone / sundance / cratone / louvertone / textured. gypboard panels of size 595mmx595mm ( conforming to is:2095 1982 ) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c / c. screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for gypboard complete at all levels as specified and directed. ( for light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary ) . ( glass wool to be measured and paid separately ) . m / f frame work with acoustic type slit gypboard ( louvertone ) tiles ( nrc value 0.72 with 50mm glass wool mat backing ) 12.5mm thick. , providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. , wall painting ( two coats ) with plastic emulsion paint on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. ( a ) .plastic emulsion paint , extra over item no 13.4.7 above for every subsequent coat of wall painting with plastic emulsion paint. ( a ) .plastic emulsion paint , water proofing of chajjas, roof slabs, terraces, sunken slabs, septic tank, oh tank, raft slab in basement, walls etc. ( b ) using polymer based cement mortar. , supplying fitting and fixing of sky view , providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections ( i ) square section ( ii ) rectangular hollow section of specification rsh / shs and ( iii ) m.s. circular hlollow section of grade 210 including purlins, bottom runners and providing m.s. cleat, m.s. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a ) using rhs / shs of grade 310 conforming to relevant i.s. code 4923 : 1997 , providing pre painted galvanized ironsheetroofing ( ppgi ) at all levels including fitting and fixing with self drilling, self tapping screws complete. ( roof trusses, purlins etc. to be measured and paid separately. ) as directed by the departement ( v ) 0.80 mm thick , earth / sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. ( b ) with hill sand obtained by truck carriage loading and unloading, and carriage to the site of work. , providing soling in foundation and under floorwith stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. ( a ) .brick on flat soling. , 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure ( ii ) in superstructure above plinth level up to 1st floor level. ( a ) . in proportion 1:3. ( 1 cement:3 sand ) , supplying, fitting and fixing chain link fencing of 10 s.w.g, g.i. wire 50mm x50mm mesh fitted to m.s angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of g.i wire 10 s.w.g at top, middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to m.s angle iron post in p.c.c base etc. with following. a ) corner and end posts with m.s angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. , supply, installation, fixing of dry chemical powder fire extinguisher confirming to is: 2171 with isi mark and co2 cartridge will be confirming to is: 4947 with isi mark, powder will be confirming to is: 4308 with isi mark ( 5 kg ) , wall panelling with ply and mica pesting , finishingold / new wall with water proofing weathercoat smooth anti fungal premium textured exterior finish ofrequired shadeafter clering and clearing the surfaces etc.including scaffolding complete as directed at alllevels ( two coats ) . , b ) external electrification works , supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor / wall mounting compartmentalize panel board of size 0.95m x 1.30mx 0.40m made of 16 swg1.66 m thick c.r. sheet and40mm x 40mm x 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of red oxide metal primer and 2 coats of enamel paint. the panel board is to be erected in 1 : 3 : 6 pcc foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 400a 4pole mccb or switch fuse unit as incomer and provision for 4nos dp or tpn out going as specified and directed by the deptt. confirming to ip 43 protection comprising of the following electrical items: 1. 40mm x 5mm 4 strip copper bus bar 1.20 m length each i20mm x 3mm 4 strip copper bus bar 0.5m each 4 sets 2. digital 3 phase voltmeter accuracy class 0.5 1 no 3. digital 3 phase ammeter accuracy class 0.5 1 no 4. pilot lamp with integral ckt led 110 230 v ( red, yellow, & blue 3 no 5. voltmeter & ammeter selector switch 2 no 6. 2 a slide fuse unit 3nos ( incoming & outgoing switch gear of reqd. rating will be measured and paid separately ) , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt.. 3 & 1 / 2 core a2xfy 240.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from main distribution panel to machine panel , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 185.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from panel to ups and ups to machine control panel , supply, installation & testing of copper plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. g.i. medium duty watering pipewith g.i. fittings such as socket, tee, elbow, nipple and 50 mmx40 mm g.i. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm c.i. