Water Resources Department - Maharashtra

39766905 mechanical components for rehabilitation of jayakwadi project in tq. paithan dist aurangabad of maharashtra ( under drip ii ) 2 dam work jayakwadi projectrepairs 3 replacement of bend and twisted tie channels 4 nos 4 restoring alignment of gear train no 2 ,3,7 and 9 for gate no.4 5 repairs to goliath crane at spillway with painting by synthetic enamel paint@ jayakwadi project 6 restoration of component of stoplog girder resting arrangement 7 fabrication of stoplog gate assembly complete 1 no of size 12.192x1.0 mtr with skin plate, web plate, flange plates, stiffeners, roller assys 4 nos etcfor jayakwadi project 8 fabricationand erection stop log repairplatformof size17.5 x 2.7 mtr at jayakwadi project 9 repairsand maintenance of goliath crane @ chanakwadi barrage 10 manufacturing, and erection of hoist protection cabin and extended platformat lbc and rbcat jayakwadi project 11 providing ,erecting, testing and commissioning offorward reverse starter upto 20hp gate motor(inductionmotor ) 12 providing ,erecting, testing and commissioning ofinductionmotor for gate upto capacity 15 hp 13 supply and erecting mains with 2 x 2.5 sq.mm fr copper pvc insulated wire laidin provided conduit/ trucking/ inside pole/ bus bar or any other places as per specification no wg ma/bw 14 supplying and erecting mains with 3 x 10sq.mm fr copper pvc insulated wire laidin provided conduit/ trucking/ inside pole/ bus bar or any other places as per specification no wg ma/bw 15 supplying and erecting triple pole metal clad hrc fuse switch 415 v ,63 a with neutral link with hrc fuses on angle iron /giframe as per specification sw swr/tphrc 16 supplying erecting and marking tpn mcb 40a to 63a,c series in provided distribution board as per specification no sw swr/mcb 17 supplying and erecting crcasheet metal one way enclosures suitable for dpmcb/ tpmcb / fb mcb erected on angle iron gi frame 18 supplying and erecting gi sheet 1.6 mm (16 swg) to be used for fabrication of boxes panel boards etc including cutting, bending drilling, welding ,riveting etc and paintingwith one coat of red lead paint and 2 coats of enamel paints 19 supplying and erecting iron ,sheet metal work consisting of crcasheets ,various section of iron ,plates, checker plates, rods, bars ,ms pipes etc for panel board or any other purpose with bending ,cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two quotes of enamel paints to match the switch gears or as per direction by the authority 20 supplying and erecting panel mounting type digital ammeter having three and half digit led display, external ct operated, calibrated for suitable to operate on 500 v, 0 to 1000aac supply with necessary pvc wire leads and lugsand mounting hardware on provided panel complete with calibration certificate from manufacturer 21 supplying and erecting panel mounting type digital ammeter having three and half digit led display, calibratedfor 0 to 750v ac suitable to operate on 500v ac supply with necessary pvc wire leads and lugsand mounting hardware on provided panel complete with calibration certificate from manufacturer 22 supplying and erecting selector switch suitable for voltmeter /ammeter for three phase ac supply 500v,50 hz ,on provided box, panel and duly connecting with necessary pvc wire leads and lugs. 23 supplying and erecting lt current transformer with bar primary 50/5 to 1000/5ratio with 15 vaburden erected in provided crca box duly secured with insulating material connected to the meter with test certificate 24 supplying and erecting 525 v3 phase, 50 hz ,app type capacitor having minimum over current capacity of 1.8in, peak in rush current capacity 300i n and minimum life 150000 hour kvar bank of all poly propylene condenser (app)with the standard capacities of 2,3 ,5,7 ,10 ,12.5 and 15 kva runits of p.f correction for operation on 3 phase 50hz with externally discharging resistance ,earthingterminals and build on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. 25 supplying and erecting set of 3 pilot lamps all bakelite with colour glasses with miniature lamps 230 v /250v erected on provided crca box with panel type fuses and connected with pvc wires 26 supplying erecting and terminating xlpe armoredcable 3 core 25 sqmm aluminum conductor with continuous 5.48 sq mm gi earth wire complete erected with glands and lugs, on wall /trusses/ pole or laid in provided trench/ pipe as per specification no cb lt/al 27 supplyingand erecting crimping type aluminum lugs for cable 25 sq.mm complete as per specification no cb cl/al ...

Hydro Electirc Project - Maharashtra

39681377 electrical components for rehabilitation of jayakawadi dam, paithan dist. aurangabad 2 sub estimate a : supply, erection, testing & commissioning of transformer & panel at jayakwadi dam 3 item no 1 :supplying, installing, testing & commissioning of 3 phase, 11/0.433 kv, 50 hz., 100 kva, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oc by thermometer in oil and 45oc by the resistance in winding at full load rating, with hv tapping (with off load tap changer) off load +5 to 10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 475 watts at 50% load, 1650watts at 100% load as per is:1180 2014 energy efficiency level ii, with necessary permissions of electrical inspector, as per specification no ss tr. 4 item no 2 :supplying & erecting end pole d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos.100 amps kitkat/mccb for outgoingcircuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. top channel of size 100 mm x 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 x mm for erecting transformer. channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. vee cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected inc.c. foundation complete. 5 item no3 :providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. eaep 6 item no 4: supplying, erecting & terminating xlpe armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq.mm. (8 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 7 item no 5: supplying and erecting four pole metal clad on load change over switch 415 v, 400a erected on angle iron / gi frame complete. 8 item no 6:providing & erecting 3 pole mccb of 315/400a, 415v capacity with short circuit rating 36 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure on iron /gi frame as per specification no. sw swr/mccb 9 item no 7:supplying and erecting lt ct multifunction dlms compliance energy meter of accuracy of class 0.5 , 3x240v,50 hz with optical & rs 232 port, backlit lcd, measures & displays trivector energy, load survey, tod, tamper detection & logging, power on /off events, instantaneous parameters of rating 1/5 a with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided m.s. box and connected to cts 10 item no 8:supplying and erecting lt current transformer with bar primary 50/5 to 1000/5 ratio with 15 va burden erected in provided crca box duly secured with insulating materialsconnected to the meter with test certificates. 11 item no 9: supplying, erecting & terminating xlpe armoured cable 1100 v. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb lt/all 12 item no 10 :providing & erecting 3 pole mccb of 200a,415v capacity with short circuit rating 25 ka (ics=100% of icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads,provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosureon iron /gi frame as per specification no. sw wr/mccb 13 item no 11 :providing & erecting 3 pole mccb upto 100a, 415v, with short circuit rating 25 ka (ics=100% of icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosureon iron /gi frame as per specification no. sw wr/mccb 14 item no 12 :supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500v 400a complete as per specification no.cp bb 15 item no 13 :supplying & erecting led type indicating pilot lamp with led colours red / yellow / green, 230 / 250v on provided box / panel with necessary material, wiring & connections etc. 16 item no 14 :supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. 17 item no 15 :making trench of suitable width and depth in soft soil for laying provided lt cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. cw exnctr 18 item no 16 :supplying & erecting mains with 4x25 sq.mm f.r copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/bw 19 item no 17 :supplying & erecting mains with 4x50 sq.mm fr copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/bw 20 item no 18: supplying and erecting terminal spreaders for use on mccb incoming and outgoing terminals for 3 pole upto 100a mccb complete. (set of 6). 21 item no 19: supplying and erecting terminal spreaders for use on mccb incoming and outgoing terminals for 3 pole upto 250a mccb complete. (set of 6) 22 item no 20:supplying and erecting terminal spreaders for use on mccb incoming and outgoing terminals for 3 pole 300a 400amccb complete. (set of 6) 23 item no 21:supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. 24 item no 22 :supplying and erecting g.i. stay set for poles, includingloop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7/10 swg, g.l. stay rod 20 mm x 1.8 m length andpole clamps duly erected in provided cement concrete foundation. 25 item no 23: dismantling existing pole mounted distribution transformer safely without any damages. 26 item no 24: dismantling existing do / ab switch set complete from d.p. structure in an approved manner. 27 item no 25: dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 28 item no 26: dismantling existing lightning arrestor set, insulator complete from dp structure in an approved manner. 29 item no 27: dismantling the existing cables of all types & size above 50 sq. mm. 30 item no 28:dismantling the existing switchgears, db, and bus bar of any size complete with/ without board or angle iron frame complete. 31 supply, erection , testing & comissioning of cables &control panel at inspection gallary at jayakwadi dam 32 item no 29:making trench of suitable width and depth in soft soil for laying provided lt cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. cw exnctr 33 item no 30: supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as perspecification no. cb lt/al 34 item no 31:supplying and erecting four pole metal clad on load change over switch 415v, 200a erected on angle iron /gi frame approved make complete. 35 item no 32 : providing & erecting 3 pole mccb of 200a,415v capacity with short circuit rating 25 ka (ics=100% of icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure on iron /gi frame as per specification no. sw swr/mccb 36 item no 33: providing & erecting 3 pole mccb upto 100a, 415v, with short circuit rating 25 ka (ics=100% of icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure on iron /gi frame as per specification no. sw wr/mccb 37 item no 34:supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 v with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. bcp bb 38 item no 35:supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. 39 item no 36: supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. cb lt/al 40 item no 37 : supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 41 item no 38 : supplying & erecting original 1.25 mm crca sheet metal enclosures with 30a, 3 pin plug & earth socket and 30 a 3 pin plug top with 30a triple pole mcb complete erected on angle iron/ gi frame 42 item no 39 :supplying and erecting led street light fitting suitable above 26w to 36w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fgodf/fls2. 43 item no 40 : supplying, erecting & marking spmcb 0.5a to 5a in provided distribution board as per specification no. sw swr/mcb 44 item no 41 :supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb 45 item no 42: supplying & erecting mains with 2x1.5 sq.mm f.r copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per 46 item no 43:dismantling the existing cables of all types & size above 50 sq. mm. 47 item no 44: dismantling the existing cables of all types & size up to 10 sq. mm. 48 item no 45: dismantling the existing switchgears, db, and bus bar of any size complete with/ without board or angle iron frame complete. 49 item no 46: dismantling the existing underground cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete. 50 supply, erection, testing & commissioningof making electrical supply arrangement for the gate operationat jayakwadi dam 51 item no 47: supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. cb lt/al 52 item no 48: supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. cb lt/al 53 item no 49:supplying, erecting & terminating xple armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 54 item no 50:providing & erecting 3 pole mccb upto 100a, 415v, with short circuit rating 25 ka (ics=100% of icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure on iron /gi frame as per specification no. sw wr/mccb 55 item no 51:supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. 56 item no 52: supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 v with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as perspecification no. bcp bb 57 item no 53: supplying and erecting led flood light fitting of 90 100w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fg df/fls 2 58 item no 54 :supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no . fg odf/fls2 59 item no 55 : supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb 60 item no 56 : supplying, erecting & marking spmcb 0.5a to 5a in provided distribution board as per specification no. sw swr/mcb 61 item no 57 :supplying & erecting mains with 2x1.5 sq.mm f.r copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/bw 62 item no 58 :supplying & erecting mains with 2x2.5 sq.mm f.r copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/bw 63 item no 59 :supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. cb lt/al 64 item no 60 :supplying, installing, testing and commissioning solar street light pole comprising of 12w led luminaire, 12.8v 30ah li battery, with 75wp solar panel, ms powder coated battery box weatherproof, mounted on 75/80 mm dia. bgrade gi pole of 6 mtr. height (5m above ground & 1m below ground), 12w led chip of luminaire should be in compliance to ies: lm 80 & performance parameters of luminaire shall be as per ies lm 79:2008 or is 16106 : 2012); along with brackets, foundation, earthing and necessaryaccessories complete as per mnre specification (with 5 years warrantee) 65 item no 61 :supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no. sw swr/mcb 66 item no 62 : supplying, erecting and marking enclosure single pole and neutral distribution board (spndb) one pole for spmcb 1 no on iron/ gi frame as per specification no. swswr/mcbdb 67 item no 63: point wiring in pcc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw/ sw 68 item no 64: wiring for plug on board with switch socket, copper wiring and earthing as per specification no: wg pw/sw 69 item no 65: supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm frlsh pcc copper wire in hms pcc conduitmin. 20mm dia. as per specification no: wg ma/pc. 70 item no 66: supplying, erecting & terminating xlpe armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq.mm. (12 swg) g.i. earth wire complete erected with glands& lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu 71 item no 67 : supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf 72 item no 68 : supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. 73 item no 69 :supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and =e‘ class insulation. 74 item no 70 :supplying & erecting led 18w tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated hf electronic driver complete. 75 item no 71:supplying & erecting 18w, 230v integral type led lamp suitable for b 22/e 27 base. 76 item no 72 :providing & erecting hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) gi sheet of 500 mm width & 20 mm height complete with necessary hardware in approved manner. 77 item no73 :providing & erecting hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. 78 item no74 : providing floor mounting stand for keeping 4 nos. of fire buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. 79 item no75 : providing round bottom fire bucket of 9 litres capacity as per is :2546 made out of 24 gauge g.i. sheet with extra handle at bottom duly painted white inside and red outside with fire mark, on provided stand/ wall hook complete. 80 item no76 : providing pair of duly tested rubber hand gloves as per is :47705 suitable for working upto 22 kv supply complete. 81 item no77:supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (band aid) adhesive tape for medicinal use, scissors, anti septic solution, etc. (all above contents shall be of standard makes) 82 item no78 :supplying shock proof leather safety shoes of electrical grade of standard size as is :11226, 14544 duly tested, with necessary test certificate from manufacturer. 83 item no79 :supplying and erecting d.c.p. type fire extinguisher 9 kg capacity cartridge type with gun metal cap 150 gram co2 gas cartridge, powder and brackets conforming to is 2171 1985 and complete erected with necessary clamps made from 50x6 mm m.s. flat with nuts & bolts grouted in wall complete. 84 item no 80: supplying and erecting abc powder type fire extinguisher as per is : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. 85 item no 81: supplying and fixing pcc synthetic elastomer electrically insulating mat with class b insulation conforming to is: 15652 – 2006 & cpri tested having 2.5 mm thickness upto 11 kv 86 item no 82: supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 87 item no 83: sitc of 415 volts, 3 phase, 50 hz siren of 8 km range, horizontal double mounting type of 5 h.p. 2800 rpm on c.c. foundation complete as per specification no. srn as/sm 88 item no 84: supplying and erecting flat flexible 3 core 4 sq mm pcc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 89 item no 85:early streamer lightening arrestor: sttc of advanced streamer emmision (ese) type of lightening arrestor of covering a radious of 125 meter, when mounted at a height of 5 meter above terrace floor leve, having triggering time 63 micron second, totally atonomous device, designed to work on positively as well as negatively charged cloud condition, internal triggering circuitry & electronics should contain ambient electric field sensor, charge accumulator, command & hv amplifier, transformer & triggering release. it is designed as per nfc17 32 & iec 60 1:1989. ese ternimal should be tested by cpri for the impulse current of 40ka (8/20 micro sec) with 5 positive & 5 negative impulse with folllowing specifications of capacity 200 ka (3/35 micro second ), capacity against wind speed 40m/s, dimension 39cm, lower diameter of ese should be 30.5 cm, weight=4 kg, the ese lightening arrestor should be should be tested in msme devlopment institute, along with of 6 digit transient event counter with display digit from 0 to 999999 for a minimum count impulse greater than 1ka (8/20 micro sec) with degree of protection ip 20 with 3 earthing electrodes of 3 meter length in grid, with high mast pipe cooecting link &including with all required accesorries. 90 item no 86:supplying and erecting isi mark gi pipe 75/80 mm dia. „b? class at position with accessories complete. specification no. cw plb/gp. 91 item no 87: supplying and fixing ms base plate 30x30x0.6 cm size fixed to the pole base either by welding or by set screws 12 mm. dia fixed at position. 92 item no 88:supplying, erecting & terminating xlpe unarmoured cable 1 core 70 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel/distribution boards / pipe as per specification no. cb lt/cu 93 item no 89:dismantling the existing cables of all types & size above 10 sq mm up to 50 sq. mm. 94 item no 90:dismantling the existing cables of all types & size above 50 sq. mm. 95 item no 91:dismantling the existing switchgears, db, and bus bar of any size complete with/ without board or angle iron frame complete. 96 supply, erection, testing & commissioningof street light at jayakwadi dam 97 item no 92:supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per specification no. sw swr/mfp 98 item no 93:supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 99 item no 94:supplying, erecting & terminating xlpe armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 100 item no 95:supplying, erecting & terminating xlpe armoured cable 3½core 70 sq. mm. aluminium conductor with continuous8.35 sq. mm. (10 swg) g.i. earth wire complete erected withglands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 101 item no 96:supplying, erecting & marking spmcb 0.5a to 5a in provided distribution board as per specification no. sw swr/mcb 102 item no 97:supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no.cb sb 103 item no 98:supplying & erecting mains with 2x2.5 sq.mm frlsh copper pcc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/ bw 104 item no 99:supplying, erecting & terminating xple armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al 105 item no 100: supplying and erecting led street light fitting suitable for above 70w 75w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fgodf/ fls2 106 item no 101: providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. eaep 107 item no 102: supplying and erecting 12.5 m (clear height) high mast (top 150mm, bottom 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no. oh pl/hm (excluding luminaries ). 108 item no 103: making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). 109 item no 104: supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fgodf/fls 2 110 item no 105: supplying and erecting outdoor stand mounted feeder pillar for highmast of the same manufacturer with 32a tpn mcb incomer, single dial timer switch, 25a tp contactor for automatic switching of luminaries, 2 nos 9a contactors andraise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected with cc foundation complete.note: rates are inclusive of foundation. 111 item no 106: supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. 112 item no 107:painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. specification no cw ptg/ptp. 113 item no 108:dismantling the existing cables of all types & size above 10 sq mm up to 50 sq. mm. 114 on grid solar power pack 115 item no 109:supplying, installing, testing and commissioning of 20 kwp capacity on grid solar power pack with gi mounting structure and inter connecting wires / cables without battery bank spv modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. specification no. esd rt ong note: 2. for item no.4 6 2 add rs. 39657/ per kwp for on grid solar power pack above 11 kwp upto 100 kwp. 116 item no 110 :supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 117 item no 111 :supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. swswr/mcb 118 item no 112: supplying and erecting three phase 10 to 60 a net meter dlms compliance of accuracy class 1.0, 3 x 240v, 50 hz, with backlit lcd display, optical port and rj 232 port (measures import kwh, kvah, export kwh, kvah, net kwh, kvah,v, i, kw, 6 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. 119 item no 113: supplying and erecting three phase smart energy meter dlms compliance with 3x240v 50 cycles ac supply 10 60 a, isi mark, accuracy class 1.0 with backlit lcd display, measuring & display v, i, kw, kwh, pf, kva, kvar, md, day, week, month & with communication module configurable for gsm/wi fi, irda/bluetooth, complete provided panel with calibration certificate from manufacturer & duly wired with required size of pcc wires. 120 item no 114: charges for taking permission from various authority such as msedcl or else. ( it will be reimbursed only after submission of original reciepts by the contractor to this department.) 121 part b 122 sub estimate b:electrification of irb guest house at paithan,dist.chatrapati sambhajina gar. 123 item no 115: point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw 124 item no 116 :point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw 125 item no 117 :secondary point wiring for additional light/ bell point in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire with required accessories as per specification no: wg pw/sw 126 item no 118 :point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw 127 item no 119: wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no: wgpw/cw 128 item no 120: supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete 129 item no 121: supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 130 item no 122:supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete 131 item no 123:supplying and erecting modular type switch 16 / 20 a with indicator, duly erected on provided plate and box with wiring connections complete 132 item no 124:supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 20a, 2 pin plug & earth socket and 20a, 3 pin plug top with 20a/30a single pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron/ gi frame. 133 item no 125:supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete. 134 item no 126:supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 135 item no 127:supplying and erecting pvc surface modular switch box with doublemounting plate for 12 module duly erected 136 item no 128:supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected. 137 item no 129:supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected 138 item no 130:supplying and erecting pvc surface modular switch box with doublemounting plate for 2 module duly erected. 139 item no 131 :supplying and erecting modular type blanking plate one module, duly erectedon provided plate & box 140 item no 132: supplying and erecting led square / circular max. 7w down lighter/ panellight having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty 141 item no 133: supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. 142 item no 134 :supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base 143 item no 135 :supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. 144 item no 136:supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200mm complete erected in position as per specification no. fg fn/cf 145 item no 137:supplying and erecting fan clamp of 30 x 5 mm. m.s. flat of required length and 10 mm. m.s. bolt and nuts erected with necessary hook of 10 mm. m.s. round bar and painted. 146 item no 138:supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as perspecifcation no. fg fn/exf 147 item no 139:supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 148 item no 140:supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1tr to 2.3tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac 149 item no 141:supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as perspecification no. ap inv 150 item no 142:supplying and erecting 12v/200ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete 151 item no 143:supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw 152 item no 144:supplying and erecting mains with 1x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw 153 item no 145:supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw 154 item no 146:supplying and erecting mains with 1x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw 155 item no 147: supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit/ trunking/ inside pole/ bus bars or any other places. as per specification no: wgma/ bw 156 item no 148 : supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. 157 item no 149 : supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 158 item no 150 : supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb 159 item no 151 :supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as perspecification no. sw rccb/rccb 160 item no 152 : supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no. sw swr/mcb 161 item no 153: supplying, erecting & marking spmcb 6a to 32a, c series (for motor/power) in provided distribution board as per specification no. sw swr/mcb 162 item no 154: supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb 163 item no 155:supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb 164 item no 156:supplying, erecting & marking tpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specificationno. sw swr/mcb 165 item no 157: supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb 166 item no 158: supplying and erecting blanking plate of suitable size on mcbdb 167 item no 159: supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 168 item no 160: supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 169 item no 161: supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 170 item no 162:providing & erecting 4pole mccb, 415 v, 100a, rated short circuit breakingcapacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixedmagnetic setting with provided leads, provision for installation of shunt/uv/tripalarm contact. mccb with phase barriers on both sides, insulation withstandcapacity 800v, no line load bias in provided enclosure/panel as per specificationno. sw swr/mccb 171 item no 163:dismantling the existing light, fan, bell, clock, independent plug point,wiring including circuit mains of all types along with accessories etc.complete as per specification no: wg dm/pw 172 item no 164: dismantling the existing aluminium/copper mains, sub mains wiringupto 10 sq.mm. along with accessories etc. complete as per specification no:wg dm/pw 173 item no 165: dismantling the existing w.t. fluorescent fitting / s.v./ m.v. / m.h. lamp/led fitting from wall with brackets and making the site as original complete. 174 item no 166:dismantling the existing ceiling fan /exhaust fan / cabin fan / bracket fancomplete with accessories, g.i. down rod, frame etc. and making the site clear 175 item no 167:dismantling the existing switchgears, db, and bus bar of any size complete with/ without board or angle iron frame complete. 176 item no 168: making the site clear of dismantled db and switch gears by refilling the holes with cement mortar & finishing in an approved manner complete. 177 item no 169:providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no.ea ep 178 item no 170:supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the resultsspecification no. ea mobi 179 item no 171 : supplying and erecting gi wire of high purity of required sizes used for earthingor any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete.. 180 item no 172 : providing & erecting 9 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl 181 item no 173:supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2 182 item no 174:making cement concrete foundation including excavation (60 x 60 x 150) cmeep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 183 item no 175:supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al 184 item no 176 : supplying and erecting street light bracket for erection of single fitting madefrom 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300mm length 100 mm dia duly welded as per specification no. fg bkt/bpc 185 item no 177 : dismantling the existing pole above 6 m height with brackets, clamps,insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 186 item no 178: supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. 187 item no 179: providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no.ea ep 188 item no 180 : supplying and erecting integrated led street light fitting 26 to 30w ip65 ik08 class having single piece pressure die cast aluminium housing , havingsystem lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w,cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v,inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. 189 item no 181 :supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. 190 item no 182 :supplying and erecting ultra violet storage type water purifier (ro+uv+uf)with softener for safe drinking water consisting of uv germicidal tube of 8wcapacity choke made of copper wire and two indicator lamps with output ofpurified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter changeindication system .(for tds more than 200) 191 item no 183: supplying, erecting, testing and commissioning self contained water cooler230/250v 50hz nominal cooling capacity of 150 litres per hour and storagecapacity 150 litres with partially stainless steel body as per specification no. apwcr/wc 192 item no 184: supplying and erecting storage type water heater 25 litres capacity havingstanding loss <0.511kwh/24hour/45°c, high impact resistance engineeringplastic body with anti corrosive high grade steel inner tank, heatingelement having hard water & corrosion protection, with minimum 3 safetyprotections (i.e. thermostat & thermal function cut out, valve) with totalpressure 8 bar withstanding capacity duly tested and marking sr. no. and date of 193 item no 185: supplying double door refrigerator domes tic type of 300 to 360 litres storagecapacity, minimum 5 star inverter type, stabilizer free operation suitable foroperation on 100v/300 v, 50hz with automatic temperature con trol, shall bemarked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete 194 item no 186:supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ...

South Central Railway - Maharashtra

39614101 supply of come along clamps for earth wire 19 / 2.5 mm galvanized steel capcity 2.5tonne with load test certified from gov. approved laboratory, make: srec, pce, sste or similar. [ warranty period: 30 months after the date of delivery ] ...

Directorate Of Municipal Administration - Maharashtra

39593035 supplying and erecting electrical accessories, switch gear, cables etc for year 2023 24 1 pvc copper wire 1 sqmm ( 90m ) 2 pvc copper wire 1.5 sqmm ( 90m ) 3 pvc copper wire 2.5 sqmm ( 90m ) 4 twin core pvc to pvc aluminium service wire 6 sqmm ( 90 ) 5 insulation tape ¾”, 10 mtr 6 icdp main 32 a. 230 v 7 dp switch 32 a, 230 v 8 pianno switch 5 amp 9 socket 5 amp 10 bell push 5amp 11 fan regulator socket type 12 pendent holder 13 batten holder 14 modular switch 5 amp 15 modular socket 5amp 16 modular combined switch socket 16 amp 17 modular switch 15 amp 18 modular socket 15 amp 19 3 pin top 6amp 20 3 pin top 15 amp 21 ding dong bell 22 electronics cordless bell 23 flexible wire 40 x 36 24 porceleian cutout 100 amp 25 screw driver 9 “ 26 insulated piller 8” 27 4 x 25 sqmm pvc armoured cable 28 line tea ster 29 4 pole contractor 45 amp 30 timer 31 mcb 6a to 32 amp 32 supplying submersible pump 2 hp 33 pvc switch box 4 module 34 pvc switch box 8 module 35 casing capping patti 36 led tube light 20 watt 37 led flood light 200 watt 38 led street light 60 watt 39 led fitting driver 10 kva protection 40 exaust fan15 “ heavy duty 41 exaust fan 8 “ 42 ceiling fan56” 43 ceiling fan48” 44 capacitor 2.25 mfd 45 pedestalfan air circulator 450 mm sweep heavy duty 46 wire less telephone instrument gsm based. 47 wall mounted fan 450 mm sweep 48 4 core 120 sqmm armoured cable 49 led bulb 7 watts 50 led bulb 15 watts 51 led panel light15 watts 52 telephone instrument 53 4 polemcb 63 amp 54 aluminium ladder ( ghoda ) 10 feet 55 erecting pvc insulated pvc round sheathed 2.5sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 56 led panel light 2ft x 2ft 57 supplying and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 rpm without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230 / 250 volts single phase, 50 cycles a.c. supply, core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. 58 point wiring in pvc trunking ( casing capping ) with 1.5sq.mm ( 2+1e ) frlsh grade copper wire, flush type switch, earthing and required accessories 59 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories 60 wiring for plug on board with switch socket, copper wiringand earthing 61 supplying and erecting pvc surface modular double mounting plate 4 modules complete duly erected. 62 supplying and erecting pvc surface modular doublemounting plate 8 modules complete duly erected. 63 supplying and erecting pvc surface modular doublemounting plate 12 modules complete duly erected. 64 supplying and erecting pvc surface modular double mounting plate 16 / 18 module complete duly erected. 65 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 66 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 67 supplying & erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places 68 supplying & erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. 69 supplying & erecting mains with 2x6 sq.mm frlsh copperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. 70 supplying & erecting mains with 2x10 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places 71 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 72 supplying and erecting pvc insulated pvc round sheathed 2.5sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 73 supplying and erecting mains with isi mark wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected 74 supplying and erecting isi mark modular type switch 6a / 10aduly erected on provided plate and box with wiring connections complete. 75 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 76 supplying 6 amp. 3 pin plug top bakelite type of 230 v. a.c. supply. 77 supplying 16 amp. 3 pin plug top bakelite type of 230 v. a.c. supply. 78 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 79 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 80 supplying, erecting & terminating xlpe armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe. 81 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq.mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 82 supplying, erecting & terminating xlpe armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 83 supplying, erecting & terminating xple armoured cable 4 core 16sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 84 supplying, erecting & terminating xlpe armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 85 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 86 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results 87 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 88 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 89 supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e 27 base. 90 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 91 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wiremesh, duly erected in an approved manner. 92 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position 93 supplying and erecting regular / standard model ceiling fan of 600mm. sweep complete erected in position 94 supplying and erecting regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position as per specification no. fg fn / cf 95 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 96 providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm without speed regulator, overheatprotection unit, totally enclosed, flame proof motor suitable for230 / 250 volts single phase, 50 cycles a.c. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘e’ class 97 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wiremesh, duly erected in an approved manner. 98 supplying and erecting electronic type step regulator for ceiling fan 600 / 900 / 1200 / 1400 mm. sweep, complete erected on provided switch board. 99 supplying and erecting ultra violet storage type water purifier ( ro+uv+uf ) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water 7 to 8 litre / min with activated carbon filter and softener operating on 230 v single phase a.c. supply. 100 supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 2 litre / min. with activated carbon filter and softener operating on 230 v single phase ac supply. 101 supplying and erecting isi mark midget type 3.0 ltr storage type water heater of abs plastic body 3 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 102 supplying and erecting isi mark midget type 10.0 ltr storage type water heater of abs plastic body 5 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 103 supplying and erecting isi mark midget type 1.0 ltr instand type water heater of abs plastic body 1 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 104 supplying, installing, testing and commissioning split type variable speed inverter technology room air conditioning unit 1.5 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hiwall / floor mounting type complete with refrigerant r410 a / r32 and copper condenser at position 105 supplying, installing, testing and commissioning split type variable speed inverter technology room airconditioning unit 1 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hi wall mounting type complete with refrigerant r410a / r32 and copper ondenser at position. 106 supplying, installing, testing and commissioning split type variable speed inverter technology room air conditioning unit 2 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hi wall / floor mounting type complete with refrigerants r410 a / r32 and copper condenser at position 107 supplying, erecting & marking spmcb 6a to 32a, c series ( for motor / power ) 108 supplying, erecting & marking dpmcb 40a to 63a, c series ( for motor / power ) in provided distribution board 109 supplying & erecting original 1.25 mm crca sheet metalenclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete 110 spike guard protector 4 switch 4 socket 111 supplying, fixing and commissioningchange overswitch 4 pole, 100 a 112 supplying, fixing and commissioningchange overswitch 4 pole, 200 a 113 supplying and installing water dispenser having hot / cold cabinet both facility, floor mounted. 114 supplying & erecting condenser 2.25 mfd 115 supplying & erectingbulb holder. 116 supplying and erecting pvc trunking ( pvc casing n capping ) of size 25 mm with accessories on wall / ceiling 117 supplying, installing, testing and commissioning window model mounted type room air conditioner having iseer minimum 3.1 to maximum 3.29 suitable to operate on 230 / 250 v 50 cycles single phase a.c.supply 1.5 tr capacity with refrigerant r410a / r32 and copper 118 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint 119 supplying and erecting isi mark g.i. pipe pole ‘b’ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation 120 supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation 121 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 122 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 123 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 124 providing & erecting 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70mm a / f 125 providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70mm a / f 126 providing & erecting 8 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 135 mm a / f, top 70mm a / f on provided foundation 127 providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70mm a / f on provided foundation 128 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball 129 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball 130 supplying and erecting outdoor stand mounted feeder pillar for highmast of the same manufacturer with 32a tpn mcb incomer, single dial timer switch, 25a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, andprovision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected with cc foundation complete. 131 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials 132 supplying and erecting street light wall bracket made from 40 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete 133 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugatedpipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 134 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 40 a, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the maximum load of 6 kw on provided iron frame / cc foundation complete. 135 making cement concrete foundation including excavation ( 45 x 45x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( for 6 m pole ) 136 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 3 to 5m octagonal / conical gi pole ) . 137 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 138 making m 20 grade reinforced cement concrete foundation byconsidering the safe soil bearing capacity at site as 10 t / sq.m at 1.5m depth including supply of steel, concrete, excavation and fixingprovided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 139 making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 12.5 m raising lowering high mast ) . 140 painting of pipe pole upto 6 m length along with street light / pole brackets / clamps etc by scrapping the existing paint complete. 141 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping theexisting paint complete. 142 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 143 rewinding motor of the 1200 / 1400 mm ceiling fan and overhauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption with guarantee for one year 144 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sinkextruded aluminium complete 145 supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heatsink extruded aluminium complete 146 supplying and erecting led street light fitting suitable for above75w 90w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 147 supplying and erecting led street light fitting 100w, includingclass ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 148 supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 149 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminiumcomplete 150 supplying and erecting led flood light fitting of 200w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminiumcomplete 151 supplying erecting testing self contained water coolerwith stainless steel tank 40 litreshour & storage 80 litres 3 star 152 supplying and erecting 12v / 180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 153 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor ( igbt ) technology complete as per specification no. ap inv...

Department Of Atomic Energy - Maharashtra

39511867 bids are invited for sitc of cctv system and acess control system sitc of server , sitc of vms , sitc of l2 network switch , sitc of l2 plus network switch , sitc of camera , sitc of work station , sitc of monitor , sitc of patch cord , end termination cabe , exacavation of soil , sitc of gi pipe , rfid access conrol system , software of acess control system , biometric enrolling device , sitc of windows sever , upgradation of work station , supply installation of ms support , supply installation ms box , supply istallation cu earth wire total quantity : 4812...

Ministry Of Defence - Maharashtra

39489096 bids are invited for suppling fixing of 20a 240v spn industrial type socket outlet with 2 pole earth, metal enclosed plug top along with 20 , writing for circuit submain wiring alomngwith earth wire with the following sizes of frls pvc insulated copper conductor , 35mm x 35mm x 5mm galvanised slotted angle iron channel , 2 tr capacity split type air conditioner with inlet blower unit outdoor condenser unit insulated copper tubing remote control etc. complete in all respect , supply fixing of 5kva voltage stabilizer for split air conditioner , supply fixing of wall mounted bracket for outdoor unit. total quantity : 108...

Rural Development Department - Maharashtra

39447037 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

39216263 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Airports Authority Of India - Maharashtra

39073811 tender for construction of new dvorat aurangabad airport. sh: electrical works.; 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frlsh pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frlsh pvc insulated copper conductor single core cable etc as required.a ) group c 2 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 3 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 4 sq.mm + 1 x 4 sq.mm earth wire 4 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 6 sq. mm + 1 x 6 sq. mm earth wire 5 wiring for light / power plug with 2x4 sq. mm frlsh pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4 sq. mm frlsh pvc insulated copper conductor single core cable for loop earthing as required. 6 supplying and fixing of 25 mm sizes of medium class steel conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 7 supplying and fixing suitable sizegi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 8 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.telephone socket outlet 9 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15 / 16 a switch 10 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15 / 16 a socket outlet 11 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 module ( 75 mm x 75 mm ) 12 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.4 module ( 125 mm x 75 mm ) 13 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.6 module ( 200 mm x 75 mm ) 14 supplying and fixing of 6 way ( 8 +18 ) , double door , metal, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing, blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 15 supplying and fixing of 12 way ( 2+10 ) , double door, metal , single pole and neutral ( spn ) , metalica mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing , blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 16 supplying and fixing of 6 way ( 2+4 ) , double door, metal , single pole and neutral ( spn ) , metalica mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing , blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 17 supplying and fixing 63a rating, 415 v, 10 ka, 4 pole mcb suitable for inductive load in the existing tpn mcb db complete with connections, testing and commissioning etc. as required. 18 supplying and fixing 63a rating, 240 / 415 v, 10 ka, c curve, dp miniature circuit breaker suitable for inductive loadin the existing mcb db complete with connections, testing and commissioning etc. as required. 19 supplying and fixing of 32 amp rating, two pole, ( one phase and neutral ) , 415 / 240 volts, residual current breaker with overload protection ( rcbo ) , having a sensitivity current 100 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 20 supplying and fixing 5 a to 32 a rating sp mcb, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 21 supply of recessed mounting 2 x 2 led panel luminaire, 36w, ip 20, crca deep drawn housing suitable for 600 mm x 600 mm modular ceiling complete as per technical specifications. 22 installation, testing and commissioning of pre wired, led fitting / compact fluorescent fitting of all types, complete with all accessories etc. directly on ceiling / wall, including connection with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 23 supply of 36 watt led type road / street light with minimum protection level ip 66, pressure die cast housing with epoxy power coated prismatic poly carbonate cover with individual led lenses and complete assembly with led, driver and accessories pre wired up to terminal block i / c suitable mounting accessories etc. as required. 24 fixing of led street light fitting on pole / wall including supply and bending the suitable size gi pipe to the required shape, iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint including connection with 1.5 sq.mm pvc insulated copper conductor single core cable, testing and commissioning complete as required. 25 supply of bldc celling fan with remote control, 1200 mm sweep suitable for 230 volt, with 30 cm down rod, input power range 28 w , speed 350 rpm , air delivery 220 ccm , 5 years warranty and other accessories, canopies, etc. as required. 26 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq.mm frlsh pvc insulated, copper conductor, single core cable etc. as required. 27 supply and fixing of 12 w fully automatic emergency led light having back up time of 3 hours complete with standard accessories all as required. make: prolite or aai preffered make list. 28 supply and installation of astro mini time switch suitable for single phase 240v ac for lighting control based on sunrise / sunset timings by lattitude / longititude settings. ( time switch is to be installed near streetlight db of dvor building ) 29 supply of 230 v , 50 hz industrial heavy duty exhaust fan having 300 mm sweep 1400 rev / minute indculing installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 30 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal / coke and salt as required. 31 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i. pipe from earth electrode including connection with gi nut, bolt, spring, washer excavation and re filling etc. as required. 32 providing and fixing 25 mm x 5 mm gi strip on surface or in recess for connections etc. as required. 33 sitc of three phase neutral surge protection device ( spd ) in the lt panel or any suitable location, type 1+ 2 , 4 module, 3p+ n with inbuilt mcb havingmaximum discharge current 100ka ( 10 / 350 us ) ) , impulse current 8ka with protection level of 0 1.5 kv including allaccessories, conforming to iec 61643 11. 34 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 35 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 36 supplying and fixing of medium class g.i. pipe of 50 mm dia. ( nominal ) 02 metres length and to be grouted on concrete foundation with installation including base plate , nut bolts , washer etc complete as required on the roof. 37 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 38 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 39 providing joints by using brazing technique on 25 mm x 3 mm copper strip on surface or in recess for connections to another copper earth strip for interconnection to all earths of lightening arrestors, counterpoise , equipment and electrical power supply earthing etc. as required. 40 supply of following size xlpe insulated and pvc, sheathed aluminum conductor armoured lt power cable of 1.1 kv grade conforming to is 7098:1988 ( part i ) with up to date amendments etc. complete as required.3.5 x 240 sqmm alumimum conductor armoured cable. 41 supplying and laying of following sizedwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc. direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.135 mm dia id 42 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal / dwc hdpe pipe as required.above 185 sq. mm and upto 400 sq. mm 43 supplying and making end termination with brass compression gland and aluminium / copper lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 x 240 sq. mm ( 62 mm ) aluminimum 44 design, sitc of indoor type, floor mounted compartmentalized cubical type panel board of 415 volt ( nominal ) , fabricated out of 2 mm thick crca sheet, free standing and totally enclosed, ip42, confirming to is: 61439, weather proof / dust proof / vermin proof with bottom / top cable entries and cable alleys. the panel board shall be suitable for operation on 3 phase, 4 wire, 50 hz ac supply and with suitable size busbar, earth bar and following switchgear instrumentation and protection devices etc. complete with connections, interconnection, earthing, painting and marking as per site conditions etc complete as required as per the specifications. suuplier must take lt panel design approval from eic before the supply.i: incomer : a ) 160 a, mccb, 4p, 35 37 ka ( icu= 100% ics ) with extended rotary handle and spreaders 02 nos.b ) multi function meter ( shows voltage, current & frequency ) with 3 line lcd / led display of size 96 x 96 mm. 02 nos.c ) indication lamp r, y & b ( led type ) 02 setii: online manual chnage over switch 160a ; 4p ; 25 / 35 ka breaking capacity 1 no.industrial socket ; 63a; 4p 1 no. iii: automatic transfer switch with bypass switch arrangement for manual operation : a ) 200a, 4p, 415v, 50 hz automatic transfer switch.ii outgoing : a ) 100 a, mccb, 4p, 36 ka ( icu= 100% ics ) with extended rotary handle 02 nos. b ) 64a, mccb, 4p, 30 ka ( icu= 100% ics ) with extended rotary handle 03 nos. c ) indication lampr & g ( led type ) 05 set other :a ) 300a copper busbar, 3 phase and neutralb ) inbuilt spd 02 nos. ( type 1 +2 , 4 module , 3 p + n having maximum discharge current 100ka ( 10 / 350 us ) , impulse current 8 ka with protection level of 0 1.5 kv and it shall be installed after the incomer cable suitable with the panel load capactiy ) . c ) necessary ct & control wiring arrangement panel design should be approved from eic before the supply. 45 design, supply , installation , testing and commissioning of natural air cooled three phase voltage stabilizer of 30 kva capacity having input voltage range 340 480 volts and output voltage range : 415 + 1%, frequenct range : 47 53 hz , continuous duty cycle having all the metering to see input output voltage range with rate of correcton : 40v / seccomply with overload proction system and compatible to connect with existing lt panel.design should be approved from eic before the supply. 46 supply and laying of 135 mm dia hdpe pipe with hdd trenchless method direct in ground ( upto 07 meter below ground level ) in all type of soil, coupling of pipe etc complete as per requiement in all aspect. 47 providing , laying and fixing of non pressure np2 class ( light duty ) 150 mm r.c.c pipes with collers jointed with stiff mixture of cement morterin proportion of 1:2 ( 1 cement : 2 sand ) includingcutting / breaking pcc / bituminous area upto suitable depth and 400 mm width andremaking the same as good as previousetc. complete as required. 48 supply and laying of insultion mats of 2 mm thicknessx 1 m wide polysynthetic mats conforming to is 15652 : 2006, class a up to 3.3 kv along with suitable adhesive etc complete as required. 49 constructing masonry chamber 60x60x90 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand ) for lt cable chamber and requires rcc top slab biparting type having minimum 6 inch thickness, 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) to cover the entire area of chamber with proper lifting arrangement , i / c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5. 50 supply installation testing and commissioning of ip65 mi combinable type bus bars junction box with 250 amps ( tinned cu ) bus bars, should be made of high quality polycarbonate pc gfs ( totally insulated class ii ) ( shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material ) , uv resistant, having high grade gasket made of polyurethane, should withstand glow wire test at 9600c, should be flame retardant, materials suitable for outdoor application and the enclosure should have pre moulded knock out for cable entry on side walls and enclosure should have pc hinged option. for cable entry from bottom part a de touchable type pc flange should be fitted with plain wall. the plain wall of flange can be drilled as per cable size. lid screws should be made of polyamide spring loaded half turn type and to open a triangular key or tool will be required. inside enclosure should have lot of self threaded holes so that mounting plate / bus bars can be mounted easily.degree of protection : ip 65 _busbar rating: 250a ( rybn: 30 x 06 ) mm cudimensions : 500 [ l ] x 1075 [ h ] x 630 [ d ] mm_ given cable size : 3.5c x 240 sq.mm al. cable ( loop in / loop out ) mounting type : outdoor / floor mounting ( frp frangible frame ) 51 supply of 5 star rating fully inverter split type air conditioner of 1.5 tr ( minimum iseer 4.5 ) capacity with compressor type rotary / bldc / swing type, different cooling capacities for different cooling needs, fitted withrotary / scrollcompressor of min 05 years warranty, having copper condenser coil, operating for refrigerant r32 eco riendly green gas andindoor unit suitable for wall mounting operation with cordless lcd / led remote, auto restart operation, connecting copper refrigerant pipes ( with suitable nitrile insulation including charging of suitable refrigerant gas, 4c x 4 sq.mm copper cable, drain pipe ) up to 3mtr. and suitable for operating on 230v ±10%, 50hz, single phase, ac , control wiring, thermostat, washable synthetic air filter etc. complete ascapable of performing cooling, dehumidifying, air circulating, filtering functions, stablizer free operation etc. meeting the technical specifications and make as per the list of approved make. 52 installation, testing and commissioning of split type air conditioner of upto and including1.5trcapacity and fixing of refrigerant copper piping ( including extra refrigerant pipe also, if any apart from standard length ) of suitable size for both suction and discharge along with suitable nitrile / thermal insulation andelectrical cable ( 4c x 4 sq.mm ) of size having suitable size of copper conductor for connection from indoor to outdoor unit including charging of suitable refrigerant gas, providing mounting stand for out door unit and equivalent single phase industrial socket ( 20a ) for ac on / off purpose and all suitable necessary accessories complete as per site requirement. 53 supply of extra refrigerant copper piping for 1.5tra.cof suitable size for both suction and discharge along with suitable thermal insulation andelectrical cable of suitable size copper conductor for connection from indoor to outdoor unit and suitable necessary accessories for connection complete as required. ( one length of suction piping , one length of discharge piping and one length of copper wire shall be measured one meter for this item ) 54 supply and fixing of 75mm dia medium class pvc pipe for coveringrefrigerant copper pipingfor both suction , discharge and electrical cable with suitable necessary accessories for pipe connection complete as required. 55 supply and fixing of hard upvc drain pipe of 25 mm dia connection from indoor to outside of wall including bends, sitable insulation , u straps , clamps and necessary accessories for connection etc. complete as required. 56 supply and fixing of 5kva, 15amp / 130v 300v digital electronics voltage stabilizer of wall mounting type with instant start and intelligent time delay provisionssuitable for 1.5 tr split ac units. 57 supply and fixing of smart controller / timer with 4 hr / 8 hr duration, 25a capacity, having ov & uv indication / protection suitable for ac power supply 240 v, 50 hz. etc. complete as required. 58 supply of floor mounted bubble top water dispenser having cold and hot water storage capacity of minimum 3.2 ltr and 1.0 ltr with use of non cfc eco friendly gas refrigrent, cooling capacity minimum 2.5 ltr / hr, heating capacity minimum 5 ltr / hr with cabinet / refrigerator capacity : 20 litres led indicator and 3 faucets ( normal / hot / cold ) mode function with 02 nos , 20 ltr can etc complete as required. 59 supply and laying of 2 core , 1.5 sq. mm . fire survival cable , armoured copper conductor of 600 / 1000 v grade, insulated with specially formulated pvc , coated with special fire resistance materials and overall sheathed with special pvc, with special properties as zero halogen low smoke insulation basic construction as per bs 7846 2009 & cuircuit integrity as per bs 6387 c.w.z / bs en 50200. 60 supplying, installation, testing & commissioning ofconventional fire alarmpanel , 16 x 2 dotmatrixlcd display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per is:2189, complying relevantnational fire alarm code for local fire alarm systemwith mimic diagram for all area / zone covered, complete with all connections. the panel shall have input of 240 volts ac power supply, inbuilt automatic battery charger, 24 volts, 2 x 12 volts, 12 ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. the panel shall be ul listed & fm approved and along with gsm auto dialer facility ( 20 nos min. ) etc. as required. 61 supply, installation, testing & commissioning of ul / en listed ( latest version ) conventionalsmoke detectorwith inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible led, fully coated circuit board, superior rf / transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of lexan ( or polycarbonate ) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications , complete as required. ( cost of plug in common base shall deemed to be included in cost of detectors ) . 62 supply, installation, testing & commissioning of ul / en listed ( latest version ) conventional manual call station ( resetable pull / push type ) suitable for semi flush mounting, ip 54 for indoor use & ip 65 for outdoor use with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test reset lock. manual pull station shall be connected with two wire to slc loop of fire control panel. cover shall be made out of lexan ( or poly carbonate equivalent ) with clear operating instruction and the word fire appearing on the front complete with connections etc. as required and as per enclosed specifications. 63 supply, installation, testing and commissioning of ul / en listed ( latest version ) loop powered addressable hooter cum strobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of min. 90 db to max. 120 db at 1m distance complete with termination etc. as required and as per enclosed specification. 64 sitc of 4.5 kg co2 type automatic fire extingusher with sprinkler head for spot type protection i / c mounting accessories etc complete as required....

Mira Bhaindar Municipal Corporation - Maharashtra

38954916 supply and installation of cctv components at mbmc properties, buildings, gardens, play grounds, esr, lake surroundings, statues, hospitals, health centers, schools, cemeteries, and other locations in mbmc area=2 item no 1supplying & erecting 4mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 3 item no 2supplying & erecting 5mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 4 item no 3supplying & erecting 8mp ip bullet outdoor camera ir dist upto 30 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 5 item no 4supplying & erecting 4mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 6 item no 5supplying & erecting 5mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 7 item no 6supplying & erecting 8mp ip bullet outdoor camera ir dist upto 50 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 8 item no 7supplying & erecting 4mp ip bullet outdoor camera ir dist upto 80 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 9 item no 8supplying & erecting 5mp ip bullet outdoor camera ir dist upto 80 mtr, audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 10 item no 9supplying & erecting 4mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 11 item no 10supplying & erecting 4mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic, built in micro sd slot upto 256gb (market rate) 12 item no 11supplying & erecting 5mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 13 item no 12supplying & erecting 5mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic,built in micro sd slot upto 256gb (market rate) 14 item no 13supplying & erecting 8mp fixed lens ip dome indoor camera 30 mtr ir dist (market rate) 15 item no 14supplying & erecting 8mp fixed lens ip dome indoor camera 30 mtr ir dist with built in mic,built in micro sd slot upto 256gb (market rate) 16 item no 15supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 30 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 17 item no 16supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 30 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 18 item no 17supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 50 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 19 item no 18supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 50 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 20 item no 19supplying & erecting 5mp verifocal lens (2.7 13.5mm) ip bullet outdoor camera 100 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 21 item no 20supplying & erecting 8mp verifocal lens (2.8 12mm) ip bullet outdoor camera 100 mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 22 item no 212mp ip ptz 25x optical zoom 150mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 23 item no 224mp ip ptz 25x optical zoom 100mtr ir dist with audio input, built in micro sd slot upto 256gb as per the technical specifications, as per instructed by engineer incharge (market rate) 24 item no 23ptz joystick with 1 rs 232, 2 rs 485,used to control ptz dome, four dimensional joystick (market rate) 25 item no 24ptz joystick with 102 screen, 1 * rs232,1 * rs485,1 * hdmi output,1 * rj45 port, 1 * usb interface,1 * standard 3.5mm audio jack, four dimensional joystick (market rate) 26 item no 25supplying & erecting 4 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 27 item no 26supplying & erecting 4 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth, 4 rj45 10m/100m poe network interfaces, 1 hdd support each with upto 6tb (market rate) 28 item no 27supplying & erecting 8 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 29 item no 28supplying & erecting 8 channel nvr with up to 320 mbps incoming bandwidth & 180 mbps outgoing bandwidth, 2 hdd support each with upto 8tb (market rate) 30 item no 29supplying & erecting 8 channel nvr with up to 80 mbps incoming bandwidth & 64 mbps outgoing bandwidth, 8 rj 45 10m/100m self adaptive ethernet interface,2 hdd support each with upto 10tb (market rate) 31 item no 30supplying & erecting 16 channel nvr with up to 64 mbps incoming bandwidth & 48 mbps outgoing bandwidth,1 hdd support each with upto 8tb (market rate) 32 item no 31supplying & erecting 16 channel nvr with up to 320 mbps incoming bandwidth & 320 mbps outgoing bandwidth, 2 hdd support each with upto 8tb (market rate) 33 item no 32supplying & erecting 16 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 4 hdd support each with upto 10tb (market rate) 34 item no 33supplying & erecting 32 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 4 hdd support each with upto 10tb (market rate) 35 item no 34supplying & erecting 32 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 8 hdd support each with upto 10tb (market rate) 36 item no 35supplying & erecting 64 channel nvr with up to 384 mbps incoming bandwidth & 384 mbps outgoing bandwidth, 8 hdd support each with upto 10tb (market rate) 37 item no 36supplying & erecting big size ( approx 12 14 inch ) outdoor shockproof, rustproof,weatherproof junction box with pole mounting clamp for poe switch, media converter & electric power sockets as per instructed by engineer incharge (market rate) 38 item no 37supplying & erecting small size ( approx. 4 6 inch ) outdoor weatherproof junction box for camera rj45 port, dc pin port, camera connectors & audio/alarm i/o port as per instructed by engineer incharge (market rate) 39 item no 38supplying & erecting 1tb internal sata hard drive(market rate) 40 item no 39supplying & erecting 2tb internal sata hard drive(market rate) 41 item no 40supplying & erecting 4tb internal sata hard drive(market rate) 42 item no 41supplying & erecting 6tb internal sata hard drive(market rate) 43 item no 42supplying & erecting 8tb internal sata hard drive(market rate) 44 item no 43supplying & erecting 10tb internal sata hard drive(market rate) 45 item no 44supplying & erecting 6 8ft fabricated angle for camera mounting as per instructed by engineer incharge(market rate) 46 item no 45supplying & erecting 3 4ft fabricated angle for camera mounting as per instructed by engineer incharge(market rate) 47 item no 46supplying & erecting waterproof gel in camerasrj45 jack(market rate) 48 item no 47supplying & erecting core to core fiber splicing(market rate) 49 item no 48supplying & erecting wireless mouse for nvr(market rate) 50 item no 49supplying & erecting 4x4 pvc surface box for camera(market rate) 51 item no 50media converter rack (sanctioned rate) 52 item no 51supplying & erecting 32 inch led tv with wall mounting kit(market rate) 53 item no 52supplying & erecting 43 inch 4k led tv with wall mounting kit(market rate) 54 item no 53supplying & erecting 55 inch 4k led tv with wall mounting kit (market rate) 55 item no 54supplying & erecting wire rope of 3/4/6mm dia. having 6/19 construction as per is complete with termination in provided eye bolts including dismantling of existing accessories. (market rate) 56 item no 55supply and erecting 440v protector with type 2 surge protection for over voltage protection for 1/2 kva ups (market rate) 57 item no 56fabricated battery racks (market rate) 58 item no 57fabricated ups stand (market rate) 59 item no 58connecting & linking cables for ups & batteries (market rate) 60 item no 59256gb memory card (market rate) 61 item no 60supplying and erecting 5m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 22 62 item no 61supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 23 63 item no 62supplying and erecting 15m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 24 64 item no 63supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 25 65 item no 64supplying and erecting 25m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. dsr 1 8 26 66 item no 65supplying & erecting hdmi extender over rj45 ethernet cable cat 6, 60m/200ft complete.1 8 28 67 item no 66supplying, installing, testing & commissioning of dvi to hdmi convertor highspeed category, supporting full hd 1080p, 2k and 4k video up to 30 ft length, 3d having 24k gold plated 19 pin type a connectors with high flex cl3 rated jacket, rohs compliant complete. dsr 1 8 29 68 item no 67supplying, fixing, and configuring 8 ports managed gigabit, layer 2 switch, 10/100/1000 base t, poe smart switch plus 2 sfp erected in provided rack complete. dsr 1 11 2 69 item no 68supplying, fixing, and configuring 8 ports 1 g unmanaged gigabit poe switch erected in provided rack complete.dsr 1 11 1 70 item no 69supplying and fixing 6u wall mount rack (dimension dxwxh – 500x600x367 mm) as per specification no. wg nas/rak dsr 1 12 17 71 item no 70supplying and fixing 9u wall mount rack (dimension dxwxh – 500x600x500 mm) as per specification no. wg nas/rak dsr 1 12 18 72 item no 71supplying and fixing power distribution unit for networking rack comprises of 6/16a (6 nos. sockets), 25 a modular mcb, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification no. wg nas/rak. dsr 1 12 16 73 item no 72supplying and fixing 1 m utp patch cord of cat 6 type in position as per specification no. wg coc/pc. dsr 1 10 16 74 item no 73supplying and fixing 2 m utp patch cord of cat 6 type in position as per specification no. wg coc/pc. dsr 1 10 18 75 item no 74supplying, fixing, and configuring media convertor 1000 base t to 1000 base sx sc multi mode media. dsr 1 12 38 76 item no 75supplying and installing 3 m fibre patch cord duplex single mode for os1/os2 complete. dsr 1 10 21 77 item no 76supplying and fixing ip66 enclosure for fibre splicing complete. dsr 1 10 29 78 item no 77supplying and fixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided u rack complete as per specification no. wg nas/ liu. dsr 1 12 5 79 item no 78supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided u rack complete as per specification no. wg nas/ liu. dsr 1 12 7 80 item no 79supplying and fixing sc/lc type multimode duplex adapter to couple two connectors between ofc & fibre switch/fibre module as per specification no. wg nas/mma. dsr 1 12 11 81 item no 80supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125µm (os1/os2) 10/40 gbps speed in provided underground hdpe pipe complete. dsr 1 10 9 82 item no 81supplying and installing armoured single mode optical fibre cable with 12 fiber, core dia 50/125µm (os1/os2) 10/40 gbps speed in provided underground hdpe pipe complete. dsr 1 10 10 83 item no 82supplying and installing cat 6 lszh cable suitable for networking as per specification no. wg coc/nc. dsr 1 10 3 84 item no 83supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw. dsr 1 7 11 85 item no 84supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw. dsr 1 3 6 86 item no 85supplying and erecting rigid steel conduit 16 swg 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 1 87 item no 86supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 3 88 item no 87supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no:wg ma/cc. dsr 1 1 5 89 item no 88supplying and erecting hms pvc conduit frls grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc.dsr 1 1 7 90 item no 89supplying and erecting hms pvc conduit frls grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. dsr 1 1 9 91 item no 90supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. dsr 1 1 11 92 item no 91supplying and erecting pvc trunking (pvc casing n capping) of size 20 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 6 93 item no 92supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 7 94 item no 93supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 8 95 item no 94supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. dsr 1 2 9 96 item no 95supplying and erecting pvc box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box. dsr 1 2 11 97 item no 96supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. dsr 1 2 13 98 item no 97supplying and installing cat 6 cable with rodent proof and anti termite jacket suitable for networking as per specification no. wg coc/nc. dsr 1 10 6 99 item no 98supplying and installing cat 6 armoured cable with eccs tape suitable for networking as per specification no. wg coc/nc dsr 1 10 7 100 item no 99supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu. dsr 7 2 14 101 item no 100supplying and erecting pole clamp made from 50 x 6 mm ms flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. dsr 8 6 10 102 item no 101supplying and erecting isi mark gi pipe 75/80 mm dia ‘c” class position with accessories complete. specification no. cw plb/gp. dsr 16 5 14 103 item no 102supplying and erecting isi mark gi pipe 50 mm. dia ‘c” class position with accessories complete. specification no. cw plb/gp. dsr 16 5 12 104 item no 103supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete.. dsr 7 6 9 105 item no 104making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr. dsr 16 1 2 106 item no 105supplying, installing & testing utp connector (rj 45) as per specification no. wg nas/utpc as per dsr 1 12 1 107 item no 106supplying and erecting 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. dsr 1 6 45 108 item no 107supplying and erecting pvc surface modular switch box with double mounting plate for 1 module duly erected in an approved manner.dsr 1 6 26 109 item no 108supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected in an approved manner.dsr 1 6 27 110 item no 109supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected in an approved manner.dsr 1 6 28 111 item no 110supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected in an approved manner.dsr 1 6 29 112 item no 111supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected in an approved manner.dsr 1 6 30 113 item no 112supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. dsr 1 6 31 114 item no 113supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. dsr 1 6 32 115 item no 114supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. dsr 1 6 33 116 item no 115supplying and erecting 6 to 32 a, 10ka, spmcb suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. dsr 1 6 44 117 item no 116supplying and erecting 16 to 32 a, 10ka, dpmcb suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. . dsr 1 6 45 118 item no 117supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. dsr 1 6 10 119 item no 118supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip. dsr 8 1 16 120 item no 119providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. dsr 8 2 11 121 item no 120providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. dsr 8 2 12 122 item no 121poviding cement concrete foundation including excavation for the poles (45 cm x 45 cm x 120 cm) deep in 1:3:6 cement concrete (20 to 25 mm stone metal) and 45 cm x 45cm x 45 cm / 45 cm dia.x 45 cm height plinth duly plastered and with necesarry curing and finishing in an approved manner (for 6 m pole). dsr 16 3 2 123 item no 122excavating hard rock or bituminous road (b.t.) by chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good. dsr 16 1 5 124 item no 123supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non corrosive bond with required joints as per specification no. ea ep. dsr 9 2 7 125 item no 124providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la. dsr 9 1 6 126 item no 125supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. dsr 9 3 1 127 item no 126supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of 2hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups. dsr 3 7 1 128 item no 127supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of 2hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups 129 item no 128supplying and erecting 12v/100ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete.dsr 3 8 2 130 item no 129supplying and erecting 12v/150ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete. 131 item no 130supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. dsr 1 4 4 132 item no 131 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu. dsr 7 2 15 133 part b. maintenance 134 comprehensive maintenance for second year 135 comprehensive maintenance for third year 136 comprehensive maintenance for fourth year 137 comprehensive maintenance for fifth year ...

