Reserve Bank Of India - Maharashtra

37872535 sitc of approved make occupancy sensor to the false supply, installation, testing and commissioning ( sitc ) of approved make occupancy sensor to the false ceiling in the cabin with required hardware. rate shall include for sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 2 2 primary point sitc of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 3 3 secondary point supply, installation, testing and commissioning ( sitc ) of approved make 3 nos. 2.5 sq mm copper conductor pvc frlsh insulated wire 4 4 lighting and raw power mcbdb supply, installation, testing and commissioning of approved make 3 phase, 8 way per phase isolation double door metallic mcbdb with per phase isolation kit using required hardwares 5 5 sitc of approved make 4 by 16 sqmm copper conductor supply, installation, testing and commissioning of approved make 4c x 16 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth wire with required support from ceiling 6 6 termination of above cable using required size brass cable gland termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. rate shall include for termination of both gi wire at two separate points. 7 7 supply and installation of gi perforated cable tray supply and installation of gi perforated cable tray of minimum 18 swg thick, 100 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod 8 8 supply and installation of gi perforated cable tray of minimum 18 swg thick supply and installation of gi perforated cable tray of minimum 18 swg thick, 150 mm width and 25 mm height; true ceiling support with minimum 10 mm size gi rod, nut, washers, anchor fasteners and 18 swg gi c channel for support to cable tray at required interval as per site condition. rate shall include for any other material required for completion of this work. 9 9 supply and installation of approved make 2c by 1.5 sq mm supply and installation of approved make 2c x 1.5 sq mm copper conductor pvc insulated fire alarm armoured cable with required support from ceiling. 10 10 assembly, installation, testing and commissioning of track light assembly, installation, testing and commissioning of track light fittings supplied by bank. 11 11 installation, testing and commissioning of led downlighter installation, testing and commissioning of led downlighter supplied by bank. rate shall include for providing marking to false ceiling. 12 12 installation, testing and commissioning of 2 x 2 led installation, testing and commissioning of 2 x 2 led panel supplied by bank. to grid type false ceiling. 13 13 installation, testing and commissioning of hanging light installation, testing and commissioning of hanging light fitting supplied by bank. 14 14 profile light fitting installation, testing and commissioning of profile light fitting supplied by bank. 15 15 sitcof approved make 6 module flush mounted aluminium factory finish popup box supply, installation, testing and commissioning of approved make 6 module flush mounted aluminium factory finish popup box with back protecting cover on workstation / side table in the cabin and suitable size plastic white plates with frame 16 16 power plug point supply, installation, testing and commissioning of power plug point using approved make and model suitable size plastic white plates with frame, 16 amp led indicator switch 17 17 group of two light plug point supply, installation, testing and commissioning of group of two light plug point using approved make and model suitable size plastic white plates with frame, minimum 6 amp switch qty 02 nos 18 18 ups supply mcbdb supply, installation, testing and commissioning of approved make 12 way spn double door metallic mcbdb using required hardwares in concealed manner by making opening in wall and refilling the area surrounding to it by mortar 19 19 air conditioning power supply mcbdb supply, installation, testing and commissioning of approved make three phase, 4 way per phase isolation double door metallic mcbdb 20 20 sitc of approved make 4c x 4 sq mm supply, installation, testing and commissioning of approved make 4c x 4 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 2 runs of 8 swg gi earth 21 21 sitc of approved make 3c x 2.5 sq mm supply, installation, testing and commissioning of approved make 3c x 2.5 sq mm copper conductor xlpe frls insulated 1100 volt armoured cable and 12 swg gi earth wire on wall using heavy duty gi saddles 22 22 termination of above cable using required size brass cable gland termination of above cable using required size brass cable gland with nickel plated and required size & type copper lugs preferably insulated. 23 23 plug point for ac supply, installation, testing and commissioning of approved make single phase 20 amp metal clad dpmcb, plug, socket box, in flush / surface manner as per site condition and 20 amp dpmcb, 20 amp metal clad top. 24 24 ups power dpmcb in ms enclosure supply, installation, testing and commissioning of approved make 16 amp dpmcb and required size metal enclosure in flush / surface manner as per site condition 25 25 telephone point supply, installation, testing and commissioning of approved make 2 pair 0.5 mm dia copper conductor pvc insulated and sheathed urarmoured telephone cable from mdf to each cabin 26 26 network point supply, installation, testing and commissioning of approved make utp cat 6 cable from network switch to io point of each cabin 27 27 call bell point supply, installation, testing and commissioning of approved make and model plastic white plate 28 28 telephone mdf supply, installation, testing and commissioning of 100 pair powder coated mdf with 10 nos 10 pair krone module, stainless steel krone module stand in flushed manner with required mortar etc 29 29 carefully removing of all mcbdbs carefully removing of all mcbdbs, cables, wires, telephone mdfs, if any on the floor as directed by bank?s engineer and as per site conditions....

Directorate Of Municipal Administration - Maharashtra

37745599 matheran electrical material supply , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning 11kv hrc fuse 10a to 40a for load break switch with necessary nut bolts complete. , supplying, installing, testing and commissioning 11 kv hrc fuse 63a for load break switch with necessary nut bolts complete. , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap ac/wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7tr to 0.9tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning ip epabx for 10 extensions complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 6 x 16 extension complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 3 x 8 extensions complete. , supplying, installing, testing & commissioning analogue type epabx of 3 x 8 extension complete. , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 2280 to 2850lpm at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 45kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 1600 to 1800 lpm at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 30kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning 3 phase, 22/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°c at ambient temp max 50°c & min 5°c at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage & frequency (+15% is tol) 1.80 kw, full load loss at rated current 3.00 kw, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 23 degree of protection, cable box arrangement at hv side & bus duct at lv side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & wti scanner with 3 pt 100 sensors, etc. standard accessories complete with test certificate (as per is:11171 & iec 60076 11) with necessary permissions of electrical inspector, as per specification no. ss tr. , supplying, installation, testing and commissioning 3 phase, 11/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oc at ambient temp max 50oc and min 50oc at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage and frequency (+15% is toi) 1 kw, full load loss at rated current 3.15 kw, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 21 degree of protection, cable box arrangement at hv side and bus duct at lv side, with rating and diagram plate, base channel, earthing terminals and wti scanner with 3 pt 100 sensors, etc., standard accessories complete with test certificates (as per is:11171 & is 2026) with necessary permissions of electrical inspector as per specification no. ss tr. , supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results specification no. ea mobi , supplying, fixing, and configuring modularised multi service router 802.11/a/n/ac unified wave 2.5 ghz, with rj 45 port, supporting 1 to 13 channels for 2.4 ghz, with unified wireless access point complete , supplying, fixing, and configuring 24 ports with 4 (sfp+) port, ethernet managed switch with web view/cli, 6kv surge protection on ethernet port and console port for management in provided rack as per specification no. wgnwc/gbs , supplying, fixing, and configuring 24 ports + 4 (sfp+) port, managed layer 2, poe switch of , 370w, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing, and configuring 20 sfp ports + 4 combo sfp 10/100/1000 base t erected in provided rack complete. , supplying, fixing, and configuring 20 (1g rj45) ports + 4 combo 1g ports + 4 10g (sfp+) ports, layer 3 switch, si image, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr / mcbcos , supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of ....... hrs. pwm & igbt based, with 0.8 to unity output pf complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 82.5 kva up to 100 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 62.5 kva up to 82.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 50 kva up to 62.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 40 kva up to 50 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 35 kva up to 40 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 25 kva up to 35 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 20 kva up to 25 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 15 kva up to 20 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 125 kva up to 140 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 100 kva up to 125 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 10 kva up to 15 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of diesel generating set with standard control panel with alternator of 5 kva continuous rating, single phase, 230v, 50c/s 0.8 p. f. ac supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self excited, selfregulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 1.3 ltr/hr @75% loading. engine and alternator directly coupled on a common fabricated steel base plate with anti vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. the complete set enclosed in acoustic enclosure made of 18 swg crca sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 db at 1.0 m. the engine with first filling of oil, diesel not less than 13 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 14.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 145 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 11.3 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 9.98 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 7.47 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.9 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 34.40 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db(a) at 1.0 m, provided with first filling of oil, diesel not less than 300 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.8 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 50 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 17.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 2.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of 6kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 3kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 28hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 20hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56°c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 12hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 6a to 32a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & commissioning mdf box 600x600 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 500x500 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 400x400 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 300x300 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 250x250 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 200x200 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 150x150 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 100x100 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 100a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying table fan of a.c. 230 v. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and hand shield type 3 pin plug top. , supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying led concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4w 6w led including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. , supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 star inverter type, stabilizer free operation suitable for operation on 100v/300 v, 50hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. , supplying and plugging 3 m fibre patch cord lc sc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc sc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and laying rigid steel conduit 16 swg 32 mm dia. with necessary accessories in rcc work/false ceiling/false flooring as per specification no: wgma/cc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and installing, testing & commissioning of digital (hybrid) type epabx of 6 x 32 extensions suitable upto 96 extensions complete. , supplying and fixing wireless n 150 desktop adapter in provided computer as per specification no. wg nas/lanc2 , supplying and erecting vpit heavy duty copper wound ballast 230v for 80 150w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting vpit compound heavy duty copper wound ballast for 230v for 250w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system. , supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) , supplying and erecting two pole power contactor 230 v, 32 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole metal clad changeover switch 240 v, 32 a erected on angle iron/gi frame and duly connected with suitable wire leads complete , supplying and erecting triple pole mini feeder pillar with 500v, 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a with aluminium bus bar erected in 14 swg crca sheet box with supporting angles, self locks, gasket having ip54,ik10 protection and slanting top to be erected on provided foundation complete as per specification no. sw , supplying and erecting t8 fluorescent tube day light 1200mm, 36 w , supplying and erecting t5 24 w energy efficient fluorescent tube. , supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt/bpc , supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.ap wh/stwh , supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kwh / 24 hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 2 ways (2 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 10 ways (10 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting shockproof t. switch 16 a porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof piano type switch 250 v, 16 a, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (trs type) pvc insulated copper wire of size 0.5 sq mm 5 m length connected to the point. , supplying and erecting shockproof 6a porcelain base t.switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected , supplying and erecting shockproof 3 pin plug socket 6a with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof 3 pin plug socket 16a with porcelain base/ flush type erected on filled polypropylene (is:14772 2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting rectangular shaped led panel light(1200mm x 300mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6a erected on m.s box made of 16 swg sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6 a combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor. , supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con , supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected , supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 1 module complete duly erected. , supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. , supplying and erecting pvc surface modular double mounting plate 8 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 6 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 4 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 3 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 2 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 16/18 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 12 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 1 module complete duly erected. , supplying and erecting pvc slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. , supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box . , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. , supplying and erecting porcelain base iron clad cut out hc type 415v, 63a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 32a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 200a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 16a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 100a erected on polished wooden block. , supplying and erecting pole clamp made from 50x6mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting pole clamp made from 50x10mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 63a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, , ip 54 and ik10 protection, 45 a tp contactor for automatic switching of luminaires, 2 no 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 32a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, ip 54 and ik10 protection, 25 a tp contactor for automatic switching of luminaires, 2 no. 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting one/two way piano type switch 6a./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting modular type two way switch 6a / 10a (2 module), duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch one way 16 / 20 a, duly erected on provided plate and box with wiring connections complete with neon indicator. , supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch 16a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type buzzer 220 / 250v, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type blanking plate two module, duly erected on provided plate & box , supplying and erecting modular type bell push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell push 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 6 / 16a fuse unit, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections , supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 600/650w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 1000w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (one module) electronic dimmer 400 / 450w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete , supplying and erecting metal halide lamp double ended 230v, 70 w . , supplying and erecting metal halide lamp double ended 230v, 250 w. , supplying and erecting metal halide lamp double ended 230v, 150 w . , supplying and erecting marine (waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to is 720:2010 , supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with 4x25 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 2x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230v a.c. supply with resetting arrangement complete erected on double wooden/ sunmica board. , supplying and erecting lszh armoured multimode optical fibre cable with 6 fibres, core dia 50/125 ?m (om4) suitable up to 10 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. wg coc/ofc , supplying and erecting led strip light 5m length max. 95 w ip20 class having minimum lumens output of 1600 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50 including driver with 1 year warranty. , supplying and erecting led strip light 5m length max. 45 w ip20 class having minimum lumens output of 800 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50, including driver with 1 year warranty. , supplying and erecting led square / circular max. 7w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led square / circular max. 25 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 18 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led panel light(600mm x 600mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg , supplying and erecting integrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf/fls2. , supplying and erecting integrated led street light fitting 120w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led post top 45w ip65 & ik10 class having die cast aluminium housing with uv protected polycarbonate diffuser, having system lumens output of min.4500 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 30,000 hrs. at l50b50 , including driver complete with 2 year warranty as per specification no fgodf/fls , supplying and erecting integrated led highbay fitting 135w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50,000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 70w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 8400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 5000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 30w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 3000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 195w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 23400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 155w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 18600 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 120w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min.14500 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 800mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 500mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting ignitor suitable for 230v hpsv lamp 70/150/250/400w as specification no. fg fg/as6 , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 70 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head / pin type 230v, 70 w son type. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma/con. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall /ceiling as per specification no: wg ma/con. , supplying and erecting gi wire of high purity of required sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete. , supplying and erecting gi strip of high purity required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint with joints required. as per specification no ea ep. , supplying and erecting gi sheet 0.8 mm (22 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gi sheet 0.6 mm (24 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12w led lamp on provided pipe as per specification no. fg , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, g.l. stay wire 7/8 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop insulator, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable ms clamps duly erected in provided c.c. foundations complete. , supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting g.i. pipe ‘c’ class erw 75/80 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15m long) with pole clamp, made of 50x6mm ms flat, erected on provided rsj pole complete. (add. rs. 25/ per m for extra length beyond 15 m) , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for, 1kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top suitable for with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 4kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting four pole power contactor 430 v, 16 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting flush, shock proof plug socket 6 pin 6a and 16a with switch 16a combined unit erected in recess in 16 gauge m.s sheet box duly painted and connected with earth terminal and leads , supplying and erecting flush type, shockproof plug socket 6 pin 6a and 16a with switch 16a combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with s m screws and duly connected. , supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. , supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. , supplying and erecting exhaust fan heavy duty 230 v, a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 1400 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg , supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn/cf , supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of 28w having service ratio (cmm/w) of min. 8 , pf>0.9, thd , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 76w100w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th , supplying and erecting electronic type driver for outdoor led fittings 46w75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<1 , supplying and erecting electronic type driver for outdoor led fittings 26w45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and , supplying and erecting electronic type driver for outdoor led fittings 151w200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 101w150w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd , supplying and erecting electronic ignitor suitable for 230v metal halide lamp 70/150/250/400w (integral or non integral type luminaires as specification no. fg fg/as6 , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. , supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. as per specification no. eaep. , supplying and erecting control gear for non integral flood light fittings suitable for 2x250w hpsv/mh lamp with all accessories complete. , supplying and erecting control gear for non integral flood light fittings suitable for 1x400w hpsv/mh lamp with all accessories complete. , supplying and erecting condenser for mv/sv/mh lamp 250w,230v as specification no. fg fg/as7 , supplying and erecting condenser for mv/sv/mh lamp 150w,230v as per specification no. fg fg/as7 , supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting c type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting c type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. , supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no ea ep. , supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles a.c. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting acrylic sheet 3 mm thick to be used for covering the crca sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete. , supplying and erecting 75 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 50 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 40 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 30 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 570 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries) , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries , supplying and erecting 12v/80ah to 88ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/7ah 7.5ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/42ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/26ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/17ah 18ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/130ah to 135ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. , supplying and erecting 12.5 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/hm (excluding luminaries , supplying and erecting 12 v/65ah smf battery with battery terminal wire, duly charged complete with 24 months warranty complete , supplying and erecting 11 kv outdoor type gang operated air break, triple pole switch 200 a capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of c class g.l. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground level with necessary clamp. , supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 100 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting ‘d’ type pole clamps, fabricated from 50x6mm ms flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12 exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12 exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(e), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating 11 kv(e), 3 x 70 sq. mm., aluminium conductor xlpe insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. cb ht , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300 x 200 x 150 mm complete on pole as per specification no. cb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 150 x 100 x 100 mm complete on pole as per specification no. cb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 , supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting three phase, 415v, street light control panel up to the max load of 12kw, tpn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 4 pole contactor up to 60a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 2 pole contactor up to 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting single pole cut point channel set of for 11kv ht oh line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. , supplying & erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ cc foundation. , supplying & erecting single phase, 240v, street light control panel up to the max load of 12kw, spn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting single compression type brass cable glands for 4 core 35 sq.mm./3 core 50 sq.mm. for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying & erecting ms pole bracket for lt oh conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 2.25 kw/3 hp with discharge 600/110 litres per minute (lpm) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 1.5 kw/2 hp with discharge 600/140 litres per minute (lpm) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 5.625 kw/7.5 hp with discharge of 780/170 litres per minute (lpm) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 3.75 kw/5 hp with discharge 715/200 litres per minute (lpm) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 230v, single phase 50 cycles a.c. supply of 1.125 kw/1.5hp with discharge 198/50 litres per minute (lpm)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (light house type) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (globe type) suitable for led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. fg , supplying & erecting inline d.p. structure for 11/0.415kv, 63kva transformer with rsj pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of crca sheet 16 swg with 4 pole mccb 100a as incomer & 6 nos. 63a kitkat/mccb for outing circuits. transformer d.p. structure includes the a.b. switch 200a, d.o. fuse set & l.a. set. 2 nos. top channel of size 100x50mm for erection of a.b. switch & 2 nos. base channel of size 100x50mm for erecting transformer channel of size 75x40mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 200 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 300 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete , supplying & erecting g.i. pipe ‘a’ class 75 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting fully automatic star/delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. , supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting four pole on load change over switch, 415v, 63a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 40a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 32a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3 . , supplying & erecting four pole on load change over switch, 415v, 315 320a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 200a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 160a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 100a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 10 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 h.p. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 h.p. , supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 h.p. , supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification no. cb cl/al , supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 30 a, 3 pin plug & earth socket and 30a, 3 pin plug top with 30a triple pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron / gi frame. , supplying & erecting co axial copper cable low voltage grade tri shielded rg11 as per specification no. wg tw , supplying & erecting co axial copper cable low voltage grade tri shielded rg , supplying & erecting cast iron cable indicator plate buried along with route of cable for pvc / xlpe armoured cable as per specification no. cb cip , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 hp consisting of star delta starter having relay range 9 14 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 15 hp consisting of star delta starter having relay range 13 22 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e , supplying & erecting 14w, 230v integral type led lamp suitable for b 22 / e27 base. , supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. , supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 0.5 mm dia, copper jumper wire as per specification no. wg tw , supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. , supply and erecting 9m (clear height) fixed type high mast (top 100mm, bottom 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. oh pl/opl (excluding luminaires). , rewinding the motor of the exhaust fan 900 / 1400 rpm 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year , rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. , rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for original speed and consumption with guarantee for 1 year including transportation from site and back , rewinding of electric motor upto 1 h.p. single phase up to 1400 rpm of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year. , rewinding of electric motor up to 1 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 7.5 h.p. upto 10 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea , rewinding of electric motor above 5 h.p. upto 7.5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 3 h.p.upto 5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 2 h.p. upto 3 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 1 hp upto 2 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. , providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep , providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 kilogram). , providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as per specification no. cb jt/ht , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 400 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 300 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 200 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 150 mm width & 100 mm height comprising all required standard accessories , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 8 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no sw swr/mccbpb. (excluding mccbs) , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 12 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no. sw swr/mccbpb. (excluding mccbs) , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as per specification no. cb jt/lt , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure/panel as per specification no. sw swr/mccb , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. oh pl/opl , point wiring in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/fan/bell in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire with flush type switch and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/cw , point wiring for independent plug, concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/c , point wiring for ceiling fan (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw/hw , making trench in soft soil having 0.9m depth and minimum 0.3 m width as per is for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. external surface duly plastered by 12 mm thick including watering etc complete , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). , excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. , concealing of provided g.i. pipe/h.g. screwed conduit/pvc pipe in wall/floor/false ceiling complete as per specification no:wg pw/cw , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole)....

Directorate Of Municipal Administration - Maharashtra

37720932 supply of electric materials for light dept in shrigonda council , 2 core 2.5 sqmm aluminium wire bundle ( 90 mtr ) 2 core 4 sqmm aluminium wire bundle ( 90 mtr ) 2 core 6 sqmm aluminium wire bundle ( 90 mtr ) 4 flexible wire per mtr 1 core 1 sqmm coppr wire ( per mtr ) 1 core 1.5 sqmm coppr wire ( per mtr ) 1 core 2.5 sqmm coppr wire ( per mtr ) 3 core 1.5 sqmm copper cable ( per mtr ) 4 core 4 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 6 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 10 sqmm xlpe armoured aluminium cable ( per mtr ) 9 4 core copper cable 4 sqmm 4 core copper cable 6 sqmm 13 14 xlpe armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) xlpe armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 151 16 xlpe armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire ( per mtr ) 17 main switch 1 phase 32 a 18 main switch 1 phase 63 a 19 main switch 3 phase 32 a main switch 3 phase 63 a main switch 3 phase 100 a main switch 3 phase 200 a mcb spmcb 5a 24 24 mcb spmcb 6 32a mcb tpmcb 6a to 32a mcb tpmcb 40a to 63a 26 mcb fpmcb 6a to 32a mcb fpmcb 40a to 63a contactor 2 pole 32 a contactor 4 pole 16 a contactor 4 pole 40 a 22 32 ceramic cut out 32a 33 ceramic cut out 63a 34 ceramic cut out 100a 35 35 ceramic cut out 200a 336 insulation tape per box ( 30 piece in box ) 337 led bulb 5 w 38 led bulb 9 w 39 led bulb 15w 40 led bulb 20 w 41 angle holder 42 led tube patti 18 w 21 43 led tube patti 20 w 404 led tube patti 25 w 45 45 clamp for rail, cement pole / clamp clamp for round pole / clamp 46 clamp for highmast / clamp 47 47 bracket for rail, round, cement pole 6 module switch board 12 module switch board 18 module switch board 6*8 module switch board 2 module switch board 48 49 50 51 52 55 53 54 modular 3 pin 6 a socket modular 3 pin 16 a socket 55 56 modular 5 pin 6 a socket modular 5 pin 16 a socket 57 ཆ| 58 fan pvc regulator 59 fan step regulator 60 modular switch 6a 61 modular switch 16a 62 29 bell switch modular 16a 63 39 dp switch modular 16a 64 dp switch modular 32 a 65 bell switch modular 32a ceiling fan 1200 mm ( copper winding ) ceiling fan 900 mm ( copper winding ) wall fan 400 mm 69 standing fan 400 mm 70 fan capacitor 3.15mfd 71 fan capacitor 2.5mfdg 72 dummy plate 73 extension board 74 casing patti per mtr 75 casing pipe 0.5 inch per mtr 76 3 pin plug top 6a 77 3 pin plug top 16a supplying porcelain shackle type lt medium insulator 50 x 89 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 78 79 supplying aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) per mtr 80 supplying aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) per mtr 81 playwood board 6*4 22 82 playwood board 8*6 83 aluminium lug 6 mm 84 aluminium lug 16 mm 85 86 copper lug 6 mm copper lug 16 mm 87 male female pin 88 pvc clamp pocket 89 upto 25w led driver upto 25w led plate upto 25w led spd 26 45w led driver 92 26 45w led plate 93 26 45w led spd 55 46 75w led driver 96 46 75w led plate 97 46 75w led spd 98 office bell 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe ( per mtr ) 99 24 hrs digital / astronomical timer for street light control panel 100 changeover switch 32 a fp 101 changeover switch 63 a fp 102...

Bhiwandi Nizampur City Municipal Corporation. - Maharashtra

37657077 providing and supplying spare part for all types of borewell as per requirement in bncmc area for one year 2023 2024 1 providing and supplying spare part for all type of borewell as per requirment in bncmc area ( year 2023 2024 ) 2 item no. 1 : providing & suppling gi unionmjp elec / mech csr 2021 22 pg no. 11 pw 1 25 mm dia 3 40 mm dia 4 item no. 2 : providing & suppllying gi pipe mjp dsr 2021 22 pg no. 82 / 1 / b 25 mm dia c class 5 32 mm dia c class 6 item no. 3 : supplying g.i. coupling / nipple b class mjp elec / mech csr 2021 22 pg no. 11 pw 3 25 mm dia 7 40 mm dia 8 item no. 4 : supply & erecting & treminating pvc armouredcable 3 core 2.5 sq mm copper conducter continuous 5.48 sq mm ( 12 swg ) gi earth wire complet erected with glands & lgs on wall trusses / pole or laid in providedtrench / pipe as sper specification on cb lt / cu pwd elect mech. csr 2021 2022pg.128 7 2 14 9 item no. 5 : supplying & erecting automatic control panel for 1 ph, 230 volt, a.c. submersible / centrifugal pump set upto 2 hpconsisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosedin crca powder coated vibration proof encloser with ip 54protection. control panel should offer single phasing, phasereversal, phase inbalence etc ( similar to lt model no.mr g2 ) pwd ele csr2021 2022csr page no 219 / 12 4 20 10 item no. 6 : supplying, erecting & terminating pvc armoured cable 2 core 4 sq mm aluminium conductor with continuous 5.48sq mm ( 12 swg ) g.i. earth wire complete erected withglands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / alpwd ele csr2021 2022csr page no 128 / 7 2 9 11 item no. 7 : supplying and erecting submersible pumpset of required hp with 415 v, 50 c / s ac supply suitable for 150 mm dia.borewell suitable for 20 to 80 lpm discharge at 55 to 25 mhead & ( max efficiency at 41 m head & 50 ipm discharge &delivery pipe of necessary diameter with a necessary h. typeclamp as per specification no. wp smppwdele match csr 2021 2022pg no 208 12 2 1 12 item no. 8 : providing & supplying blue m.d.p.e. pipes conforming to iso4427:1996 manufactured from virginresin pe 80 food grade complunded raw materialhaving blue colour only with quality assurance cerificate from quallity agencies like wrc / cipet ( india ) dvgm / kiwa / spgn etc for usage in drinking water system thecost shall include testing fo all materials including all staturotyduties & taxes such as gsr livied by goi & gom in all respect inspection shcarges trandportaiton up to site transitinsurance loading as specified and diretcted unloading stacikg etc complet as specified and directed25mm diamjp dsr 2021 2022 pg no 118 / 1 13 item no. 9 supplying and erecting d.o.l. starter 400v. 3 phase, 50 cycles withno volt coil and overload element with necessary materials andconnected to supply upto 7.5 h.p.pwdele match csr 2021 2022 pg no 21812 4 2 14 item no. 10 supplying and erecting d.o.l. starter 400v. 3 phase, 50 cycles withno volt coil and overload element with necessary materials andconnected to supply upto 10 h.p.pwdele match csr 2021 2022 pg no 218 12 4 3 15 item no. 11providing and fixing following mm diascrewdown bib / stop tap of brass including necessary socketuni on nut complete. pwdssr 2022 2023 pg no 22541.40, 41.42 15 mm dia 16 25 mm dia 17 item no. 12 : providing hand pump cylinder 18 item no. 13 : providing hand pump gi stand assembly 19 item no. 14 : providingwater tank assembly 20 item no. 15: providinggi head assembly 21 item no. 16 : providing gun matel upper valve assembly 22 item no. 17 : providing gun matel lower valve assembly 23 item no. 18 : providing stainless steel plunger rod 24 item no. 19 : providing reducer cap 25 item no. 20 : providing gun matel plunger yoke body 26 item no. 21 : providing upper valve rubber seating ( nitrial rubber ) 27 item no. 22 : providingsealing ring ( nitrial rubber ) 28 item no. 23 : providingpump bucket ( leather ) 29 item no. 24 : providinggunmatel follower ( leather ) 30 item no. 25 : providinggunmatel check valve guide 31 item no. 26 : providinggunmatel check valve seat 32 item no. 27 : providingcylinder body liner ( gunmatel ) for india mark ii 33 item no. 28 : providinggalvanised handle bar 34 item no. 29 : providingstainless steel handle axle 35 item no. 30 : providingskf bearing 6204z 36 item no. 31 : providingrollar chain ( diamond make ) 37 item no. 32 : providinghexagonal bolt galvanized size 12 x 1.75 x 40 mm 38 item no. 33 : providinghexagonal nut galvanized size 12 x 1.75 39 item no. 34 : providinggi washer m 12 4 mm thickness 40 item no. 35: providing hexagonal rod coupling m x 12 x 15 mm ( galvanised ) 41 item no.36: providingconnecting rod 12 mm dia 3 meter length made of bright bar elcetro galvanised fitted with coupler item no. 37 : providinghead for india mark ii 42 item no. 38 : providinggrese ( 2 kg pack ) ...

Directorate Of Municipal Administration - Maharashtra

37548901 annual work for supplying of electrical material for year 2023 24 1 items 2 supplying of electrical material to municipal council, buldana 3 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housing complete. 4 supplying and erecting square / round shaped crca / die cast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13 to18w with provision for plane front frame with translucent cover fixed to the housing complete. 5 supplying and erecting t 5 led tube light complete. 6 supplying pvc armoured cable 4 core 16 sq mm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 7 supplying pvc armoured cable 3 ½core 35sqmm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 8 supplying mains with isi mark wp 2×2.5 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 9 supplying mains with isi mark 1 sq.mm. aluminium pvc insululated wire. 10 supplying mains with isi mark wp2×4 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 11 supplying 3 phase 100 amp with isi mark contactor 12 supplying and erecting quartz electronic time switch having 24 hour dial to work on 250v 50cycle a.c. 13 supplying & erecting approved make 500v 100a porcelain base neutral link complete erected in provided m.s. box with hrc fuse cartridge 500v 100a 14 supplyingcabin fan of a.c. 230 v. 50 cycles 400 mm.sweep complete with necessary brackets for fixing cabin fans, wire etc. 15 supplying regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position. 16 generator servicing and repairing for 25 kva generator. 17 supplying and erecting 12 v / 100ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 18 supplying and erecting split type room airconditioning unit 1 tr 5 star capacity 250v, 50 cycles, a.c. supply having 1 no of air handling unit hi wall / floor mounting type complete at position. 19 suppyling and erecting mcb rating 40 63 amp 20 supplying and erecting isolator rating 40 63 amp 21 supplying and erecting street light panel with contactor , timer , mcb isolator complete ( rating 100 amp ) ...

Directorate Of Sports And Youth Affairs - Maharashtra

37300893 proposed preparation of basketball court at district sports complex latur , work portion ( a ) , excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. ( lift upto 1.5 m. ) by mechanical means , filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. , supplying hard murum / kankar at the road site, including conveying and stacking complete. , supplying soft murum at the road site, including conveying and stacking complete. , providing dry / trap / granite / quartzite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. , providing and laying cast in situ / ready mix cement concrete in m20 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, steel centering, formwork, laying / pumping , compacting, roughening them if special finish is to be provided, finishing uneven and honey combed surface and curing etc. complete. the cement mortar 1:3 plaster is considered for rendering uneven and honey combed surface only. newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. ( wooden centeringwillnotbeallowed. ) , withfullyautomaticmicroprocessorbasedplcwithscadaenabledreversibledrumtypemixer / concretebatch mix plant ( pan mixer ) etc. complete. with fine aggregate ( crushed sand vsi grade ) , providing and fixing in position tmt fe 500 bar reinforcement of various diameters for r.c.c. pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. , providing and laying concrete pipes of i.s.np. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. , providing and laying concrete pipes of i.s.np. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. , providing and constructing brick masonry inspection chamber 90cm x 45cm with r.c.c. raft in b.c. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round g.s.w. pipes, brick masonry, plastering from inside and airtight with 75 mm thick r.c.c. cover medium duty 140 kg etc. complete. , providing and laying in walls / ceilings / floors 20 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 1.63 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and laying in walls / ceilings / floors 25 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 2.49 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and laying in walls / ceilings / floors 32 mm dia. medium grade having embossed as isi mark galvanised iron pipes of 3.20 kilogram / metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti corrosive oil paint, 2 coats complete. including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. , providing and fixing c.p. two way bib cock of approved make continental including necessary sockets / union nut etc. complete. , open graded premix surfacing providing and laying ogc 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with vts , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and seal coat. for bitumen of specified grade using drum mix type hot mix plant with scada, paver and vibratory roller ( over mpm surface ) ( vg 30 bulk bitumen rates are considered to arrive at rates ) , providing bituminous type a liquid seal coat on bituminous surface including supplying all materials and bitumen of specified gradepreparing existing road surface, heating and applying bitumen @ 0.98 kgsqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 mt. etc. complete. ( vg 30 bulk bitumen rates are considered to arrive at rates ) , providing and fixing synthetic and tennis court on black toping surface, before applying synthetic. cleaning the existing surface by water and then apply entire area with one coat of primer and punding and coacked surface are afillingn with binder and then apply resurfaces black and then apply three coat of synthetic, game line marking a fixing tennis pole and net and as directed by engineer incharge rate are including of all taxes and transportation of material to work slope. ( rate sanctioned by s.e vide letter no. osm / pwc / bldg / 4243 dated 29 / 06 / 2016 ) , providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. , providing and fixing crimped with g.i. mesh and size 20 mm x 20 mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel ) , providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per is 4923 yst310 grade produced from iron ore and blast furnacer out etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. , testing charges ( b ) , charges for testing if material in vigilance & quality control laboratory for cement ( standard consistancy fineness, specific gravity, setting time ( initial & final ) compressive strngth, soundness ) , electrical charges ( c ) , supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fgodf / fls 2 , ( cable 4x10 sq.mm. ( 7.2.33 ) supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cblt / cu , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt / bpc , mains 1x2.5 sq.mm. ( 1.3.3 ) supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw , mcb tp 40 a to 63 a ( 5.3.15 ) supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. sw swr / mcb , tpndb ( 5.4.1 ) supplying and erecting triple pole and neutral distribution board ( tpndb ) surface / flush mounted suitable for spmcb of 12 ways on iron / gi frame ( horizontal busbar type ) as per specification no. sw swr / mcbdb , pipe type earthing ( 9.1.4 ) providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , trench ( 16.1.2 ) making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exn ctr , earth plate ( 9.1.3 ) providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. eaep , g.i. pipe ( 7.6.2 ) supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce , add 5% contingencies , add 2% consultant fees , add 18% gst , add 0.1% labour insurance...

Ulhasnagar Municipal Corporation - Maharashtra

37300021 e tender for providing mini highmast in electrical bus transport depo, plot no 1606 to 1620 nr. sai legend world nr. shahad station, ulhasnagar 1 e tender for providing mini highmast in electrical bus transport depo, plot no 1606 to 1620 nr. sai legend world nr. shahad station, ulhasnagar 1 , supplying and erecting led flood light fitting of 200w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminum alloy and heat sink extruded aluminum complete make: polycab / bajaj / wipro ( sample approved in umc ) , providing & erecting 9 m high galvanised conical pole with foundation bolts having bottom dia. from 165 to 200 mm, top dia. from 65 to 75 mm on provided foundation make: bajaj / faryas / volmount / transrail , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) make as per pwd guideline , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the resultsmake: as per ie standard , making the trenchin hard murum / tar road suitable for width and depth for laying cablesmake : as per ie standard specification , making trench of suitable width and depth in hard murum / tar road for laying providedof lt cables of16 sq mm and above and covered with half round hume pipe completed make as per pwd guideline , supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 75 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete make as per pwd guideline , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv make: polycab / pressfit / vishal / finolex , supplying, erecting & terminating xple armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with make: polycab / pressfit / vishal / finolex , supply and erectingroad light box panel manufactured g.i sheet 1.25 ( 18 guage ) box size 30x24x12 deep with wooden planks etc. with road light box clamps for mounting of road lights on msedcl pole with 100 amp , 3 phase tpn main switch and 60 amp porcelain connector with complete wiringmake as per umc approved , supply and erectingtimerbox panel manufactured g.i sheet 1.25 ( 18 guage ) box size 21x19.5x7 deep with wooden planks etc. with 40 amp power contactor 3 nos 63 amp mcb 3 nos almanac digital timer 01 , 60 amp porcelain connector 03 nos etcwith complete wiringmake as per umc approved...

Directorate Of Municipal Administration - Maharashtra

37221150 tender for supply of electric materials for light dept in shrigonda council 2 core 2.5 sqmm aluminium wire bundle ( 90 mtr ) 2 core 4 sqmm aluminium wire bundle ( 90 mtr ) 2 core 6 sqmm aluminium wire bundle ( 90 mtr ) 4 flexible wire per mtr 1 core 1 sqmm coppr wire ( per mtr ) 1 core 1.5 sqmm coppr wire ( per mtr ) 5 6 1 core 2.5 sqmm coppr wire ( per mtr ) 7 3 core 1.5 sqmm copper cable ( per mtr ) 4 core 4 sqmm xlpe armoured aluminium cable ( per mtr ) 8 9 4 core 6 sqmm xlpe armoured aluminium cable ( per mtr ) 4 core 10 sqmm xlpe armoured aluminium cable ( per mtr ) 10 11 12 xlpe armoured cable 4 core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 13 xlpe armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire ( per mtr ) 14 xlpe armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire ( per mtr ) 15 mainswitch 1 phase 32 a 16 mainswitch 1 phase 63 a 17 mainswitch 3 phase 32 a 18 mainswitch 3 phase 63 a 19 mainswitch 3 phase 100 a 20 20 mainswitch 3 phase 200 a 21 mcb spmcb 5a mcb spmcb 6 32a 22 23 mcb tpmcb 6a to 32a 24 mcb tpmcb 40a to 63a mcb fpmcb 6a to 32a 25 mcb fpmcb 40a to 63a 26 contactor 2 pole 32 a 227 contactor 4 pole 16 a 28 contactor 4 pole 40 a ceramic cut out 32a ceramic cut out 63a ceramic cut out 100a ceramic cut out 200a insulation tape per box ( 30 piece in box ) led bulb 5 w 36 led bulb 9 w 317 led bulb 15w 38 88 led bulb 20 w 39 angle holder 40 led tube patti 18 w 41 led tube patti 20 w 42 led tube patti 25 w clamp for rail, cement pole / clani clamp for round pole / clamp. clamp for highmast / clamp bracket for rail round, cement pole 46 6 module switch board 47 12 module switch board 48 18 module switch board 49 6*8 module switch board 50 2 module switch board 51 modular 3 pin 6 a socket 52 modular 3 pin 16 a socket 53 modular 5 pin 6 a socket 54 modular 5 pin 16 a socket 55 56 fan pvc regulator 58 fan step regulator 59 modular switch 6a 60 modular switch 16a 61 bell switch modular 16a 62 dp switch modular 16a 63 dp switch modular 32 a 64 bell switch modular 32a ceiling fan 1200 mm ( copper winding ) 65 ceiling fan 900 mm ( copper winding ) 67 wall fan 400 mm 68 69 standing fan 400 mm fan capacitor 3.15mfd 70 fan capacitor 2.5mfdg 71 dummy plate 72 extension board 73 casing patti per mtr 74 casing pipe 0.5 inch per mtr 75 3 pin plug top 6a 76 3 pin plug top 6a 77 supplying porcelain shackle type lt medium insulator 50 x 89 mm dia. with g.i. ( shackle ) strips, nuts and bolts, complete. 78 supplying aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) per mtr 79 supplying aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) per mtr 80 playwood board 6*4 81 playwood board 8*6 82 aluminium lug 6 mm aluminium lug 16 mm 83 84 copper lug 6 mm 85 copper lug 16 mm 86 male female pin 87 pvc clamp pocket 88 upto 25w led driver 89 upto 25w led plate 90 upto 25w led spd 91 26 45w led driver 92 26 45w led plate 93 26 45w led spd 94 46 75w led driver 95 46 75w led plate 96 96 46 75w led spd 97 office bell 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe ( per mtr ) 98 99 24 hrs digital / astronomical timer for street light control panel...