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . note:for machine, chiller and ups. , extra for using salt ( 5 kand charcoal ( 96 kin g.i. / copper plate earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . , supply, fitting & fixing 20 mmx3 mm copper strips drawn on vertically or horizontally on building wall / parapet wall in surface system complete with supply of brassnuts & bolts, screws etc including riveting, soldering and making connection as approved by the deptt. ) with earth electrode copper strips and lightning arrestor etc. as specified and directed by the deptt. , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 400.00 sq.mm.3 & 1 / 2 core armoured u.g. cable , c ) internal electrification works , wiring for circuit wiring with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface / recessedpvcconduit wiring system. with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for door interlock, fault ceiling light, laser, cctv, public adress system, ceiling fan, emergency switch , 2.7.1wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts pvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit note:for 6a and 16a power points , 2.7.2wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduitincluding earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for air conditioner , wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. , sb. 8.28supplying with fitting fixing of 6 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including installation of socket outlet 6 / 16 amps 3 / 5 pin combine shuttered complete , including making necessary connection as per direction of department. , supplying with fitting fixing of 10 / 16 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including and fixing of following moulded pvc boxes for in surface system complete as per direction of department. 8 module surface moulded pvc boxes. , supplying including fitting fixing of following front plate of suitable colour as per direction of department. 8 module , supplying including and fixing of following moulded pvc boxes in surface system complete as per direction of department. 12 module horizontal surface moulded pvc boxes , supplying including fitting fixing of followingfront plate of suitable colour as per direction of department. 12 module , supplying with installation testing and commissioning of hi wall 4 star rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the deptt. ) up to 5 m between the room unit and out door unit as directed by the department. 2 ton capacity r410 , supplying with fitting and fixingvoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 5.0 kva automatic input 120 280 v out put 200 240 v , supplying with fitting and fixing of angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 ton to 2.00 ton window / split type a.c. machine , supplying with fitting and fixing of single phase modular a.c starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. , supplying including fitting fixing of followinga.c. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department [ without regulator ] . premium model1400 mm sweep. , supplying with fitting and fixing of 120 watt electronic modular step speed control 2 module type including making necessary connection as per direction of department. 120 watt electronic modular step speed control2 module type , supplying with fitting and fixing panel mounting open execution 35 / 36ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure ) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35 / 36 ka 415v 50 hz 3p mccb 400a , supplying with fitting and fixing panel mounting open execution 25 ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure of the following capacity complete with making necessary connection as approved by the deptt. as specified and directed by the deptt. 25 ka 415v 50 hz 3p mccb 125a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 100a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 63a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.c series 6 to 32a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.b series 6 to 32a , cc camera , public adress system , view box , supplying with fitting and fixing of 12watt, round led ceiling light with frame , supplying including fitting fixing of followinga.c. exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department. heavy duty 450 mm sweep 900 rpm single phase , d ) furniture works , suppying and installation of coloured tv 22 flat led wall mountingas directed by the department. , supplying fitting and fixing of furniture rack, table, store almirah, revolving chair etc. as required. , a ) computer chair ( 6 nos for control console & 6 nos. for tps room ) , b ) master table for use in computer in control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 10 x 3x2.5 ) ( 1 no for control console & 1 no. for tps room ) , c ) wall mounting manual shelf control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 6x2x16 ) , d ) shelf inside the labunkermade of best quality water proof green ply 18mm thick finishing with sunmika size ( 8 x 6x2 ) , e ) sypplying of decorative & comfortable 3 seater patient waiting chairmust be approved by the department. , cat ( b ) buy back items , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at actrec kharghar , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at tmh mumbai...