Bhiwandi Nizampur City Municipal Corporation. - Maharashtra

38914089 providing and fixing of office furniture, computer, ups, printer, scanner, ac, tube light, cctv and power point at e library in newly constructed bhiwandi court building. mp fund 2 providing and arrangemnt of mid backecocts mechanismfixed arm restgasliftfor seat height adjustmentstandard 5 prong pnylon base with fabric upholstery 3 providing and fixing partition 4mm thick indian teak veneer on one side and 6mm commercial type plywood on the other side including c.t.w.frame of 70x35 mm at 60cm cc on both waysincluding finishing with french polishing to veneer face and oil paintingfrench polishing to other face etc.complete. without skirting 4 providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directedall necessary beadsmouldings and lippingwrought iron hold fastschromium plated fixtures and fasteningswith brass mortise lockchromium plated handles on both sidesand finishing with french polish etc. complete. 5 3 drawer pedestal unit392l x 450d x 680ht. mm. 3 drawer pedestal unit having overall size 392l x 450d x 680ht.mm. with central lock and key. 3 drawer sandbody are complete metal with powder coat finish facia in 18 mm prelaminated particle board. 6 conference table 3600l x 1400d x 750 ht providing andfixing of maintable 3600l x 1400d x 750ht made up of 188mm thick mdf top with pvcmembrane finish and water fall edge profile. aluminium anodiziedfinish beeding of 4mm thichis running all over the table top edge. gableendsis aerofoild shape with front edges in pvc membrane finish and rest in prelaminated mdf with batton structure. gableends should be hollow rominside for the provision of passing electrical and data wiring.modesty panelto be made of 18mm thick prelaminated particle board with pvc edge band access flap for wire manager 2 nos. 7 medium height steel storage 750l x 450d x 1200ht providing and fixing openable steel storage of 750 x 450 x 1200ht with 2 adjustable shelve complete body andshutter made in 0.8 mm thick andtop in 2 mm thick crca2 shutter to be mounted witht he help of cuphingesand 4 adjustable levelersenitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing. 8 supplying erecting testing and commissioning ofdell vostro desktop core i3 12100 12th gen with gigabytes h610 mb8 gbddr4 2933 mhz ram 512 gb nvme powercabinet smps i ball wired keyboard mouse setintex led 19.5 inchwindows 10 pro msoffice 2021 9 supplying erectingtesting and commissioning of intex ups 600va12v 10 supplying erecting testing and commissioning of hp laserjet p1108 single function printer 11 supplyingerectingtesting and commissioning ofhp 2000h2 adf scanner 12 point wiring for lightbellexhaust fan in pvc trunkingasingcapping with 1.5 sq.mm 21efrlsh grade copper wiremodular type switchearthing and required accessories as per specification nowgpwsw 13 wiring for plug on board with switch socket surfaceconcealed typecopper wiring and earthing and with modular accessories as per specification nowgpw cw 14 point wiring for independent plug in pvc trunkingcasing capping with 1.5 sq.mm 21e frlsh grade copper wiremodular type switch earthing and required accessories as per specification nowgpwsw 15 supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. 16 supplying and erecting pvc surface modular switch box with double mounting andfront plate for 8 module complete duly connected. 17 supplying and erecting modular type switch 16 20 a with indicatorduly erected on provided plate and box with wiring connections complete. 18 supplying and erecting modular type 3 pin 6 16a multi socket with safety shutterduly erected on provided plate and box with wiring connections complete. 19 supplying and erecting modular type 3 pin 6a multi socket with safety shutterduly erected on provided plate and box with wiring connections complete. 20 supplying and erecting crca powder coated corridor passage light led fitting4 feetmax. 17w with high transitivity diffuser with system lumens output of min2000 lumens min. efficacy of 120 lumenwcri80cct upto 6500kbeam angle of 120 deg.ripple5 persentage thd10 persantagep.f. 0.95operating range of 120270vsurge protection of 4 kvlife class of 50000 hrs. at l70b50 including driverwith end caps on provided pvc block wooden board with 3 years warranty. 21 supplying erecting andterminating xlpe armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm.12swgg.i. earth wire complete erected with glands and lugson walltrussespole or laid in provided trench pipe as per specification no. cb ltal 22 supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit trunkinginside polebus bars or any other places.as per specification no wgmabw 23 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduittrunking inside polebus bars or any other places. as per specification no wg ma bw 24 supplying and erecting mains with 1x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduittrunkinginside polebus bars or any other places. as per specification nowg ma bw 25 supplying and erecting pvc trunking pvc casingncappingof size 25 mm with accessories on wallceiling as per specification nowg macon. 26 supplying anderecting triple pole and neutral distribution board tpndb spmcb of 4 waysphase12 poleswith door1.2mm thicknesssurfaceflush mountedip 43 protection on irongi frame horizontal busbar typeas per specification no swswrmcbdb 27 supplyingerecting andmarking fpmcb 40a to 63awith rated short circuit breaking capacity icn10ka in provided distribution board as per specification no. swswrmcb 28 supplying erecting andmarking spmcb 6a to 32a c series with rated shortcircuit breaking capacity icn10ka in provided distribution board as per specification no swswrmcb 29 supplying installing testing andcommissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressorroom air conditioning unit 2.1tr to 2.3tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v50 hza.c. supply having 1 no of air handling unit hi wallfloor mounting type complete with refrigerant r32 having copper condenserminimum 2.5pm filterself diagnosis featurestabilizer free operation andtemperature display on indoor unitnoise level maximum 50dba at position as per specification no. apacwac 30 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materialstesting andrecording the results as per specification no. eaep 31 supplying and erecting dvr 4 channel for cctv. 32 supplying and erecting bullet camera for cctv. 33 supplying and erecting 2 tb hard disk for cctv. 34 supplying and erecting connectorfor cctv. 35 supplying and erecting 10 a smpsfor cctv. 36 supplying and erecting 3 1 cctv copper cable for cctv. 37 supplying and erecting led monitor 22 for cctv. 38 supplying and erecting 4u rack cabinet for dvr...

Central Reserve Police Force - Maharashtra

38899024 repair and painting of mess of barrack no. 02 of gc crpf nagpur, maharashtra.; 1 civil works : 2 dismantling doors, windows and clerestory windows ( steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below. 3 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. for thickness of tiles 10 mm to 25 mm. 4 providing and fixing factory made upvc white colour fixed glazed windows / ventilators comprising of upvc multi chambered frame and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , , upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes and silicon sealant shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.note: for upvc frame, sash and mullion extruded profiles minus 5%tolerance in dimension i.e. in depth & width of profile shall be acceptable.fixed window / ventilator made of ( small series ) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( area upto 0.75 sqm. ) 5 providing and fixing factory made upvc white colour casement / casement cum fixed glazed windows comprising of upvc multi chambered frame, sash and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , upvc extruded glazing beads of appropriate dimension, epdm gasket, stainless steel ( ss 304 grade ) friction hinges, zinc alloy ( white powder coated ) casement handles, g.i fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame & sash shall be mitred cutand fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes and silicon sealant shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.casement window double panels with top fixed with s.s. friction hinges ( 350 x 19 x 1.9 mm ) made of ( small series ) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( area of window upto 2.50 sqm ) . 6 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 7 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: cement mortar 1:6 ( 1 cement : 6 coarse sand ) . 8 12 mm cement plaster of mix : 1:6 ( 1 cement: 6 fine sand ) 9 wall painting with acrylic emulsion paint, having voc ( volatile organic compound ) content less than 50 grams / litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. two coats. 10 painting with oil type wood preservative of approved brand and manufacture: old work ( one or more coats ) 11 finishing walls with acrylic smooth exterior paint of required shade : old work ( two or more coat applied @ 1.67 ltr / 10 sqm ) on existing cement paint surface. 12 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . kiln seasoned and chemically treated hollock wood. 13 providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer in charge. ( note: butt hinges and necessary screws shall be paid separately ) . kiln seasoned and chemically treated hollock wood. 30 mm thick shutters. 14 electrical works: 15 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required. group b 16 supplying and fixing piano type 5 / 6 amps switch on the existing switch box / cover including connections etc. as required. 17 supplying and fixing piano type 3 pin 5 / 6 a socket outlet on the existing switch box / cover including connections etc. as required. 18 supplying and fixing piano type 15 / 16 a switch on the existing switch box / cover including connections etc. as required. 19 supplying and fixing piano type 6 pin 15 / 16 a socket outlet on the existing switch box / cover including connections etc. as required....

Military Engineer Services - Maharashtra

38896738 tender for provision of meditation / yoga centre at pune and mw work of age b / r ( central ) under ge ( n ) pune ; 1 surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out soft / loose soil complete all as per specified and as directed 2 excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc1.5 m in depth and getting out soft / loose soil complete all as per specified and as directed 3 m&l for pcc 1:4:8, type d2 ( 40mm graded stone aggregate ) in foundations, filling and mass concrete complete all as per specified and as directed 4 m&l for rcc m 25 ( design mix ) ( using 20mm graded aggregate ) as in foundations, including rafts, footings, foundation beams;plinth beams; bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as per specified and as directed 5 m&l forrcc m 25 ( design mix ) ( using 20mm graded aggregate ) as in columns, pillars, piers, posts and struts complete all as per specified and as directed 6 ditto all as per item no 5 here in before but beams, cantilevers, bressummers, lintels over1.5m span and similar works etc 7 formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams and similar work vertical or to batter in rough finished surfaces complete all as per specified and as directed 8 ditto all as per item no 07 here in before but columns 9 ditto all as per item no 07 here in before but roof beams, bressummers, lintels, cantilevers, shelves and simiar work etc complete all as per specified and as directed 10 s&f for mild steel tmt bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clip complete all as per specified and as directed 11 ditto all as per item no 10 here in before but 6mm to 8mm bars for stirrups 12 m&l for pre cast cement concrete block masonry with solid blocks with pcc 1:3:6, type c 1, ( 20mm graded aggregate ) exc10cm in width and setting in mortar complete built in cm 1:6 in any description complete all as per specified and as directed 13 m&l for rendering 15mm thick on fair faces of brick work or concrete surfaces cm 1:6 fair and even complete all as per specified and as directed 14 ditto all as per item no.13 here in before, but 15mm thick plaster in cm 1:4 on other than fair faces of brick work complete all as per specified and as directed 15 m&l for roof trusses ( framed ) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats, plate etc fe 410 w ( gde e 250 ) quality a complete all as per specified and as directed. 16 s&f mild steel screw bolts ( machine made ) 16 to 20mm dia with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm and n.exc 10cm long fixed to any framed structure or any other required places complete all as per specified and as directed 17 s&f in pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as per specified and as directed 18 ditto all as per item no 17 here in before but 0.50mm thick plain sheets on ridges 19 m&l for hardcore of broken stone or boulders of gauge n exc 63mm, deposited, spread and levelled in layers n exc15cm thick, watered and rammed to a true surface complete all as per specified and as directed 20 m&l for 75mm thick pcc 1:4:8 type d 2 ( 40mm graded agg ) as in sub base of floor complete all as specified and directed by engr in charge 21 m&l for 50mm thick pcc 1:2:4 type b 1 ( 20mm graded agg ) as in floor to smooth finishes using extra cement complete all as specified and directed 22 m&l for 20 25mm thick makrana white marble floor over 15mm thick screed bed in cm 1:6 over sub base of floor complete all as specified and directed by engr in charge 23 m&l for machine cut kota stone slab flooring 20 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polished surfaces including 15mm thick screed bed or bedding of layer in cm 1:6 complete all as specified and directed. 24 m&l granite ( of any type ) , 18 20mm thick ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking platform, whb plateform and like in cement mortar ( 1:4 ) incl pointing in white cement ( 1:2 ) using marble dust with admixer of pigment to match with marble shade including 10mm thick backing of cement plaster in cm 1:3 complete all as per specified and as directed 25 m&l for granite ( of any type ) work ( table rubbed and polished ) for wall lining ( veneering to wall ) 12mm thick in cement mortar ( 1:3 ) and pointing with white cement ( 1:2 ) using marble dust with admixture of pigment to match with shade of granite complete all as per specified and as directed 26 m&l glazed ceramic coloured cladding tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick backing coatin cement mortar 1:4 complete all as per specified and as directed 27 m&l rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as per specified and as directed 28 s&f powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc and aluminum frame work wt not less than 1.25kg / m for door / window etc complete all as per specified and as directed 29 s&f aluminium powder coated three track sliding window with two glazed shutters with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, pvc rubber lining etc complete all as specified and as directed. catlouge numbers of jindal company or equivalent make complete all as specified and directed. sections of jindal company : three track bottom – 20957, three track top / vertical – 20958, handle – 20606, interlocking – 20605, top and bottom – 20604. 30 s&f aluminium powder coated fixed type ventilator using rectangular tube of size 50 x 25 and 1.50 mm including 3.50 mm thick plain glass using ‘jindal” aluminium section complete all as specified and directed. 31 s&f powder coated aluminium grill ( anodised transparent or dyed to required shade according to is:1868 with minimum anodic coating of grade ac 15 ) of approved design / pattern, with approved standard section and fixed to the existing window frame with c.p brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of engr in charge. 32 s&f 12mm thick toughned frosted glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required incl necessary stainless steel frame work, handles, locking device etc complete all as per specified and as directed 33 m&l double action floor spring hydraulically regulated made up of minimum 1.25 mm thickaluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as per specified and as directed 34 removing excavated soil n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as per specified and as directed 35 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed 36 m&l for 12mm thick mineral fibre false ceiling board on and including gi powder coated grid work of size 605mm x 605mm with using 32.0 mm x 23.5mm x 1.5 mm thick main tee, 26.5 mm x 23.5 mm x 1.28 mm cross tee and 23.5mm x 23.5mm x 1.5 mm angle fixed to wall for false ceiling including necessary supporting hanger with 3.0 mm dia gi wire and j bolts washer nuts for securing frame work to ceiling, suspended @ 120 cm c / c both ways, complete all as specified and as directed. make :armstrong, diaken, new age. note: any height of ceiling 37 m&l for preparation of new plastered surfaces of wall and applying two or more coats of 100% premium acrylic emulsion paint having voc less than 50 gm / litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade ( company depot tinted ) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10sqm over new surfaces complete all as specified and directed. 38 m&l for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. 39 m&l for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by engr in charge 40 m&l for mild steel framed work such as grill , gate etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders framed baluster, walk way railing frmae work including pintle hinges, stops, hand made sliding bolts etc and similar work using mild steel square or rectangular tubes complete all as specified and as directed 41 s&f gi dash fastener 8 to 10 mm dia and 100 to 125 mm long with gi washer of suitable dia and thickness and nut including drilling hole in masonary / concrete wall by means of electricals driven drill machine complete all as per specified and as directed 42 s&f polycarbonate fibre glass ( sandwich pattern ) corrugated / plain sheeting 6 mm thick hollow section fixed with coach screw and washer in roof, wall etc complete all as per specified and as directed 43 m&l for preparation of old surfaces and applying two coats of weather prrof exterior emulsion paint ( apex brand of asian or equivalent brand berger / shalimar ) over one coat of primer on wall complete all as per specified and as directed 44 material and labour for point wiring using approved colour coding as per is , with multistranded copper conductor 1.5 sqmm ( nominal area ) , two single core, pvc insulated and unsheathed frls cable 1100 volts grade isi 694 marked drawn through in and including heavy duty pvc concealed conduit including all accessories, metal flush box of suitable module, with earth dolly, covered with twin colour ( specified by engr in charge ) modular white cover plate & frame after chasing in brick / stone masonry walls etc for accomodating modular switches, sockets, regulators etc including pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frls cable as earth continuity conductor along with wiring and connecting to earth dolly, providing copper cable sockets plate / bottle type of adequate size at termination end of cable point wiring in dbs, switch boards, fittings fixtures all as specified and as directed for the following 45 one light / wall / exhaust fan pointcontrolled by one, one way switch 6 amps complete all as specified and as directed 46 one ceiling fan point controlled by one, one way switch 6 amps and regulatornote :pvccasing caping / pipe of size as required at site on surface of ceiling ( only for fan point ) in lieu of concealed is permitted and is deemed to be included in the unit rate quoated. 47 onebell pointcontrolled by one, one way switch 6 amps complete all as specified and as directed 48 one5 pin socket outlet plug point, 6 amps, controlledby one, switchon same board complete all as specified and as directed 49 one5 pin socket outlet plug point, 6 amps, controlledby one, switchon independent board complete all as specified and as directed 50 description all as per 1 here in before but using 2.5 sqmm single core copper conductor frls cable of multistranded pvc insulated unsheathed 1100 volts grade for one 6 pin socket outlet plug point, 16 amps independentincluding necessary running of 2.5 sqmm pvc insulatedmultistranded copper conductor single core frls cable as earth continuity conductor along with wiring and connecting to earth dollyproviding copper cable sockets plate / bottle type of adequate size at termination end of cable point wiring in dbs, switch boards, fittings fixturesall as specified and as directed 51 supply and fixingmodular switch 6 amps, single pole one way, one module complete all as specified andas directed. 52 supply and fixingmodular bell push 6 amps, single pole one way, one module complete all as specified andas directed. 53 supply and fixingmodular switch 16 amps, single pole one way, one module complete all as specified andas directed. 54 s & fmodular socket outlet multipurpose 6 amps, 5 pin, 2 module, complete all as specified andas directed. 55 s & fmodular socket outlet multipurpose 16 amps, 6 pin shuttered type, 2 module, complete all as specified andas directed. 56 supply and fixing, ding dongbell suitable for operation on ac. 230 volts, single pole complete all as specified andas directed. 57 supply and fixing modular fan step regulator, 120w 2 module suitable for ( 48 & 56 fans ) supply complete all as specified and as directed. 58 s & f ceiling rose, 3 phase / pvc / polycarbonate, complete all as specified andas directed 59 supply and fixing20 / 22 wattinverter led battenaluminium body with opal diffuser, ip20, battery back up & functioning as per product tds with intregrated electronic driver, connector block, holder, decorative end caps, led tube light etc complete with all accessories prewired and mounting pvc rectangular block, including provision of flexible copper conductor cable of suitable size from ceiling rose to connector and taking down old unserviceable fitting from existing postion for carrying to store, making good disturbed surfaces complete all as specified and as directed.make halonix cat no led inverter batten hlb 08 22 cw inv or equivalent in havells 60 supply and fixingled light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lampconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose to connector, making good disturbed surfaces complete all as specified and as directed.make jaquar cat no lglz01x010xw , orient cat no lbln 10 c sq 61 s & f for recess mounted 2 x 2 square led panel 36 watts, 596 x 596 x 9mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts 270 volts, ac, 50 hz complete all as specified and as directed. make halonix hlfpr22 11 36 cw 37mm, philips rc383b led 4000 psu odwh pir, jaquar lultu1s036xc. 62 s & f for leddown light recess mounted luminare, round / square type 15 wattsas per site requirement with efficiency of 1500 lumens per watt, series of downlighters with low depth round & larger dia, powder coated white finish with drop down pc diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver suitable for office spaces sleek designwhite finish operating voltage 150 v 270 v ac, 50 hz all as specified.make jaquar cat part no. lnep01s015xn / llcn01r01sxn, halonix hldlr31 15cw / hldlr s27 15 cw, philips dn296b led 15s 6500 psu wh. 63 s & f in repairfor decorative wall mounted luminaire with opal glass with nickle finishing wall lamp with e27 lamp holder with and including led bulb 10 / 11 watts complete all as specified and as directed. make jaquar cat part no jnl nkl wlsl 55004e27 , halonix hhw048 08 cf rf or its equivalent in philips. 64 s & f for wall mounted led 06 watts ( ww ) or more, 3000k with good color rendering ( cri>70 ) picture light fitting, 230 volts with durable aluminium housing and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, including taking down old unsv fitting complete all as specified and as directed. make : shakti cat part no szwpfpx003 or luker i 3, limr6 or halonix 65 supply and fixing ceiling fansworking on single phaseinput voltage 140 285 , sweep 1200 mm, power 32 w, 345 rpm , with232 air delivery cmm ( m3 / min ) , complete with compact bldc motor, blades, down rods, electronic regulator and accessories, including making connections with provision of flexible wire 23 / 0.0076 twin core copper conductor from ceiling rose / connector to fan complete all asspecified & as directed. 66 s & f for plastic body exhaust fan, ac single phase, 240 v of size 250 mm sweep with louvers ( as per cat part no 698502of make indo asian or equivalent make bajaj maxima dx / usha crispair ) including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed 67 supply and fix for sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug and socket complete with one mcb sp 20 / 32amps including removal of old unserviceable one complete all as specified and as directed.make scheinder / legrand / l&t / abb 68 supply and fix for wall mounted fan of size 400 mm sweep bee. five star ratedisi marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as including removal of old unsv fan and handed over to store yard of age e / m ( north ) complete all as specified and directed. note : a ) quoted rate is deemed to inclusive of stickering / marking / writing of mes numbers in bottom of ceiling fan as directed by engr in charge. make: bajaj midea bw 2200, usha pentacool, havells v3, atomberg 69 supply and laying 50mm outer dia, double walled corrugated ( dwc ) hdpe duct pipe conforming to is 14930 pt ii with antirodent and non flame propogating properties plete with fittings for cable protection complete all as specified and as directed. 70 supply, lay, joint, test and commissioning of lt under ground cable 1100 volt grade , xlpe insulated and pvc sheathed heavy duty armoured with aluminium conductor , is 7098 i marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drains / culverts or encased in gi pipe including cable glands, lugs jointing material etc complete all as specified and directed. cable of the following size. 71 70 sq mm 3.5 core 72 35 sq mm 3.5 core 73 s & f vertical tpndistribution board in sheet metal enclosure double door 4 way, 415 volts, 50 hz, suitable for flush mounting and surface mounting & provision for fp mccb as incomer up to 160 amps as i / c ( frame1 ) and sp / tp mcbs as outgoing ( modules optium f1+12 ) , with 100 amps copper insulated busbar assembly for each phase, isolated neutral bar, 2 earthbar and cable ties for cable management, ip 43 #ik 09 with metal door including necessary cement work and electrical connections complete all as specified and as directed. 74 supplied and fixed four pole mccb, thermal release range 63 100 amps, rupturing breaking capacity icu at 415v ac 50hz. 30 ( ka ) complete all as specified and as directed 75 supply and fixing amp rating 240v, 10ka c curve miniature circuit breaker ( mcb ) sp 5 to 32 ampand current carrying capacity in the mcb db complete with connection testing and commissioning complete all as per specified and as directed 76 s & f submain wiring with 2 single core ( frls ) pvc insulated unsheathed multistranded flexible copper conductor cable, of 6.0 sqmm and one single core 6.0 sqmm flame retardent low smoke ( frls ) pvc insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per is 694 / 1990 drawn through including concealed in brick / stone masonary pvc conduit and conduit accessories heavy duty isi marked, providing copper cable sockets plate / bottle type of adequate size at termination end of cable point wiring in dbs, switch boards, fittings fixturesall as specified and as directedall as specified and as directedcomplete all as specified andas directed.. note : ( two runs of main copper wire, one run of earth wire cable & pvc conduit shall be measured together as one length ) . 77 s & f submain wiring with 2 single core ( frls ) pvc insulated unsheathed multistranded flexible copper conductor cable, of 4.0 sqmm and one single core 4.0 sqmm flame retardent low smoke ( frls ) pvc insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per is 694 / 1990 drawn through including concealedin brick / stone masonary pvc conduit and conduit accessories heavy duty isi marked, providing copper cable sockets plate / bottle type of adequate size at termination end of cable point wiring in dbs, switch boards, fittings fixturesall as specified and as directedall as specified and as directedcomplete all as specified andas directed.note : ( two runs of main copper wire, one run of earth wire cable & pvc conduit shall be measured together as one length ) . 78 s& fixing lt power distribution panel board with crca sheet and cpri approved, outdoor cubicle type, 415 volts, 50 hz, free floor mounted front and back openable, made out of 3.15 mm thick cold rolled ms sheet of suitable size to accommodate the following items, vermin proof, dust proof, supported on and including ismc 75 x 40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement i.e nuts, bolts, washers, clamps etc, withnaturally air cooled aluminium bus bar 4 strip suitable for 315 amps withdetachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following : 79 ( a ) incoming ( i ) mccb 160 amps 16 ka 4 pole 01 no, 415volt, 50hz ( b ) outgoing ( i ) mccb 100 amps 3 pole, 16 ka 02 nos, 415volt, 50hz 80 ( i ) ryb indication led type 03 nos 81 ( ii ) ammeter digital, 96x96mm, with suitable ratio cts with built in selector switch 1 no 82 ( iii ) volt meter of range 0 500 volts, 96x96mm with built in selector switch 1 no 83 note : all wiring used in panel board should be withfrls grade copper conductor of suitable size. 84 note : 1. performance security: refer condition 22 of special conditions. 2. quoted contract sum shall be arrived at after deducting the amount of credit schedule ( refer schedule of credit in pdf form for quantity, rate and amount etc. ) for old unserviceable materials retrieved from site....