Reserve Bank Of India - Maharashtra

37200165 dismantling carefully removing all distribution boards, fans, light fittings, decorative lights, geysers, water purifier, wires, conduits, casing capping switch boards, telephone sets etc. provided in the flat and keeping reusable items in safe place as instructed / directed by bank?s engineer. 2 2 sitc of mcb db supply, installation testing and commissioning of single phase 12 way mcb d.b. metallic double door ( factory fabricated ) , in concealed manner of approved make, all termination of wires with lugs with crimping etc incomer 40 amp dp rccb ( 30 ma ) 1 no. outgoing 20 amp sp mcb 5 no. 10 amp sp mcb 5 no. blank plates as required, mcbs with 10 ka breaking capacity & c curves, with all accessories and interconnections as instructed by bank?s engineer. 3 3 wiring for light point supply, laying, installation, testing & commissioning wiring for light points using three runs of 1.5 sq mm, 1100 volt grade fire resistant low smoke ( frls ) pvc insulated stranded copper conductor wire ( neutral, and earth in looping system ) to respective point outlet ( inclusive of circuit wiring using three runs of 2.5 sq mm 1100 volts grade stranded copper conductor pvc insulated fire resistant low smoke frls wire from mcb db to respective switchboard ) partly in surface with heavy duty required size of casing , capping for ceiling , beam points & partly in rigid heavy duty pvc conduit of required size with all accessories, to be laid in concealed manner after a chase made in wall including mending good the damages as original finish manner with all accessories like coupler, bend, long bend, tee, junction box, required hardware materials etc as directed, .. for complete details refer tender document. 4 4 wiring for ceiling fan point same as item no. 03 above, but for ceiling fan point along with supply and fixing of electronic 5 step 120 w type fan regulators as approved by banks engineer, socket type with speed marks, modular type of approved make with 10 amp modular switch as specified in item no 03 and complete with interconnection etc 5 5 wiring for 10 amp plug point independent wiring for independent 10 amps plug point with 3 x 2.5 sq mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no.03 above, along with 10 amp modular switch, and shutter type socket ( 2 pin+ 3 pin ) mounted separately on suitable size heavy duty gi box for concealed. these 10 amps points are to be extended from main switch boards provided in respective room as directed by banks engineer 6 6 wiring for half point on control switch board same as item no. 03 above, but for supply, fixing providing ( half point ) wiring for 10 amp. universal socket ( 2 pin + 3 pin ) and switch modular type to be fixed on same switch board used for light / fan / plug point. 7 7 wiring for computer point same as item no.03 with 3x2.5 sq.mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner but for computer point consisting of 3 no.s 10a 3 / 5 pin socket controlled by 3 no 10a modular switch fixed with suitable size heavy duty gi box for concealed with pvc board for surface as specified in item no.03 above. a separate conduit to be taken from mcb db with separate earth wire. 8 8 wiring for call bell point wiring for bell point as per item no 03 above, but with 10 amp modular bell push to be fixed in concealed manner with control off switch on switchboard provided in the flat along with supply and fixing of ding dong bell of approved make with hardware materials, as approved by banks engineer. 9 9 wiring for 2 switch 2 socket point for tv same as item no.5 above but for 10 amps 3 pin modular sockets 2 nos. controlled by 10 amps modular switches 2 nos. 10 10 wiring for 20 amp plug point ? independent wiring for independent 20 amps plug point with 2.5 sq. mm x 3 runs multi stranded copper conductor frls wire ( from mcbdb to plug point ) for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no 03 above, along with 20 amp modular switch, and shutter type 10 / 20 socket mounted separately on suitable size heavy duty gi box concealed with pvc board on surface along with covers of approved. 11 11 telephone wiring wiring for 03 nos. telephone sockets rj 11 outlet with shutter as per item no. 03 using two pair 0.5 mm dia tinned copper pvc insulated wire from common point in staircase to drawing cum dining room of individual flat and further looping to another point ( each bedroom ) , separate conduit to be laid for tel / cable tv wires, using all accessories as per item no. 03 ( separate conduit is to be laid up to common point in staircase ) as directed by bank?s engineer rate includes supply, laying, terminating etc. of telephone socket and wire, complete in all respect. ? drawing room: 01 nos. socket ? bedroom 1: 01 nos socket ? bedroom 2: 01 nos socket 12 12 cable tv wiring wiring for cable tv point with rj6 cable tv wire laying from cable tv operator junction box installed in the staircase up to first point in the drawing room making the parallel connection in the bed room gi with same wire rj6 cable tv wire along with modular type tv socket all in concealed manner ? drawing room: 01 nos. ? bedroom 1: 01 nos ? bedroom 2: 01 nos 13 13 ceiling fans supply, installation, testing and commissioning of 1200 mm, 3 blade new ceiling fan with all necessary mounting accessories. hall bedroom 1, bedroom 2 14 14 ceiling fans supply, installation, testing and commissioning of 600 mm, 4 blade new ceiling fan with all necessary mounting accessories. kitchen 15 15 tube light fittings supply, installation, testing and commissioning of tube light fixtures 20 / 22 w led tube light using 2 core flexible 0.5 sq mm. flat pvc insulated white copper wire with adaptor complete with all accessories, to be mounted on pvc square block as per instructions of bank?s engineer. 16 16 exhaust fan supply, fixing , testing & installation of approved make? 250 mm dia high speed exhaust fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in kitchen as per site condition complete in all respect. kitchen 17 17 exhaust fan supply, fixing , testing & installation of orient / crompton make? 200 mm dia high speed fresh air fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in wc as per site condition complete in all respect. toilet and bathroom 18 18 rebate item rebate for taking away all unusable items like wires / switches / switchboards / db?s removed under item no 01 ( per flat ) 19 19 cgst cgst amount per flat 20 20 sgst sgst amount per flat...