Indian Oil Corporation Limited - Maharashtra

31941632 tender for design, engineering, supply, installation, testing and commissioning of complete emergency shut down ( esd ) system, dyke valve monitoring system ( dvms ) , and lighting distribution panel ( ldb ) at lc trombay => limited...

Bhabha Atomic Research Centre - Maharashtra

31912485 tender for painting of electrical control panels. d.bs. and power distribution panels and supply. installation and testing of m.s enclosure of power panel at afd....

Bhabha Atomic Research Centre - Maharashtra

31830837 preventive maintenance, testing and installation of field instruments and associated hardware 1. on site testing and calibration of pressure transmitter 2. on site testing and calibration of level transmitter (twice in a year) 3. preventive maintenance of gas distribution panel rotameter & pneumatic tubing (twice in a year) 4. on site installation of electromagnetic flowmeter at umrt...

Airports Authority Of India - Maharashtra

31653043 bids are invited for outdoor ptz camera , indoor ptz camera , outdoor fixed camera , indoor fixed camera , outdoor fixed anpr camera , layer 3 switch , layer 2 switch , wi max base transceiver station bts , wi max element management system ems , wi max customer permices equipment cpe , network attached storage nas , camera server , ntp server , workstation , video wall displays , workstation displays , speed dome contoller joystick , kvm switch , laser printer , online ups , equipment rack 40 42u , equipment rack 9u , equipment rack 3u , power distribution panels , console for control room , vms and digital videosurveillance control software , video analytics softwarelicense maximum 50 cameras , 25mm 16 swg ms conduit ,50 mm dia hdpe pipe , 80 mm gi pipe , ofc cable 6 core ,cat 6 stp data cable , 3 core 2.5 sqmm power cable , 3core 1.5 sqmm power cable , rj 45 termination box , 12port light guide interconnect unit liu , 6 port light guideinterconnect unit liu , media converter , gi pole , earthing ,excavation preferably with horizontal drilling , excavationwithout horizontal drilling , road cutting , traning ,documentationsitc of scctv system at aurangabad airport with 3 years total quantity : 27764...

Maharashtra Industrial Development Corporation - Maharashtra

31434315 name of work : ambernath e&m...m&r to wss for shahad ... replacement of l.t distribution panel at stage i , stage ii & stage iii filter house & providing advanced early streamer emission (ese) lightening protection system at wtp & jackwell....

Central Public Works Department - Maharashtra

31347535 maintenance of electrical installation and fans r / m of water supply pump set, s / stn, equipment, comp. mtce. of ac units and external services in msme bldg., sakinaka, mumbai. 2 supplying, installation, testing and commissioning of ip based cctv camera system along with all accessories such as nvr, various types of cameras, hard disk, ups, racks, poe switch, led display cabling etc at msme office bldg sakinaka, mumbai. 3 supplying installation testing and commissioning of lt distribution panel along with 200 kvr apfc panel i / c lt cabling etc. at msme office bldg., sakinaka, mumbai. sh : providing speakers, ups and air purifier....

Western Coalfields Limited - Maharashtra

30808624 fabrication and erection of 16 nos. of lt distribution panels for power supply to different blocks of quarters at kailashnagar colony , mungoli sub area ...

Central Railway - Maharashtra

30796875 auction sale of scrap 2200 volts / 415 volts sub station equipments consisting of a ) 500 kva transformer ht 3 phase brush make = 01 no. b ) 500 kva transformer ht 3 phase kirloskar make = 02 nos. c ) ece make 2200 volt, 400 amp feeder ht panel and bus coupler including oil circuit breaker and switchgear = 07 nos. d ) 440 volt, 800 amp lt feeder / distribution panel and bus coupler = 10 nos. and mineral oil = 635 kgs. remarks approach road is available approx. 50 mtrs. away from the lot. delivery will be given on lot basis. delivery will be made during all seasons. cutting is allowed if required for easy loading delivery. cables and other attachments under ground / cable trench will not be delivered. purchaser will bring his own crane / labour for loading scrap items. purchaser has to ensure safety of railways assets and his labour while working in railway premises. if any losses arise due to negligence, the purchaser will fully be responsible for the same. purchaser is advised to see the lot, site and loading point before bidding. location sse ( mill wright ) section at els kyn. qty 01 by lot. stock holder sse ( mw / els ) kyn. origanal lot no. 035121126107....