Vasai Virar City Municipal Corporation - Maharashtra

38847512 repairing vehicles owned by the vvcmc for the triennium 2023 24 2024 25 and 2025 26 , nut special , spring compression , ring gear , washer plain , cap, oil filler , seal / o ring , gasket f / pump , ring retaining , shield , elbow, male union , seal , seal rect ring , seal rect ring , screw socket hd cap , gasket , connector tube , kit damper , washer plain , shaft fuel pump , seal , clamp v band , kit height riser ( r800 7 ) , diaphragm f / damper , union male , head c / resistor , head fuel filter , seal kit cyl , plug , switch , service kit , gasket cyl head , flexible hose , harness wiring , harness wiring , solenoid, fuel pump , cleaner, air , element, air cleaner , dipstick , gasket , water pump assy , water pump assy , filter, lubricating oil , gasket hyd pump , clamp, hose , gasket connection , cap filler , bushing , ring , solenoid 24dn01 , belt v ribbed , seal, o ring , seal o ring , seal , spacer fan , spider jaw coupling , pulley alternator , solenoid kit fuel , plug threaded , screw hex hd cap , rod push , ring rect , lever injector , gasket fuelpump , sensor, viscosity , gasket, intake manif , gasket, connection , seal o ring , seal o ring , seal o ring , crosshead valve , hose hump , seal oil , spacer seal , spacer seal , rod push , sensor position ( 3408503 ) , seal oil , sensor temperature , sensor temp , ring retaining , gasket turbo , fuel pump assy , hub jawcoupling , shaft fuel pump drive , stud , gasket f / pump , sensor temp , resistor corroision , resistor corrosion , filter engine oil , head luboilfilter , hub fan , belt fan , motor start , lever camfollower , cooler oil , shut off valve , adapter , idler pulley assy , hose flexible , injection pump , kit water pump , kit water pump , belt v ribbed , v belt , fan belt , fan belt , gasket , dipstick , filter fuel , sensor pressure , sensor pressure , sensor press temp , sensor press temp , sensor pressure , thermostat , sensor pressure , sensor pressure , pulley , pulley fan , tensioner belt , gasket oil pan , element lub oil filter , head oil filter , temp sensor air , solenoid , sensor position , sensor position , module ele control , sensor position , sensor position , tube fuel supply , gasket , turbocharger , turbocharger , turbocharger , relay , pump water , water pump assy , kit water pump , pump water , set, lower eng. gasket ( 20t hyundai cummi , turbocharger assy , seal kit , kit water pump , kit, engine piston , primary element , element, inner , stud, double end , nut, hexagon flange , tube breather , gasket filter , hose plain , starting motor , elbow male adapter , oil drain valve , solenoid assy fuel pump , sensor temperature , temp sensor water , gasket r / lever cvr m11 , seal, o ring , hose flexible , gasket, oil connecti , clamp v band , connection a / intake , gasket , valve shutoff , water separator , gasket , connection , belt v ribbed , gasket support , gasket, turbocharger , screw , nut hexagon flange , nut, regular hexagonal , filter fuel , pulley, crankshaft , screw, hex flange head cap , seal, rectangular ring , seal, rectangular , support fan , belt v ribbed , belt v ribbed ( use sup. by # ) , seal ring , pump water , screw, hex flange head cap , gasket , pulley fan , pulley crankshaft , pulley fan , hose , starting motor , seal o ring , motor starting , sleeve wewar, crankshaft , pulley , adaptor, filter head , clamp hose , belt v, ribbed , o ring , solenoid , bracket solenoid , nut lock , separator, fuel water , head, fuel filter , filter, fuel , seal o ring , filter lub oil ( = lf3806 ) , alternator , pump, fuel transfer , pump, lubricating oil , fuel injection pump , gasket oil drain , cartridge , catridge, lub oil filter , gasket , pump fuel injection , solenoid fuel pump , heater intake air , manifold exh. , belt v ribbed , bracket filter , cooler oil , kit engine piston , connection gasket , alternator , filter fuel , element assy f / filter , sensor pressure , pump fuel transfer , module , sensor position , rocker lever assy , rocker lever assy , rocker lever assy , rocker lever assy , tube fuel drain , union mail , hose plain , hose flexible , hose flexible , harness ecm wiring , hose flexible , kit oil seal , solenoid kit fuel pump , fuel injector , injector ( 4026222po ) , turbocharger , resistor corrosion , pump fuel , pump fuel injection , gasket ( =3039114 ) , fuel injection pump , pressure sw air boost , sw pressure , sensor temperature , set, upper engine gasket , separator, fuelwater , tensioner assy belt , t / c oil drain connection , thermostat , sensor position , hose air charge , lube oil filter , sensor prs temp , injector , screw point , pressure sensor , pressure sensor , sensor position , sensor position , sensor pressure , module ele control , oil seal , thermostat , injector , thermostat , pump assy fuel , sensor temp. , seal kit oil , spacer , gasket , thermostat , gasket , seal kit , support fan , alternator , cylinderservicekit , guard sideshift , bearing lower , radiator cap , cap assy , radiator cap , switch micro , switch micro , switch seat , handle connector, battery , seal oil , element return , gasket, main hyd , oil seal , cushion , spring adjust , pin center , wheelrim outer , wheelrim in , bolt hub , bushing , plate back , shim 0.5 , shim 1.0t , gasket, hyd oil tank , strainer suction , rod , mirror assy back , shim , shim 1.0t , side roller assy, carriage , bearing, steering axle , hose reel assy , bearing, steering linkage , bearing , bearing ball , ball bearing , bearing taper roller , bearing taperroller , ring back up , o ring , o ring , steel plate sm50a8x1500x6000 , steel plate sm50a 22x2550x6500 , ut5570 a dic 164 yellow , ut5570 a ral 7021 black gray , oil_anti freeze , ring back up ( r210lc 7 ) , o ring ( r210lc 7 ) , seal axle, front , seal , hdb pipe assy , hdb pipe assy , pipe assy ( 31n3 92330 ) , pipe assy ( 31n3 92340 ) , pipe assy ( 31n3 92310 ) , hdb pipe assy , pipe assy ( 31n3 92320 ) , hdb pipe assy , hdb arm pipe assy ( 1.67m ) , hdb arm pipe assy , hdb pipe assy , hdb pipe assy , hdb pipe assy , hdb pipe assy , hdb arm pipe assy , hdb arm pipe assy , hdb arm pipe assy , hdb pipe assy , hdb arm pipe ( 2.40m rh ) , hdb arm pipe ( 2.40m lh ) , hdb arm pipe assy ( hdb210 / 230 9 ) , hdb pipe assy ( 2.92m arm ) , hdb arm pipe assy ( 2.1m ) , pipe assy , pipe assy , pipe assy , pipe assy , hdb pipe assy , hdb boom pipe assy , hdb boom pipe assy , hdb boom pipe assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdb hose assy ( 210 9 / 230 9 + qc ) , hdb hose ass’y ( 180 ) , hdb hose ass’y ( 210 ) , hdb hose assy ( hdb210 / 230 + qc ) , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdb hose ass’y , hdq hose protector ( #5*#5 ) ( hdq230 ) , hdq hose protector ( #5*#5 ) ( hdq140 ) , hose assy , hose assy , hose assy , hose assy , hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , hdb hose assy , rock breaker main hose ( 210s demolex ) , hdb hose assy , hdb hose assy ( hdb210 / 230 9 ) , hdb hose assy , hdb hose assy , hdb hose assy , s / p hose ( 3#*903# ) , hdb hose assy orfs, thd ( 0x0 ) , hdb stop valve ( o ring ) , hdb stop valve , valve, stop , valve, stop , valve, stop , hdb stop valve lh , hdb stop valve rh , wheel steering , knob kit, stee column , cap, union , cap, union , hdb cap, union , hdb cap, union , hdb plug, choke , hdb plug, choke , hdb plug, hollow , hdb plug, hollow , hdq hex. bolt socket plug ( hdq140 / 230 ) , hdb plug, hex. socket , hdb plug, hex. socket , hdb plug, hex. socket , hdb plug, hex. socket , hdb plug, hex. socket ( hdb 140 9 ) , hdb plug, hex. socket , hdb plug, hex. socket ( hdb 210 / 230 ) , hdb plug, hex. socket , hdb plug , hdb plug, hex. socket , hdb plug, hex. socket , hdb plug, hex. socket , hdb grease nipple , grease nipple , hdb elbow, 90 lock nut , hdb 90 elbow ( lock nut ) , hdb elbow, 90 lock nut , hdb elbow, 45 lock nut , hdb elbow, 45 lock nut , hdb connector, o ring , hdb connector ( o ring ) , hdb connector , hdb connector, o ring , hdb connector, o ring , hdb connector, o ring , hdb connector, o ring , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb plug, hose , plug, hose ( 3# ) , hdb plug, hose , hdb plug, hose , hdb plug, hose , hdb adapter , bearing , hdb hose joint block , hdb block ( hose joint ) , hdb n2 recharge kit without n2 case 210 , hdb n2 recharge kit without n2 case 230 , hdb coupling , hdb screw coupling , hdb o ring , hdb o ring , o ring , hdb o ring ( unf9 / 16 ) , o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring ( p ) p34 , hdb o ring , hdb o ring , hdb o ring , o ring , hdb o ring , o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb o ring , hdb u packing , hdb u parking , hdb u packing , hdb u packing , hdb u packing , hdb seal, dust , hdb seal, dust , hdb seal, dust , hdb seal, dust , hdb seal, dust , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, buffer , hdb ring, quad , hdb ring, quad , hdb quad ring , hdb quad ring , hdb quad ring , hdb seal, step , hdb seal, step , hdb seal, step , hdb seal, step , hdb seal, step , bush, du , hdb solenoid , hdq pilot check valve ( hdq140 / 230 ) , hdb valve, port relief , hdb clamp, stop valve , hdb clamp, pipe upper , hdb clamp, pipe upper , hdb bracket clamp , hdb sol v / v bracket , hdb side bolt set , hdb bolt, hex. , hdb bolt, hex. , hdb bolt, hex. , hdb bolt, hex , hdb bolt hex ( 10.9 ) , hdb bolt hex ( 10.9 ) , hdb bolt hex ( 10.9 ) , bolt, hex. , hdb bolt, hex. , hdq bolt, hex. ( hdq140 ) , hdb bolt, hex. , hdq bolt, hex. ( hdq230 ) , hdb bolt, hex. , hdb bolt, hex. , bolt , hdb bolt, hex , bolt, hex.b210 / 230ts , hdb bolt, hex , hdb bolt, hex , hdb bolt, socket , hdb bolt, socket , bolt, socket b145 , bolt, socket b145 , hdb bolt, socket , hdb bolt, socket , bolt, socket b235 , hdb bolt, socket , hdb bolt socket , hdb bolt, socket , hdb bolt, socket , hdb bolt, socket , hdb bolt socket , hdb bolt socket , hdb bolt, socket , hdb bolt, socket , hdb bolt, socket , hdb bolt, socket , hdb bolt socket , hdb bolt, socket , hdb bolt, socket , hdb bolt, hex , hdb bolt, hex , hdb bolt, hex , hdb bolt, hex , hdb nut, hex. , hdq nut, hex. ( hdq140 / 230 ) , hdb nut, hex. , hdb nut, hex. , hdb nut, cap hex. , hdb nut, hex. nylock , hdb nut, hex. nylock , hdb nut, hex. nylock , hdb nut, hex. nylock , nut, hex. ( slotted ) , hdb washer spring , hdb spring washer , hdb washer, spring , hdb washer spring h / t , washer, spring , hdb washer, spring , hdb washer, spring , hdb washer, spring , hdb washer, spring , hdb washer, pln. , hdb washer, pln. , washer, plain , hdb washer, dish , washer, nord lock , hdb washer, nord lock , hdb washer, nord lock , hdb washer, nord lock , hdb switch, breaker toggle , upper damper , hdb damper, upper , hdb damper, upper , hdb damper, upper , hdb damper, upper , hdb damper, bottom , hdb plug, screw+rubber , hdb plug, screw+rubber , hdb plug, screw+rubber , hdb plug, screw+rubber , hdb diaphragm , hdb diaphragm , hdb auto grease unit , hdb heli coil , heli coil b215 / b235 , hdb heli coil , hdb heli coil , hdb heli coil , hdb heli coil , o ring , o ring , o ring , o ring , o ring , ring, snap , hdq ring, snap ( hdq140 / 230 ) , hdq ring, snap ( hdq140 ) , hdq ring, snap ( hdq230 ) , pin, split , hdq pin, spring ( hdq230 ) , hdq pin, snap ( r pin ) ( hdq140 ) , hdq pin, snap r ( hdq 230 ) , coil , motor hyd , hdb n2 case ( l ) , hdb n2 case ( s ) , valve anti shock , cap sealing , cap sealing , cap sealing , cap sealing , aeb starter , clamp hose , tube spiral , o ring , o ring , o ring , bushing , v belt , o ring , o ring inj pump , o ring , o ring , needle bearing , oil seal , shim , b / up ring p18 anillo , ring back up , gasket plug chanber , pump assy priming , gasket cover , clamp t bolt , clamp , o ring , o ring, mcv , o ring, mcv , o ring, m.c.v , cap spring return , j bearing assy , j / bearing assy , j / bearing assy , j / bearing assy ( =03075885 ) , j / bearing assy , u / joint assy , u / joint assy , nipple grease ( =02060843 ) , antifreezer diluted ( 3l ) , nipple grease , nut self locking , bolt , bolt , feeding pump, injec.pump , coupling injection pump , lock nut , nut , seal kit , bolt , bolt washer assy ( 6*25 ) , bolt washer , stud , stud ( m10 ) , filter eng fuel , gasket , bolt w / washer , bolt washer , bolt washer , bolt w / washer , bolt , bolt 10*45 , bolt , bolt semsoil pan , generator assy , element, plastic only , hub , insert , insert ( inserto ) , bolt , cable push / pull ( l=180inch ) , filter fuel , filter fuel , oil filter , eng oil filter , filter lub oil , filter fuel w / s , eng fuel filter , filter fuel, engine , element c / resistor , control assy , housing , element a / c inner , hose fuel , hose , v belt , hose , bracket cable , fan , hose vent , clamp t bolt , clamp t bolt 113 121 , clamp t bolt 122 130 , clamp t bolt 131 139 , nut wing , clamp, exhaust pipe , receiver drier assy , cable push pull , cable , hose heater , hose, ac , bracket rh, fr , bracket lh, fr , mount wa rh, eng , mount wa lh, eng , hose breather , hose breather , hose breather , fan engine , coupling assy , coupling , bolt clamp , hub , hub, pump mutg , element , element coupling , insert a , insert a , insert coupling ( a ) , insert r , insert coupling ( r ) , coupling assy , coupling , coupling , pipe flexible , clamp exhaust pipe , v belt , hose , shroud fan , hose upper, radiator , hose engine in , rod , gasket , hose , rod assy , hose inlet , hose fuel , lever wa , bracket lh, rr , resilient , clamp exhaust pipe , hose outlet , hose assy , hose assy , fan 24 / 9 blade , resilient , cap pressure , cock darin , hose drain , hose fuel , hose heater , hose heater , hose drain , hose drain , spacer , coupling assy , coupling assy , element primary , element secondary , nut wing plastic lg w / rubber seal , nut wing s / rubber seal , clamp band , cap, radiator reservoir , water separator , rod end , compressor assy , condenser assy , condenser assy , tank reservoir , sensor reservior , hose assy , bracket muffler , plate clamp , hose assy , bracket cable , speed lever , bolt hex , hose fuel , valve fuel cut , strainer, fuel , hose, fuel , hose, fuel , hose fuel , cooling fan , gasket , precleaner , sensor air cleaner , rubber mounting , element primary , element safety ( in ) , pedal accel , filter safety , element assy inner , filter primary , element a / c outer , element assy outer , hose air cleaner , hose upper , hose cac , hose , hose lower , lower hose , hose cac in , hose , pipe exhaust , pipe wa exhaust , gasket, fuel sys , belt aircon , element a / c outer , element a / c inner , spring return , hose air cleaner , hose radiator ( up ) , hose radiator ( low ) , hoseassy fuel , eng fuel filter assy , gasket, fuel sys , mount , mount rubber, eng mtg , filter bulkhead, fuel sys , element primary , element safety , rad & o / c ( t ) assy , radiator , capassy , cap fuel tank , clip hose , hose air cleaner , hose air cleaner , cable accel , hose air cleaner , hose radiator ( up ) , hose radiator ( low ) , mount rubber, eng mtg , cooling fan , tampa bocal tanque combustivel empilhade , clamp , housing , precleaner assy , element assy primary , element assy safety , filter aircon in , control assy , condenser assy , filter inlet , filter fresh , sensor temp , core assy evap , actuator assy intake , sensor incar , aircleaner assy , element assy primary , element assy safety , hose intake a , hose intake b , muffler sub assy , hose lower , hose upper , hose cac , hose cac , hose cac , hose cac , precleaner assy , coupling assy , coupling , coupling assy , air filter, outer , air filter, inner , clamp , clamp assy , valve , gasket , hose over flow , element set a / cleaner , gasket , hose heater , aircon belt , hose rubber , element primary ( out ) , element primary ( out ) , element safety ( in ) , element safety ( in ) , fan cooling , radiator complete , oil cooler complete , charge air cooler , hose heater , hose assy suction , hose assy return , hose radiator ( up ) , connector hose , hose radiator ( out ) , hose , hose , hose charged air , clamp torque retention , clamp seal , hose suction , hose discharge , washer mount , washer , valve heater , hose heater , hose heater , hose assy suction , hose assy suction , fuel cap assy , hose assy return , pre filter assy , element assy f / filter , elbow 90 , hose assy fuel line , hose assy fuel line , hose rubber , hose rubber , fan cooling , fan motor , fan cooling , fan cooling , charged air cooler ( hl770 7 ) , hyd oil cooler assy , radiator assy , hose rubber , cooler t / mission , t / m oil cooler assy , air cleaner assy , hose aircleaner , hose aircleaner , pipe wa ( hl770 7 ) , pipe ( hl770 7 ) , hose aircleaner , hose aircleaner , hose air cleaner , clamp hose , clamp hose , clamp hose , clamp hose , clamp hose , clamp, air intake , clamp hose , clamp band, t bolt , clamp , clamp hose , clamp band, t bolt , flex tube , bracket wa , bracket wa lh , screen t / charger , insulator , muffler assy , muffler assy , pipe exhaust , insulator , pipe wa , insulator , resistor corroision , fuel filter , element assy f / filter , mount rubber , mount rubber , discharge hose , hose ( a ) liquid , hose ( b ) liquid , hose suction , hose suction , control assy , control assy , hose return , hose liquid , hose discharge , hose discharge , pipe assy hyd , hose assy , hose assy , motor fan , t / m cooler assy , charged air cooler , hose rubber , hose rubber , radiator assy ( 760 7a ) , hyd oil cooler assy , fan motor ( 760 7a ) , hose air cleaner , hose air cleaner , hose charged air , bellows pipe assy , pipe wa , insulator , fuel filter , hose ( a ) liquid , hose ( b ) liquid , hose heater , condenser assy , hose discharge , hose suction , bracket wa lh , bracket wa rh , fuel filter / ws assy , head filter , element assy , bowl assy w knob , fan motor one direction , hose rubber , hose charged air , clamp t / retention , cap air cleaner , pipe wa exhaust , insulator , filter fuel , hose ( b ) liquid , thermal switch , fan & motor assy , condenser ( sl ) , eng fuel filter , liquid hose ( a ) , t / m cooler assy ( 780 7a ) , fan cooling , hose rubber , hose rubber , u bolt , hose , discharge hose , liquid hose ( a ) , liquid hose ( b ) , suction hose , v belt , seal clamp assy , air cleaner cap , clamp assy , separator water , hose inlet, radiator , hose outlet, radiator , hose outlet, radiator , reservior tank , hose over flow , cap pressure , cable lever , v belt , coupling assy , coupling rubber , hose , hose , gasket , pre cleaning , bracket , resilient , resilient , fan cooling , washer overload , fan cooling , engine assy , bracket , mount engine , coupling assy , hub coupling , element 25h , insert a 25h , insert r 25h , air cleaner assy , hose , hose , hose , hose , clamp a / cleaner , body air cleaner , element a / cleaner ( in ) , element a / cleaner ( out ) , cover , valve vacuator , cap nipple , clamp resonator , bracket , pipe wa , clamp seal , muffler assy , bracket muffler , hose , hose , hose assy , hose , reservoir tank , tank reservoir , radiator total a , hose assy , hose assy , hose assy , cable , cable lever , cable pedal , rod engine , spring , accel link assy , cable pedal , filter circulate , v belt , hose suction , condenser assy , v belt , actuator , relay , o ring , o ring , o ring , o ring , o ring , o ring , compressor assy , hose suction , washer overload , stopper nut , coupling assy , engine hydraulic coupling element , washer plate , mount rubber , mount rubber, eng mtg ( r35z 7 &9 ) , resilient , aircleaner , hose , clamp , a / c element ( in ) , element a / c inner , a / c element ( out ) , element a / c outer , valve intake , muffler assy , hose air , cooler assy oil , hose rubber / up , hose rubber / low , hose , hose fuel , condenser assy , dryer receiver , filter air , v belt ( air con ) , compressor assy , coupling assly , engine hydraulic coupling element , hose rad upper , hose rad lower , screen , engine assy , bracket , bracket comp mount , bracket , fan cooling , fan , fan , bracket , bracket , engine assy 4r1040, 76 hp , fan cooling , cooling fan , washer overload , coupling assy , hub spline , pump housing , hose , air cleaner assyr80 7 ( 4h.1198.10.0.00 ) , safety element ( 4h.1198.02.0.00 ) , primary element ( 4h.1198.01.0.00 ) , hose , hose , muffler sub assy , muffler wa , pipe w.a , seal clamp , muffler w.a , radiator assy , oil cooler assy , net wire , screen assy , bracket , screen plate , hose , bracket , screen , cooler assy oil , radiator total assy , radiator assay , oil cooler , shroud assy radiator , frame assay , fan guard , hose , hose , screen , hose assy , hose assy , hose drain , hose drain , hose assy , hose assy , elbow 90 , cable pull , hose liquid ( b ) , hose suction , hose suction , v belt , pulley tension , hose discharge , hose discharge , elbow , hose ( a ) liquid , hose fuel r80 , hose fuel r8 , clamp t bolt ( 53mm 59mm ) , hose , hose , radiator total assy r 80 , clamp , engine assy ( s4k dt ) , bracket front , bracket rear , fan ring , engine & comp bracket , engine assy , bracket , bracket , bracket , fan cooling ( r110 7 ) , fan cooling , hub , coupling assy , hose air cleaner , hose , hose , hose , muffler wa , bracket muffler , connector pipe , muffler assy , muffler wa , pipe exhaust , radiator assy , oil cooler assy , hose rad, upper , hose rad, low , wire net , rod assy , radiator total assy , radiator assy , rdiator assy , oil cooler assy , cooler assy oil , hose , hose coolant , lever speed , bracket , pulley air con , hose fuel r110 , hose fuel r110 , hose fuel r110 , clamp t bolt ( r110 7 ) , clamp hose ( 125 mm ) , air con pulley ( r110 7 ) , engine & comp bkt , hose radiator , clamp ( p clamp ) , air con pulley r140lc 9 , roc assy , bracket front , bracket rear , washer mount , nut stopper , nut stopper , engine & comp bracket , drain valve engine oil , engine assy , hose ( b ) air cleaner , air cleaner assy , connector pipe , muffler wa , bracket , bracket , fan guard , hose rad ( low ) , hose rad ( upper ) , rod rad mtg ( rh ) , rod rad mtg ( lh ) , shroud assy , rubber pad , hose , charge air cooler , hose cac , oil cooler assy , radiator assy , hose rubber low , hose cac , screen assy , u bolt , tank reservoir , tank reservoir , cap , hose fuel , hose fuel , hose fuel , bracket cable , filter lub oil , aircon & heater assy , hose ( a ) liquid , hose ( b ) liquid , hose suction , hose suction , hose discharge , hose discharge , v belt , v belt , v belt , bracket front , bracket rear , bracket comp , housing pump mutg , hose ( b ) air cleaner , hose ( a ) engine , muffler wa , oil cooler assy , intercooler assy , radiator , hose rad ( low ) , hose rad ( upper ) , hose charge air , hose charge air , hose charge air , hose assy fuel , hose fuel , lever speed , hose ( b ) liquid , pully air con , connector hear v / v , bracket front , bracket rr , bracket , engine , stopper nut , stopper nut , fan ring , fan , fan , fan, engine , engine assy , engine assy ( r210 7v ) , engine assy , cooling fan , cooling fan , engine assy , rubber mount , rubber mount , mount rubber , rubber mount, rr , resilient , housing , rubber mount , rubber mount , rubber mount , mount rubber, eng mtg , rubber mount , coupling , hub spline , hose air intake , pipe air intake , hose air intake , hose , ring support , grill , hose air intake , air cleaner assy , body air cleaner , cap wa air cleaner , cover switch , clamp t bolt , clamp t bolt , clamp t / bolt , clamp t / bolt , clamp t bolt , clamp band, t bolt , clamp band, t bolt , clamp band, t bolt , clamp t / bolt , air cleaner sub assy ( r220lc 7 ) , hose intake ( b ) , hose intake ( a ) , hose air intake , pipe , hose air intake , precleaner , element primary , element safety , element assy safety , element primary , cover assy s / cowl , vaccum valve , pipe , seal clamp assy , seal clamp assy , mufler , pipe , muffler sub assy , muffler sub assy , muffler sub assy ( 11n6 32211 ) , muffler assy , muffler , bracket mount, exh , bracket muffler ( r210 7v ) , muffler sub assy , mufflerassy , muffler , muffler , radiator total assy , radiator total assy , radiator assy , radiator , oil cooler assy , oil cooler assy , shroud assy , cover , bracket rad , hose , hose , wire net , sponge rubber , wire net , fan guard , bracket cond. ( r220lc 7 ) , radiator total assy , cooler assy oil , hose upper , hose lower , radiator total assy , ring back up , radiator , oil cooler assy , cooler assy oil , shroud assy , fan guard , wirenet, radiator , sponge, rad , wirenet, radiator , pipe cac , pipe cac , radiator ( >11n6 43021 ) , bolt u , radiator total assy , radiator total assy , stay , stay , stay , stay fr , stay , stay rr , radiator total assy , connector , bracket cable , lever speed , lever emergency , bracket , aircon & heater unit , aircon & heater unit , aircon & heater unit , control assy , control assy , compressor assy , receiver drier , hosed discharge , hose liquid / a , hose liquid / b , suction hose , pulley idle , bracket r / drier , receiver drier assy , hose discharge , v belt , filter rec , control assy ( digital reading ) , controlassy , cover control , fan&motor assy , fan & motor assy, air con , motor act vent , motor act temp , motor act intake , resistor assy , air filter fresh , air filter re ( =am88000300 2 ) , heater core , evap core assy , evap core assy , evap core assy , evap core assy , expansion valve , motor act foot / def , relay ( =a810000101 3 ) , wiring assy , decal a / c & heater , air con assy , air con & heater assy , air con unit [ t ] , aircon unit , dis hose assy , suc hose ass;y , v belt , bracket control , bracket resistor , air con & heater unit , filter rec , pulley air con , hose liquid / a , fan belt , hoses silicon , silicon hose , t bolt clamp , hoses silicon , pipe pre cleaner , air cleaner assly ( 8250588 ) , air filter primary , cable stop , hose fuel , pre cleaner assly , muffler sub assy ( 20t ) , bracket , hose eng oil drain , coupler assy , element , hub spline , insert a , insert r , screw clamp , hose , hose , oil cooler assy , hose , hose , hose , hose , hose , hose assy , hose assy , hose assy , washer , v belt , fan cooling ( ring type ) , engine oil d / valve , stopper nut , bracket rh , hose breather , fan ( tier 2 ) , fan , engine assy ( d6ac c ) , nut stopper , coupling assy , air cleaner assy , hose , hose , housing , precleaner , precleaner , hose , air cleaner sub assy , air cleaner assy , cap wa , element outer , element inner , hose , hose , pipe , hose , hose , hose , hose air cleaner , hose , tail pipe , clamp band , clamp band, exh sys , hose , clamp seal , pipe exhaust , bracket muffler , muffler sub assy , bracket lift , bracket lift , hose , hose a , hose b , radiator assy , oil cooler assy , oil cooler assy ( cu ) , oil cooler assy ( alu ) , tank reservoir , tank reservoir , tank reservoir , clamp reservoir tank , hose , hose , radiator assy , hose , hose , hose , hose , oil cooler , hose cac , intercooler assy , intercooler assy , intercooler assy , intercooler assy , radiator , bracket , pipe wa , pipe wa , hose , hyd oil cooler , fan , radiator assy , oil cooler assy , hose , cap assy , elbow 90 / orfs , hose , hose assy , hose assy , hose assy , hose fuel , bracket , hose fuel line , hose fuel line , cable throttle , cable throttle , cable throttle , bracket , lever rod , lever cable , lever throttle , rod assy , cable , pedal asy , filter fule , filter engine oil , head, pre filter , hose ( a ) liquid , hose ( b ) liquid , pulley , hose suction , hose suction , heater assy , compressor assy , bracket , compressor bracket , hose heater , pump fuel , filter fuel , hose fuel line , fuse box p / heater , hose discharge , hose discharge , hose suction , hose suction , valve oil drain , valve , connector drain hose , hose breather , engine assy , pipe connect , hose , oil cooler ( 320 7 / a ) , hose , oil cooler assy , hose assy , lever throttle , bracket , hose fuel_r340 7 , hose fuel_r340 7 , plate , bracket wa , nut stopper , fan , engine assy , fan cooling , fan cooling , fan , spacer , bracket lift , hose , hose , bracket pipe , hose , hose , muffler assy , pipe exhaust , radiator assy , intercooler assy , intercooler assy , hose , radiator , bolt u , sponge , oil cooler assly , cap pressure , screen , radiator assy , radiator total assy , radiator assy , hose fuel , connector , connector , fuel filter , engine oil filter , corrosionresistor , fuel filter w / s assy , pre filter assy , head filter , heater fuel , element fuel filter w / s assy , element assy , bowl clear , o ring , sensor , o ring , element, fuel filter , hose ( a ) liquid , bracket wa rear , fan cooling ( 9ea ) , fan cooling , fan , cooling fan , drain valve eng oil , cooling fan , engine assy , engine assy , coupling assy , coupling assy , hub coupling , element coupling , insert coupling ( a ) , insert coupling ( r ) , element coupling , element ( coupling ) , hose , hose , precleaner , precleaner , air cleaner sub assy , housing air cleaner , element outer , element a / c inner , hose , bracket , muffler , clamp band , muffler , muffler sub assy , muffler sub assy , bracket , screen , hose , pipe b , pipe w.a a , wire net , sponge , clamp reservoir tank , charge air cooler , charge air cooler , air cooler charge , fan guard , sponge , sponge , wrench filter, 300mm , hose , oil cooler hyd , radiator total assy , radiator , shroud assy , hose , screen assy , bracket , radiator total assy , radiator assy , oil cooler ( heavy duty ) , oil coller assy ( bar plate ) , oil cooler hyd , hose assy , hose assy , hose assy , fuel filter , oil filter , corrosion resistor , filter corrosion resistor , pre filter assy , bowl assy w / heater , drain knob, gasket , discharge hose , discharge hose assy , suction hose , suction hose assy , bracket comp.mtg , fan & shroud assy , condenser assy , condenser assy, air con , hose ( a ) liquid , hose discharge , fan, cooling , washer mount , drain valve eng oil , coupler assy , element , hose intake ( a ) , hose intake ( b ) , air cleaner assy , element safety , element primary , hose intake ( a ) , muffler sub assy , muffler wa , muffler wa , hose , hose upper , hose lower , hose radiator ( low ) , fan guard , cap radiator , hose , hose fuel , hose assy return , hose fuel , hose fuel , elbow 90, orfs , filter, fuel , filter, engine oil , filter, coolant , compressor , hose liquid ( a ) , hose assy suction , hose discharge , engine assy 4r1040t4 105hp , indicator , hose air intake , hose , hose aircleaner , reservior tank , clamp , clamp , clamp , clamp , cooler assy oil , radiator total assy , radiator assy ( r140lc 9 ) , hose , hose , screen , valve fuel cut , discharge hose assy , liquid hose , suction hose , hose air intake , hose , bracket comp , spacer , hose , hose , pipe wa , hose , radiator assy r140 , fan clutch , fan clutch assy , cooling fan , air cleaner assy , hose aircleaner ( a ) , hose air cleaner , charge air cooler , oil cooler assy , hose radiator ( low ) , radiator assy , hose fuel , connector , hose fuel , compressor assy , condenser , condenser assy , compressor , filter rec , hose discharge , control assy , filter ( aircon ) , expansion valve, air con , evap core assy , control assy , air cleaner assy , element assy safety , element a / c inner , element assy outer , vaccum valve ( r510 for donlson ) , clamp band, air intake , rain cap assy , aircleaner assy , a / c element ( in ) , a / c element ( out ) , fan cooling , hose aircleaner ( b ) , hose air cleaner , hose fuel line , hose fuel , nut , hose aircleaner ( a ) , rubber seal , hose intake ( b ) , oil cooler hyd , radiator assy , hose upper , hose lower , hose radiator ( low ) , eng fuel filter , pipe connect , hose , hose overflow , rubber eng. mtg , nut , nut stopper , bolt hex , bolt hex , bolt hex , rubber eng mtg , spacer , plate adapter , hose overflow , radiator assy , cooler assy oil , cooler charge air , hose assy return , connector , hose fuel line , hose fuel line , hose fuel line , hose fuel , bracket comp. mtg , hose suction , nut , rubber eng mtg , washer , filter assy fuel , bowl assy , eng fuel filter , element outer ( old ) , element outer ( new ) , element inner ( new ) , hose , hose fuel , plug magnetic , tool kit assy , seal , fuel cap assy , lower hose , upper hose , speed control cable , heater valve, air con , hose radiator ( low ) , pull cable assy , washer , pin, piston , gasket, thermostat , gasket thermostat , thermostat , switch, oil pressur , seal htc95, 115, 10 , seal valve stem , filter oil ( ep ) , gasket, ( non asb. ) , gasket, cyl. head , main bearing us=0.25 , bearing, thrust .25os , gasket bonnet , gasket suc manifold , gasket , gear ring , piston w / ring , piston w / ring os=.25 , bearing pin u.s=0.25 , o ring p20 , pump, cooling water , gasket, cw p , pulley fan , pulley fan , gasket, case , pump assy, full feed , starter ( 2.3kw , ring set piston, engine , ring set o.s=0.25 , nozzle , pipe no.1, f.inject. , pipe no.2, f.inject. , pipe no.3, f.inject. , pipe no.4, f.inject. , flywheel assy , solenoid, stop , fan, cooling , v belt , hose air vent , gasket , belt a type, 44 , nut 10 , nut ( 16 ) , nut ( 10 ) , nut , nut flange , washer spring , washer spring , backing spring , hub , coupling assy , element , insert a , insert r , hose return , cable accelerator , hose aircleaner , hose radiator in , hose radiator out , hose radiator out , ratchet type spanner for lock nut , pin dowel , pin spring ( 6x12 ) , key woodruff ( 5*19 ) , key wood ruff , ring snap , ring snap , clamp ( 14711 48003 ) , clamp hose , clamp hose , housing , damper assy , bolt hex , sight gauge assy , clamp t bolt 140 148 , v belt , rubber mount , washer rebound , clamp assy, air intake , clamp hose , rubber mount , clamp band , hose fuel , cable pull , hose air cleaner , hose air cleaner , hose air cooler ( in ) , hose air cooler ( out ) , hose air cooler ( in ) , clamp tube , hose fuel , hose fuel , hose discharge , control assy , hose liquid ( a ) , valve heater , valve heater , element outer , element inner , rubber , gasket , resilient , precleaner , connector hose , muffler sub assy , radiator assy , cooler assy oil , shroud assy , plate injcetion pump , plate, inj pump , sensor temp , nipple grease , cap sealing , cap sealing , cap sealing , cap sealing ( 25 ) , sedimenter assy , cable accel , hose radiator ( up ) , hose radiator ( low ) , hose inlet , hose outlet , water muffler 3t , engine assy , bearing ball , ut5570 b curing agent , o ring , o ring , o ring 45 , o ring , o ring , o ring , eng fuel filter , gasket , gasket , gasket , gasket , gasket , gasket , gasket , gasket , bumper door , fuel filetr , hygen forklift brake oil 1l , hygen forklift brake oil 1l , hygen coolant ( 5l ) , hygen coolant ( 10l ) , hygen coolant ( 205l ) , brake oil ( 1l ) , plastic box ( blue ) , hose air cleaner , hose air cleaner , hose air cleaner , hose ( up ) , hose ( low ) , fan cooling , hose radiator ( up ) , filter assy eng fuel , sensor air flow , bracket for mounting accelerator & stop , set screwm10x1.5x208.8 , plain machined washerm10 , set screw m6x1x12 8.8 , plain machined washer m6 , pull type accelerator lever , adaptor for l.o.p.switch ( m12x1.5 0.125 , copper washer ( 12x18 ) , air cleaner assembly , safety element for kfa 01 7221 , primary element for kfa 01 7221 , worm drive hose clip ( 48 mm ) , breather pipe , clip for breather pipe , set screw m8x1.25x20 8.8 , plain machined washer m8 , bracket , tension spring , nut m10x1.5 gr.8 , set screw m6x1x14 8.8 , nut m6x1 gr.8 , spring holding bolt modified, ltk , camshaft subassly , cam shaft gear , thrust washer for cam shaft , pin , crankcase assly.without bearings , sealing cap , sealing cap. ( 40 din 443 ) , sealing cap , crank shaft plug aluminium , washer for alu.plug. , bolt for mb cap ( hex head ) m14x2x128 , special washer for m14 bolt , precoated screw plug , copper washer ( 20x26 ) , slotted pin , core plug , blanking plate for cam bore , joint for cam bore blanking plate , set screw m8x1.25x25 8.8 , dipstick guide , precoated plug ( for oil gallery ) , copper washer ( 10x16 ) , main bearing half ( standard ) , plug ( m14x1.5 ) , copper washer ( 14x20 ) , dowel , spring dowel pin , oil spray nozzle ( modified ) , sub. assembly of special banjo bolt , plug for dip stick hole , crankshaft assembly , washer , socket head bolt m12x1.75x60 10.9 , crankshaft gear , deflector for oil seal , dowel pin 8x25 , crankshaft pulley with poly v groove 172 , bolt for crank pulley , mud slinger ( for p92 ) , set screwm6x1x208.8 , cylinder head assly complete. , valve seal , inlet & exhaust valve pair , cup for valve spring. , valve spring , valve cup , valve collet ( 3 groove ) , wire snap ring , copper washer ( 18x22 ) , copper washer ( 26x32 ) , sealing cap , stud m8 x1.25 x 65 mm 8.8 grade , spring washer m8 , nut m8x1.25 gr.8.8 , stud m10x1.5x75 8.8 , stud m10x1.5x50 8.8 , copper washer ( 12x16 ) , joint for water outlet manifold , bolt for cylinder head. , washer , gasket for cyl. head ( thickness 1.22 ) , gasket ( for cylinder head ) 1.10 thk. , cylinder with `o’ ring , o ring ( for cyl.liner ) , o ring for cylinder liner ( viton materia , delivery body assembly , delivery body , joint for delivery body , delivery tube , ‘o’ ring ( for delivery tube ) , dipstick assembly , adaptor for dipstick ( bar ) , crank case foot starter side ( 285 mm ) , crank case foot fuel pump side ( 285 mm ) , set screw m12x1.75x35 8.8 , exhaust manifold for k 26 turbocharger , spacer ( for ext.manifold ) , socket head cap bolt m8x60 long , stud m8x1.25x025 8.8 , nut ( ss ) m8x1.25 , s.s. joint for exhaust manifold , assembly flywheel for 11 clutch , starter ring ha , adaptor on flywheel for hhi , set screw m10x1.5x30 8.8 , bolt for flywheel ( m10x35 long ) , flywheel hosuing sae 3, 130 mm , hollow dowel ( 16 dia ) , set bolt m10x30 10.9 , washer , blanking plate ( for flywheel housing ) , cover for fly wheel hsg , set screw m8x1.25x16 8.8 , front cover for jcb , set bolt m8x1.25x80 8.8 , set bolt m8x1.25x30 8.8 , adaptor ( for tachodrive ) , cup for spring , spring for cup , copper washer ( 24x29 ) , drain plug ( f ) , copper washer ( 18x24 ) , gear end oil seal ( 80x105x12 ) , adaptor for tacho drive unit , joint for tacho drive unit adaptor , timing pointer , oil deflector plate , cover for fuel pump gear , set bolt m8x1.25x35 8.8 , joint for fuel pump grar cover , spacer for air cleaner bracket ( od 20x i , spacer for air cleaner bracket ( od 20x i , mounting plate for fuel filter , plain machined washer m12 , 1.1 ltr duel fuel filter w / o overflow va , o ring , banjo bolt m14x1.5 , set screw m12x1.75x40 8.8 , fuel injection pump suitable , joint for fuel pump ( non asbestos ) , l.o.supply hose ( fip ) m10 banjo ends x 2 , special banjo bolt ( l.o.supply to pump ) , copper washer ( 10x14 ) , banjo bolt m14x1.5 , banjo bolt with strainer ( 2 443 456 900 ) , fuel pipe ( m14xm14 banjo with 60 deg, 37 , fule pipe fule pump to fuel filter ( 47 , fuel pump gear ( finish ) , hub for fuel pump gear ( finish ) , set screw m8x1.25x25 8.8 , washer for fuel pump gear , gear casing machining cost reduction for , joint for gear cover , precoated stud ( for fuel pump mounting ) , plain machined washer m10 , nut – m10x1.5 gr.8 , dowel for gear casing , set bolt m8x1.25x70 8.8 , high pressure pipe set , rubber sleeve , hose tail connection ( s / f m14 banjo ) , assembly of injector of cmvr stage ii ( e , washer for inj. ( 2439999032 ) , injector yoke. , bush for injector , o ring for nozzle , inlet manifold ( top & few opening ) , joint for air inlet manifold , set bolt m8x1.25x120 8.8 , set bolt m8x1.25x65 8.8 , copper washer ( 20x24 ) , joint ( for air pipe ) , set screw m8x1.25x30 8.8 , joint for blanking plate 4h.346.06 , blanking plate for inlet manifold , air pipe turbocharger to inlet manifold , rubber hose ( turbo air outlet ) , intermediate gear support , retaining plate ( for int.gear ) , assly of intermediate gear & bush , bush for intermediate gear , thrust washer , joint s s for adaptor ring , hose for brather pipe 4rt , worm drive hose clip ( 35 mm ) , shaft for lub oil pump ( intermediate gea , hard washer ( for int. gear ) , sub.assly.of l.o.pump int.gear and bush. , set bolt m8x1.25x75 8.8 , leak off pipe assembly , banjo bolt , mico copper washer for leak off pipe , lifting hook , plain machined washer , lub oil cooler and header assembly , adaptor for spin on filter , headless pipe plug 1 / 2 14 nptf , set bolt m8x1.25x50 8.8 , set bolt m8x1.25x90 8.8 , socket head screw m8x1.25x35 8.8 , joint for lub oil cooler ( non asbestos g , lub oil cooler ( 8 plates ) , spin on filter for lubricating oil , joint for header , lube.oil pump assembly. , counter sunk socket head screw. , o ring l.o.pump ( 1.57x65, 21508 ) , relief valve , split cotter pin 1 / 8x1 1 / 2 , lub oil sump 35 deg inclination , joint for lub oil sump , baffle plate , alternator sa28 24v 55a , magnetic pick up with amp ( tyco ) connecto , flywheel end foot ( for ltk ) , flywheel end foot ( for ltk ) , bracket for alternator mounting. , spl.plain m / ced washer , alternator pulley with poly v groove 90 , locating bolt 80 mm ( for eye bolt ) , locating bolt 60 mm ( for alternator clam , swivel piece , eye bolt ( 190mm ) , spl. plain washer m12 , special plainwasher m10 , spacer 11 i.d. x 24 o.d. x 25.5 l , spacer 60mm for fan mounting , stud m8x1.25x85 8.8 , plate ( with rubber moulding ) , oil seal hsg. ( f.w.e. ) , oil seal ( 115x140x16 ) cr make , adaptor for oil supply , joint for adaptor ( turbo side ) , assly of lub oil inlet pipe for k24 tc , adaptor ( crankcase side ) , joint for adaptor ( crankcase side ) , joint for lub oil drain pipe , hose ( for turbo dtain pipe 170 mm ) , joint for adaptor crankcase side , head machined for bolt 50.003.08.020 h , set screw m8x1.25x35 8.8 , set bolt m8x1.25x45 8.8 , l.o. drain pipe assly. , adaptor assly for turbo drain , piston assembly complete , piston pin , circlip ( internal ) 35 mm , piston ring set ( 105 dia. ) , con rod assembly ( without le bearing ) , connecting rod bolt , poly v belt , push rod ( welded ) , valve tappet , rocker cover assembly ge top lub oil fil , p k drive screw 1 / 8x3 / 8 ( rivet ) , set bolt m8x1.25x100 8.8 , joint for rocker cover , sealing washer ( for oil filling cap ) , oil filler cap , rocker support assembly complete ( e type , washer ( for rocker arm ) , v.r.toe , rocker arm adj. screw , nut for rocker adj.screw , oil metering orifice , starter ( 24v ) , spacer for 24v starter , assembly suction tube for 35 deg inclina , thermostat & housing , thermostat element ( 74 deg ) wtil no.de , joint for thermostat cover , copper washer ( 14x18 ) , thermostat bypass hose , stepless ear clamp for dia 44 , joint for thermostat housing , turbocharger tel ) k26 2664 gga 8.11 ( tel , gasket ( for turbocharger ) , water pump assly 282.5 crs, w / o pulley , joint for delivery volute , set bolt m10x1.5x60 8.8 , plastic cap for water pump inlet , water pump pulley poly v groove 138 pcd , water separator ( 9 450 030 205 ) , mud collector filter ( 9 450 030 200 ) , fuel filter element pre , spring washer m12 , set of `o rings , main bearing ha std. , main bearing ha , main bearing ha , main bearing ha , main bearing ha , conrod bearing ha std. , conrod bearing ha , conrod bearing ha , conrod bearing ha , conrod bearing ha , set screwm10x1.5x258.8 , adaptor m12x1.5 ( male ) & m10x1.5 ( female , set screw m8x1.25x16 8.8 , precoated plug , crankshaft ( assembly ) integral 38mnvs6 , spring dowel , crankshaft pulley poly v to suit fpto , exhaust manifold , set bolt m8x1.25x75 8.8 , fuel filter element micro , set screw m12x1.75x35 8.8 , fuel injection pump for 4r1040t engine , gear casing ( finish ) , joint for gear casing , cover for cam shaft bore on gear casi , set screw m6x1x12 8.8 , timing pointer , set bolt m8x1.25x85 8.8 , mud slinger , inlet manifold ( top opening ) , set bolt m8x1.25x65 8.8 , set screw m8x1.25x35 8.8 , air pipe turbo to inlet manifold , hose t bolt clamp ( dia. 55 65 ) , set bolt m8x1.25x120 8.8 , support for intermediate gear , joint , worm drive hose clip ( 41 mm ) , copper washer ( 8x14 ) , set screw m8x1.25x30 8.8 , set screw m6x1x16 8.8 , set bolt m8x1.25x70 8.8 , plug with magnet & oring. , lube oil pressure sendor , rubber sleeve 38x10 for pr gauge send , bracket for stop lever mounting , alternator pulley with poly v groove , adaptor ( turbocharger ) , lub oil inlet pipe , joint for adaptor , set screw m8x1.25x20 8.8 , l.o. drain pipe , poly v belt , rocker cover joint mettalic , stud m10x1.5x60 8.8 , thermostat and housing , joint for thermostat cover ( mettalic ) , turbocharger k16 2371n 5.82 for 4r104 , joint ( for turbocharger ) , water pump pulley poly v groove ( p6pk , set bolt m12x1.75x45 8.8 , filter, fuel ( ds ) , strainner, fuel , clamp , hose , alternator , connection, air intake , hose, elbow , tube, air , hose elbow , clamp hose , screw, twelve point cap , crankshaft, engine , seal, o ring , plug pipe , nozzle, piston cooling , plug, pipe , bushing , plug, expansion , bearing, crankshaft thrust , sleeve, salvage , screw hexagon head cap , camshaft , gear, camshaft , support camshaft thrust , screw, hexagon head cap , key, plain woodruf , cleaner, air , element, air cleaner , element, inner , clamp, v band , seal, rectangular ring , core, cooler , gasket, oil cooler , gasket, filter , head, lub oil , valve, pressure relief , plunger, prs regualr , spring, compression , screw, hex flange head cap , plug, threaded , tee, female branch , brace, fuel pump , stud , brace, fuel pump , screw, hex flange head cap , nut, hexagon flange , cap, tube , spacer, mounting , hose, flexible , washer, sealing , nipple, plain hexagon , gear, fuel pump , gasket, push rod cover , cover, push rod , seal, grommet , screw, hex flange head cap , hose, plain , clamp, spring hose , gasket, gear housing alter part no. 3938 , housing, gear , cover, gear , screw, hex flange head cap , seal, rectangular ring , housing, timing pin , seal, o ring , pin, timing , ring, retaining , screw, round head cap , screw, hex flange , screw, hexagon head cap , seal, oil , gasket, valve cover , valve, cover , cover, valve , isolator, noise , screw, hex flange , seal, rectangular , cap, filler , screw, hex flange head , damper, vibration , screw, hex flange head cap , bracket, belt tension , screw, hex flange head cap , screw, flat head cap , belt, v ribbed , tensioner, belt , belt, v ribbed ( 1389mm ) , pulley, fan , screw, hex flange head cap , support, fan , gasket, acc drive cover , gasket, rectangular , head, fuel filter , adaptor, filter head , seal, o ring , nut, regular hexagonal , head, fuel filter , seal, rectangualr ring , adaptor, filter head , catridge, lub oil filter , filter, fuel , separator, fuelwater , element engine oilfilter , separator, fuel water ( ds ) , element main fuelfilter , tappet, valve , tube, oil gauge , dipstick , seal, o ring , plug, expansion , clip , dipstick , fg cylinder head , plug, expansion , seal, valve stem , valve, intake , valve, exhaust , spring, valve , spring, valve , retainer, valve spring , collet, valve , screw, hex flange head cap , screw, hex flange head cap , plug, pipe , housing, flywheel , screw, hex flange head cap , plate, cover , cover, rear , seal, oil , gasket, rear cover , plug, threaded , plug, o ring , screw, hex flange head cap , injector , seal, rectangular , rod, push , screw, hexagon head cap , screw, hex flange , shaft, rocker lever , lever, rocker , screw, rkr lever adjusting , nut, heavy hexagon , lever, rocker , washer, plain , ring, retaining , pin, throttle lever pivot , banjo connector , washer, sealing , cover, intake , gasket, int manifold cover , screw, hex flange head cap , manifold, exhaust , motor, starting , support, alternator , screw, hex flange head cap , brace, alternator , screw, hex flange head cap , screw, hex flange head cap , clamp, tube , gasket, cylinder head , brace, tube , clip , solenoid, fuel pump , bracket, governor , bracket, solenoid , screw, hex flange head cap , gasket, cover plate , harness, wiring , washer sealing , screw, hexagon head cap , washer sealing , washer, plain , nut, lock , lever, shutoff valve , screw, hexagon head cap , nut, lock , timer, overcrank , screw, hex flange head cap , gasket, exhaust manifold , screw, hex flange head cap , flywheel , gear, flywheel ring , screw, captive washer cap , screw, hex flange head cap , screw, hex flange , pan, oil , gasket, flange , plug threaded , plug threaded , washer, sealing , washer, sealing , connection, oil suction , pan, oil , connection, oil suction , plate, cylinder block , screw, connecting rod , bushing , kit, piston 6bt , kit, conn rod bearing , ring, retaining , set, piston ring , rod, engine connecting , pin, piston , valve, check , seal, banjo connector , screw, captive washer cap , manifold, fuel , tube, injector fuel supply , tube, injector fuel supply , tube, fuel supply , washer, sealing , screw, banjo connector , screw, banjo connector , connection, tur oil drain , gasket , clamp, hose , hose, plain , tube, turbo oil drail , hose, flexible , connector, female , washer, sealing , seal, o ring , pulley, crankshaft , pump, fuel injection , pump, fuel transfer , tube, fuel supply , screw, banjo connector , spacer, mounting , pump, lubricating oil , screw, hexagon head cap , pump, water , seal, o ring , seal, rectangular ring , screw, hex flange head cap , spacer, fan , spacer, fanpilot , thermostat , turbocharger , turbocharger , gasket, turbocharger , stud, double end , nut, hexagon flange , connector, male , set, lower engine gasket , set, upper engine gasket , front seal service kit , long block , kit, water pump , kit, engine piston , repair kit, turbocharger , kit, main bearing , kit, turbocharger repair , cylinder head overhaul kit 6bt std bsii , set, lower engine gasket , set, upper engine gasket , long block ( deep sump lbs b5.9 , connection, spacer , gasket, connection , connection, air intake , pipe, air transfer , plug, pipe , clamp, v band , gasket, thm housing cover , housing, thermostat , bracket, lifting , screw, hex flange head cap , forklift fork 4a ( 150*60*1220 ) , fork ( 3a 125x45x1200 ) , fork ( 3a 125x45x1500 ) , fork ( 2a 100x40x1200 ) , fork extension ( 140x65x2000 ) , charger smps based ( 24v, 30a ) , charger ( 48v / 95a ) , charger ( 48v, 35a ) , rotary attachment execution 2.5t351.1g , fork extension ( fe 120*65*1800 ) , side shifter assy 2ton , side shifter assy 3ton , side shifter assy 5ton , fork extension ( fe 210*95*2300 ) , charger ( 36v / 150ah ) , bale clamp attachment 3t , foam clamp attachment 3t , double drum attachment ( parrot beak 3t ) , single double pallet handler for class , muffler assy , muffler assy , radiator assy 13t , hyd. oil cooler assy 13t , engine assy odi r210 , hose air intake , muffler assy , bracket support muffler , roc assembly , wire net rad assy , bracket rad , hose cooling , hose cooling , radiator r215l , oil cooler r215l , fan cowl r215l , fan guard r215l , frame assy r215l , radiator assy r210 , oil cooler assy r210 , fan cowl r210 , fan guard r210 , rad frame assy r210 , hose cac , hose upper , hose lower , hose cac upper , hose cac lower , rad. drain plug r215l , pressure cap r215l , hose pipe with clip assy r215l , rad. drain plug r210 , oil cooler drain plug r210 , hose pipe with clip assy r210 , pre filter assy mounting bracket , hygen premium engine oil 5l , hygen premium engine oil 20l , hygen premium engine oil 210l , engine assy , hose airintake , exhaustpipewa , elbow 90 , outer sliding , yoke sleeve , yoke sleeve , spacer , screw round head , flange complete , flange complete , flange complete , bearing set main, std , bearing set main , bearing set main ( us0.25 ) , main bearing set us0.50 , bearing set main ( us1.00 ) , crankcase assy , bolt , liner cylinder , liner cyl a , packing rubber , packing rubber , valve check , body oil jet , bushing , bushing , bushing camshaft , bushing , bushing , o ring , plug , gasket , plug , washer lock , plate rhrust , plate thrust , plate thrust o.s 0.15 , plate rear , gasket rear plate , gasket , gasket oil pan , pan assy oil , hose water drain , cover front , gasket , gasket , gasket , gasket side cover , oil seal , oil seal front , plate seal , cock drain , cover , cover , gasket , gasket , gasket , cover side , cover side b , gasket , fnr controller ( elec, 24 / 36 / 48v ) , battery assy vce / 600a 25b 9f , battery assy 48v 600ah , battery 48v 600ah 25b 9f , battery assy 48v, 660ah ( 30b 9f ) , battery assy 48v / 660ah , battery assy 48v / 660ah 30b 9f , battery assy 48v / 660ah 30b 9f , battery assy 48v 720ah ( 30b 9f ) , battery assy 48v / 465ah ( 16brj 9 ) , battery assy 80v 700ah , battery assy 24v 300ah , battery assy 24v 280 / 300ah , attery assy 80v 700ah , battery tray for 80v700ah , battery assy 24v 300ah , battery assy 36v / 864ah , batteryassy 48v / 630ah ( 30b 9f ) , battery assy 48v / 560ah ( 16brj 9 ) , battery assy 48v 720ah , fuse 10a ( tac, 58v, blade ) , beacon lamp led , beacon light , motor traction , switch combi ( dir ) , switch combi , controller ac3 , controller dual ac2 , controller dualac2 , controller ac2 , helice ventilador empilha , fan san ace120 , fan , switch combi , switch combi bk lr , accelerator assy , accelerator assy , battery assy 80v 700ah ( 50b 9 ) , battery assy 80v 700ah ( 50b 9 ) , switch assy, 2sp ctl vlv , switch assy 3 spool , switch assly 4 spool , main fuse , harness main , display , bulb kit, crawler , resistor , fuse , fuse 30a , fuse 20a , fuse 10a , bulb room lamp , cable ( batt ry starter ) , cable ( batt ry starter ) , cable ( batt batt ry ) , cable ( batt batt ) , cable ( batt batt ) , relay ( nsp ) , relay light ( 4p ) , switch pressure , relay power , sensor temp , speed sensor , pressure sensor , switch over heat ( water temp ) , switch temp , lighter cigar , relay 4 pronge , buzzer travel alarm , buzzer warning , relay ( =e125 0004 ) , fuel sendor , relay battery , cable ( b / ry starter ) , ignition switch starter , cover , nsert rotary , battery , switch lamp , switch , switch washer , switch, beacon , switch , switch parking , switch breaker , sw c / cut off , switch over load , plate , prolix resister , clip harness , plate , cable ( batt earth ) , switch light , switch prolix , sw quick coupling , potention meter , prolix resistor ( resistor ) , tachometer ( cum.118pulse ) , harness ext, start ry , harness ext, start ry , cable ( earth master sw ) , cable ( master sw earth ) , link fusible , fitting temp sw , packing temp sw , valve check , diode , diode , horn low , cable ( batt ry starter ) , temp sensor , cable starter , gauge water temp , gauge fuel , adapter temp sender , cable ( batt earth m / sw ) , cable ( batt ry starter ) , motor pump assy , tank , motor wiper , washer tank assy , sensor, pump pressure 500bar , sensor, pilot pressure 50 bar , lamp room , strap earth , lamp , lamp beacon , lamp tail stop flasher , lamp , bulb, worklamp , bulb head lamp , bulb , bulb ( 5w ) , bulb , bulb , lamp flasher position , lamp head , front turn lamp , lamp assy , rear combi lamp , beacon sub assy 24v , seal , cable ( master sw earth ) , sender temp , harness rear combi , harness ext , harness ext , harness n / plate lamp , pump washer motor , hose , connector tube , hose rubber , clamp quick , o ring , rotor , vane , seal oil , box switch , check valve assy , washer , fitting , nut elbow , elbow , strainer assy , hose inlet , service kit , service kit , cap assy , hose assy , adapter temp sender , adapter oil pressure , cable ( batt batt ) , cable batt & master sw , washer plain , accel actuator , accel actuator , actuator accel , accel actuator , accel actuator , accel actuator ( 2000l ) , accel actuator , accel actuator , accel actuator , accel actuator , accel actuator ( 2300l ) , accel actuator ( 2300l ) , accel actuator , sender temp , flasher unit assy , flasher unit assy , frame switch mount , relay start , back buzzer , back buzzer , fuel sender , connector battery , battery connector with handle for forkli , motor assy pump , switch micro , fuse ( 300a ) , fuse ( 350a ) , switch parking , card can / tiller , controller fingertip , accelerator assy , accelerator assy , cap one touch, battery , cap one touch, v type , sensor temp , converter assy , combi lamp assy , turn signal lamp assy , turn signal lamp , resistor , connector , connector with handle reach truck , converter dc , transformer aux , pump motor assy , switch assy starter , switch starter , key start , temp sensor , battery 48v 280ah , battery assy wet / 48v / 280a 15br 9 , battery assy 48v 280ah with afs kit , battery assy 48v 300ah ( 20br 9 ) , battery assy 48v 300ah ( 20br 9 ) , switch foot , harness switch , filter assy eps , sensor torque , torque sensor , actuator eps , eps motor , switch horn , switch assy , module scr , eps controller assy , harness frame , harness transmission , strap earth , switch auto , key assy start , switch wiper , key assy start , start key assy , switch , flasher unit , battery trolley ( model 18br 9 ) , fuse box , fan assy duct , cooling fan , fan , fan assy duct , bracket , harness ext , harness ring terminal , invert , pedal assy accel , fuse 30a ( tac, 58v, blade ) , fusebox assy , motor eps , eps filter assy , switch assy 3 spool , switch assy 3spool , switch assy 4spool , actuator assy eps , eps motor , accelerator assy , accelerator assy , controller traction , ace2 48v / 450a ( pump ) , camera assy rear view , switch assy limit , switch parking , gear seletor , mcu , cluster , pedal accelerator , gear selector , gear selector , lanterna empil , lamp work , switch fuel warmer , switch beacon lamp , relay micro, 24v / 5p , charger assy batt ( 3p 440v ) , cell batt / vci440 , switch assy, 2sp ctl vlv , strap static , contactor , switch assy key , resistor contactor , battery assy 48v 585a , battery assy 48v / 585a 20b 9 , battery assy 48v 550ah ( 20b 9f ) , battery 48v 585ah 20b 9f , battery assy 48v 575ah ( 16b 9f ) , battery assy 48v 600ah ( 16b 9f ) , exide battery assy 48v / 425ah ( 20b 9 ) , battery assy 48v / 510a ( 15bt 9u ) , drive motor assy , pump motor assy , controller traction , cluster , panel cluster, stee column , buzzer back , bulb , bracket , lamp beacon , combi lamp , lamp license , bulb , bracket , contactor , fuse , fuse 10a , fuse ( 15a ) , fuse ( 30a ) , fuse ( 2a ) , battery assy 48v 230ah , battery assy 48v 280ah ( 40t 9 ) , motor assy tracion , fusebox assy , fusebox assy , switch mode , switch head lamp , switch inching , switch inching bwd , can mdi , inverter ace2 , charger assy batt ( 3p 410v ) , charger ( mp3 80v / 90a ) , fan cooling , inverter ac3 , ac over load , console digital , adapter pc , potentiometer , potentiometer , cooling fan , display , batteryassy 48v / 440ah , battery48v440ah ( 20b 9f ) , battery 48v440ah ( 20b 9f ) , battery 48v440ah 16b 9f , switch assy sbr , contactor , contactor sw80b ( 36 / 48v ) , contactor , relay sw80bee 36v 48v , motor traction , motor pump , main harness ( zapi non ul ) , harness main , dual controller , ac2 controller , controller dual , controller ace2 , body fusebox , harness ext travelcut relay , motor eps , motor eps , motor stepping & gear , camera fork mounted , fork mounted wireless camera , strap static , switch reach in , switch reach out , camera display ( monitor ) , lever fingertip , switch assy limit , switch direction , switch horn , harness valve , control eps , position sensor , battery 48v620ah for 16brj 9 , batteryassy 48v, 465ah ( 16brj 9 ) , battery assy 48v 620ah ( 16brj 9 ) , battery assy 48v 500ah ( 16brj 9 ) , battery assy 48v 600ah ( 16brj 9 ) , batteryassy wet / 48v / 700a25brj 9 , batteryassy wet / 48v / 775a25brj 9 , battery assy 48v 620ah ( 20brj 9 ) , batteryassy 48v, 500ah ( 16brj 9 ) , battery assy 48v 700ah ( 25brj 9 ) , battery assy 48v 775ah ( 25brj 9 ) , bracket monitor , bracket camera , switch assy batt remove , terminal bolt , switch assy lift end , harness main nonul , cable camera , inverter ac2 , pedal assy brake , horn ( high ) , harness dashboard , gear selector , combination switch , switch combination , led blue spot , blue spot light , blue spot , switch combination , combination switch , carriage mounted wireless camera , g sensor assly , puller ( mini ) fuse , mini fuse ( ul ) 5a , mini fuse ( ul ) 10a , mini fuse ( ul ) 15a , slow blow fuse 60a , back light switch , switch hazard , switch beacon , cable batt , battery assy 36v / 800ah , hanger , connector , brake assy electric , joystick valve assy , inverter ac2 , inverter ac2 , motor traction , motor pump , pressure sensor , angle sensor , strap static , controller , fuse box , switch tilt , switch assy key , switch assy key , switch assy key , switch assy emergency , contactor , contactor , display , display , battery assy 48v 625ah ( 13bop 9 ) , battery trolley for b0p ( 13bop ) , switch emergency , switch fan , bracket wa , bracket pulley , hanger , fan 4312m , controller ace2 , controller ace0 , fuse 125a , harness side rh , harness rh console , cluster assy , harness front camera , cable battery to battery , cable batt ry starter , hose rubber , antenna , rmcu , rmcu , harness cigar , rdu relay drive unit , antenna fm / am , motor assy , controller wiper motor , arm assy wiper , blade assy wiper , valve assy , player radio&usb b / t , motor kit wiper assy , playerassy radio&usb , player assy radio usb , camera assy rear view , aircompressor , harness boom wire , harness engine , harness engine , harness frame , cable batt + relay , service meter ( =j907141600 ) , battery , battery pt200 , adapter , switch, clutch pressure ( 25bar ) , harness cab , harness front , harness transmission , harness extension ( hl780 3a ) , control unit ( est 37t ) , adapter , main harness ( hl780 3a ) , harness engine , harness frame ( hl780 3a ) , accelerator pedal , check unit , proximity switch , switch board assy ( hl780 3a ) , wiper arm rear , wiper blade rear , switch aircon , switch wiper / washer , switch light , switch master , switch master , sw air cleaner , cable ( batt switch ) , cable ( batt batt ry ) , cable ( heater ry batt ry ) , switch work lamp , strap earth , gear selector , display , cable ( batt sw&earth ) , harness cab , fuel sender , harness main , harness main , harness engine , harness frame ( hl770 7 ) , harness frame , harness front ( hl770 7 ) , harness cab, front , head lamp ( abl ) , plate switch board , cable ( starter heat ry ) , harness eng , harness frame , harness front , harness cab , mcu , mcu ( machine control unit ) , earth strap , cable ( batt batt ry ) , controller , switch hazard , switch parking , switch main light , switch work lamp , switch auto select , switch clutch cut off , sw rr wiper / washer , switch buzzer stop , switch beacon , cover assy fuse box , cluster assy , cluster assy ( 730~770 7 ) , cluster assy , harness main , harness engine , harness frame , harness front , harness front , harness ext ( start ry ) , decal master sw , fuel sender , harness main , harness frame , resister , plate , beacon lamp magnetic assy , flasher unit , work lamp cabin , cigar lighter , switch master , switch master , switch master , switch master , front wiper arm&blade assy , wiper motor assy , switch assy , check v / v assy , switch beacon , flasher unit assy , controller shift , battery relay , sender assy fuel , high horn assy ( 12v ) , horn high , relay kit assy , bracket light , bracket light , switch w / lamp ( 12v ) , fuel sender , resister , fuel filler pump kit , fuel filler pump kit , fuelfillerpumpassy , wiper motor assy , wiper arm assy , motor wiper , arm wiper , wiper blade rear , blade wiper , cluster assy , circuit breaker ( 60a ) , lamp work , antenna fm / am , harness cabin , harness airconditioner , sensor fuel level , switch travel 1 / 2 speed , harness lh stand , harness relay board , gauge panel assy , hour meter assy , meter hour , harness boom , switch assy starter , switch start hd62 , key start , harness fusebox , harness fusebox , relay , harness ext cabin work lamp , cluster assy , cluster assy , cluster assy , cluster assy , harness main , harness frame , harness frame , harness engine , harness boom , relay board assy , relay board assy , fuse box assy , membrane switch assy , membrane switch assy , bracket battery , bracket battery , bracket battery , plate , cable ( batt+ batt ry ) , cable ( batt batt ) , plate bending , cover fuse , harness frame , harness frame , harness frame , harness frame , harness boom , washer tank assy , hose outlet , harness frame , frame harness , mcu ( machine control unit ) , mcu , m.c.u ( machine control unit ) ( r80 7 ( i ) ) , m.c.u ( machine control unit ) , mcu , mcu , mcu , wiper motor kit assy , harness eng , bracket w.a. , start sw assy incl key , harness frame , harness boom , cover assy fuse box , harness engine , cable ( heater heater ry ) , decal relay , bracket battery , cover battery , cable ( batt batt ) , harness rh, console , harnes frame , harness frame , harness frame , frame harness , harness boom , cluster assy , dacal switch , mcu , mcu ( i ) ( r110 7 ) , mcu ( r110 7 ( i ) ) , mcu ( machine control unit ) , mcu , mcu , harness engine , decal fuse box , timer relay , clip , clip econo seal , plate clip , plate clip , switch outrigger ( r140w 7 ) , switch travel , fusible link , link fusible ( 30a ) , fusible link , harness ext, travel , harness rh, console , antenna assy , harness boom , key assy start , key start , switch assy incl key , switch start , key start , switch master , key master switch , switch master , decal master sw , hour meter assy , ext harness hour meter , harness frame , harness frame , harness eng, front , harness engine front , harness eng, rear , harness eng, rear , outlet hose , outlet hose , hose outlet , ext harness usb , cpu controller , mcu , mcu , harness extension , switch seat heat , mcu , buzzer travel alarm , relay 5p , harness ext ( lamp ) , fuse & bulb kit , harness frame , harness eng.front , harness eng.rear , horn low , horn low , horn high , horn high , harness boom , cpu controller , mcu ( machine cntl unit ) , decal master sw , harness cab , harness cab , remi fans 8 12v / 24v blue , arm wiper , blade wiper , motor wiper see notes before order , bracket wa , nozzle , grommet , switch fan , wiper motor kit assy , arm wiper , arm wiper , blade wiper , wiper motor assy , bracket parking , bracket & link assy , bracket kit & link , controller w / motor , controller wiper motor , controller w / motor , motor wiper , motor wiper , motor cam , cam base w / motor , cable ( alt starter ) , cable ( alt starter ) , lamp room 24v , boom wire harness , cover batt relay , bracket relay , bracket relay , speaker , antenna , plate , seal , plate , plate c / radio cover , sender fuel , sender fuel , float , harness engine front , harness engine rear , harness frame , cable ( alt starter ) , plate clamp , cable ( alt starter ) , plate front cover , rubber pad , work lamp assy , work lamp assy , bracket light , work lamp assy , pump & motor assy , pump & motor assy , pump & motor assy , fuel filler pump assy , pump total assy fuel filler , buzzer travel alarm , circuit breaker , switch toggle , switch assy membrane , switch assy membrane , plate horn , harness frame , harness frame , harness frame , harness engine front , harness engine front , harness engine rear , wire link ( register ) , bracket batt , cable ( heat ry a / heater ) , wiringharness , fuel filler pump , cluster assy , cluster assy , cluster assy , relay start , cable rs232 ( cpu pc ) , hrdt 2.0 tool kit , cable rs232 & usb , controller cpu , m.c.u ( machine control unit ) , m.c.u ( machine control unit ) , m.c.u ( machine control unit ) , mcu , mcu , m.c.u ( machine control unit ) , mcu ( machine control unit ) , mcu ( machine control unit ) , m.c.u ( machine control unit ) , mcu , m.c.u , m.c.u ( machine control unit ) , mcu ( 20t smart ) , mcu , mcu ( machinecontrolunit ) , mcu ( machine control unit ) , mcu , cpu , harness side, rh , cover battery , harness frame , harness frame , harness frame , engine front , harness eng.rear , boom wire harness , harness console, lh , harness console, rh , harness side, rh , cabin fan harness , harness frame , harness frame , cover assy ( fuse box ) , cover fuse box , harness frame , harness frame , harness frame , switch assy membrane , switch assy membrane , harness eng.rear , harness engine front , accel actuator mounting plate ( 21en 323 , harness frame , harness frame , harness frame , radio / usb player , digital hour meter assy , start ext. ry. harness , power socket , hour meter pigtail , engine front harness , engine rear harness , console harness rh , harness side, rh , cabin harness , boom harness , cabin fan harness , cable ( alt starter ) , lh console harness , work lamp assy. ( amp connector hella ) , relay 5p, 24v , lamp pigtail tool box , by pass connector , extn lh console w / h , extn. rh wire w / h , extn. rh side w / h , extn cabin w / h , extn ac harness , harnes buzzersw , harnessextn , travelbuzzerswitch , switch quick coupler , main light switch , cabin lamp switch , switch aircon , rock breaker switch , fan switch = l24b1b0j1 azh00 1mf , wiper & washer switch l73b1b0j1 azh00 16 , music player switch l24b1b0j1 azh00 12g , resistor , diode , adapter oil pressure , cpu , bracket beacon , cable ry&starter , electric box assy , harness ext wire , harness frame , harness boom , harness rh , rh harness wire , harness lh, console , harness pump , harness side rh , harness wiper , harness wiper , harness wiper , cable ( master sw batt ) , cable ( batt ( + ) relay ) , cable ( alt starter ) , cable ( batt relay ) , harness frame , harness frame , harness engine , cable ( alt earth ) , harness console rh , harness lh, console , harness console ( lh ) , harness pump ps , harness side rh , decal emer control , harness frame , harness frame , harness eng fr , harness eng fr , harness eng rr , harness eng rr , cable starter&h / ry , box kit electric , elect box kit , elec. box kit assy , socket 12v , body fuse box ( 7 ) , cover fuse box , knob assy fuse box ( 7 / 9 ) , rubber pad fuse box ( 7 / 9 ) , nut insert , seal fuse box ( 7 ) , insert , o ring fuse box ( 7 / 9 ) , cover fuse box , cover fuse box ( 7 ) , dc dc converter assy , switch assy safety ( 7 / a, 9 ex ) , membrane switch assy , membrane switch assy , membrane switch assy , bracket relay , accel dial assy , accel dial assy , dial assy accel , potentio meter , knob , bracket wa , cover wiper motor , sw remote control , bracket wa , plate , plate connector , cable ( heat ry a / heater ) , bracket batt.relay , cassette radio usa , cassette radio general , cluster assy , cluster , cluster , cluster assy , case upper , case lower , decal switch , decal display , light unit back , light unit back , board main , rom cluster , lcd unit , board assy &module , switch board assy , mcu ( machine control unit ) , cpu controller assy , cpu controller , mcu ( machine control unit ) , machine control unit , mcu ( machine control unit ) , cluster assy , cluster assy , cluster assy , cluster assy ( 7series excavator ) , switch assy , decal switch , cluster assy ( 140~800 7 / a ) , switch assy , decal relay , harness ext, relay , frame harness , harness frame , front engine harness , rear engine harness , harness , switch econo , harness master sw , ext.harness a / ride seat , cd player assy ( 110~800 7 / a ) , sw remote control , cable ( battry starter ) , relay heater , cassette radio assy , cassette radio assy , harness ext, wire , cable , radio / usb player assy , radio / usb player , harness frame , harness frame , harness frame , harness engine , harness engine , harness engine , harness boom wire , cable heater , harness engine, rr , cpu controller , m.c.u , mcu ( machine control unit ) , mcu ( machine control unit ) , mcu , harness frame , harness frame , bracket battery ry , cable ( ht ry air heat ) , cable ( master sw earth ) , strap earth , harness pump ps , cover fuse box , harness frame , harness engine, fr , harness engine, rr , harness pump , mcu ( m / conrol unit ) , harness ext, start ry , harness ext , harness frame , harness frame , harness frame , harness frame , harness engine , harness engine , harness eng , harness engine , bracket battery , fuel sender , sender fuel , decal relay , cover battery , harness boom , cpu controller , mcu ( machine cntl unit ) cpu , mcu ( machine cntl unit ) , mcu ( machine control unit ) , m.c.u ( machine control unit ) , switch assy membrane , harness pump ps , harness , cable ( pre heater earth ) , pigtail air cleaner , harness engine , cable ( batt batt ) , cable ( batt batt ry ) , cable ( batt ry starter ) , cable ( batt earth ) , cable ( batt earth ) , wire link alternator , harness pump ps , harness ext, start ry , harness pump ps , harness boom , mcu ( machine control unit ) , start key assy , key assy start , circuit breaker ( 30a ) , key start , fuel sender , resistor assy , harness side, rh , harness rh, console , harness side, rh , harness side rh , fusible link , resistor assy , beacon lamp , dial accel , accel dial assy , key assy , switch beacon , beacon lamp assy , beacon lamp assy , guard lamp , mcu ( machine control unit ) , mcu ( machine control unit ) , mcu ( machine control unit ) , m.c.u ( machine control unit ) , m.c.u ( machine control unit ) , mcu , m.c.u ( machine control unit ) , m.c.u ( machine control unit ) , mcu , lamp room , battery cover , cable batt & batt , work lamp assy , harness boom , harness frame , harness frame , harness frame , harness frame , harness engine , harness eng ( r140lc 9 ) , fuse & bulb kit , cover , pressure sensor , harness fuel saving , harness side, rh , harness lh, console , harness rh, console , harness frame , harness engine , harness boom , cabin fan harness , harness ext ( start ry ) , cabin harness , harness wiper , lamp pigtail r140 9 , cluster assy , cluster , arm wiper , blade wiper , harness console ( lh ) , harness rh, console , harness cab , cover relay , cover relay , harness camera , harness side / rh , harness antenna , speed sensor , plate mcu , harness eng , harness frame , relay fuse box , sender fuel , cable rmcu , cluster assy , switchassy membrane , pump total assy fuel filler , mcu ( machine control unit ) , cluster assy , fuel filler pump , pump f / filler , alternator assy , alternator assy , alternator , alternator assy , alternator assy , rear view camera kit assy , camera assy rear view , harness frame , body, fuse box , cover, fuse box , harness breaker , harness ext , harness overload , harness camera , harness ext lamp , mobile antenna , harness dashboard , harness eng , harness pump , mcu , harness frame , m.c.u ( machine control unit ) , mcu ( machine control unit ) , rmcu , relay battery , batt relay , plate , sender fuel , harness boom , harness engine , work lamp bracket , harness ext ( master sw ) , mcu machine control unit , hce dt kit , work lamp assy , switch air con ( 2 position ) , lamp room , relay start , relay power , relay power , relay power , switch main light , clamp plastic , lamp work / led , ext.harness tvs diode , ext.harness_tvsdiode , ext.harness tvs diode , fuel sensor , switch multifunction , harness aircon & heater , head lamp lh , head lamp rh , harness front , air pressure sensor , oil pressure sensor , oil temp sensor , oil pressure sensor , actuator , gauge water temp , gauge air ( sl ) , gauge t / m temp ( sl ) , gauge tm oil pr ( sl ) , gauge fuel level ( sl ) , sensor temp , pressure sensor , pressure sensor , water temp meter , hour meter assy , brake air pressure meter , oil temp meter , oil pressure meter , fuel meter , washer tank assy , fuel sendor , switch engine stop , yoke sleeve , flange drive line , cyl head assy, eng , insert valve , inlet valve , guide , guide valve / inlet , guide valve ( exhaust ) , guide valve / exh , stud , o ring , valve director , stud , tube nozzle , pipe nozzle , plug , o ring ( an ?? ) , inlet valve , valve inlet , valve exhaust , exhaust valve , spring , retainer upper , cotter valve, vlv gear train , seal valve stem , retainer lower , cap , spring , gasket cyl head , bolt cyl head , bolt cyl.head , cover rocker , washer , gasket rocker cover , seal oil , bolt , cable , nut castle , relay , relay , spacer , seal , ring set piston , bearing set, con rod ( 6pcs ) , bearing set c / r, std , bearing set conrod / us:0.25 , bearing set main / us , bearing set conrod / us:0.75 , bearing set conrod / us:1.00 , crank shaft assy , pulley crank shaft , gear crank shaft , pin dowel , slinger front , flywheel assy , flywheel assy , gear ring , gear ring , bolt flywheel , piston, std , pin piston , gasket round , ring snap , connecting rod assy , connecting rod assy , bolt connecting rod , nut , bushing , cable mast1 , cable mast2 , cable mast3 , shaft cam , plate thrust , push rod , push rod, vlv gear train , tappet valve , o ring 1a p 7.0 , o ring 1a p 32 0 , o ring 1a s 24.0 , rocker shaft assy , rocker assy , shaft rocker , rocker assy , bracket , screw adjusting , plate sensor , gear assy idler , bushing ilder , plug oil spray , shaft idler , pin dowel , plate thrust , plate thrust , bolt idler shaft , o ring , collar , gear assy idler , sender fuel , fuse box , relay , cable ( terminal batt ) , sw multifunction , cable ( batt earth ) , tank , cap , rubber bush , plate , blade wiper ( front ) , wiper motor assy , wiper arm assy , wiper arm assy , wiper blade , valve wiper , cable ( terminal relay ) , control unit ( est 37a ) transmission , pump ass y water , v belt , belt fan , bearing ball , bearing ball , o ring , belt fan , belt fan , belt fan ( r300lc 7 ) , water pump v belt , v belt ( 43inch, 1105mm ) , pulley fan ( d6az c4 ) , pulley fan , washer , coupling fan , hose assy , damper torsional , fan drive , drive assy fan , gasket , gasket thermostat , case thermostat , cover thermostat , hose rubber , hose ( by pass ) , pipe a water outlet , case assy thermostat , thermostat assy , thermostat assy , pulley assy tension , bearing ( 6204d ) fan & pulley , pulley idler, w / pump & fan , battery , sender temp , gauge t / mtemp , voltmeter , sender trans temp , clip assy , clip assy , clip assy ( 3 ) , alarm , pump assy, oil , strainer oil , gasket , gasket , gasket , gasket , gasket , filter engine oil , filter assy eng oil , filter assy engine oil , head oil fitler , filter , eng oil filter assy , oil cooler assy , o ring , o ring , alarm bypass oil , element oil cooler ( nsp ) , valve assy by pass , gasket , o ring , o ring , o ring , o ring , cap oil filter , oil filler , gasket , dipstick assy , guide oil level gauge , breather , breather , o ring , pipe oil return , pipe , pipe return , pipe oil inlet , clamp , regulating valve assy , gasket , pipe , pipe oil a , pipe return , bolt eye , hose , seal , seal , harness dashboard , pedal assy elec accel , turbocharger assy , turbocharger , gasket , gasket , bolt , manifold inlet front , manifold inlet rr , gasket , pipe inlet , bolt , insulator , ring expansion , ring seal, exh.manifold , seal ring , gasket , strap earth , hosing fly wheel , seal oil , retainer , pointer rear , o ring , slinger oil seal , cover pointer , gasket , strainer assy , charger ( 48v, 75a ) , charger ( 48v, 85a ) , charger ( 48v, 65a ) , charger ( 24v, 100a ) , charger ( 48v, 55a ) , charger ( 80v, 80ah ) , w / h rh side , antennabracket , rubber bellow , harness extension , engine rear harness , harness side, rh , harness side, rh , harness frame , harness side, rh , rmcu , rmcu mounting bracket ( local ) , start key assy , harness frame , shaft yoke , shaft yoke , seal kit ( boom r110 lt ) , retainer upper , plug sub kit , handle for sr350 connector , head cylinder , cap , gasket , pipe injection 1 , pipe injection 2 , clamp , pipe injection 3 , pipe injection 4 , pipe injection 5 , pipe injection 6 , hose fuel feed , pipe suction , hose fuel feed , pipe , pipe , pipe over flow , thermostat , fuel filter assy , gasket , bolt eye , cock air vent , head fuel filter , element , fuel filter assy , element fuel filter , element filter , eng fuel filter , eng fuel filter assy , hose , hose , accumulator , pump assy gear , hose assy hyd , hose assy hyd , hose lower , hose pipe , hose assy orfs 0x90 , strainer , element, air breather ( elemento ) , filter line , filter line , element line filter , filter line , spacer , shim , shim , body , head filter , head filter , valve assy , o ring , o ring , o ring pilot line , cap ( p230005 ) , case filter , fitting , pin dowel , grommet , accumulator ( 0.35lt ) , element hyd suction , pin dowel , adapter , pipe clamp , fitting , switch press auto idle 20ps981 2 , switch pressure , switch press, t / alarm , switch, press, a / idl 20ps981 5 , pressure s.w , pressure switch assy , valve shut off , pad rubber , pad rubber , track motor , grommat, trv hyd , grommet , clamp , clamp assy , grommet , clamp , clamp assy , o ring , clamp , clamp hose , clamp hose , clamp , swing motor assy , pipe assy , clamp pipe , head & element assy ( 10 micron ) , clamp pipe , filter, drain ( 10micron ) , head , flange split , check valve assy , element, return filter , spring , cover , fitting , pipe assy , elbow , solenoid 3 , hose assy , hose , hose assy , hose assy. , brake supply valve , seal kit , accumulator , element return , element , air breather , condenser assy , element breather , rcv dozerblade , clamp, arm hyd , cover suction , clamp pipe , stop v / v clamp , clamp pipe , clamp , clamp pipe , air breather , strainer , breather element , fitting , clamp pipe , check valve , check valve , block , valve, port relief , screw coupling , filter last guard , clamp pipe , clamp pipe , stop valve , grommet , swing motor , seal kit , port relief valve , port relief valve ( r340lc 7 ) , clamp pipe , adaptor , plug , plug pf , clamp, boom hyd , block , hose joint block , joint 3 way , cover assy suction , check valve , check valve , brake valve assy , valve reg flow , return hose , plug magnet , strainer suction , regulator flow , regulator valve assy , fuse valve assy velocity , elbow ( 90 ) , connector , gasket, hyd oil tank , connector orfs , nut , nut , steering unit ( ls ) , tilt cylinder assy , pipe wa , connector , elbow , gasket, hyd oil tank , steering unit , regulator valve assy , lift cyl assy ( v350 ) , hose assy , connector orfs , tilt cyl assy ( lh ) , cylinder assy tilt / lh , tilt cyl assy ( rh ) , cylinder assy tilt / rh , bracket , shaft steer wheel , shaft reverse , roller chain , roller chain , hose hyd rubber , hose return , pump gear , down control valve , connector , hose suction , hose hose return , suction hose , gasket , boss , filter line , connector , connector long , pump assy gear , chain assy steering , sprocket steering linkage , chain assy roller , hose lower , bracket mtg , hose return , knob lever , filter suction , filter return , o ring , o ring , hyd pump assy , brake valve assy , valve brake boost , locking valve assy , hose suction , hose hyd rubber , element hyd suction , link , boot spool rubber , pin hose pulley , pin hose pulley , pin hose pulley , pin hose pulley , pump assy main , pump assy hyd , tilt cylinder assy , bracket hyd motor , elbow ( 90 ) , elbow ( 90 ) , hose suction , pipe assy hyd , hose assy hyd , element hyd suction , cap hyd tank , lever 4sp , plunger, 2sp ctl lvr , clamp hose , clamp hose , gear pump assy , steeringunit , tilt cyl assy , steering cylinder , elbow wa , bolt hex , yoke control lever , boot, 2sp ctl lvr , boot, 3sp ctl lvr , knob side shift , cap 2sp ctl lvr , connector long orfs , clamp, hyd piping , hoseassy hyd , bracket , shaft idle , joint assy universal , roller chain , u joint assy , hyd gear pump , priority valve , steering unit , lift cylinder assy , gasket, hyd oil tank , hose assy orfs 0x90 , hose assy , steering cyl assy , hose hyd rubber ( low ) , coupling screw , connector , regulator valve assy ( 35df ) , pulley hose , pipe assy hyd , elbow 90 orfs , pipeassy hyd , hose hydrubber , pipeassy hyd , hose hydrubber , pipe assy return , pipe wa , pipeassy hyd , hyd pump assy , hose assy orfs 0x45 , hose assy ofrs , hose hyd rubber , lever assy attach 1 , lever assy control , elbow orfs 90 , elbow orfs 90 , priority valve assy , pin 2sp ctl lvr , element hyd suction , gasket , pump assly , yoke 2sp ctl lvr , rod , gear pump , lever assy aux / 1 , lever assy aux / 2 , valve manifold , hose rubber low , valve manifold 48v , rcv lh , rcv rh , filter drain , cartrige drain filter , head drain filter , pump main , valve eppr , valve assy 2eppr , valve solenoid , valve assy eppr , valve assy stop lh , valve assy stop rh , strainer assy , pipe wa , hose assy , hose assy , pipe wa , hose assy , hose assy flg 0x90 , hose assy flg 0x90 , hose assy , hose assy , hose assy , hose assy , hose assy , rcv lh , rcv rh , cylinder assy arm , hose assy flg 0x90 , flange wa , pipew.a , pipew.a , pipewa , pipew.a , hoseassy ( hi grade ) , pipewa , cylinder assy arm , cylinder assy bucket , flange hyd, split , switch pressure ( 21bar ) , switch, brake fail or accum , filter line , element assy , gauge sight , boom cylinder assy ( lh ) , boom cylinder assy ( rh ) , hose assy thd , steering unit , hose assy thd , hose assy thd , hose assy thd , hose assy thd , hose assy thd , hose assy thd , hose assy , spacer , washer hardened , clamp , hose rubber , hose assy , bucket cylinder assy ( lh ) , bucket cylinder assy ( rh ) , hose assy , main pump , steering pump , hose assy , clamp tube, ins single , clamp , clamp tube, ins single , clamp , clamp tube, ins single , clamp tube, ins single , clamp , switch pressure ( 5bar ) , switch pressure , switch pressure , washer copper , pipe wa , hose assy , pipe wa , mcv assy , hose assy , hose assy , main pump , rcv lever assy ( 2 spool ) , bucket cyl assy , hose assy , pipe wa lh , pipe wa rh , steering cyl assy ( lh ) , pipe assy hyd , pipe assy hyd , pipe wa , pipe wa , hose assy , elbow ( 45 ) , cut off valve , elbow 90 , switch pressure , brake valve , tube assy ( hl770 7 ) , tube assy ( hl770 7 ) , tube assy ( hl770 7 ) , tube assy ( hl770 7 ) , fan & brake pump ( see note ) , connector orfs , elbow 90, orfs , fan & brake pump , fan & brake pump , pipe wa , pipe wa , hose assy thd ( hl770 7 ) , main pump , hose assy hyd , hose assy , hose assy , main pump , steering unit , fan & brake pump , fan & brake pump , element assy , hose assy , clamp , hose assy , hose assy hyd , steering valve ( ehps ) , pin joint , brake & fan pump , fan & brake pump assy , switch pressure , pin w.a , pin w.a , hose assy , brake valve ( 740~770 7 / a ) , cut off valve , element assy. , element return , valve bypass , o ring , dowel pin , check valve , check valve , strainer suction , strainer suction , switch pressure , pump assy main , shim , rcvlever rh , switch pressure ( suco ) , ring , slipper seal , clamp , seal kit , strainer suction , cover , main pump ( 55 7 / a ) , swing motor unit , check valve , hose suction , hose assy orfs 0x90 , hose assy orfs 0x90 , hose assy orfs 0x90 , hose assy orfs 0x90 , boom swing cylinder , rcv sub assy rh , solenoid valve , solenoid valve , switch pressure ( 19bar ) , switch pressure , tee , travel motor , dozer cyl ( w / o valve ) , turning joint assy , arm cylinder , bucket cyl assy , shaft , seal kit , seal kit, turning joint , strainer , fuel cap assy , turning joint ( r80 7 ) , turning joint , seal kit , hyd suction element , cap assy hyd tank , element return , main pump ( r35z 7&9 ) , tee b type orfs test , hose assy ofrs , hose assy ofrs , swing motor , pedal , pedal rcv , filter line , element line filter , turning joint assy ( r35z 7 &9 ) , seal kit , travel motor assy ( r35z 7 &9 ) , dozer cylinder , boom cylinder assy , arm cylinder assy , bucket cylinder assy , pipe wa , pipe assy , pipe wa , pipe assy , pipe wa , pipe assy , pipe wa , pipe assy , hose assy orfs thd 0x0 , hose assy ofrs , hyd return element , fuel cap assy , hose hydraulic tank , hose hydraulic tank , hose hyd rubber , rcv lh , rcv rh , seal kit, turning joint , valve assy stop , pump main , cylinder assy boom swing , motor assy swing , hydraulic pump suction hose , hose hydraulic tank , hsoe tank to cooler , rcv sub assy rh , lever rcv lh , lever rcv rh , cylinder assy dozer , turningjoint assy , shaft , cover , turning joint seal kit , cylinder assy boom , cylinder assy arm , hose assy orfs thd 0x0 , sponge , suction pipe , suctionpipe , fuel tank wa ( r80 ) , fuel tank wa ( r80 ) 8t , hyd tank wa ( r80 ) , hyd tank wa ( r80 ) 8t , suction pipe , main pump assy , main pump , main control valve ( alpha75 ) , swing motor , reduction gear swing , elbow 90 orfs , hose assy , hose assy , hose assy , hose assy , hose assy , hose assy , hose assy , hose assy , bracket , bracket , pad , hose assy , hose assy , suction pipe , return pipe , hose rubber , hose rubber , hose rubber , hose rubber , return pipe , pipe sub assy return , return pipe , rcvpedal , rcv pedal , rcvlever lh , rcvlever rh , rcvsubassy lh , rcvsubassy rh , tee , connector long , travel motor , track motor assy , travelmotorassy , dozer cylinder assy , dozer cyl assy , elbow 90, orfs, long , rubber t / joint , gasket , boom cylinder assy , boom cyl assy lh , arm cylinder assy , arm cyl assy , arm cyl assy ( new ) , arm cyl assy , bucket cylinder assy , bucket cyl assy , bucket cyl assy , pipe assy , pipe assy ( r80 7 ) , pipe assy , pipe assy ( r80 7 ) , pipe assy , pipe assy ( r80 7 ) , pipe assy , pipe assy , pipe assy , pipe assy ( r80 7 ) , pipe assy , pipe assy ( r80 7 ) , clamp , hdb rock breaker piping kit ( hdb70 ) , hose assy , pipe assy , pipe assy , port relief valve , port relief valve , dozer cyl assy ( r80 ) , dozer cyl assy ( r80 ) 8t , clamp pipe , bracket t / joint , hose assy return , pipe assy , return pipe assy , hose assy , hose assy , hose assy , hose assy , hose assy , bracket r / pipe , main pump , hose assy , hose assy , hose assy , main control valve ( 140 7 / a ) , plug kit ( pf1 / 8 ) , washer spring , tee orfs , tee long , tee run type / test , pressure switch , seal kit , travel motor assy , clamp pipe , pipe assy , pipe assy , hose assy , pipe assy , pipe assy , pipe assy , pipe assy , hose assy , hose assy , hose assy , hose assy , flange split , hose assy , hose assy , hose assy , check valve , check valve , connector , elbow 90 long, orfs , hyd tank wa , strainerassy , pipe suction , cover assy suction , shim ( 1.0t ) , filter drain , cartridge drain filter , head spin filter , element assy , element return , fitting , main pump assy , main pump , main pump , main pump assy , swing reduction gear r340 , elbow 90, orfs , elbow 90 , swing motor unit , swing motor unit , pipe assy , pipe assy , hose assy orfs , hose assy orfsxflg , hose assy orfsxflg, 0x90 , hose , hose assy orfsxflg , hose assy orfsxflg, 0x90 , pipe assy , pipe assy , hose assy orfs, 0x90 , elbow orfs , hose assy flgxflg, 0x90 , hose assy flgxflg, 0x90 , hose assy orfsxflg, 0x90 , hose assy orfsxflg, 0x90 , hose assy flgxflg ( 90x0 ) , hose assy flgxflg ( 90x90 ) , hose assy flg , hose assy flg , bracket boom pipe , bracket , hose , clamp hose , hose , hose assy flgxflg, 0x90 , hose assy , hose assy , pipe w.a , hose assy , hose , hose , hose , hose , hose assy , pipe wa suction , hose assy , hose assy , pipe assy hyd , hose , hose assy , hose assy , hose assy , hose assy , main control valve ( std ) , elbow 90, flange , flange , hose assy orfs, 0x90 , hose assy orfs, 0x90 , hose assy orfs, 0x90 , rod assy , gland , piston , nut lock, bucket cyl , clamp assy band , pipe assy r , pipe assy b , seal kit , tube assy , gland cyl , piston , seal kit , seal kit, dozer cylinder , armcylindersubassy , tube assy arm cyl , rod assy arm cyl ( bush+d / seal ) , gland , piston , clamp assy band ( rd ) , arm cyl , band sub assy arm cyl. , band assy b , clamp assy band ( bs ) , clamp assy band, arm cyl , pipe assy r , seal kit , boom cyl sub assy , tube assy , tube assy , gland , piston , seal kit, arm cyl , seal kit , boom cyl sub assy , tube assy boom cyl , rod assy boom cyl , gland , pipe assy r, rh , seal kit, boom cyl , bucket cyl sub assy , tube assy bkt cyl , rod assy piston &bush , rod assy , gland , band assy , pipe assy r , pipe assy r , seal kit cyl , seal kit, bkt cyl , seal kit , seal kit , seal kit , seal kit , gland , piston , cylinder w / o pipe arm , tube arm cyl r300 , rod assy arm cyl , seal kit , seal kit , cylinder assy without pipe , tube assy cyl , gland cyl , band assy , pipe assy r , pipe assy b , seal kit cyl , tube assy cyl , rod assy piston &bush , gland , piston , piston , seal kit cyl , pipe assy ( rd / rh ) , cyl , pipe assy r rh , gland , pipe assy ( rd ) , cyl , cylinder assy without pipe , tube assy cyl , rod assy piston &bush , gland cyl , pipe assy r , bucket cyl assy seal kit ( r480lc 9 ) , seal kit cyl , pipe assy b, lh , pipe assy b , pipe assy b , pipe assy b, rh , pipe assy rv , rod assy piston &bush , pipe assy rd , tube assy arm cyl , tube assy arm cyl , arm cylinder tube assy , rod assy arm cyl , rod assy arm cyl , arm cylinder rod assy , tube assy , rod assy bkt cyl , seal kit bkt cyl , pipe assy bucket cyl , pipe assy r , seal kit , arm cylinder sub assy ( r340lc 7 ) , piston , seal kit , rod assy bkt cyl , rod assy , rod assy , cylinder assy without pipe , sub cylinder w / o pipe ( r510 above #0046~ , pipe assy b , rod assy, boom cyl , seal kit, boom cyl , seal kit, bucket cyl , eal kit , seal kit, bucket cylinder , pipe assy b lh , seal kit , gland , seal kit , rod assy , seal kit , seal kit ( 5 8, 10 12, 14 16 ) , tube assy lh , seal kit , seal kit , seal kit , seal kit cyl , bearing spherical , seal kit, lift cyl , seal kit, free lift cyl. , seal kit lift cyl , seal kit lift cyl , seal kit cyl , seal kit, tilt cyl , seal kit , seal kit cyl , seal kit , seal kit cyl , piston cylinder , seal kit cyl , seal kit , seal kit tilt cyl , seal kit steering cyl , seal kit, lift cyl , seal kit steering cyl , seal kit, lift cyl , tilt cylinder seal kit , seal kit cyl , seal kit, lift cyl , seal kit, lift cyl , seal kit cyl , seal kit, tilt cyl , rod piston , rod piston , tilt cyl seal kit , bush pin , bushing bucket cyl , bush pin , bush pin , bush pin , bushing pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bush pin , bushing pin , bush pin , bush pin , bush pin , bush pin , bushing dozer blade cyl , bushing dozer blade cyl , bushing dozer blade cyl , bush pin , bush pin , bush pin , bush pin , bush pin , seal kit steering cyl , ring cushion , ring cushion , ring cushion , eye rod , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , ring cushion , cushion ring, boom cyl , ring cushion , ring cushion , ring cushion , ring cushion , cushion ring hx360l , spear cushion , spacer cushion , valve check , valve check , check valve assy , band , band , clamp band , clamp band, arm cyl , band , nut , nut lock , washer lock , lock nut hx360l , spring coil , o ring , ring back up, for o ring , o ring ring back up for , hose assy , control cable , steering pump , air brake valve , booster pump , separator water , exhaust safety valve , water valve , on / off valve , hand brake valve , air brake switch , stop brake air chamber , pipe assy , sight gauge assy , air breather ( sl ) , block , hose , air booster , parking lever assy , battery , nut lock , joint ball , belt fan 8pk1625 , guide valve , gasket cylinder head , seat valve, inlet , seat valve, exhaust , screw rocker , seal valvestem , valve inlet , valve exhaust , rocker assy , tappet , rod push , key woodruff , plate thrust , bolt main cap , bushing camshaft, f , sleeve cylinder , bushing camshaft, m , bushing camshaft, r , plug cam , seal side ( main brg ) , pipe oil jet ( pc nozzle ) , pin, spring , switch oil pressure , plate thrust main , plate thrust , plate thrust , plate thrust , gear assy driven , case assy gear , pump assy, water , o ring , gear assy idle , body assy , bolt w / washer , cap sealing , gear assy driven , gasket oil pump , cover assy , gear head , front seal oil , gasket cover t / g , bearing set main , bearing set main , gasket front plate , gasket gear case , washer spring , housing flywheel , rear seal oil , nut fip , bolt w / washer , gasket, rear 1 , sensor speed , pan assy oil , cock drain oil , washer sealing , plug drain , washer sealing , gasket , gauge oil level , guide oil level gauge , o ring , ring set piston std , ring set piston , ring set piston , piston std , piston , piston , pin piston , ring snap , connecting rod assy , bolt connecting rod , nut connecting rod , bearing con rod std , bearing con rod , bearing con rod , bearing con rod , bushing con rod , crankshaft assy , pin dowel , nut crankshaft , pulley assy crank , sleeve oil seal wear front , plate, baffle , flywheel assy , gear ring fly. , plate thrust idler , gasket inlet , gasket air heater , heater air , gasket , gasket , gasket exhaust , nut lock , stud exh. mfld. , nut exh. mfld , hose air , clamp hose , clamp hose , gasket , stud exh. conn. , turbocharger assy , turbo catridge assy , o ring , spring safety , valve safety , strainer oil , washer , o ring , pipe oil , pipe oil , gasket oil pipe , gasket , bolt eye , elbow , hose oil t / d , connector , cover assy cooler , bolt w / washer , gasket, oil cooler , gasket o / c element , gasket, filter , bolt w / washer , element oil cooler , filter assy, oil , eng oil filter , cover oil , gasket, oil filter , o ring , gasket , ring snap , bearing ball w / p , bearing ball w / p , impeller , shaft w / p , spacer , thermostat , packing , gasket , hose rubber bypass , gasket thermostat , gasket , washer plain , gasket, nozzle , support nozzle , cover nozzle , pipe inj no.1 , pipe inj no.2 , pipe inj no.3 , pipe inj no.4 , hose assy return , t joint , joint three way , hose, fuel , hose fuel , hose, fuel , stud fip , pump assy, injection , flange inj.pump , o ring , joint eye , pipe fuel line , bracket inj.pump , pipe, oil , pipe oil , nozzle assy 105118 6980 bas , holder assy nozzle , tip nozzle , fuel filter assy , bolt connector , gasket , gasket , element assy fuel filter , head fuel filter , washer plain , bolt set , washer , ring snap , puller , o ring , starter assy m008t60471 ( r110 7i ) , lever set , switch assy , pinion set , packing , switch assy , alternator assy , pulley assy , bearing , regulator set , rectifierassy , nut set , bolt w / washer , washer spring , joint ball , nut lock , solenoid , rod , gasket kit overhaul , gasket inlet manifold , o ring , washer sealing , guide valve , seat valve inlet , seat valve exhaust , gasket cylinderhead , seal valve stem , gasket rockercover , ring snap , cartridge assy , cartridge , cap , overhaul gasket kit , pulley water pump , spacer fan , unit thermo , cap sealing , cap sealing , bearing set main std , bearing set main , spindel , fan belt ( 1st:2ea ) , ringset, piston ( std ) , valve inlet , valve exhaust , alternator assy , a / c element ( out ) , cap filler , starter assy , gasket cyl head , jet combustion , glow plugs , seal oil , fan belt , relay, safety , hose radiator , gasket water pump , relay glow , pump assy water , thermostat , pump assy water , element assy , alternator assy , glow plugs , starter assy , fuel feed pump ( r110 7 ) , eng oil filter , a / c element ( in ) , gasket water pump , gasket thermostat , pulley, water pump , eng fuel filter assy , fuel injection pump , solenoid set &nut , water pump pulley , thermostat , gasket thermostat , fan , fan belt , injection pump assy , element sub assy , o ring , bearing, ball , switch, oil pressure , case, rear oil seal , strainer, oil , pump assy, oil , gasket, side cover , cartridge assy, oil , filter oil , fan cooling , filter fuel , sensor assy , pump assy inj , motor assy start , plug , bush camshaft , expansion plug ( 30 ) block , main bearing set , bearing assy thrust , bolt head , gasket cyl head , spacer , main bearing ( us=0.25 ) , bearing thrust ( 0.25os ) , housing assy cover , seal oil , housing gear , bolt stud fip mtg , pump assy lub oil , o ring p20 , o ring p14 , o ring 1a p 7 0 , packing ( 3075 ) , bolt plated , bolt plated , bolt plated , bolt plated , cover filler , pipe , o ring 1a p32 0 , housing flywheel , cock oil drain , bolt ( m8x12 plated ) , lifter engine , seat a valve bridge , head assy, cylinder , guide valve , guide valve bridge , plug , valve ( intake ) , valve ( exhaust ) , spring valve , retainer spring , seal valve stem , seal valve stem , nut ( m8xp1.0 ) , cotter assy , seat nozzle , o ring 1a p12.0 , shaft rocker arm , support a , support b , washer wave , screw valve , arm assy rocker , pedestal retainer , stud ( m8x22 plated ) , retainer f.i.valve , baffle , baffle , diaphragm breather , spring diaphragm , packing bonnet , protector nozzle , manifold air intake , packing ( int.manifold ) , gasket, ( non asb. ) , silencer, suction , gasket , bolt stud ( m8x22 ) exh. conn , gasket silencer , tappet , rod push , camshaft assy , bush idle gear , flange , crankshaft comp , v pulley crankshaft , o ring 1a s53.0 , gear ring , piston w / ring , ring set piston , pin piston , circlip , rod assy connecting , bush piston pin , bolt conrod , metal assy crankpin , bearing pin ( u.s=0.25 ) , piston w / ring ( o.s=25 ) , ring set ( o.s=0.25 ) , dipstick , stud lub.oil filter , filter ( 80*80l ) , sender oil pressure , sael washer 8s , pump assy water , gasket , v belt , case assy thermostat , cover thermostat , gasket thermostat , gasket thermostat , thermostat , gasket ( 8, round ) , gasket, case , clamp , hose b assy water , pipe b cooling water , pulley , valve assy fuel inject , nozzle assy , nut nozzle case , holder assy nozzle , spring nozzle , seat nozzle spring , seal pipe , retainer , pipe assy injection , pipe assy injection , pipe assy injection , pipe assy injection , pipe assy injection , bracket filter , filter fuel oil , pipe assy fuel oil , clamp , pipe fuel oil , pipe assy fuel , pipe assy f.o.return , bolt joint return , packing fuel return , hose joint 4 , pump fuel , separator assy , element ( same as # 119802 55710 ) , ring retaining , o ring ( 1a g 65.0 ) , o ring 1a p 16.0 , alternator assy , bolt ( m8x25 ) , gasket set , nut , bolt plated , relay safety , seal oil , v belt , hose a assy water , pipe assy return c / h f / h , pipe fuel , stopper kit pinion , pully fan , solenoid fuel stop , block assy cylinder , gasket cyl head , sump assy lub oil , bridge assy valve , diaphragm breather , plate center , plate breather , spring diaphragm , gear fuel pump , piston w / ring , ring set pistion , rod assy connecting , bush pistion pin , piston w / ring o.s=25 , clamp 25 , dipsick lub oil , o ring , filter , cooler assy lub oil , bracket oil cooler , pipe hose oil , pipe hose oil , v blet , stopper , o ring , spring , o ring , ring backup , o ring , o ring , ring backup , packing head , o ring , damper assy , feed pump assy , bolt joint , packing case , washer seal , o ring , solenoid stop , valve assy f / injection , nozzle assy ( r80 ) , filter fueloil , pump fuel feed , starting motor , clutch assy , bearing ball , shaft pinion , switch magnetic , spacer , bolt , adjuster belt , bolt , alternator assy , regulator assy i.c , pulley , nut assy, pulley , gasket set , packing bonnet , bracket filter , gasket non asb , bearing main , bearing thrust , oil seal , gasket liquid , oil sump assy r35z 9 , oil seal , exhaust valve , gasket , piston kit eng , pin piston , circlip , rod assy connecting , bushing piston , bearing set conrod , ring set piston , dipstick assy , eng oil filter , filter oil , pump assy water , gasket , fan cooling , thermostat , switch thermo , thermometer , injector , motor assy start , clutch assy starter , v belt , v pulley crankshaft , eng fuel filter , filter corrosion resist ( water ) , feul injection pump , valve intake , fan belt , nozzle assy , shim , pipe fuel , gasket set , belt fan , fan belt , block cylinder , swash plate assy , plate swash , bush tilting, main pump , eppr valve assy with casing , shaft drive ( f ) , bearing roller , bearing needle , bearing spacer , plate set , plate shoe , cover ( fr ) seal , screw , plug , plug , piston servo , stopper large , stopper small , seat ( nsp ) , stopper 1, main pump , o ring , ring back up , ring back up , ring snap , pin , screw set , regulator asy , pumpassy gear , piston assy , cylinder assy ( r ) , plate valve ( rh ) , main pump , cyl. block assy lh , plate valve ( lh ) , main pump , swash plate assy , bush tilting , check 1 assy , seat , check 2 assy , drive shaft ( f ) , drive shaft ( r ) , bearing needle , spacer bearing , plate set , bushing spherical , spring cyl , plate shoe , support , cover ( f ) seal , block valve , screw hex soc hd , piston servo , stopper ( s ) , o ring , o ring , o ring , o ring , seal oil , back up ring , back up ring , nut , ring snap , pin , bolt eye , screw , screw , bearing needle , o ring , o ring , seal oil , plug , shaft drive ( r ) , plate name , relief valve assy , main relief valve , plug, mcv , plug , poppet , poppet , spool by pass cut ( r210lc 7 ) , orifice , spring mcv , spring , spring , screw socket , spool boom 2 ( r210lc 7 ) , spool arm 2 , spool kit bucket, mcv , cover , plug, main pump , plug, mcv , spool travel , spool arm 2 , cover , screw , pin , snap ring , nut , cover block , spring set , spring return , seat spring , spool , piston ( qmc ) , spring pilot , stem ( q ) adjust , seat ( q ) spring , piston pilot , screw ( q ) adjust , cover pilot , sleeve , nut lock , cover ( c ) , spring inner , spring outer, regulator , seat ( c ) spring , rod compensator , piston , plug adjust , plug center , lever 2 , lever 1 , casing , screw , ring snap , socket flange , case front , filter , gear driven , gear drive , nut lock , spring , seat spring , seat , poppet , pin , spring outer , case piston , lever feedback , screw , coupling spline , bushing , spacer , screw , plug , plug , ball steel , gear 1 sun , gear 2 sun , bolt hex , bolt socket m16x170 12.9 , plug pt 1 / 4 , gear sun 1 , plate side 3 , pin 2 , washer thrust , pin knock , gear ring , ring stop , carrier 2 , plate thrust , needle cage, swg rdc gear , bolt , plate cover , spacer , ring stop , ring stop , pin spring swg rdc gear , seal oil , bolt , bearing cyl roller , bearing sph roller , pin knock , washer thrust ( a ) , washer thrust ( b ) , pin no.1 , pin assy no.2 , carrier no.1 , carrier ( 2 ) , swg rdc gear , gear sun no.1 , gear planet no.1 , gear sun no. 2 , gear planet , gear ring , gear pinion , casing front , drive shaftswing rdc , bearing taperroller , bolt wheel , hub wheel , ring / c , carrier , bolt , gear ring , plate torque , o ring , ring retaining / c , shaft planet , washer thrust , bearing needle , gear sun , washer thrust , bushing , stopper , screw , o ring , plug , plate flexible, t / m , square ring, drv axle , bolt hex , stud nut , wheel bolt , spacer , gasket , gear planet , seal oil , o ring , oil seal, drive axle , brake assy , manifold , spacer , bearing set main , pipe dipstick , connector banjo , connector banjo , ring set piston , end tube , gasket , plate lock , insulator vibration , screw cap , hose plain , adapter , gasket , cover rear , head filter , gasket cyl head , bushing , washer seal , seal oil , head filter , tensioner assy belt , cap m / bearing , turbocharger , adapter , filter fuel , o ring , o ring , seal kit ( 1, 5, 13, 16, 18 ) , valve relief , seal kit 1 8 , seal kit , o ring , o ring , o ring , seal kit 61 62 93 , seal kit ( 1, 5, 13, 18 ) , reilef valve , rod tie , rod tie , relief valve assy , relief valve assy , plug spark, head cover , gear ring, flywheel , nut , coil wire , wireset plug , bolt , fitting , regulator , fitting , belt fan , eng oil filter , repair kit regular , repair kit mixer , start motor assy , belt fan , valve air , o ring , joint kit , solenoid complete , handle , rubber boot , plunger kit , joint , plunger kit , spring set return , ???????? ???? , material description , central strip , valve , hand pump , distributor , distributor , valve , level sensor , plug , buffer , left terminal , pulley , left terminal , limit switch body , lever switch , limit switch head , support , support hyd cooler bed , electric level , plug , support , water hose , water hose , air filter , elbow , reduction gear , hose , valve air filter , fan cover , radiator core , cover , fan , engine predisposition , cartridge , airbox , joint , cover , cover , cover , separator , belt 8pk 1939 , tensioner pulley , pump , starter motor , alternator , hand pump , plug , electric level , cover with complete o ring , o ring , pin , jack cylinder parking brake , complete wheel , tyre , tyre , fork , supporting body sx , ball joint , jack , jaw , bearing , joint sx , quad ring , stopper , backstop , backstop rubber conveyor , conveyor , conveyor cradle , cylinder , bushing , lever switch , limit switch head , right hood support , left hood support , backstop , conveyor , conveyor cradle , hardox conveyor cradle , plate , complete pin , tube , shaft , bucket , rim , belt , support , sleeve collar , conveyer motor , plate , lower wheel , screw wash , screw wash , suction fan , cylinder , filter , cylinder , plate , bulkhead , rear slide , seal , left terminal , left terminal , leaflet , proximity , collar , hydraulic engine , valve , orbital engine , valve , seal , solenoid , coil , pipe , rocker arm broom plate , lifting pin , central broon holder cable , central broom chassis , flange , lock cover , complete pin , left holder central broom , central broom hub , central broom , support , support , cylinder , fork , fork , rear sheet backstop , high containment flap , backstop , backstop , side brush casing , plate , slide holder engine side , right slide holder , left terminal , fork , clip , chain , clip , cover rubber , threaded rod , chain , tie rod , pin , bushing , arm , flange , plate side brush , tie rod side broom , attack brush , side brush ø800 ppn+acc , joint , joint , pin , bushing , spring , plate side broom , support plate side broom , sheet , rubber , plate , hinge , hatch , cable lock , lock , cabin chassis , port sx , port dx , frame , seal , manometer conveyor , gauge , pin , bushing , lock , lever , front crystal , crystal less , crystal less sx , sliding window sx , sliding window dx , pin , handle , seal , rod , seat , lock dx , lock sx , bellows , engine , arm , arm , brush wiper , tap , motor fan , filter , filter , kei , bushing , support , washer , valve , hinge , pin , bulkhead , transducer , backstop , pin , tie rod , tie rod , quad ring , ring , brake disc , seal , joint dx , metal ring , felt , supporting body dx , steering rod , engine , rim , cylinder , nut , oil drain filter , filter , o ring , o ring , hook , radiator core , radiator core , diesel engine benz , bulb , elbow , clamp , throttle , exchanger , bulb , hose , metal ring , support , tie rod , distributor , cylinder , grids tail lights , third broom , pressure , pump , guide ( steering orbital valve ) l , pump , valve , solenoid , block , block , brake pedal , pipe , collar , hose , hose connector , nozzle , nozzle holder , filter , pump , float , bibcock , gate , suction pipe belt , micro , clamp , suction pipe , pin , bush , fifth wheel , tie rod front broom , spacer , plate , pin , support plate front broom , support , cylinder , cylinder , cylinder , third broom , stopper , bushing , joint head , headlight , orbital engine , reduction gear , metal ring , metal ring , key , rotation block front broom , coil , solenoid front broom , solenoid , solenoid front broom , valve stem , button , joystick , potentiometer , adaptator , contact , plate , plate , casing chassis left , central casing , right casing , left casing , left casing , right casing , ultra tetratex dust filer pm1. , square , complete pin , secondary side conveyor flap , pinion coupler drive motor , cylinder suspention , rear lever door lock , main dust filter , tetratex pm 1 filter , arm , slide guide plate , center broom chassis , lock cover , left slide , right slide , bulkhead , joint plate side brush , arm side brush , support plate front brush , pin , plate , joint , pin , cylinder side broom , side broom ppl / steel # ø mm 500 , cylinder , lock cylinder third brush , cylinder front brush , cylinder front brush , cylinder front brush , hub conveyor drive side , cover , ring oil seal , ring , shaft , plate , conveyor belt upper crown , conveyer belt upper crown , conveyor cradle top sheet , hardox anti abrasive plate kit , conveyors larger surface palettes , hub , conveyor belt scrape rubber , support plate , suction impeller , rear door cylinder , broom slide holder rh , broom slide holder lh , pvc plate broom , ferrule bush broom , plate , plate , washer , rubber brush side , fillet , central broom holder cable , flap broom , fork , right side slider holder , left side holder , central broom chassis , lock cover , right slide screw rh , left slide screw lh , collector , water spray r / l hand brushes 620l sstank , cylinder steering , moulding joint , support , joint bracket side brush , joint bracket side brush , moulding motor point , side brush arm , side brush support , support plate third brush , support third brush , lever , screw , main broom ppl / steel mm 1300 x 650 ø , locking pin cylinder fb , side brush cylinder , cylinder side brush , pin broom , rim , air intake cyclone vortex pre filter , 90 deg.right hand front pivoting brush , water spraying ext. for front brush , heavy duty rear vaccum wand , trojan acid 12v 95ah battery , macro m40 engine relay kit , vdp seal kit m60 , door stop , brush arm bush , tie rod side brush , rear door lock , belt ac , bearing , seal , bearing housing , bearing , bushing , bushing , bearing conveyor bottom , ring oil seal conveyor , spacer , proximity , tyre 245 / 70 r17.5 , scheda elettronica funzionis01 , brush lifting jack , etl 10p contactor , radio usb with loud speakers , battery switches , ttcx48 unit , lamp front head light , reverse gear light , lamp cabin top head light , pivoting light , button , button movement , switch easy start , button toggle , switch light , side lights , repeated direction , proximity sensor hopper , switch conveyor , microswitch , container limit switch , joy stick third brush , button switch rear axle , vm engine diagnostic tool , button b , proximity sensor rear door , proximity sensor , proximity sensor , proximity sensor f , proximity third brush , cylinder parking brake , sensor broom , vdp pump , engine hyd drive motor , forward / reverse valve , vdp pump , hyd drive motor , m40 side brush motor , gear pump , pump hydraulic , coil work pressure , brake pedal , plug breath , catridge suction s , impeller & vibrator , pump side brush , coil hopper , coil rear door , coil third brush , radiator hyd cooler , traction control unit , coil front brush 24 w , coil front brush 24 w , coil front brush 24w , conveyor hyd block , pump ( water ) , water filter , water valve , swivel jet , jet , water inlet valve , float switch , spring pipe water hose , spring side brush , spring , engine vm m40 , engine coupler , fuel level sensor , exhaust cap , m40 spare pre filter , fuel lever sensor , side brush fork , rear axle left side support ( r ) , fuse 5a , fuse 15a , fuse 20a , compressed air filter , relay , fuse 30a , fuse 40a , 100a lamellar fuse , air conditioner compressor , pressure relief valve , oil filter cap with seal , main broom rotation , side broom speed adjustment , air filter , engine air filter primary cartridge , engine air filter secondary cartridge , coolant hose , coolant hose , coolant hose , coolant hose , main diesel filter , engine oil filter , vm engine belt 5pk 1800 , starter motor engine , fan speed ac , temperature ac , ac control , wiper blade , fuse 125a , fuse 40 a , relay , relay , relay , water jet pipe + nozzle , spray gun , coil side brush , ac controler , knob , insert holder switch ac , grommet kit seal kit hpj , catridge water , conveyor switch , valve centre brush lowering , valve centre brush lifting , oil filter catridge kit , fuel filter ( separator ) , fan radiator volvo , starter volo , alternator , coolant pump volvo , cap fuel filter volvo , cap oil filter volvo , complete left side door , coil vhc 24v 24w , valve tt s2c 00 , hydraulic oil filter , seal kit pump 1 ( 3 stage ) , seal kit pump 2 ( 3 stage ) , seal kit pump32 ( 3 stage ) , side brush bar , engine drive pulley oil seal , o ring , wax coating , air filter , engine temperature sensor , fuel filter water separator , exhaust pressure sensor , fuel filter insert , alternator drive belt tensioner , idler pulley , boost pressure sensor , ac compressor drive belt , engine oil level sensor , oil filter kit , wter in fuel sensor , hp sensor , engine and transmission install , assembly; cooling system , exhaust install , engine mount assy , assembly; fuel system , fuel tank , assembly;air intake , transmission assy , engine;bsiv , fan assembly , fan guard; asy , adapter, bearing , bolt;sems , gauge oil , filter , alternator, assy , belt, fan , assy starter , assy pump, water , gasket, water pump , element, inner , assy element, a / c , assy cover , valve , filter ( cartridge, oil ) , gasket ( muffler ) pump, assy ( fuel ) assy separator element, kit , engine and transmission install , assembly; cooling system , exhaust install , engine mount assy , assembly; fuel system , fuel tank , assembly;air intake , transmission install , engine;bsiv , fan assembly , fan guard; asy , adapter, bearing , bolt;sems , assembly; cooling system , cooling module;bsiv , transmission cooler line , assembly; radiator cooler , assembly; charged air cooler , assembly; auxiliary tank , top heat shield roc , *plate; top heat shield roc , *foam; top heat shield roc , rh heat shield;roc , *plate; rh roc heat shield , *foam; rh side heat shield , lh heat shield;roc , plate; lh roc heat shield , foam; lh side heat shield , foam; top heat shield roc , pipe clamp , tie rod rhs , tie rod bkt rhs , bolt , bolt , bolt , bolt , bolt , replaced by , bolt , bolt , washer , washer , washer;plane , hose; drain roc , clip;hose , clip , bolt , washer;plane , nut , bolt , cover plate , fan assembly fan , assembly; radiator cooler , hose;coolant inlet , hose; coolant outlet , clhose , clip;band , protector , fuel tank assembly , filter , cap assembly , *cap , *chain , fuel float cobo , fuel tank asy , washer;plane , oil strainer assy , washer , bolt , washer;plane , screw;sems , bolt , bolt , spr.washer , bolt , plate , flange cover , oring , bolt , fuel gauge cover , plug, tank bottom cover , washer;sprg , rubber;grommet , o ring , gear lever asy , gear shift switch assy. , replaced by , gear shift sw ( nc ) , replaced by , gear shift sw ( no ) , gear lever assy , replaced by , gear lever assy , nut m12x1.75 , replaced by , nut m12x1.75 , bolt , washer;pln m12 , washer;plane m8 , boot_gear lever , support_rubber boot , bolt m8x20 , hex jam nut , drive train , rear axle installation , propeller shaft assembly , front axle asy , pin asy , shim , spacer , replaced by , spacer , washer , bolt , replaced by , hex bolt , front axle lines grease , steering cylinder grease line , fitting orfs , *packing o ring , o ring , o ring , fitting orfs , *packing o ring , o ring , front axle asembly , front axle & bush asy , *axle assy , *bushing , *bushing , *bushing , tie rod assy , *tie rod , *bushing , *fitting;grease; , hub assembly front wheel , *hub front wheel , *gasket front axle cap , *cap , *washer;sprg m8 , *m8 allen screw , washer;plane m10 , washer thrust , washer thrust , fitting;grease; , pin king , grease nipple , seal pin , bushing , knuckle right , knuckle left , steering cylinder ( w ) , steering cylinder ( l&t ) , pin str cyl , pin tie rod , screw jds19hex , nyloc nut3 / 8 16nc ty p , pin , pin spring , seal oil , replaced by , rotary seal , cup oil seal , cone brg altn , brg cup , cup taper brg , cone brg , washer , wheels ( rims & tires ) , *tyre & tube assembly , * tyre , * tube , *flap , rim , replaced by , rim sub assy , *wheel front steel disk , *special flange , hub nut , replaced by , bolt hub , hub nut , rear wheel hd , *flap code , *tube , *tyre ( tub type ) , *rear rim hd , front rim & tire assembly front rim assy , *rim , *hub nut , wide tyre assembly front wide tyre , tube; front wide tyre , wheels ( rims & tires ) , 9x16 16pr tyre & tube assy , *9.00 x 16 16pr tyre , *9.00 x 16 16pr tube , *flap for 9 16 16pr , rim , hub nut , hub nut , rear wheel hd , *flap code 24v , *tube ( 14x25 tyr ) , *tyre ( tub type ) , *rear rim hd , stabilizer lever assembly , *lever assembly , **knob latch , **clevis assembly kit rh , **clevis assembly kit lh , **nut , **tie rod , **nut , *center bush , *center bolt , *split pin , backhoe lever assembly , *lever assembly lh , *lever assembly rh , *tie rod backhoe , *ball joint , *clevis assembly kit , *knob , *knob , *nut , *nut , *washer , *bolt , *nut , *punch nut , *rubber boot ( b / h levers ) , **boot for b / h levers , **ring for b / h boot , loader lever asy lever asy , fl lever , ac installation , compressor;assembly , condenser_ac , evaporator , ac , belt ac compressor , louver , drier unit_ac , switch blower ac , air distribution box assy , bracket;condenser , cl rh condenser mtg , compressor; bracket asy , bracket_ac drier mtg. , u clamp_ac drier holding , duct ac_evaporator to distribution box , s hose assy;txv to comp , liquid hose assy;cond to rd , liquid hose assy;rd to unit , d hose assy;comp to cond , bolt; compressor mounting , retainer; compressor mounting , m10 x 1.5 , bolt , washer , bolt , clip , clamp , hex bolt , bolt , washer , hex nut , bolt , washer;plane , washer;plane , rubber strap; ac duct , rubber strap; ac duct , duct evaporator , cover , ac evaporator , *cover , ac evaporator , *side cover , *sheet metal clip , *nut;wd , main wiring assembly , chassis 2 harness , engine harness , washer;sprg m8 , horn , bolt m06x016.0 , relay 12v 100a , clip , wire hareness starter alternator , clip 10x1 , clip , clip , clip , washer;plane m8 , bolt m8x20 , bracket fuse link mtg. , grommet; battery relay , rubber pad , clip;band 250 , starter relay , washer;plane m6 , hex nut m6 , hex bolt m6x60 , harness;engine intermediate , cable;earthing , bracket;fuse link , harness;heater , bolt m6x12 , bolt; sems , *bolt m10x20 , *washer m10 , plate , plate , bolt , washer;pln m12 , bolt , bracket; relay , cover; relay , washer;spring;m , cover; fuse link , bracket; fuse link , cover; fuse link , brake pedal assy , pump pin , bracket ast brake reservior mtg , spacer , o ring , washer;plane , hex nut , cap brake reservoir , adapter , clip;hose , washer;plane , bolt , elbow , replaced by , adapter , spacer , bolt , bolt , washer;pln , pin;split , clamp , bearing , spring eye , pedal spring , elbow swivel , break master cylinder , break tank , pedal bolt asy , hose service brake , hose service brake , tube brake assy , tube nut , sleeve , tube brake , brake pedal assy , left pedal asy , right pedal asy , pedals lock , bolt , washer;spring;m , bracket asy , o ring , hose brake , oil tank asy , oil tank , magic eye hydrolines , bolt m12x030.0 , washer m12 , spring , bolt; sems , *bolt m10x20 , *washer m10 , valve , washer;sprg m8 , hydraulic filter , o ring , bolt , bolt; socket m0 , cover , o ring 1ag060 , spr.washer m10 , breather;air , oring , plug tank bottom cover , flange cover , plate , replaced by , hydraulic tank guard , o ring , bolt m10x20 , pump assembly , spr.washer , washer;spring , nut , o ring , plate fitting , *o ring , bolt , bolt;socket , o ring , o ring , fitting , *o ring , replaced by , elbow , *o ring , o ring , hydraulic pump , o ring , adapter flat face seal , *o ring , flange;split , flange split , o ring , block manifold , plug , *o ring , o ring , hydraulic pump , seal kit for pump , *lip seal , *section seal , *seal element , *seal energizer , *o ring , *o ring , load sensing priority valve assembly kit , *load sensing priority valve , *washer , *bolt , seal kit for lspv , *o ring , thrust plate kit , *thrust plate , lspv adapter , steering coloumn assembly screw , steering col weld gasket , valve steering steering , valve assy steering...