Tata Memorial Centre - Maharashtra

37174900 item rate running contract for annual electrical works and supply of electrical items for the year 2023 24 at actrec 1 point wiring 1.1 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.2 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing thepoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable etc. as required. 1.3 primary point wiring as 1.1 , modular 2 module fan regulator 250w 1.4 sitc wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvcinsulated copper conductor single core cable etc. as required. 1.5 sitc of wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.6 sitc of secondary light point from first light point to second light point connected in the same switch ie looping point with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. 1.7 primary point wiring as per 1.5 modular 2 module fan regulator 250w 1.8 sitc of wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5sq.mm frls pvc insulated copper conductor single core cableetc. as required. 2.1 fan hookfabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only supply ) 2.2 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( only labour ) 2.3 fabrication, supply & fixing of ms fan hook box having 2 coats of red oxide finish made out of 16 mm rod & fixing in ceiling with anchor fastner including digging, cementing, plastering, finishing it to match with the background complete in all respects ( composite ) 2.4 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only supply ) 2.5 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners. complete in all respects ( only labour ) 2.6 fabrication, supply & fixing of ms fan hook made out of 16 mm rod & fixing in ceiling using double anchor fasteners complete in all respects. ( composite ) 2.7 supply of fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( only supply ) 2.8 fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18 inch long etc. complete in all respect. ( only labour ) 2.9 supply & fixing fan down rod made out of gi conduit pipes of 20 mm or suitable with threading, boring etc. complete up to 18inch long etc. complete in all respect. ( composite ) 3 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed steel conduit as required. 3.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 3.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 3.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 3.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 3.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 3.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 3.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 3.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 3.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 3.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 4 wiring for circuit / submain wiring alongwith earth wire with thefollowing sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. 4.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 4.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 4.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 4.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 4.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 4.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 4.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 4.8 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 4.9 4 x 6 sq. mm + 2 x 6 sq. mm earth wire 4.11 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 4.12 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 6.1 supply & fixing of casing capping of following suitable size with screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. complete as per instructions of eic. 6.1.1 half inch ( only supply ) 6.1.2 half inch ( only labour ) 6.1.3 half inch ( composite ) 6.1.4 threefouth inch ( only supply ) 6.1.5 threefouth inch ( only labour ) 6.1.6 threefouth inch ( composite ) 6.1.7 1inch ( only supply ) 6.1.8 1inch ( only labour ) 6.1.9 1inch ( composite ) 6.1.10 1.25inch ( only supply ) 6.1.11 1.25inch ( only labour ) 6.1.12 1.25inch ( composite ) 6.1.13 1.50inch ( only supply ) 6.1.14 1.50inch ( only labour ) 6.1.15 1.50inch ( composite ) 6.1.16 2.0 inch ( only supply ) 6.1.17 2.0 inch ( only labour ) 6.1.18 2.0 inch ( composite ) 7.1 fixing of pvc conduit / truncking. supply & fixing of pvc rigid conduit of following suitable size with spacers & saddles screws, rawal plug etc. along with all accessories complete in all respect on any hard surface / wall / trench / ceiling etc. compete as per instruction of eic. 7.1.1 12.5 mm ( only supply ) 7.1.2 12.5 mm ( only labour ) 7.1.3 12.5 mm ( composite ) 7.1.4 20 mm ( only supply ) 7.1.5 20 mm ( only labour ) 7.1.6 20 mm ( composite ) 7.1.7 25 mm ( only supply ) 7.1.8 25 mm ( only labour ) 7.1.9 25 mm ( composite ) 7.1.10 32 mm ( only supply ) 7.1.11 32 mm ( only labour ) 7.1.12 32 mm ( composite ) 7.1.13 40 mm ( only supply ) 7.1.14 40 mm ( only labour ) 7.1.15 40 mm ( composite ) 7.1.16 50 mm ( only supply ) 7.1.17 50 mm ( only labour ) 7.1.18 50 mm ( composite ) 7.2 providing & fixing pvc trucking of following sizes along with all accessories complete in all respect, all as directed by o i c, es. 7.2.1 50 x 50 x 2 mm ( only supply ) 7.2.2 50 x 50 x 2 mm ( only labour ) 7.2.3 50 x 50 x 2 mm ( composite ) 7.2.4 100 x 50 x 2 mm ( only supply ) 7.2.5 100 x 50 x 2 mm ( only labour ) 7.2.6 100 x 50 x 2 mm ( composite ) 8.1 laying of bunch of wires. supplying & pulling wires with 1.5 sq. mm solid / stranded copper insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.1.1 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.2 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.3 same as item no 8.1 but for 2 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.4 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.5 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.6 same as item no 8.1 but for 3 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.7 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.8 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.9 same as item no 8.1 but for 4 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.10 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.11 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.12 same as item no 8.1 but for 5 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.1.13 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.1.14 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.1.15 same as item no 8.1 but for 6 x 1.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2 supplying & pulling wires with 2.5 sq. mm solid / stranded copper pvc insulated wire with kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.2.1 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark. ( only supply ) 8.2.2 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( only labour ) 8.2.3 same as item no 8.2 but for 2 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with mark.. ( composite ) 8.2.4 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.5 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.6 same as item no 8.2 but for 3 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.7 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.8 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.9 same as item no 8.2 but for 4 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.10 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.11 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.12 same as item no 8.2 but for 5 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.2.13 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.2.14 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.2.15 same as item no 8.2 but for 6 x 2.5 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( composite ) 8.3 supplying & pulling wires with 4 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.3.1 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.2 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.3 same as item no 8.3 but for 2 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.4 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.5 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.6 same as item no 8.3 but for 3 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.7 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.8 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.9 same as item no 8.3 but for 4 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.10 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.11 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.12 same as item no 8.3 but for 5 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.3.13 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.3.14 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only labour ) 8.3.15 same as item no 8.3 but for 6 x 4 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4 supplying & pulling wires with 6 sq. mm solid / stranded copper pvc insulated wire with 1.1 kv grade with isi mark laid in conduit / casing capping inside bus bars / switches etc, with necessary bakelite / rubber bushings / sleeves & connected to apparatus in an approved manner with bottle type / nut type cable terminals of adequate capacity. 8.4.1 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.2 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.3 same as item no 8.4 but for 2 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.4 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.5 same as item no 8.4 but for 3 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.6 same as item no 8.4 but for 3x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.7 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.8 same as item no 8.4 but for 4 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.9 same as item no 8.4 but for 4x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.10 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.11 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.12 same as item no 8.4 but for 5 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 8.4.13 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( only supply ) 8.4.14 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark.. ( only labour ) 8.4.15 same as item no 8.4 but for 6 x 6 sq. mm copper pvc insulated wire of 1.1 kv grade with isi mark. ( composite ) 9.1 concealing of pipe supplying & laying isi mark ms pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.1.1 same as item no 9.1 but for 20 mm size ( only supply ) 9.1.2 same as item no 9.1 but for 20 mm size ( only labour ) 9.1.3 same as item no 9.1 but for 20 mm size ( composite ) 9.1.4 same as item no 9.1 but for 25 mm size ( only supply ) 9.1.5 same as item no 9.1 but for 25 mm size ( only labour ) 9.1.6 same as item no 9.1 but for 25 mm sizee ( composite ) 9.1.7 same as item no 9.1 but for 32 mm size ( only supply ) 9.1.8 same as item no 9.1 but for 32 mm size ( only labour ) 9.1.9 same as item no 9.1 but for 32 mm sizee ( composite ) 9.2 supplying & laying isi mark gi pipe b class suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.2.1 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only supply ) 9.2.2 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( only labour ) 9.2.3 same as item no 9.2 but isi mark gi conduit 14 swg 20 mm dia. ( composite ) 9.2.4 same as item no 9.2, 25 mm dia gi same as above ( only supply ) 9.2.5 same as item no 9.2, 25 mm dia gisame as above ( only labour ) 9.2.6 same as item no 9.2, 25 mm dia gisame as above ( composite ) 9.2.7 same as item no 9.2, 32 mm diagi same as above ( only supply ) 9.2.8 same as item no 9.2, 32 mm diagi same as above ( only labour ) 9.2.9 same as item no 9.2, 32 mm diagi same as above ( composite ) 9.3 supplying & laying isi mark pvc rigid pipe of suitable size dia with necessary bends, tees & junction boxes with check nuts etc in wall or ceiling with making groves & plastering with cement mortar & finishing the surface to match the back ground in r.c.c. slab / bricks wall etc with continuous 14 swg tinned bare copper wire as earth wire erected with copper earth clips of 22 swg 10 mm at the end of every threaded piece to make the pipe electrically continuous in approved manner. complete all as per instruction of eic. 9.3.1 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only supply ) 9.3.2 same as item no 9.3 but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( only labour ) 9.3.3 same as item no 9.3 as above but rigid pvc conduit with isi mark ( is 9537 part 3 ) 20 mm dia heavy gauge same as above ( composite ) 9.3.4 same as item no 9.3 but 25 mm dia pvc conduit ( only supply ) 9.3.5 same as item no 9.3 but 25 mm dia pvc conduit ( only labour ) 9.3.6 same as item no 9.3 but 25 mm dia pvc conduit ( composite ) 9.3.7 same as item no 9.3but 32 mm dia pvc conduit ( only supply ) 9.3.8 same as item no 9.3but 32 mm dia pvc conduit ( only labour ) 9.3.9 same as item no 9.3but 32 mm dia pvc conduit ( composite ) 9.4 in general same as item no 9.3 but as applicable for concealing the pipes in marble / granite flooring or wall, of following suitable sizes. 9.4.1 20 mm dia ( only supply ) 9.4.2 20 mm dia ( only labour ) 9.4.3 20 mm dia ( composite ) 9.4.4 25 mm dia ( only supply ) 9.4.5 25 mm dia ( only labour ) 9.4.6 25 mm dia ( composite ) 9.4.7 32 mm dia ( only supply ) 9.4.8 32 mm dia ( only labour ) 9.4.9 32 mm dia ( composite ) 9.4.10 38 mm dia ( only supply ) 9.4.11 38 mm dia ( only labour ) 9.4.12 38 mm dia ( composite ) 10.1 area lighting fittings covers supply fixing / replacement of glass / acrylic covers for various street light / flood light / area lighting or any such lighting fittings having same grade of glass / acrylic all as directed by o i c, es. agency is requested to see the sample first and adequate / suitable replacement sall be done. removed covers / parts shall be returned to actrec as it is. 10.1.1 for post top lantern ( only supply ) 10.1.2 for post top lantern ( only labour ) 10.1.3 for post top lantern ( composite ) 10.1.4 any other equivalent for item no 10.1 application but non standred lighting fixture ( only supply ) 10.1.5 any other equivalent for item no 10.1 application but non standred lighting fixture ( only labour ) 10.1.6 any other equivalent but for item no 10.1 appplication non standred lighting fixture ( composite ) 11.1 pvc flexible conduit supply & laying / replacement of pvc flexible conduit conforming to isi standards & approved make with required number of coupling, pvc bushes, check nuts etc complete all as per instruction of eic. in case of replacement, removed parts, items etc. shall be returned to actrec as it is. 11.1.1 same as above 20 mm dia same as above ( only supply ) 11.1.2 same as above 20 mm diasame as above ( only labour ) 11.1.3 same as above20 mm dia same as above ( composite ) 11.1.4 same as above 25 mm dia same as above ( only supply ) 11.1.5 same as above 25 mm dia same as above ( only labour ) 11.1.6 same as above 25 mm dia same as above ( composite ) 11.1.7 same as above 32 mm dia same as above ( only supply ) 11.1.8 same as above 32 mm dia same as above ( only labour ) 11.1.9 same as above 32 mm dia same as above ( composite ) 11.1.10 same as above 40 mm dia same as above ( only supply ) 11.1.11 same as above 40 mm dia same as above ( only labour ) 11.1.12 same as above 40 mm dia same as above ( composite ) 11.1.13 same as above 50 mm dia same as above ( only supply ) 11.1.14 same as above 50 mm dia same as above ( only labour ) 11.1.15 same as above 50 mm dia same as above ( composite ) 12.1 dismentling dismantling / removing the existing light, fan, bell, independent plug point, wiring of all types with accessories, switch boards etc to the satisfaction of in charge. all dismantled / removed / scrap material to be handed over to engg. dept as it is. ( only labour ) 12.2 dismantling the existing mains wires of all sizes, make running through pvc casing capping / pipes / ms conduits including casing capping / pvc pipes / ms pipes / gi pipes / hgdwc pipes / pvc or metal trunking etc. ( only labour ) 12.3 dismantling the cables of following sizes without damaging it with glands, cable end boxes, earthing, saddles, spacers & clamps etc & cleaning the surface area & hand over to engg. in –charge. ( only labour ) 12.3.1 1.5 sq. mm to 10 sq. mm ( only labour ) 12.3.2 16 sq. mm to 70 sq. mm ( only labour ) 12.3.3 above 70 sq. mm ( only labour ) 12.4 dismantling of distribution board / bus bar irrespective of size, capacity / ways etc complete with angle iron frame & making the site clear by refilling the holes etc. & finishing matching to background and handing over it to actrec as it is. ( only labour ) 12.5 dismantling ceiling fan, exhaust fan, wall / cabin fan / fluorescent lamp / night lamp etc. with accessories, gi down rod, frame etc & making the site clear & finishing matching to background and handing over the items to actrec as it is. ( only labour ) 12.6 dismantling existing electric geyser / storage type water heater irrespective of size, make, including brackets, grouting bolts etc refilling the holes with cement mortar & making the site clear and handing over it to actre as it is. ( only labour ) 12.7 dismantling of smoke detector / response indicator / bg / circuit isolator / ahu cut off, putting insulation on exposed ends etc and handing nover it t actrec as it is. ( only labour ) 13.1 rewinding rewinding of table / wall / pedestal / exhaust fan up to 300 mm / dip freezer / any similar application motor etc. of all types & make including overhauling, minor repairs, testing for the original speed including transportation, removal from point of fault & refiitting of the same after repairs for inclusive cost as mentioned in the following item nos. all the items removed while repairs / replacements except copper coils shall be handed over / returned to e i c as it is. ( composite ) 13.2 all general gidelines as per item no 13.1 but for rewinding of exhaust fan above sweep 300 mm. ( composite ) 13.3 all general guide lines as per item no 13.1 but for rewinding of ceiling fan motor of all makes and types including overhauling, including minor repairs, & testing at site of following sizes. all the removed / replaced parts / items shall be returned / handed over to e i c, es. 13.3.1 900 mm sweep ( composite ) 13.3.2 1200 mm sweep ( composite ) 13.3.3 1400 mm sweep ( composite ) 13.4 rewinding of single / three phase motors rewinding of electric single phase / three phase motors not covered in item no 13.1 and 13.3, winding with copper wire, overhauling with minor repairs along with the replacement of minor parts, testing for the original speed & guarantee of minimum 6 months, having heneral guidelines as per itam no 13.1 and 13.3, allas per the instructions of e i c, es for inclusive cost as mentioned in the folloeing various items nos. 13.4.1 motors up to onefourth hp single phase. ( composite ) 13.4.2 motors up to half hp single phase. ( composite ) 13.4.3 1 hp single phase. ( composite ) 13.4.4 2 hp single phase ( composite ) 13.4.5 single phase 3 hp ( composite ) 13.4.6 up to 1 hp 3 phase ( composite ) 13.4.7 2 hp 3 phase ( composite ) 13.4.8 3 hp 3 phase ( composite ) 13.4.9 5 hp 3 phase ( composite ) 13.4.10 7.5 hp 3 phase ( composite ) 13.4.11 10 hp 3 phase ( composite ) 13.4.12 12.5 hp 3 phase ( composite ) 13.4.13 15 hp 3 phase ( composite ) 13.4.14 20 hp 3 phase ( composite ) 13.4.15 25 hp 3 phase ( composite ) 13.4.16 30 hp 3 phase ( composite ) 13.4.17 40 hp 3 phase ( composite ) 13.4.18 45 hp 3 phase ( composite ) 13.4.19 50 hp 3 phase ( composite ) 13.4.20 60 hp 3 phase ( composite ) 13.4.21 5 hp submersible pump, 3 ph. ( composite ) 13.4.22 3 hp submersible pump 3 ph ( composite ) 13.4.23 2 hp submersible pump 3 ph ( composite ) 13.4.24 2 hp submersible pump 1 ph ( composite ) 14.1 bearings replacing the worn out / unservicible existing ball of approved make of single phase three phase electric motor / other relevent applications of all types with proper alignment of shaft, greasing / oiling etc & testing at site sll as per the instructions of e i c, es. removed / replaced bearings shall be handed over to e i c, es as it is. ( gate pass / challans are to te submitted to e i c, es each time ) 14.1.1 2 hp to 3 hp ( only supply ) 14.1.2 2 hp to 3 hp ( only labour ) 14.1.3 2 hp to 3 hp ( composite ) 14.1.4 4 hp to 7.5 hp ( only supply ) 14.1.5 4 hp to 7.5 hp ( only labour ) 14.1.6 4 hp to 7.5 hp ( composite ) 14.1.7 10 hp to 20 hp ( only supply ) 14.1.8 10 hp to 20 hp ( only labour ) 14.1.9 10 hp to 20 hp ( composite ) 14.1.10 25 hp to 30 hp ( only supply ) 14.1.11 25 hp to 30 hp ( only labour ) 14.1.12 25 hp to 30 hp ( composite ) 14.1.13 35 hp to 40 hp ( only supply ) 14.1.14 35 hp to 40 hp ( only labour ) 14.1.15 35 hp to 40 hp ( composite ) 14.1.16 45 hp to 50 hp ( only supply ) 14.1.17 45 hp to 50 hp ( only labour ) 14.1.18 45 hp to 50 hp ( composite ) 14.1.19 60 hp to 75 hp ( only supply ) 14.1.20 60 hp to 75 hp ( only labour ) 14.1.21 60 hp to 75 hp ( composite ) 14.2 bearings / bushings / rotors 14.2.1 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only supply ) 14.2.2 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site.refer guidelines as per item no 14.1 ( only labour ) 14.2.3 replacing the worn out existing ball bearing of table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor complete with alignment of shaft & testing at site. refer guidelines as per item no 14.1 ( composite ) 14.2.4 replacement of shaft for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc ( only labour ) refer guidelines as per item no 14.1 as applicable for this item. 14.2.5 replacement of wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc.refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.6 replacement of non wound rotor for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. 14.2.7 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( only supply ) 14.2.8 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item ( only labour ) 14.2.9 replacement of bushing for table fan / wall fan / pedestal fan / ceiling fan / exhaust fan / dip freezer or any similar application motor etc. refer guidelines as per item no 14.1 as applicable for this item. ( composite ) 14.2.10 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only supply ) 14.2.11 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( only labour ) 14.2.12 varnish of good quality for general motor maintenance etc with prior approval. ( not applicable as a part of rewinding etc. this item will be run only when application will be done exclusively ( composite ) 14.2.13 painting of old fans, tube lights fixtures, motors or anyh other such application etc as decided and directed by e i c, es with enamel paint after coat of red oxide etc. ( note: this item is applicable only when specifically required for small / midium size erquipment coverd in section no 14. painting included in overhauling or repairs of any electrical equipment / instrument / machine does not come under this. ) ( composite ) 14.2.14 repairing of domestic mixer / grinder / blender or any other eqvuivalant domestic applience etc that includes replacement of indicators, switches, couplers, oiling, general servicing, or any other relvant spare part etc for all manufactures, all as per instructions of engineer in charge. replaced material shall be brought back & shall be submitted to e i c, whereever applicable ( composite ) . 14.2.15 all as per item no 14.2.14 but for replacement of bearing / bushings / blades etc. ( composite ) 14.2.16 all general guidelines as per item no 14.2.14 but for tea kettle excluding heating coil. ( composite ) 14.2.17 replacement of pump impeller ( composite ) 14.2.18 replacement of impeller for 3 hp pump ( composite ) 14.2.19 replacement of impeller for 5 hp pump ( composite ) 14.2.20 replacement of cooling fan for motor up to 2hp. 14.3 capacitors 14.3.1 replacing the defective capacitor of table fan / wall fan / pedestal fan / ceiling fan / dip freezer motor / street light fittings / fluorescent tube fittings or any other smilar application etc & testing at site. general guidelines for replacement shall be as per item no 14.1 as applicable, all as per instructions and as directed by e i c, es 14.3.1.1 1.5 mfd ( only supply ) 14.3.1.2 1.5 mfd ( only labour ) 14.3.1.3 1.5 mfd ( composite ) 14.3.1.4 2.5 mfd ( only supply ) 14.3.1.5 2.5 mfd ( only labour ) 14.3.1.6 2.5 mfd ( composite ) 14.3.1.7 4 mfd ( only supply ) 14.3.1.8 4 mfd ( only labour ) 14.3.1.9 4 mfd ( composite ) 14.3.1.10 5 / 6 mfd ( only supply ) 14.3.1.11 5 / 6 mfd ( only labour ) 14.3.1.12 5 / 6 mfd ( composite ) 14.3.1.13 10 / 15 mfd ( only supply ) 14.3.1.14 10 / 15 mfd ( only labour ) 14.3.1.15 10 / 15 mfd ( composite ) 14.3.1.16 20 mfd ( only supply ) 14.3.1.17 20 mfd ( only labour ) 14.3.1.18 20 mfd ( composite ) 14.3.1.19 33 mfd ( only supply ) 14.3.1.20 33 mfd ( only labour ) 14.3.1.21 33 mfd ( composite ) 14.3.1.22 40 mfd ( only supply ) 14.3.1.23 40 mfd ( only labour ) 14.3.1.24 40 mfd ( composite ) 14.3.1.25 60 mfd ( only supply ) 14.3.1.26 60 mfd ( only labour ) 14.3.1.27 60 mfd ( composite ) 14.3.1.28 80 mfd ( only supply ) 14.3.1.29 80 mfd ( only labour ) 14.3.1.30 80 mfd ( composite ) 14.3.1.31 120 mfd ( only supply ) 14.3.1.32 120 mfd ( only labour ) 14.3.1.33 120 mfd ( composite ) 14.3.1.34 200 mfd ( only supply ) 14.3.1.35 200 mfd ( only labour ) 14.3.1.36 200 mfd ( composite ) 14.4 coils / transformers 14.4.1 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) ( only supply ) 14.4.2 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es. ( only labour ) 14.4.3 supply & replacement of 240 v / 440 v no volt coil / contactor coils of any make motor starter for any capacity ( l & t / siemens make or equivalent ) removed / replaced parts are to be handed over to e i c, es ( composite ) . 14.4.4 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or any such other specific circuits / appplications. prior approval is required. ( only supply ) 14.4.5 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( only labour ) . 14.4.6 supply & replacement of 240 v / 440 v transformer coils of any make for any capacity for emergency light or ant other specific circuits. prior approval is required. removed / replaced parts are to be handed over to e i c, es ( composite ) . 15.1 olr / starters / terminal boxes supply & replacement of thermal over load relay for motors or any other such application as decided by e i c, es including lugging, putting insulation tape ets. in case of replacement, removed / replaced parts shall be handed over to e i c, es along with gatepass / challans etc. 15.1.1 up to 7.5 hp ( only supply ) 15.1.2 up to 7.5 hp ( only labour ) 15.1.3 up to 7.5 hp ( composite ) 15.1.4 10 hp to 20 hp ( only supply ) 15.1.5 10 hp to 20 hp ( only labour ) 15.1.6 10 hp to 20 hp ( composite ) 15.1.7 25 hp to 30 hp ( only supply ) 15.1.8 25 hp to 30 hp ( only labour ) 15.1.9 25 hp to 30 hp ( composite ) 15.1.10 35 hp to 40 hp ( only supply ) 15.1.11 35 hp to 40 hp ( only labour ) 15.1.12 35 hp to 40 hp ( composite ) 15.1.13 45 hp to 50 hp ( only supply ) 15.1.14 45 hp to 50 hp ( only labour ) 15.1.15 45 hp to 50 hp ( composite ) 15.1.16 60 hp to 75 hp ( only supply ) 15.1.17 60 hp to 75 hp ( only labour ) 15.1.18 60 hp to 75 hp ( composite ) 15.2 supply, installation, testing & commissioning of dol starters, of reputed make make as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic. in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.2.1 up to 2 hp / 1.5 kw single phase. ( only supply ) 15.2.2 up to 2 hp / 1.5 kw single phase. ( only labour ) 15.2.3 up to 2 hp / 1.5 kw single phase. ( composite ) 15.2.4 up to 7.5 hp / 5.5 kw 3phase. ( only supply ) 15.2.5 up to 7.5 hp / 5.5 kw 3phase. ( only labour ) 15.2.6 up to 7.5 hp / 5.5 kw 3phase. ( composite ) 15.2.7 up to 10 hp ( only supply ) 15.2.8 up to 10 hp ( only labour ) 15.2.9 up to 10 hp ( composite ) 15.2.10 up to 20 hp, ( only supply ) 15.2.11 up to 20 hp, ( only labour ) 15.2.12 up to 20 hp, ( composite ) 15.2.13 for 30 hp. ( only supply ) 15.2.14 for 30 hp. ( only labour ) 15.2.15 for 30 hp. ( composite ) 15.2.16 for 40 hp. ( only supply ) 15.2.17 for 40 hp. ( only labour ) 15.2.18 for 40 hp. ( composite ) 15.3 supply, installation, testing & commissioning of fully automatic star delta motor starters, as per the required capacity listed below with framework including connection with lugs etc. complete in all manners as per instruction of eic.in case of replacement removed parts shall be handed pver to e i c, es along with gatepass / challans. 15.3.1 up to 2 hp ( only supply ) 15.3.2 up to 2 hp ( only labour ) 15.3.3 up to 2 hp ( composite ) 15.3.4 up to 5 hp ( only supply ) 15.3.5 up to 5 hp ( only labour ) 15.3.6 up to 5 hp ( composite ) 15.3.7 up to 10 hp ( only supply ) 15.3.8 up to 10 hp ( only labour ) 15.3.9 up to 10 hp ( composite ) 15.3.10 up to 12.5 hp ( only supply ) 15.3.11 up to 12.5 hp ( only labour ) 15.3.12 up to 12.5 hp ( composite ) 15.3.13 up to 15 hp ( only supply ) 15.3.14 up to 15 hp ( only labour ) 15.3.15 up to 15 hp ( composite ) 15.3.16 up to 20 hp ( only supply ) 15.3.17 up to 20 hp ( only labour ) 15.3.18 up to 20 hp ( composite ) 15.3.19 up to 30 hp ( only supply ) 15.3.20 up to 30 hp ( only labour ) 15.3.21 up to 30 hp ( composite ) 15.3.22 up to 50 hp ( only supply ) 15.3.23 up to 50 hp ( only labour ) 15.3.24 up to 50 hp ( composite ) 15.3.25 up to 75 hp ( only supply ) 15.3.26 up to 75 hp ( only labour ) 15.3.27 up to 75 hp ( composite ) 15.3.28 providing & fixing of motor terminal boxes. up to 1 hp ( only supply ) 15.3.29 up to 1 hp ( only labour ) 15.3.30 up to 1 hp ( composite ) 15.3.31 up to 2 hp ( only supply ) 15.3.32 up to 2 hp ( only labour ) 15.3.33 up to 2 hp ( composite ) 15.3.34 up to 5 hp ( only supply ) 15.3.35 up to 5 hp ( only labour ) 15.3.36 up to 5 hp ( composite ) 15.3.37 up to 10 hp ( only supply ) 15.3.38 up to 10 hp ( only labour ) 15.3.39 up to 10 hp ( composite ) 15.3.40 up to 20 hp ( only supply ) 15.3.41 up to 20 hp ( only labour ) 15.3.42 up to 20 hp ( composite ) 15.3.43 up to 30 hp ( only supply ) 15.3.44 up to 30 hp ( only labour ) 15.3.45 up to 30 hp ( composite ) 15.3.46 up to 50 hp ( only supply ) 15.3.47 up to 50 hp ( only labour ) 15.3.48 up to 50 hp ( composite ) 15.3.49 up to 75 hp ( only supply ) 15.3.50 up to 75 hp ( only labour ) 15.3.51 up to 75 hp ( composite ) 16.1 registers / discharge registers register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 18030. ( only supply ) 16.2 register, kiyosh make, 10 kohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( only labour ) 16.3 register, kiyosh make, 10 k ohm ± 5 perc., 15 w, 9624, cop 15, 18030. ( composite ) 16.4 discharge resistors for capacitor banks up to 100 kvar ( only supply ) 17.1 supply, installing of electrical consumable items with testing & commissioning of them as specifications & as per direction of engg in charge.in case of replacement / repairs, old materials shall be handed over to e i c, es along with gatepass / challans etc. all replacements are subjected to prior approval of o i c, es for any equivalent make, if make is not mentioned. ( kindly refer make list provided separately ) . it may be noted that minimum balance of these itmes are required to maintain on site for emerrgency use. 17.1.1 40 w fluorescent tube reputed make ( only supply ) 17.1.2 40 w fluorescent tube reputed make ( only labour ) 17.1.3 40 w fluorescent tube reputed make ( composite ) 17.1.4 36 w fluorescent tube reputed make ( only supply ) 17.1.5 36 w fluorescent tube reputed make ( only labour ) 17.1.6 36 w fluorescent tube reputed make ( composite ) 17.1.7 20 w fluorescent tube reputed make ( only supply ) 17.1.8 20 w fluorescent tube reputed make ( only labour ) 17.1.9 20 w fluorescent tube reputed make ( composite ) 17.1.10 18 w fluorescent tube reputed make ( only supply ) 17.1.11 18 w fluorescent tube reputed make ( only labour ) 17.1.12 18 w fluorescent tube reputed make ( composite ) 17.1.13 9 w pl s fluorescent tube reputed make ( only supply ) 17.1.14 9 w pl s fluorescent tube reputed make ( only labour ) 17.1.15 9 w pl s fluorescent tube reputed make ( composite ) 17.1.16 11 w pl s fluorescent tube reputed make ( only supply ) 17.1.17 11 w pl s fluorescent tube reputed make ( only labour ) 17.1.18 11 w pl s fluorescent tube reputed make ( composite ) 17.1.19 75 w comptalux lamp of reputed make ( only supply ) 17.1.20 75 w comptalux lamp of reputed make ( only labour ) 17.1.21 75 w comptalux lamp of reputed make ( composite ) 17.1.22 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only supply ) 17.1.23 30 w germicidal fluorescent ulitrea violet tube of reputed make ( only labour ) 17.1.24 30 w germicidal fluorescent ulitrea violet tube of reputed make ( composite ) 17.1.25 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only supply ) 17.1.26 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( only labour ) 17.1.27 36 w germicidal fluorescent ulitrea violet light fixture with tube 4 feet ( composite ) 17.1.28 same as item no 17.1.22 but 2 or one and the half feet in length ( only supply ) 17.1.29 same as item no 17.1.22 but 2 or one and the half feet in length ( only labour ) 17.1.30 same as item no 17.1.22 but 2 or one and the half feet in length ( only composite ) 17.1.31 insect killer tube size 2 feet ( only supply ) 17.1.32 insect killer tube size 2 feet ( only labour ) 17.1.33 insect killer tube size 2 feet ( composite ) 17.1.34 insect killer tube size one and the half feet ( only supply ) 17.1.35 insect killer tube size one and the half feet ( only labour ) 17.1.36 insect killer tube size one and the half feet ( cokposite ) 17.1.37 100 w gls clear / milky lamp reputed make ( only supply ) 17.1.38 100 w gls clear / milky lamp reputed make ( only labour ) 17.1.39 100 w gls clear / milky lamp reputed make ( composite ) 17.1.40 200w clear / milky gls lamp ( only supply ) 17.1.41 200w clearmtilky gls lamp ( only labour ) 17.1.42 200w clearmtilky gls lamp ( composite ) 17.1.43 60 w gls clear / milky lamp reputed make ( only supply ) 17.1.44 60 w gls clear / milky lamp reputed make ( only labour ) 17.1.45 60 w gls clear / milky lamp reputed make ( composite ) 17.1.46 40 w clear / milky gls lamp ( only supply ) 17.1.47 40 w clear / miilky gls lamp ( only ) 17.1.48 40 w clear / milky gls lamp ( only supply ) 17.1.49 25 w clear / milky lamp reputed make ( only supply ) 17.1.50 25 w clear / milky lamp reputed make ( only labour ) 17.1.51 25 w clear / milky lamp reputed make ( composite ) 17.1.52 15 w red indication lamp reputed make / or other colour for any other specific application. ( supply ) 17.1.53 15 w red indication lamp reputed make / or other colour for any other specific application. ( labour ) 17.1.54 15 w red indication lamp reputed make / or other colour for any other specific application. ( composite ) 17.1.55 25 w incandescent lamp for exit light ( as per sample ) ( only supply ) 17.1.56 25 w incandescent lamp for exit light ( as per sample ) ( only labour ) 17.1.57 25 w incandescent lamp for exit light ( as per sample ) ( composite ) 17.1.58 8 w / 11w pin type cfl lamp ( only supply ) 17.1.59 8 w / 11w pin type cfl lamp ( only labour ) 17.1.60 8 w / 11w pin type cfl lamp ( composite ) 17.1.61 14 w pin type cfl lamp ( only supply ) 17.1.62 14 w pin type cfl lamp ( only labour ) 17.1.63 14 w pin type cfl lamp ( composite ) 17.1.64 23 / 25 w cfl tube ( only supply ) 17.1.65 23 / 25 w cfl tube ( only labour ) 17.1.66 23 / 25 w cfl tube ( composite ) 17.1.67 14 w plc tube ( only supply ) 17.1.68 14 w plc tube ( only labour ) 17.1.69 14 w plc tube ( composite ) 17.1.70 36 w pll tube light ( only supply ) 17.1.71 36 w pll tube light ( only labour ) 17.1.72 36 w pll tube light ( composite ) 17.1.73 electronic choke for 36 w pll fitting ( only supply ) 17.1.74 electronic choke for 36 w pll fitting ( only labour ) 17.1.75 electronic choke for 36 w pll fitting ( composite ) 17.1.76 40 w choke / ballast reputed make ( only supply ) 17.1.77 40 w choke / ballast reputed make ( only labour ) 17.1.78 40 w choke / ballast reputed make ( composite ) 17.1.79 electronic choke ( 40 w ) ( only supply ) 17.1.80 electronic choke ( 40 w ) ( only labour ) 17.1.81 electronic choke ( 40 w ) ( composite ) 17.1.82 20 w choke / ballast reputed make ( only supply ) 17.1.83 20 w choke / ballast reputed make ( only labour ) 17.1.84 20 w choke / ballast reputed make ( only composite ) 17.1.85 9 w choke / ballast reputed make ( only supply ) 17.1.86 9 w choke / ballast reputed make ( only labour ) 17.1.87 9 w choke / ballast reputed make ( composite ) 17.1.88 11 w choke / ballast reputed make ( only supply ) 17.1.89 11 w choke / ballast reputed make ( only labour ) 17.1.90 11 w choke / ballast reputed make ( composite ) 17.1.91 30 w choke / ballast for germicidal fixture gajjars make ( only supply ) 17.1.92 30 w choke / ballast for germicidal fixture gajjars make ( only labour ) 17.1.93 30 w choke / ballast for germicidal fixture gajjars make ( composite ) 17.1.94 fixing / replacing of side holders ( 1 no. ) ( only supply ) 17.1.95 fixing / replacing of side holders ( 1 no. ) ( only labour ) 17.1.96 fixing / replacing of side holders ( 1 no. ) ( composite ) 17.1.97 starter for fluorescent 36w tube light ( only supply ) 17.1.98 starter for fluorescent 36w tube light ( only labour ) 17.1.99 starter for fluorescent 36w tube light ( composite ) 17.1.100 replacing of starter holder for tube light ( only supply ) 17.1.101 replacing of starter holder for tube light ( only labour ) 17.1.102 replacing of starter holder for tube light ( composite ) 17.1.103 replacing of side holder for pl lamp fitting ( only supply ) 17.1.104 replacing of side holder for pl lamp fitting ( only labour ) 17.1.105 replacing of side holder for pl lamp fitting ( composite ) 17.1.106 replacing of halogen tube reputed make 500 w ( only supply ) 17.1.107 replacing of halogen tube reputed make 500 w ( only labour ) 17.1.108 replacing of halogen tube reputed make 500 w ( composite ) 17.1.109 replacing of halogen tube reputed make 1000 w ( only supply ) 17.1.110 replacing of halogen tube reputed make 1000 w ( only labour ) 17.1.111 replacing of halogen tube reputed make 1000 w ( composite ) 17.1.112 15 w ( pigmy lamp ) ( only supply ) 17.1.113 15 w ( pigmy lamp ) ( only labour ) 17.1.114 15 w ( pigmy lamp ) ( composite ) 17.1.115 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only supply ) 17.1.116 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( only labour ) 17.1.117 floor washer / wall washer light of 230volt , 20w , led 2400k , low light aluminium body , flush in wall ground type ( composite ) 17.1.118 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only supply ) 17.1.119 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( only labour ) 17.1.120 philips or equivalent 12 v, 50 w, halogen lamp for down lighter / spot light fittings ( composite ) 17.1.121 18 w reputed make choke suitable for 18 w plc tubes ( only supply ) 17.1.122 18 w reputed make choke suitable for 18 w plc tubes ( only labour ) 17.1.123 18 w reputed make choke suitable for 18 w plc tubes ( composite ) 17.1.124 decorative general type table / wall / reading lamp ( plc / cfl / incandescent lamp compatible etc ) ( only supply ) 17.1.125 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only supply ) 17.1.126 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( only labour ) 17.1.127 decorative type table / wall lamp ( plc / cfl / incandescent lamp compatible etc ) but for customized application. as directed by o i c, es ( composite ) 17.1.128 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only supply ) 17.1.129 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( only labour ) 17.1.130 fixing / replacement of 25w / 20w plc tube for existing makes lighting fixture ( composite ) 17.1.131 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only supply ) 17.1.132 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( only labour ) 17.1.133 fixing / replacement of 8w t5, 1 feet long fluorescent tube light ( composite ) 17.1.134 fixing / replacement of 18 / 20w electronic choke ( only supply ) 17.1.135 fixing / replacement of 18 / 20w electronic choke ( only labour ) 17.1.136 fixing / replacement of 18 / 20w electronic choke ( composite ) 17.1.137 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only supply ) 17.1.138 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( only labour ) 17.1.139 fixing / replacement of 28w t 5 energy efficient fluorescent tube ( composite ) 17.1.140 fixing / replacement of 30w fluroscent tube ( only supply ) 17.1.141 fixing / replacement of 30w fluroscent tube ( only labour ) 17.1.142 fixing / replacement of 30w fluroscent tube ( composite ) 17.1.143 fixing / replacement of 9 / 11w electronic choke ( only supply ) 17.1.144 fixing / replacement of 9 / 11w electronic choke ( only labour ) 17.1.145 fixing / replacement of 9 / 11w electronic choke ( composite ) 17.1.146 fixing / replacement of 100w comptlux lamp ( only supply ) 17.1.147 fixing / replacement of 100w comptlux lamp ( only labour ) 17.1.148 fixing / replacement of 100w comptlux lamp ( composite ) 17.1.149 30w tube light 3feet ( only supply ) 17.1.150 30w tube light 3feet ( only labour ) 17.1.151 30w tube light 3feet ( composite ) 17.2 led lamps pin type / thread type 17.2.1 fixing / replacement of 2 / 3w led lamp ( only supply ) 17.2.2 fixing / replacement of 2 / 3w led lamp ( only labour ) 17.2.3 fixing / replacement of 2 / 3w led lamp ( composite ) 17.2.4 fixing / replacement of 5 / 7 / 9w led lamp ( only supply ) 17.2.5 fixing / replacement of 5 / 7 / 9w led lamp ( only labour ) 17.2.6 fixing / replacement of 5 / 7 / 9w led lamp ( composite ) 17.2.7 fixing / replacement of 12w led lamp ( only supply ) 17.2.8 fixing / replacement of 12w led lamp ( only labour ) 17.2.9 fixing / replacement of 12w led lamp ( composite ) 17.2.10 fixing / replacement of 15w led lamp ( only supply ) 17.2.11 fixing / replacement of 15w led lamp ( only labour ) 17.2.12 fixing / replacement of 15w led lamp ( composite ) 17.2.13 fixing / replacement of 18w led lamp ( only supply ) 17.2.14 fixing / replacement of 18w led lamp ( only labour ) 17.2.15 fixing / replacement of 18w led lamp ( composite ) 17.2.16 fixing / replacement of 8w 2 long led tube ( only supply ) 17.2.17 fixing / replacement of 8w 2 long led tube ( only labour ) 17.2.18 fixing / replacement of 8w 2 long led tube ( composite ) 17.2.19 fixing / replacement of 18w led pll lamp ( only supply ) 17.2.20 fixing / replacement of 18w led pll lamp ( only labour ) 17.2.21 fixing / replacement of 18w led pll lamp ( composite ) 17.2.22 fixing / replacement of 30w led lamp ( only supply ) 17.2.23 fixing / replacement of 30w led lamp ( only labour ) 17.2.24 fixing / replacement of 30w led lamp ( composite ) 17.2.25 fixing / replacement of 35w led lamp ( only supply ) 17.2.26 fixing / replacement of 35w led lamp ( only labour ) 17.2.27 fixing / replacement of 35w led lamp ( composite ) 17.3 led driver 17.3.1 fixing / replacement of 3 / 5w led driver ( only supply ) 17.3.2 ffixing / replacement 3 / 5w led driver ( only labour ) 17.3.3 fixing / replacement of 3 / 5w led driver ( composite ) 17.3.4 fixing / replacement of 9w led driver ( only supply ) 17.3.5 ffixing / replacement 9w led driver ( only labour ) 17.3.6 fixing / replacement of 9w led driver ( composite ) 17.3.7 fixing / replacement of 12 / 15w led driver ( only supply ) 17.3.8 ffixing / replacement 12 / 15w led driver ( only labour ) 17.3.9 fixing / replacement of 12 / 15w led driver ( composite ) 17.3.10 fixing / replacement of 18w led driver ( only supply ) 17.3.11 ffixing / replacement 18w led driver ( only labour ) 17.3.12 fixing / replacement of 18w led driver ( composite ) 17.3.13 fixing / replacement of 24w led driver ( only supply ) 17.3.14 ffixing / replacement 24w led driver ( only labour ) 17.3.15 fixing / replacement of 24w led driver ( composite ) 17.3.16 fixing / replacement of 30w led driver ( only supply ) 17.3.17 ffixing / replacement 30w led driver ( only labour ) 17.3.18 fixing / replacement of 30w led driver ( composite ) 17.3.19 fixing / replacement of 36w led driver ( only supply ) 17.3.20 ffixing / replacement 36w led driver ( only labour ) 17.3.21 fixing / replacement of 36w led driver ( composite ) 18.1 gyesers / heaters supply, installation, testing & commissining of various types of water gyesers, heaters, heating coils, hot plates, strip heaters or any similar application heating equipment as per the required specifications as per instructions & as directed by e i c, es. in case of replacement / repairs, old items are to be handed over to e i c, es along with gatepass / challans etc. 18.1.1 25 litre capacity , hospital use water heater ( only supply ) 18.1.2 25 litre capacity , hospital use water heater ( only labour ) 18.1.3 25 litre capacity , hospital use water heater ( composite ) 18.1.4 reputed make 6 litre capacity , hospital use water heater ( only supply ) 18.1.5 reputed make 6 litre capacity , hospital use water heater ( only labour ) 18.1.6 reputed make 6 litre capacity , hospital use water heater ( composite ) 18.1.7 reputed make 1 litre capacity water geyser ( only supply ) 18.1.8 reputed make 1 litre capacity water geyser ( only labour ) 18.1.9 reputed make 1 litre capacity water geyser ( composite ) 18.1.10 reputed make 2 litre capacity water geyser ( only supply ) 18.1.11 reputed make 2 litre capacity water geyser ( only labour ) 18.1.12 reputed make 2 litre capacity water geyser ( composite ) 18.1.13 reputed make 3 litre capacity water geyser ( only supply ) 18.1.14 reputed make 3 litre capacity water geyser ( only labour ) 18.1.15 reputed make 3 litre capacity water geyser ( composite ) 18.2 thermostats and heating coils. 18.2.1 thermostat of good quality for all types of gysers ( only supply ) 18.2.2 thermostat of good quality for all types of gysers ( only labour ) 18.2.3 thermostat of good quality for all types of gysers ( composite ) 18.2.4 thermostats0 300 oc for oven ( only supply ) 18.2.5 thermostats0 300 oc for oven ( only labour ) 18.2.6 thermostats0 300 oc for oven ( composite ) 18.2.7 supply / replacement of coil for hot plate ( only supply ) 18.2.8 supply / replacement of coil for hot plate ( only supply ) 18.2.9 supply / replacement of coil for hot plate ( only supply ) 18.2.10 supply / replacement of coil for iron ( only supply ) 18.2.11 supply / replacement of coil for iron ( only labour ) 18.2.12 supply / replacement of coil for iron ( composite ) 18.2.13 fixing / replacement of coil / tube type heaters for geysers1000 w ( only supply ) 18.2.14 fixing / replacement of coil / tube type heaters for geysers1000 w ( only labour ) 18.2.15 fixing / replacement of coil / tube type heaters for geysers1000 w ( composite ) 18.2.16 fixing / replacement of coil / tube type heaters for geysers1500 w ( only supply ) 18.2.17 fixing / replacement of coil / tube type heaters for geysers1500 w ( only labour ) 18.2.18 fixing / replacement of coil / tube type heaters for geysers1500 w ( composite ) 18.2.19 fixing / replacement of coil / tube type heaters for geysers2000 w ( only supply ) 18.2.20 fixing / replacement of coil / tube type heaters for geysers2000 w ( only labour ) 18.2.21 fixing / replacement of coil / tube type heaters for geysers2000 w ( composite ) 18.2.22 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only supply ) 18.2.23 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( only labour ) 18.2.24 fixing / replacement of coil / tube type heaters for geysers3000 w ( general ) ( composite ) 18.2.25 3000 w ( idli / chapati maker etc ) ( only supply ) 18.2.26 3000 w ( idli / chapati maker etc ) ( only labour ) 18.2.27 3000 w ( idli / chapati maker etc ) ( composite ) 18.2.28 500 w coil heater ( only supply ) 18.2.29 500 w coil heater ( only labour ) 18.2.30 500 w coil heater ( composite ) 18.2.31 replacement of kettle heaters ( only supply ) 18.2.32 replacement of kettle heaters ( only labour ) 18.2.33 replacement of kettle heaters ( composite ) 18.2.34 replacement of over load relay for gysers / hot plates and other similar equipments. ( only supply ) 18.2.35 replacement of over load relay for gysers / hot plates and other similar equipments. ( only labour ) 18.2.36 replacement of over load relay for gysers / hot plates and other similar equipments. ( composite ) 18.2.37 replacement of sealer coil ( only supply ) 18.2.38 replacement of sealer coil ( only labour ) 18.2.39 replacement of sealer coil ( composite ) 18.3 strip heaters. 18.3.1 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only supply ) 18.3.2 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( only labour ) 18.3.3 finned type strip heater for ahu, 5 kw ( for approx size 1.5 mtrs / as per sample ) ( composite ) 18.3.4 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only supply ) 18.3.5 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( only labour ) 18.3.6 finned type strip heater for ahu, 5 kw ( for approx size 0.75 mtrs / as per sample ) ( composite ) 18.3.7 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.8 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.9 finned type strip heater for ahu, 6 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.10 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.11 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.12 finned type strip heater for ahu, 3 kw ( as per sample ) or as directed by o i c, es ( composite ) 18.3.13 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only supply ) 18.3.14 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( only labour ) 18.3.15 finned type strip heater for ahu, 2 kw ( as per sample ) or as directed by o i c, es ( composite ) 19.1.a mv cable work supply. installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round / flat wire armoured copper / al conductor power cables isi mark reputed make fixed on wall / column / ceiling or in shaft / existing trench on 6 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.1.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.1.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.1.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.1.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.1.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.1.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.1.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.1.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.1.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.1.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.1.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.1.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.1.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.1.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.1.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.1.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.1.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.1.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.1.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.1.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.1.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.2 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.2.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.2.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.2.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.2.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.2.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.2.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.2.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.2.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.2.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.2.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.2.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.2.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.2.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.2.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.2.