Directorate Of Municipal Administration - Maharashtra

38843485 tender for yearly supply and installation of electrical materials, electrical poles, led lights and accessories etc., reparing of led lights/high must for year 2023 24 , supplying and erecting metal clad distribution board 240v, 2 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. sw swr/mdb , supplying, erecting & marking tpmcb 6a to 32a,in provided distribution board as per specification no. sw swr/mcb , supplying, installing, testing and commissioning solar street light pole comprising of 14w led fitting, 12v 36ah maintenance free lithium battery, min. 75wp spv module, ms powder coated battery box weather proof, mounted on 75/80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl (with 5 years warrantee ) , making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr , making trench of suitable width and depth in hard murum / tar road for laying provided lt cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. cw exn ctr , supplying, erecting & terminating xlpe armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al , supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al , supplying, erecting & terminating xlpe armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al , supplying, erecting & terminating xlpe armoured cable 1100 v.3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying and erecting isi mark g.i. pipe pole ‘b’ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (5 + 1.75 + 1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation.(weight 109 kg.) as per specification no.oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no.oh pl/stp , supplying and erecting street light bracket made from 25 mm. dia ‘b’ class g.i. pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt/bpc , supplying & erecting frp box of size 300 x 200 x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wgma/bw , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. eaep , supplying and erecting isi mark gi pipe 25 mm. dia. ‘b’ class at position with accessories complete. specification no. cw plb/gp. , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered,with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete.(for above 9 m poles) , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template,duly plastered as per design complete (for 12.5 m raising lowering high mast). , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. ohpl/opl , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no.ohpl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. ohpl/opl. , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. ohpl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no.ohpl/opl. , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. ohpl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70mm a/f on provided foundation as per specification no. ohpl/ opl , providing & erecting 10 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 175 mm a/f, top 70 mm a/f on provided foundation as per specification no. ohpl/opl , providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm a/f, top 90 mm a/f on provided foundation as per specification no. ohpl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. ohpl/opl , supplying and erecting outdoor stand mounted feeder pillar for highmast of the same manufacturer with 32a tpn mcb incomer, single dial timer switch, 25a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected with cc foundation complete. , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. ohpl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. ohpl/pbkt , supplying, erecting & terminating xlpe armoured cable 3 core 2.5 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no eaep. , supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. , supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non corrosive bond in an approved manner with required joints. as per specification no. eaep. , supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fgodf/fls2 , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf/fls 2. , making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr , supplying, erecting & terminating xlpe armoured cable 2 core 4 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al , supplying and erecting isi mark g.i. pipe pole ‘b’ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gi , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting mains with 2x1.5 sq.mm f.r copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wgma/bw , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. eaep , supplying and erecting isi mark gi pipe 15 mm dia. ‘b’ class at position with accessories complete. specification no. cw plb/gp. , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered,with necessary curing and finishing complete. (for 6 m pole) , supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.cb lt/al , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , ? ?? ?? ?? ?????? ???? ???? ? ?????? ??????? ?? (? ???? ????? ) , ? ? ?? ???????? ????????? ???? ???? (???? ????? ? ??? ?????????? ????? ??? ) , ??????? ???? ?? ???? ???? ???????? ???? (??????? ?? ) , ??????? ???? ??? ??????? ???? ???? (????? ????? ) , ups 800 va , spanner set tool kit box (bosch) , 11 kv discharge rod (3 piece set) , 1.5 sq.mm. 3 core flexible copper wire , led tube light 18 w , exhaust fan 300 mm , air conditioner 2 ton , air conditioner 1.5 ton , air conditioner 1 ton , table fan 400 mm , wall fan 400 mm , ceiling fan 1200 mm , providing anf installation of 1 nos power point (with all material) , providing anf installation of 1 nos light point (with all material) , invertor led lamp 30 w , invertor led lamp 24 w , invertor led lamp 18 w , 40/36 flexible copper wire , armoured cable 2c,25sqmm,aluminium , armoured cable 2c,16sqmm,aluminium , armoured cable 2c,10sqmm,aluminium , armoured cable 2c,6sqmm,aluminium , armoured cable 2c,4sqmm,aluminium , water proof insulation tape , street light led 12 18 w , street light led 26 36 w , cfl holder , pvc insulation tape , main switch with kitkat fuse 100a, 1 ph , main switch with kitkat fuse 63a, 1 ph , 2c, 10 sqmm service wire aluminium , 2c, 6 sqmm service wire aluminium , 2c, 4 sqmm service wire aluminium , 3/20 copper wire , 2.5sqmm flexible copper wire , 1.5sqmm flexible copper wire , mcb 3 ph,63a , mcb 3 ph,100a , mcb 1 ph, 32 a , mcb 1 ph, 63 a , mcb 1 ph, 100 a , mcb 1 ph, 6 a , elcb 63 a/415 , kit kat fuse 100 a , kit kat fuse 63 a , kit kat fuse 32 a , main switch with kitkat fuse 100 a, 3 ph , main switch with kitkat fuse 63 a, 3 ph , main switch with kitkat fuse 32 a, 3 ph , patripeti 2*3 feet (pole box) , patripeti 2*2.5 feet (pole box) , rotor holder for tube rod fitting , drum holder for tube light starter fitting , patrikan for side holder fitting for 40 w tube light , starter for tube light , tube light choke for 40 w (electronic) , tube light choke for 40 w (copper) , tube light rod 40 watt , led lamp 24 watt threaded / pin type , led lamp 30 watt threaded / pin type , led lamp 40 watt threaded / pin type , cfl lamp 85 watt threaded / pin type , aac gnat conductor , aac ant conductor , shockle,shockle patti,shockle nut bolt , gi wire 14 no. , bobin for cable hanging purpose , cfl lamp 65 watt threaded / pin type , stree light tube fixture for 40 w (heavy duty) , top vocer for tube light fixture , tube ligth patti for 40 w , bracket for led light fitting (18 36 w) 4 feet in length (pipe) , khekda clamp for gulder pole of 3*4 inch for 3/4 inch bracket with nut & bolts , street light led 20 25 w , bracket for tube light fixture (pipe) 3/4 inch and 5 feet length , clamp for 3*4 gulder pole (i section) for 3/4 inch bracket size with nut & bolts , clamp for 2.5*3 gulder pole (i section) for 3/4 inch bracket size with nut & bolts , clamp for 2.5*3 gulder pole (i section) for 1.25 inch bracket size with nut & bolts , khekda clamp for gulder pole of 2.5*3 inch for 3/4 inch bracket eith nut & bolts , khekda clamp for gulder pole of 3/4 inch for 1.25 inch bracket eith nut & bolts , ?????????? ? ??.????.? , ????? ??? ??????? (exide ????? ??????? ) , ????? ?? ????? ?? ??????? ????? , ?????????? ???????? , ?? ? ???? , ????? ???? ???? ??????? , repairing of led street light, 20 24 w, (with required material) , repairing of led street light, 26 36 w, (with required material) , repairing of led street light, 40 48 w, (with required material) , repairing of led street light, 60 w, (with required material) , repairing of led street light, 70 75 w, (with required material) , repairing of led ( fiood type ) street light 50 w(with required material) , repairing of led ( fiood type ) street light 70 80 w(with required material) , repairing of led ( fiood type ) street light 90 100 w(with required material) , repairing of led ( fiood type ) street light 120 w(with required material) , repairing of led ( fiood type ) street light 150 w(with required material) , repairing of mini high must 110 watt led (4 nos)flood light , rsj pole 125x70 ,8 mtr long , lt stay set , rsj pole 125x70 ,8 mtr stud...

Military Engineer Services - Maharashtra

38679955 tender for provision of boundary wall with allied works at acquired land at af station ojhar. 1 excavation and earth work 2 surface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and as directed. 3 excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth in depth for foundation etc. and getting out in soft / loose soil complete all as specified and as directed. 4 excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth in depth for foundation etc. or and getting out in hard / dense soil complete all as specified and as directed. 5 excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth in depth for foundation etc. or and getting out in soft / disintegrated rock complete all as specified and as directed. 6 excavation in trenches not exceeding 1.5 metre wide andexceeding 1.5 metre but not exceeding 3.0 metre in depth for foundation etc. and getting out in soft / loose soil complete all as specified and as directed. 7 excavation over areas not exceeding 1.5 metre deep and getting out in soft / loose soil complete all as specified and as directed. 8 excavation over areas not exceeding 1.5 metre deep and getting out in soft / disintegrated rock complete all as specified and as directed. 9 excavation over areas exceeding 1.5 metre but not exceeding 3.0 metre deep and getting out in soft / disintegrated rock complete all as specified and as directed. 10 returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft / loose soil complete all as specified and as directed. 11 removing excavated material ( soil ) notexceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. 12 removing excavated material ( soil ) exceeding 500 metre but not exceeding 1000 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. 13 removing excavated material ( soft / disintegrated rock ) exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. 14 material and labour for filling fine sand to the full width of trenches for protection of cables including spreading and punning down including watering, consolidation complete all as specified and as directed.note : thickness of sand filling shall be the measured after punning. 15 concrete work 16 material and labour for plain cement concrete 1:3:6 type c1 using 20mm grade stone aggregate including weathering, slightly rounded chamfered angles and throating including necessary formwork for coping of electric poles complete all as specified and as directed. 17 material and labour for plain cement concrete 1:4:8 type d2 using 40mm grade stone aggregate as foundation filling and mass concrete complete all as specified and as directed. 18 material and labour for reinforced cement concrete m 25 ( design mix ) using 20mm graded stone aggregate as in footings of columns, plinth beams etc. complete all as specified and as directed. 19 material and labour for reinforced cement concrete m 25 ( design mix ) using 20mm graded stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; etc. complete all as specified and as directed. 20 material and labour for reinforced cement concrete m 25 ( design mix ) using 20mm graded stone aggregate as in columns etc. complete all as specified and as directed. 21 material and labour for reinforced cement concrete m 25 ( design mix ) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 metre span etc. complete all as specified and as directed. 22 material and labour for plain cement concrete 1:2:4 type b0 using 12.5 mm graded stone aggregate as in bed block including forwork complete all as specified and as directed. 23 brick work 24 material and labour for brick work with fly ash bricks ( old size bricks ) , straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. 25 wood work 26 material and labour for use and waste of form work to sides of column footings, column bases, rafts and plinth beams for flat rough finished surface complete all as specified and as directed. 27 material and labour for use and waste of form work to falt faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses etc vertical or to batter for rough finished surface complete all as specified and as directed. 28 material and labour for use and waste of form work to sides of columns for flat rough finished surface complete all as specified and as directed. 29 material and labour for use and waste of form work to sides and soffits of beams, cantilevers, bressumers, lintels over 1.5 m span etc. for flat rough finished surface complete all as specified and as directed. 30 steel, aluminium and iron work 31 material and labour for mild steel tmt steel bars 10mm dia and over cut to length bent to shape required including cranking, bending and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 32 material and labour for mild steel tmt steel bars 5mm dia and over as in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 33 supply and fixing mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars and similar work conforming to fe.290, gde e 265 complete all as specified and as directed. 34 supply and fixing galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossings with and provision of mild steel wire, staples or steel pins etc. complete all as specified and as directed. 35 supply and fixing mild steel screw bolts ( machine made ) with hexagonal or square heads at one end and screwed the other end or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, length of bolt exceeding 22.5 cm but not exceeding 30 cm and dia of neck 10 to 20 mm complete all as specified and as directed. 36 supply and fixing mild steel plates ( plain or chequerred ) , channels square cut or notched ( ordinary and counter sunk ) forming holes with riveted, bolted or welded attachment using steel of grade fe 410 w ( grade e 250 ) quality b complete all as specified and as directed. 37 supply and fixing mild steel posts and struts as in swan neck including tops bent to shape as directed including all necessry drilling, bolting, welding, riveting etc. conforming to fe 290 ( grade e 165 ) complete all as specified and as directed. 38 material and labour for 4 mm dia galvanized steel wire mesh 150 mm x 100 mm, made up into mattresses or cages, lapped, wired and laid in position including closing after filling complete all as specified and as directed. 39 supply and fixing fencing over boundary wall with punched tape concertina coil ( ptcc ) 1050 mm dia all as specified and shown on drawings and fixed with seven horizontal rows of reinforced barbed tape ( rbt ) as specified which is to be fixed between angle 50 mm x 50 mm x 6 mm at every interval of 3 metre centre to centre with wire, stud tied with gi staple & gi clips including all necessary bolts etc. complete all as specified and as directed.note : cost of all items mentioned shall be deemed to be included in the quoted rate of this item except 50 mm x 50 mm x 6 mm angle iron which shall be measured and paid separately. 40 plastering and pointing work 41 material and labour for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. 42 material and labour for forming v grooves in plaster not exceeding 10 mm deep and not exceeding 10 mm on face complete all as specified and as directed. 43 material and labour for washed stone grit plaster in two layers, under layer 12 mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand ) and furrowing the under layer with scratching tool, thereafter applying cement slurry @ 2 kg / square metre on under layer and then applying final 15 mm layer of cement grit plaster 1:1.5:2 ( 1 cement : 1.5 coarse sand : 2 stone chipping of 10 mm nominal size ) in panels with grooves all round as per approved pattern including scrubbing and washing with brushes and water to expose the stone chippings complete all as specified and as directed. 44 white washing, colour washing and distemdering work 45 material and labour for applying two coats of cement based paint over a coat of alkali resistant priming paint on plastered or concrete surfaces of walls including preparation of newly plastered / pointed surfaces complete all as specified and as directed. 46 painting work 47 material and labour for preparation of new or previously untreated steel surfaces of any description over 10cm width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 48 miscellaneous b / r items 49 material and labour for hdpe pipes pn 10, 100 mm dia fixed in rcc wall complete all as specified and as directed. 50 material and labour for 25 mm thick pre formed bituminous filler ( mastic pad ) as in expansion joints complete all as specified and as directed. 51 supply and fixing 150 mm bore upvc pipes of pressure rating 10 kg f / sq cm, single socketed in any length fixed in walls as in weep holes complete all as specified and as directed. 52 material and labour for cutting road pavement / hard standing by manually and making good the disturbed surface to match with the existing surface complete all as specified and as directed. 53 electrical work 54 supply and fixing factory made un reinforced precast concrete cable cover class lv type 1 flat of size 250 mm x 150 mm x 40 mm complete all as specified and as directed. 55 material and labour for replacement of gi tubing light grade 40 mm bore for passing through cables under the floor along the wall or along the pole complete all as specified and as directed. 56 supply and laying lt cable xlpe insulated, armoured, heavy duty with stranded aluminium conductor, 1100 volts grade of cross sectional area 10 sq mm, 2 core complete all as specified and as directed. 57 supply and erecting steel tubular swages pole complete with cast iron base plate, finial taper plug, nuts, bolts, screws, pole type 410 sp 31 ( 9 metre long ) complete all as specified and as directed. 58 supply and fixing led street light fitting 35 watt, 230 v, ac outdoor type with high pressure die cast aluminium housing and heat resistant glass complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics with ip 65 / 66 protection complete all as specified and as directed. 59 supply and fixing single piece moulded pvc box of size 230 mm x 185 mm x 110 mm outer dimension with and including provision of one mcb sp 16 amps & one 4 way connector including all necessary fixing arrangements to fix to pole i.e. clamps, nuts, bolts & washers of suitable size complete all as specified and as directed. 60 supply and fixing in repairs street light brackets with 40 mm dia gi tubing light grade, 1.2 metres length, bent to shape required including fixing with suitable ms clamps made out of 40 mm x 3 mm, nuts, bolts, washers etc. and fitted on lt poles / walls complete all as specified and as directed. 61 material and labour for pvc 3 core, 1.5 sq mm flexible copper cable for connection from junction box to street light including suitable lugs, pvc conduit etc. required at site complete all as specified and as directed. 62 material and labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buired directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, connected to gi wire 4 mm dia through 15 mm bore light grade gi pipe by means of bolts, nuts, check nuts and washers of galvanized iron or steel with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm bore medium grade gi tubing including funnel, wire mesh, rcc pit cover and pcc chamber pit with 1:2:4 type c1, including excavation and earth work all as shown in electrical plate no 3 of ssr part 1 2009 connected to earthing test point complete all as specified and as directed. notes : ( i ) the end point connection of earthing shall be carried out with the help of gi bolt grouted and washer and nut all as directed. ( ii ) 4 mm dia gi wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode shall be deemed to be included under this item and additional earth wire & protection pipe etc. if any required at site shall bemeasured and paid for separately. 63 demolition and dismantling work 64 dismantling posts ot struts ( steel or rcc ) any section including taking out embedded portion and making good disturbed ground, posts embedded in cement concrete complete all as specified and as directed. 65 dismantling fencing wire mesh of any type / description complete all as specified and as directed. 66 dismantling galvanized barbed wire of any dia / type complete all as specified and as directed. 67 dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed....

Mazagon Dock Limited - Maharashtra

38543260 tender for server room and ups room renovation at primary and near dr site in submarine division, mdl, mumbai 1 biometric access control ( finger ) 2 fire suppression system ( novec 1230 ) 3 spares ( fire suppression system ) 4 vesda system 5 fire retardant partition 6 fire alarm system ( addressable ) 7 environmental monitoring system 8 3 ton pac ( precision air conditioner ) 9 comprehensive warranty of 2 years 10 supplyinganderectingminifeeder pillar triple pole with200a fpmccb as incomer and2 outgoing circuits with hrc fuse base and cartridge of 100aconsists ofaluminium bus bar500 v200 acomplete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per specification no. sw swr / mfp 11 supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous12.97 sq. mm. ( 8 swg ) g.i. earth wire completeerected with glands 12...

Rural Development Department - Maharashtra

38515052 supplying electrical materials and repairs maintenance services at. grampanchayat nimgaon, tal. khed, dist. pune , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) , supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying,tpmcb 40a to 63a in provided distribution board , providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) , supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , nut bolt , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , cable joint kit upto 16 sq. mm cable , street light pole box frp , street light pole clamp round type , supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) , servicing and primary maintenance for street light pole.. , light pole painting , 26w led light to 100w led light repairing , old pole shifting , rework and foundation work per pole , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no , supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 , solar battery bracket , solar battery box high quality… , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , distilled water (1 ltr.) , panel frame for old pole , solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. , providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. , supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs , supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) , supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. , supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. , providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep , supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. , dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. , supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. , supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. , supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. , 18 wtt. led bulb , 24 w. led bulb , 30 w. led bulb , supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Reserve Bank Of India - Maharashtra

38472325 sitc of approved make occupancy sensor to the false supply, installation, testing and commissioning ( sitc ) of approved make occupancy sensor to the false ceiling in the cabin with required hardware. rate shall include for sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 2 2 primary point sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 3 3 secondary point supply, installation, testing and commissioning ( sitc ) of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 4 4 lighting and raw power mcbdb supply, installation, testing and commissioning of approved make 3 phase, 12 way per phase isolation double door metallic mcbdb with per phase isolation kit using required hardwares in concealed manner by making opening in wall and refilling the area surrounding to it by mortar 5 5 sitc of approved make 4c by 16 sqmm copper conductor supply, installation, testing and commissioning of approved make 4c x 16 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth wire with required support from ceiling 6 6 termination of above cable using required size brass cable gland termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. rate shall include for termination of both gi wire at two separate points. 7 7 supply and installation of gi perforated cable tray supply and installation of gi perforated cable tray of minimum 18 swg thick, 100 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod, nut, washers, anchor fasteners and 18 swg gi ?c? channel for support to cable tray at required interval 8 8 supply and installation of gi perforated cable tray of minimum 18 swg thick supply and installation of gi perforated cable tray of minimum 18 swg thick, 150 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod, nut, washers, anchor fasteners and 18 swg gi c channel for support to cable tray at required interval as per site condition. rate shall include for any other material required for completion of this work. 9 9 supply and installation of approved make 2c x 1.5 sq mm copper conductor supply and installation of approved make 2c x 1.5 sq mm copper conductor pvc insulated fire alarm armoured cable with required support from ceiling. 10 10 sitc of approved make 6 module flush mounted aluminium factory finish popup box supply, installation, testing and commissioning of approved make 6 module flush mounted aluminium factory finish popup box with back protecting cover on workstation / side table in the cabin and suitable size plastic white plates with frame, minimum 6 amp sp one way switch qty 03 nos, 16 amp led indicator sp one way switch qty 01 no., 6 amp 3 pin socket qty 01 no 11 11 power plug point supply, installation, testing and commissioning of power plug point using approved make and model suitable size plastic white plates with frame, 16 amp led indicator switch & 6 / 16 amp socket, interconnecting wires and approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 12 12 group of two light plug point supply, installation, testing and commissioning of group of two light plug point using approved make and model suitable size plastic white plates with frame, minimum 6 amp switch qty 02 nos & 6 amp socket qty 02 nos, interconnecting wires and approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 13 13 ups supply mcbdb supply, installation, testing and commissioning of approved make 14 way spn double door metallic mcbdb using required hardwares in concealed manner by making opening in wall and refilling the area surrounding to it by mortar, with the followings. rate shall include for removing of existing mcbdb 14 14 air conditioning power supply mcbdb supply, installation, testing and commissioning of approved make three phase, 6 way per phase isolation double door metallic mcbdb with per phase isolation kit using required hardwares in concealed manner by making opening in wall and refilling the area surrounding to it by mortar, with the followings. rate shall include for removing of existing mcbdb. incomer: fpmcb 63 amp qty 01 no. outgoing: dprccb two pole two module 40 amp 100 ma qty 03 nos. spmcb ?c? curve 20 amp qty 06 nos. 15 15 sitc of approved make 4c x 4 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable supply, installation, testing and commissioning of approved make 4c x 4 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth wire on wall using heavy duty gi saddles ( minimum three nos. in a length of 1 mtr ) or required support from true ceiling with required hardwares, 16 16 sitc of approved make 3c x 2.5 sq mm copper conductor xlpe frls supply, installation, testing and commissioning of approved make 3c x 2.5 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 12 swg gi earth wire on wall using heavy duty gi saddles 17 17 termination of above cable using required size brass cable termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. 18 18 plug point for ac supply, installation, testing and commissioning of approved make single phase 20 amp metal clad dpmcb, plug, socket box, in flush / surface manner as per site condition and 20 amp dpmcb, 20 amp metal clad top. 19 19 ups power dpmcb in ms enclosure supply, installation, testing and commissioning of approved make 16 amp dpmcb and required size metal enclosure in flush / surface manner as per site condition. 20 20 telephone point sitcof approved make 2 pair 0.5 mm dia copper conductor pvc insulated and sheathed urarmoured telephone cable from mdf to each cabin and work station partly in existing floor trunking and partly in partitions of cabin / work station. rate shall include for sitc of approved make two module plastic white plates with frame and two nos rj11 shuttered telephone socket and termination of cable at both ends 21 21 network point supply, installation, testing and commissioning of approved make utp cat 6 cable from network switch to io point of each cabin and work station partly in existing floor trunking and partly in partitions of cabin / work station. rate shall include for termination of cable at both ends with required rj45 terminals 22 22 call bell point supply, installation, testing and commissioning of approved make and model plastic white plate and bell push and indicator type resettable call bell in flush manner and 3 nos 2.5 sq mm wire in pvc conduit partly in partition of cabin and above false ceiling. 23 23 telephone mdf supply, installation, testing and commissioning of 100 pair powder coated mdf with 10 nos 10 pair krone module, stainless steel krone module stand in flushed manner with required mortar etc 24 24 carefully removing of all mcbdbs carefully removing of all mcbdbs, cables, wires, telephone mdfs, if any on the floor as directed by bank?s engineer and as per site conditions....

Inter-University Centre For Astronomy And Astrophysics - Maharashtra

38307780 supply, laying and termination of cable , supplying, erecting/laying & terminating xlpe armoured cable 4 core 70 sq. mm. stranded copper conductor with continuous8.35 sqmm g.i. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe/cable tray as per specification no. cb lt/cu. it shall include labor cost fabrication work(if required) and all required auxiliary accessories. => limited...

Rural Development Department - Maharashtra

38306106 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Mazagon Dock Limited - Maharashtra

38243537 tender for server room and ups room renovation at primary and near dr site in submarine division, mdl, mumbai 1 biometric access control ( finger ) 2 fire suppression system ( novec 1230 ) 3 spares ( fire suppression system ) 4 vesda system 5 fire retardant partition 6 fire alarm system ( addressable ) 7 environmental monitoring system 8 3 ton pac ( precision air conditioner ) 9 comprehensive warranty of 2 years 10 supplyinganderectingminifeeder pillar triple pole with200a fpmccb as incomer and2 outgoing circuits with hrc fuse base and cartridge of 100aconsists ofaluminium bus bar500 v200 acomplete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per specification no. sw swr / mfp 11 supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous12.97 sq. mm. ( 8 swg ) g.i. earth wire completeerected with glands 12 supplyinganderectingtriplepoleand neutraldistribution board ( tpndb ) surface / flushmounted sp / tp of 24 poles / 8 ways on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb 13 providing & erecting 3 pole mccb upto 100a, 415v, with short circuitrating 25 ka ( ics=100% of icu ) , adjustablethermal ( overload ) setting and fixed magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, in provided enclosure on iron / gi frameas per specification no. sw swr / mccb 14 supplying, erecting & marking tpmcb 6 a to 32a inprovided distribution board as per specification no. sw swr / mcb 15 supplying, erecting & marking tpmcb 40a to 63a inprovided distribution board as per specification no. sw swr / mcb 16 supplying, erecting & terminating xlpe armoured cable 3½core70sq. mm. aluminium conductor withcontinuous8.35 sq. mm. ( 10 swg ) g.i. earth wire completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al 17 supplying, erecting& terminating xlpe armoured cable 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / cu 18 supplying, erecting& terminatingxlpe armoured cable 4 core6 sq. mm. copperconductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / cu 19 supplying & erecting original 1.25 mm crca sheet metalenclosures with 30a, 3 pin plug & earth socket and 30 a 3 pin plug top with 30a triple pole mcb complete erected on angle iron / gi frame. 20 supplyingand erecting single pole and neutral distributionboard ( spndb ) with door surface / flush mountedwith 2 polesfor incoming and 10 poles for outgoing sp mcb’son iron / gi frameas per specification no. sw swr / mcbdb 21 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 22 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 23 point wiringfor independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and requiredaccessories as per specification no: wg pw / sw 24 secondary point wiring for additionallight / bell point inpointpvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr / frlsh grade copper wire with required accessories as per specification no: wg pw / sw 25 supplying and erecting pvc surface modular switch box withdouble mounting & front plate for 8 modules complete duly connected. 26 supplying and erecting isi mark modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 27 supplying and erecting isi mark modular type switch 16a dulyerected on provided plate and box with wiring connections complete. 28 supplying and erecting isi mark modular type 3 pin 6a multisockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 29 supplying and erecting isi mark modular type 3 pin 6 / 16amulti socket with safety shutter, duly erected on provided plate and box with wiring connections complete 30 supplying and erecting triple pole metal clad switch andfuse 415v, 100a on angle iron / gi frame as per specification no. sw swr / mtp. 31 supplying, erecting & terminatingxlpe armoured cable 3½core50 sq. mm. aluminium conductor withcontinuous5.48 sq. mm. ( 12 swg ) g.i. earth wire completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al 32 supplyingand erecting single pole and neutral distributionboard ( spndb ) with door surface / flush mountedwith 2 polesfor incoming and 10 poles for outgoing sp mcb’son iron / gi frameas per specification no. sw swr / mcbdb 33 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) inprovideddistribution board as per specification no. sw swr / mcb 34 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 35 providing & erecting hot dipped galvanized cover suitablefor perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner. 36 supplying and erecting fr grade, pvc armoured multimodeoptical fibre cablewith 6 fibres, with core dia 50 / 125 μm ( om3 ) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall / ceiling or laid in provided pipe / trench as per specification no. wg coc / ofc lszh 37 supplying & laying hms pvc conduit 20 mm dia. withnecessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc....

Directorate Of Municipal Administration - Maharashtra

38198295 tender for rate contract estimate for the day to day electrical work need to carry out for operation and maintenance of ichalkaranji city 1 supplying and erecting rolled steel joist ( girder ) pole 150 x 80 mm / 150 x75 mm ( 14.9 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 2 supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with polecap, base plate in provided foundation as per specification no. oh pl / gip 3 supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with polecap, base plate in provided foundation as per specification no. oh pl / gip 4 supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessaryfittings complete as per specification no. ff pp 5 supplying and erecting g.i. pipe ‘c’ class erw 25 mm dia with necessaryfittings complete as per specification no. ff pp 6 supplying and erecting g.i. pipe ‘c’ class erw 50 mm dia with necessaryfittings complete as per specification no. ff pp 7 supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessaryfittings complete as per specification no. ff pp 8 supplying and erecting g.i. pipe ‘c’ class erw 75 / 80 mm dia with necessary fittings complete as per specification no. ff pp 9 supplying and erecting gate / garden light fitting with 200mm dia. glass bowlsuitable for upto 12w led lamp on provided pipe as per specification no. fg odf / glt 10 supplying and erecting gate / garden light fitting with 300mm dia. glass bowlsuitable for upto 12w led lamp on provided pipe as per specification no. fg odf / glt 11 supplying & erecting integral post top lantern fixtures ( mushroom type ) suitable for led lamp upto 12 w consisting of clear acrylic top cover, castaluminium pole cap complete with accessories on provided pole / bracket as per specification no. fg odf / ptl 12 supplying & erecting integral post top lantern fixtures ( globe type ) suitablefor led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole / bracket as per specification no. fg odf / ptl 13 supplying & erecting integral post top lantern fixtures ( light house type ) suitable upto led 18 w lamp consisting of combination of spun aluminiumcanopy & clear acrylic top cover, cast aluminium pole cap on provided pole / bracket as per specification no. fg odf / ptl 14 supplying and erecting integrated led highbay fitting 70w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min.10000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 15 supplying and erecting integrated led highbay fitting 100w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min. 15000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 16 supplying and erecting integrated led highbay fitting 135w ip65 & ik08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of min. 20000 lumens, min.efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf / fls2. 17 supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt / bpc 18 supplying and erecting street light bracket for erection of double fittingmade from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt / bpc 19 supplying and erecting street light bracket for erection of single fitting ontubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe alongwith pole cap of 125mm dia 600 mm long duly welded as per specification no.fg bkt / bpc 20 supplying and erecting street light bracket for erection of double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no.fg bkt / bpc 21 supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 22 supplying and erecting electronic type driver for outdoor led fittings 26w 45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 23 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operat 24 supplying and erecting electronic type driver for outdoor led fittings 76w 100w suitable to operate 25 supplying and erecting double pole metal clad switch with hc fuse and neutral link 240v, 16a on iron / gi frame aperspecification no. sw swr / mdp. 26 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / giframe as per specification no. sw swr / mdp . 27 supplying and erecting porcelain base iron clad cut out hc type 415v, 16aerected on polished wooden block. 28 supplying and erecting triple pole metal clad switch and hc type fuse 415v, 16a on iron / gi frame / board perspecification no. sw swr / mtp. 29 supplying and erecting triple pole metal clad switch and fuse 415v, 32a on iron / gi frame as per specification no.sw swr / mtp. 30 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specificationno. sw swr / mtp. 31 supplying and erecting porcelain base iron clad cut out hc type 415v, 32aerected on polished wooden block. 32 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 33 supplying and erecting hc pattern porcelain fuse bridges with base & hc typefuse links 240v, 32a erected on polished wooden block. 34 supplying & erecting fuse bridges with base hc type fuse links 240v, 63aerected on polished wooden block. 35 supplying and erecting isi mark pwd / msedcl make apprved 63*415 vmainswitch action rod 36 remedial action / troubleshuting of supply in occasion of short circuit fault on ovehead line condutor forrestoration of supply in street light or other electrification work by using hydruli platform / manually including changing jumper / sag in line / change shackle, spacer etc. with proior approval of msedcl competant authority 37 providing temporary 2 x 2 / 4 / 6sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required accessories continuous 8 swg g.i. earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary. 38 supplying and erecting integrated led highbay fitting 150w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty 39 supplying and erecting integrated led highbay fitting 200w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 24000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty 40 labour charges & hydraulic vehicle charges for maintainance of tiranga led strip 41 visiting charges for attending fault of electrical equipments / devices, wiring short circuit faults 42 visiting charges for attending fault of air conditioning unit / generator of imc 43 supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 44 supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 45 supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce 46 supplying & laying ( including excavation ) reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 47 supplying & laying ( including excavation ) half round reinforced cement concrete pipe of150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 48 supplying & laying ( including excavation ) reinforced cement concrete pipe of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc.complete. 49 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 50 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 51 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 52 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 53 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 54 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 55 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 56 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 57 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 58 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 59 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 60 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 4 core 70 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 61 re erecting pvc / xlpe armoured cable 2 to 4 core up to 50 sq. mm. on wall with necessary material & g.i. earth wire. 62 supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 63 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 64 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 65 supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 66 supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 67 supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 68 supplying and erecting mains with wp 4 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 69 supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvcinsulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 70 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvcinsulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw 71 supplying and erecting pvc insulated pvc round sheathed 1 sq.mm ( 32 no. x 0.20mm dia. ) 3 core flexible multi stranded copper industrial cable for voltagegrade up to 1.1 kv 72 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 73 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 74 supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 75 supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 76 supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 77 supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 78 supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 79 supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 80 supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 81 supplying, erecting & marking dpmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 82 supplying, erecting & marking tpmcb 6a to 32a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 83 supplying, erecting & marking tpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 84 supplying, erecting & marking fpmcb 6a to 32a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 85 supplying, erecting & marking fpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 86 supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 87 supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 88 supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 89 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 90 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 91 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom ism channel 75x40x6mm and 550mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 92 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. ofprovided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 93 supplying & erecting ms pole bracket for lt oh conductor fabricated from65x65x6 mm section, 550mm long for necessary nos. of provided insulatorsand erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 94 supplying & erecting ms pole bracket for lt oh conductor fabricated from65x65x6 mm section, 1100mm long for necessary nos. of provided insulatorsand erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 95 supplying and erecting all aluminium stranded conductors 7 / 2.21complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 96 supplying and erecting all aluminium stranded conductors 7 / 3.10 complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 97 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 98 supplying and erecting aluminium bobbin with g.l. ( shackle ) strip, nuts complete. 99 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7 / 10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete. 100 supplying and erecting g.i. wall hook, 10 to 15mm dia and overall length 250mm including grouting, cement plastering etc. complete. 101 supplying and erecting guarding loop using g.l. wire no. 8 swg for lt oh line of horizontal formation erected with 20swg g.l. wire as binding wire and 50mm section on each side complete. 102 supplying and erecting pole clamp made from 50 x 10mm ms flat for pole or pipe, post complete erected with 15mm bolts and nuts, complete duly painted with one coat of redoxide and two coats of aluminium paint. 103 supplying and fixing ms base plate 30x30x0.6 cm size fixed to the pole base either by welding or by set screws 12mm. dia fixed at position. 104 dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level 105 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concretefoundation and making the site clear by refilling the pitswith excavated materials and bringing it to the ground level. 106 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 107 dismantling the existing lightning arrestor set, insulator from dp structure complete. 108 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 109 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep 110 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 111 providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep 112 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification noea ep. 113 supplying and erecting gi wire of high purity of required sizes used for earthingor any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws complete. 114 making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( for 6 m pole ) 115 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) 116 making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) 117 making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. ( cost of wooden box is included ) ( for pumps ) . 118 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 119 making cement concrete foundation in 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing for complete. ( pole muffing or any other purpose ) . 120 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 121 making m 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 122 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal / conical gi pole ) . 123 supplying and erecting gi sheet 1.25 mm ( 18 swg ) having zinc coating of350 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2coats of enamel paint. 124 supplying and erecting marine ( waterproof ) plywood 18 / 19 mm thick fixed towall or on provided panel board with necessary materials such as screws, wallfasteners, supports, nut bolts etc. complete with compliance to is 720:2010 125 supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 126 supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority 127 supplying and erecting static energy meter with 240v 50 hz. ac supply 5 to 30 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display kwh, kvah, v, i, pf, frequency, kw, kva, six months history of energy & md in kw & kva ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. 128 supplying and erecting static energy meter with 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display kwh, kvah, v, i, pf, frequency, kw, kva, six months history of energy & md in kw & kva ) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. 129 supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw ) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company 130 supplying and erecting static energy trivector meter 440 v 50 hz. 20 100a isi mark meter ac 3 phase 4 wires lcd / led display ( measuring and display trivector, v, i, kw, pf, hz, last month history of kwh & md in kw ) with special features like tod, tamper logging, optical communication port & display in absence of power complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested for class 1.0 accuracy by electric supply company. 131 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as perspecification no. cb jt / lt 132 providing & erecting epoxy straight through joint outdoor / indoor for ltxlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt / lt 133 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt / lt 134 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as perspecification no. cb jt / lt 135 providing & erecting epoxy straight through joint outdoor / indoor for lt xlpe armoured cable 300 sq mm., with necessary material as per specificationno. cb jt / lt 136 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt / lt 137 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 25 to 50 sq.mm. cable, with necessary material as per specification no.cb jt / lt 138 providing & erecting epoxy outdoor / indoor end termination kit for ltxlpe armoured cable 70 to 120 sq mm., with necessary material as perspecification no. cb jt / lt 139 providing & erecting epoxy outdoor / indoor end termination kit for lt xlpe armoured cable 150 to 185 sq.mm. cable, with necessary material as per specification no.cb jt / lt 140 providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as perspecification no. cb jt / ht 141 providing and erecting heat shrinkable outdoor termination kit for 11 kv ( e ) xlpe ht cable 3x120 to 185 sq. mm. with necessary material as per specification no. cb jt / ht 142 providing and erecting heat shrinkable out door termination kit for 11 kv ( e ) xlpe ht cable 3 x up to 95 sq. mm. with necessary material as perspecification no. cb jt / ht 143 supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kva capacity online pure sine wave ups, with backup time of .......hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups 144 supplying, erecting, testing and commissioning of 2kva capacity online puresine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 145 supplying, erecting, testing and commissioning of 3kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 146 supplying, erecting, testing and commissioning of 6kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 147 supplying, erecting, testing and commissioning of 10kva capacity online puresine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. ap ups 148 supplying and erecting 12v / 80ah to 88ah tubular battery with battery terminalwire, duly charged with 36 months warranty complete. 149 supplying and erecting 12v / 100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 150 supplying and erecting 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 151 supplying and erecting 12v / 180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 152 supplying and erecting 12v / 200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 153 supplying and erecting 12 v / 65ah smf battery with battery terminal wire, dulycharged complete with 24 months warranty complete 154 supplying and erecting 12v / 100ah smf battery with battery terminal wire, dulycharged with 24 months warranty complete. 155 supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “on” and switching“off” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit led continuous time display, relay output 230 v / 10a with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided m.s. box. 156 supplying and erecting four pole power contactor 430 v, 16 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 157 supplying and erecting two pole power contactor 230 v, 32 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 158 supplying and erecting four pole power contactor 430 v, 40 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 159 painting of pipe pole up to 6 m length along with street light / polebrackets / clamps etc by scrapping the existing paint complete as perspecification no cw ptg / ptp. 160 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp 161 powder coating of approved colour shade on both sides of provided iron work / ms / crca sheet steel work complete including anti rust treatment complete. 162 epoxy painting on both side of approved colour shade of provided iron work / ms / crca sheet steel work complete along with anti rust treatment complete. 163 supply and erection of new pole erection / shifting pole or overhead / underground cables msedcl quotation under 1.3% ddf scheme ( incl tech. sanction+supervision charges ) ...

Rural Development Department - Maharashtra

38064200 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38003871 supplying electrical materials and repairs maintenance services at. grampanchayat wasuli, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38002584 supplying electrical materials and repairs maintenance services at. grampanchayat sawardari, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying,tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l/t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker (1 hours) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water (1 ltr.) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac 59 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 60 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 65 supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. ...

Reserve Bank Of India - Maharashtra

37872535 sitc of approved make occupancy sensor to the false supply, installation, testing and commissioning ( sitc ) of approved make occupancy sensor to the false ceiling in the cabin with required hardware. rate shall include for sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 2 2 primary point sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 3 3 secondary point supply, installation, testing and commissioning ( sitc ) of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 4 4 lighting and raw power mcbdb supply, installation, testing and commissioning of approved make 3 phase, 8 way per phase isolation double door metallic mcbdb with per phase isolation kit using required hardwares 5 5 sitc of approved make 4 by 16 sqmm copper conductor supply, installation, testing and commissioning of approved make 4c x 16 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth wire with required support from ceiling 6 6 termination of above cable using required size brass cable gland termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. rate shall include for termination of both gi wire at two separate points. 7 7 supply and installation of gi perforated cable tray supply and installation of gi perforated cable tray of minimum 18 swg thick, 100 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod 8 8 supply and installation of gi perforated cable tray of minimum 18 swg thick supply and installation of gi perforated cable tray of minimum 18 swg thick, 150 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod, nut, washers, anchor fasteners and 18 swg gi c channel for support to cable tray at required interval as per site condition. rate shall include for any other material required for completion of this work. 9 9 supply and installation of approved make 2c by 1.5 sq mm supply and installation of approved make 2c x 1.5 sq mm copper conductor pvc insulated fire alarm armoured cable with required support from ceiling. 10 10 assembly, installation, testing and commissioning of track light assembly, installation, testing and commissioning of track light fittings supplied by bank. 11 11 installation, testing and commissioning of led downlighter installation, testing and commissioning of led downlighter supplied by bank. rate shall include for providing marking to false ceiling. 12 12 installation, testing and commissioning of 2 x 2 led installation, testing and commissioning of 2 x 2 led panel supplied by bank. to grid type false ceiling. 13 13 installation, testing and commissioning of hanging light installation, testing and commissioning of hanging light fitting supplied by bank. 14 14 profile light fitting installation, testing and commissioning of profile light fitting supplied by bank. 15 15 sitcof approved make 6 module flush mounted aluminium factory finish popup box supply, installation, testing and commissioning of approved make 6 module flush mounted aluminium factory finish popup box with back protecting cover on workstation / side table in the cabin and suitable size plastic white plates with frame 16 16 power plug point supply, installation, testing and commissioning of power plug point using approved make and model suitable size plastic white plates with frame, 16 amp led indicator switch 17 17 group of two light plug point supply, installation, testing and commissioning of group of two light plug point using approved make and model suitable size plastic white plates with frame, minimum 6 amp switch qty 02 nos 18 18 ups supply mcbdb supply, installation, testing and commissioning of approved make 12 way spn double door metallic mcbdb using required hardwares in concealed manner by making opening in wall and refilling the area surrounding to it by mortar 19 19 air conditioning power supply mcbdb supply, installation, testing and commissioning of approved make three phase, 4 way per phase isolation double door metallic mcbdb 20 20 sitc of approved make 4c x 4 sq mm supply, installation, testing and commissioning of approved make 4c x 4 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth 21 21 sitc of approved make 3c x 2.5 sq mm supply, installation, testing and commissioning of approved make 3c x 2.5 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 12 swg gi earth wire on wall using heavy duty gi saddles 22 22 termination of above cable using required size brass cable gland termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. 23 23 plug point for ac supply, installation, testing and commissioning of approved make single phase 20 amp metal clad dpmcb, plug, socket box, in flush / surface manner as per site condition and 20 amp dpmcb, 20 amp metal clad top. 24 24 ups power dpmcb in ms enclosure supply, installation, testing and commissioning of approved make 16 amp dpmcb and required size metal enclosure in flush / surface manner as per site condition 25 25 telephone point supply, installation, testing and commissioning of approved make 2 pair 0.5 mm dia copper conductor pvc insulated and sheathed urarmoured telephone cable from mdf to each cabin 26 26 network point supply, installation, testing and commissioning of approved make utp cat 6 cable from network switch to io point of each cabin 27 27 call bell point supply, installation, testing and commissioning of approved make and model plastic white plate 28 28 telephone mdf supply, installation, testing and commissioning of 100 pair powder coated mdf with 10 nos 10 pair krone module, stainless steel krone module stand in flushed manner with required mortar etc 29 29 carefully removing of all mcbdbs carefully removing of all mcbdbs, cables, wires, telephone mdfs, if any on the floor as directed by bank?s engineer and as per site conditions....

Directorate Of Municipal Administration - Maharashtra

37745599 matheran electrical material supply , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning 11kv hrc fuse 10a to 40a for load break switch with necessary nut bolts complete. , supplying, installing, testing and commissioning 11 kv hrc fuse 63a for load break switch with necessary nut bolts complete. , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap ac/wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7tr to 0.9tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning ip epabx for 10 extensions complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 6 x 16 extension complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 3 x 8 extensions complete. , supplying, installing, testing & commissioning analogue type epabx of 3 x 8 extension complete. , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 2280 to 2850lpm at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 45kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 1600 to 1800 lpm at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 30kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning 3 phase, 22/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°c at ambient temp max 50°c & min 5°c at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage & frequency (+15% is tol) 1.80 kw, full load loss at rated current 3.00 kw, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 23 degree of protection, cable box arrangement at hv side & bus duct at lv side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & wti scanner with 3 pt 100 sensors, etc. standard accessories complete with test certificate (as per is:11171 & iec 60076 11) with necessary permissions of electrical inspector, as per specification no. ss tr. , supplying, installation, testing and commissioning 3 phase, 11/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oc at ambient temp max 50oc and min 50oc at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage and frequency (+15% is toi) 1 kw, full load loss at rated current 3.15 kw, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 21 degree of protection, cable box arrangement at hv side and bus duct at lv side, with rating and diagram plate, base channel, earthing terminals and wti scanner with 3 pt 100 sensors, etc., standard accessories complete with test certificates (as per is:11171 & is 2026) with necessary permissions of electrical inspector as per specification no. ss tr. , supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results specification no. ea mobi , supplying, fixing, and configuring modularised multi service router 802.11/a/n/ac unified wave 2.5 ghz, with rj 45 port, supporting 1 to 13 channels for 2.4 ghz, with unified wireless access point complete , supplying, fixing, and configuring 24 ports with 4 (sfp+) port, ethernet managed switch with web view/cli, 6kv surge protection on ethernet port and console port for management in provided rack as per specification no. wgnwc/gbs , supplying, fixing, and configuring 24 ports + 4 (sfp+) port, managed layer 2, poe switch of , 370w, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing, and configuring 20 sfp ports + 4 combo sfp 10/100/1000 base t erected in provided rack complete. , supplying, fixing, and configuring 20 (1g rj45) ports + 4 combo 1g ports + 4 10g (sfp+) ports, layer 3 switch, si image, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr / mcbcos , supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of ....... hrs. pwm & igbt based, with 0.8 to unity output pf complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 82.5 kva up to 100 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 62.5 kva up to 82.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 50 kva up to 62.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 40 kva up to 50 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 35 kva up to 40 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 25 kva up to 35 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 20 kva up to 25 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 15 kva up to 20 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 125 kva up to 140 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 100 kva up to 125 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 10 kva up to 15 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of diesel generating set with standard control panel with alternator of 5 kva continuous rating, single phase, 230v, 50c/s 0.8 p. f. ac supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self excited, selfregulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 1.3 ltr/hr @75% loading. engine and alternator directly coupled on a common fabricated steel base plate with anti vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. the complete set enclosed in acoustic enclosure made of 18 swg crca sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 db at 1.0 m. the engine with first filling of oil, diesel not less than 13 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 14.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 145 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 11.3 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 9.98 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 7.47 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.9 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 34.40 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db(a) at 1.0 m, provided with first filling of oil, diesel not less than 300 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.8 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 50 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 17.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 2.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of 6kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 3kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 28hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 20hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56°c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 12hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 6a to 32a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & commissioning mdf box 600x600 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 500x500 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 400x400 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 300x300 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 250x250 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 200x200 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 150x150 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 100x100 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 100a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying table fan of a.c. 230 v. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and hand shield type 3 pin plug top. , supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying led concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4w 6w led including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. , supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 star inverter type, stabilizer free operation suitable for operation on 100v/300 v, 50hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. , supplying and plugging 3 m fibre patch cord lc sc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc sc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and laying rigid steel conduit 16 swg 32 mm dia. with necessary accessories in rcc work/false ceiling/false flooring as per specification no: wgma/cc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and installing, testing & commissioning of digital (hybrid) type epabx of 6 x 32 extensions suitable upto 96 extensions complete. , supplying and fixing wireless n 150 desktop adapter in provided computer as per specification no. wg nas/lanc2 , supplying and erecting vpit heavy duty copper wound ballast 230v for 80 150w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting vpit compound heavy duty copper wound ballast for 230v for 250w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system. , supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) , supplying and erecting two pole power contactor 230 v, 32 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole metal clad changeover switch 240 v, 32 a erected on angle iron/gi frame and duly connected with suitable wire leads complete , supplying and erecting triple pole mini feeder pillar with 500v, 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a with aluminium bus bar erected in 14 swg crca sheet box with supporting angles, self locks, gasket having ip54,ik10 protection and slanting top to be erected on provided foundation complete as per specification no. sw , supplying and erecting t8 fluorescent tube day light 1200mm, 36 w , supplying and erecting t5 24 w energy efficient fluorescent tube. , supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt/bpc , supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.ap wh/stwh , supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kwh / 24 hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 2 ways (2 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 10 ways (10 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting shockproof t. switch 16 a porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof piano type switch 250 v, 16 a, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (trs type) pvc insulated copper wire of size 0.5 sq mm 5 m length connected to the point. , supplying and erecting shockproof 6a porcelain base t.switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected , supplying and erecting shockproof 3 pin plug socket 6a with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof 3 pin plug socket 16a with porcelain base/ flush type erected on filled polypropylene (is:14772 2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting rectangular shaped led panel light(1200mm x 300mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6a erected on m.s box made of 16 swg sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6 a combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor. , supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con , supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected , supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 1 module complete duly erected. , supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. , supplying and erecting pvc surface modular double mounting plate 8 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 6 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 4 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 3 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 2 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 16/18 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 12 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 1 module complete duly erected. , supplying and erecting pvc slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. , supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box . , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. , supplying and erecting porcelain base iron clad cut out hc type 415v, 63a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 32a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 200a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 16a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 100a erected on polished wooden block. , supplying and erecting pole clamp made from 50x6mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting pole clamp made from 50x10mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 63a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, , ip 54 and ik10 protection, 45 a tp contactor for automatic switching of luminaires, 2 no 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 32a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, ip 54 and ik10 protection, 25 a tp contactor for automatic switching of luminaires, 2 no. 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting one/two way piano type switch 6a./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting modular type two way switch 6a / 10a (2 module), duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch one way 16 / 20 a, duly erected on provided plate and box with wiring connections complete with neon indicator. , supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch 16a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type buzzer 220 / 250v, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type blanking plate two module, duly erected on provided plate & box , supplying and erecting modular type bell push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell push 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 6 / 16a fuse unit, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections , supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 600/650w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 1000w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (one module) electronic dimmer 400 / 450w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete , supplying and erecting metal halide lamp double ended 230v, 70 w . , supplying and erecting metal halide lamp double ended 230v, 250 w. , supplying and erecting metal halide lamp double ended 230v, 150 w . , supplying and erecting marine (waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to is 720:2010 , supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with 4x25 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 2x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230v a.c. supply with resetting arrangement complete erected on double wooden/ sunmica board. , supplying and erecting lszh armoured multimode optical fibre cable with 6 fibres, core dia 50/125 ?m (om4) suitable up to 10 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. wg coc/ofc , supplying and erecting led strip light 5m length max. 95 w ip20 class having minimum lumens output of 1600 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50 including driver with 1 year warranty. , supplying and erecting led strip light 5m length max. 45 w ip20 class having minimum lumens output of 800 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50, including driver with 1 year warranty. , supplying and erecting led square / circular max. 7w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led square / circular max. 25 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 18 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led panel light(600mm x 600mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg , supplying and erecting integrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf/fls2. , supplying and erecting integrated led street light fitting 120w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led post top 45w ip65 & ik10 class having die cast aluminium housing with uv protected polycarbonate diffuser, having system lumens output of min.4500 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 30,000 hrs. at l50b50 , including driver complete with 2 year warranty as per specification no fgodf/fls , supplying and erecting integrated led highbay fitting 135w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50,000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 70w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 8400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 5000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 30w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 3000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 195w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 23400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 155w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 18600 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 120w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min.14500 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 800mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 500mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting ignitor suitable for 230v hpsv lamp 70/150/250/400w as specification no. fg fg/as6 , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 70 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head / pin type 230v, 70 w son type. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma/con. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall /ceiling as per specification no: wg ma/con. , supplying and erecting gi wire of high purity of required sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete. , supplying and erecting gi strip of high purity required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint with joints required. as per specification no ea ep. , supplying and erecting gi sheet 0.8 mm (22 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gi sheet 0.6 mm (24 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12w led lamp on provided pipe as per specification no. fg , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, g.l. stay wire 7/8 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop insulator, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable ms clamps duly erected in provided c.c. foundations complete. , supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting g.i. pipe ‘c’ class erw 75/80 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15m long) with pole clamp, made of 50x6mm ms flat, erected on provided rsj pole complete. (add. rs. 25/ per m for extra length beyond 15 m) , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for, 1kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top suitable for with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 4kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting four pole power contactor 430 v, 16 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting flush, shock proof plug socket 6 pin 6a and 16a with switch 16a combined unit erected in recess in 16 gauge m.s sheet box duly painted and connected with earth terminal and leads , supplying and erecting flush type, shockproof plug socket 6 pin 6a and 16a with switch 16a combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with s m screws and duly connected. , supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. , supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. , supplying and erecting exhaust fan heavy duty 230 v, a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 1400 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg , supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn/cf , supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of 28w having service ratio (cmm/w) of min. 8 , pf>0.9, thd , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 76w100w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th , supplying and erecting electronic type driver for outdoor led fittings 46w75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<1 , supplying and erecting electronic type driver for outdoor led fittings 26w45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and , supplying and erecting electronic type driver for outdoor led fittings 151w200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 101w150w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd , supplying and erecting electronic ignitor suitable for 230v metal halide lamp 70/150/250/400w (integral or non integral type luminaires as specification no. fg fg/as6 , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. , supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. as per specification no. eaep. , supplying and erecting control gear for non integral flood light fittings suitable for 2x250w hpsv/mh lamp with all accessories complete. , supplying and erecting control gear for non integral flood light fittings suitable for 1x400w hpsv/mh lamp with all accessories complete. , supplying and erecting condenser for mv/sv/mh lamp 250w,230v as specification no. fg fg/as7 , supplying and erecting condenser for mv/sv/mh lamp 150w,230v as per specification no. fg fg/as7 , supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting c type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting c type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. , supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no ea ep. , supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles a.c. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting acrylic sheet 3 mm thick to be used for covering the crca sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete. , supplying and erecting 75 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 50 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 40 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 30 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 570 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries) , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries , supplying and erecting 12v/80ah to 88ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/7ah 7.5ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/42ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/26ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/17ah 18ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/130ah to 135ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. , supplying and erecting 12.5 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/hm (excluding luminaries , supplying and erecting 12 v/65ah smf battery with battery terminal wire, duly charged complete with 24 months warranty complete , supplying and erecting 11 kv outdoor type gang operated air break, triple pole switch 200 a capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of c class g.l. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground level with necessary clamp. , supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 100 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting ‘d’ type pole clamps, fabricated from 50x6mm ms flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12 exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12 exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(e), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating 11 kv(e), 3 x 70 sq. mm., aluminium conductor xlpe insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. cb ht , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300 x 200 x 150 mm complete on pole as per specification no. cb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 150 x 100 x 100 mm complete on pole as per specification no. cb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 , supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting three phase, 415v, street light control panel up to the max load of 12kw, tpn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 4 pole contactor up to 60a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 2 pole contactor up to 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting single pole cut point channel set of for 11kv ht oh line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. , supplying & erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ cc foundation. , supplying & erecting single phase, 240v, street light control panel up to the max load of 12kw, spn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting single compression type brass cable glands for 4 core 35 sq.mm./3 core 50 sq.mm. for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying & erecting ms pole bracket for lt oh conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 2.25 kw/3 hp with discharge 600/110 litres per minute (lpm) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 1.5 kw/2 hp with discharge 600/140 litres per minute (lpm) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 5.625 kw/7.5 hp with discharge of 780/170 litres per minute (lpm) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 3.75 kw/5 hp with discharge 715/200 litres per minute (lpm) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 230v, single phase 50 cycles a.c. supply of 1.125 kw/1.5hp with discharge 198/50 litres per minute (lpm)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (light house type) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (globe type) suitable for led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. fg , supplying & erecting inline d.p. structure for 11/0.415kv, 63kva transformer with rsj pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of crca sheet 16 swg with 4 pole mccb 100a as incomer & 6 nos. 63a kitkat/mccb for outing circuits. transformer d.p. structure includes the a.b. switch 200a, d.o. fuse set & l.a. set. 2 nos. top channel of size 100x50mm for erection of a.b. switch & 2 nos. base channel of size 100x50mm for erecting transformer channel of size 75x40mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 200 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 300 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete , supplying & erecting g.i. pipe ‘a’ class 75 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting fully automatic star/delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. , supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting four pole on load change over switch, 415v, 63a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 40a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 32a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3 . , supplying & erecting four pole on load change over switch, 415v, 315 320a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 200a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 160a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 100a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 10 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 h.p. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 h.p. , supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 h.p. , supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification no. cb cl/al , supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 30 a, 3 pin plug & earth socket and 30a, 3 pin plug top with 30a triple pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron / gi frame. , supplying & erecting co axial copper cable low voltage grade tri shielded rg11 as per specification no. wg tw , supplying & erecting co axial copper cable low voltage grade tri shielded rg , supplying & erecting cast iron cable indicator plate buried along with route of cable for pvc / xlpe armoured cable as per specification no. cb cip , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 hp consisting of star delta starter having relay range 9 14 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 15 hp consisting of star delta starter having relay range 13 22 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e , supplying & erecting 14w, 230v integral type led lamp suitable for b 22 / e27 base. , supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. , supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 0.5 mm dia, copper jumper wire as per specification no. wg tw , supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. , supply and erecting 9m (clear height) fixed type high mast (top 100mm, bottom 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. oh pl/opl (excluding luminaires). , rewinding the motor of the exhaust fan 900 / 1400 rpm 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year , rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. , rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for original speed and consumption with guarantee for 1 year including transportation from site and back , rewinding of electric motor upto 1 h.p. single phase up to 1400 rpm of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year. , rewinding of electric motor up to 1 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 7.5 h.p. upto 10 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea , rewinding of electric motor above 5 h.p. upto 7.5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 3 h.p.upto 5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 2 h.p. upto 3 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 1 hp upto 2 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. , providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep , providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 kilogram). , providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as per specification no. cb jt/ht , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 400 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 300 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 200 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 150 mm width & 100 mm height comprising all required standard accessories , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 8 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no sw swr/mccbpb. (excluding mccbs) , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 12 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no. sw swr/mccbpb. (excluding mccbs) , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as per specification no. cb jt/lt , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure/panel as per specification no. sw swr/mccb , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. oh pl/opl , point wiring in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/fan/bell in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire with flush type switch and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/cw , point wiring for independent plug, concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/c , point wiring for ceiling fan (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw/hw , making trench in soft soil having 0.9m depth and minimum 0.3 m width as per is for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. external surface duly plastered by 12 mm thick including watering etc complete , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). , excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. , concealing of provided g.i. pipe/h.g. screwed conduit/pvc pipe in wall/floor/false ceiling complete as per specification no:wg pw/cw , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole)....

Directorate Of Municipal Administration - Maharashtra

37720932 supply of electric materials for light dept in shrigonda council , 2 core 2.5 sqmm aluminium wire bundle ( 90 mtr ) 2 core 4 sqmm aluminium wire bundle ( 90 mtr ) 2 core 6 sqmm aluminium wire bundle ( 90 mtr ) 4 flexible wire per mtr 1 core 1 sqmm coppr wire ( per mtr ) 1 core 1.5 sqmm coppr wire ( per mtr ) 1 core 2.5 sqmm coppr wire ( per mtr ) 3 core 1.5 sqmm copper cable ( per mtr ) 4 core 4 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 6 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 10 sqmm xlpe armoured aluminium cable ( per mtr ) 9 4 core copper cable 4 sqmm 4 core copper cable 6 sqmm 13 14 xlpe armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) xlpe armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 151 16 xlpe armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire ( per mtr ) 17 main switch 1 phase 32 a 18 main switch 1 phase 63 a 19 main switch 3 phase 32 a main switch 3 phase 63 a main switch 3 phase 100 a main switch 3 phase 200 a mcb spmcb 5a 24 24 mcb spmcb 6 32a mcb tpmcb 6a to 32a mcb tpmcb 40a to 63a 26 mcb fpmcb 6a to 32a mcb fpmcb 40a to 63a contactor 2 pole 32 a contactor 4 pole 16 a contactor 4 pole 40 a 22 32 ceramic cut out 32a 33 ceramic cut out 63a 34 ceramic cut out 100a 35 35 ceramic cut out 200a 336 insulation tape per box ( 30 piece in box ) 337 led bulb 5 w 38 led bulb 9 w 39 led bulb 15w 40 led bulb 20 w 41 angle holder 42 led tube patti 18 w 21 43 led tube patti 20 w 404 led tube patti 25 w 45 45 clamp for rail, cement pole / clamp clamp for round pole / clamp 46 clamp for highmast / clamp 47 47 bracket for rail, round, cement pole 6 module switch board 12 module switch board 18 module switch board 6*8 module switch board 2 module switch board 48 49 50 51 52 55 53 54 modular 3 pin 6 a socket modular 3 pin 16 a socket 55 56 modular 5 pin 6 a socket modular 5 pin 16 a socket 57 ཆ| 58 fan pvc regulator 59 fan step regulator 60 modular switch 6a 61 modular switch 16a 62 29 bell switch modular 16a 63 39 dp switch modular 16a 64 dp switch modular 32 a 65 bell switch modular 32a ceiling fan 1200 mm ( copper winding ) ceiling fan 900 mm ( copper winding ) wall fan 400 mm 69 standing fan 400 mm 70 fan capacitor 3.15mfd 71 fan capacitor 2.5mfdg 72 dummy plate 73 extension board 74 casing patti per mtr 75 casing pipe 0.5 inch per mtr 76 3 pin plug top 6a 77 3 pin plug top 16a supplying porcelain shackle type lt medium insulator 50 x 89 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 78 79 supplying aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) per mtr 80 supplying aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) per mtr 81 playwood board 6*4 22 82 playwood board 8*6 83 aluminium lug 6 mm 84 aluminium lug 16 mm 85 86 copper lug 6 mm copper lug 16 mm 87 male female pin 88 pvc clamp pocket 89 upto 25w led driver upto 25w led plate upto 25w led spd 26 45w led driver 92 26 45w led plate 93 26 45w led spd 55 46 75w led driver 96 46 75w led plate 97 46 75w led spd 98 office bell 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe ( per mtr ) 99 24 hrs digital / astronomical timer for street light control panel 100 changeover switch 32 a fp 101 changeover switch 63 a fp 102...

Bhiwandi Nizampur City Municipal Corporation. - Maharashtra

37657077 providing and supplying spare part for all types of borewell as per requirement in bncmc area for one year 2023 2024 1 providing and supplying spare part for all type of borewell as per requirment in bncmc area ( year 2023 2024 ) 2 item no. 1 : providing & suppling gi unionmjp elec / mech csr 2021 22 pg no. 11 pw 1 25 mm dia 3 40 mm dia 4 item no. 2 : providing & suppllying gi pipe mjp dsr 2021 22 pg no. 82 / 1 / b 25 mm dia c class 5 32 mm dia c class 6 item no. 3 : supplying g.i. coupling / nipple b class mjp elec / mech csr 2021 22 pg no. 11 pw 3 25 mm dia 7 40 mm dia 8 item no. 4 : supply & erecting & treminating pvc armouredcable 3 core 2.5 sq mm copper conducter continuous 5.48 sq mm ( 12 swg ) gi earth wire complet erected with glands & lgs on wall trusses / pole or laid in providedtrench / pipe as sper specification on cb lt / cu pwd elect mech. csr 2021 2022pg.128 7 2 14 9 item no. 5 : supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible / centrifugal pump set upto 2 hpconsisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosedin crca powder coated vibration proof encloser with ip 54protection. control panel should offer single phasing, phasereversal, phase inbalence etc ( similar to lt model no.mr g2 ) pwd ele csr2021 2022csr page no 219 / 12 4 20 10 item no. 6 : supplying, erecting & terminating pvc armoured cable 2 core 4 sq mm aluminium conductor with continuous 5.48sq mm ( 12 swg ) g.i. earth wire complete erected withglands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / alpwd ele csr2021 2022csr page no 128 / 7 2 9 11 item no. 7 : supplying and erecting submersible pumpset of required hp with 415 v, 50 c / s ac supply suitable for 150 mm dia.borewell suitable for 20 to 80 lpm discharge at 55 to 25 mhead & ( max efficiency at 41 m head & 50 ipm discharge &delivery pipe of necessary diameter with a necessary h. typeclamp as per specification no. wp smppwdele match csr 2021 2022pg no 208 12 2 1 12 item no. 8 : providing & supplying blue m.d.p.e. pipes conforming to iso4427:1996 manufactured from virginresin pe 80 food grade complunded raw materialhaving blue colour only with quality assurance cerificate from quallity agencies like wrc / cipet ( india ) dvgm / kiwa / spgn etc for usage in drinking water system thecost shall include testing fo all materials including all staturotyduties & taxes such as gsr livied by goi & gom in all respect inspection shcarges trandportaiton up to site transitinsurance loading as specified and diretcted unloading stacikg etc complet as specified and directed25mm diamjp dsr 2021 2022 pg no 118 / 1 13 item no. 9 supplying and erecting d.o.l. starter 400v. 3 phase, 50 cycles withno volt coil and overload element with necessary materials andconnected to supply upto 7.5 h.p.pwdele match csr 2021 2022 pg no 21812 4 2 14 item no. 10 supplying and erecting d.o.l. starter 400v. 3 phase, 50 cycles withno volt coil and overload element with necessary materials andconnected to supply upto 10 h.p.pwdele match csr 2021 2022 pg no 218 12 4 3 15 item no. 11providing and fixing following mm diascrewdown bib / stop tap of brass including necessary socketuni on nut complete. pwdssr 2022 2023 pg no 22541.40, 41.42 15 mm dia 16 25 mm dia 17 item no. 12 : providing hand pump cylinder 18 item no. 13 : providing hand pump gi stand assembly 19 item no. 14 : providingwater tank assembly 20 item no. 15: providinggi head assembly 21 item no. 16 : providing gun matel upper valve assembly 22 item no. 17 : providing gun matel lower valve assembly 23 item no. 18 : providing stainless steel plunger rod 24 item no. 19 : providing reducer cap 25 item no. 20 : providing gun matel plunger yoke body 26 item no. 21 : providing upper valve rubber seating ( nitrial rubber ) 27 item no. 22 : providingsealing ring ( nitrial rubber ) 28 item no. 23 : providingpump bucket ( leather ) 29 item no. 24 : providinggunmatel follower ( leather ) 30 item no. 25 : providinggunmatel check valve guide 31 item no. 26 : providinggunmatel check valve seat 32 item no. 27 : providingcylinder body liner ( gunmatel ) for india mark ii 33 item no. 28 : providinggalvanised handle bar 34 item no. 29 : providingstainless steel handle axle 35 item no. 30 : providingskf bearing 6204z 36 item no. 31 : providingrollar chain ( diamond make ) 37 item no. 32 : providinghexagonal bolt galvanized size 12 x 1.75 x 40 mm 38 item no. 33 : providinghexagonal nut galvanized size 12 x 1.75 39 item no. 34 : providinggi washer m 12 4 mm thickness 40 item no. 35: providing hexagonal rod coupling m x 12 x 15 mm ( galvanised ) 41 item no.36: providingconnecting rod 12 mm dia 3 meter length made of bright bar elcetro galvanised fitted with coupler item no. 37 : providinghead for india mark ii 42 item no. 38 : providinggrese ( 2 kg pack ) ...

Directorate Of Municipal Administration - Maharashtra

37548901 annual work for supplying of electrical material for year 2023 24 1 items 2 supplying of electrical material to municipal council, buldana 3 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housing complete. 4 supplying and erecting square / round shaped crca / die cast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13 to18w with provision for plane front frame with translucent cover fixed to the housing complete. 5 supplying and erecting t 5 led tube light complete. 6 supplying pvc armoured cable 4 core 16 sq mm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 7 supplying pvc armoured cable 3 ½core 35sqmm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 8 supplying mains with isi mark wp 2×2.5 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 9 supplying mains with isi mark 1 sq.mm. aluminium pvc insululated wire. 10 supplying mains with isi mark wp2×4 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 11 supplying 3 phase 100 amp with isi mark contactor 12 supplying and erecting quartz electronic time switch having 24 hour dial to work on 250v 50cycle a.c. 13 supplying & erecting approved make 500v 100a porcelain base neutral link complete erected in provided m.s. box with hrc fuse cartridge 500v 100a 14 supplyingcabin fan of a.c. 230 v. 50 cycles 400 mm.sweep complete with necessary brackets for fixing cabin fans, wire etc. 15 supplying regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position. 16 generator servicing and repairing for 25 kva generator. 17 supplying and erecting 12 v / 100ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 18 supplying and erecting split type room airconditioning unit 1 tr 5 star capacity 250v, 50 cycles, a.c. supply having 1 no of air handling unit hi wall / floor mounting type complete at position. 19 suppyling and erecting mcb rating 40 63 amp 20 supplying and erecting isolator rating 40 63 amp 21 supplying and erecting street light panel with contactor , timer , mcb isolator complete ( rating 100 amp ) ...

Directorate Of Sports And Youth Affairs - Maharashtra

37300893 proposed preparation of basketball court at district sports complex latur , work portion ( a ) , excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. ( lift upto 1.5 m. ) by mechanical means , filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. , supplying hard murum / kankar at the road site, including conveying and stacking complete. , supplying soft murum at the road site, including conveying and stacking complete. , providing dry / trap / granite / quartzite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. , providing and laying cast in situ / ready mix cement concrete in m20 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, steel centering, formwork, laying / pumping , compacting, roughening them if special finish is to be provided, finishing uneven and honey combed surface and curing etc. complete. the cement mortar 1:3 plaster is considered for rendering uneven and honey combed surface only. newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. ( wooden centeringwillnotbeallowed. ) , withfullyautomaticmicroprocessorbasedplcwithscadaenabledreversibledrumtypemixer / concretebatch mix plant ( pan mixer ) etc. complete. with fine aggregate ( crushed sand vsi grade ) , providing and fixing in position tmt fe 500 bar reinforcement of various diameters for r.c.c. pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. , providing and laying concrete pipes of i.s.np. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. , providing and laying concrete pipes of i.s.np. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. , providing and constructing brick masonry inspection chamber 90cm x 45cm with r.c.c. raft in b.c. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round g.s.w. pipes, brick masonry, plastering from inside and airtight with 75 mm thick r.c.c. cover medium duty 140 kg etc. complete. , providing and laying in walls / ceilings / floors 20 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 1.63 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and laying in walls / ceilings / floors 25 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 2.49 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and laying in walls / ceilings / floors 32 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 3.20 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and fixing c.p. two way bib cock of approved make continental including necessary sockets / union nut etc. complete. , open graded premix surfacing providing and laying ogc 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with vts , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and seal coat. for bitumen of specified grade using drum mix type hot mix plant with scada, paver and vibratory roller ( over mpm surface ) ( vg 30 bulk bitumen rates are considered to arrive at rates ) , providing bituminous type a liquid seal coat on bituminous surface including supplying all materials and bitumen of specified gradepreparing existing road surface, heating and applying bitumen @ 0.98 kgsqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 mt. etc. complete. ( vg 30 bulk bitumen rates are considered to arrive at rates ) , providing and fixing synthetic and tennis court on black toping surface, before applying synthetic. cleaning the existing surface by water and then apply entire area with one coat of primer and punding and coacked surface are afillingn with binder and then apply resurfaces black and then apply three coat of synthetic, game line marking a fixing tennis pole and net and as directed by engineer incharge rate are including of all taxes and transportation of material to work slope. ( rate sanctioned by s.e vide letter no. osm / pwc / bldg / 4243 dated 29 / 06 / 2016 ) , providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. , providing and fixing crimped with g.i. mesh and size 20 mm x 20 mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel ) , providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per is 4923 yst310 grade produced from iron ore and blast furnacer out etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. , testing charges ( b ) , charges for testing if material in vigilance & quality control laboratory for cement ( standard consistancy fineness, specific gravity, setting time ( initial & final ) compressive strngth, soundness ) , electrical charges ( c ) , supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fgodf / fls 2 , ( cable 4x10 sq.mm. ( 7.2.33 ) supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cblt / cu , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt / bpc , mains 1x2.5 sq.mm. ( 1.3.3 ) supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw , mcb tp 40 a to 63 a ( 5.3.15 ) supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. sw swr / mcb , tpndb ( 5.4.1 ) supplying and erecting triple pole and neutral distribution board ( tpndb ) surface / flush mounted suitable for spmcb of 12 ways on iron / gi frame ( horizontal busbar type ) as per specification no. sw swr / mcbdb , pipe type earthing ( 9.1.4 ) providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , trench ( 16.1.2 ) making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exn ctr , earth plate ( 9.1.3 ) providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. eaep , g.i. pipe ( 7.6.2 ) supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce , add 5% contingencies , add 2% consultant fees , add 18% gst , add 0.1% labour insurance...

Ulhasnagar Municipal Corporation - Maharashtra

37300021 e tender for providing mini highmast in electrical bus transport depo, plot no 1606 to 1620 nr. sai legend world nr. shahad station, ulhasnagar 1 e tender for providing mini highmast in electrical bus transport depo, plot no 1606 to 1620 nr. sai legend world nr. shahad station, ulhasnagar 1 , supplying and erecting led flood light fitting of 200w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminum alloy and heat sink extruded aluminum complete make: polycab / bajaj / wipro ( sample approved in umc ) , providing & erecting 9 m high galvanised conical pole with foundation bolts having bottom dia. from 165 to 200 mm, top dia. from 65 to 75 mm on provided foundation make: bajaj / faryas / volmount / transrail , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) make as per pwd guideline , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the resultsmake: as per ie standard , making the trenchin hard murum / tar road suitable for width and depth for laying cablesmake : as per ie standard specification , making trench of suitable width and depth in hard murum / tar road for laying providedof lt cables of16 sq mm and above and covered with half round hume pipe completed make as per pwd guideline , supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 75 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete make as per pwd guideline , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv make: polycab / pressfit / vishal / finolex , supplying, erecting & terminating xple armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with make: polycab / pressfit / vishal / finolex , supply and erectingroad light box panel manufactured g.i sheet 1.25 ( 18 guage ) box size 30x24x12 deep with wooden planks etc. with road light box clamps for mounting of road lights on msedcl pole with 100 amp , 3 phase tpn main switch and 60 amp porcelain connector with complete wiringmake as per umc approved , supply and erectingtimerbox panel manufactured g.i sheet 1.25 ( 18 guage ) box size 21x19.5x7 deep with wooden planks etc. with 40 amp power contactor 3 nos 63 amp mcb 3 nos almanac digital timer 01 , 60 amp porcelain connector 03 nos etcwith complete wiringmake as per umc approved...

Directorate Of Municipal Administration - Maharashtra

37221150 tender for supply of electric materials for light dept in shrigonda council 2 core 2.5 sqmm aluminium wire bundle ( 90 mtr ) 2 core 4 sqmm aluminium wire bundle ( 90 mtr ) 2 core 6 sqmm aluminium wire bundle ( 90 mtr ) 4 flexible wire per mtr 1 core 1 sqmm coppr wire ( per mtr ) 1 core 1.5 sqmm coppr wire ( per mtr ) 5 6 1 core 2.5 sqmm coppr wire ( per mtr ) 7 3 core 1.5 sqmm copper cable ( per mtr ) 4 core 4 sqmm xlpe armoured aluminium cable ( per mtr ) 8 9 4 core 6 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 10 sqmm xlpe armoured aluminium cable ( per mtr ) 10 11 12 xlpe armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 13 xlpe armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 14 xlpe armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire ( per mtr ) 15 mainswitch 1 phase 32 a 16 mainswitch 1 phase 63 a 17 mainswitch 3 phase 32 a 18 mainswitch 3 phase 63 a 19 mainswitch 3 phase 100 a 20 20 mainswitch 3 phase 200 a 21 mcb spmcb 5a mcb spmcb 6 32a 22 23 mcb tpmcb 6a to 32a 24 mcb tpmcb 40a to 63a mcb fpmcb 6a to 32a 25 mcb fpmcb 40a to 63a 26 contactor 2 pole 32 a 227 contactor 4 pole 16 a 28 contactor 4 pole 40 a ceramic cut out 32a ceramic cut out 63a ceramic cut out 100a ceramic cut out 200a insulation tape per box ( 30 piece in box ) led bulb 5 w 36 led bulb 9 w 317 led bulb 15w 38 88 led bulb 20 w 39 angle holder 40 led tube patti 18 w 41 led tube patti 20 w 42 led tube patti 25 w clamp for rail, cement pole / clani clamp for round pole / clamp. clamp for highmast / clamp bracket for rail round, cement pole 46 6 module switch board 47 12 module switch board 48 18 module switch board 49 6*8 module switch board 50 2 module switch board 51 modular 3 pin 6 a socket 52 modular 3 pin 16 a socket 53 modular 5 pin 6 a socket 54 modular 5 pin 16 a socket 55 56 fan pvc regulator 58 fan step regulator 59 modular switch 6a 60 modular switch 16a 61 bell switch modular 16a 62 dp switch modular 16a 63 dp switch modular 32 a 64 bell switch modular 32a ceiling fan 1200 mm ( copper winding ) 65 ceiling fan 900 mm ( copper winding ) 67 wall fan 400 mm 68 69 standing fan 400 mm fan capacitor 3.15mfd 70 fan capacitor 2.5mfdg 71 dummy plate 72 extension board 73 casing patti per mtr 74 casing pipe 0.5 inch per mtr 75 3 pin plug top 6a 76 3 pin plug top 6a 77 supplying porcelain shackle type lt medium insulator 50 x 89 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 78 supplying aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) per mtr 79 supplying aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) per mtr 80 playwood board 6*4 81 playwood board 8*6 82 aluminium lug 6 mm aluminium lug 16 mm 83 84 copper lug 6 mm 85 copper lug 16 mm 86 male female pin 87 pvc clamp pocket 88 upto 25w led driver 89 upto 25w led plate 90 upto 25w led spd 91 26 45w led driver 92 26 45w led plate 93 26 45w led spd 94 46 75w led driver 95 46 75w led plate 96 96 46 75w led spd 97 office bell 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe ( per mtr ) 98 99 24 hrs digital / astronomical timer for street light control panel...

Reserve Bank Of India - Maharashtra

37200165 dismantling carefully removing all distribution boards, fans, light fittings, decorative lights, geysers, water purifier, wires, conduits, casing capping switch boards, telephone sets etc. provided in the flat and keeping reusable items in safe place as instructed / directed by bank?s engineer. 2 2 sitc of mcb db supply, installation testing and commissioning of single phase 12 way mcb d.b. metallic double door ( factory fabricated ) , in concealed manner of approved make, all termination of wires with lugs with crimping etc incomer 40 amp dp rccb ( 30 ma ) 1 no. outgoing 20 amp sp mcb 5 no. 10 amp sp mcb 5 no. blank plates as required, mcbs with 10 ka breaking capacity & c curves, with all accessories and interconnections as instructed by bank?s engineer. 3 3 wiring for light point supply, laying, installation, testing & commissioning wiring for light points using three runs of 1.5 sq mm, 1100 volt grade fire resistant low smoke ( frls ) pvc insulated stranded copper conductor wire ( neutral, and earth in looping system ) to respective point outlet ( inclusive of circuit wiring using three runs of 2.5 sq mm 1100 volts grade stranded copper conductor pvc insulated fire resistant low smoke frls wire from mcb db to respective switchboard ) partly in surface with heavy duty required size of casing , capping for ceiling , beam points & partly in rigid heavy duty pvc conduit of required size with all accessories, to be laid in concealed manner after a chase made in wall including mending good the damages as original finish manner with all accessories like coupler, bend, long bend, tee, junction box, required hardware materials etc as directed, .. for complete details refer tender document. 4 4 wiring for ceiling fan point same as item no. 03 above, but for ceiling fan point along with supply and fixing of electronic 5 step 120 w type fan regulators as approved by banks engineer, socket type with speed marks, modular type of approved make with 10 amp modular switch as specified in item no 03 and complete with interconnection etc 5 5 wiring for 10 amp plug point independent wiring for independent 10 amps plug point with 3 x 2.5 sq mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no.03 above, along with 10 amp modular switch, and shutter type socket ( 2 pin+ 3 pin ) mounted separately on suitable size heavy duty gi box for concealed. these 10 amps points are to be extended from main switch boards provided in respective room as directed by banks engineer 6 6 wiring for half point on control switch board same as item no. 03 above, but for supply, fixing providing ( half point ) wiring for 10 amp. universal socket ( 2 pin + 3 pin ) and switch modular type to be fixed on same switch board used for light / fan / plug point. 7 7 wiring for computer point same as item no.03 with 3x2.5 sq.mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner but for computer point consisting of 3 no.s 10a 3 / 5 pin socket controlled by 3 no 10a modular switch fixed with suitable size heavy duty gi box for concealed with pvc board for surface as specified in item no.03 above. a separate conduit to be taken from mcb db with separate earth wire. 8 8 wiring for call bell point wiring for bell point as per item no 03 above, but with 10 amp modular bell push to be fixed in concealed manner with control off switch on switchboard provided in the flat along with supply and fixing of ding dong bell of approved make with hardware materials, as approved by banks engineer. 9 9 wiring for 2 switch 2 socket point for tv same as item no.5 above but for 10 amps 3 pin modular sockets 2 nos. controlled by 10 amps modular switches 2 nos. 10 10 wiring for 20 amp plug point ? independent wiring for independent 20 amps plug point with 2.5 sq. mm x 3 runs multi stranded copper conductor frls wire ( from mcbdb to plug point ) for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no 03 above, along with 20 amp modular switch, and shutter type 10 / 20 socket mounted separately on suitable size heavy duty gi box concealed with pvc board on surface along with covers of approved. 11 11 telephone wiring wiring for 03 nos. telephone sockets rj 11 outlet with shutter as per item no. 03 using two pair 0.5 mm dia tinned copper pvc insulated wire from common point in staircase to drawing cum dining room of individual flat and further looping to another point ( each bedroom ) , separate conduit to be laid for tel / cable tv wires, using all accessories as per item no. 03 ( separate conduit is to be laid up to common point in staircase ) as directed by bank?s engineer rate includes supply, laying, terminating etc. of telephone socket and wire, complete in all respect. ? drawing room: 01 nos. socket ? bedroom 1: 01 nos socket ? bedroom 2: 01 nos socket 12 12 cable tv wiring wiring for cable tv point with rj6 cable tv wire laying from cable tv operator junction box installed in the staircase up to first point in the drawing room making the parallel connection in the bed room gi with same wire rj6 cable tv wire along with modular type tv socket all in concealed manner ? drawing room: 01 nos. ? bedroom 1: 01 nos ? bedroom 2: 01 nos 13 13 ceiling fans supply, installation, testing and commissioning of 1200 mm, 3 blade new ceiling fan with all necessary mounting accessories. hall bedroom 1, bedroom 2 14 14 ceiling fans supply, installation, testing and commissioning of 600 mm, 4 blade new ceiling fan with all necessary mounting accessories. kitchen 15 15 tube light fittings supply, installation, testing and commissioning of tube light fixtures 20 / 22 w led tube light using 2 core flexible 0.5 sq mm. flat pvc insulated white copper wire with adaptor complete with all accessories, to be mounted on pvc square block as per instructions of bank?s engineer. 16 16 exhaust fan supply, fixing , testing & installation of approved make? 250 mm dia high speed exhaust fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in kitchen as per site condition complete in all respect. kitchen 17 17 exhaust fan supply, fixing , testing & installation of orient / crompton make? 200 mm dia high speed fresh air fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in wc as per site condition complete in all respect. toilet and bathroom 18 18 rebate item rebate for taking away all unusable items like wires / switches / switchboards / db?s removed under item no 01 ( per flat ) 19 19 cgst cgst amount per flat 20 20 sgst sgst amount per flat...