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.2.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.2.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.2.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.2.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.2.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.2.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.3 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.3.1 2 x 4 sq. mm copper conductor cable ( only supply ) 19.3.2 2 x 4 sq. mm copper conductor cable ( only labour ) 19.3.3 2 x 4 sq. mm copper conductor cable ( composite ) 19.3.4 2 x 6 sq. mm copper conductor cable ( only supply ) 19.3.5 2 x 6 sq. mm copper conductor cable ( only labour ) 19.3.6 2 x 6 sq. mm copper conductor cable ( composite ) 19.3.7 3 x 1.5 sq. mm copper conductor cable ( only supply ) 19.3.8 3 x 1.5 sq. mm copper conductor cable ( only labour ) 19.3.9 3 x 1.5 sq. mm copper conductor cable ( composite ) 19.3.10 3 x 2.5 sq. mm copper conductor cable ( only supply ) 19.3.11 3 x 2.5 sq. mm copper conductor cable ( only labour ) 19.3.12 3 x 2.5 sq. mm copper conductor cable ( composite ) 19.3.13 3 x 4 sq. mm copper conductor cable ( only supply ) 19.3.14 3 x 4 sq. mm copper conductor cable ( only labour ) 19.3.15 3 x 4 sq. mm copper conductor cable ( composite ) 19.3.16 3 x 6 sq. mm copper conductor cable ( only supply ) 19.3.17 3 x 6 sq. mm copper conductor cable ( only labour ) 19.3.18 3 x 6 sq. mm copper conductor cable ( composite ) 19.3.19 3 x 10 sq. mm copper conductor cable ( only supply ) 19.3.20 3 x 10 sq. mm copper conductor cable ( only labour ) 19.3.21 3 x 10 sq. mm copper conductor cable ( composite ) 19.4 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured copper / aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench on 5 mm thick spacers / angle support fixed with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg. in charge. 19.4.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.4.2. 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.4.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.4.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.4.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.4.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.4.7 4 x 4 sq. mm copper conductor ( only supply ) 19.4.8 4 x 4 sq. mm copper conductor ( only labour ) 19.4.9 4 x 4 sq. mm copper conductor ( composite ) 19.4.10 4 x 6 sq. mm copper conductor ( only supply ) 19.4.11 4 x 6 sq. mm copper conductor ( only labour ) 19.4.12 4 x 6 sq. mm copper conductor ( composite ) 19.4.13 4 x 10 sq. mm copper conductor ( only supply ) 19.4.14 4 x 10 sq. mm copper conductor ( only labour ) 19.4.15 4 x 10 sq. mm copper conductor ( composite ) 19.4.16 4 x 16 sq. mm copper conductor ( only supply ) 19.4.17 4 x 16 sq. mm copper conductor ( only labour ) 19.4.18 4 x 16 sq. mm copper conductor ( composite ) 19.4.19 4 x 25 sq. mm copper conductor ( only supply ) 19.4.20 4 x 25 sq. mm copper conductor ( only labour ) 19.4.21 4 x 25 sq. mm copper conductor ( composite ) 19.4.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.4.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.4.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.4.25 4 x 10 sq. mm al conductor ( only supply ) 19.4.26 4 x 10 sq. mm al conductor ( only labour ) 19.4.27 4 x 10 sq. mm al conductor ( composite ) 19.4.28 4 x 16 sq. mm al conductor ( only supply ) 19.4.29 4 x 16 sq. mm al conductor ( only labour ) 19.4.30 4 x 16 sq. mm al conductor ( composite ) 19.4.31 4 x 25 sq. mm al conductor ( only supply ) 19.4.32 4 x 25 sq. mm al conductor ( only labour ) 19.4.33 4 x 25 sq. mm al conductor ( composite ) 19.4.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.4.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.4.36 3.5 x 25 sq. mm al conducto ( composite ) 19.4.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.4.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.4.39 3.5 x 35 sq. mm al conductor ( composite ) 19.4.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.4.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.4.42 3.5 x 50 sq. mm al conducto ( composite ) 19.4.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.4.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.4.45 3.5 x 70 sq. mm al conductor ( composite ) 19.4.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.4.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.4.48 3.5 x 95 sq. mm al conductor ( composite ) 19.5 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.5.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.5.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.5.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.5.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.5.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.5.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.5.7 4 x 4 sq. mm copper conductor ( only supply ) 19.5.8 4 x 4 sq. mm copper conductor ( only labour ) 19.5.9 4 x 4 sq. mm copper conductor ( composite ) 19.5.10 4 x 6 sq. mm copper conductor ( only supply ) 19.5.11 4 x 6 sq. mm copper conductor ( only labour ) 19.5.12 4 x 6 sq. mm copper conductor ( composite ) 19.5.13 4 x 10 sq. mm copper conductor ( only supply ) 19.5.14 4 x 10 sq. mm copper conductor ( only labour ) 19.5.15 4 x 10 sq. mm copper conductor ( composite ) 19.5.16 4 x 16 sq. mm copper conductor ( only supply ) 19.5.17 4 x 16 sq. mm copper conductor ( only labour ) 19.5.18 4 x 16 sq. mm copper conductor ( composite ) 19.5.19 4 x 25 sq. mm copper conductor ( only supply ) 19.5.20 4 x 25 sq. mm copper conductor ( only labour ) 19.5.21 4 x 25 sq. mm copper conductor ( composite ) 19.5.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.5.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.5.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.5.25 4 x 10 sq. mm al conductor ( only supply ) 19.5.26 4 x 10 sq. mm al conductor ( only labour ) 19.5.27 4 x 10 sq. mm al conductor ( composite ) 19.5.28 4 x 16 sq. mm al conductor ( only supply ) 19.5.29 4 x 16 sq. mm al conductor ( only labour ) 19.5.30 4 x 16 sq. mm al conductor ( composite ) 19.5.31 4 x 25 sq. mm al conductor ( only supply ) 19.5.32 4 x 25 sq. mm al conductor ( only labour ) 19.5.33 4 x 25 sq. mm al conductor ( composite ) 19.5.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.5.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.5.36 3.5 x 25 sq. mm al conducto ( composite ) 19.5.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.5.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.5.39 3.5 x 35 sq. mm al conductor ( composite ) 19.5.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.5.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.5.42 3.5 x 50 sq. mm al conducto ( composite ) 19.5.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.5.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.5.45 3.5 x 70 sq. mm al conductor ( composite ) 19.5.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.5.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.5.48 3.5 x 95 sq. mm al conductor ( composite ) 19.6 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed copper / aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.6.1 4 x 1.5 sq. mm. copper conductor ( only supply ) 19.6.2 4 x 1.5 sq. mm. copper conductor ( only labour ) 19.6.3 4 x 1.5 sq. mm. copper conductor ( composite ) 19.6.4 4 x 2.5 sq. mm .copper cable ( only supply ) 19.6.5 4 x 2.5 sq. mm .copper cable ( only labour ) 19.6.6 4 x 2.5 sq. mm .copper cable ( composite ) 19.6.7 4 x 4 sq. mm copper conductor ( only supply ) 19.6.8 4 x 4 sq. mm copper conductor ( only labour ) 19.6.9 4 x 4 sq. mm copper conductor ( composite ) 19.6.10 4 x 6 sq. mm copper conductor ( only supply ) 19.6.11 4 x 6 sq. mm copper conductor ( only labour ) 19.6.12 4 x 6 sq. mm copper conductor ( composite ) 19.6.13 4 x 10 sq. mm copper conductor ( only supply ) 19.6.14 4 x 10 sq. mm copper conductor ( only labour ) 19.6.15 4 x 10 sq. mm copper conductor ( composite ) 19.6.16 4 x 16 sq. mm copper conductor ( only supply ) 19.6.17 4 x 16 sq. mm copper conductor ( only labour ) 19.6.18 4 x 16 sq. mm copper conductor ( composite ) 19.6.19 4 x 25 sq. mm copper conductor ( only supply ) 19.6.20 4 x 25 sq. mm copper conductor ( only labour ) 19.6.21 4 x 25 sq. mm copper conductor ( composite ) 19.6.22 3.5 x 25 sq.mm copper conductor ( only supply ) 19.6.23 3.5 x 25 sq.mm copper conductor ( only labour ) 19.6.24 3.5 x 25 sq.mm copper conductor ( composite ) 19.6.25 4 x 10 sq. mm al conductor ( only supply ) 19.6.26 4 x 10 sq. mm al conductor ( only labour ) 19.6.27 4 x 10 sq. mm al conductor ( composite ) 19.6.28 4 x 16 sq. mm al conductor ( only supply ) 19.6.29 4 x 16 sq. mm al conductor ( only labour ) 19.6.30 4 x 16 sq. mm al conductor ( composite ) 19.6.31 4 x 25 sq. mm al conductor ( only supply ) 19.6.32 4 x 25 sq. mm al conductor ( only labour ) 19.6.33 4 x 25 sq. mm al conductor ( composite ) 19.6.34 3.5 x 25 sq. mm al conducto ( only supply ) 19.6.35 3.5 x 25 sq. mm al conducto ( only labour ) 19.6.36 3.5 x 25 sq. mm al conducto ( composite ) 19.6.37 3.5 x 35 sq. mm al conductor ( only supply ) 19.6.38 3.5 x 35 sq. mm al conductor ( only labour ) 19.6.39 3.5 x 35 sq. mm al conductor ( composite ) 19.6.40 3.5 x 50 sq. mm al conducto ( only supply ) 19.6.41 3.5 x 50 sq. mm al conducto ( only labour ) 19.6.42 3.5 x 50 sq. mm al conducto ( composite ) 19.6.43 3.5 x 70 sq. mm al conductor ( only supply ) 19.6.44 3.5 x 70 sq. mm al conductor ( only lanbour ) 19.6.45 3.5 x 70 sq. mm al conductor ( composite ) 19.6.46 3.5 x 95 sq. mm al conductor ( only supply ) 19.6.47 3.5 x 95 sq. mm al conductor ( only labour ) 19.6.48 3.5 x 95 sq. mm al conductor ( composite ) 19.7 supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded / round wire armoured aluminium conductor power cables isi mark fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous 8 swg copper bare wire for earthing & end termination. 19.7.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.7.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.7.3 3.5 x 120 sq. mm al conductor ( composite ) 19.7.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.7.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.7.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.7.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.7.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.7.9 3.5 x 185 sq. mm al conductor ( composite ) 19.7.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.7.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.7.12 3.5 x 240 sq. mm al conductor ( composite ) 19.7.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.7.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.7.15 3.5 x 300 sq. mm al conductor ( composite ) 19.7.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.7.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.7.18 3.5 x 400 sq. mm al conductor ( composite ) 19.8 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable below earth 900 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.8.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.8.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.8.3 3.5 x 120 sq. mm al conductor ( composite ) 19.8.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.8.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.8.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.8.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.8.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.8.9 3.5 x 185 sq. mm al conductor ( composite ) 19.8.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.8.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.8.12 3.5 x 240 sq. mm al conductor ( composite ) 19.8.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.8.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.8.15 3.5 x 300 sq. mm al conductor ( composite ) 19.8.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.8.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.8.18 3.5 x 400 sq. mm al conductor ( composite ) 19.9 supply, laying, testing & commissioning of 1.1 kv ac grade pvc insulated isi mark armored, bright annealed aluminium conductor cable in ground at 900 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.9.1 3.5 x 120 sq. mm al conductor ( only supply ) 19.9.2 3.5 x 120 sq. mm al conductor ( only labour ) 19.9.3 3.5 x 120 sq. mm al conductor ( composite ) 19.9.4 3.5 x 150 sq. mm al conductor ( only supply ) 19.9.5 3.5 x 150 sq. mm al conductor ( only labour ) 19.9.6 3.5 x 150 sq. mm al conductor ( compoiste ) 19.9.7 3.5 x 185 sq. mm al conductor ( only supply ) 19.9.8 3.5 x 185 sq. mm al conductor ( only labour ) 19.9.9 3.5 x 185 sq. mm al conductor ( composite ) 19.9.10 3.5 x 240 sq. mm al conductor ( only supply ) 19.9.11 3.5 x 240 sq. mm al conductor ( only labour ) 19.9.12 3.5 x 240 sq. mm al conductor ( composite ) 19.9.13 3.5 x 300 sq. mm al conductor ( only supply ) 19.9.14 3.5 x 300 sq. mm al conductor ( only labour ) 19.9.15 3.5 x 300 sq. mm al conductor ( composite ) 19.9.16 3.5 x 400 sq. mm al conductor ( only supply ) 19.9.17 3.5 x 400 sq. mm al conductor ( only labour ) 19.9.18 3.5 x 400 sq. mm al conductor ( composite ) 19.10.a supply, installation, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark make fixed on wall / coloum / ceiling or in shaft / existing trench with screws / coach screws / anchor fasteners, all other fixing accessories etc. as per instruction of engg in charge. & following size along with double run continuous copper strip / wire earthing as required & as directed by o i c, es. 19.10.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.10.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.10.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.10.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.10.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.10.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.10.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.10.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.10.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.10.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.10.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.10.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.11 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11 / 33 kv grade cable, isi mark pvc insulated isi mark armored, bright annealed copper conductor cable below earth 1200 mm. cable in the ground shall be covered on top & sides with baked bricks conforming to is 107 including dewatering, sand bedding, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr as per instruction of e i c. 19.11.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.11.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.11.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.11.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.11.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.11.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.11.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.11.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.11.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.11.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.11.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.11.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 19.12 supply, laying, testing & commissioning of compact circular aluminum conductor, conductor screened with extruded semi conducting compound xlpe insulated, insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for one sec. ) , cores laid up, inner sheath of pvc tape, galvanized steel flat strip armoured & overall pvs sheathed cable with latest amendments, 11kv grade cable, isi mark , laying in ground at 1200 mm through suitable size of dwc hdpe pipes, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge, back filling & re instatement, consolidation & removal of excess earth with in a radius of 500 mtr. as per instruction of e i c. 19.12.1 3 x 240 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.2 3 x 240 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.3 3 x 240 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.4 3 x 300 sq. mm. al conductor ( 11 kv ) ( only supply ) 19.12.5 3 x 300 sq. mm. al conductor ( 11 kv ) ( only labour ) 19.12.6 3 x 300 sq. mm. al conductor ( 11 kv ) ( composite ) 19.12.7 3 x 400 sq. mm al conductor ( 11 kv ) ( only supply ) 19.12.8 3 x 400 sq. mm al conductor ( 11 kv ) ( only labour ) 19.12.9 3 x 400 sq. mm al conductor ( 11 kv ) ( composite ) 19.12.10 3 x 240 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.11 3 x 240 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.12 3 x 240 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.13 3 x 300 sq. mm. al conductor ( 33 kv ) ( only supply ) 19.12.14 3 x 300 sq. mm. al conductor ( 33 kv ) ( only labour ) 19.12.15 3 x 300 sq. mm. al conductor ( 33 kv ) ( composite ) 19.12.16 3 x 400 sq. mm al conductor ( 33 kv ) ( only supply ) 19.12.17 3 x 400 sq. mm al conductor ( 33 kv ) ( only labour ) 19.12.18 3 x 400 sq. mm al conductor ( 33 kv ) ( composite ) 20.1 gi pipes / foot valvessupply, installation gi pipes class b type with all fixing arrangement such as couplings, bends etc on any kind of surface or below ground as per the instruction of e i c. 20.1.1 gi pipe 25 mm ( only supply ) 20.1.2 gi pipe 25 mm ( only labour ) 20.1.3 gi pipe 25 mm ( composite ) 20.1.4 gi pipe 32 mm ( only supply ) 20.1.5 gi pipe 32 mm ( only labour ) 20.1.6 gi pipe 32 mm ( composite ) 20.1.7 gi pipe 38 mm ( only supply ) 20.1.8 gi pipe 38 mm ( only labour ) 20.1.9 gi pipe 38 mm ( composite ) 20.1.10 gi pipe 50 mm ( only supply ) 20.1.11 gi pipe 50 mm ( only labour ) 20.1.12 gi pipe 50 mm ( composite ) 20.2 supply / replacement of foot valve of various sizes with all necessary arrangement for making it properly function, all as per the instructions and as per directions of e i c, es 20.2.1 threefourth inch ( only supply ) 20.2.2 threefourth inch ( only labour ) 20.2.3 threefourth inch ( composite ) 20.2.4 1inch ( only supply ) 20.2.5 1inch ( only labour ) 20.2.6 1inch ( composite ) 20.2.7 2inch ( only supply ) 20.2.8 2inch ( only labour ) 20.2.9 2inch ( composite ) 20.2.10 3inch ( only supply ) 20.2.11 3inch ( only labour ) 20.2.12 3inch ( composite ) 20.3 exavation / hume pipes / dwc pipes 20.3.1 supply, installation of oval / circular shape gi casted cable marker complete with 38 m dia gi support 1: 3: 6 pcc base, concreting / gi nut bolts, engraved as ht / mv / lt / tel.cables etc. as per instruction of eic. all as directed by o i c with prior approval. ( composite ) 20.3.2 exavation of all kind of soil as per required 900 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, reinstatement, after work completion, if necessary disposal of excess earth within the radius of 500 mtrs etc, stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.3 exavation of hard rock as per reuired 900 / 1200 mm below ground level including blasting & chiseling, using compressor, dewatering, back filling, if necessary disposal of excess earth within the radius of 500 mtrs etc. stacking of rocks at selected places as per instruction of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 150 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 20.3.4 supply & laying of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only supply ) 20.3.5 supply & istallation of rcc hume pipe400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( only labour ) 20.3.6 supply & istallation of rcc hume pipe 400 mm dia along with collars including exavation in all types of soils / rock / asphalts road / comcrete road / jointing of pipes with cement, consolidating & making good surface as per the existing all as per the instructions of eic. ( composite ) 21 supply, laying, testing & commissioning of rg 11 television cable through casing capping / pvc conduits / gi ms pipes on any kind of surface / below ground through dwc pipe through out the campus as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es. 21.1 rg 11 cable ( only supply ) 21.2 rg 11 cable supply and laying pvc casing capping / conduit pipe ( composite ) 21.3 rg 11 cable laying through dwc hdpe pipe pipe ( composite ) 21.10.a supply of rg 59 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.11 laying of rg 59 television cable through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.12 supply, laying, testing & commissioning of rg 59 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 21.13 supply of rg 6 television cable as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only supply ) 21.14 laying of rg 6 television cable through provided casing capping / pvc conduits / gi ms pipes any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( only labour ) 21.15 supply, laying, testing & commissioning of rg 6 television cable of through provided casing capping / pvc conduits / gi ms pipes on any kind of surface as per requirment with all accessories and fixing arrangement all as per instructions & as directed by e i c, es ( composite ) 22 corrogated water pipe 22.1 supply / replacement of corrogated water pipe with prior approval will all accessories and fixing arrangement, all as per instructions and as directed by e i c, es. 22.1.1 threefourth inch ( only supply ) 22.1.2 threefourth inch ( only labour ) 22.1.3 threefourth inch ( composite ) 22.1.4 1inch ( only supply ) 22.1.5 1inch ( only labour ) 22.1.6 1inch ( composite ) 22.1.7 2inch ( only supply ) 22.1.8 2inch ( only labour ) 22.1.9 2inch ( composite ) 22.1.10 3inch ( only supply ) 22.1.11 3inch ( only labour ) 22.1.12 3inch ( composite ) 23.1 telephone cable / joint kits / tag blockssupply, installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed cable fixed on slab / wall / coloum / existing trench etc. on 6 mm thick gi spacer / ms flat support with wooden screws with 18 swg gi saddle all fixing accessories & jointing of the both the ends of cable s with all jointing materials like cable glands, cable end box if required, ferrule lugs, ferrule numbers, wire dressing clamps / buttons etc. complete all as per instruction of e i c. 23.1.1 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only supply ) 23.1.2 as per item no 23.1 but for 0.5 mm dia 10 pair. ( only labour ) 23.1.3 as per item no 23.1 but for 0.5 mm dia 10 pair. ( composite ) 23.1.4 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only supply ) 23.1.5 as per item no 23.1 but for 0.5 mm dia 20 pair. ( only labour ) 23.1.6 as per item no 23.1 but for 0.5 mm dia 20 pair. ( composite ) 23.1.7 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only supply ) 23.1.8 as per item no 23.1 but for 0.5 mm dia 50 pair. ( only labour ) 23.1.9 as per item no 23.1 but for 0.5 mm dia 50 pair. ( composite ) 23.1.10 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only supply ) 23.1.11 as per item no 23.1 but for 0.5 mm dia 100 pair. ( only labour ) 23.1.12 as per item no 23.1 but for 0.5 mm dia 100 pair. ( composite ) 23.1.13 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only supply ) 23.1.14 as per item no 23.1 but for 0.5 mm dia 200 pair. ( only labour ) 23.1.15 as per item no 23.1 but for 0.5 mm dia 200 pair. ( composite ) 23.2 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of soil / sand bedding laying of backed bricks as per is on side & top, back filling dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.2.1 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only supply ) 23.2.2 as per item no 23.2 but for 0.5 mm dia 10 pair. ( only labour ) 23.2.3 as per item no 23.2 but for 0.5 mm dia 10 pair. ( composite ) 23.2.4 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only supply ) 23.2.5 as per item no 23.2 but for 0.5 mm dia 20 pair. ( only labour ) 23.2.6 as per item no 23.2 but for 0.5 mm dia 20 pair. ( composite ) 23.2.7 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only supply ) 23.2.8 as per item no 23.2 but for 0.5 mm dia 50 pair. ( only labour ) 23.2.9 as per item no 23.2 but for 0.5 mm dia 50 pair. ( composite ) 23.2.10 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only supply ) 23.2.11 as per item no 23.2 but for 0.5 mm dia 100 pair. ( only labour ) 23.2.12 as per item no 23.2 but for 0.5 mm dia 100 pair. ( composite ) 23.2.13 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only supply ) 23.2.14 as per item no 23.2 but for 0.5 mm dia 200 pair. ( only labour ) 23.2.15 as per item no 23.2 but for 0.5 mm dia 200 pair. ( composite ) 23.3 supply installation, testing & commissioning of telephone cables with tinned grade annealed copper conductor pe insulated cores twisted jelly filled gi wire / strip armored pvc sheathed in ground at the depth of 700 mm below ground level including excavation of all type of laying through suitable dwc hdpe pipe, along with cable pulling chamber with heavy duty openable cover at the both end & if required in between as directed by in charge dewatering shoring, consolidating, disposal of excess earth within a radius of 500 meters, total reinstatement after work completion etc. complete as per the instruction of e i c. 23.3.1 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only supply ) 23.3.2 as per item no 23.3 but for 0.5 mm dia 10 pair. ( only labour ) 23.3.3 as per item no 23.3 but for 0.5 mm dia 10 pair. ( composite ) 23.3.4 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only supply ) 23.3.5 as per item no 23.3 but for 0.5 mm dia 20 pair. ( only labour ) 23.3.6 as per item no 23.3 but for 0.5 mm dia 20 pair. ( composite ) 23.3.7 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only supply ) 23.3.8 as per item no 23.3 but for 0.5 mm dia 50 pair. ( only labour ) 23.3.9 as per item no 23.3 but for 0.5 mm dia 50 pair. ( composite ) 23.3.10 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only supply ) 23.3.11 as per item no 23.3 but for 0.5 mm dia 100 pair. ( only labour ) 23.3.12 as per item no 23.3 but for 0.5 mm dia 100 pair. ( composite ) 23.3.13 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only supply ) 23.3.14 as per item no 23.3 but for 0.5 mm dia 200 pair. ( only labour ) 23.3.15 as per item no 23.3 but for 0.5 mm dia 200 pair. ( composite ) 23.4 supply, installation, testing & commissioning of straight through telephone jointing kits preferably of raychem make or alternately m seal of mahindra make for jelly filled armoured telephone cable including dressing, cleaning of the jelly, supply of all jointing materials, etc. complete as required and as per relevant specifications and as directed by e i c. 23.4.1 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only supply ) 23.4.2 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( only labour ) 23.4.3 as per item no 23.4 but for 10 pairs jelly filled armoured cable ( composite ) 23.4.4 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only supply ) 23.4.5 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( only labour ) 23.4.6 as per item no 23.4 but for 20 pairs jelly filled armoured cable ( composite ) 23.4.7 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only supply ) 23.4.8 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( only labour ) 23.4.9 as per item no 23.4 but for 50 pairs jelly filled armoured cable ( composite ) 23.4.10 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only supply ) 23.4.11 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( only labour ) 23.4.12 as per item no 23.4 but for 100 pairs jelly filled armoured cable ( composite ) 23.4.13 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only supply ) 23.4.14 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( only labour ) 23.4.15 as per item no 23.4 but for 200 pairs jelly filled armoured cable ( composite ) 23.5 supply, installation, testing & commissioning of crone connector telephone tag block box, fabricated out of 14 swg ms crca sheet mounted on ms frame of size 40 x 40 x 5 mm & grouted on the wall / fixed on the coloum free standing type with anchor fastener with front openable hinged doors cam type locking arrangements, neoprene gasket for joints painting with seven tank metal treatment process & with two coats of red oxide primer & two coats of approved shade enamel paint, norm plate etc. as per the instruction of eic. 23.5.1 2 x 10 ways telephone tag block. ( only supply ) 23.5.2 2 x 10 ways telephone tag block. ( only labour ) 23.5.3 2 x 10 ways telephone tag block. ( composite ) 23.5.4 2 x 20 ways telephone tag block. ( only supply ) 23.5.5 2 x 20 ways telephone tag block. ( only labour ) 23.5.6 2 x 20 ways telephone tag block. ( composite ) 23.5.7 2 x 50 ways telephone tag block. ( only supply ) 23.5.8 2 x 50 ways telephone tag block. ( only labour ) 23.5.9 2 x 50 ways telephone tag block. ( composite ) 23.5.10 2 x 60 ways telephone tag block. ( only supply ) 23.5.11 2 x 60 ways telephone tag block. ( only labour ) 23.5.12 2 x 60 ways telephone tag block. ( composite ) 23.5.13 2 x 100 ways telephone tag block. ( only supply ) 23.5.14 2 x 100 ways telephone tag block. ( only labour ) 23.5.15 2 x 100 ways telephone tag block. ( composite ) 23.5.16 2 x 200 ways telephone tag block. ( only supply ) 23.5.17 2 x 200 ways telephone tag block. ( only labour ) 23.5.18 2 x 200 ways telephone tag block. ( composite ) 23.5.19 2 x 240 ways telephone tag block. ( only supply ) 23.5.20 2 x 240 ways telephone tag block. ( only labour ) 23.5.21 2 x 240 ways telephone tag block. ( composite ) 23.5.22 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only supply ) 23.5.23 supply & fixing of 10 way crone connectors of good quality with prior approval. ( only labour ) 23.5.24 supply & fixing of 10 way crone connectors of good quality with prior approval. ( composite ) 24.1 cable glands and lugssupplying & erecting heavy duty flange type brass cable glands for end jointing of various sizes for pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected, with gland double earthing, work completed in all respect all as per instructions and as directed by e i c, es 24.1.1 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only supply ) 24.1.2 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( only labour ) 24.1.3 supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq. mm / 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable ends & leads connected ( composite ) 24.1.4 as per item no 24.1 but for but 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm as per item no 24.1 but for ( only supply ) 24.1.5 as per item no 24.1 but for 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( only labour ) 24.1.6 same as abovebut 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm same as above ( composite ) 24.1.7 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only supply ) 24.1.8 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( only labour ) 24.1.9 as per item no 24.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame as above ( composite ) 24.1.10 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only supply ) 24.1.11 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( only labour ) 24.1.12 as per item no 24.1 but for 3.5x35sq.mm / 3x50sq.mm same as above ( composite ) 24.1.13 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only supply ) 24.1.14 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( only labour ) 24.1.15 as per item no 24.1 but for 3.5 x 50 sq.mm same as above ( composite ) 24.1.16 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only supply ) 24.1.17 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( only labour ) 24.1.18 as per item no 24.1 but for 3.5 x 70 sq.mm same as above ( composite ) 24.1.19 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only supply ) 24.1.20 as per item no 24.1 but for 3.5 x 95 sq.mm same as above ( only labour ) 24.1.21 as per item no 24.1 but for 3.5 x 95 sq.mmsame as above ( composite ) 24.1.22 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( only supply ) 24.1.23 as per item no 24.1 but for 3.5 x 120 sq.mmsame as above ( only labour ) 24.1.24 as per item no 24.1 but for 3.5 x 120 sq.mm same as above ( composite ) 24.1.25 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only supply ) 24.1.26 as per item no 24.1 but for 3.5 x 150 sq.mm same as above ( only labour ) 24.1.27 as per item no 24.1 but for 3.5 x 150 sq.mmsame as above ( composite ) 24.1.28 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only supply ) 24.1.29 as per item no 24.1 but for 3.5 x 185 sq.mmsame as above ( only labour ) 24.1.30 as per item no 24.1 but for 3.5 x 185 sq.mm same as above ( compsite ) 24.1.31 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only supply ) 24.1.32 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( only labour ) 24.1.33 as per item no 24.1 but for 3.5 x 240 sq.mm same as above ( composite ) 24.1.34 as per item no 24.1 but for 3.5 x 300 sq.mmsame as above ( only supply ) 24.1.35 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( only labour ) 24.1.36 as per item no 24.1 but for 3.5 x 300 sq.mm same as above ( composite ) 24.1.37 as per item no 24.1 but for 3.5 x 400 sq.mmsame as above ( only supply ) 24.1.38 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( only labour ) 24.1.39 as per item no 24.1 but for 3.5 x 400 sq.mm same as above ( composite ) 24.2 lugs supplying & erecting crimping type copper lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.2.1 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only supply ) 24.2.2 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( only labour ) 24.2.3 supplying & erecting crimping type copper lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners. all as directed by o i c, es ( composite ) 24.2.4 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only supply ) 24.2.5 as per item no 24.2 but for 25 sq. mmas per item no 24.2 but for ( only labour ) 24.2.6 as per item no 24.2 but for 25 sq. mm as per item no 24.2 but for ( composite ) 24.2.7 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only supply ) 24.2.8 as per item no 24.2 but for 35 sq. mm as per item no 24.2 but for ( only labour ) 24.2.9 as per item no 24.2 but for 35 sq. mmas per item no 24.2 but for ( composite ) 24.2.10 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only supply ) 24.2.11 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( only labour ) 24.2.12 as per item no 24.2 but for 50 sq. mm as per item no 24.2 but for ( composite ) 24.2.13 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( only supply ) 24.2.14 as per item no 24.2 but for 70 sq. mmas per item no 24.2 but for ( only labour ) 24.2.15 as per item no 24.2 but for 70 sq. mm as per item no 24.2 but for ( composite ) 24.2.16 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( only supply ) 24.2.17 as per item no 24.2 but for 95 sq. mm as per item no 24.2 but for ( only labour ) 24.2.18 as per item no 24.2 but for 95 sq. mmas per item no 24.2 but for ( composite ) 24.2.19 as per item no 24.2 but for 120 sq. mmas per item no 24.2 but for ( only supply ) 24.2.20 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( only labour ) 24.2.21 as per item no 24.2 but for 120 sq. mm as per item no 24.2 but for ( composite ) 24.2.22 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only supply ) 24.2.23 as per item no 24.2 but for 150 sq. mmas per item no 24.2 but for ( only labour ) 24.2.24 as per item no 24.2 but for 150 sq. mm as per item no 24.2 but for ( composite ) 24.2.25 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( only supply ) 24.2.26 as per item no 24.2 but for 185 sq. mm as per item no 24.2 but for ( only labour ) 24.2.27 as per item no 24.2 but for 185 sq. mmas per item no 24.2 but for ( composite ) 24.2.28 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( only supply ) 24.2.29 as per item no 24.2 but for 240 sq. mm as per item no 24.2 but for ( only labour ) 24.2.30 as per item no 24.2 but for 240 sq. mmas per item no 24.2 but for ( composite ) 24.2.31 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( only supply ) 24.2.32 as per item no 24.2 but for 300 sq. mm as per item no 24.2 but for ( only labour ) 24.2.33 as per item no 24.2 but for 300 sq. mmas per item no 24.2 but for ( composite ) 24.2.34 as per item no 24.2 but for 400 sq. mmas per item no 24.2 but for ( only supply ) 24.2.35 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( only labour ) 24.2.36 as per item no 24.2 but for 400 sq. mm as per item no 24.2 but for ( composite ) 24.3 supplying & erecting crimping type aluminium lugs confirming to is suitable for various core sizes evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manners along with lug crimping pest etc all as directed by e i c, es. 24.3.1 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only supply ) 24.3.2 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( only labour ) 24.3.3 supplying & erecting crimping type al lugs confirming to is suitable for cables up to 16 sq. mm evenly crimped with high pressure tools & connected to switch gear terminals with brass / cadmium plated nut bolts in an approved manner.all as directed by o i c, es ( composite ) 24.3.4 as per item no 24.3 but for 25 sq. mm as per item no 24.3 but for ( only supply ) 25.1 flexible cable / borewell cablesupply & fixing of white / black colour pvc insulation of various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc. all as directed by o i c, es. 25.1.1 3 x 1.5 sq. mm flexible cable ( only supply ) 25.1.2 3 x 1.5 sq. mm flexible cable ( only labour ) 25.1.3 3 x 1.5 sq. mm flexible cable ( composite ) 25.1.4 3 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.5 3 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.6 3 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.7 3 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.8 3 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.9 3 x 4 sq. mm pvc flexible cable ( composite ) ) 25.1.10 2 x 1.5 sq. mm pvc flexible cable ( only supply ) 25.1.11 2 x 1.5 sq. mm pvc flexible cable ( only labour ) 25.1.12 2 x 1.5 sq. mm pvc flexible cable ( composite ) 25.1.13 2 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.14 2 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.15 2 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.16 4 x 2.5 sq. mm pvc flexible cable ( only supply ) 25.1.17 4 x 2.5 sq. mm pvc flexible cable ( only labour ) 25.1.18 4 x 2.5 sq. mm pvc flexible cable ( composite ) 25.1.19 4 x 4 sq. mm pvc flexible cable ( only supply ) 25.1.20 4 x 4 sq. mm pvc flexible cable ( only labour ) 25.1.21 4 x 4 sq. mm pvc flexible cable ( composite ) 25.2 supply & fixing of pvc insulated various sizes of flexible cables as required with necessary fixing arrangement, connection at the both the end using suitable lugs etc for bore well connection, all as directed by o i c, es. 25.2.1 3c x 1.5 sq. mm cable ( only supply ) 25.2.2 3c x 1.5 sq. mm cable ( only labour ) 25.2.3 3c x 1.5 sq. mm cable ( composite ) 25.2.4 3c x 2.5 sq. mm cable ( only supply ) 25.2.5 3c x 2.5 sq. mm cable ( only labour ) 25.2.6 3c x 2.5 sq. mm cable ( composite ) 25.2.7 3c x 4 sq. mm cable ( only supply ) 25.2.8 3c x 4 sq. mm cable ( only labour ) 25.2.9 3c x 4 sq. mm cable ( composite ) 26 water level controller 26.1 supply, installation, testing & commissioning of water level controller for maintaining of desired level of water in water tank etc, having all sensing mechanium in place, as complete unit, with all other necessary arrangement of proper finctioning etc, all as per instruction and as per derection of e i c, es 26.1.1 automatic water level controller with sensor ( only supply ) 26.1.2 automatic water level controller with sensor ( only labour ) 26.1.3 automatic water level controller with sensor ( composite ) 26.1.4 sensor for water level controller ( only supply ) 26.1.5 sensor for water level controller ( only labour ) 26.1.6 sensor for water level controller ( composite ) 26.1.7 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.8 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.9 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 3 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.10 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 5.8 / 8.5 liters per sec. for head of 20 / 36 m and 65 mm suction / 50mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only supply ) 26.1.11 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( only labour ) 26.1.12 supplying and erecting centrifugal water pump ( monoblock ) , 415v, 3 phase, 50hz, a.c. supply, of 5 hp with discharge 2 / 4.1 liters per sec. for head of 36 / 52 m and 50mm suction / 40mm delivery pipe on provided cement concrete foundation as per specification and instruction of engg. in charge. ( composite ) 26.1.13 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.14 supplying and erecting submercible water pump set suitable for erection on open well of 5hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.15 supplying and erecting submercible water pump set suitable for erection on open well of 5 hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head 36m and discharge from 400 to 1600 ltrs per minute ( max. efficiency at 21 m head and 680 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 26.1.16 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only supply ) 26.1.17 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( only labour ) 26.1.18 supplying and erecting submercible water pump set suitable for erection on open well of required hp with 415v, 3 phase, 50hz, a.c. supply, having delivery head from 20 to 10m and discharge from 450 to 1600 ltrs per minute ( max. efficiency at 17 m head and 1250 ltr discharge ) and delivery pipe of necessary dia. erected with necessary h type clamp as per specification and instruction of engg. in charge. ( composite ) 27.1 earthingsupplying & installation of tinned copper strip / bare copper wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continity test etc & all as directed by engg. in charge. 27.1.1 8 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.2 8 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.3 8 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.4 10 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.5 10 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.6 10 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.7 12 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.8 12 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.9 12 swg tinned copper bare wire ( 1 run ) ( only composite ) 27.1.10 14 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.11 14 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.12 14 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.13 16 swg tinned copper bare wire ( 1 run ) ( only supply ) 27.1.14 16 swg tinned copper bare wire ( 1 run ) ( only labour ) 27.1.15 16 swg tinned copper bare wire ( 1 run ) ( composite ) 27.1.16 copper strip of size 25 x 3 mm ( 1 run ) ( only supply ) 27.1.17 copper strip of size 25 x 3 mm ( 1 run ) ( only labour ) 27.1.18 copper strip of size 25 x 3 mm ( 1 run ) ( composite ) 27.1.19 copper strip of size 25 x 5 mm ( 1 run ) ( only supply ) 27.1.20 copper strip of size 25 x 5 mm ( 1 run ) ( only labour ) 27.1.21 copper strip of size 25 x 5 mm ( 1 run ) ( composite ) 27.1.22 copper strip of size 50 x 6 mm ( 1 run ) ( only supply ) 27.1.23 copper strip of size 50 x 6 mm ( 1 run ) ( only labour ) 27.1.24 copper strip of size 50 x 6 mm ( 1 run ) ( composite ) 27.2 gi earthing strip supplying & installation of tinned gi strip / bare gi wire for earthing system fixed on wall / side of the trench / slab / coloum / beam along with clips / saddle and spacers etc. including end connection with crimping type copper lugs complete in all respect, with continuty test etc & all as directed by engg. in charge. 27.2.1 gi strip size 25 x 3 mm ( 1 run ) ( only supply ) 27.2.2 gi strip size 25 x 3 mm ( 1 run ) ( only labour ) 27.2.3 gi strip size 25 x 3 mm ( 1 run ) ( compsite ) 27.2.4 gi strip size 25 x 5 mm ( 1 run ) ( only supply ) 27.2.5 gi strip size 25 x 5 mm ( 1 run ) ( only labour ) 27.2.6 gi strip size 25 x 5 mm ( 1 run ) ( compsite ) 27.2.7 gi wire 8 swg, ( 1 run ) ( only supply ) 27.2.8 gi wire 8 swg, ( 1 run ) ( only labour ) 27.2.9 gi wire 8 swg, ( 1 run ) ( composite ) 27.3 earting stations / pits 27.3.1 maintenance of earthing pits treated type with charcoal , salt , water as per standard practice. 27.3.2 tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like cole, charcoal, salt, brass nut bolts & washers, watering arrangements, gi pipe ( b class ) , concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. etc. ( 2 nos, of neutral earthing of t / f, 2 nos. for t / f body earthing & 2 nos. for panel earthing ) hot dipped gi earth plate electrode 600 x 600 x 6.3 mm earth station 2.5 mtr below the ground level same as above as per drawing & specifications complete with all required materials like coke / charcoal, salts , brass nut bolts & washers, watering arrangement, gu pipe ( b class ) concrete / brick chamber, heavy duty cast iron cover plate & excavation in ground, refilling & removing of excess earth within a radius of 500 mtr.etc. scope also includes dewatering, shoring, & consolidation etc. ( composite ) 27.4 air terminator / lightening arrestor 27.4.1 air terminator consisting of 75 to 100 mm dia & 6 mm thick tin copper sphere with 5 nos of spikes of 6 mm dia, 100 mm long, 19 mm dia 600 mm long tinned copper rod 150 mm dia 10 mm thickness tinned copper flange, 200 x 200 x 10 mm tinned brass plate gi grouting bolts / anchor fasteners etc. ( composite ) 28.1 cable jointing straight through jointing for 1.1 kv pvc insulated al / copper conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.1.1 3.5 x 10 sq. mm copper ( only supply ) 28.1.2 3.5 x 10 sq. mm copper ( only labour ) 28.1.3 3.5 x 10 sq. mm copper ( composite ) 28.1.4 3.5 x 16 sq. mm copper ( only supply ) 28.1.5 3.5 x 16 sq. mm copper ( only labour ) 28.1.6 3.5 x 16 sq. mm copper ( composite ) 28.1.7 3.5 x 25 sq. mm copper ( only supply ) 28.1.8 3.5 x 25 sq. mm copper ( only labour ) 28.1.9 3.5 x 25 sq. mm copper ( composite ) 28.1.10 3.5 x 35 sq. mm copper ( only supply ) 28.1.11 3.5 x 35 sq. mm copper ( only labour ) 28.1.12 3.5 x 35 sq. mm copper ( composite ) 28.1.13 3.5 x 50 sq. mm copper ( only supply ) 28.1.14 3.5 x 50 sq. mm copper ( only labour ) 28.1.15 3.5 x 50 sq. mm copper ( composite ) 28.1.16 3.5 x 70 sq. mm copper ( only supply ) 28.1.17 3.5 x 70 sq. mm copper ( only labour ) 28.1.18 3.5 x 70 sq. mm copper ( composite ) 28.1.19 3.5 x 95 sq. mm copper ( only supply ) 28.1.20 3.5 x 95 sq. mm copper ( only labour ) 28.1.21 3.5 x 95 sq. mm copper ( composite ) 28.1.22 3.5 x 120 sq. mm copper ( only supply ) 28.1.23 3.5 x 120 sq. mm copper ( only labour ) 28.1.24 3.5 x 120 sq. mm copper ( composite ) 28.1.25 3.5 x 150 sq. mm copper ( only supply ) 28.1.26 3.5 x 150 sq. mm copper ( only labour ) 28.1.27 3.5 x 150 sq. mm copper ( composite ) 28.1.28 3.5 x 185 sq. mm copper ( only supply ) 28.1.29 3.5 x 185 sq. mm copper ( only labour ) 28.1.30 3.5 x 185 sq. mm copper ( composite ) 28.1.31 3.5 x 240 sq. mm copper ( only supply ) 28.1.32 3.5 x 240 sq. mm copper ( only labour ) 28.1.33 3.5 x 240 sq. mm copper ( composite ) 28.1.34 3.5 x 300 sq. mm copper ( only supply ) 28.1.35 3.5 x 300 sq. mm copper ( only labour ) 28.1.36 3.5 x 300 sq. mm copper ( composite ) 28.1.37 3.5 x 400 sq. mm copper ( only supply ) 28.1.38 3.5 x 400 sq. mm copper ( only labour ) 28.1.39 3.5 x 400 sq. mm copper ( composite ) 28.2 straight through jointing for 11 / 33 kv xlpe insulated al conductors cable including supply of all jointing materials like sleeves, tinned copper cable sockets / ferrules terminal protector comprising of insulating sleeves & grommets etc similar to pre molded push on type raychem cable termination & earthing complete as required & tested as per relevant is specification including testing & commissioning all as per instruction e i c. 28.2.1 as described above, 11kv, 3 x 240 sq.mm xlpe ( only supply ) 28.2.2 as described above, 11kv, 3 x 240 sq.mm xlpe ( only labour ) 28.2.3 as described above, 11kv, 3 x 240 sq.mm xlpe ( composite ) 28.2.4 as described above, 33kv, 3 x 300 sq. mm xlpe ( only supply ) 28.2.5 as described above, 33kv, 3 x 300 sq. mm xlpe ( only labour ) 28.2.6 as described above, 33kv, 3 x 300 sq. mm xlpe ( composite ) 29.1 switch board for ac pointfabrication / & supply, installation. testing & commissioning of ms box made out of 16 / 14 swg ms sheet with removable top cover of 3 mm white hylam sheet / ms sheet with screws, cup washer etc. & complete concealed in wall with their following accessories mounted on it & their inter connection with 2.5 / 4 sq. mm pvc insulated copper cord wire. all as required & as directed by o i c, es. 29.1.1 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only supply ) 29.1.2 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( only labour ) 29.1.3 20 amps 2 pin + earth ( as 20 ) reroll type crompton / mds or approved make metalic sockets 1 no / / / / 20 amps mds make dp mcb with separate neutral link as controling s / w 1no. / / / / 20 amps crompton make metalic top 1 no. for above socket. ( composite ) 29.1.4 as per item no 29.1 but for 40 amps dp mcb & socket ( only supply ) 29.1.5 as per item no 29.1 but for 40 amps dp mcb & socket ( only labour ) 29.1.6 as per item no 29.1 but for 40 amps dp mcb & socket ( composite ) 29.1.7 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only supply ) 29.1.8 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( only labour ) 29.1.9 32 amps 4 pin + earth reroll type crompton / mds / cutler hammer or approved make metallic socket. 1 no. / 32 amps mds make tpn mcb as a controlling s / w – 1 no / 32 amps crompton / mds / cutler hammer make top ( composite ) 29.2 replacement for item no 29.1 29.2.1 replacement of 20 amps, reroll type metallic spn sockets ( only supply ) 29.2.2 replacement of 20 amps, reroll type metallic spn sockets ( only labour ) 29.2.3 replacement of 20 amps, reroll type metallic spn sockets ( composite ) 29.2.4 replacement of 32 amps, reroll type metallic spn sockets ( only supply ) 29.2.5 replacement of 32 amps, reroll type metallic spn sockets ( only labour ) 29.2.6 replacement of 32 amps, reroll type metallic spn sockets ( composite ) 29.2.7 replacement of 40 amps, reroll type metallic spn sockets ( only supply ) 29.2.8 replacement of 40 amps, reroll type metallic spn sockets ( only labour ) 29.2.9 replacement of 40 amps, reroll type metallic spn sockets ( composite ) 29.2.10 replacement of 63 amps, reroll type metallic spn sockets ( only supply ) 29.2.11 replacement of 63 amps, reroll type metallic spn sockets ( only labour ) 29.2.12 replacement of 63 amps, reroll type metallic spn sockets ( composite ) 29.2.13 supply & fixing metallic top for 10 amps 2p+e ( only supply ) 29.2.14 supply & fixing metallic top for 10 amps 2p+e ( only labour ) 29.2.15 supply & fixing metallic top for 10 amps 2p+e ( composite ) 29.2.16 as per item no 29.2.13 but for 20 amps ( only supply ) 29.2.17 as per item no 29.2.13 but for 20 amps ( only labour ) 29.2.18 as per item no 29.2.13 but for 20 amps ( composite ) 29.2.19 as per item no 29.2.13 but for 32 amps ( only supply ) 29.2.20 as per item no 29.2.13 but for 32 amps ( only labour ) 29.2.21 as per item no 29.2.13 but for 32 amps ( composite ) 29.2.22 as per item no 29.2.13 but for 40 amps ( only supply ) 29.2.23 as per item no 29.2.13 but for 40 amps ( only labour ) 29.2.24 as per item no 29.2.13 but for 40 amps ( composite ) 29.2.25 supplying & fixing metallic top 32 amps, 3 p + e ( only supply ) 29.2.26 supplying & fixing metallic top 32 amps, 3 p + e ( only labour ) 29.2.27 supplying & fixing metallic top 32 amps, 3 p + e ( composite ) 29.2.28 spike guard of approved make for computer ( only supply ) 29.2.29 heavy duty spike guard of approved make for equipments ( only supply ) 30.1 distribution boards providing & erecting distribution made out of 2 mm thick ( in case of fabrication ) ms crca sheet with concealed hinges, mounted on ms angle frame & grouted on the wall / fixed on the coloum with anchor fastener with earthing terminal, neutral link, interconnection with adequate size of bus bar / wires, interior of the db shall be covered with 3 mm thick frp sheet with necessary cut out, neoprene gasket, painting with seven tank metal treatment process ( shade to be got approved ) / powder coating all as per instructions of e i c, complete in all respect. 