Tata Memorial Centre - Maharashtra

37174900 item rate running contract for annual electrical works and supply of electrical items for the year 2023 24 at actrec 1 point wiring 1.1 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.2 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.3 primary point wiring as 1.1 , modular 2 module fan regulator 250w 1.4 sitc wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvcinsulated copper conductor single core cable etc. as required. 1.5 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.6 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.7 primary point wiring as per 1.5 modular 2 module fan regulator 250w 1.8 sitc of wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5sq.mm frls pvc insulated copper conductor single core cableetc. as required. 2.1 fan hookfabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only supply ) 2.2 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only labour ) 2.3 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( composite ) 2.4 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only supply ) 2.5 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only labour ) 2.6 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners complete in all respects. ( composite ) 2.7 supply of fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( only supply ) 2.8 fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18 inch long etc. complete in all respect. ( only labour ) 2.9 supply & fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( composite ) 3 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed steel conduit as required. 3.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 3.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 3.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 3.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 3.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 3.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 3.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 4 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. 4.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 4.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 4.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 4.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 4.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 4.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 4.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 4.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 4.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 4.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 4.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 6.1 supply & fixing of casing capping of following suitable size with screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. complete as per instructions of eic. 6.1.1 half inch ( only supply ) 6.1.2 half inch ( only labour ) 6.1.3 half inch ( composite ) 6.1.4 threefouth inch ( only supply ) 6.1.5 threefouth inch ( only labour ) 6.1.6 threefouth inch ( composite ) 6.1.7 1inch ( only supply ) 6.1.8 1inch ( only labour ) 6.1.9 1inch ( composite ) 6.1.10 1.25inch ( only supply ) 6.1.11 1.25inch ( only labour ) 6.1.12 1.25inch ( composite ) 6.1.13 1.50inch ( only supply ) 6.1.14 1.50inch ( only labour ) 6.1.15 1.50inch ( composite ) 6.1.16 2.0 inch ( only supply ) 6.1.17 2.0 inch ( only labour ) 6.1.18 2.0 inch ( composite ) 7.1 fixing of pvc conduit / truncking. supply & fixing of pvc rigid conduit of following suitable size with spacers & saddles screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. compete as per instruction of eic. 7.1.1 12.5 mm ( only supply ) 7.1.2 12.5 mm ( only labour ) 7.1.3 12.5 mm ( composite ) 7.1.4 20 mm ( only supply ) 7.1.5 20 mm ( only labour ) 7.1.6 20 mm ( composite ) 7.1.7 25 mm ( only supply ) 7.1.8 25 mm ( only labour ) 7.1.9 25 mm ( composite ) 7.1.10 32 mm ( only supply ) 7.1.11 32 mm ( only labour ) 7.1.12 32 mm ( composite ) 7.1.13 40 mm ( only supply ) 7.1.14 40 mm ( only labour ) 7.1.15 40 mm ( composite ) 7.1.16 50 mm ( only supply ) 7.1.17 50 mm ( only labour ) 7.1.18 50 mm ( composite ) 7.2 providing & fixing pvc trucking of following sizes along with all accessories complete in all respect, all as directed by o i c, es. 7.2.1 50 x 50 x 2 mm ( only supply ) 7.2.2 50 x 50 x 2 mm ( only labour ) 7.2.3 50 x 50 x 2 mm ( composite ) 7.2.4 100 x 50 x 2 mm ( only supply ) 7.2.5 100 x 50 x 2 mm ( only labour ) 7.2.6 100 x 50 x 2 mm ( composite ) 8.1 laying of bunch of wires. supplying & pulling wires with 1.5 sq. mm solid / stranded copper insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.1.1 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.2 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.3 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.4 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.5 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.6 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.7 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.8 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.9 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.10 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.11 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.12 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.13 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.14 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.15 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2 supplying & pulling wires with 2.5 sq. mm solid / stranded copper pvc insulated wire with kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.2.1 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.2.2 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.2.3 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2.4 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.5 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.6 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.7 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.8 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.9 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.10 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.11 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.12 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.13 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.14 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.15 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.3 supplying & pulling wires with 4 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.3.1 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.2 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.3 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.4 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.5 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.6 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.7 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.8 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.9 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.10 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.11 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.12 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.13 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.14 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.15 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4 supplying & pulling wires with 6 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.4.1 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.2 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.3 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.4 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.5 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.6 same as item no 8.4 but for 3x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.7 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.8 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.9 same as item no 8.4 but for 4x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.10 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.11 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.12 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.13 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.14 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.15 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 9.1 concealing of pipe supplying & laying isi mark ms pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.1.1 same as item no 9.1 but for 20 mm size ( only supply ) 9.1.2 same as item no 9.1 but for 20 mm size ( only labour ) 9.1.3 same as item no 9.1 but for 20 mm size ( composite ) 9.1.4 same as item no 9.1 but for 25 mm size ( only supply ) 9.1.5 same as item no 9.1 but for 25 mm size ( only labour ) 9.1.6 same as item no 9.1 but for 25 mm sizee ( composite ) 9.1.7 same as item no 9.1 but for 32 mm size ( only supply ) 9.1.8 same as item no 9.1 but for 32 mm size ( only labour ) 9.1.9 same as item no 9.1 but for 32 mm sizee ( composite ) 9.2 supplying & laying isi mark gi pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.2.1 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only supply ) 9.2.2 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only labour ) 9.2.3 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( composite ) 9.2.4 same as item no 9.2, 25 mm dia gi same as above ( only supply ) 9.2.5 same as item no 9.2, 25 mm dia gisame as above ( only labour ) 9.2.6 same as item no 9.2, 25 mm dia gisame as above ( composite ) 9.2.7 same as item no 9.2, 32 mm diagi same as above ( only supply ) 9.2.8 same as item no 9.2, 32 mm diagi same as above ( only labour ) 9.2.9 same as item no 9.2, 32 mm diagi same as above ( composite ) 9.3 supplying & laying isi mark pvc rigid pipe of suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.3.1 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only supply ) 9.3.2 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only labour ) 9.3.3 same as item no 9.3 as above but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( composite ) 9.3.4 same as item no 9.3 but 25 mm dia pvc conduit ( only supply ) 9.3.5 same as item no 9.3 but 25 mm dia pvc conduit ( only labour ) 9.3.6 same as item no 9.3 but 25 mm dia pvc conduit ( composite ) 9.3.7 same as item no 9.3but 32 mm dia pvc conduit ( only supply ) 9.3.8 same as item no 9.3but 32 mm dia pvc conduit ( only labour ) 9.3.9 same as item no 9.3but 32 mm dia pvc conduit ( composite ) 9.4 in general same as item no 9.3 but as applicable for concealing the pipes in marble / granite flooring or wall, of following suitable sizes. 9.4.1 20 mm dia ( only supply ) 9.4.2 20 mm dia ( only labour ) 9.4.3 20 mm dia ( composite ) 9.4.4 25 mm dia ( only supply ) 9.4.5 25 mm dia ( only labour ) 9.4.6 25 mm dia ( composite ) 9.4.7 32 mm dia ( only supply ) 9.4.8 32 mm dia ( only labour ) 9.4.9 32 mm dia ( composite ) 9.4.10 38 mm dia ( only supply ) 9.4.11 38 mm dia ( only labour ) 9.4.12 38 mm dia ( composite ) 10.1 area lighting fittings covers supply fixing / replacement of glass / acrylic covers for various street light / flood light / area lighting or any such lighting fittings having same grade of glass / acrylic all as directed by o i c, es. agency is requested to see the sample first and adequate / suitable replacement sall be done. removed covers / parts shall be returned to actrec as it is. 10.1.1 for post top lantern ( only supply ) 10.1.2 for post top lantern ( only labour ) 10.1.3 for post top lantern ( composite ) 10.1.4 any other equivalent for item no 10.1 application but non standred lighting fixture ( only supply ) 10.1.5 any other equivalent for item no 10.1 application but non standred lighting fixture ( only labour ) 10.1.6 any other equivalent but for item no 10.1 appplication non standred lighting fixture ( composite ) 11.1 pvc flexible conduit supply & laying / replacement of pvc flexible conduit conforming to isi standards & approved make with required number of coupling, pvc bushes, check nuts etc complete all as per instruction of eic. in case of replacement, removed parts, items etc. shall be returned to actrec as it is. 11.1.1 same as above 20 mm dia same as above ( only supply ) 11.1.2 same as above 20 mm diasame as above ( only labour ) 11.1.3 same as above20 mm dia same as above ( composite ) 11.1.4 same as above 25 mm dia same as above ( only supply ) 11.1.5 same as above 25 mm dia same as above ( only labour ) 11.1.6 same as above 25 mm dia same as above ( composite ) 11.1.7 same as above 32 mm dia same as above ( only supply ) 11.1.8 same as above 32 mm dia same as above ( only labour ) 11.1.9 same as above 32 mm dia same as above ( composite ) 11.1.10 same as above 40 mm dia same as above ( only supply ) 11.1.11 same as above 40 mm dia same as above ( only labour ) 11.1.12 same as above 40 mm dia same as above ( composite ) 11.1.13 same as above 50 mm dia same as above ( only supply ) 11.1.14 same as above 50 mm dia same as above ( only labour ) 11.1.15 same as above 50 mm dia same as above ( composite ) 12.1 dismentling dismantling / removing the existing light, fan, bell, independent plug point, wiring of all types with accessories, switch boards etc to the satisfaction of in charge. all dismantled / removed / scrap material to be handed over to engg. dept as it is. ( only labour ) 12.2 dismantling the existing mains wires of all sizes, make running through pvc casing capping / pipes / ms conduits including casing capping / pvc pipes / ms pipes / gi pipes / hgdwc pipes / pvc or metal trunking etc. ( only labour ) 12.3 dismantling the cables of following sizes without damaging it with glands, cable end boxes, earthing, saddles, spacers & clamps etc & cleaning the surface area & hand over to engg. in –charge. ( only labour ) 12.3.1 1.5 sq. mm to 10 sq. mm ( only labour ) 12.3.2 16 sq. mm to 70 sq. mm ( only labour ) 12.3.3 above 70 sq. mm ( only labour ) 12.4 dismantling of distribution board / bus bar irrespective of size, capacity / ways etc complete with angle iron frame & making the site clear by refilling the holes etc. & finishing matching to background and handing over it to actrec as it is. ( only labour ) 12.5 dismantling ceiling fan, exhaust fan, wall / cabin fan / fluorescent lamp / night lamp etc. with accessories, gi down rod, frame etc & making the site clear & finishing matching to background and handing over the items to actrec as it is. ( only labour ) 12.6 dismantling existing electric geyser / storage type water heater irrespective of size, make, including brackets, grouting bolts etc refilling the holes with cement mortar & making the site clear and handing over it to actre as it is. ( only labour ) 12.7 dismantling of smoke detector / response indicator / bg / circuit isolator / ahu cut off, putting insulation on exposed ends etc and handing nover it t actrec as it is. ( only labour ) 13.1 rewinding rewinding of table / wall / pedestal / exhaust fan up to 300 mm / dip freezer / any similar application motor etc. of all types & make including overhauling, minor repairs, testing for the original speed including transportation, removal from point of fault & refiitting of the same after repairs for inclusive cost as mentioned in the following item nos. all the items removed while repairs / replacements except copper coils shall be handed over / returned to e i c as it is. ( composite ) 13.2 all general gidelines as per item no 13.1 but for rewinding of exhaust fan above sweep 300 mm. ( composite ) 13.3 all general guide lines as per item no 13.1 but for rewinding of ceiling fan motor of all makes and types including overhauling, including minor repairs, & testing at site of following sizes. all the removed / replaced parts / items shall be returned / handed over to e i c, es. 13.3.1 900 mm sweep ( composite ) 13.3.2 1200 mm sweep ( composite ) 13.3.3 1400 mm sweep ( composite ) 13.4 rewinding of single / three phase motors rewinding of electric single phase / three phase motors not covered in item no 13.1 and 13.3, winding with copper wire, overhauling with minor repairs along with the replacement of minor parts, testing for the original speed & guarantee of minimum 6 months, having heneral guidelines as per itam no 13.1 and 13.3, allas per the instructions of e i c, es for inclusive cost as mentioned in the folloeing various items nos. 13.4.1 motors up to onefourth hp single phase. ( composite ) 13.4.2 motors up to half hp single phase. ( composite ) 13.4.3 1 hp single phase. ( composite ) 13.4.4 2 hp single phase ( composite ) 13.4.5 single phase 3 hp ( composite ) 13.4.6 up to 1 hp 3 phase ( composite ) 13.4.7 2 hp 3 phase ( composite ) 13.4.8 3 hp 3 phase ( composite ) 13.4.9 5 hp 3 phase ( composite ) 13.4.10 7.5 hp 3 phase ( composite ) 13.4.11 10 hp 3 phase ( composite ) 13.4.12 12.5 hp 3 phase ( composite ) 13.4.13 15 hp 3 phase ( composite ) 13.4.14 20 hp 3 phase ( composite ) 13.4.15 25 hp 3 phase ( composite ) 13.4.16 30 hp 3 phase ( composite ) 13.4.17 40 hp 3 phase ( composite ) 13.4.18 45 hp 3 phase ( composite ) 13.4.19 50 hp 3 phase ( composite ) 13.4.20 60 hp 3 phase ( composite ) 13.4.21 5 hp submersible pump, 3 ph. ( composite ) 13.4.22 3 hp submersible pump 3 ph ( composite ) 13.4.23 2 hp submersible pump 3 ph ( composite ) 13.4.24 2 hp submersible pump 1 ph ( composite ) 14.1 bearings replacing the worn out / unservicible existing ball of approved make of single phase three phase electric motor / other relevent applications of all types with proper alignment of shaft, greasing / oiling etc & testing at site sll as per the instructions of e i c, es. removed / replaced bearings shall be handed over to e i c, es as it is. ( gate pass / challans are to te submitted to e i c, es each time ) 14.1.1 2 hp to 3 hp ( only supply ) 14.1.2 2 hp to 3 hp ( only labour ) 14.1.3 2 hp to 3 hp ( composite ) 14.1.4 4 hp to 7.5 hp ( only supply ) 14.1.5 4 hp to 7.5 hp ( only labour ) 14.1.6 4 hp to 7.5 hp ( composite ) 14.1.7 10 hp to 20 hp ( only supply ) 14.1.8 10 hp to 20 hp ( only labour ) 14.1.9 10 hp to 20 hp ( composite ) 14.1.10 25 hp to 30 hp ( only supply ) 14.1.11 25 hp to 30 hp ( only labour ) 14.1.12 25 hp to 30 hp ( composite ) 14.1.13 35 hp to 40 hp ( only supply ) 14.1.14 35 hp to 40 hp ( only labour ) 14.1.15 35 hp to 40 hp ( composite ) 14.1.16 45 hp to 50 hp ( only supply ) 14.1.17 45 hp to 50 hp ( only labour ) 14.1.18 45 hp to 50 hp ( composite ) 14.1.19 60 hp to 75 hp ( only supply ) 14.1.20 60 hp to 75 hp ( only labour ) 14.1.21 60 hp to 75 hp ( composite ) 14.2 bearings / bushings / rotors 14.2.1 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only supply ) 14.2.2 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only labour ) 14.2.3 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site. refer guidelines as per item no 14.1 ( composite ) 14.2.4 replacement of shaft for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc ( only labour ) refer guidelines as per item no 14.1 as applicable for this item. 14.2.5 replacement of wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc.refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.6 replacement of non wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. 14.2.7 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( only supply ) 14.2.8 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item ( only labour ) 14.2.9 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.10 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only supply ) 14.2.11 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only labour ) 14.2.12 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( composite ) 14.2.13 painting of old fans, tube lights fixtures, motors or anyh other such application etc as decided and directed by e i c, es with enamel paint after coat of red oxide etc. ( note: this item is applicable only when specifically required for small / midium size erquipment coverd in section no 14. painting included in overhauling or repairs of any electrical equipment / instrument / machine does not come under this. ) ( composite ) 14.2.14 repairing of domestic mixer / grinder / blender or any other eqvuivalant domestic applience etc that includes replacement of indicators, switches, couplers, oiling, general servicing, or any other relvant spare part etc for all manufactures, all as per instructions of engineer in charge. replaced material shall be brought back & shall be submitted to e i c, whereever applicable ( composite ) . 14.2.15 all as per item no 14.2.14 but for replacement of bearing / bushings / blades etc. ( composite ) 14.2.16 all general guidelines as per item no 14.2.14 but for tea kettle excluding heating coil. ( composite ) 14.2.17 replacement of pump impeller ( composite ) 14.2.18 replacement of impeller for 3 hp pump ( composite ) 14.2.19 replacement of impeller for 5 hp pump ( composite ) 14.2.20 replacement of cooling fan for motor up to 2hp. 14.3 capacitors 14.3.1 replacing the defective capacitor of table fan / wall fan / pedestal fan / ceiling fan / dip freezer motor / street light fittings / fluorescent tube fittings or any other smilar application etc & testing at site. general guidelines for replacement shall be as per item no 14.1 as applicable, all as per instructions and as directed by e i c, es 14.3.1.1 1.5 mfd ( only supply ) 14.3.1.2 1.5 mfd ( only labour ) 14.3.1.3 1.5 mfd ( composite ) 14.3.1.4 2.5 mfd ( only supply ) 14.3.1.5 2.5 mfd ( only labour ) 14.3.1.6 2.5 mfd ( composite ) 14.3.1.7 4 mfd ( only supply ) 14.3.1.8 4 mfd ( only labour ) 14.3.1.9 4 mfd ( composite ) 14.3.1.10 5 / 6 mfd ( only supply ) 14.3.1.11 5 / 6 mfd ( only labour ) 14.3.1.12 5 / 6 mfd ( composite ) 14.3.1.13 10 / 15 mfd ( only supply ) 14.3.1.14 10 / 15 mfd ( only labour ) 14.3.1.15 10 / 15 mfd ( composite ) 14.3.1.16 20 mfd ( only supply ) 14.3.1.17 20 mfd ( only labour ) 14.3.1.18 20 mfd ( composite ) 14.3.1.19 33 mfd ( only supply ) 14.3.1.20 33 mfd ( only labour ) 14.3.1.21 33 mfd ( composite ) 14.3.1.22 40 mfd ( only supply ) 14.3.1.23 40 mfd ( only labour ) 14.3.1.24 40 mfd ( composite ) 14.3.1.25 60 mfd ( only supply ) 14.3.1.26 60 mfd ( only labour ) 14.3.1.27 60 mfd ( composite ) 14.3.1.28 80 mfd ( only supply ) 14.3.1.29 80 mfd ( only labour ) 14.3.1.30 80 mfd ( composite ) 14.3.1.31 120 mfd ( only supply ) 14.3.1.32 120 mfd ( only labour ) 14.3.1.33 120 mfd ( composite ) 14.3.1.34 200 mfd ( only supply ) 14.3.1.35 200 mfd ( only labour ) 14.3.1.36 200 mfd ( composite ) 14.4 coils / transformers 14.4.1 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) ( only supply ) 14.4.2 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es. ( only labour ) 14.4.3 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es ( composite ) . 14.4.4 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or any such other specific circuits / appplications. prior approval is required. ( only supply ) 14.4.5 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( only labour ) . 14.4.6 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( composite ) . 15.1 olr / starters / terminal boxes supply & replacement of thermal over load relay for motors or any other such application as decided by e i c, es including lugging, putting insulation tape ets. in case of replacement, removed / replaced parts shall be handed over to e i c, es along with gatepass / challans etc. 15.1.1 up to 7.5 hp ( only supply ) 15.1.2 up to 7.5 hp ( only labour ) 15.1.3 up to 7.5 hp ( composite ) 15.1.4 10 hp to 20 hp ( only supply ) 15.1.5 10 hp to 20 hp ( only labour ) 15.1.6 10 hp to 20 hp ( composite ) 15.1.7 25 hp to 30 hp ( only supply ) 15.1.8 25 hp to 30 hp ( only labour ) 15.1.9 25 hp to 30 hp ( composite ) 15.1.10 35 hp to 40 hp ( only supply ) 15.1.11 35 hp to 40 hp ( only labour ) 15.1.12 35 hp to 40 hp ( composite ) 15.1.13 45 hp to 50 hp ( only supply ) 15.1.14 45 hp to 50 hp ( only labour ) 15.1.15 45 hp to 50 hp ( composite ) 15.1.16 60 hp to 75 hp ( only supply ) 15.1.17 60 hp to 75 hp ( only labour ) 15.1.18 60 hp to 75 hp ( composite ) 15.2 supply, installation, testing & commissioning of dol starters, of reputed make make as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic. in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.2.1 up to 2 hp / 1.5 kw single phase. ( only supply ) 15.2.2 up to 2 hp / 1.5 kw single phase. ( only labour ) 15.2.3 up to 2 hp / 1.5 kw single phase. ( composite ) 15.2.4 up to 7.5 hp / 5.5 kw 3phase. ( only supply ) 15.2.5 up to 7.5 hp / 5.5 kw 3phase. ( only labour ) 15.2.6 up to 7.5 hp / 5.5 kw 3phase. ( composite ) 15.2.7 up to 10 hp ( only supply ) 15.2.8 up to 10 hp ( only labour ) 15.2.9 up to 10 hp ( composite ) 15.2.10 up to 20 hp, ( only supply ) 15.2.11 up to 20 hp, ( only labour ) 15.2.12 up to 20 hp, ( composite ) 15.2.13 for 30 hp. ( only supply ) 15.2.14 for 30 hp. ( only labour ) 15.2.15 for 30 hp. ( composite ) 15.2.16 for 40 hp. ( only supply ) 15.2.17 for 40 hp. ( only labour ) 15.2.18 for 40 hp. ( composite ) 15.3 supply, installation, testing & commissioning of fully automatic star delta motor starters, as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic.in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.3.1 up to 2 hp ( only supply ) 15.3.2 up to 2 hp ( only labour ) 15.3.3 up to 2 hp ( composite ) 15.3.4 up to 5 hp ( only supply ) 15.3.5 up to 5 hp ( only labour ) 15.3.6 up to 5 hp ( composite ) 15.3.7 up to 10 hp ( only supply ) 15.3.8 up to 10 hp ( only labour ) 15.3.9 up to 10 hp ( composite ) 15.3.10 up to 12.5 hp ( only supply ) 15.3.11 up to 12.5 hp ( only labour ) 15.3.12 up to 12.5 hp ( composite ) 15.3.13 up to 15 hp ( only supply ) 15.3.14 up to 15 hp ( only labour ) 15.3.15 up to 15 hp ( composite ) 15.3.16 up to 20 hp ( only supply ) 15.3.17 up to 20 hp ( only labour ) 15.3.18 up to 20 hp ( composite ) 15.3.19 up to 30 hp ( only supply ) 15.3.20 up to 30 hp ( only labour ) 15.3.21 up to 30 hp ( composite ) 15.3.22 up to 50 hp ( only supply ) 15.3.23 up to 50 hp ( only labour ) 15.3.24 up to 50 hp ( composite ) 15.3.25 up to 75 hp ( only supply ) 15.3.26 up to 75 hp ( only labour ) 15.3.27 up to 75 hp ( composite ) 15.3.28 providing & fixing of motor terminal boxes. up to 1 hp ( only supply ) 15.3.29 up to 1 hp ( only labour ) 15.3.30 up to 1 hp ( composite ) 15.3.31 up to 2 hp ( only supply ) 15.3.32 up to 2 hp ( only labour ) 15.3.33 up to 2 hp ( composite ) 15.3.34 up to 5 hp ( only supply ) 15.3.35 up to 5 hp ( only labour ) 15.3.36 up to 5 hp ( composite ) 15.3.37 up to 10 hp ( only supply ) 15.3.38 up to 10 hp ( only labour ) 15.3.39 up to 10 hp ( composite ) 15.3.40 up to 20 hp ( only supply ) 15.3.41 up to 20 hp ( only labour ) 15.3.42 up to 20 hp ( composite ) 15.3.43 up to 30 hp ( only supply ) 15.3.44 up to 30 hp ( only labour ) 15.3.45 up to 30 hp ( composite ) 15.3.46 up to 50 hp ( only supply ) 15.3.47 up to 50 hp ( only labour ) 15.3.48 up to 50 hp ( composite ) 15.3.49 up to 75 hp ( only supply ) 15.3.50 up to 75 hp ( only labour ) 15.3.51 up to 75 hp ( composite ) 16.1 registers / discharge registers register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 18030. ( only supply ) 16.2 register, kiyosh make, 10 kohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( only labour ) 16.3 register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( composite ) 16.4 discharge resistors for capacitor banks up to 100 kvar ( only supply ) 17.1 supply, installing of electrical consumable items with testing & commissioning of them as specifications & as per direction of engg in charge.in case of replacement / repairs, old materials shall be handed over to e i c, es along with gatepass / challans etc. all replacements are subjected to prior approval of o i c, es for any equivalent make, if make is not mentioned. ( kindly refer make list provided separately ) . it may be noted that minimum balance of these itmes are required to maintain on site for emerrgency use. 17.1.1 40 w fluorescent tube reputed make ( only supply ) 17.1.2 40 w fluorescent tube reputed make ( only labour ) 17.1.3 40 w fluorescent tube reputed make ( composite ) 17.1.4 36 w fluorescent tube reputed make ( only supply ) 17.1.5 36 w fluorescent tube reputed make ( only labour ) 17.1.6 36 w fluorescent tube reputed make ( composite ) 17.1.7 20 w fluorescent tube reputed make ( only supply ) 17.1.8 20 w fluorescent tube reputed make ( only labour ) 17.1.9 20 w fluorescent tube reputed make ( composite ) 17.1.10 18 w fluorescent tube reputed make ( only supply ) 17.1.11 18 w fluorescent tube reputed make ( only labour ) 17.1.12 18 w fluorescent tube reputed make ( composite ) 17.1.13 9 w pl s fluorescent tube reputed make ( only supply ) 17.1.14 9 w pl s fluorescent tube reputed make ( only labour ) 17.1.15 9 w pl s fluorescent tube reputed make ( composite ) 17.1.16 11 w pl s fluorescent tube reputed make ( only supply ) 17.1.17 11 w pl s fluorescent tube reputed make ( only labour ) 17.1.18 11 w pl s fluorescent tube reputed make ( composite ) 17.1.19 75 w comptalux lamp of reputed make ( only supply ) 17.1.20 75 w comptalux lamp of reputed make ( only labour ) 17.1.21 75 w comptalux lamp of reputed make ( composite ) 17.1.22 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only supply ) 17.1.23 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only labour ) 17.1.24 30 w germicidal fluorescent ulitrea violet tube of reputed make ( composite ) 17.1.25 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only supply ) 17.1.26 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only labour ) 17.1.27 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( composite ) 17.1.28 same as item no 17.1.22 but 2 or one and the half feet in length ( only supply ) 17.1.29 same as item no 17.1.22 but 2 or one and the half feet in length ( only labour ) 17.1.30 same as item no 17.1.22 but 2 or one and the half feet in length ( only composite ) 17.1.31 insect killer tube size 2 feet ( only supply ) 17.1.32 insect killer tube size 2 feet ( only labour ) 17.1.33 insect killer tube size 2 feet ( composite ) 17.1.34 insect killer tube size one and the half feet ( only supply ) 17.1.35 insect killer tube size one and the half feet ( only labour ) 17.1.36 insect killer tube size one and the half feet ( cokposite ) 17.1.37 100 w gls clear / milky lamp reputed make ( only supply ) 17.1.38 100 w gls clear / milky lamp reputed make ( only labour ) 17.1.39 100 w gls clear / milky lamp reputed make ( composite ) 17.1.40 200w clear / milky gls lamp ( only supply ) 17.1.41 200w clearmtilky gls lamp ( only labour ) 17.1.42 200w clearmtilky gls lamp ( composite ) 17.1.43 60 w gls clear / milky lamp reputed make ( only supply ) 17.1.44 60 w gls clear / milky lamp reputed make ( only labour ) 17.1.45 60 w gls clear / milky lamp reputed make ( composite ) 17.1.46 40 w clear / milky gls lamp ( only supply ) 17.1.47 40 w clear / miilky gls lamp ( only ) 17.1.48 40 w clear / milky gls lamp ( only supply ) 17.1.49 25 w clear / milky lamp reputed make ( only supply ) 17.1.50 25 w clear / milky lamp reputed make ( only labour ) 17.1.51 25 w clear / milky lamp reputed make ( composite ) 17.1.52 15 w red indication lamp reputed make / or other colour for any other specific application. ( supply ) 17.1.53 15 w red indication lamp reputed make / or other colour for any other specific application. ( labour ) 17.1.54 15 w red indication lamp reputed make / or other colour for any other specific application. ( composite ) 17.1.55 25 w incandescent lamp for exit light ( as per sample ) ( only supply ) 17.1.56 25 w incandescent lamp for exit light ( as per sample ) ( only labour ) 17.1.57 25 w incandescent lamp for exit light ( as per sample ) ( composite ) 17.1.58 8 w / 11w pin type cfl lamp ( only supply ) 17.1.59 8 w / 11w pin type cfl lamp ( only labour ) 17.1.60 8 w / 11w pin type cfl lamp ( composite ) 17.1.61 14 w pin type cfl lamp ( only supply ) 17.1.62 14 w pin type cfl lamp ( only labour ) 17.1.63 14 w pin type cfl lamp ( composite ) 17.1.64 23 / 25 w cfl tube ( only supply ) 17.1.65 23 / 25 w cfl tube ( only labour ) 17.1.66 23 / 25 w cfl tube ( composite ) 17.1.67 14 w plc tube ( only supply ) 17.1.68 14 w plc tube ( only labour ) 17.1.69 14 w plc tube ( composite ) 17.1.70 36 w pll tube light ( only supply ) 17.1.71 36 w pll tube light ( only labour ) 17.1.72 36 w pll tube light ( composite ) 17.1.73 electronic choke for 36 w pll fitting ( only supply ) 17.1.74 electronic choke for 36 w pll fitting ( only labour ) 17.1.75 electronic choke for 36 w pll fitting ( composite ) 17.1.76 40 w choke / ballast reputed make ( only supply ) 17.1.77 40 w choke / ballast reputed make ( only labour ) 17.1.78 40 w choke / ballast reputed make ( composite ) 17.1.79 electronic choke ( 40 w ) ( only supply ) 17.1.80 electronic choke ( 40 w ) ( only labour ) 17.1.81 electronic choke ( 40 w ) ( composite ) 17.1.82 20 w choke / ballast reputed make ( only supply ) 17.1.83 20 w choke / ballast reputed make ( only labour ) 17.1.84 20 w choke / ballast reputed make ( only composite ) 17.1.85 9 w choke / ballast reputed make ( only supply ) 17.1.86 9 w choke / ballast reputed make ( only labour ) 17.1.87 9 w choke / ballast reputed make ( composite ) 17.1.88 11 w choke / ballast reputed make ( only supply ) 17.1.89 11 w choke / ballast reputed make ( only labour ) 17.1.90 11 w choke / ballast reputed make ( composite ) 17.1.91 30 w choke / ballast for germicidal fixture gajjars make ( only supply ) 17.1.92 30 w choke / ballast for germicidal fixture gajjars make ( only labour ) 17.1.93 30 w choke / ballast for germicidal fixture gajjars make ( composite ) 17.1.94 fixing / replacing of side holders ( 1 no. ) ( only supply ) 17.1.95 fixing / replacing of side holders ( 1 no. ) ( only labour ) 17.1.96 fixing / replacing of side holders ( 1 no. ) ( composite ) 17.1.97 starter for fluorescent 36w tube light ( only supply ) 17.1.98 starter for fluorescent 36w tube light ( only labour ) 17.1.99 starter for fluorescent 36w tube light ( composite ) 17.1.100 replacing of starter holder for tube light ( only supply ) 17.1.101 replacing of starter holder for tube light ( only labour ) 17.1.102 replacing of starter holder for tube light ( composite ) 17.1.103 replacing of side holder for pl lamp fitting ( only supply ) 17.1.104 replacing of side holder for pl lamp fitting ( only labour ) 17.1.105 replacing of side holder for pl lamp fitting ( composite ) 17.1.106 replacing of halogen tube reputed make 500 w ( only supply ) 17.1.107 replacing of halogen tube reputed make 500 w ( only labour ) 17.1.108 replacing of halogen tube reputed make 500 w ( composite ) 17.1.109 replacing of halogen tube reputed make 1000 w ( only supply ) 17.1.110 replacing of halogen tube reputed make 1000 w ( only labour ) 17.1.111 replacing of halogen tube reputed make 1000 w ( composite ) 17.1.112 15 w ( pigmy lamp ) ( only supply ) 17.1.113 15 w ( pigmy lamp ) ( only labour ) 17.1.114 15 w ( pigmy lamp ) ( composite ) 17.1.115 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only supply ) 17.1.116 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only labour ) 17.1.117 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( composite ) 17.1.118 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only supply ) 17.1.119 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only labour ) 17.1.120 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( composite ) 17.1.121 18 w reputed make choke suitable for 18 w plc tubes ( only supply ) 17.1.122 18 w reputed make choke suitable for 18 w plc tubes ( only labour ) 17.1.123 18 w reputed make choke suitable for 18 w plc tubes ( composite ) 17.1.124 decorative general type table / wall / reading lamp ( plc / cfl / incandescent lamp compatible etc ) ( only supply ) 17.1.125 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only supply ) 17.1.126 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only labour ) 17.1.127 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( composite ) 17.1.128 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only supply ) 17.1.129 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only labour ) 17.1.130 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( composite ) 17.1.131 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only supply ) 17.1.132 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only labour ) 17.1.133 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( composite ) 17.1.134 fixing / replacement of 18 / 20w electronic choke ( only supply ) 17.1.135 fixing / replacement of 18 / 20w electronic choke ( only labour ) 17.1.136 fixing / replacement of 18 / 20w electronic choke ( composite ) 17.1.137 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only supply ) 17.1.138 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only labour ) 17.1.139 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( composite ) 17.1.140 fixing / replacement of 30w fluroscent tube ( only supply ) 17.1.141 fixing / replacement of 30w fluroscent tube ( only labour ) 17.1.142 fixing / replacement of 30w fluroscent tube ( composite ) 17.1.143 fixing / replacement of 9 / 11w electronic choke ( only supply ) 17.1.144 fixing / replacement of 9 / 11w electronic choke ( only labour ) 17.1.145 fixing / replacement of 9 / 11w electronic choke ( composite ) 17.1.146 fixing / replacement of 100w comptlux lamp ( only supply ) 17.1.147 fixing / replacement of 100w comptlux lamp ( only labour ) 17.1.148 fixing / replacement of 100w comptlux lamp ( composite ) 17.1.149 30w tube light 3feet ( only supply ) 17.1.150 30w tube light 3feet ( only labour ) 17.1.151 30w tube light 3feet ( composite ) 17.2 led lamps pin type / thread type 17.2.1 fixing / replacement of 2 / 3w led lamp ( only supply ) 17.2.2 fixing / replacement of 2 / 3w led lamp ( only labour ) 17.2.3 fixing / replacement of 2 / 3w led lamp ( composite ) 17.2.4 fixing / replacement of 5 / 7 / 9w led lamp ( only supply ) 17.2.5 fixing / replacement of 5 / 7 / 9w led lamp ( only labour ) 17.2.6 fixing / replacement of 5 / 7 / 9w led lamp ( composite ) 17.2.7 fixing / replacement of 12w led lamp ( only supply ) 17.2.8 fixing / replacement of 12w led lamp ( only labour ) 17.2.9 fixing / replacement of 12w led lamp ( composite ) 17.2.10 fixing / replacement of 15w led lamp ( only supply ) 17.2.11 fixing / replacement of 15w led lamp ( only labour ) 17.2.12 fixing / replacement of 15w led lamp ( composite ) 17.2.13 fixing / replacement of 18w led lamp ( only supply ) 17.2.14 fixing / replacement of 18w led lamp ( only labour ) 17.2.15 fixing / replacement of 18w led lamp ( composite ) 17.2.16 fixing / replacement of 8w 2 long led tube ( only supply ) 17.2.17 fixing / replacement of 8w 2 long led tube ( only labour ) 17.2.18 fixing / replacement of 8w 2 long led tube ( composite ) 17.2.19 fixing / replacement of 18w led pll lamp ( only supply ) 17.2.20 fixing / replacement of 18w led pll lamp ( only labour ) 17.2.21 fixing / replacement of 18w led pll lamp ( composite ) 17.2.22 fixing / replacement of 30w led lamp ( only supply ) 17.2.23 fixing / replacement of 30w led lamp ( only labour ) 17.2.24 fixing / replacement of 30w led lamp ( composite ) 17.2.25 fixing / replacement of 35w led lamp ( only supply ) 17.2.26 fixing / replacement of 35w led lamp ( only labour ) 17.2.27 fixing / replacement of 35w led lamp ( composite ) 17.3 led driver 17.3.1 fixing / replacement of 3 / 5w led driver ( only supply ) 17.3.2 ffixing / replacement 3 / 5w led driver ( only labour ) 17.3.3 fixing / replacement of 3 / 5w led driver ( composite ) 17.3.4 fixing / replacement of 9w led driver ( only supply ) 17.3.5 ffixing / replacement 9w led driver ( only labour ) 17.3.6 fixing / replacement of 9w led driver ( composite ) 17.3.7 fixing / replacement of 12 / 15w led driver ( only supply ) 17.3.8 ffixing / replacement 12 / 15w led driver ( only labour ) 17.3.9 fixing / replacement of 12 / 15w led driver ( composite ) 17.3.10 fixing / replacement of 18w led driver ( only supply ) 17.3.11 ffixing / replacement 18w led driver ( only labour ) 17.3.12 fixing / replacement of 18w led driver ( composite ) 17.3.13 fixing / replacement of 24w led driver ( only supply ) 17.3.14 ffixing / replacement 24w led driver ( only labour ) 17.3.15 fixing / replacement of 24w led driver ( composite ) 17.3.16 fixing / replacement of 30w led driver ( only supply ) 17.3.17 ffixing / replacement 30w led driver ( only labour ) 17.3.18 fixing / replacement of 30w led driver ( composite ) 17.3.19 fixing / replacement of 36w led driver ( only supply ) 17.3.20 ffixing / replacement 36w led driver ( only labour ) 17.3.21 fixing / replacement of 36w led driver ( composite ) 18.1 gyesers / heaters supply, installation, testing & commissining of various types of water gyesers, heaters, heating coils, hot plates, strip heaters or any similar application heating equipment as per the required specifications as per instructions & as directed by e i c, es. in case of replacement / repairs, old items are to be handed over to e i c, es along with gatepass / challans etc. 18.1.1 25 litre capacity , hospital use water heater ( only supply ) 18.1.2 25 litre capacity , hospital use water heater ( only labour ) 18.1.3 25 litre capacity , hospital use water heater ( composite ) 18.1.4 reputed make 6 litre capacity , hospital use water heater ( only supply ) 18.1.5 reputed make 6 litre capacity , hospital use water heater ( only labour ) 18.1.6 reputed make 6 litre capacity , hospital use water heater ( composite ) 18.1.7 reputed make 1 litre capacity water geyser ( only supply ) 18.1.8 reputed make 1 litre capacity water geyser ( only labour ) 18.1.9 reputed make 1 litre capacity water geyser ( composite ) 18.1.10 reputed make 2 litre capacity water geyser ( only supply ) 18.1.11 reputed make 2 litre capacity water geyser ( only labour ) 18.1.12 reputed make 2 litre capacity water geyser ( composite ) 18.1.13 reputed make 3 litre capacity water geyser ( only supply ) 18.1.14 reputed make 3 litre capacity water geyser ( only labour ) 18.1.15 reputed make 3 litre capacity water geyser ( composite ) 18.2 thermostats and heating coils. 18.2.1 thermostat of good quality for all types of gysers ( only supply ) 18.2.2 thermostat of good quality for all types of gysers ( only labour ) 18.2.3 thermostat of good quality for all types of gysers ( composite ) 18.2.4 thermostats0 300 oc for oven ( only supply ) 18.2.5 thermostats0 300 oc for oven ( only labour ) 18.2.6 thermostats0 300 oc for oven ( composite ) 18.2.7 supply / replacement of coil for hot plate ( only supply ) 18.2.8 supply / replacement of coil for hot plate ( only supply ) 18.2.9 supply / replacement of coil for hot plate ( only supply ) 18.2.10 supply / replacement of coil for iron ( only supply ) 18.2.11 supply / replacement of coil for iron ( only labour ) 18.2.12 supply / replacement of coil for iron ( composite ) 18.2.13 fixing / replacement of coil / tube type heaters for geysers1000 w ( only supply ) 18.2.14 fixing / replacement of coil / tube type heaters for geysers1000 w ( only labour ) 18.2.15 fixing / replacement of coil / tube type heaters for geysers1000 w ( composite ) 18.2.16 fixing / replacement of coil / tube type heaters for geysers1500 w ( only supply ) 18.2.17 fixing / replacement of coil / tube type heaters for geysers1500 w ( only labour ) 18.2.18 fixing / replacement of coil / tube type heaters for geysers1500 w ( composite ) 18.2.19 fixing / replacement of coil / tube type heaters for geysers2000 w ( only supply ) 18.2.20 fixing / replacement of coil / tube type heaters for geysers2000 w ( only labour ) 18.2.21 fixing / replacement of coil / tube type heaters for geysers2000 w ( composite ) 18.2.22 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only supply ) 18.2.23 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only labour ) 18.2.24 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( composite ) 18.2.25 3000 w ( idli / chapati maker etc ) ( only supply ) 18.2.26 3000 w ( idli / chapati maker etc ) ( only labour ) 18.2.27 3000 w ( idli / chapati maker etc ) ( composite ) 18.2.28 500 w coil heater ( only supply ) 18.2.29 500 w coil heater ( only labour ) 18.2.30 500 w coil heater ( composite ) 18.2.31 replacement of kettle heaters ( only supply ) 18.2.32 replacement of kettle heaters ( only labour ) 18.2.33 replacement of kettle heaters ( composite ) 18.2.34 replacement of over load relay for gysers / hot plates and other similar equipments. ( only supply ) 18.2.35 replacement of over load relay for gysers / hot plates and other similar equipments. ( only labour ) 18.2.36 replacement of over load relay for gysers / hot plates and other similar equipments. ( composite ) 18.2.37 replacement of sealer coil ( only supply ) 18.2.38 replacement of sealer coil ( only labour ) 18.2.39 replacement of sealer coil ( composite ) 18.3 strip heaters. 18.3.1 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only supply ) 18.3.2 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only labour ) 18.3.3 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( composite ) 18.3.4 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only supply ) 18.3.5 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only labour ) 18.3.6 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( composite ) 18.3.7 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.8 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.9 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.10 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.11 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.12 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.13 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.14 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.15 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( composite ) 19.1.a mv cable work supply. installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round / flat wire armoured copper / al conductor power cables isi mark reputed make fixed on wall / column / ceiling or in shaft / existing trench on 6 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.1.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.1.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.1.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.1.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.1.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.1.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.1.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.1.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.1.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.1.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.1.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.1.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.1.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.1.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.1.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.1.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.1.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.1.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.1.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.1.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.1.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.2 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.2.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.2.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.2.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.2.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.2.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.2.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.2.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.2.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.2.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.2.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.2.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.2.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.2.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.2.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.2.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.2.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.2.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.2.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.2.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.2.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.2.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.3 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.3.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.3.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.3.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.3.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.3.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.3.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.3.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.3.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.3.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.3.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.3.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.3.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.3.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.3.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.3.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.3.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.3.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.3.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.3.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.3.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.3.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.4 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured copper / aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench on 5 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.4.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.4.2. 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.4.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.4.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.4.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.4.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.4.7 4 x 4 sq. mm copper conductor ( only supply ) 19.4.8 4 x 4 sq. mm copper conductor ( only labour ) 19.4.9 4 x 4 sq. mm copper conductor ( composite ) 19.4.10 4 x 6 sq. mm copper conductor ( only supply ) 19.4.11 4 x 6 sq. mm copper conductor ( only labour ) 19.4.12 4 x 6 sq. mm copper conductor ( composite ) 19.4.13 4 x 10 sq. mm copper conductor ( only supply ) 19.4.14 4 x 10 sq. mm copper conductor ( only labour ) 19.4.15 4 x 10 sq. mm copper conductor ( composite ) 19.4.16 4 x 16 sq. mm copper conductor ( only supply ) 19.4.17 4 x 16 sq. mm copper conductor ( only labour ) 19.4.18 4 x 16 sq. mm copper conductor ( composite ) 19.4.19 4 x 25 sq. mm copper conductor ( only supply ) 19.4.20 4 x 25 sq. mm copper conductor ( only labour ) 19.4.21 4 x 25 sq. mm copper conductor ( composite ) 19.4.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.4.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.4.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.4.25 4 x 10 sq. mm al conductor ( only supply ) 19.4.26 4 x 10 sq. mm al conductor ( only labour ) 19.4.27 4 x 10 sq. mm al conductor ( composite ) 19.4.28 4 x 16 sq. mm al conductor ( only supply ) 19.4.29 4 x 16 sq. mm al conductor ( only labour ) 19.4.30 4 x 16 sq. mm al conductor ( composite ) 19.4.31 4 x 25 sq. mm al conductor ( only supply ) 19.4.32 4 x 25 sq. mm al conductor ( only labour ) 19.4.33 4 x 25 sq. mm al conductor ( composite ) 19.4.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.4.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.4.36 3.5 x 25 sq. mm al conducto ( composite ) 19.4.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.4.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.4.39 3.5 x 35 sq. mm al conductor ( composite ) 19.4.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.4.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.4.42 3.5 x 50 sq. mm al conducto ( composite ) 19.4.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.4.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.4.45 3.5 x 70 sq. mm al conductor ( composite ) 19.4.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.4.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.4.48 3.5 x 95 sq. mm al conductor ( composite ) 19.5 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.5.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.5.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.5.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.5.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.5.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.5.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.5.7 4 x 4 sq. mm copper conductor ( only supply ) 19.5.8 4 x 4 sq. mm copper conductor ( only labour ) 19.5.9 4 x 4 sq. mm copper conductor ( composite ) 19.5.10 4 x 6 sq. mm copper conductor ( only supply ) 19.5.11 4 x 6 sq. mm copper conductor ( only labour ) 19.5.12 4 x 6 sq. mm copper conductor ( composite ) 19.5.13 4 x 10 sq. mm copper conductor ( only supply ) 19.5.14 4 x 10 sq. mm copper conductor ( only labour ) 19.5.15 4 x 10 sq. mm copper conductor ( composite ) 19.5.16 4 x 16 sq. mm copper conductor ( only supply ) 19.5.17 4 x 16 sq. mm copper conductor ( only labour ) 19.5.18 4 x 16 sq. mm copper conductor ( composite ) 19.5.19 4 x 25 sq. mm copper conductor ( only supply ) 19.5.20 4 x 25 sq. mm copper conductor ( only labour ) 19.5.21 4 x 25 sq. mm copper conductor ( composite ) 19.5.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.5.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.5.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.5.25 4 x 10 sq. mm al conductor ( only supply ) 19.5.26 4 x 10 sq. mm al conductor ( only labour ) 19.5.27 4 x 10 sq. mm al conductor ( composite ) 19.5.28 4 x 16 sq. mm al conductor ( only supply ) 19.5.29 4 x 16 sq. mm al conductor ( only labour ) 19.5.30 4 x 16 sq. mm al conductor ( composite ) 19.5.31 4 x 25 sq. mm al conductor ( only supply ) 19.5.32 4 x 25 sq. mm al conductor ( only labour ) 19.5.33 4 x 25 sq. mm al conductor ( composite ) 19.5.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.5.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.5.36 3.5 x 25 sq. mm al conducto ( composite ) 19.5.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.5.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.5.39 3.5 x 35 sq. mm al conductor ( composite ) 19.5.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.5.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.5.42 3.5 x 50 sq. mm al conducto ( composite ) 19.5.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.5.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.5.45 3.5 x 70 sq. mm al conductor ( composite ) 19.5.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.5.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.5.48 3.5 x 95 sq. mm al conductor ( composite ) 19.6 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.6.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.6.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.6.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.6.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.6.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.6.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.6.7 4 x 4 sq. mm copper conductor ( only supply ) 19.6.8 4 x 4 sq. mm copper conductor ( only labour ) 19.6.9 4 x 4 sq. mm copper conductor ( composite ) 19.6.10 4 x 6 sq. mm copper conductor ( only supply ) 19.6.11 4 x 6 sq. mm copper conductor ( only labour ) 19.6.12 4 x 6 sq. mm copper conductor ( composite ) 19.6.13 4 x 10 sq. mm copper conductor ( only supply ) 19.6.14 4 x 10 sq. mm copper conductor ( only labour ) 19.6.15 4 x 10 sq. mm copper conductor ( composite ) 19.6.16 4 x 16 sq. mm copper conductor ( only supply ) 19.6.17 4 x 16 sq. mm copper conductor ( only labour ) 19.6.18 4 x 16 sq. mm copper conductor ( composite ) 19.6.19 4 x 25 sq. mm copper conductor ( only supply ) 19.6.20 4 x 25 sq. mm copper conductor ( only labour ) 19.6.21 4 x 25 sq. mm copper conductor ( composite ) 19.6.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.6.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.6.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.6.25 4 x 10 sq. mm al conductor ( only supply ) 19.6.26 4 x 10 sq. mm al conductor ( only labour ) 19.6.27 4 x 10 sq. mm al conductor ( composite ) 19.6.28 4 x 16 sq. mm al conductor ( only supply ) 19.6.29 4 x 16 sq. mm al conductor ( only labour ) 19.6.30 4 x 16 sq. mm al conductor ( composite ) 19.6.31 4 x 25 sq. mm al conductor ( only supply ) 19.6.32 4 x 25 sq. mm al conductor ( only labour ) 19.6.33 4 x 25 sq. mm al conductor ( composite ) 19.6.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.6.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.6.36 3.5 x 25 sq. mm al conducto ( composite ) 19.6.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.6.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.6.39 3.5 x 35 sq. mm al conductor ( composite ) 19.6.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.6.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.6.42 3.5 x 50 sq. mm al conducto ( composite ) 19.6.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.6.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.6.45 3.5 x 70 sq. mm al conductor ( composite ) 19.6.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.6.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.6.48 3.5 x 95 sq. mm al conductor ( composite ) 19.7 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous 8 swg copper bare wire for earthing & end termination. 19.7.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.7.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.7.3 3.5 x 120 sq. mm al conductor ( composite ) 19.7.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.7.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.7.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.7.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.7.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.7.9 3.5 x 185 sq. mm al conductor ( composite ) 19.7.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.7.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.7.12 3.5 x 240 sq. mm al conductor ( composite ) 19.7.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.7.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.7.15 3.5 x 300 sq. mm al conductor ( composite ) 19.7.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.7.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.7.18 3.5 x 400 sq. mm al conductor ( composite ) 19.8 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.8.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.8.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.8.3 3.5 x 120 sq. mm al conductor ( composite ) 19.8.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.8.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.8.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.8.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.8.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.8.9 3.5 x 185 sq. mm al conductor ( composite ) 19.8.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.8.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.8.12 3.5 x 240 sq. mm al conductor ( composite ) 19.8.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.8.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.8.15 3.5 x 300 sq. mm al conductor ( composite ) 19.8.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.8.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.8.18 3.5 x 400 sq. mm al conductor ( composite ) 19.9 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.9.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.9.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.9.3 3.5 x 120 sq. mm al conductor ( composite ) 19.9.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.9.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.9.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.9.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.9.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.9.9 3.5 x 185 sq. mm al conductor ( composite ) 19.9.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.9.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.9.12 3.5 x 240 sq. mm al conductor ( composite ) 19.9.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.9.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.9.15 3.5 x 300 sq. mm al conductor ( composite ) 19.9.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.9.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.9.18 3.5 x 400 sq. mm al conductor ( composite ) 19.10.a supply, installation, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark make fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous copper strip / wire earthing as required & as directed by o i c, es. 19.10.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.10.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.10.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.10.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.10.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.10.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.11 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark pvc insulated isi mark armored, bright annealed copper conductor cable below earth 1200 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.11.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.11.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.11.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.11.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.11.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.11.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.12 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11kv grade cable, isi mark , laying in ground at 1200 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.12.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.12.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.12.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.12.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.12.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.12.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 20.1 gi pipes / foot valvessupply, installation gi pipes class b type with all fixing arrangement such as couplings, bends etc on any kind of surface or below ground as per the instruction of e i c. 20.1.1 gi pipe 25 mm ( only supply ) 20.1.2 gi pipe 25 mm ( only labour ) 20.1.3 gi pipe 25 mm ( composite ) 20.1.4 gi pipe 32 mm ( only supply ) 20.1.5 gi pipe 32 mm ( only labour ) 20.1.6 gi pipe 32 mm ( composite ) 20.1.7 gi pipe 38 mm ( only supply ) 20.1.8 gi pipe 38 mm ( only labour ) 20.1.9 gi pipe 38 mm ( composite ) 20.1.10 gi pipe 50 mm ( only supply ) 20.1.11 gi pipe 50 mm ( only labour ) 20.1.12 gi pipe 50 mm ( composite ) 20.2 supply / replacement of foot valve of various sizes with all necessary arrangement for making it properly function, all as per the instructions and as per directions of e i c, es 20.2.1 threefourth inch ( only supply ) 20.2.2 threefourth inch ( only labour ) 20.2.3 threefourth inch ( composite ) 20.2.4 1inch ( only supply ) 20.2.5 1inch ( only labour ) 20.2.6 1inch ( composite ) 20.2.7 2inch ( only supply ) 20.2.8 2inch ( only labour ) 20.2.9 2inch ( composite ) 20.2.10 3inch ( only supply ) 20.2.11 3inch ( only labour ) 20.2.12 3inch ( composite ) 20.3 exavation / hume pipes / dwc pipes 20.3.1 supply, installation of oval / circular shape gi casted cable marker complete with 38 m dia gi support 1: 3: 6 pcc base, concreting / gi nut bolts, engraved as ht / mv / lt / tel.cables etc. as per instruction of eic. all as directed by o i c with prior approval. ( composite ) 20.3.2 exavation of all kind of soil as per required 900 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, reinstatement, after work completion, if necessary disposal of excess earth within the radius of 500 mtrs etc, stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.3 exavation of hard rock as per reuired 900 / 1200 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, if necessary disposal of excess earth within the radius of 500 mtrs etc. stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 21 supply, laying, testing & commissioning of rg 11 television cable through casing capping / pvc conduits / gi ms pipes on any kind of surface / below ground through dwc pipe through out the campus as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es. 21.1 rg 11 cable ( only supply ) 21.2 rg 11 cable supply and laying pvc casing capping / conduit pipe ( composite ) 21.3 rg 11 cable laying through dwc hdpe pipe pipe ( composite ) 21.10.a supply of rg 59 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.11 laying of rg 59 television cable through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.12 supply, laying, testing & commissioning of rg 59 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 21.13 supply of rg 6 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.14 laying of rg 6 television cable through provided casing capping / pvc conduits / gi ms pipes any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.15 supply, laying, testing & commissioning of rg 6 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 22 corrogated water pipe 22.1 supply / replacement of corrogated water pipe with prior approval will all accessories and fixing arrangement, all as per instructions and as directed by e i c, es. 22.1.1 threefourth inch ( only supply ) 22.1.2 threefourth inch ( only labour ) 22.1.3 threefourth inch ( composite ) 22.1.4 1inch ( only supply ) 22.1.5 1inch ( only labour ) 22.1.6 1inch ( composite ) 22.1.7 2inch ( only supply ) 22.1.8 2inch ( only labour ) 22.1.9 2inch ( composite ) 22.1.10 3inch ( only supply ) 22.1.11 3inch ( only labour ) 22.1.12 3inch ( composite ) 23.1 telephone cable / joint kits / tag blockssupply, installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed cable fixed on slab / wall / coloum / existing trench etc. on 6 mm thick gi spacer / ms flat support with wooden screws with 18 swg gi saddle all fixing accessories & jointing of the both the ends of cable s with all jointing materials like cable glands, cable end box if required, ferrule lugs, ferrule numbers, wire dressing clamps / buttons etc. complete all as per instruction of e i c. 23.1.1 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only supply ) 23.1.2 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only labour ) 23.1.3 as per item no 23.1 but for 0.5 mm dia 10 pair. ( composite ) 23.1.4 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only supply ) 23.1.5 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only labour ) 23.1.6 as per item no 23.1 but for 0.5 mm dia 20 pair. ( composite ) 23.1.7 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only supply ) 23.1.8 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only labour ) 23.1.9 as per item no 23.1 but for 0.5 mm dia 50 pair. ( composite ) 23.1.10 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only supply ) 23.1.11 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only labour ) 23.1.12 as per item no 23.1 but for 0.5 mm dia 100 pair. ( composite ) 23.1.13 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only supply ) 23.1.14 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only labour ) 23.1.15 as per item no 23.1 but for 0.5 mm dia 200 pair. ( composite ) 23.2 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of soil / sand bedding laying of backed bricks as per is on side & top, back filling dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.2.1 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only supply ) 23.2.2 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only labour ) 23.2.3 as per item no 23.2 but for 0.5 mm dia 10 pair. ( composite ) 23.2.4 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only supply ) 23.2.5 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only labour ) 23.2.6 as per item no 23.2 but for 0.5 mm dia 20 pair. ( composite ) 23.2.7 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only supply ) 23.2.8 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only labour ) 23.2.9 as per item no 23.2 but for 0.5 mm dia 50 pair. ( composite ) 23.2.10 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only supply ) 23.2.11 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only labour ) 23.2.12 as per item no 23.2 but for 0.5 mm dia 100 pair. ( composite ) 23.2.13 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only supply ) 23.2.14 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only labour ) 23.2.15 as per item no 23.2 but for 0.5 mm dia 200 pair. ( composite ) 23.3 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of laying through suitable dwc hdpe pipe, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.3.1 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only supply ) 23.3.2 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only labour ) 23.3.3 as per item no 23.3 but for 0.5 mm dia 10 pair. ( composite ) 23.3.4 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only supply ) 23.3.5 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only labour ) 23.3.6 as per item no 23.3 but for 0.5 mm dia 20 pair. ( composite ) 23.3.7 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only supply ) 23.3.8 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only labour ) 23.3.9 as per item no 23.3 but for 0.5 mm dia 50 pair. ( composite ) 23.3.10 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only supply ) 23.3.11 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only labour ) 23.3.12 as per item no 23.3 but for 0.5 mm dia 100 pair. ( composite ) 23.3.13 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only supply ) 23.3.14 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only labour ) 23.3.15 as per item no 23.3 but for 0.5 mm dia 200 pair. ( composite ) 23.4 supply, installation, testing & commissioning of straight through telephone jointing kits preferably of raychem make or alternately m seal of mahindra make for jelly filled armoured telephone cable including dressing, cleaning of the jelly, supply of all jointing materials, etc. complete as required and as per relevant specifications and as directed by e i c. 23.4.1 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only supply ) 23.4.2 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only labour ) 23.4.3 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( composite ) 23.4.4 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only supply ) 23.4.5 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only labour ) 23.4.6 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( composite ) 23.4.7 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only supply ) 23.4.8 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only labour ) 23.4.9 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( composite ) 23.4.10 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only supply ) 23.4.11 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only labour ) 23.4.12 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( composite ) 23.4.13 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only supply ) 23.4.14 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only labour ) 23.4.15 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( composite ) 23.5 supply, installation, testing & commissioning of crone connector telephone tag block box, fabricated out of 14 swg ms crca sheet mounted on ms frame of size 40 x 40 x 5 mm & grouted on the wall / fixed on the coloum free standing type with anchor fastener with front openable hinged doors cam type locking arrangements, neoprene gasket for joints painting with seven tank metal treatment process & with two coats of red oxide primer & two coats of approved shade enamel paint, norm plate etc. as per the instruction of eic. 23.5.1 2 x 10 ways telephone tag block. ( only supply ) 23.5.2 2 x 10 ways telephone tag block. ( only labour ) 23.5.3 2 x 10 ways telephone tag block. ( composite ) 23.5.4 2 x 20 ways telephone tag block. ( only supply ) 23.5.5 2 x 20 ways telephone tag block. ( only labour ) 23.5.6 2 x 20 ways telephone tag block. ( composite ) 23.5.7 2 x 50 ways telephone tag block. ( only supply ) 23.5.8 2 x 50 ways telephone tag block. ( only labour ) 23.5.9 2 x 50 ways telephone tag block. ( composite ) 23.5.10 2 x 60 ways telephone tag block. ( only supply ) 23.5.11 2 x 60 ways telephone tag block. ( only labour ) 23.5.12 2 x 60 ways telephone tag block. ( composite ) 23.5.13 2 x 100 ways telephone tag block. ( only supply ) 23.5.14 2 x 100 ways telephone tag block. ( only labour ) 23.5.15 2 x 100 ways telephone tag block. ( composite ) 23.5.16 2 x 200 ways telephone tag block. ( only supply ) 23.5.17 2 x 200 ways telephone tag block. ( only labour ) 23.5.18 2 x 200 ways telephone tag block. ( composite ) 23.5.19 2 x 240 ways telephone tag block. ( only supply ) 23.5.20 2 x 240 ways telephone tag block. ( only labour ) 23.5.21 2 x 240 ways telephone tag block. ( composite ) 23.5.22 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only supply ) 23.5.23 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only labour ) 23.5.24 supply & fixing of 10 way crone connectors of good quality with prior approval. ( composite ) 24.1 cable glands and lugssupplying & erecting heavy duty flange type brass cable glands for end jointing of various sizes for pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected, with gland double earthing, work completed in all respect all as per instructions and as directed by e i c, es 24.1.1 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only supply ) 24.1.2 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only labour ) 24.1.3 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( composite ) 24.1.4 as per item no 24.1 but for but 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm as per item no 24.1 but for ( only supply ) 24.1.5 as per item no 24.1 but for 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( only labour ) 24.1.6 same as abovebut 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( composite ) 24.1.7 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only supply ) 24.1.8 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only labour ) 24.1.9 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( composite ) 24.1.10 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only supply ) 24.1.11 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only labour ) 24.1.12 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( composite ) 24.1.13 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only supply ) 24.1.14 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only labour ) 24.1.15 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( composite ) 24.1.16 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only supply ) 24.1.17 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only labour ) 24.1.18 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( composite ) 24.1.19 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only supply ) 24.1.20 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only labour ) 24.1.21 as per item no 24.1 but for 3.5 x 95 sq.mmsame as above ( composite ) 24.1.22 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( only supply ) 24.1.23 as per item no 24.1 but for 3.5 x 120 sq.mmsame as above ( only labour ) 24.1.24 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( composite ) 24.1.25 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only supply ) 24.1.26 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only labour ) 24.1.27 as per item no 24.1 but for 3.5 x 150 sq.mmsame as above ( composite ) 24.1.28 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only supply ) 24.1.29 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only labour ) 24.1.30 as per item no 24.1 but for 3.5 x 185 sq.mm same as above ( compsite ) 24.1.31 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only supply ) 24.1.32 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only labour ) 24.1.33 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( composite ) 24.1.34 as per item no 24.1 but for 3.5 x 300 sq.mmsame as above ( only supply ) 24.1.35 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( only labour ) 24.1.36 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( composite ) 24.1.37 as per item no 24.1 but for 3.5 x 400 sq.mmsame as above ( only supply ) 24.1.38 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( only labour ) 24.1.39 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( composite ) 24.2 lugs supplying & erecting crimping type copper lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.2.1 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only supply ) 24.2.2 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only labour ) 24.2.3 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( composite ) 24.2.4 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only supply ) 24.2.5 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only labour ) 24.2.6 as per item no 24.2 but for 25 sq. mm as per item no 24.2 but for ( composite ) 24.2.7 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only supply ) 24.2.8 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only labour ) 24.2.9 as per item no 24.2 but for 35 sq. mmas per item no 24.2 but for ( composite ) 24.2.10 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only supply ) 24.2.11 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only labour ) 24.2.12 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( composite ) 24.2.13 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( only supply ) 24.2.14 as per item no 24.2 but for 70 sq. mmas per item no 24.2 but for ( only labour ) 24.2.15 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( composite ) 24.2.16 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( only supply ) 24.2.17 as per item no 24.2 but for 95 sq. mm as per item no 24.2 but for ( only labour ) 24.2.18 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( composite ) 24.2.19 as per item no 24.2 but for 120 sq. mmas per item no 24.2 but for ( only supply ) 24.2.20 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( only labour ) 24.2.21 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( composite ) 24.2.22 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only supply ) 24.2.23 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only labour ) 24.2.24 as per item no 24.2 but for 150 sq. mm as per item no 24.2 but for ( composite ) 24.2.25 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( only supply ) 24.2.26 as per item no 24.2 but for 185 sq. mm as per item no 24.2 but for ( only labour ) 24.2.27 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( composite ) 24.2.28 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( only supply ) 24.2.29 as per item no 24.2 but for 240 sq. mm as per item no 24.2 but for ( only labour ) 24.2.30 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( composite ) 24.2.31 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( only supply ) 24.2.32 as per item no 24.2 but for 300 sq. mm as per item no 24.2 but for ( only labour ) 24.2.33 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( composite ) 24.2.34 as per item no 24.2 but for 400 sq. mmas per item no 24.2 but for ( only supply ) 24.2.35 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( only labour ) 24.2.36 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( composite ) 24.3 supplying & erecting crimping type aluminium lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.3.1 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only supply ) 24.3.2 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only labour ) 24.3.3 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( composite ) 24.3.4 as per item no 24.3 but for 25 sq. mm as per item no 24.3 but for ( only supply ) 25.1 flexible cable / borewell cablesupply & fixing of white / black colour pvc insulation of various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc. all as directed by o i c, es. 25.1.1 3 x 1.5 sq. mm flexible cable ( only supply ) 25.1.2 3 x 1.5 sq. mm flexible cable ( only labour ) 25.1.3 3 x 1.5 sq. mm flexible cable ( composite ) 25.1.4 3 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.5 3 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.6 3 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.7 3 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.8 3 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.9 3 x 4 sq. mm pvc flexible cable ( composite ) ) 25.1.10 2 x 1.5 sq. mm pvc flexible cable ( only supply ) 25.1.11 2 x 1.5 sq. mm pvc flexible cable ( only labour ) 25.1.12 2 x 1.5 sq. mm pvc flexible cable ( composite ) 25.1.13 2 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.14 2 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.15 2 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.16 4 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.17 4 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.18 4 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.19 4 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.20 4 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.21 4 x 4 sq. mm pvc flexible cable ( composite ) 25.2 supply & fixing of pvc insulated various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc for bore well connection, all as directed by o i c, es. 25.2.1 3c x 1.5 sq. mm cable ( only supply ) 25.2.2 3c x 1.5 sq. mm cable ( only labour ) 25.2.3 3c x 1.5 sq. mm cable ( composite ) 25.2.4 3c x 2.5 sq. mm cable ( only supply ) 25.2.5 3c x 2.5 sq. mm cable ( only labour ) 25.2.6 3c x 2.5 sq. mm cable ( composite ) 25.2.7 3c x 4 sq. mm cable ( only supply ) 25.2.8 3c x 4 sq. mm cable ( only labour ) 25.2.9 3c x 4 sq. mm cable ( composite ) 26 water level controller 26.1 supply, installation, testing & commissioning of water level controller for maintaining of desired level of water in water tank etc, having all sensing mechanium in place, as complete unit, with all other necessary arrangement of proper finctioning etc, all as per instruction and as per derection of e i c, es 26.1.1 automatic water level controller with sensor ( only supply ) 26.1.2 automatic water level controller with sensor ( only labour ) 26.1.3 automatic water level controller with sensor ( composite ) 26.1.4 sensor for water level controller ( only supply ) 26.1.5 sensor for water level controller ( only labour ) 26.1.6 sensor for water level controller ( composite ) 26.1.7 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.8 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.9 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.10 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 5.8 / 8.5 liters per sec. for head of 20 / 36 m and 65 mm suction / 50mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.11 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.12 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.13 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.14 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.15 supplying and erecting submercible water pump set suitable for erection on open well of 5 hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 26.1.16 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.17 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.18 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 27.1 earthingsupplying & installation of tinned copper strip / bare copper wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continity test etc & all as directed by engg. in charge. 27.1.1 8 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.2 8 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.3 8 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.4 10 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.5 10 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.6 10 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.7 12 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.8 12 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.9 12 swg tinned copper bare wire ( 1 run ) ( only composite ) 27.1.10 14 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.11 14 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.12 14 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.13 16 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.14 16 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.15 16 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.16 copper strip of size 25 x 3 mm ( 1 run ) ( only supply ) 27.1.17 copper strip of size 25 x 3 mm ( 1 run ) ( only labour ) 27.1.18 copper strip of size 25 x 3 mm ( 1 run ) ( composite ) 27.1.19 copper strip of size 25 x 5 mm ( 1 run ) ( only supply ) 27.1.20 copper strip of size 25 x 5 mm ( 1 run ) ( only labour ) 27.1.21 copper strip of size 25 x 5 mm ( 1 run ) ( composite ) 27.1.22 copper strip of size 50 x 6 mm ( 1 run ) ( only supply ) 27.1.23 copper strip of size 50 x 6 mm ( 1 run ) ( only labour ) 27.1.24 copper strip of size 50 x 6 mm ( 1 run ) ( composite ) 27.2 gi earthing strip supplying & installation of tinned gi strip / bare gi wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continuty test etc & all as directed by engg. in charge. 27.2.1 gi strip size 25 x 3 mm ( 1 run ) ( only supply ) 27.2.2 gi strip size 25 x 3 mm ( 1 run ) ( only labour ) 27.2.3 gi strip size 25 x 3 mm ( 1 run ) ( compsite ) 27.2.4 gi strip size 25 x 5 mm ( 1 run ) ( only supply ) 27.2.5 gi strip size 25 x 5 mm ( 1 run ) ( only labour ) 27.2.6 gi strip size 25 x 5 mm ( 1 run ) ( compsite ) 27.2.7 gi wire 8 swg, ( 1 run ) ( only supply ) 27.2.8 gi wire 8 swg, ( 1 run ) ( only labour ) 27.2.9 gi wire 8 swg, ( 1 run ) ( composite ) 27.3 earting stations / pits 27.3.1 maintenance of earthing pits treated type with charcoal , salt , water as per standard practice. 27.3.2 tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like cole, charcoal, salt, brass nut bolts & washers, watering arrangements, gi pipe ( b class ) , concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. etc. ( 2 nos, of neutral earthing of t / f, 2 nos. for t / f body earthing & 2 nos. for panel earthing ) hot dipped gi earth plate electrode 600 x 600 x 6.3 mm earth station 2.5 mtr below the ground level same as above as per drawing & specifications complete with all required materials like coke / charcoal, salts , brass nut bolts & washers, watering arrangement, gu pipe ( b class ) concrete / brick chamber, heavy duty cast iron cover plate & excavation in ground, refilling & removing of excess earth within a radius of 500 mtr.etc. scope also includes dewatering, shoring, & consolidation etc. ( composite ) 27.4 air terminator / lightening arrestor 27.4.1 air terminator consisting of 75 to 100 mm dia & 6 mm thick tin copper sphere with 5 nos of spikes of 6 mm dia, 100 mm long, 19 mm dia 600 mm long tinned copper rod 150 mm dia 10 mm thickness tinned copper flange, 200 x 200 x 10 mm tinned brass plate gi grouting bolts / anchor fasteners etc. ( composite ) 28.1 cable jointing straight through jointing for 1.1 kv pvc insulated al / copper conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.1.1 3.5 x 10 sq. mm copper ( only supply ) 28.1.2 3.5 x 10 sq. mm copper ( only labour ) 28.1.3 3.5 x 10 sq. mm copper ( composite ) 28.1.4 3.5 x 16 sq. mm copper ( only supply ) 28.1.5 3.5 x 16 sq. mm copper ( only labour ) 28.1.6 3.5 x 16 sq. mm copper ( composite ) 28.1.7 3.5 x 25 sq. mm copper ( only supply ) 28.1.8 3.5 x 25 sq. mm copper ( only labour ) 28.1.9 3.5 x 25 sq. mm copper ( composite ) 28.1.10 3.5 x 35 sq. mm copper ( only supply ) 28.1.11 3.5 x 35 sq. mm copper ( only labour ) 28.1.12 3.5 x 35 sq. mm copper ( composite ) 28.1.13 3.5 x 50 sq. mm copper ( only supply ) 28.1.14 3.5 x 50 sq. mm copper ( only labour ) 28.1.15 3.5 x 50 sq. mm copper ( composite ) 28.1.16 3.5 x 70 sq. mm copper ( only supply ) 28.1.17 3.5 x 70 sq. mm copper ( only labour ) 28.1.18 3.5 x 70 sq. mm copper ( composite ) 28.1.19 3.5 x 95 sq. mm copper ( only supply ) 28.1.20 3.5 x 95 sq. mm copper ( only labour ) 28.1.21 3.5 x 95 sq. mm copper ( composite ) 28.1.22 3.5 x 120 sq. mm copper ( only supply ) 28.1.23 3.5 x 120 sq. mm copper ( only labour ) 28.1.24 3.5 x 120 sq. mm copper ( composite ) 28.1.25 3.5 x 150 sq. mm copper ( only supply ) 28.1.26 3.5 x 150 sq. mm copper ( only labour ) 28.1.27 3.5 x 150 sq. mm copper ( composite ) 28.1.28 3.5 x 185 sq. mm copper ( only supply ) 28.1.29 3.5 x 185 sq. mm copper ( only labour ) 28.1.30 3.5 x 185 sq. mm copper ( composite ) 28.1.31 3.5 x 240 sq. mm copper ( only supply ) 28.1.32 3.5 x 240 sq. mm copper ( only labour ) 28.1.33 3.5 x 240 sq. mm copper ( composite ) 28.1.34 3.5 x 300 sq. mm copper ( only supply ) 28.1.35 3.5 x 300 sq. mm copper ( only labour ) 28.1.36 3.5 x 300 sq. mm copper ( composite ) 28.1.37 3.5 x 400 sq. mm copper ( only supply ) 28.1.38 3.5 x 400 sq. mm copper ( only labour ) 28.1.39 3.5 x 400 sq. mm copper ( composite ) 28.2 straight through jointing for 11 / 33 kv xlpe insulated al conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.2.1 as described above, 11kv, 3 x 240 sq.mm xlpe ( only supply ) 28.2.2 as described above, 11kv, 3 x 240 sq.mm xlpe ( only labour ) 28.2.3 as described above, 11kv, 3 x 240 sq.mm xlpe ( composite ) 28.2.4 as described above, 33kv, 3 x 300 sq. mm xlpe ( only supply ) 28.2.5 as described above, 33kv, 3 x 300 sq. mm xlpe ( only labour ) 28.2.6 as described above, 33kv, 3 x 300 sq. mm xlpe ( composite ) 29.1 switch board for ac pointfabrication / & supply, installation. testing & commissioning of ms box made out of 16 / 14 swg ms sheet with removable top cover of 3 mm white hylam sheet / ms sheet with screws, cup washer etc. & complete concealed in wall with their following accessories mounted on it & their inter connection with 2.5 / 4 sq. mm pvc insulated copper cord wire. all as required & as directed by o i c, es. 29.1.1 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only supply ) 29.1.2 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only labour ) 29.1.3 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( composite ) 29.1.4 as per item no 29.1 but for 40 amps dp mcb & socket ( only supply ) 29.1.5 as per item no 29.1 but for 40 amps dp mcb & socket ( only labour ) 29.1.6 as per item no 29.1 but for 40 amps dp mcb & socket ( composite ) 29.1.7 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only supply ) 29.1.8 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only labour ) 29.1.9 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( composite ) 29.2 replacement for item no 29.1 29.2.1 replacement of 20 amps, reroll type metallic spn sockets ( only supply ) 29.2.2 replacement of 20 amps, reroll type metallic spn sockets ( only labour ) 29.2.3 replacement of 20 amps, reroll type metallic spn sockets ( composite ) 29.2.4 replacement of 32 amps, reroll type metallic spn sockets ( only supply ) 29.2.5 replacement of 32 amps, reroll type metallic spn sockets ( only labour ) 29.2.6 replacement of 32 amps, reroll type metallic spn sockets ( composite ) 29.2.7 replacement of 40 amps, reroll type metallic spn sockets ( only supply ) 29.2.8 replacement of 40 amps, reroll type metallic spn sockets ( only labour ) 29.2.9 replacement of 40 amps, reroll type metallic spn sockets ( composite ) 29.2.10 replacement of 63 amps, reroll type metallic spn sockets ( only supply ) 29.2.11 replacement of 63 amps, reroll type metallic spn sockets ( only labour ) 29.2.12 replacement of 63 amps, reroll type metallic spn sockets ( composite ) 29.2.13 supply & fixing metallic top for 10 amps 2p+e ( only supply ) 29.2.14 supply & fixing metallic top for 10 amps 2p+e ( only labour ) 29.2.15 supply & fixing metallic top for 10 amps 2p+e ( composite ) 29.2.16 as per item no 29.2.13 but for 20 amps ( only supply ) 29.2.17 as per item no 29.2.13 but for 20 amps ( only labour ) 29.2.18 as per item no 29.2.13 but for 20 amps ( composite ) 29.2.19 as per item no 29.2.13 but for 32 amps ( only supply ) 29.2.20 as per item no 29.2.13 but for 32 amps ( only labour ) 29.2.21 as per item no 29.2.13 but for 32 amps ( composite ) 29.2.22 as per item no 29.2.13 but for 40 amps ( only supply ) 29.2.23 as per item no 29.2.13 but for 40 amps ( only labour ) 29.2.24 as per item no 29.2.13 but for 40 amps ( composite ) 29.2.25 supplying & fixing metallic top 32 amps, 3 p + e ( only supply ) 29.2.26 supplying & fixing metallic top 32 amps, 3 p + e ( only labour ) 29.2.27 supplying & fixing metallic top 32 amps, 3 p + e ( composite ) 29.2.28 spike guard of approved make for computer ( only supply ) 29.2.29 heavy duty spike guard of approved make for equipments ( only supply ) 30.1 distribution boards providing & erecting distribution made out of 2 mm thick ( in case of fabrication ) ms crca sheet with concealed hinges, mounted on ms angle frame & grouted on the wall / fixed on the coloum with anchor fastener with earthing terminal, neutral link, interconnection with adequate size of bus bar / wires, interior of the db shall be covered with 3 mm thick frp sheet with necessary cut out, neoprene gasket, painting with seven tank metal treatment process ( shade to be got approved ) / powder coating all as per instructions of e i c, complete in all respect. 30.1.1.1 lighting distribution boardsall as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only supply ) 30.1.1.2 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only labour ) 30.1.1.3 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( composite ) 30.1.1.4 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only supply ) 30.1.1.5 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only labour ) 30.1.1.6 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( composite ) 30.1.2 power distribution boards 30.1.2.1 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only supply ) 30.1.2.2 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only labour ) 30.1.2.3 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( composite ) 30.1.2.4 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only supply ) 30.1.2.5 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only labour ) 30.1.2.6 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( composite ) 30.1.3 ready made distribution boards supply, erection, testing & commissioning of sheet metal powered coated distribution boards inclusive of mcbs with bus bar, neutral link & connection wire set etc of mds / siemens make confirming to ip 42. all as required & directed by o i c, es with prior approval. 30.1.3.1 spn 4 way ( only supply ) 30.1.3.2 spn 4 way ( only labour ) 30.1.3.3 spn 4 way ( composite ) 30.1.3.4 spn 6 way ( only supply ) 30.1.3.5 spn 6 way ( only labour ) 30.1.3.6 spn 6 way ( composite ) 30.1.3.7 spn 8 way ( only supply ) 30.1.3.8 spn 8 way ( only labour ) 30.1.3.9 spn 8 way ( composite ) 30.1.3.10 spn 12 way ( only supply ) 30.1.3.11 spn 12 way ( only labour ) 30.1.3.12 spn 12 way ( composite ) 30.1.3.13 tpn 4 way ( only supply ) 30.1.3.14 tpn 4 way ( only labour ) 30.1.3.15 tpn 4 way ( composite ) 30.1.3.16 tpn 6 way ( only supply ) 30.1.3.17 tpn 6 way ( only labour ) 30.1.3.18 tpn 6 way ( composite ) 30.1.3.19 tpn 8 way ( only supply ) 30.1.3.20 tpn 8 way ( only labour ) 30.1.3.21 tpn 8 way ( composite ) 30.1.3.22 tpn 12 way ( only supply ) 30.1.3.23 tpn 12 way ( only labour ) 30.1.3.24 tpn 12 way ( composite ) 30.1.4.1 aluminum anodized name plates for circuit identification with prior approval. ( only supply ) 30.1.4.2 aluminum anodized name plates for circuit identification with prior approval. ( only labour ) 30.1.4.3 aluminum anodized name plates for circuit identification with prior approval. ( only composite ) 31.1 pvc boardssupply, installation of suitable size of pvc board of approved make with necessary fixing arrangement doene by suitable screwing on any kind of surface for installing accessories like switches, sockets, regulators oe nay other similar application as per the instructions and as directed by e i c, es 31.1.1 4 x 4 ( only supply ) 31.1.2 4 x 4 ( only labour ) 31.1.3 4 x 4 ( composite ) 31.1.4 4 x 6 ( only supply ) 31.1.5 4 x 6 ( only labour ) 31.1.6 4 x 6 ( composite ) 31.1.7 4 x 7 ( only supply ) 31.1.8 4 x 7 ( only labour ) 31.1.9 4 x 7 ( composite ) 31.1.10 6 x 6 ( only supply ) 31.1.11 6 x 6 ( only labour ) 31.1.12 6 x 6 ( composite ) 31.1.13 6 x 8 ( only supply ) 31.1.14 6 x 8 ( only labour ) 31.1.15 6 x 8 ( composite ) 31.1.16 8 x 10 ( only supply ) 31.1.17 8 x 10 ( only labour ) 31.1.18 8 x 10 ( composite ) 31.1.19 10 x 12 ( only supply ) 31.1.20 10 x 12 ( only labour ) 31.1.21 10 x 12 ( composite ) 31.1.22 12 x 12 ( only supply ) 31.1.23 12 x 12 ( only labour ) 31.1.24 12 x 12 ( composite ) 31.1.25 3.5 x 6 ( only supply ) 31.1.26 3.5 x 6 ( only labour ) 31.1.27 3.5 x 6 ( composite ) 31.1.28 3.5 x 8 ( only supply ) 31.1.29 3.5 x 8 ( only labour ) 31.1.30 3.5 x 8 ( composite ) 31.1.31 3.5 x 10 ( only supply ) 31.1.32 3.5 x 10 ( only labour ) 31.1.33 3.5 x 10 ( composite ) 31.1.34 3.5 x 12 ( only supply ) 31.1.35 3.5 x 12 ( only labour ) 31.1.36 3.5 x 12 ( composite ) 32 mcbs / mccbs / sfus / isolators 32.1 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box & lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.1.1. as per item no 32.1 for– 32 a ( only supply ) 32.1.2 as per item no 32.1 for– 32 a ( only labour ) 32.1.3. as per item no 32.1 for– 32 a ( composite ) 32.1.4 as per item no 32.1 but for– 63 a ( only supply ) 32.1.5. as per item no 32.1 but for– 63 a ( only labour ) 32.1.6 as per item no 32.1 but for– 63 a ( composite ) 32.1.7. as per item no 32.1 but for– 100 a ( only supply ) 32.1.8 as per item no 32.1 but for– 100 a ( only labour ) 32.1.9 as per item no 32.1 but for– 100 a ( composite ) 32.1.10 as per item no 32.1 but for– 200 a ( only supply ) 32.1.11. as per item no 32.1 but for– 200 a ( only labour ) 32.1.12 as per item no 32.1 but for– 200 a ( composite ) 32.1.13 as per item no 32.1 but for 250 a ( only supply ) 32.1.14 as per item no 32.1 but for 250 a ( only labour ) 32.1.15 as per item no 32.1 but for 250 a ( composite ) 32.1.16 as per item no 32.1 but for 400 a ( only supply ) 32.1.17 as per item no 32.1 but for 400 a ( only labour ) 32.1.18 as per item no 32.1 but for 400 a ( composite ) 32.1.19 as per item no 32.1 but for 630 a ( only supply ) 32.1.20 as per item no 32.1 but for 630 a ( only labour ) 32.1.21 as per item no 32.1 but for 630 a ( composite ) 32.2 supply, fixing, testing & commissioning of c curve mcb with enclosure & connected with provided leads on incoming & outgoing side with all fixing arrangemet etc duly completed approved manner, all as per instruction and as directed by e i c, es. 32.2.1 as per item no 32.2 for– 6 a sp ( only supply ) 32.2.2 as per item no 32.2 for– 6 a sp ( only labour ) 32.2.3 as per item no 32.2 for– 6 a sp ( composite ) 32.2.4 as per item no 32.2 but for– 16 a sp ( only supply ) 32.2.5 as per item no 32.2 but for– 16 a sp ( only labour ) 32.2.6 as per item no 32.2 but for– 16 a sp ( composite ) 32.2.7 as per item no 32.2 but for– 20 a sp ( only supply ) 32.2.8 as per item no 32.2 but for– 20 a sp ( only labour ) 32.2.9 as per item no 32.2 but for– 20 a sp ( composite ) 32.2.10 as per item no 32.2 but for– 32 a sp ( only supply ) 32.2.11 as per item no 32.2 but for– 32 a sp ( only labour ) 32.2.12 as per item no 32.2 but for– 32 a sp ( composite ) 32.2.13 as per item no 32.2 but for– 20 a dp ( only supply ) 32.2.14 as per item no 32.2 but for– 20 a dp ( only labour ) 32.2.15 as per item no 32.2 but for– 20 a dp ( composite ) 32.2.16 as per item no 32.2 but for– 32 a dp ( only supply ) 32.2.17 as per item no 32.2 but for– 32 a dp ( only labour ) 32.2.18 as per item no 32.2 but for– 32 a dp ( composite ) 32.2.19 as per item no 32.2 but for– 40 a dp ( only supply ) 32.2.20 as per item no 32.2 but for– 40 a dp ( only labour ) 32.2.21 as per item no 32.2 but for– 40 a dp ( composite ) 32.2.22 as per item no 32.2 but for– 63 a dp ( only supply ) 32.2.23 as per item no 32.2 but for– 63 a dp ( only labour ) 32.2.24 as per item no 32.2 but for– 63 a dp ( composite ) 32.2.25 as per item no 32.2 but for– 32 a tp ( only supply ) 32.2.26 as per item no 32.2 but for– 32 a tp ( only labour ) 32.2.27 as per item no 32.2 but for– 32 a tp ( composite ) 32.2.28 as per item no 32.2 but for– 40 a tp ( only supply ) 32.2.29 as per item no 32.2 but for– 40 a tp ( only labour ) 32.2.30 as per item no 32.2 but for– 40 a tp ( composite ) 32.2.31 all as per item no 30.1 for 63 a tp ( only supply ) 32.2.32 as per item no 32.2 but for– 63 a tp ( only labour ) 32.2.33 as per item no 32.2 but for– 63 a tp ( composite ) 32.2.34 as per item no 32.2 but for32 a, 4 pole ( only supply ) 32.2.35 as per item no 32.2 but for32 a, 4 pole ( only labour ) 32.2.36 as per item no 32.2 but for32 a, 4 pole ( composite ) 32.2.37 as per item no 32.2 but for40 a, 4 pole ( only supply ) 32.2.38 as per item no 32.2 but for40 a, 4 pole ( only labour ) 32.2.39 as per item no 32.2 but for40 a, 4 pole ( composite ) 32.2.40 as per item no 32.2 but for63 a, 4 pole ( only supply ) 32.2.41 as per item no 32.2 but for63 a, 4 pole ( only labour ) 32.2.42 as per item no 32.2 but for63 a, 4 pole ( composite ) 32.2.43 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only supply ) 32.2.44 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only labour ) 32.2.45 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( composite ) 32.3 supply, fixing, testing & commissioning of tpn sfu in sheet steel enclosure of reputed make with suitable hrc fuses and to be connected with provided list with all necessary fixing arrangement as as per instrructions and as directed by e i c, es. 32.3.1 32 a, 415 v, ac ( only supply ) 32.3.2 32 a, 415 v, ac ( only labour ) 32.3.3 32 a, 415 v, ac ( composite ) 32.3.4 63 a, 415 v, ac ( only supply ) 32.3.5 63 a, 415 v, ac ( only labour ) 32.3.6 63 a, 415 v, ac ( composite ) 32.3.7 125 a, 415 v, ac ( only supply ) 32.3.8 125 a, 415 v, ac ( only labour ) 32.3.9 125 a, 415 v, ac ( composite ) 32.3.10 200 a, 415 v, ac ( only supply ) 32.3.11 200 a, 415 v, ac ( only labour ) 32.3.12 200 a, 415 v, ac ( composite ) 32.3.14 250 a, 415 v, ac ( only labour ) 32.3.15 250 a, 415 v, ac ( composite ) 32.3.16 315 a, 415 v, ac ( only supply ) 32.3.17 315 a, 415 v, ac ( only labour ) 32.3.18 315 a, 415 v, ac ( composite ) 32.3.19 400 a, 415 v, ac ( only supply ) 32.3.20 400 a, 415 v, ac ( only labour ) 32.3.21 400 a, 415 v, ac ( composite ) 32.3.22 630 a, 415 v, ac ( only supply ) 32.3.23 630 a, 415 v, ac ( only labour ) 32.3.24 630 a, 415 v, ac ( composite ) 32.4 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.4.1 as per item no 32.4 for 1000 a ( only supply ) 32.4.2 as per item no 32.4 for 1000 a ( only labour ) 32.4.3 as per item no 32.4 for 1000 a ( composite ) 32.4.4 as per item no 32.4 but for 800 a ( only supply ) 32.4.5 as per item no 32.4 but for 800 a ( only labour ) 32.4.6 as per item no 32.4 but for 800 a ( composite ) 32.5 providing, fixing, testing & commissioning of reputed make tpn isolator with provided leads incoming & outgoing side with all necessary fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.5.1 as per item no 32.5 for 400 a ( only supply ) 32.5.2 as per item no 32.5 for 400 a ( only labour ) 32.5.3 as per item no 32.5 for 400 a ( composite ) 32.5.4 as per item no 32.5 but for 250 a ( only supply ) 32.5.5 as per item no 32.5 but for 250 a ( only labour ) 32.5.6 as per item no 32.5 but for 250 a ( composite ) 32.5.7 as per item no 32.5 but for 125 a ( only supply ) 32.5.8 as per item no 32.5 but for 125 a ( only labour ) 32.5.9 as per item no 32.5 but for 125 a ( composite ) 32.5.10 as per item no 32.5 but for 63 a ( only supply ) 32.5.11 as per item no 32.5 but for 63 a ( only labour ) 32.5.12 as per item no 32.5 but for 63 a ( composite ) 32.6 providing, fixing, testing & commissioning of reputed make tpn sfu with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.6.1 as per item no 32.6 for 630 a ( only supply ) 32.6.2 as per item no 32.6 for 630 a ( only labour ) 32.6.3 as per item no 32.6 for 630 a ( composite ) 32.6.4 as per item no 32.6 but for 400 a ( only supply ) 32.6.5 as per item no 32.6 but for 400 a ( only labour ) 32.6.6 as per item no 32.6 but for 400 a ( composite ) 32.6.7 as per item no 32.6 but for 250 a ( only supply ) 32.6.8 as per item no 32.6 but for 250 a ( only labour ) 32.6.9 as per item no 32.6 but for 250 a ( composite ) 32.6.10 as per item no 32.6 but for 125 a ( only supply ) 32.6.11 as per item no 32.6 but for 125 a ( only labour ) 32.6.12 as per item no 32.6 but for 125 a ( composite ) 32.6.13 as per item no 32.6 but for 200 a ( only supply ) 32.6.14 as per item no 32.6 but for 200 a ( only labour ) 32.6.15 as per item no 32.6 but for 200 a ( composite ) 32.6.16 as per item no 32.6 but for 63 a ( only supply ) 32.6.17 as per item no 32.6 but for 63 a ( only labour ) 32.6.18 as per item no 32.6 but for 63 a ( composite ) 32.6.19 as per item no 32.6 but for 32 a ( only supply ) 32.6.20 as per item no 32.6 but for 32 a ( only labour ) 32.6.21 as per item no 32.6 but for 32 a ( composite ) 32.7 providing, fixing, testing & commissioning of reputed make tpn mcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner all asper instructions and as diredtec by e i c, es. 32.7.1 all as per item no 32.7 for 63 a ( only supply ) 32.7.2 all as per item no 32.7 for 63 a ( only labour ) 32.7.3 all as per item no 32.7 for 63 a ( composite ) 32.7.4 all as per item no 32.7 for 32 a ( only supply ) 32.7.5 all as per item no 32.7 for 32 a ( only labour ) 32.7.6 all as per item no 32.7 for 32 a ( composite ) 32.8 providing, fixing, testing & commissioning of reputed dp mcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.8.1 all as per item no 32.8 for 63 a ( only supply ) 32.8.2 all as per item no 32.8 for 63 a ( only labour ) 32.8.3 all as per item no 32.8 for 63 a ( composite ) 32.8.4 all as per item no 32.8 but for 40 a ( only supply ) 32.8.5 all as per item no 32.8 but for 40 a ( only labour ) 32.8.6 all as per item no 32.8 but for 40 a ( composite ) 32.8.7 all as per item no 32.8 but for 32 a ( only supply ) 32.8.8 all as per item no 32.8 but for 32 a ( only labour ) 32.8.9 all as per item no 32.8 but for 32 a ( composite ) 32.8.10 all as per item no 32.8 but for 20 a ( only supply ) 32.8.11 all as per item no 32.8 but for 20 a ( only labour ) 32.8.12 all as per item no 32.8 but for 20 a ( composite ) 32.8.13 all as per item no 32.8 but for 16 a ( only supply ) 32.8.14 all as per item no 32.8 but for 16 a ( only labour ) 32.8.15 all as per item no 32.8 but for 16 a ( composite ) 32.9 providing, fixing, testing & commissioning of reputed make dp elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es 32.9.1 all as per item no 32.9 for 63 a ( only supply ) 32.9.2 all as per item no 32.9 for 63 a ( only labour ) 32.9.3 all as per item no 32.9 for 63 a ( composite ) 32.9.4 all as per item no 32.9 but for 40 a ( only supply ) 32.9.5 all as per item no 32.9 but for 40 a ( only labour ) 32.9.6 all as per item no 32.9 but for 40 a ( composite ) 32.9.7 all as per item no 32.9 but for 25 a ( only supply ) 32.9.8 all as per item no 32.9 but for 25 a ( only labour ) 32.9.9 all as per item no 32.9 but for 25 a ( composite ) 32.10.a providing, fixing, testing & commissioning of reputed make 4 pole elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es. 32.10.1 all as per item no 32.10 for 63 a ( only supply ) 32.10.2 all as per item no 32.10 for 63 a ( only labour ) 32.10.3 all as per item no 32.10 for 63 a ( composite ) 32.10.4 all as per item no 32.10 but for 40 a ( only supply ) 32.10.5 all as per item no 32.10 but for 40 a ( only labour ) 32.10.6 all as per item no 32.10 but for 40 a ( composite ) 32.11 providing, fixing, testing & commissioning of reputed make sp mcb with provided leads on incoming & outgoing side with fixing arrangementduly completed in approved manner all as per instructions and as directed by e i c, es. 32.11.1 all as per item no 32.11 for 40 / 63a ( only supply ) 32.11.2 all as per item no 32.11 for 40 / 63a ( only labour ) 32.11.3 all as per item no 32.11 for 40 / 63a ( composite ) 32.11.4 all as per item no 32.11 but for 32 a ( only supply ) 32.11.5 all as per item no 32.11 but for 32 a ( only labour ) 32.11.6 all as per item no 32.11 but for 32 a ( composite ) 32.11.7 all as per item no 32.11 but for 20 a ( only supply ) 32.11.8 all as per item no 32.11 but for 20 a ( only labour ) 32.11.9 all as per item no 32.11 but for 20 a ( composite ) 32.11.10 all as per item no 32.11 but for 16 a ( only supply ) 32.11.11 all as per item no 32.11 but for 16 a ( only labour ) 32.11.12 all as per item no 32.11 but for 16 a ( composite ) 32.11.13 all as per item no 32.11 but for 6 a ( only supply ) 32.11.14 all as per item no 32.11 but for 6 a ( only labour ) 32.11.15 all as per item no 32.11 but for 6 a ( composite ) 32.12 providing, fixing, testing & commissioning of reputed make tpn mcb+elcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es 32.12.1 all as per item no 32.12 for 32 a ( only supply ) 33.1 ct / pt and other panel componentsproviding, fixing, testing & commissioning of reputed make ct with provided bus bar on incoming & leads on outgoing side duly completed in approved manner. class 1, 15 va, resin cast, bar primary type. 33.2 supply, fixing, testing and commissioning of various sizes of annunciator panel as mentioned below with test, accepts, reset push button, supply on indication with necessary fixing arrangement, all as per instructions and as directed by e i c, es. ( prior approval is required ) 33.3 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only supply ) 33.3.1 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only labour ) 33.3.2 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( composite ) 33.4 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only supply ) 33.4.1 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only labour ) 33.4.2 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only composite ) 33.5 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.5.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.5.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.6 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.6.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.6.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.7 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.7.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.7.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.8 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.8.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.8.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.9 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.9.1 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.9.2 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 33.10.a providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.10.1 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.10.2 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 34.1 panel accessories providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only supply ) 34.1.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only labour ) 34.1.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( composite ) 34.2.0 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only supply ) 34.2.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only labour ) 34.2.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg.scale mi type for various ct ratings. ( composite ) 34.2.3 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.4 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.5 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.2.6 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.7 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.8 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.3.a providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only supply ) 34.3.1 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only labour ) 34.3.2 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( composite ) 34.4 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only supply ) 34.4.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only labour ) 34.4.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( composite ) 34.5 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( only supply ) 34.5.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg.scale mi type for above said ct ratings. ( item no. 8. ) ( only labour ) 34.5.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( composite ) 34.6 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only supply ) 34.6.1 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only labour ) 34.6.2 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( composite ) 34.6.3 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.4 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps.. ( only labour ) 34.6.5 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( composite ) 34.6.6 providing, fixing, testing & commissioning of three phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.7 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( only labour ) 34.6.8 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( composite ) 34.7 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only supply ) 34.7.1 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only labour ) 34.7.2 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( composite ) 34.8 providing, fixing, testing & commissioning of analog pf meter ( only supply ) 34.8.1 providing, fixing, testing & commissioning of analog pf meter ( only labour ) 34.8.2 providing, fixing, testing & commissioning of analog pf meter ( composite ) 34.9 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only supply ) 34.9.1 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only labour ) 34.9.2 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( composite ) 34.10.a providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only supply ) 34.10.1 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only labour ) 34.10.2 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( composite ) 34.11 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only supply ) 34.11.1 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only labour ) 34.11.2 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( composite ) 34.12 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only supply ) 34.12.1 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only labour ) 34.12.2 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( composite ) 34.13 providing, fixing, testing & commissioning of auto / mannual selector switch ( only supply ) 34.13.1 providing, fixing, testing & commissioning of auto / mannual selector switch ( only labour ) 34.13.2 providing, fixing, testing & commissioning of auto / mannual selector switch ( only composite ) 34.14 providing, fixing, testing & commissioning of 2p2w rotary switch ( only supply ) 34.14.1 providing, fixing, testing & commissioning of 2p2w rotary switch ( only labour ) 34.14.2 providing, fixing, testing & commissioning of 2p2w rotary switch ( composite ) 34.15 providing, fixing, testing & commissioning of 3p3w rotary switch ( only supply ) 34.15.1 providing, fixing, testing & commissioning of 3p3w rotary switch ( only labour ) 34.15.2 providing, fixing, testing & commissioning of 3p3w rotary switch ( composite ) 34.16 providing, fixing, testing & commissioning of 1 way toggle switch ( only supply ) 34.16.1 providing, fixing, testing & commissioning of 1 way toggle switch ( only labour ) 34.16.2 providing, fixing, testing & commissioning of 1 way toggle switch ( composite ) 34.17 providing, fixing, testing & commissioning of 2 way toggle switch ( only supply ) 34.17.1 providing, fixing, testing & commissioning of 2 way toggle switch ( only labour ) 34.17.2 providing, fixing, testing & commissioning of 2 way toggle switch ( composite ) 34.18 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only supply ) 34.18.1 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only labour ) 34.18.2 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( composite ) 34.19 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only supply ) 34.19.1 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only labour ) 34.19.2 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( composite ) 34.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only supply ) 34.20.1 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only labour ) 34.20.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( composite ) 34.21 providing, fixing, testing & commissioning of indicating lamp, led type. 34.21.1 for red, orange, yellow, off white, green coloured led lamp ( only supply ) 34.21.2 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.3 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.4 as per item no 34.21 but for blue coluored led lamp ( only supply ) 34.21.5 as per item no 34.21 but for blue coluored led lamp ( only labour ) 34.21.6 as per item no 34.21 but for blue coluored led lamp ( composite ) 34.21.7 providing and fixing of centrifugal switch ( only supply ) 34.21.8 providing and fixing of centrifugal switch ( only labour ) 34.21.9 providing and fixing of centrifugal switch ( composite ) 34.22 providing, fixing, testing & commissioning of push buttons ( only supply ) 34.22.1 providing, fixing, testing & commissioning of push buttons ( only labour ) 34.22.2 providing, fixing, testing & commissioning of push buttons ( composite ) 34.23 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only supply ) 34.23.1 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only labour ) 34.23.2 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( composite ) 34.24 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230 v ac. ( only supply ) 34.24.1 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( only labour ) 34.24.2 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( composite ) 34.24.3 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only supply ) 34.24.4 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only labour ) 34.24.5 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( composite ) 34.24.6 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only supply ) 34.24.7 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only labour ) 34.24.8 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( composite ) 34.25 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only supply ) 34.25.1 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only labour ) 34.25.2 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( composite ) 34.26 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.26.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.26.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.27 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.27.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.27.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.28 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only supply ) 34.28.1 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only labour ) 34.28.2 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( composite ) 34.29 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only supply ) 34.29.1 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only labour ) 34.29.2 thermo stat for space heatre 240 v ac, 30 deg. to 90 deg. ( composite ) 34.30 supply and fixing of 240 v ac, hooter cands make ( only supply ) 34.30.1 supply and fixing of240 v ac, hooter cands make ( only labour ) 34.30.2 supply and fixing of240 v ac, hooter cands make ( composite ) 34.31 providing 33 kv resin cast type ct for 33 kv panel. ratio 600 / 5 5 5 amps.burdun 15 va, class 1 / 5p10 / ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 34.31.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 34.31.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 34.32 providing dc power pack with battery backup ( only supply ) 34.32.1 providing dc power pack with battery backup ( only labour ) 34.32.2 providing dc power pack with battery backup ( composite ) 35 electrical accessories supply, fixing, testing and commissioning of the following electrical accessories on the hylam sheet / modular plates / pvc board etc or as directed by wherever required including appropriate size of copper conductor of pvc wires interconnection using lugs, insulatin tape etc. in complete manner as directed by e i c, es with prior approval. procurement of these items shall be done in accordence with approved makes. approval shall be sought from e i c, es for other brand or make. in case of reeplacement, old / removed items shall be handed over to e i c, es as it is. agency has to supply material as per existing makes as site linke anchor / roma precision etc. 35.1.1 6 amp, , flush type s / w ( only supply ) 35.1.2 6 amp, , flush type s / w ( only labour ) 35.1.3 6 amp, , flush type s / w ( composite ) 35.1.4 6 amp, , 3 pin socket ( only supply ) 35.1.5 6 amp, , 3 pin socket ( only labour ) 35.1.6 6 amp, , 3 pin socket ( composite ) 35.1.7 16 amp, , switch ( only supply ) 35.1.8 16 amp, , switch ( only labour ) 35.1.9 16 amp, , switch ( composite ) 35.1.10 16 amp, , 3 pin socket ( only supply ) 35.1.11 16 amp, , 3 pin socket ( only labour ) 35.1.12 16 amp, , 3 pin socket ( composite ) 35.1.13 16 amp, , 5 pin socket ( only supply ) 35.1.14 16 amp, , 5 pin socket ( only labour ) 35.1.15 16 amp, , 5 pin socket ( composite ) 35.1.16 6 amp, top ( only supply ) 35.1.17 6 amp, top ( only labour ) 35.1.18 6 amp, top ( composite ) 35.1.19 16 amp, top ( only supply ) 35.1.20 16 amp, top ( only labour ) 35.1.21 16 amp, top ( composite ) 35.1.22 6 amp, two way switch , make precision ( only supply ) 35.1.23 6 amp, two way switch , make precision ( only labour ) 35.1.24 6 amp, two way switch , make precision ( composite ) 35.1.25 16 amp two way switch ( only supply ) 35.1.26 16 amp two way switch ( only labour ) 35.1.27 16 amp two way switch ( composite ) 35.1.28 16 amp, 5 pin, switch socket combination board ( only supply ) 35.1.29 16 amp, 5 pin, switch socket combination board ( only labour ) 35.1.30 16 amp, 5 pin, switch socket combination board ( composite ) 35.1.31 2x15a, 5pin, switch socket combination board ( only supply ) 35.1.32 2x15a, 5pin, switch socket combination board ( only labour ) 35.1.33 2x15a, 5pin, switch socket combination board ( composite ) 35.1.34 6 amp, bell push ( only supply ) , 35.1.35 6 amp, bell push ( only labour ) 35.1.36 6 amp, bell push ( composite ) 35.1.37 ceiling rose ( only supply ) 35.1.38 ceiling rose ( only labour ) 35.1.39 ceiling rose ( composite ) 35.1.40 angle holder ( only supply ) 35.1.41 angle holder ( only labour ) 35.1.42 angle holder ( composite ) 35.1.43 batten holder ( only supply ) 35.1.44 batten holder ( only labour ) 35.1.45 batten holder ( composite ) 35.1.46 bell with indication, reset push button ( only supply ) 35.1.47 bell with indication, reset push button ( only labour ) 35.1.48 bell with indication, reset push button ( composite ) 35.1.49 buzzer of any approved make ( only supply ) 35.1.50 buzzer of any approved make ( only labour ) 35.1.51 buzzer of any approved make ( composite ) 35.1.52 3 pin telephone socket, ( only supply ) 35.1.53 3 pin telephone socket, ( only labour ) 35.1.54 3 pin telephone socket, ( composite ) 35.1.55 telephone socket ( rj – 11 jack ) ( only supply ) 35.1.56 telephone socket ( rj – 11 jack ) ( only labour ) 35.1.57 telephone socket ( rj – 11 jack ) ( composite ) 35.1.58 rj 45 jack socket ( only supply ) 35.1.59 rj 45 jack socket ( only labour ) 35.1.60 rj 45 jack socket ( composite ) 35.1.61 rj 11 pin ( only supply ) 35.1.62 rj 11 pin ( only labour ) 35.1.63 rj 11 pin ( composite ) 35.1.64 rj 45 pin ( only supply ) 35.1.65 rj 45 pin ( only labour ) 35.1.66 rj 45 pin ( composite ) 35.1.67 telephone 3 pin plug top ( only supply ) 35.1.68 telephone 3 pin plug top ( only labour ) 35.1.69 telephone 3 pin plug top ( composite ) 35.1.70 tv socket ( only supply ) 35.1.71 tv socket ( only labour ) 35.1.72 tv socket ( composite ) 35.1.73 tv pin ( male+ female ) ( only supply ) 35.1.74 tv pin ( male+ female ) ( only labour ) 35.1.75 tv pin ( male+ female ) ( compositey ) 35.1.76 tv connector ( splitter ) 35.1.77 as per item no 35.1.76 for 2 way ( only supply ) 35.1.78 as per item no 35.1.76 for 2 way ( only labour ) 35.1.79 as per item no 35.1.76 for 2 way ( composite ) 35.1.80 as per item no 35.1.76 but for 3 way ( only supply ) 35.1.81 as per item no 35.1.76 but for 3 way ( only labour ) 35.1.82 as per item no 35.1.76 but for 3 way ( composite ) 35.1.83 as per item no 35.1.76 but for 4 way ( only supply ) 35.1.84 as per item no 35.1.76 but for 4 way ( only labour ) 35.1.85 as per item no 35.1.76 but for 4 way ( composite ) 35.1.86 tv cable gland for rj 11 ( only supply ) 35.1.87 tv cable gland for rj 11 ( only labour ) 35.1.88 tv cable gland for rj 11 ( composite ) 35.1.89 glass fuse, 2 a / 4a ( only supply ) 35.1.90 glass fuse, 2 a / 4a ( only labour. ) 35.1.91 glass fuse, 2 a / 4a ( composite ) 35.1.92 glass fuse 6a / 10 a ( only supply ) 35.1.93 glass fuse 6a / 10 a ( only labour ) 35.1.94 glass fuse 6a / 10 a ( composite ) 35.1.95 250 w, , ceiling fan regulator ( only supply ) 35.1.96 250 w, , ceiling fan regulator ( only labour ) 35.1.97 250 w, , ceiling fan regulator ( composite ) 35.1.98 300 w, , ceiling fan regulator ( only suppply ) 35.1.99 300 w, , ceiling fan regulator ( only labour ) 35.1.100 300 w, , ceiling fan regulator ( composite ) 35.1.101 750 w, , ceiling fan regulator ( only supply ) 35.1.102 750 w, , ceiling fan regulator ( only labur ) 35.1.103 750 w, , ceiling fan regulator ( composite ) 35.1.104 1000 w, , ceiling fan regulator ( only supply ) 35.1.105 1000 w, , ceiling fan regulator ( only labour ) 35.1.106 1000 w, ceiling fan regulator ( composite ) 35.1.107 iron connector flat / round ( only supply ) 35.1.108 iron connector flat / round ( only labour ) 35.1.109 iron connector flat / round ( composite ) 35.1.110 industrial alarm bell ( only supply ) 35.1.111 industrial alarm bell ( only labour ) 35.1.112 industrial alarm bell ( composite ) 35.1.113 25 amps, dp switch flush type with neon indication. ( only supply ) 35.1.114 25 amps, dp switch flush type with neon indication. ( only labour ) 35.1.115 25 amps, dp switch flush type with neon indication. ( composite ) 35.1.116 32 amps, dp switch flush type with neon indication ( only supply ) 35.1.117 32 amps, dp switch flush type with neon indication ( only labour ) 35.1.118 32 amps, dp switch flush type with neon indication ( composite ) 35.1.119 glass for halogen fittings. ( only supply ) 35.1.120 glass for halogen fittings. ( only labour ) 35.1.121 glass for halogen fittings. ( composite ) 35.1.122 speed regulator h 70 k ohm ( only supply ) 35.1.123 speed regulator h 70 k ohm ( only labour ) 35.1.124 speed regulator h 70 k ohm ( composite ) 35.1.125 regulator for hoods as per sample ) ( only supply ) 35.1.126 regulator for hoods as per sample ) ( only labour ) 35.1.127 regulator for hoods in as per sample ) ( composite ) 35.1.128 16 amp, switch with red indicator ( only supply ) 35.1.129 16 amp, switch with red indicator ( only labour ) 35.1.130 16 amp, switch with red indicator ( composite ) 35.1.131 16 amp, switch with red indicator ( only supply ) 35.1.132 16 amp, switch with red indicator ( only labour ) 35.1.133 16 amp, switch with red indicator ( composiet ) 35.1.134 carbon brush for mixers etc. ( all sizes ) ( only supply ) 35.1.135 carbon brush for mixers etc. ( all sizes ) ( only labour ) 35.1.136 carbon brush for mixers etc. ( all sizes ) ( composite ) 35.1.137 carbon brush used for special purpose m / c ( only supply ) 35.1.138 carbon brush used for special purpose m / c ( only labour ) 35.1.139 carbon brush used for special purpose m / c ( composite ) 35.2 modular accesseries for anchor roma , legrand , as per existing at site matching or equivalent. general guidelines are as per item no 35.1 35.2.1 6 amp, switch ( only supply ) 35.2.2 6 amp, switch ( only labour ) 35.2.3 6 amp, switch ( composite ) 35.2.4 16 amp, switch ( only supply ) 35.2.5 16 amp, switch ( only labour ) 35.2.6 16 amp, switch ( composite ) 35.2.7 6 amp, two way switch ( only supply ) 35.2.8 6 amp, two way switch ( only labour ) 35.2.9 6 amp, two way switch ( composite ) 35.2.10 10 / 16 amp , two –way switch ( only supply ) 35.2.11 10 / 16 amp , two –way switch ( only labour ) 35.2.12 10 / 16 amp , two –way switch ( composite ) 35.2.13 6 amp, socket ( only supply ) 35.2.14 6 amp, socket ( only labour ) 35.2.15 6 amp, socket ( composite ) 35.2.16 16 amp, 3 pin socket ( only supply ) 35.2.17 16 amp, 3 pin socket ( only labour ) 35.2.18 16 amp, 3 pin socket ( compoxite ) 35.2.19 16 amp, 5 pin socket ( only supply ) 35.2.20 16 amp, 5 pin socket ( only labour ) 35.2.21 16 amp, 5 pin socket ( composite ) 35.2.22 telephone socket ( rj 11 ) ( only supply ) 35.2.23 telephone socket ( rj 11 ) ( only labour ) 35.2.24 telephone socket ( rj 11 ) ( composite ) 35.2.25 fan dimmer , 400 / 600w ( 0nly supply ) 35.2.26 fan dimmer, 400 / 600w ( 0nly labour ) 35.2.27 fan dimmer, 400 / 600w ( composite ) 35.2.28 1 way tv socket ( only supply ) 35.2.29 1 way tv socket ( only labour ) 35.2.30 1 way tv socket ( composite ) 35.2.31 2 way tv socket ( only supply ) 35.2.32 2 way tv socket ( only labour. ) 35.2.33 2 way tv socket ( composite ) 35.2.34 6 amp, switch with indicator ( only supply ) 35.2.35 6 amp, switch with indicator ( only labour ) 35.2.36 6 amp, switch with indicator ( composite ) 35.2.37 bell push ( only supply ) 35.2.38 bell push ( only labour ) 35.2.39 bell push ( composite ) 35.2.40 fan dimmer , 1000w ( 0nly supply ) 35.2.41 fan dimmer, 1000w ( 0nly labour ) 35.2.42 fan dimmer, 1000w ( composite ) 35.2.43 blank plate ( 0nly supply ) 35.2.44 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly supply ) 35.2.45 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly labour ) 35.2.46 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( composite ) 35.2.47 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly supply ) 35.2.48 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly labour ) 35.2.49 16 to 32a dp mcb with modular box including face plate surface / conealed type ( composite ) 35.2.50 rj 45 data socket ( 0nly supply ) 35.2.51 rj 45 data socket ( 0nly labour ) 35.2.52 rj 45 data socket ( composite ) 35.3 surface ( pvc ) boxes for modular accessories 35.3.1 1 or 2 way ( only supply ) 35.3.2 1 or 2 way ( only labour ) 35.3.3 1 or 2 way ( composite ) 35.3.4 3 way ( only supply ) 35.3.5 3 way ( only labour ) 35.3.6 3 way ( composite ) 35.3.7 4 way ( only supply ) 35.3.8 4 way ( only labour ) 35.3.9 4 way ( composite ) 35.3.10 6 way ( only supply ) 35.3.11 6 way ( only labour ) 35.3.12 6 way ( composite ) 35.3.13 8 way ( only supply ) 35.3.14 8 way ( only labour ) 35.3.15 8 way ( composite ) 35.3.16 8 way vertical / rectangular ( only supply ) 35.3.17 8 way vertical / rectangular ( only labour ) 35.3.18 8 way vertical / rectangular ( composite ) 35.3.19 12 way ( only supply ) 35.3.20 12 way ( only labour ) 35.3.21 12 way ( composite ) 35.3.22 16 way ( only supply ) 35.3.23 16 way ( only labour ) 35.3.24 16 way ( composite ) 35.3.25 18 way ( only supply ) 35.3.26 18 way ( only labour ) 35.3.27 18 way ( composite ) 35.4 concealed ( ms ) boxes for modular accessories & general accessories 35.4.1 1 or 2 way ( only supply ) 35.4.2 1 or 2 way ( only labour ) 35.4.3 1 or 2 way ( composite ) 35.4.4 3 way ( only supply ) 35.4.5 3 way ( only labour ) 35.4.6 3 way ( composite ) 35.4.7 4 way ( only supply ) 35.4.8 4 way ( only labour ) 35.4.9 4 way ( composite ) 35.4.10 6 way ( only supply ) 35.4.11 6 way ( only labour ) 35.4.12 6 way ( composite ) 35.4.13 8 way ( only supply ) 35.4.14 8 way ( only labour ) 35.4.15 8 way ( composite ) 35.4.16 8 way vertical / rectangular ( only supply ) 35.4.17 8 way vertical / rectangular ( only labour ) 35.4.18 8 way vertical / rectangular ( composite ) 35.4.19 12 way ( only supply ) 35.4.20 12 way ( only labour ) 35.4.21 12 way ( composite ) 35.4.22 16 way ( only supply ) 35.4.23 16 way ( only labour ) 35.4.24 16 way ( composite ) 35.4.25 18 way ( only supply ) 35.4.26 18 way ( only labour ) 35.4.27 18 way ( composite ) 35.5 face plate for modular accessories 35.5.1 1 way ( only supply ) 35.5.2 1 way ( only labour ) 35.5.3 1 way ( composite ) 35.5.4 2 way ( only supply ) 35.5.5 2 way ( only labour ) 35.5.6 2 way ( composite ) 35.5.7 3 way ( only supply ) 35.5.8 3 way ( only labour ) 35.5.9 3 way ( composite ) 35.5.10 4 way ( only supply ) 35.5.11 4 way ( only labour ) 35.5.12 4 way ( composite ) 35.5.13 6 way ( only supply ) 35.5.14 6 way ( only labour ) 35.5.15 6 way ( composite ) 35.5.16 8 way ( only supply ) 35.5.17 8 way ( only labour ) 35.5.18 8 way ( composite ) 35.5.19 8 way vertical / rectangular ( only supply ) 35.5.20 8 way vertical / rectangular ( only labour ) 35.5.21 8 way vertical / rectangular ( composite ) 35.5.22 12 way ( only supply ) 35.5.23 12 way ( only labour ) 35.5.24 12 way ( composite ) 35.5.25 16 way with or with indicator ( only supply ) 35.5.26 16 way with or with indicator ( only labour ) 35.5.27 16 way with or with indicator ( composite ) 35.5.28 18 way ( only supply ) 35.5.29 18 way ( only labour ) 35.5.30 18 way ( composite ) 35.5.31 cord less bell ( only supply ) 35.6 mcb fixing channel ( only supply ) 35.6.1 mcb fixing channel ( only labour ) 35.6.2 mcb fixing channel ( composite ) 35.7 connector fixing channel ( cst channel ) ( only supply ) 35.7.1 connector fixing channel ( cst channel ) ( only labour ) 35.7.2 connector fixing channel ( cst channel ) ( composite ) 35.8 ht electrical tape ( strippex ) , 25 mm x .76 mm x 9.1 m , one roll, make stanvac ( only supply ) 35.9 supply / fixing of assorted accessories 35.9.1 6 amps, 3 pin multi plug connector ( only supply ) 35.9.2 6 amps, 3 pin multi plug connector ( only labour ) 35.9.3 6 amps, 3 pin multi plug connector ( composite ) 35.9.4 16 amps, multi plug connector ( only supply ) 35.9.5 16 amps, multi plug connector ( only labour ) 35.9.6 16 amps, multi plug connector ( composote ) 35.9.7 6a, supper adaptor pearl ( only supply ) 35.9.8 6a, supper adaptor pearl ( only labour ) 35.9.9 6a, supper adaptor pearl ( composite ) 35.9.10 1 way bed switch ( only supply ) 35.9.11 1 way bed switch ( only labour ) 35.9.12 1 way bed switch ( composite ) 35.9.13 adaptor ( only supply ) 35.9.14 adaptor ( only labour ) 35.9.15 adaptor ( composite ) 35.9.16 3 pin flexi cord 6 a, ( extension board ) ( only supply ) 35.9.17 16 a, flexi cord, ( extension board ) ( only supply ) 35.10.a supply / fixing of various gang boxes: 35.10.1 1 way ( only supply ) 35.10.2 1 way ( only labour ) 35.10.3 1 way ( composite ) 35.10.4 2 way ( only supply ) 35.10.5 2 way ( only labour ) 35.10.6 2 way ( composite ) 35.10.7 3 way ( only supply ) 35.10.8 3 way ( only labour ) 35.10.9 3 way ( composite ) 35.10.10 4 way ( only supply ) 35.10.11 4 way ( only labour ) 35.10.12 4 way ( composite ) 35.10.13 5 way ( only supply ) 35.10.14 5 way ( only labour ) 35.10.15 5 way ( composite ) 35.11 supply / fixing of various domestic gang boxes: 35.11.1 1 way ( only supply ) 35.11.2 1 way ( only labour ) 35.11.3 1 way ( composite ) 35.11.4 2 way ( only supply ) 35.11.5 2 way ( only labour ) 35.11.6 2 way ( composite ) 35.11.7 3 way ( only supply ) 35.11.8 3 way ( only labour ) 35.11.9 3 way ( composite ) 35.11.10 4 way ( only supply ) 35.11.11 4 way ( only labour ) 35.11.12 4 way ( composite ) 35.11.13 double domestic ( only supply ) 35.11.14 double domestic ( only labour ) 35.11.15 double domestic ( composite ) 35.11.16 water proof jb for mk switch ( to be used in icu ) ( only supply ) 35.11.17 water proof jb for mk switch ( to be used in icu ) ( only labour ) 35.11.18 water proof jb for mk switch ( to be used in icu ) ( composite ) 35.11.19 legrand make modular type door key switch with key fob ( only supply ) 35.11.20 legrand make modular type door key switch with key fob ( only labour ) 35.11.21 legrand make modular type door key switch with key fob ( composite ) 35.11.22 10a modular switch legrand ( only supply ) 35.11.23 10a modular switch legrand ( only labour ) 35.11.24 10a modular switch legrand ( composite ) 35.11.25 10a modular socket legrand ( only supply ) 35.11.26 10a modular socket legrand ( only labour ) 35.11.27 10a modular socket legrand ( composite ) 35.11.28 20a modular switch legrand ( only supply ) 35.11.29 20a modular switch legrand ( only labour ) 35.11.30 20a modular switch legrand ( composite ) 35.11.31 20a modular socket legrand ( only supply ) 35.11.32 20a modular socket legrand ( only labour ) 35.11.33 20a modular socket legrand ( composite ) 36.1 supplying & replacing the following spare of electrical motor starter controls etc. or whereever applicable with coil voltage 240 v / 440 v.all as per instructions and as directed by e i c, es. old items shall be returned to e i c, es as it is.air brake contactors 36.1.1 air brake contactor l & t make type ml1 or equivalent ( only supply ) 36.1.2 air brake contactor l & t make type ml1 or equivalent ( only labour ) 36.1.3 air brake contactor l & t make type ml1 or equivalent ( composite ) 36.1.4 ml 1.5 or equivalent ( only supply ) 36.1.5 ml 1.5 or equivalent ( only labour ) 36.1.6 ml 1.5 or equivalent ( composite ) 36.1.7 ml 2 or equivalent ( only supply ) 36.1.8 ml 2 or equivalent ( only labour ) 36.1.9 ml 2 or equivalent ( composite ) 36.1.10 ml 3 or equivalent ( only supply ) 36.1.11 ml 3 or equivalent ( only labour ) 36.1.12 ml 3 or equivalent ( composite ) 36.1.13 ml 4 or equivalent ( only supply ) 36.1.14 ml 4 or equivalent ( only labour ) 36.1.15 ml 4 or equivalent ( composite ) 36.1.16 ml 6 or equivalent ( only supply ) 36.1.17 ml 6 or equivalent ( only labour ) 36.1.18 ml 6 or equivalent ( composite ) 36.1.19 ml 10 or equivalent ( only supply ) 36.1.20 ml 10 or equivalent ( only labour ) 36.1.21 ml 10 or equivalent ( composite ) 36.1.22 ml 12 or equivalent ( only supply ) 36.1.23 ml 12 or equivalent ( only labour ) 36.1.24 ml 12 or equivalent ( composite ) 36.2 supply & replacement of following spare parts, kit for l & t or equivalent make power contactor. work is to be carried out as per instructions ans as per direction of e i c, es. old / remob ved items shall be returned to e i c, es as it is. 36.2.1 ml 1 or equivalent ( only supply ) 36.2.2 ml 1 or equivalent ( only labour ) 36.2.3 ml 1 or equivalent ( composite ) 36.2.4 ml 1.5 or equivalent ( only supply ) 36.2.5 ml 1.5 or equivalent ( only labour ) 36.2.6 ml 1.5 or equivalent ( composite ) 36.2.7 ml 2 or equivalent ( only supply ) 36.2.8 ml 2 or equivalent ( only labour ) 36.2.9 ml 2 or equivalent ( composite ) 36.2.10 ml 3 or equivalent ( only supply ) 36.2.11 ml 3 or equivalent ( only labour ) 36.2.12 ml 3 or equivalent ( composite ) 36.2.13 ml 4 or equivalent ( only supply ) 36.2.14 ml 4 or equivalent ( only labour ) 36.2.15 ml 4 or equivalent ( composite ) 36.2.16 ml 6 or equivalent ( only supply ) 36.2.17 ml 6 or equivalent ( only labour ) 36.2.18 ml 6 or equivalent ( composite ) 36.2.19 ml 10 or equivalent ( only supply ) 36.2.20 ml 10 or equivalent ( only labour ) 36.2.21 ml 10 or equivalent ( composite ) 36.2.22 ml 12 or equivalent ( only supply ) 36.2.23 ml 12 or equivalent ( only labour ) 36.2.24 ml 12 or equivalent ( composite ) 36.3 supply & fixing of hrc fuses as per instructions and as directed by e i c, es. old / removed item shall be returned to e i c, es. 36.3.1 1a to 6a ( only supply ) 36.3.2 1a to 6a ( only labour ) 36.3.3 1a to 6a ( composite ) 36.3.4 16a ( only supply ) 36.3.5 16a ( only labour ) 36.3.6 16a ( composite ) 36.3.7 32a ( only supply ) 36.3.8 32a ( only labour ) 36.3.9 32a ( composite ) 36.3.10 63a ( only supply ) 36.3.11 63a ( only labour ) 36.3.12 63a ( composite ) 36.3.13 100a ( only supply ) 36.3.14 100a ( only labour ) 36.3.15 100a ( composite ) 36.3.16 125a ( only supply ) 36.3.17 125a ( only labour ) 36.3.18 125a ( composite ) 36.3.19 160a ( only supply ) 36.3.20 160a ( only labour ) 36.3.21 160a ( composite ) 36.3.22 250a ( only supply ) 36.3.23 250a ( only labour ) 36.3.24 250a ( composite ) 36.3.25 315a ( only supply ) 36.3.26 315a ( only labour ) 36.3.27 315a ( composite ) 36.3.28 400a ( only supply ) 36.3.29 400a ( only labour ) 36.3.30 400a ( composite ) 36.3.31 630a ( only supply ) 36.3.32 630a ( only labour ) 36.3.33 630a ( composite ) 36.3.34 800 a ( only supply ) 36.3.35 800 a ( only labour ) 36.3.36 800 a ( composite ) 36.4 replacement of the following item make bakelite cut out complete fuse holder db mounted, all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.4.1 16 a ( only supply ) 36.4.2 16 a ( only labour ) 36.4.3 16 a ( composite ) 36.4.4 32 a ( only supply ) 36.4.5 32 a ( only labour ) 36.4.6 32 a ( composite ) 36.4.7 63 a ( only supply ) 36.4.8 63 a ( only labour ) 36.4.9 63 a ( composite ) 36.5 replacement of the kit kat fuse all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.5.1 1a delay fuse ( only supply ) 36.5.2 1.5 a delay fuse ( only supply ) 36.5.3 5 amps ( only supply ) 36.5.4 5 amps ( only labour ) 36.5.5 5 amps ( composite ) 36.5.6 10 amps ( only supply ) 36.5.7 10 amps ( only labour ) 36.5.8 10 amps ( composite ) 36.5.9 15 amps ( only supply ) 36.5.10 15 amps ( only labour ) 36.5.11 15 amps ( composite ) 36.6 replacement of the porcelain fuse ( base +top ) all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.6.1 5 amps ( only supply ) 36.6.2 5 amps ( only labour ) 36.6.3 5 amps ( composite ) 36.6.4 10 amps ( only supply ) 36.6.5 10 amps ( only labour ) 36.6.6 10 amps ( composite ) 36.6.7 25 amps ( only supply ) 36.6.8 25 amps ( only labour ) 36.6.9 25 amps ( composite ) 36.6.10 32 amps ( only supply ) 36.6.11 32 amps ( only labour ) 36.6.12 32 amps ( composite ) 36.7 replacement of the neutral link all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.7.1 16 a ( only supply ) 36.7.2 16 a ( only labour ) 36.7.3 16 a ( composite ) 36.7.4 32 a ( only supply ) 36.7.5 32 a ( only labour ) 36.7.6 32 a ( composite ) 36.7.7 63 a ( only supply ) 36.7.8 63 a ( only labour ) 36.7.9 63 a ( composite ) 36.8 replacement of elmex / connectwell connector block suitable for following cable sizes & reconnection of vided leads, all as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.8.1 1.5 sq. mm ( only supply ) 36.8.2 1.5 sq. mm ( only labour ) 36.8.3 1.5 sq. mm ( composite ) 36.8.4 2.5 sq. mm ( only supply ) 36.8.5 2.5 sq. mm ( only labour ) 36.8.6 2.5 sq. mm ( composite ) 36.8.7 4 sq. mm ( only supply ) 36.8.8 4 sq. mm ( only labour ) 36.8.9 4 sq. mm ( composite ) 36.8.10 6 sq. mm ( only supply ) 36.8.11 6 sq. mm ( only labour ) 36.8.12 6 sq. mm ( composite ) 36.8.13 10 sq. mm ( only supply ) 36.8.14 10 sq. mm ( only labour ) 36.8.15 10 sq. mm ( composite ) 36.8.16 16 sq. mm ( only supply ) 36.8.17 16 sq. mm ( only labour ) 36.8.18 16 sq. mm ( composite ) 36.8.19 25 sq. mm ( only supply ) 36.8.20 25 sq. mm ( only labour ) 36.8.21 25 sq. mm ( composite ) 36.8.22 35 sq. mm ( only supply ) 36.8.23 35 sq. mm ( only labour ) 36.8.24 35 sq. mm ( composite ) 36.8.25 50 sq. mm ( only supply ) 36.8.26 50 sq. mm ( only labour ) 36.8.27 50 sq. mm ( composite ) 36.8.28 70 sq. mm ( only supply ) 36.8.29 70 sq. mm ( only labour ) 36.8.30 70 sq. mm ( composite ) 36.8.31 95 sq. mm ( only supply ) 36.8.32 95 sq. mm ( only labour ) 36.8.33 95 sq. mm ( composite ) 36.8.34 120 sq. mm ( only supply ) 36.8.35 120 sq. mm ( only labour ) 36.8.36 120 sq. mm ( composite ) 36.8.37 ct shorting terminals ( only supply ) 36.8.38 ct shorting terminals ( only labour ) 36.8.39 ct shorting terminals ( composite ) 36.9 supply / replacement of terminal strips / blocks for varios types of motors etc as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.9.1 motors up to 10 hp ( only supply ) 36.9.2 motors up to 10 hp ( only labour ) 36.9.3 motors up to 10 hp ( composite ) 36.9.4 motors up to 20 hp ( only supply ) 36.9.5 motors up to 20 hp ( only labour ) 36.9.6 motors up to 20 hp ( composite ) 36.9.7 motors up to 30 hp ( only supply ) 36.9.8 motors up to 30 hp ( only labour ) 36.9.9 motors up to 30 hp ( composite ) 36.9.10 motors up to 40 hp ( only supply ) 36.9.11 motors up to 40 hp ( only labour ) 36.9.12 motors up to 40 hp ( composite ) 36.9.13 motors up to 50 hp ( only supply ) 36.9.14 motors up to 50 hp ( only labour ) 36.9.15 motors up to 50 hp ( composite ) 36.9.16 motors up to 60 hp ( only supply ) 36.9.17 motors up to 60 hp ( only labour ) 36.9.18 motors up to 60 hp ( composite ) 37.1 .ms sheet for boxes etc ms sheet for 16 swg to be used for fabrication of boxes, panels, cable and boxes etc. including cutting, bending, drilling, welding, riveting etc & painting with red oxide lead paint & two coats of enamel paint all as per instructions and as directed by e i c, es. 37.1.1 as per item no 37.1 for 14 swg ( only supply ) 37.1.2 as per item no 37.1 for 14 swg ( only labour ) 37.1.3 as per item no 37.1 for 14 swg ( composite ) 37.1.4 as per item no 37.1 for but for 16 swg ( only supply ) 37.1.5 as per item no 37.1 for but for 16 swg ( only labour ) 37.1.6 sas per item no 37.1 for but for 16 swg ( composite ) 37.1.7 as per item no 37.1 for but for 18 swg ( only supply ) 37.1.8 as per item no 37.1 for but for 18 swg ( only labour ) 37.1.9 as per item no 37.1 for but for 18 swg ( composite ) 37.2 supply, fabrication & installation of ms angle / strip / plate / rod / channel etc. as per given design duly painted with 2 coats of red oxide & 2 coats of enamel paint of approved shade all as per the instruction of eic. ( composite ) 37.3 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.3.1 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.3.2 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.4 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.4.1 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.4.2 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.5 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only supply ) 37.5.1 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only labour ) 37.5.2 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( composite ) 38.1 timers for starters / preventers supply, fixing & testing of on delay timer 0 to 60 sec. ( only supply ) 38.2 supply, fixing & testing of on delay timer 0 to 60 sec. ( only labour ) 38.3 supply, fixing & testing of on delay timer 0 to 60 sec. ( composite ) 38.4 supply, fixing & testing of off delay timer ( only supply ) 38.5 supply, fixing & testing of off delay timer ( only labour ) 38.6 supply, fixing & testing of off delay timer ( composite ) 38.7 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( only supply ) 38.8 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 38.9 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( composite ) 39 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.1 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.2 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( composite ) 39.3 single phase preventer type mpr1 ( only supply ) 39.4 single phase preventer type mpr1 ( only labour ) 39.5 single phase preventer type mpr1 ( composite ) 39.6 supply, fixing & testing of 0 24 hrs set digital timer ( only supply ) 39.7 supply, fixing & testing of 0 24 hrs set digital timer ( only labour ) 39.8 supply, fixing & testing of 0 24 hrs set digital timer ( composit ) 40.1 supply, installation & testing of app type capacitors / apfc relays, 440 v, 50 hz, all as per instructions ans as directed by e i c, es old / removed items shall be returned to e i c, es as it is. 25 kvar ( only supply ) 40.2 25 kvar ( only labour ) 40.3 25 kvar ( composite ) 40.4 50 kvar ( only supply ) 40.5 50 kvar ( only labour ) 40.6 50 kvar ( composite ) 40.7 100 kvar ( only supply ) 40.8 100 kvar ( only labour ) 40.9 100 kvar ( composite ) 40.10.a supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only supply ) 40.11 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only labour ) 40.12 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( composite ) 40.13 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only supply ) 40.14 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only labour ) 40.15 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( composite ) 41.1 fittings & fixtures supply / replacement, installation, testing & commissioning of following various fixtures & fittings complete with fluorescent tube / incandescent lamp / pl s lamp or any other suitale lamp etc. on surface of slab / beam / wall by means of brackets made out of 25 x 3 mm strip & 2 nos. of 6 mm anchor fastener / suspended from slab / beam by means of 19 mm dia. conduit pipe, ball & socket arrangement flexible 2 core 40 / 30 size cable / wire connection etc.or by means of suitable fixing arrangement, complete in all respect & as per instruction of engg. in charge & with prior approval by presenting sample fitting. make:philips / crompton / ge / wipro / orient or equivalent. in case of replacement old / removed items shall be reuturned to e i c, es as it is. 1 x 40 w rail ( box ) type fluorescent fitting ( only supply ) 41.2 1 x 40 w rail ( box ) type fluorescent fitting ( only labour ) 41.3 1 x 40 w rail ( box ) type fluorescent fitting ( composite ) 41.4 2 x 40 w rail type fluorescent ( only supply ) 41.5 2 x 40 w rail type fluorescent ( only labour ) 41.6 2 x 40 w rail type fluorescent ( composite ) 41.7 2 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.8 2 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.9 2 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.10.a 1 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.11 1 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.12.a 1 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.13 2 x 40 w industrial type fluorescent fitting ( only supply ) 41.14 2 x 40 w industrial type fluorescent fitting ( only labour ) 41.15 2 x 40 w industrial type fluorescent fitting ( composite ) 41.16 2 x 9 w pl s decorative recess type fitting. ( only supply ) 41.17.a 2 x 9 w pl s decorative recess type fitting. ( only labour ) 41.18 2 x 9 w pl s decorative recess type fitting. ( composite ) 41.19 2 x 11 w decorative surface type fitting ( only supply ) 41.20.a 2 x 11 w decorative surface type fitting ( only labour ) 41.21 2 x 11 w decorative surface type fitting ( composite ) 41.22 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only supply ) 41.23 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only labour ) 41.24 1 x 40 w decorative mirror optic fluorescent fitting surface type ( composite ) 41.25 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only supply ) 41.26 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only labour ) 41.27 2 x 40 w decorative mirror optic fluoresce fitting surface type ( composite ) 41.28 bulkhead fitting suitable for pl – s 9 w lamp ( only supply ) 41.29 bulkhead fitting suitable for pl – s 9 w lamp ( only labour ) 41.30.a bulkhead fitting suitable for pl – s 9 w lamp ( composite ) 41.31 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only supply ) 41.32 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only labour ) 41.33 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( composite ) 41.34 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.35 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.36 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.37 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.38 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.39 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.40.a 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only supply ) 41.41 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only labour ) 41.42 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( composite ) 41.43 decorative incandescent fixtures for red indication lamp ( only supply ) 41.44 decorative incandescent fixtures for red indication lamp ( only labour ) 41.45 decorative incandescent fixtures for red indication lamp ( composite ) 41.46 decorative incandescent fixtures with 75 w comptalux lamp ( only supply ) 41.47 decorative incandescent fixtures with 75 w comptalux lamp ( only labour ) 41.48 decorative incandescent fixtures with 75 w comptalux lamp ( composite ) 41.49 decorative incandescent fixtures for lecture hall [ 100w ] ( ( only supply ) 41.50.a decorative incandescent fixtures for lecture hall [ 100w ] ( ( only labour ) 41.51 decorative incandescent fixtures for lecture hall [ 100w ] ( ( composite ) 41.52 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only supply ) 41.53 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only labour ) 41.54 1 x 9 w decorative wall mounted fixtures with electronic ballast ( composite ) 41.55 2 x 9 w decorative fixtures for ( entrance canopy ) ( only supply ) 41.56 2 x 9 w decorative fixtures for ( entrance canopy ) ( only labour ) 41.57 2 x 9 w decorative fixtures for ( entrance canopy ) ( composite ) 41.58 2 x 25 w exit light fixture ( only supply ) 41.59 2 x 25 w exit light fixture ( only labour ) 41.60.a 2 x 25 w exit light fixture ( composite ) 41.61 2 x 18 w fluorescent industrial fitting for fume hood ( only supply ) 41.62 2 x 18 w fluorescent industrial fitting for fume hood ( only labour ) 41.63 2 x 18 w fluorescent industrial fitting for fume hood ( composite ) 41.64 1 x 9 w decorative surface fitting for wash basin mirror ( only supply ) 41.65 1 x 9 w decorative surface fitting for wash basin mirror ( only labour ) 41.66 1 x 9 w decorative surface fitting for wash basin mirror ( composite ) 41.67 night lamp fixture 15 w ( only supply ) 41.68 night lamp fixture 15 w ( only labour ) 41.69 night lamp fixture 15 w ( composite ) 41.70.a halogen lamp fitting. 41.70.1 suitable for 500 w ( only supply ) 41.70.2 suitable for 500 w ( only labour ) 41.70.3 suitable for 500 w ( composite ) 41.70.4 suitable for 1000 w ( only supply ) 41.70.5 suitable for 1000 w ( only labour ) 41.70.6 suitable for 1000 w ( composite ) 41.71 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only supply ) 41.72 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only labour ) 41.73 decorative incandescent fixture with 60 w / 75 w reflector lamp ( composite ) 41.74 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only supply ) 41.75 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only labour ) 41.76 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( composite ) 41.77 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only supply ) 41.78 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only labour ) 41.79 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( composite ) 41.80.a recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only supply ) 41.81 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only labour ) 41.82 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( composite ) 41.83 floor washer ( only supply ) 41.84 floor washer ( only labour ) 41.85 floor washer ( composite ) 41.86 turbolite with 6 cell reflector ( only supply ) 41.87 turbolite with 6 cell reflector ( only labour ) 41.88 turbolite with 6 cell reflector ( composite ) 41.89 solaris down lighter ( only supply ) 41.90.a solaris down lighter ( only labour ) 41.91 solaris down lighter ( composite ) 41.92 moisture proof halogen recessed fixture ( only supply ) 41.93 moisture proof halogen recessed fixture ( only labour ) 41.94 moisture proof halogen recessed fixture ( composite ) 41.95 gemini baflux max 2x 18 w plc lamp ( only supply ) 41.96 gemini baflux max 2x 18 w plc lamp ( only labour ) 41.97 gemini baflux max 2x 18 w plc lamp ( composite ) 41.98 rivia mini with 1 plc 10w ( only supply ) 41.99 rivia mini with 1 plc 10w ( only labour ) 41.100.a rivia mini with 1 plc 10w ( composite ) 41.101 emergency tube light fixture suitable to fix 9w pl lamp, ( only supply ) 41.102 emergency tube light fixture suitable to fix 9w pl lamp, ( only labour ) 41.103 emergency tube light fixture suitable to fix 9w pl lamp, ( composite ) 41.104 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only supply ) 41.105 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only labour ) 41.106 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( composite ) 41.107 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only supply ) 41.108 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only labour ) 41.109 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( composite ) 41.110.a dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only supply ) 41.111 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only labour ) 41.112 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( composite ) 41.113 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only supply ) 41.114 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only labour ) 41.115 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( composite ) 41.116 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.117 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.118 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.119 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.120.a fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.121 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.122 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only supply ) 41.123 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only labour ) 41.124 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( composite ) 41.125 2 x 36w pll fixture ( only supply ) 41.126 2 x 36w pll fixture ( only labour ) 41.127 2 x 36w pll fixture ( composite ) 41.128 25w, plc, lighting fixture ( only supply ) 41.129 25w, plc, lighting fixture ( only labour ) 41.130.a 25w, plc, lighting fixture ( composite ) 41.131 1x28w, energy efficient box type fitting ( only supply ) 41.132 1x28w, energy efficient box type fitting ( only labour ) 41.133 1x28w, energy efficient box type fitting ( composite ) 41.134 25w, plc lighting fixture ( only supply ) 41.135 25w, plc lighting fixture ( only labour ) 41.136 25w, plc lighting fixture ( composite ) 41.137 led light fixtures 6w recessed mounted led lighting fixture ( only supply ) 41.138 6w recessed mounted led lighting fixture ( only labour ) 41.139 6w recessed mounted led lighting fixture ( composite ) 41.140.a 9w recessed mounted led lighting fixture ( only supply ) 41.141 9w recessed mounted led lighting fixture ( only labour ) 41.142 9w recessed mounted led lighting fixture ( composite ) 41.143 12w recessed mounted led lighting fixture ( only supply ) 41.144 12w recessed mounted led lighting fixture ( only labour ) 41.145 12w recessed mounted led lighting fixture ( composite ) 41.146 15w recessed mounted led lighting fixture ( only supply ) 41.147 15w recessed mounted led lighting fixture ( only labour ) 41.148 15w recessed mounted led lighting fixture ( composite ) 41.149 18w recessed mounted led lighting fixture ( only supply ) 41.150.a 18w recessed mounted led lighting fixture ( only labour ) 41.151 18w recessed mounted led lighting fixture ( composite ) 41.152 24w recessed mounted led lighting fixture ( only supply ) 41.153 24w recessed mounted led lighting fixture ( only labour ) 41.154 24w recessed mounted led lighting fixture ( composite ) 41.155 3w recessed led type halogen lighting fixture ( only supply ) 41.156 3w recessed led type halogen lighting fixture ( only labour ) 41.157 3w recessed led type halogen lighting fixture ( composite ) 41.158 6w recessed led type halogen lighting fixture ( only supply ) 41.159 6w recessed led type halogen lighting fixture ( only labour ) 41.160.a 6w recessed led type halogen lighting fixture ( composite ) 41.161 9w recessed led type halogen lighting fixture ( only supply ) 41.162 9w recessed led type halogen lighting fixture ( only labour ) 41.163 9w recessed led type halogen lighting fixture ( composite ) 41.164 36w, 2x2 size recessed led lighting fixture ( only supply ) 41.165 36w, 2x2 size recessed led lighting fixture ( only labour ) 41.166 36w, 2x2 size recessed led lighting fixture ( composite ) 41.167 42w, 2x2 size recessed led lighting fixture ( only supply ) 41.168 42w, 2x2 size recessed led lighting fixture ( only labour ) 41.169 42w, 2x2 size recessed led lighting fixture ( composite ) 41.170 32w, 4 long fully diffused recessed led lighting fixture ( only supply ) 41.171 32w, 4 long fully diffused recessed led lighting fixture ( only labour ) 41.172 32w, 4 long fully diffused recessed led lighting fixture ( composite ) 41.173 6w surface mounted led lighting fixture ( only supply ) 41.174 6w surface mounted led lighting fixture ( only labour ) 41.175 6w surface mounted led lighting fixture ( composite ) 41.176 9w surface mounted led lighting fixture ( only supply ) 41.177 9w surface mounted led lighting fixture ( only labour ) 41.178 9w surface mounted led lighting fixture ( composite ) 41.179 12w surface mounted led lighting fixture ( only supply ) 41.180 12w surface mounted led lighting fixture ( only labour ) 41.181 12w surface mounted led lighting fixture ( composite ) 41.182 15w surface mounted led lighting fixture ( only supply ) 41.183 15w surface mounted led lighting fixture ( only labour ) 41.184 15w surface mounted led lighting fixture ( composite ) 41.185 18w surface mounted led lighting fixture ( only supply ) 41.186 18w surface mounted led lighting fixture ( only labour ) 41.187 18w surface mounted led lighting fixture ( composite ) 41.188 24w surface type led lighting fixture ( only supply ) 41.189 24w surface type led lighting fixture ( only labour ) 41.190 24w surface type led lighting fixture ( composite ) 41.191 22w, 4 long surface type led lighting fixture ( only supply ) 41.192 22w, 4 long surface type led lighting fixture ( only labour ) 41.193 22w, 4 long surface type led lighting fixture ( composite ) 41.194 8w, 2 long surface type led lighting fixture ( only supply ) 41.195 8w, 2 long surface type led lighting fixture ( only labour ) 41.196 8w, 2 long surface type led lighting fixture ( composite ) 41.197 32w, 4 long fully diffused surface led lighting fixture ( only supply ) 41.198 32w, 4 long fully diffused surface led lighting fixture ( only labour ) 41.199 32w, 4 long fully diffused surface led lighting fixture ( composite ) 41.200 22w, 4 long led tube ( only supply ) with one year warranty 41.201 22w, 4 long led tube ( only labour ) 41.202 22w, 4 long led tube ( only composite ) 42 providing, fixing & commissioning of ceiling fan white / brown colour as per requirement including down rod, double ball baring etc all as per instructions and as directed by e i c, es. in case of replacement old / removed item shall be returned to e i c, es as it is. 42.1 size 1400 mm sweep ( only supply ) 42.2 size 1400 mm sweep ( only labour ) 42.3 size 1400 mm sweep ( composite ) 42.4 size 1200 mm sweep ( only supply ) 42.5 size 1200 mm sweep ( only labour ) 42.6 size 1200 mm sweep ( composite ) 42.7 size 900 mm sweep ( only supply ) 42.8 size 900 mm sweep ( only labour ) 42.9 size 900 mm sweep ( composite ) 42.10.a same as per item no 42 but for wall mounted fan 42.10.1 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only supply ) 42.10.2 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only labour ) 42.10.3 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( composite ) 42.11 same as per item no 42 but for pedestal mounted fan 42.11.1 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.2 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.3 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( composite ) 42.11.4 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.5 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.6 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( composite ) 43 providing & erecting 1 phase or exhaust fan metal body with ms frame & gravity louvers, 1400 rpm, 230 v, 50 hz, all as per instructions and as directed by e i c, es. in case of replacement old / removed items shall be returned to e i c, es. 43.1.a 150 mm ( only supply ) 43.2 150 mm ( only labour ) 43.3 150 mm ( composite ) 43.4 200 mm ( only supply ) 43.5 200 mm ( only labour ) 43.6 200 mm ( composite ) 43.7 225 mm ( only supply ) 43.8 225 mm ( only labour ) 43.9 225 mm ( composite ) 43.10 300 mm ( only supply ) 43.11 300 mm ( only labour ) 43.12 300 mm ( composite ) 43.13 375 mm ( only supply ) 43.14 375 mm ( only labour ) 43.15 375 mm ( composite ) 43.16 450 mm ( only supply ) 43.17 450 mm ( only labour ) 43.18 450 mm ( composite ) street lighting supply / replacement, testing & commissioning of external terminal box of size 200 x 250 x 150 mm made of 4 mm thick cast iron / pvc, neatly painted complete with front operable door with allen key locking arrangement, arrangement for gland entry, water proof gasket, 4 nos. of 8 mm dia. 40 mm long brass terminals on 150 x 30 x 10 mm bakelite strip, 16 a hrc fuse base & carrier with 6 a hrc fuse / 16a sp mcb, 16 a neutral link, nipple or sleeve of external dia. 38 mm which can be inserted in 38 mm dia. gi pipe, all as directed by o i c, es. equvilent arrangement can be done only after prior approval for make as well as other releted fixing / control gear arrangement. in case of replacement old / removed item shall be returned to e i c, es. led street light fitting of following ratings having pressure die cast aluminimum housing with coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint , suitable to following features. luminaires suitable with base plate and fitted on a existing site pole. in built electronic led driver, high transmisivity diffuser>85%, ip 65 / 67 high efficacy, provide uniform low glare lighting , cri 70, warm white operating temperature: 40 to +60 celsius degree operatable voltage 220 240 v, 50 hz, pf>0.9, 44.1.1 70 / 85w cfl lamp fitting ( only supply ) 44.1.2 70 / 85w cfl lamp fitting ( only labour ) 44.1.3 70 / 85w cfl lamp fitting ( composite ) 44.1.4 9 / 11w, 12v, 75 ah solar stree light fitting ( only supply ) 44.1.5 9 / 11w, 12v, 75 ah solar stree light fitting ( only labour ) 44.1.6 9 / 11w, 12v, 75 ah solar stree light fitting ( composite ) 44.1.7 led street lights 20w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.8 20w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.9 20w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.10 25w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.11 25w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.12 25w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.13 35w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.14 35w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.15 35w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.16 60w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.17 60w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.18 60w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.19 70w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.20 70w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.21 70w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.22 90w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.23 90w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.24 90w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.25 120w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.26 120w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.27 120w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.28 20w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.29 20w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.30 20w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.31 30w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.32 30w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.33 30w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.34 50w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.35 50w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.36 50w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.37 80w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.38 80w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.39 80w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.40 100w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.41 100w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.42 100w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.43 120w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.44 120w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.45 120w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.46 150w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.47 150w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.48 150w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.49 200w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.50 200w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.51 200w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.52 30w, led dom light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.53 30w, led dom light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.54 30w, led dom light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.55 led street light drivers20w, led street light driver ( only supply ) 44.1.56 20w, led street light driver ( only labour ) 44.1.57 20w, led street light driver ( composite ) 44.1.58 25w, led street light driver ( only supply ) 44.1.59 25w, led street light driver ( only labour ) 44.1.60 25w, led street light driver ( composite ) 44.1.61 30 / 40w, led street light driver ( only supply ) 44.1.62 30 / 40w, led street light driver ( only labour ) 44.1.63 30 / 40w, led street light driver ( composite ) 44.1.64 60w, led street light driver ( only supply ) 44.1.65 60w, led street light driver ( only labour ) 44.1.66 60w, led street light driver ( composite ) 44.1.67 70w, led street light driver ( only supply ) 44.1.68 70w, led street light driver ( only labour ) 44.1.69 70w, led street light driver ( composite ) 44.1.70 90w, led street light driver ( only supply ) 44.1.71 90w, led street light driver ( only labour ) 44.1.72 90w, led street light driver ( composite ) 44.1.73 120w, led street light driver ( only supply ) 44.1.74 120w, led street light driver ( only labour ) 44.1.75 120w, led street light driver ( composite ) 44.1.76 150w, led street light driver ( only supply ) 44.1.77 150w, led street light driver ( only labour ) 44.1.78 150w, led street light driver ( composite ) 44.1.79 200w, led street light driver ( only supply ) 44.1.80 200w, led street light driver ( only labour ) 44.1.81 200w, led street light driver ( composite ) 44.2 street light pole erection 44.2.1 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 44.2.2 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 44.2.3 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable to 4cx16 sqmm size ( composite ) . 44.2.4 same as item no. 44.3.3 but with double arm brackets ( only supply ) . 44.2.5 same as item no. 44.3.3 but with double arm brackets ( only labour ) . 44.2.6 same as item no. 44.3.3 but with double arm brackets ( composite ) . 44.2.7 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . casting of new foundation for 7 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . casting of new foundation for 3 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . lamp holders 44.4 lamp holders 44.4.1 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only supply ) 44.4.2 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only labour ) 44.4.3 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( composite ) 44.6.25 supply & fixing of 70w cfl lamp reputed make ( only supply ) 44.6.26 supply & fixing of 70w cfl lamp reputed make ( only labour ) 44.6.27 supply & fixing of 70w cfl lamp reputed make ( composite ) 44.6.28 supply & fixing of 65w cfl lamp reputed make ( only supply ) 44.6.29 supply & fixing of 65w cfl lamp reputed make ( only labour ) 44.6.30 supply & fixing of 65w cfl lamp reputed make ( composite ) 44.6.31 supply & fixing of 85w cfl lamp reputed make ( only supply ) 44.6.32 supply & fixing of 85w cfl lamp reputed make ( only labour ) 44.6.33 supply & fixing of 85w cfl lamp reputed make ( composite ) 44.6.34 supply & fixing of 35w cfl lamp reputed make ( only supply ) 44.6.35 supply & fixing of 35w cfl lamp reputed make ( only labour ) 44.6.36 supply & fixing of 35w cfl lamp reputed make ( composite ) 45.1 telephone system all general guidelines will be as per any kind of point wiring. telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only supply ) 45.2 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only labour ) 45.3 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( composite ) 45.4 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.5 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.6 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.7 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.8 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.9 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.10.a telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.11 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.12 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.13 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.14 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.15 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( composite ) 45.16 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.17 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.18 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.19 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through provided pvc rigid pipe / casing capping. 45.19.1 1 pair, 0.5 mm gauge ( only supply ) 45.19.2 1 pair, 0.5 mm gauge ( only labour ) 45.19.3 1 pair, 0.5 mm gauge ( composite ) 45.19.4 2 pair, 0.5 mm gauge ( only supply ) 45.19.5 2 pair, 0.5 mm gauge ( only labour ) 45.19.6 2 pair, 0.5 mm gauge ( composite ) 45.19.7 5 pair, 0.5 mm guage ( only supply ) 45.19.8 5 pair, 0.5 mm guage ( only labour ) 45.19.9 5 pair, 0.5 mm guage ( composite ) 45.19.10 providing & installation of analogue telephone instrument 45.19.11 providing testing cord for crone block ( only supply ) 45.19.12 providing crone tool ( only supply ) 45.19.13 replacement of cord for tele. instrument, with rj 11 jack at both ends. ( only supply ) 45.19.14 servicing / repair of telephone instrument ( composite ) 45.19.15 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( only supply ) 45.19.16 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( labour ) 45.19.17 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( composite ) 45.19.18 providing & installation of cordless telephone instrument 45.19.19 providing & installation of caller id telephone instrument 45.19.23 supply of camera equivalent 1.3mp / 2mp ip ir dome camera 45.19.24 supply of camera ( 2mp ) ip ir bullet camera 45.19.27 camera turbo hd720p or equivalent , indoor ir turret 1.0 megapixel analogue camera 45.19.28 supply of crimping tool 3 in 1 modular crimping tool, rj45, rj11 cat5e / cat6 lan cutter with cable cutter 45.19.29 sitc of 8 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.30 sitc of 16 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.31 sitc of 24 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.32 supply of 8 port normal switch or equivalent 45.19.33 supply of cat 6 patch cord 01 mtr 45.19.34 supply of cat 6 patch cord 03 mtr 46.1 battery system supply, installation, testing & commissioning of 2 volt batteries suitable 150 ah lead acid battery set and buy back of old battery ( only supply ) 46.2 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.3 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.4 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only supply ) 46.5 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.6 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.7 supply, installation, testing & commissioning of 12 volt smf batteries . ( only supply ) 46.8 supply, installation, testing & commissioning of 12 volt smf batteries . ( only labour ) 46.9 supply, installation, testing & commissioning of 12 volt smf batteries . ( composite ) 46.10.a supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( only supply ) 46.11 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups.. ( only labour ) 46.12 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( composite ) 46.13 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( supply ) 46.14 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( labour ) 46.15 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( composite ) 46.16 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.17 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.18 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg setand buy back of old battery ( composite ) 46.19 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only supply ) 46.20 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only labour ) 46.21 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( composite ) 46.22 distilled water for batteries ( lt. ) ( only supply ) 46.23 battery solution ( litre ) ( only supply ) 46.24 petroleum jelly ( kg ) ( only supply ) 46.25 castrol make ap 3 ball bearing grease ( only supply ) 46.26 battery cell tester, 2 v dc ( only supply ) 46.27 battery for emergency tube light ( only supply ) 46.28 hydrometer for battery solution checking ( only supply ) 46.29 rechargeable battery, 9 v ( for mike etc ) ( only supply ) 46.30.a rechargeable battery, 1.5 v ( only supply ) 46.31 pencil cell for a / c remote ( only supply ) 46.32 pencil cell for cordless bell ( only supply ) 46.33 pencil cell for urinal sensor, clock and general use ( only supply ) 46.34 charger for rechargeable batteries of best quality ( only supply ) 46.35 crc / ctc etc. for general maintenance ( only supply ) 46.36 steelgrip pvc insulation tape ( only supply ) 46.37 cutter machine blade ( only supply ) 46.38 supply of battery connetion cords / leads having lsuitable lug / clamp at the end etc with size of core / wire to connect the battery to ups / chargers etc. all as per instructions of ( only supply ) 46.39 supply of 12 v / 6 ah to 10ah range maintenance free / sealed rocket / / amara raja or other equivalent battery suitable for ups. prior approval for make & other specification is required. ( only supply ) 46.40.a supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only supply ) 46.41 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only labour ) 46.42 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( composite ) 46.43 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only supply ) 46.44 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only labour ) 46.45 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( composite ) 46.46 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only supply ) 46.47 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only labour ) 46.48 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( composite ) 46.49 12volt 26ah maintenance free battery ( only supply ) 46.50.a 12volt 26ah maintenance free battery ( only labour ) 46.51 12volt 26ah maintenance free battery ( composite ) 46.52 12volt 42ah maintenance free battery ( only supply ) 46.53 12volt 42ah maintenance free battery ( only labour ) 46.54 12volt 42ah maintenance free battery ( composite ) 46.55 12volt 7ah maintenance free battery ( only supply ) 46.56 12volt 7ah maintenance free battery ( only labour ) 46.57 12volt 7ah maintenance free battery ( composite ) 46.58 12volt 12ah maintenance free battery ( only supply ) 46.59 12volt 12ah maintenance free battery ( only labour ) 46.60.a 12volt 12ah maintenance free battery ( composite ) 46.61 12volt 7.5ah maintenance free battery ( only supply ) 46.62 12volt 7.5ah maintenance free battery ( only labour ) 46.63 12volt 7.5ah maintenance free battery ( composite ) 47.00 the system of wiring shall consist of isi marked single core, pvc insulated, frls, 1100 volt grade, stranded, flexible copper conductor wires as per is : 694 amended upto date. 47.1 copper wires pvc , panel wires for interconnections. 1.5 sq. mm ( only supply ) 47.2 1.5 sq. mm ( only labour ) 47.3 1.5 sq. mm ( composite ) 47.4.a 2.5 sq. mm ( only supply ) 47.5 2.5 sq. mm ( only labour ) 47.6 2.5 sq. mm ( composite ) 47.7 4 sq. mm ( only supply ) 47.8 4 sq. mm ( only labour ) 47.9 4 sq. mm ( composite ) 47.10.a 6 sq. mm ( only supply ) 47.11 6 sq. mm ( only labour ) 47.12 6 sq. mm ( composite ) 47.13 10 sq. mm ( only supply ) 47.14 10 sq. mm ( only labour ) 47.15 10 sq. mm ( composite ) 47.16 16 sq. mm ( only supply ) 47.17 16 sq. mm ( only labour ) 47.18 16 sq. mm ( composite ) 47.19 25 sq. mm ( only supply ) 47.20.a 25 sq. mm ( only labour ) 47.21 25 sq. mm ( composite ) 47.22 35 sq. mm ( only supply ) 47.23 35 sq. mm ( only labour ) 47.24 35 sq. mm ( composite ) 47.25 50 sq. mm ( only supply ) 47.26 50 sq. mm ( only labour ) 47.27 50 sq. mm ( composite ) 47.28 70 sq. mm ( only supply ) 47.29 70 sq. mm ( only labour ) 47.30.a 70 sq. mm ( composite ) 47.30.1 95 sq. mm ( only supply ) 47.30.2 95 sq. mm ( only labour ) 47.30.3 95 sq. mm ( composite ) 47.31 connection wire for strip heaters along with porcelain balls over it etc. ( only supply ) 47.32 connection wire for strip heaters along with porcelain balls over it etc. ( only labour ) 47.33 connection wire for strip heaters along with porcelain balls over it etc. ( composite ) 47.34 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only supply ) ( one pack ) 47.35 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only labuor ) 47.36 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( composite ) 47.37 supply of various kinds / sizes of ms / gi bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.38 supply of various kinds / sizes of brass bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.39 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 6 mm 47.40 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 8 mm 47.41 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 10 mm 47.42 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 12 mm 47.43 supply of verious size of drill bit 47.43.1 drill bit 3 / 16 ms 47.43.2 drill bit 3 / 16 concrete 47.43.3 drill bit 3 / 16 hammering 47.43.4 drill bit 1 / 8 ms 47.43.5 drill bit wooden set 47.43.6 drill bit concrete set 47.43.7 drill bit roraty hammer 4mm 47.43.8 drill bit roraty hammer 8 mm 47.43.9 drill bit roraty hammer 10 mm 47.43.10 drill bit roraty hammer 12 mm 47.43.11 drill machine rotary hammering type 47.43.12 drill pair set mm 47.43.13 drill pair set inches 47.43.14 mini hacksaw blade taparia make 47.43.15 hacksaw blade big size 47.43.16 mini hacksaw blade taparia make with frame 47.43.17 hacksaw blade big size with frame 47.43.18 hole saw cutter ms 16mm to 32mm 47.43.19 hole saw cutter ms 32mm to 75mm 47.43.20 hole saw cutter ms 75mm to 150mm 47.43.21 hole saw cutter ms 150mm to 300mm 47.43.22 pvc grip rawal plastic wall plug per pkt qty 200each 47.43.23 grinding wheel blade 48.1 oil filtration for 2 mva transformer 48.2 oil filtration for 4 / 4.5 mva transformer 48.3 supply & topping up of transformer oil 48.4 yearly servicing for air circuit breakers, 800a , 1000 a / 1250 a / 1600 a / 2000a / 2500a / 3200 a, 440 v, mpact, ge make , abb , sterling existing make , testing of breakers , all type test to be carry out , greasing activity, and complete servicing. 48.5 yearly servicing of circuit breakers 48.5.1 33 kv sf6 circuit breaker 48.5.2 11 kv sf6 circuit breaker 48.5.3 33kv vacuum circuit breaker 48.5.4 11kv vacuum circuit breaker 48.6 testing & calibration of all types of relays, existing makes relays in ht panel, lt panel 48.6.1 cdg 31 / cdag 51 48.6.2 vajh / vajc 48.6.3 vaa / vdg 48.6.4 vtt 48.6.5 vagm / cag / ccum / ycgf / cdv / mfvum 48.6.6 vax 48.6.7 apfc relay 48.6.8 tcs relay ber 2 / ber1 48.6.9 feeder protection relay bcf1 48.6.10 lock out relay 86 48.6.11 restricted earthfault relay 48.6.12 reverse power relay 48.6.13 earthfault relay 48.6.14 calibration of multimeter , clamp meter and megger, earth tester 48.7.1 annual servicing for transformers 2.0 mva 48.7.2 annual servicing for transformers 4.5 / 4.0 mva 48.8 cable fault detecting / fault finding for all sizes of cables. 48.9 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only supply ) 48.10.a supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only labour ) 48.11 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( composite ) 48.12 testing & calibration of all types of energy meter 48.13 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only supply ) 48.14 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only labour ) 48.15 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( composite ) 48.16 providing pair of duly tested rubber hand glows suitable for working on 33kv supply ( only supply ) 48.17 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only supply ) 48.18 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only labour ) 48.19 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( composite ) 48.20.a supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only supply ) 48.21 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only labour ) 48.22 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( composite ) 48.23 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class a insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only supply ) 48.24 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only labour ) 48.25 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( composite ) 48.26 supplying standerd first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage ( band aid ) adhesive tape for medicinal use, scissors, anti septic solution etc. ( only supply ) 48.27 testing and calibration of energy meters. 48.28 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only supply ) 48.29 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only labour ) 48.30.a supply and fixing of 33kv, epoxy type insulator for bus bar support ( composite ) 49.1 pa address system male –female, all kinds of audio / video pins ( only supply ) ( pair ) 49.2 male–female, all kinds of audio / video pins ( only labour ) ( pair ) 49.3 male –female, all kinds of audio / video pins ( composite ) ( pair ) 49.4 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only supply ) 49.5 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only labour ) 49.6 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( composite ) 49.7 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only supply ) 49.8 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only labour ) 49.9 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( composite ) 49.16 cable tie nylon 6 / 6 – uv stabilized uv stabilized nylon 6 / 6 use in continuous or extended exposure to outdoor sunlight. weather resistant grade, enduring additional ultraviolet ( uv ) light. 49.16.1 as per 49.16 for 100 mm size pkt for 100 nos ( only supply ) 49.16.2 as per 49.16 for 200 mm size pkt for 100 nos ( only supply ) 49.16.3 as per 49.16 for 300 mm size pkt for 100 nos ( only supply ) 49.17 multimeter make mecho , 415volt ( only supply ) 49.18 clamp meter mecho make , 415volt ( only supply ) 49.19 hand driven insulation tester 500volt ( only supply ) 49.20.a meggar digital insulation tester 500volt ( only supply ) 49.21 supply, installation, laying and connection of g.i. perforated & ladder type cable tray with bends, tees, clamps and couplers for fixing of cable with suitable ms structure and anchor fastner for supporting and necessary hardware with necessary welding has to be done to complete the job from isa / ismc / plate. the job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . all material shall be hot dip galvanised as per is ( 816 g / m2 ) and specifications. the structural steel supports for the trays are to be provided at every 1 mtrs. as per technical specifications. 49.21.1 600mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.2 300mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.3 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.4 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) perforated type tray 49.22 fiber accessories 49.22.1 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( only supply ) 49.22.2 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( composite ) 49.22.3 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( only supply ) 49.22.4 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( composite ) 49.22.5 supply of sm duplex type 03 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.6 supply of sm duplex type 10 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.7 supply of hdmi cable for monitor including end connectors 49.22.8 fiber core splicing charges per core composite work...