30.1.1.1 lighting distribution boardsall as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only supply ) 30.1.1.2 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( only labour ) 30.1.1.3 all as per item no 30.1 for 40 amps tpn mcb 1 no / / / .25amps dp elcb ( 30ma ) 3 nos / / / .6 amps sp mcb ( 8 ways ) 24 nos. ( composite ) 30.1.1.4 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only supply ) 30.1.1.5 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( only labour ) 30.1.1.6 all as per item no 30.1 for 40 amps dp elmcb 1 no. / / / 6 / 16 amps sp mcb 8 nos. ( composite ) 30.1.2 power distribution boards 30.1.2.1 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only supply ) 30.1.2.2 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( only labour ) 30.1.2.3 all as per item no 30.1 for 63 amps tpn mcb 1 no. / / / 40 amps dp elcb ( 30 ma ) 3 nos / / / 16 amps sp mcb ( 8ways ) 24 nos. ( composite ) 30.1.2.4 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only supply ) 30.1.2.5 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( only labour ) 30.1.2.6 all as per item no 30.1 for 100 amps tpn mcb / isolator 1 no. / / / 63 amps dp elcb ( 100 ma ) 3 nos. / / / 16 amps sp mcb ( 12 ways ) 36 nos. ( composite ) 30.1.3 ready made distribution boards supply, erection, testing & commissioning of sheet metal powered coated distribution boards inclusive of mcbs with bus bar, neutral link & connection wire set etc of mds / siemens make confirming to ip 42. all as required & directed by o i c, es with prior approval. 30.1.3.1 spn 4 way ( only supply ) 30.1.3.2 spn 4 way ( only labour ) 30.1.3.3 spn 4 way ( composite ) 30.1.3.4 spn 6 way ( only supply ) 30.1.3.5 spn 6 way ( only labour ) 30.1.3.6 spn 6 way ( composite ) 30.1.3.7 spn 8 way ( only supply ) 30.1.3.8 spn 8 way ( only labour ) 30.1.3.9 spn 8 way ( composite ) 30.1.3.10 spn 12 way ( only supply ) 30.1.3.11 spn 12 way ( only labour ) 30.1.3.12 spn 12 way ( composite ) 30.1.3.13 tpn 4 way ( only supply ) 30.1.3.14 tpn 4 way ( only labour ) 30.1.3.15 tpn 4 way ( composite ) 30.1.3.16 tpn 6 way ( only supply ) 30.1.3.17 tpn 6 way ( only labour ) 30.1.3.18 tpn 6 way ( composite ) 30.1.3.19 tpn 8 way ( only supply ) 30.1.3.20 tpn 8 way ( only labour ) 30.1.3.21 tpn 8 way ( composite ) 30.1.3.22 tpn 12 way ( only supply ) 30.1.3.23 tpn 12 way ( only labour ) 30.1.3.24 tpn 12 way ( composite ) 30.1.4.1 aluminum anodized name plates for circuit identification with prior approval. ( only supply ) 30.1.4.2 aluminum anodized name plates for circuit identification with prior approval. ( only labour ) 30.1.4.3 aluminum anodized name plates for circuit identification with prior approval. ( only composite ) 31.1 pvc boardssupply, installation of suitable size of pvc board of approved make with necessary fixing arrangement doene by suitable screwing on any kind of surface for installing accessories like switches, sockets, regulators oe nay other similar application as per the instructions and as directed by e i c, es 31.1.1 4 x 4 ( only supply ) 31.1.2 4 x 4 ( only labour ) 31.1.3 4 x 4 ( composite ) 31.1.4 4 x 6 ( only supply ) 31.1.5 4 x 6 ( only labour ) 31.1.6 4 x 6 ( composite ) 31.1.7 4 x 7 ( only supply ) 31.1.8 4 x 7 ( only labour ) 31.1.9 4 x 7 ( composite ) 31.1.10 6 x 6 ( only supply ) 31.1.11 6 x 6 ( only labour ) 31.1.12 6 x 6 ( composite ) 31.1.13 6 x 8 ( only supply ) 31.1.14 6 x 8 ( only labour ) 31.1.15 6 x 8 ( composite ) 31.1.16 8 x 10 ( only supply ) 31.1.17 8 x 10 ( only labour ) 31.1.18 8 x 10 ( composite ) 31.1.19 10 x 12 ( only supply ) 31.1.20 10 x 12 ( only labour ) 31.1.21 10 x 12 ( composite ) 31.1.22 12 x 12 ( only supply ) 31.1.23 12 x 12 ( only labour ) 31.1.24 12 x 12 ( composite ) 31.1.25 3.5 x 6 ( only supply ) 31.1.26 3.5 x 6 ( only labour ) 31.1.27 3.5 x 6 ( composite ) 31.1.28 3.5 x 8 ( only supply ) 31.1.29 3.5 x 8 ( only labour ) 31.1.30 3.5 x 8 ( composite ) 31.1.31 3.5 x 10 ( only supply ) 31.1.32 3.5 x 10 ( only labour ) 31.1.33 3.5 x 10 ( composite ) 31.1.34 3.5 x 12 ( only supply ) 31.1.35 3.5 x 12 ( only labour ) 31.1.36 3.5 x 12 ( composite ) 32 mcbs / mccbs / sfus / isolators 32.1 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box & lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.1.1. as per item no 32.1 for– 32 a ( only supply ) 32.1.2 as per item no 32.1 for– 32 a ( only labour ) 32.1.3. as per item no 32.1 for– 32 a ( composite ) 32.1.4 as per item no 32.1 but for– 63 a ( only supply ) 32.1.5. as per item no 32.1 but for– 63 a ( only labour ) 32.1.6 as per item no 32.1 but for– 63 a ( composite ) 32.1.7. as per item no 32.1 but for– 100 a ( only supply ) 32.1.8 as per item no 32.1 but for– 100 a ( only labour ) 32.1.9 as per item no 32.1 but for– 100 a ( composite ) 32.1.10 as per item no 32.1 but for– 200 a ( only supply ) 32.1.11. as per item no 32.1 but for– 200 a ( only labour ) 32.1.12 as per item no 32.1 but for– 200 a ( composite ) 32.1.13 as per item no 32.1 but for 250 a ( only supply ) 32.1.14 as per item no 32.1 but for 250 a ( only labour ) 32.1.15 as per item no 32.1 but for 250 a ( composite ) 32.1.16 as per item no 32.1 but for 400 a ( only supply ) 32.1.17 as per item no 32.1 but for 400 a ( only labour ) 32.1.18 as per item no 32.1 but for 400 a ( composite ) 32.1.19 as per item no 32.1 but for 630 a ( only supply ) 32.1.20 as per item no 32.1 but for 630 a ( only labour ) 32.1.21 as per item no 32.1 but for 630 a ( composite ) 32.2 supply, fixing, testing & commissioning of c curve mcb with enclosure & connected with provided leads on incoming & outgoing side with all fixing arrangemet etc duly completed approved manner, all as per instruction and as directed by e i c, es. 32.2.1 as per item no 32.2 for– 6 a sp ( only supply ) 32.2.2 as per item no 32.2 for– 6 a sp ( only labour ) 32.2.3 as per item no 32.2 for– 6 a sp ( composite ) 32.2.4 as per item no 32.2 but for– 16 a sp ( only supply ) 32.2.5 as per item no 32.2 but for– 16 a sp ( only labour ) 32.2.6 as per item no 32.2 but for– 16 a sp ( composite ) 32.2.7 as per item no 32.2 but for– 20 a sp ( only supply ) 32.2.8 as per item no 32.2 but for– 20 a sp ( only labour ) 32.2.9 as per item no 32.2 but for– 20 a sp ( composite ) 32.2.10 as per item no 32.2 but for– 32 a sp ( only supply ) 32.2.11 as per item no 32.2 but for– 32 a sp ( only labour ) 32.2.12 as per item no 32.2 but for– 32 a sp ( composite ) 32.2.13 as per item no 32.2 but for– 20 a dp ( only supply ) 32.2.14 as per item no 32.2 but for– 20 a dp ( only labour ) 32.2.15 as per item no 32.2 but for– 20 a dp ( composite ) 32.2.16 as per item no 32.2 but for– 32 a dp ( only supply ) 32.2.17 as per item no 32.2 but for– 32 a dp ( only labour ) 32.2.18 as per item no 32.2 but for– 32 a dp ( composite ) 32.2.19 as per item no 32.2 but for– 40 a dp ( only supply ) 32.2.20 as per item no 32.2 but for– 40 a dp ( only labour ) 32.2.21 as per item no 32.2 but for– 40 a dp ( composite ) 32.2.22 as per item no 32.2 but for– 63 a dp ( only supply ) 32.2.23 as per item no 32.2 but for– 63 a dp ( only labour ) 32.2.24 as per item no 32.2 but for– 63 a dp ( composite ) 32.2.25 as per item no 32.2 but for– 32 a tp ( only supply ) 32.2.26 as per item no 32.2 but for– 32 a tp ( only labour ) 32.2.27 as per item no 32.2 but for– 32 a tp ( composite ) 32.2.28 as per item no 32.2 but for– 40 a tp ( only supply ) 32.2.29 as per item no 32.2 but for– 40 a tp ( only labour ) 32.2.30 as per item no 32.2 but for– 40 a tp ( composite ) 32.2.31 all as per item no 30.1 for 63 a tp ( only supply ) 32.2.32 as per item no 32.2 but for– 63 a tp ( only labour ) 32.2.33 as per item no 32.2 but for– 63 a tp ( composite ) 32.2.34 as per item no 32.2 but for32 a, 4 pole ( only supply ) 32.2.35 as per item no 32.2 but for32 a, 4 pole ( only labour ) 32.2.36 as per item no 32.2 but for32 a, 4 pole ( composite ) 32.2.37 as per item no 32.2 but for40 a, 4 pole ( only supply ) 32.2.38 as per item no 32.2 but for40 a, 4 pole ( only labour ) 32.2.39 as per item no 32.2 but for40 a, 4 pole ( composite ) 32.2.40 as per item no 32.2 but for63 a, 4 pole ( only supply ) 32.2.41 as per item no 32.2 but for63 a, 4 pole ( only labour ) 32.2.42 as per item no 32.2 but for63 a, 4 pole ( composite ) 32.2.43 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only supply ) 32.2.44 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( only labour ) 32.2.45 as per item no 32.2 but for 100 a, 4 pole isolator ( mcb type ) ( composite ) 32.3 supply, fixing, testing & commissioning of tpn sfu in sheet steel enclosure of reputed make with suitable hrc fuses and to be connected with provided list with all necessary fixing arrangement as as per instrructions and as directed by e i c, es. 32.3.1 32 a, 415 v, ac ( only supply ) 32.3.2 32 a, 415 v, ac ( only labour ) 32.3.3 32 a, 415 v, ac ( composite ) 32.3.4 63 a, 415 v, ac ( only supply ) 32.3.5 63 a, 415 v, ac ( only labour ) 32.3.6 63 a, 415 v, ac ( composite ) 32.3.7 125 a, 415 v, ac ( only supply ) 32.3.8 125 a, 415 v, ac ( only labour ) 32.3.9 125 a, 415 v, ac ( composite ) 32.3.10 200 a, 415 v, ac ( only supply ) 32.3.11 200 a, 415 v, ac ( only labour ) 32.3.12 200 a, 415 v, ac ( composite ) 32.3.14 250 a, 415 v, ac ( only labour ) 32.3.15 250 a, 415 v, ac ( composite ) 32.3.16 315 a, 415 v, ac ( only supply ) 32.3.17 315 a, 415 v, ac ( only labour ) 32.3.18 315 a, 415 v, ac ( composite ) 32.3.19 400 a, 415 v, ac ( only supply ) 32.3.20 400 a, 415 v, ac ( only labour ) 32.3.21 400 a, 415 v, ac ( composite ) 32.3.22 630 a, 415 v, ac ( only supply ) 32.3.23 630 a, 415 v, ac ( only labour ) 32.3.24 630 a, 415 v, ac ( composite ) 32.4 supply, fixing, testing & commissioning of mccb of reputed make with metal enclosure box lsi protection , 35 ka phase seperator , and fixing accessories connected with provided leads on incoming & outgoing side duly with necessary fixing arrangement etc completed in an approved manner, all as per instructions and as directed by e i c, es. 32.4.1 as per item no 32.4 for 1000 a ( only supply ) 32.4.2 as per item no 32.4 for 1000 a ( only labour ) 32.4.3 as per item no 32.4 for 1000 a ( composite ) 32.4.4 as per item no 32.4 but for 800 a ( only supply ) 32.4.5 as per item no 32.4 but for 800 a ( only labour ) 32.4.6 as per item no 32.4 but for 800 a ( composite ) 32.5 providing, fixing, testing & commissioning of reputed make tpn isolator with provided leads incoming & outgoing side with all necessary fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.5.1 as per item no 32.5 for 400 a ( only supply ) 32.5.2 as per item no 32.5 for 400 a ( only labour ) 32.5.3 as per item no 32.5 for 400 a ( composite ) 32.5.4 as per item no 32.5 but for 250 a ( only supply ) 32.5.5 as per item no 32.5 but for 250 a ( only labour ) 32.5.6 as per item no 32.5 but for 250 a ( composite ) 32.5.7 as per item no 32.5 but for 125 a ( only supply ) 32.5.8 as per item no 32.5 but for 125 a ( only labour ) 32.5.9 as per item no 32.5 but for 125 a ( composite ) 32.5.10 as per item no 32.5 but for 63 a ( only supply ) 32.5.11 as per item no 32.5 but for 63 a ( only labour ) 32.5.12 as per item no 32.5 but for 63 a ( composite ) 32.6 providing, fixing, testing & commissioning of reputed make tpn sfu with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.6.1 as per item no 32.6 for 630 a ( only supply ) 32.6.2 as per item no 32.6 for 630 a ( only labour ) 32.6.3 as per item no 32.6 for 630 a ( composite ) 32.6.4 as per item no 32.6 but for 400 a ( only supply ) 32.6.5 as per item no 32.6 but for 400 a ( only labour ) 32.6.6 as per item no 32.6 but for 400 a ( composite ) 32.6.7 as per item no 32.6 but for 250 a ( only supply ) 32.6.8 as per item no 32.6 but for 250 a ( only labour ) 32.6.9 as per item no 32.6 but for 250 a ( composite ) 32.6.10 as per item no 32.6 but for 125 a ( only supply ) 32.6.11 as per item no 32.6 but for 125 a ( only labour ) 32.6.12 as per item no 32.6 but for 125 a ( composite ) 32.6.13 as per item no 32.6 but for 200 a ( only supply ) 32.6.14 as per item no 32.6 but for 200 a ( only labour ) 32.6.15 as per item no 32.6 but for 200 a ( composite ) 32.6.16 as per item no 32.6 but for 63 a ( only supply ) 32.6.17 as per item no 32.6 but for 63 a ( only labour ) 32.6.18 as per item no 32.6 but for 63 a ( composite ) 32.6.19 as per item no 32.6 but for 32 a ( only supply ) 32.6.20 as per item no 32.6 but for 32 a ( only labour ) 32.6.21 as per item no 32.6 but for 32 a ( composite ) 32.7 providing, fixing, testing & commissioning of reputed make tpn mcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner all asper instructions and as diredtec by e i c, es. 32.7.1 all as per item no 32.7 for 63 a ( only supply ) 32.7.2 all as per item no 32.7 for 63 a ( only labour ) 32.7.3 all as per item no 32.7 for 63 a ( composite ) 32.7.4 all as per item no 32.7 for 32 a ( only supply ) 32.7.5 all as per item no 32.7 for 32 a ( only labour ) 32.7.6 all as per item no 32.7 for 32 a ( composite ) 32.8 providing, fixing, testing & commissioning of reputed dp mcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es. 32.8.1 all as per item no 32.8 for 63 a ( only supply ) 32.8.2 all as per item no 32.8 for 63 a ( only labour ) 32.8.3 all as per item no 32.8 for 63 a ( composite ) 32.8.4 all as per item no 32.8 but for 40 a ( only supply ) 32.8.5 all as per item no 32.8 but for 40 a ( only labour ) 32.8.6 all as per item no 32.8 but for 40 a ( composite ) 32.8.7 all as per item no 32.8 but for 32 a ( only supply ) 32.8.8 all as per item no 32.8 but for 32 a ( only labour ) 32.8.9 all as per item no 32.8 but for 32 a ( composite ) 32.8.10 all as per item no 32.8 but for 20 a ( only supply ) 32.8.11 all as per item no 32.8 but for 20 a ( only labour ) 32.8.12 all as per item no 32.8 but for 20 a ( composite ) 32.8.13 all as per item no 32.8 but for 16 a ( only supply ) 32.8.14 all as per item no 32.8 but for 16 a ( only labour ) 32.8.15 all as per item no 32.8 but for 16 a ( composite ) 32.9 providing, fixing, testing & commissioning of reputed make dp elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner all as per instructions and as directed by e i c, es 32.9.1 all as per item no 32.9 for 63 a ( only supply ) 32.9.2 all as per item no 32.9 for 63 a ( only labour ) 32.9.3 all as per item no 32.9 for 63 a ( composite ) 32.9.4 all as per item no 32.9 but for 40 a ( only supply ) 32.9.5 all as per item no 32.9 but for 40 a ( only labour ) 32.9.6 all as per item no 32.9 but for 40 a ( composite ) 32.9.7 all as per item no 32.9 but for 25 a ( only supply ) 32.9.8 all as per item no 32.9 but for 25 a ( only labour ) 32.9.9 all as per item no 32.9 but for 25 a ( composite ) 32.10.a providing, fixing, testing & commissioning of reputed make 4 pole elcb with provided leads on incoming & outgoing side with fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es. 32.10.1 all as per item no 32.10 for 63 a ( only supply ) 32.10.2 all as per item no 32.10 for 63 a ( only labour ) 32.10.3 all as per item no 32.10 for 63 a ( composite ) 32.10.4 all as per item no 32.10 but for 40 a ( only supply ) 32.10.5 all as per item no 32.10 but for 40 a ( only labour ) 32.10.6 all as per item no 32.10 but for 40 a ( composite ) 32.11 providing, fixing, testing & commissioning of reputed make sp mcb with provided leads on incoming & outgoing side with fixing arrangementduly completed in approved manner all as per instructions and as directed by e i c, es. 32.11.1 all as per item no 32.11 for 40 / 63a ( only supply ) 32.11.2 all as per item no 32.11 for 40 / 63a ( only labour ) 32.11.3 all as per item no 32.11 for 40 / 63a ( composite ) 32.11.4 all as per item no 32.11 but for 32 a ( only supply ) 32.11.5 all as per item no 32.11 but for 32 a ( only labour ) 32.11.6 all as per item no 32.11 but for 32 a ( composite ) 32.11.7 all as per item no 32.11 but for 20 a ( only supply ) 32.11.8 all as per item no 32.11 but for 20 a ( only labour ) 32.11.9 all as per item no 32.11 but for 20 a ( composite ) 32.11.10 all as per item no 32.11 but for 16 a ( only supply ) 32.11.11 all as per item no 32.11 but for 16 a ( only labour ) 32.11.12 all as per item no 32.11 but for 16 a ( composite ) 32.11.13 all as per item no 32.11 but for 6 a ( only supply ) 32.11.14 all as per item no 32.11 but for 6 a ( only labour ) 32.11.15 all as per item no 32.11 but for 6 a ( composite ) 32.12 providing, fixing, testing & commissioning of reputed make tpn mcb+elcb with provided leads on incoming & outgoing side with necessary fixing arrangement duly completed in approved manner as per instructions and as directed by e i c, es 32.12.1 all as per item no 32.12 for 32 a ( only supply ) 33.1 ct / pt and other panel componentsproviding, fixing, testing & commissioning of reputed make ct with provided bus bar on incoming & leads on outgoing side duly completed in approved manner. class 1, 15 va, resin cast, bar primary type. 33.2 supply, fixing, testing and commissioning of various sizes of annunciator panel as mentioned below with test, accepts, reset push button, supply on indication with necessary fixing arrangement, all as per instructions and as directed by e i c, es. ( prior approval is required ) 33.3 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only supply ) 33.3.1 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110 / root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( only labour ) 33.3.2 providing 33 kv resin cast type pt for 33 kv panel. ratio 33kv / 22 kv / root3 / 110root3 / 110 / root3, burden 100va / 50 va, class 1 / 3p, h.s.v 36 kv, insulation 75 / 170 kvp ( composite ) 33.4 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only supply ) 33.4.1 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only labour ) 33.4.2 providing 11 kv resin cast type pt for 11 kv panel. ratio 11 kv / root3 / 110 / root3, burden 100 va, class 1, h.s.v 12 kv insulation level 28 / 75 kvp ( only composite ) 33.5 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.5.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.5.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.6 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 33.6.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 33.6.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 amps.burdun 15 va, class 1 5p10, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 33.7 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.7.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.7.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5 5.burdun 15 va, class 1 5p10 ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.8 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only supply ) 33.8.1 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( only labour ) 33.8.2 providing 11 kv resin cast ct for 11 kv panel.ratio 600 300 / 5 5.burdun 15 va, class ps, h.s.v 12 kv, insulation level 28 / 75 kvp ( composite ) 33.9 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.9.1 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.9.2 providing 33kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 33.10.a providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only supply ) 33.10.1 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( only labour ) 33.10.2 providing 11kv, 3 amps, eshwari or equivalent make ht pt fuse ( composite ) 34.1 panel accessories providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only supply ) 34.1.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( only labour ) 34.1.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 240 deg. scale taught band type for various ct ratings. ( composite ) 34.2.0 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only supply ) 34.2.1 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg. scale mi type for various ct ratings. ( only labour ) 34.2.2 providing, fixing, testing & commissioning of ammeter 144 x 144 mm size, 90 deg.scale mi type for various ct ratings. ( composite ) 34.2.3 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.4 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.5 providing, fixing, testing & commissioning of ammeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.2.6 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only supply ) 34.2.7 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( only labour ) 34.2.8 providing, fixing, testing & commissioning of voltmeter 96 x 96 mm size, 90 deg.scale mi type for various ct ratings. ( item no. 8. ) ( composite ) 34.3.a providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only supply ) 34.3.1 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( only labour ) 34.3.2 providing, fixing, testing & commissioning of pt, 415 / 110 v ( 10 va ) ( composite ) 34.4 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only supply ) 34.4.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( only labour ) 34.4.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 240 deg. scale taught band type for variousct ratings. ( item no. 8. ) ( composite ) 34.5 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( only supply ) 34.5.1 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg.scale mi type for above said ct ratings. ( item no. 8. ) ( only labour ) 34.5.2 providing, fixing, testing & commissioning of voltmeter 0 – 500 v, 144 x 144 mm size, 90 deg. scale mi type for above said ct ratings. ( item no. 8. ) ( composite ) 34.6 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only supply ) 34.6.1 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( only labour ) 34.6.2 providing, fixing, testing & commissioning of kwh+mdi 3 phase 4 wires. ( composite ) 34.6.3 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.4 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps.. ( only labour ) 34.6.5 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps. ( composite ) 34.6.6 providing, fixing, testing & commissioning of three phase direct reading digital kwh meter suitable up to 40amps. ( only supply ) 34.6.7 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( only labour ) 34.6.8 providing, fixing, testing & commissioning of single phase direct reading digital kwh meter suitable up to 40amps ( composite ) 34.7 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only supply ) 34.7.1 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( only labour ) 34.7.2 providing, fixing, testing & commissioning of digital pf meter, inclusivre of auxilaries ( composite ) 34.8 providing, fixing, testing & commissioning of analog pf meter ( only supply ) 34.8.1 providing, fixing, testing & commissioning of analog pf meter ( only labour ) 34.8.2 providing, fixing, testing & commissioning of analog pf meter ( composite ) 34.9 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only supply ) 34.9.1 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( only labour ) 34.9.2 providing, fixing, testing & commissioning of frequency meter, inclusive of auxiluries if any ( composite ) 34.10.a providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only supply ) 34.10.1 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( only labour ) 34.10.2 providing, fixing, testing & commissioning of selector switch for ammeter & voltmeter ( composite ) 34.11 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only supply ) 34.11.1 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( only labour ) 34.11.2 providing, fixing, testing & commissioning of breaker selector switch. 10 a, 3 pole, 3 way with off type srp 139 c ( composite ) 34.12 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only supply ) 34.12.1 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( only labour ) 34.12.2 providing, fixing, testing & commissioning of make breaker control switch. ( tnc switch ) ( composite ) 34.13 providing, fixing, testing & commissioning of auto / mannual selector switch ( only supply ) 34.13.1 providing, fixing, testing & commissioning of auto / mannual selector switch ( only labour ) 34.13.2 providing, fixing, testing & commissioning of auto / mannual selector switch ( only composite ) 34.14 providing, fixing, testing & commissioning of 2p2w rotary switch ( only supply ) 34.14.1 providing, fixing, testing & commissioning of 2p2w rotary switch ( only labour ) 34.14.2 providing, fixing, testing & commissioning of 2p2w rotary switch ( composite ) 34.15 providing, fixing, testing & commissioning of 3p3w rotary switch ( only supply ) 34.15.1 providing, fixing, testing & commissioning of 3p3w rotary switch ( only labour ) 34.15.2 providing, fixing, testing & commissioning of 3p3w rotary switch ( composite ) 34.16 providing, fixing, testing & commissioning of 1 way toggle switch ( only supply ) 34.16.1 providing, fixing, testing & commissioning of 1 way toggle switch ( only labour ) 34.16.2 providing, fixing, testing & commissioning of 1 way toggle switch ( composite ) 34.17 providing, fixing, testing & commissioning of 2 way toggle switch ( only supply ) 34.17.1 providing, fixing, testing & commissioning of 2 way toggle switch ( only labour ) 34.17.2 providing, fixing, testing & commissioning of 2 way toggle switch ( composite ) 34.18 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only supply ) 34.18.1 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( only labour ) 34.18.2 providing, fixing, testing & commissioning of indicating lamp, 48 v dc. ( composite ) 34.19 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only supply ) 34.19.1 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( only labour ) 34.19.2 providing, fixing, testing & commissioning of indicating lamp, 24 v dc. ( composite ) 34.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only supply ) 34.20.1 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( only labour ) 34.20.2 providing, fixing, testing & commissioning of indicating lamp, 230 v ac ( composite ) 34.21 providing, fixing, testing & commissioning of indicating lamp, led type. 34.21.1 for red, orange, yellow, off white, green coloured led lamp ( only supply ) 34.21.2 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.3 for red, orange, yellow, off white, green coloured led lamp ( composite ) 34.21.4 as per item no 34.21 but for blue coluored led lamp ( only supply ) 34.21.5 as per item no 34.21 but for blue coluored led lamp ( only labour ) 34.21.6 as per item no 34.21 but for blue coluored led lamp ( composite ) 34.21.7 providing and fixing of centrifugal switch ( only supply ) 34.21.8 providing and fixing of centrifugal switch ( only labour ) 34.21.9 providing and fixing of centrifugal switch ( composite ) 34.22 providing, fixing, testing & commissioning of push buttons ( only supply ) 34.22.1 providing, fixing, testing & commissioning of push buttons ( only labour ) 34.22.2 providing, fixing, testing & commissioning of push buttons ( composite ) 34.23 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only supply ) 34.23.1 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( only labour ) 34.23.2 providing, fixing, testing & commissioning of luminous type push button white colour with bulb. ( composite ) 34.24 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230 v ac. ( only supply ) 34.24.1 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( only labour ) 34.24.2 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 230v ac. ( composite ) 34.24.3 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only supply ) 34.24.4 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( only labour ) 34.24.5 providing, fixing, testing & commissioning of auxilary contactor with 2no + 2nc auxiliary contacts suitable for 24 / 48 v dc. ( composite ) 34.24.6 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only supply ) 34.24.7 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( only labour ) 34.24.8 providing, fixing, testing & commissioning of add on auxilary contact block with 1no + 1nc ( composite ) 34.25 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only supply ) 34.25.1 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( only labour ) 34.25.2 providing, fixing, testing & commissioning of auxilary contactor with 4no + 4nc auxiliary contacts. ( composite ) 34.26 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.26.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.26.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.27 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only supply ) 34.27.1 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( only labour ) 34.27.2 providing, fixing, testing & commissioning of auxilary relay suitable for 24 / 48 volts. ( composite ) 34.28 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only supply ) 34.28.1 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( only labour ) 34.28.2 providing, fixing, testing & commissioning of space heater of strip type 60 w, 240 v ac ( composite ) 34.29 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only supply ) 34.29.1 thermo stat for space heater 240 v ac, 30 deg. to 90 deg. ( only labour ) 34.29.2 thermo stat for space heatre 240 v ac, 30 deg. to 90 deg. ( composite ) 34.30 supply and fixing of 240 v ac, hooter cands make ( only supply ) 34.30.1 supply and fixing of240 v ac, hooter cands make ( only labour ) 34.30.2 supply and fixing of240 v ac, hooter cands make ( composite ) 34.31 providing 33 kv resin cast type ct for 33 kv panel. ratio 600 / 5 5 5 amps.burdun 15 va, class 1 / 5p10 / ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only supply ) 34.31.1 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( only labour ) 34.31.2 providing 33 kv resin cast type ct for 33 kv panel. ratio 200 / 5 5 5 amps.burdun 15 va, class 1 5p10 ps, h.s.v 36 kv, insulation level 75 / 170 kvp. ( composite ) 34.32 providing dc power pack with battery backup ( only supply ) 34.32.1 providing dc power pack with battery backup ( only labour ) 34.32.2 providing dc power pack with battery backup ( composite ) 35 electrical accessories supply, fixing, testing and commissioning of the following electrical accessories on the hylam sheet / modular plates / pvc board etc or as directed by wherever required including appropriate size of copper conductor of pvc wires interconnection using lugs, insulatin tape etc. in complete manner as directed by e i c, es with prior approval. procurement of these items shall be done in accordence with approved makes. approval shall be sought from e i c, es for other brand or make. in case of reeplacement, old / removed items shall be handed over to e i c, es as it is. agency has to supply material as per existing makes as site linke anchor / roma precision etc. 35.1.1 6 amp, , flush type s / w ( only supply ) 35.1.2 6 amp, , flush type s / w ( only labour ) 35.1.3 6 amp, , flush type s / w ( composite ) 35.1.4 6 amp, , 3 pin socket ( only supply ) 35.1.5 6 amp, , 3 pin socket ( only labour ) 35.1.6 6 amp, , 3 pin socket ( composite ) 35.1.7 16 amp, , switch ( only supply ) 35.1.8 16 amp, , switch ( only labour ) 35.1.9 16 amp, , switch ( composite ) 35.1.10 16 amp, , 3 pin socket ( only supply ) 35.1.11 16 amp, , 3 pin socket ( only labour ) 35.1.12 16 amp, , 3 pin socket ( composite ) 35.1.13 16 amp, , 5 pin socket ( only supply ) 35.1.14 16 amp, , 5 pin socket ( only labour ) 35.1.15 16 amp, , 5 pin socket ( composite ) 35.1.16 6 amp, top ( only supply ) 35.1.17 6 amp, top ( only labour ) 35.1.18 6 amp, top ( composite ) 35.1.19 16 amp, top ( only supply ) 35.1.20 16 amp, top ( only labour ) 35.1.21 16 amp, top ( composite ) 35.1.22 6 amp, two way switch , make precision ( only supply ) 35.1.23 6 amp, two way switch , make precision ( only labour ) 35.1.24 6 amp, two way switch , make precision ( composite ) 35.1.25 16 amp two way switch ( only supply ) 35.1.26 16 amp two way switch ( only labour ) 35.1.27 16 amp two way switch ( composite ) 35.1.28 16 amp, 5 pin, switch socket combination board ( only supply ) 35.1.29 16 amp, 5 pin, switch socket combination board ( only labour ) 35.1.30 16 amp, 5 pin, switch socket combination board ( composite ) 35.1.31 2x15a, 5pin, switch socket combination board ( only supply ) 35.1.32 2x15a, 5pin, switch socket combination board ( only labour ) 35.1.33 2x15a, 5pin, switch socket combination board ( composite ) 35.1.34 6 amp, bell push ( only supply ) , 35.1.35 6 amp, bell push ( only labour ) 35.1.36 6 amp, bell push ( composite ) 35.1.37 ceiling rose ( only supply ) 35.1.38 ceiling rose ( only labour ) 35.1.39 ceiling rose ( composite ) 35.1.40 angle holder ( only supply ) 35.1.41 angle holder ( only labour ) 35.1.42 angle holder ( composite ) 35.1.43 batten holder ( only supply ) 35.1.44 batten holder ( only labour ) 35.1.45 batten holder ( composite ) 35.1.46 bell with indication, reset push button ( only supply ) 35.1.47 bell with indication, reset push button ( only labour ) 35.1.48 bell with indication, reset push button ( composite ) 35.1.49 buzzer of any approved make ( only supply ) 35.1.50 buzzer of any approved make ( only labour ) 35.1.51 buzzer of any approved make ( composite ) 35.1.52 3 pin telephone socket, ( only supply ) 35.1.53 3 pin telephone socket, ( only labour ) 35.1.54 3 pin telephone socket, ( composite ) 35.1.55 telephone socket ( rj – 11 jack ) ( only supply ) 35.1.56 telephone socket ( rj – 11 jack ) ( only labour ) 35.1.57 telephone socket ( rj – 11 jack ) ( composite ) 35.1.58 rj 45 jack socket ( only supply ) 35.1.59 rj 45 jack socket ( only labour ) 35.1.60 rj 45 jack socket ( composite ) 35.1.61 rj 11 pin ( only supply ) 35.1.62 rj 11 pin ( only labour ) 35.1.63 rj 11 pin ( composite ) 35.1.64 rj 45 pin ( only supply ) 35.1.65 rj 45 pin ( only labour ) 35.1.66 rj 45 pin ( composite ) 35.1.67 telephone 3 pin plug top ( only supply ) 35.1.68 telephone 3 pin plug top ( only labour ) 35.1.69 telephone 3 pin plug top ( composite ) 35.1.70 tv socket ( only supply ) 35.1.71 tv socket ( only labour ) 35.1.72 tv socket ( composite ) 35.1.73 tv pin ( male+ female ) ( only supply ) 35.1.74 tv pin ( male+ female ) ( only labour ) 35.1.75 tv pin ( male+ female ) ( compositey ) 35.1.76 tv connector ( splitter ) 35.1.77 as per item no 35.1.76 for 2 way ( only supply ) 35.1.78 as per item no 35.1.76 for 2 way ( only labour ) 35.1.79 as per item no 35.1.76 for 2 way ( composite ) 35.1.80 as per item no 35.1.76 but for 3 way ( only supply ) 35.1.81 as per item no 35.1.76 but for 3 way ( only labour ) 35.1.82 as per item no 35.1.76 but for 3 way ( composite ) 35.1.83 as per item no 35.1.76 but for 4 way ( only supply ) 35.1.84 as per item no 35.1.76 but for 4 way ( only labour ) 35.1.85 as per item no 35.1.76 but for 4 way ( composite ) 35.1.86 tv cable gland for rj 11 ( only supply ) 35.1.87 tv cable gland for rj 11 ( only labour ) 35.1.88 tv cable gland for rj 11 ( composite ) 35.1.89 glass fuse, 2 a / 4a ( only supply ) 35.1.90 glass fuse, 2 a / 4a ( only labour. ) 35.1.91 glass fuse, 2 a / 4a ( composite ) 35.1.92 glass fuse 6a / 10 a ( only supply ) 35.1.93 glass fuse 6a / 10 a ( only labour ) 35.1.94 glass fuse 6a / 10 a ( composite ) 35.1.95 250 w, , ceiling fan regulator ( only supply ) 35.1.96 250 w, , ceiling fan regulator ( only labour ) 35.1.97 250 w, , ceiling fan regulator ( composite ) 35.1.98 300 w, , ceiling fan regulator ( only suppply ) 35.1.99 300 w, , ceiling fan regulator ( only labour ) 35.1.100 300 w, , ceiling fan regulator ( composite ) 35.1.101 750 w, , ceiling fan regulator ( only supply ) 35.1.102 750 w, , ceiling fan regulator ( only labur ) 35.1.103 750 w, , ceiling fan regulator ( composite ) 35.1.104 1000 w, , ceiling fan regulator ( only supply ) 35.1.105 1000 w, , ceiling fan regulator ( only labour ) 35.1.106 1000 w, ceiling fan regulator ( composite ) 35.1.107 iron connector flat / round ( only supply ) 35.1.108 iron connector flat / round ( only labour ) 35.1.109 iron connector flat / round ( composite ) 35.1.110 industrial alarm bell ( only supply ) 35.1.111 industrial alarm bell ( only labour ) 35.1.112 industrial alarm bell ( composite ) 35.1.113 25 amps, dp switch flush type with neon indication. ( only supply ) 35.1.114 25 amps, dp switch flush type with neon indication. ( only labour ) 35.1.115 25 amps, dp switch flush type with neon indication. ( composite ) 35.1.116 32 amps, dp switch flush type with neon indication ( only supply ) 35.1.117 32 amps, dp switch flush type with neon indication ( only labour ) 35.1.118 32 amps, dp switch flush type with neon indication ( composite ) 35.1.119 glass for halogen fittings. ( only supply ) 35.1.120 glass for halogen fittings. ( only labour ) 35.1.121 glass for halogen fittings. ( composite ) 35.1.122 speed regulator h 70 k ohm ( only supply ) 35.1.123 speed regulator h 70 k ohm ( only labour ) 35.1.124 speed regulator h 70 k ohm ( composite ) 35.1.125 regulator for hoods as per sample ) ( only supply ) 35.1.126 regulator for hoods as per sample ) ( only labour ) 35.1.127 regulator for hoods in as per sample ) ( composite ) 35.1.128 16 amp, switch with red indicator ( only supply ) 35.1.129 16 amp, switch with red indicator ( only labour ) 35.1.130 16 amp, switch with red indicator ( composite ) 35.1.131 16 amp, switch with red indicator ( only supply ) 35.1.132 16 amp, switch with red indicator ( only labour ) 35.1.133 16 amp, switch with red indicator ( composiet ) 35.1.134 carbon brush for mixers etc. ( all sizes ) ( only supply ) 35.1.135 carbon brush for mixers etc. ( all sizes ) ( only labour ) 35.1.136 carbon brush for mixers etc. ( all sizes ) ( composite ) 35.1.137 carbon brush used for special purpose m / c ( only supply ) 35.1.138 carbon brush used for special purpose m / c ( only labour ) 35.1.139 carbon brush used for special purpose m / c ( composite ) 35.2 modular accesseries for anchor roma , legrand , as per existing at site matching or equivalent. general guidelines are as per item no 35.1 35.2.1 6 amp, switch ( only supply ) 35.2.2 6 amp, switch ( only labour ) 35.2.3 6 amp, switch ( composite ) 35.2.4 16 amp, switch ( only supply ) 35.2.5 16 amp, switch ( only labour ) 35.2.6 16 amp, switch ( composite ) 35.2.7 6 amp, two way switch ( only supply ) 35.2.8 6 amp, two way switch ( only labour ) 35.2.9 6 amp, two way switch ( composite ) 35.2.10 10 / 16 amp , two –way switch ( only supply ) 35.2.11 10 / 16 amp , two –way switch ( only labour ) 35.2.12 10 / 16 amp , two –way switch ( composite ) 35.2.13 6 amp, socket ( only supply ) 35.2.14 6 amp, socket ( only labour ) 35.2.15 6 amp, socket ( composite ) 35.2.16 16 amp, 3 pin socket ( only supply ) 35.2.17 16 amp, 3 pin socket ( only labour ) 35.2.18 16 amp, 3 pin socket ( compoxite ) 35.2.19 16 amp, 5 pin socket ( only supply ) 35.2.20 16 amp, 5 pin socket ( only labour ) 35.2.21 16 amp, 5 pin socket ( composite ) 35.2.22 telephone socket ( rj 11 ) ( only supply ) 35.2.23 telephone socket ( rj 11 ) ( only labour ) 35.2.24 telephone socket ( rj 11 ) ( composite ) 35.2.25 fan dimmer , 400 / 600w ( 0nly supply ) 35.2.26 fan dimmer, 400 / 600w ( 0nly labour ) 35.2.27 fan dimmer, 400 / 600w ( composite ) 35.2.28 1 way tv socket ( only supply ) 35.2.29 1 way tv socket ( only labour ) 35.2.30 1 way tv socket ( composite ) 35.2.31 2 way tv socket ( only supply ) 35.2.32 2 way tv socket ( only labour. ) 35.2.33 2 way tv socket ( composite ) 35.2.34 6 amp, switch with indicator ( only supply ) 35.2.35 6 amp, switch with indicator ( only labour ) 35.2.36 6 amp, switch with indicator ( composite ) 35.2.37 bell push ( only supply ) 35.2.38 bell push ( only labour ) 35.2.39 bell push ( composite ) 35.2.40 fan dimmer , 1000w ( 0nly supply ) 35.2.41 fan dimmer, 1000w ( 0nly labour ) 35.2.42 fan dimmer, 1000w ( composite ) 35.2.43 blank plate ( 0nly supply ) 35.2.44 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly supply ) 35.2.45 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( 0nly labour ) 35.2.46 6 to 32a sp mcb in provided modular box including face plate surface / conealed type ( composite ) 35.2.47 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly supply ) 35.2.48 16 to 32a dp mcb with modular box including face plate surface / conealed type ( 0nly labour ) 35.2.49 16 to 32a dp mcb with modular box including face plate surface / conealed type ( composite ) 35.2.50 rj 45 data socket ( 0nly supply ) 35.2.51 rj 45 data socket ( 0nly labour ) 35.2.52 rj 45 data socket ( composite ) 35.3 surface ( pvc ) boxes for modular accessories 35.3.1 1 or 2 way ( only supply ) 35.3.2 1 or 2 way ( only labour ) 35.3.3 1 or 2 way ( composite ) 35.3.4 3 way ( only supply ) 35.3.5 3 way ( only labour ) 35.3.6 3 way ( composite ) 35.3.7 4 way ( only supply ) 35.3.8 4 way ( only labour ) 35.3.9 4 way ( composite ) 35.3.10 6 way ( only supply ) 35.3.11 6 way ( only labour ) 35.3.12 6 way ( composite ) 35.3.13 8 way ( only supply ) 35.3.14 8 way ( only labour ) 35.3.15 8 way ( composite ) 35.3.16 8 way vertical / rectangular ( only supply ) 35.3.17 8 way vertical / rectangular ( only labour ) 35.3.18 8 way vertical / rectangular ( composite ) 35.3.19 12 way ( only supply ) 35.3.20 12 way ( only labour ) 35.3.21 12 way ( composite ) 35.3.22 16 way ( only supply ) 35.3.23 16 way ( only labour ) 35.3.24 16 way ( composite ) 35.3.25 18 way ( only supply ) 35.3.26 18 way ( only labour ) 35.3.27 18 way ( composite ) 35.4 concealed ( ms ) boxes for modular accessories & general accessories 35.4.1 1 or 2 way ( only supply ) 35.4.2 1 or 2 way ( only labour ) 35.4.3 1 or 2 way ( composite ) 35.4.4 3 way ( only supply ) 35.4.5 3 way ( only labour ) 35.4.6 3 way ( composite ) 35.4.7 4 way ( only supply ) 35.4.8 4 way ( only labour ) 35.4.9 4 way ( composite ) 35.4.10 6 way ( only supply ) 35.4.11 6 way ( only labour ) 35.4.12 6 way ( composite ) 35.4.13 8 way ( only supply ) 35.4.14 8 way ( only labour ) 35.4.15 8 way ( composite ) 35.4.16 8 way vertical / rectangular ( only supply ) 35.4.17 8 way vertical / rectangular ( only labour ) 35.4.18 8 way vertical / rectangular ( composite ) 35.4.19 12 way ( only supply ) 35.4.20 12 way ( only labour ) 35.4.21 12 way ( composite ) 35.4.22 16 way ( only supply ) 35.4.23 16 way ( only labour ) 35.4.24 16 way ( composite ) 35.4.25 18 way ( only supply ) 35.4.26 18 way ( only labour ) 35.4.27 18 way ( composite ) 35.5 face plate for modular accessories 35.5.1 1 way ( only supply ) 35.5.2 1 way ( only labour ) 35.5.3 1 way ( composite ) 35.5.4 2 way ( only supply ) 35.5.5 2 way ( only labour ) 35.5.6 2 way ( composite ) 35.5.7 3 way ( only supply ) 35.5.8 3 way ( only labour ) 35.5.9 3 way ( composite ) 35.5.10 4 way ( only supply ) 35.5.11 4 way ( only labour ) 35.5.12 4 way ( composite ) 35.5.13 6 way ( only supply ) 35.5.14 6 way ( only labour ) 35.5.15 6 way ( composite ) 35.5.16 8 way ( only supply ) 35.5.17 8 way ( only labour ) 35.5.18 8 way ( composite ) 35.5.19 8 way vertical / rectangular ( only supply ) 35.5.20 8 way vertical / rectangular ( only labour ) 35.5.21 8 way vertical / rectangular ( composite ) 35.5.22 12 way ( only supply ) 35.5.23 12 way ( only labour ) 35.5.24 12 way ( composite ) 35.5.25 16 way with or with indicator ( only supply ) 35.5.26 16 way with or with indicator ( only labour ) 35.5.27 16 way with or with indicator ( composite ) 35.5.28 18 way ( only supply ) 35.5.29 18 way ( only labour ) 35.5.30 18 way ( composite ) 35.5.31 cord less bell ( only supply ) 35.6 mcb fixing channel ( only supply ) 35.6.1 mcb fixing channel ( only labour ) 35.6.2 mcb fixing channel ( composite ) 35.7 connector fixing channel ( cst channel ) ( only supply ) 35.7.1 connector fixing channel ( cst channel ) ( only labour ) 35.7.2 connector fixing channel ( cst channel ) ( composite ) 35.8 ht electrical tape ( strippex ) , 25 mm x .76 mm x 9.1 m , one roll, make stanvac ( only supply ) 35.9 supply / fixing of assorted accessories 35.9.1 6 amps, 3 pin multi plug connector ( only supply ) 35.9.2 6 amps, 3 pin multi plug connector ( only labour ) 35.9.3 6 amps, 3 pin multi plug connector ( composite ) 35.9.4 16 amps, multi plug connector ( only supply ) 35.9.5 16 amps, multi plug connector ( only labour ) 35.9.6 16 amps, multi plug connector ( composote ) 35.9.7 6a, supper adaptor pearl ( only supply ) 35.9.8 6a, supper adaptor pearl ( only labour ) 35.9.9 6a, supper adaptor pearl ( composite ) 35.9.10 1 way bed switch ( only supply ) 35.9.11 1 way bed switch ( only labour ) 35.9.12 1 way bed switch ( composite ) 35.9.13 adaptor ( only supply ) 35.9.14 adaptor ( only labour ) 35.9.15 adaptor ( composite ) 35.9.16 3 pin flexi cord 6 a, ( extension board ) ( only supply ) 35.9.17 16 a, flexi cord, ( extension board ) ( only supply ) 35.10.a supply / fixing of various gang boxes: 35.10.1 1 way ( only supply ) 35.10.2 1 way ( only labour ) 35.10.3 1 way ( composite ) 35.10.4 2 way ( only supply ) 35.10.5 2 way ( only labour ) 35.10.6 2 way ( composite ) 35.10.7 3 way ( only supply ) 35.10.8 3 way ( only labour ) 35.10.9 3 way ( composite ) 35.10.10 4 way ( only supply ) 35.10.11 4 way ( only labour ) 35.10.12 4 way ( composite ) 35.10.13 5 way ( only supply ) 35.10.14 5 way ( only labour ) 35.10.15 5 way ( composite ) 35.11 supply / fixing of various domestic gang boxes: 35.11.1 1 way ( only supply ) 35.11.2 1 way ( only labour ) 35.11.3 1 way ( composite ) 35.11.4 2 way ( only supply ) 35.11.5 2 way ( only labour ) 35.11.6 2 way ( composite ) 35.11.7 3 way ( only supply ) 35.11.8 3 way ( only labour ) 35.11.9 3 way ( composite ) 35.11.10 4 way ( only supply ) 35.11.11 4 way ( only labour ) 35.11.12 4 way ( composite ) 35.11.13 double domestic ( only supply ) 35.11.14 double domestic ( only labour ) 35.11.15 double domestic ( composite ) 35.11.16 water proof jb for mk switch ( to be used in icu ) ( only supply ) 35.11.17 water proof jb for mk switch ( to be used in icu ) ( only labour ) 35.11.18 water proof jb for mk switch ( to be used in icu ) ( composite ) 35.11.19 legrand make modular type door key switch with key fob ( only supply ) 35.11.20 legrand make modular type door key switch with key fob ( only labour ) 35.11.21 legrand make modular type door key switch with key fob ( composite ) 35.11.22 10a modular switch legrand ( only supply ) 35.11.23 10a modular switch legrand ( only labour ) 35.11.24 10a modular switch legrand ( composite ) 35.11.25 10a modular socket legrand ( only supply ) 35.11.26 10a modular socket legrand ( only labour ) 35.11.27 10a modular socket legrand ( composite ) 35.11.28 20a modular switch legrand ( only supply ) 35.11.29 20a modular switch legrand ( only labour ) 35.11.30 20a modular switch legrand ( composite ) 35.11.31 20a modular socket legrand ( only supply ) 35.11.32 20a modular socket legrand ( only labour ) 35.11.33 20a modular socket legrand ( composite ) 36.1 supplying & replacing the following spare of electrical motor starter controls etc. or whereever applicable with coil voltage 240 v / 440 v.all as per instructions and as directed by e i c, es. old items shall be returned to e i c, es as it is.air brake contactors 36.1.1 air brake contactor l & t make type ml1 or equivalent ( only supply ) 36.1.2 air brake contactor l & t make type ml1 or equivalent ( only labour ) 36.1.3 air brake contactor l & t make type ml1 or equivalent ( composite ) 36.1.4 ml 1.5 or equivalent ( only supply ) 36.1.5 ml 1.5 or equivalent ( only labour ) 36.1.6 ml 1.5 or equivalent ( composite ) 36.1.7 ml 2 or equivalent ( only supply ) 36.1.8 ml 2 or equivalent ( only labour ) 36.1.9 ml 2 or equivalent ( composite ) 36.1.10 ml 3 or equivalent ( only supply ) 36.1.11 ml 3 or equivalent ( only labour ) 36.1.12 ml 3 or equivalent ( composite ) 36.1.13 ml 4 or equivalent ( only supply ) 36.1.14 ml 4 or equivalent ( only labour ) 36.1.15 ml 4 or equivalent ( composite ) 36.1.16 ml 6 or equivalent ( only supply ) 36.1.17 ml 6 or equivalent ( only labour ) 36.1.18 ml 6 or equivalent ( composite ) 36.1.19 ml 10 or equivalent ( only supply ) 36.1.20 ml 10 or equivalent ( only labour ) 36.1.21 ml 10 or equivalent ( composite ) 36.1.22 ml 12 or equivalent ( only supply ) 36.1.23 ml 12 or equivalent ( only labour ) 36.1.24 ml 12 or equivalent ( composite ) 36.2 supply & replacement of following spare parts, kit for l & t or equivalent make power contactor. work is to be carried out as per instructions ans as per direction of e i c, es. old / remob ved items shall be returned to e i c, es as it is. 36.2.1 ml 1 or equivalent ( only supply ) 36.2.2 ml 1 or equivalent ( only labour ) 36.2.3 ml 1 or equivalent ( composite ) 36.2.4 ml 1.5 or equivalent ( only supply ) 36.2.5 ml 1.5 or equivalent ( only labour ) 36.2.6 ml 1.5 or equivalent ( composite ) 36.2.7 ml 2 or equivalent ( only supply ) 36.2.8 ml 2 or equivalent ( only labour ) 36.2.9 ml 2 or equivalent ( composite ) 36.2.10 ml 3 or equivalent ( only supply ) 36.2.11 ml 3 or equivalent ( only labour ) 36.2.12 ml 3 or equivalent ( composite ) 36.2.13 ml 4 or equivalent ( only supply ) 36.2.14 ml 4 or equivalent ( only labour ) 36.2.15 ml 4 or equivalent ( composite ) 36.2.16 ml 6 or equivalent ( only supply ) 36.2.17 ml 6 or equivalent ( only labour ) 36.2.18 ml 6 or equivalent ( composite ) 36.2.19 ml 10 or equivalent ( only supply ) 36.2.20 ml 10 or equivalent ( only labour ) 36.2.21 ml 10 or equivalent ( composite ) 36.2.22 ml 12 or equivalent ( only supply ) 36.2.23 ml 12 or equivalent ( only labour ) 36.2.24 ml 12 or equivalent ( composite ) 36.3 supply & fixing of hrc fuses as per instructions and as directed by e i c, es. old / removed item shall be returned to e i c, es. 36.3.1 1a to 6a ( only supply ) 36.3.2 1a to 6a ( only labour ) 36.3.3 1a to 6a ( composite ) 36.3.4 16a ( only supply ) 36.3.5 16a ( only labour ) 36.3.6 16a ( composite ) 36.3.7 32a ( only supply ) 36.3.8 32a ( only labour ) 36.3.9 32a ( composite ) 36.3.10 63a ( only supply ) 36.3.11 63a ( only labour ) 36.3.12 63a ( composite ) 36.3.13 100a ( only supply ) 36.3.14 100a ( only labour ) 36.3.15 100a ( composite ) 36.3.16 125a ( only supply ) 36.3.17 125a ( only labour ) 36.3.18 125a ( composite ) 36.3.19 160a ( only supply ) 36.3.20 160a ( only labour ) 36.3.21 160a ( composite ) 36.3.22 250a ( only supply ) 36.3.23 250a ( only labour ) 36.3.24 250a ( composite ) 36.3.25 315a ( only supply ) 36.3.26 315a ( only labour ) 36.3.27 315a ( composite ) 36.3.28 400a ( only supply ) 36.3.29 400a ( only labour ) 36.3.30 400a ( composite ) 36.3.31 630a ( only supply ) 36.3.32 630a ( only labour ) 36.3.33 630a ( composite ) 36.3.34 800 a ( only supply ) 36.3.35 800 a ( only labour ) 36.3.36 800 a ( composite ) 36.4 replacement of the following item make bakelite cut out complete fuse holder db mounted, all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.4.1 16 a ( only supply ) 36.4.2 16 a ( only labour ) 36.4.3 16 a ( composite ) 36.4.4 32 a ( only supply ) 36.4.5 32 a ( only labour ) 36.4.6 32 a ( composite ) 36.4.7 63 a ( only supply ) 36.4.8 63 a ( only labour ) 36.4.9 63 a ( composite ) 36.5 replacement of the kit kat fuse all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.5.1 1a delay fuse ( only supply ) 36.5.2 1.5 a delay fuse ( only supply ) 36.5.3 5 amps ( only supply ) 36.5.4 5 amps ( only labour ) 36.5.5 5 amps ( composite ) 36.5.6 10 amps ( only supply ) 36.5.7 10 amps ( only labour ) 36.5.8 10 amps ( composite ) 36.5.9 15 amps ( only supply ) 36.5.10 15 amps ( only labour ) 36.5.11 15 amps ( composite ) 36.6 replacement of the porcelain fuse ( base +top ) all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.6.1 5 amps ( only supply ) 36.6.2 5 amps ( only labour ) 36.6.3 5 amps ( composite ) 36.6.4 10 amps ( only supply ) 36.6.5 10 amps ( only labour ) 36.6.6 10 amps ( composite ) 36.6.7 25 amps ( only supply ) 36.6.8 25 amps ( only labour ) 36.6.9 25 amps ( composite ) 36.6.10 32 amps ( only supply ) 36.6.11 32 amps ( only labour ) 36.6.12 32 amps ( composite ) 36.7 replacement of the neutral link all as per instructions and as directed by e i c, es. old / removed items shall be returened to e i c, es. 36.7.1 16 a ( only supply ) 36.7.2 16 a ( only labour ) 36.7.3 16 a ( composite ) 36.7.4 32 a ( only supply ) 36.7.5 32 a ( only labour ) 36.7.6 32 a ( composite ) 36.7.7 63 a ( only supply ) 36.7.8 63 a ( only labour ) 36.7.9 63 a ( composite ) 36.8 replacement of elmex / connectwell connector block suitable for following cable sizes & reconnection of vided leads, all as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.8.1 1.5 sq. mm ( only supply ) 36.8.2 1.5 sq. mm ( only labour ) 36.8.3 1.5 sq. mm ( composite ) 36.8.4 2.5 sq. mm ( only supply ) 36.8.5 2.5 sq. mm ( only labour ) 36.8.6 2.5 sq. mm ( composite ) 36.8.7 4 sq. mm ( only supply ) 36.8.8 4 sq. mm ( only labour ) 36.8.9 4 sq. mm ( composite ) 36.8.10 6 sq. mm ( only supply ) 36.8.11 6 sq. mm ( only labour ) 36.8.12 6 sq. mm ( composite ) 36.8.13 10 sq. mm ( only supply ) 36.8.14 10 sq. mm ( only labour ) 36.8.15 10 sq. mm ( composite ) 36.8.16 16 sq. mm ( only supply ) 36.8.17 16 sq. mm ( only labour ) 36.8.18 16 sq. mm ( composite ) 36.8.19 25 sq. mm ( only supply ) 36.8.20 25 sq. mm ( only labour ) 36.8.21 25 sq. mm ( composite ) 36.8.22 35 sq. mm ( only supply ) 36.8.23 35 sq. mm ( only labour ) 36.8.24 35 sq. mm ( composite ) 36.8.25 50 sq. mm ( only supply ) 36.8.26 50 sq. mm ( only labour ) 36.8.27 50 sq. mm ( composite ) 36.8.28 70 sq. mm ( only supply ) 36.8.29 70 sq. mm ( only labour ) 36.8.30 70 sq. mm ( composite ) 36.8.31 95 sq. mm ( only supply ) 36.8.32 95 sq. mm ( only labour ) 36.8.33 95 sq. mm ( composite ) 36.8.34 120 sq. mm ( only supply ) 36.8.35 120 sq. mm ( only labour ) 36.8.36 120 sq. mm ( composite ) 36.8.37 ct shorting terminals ( only supply ) 36.8.38 ct shorting terminals ( only labour ) 36.8.39 ct shorting terminals ( composite ) 36.9 supply / replacement of terminal strips / blocks for varios types of motors etc as per instructions and as directed by e i c, es. old / removed items shall be returned to e i c, es as it is. 36.9.1 motors up to 10 hp ( only supply ) 36.9.2 motors up to 10 hp ( only labour ) 36.9.3 motors up to 10 hp ( composite ) 36.9.4 motors up to 20 hp ( only supply ) 36.9.5 motors up to 20 hp ( only labour ) 36.9.6 motors up to 20 hp ( composite ) 36.9.7 motors up to 30 hp ( only supply ) 36.9.8 motors up to 30 hp ( only labour ) 36.9.9 motors up to 30 hp ( composite ) 36.9.10 motors up to 40 hp ( only supply ) 36.9.11 motors up to 40 hp ( only labour ) 36.9.12 motors up to 40 hp ( composite ) 36.9.13 motors up to 50 hp ( only supply ) 36.9.14 motors up to 50 hp ( only labour ) 36.9.15 motors up to 50 hp ( composite ) 36.9.16 motors up to 60 hp ( only supply ) 36.9.17 motors up to 60 hp ( only labour ) 36.9.18 motors up to 60 hp ( composite ) 37.1 .ms sheet for boxes etc ms sheet for 16 swg to be used for fabrication of boxes, panels, cable and boxes etc. including cutting, bending, drilling, welding, riveting etc & painting with red oxide lead paint & two coats of enamel paint all as per instructions and as directed by e i c, es. 37.1.1 as per item no 37.1 for 14 swg ( only supply ) 37.1.2 as per item no 37.1 for 14 swg ( only labour ) 37.1.3 as per item no 37.1 for 14 swg ( composite ) 37.1.4 as per item no 37.1 for but for 16 swg ( only supply ) 37.1.5 as per item no 37.1 for but for 16 swg ( only labour ) 37.1.6 sas per item no 37.1 for but for 16 swg ( composite ) 37.1.7 as per item no 37.1 for but for 18 swg ( only supply ) 37.1.8 as per item no 37.1 for but for 18 swg ( only labour ) 37.1.9 as per item no 37.1 for but for 18 swg ( composite ) 37.2 supply, fabrication & installation of ms angle / strip / plate / rod / channel etc. as per given design duly painted with 2 coats of red oxide & 2 coats of enamel paint of approved shade all as per the instruction of eic. ( composite ) 37.3 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.3.1 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.3.2 hylam sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.4 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only supply ) 37.4.1 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( only labour ) 37.4.2 bakelite sheet 3 mm thick to be used for covering ms sheet box including cutting, drilling, fixing with nut bolts / screws, cup washers etc. complete as required & to satisfaction of in charge with making necessary grove / cutting for fixing electrical accessories. ( composite ) 37.5 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only supply ) 37.5.1 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( only labour ) 37.5.2 supplying & erecting / fixing 6 mm thick marine plywood of good quality with necessary material ( composite ) 38.1 timers for starters / preventers supply, fixing & testing of on delay timer 0 to 60 sec. ( only supply ) 38.2 supply, fixing & testing of on delay timer 0 to 60 sec. ( only labour ) 38.3 supply, fixing & testing of on delay timer 0 to 60 sec. ( composite ) 38.4 supply, fixing & testing of off delay timer ( only supply ) 38.5 supply, fixing & testing of off delay timer ( only labour ) 38.6 supply, fixing & testing of off delay timer ( composite ) 38.7 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( only supply ) 38.8 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 38.9 supply, fixing & testing of fm / 1 quartz 24 hrs set electronic timer ( composite ) 39 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.1 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( only labour ) 39.2 supply, fixing & testing of star delta starter timer [ 0 60 sec. ] [ 1 no + 1 nc ( composite ) 39.3 single phase preventer type mpr1 ( only supply ) 39.4 single phase preventer type mpr1 ( only labour ) 39.5 single phase preventer type mpr1 ( composite ) 39.6 supply, fixing & testing of 0 24 hrs set digital timer ( only supply ) 39.7 supply, fixing & testing of 0 24 hrs set digital timer ( only labour ) 39.8 supply, fixing & testing of 0 24 hrs set digital timer ( composit ) 40.1 supply, installation & testing of app type capacitors / apfc relays, 440 v, 50 hz, all as per instructions ans as directed by e i c, es old / removed items shall be returned to e i c, es as it is. 25 kvar ( only supply ) 40.2 25 kvar ( only labour ) 40.3 25 kvar ( composite ) 40.4 50 kvar ( only supply ) 40.5 50 kvar ( only labour ) 40.6 50 kvar ( composite ) 40.7 100 kvar ( only supply ) 40.8 100 kvar ( only labour ) 40.9 100 kvar ( composite ) 40.10.a supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only supply ) 40.11 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( only labour ) 40.12 supply, installation & testing of apfc relay suitable for 8 equal steps, 440 v, 50 hz, ac. ( composite ) 40.13 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only supply ) 40.14 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( only labour ) 40.15 supply, installation & testing of kvar meter. 