Directorate Of Municipal Administration - Maharashtra

37141987 tender for supplying required electrical materials and doing essential electrical work under municipal council hinganghat 2nd call. 1 supplying & erecting h.m.s. p.v.c. conduit 20 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 2 supplying & laying hms pvc conduit 20 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 3 supplying & erecting hms p.v.c. conduit 25 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 4 supplying & laying hms pvc conduit 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 5 supplying and erecting upvc reinforced flexible conduit 20 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 6 supplying and erecting upvc reinforced flexible conduit 25 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 7 supplying and erecting hms pvc conduit 20 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 8 supplying and erecting hms pvc conduit 25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 9 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 20 mm with accessories on wall / ceiling as per specification no: wg ma / con. 10 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 25 mm with accessories on wall / ceiling as per specification no: wg ma / con. 11 supplying & erecting mains with 2x1.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 12 supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 13 supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 14 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 15 supplying & erecting mains with 2x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 16 supplying & erecting mains with 3x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 17 supplying & erecting mains with 3x4 sq.mm fr copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 18 supplying & erecting mains with 3x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 19 supplying & erecting mains with 3x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 20 supplying & erecting mains with 4x16 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 21 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 22 supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6a. erected on filledpolypropylene board or polished double wooden block / pvcjunction box. 23 supplying and erecting isi mark modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 25 supplying and erecting isi mark modular type switch 16 / 20 a with indicator, duly erected on provided plate and box with wiring connections complete. 26 supplying and erecting isi mark modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete. 27 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 28 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 29 supplying and erecting isi mark modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 30 supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. 31 supplying and erecting isi mark modular type blanking plate two module, duly erected on provided plate & box. 32 supplying and erecting pvc surface modular switch box with double mounting plate for 2 modules duly erected. 33 supplying and erecting pvc surface modular switch box with double mounting plate for 3 modules duly erected. 34 supplying and erecting pvc surface modular switch box with double mounting plate for 4 modules duly erected. 35 supplying and erecting pvc surface modular switch box with double mounting plate for 6 modules duly erected. 36 supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 modules complete duly connected. 37 supplying and erecting pvc surface modular switch box with double mounting plate for 12 modules duly erected. 38 supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. 39 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. 40 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match thebackground. 41 supplying and erecting 16 / 20 / 25 a starter ( modular range ) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 42 supplying and erecting isi mark modular type 5 pin socket with safety shutters 3 module socket 6a 240v ac supply, duly erected on provided plate and box with wiring connectionscomplete duly erected. 43 point wiring for light / fan / bell in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw / sw 44 point wiring for independent plug in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as perspecification no: wg pw / sw 45 point wiring for light / fan / bell concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm. ( 2+1e ) fr grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / cw 46 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg pw / sw 47 wiring for plug on board with switch socket, copper wiring and earthing as per specification no: wg pw / sw 48 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw / sw 49 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories as per specification no: wg pw / sw 50 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no:wg pw / sw 51 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 52 point wiring in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wgpw / sw 53 point wiring for independent plug in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 54 supplying & installing utp networking cat 6 cable suitable for lan / wan computer net working as per specification no wg coc / nc 55 dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no: wg dm / pw 56 dismantling the existing aluminium / copper mains, submains wiring upto 10 sq.mm. along with accessories etc complete as per specification no: wg dm / pw 57 supplying and erecting led square / circular 9 to 12w down lighter having pressure die cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 58 supplying and erecting led square / circular 13 to 15w down lighter having pressure die cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 59 supplying and erecting square / round shaped crca / diecast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13w to18w with provision for plane front frame with translucent cover fixed to the housing complete. 60 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housingcomplete. 61 supplying and erecting led flexible strip light 5m length upto 25w conforming ip 65 of any colour with driver complete. 62 supplying & erecting led 18w tube light fitting ( 4 feet ) with polycarbonate housing, heat sink, integrated hf electronic driver complete. 63 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 64 supplying and erecting electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and ( effective range upto 45 meter ) bell on 250 v a.c. supply. 65 supplying and erecting electronic type driver for indoor led upto 19w 24w fixtures suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 66 supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminiumalloy and heat sink extruded aluminium complete per specification no . fg odf / fls2. 67 supplying and erecting led flood light fitting of 50w, including lamp, with pf > 0.95, class ip 65 and above class ip 65 and above housing of pressure die cast aluminium alloy andheat sink extruded aluminium complete per specification no fg odf / fls 2 68 supplying and erecting recess mounted 20w led wall washers, tilted 70° outwards and swivels 360° to offer best illumination on the wall with any colour with driver complete. ( including compatible driver ) 69 supplying & erecting 20w led par ( 30 lamp e 27 base, spoto series ) lights by making necessary arrangement / recess in wall to make it flush with surface. 70 supplying and erecting cylindrical shaped integral decorative with high power 12w 16w led bollard upto 1000mm with opal acrylic diffuser and ip65 protection on provided foundation complete. 71 supplying and erecting mushroom shaped integral 12w 16w led decorative bollard upto 680mm with ip65 protection on provided foundation complete. 72 erecting the departmentally supplied wp led street light / flood light fitting upto 80w. 73 erecting departmentally supplied led street light / flood light fitting upto 150w . 74 erecting departmentally supplied led street light / flood light fitting upto 400w . 75 supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb 76 maintenance of non eesl led light of all wattages of approximately 500 quantity 77 maintenance of55 nos of street light switiching box 78 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 79 supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. 80 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 81 supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5metre length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. 82 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 83 supplying and erecting fresh air cum exhaust fan of light duty250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 84 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 85 supplying and erecting five star rated energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn / cf 86 supplying and erecting condenser 2.5 micro farad for ceiling fan 87 supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 88 providing recess in brick wall suitable forerection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. 89 providing recess in brick wall suitable forerection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 90 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaustfan of 300 mm as per specification no fg fas / msc 91 dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with accessories, g.i. down rod, frame etc. and making the site clear. 92 providing fully comprehensive annual maintenance service for 80 / 120 / 150 ltr. water cooler unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares including minor electrical parts within 48 hours. 4 ) refrigerant charging if required. 5 ) if failed to rectify the fault within 48 hrs penalty shall be charged rs.50 / per day.the job exclude sheet metal work and plastic material. 93 providing servicing of 1 / 1.5 / 2 / 3 tr capacitysplit / window air conditioning unit complete with allnecessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to engineer incharge. 94 providing annual comprehensive maintenance contract for 1.5 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 95 providing annual comprehensive maintenance contract for 2 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 96 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 1.5 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 97 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 2 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 98 providing replacement of unserviceable starting capacitor for a / c unit. 99 providing replacement of unserviceable running capacitor for a / c unit. 100 providing replacement of unserviceable fan motorcapacitor for a / c unit. 101 providing replacement of unserviceable pcb for a / c unit upto 3 tr capacity. 102 providing repair of of faulty pcb for air conditioning unit upto 3 tr capacity. 103 supplying and installing of new fan motor for condenser for air conditioning unit 104 providing vaccumising the airconditioner system and charging with r 22 refrigerant for air conditioning unit. 105 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 1.5tr window / split air conditioning unit. 106 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 2tr window / split air conditioning unit. 107 providing replacement of existing unserviceablecompressor of 150 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerent with guarantee for one year. 108 providing replacement of existing unserviceablecondensor coil of 40 / 80 / 150 litre cooling capacitywater cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 109 providing replacement of existing unserviceable ss water tap of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 110 providing replacement of existing unserviceable relay 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 111 providing replacement of existing unserviceablethermostat of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 112 dismantling the existing split type air conditionerof any type and capacity safely without any damages and making the site clear. 113 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / gi frame as per specification no. sw swr / mdp . 114 supplying and erecting double pole metal clad switch with hc type fuse 240v, 63a on iron / gi frame as per specification no. sw swr / mdp. 115 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specification no. sw swr / mtp. 116 supplying and erecting triple pole metal clad switch and fuse 415v, 100a on angle iron / gi frame as per specification no. sw swr / mtp. 117 supplying and erecting triple pole metal clad rewireable fuse switch 415v, 200a on angle iron / gi frame as per specification no. sw swr / mtp. 118 supplying and erecting four pole metal clad on load change over switch 415v, 100a erected on angle iron / gi frame complete. 119 supplying and erecting four pole metal clad on load change over switch 415v, 200a erected on angle iron / gi frame approved make complete. 120 supplying and erecting metal clad distribution board 240v, 8 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 121 supplying and erecting metal clad distribution board 240v, 6 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 122 supplying and erecting metal clad distribution board 240v, 4 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 123 supplying and erecting metal clad distribution board 415 v, 8 way, 32a. per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 124 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 125 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 126 supplying, erecting & marking spn mcb 6a to 32a, bseries ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 127 supplying, erecting & marking tpmcb 6 a to 32a in provided distribution board as per specification no. swswr / mcb 128 supplying, erecting & marking fpmcb 6a to 32a in provided distribution board as per specification no. sw swr / mcb 129 supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 130 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 131 supplying, erecting & marking tpn mcb 6a to 32a, c series in provided distribution board as per specification no. sw swr / mcb 132 supplying, erecting & marking tpn mcb 40a to 63a, c series in provided distribution board asper specification no. sw swr / mcb 133 supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 134 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 135 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 63a with required wiring connections and lugs etc. in provided distribution board complete. 136 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100a with required wiringconnections and lugs etc. in provided distribution board complete. 137 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board complete. 138 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63a in provided distribution board complete. 139 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 80 / 100a in provided distribution board complete. 140 supplying and erecting triple pole and neutraldistribution board ( tpndb ) surface / flushmounted suitable for spmcb of 12 poles on iron / gi frame ( horizontal busbar type ) as per specification no. swswr / mcbdb 141 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 142 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 143 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 144 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 145 supplying & erecting original 1.25 mm crca sheet metal enclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete erected on angle iron / gi frame. 146 supplying and erecting blanking plate of suitable size on mcb db complete. 147 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 16 / 25a complete as per specification no.sw rccb / rccb 148 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 149 providing, erecting and commissioning 4 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 150 providing, erecting & commissioning 4 pole rccb of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 100a, complete as per specification no. sw rccb / rccb 151 supplying & fixing crca sheet box with earthing terminals for housing 2 pole rccb on iron frame / laminated board complete. 152 supplying & fixing crca sheet box with earthing terminals for housing 4 pole rccb on iron frame / laminated board complete. 153 supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. 154 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 155 supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 156 supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 157 supplying and erecting gi sheet 1.6 mm ( 16 swg ) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for medium voltage installation. 158 supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions bythe authority. 159 supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 160 supplying, erecting & terminating xlpe armoured cable 3 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 161 supplying, erecting & terminating xlpe armoured cable 3 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 162 supplying, erecting & terminating xlpe armoured cable 3 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 163 supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 164 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 165 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in providedtrench / pipe as per specification no. cb lt / al 166 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 167 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / cu 168 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 169 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 90 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 170 supplying & erecting water tight terminal box of 1.6 mm ( 16 gauge ) crca sheet of size 200 x 150 x 150 mm. complete on pole as per specification no. cb sb 171 supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 172 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75 m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp 173 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 174 supplying and erecting pre stressed cement concrete ( psc ) rectangular pole of top 105 x 115 mm & bottom of 105 x 315 mm 9 m long ( 200 kg ) complete erected in provided c. c. foundation & muffing ( square / round ) as per specification no. oh pl / psc 175 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 176 supplying & erecting ms pole bracket, for oh conductor fabricated from ism channel, 75x40x6mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 177 supplying & erecting ms pole bracket, fabricated from ism channel, 75x40x6mm, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 178 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 179 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 180 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips , nuts and bolts, complete. 181 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length andpole clamps duly erected in provided cement concrete foundation. 182 supplying and erecting fibre / pvc spacers for lt overhead line 3 to 5 conductors complete erected. 183 supplying and erecting ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 184 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 185 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 186 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep 187 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 188 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 189 supplying and erecting aluminium strip of required sizes used for earthing on wall and / or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required.as per specification no ea ep. 190 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary giclamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no ea ep. 191 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit withscrews in an approved manner. 192 providing printed instruction chart for treating persons suffering from electric shock, printed in english & marathi and duly laminated complete. 193 supplying and fixing pvc synthetic elastomer electrically insulating mat with class a insulation conforming to is: 15652 – 2006 & cpri tested having 2 mm thickness upto 3.3 kv 194 supplying and fixing pvc synthetic elastomer electrically insulating mat with class b insulation conforming to is: 15652 – 2006 & cpri tested having 2.5 mm thickness upto 11 kv 195 supplying shock proof leather safety shoes of electrical grade of standard size as is :11226, 14544 duly tested, with necessary test certificate from manufacturer. 196 carrying out servicing of dg set upto 50 kva with / without amf panel of any make to ensure smooth running of dg set for 30 mins on load. checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. inspect alternator, stator and rotor for normal speed & proper frequency, examine batterycharging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking v belts with necessary adjustment, checking and retightening of nut bolts including coupling boltsof engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of avr, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, cleaning of dg set internally using blower, cleaning radiator and submit the servicing report to engineer in charge. ( non comprehensive ) as per specification no. gen ser amc 197 topping up new lubricating oil 15w / 40 grade of approved make as per is 13656 : 2014 198 topping up new glycol based coolant 50 / 50 with operating range from 118°c to 37°c of approved make 199 supplying and erecting v belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for dg set upto 100kva 200 supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for dg set upto 62.5 kva. 201 supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for dg set upto 50 kva. 202 supplying and erecting stop solenoid assembly 12v / 24v single coil energized to run with or without primary etc complete suitable for dg set upto 125 kva. 203 supplying and erecting air cleaner / air filter element suitable for dg set upto 40 kva 204 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 205 making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exnctr 206 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 207 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing andfinishing complete. ( above 6 m to 9 m poles ) 208 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 209 making m 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with thehelp of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 210 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. specification no cw ptg / ptp. 211 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 212 rewinding motor of the 1200 / 1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption withguarantee for one year. 213 replacing the existing ball bearing of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 214 replacing the existing bush / rubber, ring, washers of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 215 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c.. submersible / centrifugal pump set upto 2 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 216 supplying and installing 25 kva koel generators generator panel with 3 years warrenty. 217 doing rewinding and repairing cooling fan of 1400rmp 220v 218 doing repairing and fixing of thebroken main gate of 25 kva generator with required accessories. 219 supplying and installing fuel cap for 25 kva generator. 220 doing servicing of highmast ( upto 15 mtr ) with lowering of lights, cleaning ropes pathway lubricating the mechanisam with all necessary accessories. 221 supplying and erecting new rope in the highmast ( upto 15 mtr ) by dismantling highmast with proper equipments. 222 maintenance of 15 nos ofdecorative pole of 15w at park...