144 x 144 with transducer. ( composite ) 41.1 fittings & fixtures supply / replacement, installation, testing & commissioning of following various fixtures & fittings complete with fluorescent tube / incandescent lamp / pl s lamp or any other suitale lamp etc. on surface of slab / beam / wall by means of brackets made out of 25 x 3 mm strip & 2 nos. of 6 mm anchor fastener / suspended from slab / beam by means of 19 mm dia. conduit pipe, ball & socket arrangement flexible 2 core 40 / 30 size cable / wire connection etc.or by means of suitable fixing arrangement, complete in all respect & as per instruction of engg. in charge & with prior approval by presenting sample fitting. make:philips / crompton / ge / wipro / orient or equivalent. in case of replacement old / removed items shall be reuturned to e i c, es as it is. 1 x 40 w rail ( box ) type fluorescent fitting ( only supply ) 41.2 1 x 40 w rail ( box ) type fluorescent fitting ( only labour ) 41.3 1 x 40 w rail ( box ) type fluorescent fitting ( composite ) 41.4 2 x 40 w rail type fluorescent ( only supply ) 41.5 2 x 40 w rail type fluorescent ( only labour ) 41.6 2 x 40 w rail type fluorescent ( composite ) 41.7 2 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.8 2 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.9 2 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.10.a 1 x 40 w decorative mirror optic fluorescent fitting ( only supply ) 41.11 1 x 40 w decorative mirror optic fluorescent fitting ( only labour ) 41.12.a 1 x 40 w decorative mirror optic fluorescent fitting ( composite ) 41.13 2 x 40 w industrial type fluorescent fitting ( only supply ) 41.14 2 x 40 w industrial type fluorescent fitting ( only labour ) 41.15 2 x 40 w industrial type fluorescent fitting ( composite ) 41.16 2 x 9 w pl s decorative recess type fitting. ( only supply ) 41.17.a 2 x 9 w pl s decorative recess type fitting. ( only labour ) 41.18 2 x 9 w pl s decorative recess type fitting. ( composite ) 41.19 2 x 11 w decorative surface type fitting ( only supply ) 41.20.a 2 x 11 w decorative surface type fitting ( only labour ) 41.21 2 x 11 w decorative surface type fitting ( composite ) 41.22 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only supply ) 41.23 1 x 40 w decorative mirror optic fluorescent fitting surface type ( only labour ) 41.24 1 x 40 w decorative mirror optic fluorescent fitting surface type ( composite ) 41.25 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only supply ) 41.26 2 x 40 w decorative mirror optic fluoresce fitting surface type ( only labour ) 41.27 2 x 40 w decorative mirror optic fluoresce fitting surface type ( composite ) 41.28 bulkhead fitting suitable for pl – s 9 w lamp ( only supply ) 41.29 bulkhead fitting suitable for pl – s 9 w lamp ( only labour ) 41.30.a bulkhead fitting suitable for pl – s 9 w lamp ( composite ) 41.31 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only supply ) 41.32 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( only labour ) 41.33 1 x 30 w germicidal fluorescent box type ss fitting with ulitrea violet tube light ( composite ) 41.34 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.35 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.36 1 x 30 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.37 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only supply ) 41.38 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( only labour ) 41.39 1 x 20 / 18 w germicidal fluorescent box type fitting with ulitrea violet tube light ( composite ) 41.40.a 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only supply ) 41.41 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( only labour ) 41.42 100 w decorative fixtures for the dark room ( gemini global cat no. 3083 ) ( composite ) 41.43 decorative incandescent fixtures for red indication lamp ( only supply ) 41.44 decorative incandescent fixtures for red indication lamp ( only labour ) 41.45 decorative incandescent fixtures for red indication lamp ( composite ) 41.46 decorative incandescent fixtures with 75 w comptalux lamp ( only supply ) 41.47 decorative incandescent fixtures with 75 w comptalux lamp ( only labour ) 41.48 decorative incandescent fixtures with 75 w comptalux lamp ( composite ) 41.49 decorative incandescent fixtures for lecture hall [ 100w ] ( ( only supply ) 41.50.a decorative incandescent fixtures for lecture hall [ 100w ] ( ( only labour ) 41.51 decorative incandescent fixtures for lecture hall [ 100w ] ( ( composite ) 41.52 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only supply ) 41.53 1 x 9 w decorative wall mounted fixtures with electronic ballast ( only labour ) 41.54 1 x 9 w decorative wall mounted fixtures with electronic ballast ( composite ) 41.55 2 x 9 w decorative fixtures for ( entrance canopy ) ( only supply ) 41.56 2 x 9 w decorative fixtures for ( entrance canopy ) ( only labour ) 41.57 2 x 9 w decorative fixtures for ( entrance canopy ) ( composite ) 41.58 2 x 25 w exit light fixture ( only supply ) 41.59 2 x 25 w exit light fixture ( only labour ) 41.60.a 2 x 25 w exit light fixture ( composite ) 41.61 2 x 18 w fluorescent industrial fitting for fume hood ( only supply ) 41.62 2 x 18 w fluorescent industrial fitting for fume hood ( only labour ) 41.63 2 x 18 w fluorescent industrial fitting for fume hood ( composite ) 41.64 1 x 9 w decorative surface fitting for wash basin mirror ( only supply ) 41.65 1 x 9 w decorative surface fitting for wash basin mirror ( only labour ) 41.66 1 x 9 w decorative surface fitting for wash basin mirror ( composite ) 41.67 night lamp fixture 15 w ( only supply ) 41.68 night lamp fixture 15 w ( only labour ) 41.69 night lamp fixture 15 w ( composite ) 41.70.a halogen lamp fitting. 41.70.1 suitable for 500 w ( only supply ) 41.70.2 suitable for 500 w ( only labour ) 41.70.3 suitable for 500 w ( composite ) 41.70.4 suitable for 1000 w ( only supply ) 41.70.5 suitable for 1000 w ( only labour ) 41.70.6 suitable for 1000 w ( composite ) 41.71 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only supply ) 41.72 decorative incandescent fixture with 60 w / 75 w reflector lamp ( only labour ) 41.73 decorative incandescent fixture with 60 w / 75 w reflector lamp ( composite ) 41.74 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only supply ) 41.75 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( only labour ) 41.76 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , surface type ( composite ) 41.77 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only supply ) 41.78 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( only labour ) 41.79 incandescent lamp fitting with 60 w / 100 w lamp for radiological lab , recess type ( composite ) 41.80.a recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only supply ) 41.81 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( only labour ) 41.82 recessed adjustable down lighter with separate t / f 1 x 12 v, 50 w halogen ( composite ) 41.83 floor washer ( only supply ) 41.84 floor washer ( only labour ) 41.85 floor washer ( composite ) 41.86 turbolite with 6 cell reflector ( only supply ) 41.87 turbolite with 6 cell reflector ( only labour ) 41.88 turbolite with 6 cell reflector ( composite ) 41.89 solaris down lighter ( only supply ) 41.90.a solaris down lighter ( only labour ) 41.91 solaris down lighter ( composite ) 41.92 moisture proof halogen recessed fixture ( only supply ) 41.93 moisture proof halogen recessed fixture ( only labour ) 41.94 moisture proof halogen recessed fixture ( composite ) 41.95 gemini baflux max 2x 18 w plc lamp ( only supply ) 41.96 gemini baflux max 2x 18 w plc lamp ( only labour ) 41.97 gemini baflux max 2x 18 w plc lamp ( composite ) 41.98 rivia mini with 1 plc 10w ( only supply ) 41.99 rivia mini with 1 plc 10w ( only labour ) 41.100.a rivia mini with 1 plc 10w ( composite ) 41.101 emergency tube light fixture suitable to fix 9w pl lamp, ( only supply ) 41.102 emergency tube light fixture suitable to fix 9w pl lamp, ( only labour ) 41.103 emergency tube light fixture suitable to fix 9w pl lamp, ( composite ) 41.104 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only supply ) 41.105 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( only labour ) 41.106 reputed make tbs 300 / 418 m1 hpf , 4 x ‘tl’d 18 w / tl 20 w recessed mounting mirror optic fluorescent lighting fixture. ( composite ) 41.107 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only supply ) 41.108 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( only labour ) 41.109 reputed make fbs 285 / 218 2 x pl l 18 w recessed mirror optic pl fitting or equivalent ( composite ) 41.110.a dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only supply ) 41.111 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( only labour ) 41.112 dn 622 ( white ) recessed accent lighting with matt finished with reflector, reputed make suitable or 1 x 100 w glass lamp or equivalent ( composite ) 41.113 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only supply ) 41.114 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( only labour ) 41.115 fdn 622 / 01 ( white ) recessed accent lighting with matt finished with reflector inclusive of gear box, reputed make , suitable for 1 x pl s 9w, or equivalent ( composite ) 41.116 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.117 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.118 fbh 145 / 113 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 1 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.119 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only supply ) 41.120.a fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( only labour ) 41.121 fbh 145 / 213 low depth recessed low glare down lighter inclusive of enclosed control gear box , matt finish reflector including glass attachment, suitable for 2 x pl c 10 / 13 w , reputed make or equivalent ( composite ) 41.122 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only supply ) 41.123 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( only labour ) 41.124 dn 652, recessed adjustable accent lighting luminary inclusive of separate transformer with lamp or equivalent ( composite ) 41.125 2 x 36w pll fixture ( only supply ) 41.126 2 x 36w pll fixture ( only labour ) 41.127 2 x 36w pll fixture ( composite ) 41.128 25w, plc, lighting fixture ( only supply ) 41.129 25w, plc, lighting fixture ( only labour ) 41.130.a 25w, plc, lighting fixture ( composite ) 41.131 1x28w, energy efficient box type fitting ( only supply ) 41.132 1x28w, energy efficient box type fitting ( only labour ) 41.133 1x28w, energy efficient box type fitting ( composite ) 41.134 25w, plc lighting fixture ( only supply ) 41.135 25w, plc lighting fixture ( only labour ) 41.136 25w, plc lighting fixture ( composite ) 41.137 led light fixtures 6w recessed mounted led lighting fixture ( only supply ) 41.138 6w recessed mounted led lighting fixture ( only labour ) 41.139 6w recessed mounted led lighting fixture ( composite ) 41.140.a 9w recessed mounted led lighting fixture ( only supply ) 41.141 9w recessed mounted led lighting fixture ( only labour ) 41.142 9w recessed mounted led lighting fixture ( composite ) 41.143 12w recessed mounted led lighting fixture ( only supply ) 41.144 12w recessed mounted led lighting fixture ( only labour ) 41.145 12w recessed mounted led lighting fixture ( composite ) 41.146 15w recessed mounted led lighting fixture ( only supply ) 41.147 15w recessed mounted led lighting fixture ( only labour ) 41.148 15w recessed mounted led lighting fixture ( composite ) 41.149 18w recessed mounted led lighting fixture ( only supply ) 41.150.a 18w recessed mounted led lighting fixture ( only labour ) 41.151 18w recessed mounted led lighting fixture ( composite ) 41.152 24w recessed mounted led lighting fixture ( only supply ) 41.153 24w recessed mounted led lighting fixture ( only labour ) 41.154 24w recessed mounted led lighting fixture ( composite ) 41.155 3w recessed led type halogen lighting fixture ( only supply ) 41.156 3w recessed led type halogen lighting fixture ( only labour ) 41.157 3w recessed led type halogen lighting fixture ( composite ) 41.158 6w recessed led type halogen lighting fixture ( only supply ) 41.159 6w recessed led type halogen lighting fixture ( only labour ) 41.160.a 6w recessed led type halogen lighting fixture ( composite ) 41.161 9w recessed led type halogen lighting fixture ( only supply ) 41.162 9w recessed led type halogen lighting fixture ( only labour ) 41.163 9w recessed led type halogen lighting fixture ( composite ) 41.164 36w, 2x2 size recessed led lighting fixture ( only supply ) 41.165 36w, 2x2 size recessed led lighting fixture ( only labour ) 41.166 36w, 2x2 size recessed led lighting fixture ( composite ) 41.167 42w, 2x2 size recessed led lighting fixture ( only supply ) 41.168 42w, 2x2 size recessed led lighting fixture ( only labour ) 41.169 42w, 2x2 size recessed led lighting fixture ( composite ) 41.170 32w, 4 long fully diffused recessed led lighting fixture ( only supply ) 41.171 32w, 4 long fully diffused recessed led lighting fixture ( only labour ) 41.172 32w, 4 long fully diffused recessed led lighting fixture ( composite ) 41.173 6w surface mounted led lighting fixture ( only supply ) 41.174 6w surface mounted led lighting fixture ( only labour ) 41.175 6w surface mounted led lighting fixture ( composite ) 41.176 9w surface mounted led lighting fixture ( only supply ) 41.177 9w surface mounted led lighting fixture ( only labour ) 41.178 9w surface mounted led lighting fixture ( composite ) 41.179 12w surface mounted led lighting fixture ( only supply ) 41.180 12w surface mounted led lighting fixture ( only labour ) 41.181 12w surface mounted led lighting fixture ( composite ) 41.182 15w surface mounted led lighting fixture ( only supply ) 41.183 15w surface mounted led lighting fixture ( only labour ) 41.184 15w surface mounted led lighting fixture ( composite ) 41.185 18w surface mounted led lighting fixture ( only supply ) 41.186 18w surface mounted led lighting fixture ( only labour ) 41.187 18w surface mounted led lighting fixture ( composite ) 41.188 24w surface type led lighting fixture ( only supply ) 41.189 24w surface type led lighting fixture ( only labour ) 41.190 24w surface type led lighting fixture ( composite ) 41.191 22w, 4 long surface type led lighting fixture ( only supply ) 41.192 22w, 4 long surface type led lighting fixture ( only labour ) 41.193 22w, 4 long surface type led lighting fixture ( composite ) 41.194 8w, 2 long surface type led lighting fixture ( only supply ) 41.195 8w, 2 long surface type led lighting fixture ( only labour ) 41.196 8w, 2 long surface type led lighting fixture ( composite ) 41.197 32w, 4 long fully diffused surface led lighting fixture ( only supply ) 41.198 32w, 4 long fully diffused surface led lighting fixture ( only labour ) 41.199 32w, 4 long fully diffused surface led lighting fixture ( composite ) 41.200 22w, 4 long led tube ( only supply ) with one year warranty 41.201 22w, 4 long led tube ( only labour ) 41.202 22w, 4 long led tube ( only composite ) 42 providing, fixing & commissioning of ceiling fan white / brown colour as per requirement including down rod, double ball baring etc all as per instructions and as directed by e i c, es. in case of replacement old / removed item shall be returned to e i c, es as it is. 42.1 size 1400 mm sweep ( only supply ) 42.2 size 1400 mm sweep ( only labour ) 42.3 size 1400 mm sweep ( composite ) 42.4 size 1200 mm sweep ( only supply ) 42.5 size 1200 mm sweep ( only labour ) 42.6 size 1200 mm sweep ( composite ) 42.7 size 900 mm sweep ( only supply ) 42.8 size 900 mm sweep ( only labour ) 42.9 size 900 mm sweep ( composite ) 42.10.a same as per item no 42 but for wall mounted fan 42.10.1 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only supply ) 42.10.2 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( only labour ) 42.10.3 providing 1 phase decorative type 4 speed wall mounted fan, roller button, having swap facility, ( composite ) 42.11 same as per item no 42 but for pedestal mounted fan 42.11.1 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.2 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.3 providing 1 phase decorative type pedestal fan, roller button, having swap facility, ( composite ) 42.11.4 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only supply ) 42.11.5 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( only labour ) 42.11.6 providing 1 phase heavy dutye type pedestal fan, roller button, having swap facility, ( composite ) 43 providing & erecting 1 phase or exhaust fan metal body with ms frame & gravity louvers, 1400 rpm, 230 v, 50 hz, all as per instructions and as directed by e i c, es. in case of replacement old / removed items shall be returned to e i c, es. 43.1.a 150 mm ( only supply ) 43.2 150 mm ( only labour ) 43.3 150 mm ( composite ) 43.4 200 mm ( only supply ) 43.5 200 mm ( only labour ) 43.6 200 mm ( composite ) 43.7 225 mm ( only supply ) 43.8 225 mm ( only labour ) 43.9 225 mm ( composite ) 43.10 300 mm ( only supply ) 43.11 300 mm ( only labour ) 43.12 300 mm ( composite ) 43.13 375 mm ( only supply ) 43.14 375 mm ( only labour ) 43.15 375 mm ( composite ) 43.16 450 mm ( only supply ) 43.17 450 mm ( only labour ) 43.18 450 mm ( composite ) street lighting supply / replacement, testing & commissioning of external terminal box of size 200 x 250 x 150 mm made of 4 mm thick cast iron / pvc, neatly painted complete with front operable door with allen key locking arrangement, arrangement for gland entry, water proof gasket, 4 nos. of 8 mm dia. 40 mm long brass terminals on 150 x 30 x 10 mm bakelite strip, 16 a hrc fuse base & carrier with 6 a hrc fuse / 16a sp mcb, 16 a neutral link, nipple or sleeve of external dia. 38 mm which can be inserted in 38 mm dia. gi pipe, all as directed by o i c, es. equvilent arrangement can be done only after prior approval for make as well as other releted fixing / control gear arrangement. in case of replacement old / removed item shall be returned to e i c, es. led street light fitting of following ratings having pressure die cast aluminimum housing with coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint , suitable to following features. luminaires suitable with base plate and fitted on a existing site pole. in built electronic led driver, high transmisivity diffuser>85%, ip 65 / 67 high efficacy, provide uniform low glare lighting , cri 70, warm white operating temperature: 40 to +60 celsius degree operatable voltage 220 240 v, 50 hz, pf>0.9, 44.1.1 70 / 85w cfl lamp fitting ( only supply ) 44.1.2 70 / 85w cfl lamp fitting ( only labour ) 44.1.3 70 / 85w cfl lamp fitting ( composite ) 44.1.4 9 / 11w, 12v, 75 ah solar stree light fitting ( only supply ) 44.1.5 9 / 11w, 12v, 75 ah solar stree light fitting ( only labour ) 44.1.6 9 / 11w, 12v, 75 ah solar stree light fitting ( composite ) 44.1.7 led street lights 20w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.8 20w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.9 20w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.10 25w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.11 25w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.12 25w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.13 35w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.14 35w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.15 35w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.16 60w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.17 60w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.18 60w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.19 70w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.20 70w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.21 70w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.22 90w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.23 90w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.24 90w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.25 120w, led street light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.26 120w, led street light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.27 120w, led street light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.28 20w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.29 20w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.30 20w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.31 30w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.32 30w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.33 30w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.34 50w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.35 50w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.36 50w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.37 80w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.38 80w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.39 80w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.40 100w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.41 100w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.42 100w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.43 120w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.44 120w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.45 120w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.46 150w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.47 150w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.48 150w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.49 200w, led flood light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.50 200w, led flood light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.51 200w, led flood light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.52 30w, led dom light fitting, ip 65 / 67 outdoor type ( only supply ) 44.1.53 30w, led dom light fitting, ip 65 / 67 outdoor type ( only labour ) 44.1.54 30w, led dom light fitting, ip 65 / 67 outdoor type ( composite ) 44.1.55 led street light drivers20w, led street light driver ( only supply ) 44.1.56 20w, led street light driver ( only labour ) 44.1.57 20w, led street light driver ( composite ) 44.1.58 25w, led street light driver ( only supply ) 44.1.59 25w, led street light driver ( only labour ) 44.1.60 25w, led street light driver ( composite ) 44.1.61 30 / 40w, led street light driver ( only supply ) 44.1.62 30 / 40w, led street light driver ( only labour ) 44.1.63 30 / 40w, led street light driver ( composite ) 44.1.64 60w, led street light driver ( only supply ) 44.1.65 60w, led street light driver ( only labour ) 44.1.66 60w, led street light driver ( composite ) 44.1.67 70w, led street light driver ( only supply ) 44.1.68 70w, led street light driver ( only labour ) 44.1.69 70w, led street light driver ( composite ) 44.1.70 90w, led street light driver ( only supply ) 44.1.71 90w, led street light driver ( only labour ) 44.1.72 90w, led street light driver ( composite ) 44.1.73 120w, led street light driver ( only supply ) 44.1.74 120w, led street light driver ( only labour ) 44.1.75 120w, led street light driver ( composite ) 44.1.76 150w, led street light driver ( only supply ) 44.1.77 150w, led street light driver ( only labour ) 44.1.78 150w, led street light driver ( composite ) 44.1.79 200w, led street light driver ( only supply ) 44.1.80 200w, led street light driver ( only labour ) 44.1.81 200w, led street light driver ( composite ) 44.2 street light pole erection 44.2.1 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 44.2.2 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 44.2.3 7 mtr. hot dip galvanised octagonal street light pole with 1.5m long single arm bracket, suitable for 44 m / sec wind speed with suitable foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable to 4cx16 sqmm size ( composite ) . 44.2.4 same as item no. 44.3.3 but with double arm brackets ( only supply ) . 44.2.5 same as item no. 44.3.3 but with double arm brackets ( only labour ) . 44.2.6 same as item no. 44.3.3 but with double arm brackets ( composite ) . 44.2.7 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 7 mtr. hot dip galvanised octagonal street light pole with hexagonal bracket suitable to mount integral flood light fixture & 1.5m double arm bracket suitable to mount two nos. of street light fixture. suitable for 47 m / sec wind speed. ( fixtures can be mounted on the hexagonal bracket on six sides of the bracket but at max only 3 no. of integral flood lights can be mounted at a time. ) .with suitable foundation bolts, bakelite with 2 nos. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only supply ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( only labour ) . 3 mtr. hot dip galvanised octagonal post top type pole having spigot on top of pole, suitable for 44 m / sec wind speed with foundation bolts, bakelite with 1 no. 6a sp mcb and stud type terminal block / connector box of approved make suitable for terminating cable up to 4cx16 sqmm size ( composite ) . casting of new foundation for 7 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . casting of new foundation for 3 mtr. poles of above type inlcuding excavation of pole pit. the concrete mix for rcc foundation of octagonal pole shall be m20. the scope shall also include grouting of foundation bolts including curing & provision of dwc hdpe pipe for passage the cable and finishing the surface ( composite ) . lamp holders 44.4 lamp holders 44.4.1 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only supply ) 44.4.2 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( only labour ) 44.4.3 lamp holders for lamp ( any type ) inclusive of halogen holder assembly. ( composite ) 44.6.25 supply & fixing of 70w cfl lamp reputed make ( only supply ) 44.6.26 supply & fixing of 70w cfl lamp reputed make ( only labour ) 44.6.27 supply & fixing of 70w cfl lamp reputed make ( composite ) 44.6.28 supply & fixing of 65w cfl lamp reputed make ( only supply ) 44.6.29 supply & fixing of 65w cfl lamp reputed make ( only labour ) 44.6.30 supply & fixing of 65w cfl lamp reputed make ( composite ) 44.6.31 supply & fixing of 85w cfl lamp reputed make ( only supply ) 44.6.32 supply & fixing of 85w cfl lamp reputed make ( only labour ) 44.6.33 supply & fixing of 85w cfl lamp reputed make ( composite ) 44.6.34 supply & fixing of 35w cfl lamp reputed make ( only supply ) 44.6.35 supply & fixing of 35w cfl lamp reputed make ( only labour ) 44.6.36 supply & fixing of 35w cfl lamp reputed make ( composite ) 45.1 telephone system all general guidelines will be as per any kind of point wiring. telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only supply ) 45.2 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( only labour ) 45.3 telephone point wiring with 2 pair 0.5 mm guage unarmored wire laid through rigid pvc pipe ( composite ) 45.4 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.5 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.6 telephone point wiring with 2 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.7 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.8 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.9 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.10.a telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.11 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.12 telephone point wiring with 5 pair 0.5 mm guage unarmored wire should be drawn through pvc casing capping. ( composite ) 45.13 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only supply ) 45.14 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( only labour ) 45.15 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc casing capping. ( composite ) 45.16 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only supply ) 45.17 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( only labour ) 45.18 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through pvc rigid pipe. ( composite ) 45.19 telephone point wiring with 1 pair 0.5 mm gauge unarmored wire should be drawn through provided pvc rigid pipe / casing capping. 45.19.1 1 pair, 0.5 mm gauge ( only supply ) 45.19.2 1 pair, 0.5 mm gauge ( only labour ) 45.19.3 1 pair, 0.5 mm gauge ( composite ) 45.19.4 2 pair, 0.5 mm gauge ( only supply ) 45.19.5 2 pair, 0.5 mm gauge ( only labour ) 45.19.6 2 pair, 0.5 mm gauge ( composite ) 45.19.7 5 pair, 0.5 mm guage ( only supply ) 45.19.8 5 pair, 0.5 mm guage ( only labour ) 45.19.9 5 pair, 0.5 mm guage ( composite ) 45.19.10 providing & installation of analogue telephone instrument 45.19.11 providing testing cord for crone block ( only supply ) 45.19.12 providing crone tool ( only supply ) 45.19.13 replacement of cord for tele. instrument, with rj 11 jack at both ends. ( only supply ) 45.19.14 servicing / repair of telephone instrument ( composite ) 45.19.15 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( only supply ) 45.19.16 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( labour ) 45.19.17 supply & laying of cat 6 cable through provided casing capping, pvc conduit all as directed by o i c, es ( composite ) 45.19.18 providing & installation of cordless telephone instrument 45.19.19 providing & installation of caller id telephone instrument 45.19.23 supply of camera equivalent 1.3mp / 2mp ip ir dome camera 45.19.24 supply of camera ( 2mp ) ip ir bullet camera 45.19.27 camera turbo hd720p or equivalent , indoor ir turret 1.0 megapixel analogue camera 45.19.28 supply of crimping tool 3 in 1 modular crimping tool, rj45, rj11 cat5e / cat6 lan cutter with cable cutter 45.19.29 sitc of 8 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.30 sitc of 16 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.31 sitc of 24 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24 x 10 / 100 / 1000 poe base t ports, 2 fixed sfp ( 1g ) with internal power supply ( 192w poe budget ) . 45.19.32 supply of 8 port normal switch or equivalent 45.19.33 supply of cat 6 patch cord 01 mtr 45.19.34 supply of cat 6 patch cord 03 mtr 46.1 battery system supply, installation, testing & commissioning of 2 volt batteries suitable 150 ah lead acid battery set and buy back of old battery ( only supply ) 46.2 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.3 supply, installation, testing & commissioning of 2 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.4 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only supply ) 46.5 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( only labour ) 46.6 supply, installation, testing & commissioning of 12 volt batteries suitable to 150 ah lead battery set and buy back of old battery. ( composite ) 46.7 supply, installation, testing & commissioning of 12 volt smf batteries . ( only supply ) 46.8 supply, installation, testing & commissioning of 12 volt smf batteries . ( only labour ) 46.9 supply, installation, testing & commissioning of 12 volt smf batteries . ( composite ) 46.10.a supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( only supply ) 46.11 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups.. ( only labour ) 46.12 supply, installation, testing & commissioning of 12 volt, 7ah smf batteries for ups. ( composite ) 46.13 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( supply ) 46.14 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( labour ) 46.15 supply, installation, testing & commissioning of 65 ah make maintenance free sealed batteries having 2 cells, each cell of 12 v to give max. voltage of 24 v for fire alarm system ( composite ) 46.16 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.17 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set and buy back of old battery ( only 46.18 supply, installation, testing & commissioning of 180ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg setand buy back of old battery ( composite ) 46.19 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only supply ) 46.20 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( only labour ) 46.21 supply, installation, testing & commissioning of 100 ah pulse lite batteries having give voltage of 12 v for dg set and buy back of old battery ( composite ) 46.22 distilled water for batteries ( lt. ) ( only supply ) 46.23 battery solution ( litre ) ( only supply ) 46.24 petroleum jelly ( kg ) ( only supply ) 46.25 castrol make ap 3 ball bearing grease ( only supply ) 46.26 battery cell tester, 2 v dc ( only supply ) 46.27 battery for emergency tube light ( only supply ) 46.28 hydrometer for battery solution checking ( only supply ) 46.29 rechargeable battery, 9 v ( for mike etc ) ( only supply ) 46.30.a rechargeable battery, 1.5 v ( only supply ) 46.31 pencil cell for a / c remote ( only supply ) 46.32 pencil cell for cordless bell ( only supply ) 46.33 pencil cell for urinal sensor, clock and general use ( only supply ) 46.34 charger for rechargeable batteries of best quality ( only supply ) 46.35 crc / ctc etc. for general maintenance ( only supply ) 46.36 steelgrip pvc insulation tape ( only supply ) 46.37 cutter machine blade ( only supply ) 46.38 supply of battery connetion cords / leads having lsuitable lug / clamp at the end etc with size of core / wire to connect the battery to ups / chargers etc. all as per instructions of ( only supply ) 46.39 supply of 12 v / 6 ah to 10ah range maintenance free / sealed rocket / / amara raja or other equivalent battery suitable for ups. prior approval for make & other specification is required. ( only supply ) 46.40.a supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only supply ) 46.41 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( only labour ) 46.42 supply, installation, testing & commissioning of 160ah make maintenance free lead acid batteries having give max. voltage of 12 v for dg set ( composite ) 46.43 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only supply ) 46.44 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( only labour ) 46.45 supply, installation, testing & commissioning of 100 ah vrla batteries having give max. voltage of 30 v for dg set and buy back of old battery ( composite ) 46.46 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only supply ) 46.47 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( only labour ) 46.48 supply, installation, testing & commissioning of 200ah amaron solar smf maintenance free lead acid batteries having give max. voltage of 12 v for solar panel ( composite ) 46.49 12volt 26ah maintenance free battery ( only supply ) 46.50.a 12volt 26ah maintenance free battery ( only labour ) 46.51 12volt 26ah maintenance free battery ( composite ) 46.52 12volt 42ah maintenance free battery ( only supply ) 46.53 12volt 42ah maintenance free battery ( only labour ) 46.54 12volt 42ah maintenance free battery ( composite ) 46.55 12volt 7ah maintenance free battery ( only supply ) 46.56 12volt 7ah maintenance free battery ( only labour ) 46.57 12volt 7ah maintenance free battery ( composite ) 46.58 12volt 12ah maintenance free battery ( only supply ) 46.59 12volt 12ah maintenance free battery ( only labour ) 46.60.a 12volt 12ah maintenance free battery ( composite ) 46.61 12volt 7.5ah maintenance free battery ( only supply ) 46.62 12volt 7.5ah maintenance free battery ( only labour ) 46.63 12volt 7.5ah maintenance free battery ( composite ) 47.00 the system of wiring shall consist of isi marked single core, pvc insulated, frls, 1100 volt grade, stranded, flexible copper conductor wires as per is : 694 amended upto date. 47.1 copper wires pvc , panel wires for interconnections. 1.5 sq. mm ( only supply ) 47.2 1.5 sq. mm ( only labour ) 47.3 1.5 sq. mm ( composite ) 47.4.a 2.5 sq. mm ( only supply ) 47.5 2.5 sq. mm ( only labour ) 47.6 2.5 sq. mm ( composite ) 47.7 4 sq. mm ( only supply ) 47.8 4 sq. mm ( only labour ) 47.9 4 sq. mm ( composite ) 47.10.a 6 sq. mm ( only supply ) 47.11 6 sq. mm ( only labour ) 47.12 6 sq. mm ( composite ) 47.13 10 sq. mm ( only supply ) 47.14 10 sq. mm ( only labour ) 47.15 10 sq. mm ( composite ) 47.16 16 sq. mm ( only supply ) 47.17 16 sq. mm ( only labour ) 47.18 16 sq. mm ( composite ) 47.19 25 sq. mm ( only supply ) 47.20.a 25 sq. mm ( only labour ) 47.21 25 sq. mm ( composite ) 47.22 35 sq. mm ( only supply ) 47.23 35 sq. mm ( only labour ) 47.24 35 sq. mm ( composite ) 47.25 50 sq. mm ( only supply ) 47.26 50 sq. mm ( only labour ) 47.27 50 sq. mm ( composite ) 47.28 70 sq. mm ( only supply ) 47.29 70 sq. mm ( only labour ) 47.30.a 70 sq. mm ( composite ) 47.30.1 95 sq. mm ( only supply ) 47.30.2 95 sq. mm ( only labour ) 47.30.3 95 sq. mm ( composite ) 47.31 connection wire for strip heaters along with porcelain balls over it etc. ( only supply ) 47.32 connection wire for strip heaters along with porcelain balls over it etc. ( only labour ) 47.33 connection wire for strip heaters along with porcelain balls over it etc. ( composite ) 47.34 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only supply ) ( one pack ) 47.35 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( only labuor ) 47.36 porcelain balls, small termination insulator etc for strip heaters / other any type of heater, all as directed by o i c, es ( composite ) 47.37 supply of various kinds / sizes of ms / gi bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.38 supply of various kinds / sizes of brass bolts / screws etc as per requirment etc all as instructed by e i c. ( only supply ) 47.39 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 6 mm 47.40 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 8 mm 47.41 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 10 mm 47.42 supply of various kinds / sizes of anchor fastners as per requirment etc all as instructed by e i c. ( only supply ) 12 mm 47.43 supply of verious size of drill bit 47.43.1 drill bit 3 / 16 ms 47.43.2 drill bit 3 / 16 concrete 47.43.3 drill bit 3 / 16 hammering 47.43.4 drill bit 1 / 8 ms 47.43.5 drill bit wooden set 47.43.6 drill bit concrete set 47.43.7 drill bit roraty hammer 4mm 47.43.8 drill bit roraty hammer 8 mm 47.43.9 drill bit roraty hammer 10 mm 47.43.10 drill bit roraty hammer 12 mm 47.43.11 drill machine rotary hammering type 47.43.12 drill pair set mm 47.43.13 drill pair set inches 47.43.14 mini hacksaw blade taparia make 47.43.15 hacksaw blade big size 47.43.16 mini hacksaw blade taparia make with frame 47.43.17 hacksaw blade big size with frame 47.43.18 hole saw cutter ms 16mm to 32mm 47.43.19 hole saw cutter ms 32mm to 75mm 47.43.20 hole saw cutter ms 75mm to 150mm 47.43.21 hole saw cutter ms 150mm to 300mm 47.43.22 pvc grip rawal plastic wall plug per pkt qty 200each 47.43.23 grinding wheel blade 48.1 oil filtration for 2 mva transformer 48.2 oil filtration for 4 / 4.5 mva transformer 48.3 supply & topping up of transformer oil 48.4 yearly servicing for air circuit breakers, 800a , 1000 a / 1250 a / 1600 a / 2000a / 2500a / 3200 a, 440 v, mpact, ge make , abb , sterling existing make , testing of breakers , all type test to be carry out , greasing activity, and complete servicing. 48.5 yearly servicing of circuit breakers 48.5.1 33 kv sf6 circuit breaker 48.5.2 11 kv sf6 circuit breaker 48.5.3 33kv vacuum circuit breaker 48.5.4 11kv vacuum circuit breaker 48.6 testing & calibration of all types of relays, existing makes relays in ht panel, lt panel 48.6.1 cdg 31 / cdag 51 48.6.2 vajh / vajc 48.6.3 vaa / vdg 48.6.4 vtt 48.6.5 vagm / cag / ccum / ycgf / cdv / mfvum 48.6.6 vax 48.6.7 apfc relay 48.6.8 tcs relay ber 2 / ber1 48.6.9 feeder protection relay bcf1 48.6.10 lock out relay 86 48.6.11 restricted earthfault relay 48.6.12 reverse power relay 48.6.13 earthfault relay 48.6.14 calibration of multimeter , clamp meter and megger, earth tester 48.7.1 annual servicing for transformers 2.0 mva 48.7.2 annual servicing for transformers 4.5 / 4.0 mva 48.8 cable fault detecting / fault finding for all sizes of cables. 48.9 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only supply ) 48.10.a supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( only labour ) 48.11 supply & installation of required size of teak wood bushes for sealing the existing hume pipe end wherever cable passes through with bituminous compound filling etc. all as per instructions of e i c. ( composite ) 48.12 testing & calibration of all types of energy meter 48.13 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only supply ) 48.14 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( only labour ) 48.15 supply and erecting approved make 33 kv fuse barrel with metal fittings. ( composite ) 48.16 providing pair of duly tested rubber hand glows suitable for working on 33kv supply ( only supply ) 48.17 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only supply ) 48.18 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( only labour ) 48.19 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 3mm thickness up to 33 kv ( composite ) 48.20.a supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only supply ) 48.21 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( only labour ) 48.22 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class b insulation confirming to is:15652 2006 having 2.5mm thickness up to 11 kv ( composite ) 48.23 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class a insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only supply ) 48.24 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( only labour ) 48.25 supplying and fixing of pvc synthetic elastomer electrically insulating mat with class c insulation confirming to is:15652 2006 having 2.0mm thickness up to 3.3 kv ( composite ) 48.26 supplying standerd first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage ( band aid ) adhesive tape for medicinal use, scissors, anti septic solution etc. ( only supply ) 48.27 testing and calibration of energy meters. 48.28 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only supply ) 48.29 supply and fixing of 33kv, epoxy type insulator for bus bar support ( only labour ) 48.30.a supply and fixing of 33kv, epoxy type insulator for bus bar support ( composite ) 49.1 pa address system male –female, all kinds of audio / video pins ( only supply ) ( pair ) 49.2 male–female, all kinds of audio / video pins ( only labour ) ( pair ) 49.3 male –female, all kinds of audio / video pins ( composite ) ( pair ) 49.4 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only supply ) 49.5 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( only labour ) 49.6 2 core multistranded double sheathed flexible cable for speaker & laying in casing capping ( composite ) 49.7 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only supply ) 49.8 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( only labour ) 49.9 2 core multistranded double sheathed flexible cable for speaker & laying in pvc 25mm conduit ( composite ) 49.16 cable tie nylon 6 / 6 – uv stabilized uv stabilized nylon 6 / 6 use in continuous or extended exposure to outdoor sunlight. weather resistant grade, enduring additional ultraviolet ( uv ) light. 49.16.1 as per 49.16 for 100 mm size pkt for 100 nos ( only supply ) 49.16.2 as per 49.16 for 200 mm size pkt for 100 nos ( only supply ) 49.16.3 as per 49.16 for 300 mm size pkt for 100 nos ( only supply ) 49.17 multimeter make mecho , 415volt ( only supply ) 49.18 clamp meter mecho make , 415volt ( only supply ) 49.19 hand driven insulation tester 500volt ( only supply ) 49.20.a meggar digital insulation tester 500volt ( only supply ) 49.21 supply, installation, laying and connection of g.i. perforated & ladder type cable tray with bends, tees, clamps and couplers for fixing of cable with suitable ms structure and anchor fastner for supporting and necessary hardware with necessary welding has to be done to complete the job from isa / ismc / plate. the job also includes to paint the structure with two coats of red oxide and two coats color of enamel paint as approved . all material shall be hot dip galvanised as per is ( 816 g / m2 ) and specifications. the structural steel supports for the trays are to be provided at every 1 mtrs. as per technical specifications. 49.21.1 600mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.2 300mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.3 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) ladder type tray 49.21.4 150mm ( w ) x 75mm ( h ) x 2mm ( thk ) perforated type tray 49.22 fiber accessories 49.22.1 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( only supply ) 49.22.2 supply of 12 core , 9 / 125 micron single mode os2 corrugated steel tape armoured loose tube gel filled fiber optical cable, all as per instruction of e i c and as directed by oic, es ( composite ) 49.22.3 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( only supply ) 49.22.4 supply of os2 fully loaded fiber tray liu, which includes adaptors , pigtails, splice protectors etc for the termination of 12 core single mode fiber cable. ( composite ) 49.22.5 supply of sm duplex type 03 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.6 supply of sm duplex type 10 mtr patch cord , om2 , lc lc, lc sc any combination as required ( only supply ) 49.22.7 supply of hdmi cable for monitor including end connectors 49.22.8 fiber core splicing charges per core composite work...

Directorate Of Municipal Administration - Maharashtra

37141987 tender for supplying required electrical materials and doing essential electrical work under municipal council hinganghat 2nd call. 1 supplying & erecting h.m.s. p.v.c. conduit 20 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 2 supplying & laying hms pvc conduit 20 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 3 supplying & erecting hms p.v.c. conduit 25 mm. dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 4 supplying & laying hms pvc conduit 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 5 supplying and erecting upvc reinforced flexible conduit 20 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 6 supplying and erecting upvc reinforced flexible conduit 25 mm in dia. conforming to i.s. with required number of couplings, pvc bushes, check nuts etc. complete. 7 supplying and erecting hms pvc conduit 20 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 8 supplying and erecting hms pvc conduit 25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 9 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 20 mm with accessories on wall / ceiling as per specification no: wg ma / con. 10 supplying and erecting pvc trunking ( pvc casing ncapping ) of size 25 mm with accessories on wall / ceiling as per specification no: wg ma / con. 11 supplying & erecting mains with 2x1.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 12 supplying & erecting mains with 2x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 13 supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wgma / bw 14 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 15 supplying & erecting mains with 2x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 16 supplying & erecting mains with 3x2.5 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 17 supplying & erecting mains with 3x4 sq.mm fr copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 18 supplying & erecting mains with 3x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 19 supplying & erecting mains with 3x10 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 20 supplying & erecting mains with 4x16 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 21 supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 22 supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6a. erected on filledpolypropylene board or polished double wooden block / pvcjunction box. 23 supplying and erecting isi mark modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. 24 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 25 supplying and erecting isi mark modular type switch 16 / 20 a with indicator, duly erected on provided plate and box with wiring connections complete. 26 supplying and erecting isi mark modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete. 27 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 28 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 29 supplying and erecting isi mark modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 30 supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. 31 supplying and erecting isi mark modular type blanking plate two module, duly erected on provided plate & box. 32 supplying and erecting pvc surface modular switch box with double mounting plate for 2 modules duly erected. 33 supplying and erecting pvc surface modular switch box with double mounting plate for 3 modules duly erected. 34 supplying and erecting pvc surface modular switch box with double mounting plate for 4 modules duly erected. 35 supplying and erecting pvc surface modular switch box with double mounting plate for 6 modules duly erected. 36 supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 modules complete duly connected. 37 supplying and erecting pvc surface modular switch box with double mounting plate for 12 modules duly erected. 38 supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. 39 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. 40 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match thebackground. 41 supplying and erecting 16 / 20 / 25 a starter ( modular range ) 2 module for ac unit on provided box complete & duly concealed with necessary material and connected. 42 supplying and erecting isi mark modular type 5 pin socket with safety shutters 3 module socket 6a 240v ac supply, duly erected on provided plate and box with wiring connectionscomplete duly erected. 43 point wiring for light / fan / bell in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw / sw 44 point wiring for independent plug in 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as perspecification no: wg pw / sw 45 point wiring for light / fan / bell concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm. ( 2+1e ) fr grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / cw 46 point wiring for independent plug, concealed type in min 20 mm isi marked hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wires, modular type switch and socket, earthing and required accessories as per specification no wg pw / sw 47 wiring for plug on board with switch socket, copper wiring and earthing as per specification no: wg pw / sw 48 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw / sw 49 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories as per specification no: wg pw / sw 50 point wiring in pvc trunking ( casing capping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no:wg pw / sw 51 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 52 point wiring in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wgpw / sw 53 point wiring for independent plug in isi mark hms pvc conduit with 1.5 sq.mm ( 2+1e ) fr grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw 54 supplying & installing utp networking cat 6 cable suitable for lan / wan computer net working as per specification no wg coc / nc 55 dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no: wg dm / pw 56 dismantling the existing aluminium / copper mains, submains wiring upto 10 sq.mm. along with accessories etc complete as per specification no: wg dm / pw 57 supplying and erecting led square / circular 9 to 12w down lighter having pressure die cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 58 supplying and erecting led square / circular 13 to 15w down lighter having pressure die cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flushtype complete. 59 supplying and erecting square / round shaped crca / diecast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13w to18w with provision for plane front frame with translucent cover fixed to the housing complete. 60 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housingcomplete. 61 supplying and erecting led flexible strip light 5m length upto 25w conforming ip 65 of any colour with driver complete. 62 supplying & erecting led 18w tube light fitting ( 4 feet ) with polycarbonate housing, heat sink, integrated hf electronic driver complete. 63 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 64 supplying and erecting electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and ( effective range upto 45 meter ) bell on 250 v a.c. supply. 65 supplying and erecting electronic type driver for indoor led upto 19w 24w fixtures suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 66 supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminiumalloy and heat sink extruded aluminium complete per specification no . fg odf / fls2. 67 supplying and erecting led flood light fitting of 50w, including lamp, with pf > 0.95, class ip 65 and above class ip 65 and above housing of pressure die cast aluminium alloy andheat sink extruded aluminium complete per specification no fg odf / fls 2 68 supplying and erecting recess mounted 20w led wall washers, tilted 70° outwards and swivels 360° to offer best illumination on the wall with any colour with driver complete. ( including compatible driver ) 69 supplying & erecting 20w led par ( 30 lamp e 27 base, spoto series ) lights by making necessary arrangement / recess in wall to make it flush with surface. 70 supplying and erecting cylindrical shaped integral decorative with high power 12w 16w led bollard upto 1000mm with opal acrylic diffuser and ip65 protection on provided foundation complete. 71 supplying and erecting mushroom shaped integral 12w 16w led decorative bollard upto 680mm with ip65 protection on provided foundation complete. 72 erecting the departmentally supplied wp led street light / flood light fitting upto 80w. 73 erecting departmentally supplied led street light / flood light fitting upto 150w . 74 erecting departmentally supplied led street light / flood light fitting upto 400w . 75 supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb 76 maintenance of non eesl led light of all wattages of approximately 500 quantity 77 maintenance of55 nos of street light switiching box 78 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 79 supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. 80 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 81 supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5metre length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. 82 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 83 supplying and erecting fresh air cum exhaust fan of light duty250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 84 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. 85 supplying and erecting five star rated energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn / cf 86 supplying and erecting condenser 2.5 micro farad for ceiling fan 87 supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 88 providing recess in brick wall suitable forerection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. 89 providing recess in brick wall suitable forerection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 90 supplying & erecting 22 swg g.i sheet metal cawl sector shaped with 25 x 25 x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaustfan of 300 mm as per specification no fg fas / msc 91 dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with accessories, g.i. down rod, frame etc. and making the site clear. 92 providing fully comprehensive annual maintenance service for 80 / 120 / 150 ltr. water cooler unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares including minor electrical parts within 48 hours. 4 ) refrigerant charging if required. 5 ) if failed to rectify the fault within 48 hrs penalty shall be charged rs.50 / per day.the job exclude sheet metal work and plastic material. 93 providing servicing of 1 / 1.5 / 2 / 3 tr capacitysplit / window air conditioning unit complete with allnecessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to engineer incharge. 94 providing annual comprehensive maintenance contract for 1.5 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 95 providing annual comprehensive maintenance contract for 2 tr split / window air conditioning unit complete as per terms and conditions. job includes 1 ) quarterly servicing2 ) on call repair 3 ) replacement of all spares within 24 hours 4 ) sending standby manpower for vip movement. the job exclude sheet metal work and plastic material. 96 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 1.5 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 97 providing replacement of existing unservicablerotary / scroll compressor of air conditioner 2 tr by new one of same capacity with guarantee for one year with provided refrigerant complete. 98 providing replacement of unserviceable starting capacitor for a / c unit. 99 providing replacement of unserviceable running capacitor for a / c unit. 100 providing replacement of unserviceable fan motorcapacitor for a / c unit. 101 providing replacement of unserviceable pcb for a / c unit upto 3 tr capacity. 102 providing repair of of faulty pcb for air conditioning unit upto 3 tr capacity. 103 supplying and installing of new fan motor for condenser for air conditioning unit 104 providing vaccumising the airconditioner system and charging with r 22 refrigerant for air conditioning unit. 105 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 1.5tr window / split air conditioning unit. 106 providing vaccumising the airconditioner system to 200 micron and charging with r 22 refrigerant for 2tr window / split air conditioning unit. 107 providing replacement of existing unserviceablecompressor of 150 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerent with guarantee for one year. 108 providing replacement of existing unserviceablecondensor coil of 40 / 80 / 150 litre cooling capacitywater cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 109 providing replacement of existing unserviceable ss water tap of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 110 providing replacement of existing unserviceable relay 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 111 providing replacement of existing unserviceablethermostat of 40 / 80 / 150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 112 dismantling the existing split type air conditionerof any type and capacity safely without any damages and making the site clear. 113 supplying and erecting double pole metal clad switch with hc type fuse and neutral link 240v, 32a on iron / gi frame as per specification no. sw swr / mdp . 114 supplying and erecting double pole metal clad switch with hc type fuse 240v, 63a on iron / gi frame as per specification no. sw swr / mdp. 115 supplying and erecting triple pole metal clad switch and fuse 415v, 63a on angle iron / gi frame as per specification no. sw swr / mtp. 116 supplying and erecting triple pole metal clad switch and fuse 415v, 100a on angle iron / gi frame as per specification no. sw swr / mtp. 117 supplying and erecting triple pole metal clad rewireable fuse switch 415v, 200a on angle iron / gi frame as per specification no. sw swr / mtp. 118 supplying and erecting four pole metal clad on load change over switch 415v, 100a erected on angle iron / gi frame complete. 119 supplying and erecting four pole metal clad on load change over switch 415v, 200a erected on angle iron / gi frame approved make complete. 120 supplying and erecting metal clad distribution board 240v, 8 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 121 supplying and erecting metal clad distribution board 240v, 6 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 122 supplying and erecting metal clad distribution board 240v, 4 way, 16a per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 123 supplying and erecting metal clad distribution board 415 v, 8 way, 32a. per way & neutral bar connector complete erected on iron / gi frame as per specification no. swswr / mdb 124 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 125 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 126 supplying, erecting & marking spn mcb 6a to 32a, bseries ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 127 supplying, erecting & marking tpmcb 6 a to 32a in provided distribution board as per specification no. swswr / mcb 128 supplying, erecting & marking fpmcb 6a to 32a in provided distribution board as per specification no. sw swr / mcb 129 supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 130 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. swswr / mcb 131 supplying, erecting & marking tpn mcb 6a to 32a, c series in provided distribution board as per specification no. sw swr / mcb 132 supplying, erecting & marking tpn mcb 40a to 63a, c series in provided distribution board asper specification no. sw swr / mcb 133 supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 134 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 40a with required wiring connections and lugs etc. in provided distribution board complete. 135 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 63a with required wiring connections and lugs etc. in provided distribution board complete. 136 supplying erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100a with required wiringconnections and lugs etc. in provided distribution board complete. 137 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 40a in provided distribution board complete. 138 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63a in provided distribution board complete. 139 supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 80 / 100a in provided distribution board complete. 140 supplying and erecting triple pole and neutraldistribution board ( tpndb ) surface / flushmounted suitable for spmcb of 12 poles on iron / gi frame ( horizontal busbar type ) as per specification no. swswr / mcbdb 141 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 142 supplying and erecting single pole and neutral distribution board ( spndb ) surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. sw swr / mcbdb 143 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 6 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 144 supplying and erecting single pole and neutral distribution board ( spndb ) with door surface / flush mounted with 2 poles for incoming and 10 poles for outgoing sp mcb’s on iron / gi frame as per specification no. swswr / mcbdb 145 supplying & erecting original 1.25 mm crca sheet metal enclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete erected on angle iron / gi frame. 146 supplying and erecting blanking plate of suitable size on mcb db complete. 147 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 16 / 25a complete as per specification no.sw rccb / rccb 148 providing, erecting and commissioning 2 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 149 providing, erecting and commissioning 4 pole rccb only of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 40a complete as per specification no. swrccb / rccb 150 providing, erecting & commissioning 4 pole rccb of electromagnetic type with 30 / 100 / 300 ma sensitivity and having capacity of 100a, complete as per specification no. sw rccb / rccb 151 supplying & fixing crca sheet box with earthing terminals for housing 2 pole rccb on iron frame / laminated board complete. 152 supplying & fixing crca sheet box with earthing terminals for housing 4 pole rccb on iron frame / laminated board complete. 153 supplying and erecting metal work in crca sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. 154 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 155 supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 156 supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. 157 supplying and erecting gi sheet 1.6 mm ( 16 swg ) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for medium voltage installation. 158 supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions bythe authority. 159 supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 160 supplying, erecting & terminating xlpe armoured cable 3 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 161 supplying, erecting & terminating xlpe armoured cable 3 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 162 supplying, erecting & terminating xlpe armoured cable 3 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 163 supplying, erecting & terminating xlpe armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 164 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 165 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in providedtrench / pipe as per specification no. cb lt / al 166 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 167 supplying, erecting & terminating xlpe armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / cu 168 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 169 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 90 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 170 supplying & erecting water tight terminal box of 1.6 mm ( 16 gauge ) crca sheet of size 200 x 150 x 150 mm. complete on pole as per specification no. cb sb 171 supplying & erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 172 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75 m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp 173 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with provided base plate in provided foundation as per specification no. oh pl / rsj 174 supplying and erecting pre stressed cement concrete ( psc ) rectangular pole of top 105 x 115 mm & bottom of 105 x 315 mm 9 m long ( 200 kg ) complete erected in provided c. c. foundation & muffing ( square / round ) as per specification no. oh pl / psc 175 supplying & erecting ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl / bkt 176 supplying & erecting ms pole bracket, for oh conductor fabricated from ism channel, 75x40x6mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 177 supplying & erecting ms pole bracket, fabricated from ism channel, 75x40x6mm, 1100 mm long for 4 insulators and welded with extension channel pieces of same size 300 mm. in length and erecting on pole with 50x6 mm clamp as perapproved method of construction and completeas per specification no. oh pl / bkt 178 supplying and erecting all aluminium stranded conductors 7 / 3.10 mm. complete. ( ant. ) ( 145.0 kg / km ) as per specification no. oh con / aac 179 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 180 supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. ( shackle ) strips , nuts and bolts, complete. 181 supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, g.i. stay wire 7 / 10 swg, g.l. stay rod 20 mm x 1.8 m length andpole clamps duly erected in provided cement concrete foundation. 182 supplying and erecting fibre / pvc spacers for lt overhead line 3 to 5 conductors complete erected. 183 supplying and erecting ‘d’ type pole clamps, fabricated from 50 x 6 mm ms flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint. 184 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 185 dismantling the existing overhead line including g.i. wires of all sizes without damaging & making the coils in suitable sizes. 186 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep 187 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep 188 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep 189 supplying and erecting aluminium strip of required sizes used for earthing on wall and / or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required.as per specification no ea ep. 190 supplying and erecting gi strip of required size used for earthing on wall and / or any other purpose with necessary giclamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no ea ep. 191 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit withscrews in an approved manner. 192 providing printed instruction chart for treating persons suffering from electric shock, printed in english & marathi and duly laminated complete. 193 supplying and fixing pvc synthetic elastomer electrically insulating mat with class a insulation conforming to is: 15652 – 2006 & cpri tested having 2 mm thickness upto 3.3 kv 194 supplying and fixing pvc synthetic elastomer electrically insulating mat with class b insulation conforming to is: 15652 – 2006 & cpri tested having 2.5 mm thickness upto 11 kv 195 supplying shock proof leather safety shoes of electrical grade of standard size as is :11226, 14544 duly tested, with necessary test certificate from manufacturer. 196 carrying out servicing of dg set upto 50 kva with / without amf panel of any make to ensure smooth running of dg set for 30 mins on load. checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. inspect alternator, stator and rotor for normal speed & proper frequency, examine batterycharging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking v belts with necessary adjustment, checking and retightening of nut bolts including coupling boltsof engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of avr, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, cleaning of dg set internally using blower, cleaning radiator and submit the servicing report to engineer in charge. ( non comprehensive ) as per specification no. gen ser amc 197 topping up new lubricating oil 15w / 40 grade of approved make as per is 13656 : 2014 198 topping up new glycol based coolant 50 / 50 with operating range from 118°c to 37°c of approved make 199 supplying and erecting v belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for dg set upto 100kva 200 supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for dg set upto 62.5 kva. 201 supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for dg set upto 50 kva. 202 supplying and erecting stop solenoid assembly 12v / 24v single coil energized to run with or without primary etc complete suitable for dg set upto 125 kva. 203 supplying and erecting air cleaner / air filter element suitable for dg set upto 40 kva 204 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 205 making trench of suitable width and depth in hard murum / tar road for laying provided lt cable up to and including 16 sq. mm complete as per specification no. cw exnctr 206 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. 207 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing andfinishing complete. ( above 6 m to 9 m poles ) 208 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete, ( 20 to 25 ) mm stone metal with necessary curing and finishing complete. ( for stay ) . 209 making m 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with thehelp of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 210 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. specification no cw ptg / ptp. 211 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 212 rewinding motor of the 1200 / 1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption withguarantee for one year. 213 replacing the existing ball bearing of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 214 replacing the existing bush / rubber, ring, washers of table / cabin / pedestal / ceiling / exhaust fan complete with alignment of shaft & tested. 215 supplying & erecting automatic control panel for 1 ph, 230 volt, a.c.. submersible / centrifugal pump set upto 2 hp consisting of dol starter of suitable relay range s.p.p., combined ammeter / voltmeter, indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. 216 supplying and installing 25 kva koel generators generator panel with 3 years warrenty. 217 doing rewinding and repairing cooling fan of 1400rmp 220v 218 doing repairing and fixing of thebroken main gate of 25 kva generator with required accessories. 219 supplying and installing fuel cap for 25 kva generator. 220 doing servicing of highmast ( upto 15 mtr ) with lowering of lights, cleaning ropes pathway lubricating the mechanisam with all necessary accessories. 221 supplying and erecting new rope in the highmast ( upto 15 mtr ) by dismantling highmast with proper equipments. 222 maintenance of 15 nos ofdecorative pole of 15w at park...

Rural Development Department - Maharashtra

36791022 providing and fixing led street light in gaikwad wasti kharkhana tal at takali sikandar,tal mohol,dist solapur providing and fixing led street light in gaikwad wasti kharkhana tal at takali sikandar, tal mohol, dist solapur , providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl ( 8 2 13 ) , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 6600 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg odf / fls2. ( 2 4 5 ) , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl / pbkt ( 8 2 21 ) , supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb ( 5 3 7 ) , supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb / tp mcb / fp mcb / rccb / rcbo complete erected on angle iron / gi frame. ( 5 4 13 ) , supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block / box, with necessary materials. ( 4 8 2 ) , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. ( 4 8 6 ) , makingm 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . ( 16 3 9 ) , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi strandedcopper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying, erecting & terminating xlpe armoured cable 2 core 4sq. mm. aluminium conductor withcontinuous5.48 sq. mm. ( 12 swg ) g.i. earth wire completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( 7 1 4 ) , supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. ( 7 6 9 ) , 7 6 2 supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting g.i. strip of required size used for earthing on wall and / or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification no ( ea ep ) . ( 9 2 3 ) , supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority ( 6 1 19 ) , providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes. ( 16 3 7 ) , providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. ea ep ( 9 1 4 ) , msedcl charges , add18% g.s.t. chargess...

Rural Development Department - Maharashtra

36616469 providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgav providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgav tal shrigonda dist ahmednagar , providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgaon tal shrigonda dist ahmednagar , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.)3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting led street light fitting suitable for 60w lanp, iincluding lamp, with pf> 0.95 lass ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fg odf/fls 2. , supplying and erecting led street light fitting suitable for above 70w 75w lamp including lamp with pf> 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odfifls2 , supplying and erecting led flood light fitting of 90 100w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf/fls 2 , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia blass g.l. pipe 1.0 m in length along with pole ie cap of f 300 mn length 100 mm dia duly welded as er specification , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mn. dia. b grade g.l. pipe of required length complete as per specification no. fg bkt/slb , supplying, erecting and marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no. sw swrimcb , supplying, erecting and marking dpmcb 6 a to 32 ab series (for lighting) in provided distribution board as per specification no. sw swrimcb , supplying and erecting crca sheet metal one way enclosures suitable for dp mcb erected on angle iron/gi frame complete. , supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered in plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. , supplying, erecting & terminating xlpe armoured cable2 core 6 sq. mm.aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.l. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb ltial , supplying and erecting g.l. pipe a class 25 mm dia. erected for enclosing xlpe armoured cable on walllpole as per specification no. cb ce , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying and erecting steel tubular swaged pole 139.7x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5+ 1.75 + 1.75 m) length respectively and total 8 m long with pole cap base plate in provided foundation.(weight 101 kg.) asper specification no. oh pl/stp , supplying and erecting isl mark g.l. pipe pole b grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , making cement concrete foundation including excavation (60 x 60x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. /45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)...

Indian Army - Maharashtra

36392859 bids are invited for miscellaneous items 1 supply and fixing highly efficient high power multi led flood light fitting 150 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass ip66 complete prewired and connection with 0 point 5 sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by engineer in charge make bajaj havells surya crompton 2 supply and fix in repairs ceilling rose 3 terminal all as specified and directed 3 supply and fix for circuit wiring using proper colour coding with 1100 volts grade 2 point 5 sqmm pvc insulated frls unsheathed wire confirming to i 694 part ii isi marked with multistranded copper conductor drawn in and including pvc conduit minimum 25mm in width fixed on the surfaces of wall ceilling etc with all accessories fittings pvc junction boxes etc with 2 point 5 sqmm pvc insulated frls unsheathed multistranded copper conductor 1100 votls grade green color continuous earth wire connected to common earth complete all as specified and directed total quantity : 900...

Directorate Of Municipal Administration - Maharashtra

36376227 providing and fixing public gymkhana equipments in ward no. 36 2 peck deck machine 60 kg 3 lat pully 80 kg 4 seated rowing 70 kg 5 t bar 6 ab chair parallel & pull up bar 7 cable cross over ( 50+50 ) kg 8 preacher curl bench 9 preacher curl machine 60 kg 10 abdominal crunch bench 11 hyper extension cum roman chair 12 fore arm machine 50 kg 13 trade mill, 3 hp ac motor, 1.5 to 24 km / hr, 12programmes, 20 belt width frame 100 x 50 mm, pulse 14 twister 15 adjustable bench 16 elliptical 17 dumbbells stand two tire 18 weight plate stand 19 rubberized dumbbells 20 rubberized weight plate 21 steel rod 3 feet ( 25mm dia. ) 22 steel rod 4 feet ( 25mm dia. ) 23 mirror with frame ( 4’x3’ ) 24 rubber mat 2mm thick size 3x5 feet 25 leg extension & leg calf 26 leg press horizontal 100 kg 27 sqat rack 28 seated calf 29 chest press 60 kg 30 flat bench 31 decline bench with stand 32 incline bench with stand 33 smith m / c with counter weight 34 shoulder press 70 kg 35 steel rod 5 feet ( 25mm dia. ) 36 olympic rod 7 ft ( 48mm dia ) 37 zig zag rod 5 feet ( 25mm dia. ) 38 leather weight lifting belt 39 ms rod 1” dia. chrome plated with lock 40 rubber mat 2mm thick size 3x5 feet 41 programmable upright cycle 42 abdominal bench 43 trade mill, 3 hp ac motor, 1.5 to 24 km / hr, 12 programmes, 20 belt width frame 100 x 50 mm, pulse 44 vibrator belt 45 elliptical 46 supply, fixing and installation of 4mm thick aluminium composite panel ( acp ) of approved colour for external cladding in combination of solid and metallic colours, including all necessary framework, support and complete weather sealing as per architectural drawing. the aluminium composite panel ( acp ) should be made out of thermoplastic core of low density polyethylene ldpe ( 100% virgin mix ) , sandwiched between two aluminium sheets of alloy grade 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have stove lacquered finishing coat not less than ( 26 + 2 ) micron ( containing minimum 70% kynar 500 based pvdf ) of colour and shade as per architectural design. the inside surface ( facing the building exterior surface ) shall have polyster based powder coating not less than 25 micron with protective peel off foil on the exterior face ( peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off ) . the supporting framework shall be made out of 50 mm x25mm x 3mm thick aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm x 1200 mm and fixed to the building structure as per design through 50mm x50mm x5 mm ms angle clamps prefixed to masonry or slab, columns with hilti make anchor fastener screws. the fixing of panel to be done with the help of vhb tapes and screws and all the sealing of joints to be done with weather sealent silicon as directed by engineer in charge. ( prior permission of s.e. is necessary before inclusion of this item in estimate ) 47 supply & application of synthetic seamless full pu ( plyurethane ) sports flooring system 48 movable badminton pole 49 rubber mat 36mm thk. with 100 mm pcc per sq mtr 50 providing and fixing 12mm thk toughened etched glass as per the design, as per the design. glass to be fixed at top & bottom in heavy guage aluminium c channel concealed in floor & boxing. cost to be inclusive of silicon sealant to the periphery of the glass as directed. 51 preparing shrubbery excavation th eground top reqired depth of 30cm, removing & conveying unwanted stuff to a requierd distance as directed. filling fresh garden soil & manur in excavated area in 3:1 proportion to a height of 30cm. mixing garden soil & manure throughly well, leveling & watering on previous night, planting well devloped shrubs plant 0.5m apart as directed and maintaning till well establlished by watering, weeding, stirring, replacing casualities etc complete. 52 planting large flowring / shaddy tree ( ht 2m ) digging pit with size 0.9mx0.9x0.9m removing & conveying unwanted stuff to a required distance as directed, filling the pit with approved excavated materila upto a height of 0.30m & remaing height of 0.6m with fresh garden soli & manure throughly well, levelling as directed watering previou night, planting to 2 3 yar old minimum 2m height, healthy trees sapling as per specification. maintaning till well established by watering, weeding, stirring of tree. 53 channelled wall panelling of size: 192x2400x15mmproviding and fixing channelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a moisture resistant fibre board substrate with a laminated facing as per the approved shade ( portland maple, sea beech, siam wood & mystique walnut, interior white, alumina pearl ) and a melamine balancing layer on the reverse side. the boards shall have a special perforation pattern where the reverse surface has a ?helmholtz? fluted perforation with consecutive 3mm wide groove followed by 13mm or 21mm of visible pane ( g 13 / g 21 ) . the edges of the panel shall be ?tongue and grooved? to fix special clips for installation and seamless visual. the back of the perforated panel shall have sound absorbing non woven soundtex acoustical fleece hot pressed to achieve nrc of 0.5. for g 21 and 0.6 for g 13. ( average value of absorption co efficient readings taken at 250 hz, 500 hz, 1000 hz and 2000 hz ) as per astm c423 and humidity resistance ( rh ) of 70% with camber limit less than 1mm / 1000mm and bow less than 1mm / 300mm.the panels shall be mounted on special aluminium splines ( keel ) using inside clips provided by manufacturer and approved by the architect / engineer in charge. 54 excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. ( lift upto 1.5 m. ) by mechanical means 55 providing dry / trap / granite / quartzite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. 56 providing and laying cast in situ / ready mix cement concrete in m 10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based plc with scada enabled reversible drum type mixer / concrete batch mix plant ( pan mixer ) etc. complete. with fine aggregate ( crushed sand vsi grade ) 57 providing and laying machine cut machine polished kota stone flooring 25mm to 30mm thick and required width in plain / diamond pattern on bed of 1:6 c. m. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 58 providing and fixing polycarbonate multiple wall sheet roofing 20mm thick gauge of approved make uv coated of approved make and of approved colour and with aluminium framing for fixing polycarbonate sheet using pressure plates with epdm gasket ( compatible to polycarbonate ) breather tape, screws and covering the pressure plates complete and making the entire system water tight by using sealant as per architectural drawings and specification. ( rate does not include cost of structural steel framing which will be paid seperately ) 59 providing and fixing mild steel grill railing weighing 20kilogram / square metre. with pvc handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing pvc handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete.spec. number : as directed by engineer in charge. 60 providing and applying two coats apex ultima puranature anti pollution or equivalent approved brand, paint should decomposes organic substances and inorganic gases ( nox, voc‘s, co, sox, formaldehydes, etc. ) in presence of natural or artificial light. it contains graphene and nanoparticles of titanium oxide. and absorbs co2 ( 4.8 kilogram / 15 l ) . plaster crack should be filled by acrylic base crack seal / textured crack filler, paint has to applied on one coat of apex ultima puranature anti pollution primer or equivalent. warranty should be given by the manufaturer the work should be done by the manufacturerrecommended applicator and he should be able to furnish stage wise onsite technical reports from theconcerned company technologist. 61 providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per is 4923 yst 310 grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. 62 providing and fixing corrugated galvanised iron sheets of 0.63mm thick ( 24 b.w.g. ) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. ( weight of 5.5 kilogram / sq.m. ) 63 providing and fixing plain zinc sheeting of 0.80 mm thick ( 22 b.w.g. ) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete. ( weight of 6.8 kilogram / sq.m. ) . 64 providing and fixing valley gutter of 22 b.w.g. ( 0.8 mm ) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal tarring the upper surface of plank etc. complete. ( excluding painting to underside of plank ) . 65 providing and fixing p.v.c. rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to i.s. 13592 1992 including proper rainwater receiving recess with p.v.c. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number , filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on c.c. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. all the p.v.c. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. 66 providing and fixing rollar blinds ami make or approved make & shade of 38mm round aluminium channel with blackout fabric & telting with chain ( ball ) system with all necessary fixtures and fitting etc. complete. ( sample to be final by engineer in charge prior execution of work ) 67 chest press 68 fore arm twirl pg ft 02 69 hip twister 70 leg extension 71 ovat stepper 72 shoulder extension 73 shoulder twister / twirl 74 airo cycle 75 air walker 76 excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. ( lift upto 1.5 m. ) 77 filling in plinth and floors with contractors material / brought from outside and approved by engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 78 providing dry / trap / granite / quartzite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. 79 providing and laying cast in situ / ready mix cement concrete in m15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood / steel formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. the cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. ( wooden centering will not be allowed. ) , with fully automatic micro processor based plc with scada enabled reversible drum type mixer / concrete batch mix plant ( pan mixer ) etc. complete. with natural sand / v.s.i. quality artificial sand 80 providing and laying cast in situ / ready mix cement concrete m 25 of trap / granite / quartzite / gneiss metal for r.c.c. work in foundations like raft, strip foundations, grillage and footings of r.c.c. columns and steel stanchions etc. including bailing out water, formwork , cover blocks, laying / pumping, compaction and curing roughening the surface if special finish is to be provided ( excluding reinforcement and structural steel ) etc. complete, with fully automatic micro processor based plc with scada enabled reversible drum type mixer / concrete batch mix plant ( pan mixer ) etc. complete. with natural sand / v.s.i. quality artificial sand 81 providing and laying cast in situ / ready mix cement concrete m 25 of trap / granite / quartzite / gneiss metal for r.c.c. slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. ( excluding reinforcement and structural steel ) .with fully automatic micro processor based plc with scada enabled reversible drum type mixer / concrete batch mix plant ( pan mixer ) etc. complete. with natural sand / v.s.i. quality artificial sand 82 providing and laying cast in situ / ready mix cement concrete in m 25 of trap / granite / quartzite / gneiss metal for r.c.c. pardi of required thickness including centering, formwork, cover blocks, laying / pumping, compacting and roughening them if special finish is to be provided and curing complete. ( excluding reinforcement and structural steel ) .with fully automatic micro processor based plc with scada enabled reversible drum type mixer / concrete batch mix plant ( pan mixer ) etc. complete. with natural sand / v.s.i. quality artificial sand 83 providing and fixing in position tmt fe 500 bar reinforcement of various diameters for r.c.c. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 84 manholecs ps 178 supplying and fixing c.i. cover without frame for manholes : b ) cs ps 178 b 500 mm diameter c.i. cover ( medium duty ) the weight of the cover to be not less than 58 kg 85 providing internal cement plaster 20mm thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete 86 providing and applying required coats of a water based uv resistant evercrete top seal sealant to protect natural stone, bricks, concrete and wooden structures from water intrusion and staining due to water penetration and algue formation etc complete 87 providing and fixing on walls / ceiling / floor 15 mm dia. cpvc pipe with necessary fittings, remaking good the demolished portion etc. complete. including removing existing pipe line if necessary and conveying and stacking the same in pwd chowky or as directed etc. complete. 88 providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick bats. 89 providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in c.m. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1 / 2:3 including scaffolding and fourteen days curing complete. 90 c.p.angular stop cock jaquar make continental ( cat.no. con 053 ) 91 supplying and erecting corridor / passage light fitting ( 2 feet ) including 9w led lamp, comprises of extruded channel in plastic silver grey colour & with same plastic end cap on provided pvc block / wooden board. 92 point wiring for light / fan / bell concealed typenin min 20 mm pvc conduit with 1.5 sq.mm. ( 2+1e ) fr grade copper wires, moduler type switch, earthing and requiredaccessaries as per specification no: wg pw / cw 93 wiring for plug on board withswitch socket concealed typeand copper wiring, earthing and with modular accessories as per specification no: wg pw / cw 94 supplying & erecting mains with 2x4 sq.mm.and earth wire 2.5 sq.mm fr pvc copper wirein rigid pvc conduit min. 20mm dia, as per specification no: wg ma / pc, para no. 1.4. 95 supplying & erecting mains with 2x2.5 sq.mm.and earth wire 1.5 sq.mmfr pvc copper wire, in rigid pvc conduit min. 20mm dia, as per specification no: wg ma / pc, para no. 1.4.1 96 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 97 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution boardas per specification no. swswr / mcb 98 supplying, installing, testing and commissioning of 2500 va digital pure sine wave inverter based on insulated gate bipolar transistor ( igbt ) technology single phase 230v, 50 hz complete as per specification no. ap inv ( without batteries ) 99 supplying and erecting 12 v / 200ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 100 supplying, installing, testing and commissioning split type variable speed inverter technology room air conditioning unit 1.5 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hiwall / floor mounting type complete with refrigerant r410 a / r32 and copper condenser at position. specification no. apac / sac 101 providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm complete with all materials, testing & recording theresults as per specification no. ea ep 102 point wiring for independent plug in 20 mm metal conduitwith 1.5 sq.mm ( 2+1e ) fr grade copper wire, flush type switch, earthing and required accessories as per specification no: wgpw / sw 103 testing charges+royalty...

Directorate Of Municipal Administration - Maharashtra

36337176 material supply for electrical department for operation,maintainance and various works for annual year 2023 2024. , supplying & erecting mains with 2x1.5 sq.mmf.r copperpvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with isi markwp 2 x 2.5sq. mm. 1100 v grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series (for motor/power) in provided distribution board as per specification no. sw swr/mcb , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led flexible strip light 5m length upto 25w conforming ip 65 of any colour with driver complete. , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting fresh air cum exhaust fan of light duty250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected in an approved manner. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 modules duly erected. , supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , supplying, erecting & terminating xlpe armoured cable 3 core10sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 swg) g.i. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb lt/al , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying, erecting & terminating xlpe armoured cable 2 core 10sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 swg) g.i. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. cb lt/al , supplying, erecting & terminatingxlpe armoured cable 4 core10sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 swg) g.i. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe , supplying & erectingwater tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300x200 x 150 mm complete on pole , supplying & erecting frp box of size 250 x 200 x 100 mm, 2.7 mm thick complete on pole/wall , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting street light bracket made from 25 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , making cement concrete foundation including excavation(60x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45x 45x 45)cm /45 cm dia. x45cm height plinth duly plastered,with necessary curing and finishing complete. (above 6 m to 9 m poles) , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. ea , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting porcelain shackle type lt medium insulator 75x115 mm dia. with g.i. (shackle) strips , nutscomp. , supplying and erecting fibre/ pvc spacers for lt overhead line 3 to 5 conductors complete erected. , supplying & installing utp networking cat 6 cable suitable for lan / wan computer net working as per specification no. , providing temporary illumination consisting of flood light 1000/500w, 230v, 50hz complete halogen fitting with lamp, holders, mains and requiredswitchgears with continuous earth wire erected and dismantled with scaffolding up to three days. , providing, commissioning and maintaining temporary cctv system with 8 channel nvr, ip video/audio input 1 no, ip based 2.0 mp, full hd, ir ip dome camera 2 nos,ip based 2.0 mp, full hd, ir ip ptz camera 2 nos, 2tb hard disk 2 no, 32 full h d professional display 1 no, 8 port poe switch 1 no, power supply unit to camera 1 no, on line ups ups 1 no with necessary mains, switchgears on hire basis for one day , hiring charges for supplyingand maintaining 230/415 v, 50 cycles acgenerating set3 to 10 kvacapacity with necessaryfuel,mains,switchgears and accessories complete with continuousrunning onload/no load as per requirements completewith self certification....

Rural Development Department - Maharashtra

36285709 providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgav providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgav tal shrigonda dist ahmednagar , providing following materials for work providing led street light in the premises of shree chandeshwer devasthan at chandgaon tal shrigonda dist ahmednagar , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.)3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting led street light fitting suitable for 60w lanp, iincluding lamp, with pf> 0.95 lass ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fg odf/fls 2. , supplying and erecting led street light fitting suitable for above 70w 75w lamp including lamp with pf> 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odfifls2 , supplying and erecting led flood light fitting of 90 100w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf/fls 2 , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia blass g.l. pipe 1.0 m in length along with pole ie cap of f 300 mn length 100 mm dia duly welded as er specification , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mn. dia. b grade g.l. pipe of required length complete as per specification no. fg bkt/slb , supplying, erecting and marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no. sw swrimcb , supplying, erecting and marking dpmcb 6 a to 32 ab series (for lighting) in provided distribution board as per specification no. sw swrimcb , supplying and erecting crca sheet metal one way enclosures suitable for dp mcb erected on angle iron/gi frame complete. , supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered in plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. , supplying, erecting & terminating xlpe armoured cable2 core 6 sq. mm.aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating xlpe armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 swg) g.l. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb ltial , supplying and erecting g.l. pipe a class 25 mm dia. erected for enclosing xlpe armoured cable on walllpole as per specification no. cb ce , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and erecting frp box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying and erecting steel tubular swaged pole 139.7x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5+ 1.75 + 1.75 m) length respectively and total 8 m long with pole cap base plate in provided foundation.(weight 101 kg.) asper specification no. oh pl/stp , supplying and erecting isl mark g.l. pipe pole b grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , making cement concrete foundation including excavation (60 x 60x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. /45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)...

Rural Development Department - Maharashtra

36217891 providing and fixing led street light light in bhim nagar tarapur road at penur, tal.mohol providing and fixing led street light light in bhim nagar tarapur road at penur, tal.mohol , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no.oh pl/opl. , supplying and erecting integrated led street light fitting suitable for 60w ip 65 and ik08 class having single piece pressure de cast alluminium housing having system lumens output of min 6600 k thd <10% p.f. > 0.95 operatng range of 140 270 v inbuilt surge protection of 10kv life class of 50000 hrs at l 70850 including driver , providing & erecting galvanised 1000 mm single arm sword type bracket with frpdemo and ball as per specfication no ch pl/pkbt , supplying, erecting & marking dpmcb 6 a to 32 a b series (for lighting) in provided distribution board as per specification no. sw swr/mcb(5 3 7) , supplying and erecting crca sheet metal one way enclosures of 1.2 mm thickness suitable for dp mcb/ tp mcb/fp mcb/rcc rcbo complete erected on angle iron / gi frame , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) in provided distribution board as per specification no.wswr/ mcb(5 3 3) , supplying and erecting two pole power contactor 250v 12a for time switch complete erected on wooden block/provided box, with necessary materials. (4 4 2) , supplying and erecting programmable digital almanac timer micro controller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respctively automatically having 4 digit led , providing & casting of m 20 grade reinforced cement concrete (rcc) foundation suitable for 9m & 10m raising lowering high mast considering the safe soil bearing capacity at site as 10 t/sq m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template as per design in an approved manner.(16 3 9) , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 30) , supplying, erecting & terminating pvc armoured cable 2 core 4 sq mm aluminium conductor with continuous 5.48 sq mm (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al (7 1 5) , supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete.(7 6 11) , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing pvc armoured cable on wall/pole as per specification no. cbce(7 6 1) , supplying and erecting gi strip of required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification no ea ep. (9 2 3) , supplying and erecting led street light fitting suitable above 26w to 36w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die castluminium alloy and heat sink extruded aluminium complete as per specification no fg odf/fls2 , supplying and erecting street light bracket made from 25 mm. dia ‘b’ class g.i. pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying & erecting mains with 2x2.5 sq.mm f.r copper pvcnsulated wire laid in provided conduit/trunking/insideole/bus bars or any other places. as per specification no: wg ma/bw (1 3 5) , supplying and erecting iron, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority ( 6 1 19) , providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes (16 3 6) , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep(9 1 4) , msedcl chargess , add18% g.s.t. chargess...

Military Engineer Services - Maharashtra

35967244 8337 repair / replacement of internal wiring fittings fixtures and connected electrical items in single living accn 450 / 264 personnel line single officer / jcos / ors / nursing accn at afmc under ge ( central ) pune & f modular switch flushtype, single pole, one way, 6 / 10 amps complete. 3 s & f modular switch flush type, single pole, one way, 15 amp complete. 4 s & f modular switchflushtype, single pole, two way, 6 / 10 amps complete. 5 s & f bell push modular 6 amps complete all as specified. 6 s & f modular socket outlet multipurpose socket, 6 amps , 2 / 3 pin combined flush type complete. 7 s & f modular socket outlet multipurpose socket 6a / 16 amps, 2 / 3 pin combined flush type complete. 8 s & f modular step type fan regulator single module 230 volt 50 hz, ac supply complete. 9 s & f modular step type fan regulator two module 230 volt 50 hz, ac supply complete. 10 s & f switch piano flushtype, single pole, one way, and 5 amp complete 11 s & f switch piano flushtype, single pole, two way, and 5 amp complete . 12 s & f bell push 6 amp 230 volt, 50 hz , ac supply complete. 13 s & f switch piano flush type, single pole, one way, and 15 amp complete. 14 s & f socket outlet multipurpose having provision for 2 in 1, 3 pin, 5 amp flush type complete. 15 s & f socket outlet multipurpose having provision for 2 in 1, 3 pin, 5 amp and 15 amp, flush type complete. 16 s & f switch socket combination multipurpose2 in 1, 3 pin, 5 and 15 amp flush type universal complete. 17 s & f switch socket combination multipurpose2 in 1, 5 amps flush type universal complete. 18 s & f ceiling fan regulator socketed, stepped type, flush type, 230 volts, ac supply complete 19 s & f ceiling rose, surface bakelitetype, isimarked for batten fitting complete all as specified. 20 s & f lamp holder, pvc / polycarbonate type with back plate complete all as specified. 21 s & f bell electric ding dong type 230 volt, 50 hz , ac supply complete all as specified. 22 s & f capacitor 2.50 / 3.15 / 4.00 mfd, 230 volts, ac complete 23 s & f plug top 3 pin, 15 amps, 230 volts ac complete 24 s & f pvc surface modular box of size up to 6 modulewith modular plates inner and outer with each terminal including necessary fixing arrangements completeall as specified.. 25 s & f pvc surface modular box of size 8 to 12 modulewith modular plates inner and outer with each terminal including necessary fixing arrangements completeall as specified.. 26 s & f in replacement ofsurface mounted round led down light fittings 18 watt with aluminium die cast body, finished with drop down pc diffuser to deliver low glare illumination with optimised heat sink for efficient heat dissipation, 230 volts with all accessories internally prewired andnecessary mounting arrangements complete all as specified. 27 s & f in replacement led tube light fittingswall / ceiling mounted, 20 watt led 6500k with ultra bright led polycarbonate tube light with very high efficiency provided with high efficient integral constant current led driver 230 voltsetc. complete with mounting batten including all accessories internally prewired and including provision of new 3 core multistrandedcopper conductor of suitable size from ceiling rose to fitting completeall as specified and as directed. 28 s & f in replacement for wall mounted 20 watts indoor batten with opal diffuser, ip 20, with minimum 3 hrs back up with output of 1800 lumens, powerful lithium battery, boxtype light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally prewired andnecessary mounting arrangements including provision of new 3 core multistrandedcopper conductor of suitable size from ceiling rose to fitting completeall as specified. and as directed. 29 s & f wall / ceiling mounted led batten tube light fitting, 10 watts, , with out put of 1000 lumens, 230 volts with extruded aluminium housing with decorative end caps and intregrated electronic driverconnector block etc complete with all accessories internally prewired andnecessary mounting arrangements including provision of new 3 core multistrandedcopper conductor of size 23 / 0.193 from ceiling rose to fitting including led tube 2 x 10 watts complete all as specified. and as directed. 30 s & f led security light fittings of luminaires 24 watt complete with all accessories and including wall mounting bracket of suitable size including clamps, nuts & bolts etc.including all accessories internally prewired including provision and connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 0.6 to 0.9 mtr long bend to required shape with clamps, nut, bolts completeall as specified. and as directed. 31 s & f sleek round recessed mounting led downlight fitting 15 watts with al die cast body, finish with drop down pc diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation, 230 volts with integrated electronic driver connector block etc complete with all accessories internally prewired and necessary fixing arrangements including provision of new 3 core multistranded copper conductor of suitable size complete all as specified. and as directed. 32 taking down ceiling fan , sealing cable ends, dismantling blades and depositing to store yard of age e / m for reused complete all as directed. 33 hanging only ceiling fan and connecting up including provision of cable fron ceiling rose or connnector to fan complete all as directed.note : ( i ) ceiling fan taken down from item no 32 above shall be used for hanging only. ( ii ) necessary receipt vouchers / issue voucher shallbe made after depositing of ceiling fan to store yard of age e / m and taken back for hanging only . 34 s & fin replacement of copper conductor pvc round sheathed ( flexible ) industrial cable 3 core, 1.5 sqmm complete all as specified and as directed. 35 s & fin replacement of copper conductor pvc round sheathed ( flexible ) industrial cable 3 core, 2.5 sqmm complete all as specified and as directed. 36 m & l for sub main wiring complete with two single core 4 sqmm, 1100 volts grade, pvc insulated, strandedcopper conductor frls cable with continuous copperearth conductor of one run of single core 4 sqmmdrawn throughin and including non metallic pvc rigid conduit of suitable size including all accessoriesincluding taking down old unserviceable / worn out sub main wiring of any type complete includingmaking good of disturbed surfaces all as specified and as directed. note : 2 runs of 4 sqmm conductor, one run of 4 sqmm earth conductor and one run of pvc conduit shall be measured as one unit length. 37 m & l for sub main wiring complete with two single core 6 sqmm, 1100 volts grade, pvc insulated, strandedcopper conductor frls cable with continuous copperearth conductor of one run of single core 6 sqmmdrawn throughin and including non metallic pvc rigid conduit of suitable size including all accessoriesincluding taking down old unserviceable / worn out sub main wiring of any type complete includingmaking good of disturbed surfaces all as specified and as directed. note : 2 runs of 6 sqmm conductor, one run of 6 sqmm earth conductor and one run of pvc conduit shall be measured as one unit length. 38 m & l for sub main wiring complete with four single core 4 sqmm, 1100 volts grade, pvc insulated, strandedcopper conductor frls cable with continuous copperearth conductor of one run of single core 4 sqmmdrawn throughin and including non metallic pvc rigid conduit of suitable size including all accessoriesincluding taking down old unserviceable / worn out sub main wiring of any type complete includingmaking good of disturbed surfaces all as specified and as directed. note : 4 runs of 4 sqmm conductor, one run of 4 sqmm earth conductor and one run of pvc conduit shall be measured as one unit length. 39 m & l for sub main wiring complete with four single core 6 sqmm, 1100 volts grade, pvc insulated, strandedcopper conductor frls cable with continuous copperearth conductor of one run of single core 6 sqmmdrawn throughin and including non metallic pvc rigid conduit of suitable size including all accessoriesincluding taking down old unserviceable / worn out sub main wiring of any type complete includingmaking good of disturbed surfaces all as specified and as directed. note : 4 runs of 6 sqmm conductor, one run of 6 sqmm earth conductor and one run of pvc conduit shall be measured as one unit length. 40 taking down carefully aluminium point wiring ( light, fan, socket or power ) , complete ( fitting such as switches, sockets, holders, light fittings, fan requlators etc ) and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. 41 m & l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sqmm ( nominal area ) , two single core, pvc insulated and unsheathed frls cable 1100 volts grade, isi 694 marked drawn through in and including heavy duty, pvc conduit / casing capingof 25mm size including all accessories etc, with modular sunken / surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment, covered with modular white cover plate with frame suitable for modular switches or pvc surface mounted modular box, including pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frls cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following : 42 ( a ) one light / fan pointcontrolled by one, one way switch complete all as specified and as directed. 43 ( b ) one light point controlled by two, two way switch complete all as specified and as directed. 44 ( c ) one bell point controlled by one, bell push complete all as specified and as directed. 45 ( d ) one 3 pin 5 amps switch socket outlet point controlled byone, one way switch on independent board complete all as specified and as directed.. 46 ( e ) one 3 pin 5 amps switch socket outlet point controlled byone, one way switch on the same board complete all as specified and as directed.. 47 all as per item no. 40 above but with multistranded copper conductor 2.5 sqmm ( nominal area ) , single core, pvc insulated and unsheathed multistranded frls cable 1100 volts grade isi 694 markedfor 3 pin, 15 amp socket outlet, independent, including pvc insulated multistranded copper conductor 2.5 sqmm ( nominal area ) single core frls cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. 48 m & l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sqmm ( nominal area ) , two single core, pvc insulated and unsheathed frls cable 1100 volts grade, isi 694 marked in pvc rigid conduits of25mm size heavy duty isi marked totally concealed in wall / floor / roof including all accessories etc, with modular sunken boxes with modular white cover plate with frame suitable for modular switches / sockets and pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frls cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following : note ( i ) cutting in chases and pointing in will be done by contractor without any extra cost to the department. rates quoted by the contractor shall deemed to be included of above provision. 49 ( a ) one light / fan pointcontrolled by one, one way switch complete all as specified and as directed. 50 ( b ) one light point controlled by two, two way switch complete all as specified and as directed. 51 ( c ) one bell point controlled by one, bell switch omplete all as specified and as directed. 52 ( d ) one 3 pin 5 amps switch socket outlet point controlled byone, one way switch on independent board complete all as specified and as directed. . 53 ( e ) one 3 pin 5 amps switch socket outlet point controlled byone, one way switch on the same board complete all as specified and as directed.. 54 all as per item no. 42 above but with multistranded copper conductor 2.5 sqmm ( nominal area ) , single core, pvc insulated and unsheathed multistranded frls cable 1100 volts grade isi 694 markedfor 3 pin, 15 amps socket outlet, independent, including pvc insulated multistranded copper conductor 2.5 sqmm ( nominal area ) single core frls cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. .. 55 supply & fix in replacementmcb tp / tpn rated capacity upto 40 amps, 415 volts breaking capacity 10 ka b curve complete all as directed. 56 supply & fix inin replacementmcb tpn rated capacity upto 63 amps, 415 volts breaking capacity 10 ka b series complete all as specified. 57 supply & fix inin replacement mcb spn / dp rated capacity 32 amps, 240 volts breaking capacity 10 ka b series complete all as directed. 58 supply & fixin replacement mcb sp rated capacity 5 to 32 amps, 240 volts breaking capacity 10 ka b curve complete all as directed. 59 supply & fixin replacement mccbtp415volts 16 ka of capacity 63 to 100amps with extended spreaded terminals complete all as directed. 60 s & fin replacement sheet metal enclosure mcbdbtpn4 way with 200 amps rated bus bar 415 volts suitable for fixing double door with magnetic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed. 61 s & fin replacement vertical type double door tpn db 8 way ip 43 recess mounted / wall mounted typewith incoming mccb 3 pole 25 ka 100 amps and outgoing mcb sp 32 amps suitable for single phase / three phase out going includingincluding necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed 62 s & fin replacement sheet metal enclosure mcbspn db12 way with 200 amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed. 63 all as per item no 51 above but mcb db 8 way 64 all as per item no 51 above but mcb db 6 way 65 all as per item no 51 above but mcb db 4 way 66 s & f in replacement sheet metal enclosures single pole and neutral enclosure with a three pin and earth plug and socket complete with one mcb sp 20 / 32 amps including removal of old unserviceable one complete all as directed. 67 m & l for servicing / testingofmetering indoor building panels, 03 / 01 phase, 415 / 230 volts all as specified and as directed as per followings. ( i ) repair / replacement of damaged hinges and locks / latches of each compartment. ( ii ) cleaning of existing bus bars with ctc with applyingred solution, providing bus bar insulation & refixing with new nuts / bolts / washers etc. ( iii ) replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each mccb / mcbs switches, terminals to bus bars including connector. ( iv ) replacement of damaged cable protection pipe and damaged / wornout cable lugs of any size for incoming & outgoing cables ( v ) replacement of neoprene gasket and transparent acrylic sheet 3mm for all doors of panel board. ( vi ) repainting ofpanels after removing the rusting, scrapping, cleaning and drying the surfaces complete. ( vii ) running welding wherever required ( viii ) replacement of unserviceable mccb / mcbs. ( note : mccb / mcb shall be measured & paid separately under relevant items ) ( ix ) removing, cleaning and refixing of electric meter including connection of concerned accn complete 68 m&l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically ( earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil / strata and testing on completion. note: gi earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 69 m & l in replacementearth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete...

Walchand College Of Engineering - Maharashtra

35946673 tender for electrification work with material and labour charges in innovation, incubation, entrepreneurship (iie) cell and new dean cabins at wce, sangli 1 supplying and erecting pvc surface modular switch box with double mounting plate for 6 modules duly erected. (csr item no. 1 8 30 page no. 14) 2 supplying and erecting pvc surface modular doublemounting plate 6 modules complete duly erected. (csr item no. 1 8 50 page no. 16) 3 supplying and erecting pvc surface modular double mounting plate 8 modules complete duly erected. (csr item no. 1 8 50 page no. 16) 4 supplying and erecting pvc surface modular switch box with double mounting plate for 12 modules duly erected. (csr item no. 1 8 30 page no. 14) 5 supplying and erecting isi mark modular type switch 6a /10a duly erected on provided plate and box with wiringconnections complete. (csr item no. 1 8 1 page no. 13) 6 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. (csr item no. 1 8 10 page no. 14) 7 supplying and erecting isi mark modular type blanking plate one module, duly erected on provided plate & box. (csr item no. 1 8 24 page no. 14) 8 point wiring in pvc trunking (casing capping) with 1.5sq.mm (2+1e) fr grade copper wire, modular type switch,earthing and required accessories(csr item no. 1 9 25 page no. 18) 9 supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. ( csr no. 1 7 13 page no.12 10 supplying and erecting for mains running 2x2.5 sq.mm. and earth wire 1.5 sq.mm fr pvc copper wire, pvc conduit /casing capping (csr item no. 1 6 4 page no.10) (db to first table switch board) 11 supplying and erecting for mains running 2x1.5 sq.mm. and earth wire 1.0 sq.mm fr pvc copper wire laid in provided pvc conduit /casing capping (csr item no. 1 6 1 page no.10) (switch board to switch board running) 12 supplying & erecting mains with 3x2.5 and earth wire 1.5 sq.mm fr pvc copper wire laid in provided pvc conduit /casing capping (csr item no. 1 3 11 page no.06) ( db to first table running ) 13 supplying & erecting mains with 2x1.5 sq.mm and earth wire 1.5 sq.mm fr pvc copper wire. laid in provided conduit/trunking/inside pole/bus bars or any other places (csr item no. 1 3 1 page no.05) (switch board to switch board) 14 supplying, erecting & terminating xlpe armoured cable 4core 10 sq. mm. aluminium conductor with continuous5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe (csr item no. 7 1 28 page no.126) ( db box to computer db) 15 supplying, erecting & terminating xlpe armoured cable 4core 50 sq. mm. aluminium conductor with continuous5.48 sq. mm. (12 swg) g.i. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe (csr item no. 7 1 32 page no.126) ( exam cell panel to i.e.e cell busbar) 16 supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. (csr no. 7 6 11 page no.139) 17 supplying and erecting & marking spmcb 6a to 32a, c series(for motor/power) in provided distribution board as perspecification no. sw swr/mcb (csr no. 5 3 2 page no.94) 18 supplying and erecting & marking dpmcb 6 a to 32 a b series (for lighting) in provided distribution board as per specification no. sw swr/mcb (csr no. 5 3 7 page no.94) 19 supplying and erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. swswr/mcb(csr no. 5 3 17 page no.94) 20 supplying wall/table fan of a.c. 230 v. 50 cycles 400 mm.oscillating type complete with 2 mtrs. of 3 core flexible wire and hand shield type 3 pin plug top (csr no. 2 12 10 page no.42) 21 supplying and erecting regular/ standard model ceiling fan of1400mm. sweep complete erected in position (csr item no. 2 12 3 page no. 41) 22 supplying and erecting exhaust fan medium duty 230 v a.c.50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. ( csr item no. 2 12 15) 23 supplying and erecting triple pole and neutral distribution board (tpndb) surface/ flush mounted suitable for spmcb of 12 poles on iron / gi frame (horizontal busbar type) (csr item no. 5 4 1, page no.96 24 erecting for necessary accessories in wall/floor with chiselling and cover with plastering appropriately ( csr item no. 1 1 7 page no. 3) 25 supplying and erecting rcc chamber cover with frame 60cm x 45cm medium duty 100kg with lifting arrangement including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed / embedded on top of chamber complete. (csr item no. 16 2 4 page no.243 civil csr) 26 supply & installation of chemical earthing with copper rod earthing & necessary accessories complete (earthing wire also provide to earth pit to source ....

Airports Authority Of India - Maharashtra

35904306 tender for associate electrical works for operationalization of new terminal building ( sh: relocation of fire pump room. ) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. (b) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) suitable cement concrete foundation duly plastered with anti vibration pads.2850 lpm at 70 m head to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet. (the pump shall be capable of giving a discharge of not less than 150% of the rated discharge at a head of not less than 65% of the rated head and motors for main fire pumps shall be at least equivalent to the horse power required to drive the pump at 150% of its rated discharge and shall be designed for continuous full load duty. ) 2 supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. (b) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) suitable cement concrete foundation duly plastered and with anti vibration pads.2850 lpm at 70 m head to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet. (the motro shall be designed at least 20% greater than the maximum hp required to drive the pump at its duty point. it shall also be capable of driving the pump at 150% of the rated discharge at 65% of rated head.) 3 supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump) (a) horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520. (b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is : 325. (c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 70 m head ( hp for pump shall designed considering item no. 01 and 02 above) 4 fabrication, supply, insallation testing & commissioning of electrical control panel detailed description as per soq sl. no. 4 of tender document 5 providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589/is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 6 50 mm dia 7 80 mm dia 8 150 mm dia 9 200 mm dia (wall thickness 6.3 mm) 10 providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in/on ground including welding, excavation (if in ground) & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape (if in ground) as per is 10221, painting, refilling the trench (if in ground) etc. of following sizes complete as required.150 mm. dia 11 supplying, fixing, testing & commissioning of double flanged sluice valve of rating pn 1.6 with non rising spindle, bronze/gun metal seat, isi marked complete with nuts, bolts, washers, gaskets and conforming to is 780 of following sizes as required : 12 80 mm dia 13 150 mm dia 14 200 mm dia 15 supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : 16 50 mm dia 17 80 mm dia 18 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required : 19 80 mm dia 20 150 mm dia 21 providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 22 80 mm dia 23 150 mm dia 24 200 mm dia 25 supplying and fixing air vessel made of 250 mm dia, 8mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 26 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. 27 providing & fixing pressure gaugeof range 0 14kg/cm2 or more in following sizes m.s. pipe including connection etc as required.150 mm dia 28 providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150 mm dia 29 providing, fixing, reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 16 kg/cm2 pressure, as per specification of the manufacturers complete as required and as specified. 30 150 mm dia 31 80 mm dia 32 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)8 way, double door 33 supplying and fixing following rating, double pole, (single phase and neutral), 240v, residual current circuit breaker (rccb), having a sensitivity current 30ma in the existing mcb db complete with connections, testing and commissioning etc. as required.63 a 34 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 35 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required.group c 36 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 37 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 x 4 sq. mm + 1 x 4 sq. mm earth wire 38 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 39 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 40 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. 41 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 42 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (od 90 mm & id 76 mm nominal) 43 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal/dwc hdpe pipe as required.above 95 sq. mm and upto 185 sq. mm 44 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. 45 upto 35 sq. mm (clamped with 1mm thick saddle) 46 above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms flat clamp) 47 above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm ms flat clamp) 48 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm (clamped with 1mm thick saddle) 49 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 50 3½ x 95 sq. mm (45mm) 51 3½ x 150 sq. mm (50mm) 52 4 x 16 sq. mm (28mm) 53 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.225 mm width x 50 mm depth x 1.6 mm thickness 54 supplying and installing following size of perforated hot dipped galvanised iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.225 mm width x 50 mm depth x 1.6 mm thickness 55 supplying and installing following size of perforated hot dipped galvanised iron cable tray tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.225 mm width x 50 mm depth x 1.6 mm thickness 56 supplying and installing following size of perforated hot dipped galvanised iron cable tray cross member(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc as required.225 mm width x 50 mm depth x 1.6 mm thickness 57 providing, laying, testing & commissioning of b class heavy duty g.i. pipe conforming to is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm 58 supply of pvc/xlpe insulated and pvc sheathed / xlpe of 1.1 kv grade following type armoured power cable conforming to is 7098 part i complete as required. 59 4 core x 6 sqmm. copper conductor 60 4 core x 16 sqmm. aluminum conductor 61 3.5 core x 95 sqmm. aluminum conductor 62 3.5 core x 150 sqmm. aluminum conductor 63 supply and fixing of 450mm swep metal blade exhaust fan suitablefor operationon230 v,50 hz,singlephase,a.c supply in the existing opening including connections, testing, commissioning etc. as required 64 supply and fixing of 600mm swep metal blade metal body industrial wall fan suitable for 240v, 1 ph 50hz ac supply on wall including connections, testing, commissioning etc. complete as required. 65 supply installation testing commissioning of 4 ft long 36w surface mounting led batten 6500k, efficacy >100 lumen/watt, power factor =0.95 , ip20, cri =80, burning hours 50000 hours, 85% driver efficiency, thd=10% with 05 years warranty certificate from oem, made out of crca / extruded aluminum/pdc aluminum, mounting clamps, fixing arrangement, leds driver, complying with lm 80 & lm 79 etc. complete as required. 66 supply,installation,testingandcommissioningof80w led streel light 5700k, efficacy >110 lumen/watt, power factor=0.95 , ip65, cri=70, burning hours 50000 hours, 85% driver efficiency, thd=10% with 05 years warranty certificate from oem, made out of crca / extruded aluminum/ pdc aluminum, heat sink, mounting clamps, fixing arrangement, leds driver, surge protection system, cpmlying with lm 80 & lm 79 etc. complete as required. 67 supply and fixing wall mounting type gi metal bracket for streetlight including clamps, nuts, bolts, screws, making holes on wall etc. complete as required at suitable locations as directed by engineer in charge. 68 supplying, installation, testing and commissioning of electric driven positive suction pump consisting of following complete in all respects, as required :(a) horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal (b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation (c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) suitable cement concrete foundation duly plastered and with anti vibration pads (e) rain shed with enclosure for outdoor use (f) interconnection with suction and discharge pipe line with reducer, flanges, gasket, nuts, bolts etc.range: 30m 45m head range and 17 10 lps capacity 69 supply installation testing commissioning of star delta starter suitable for up to 12.5 hp pump motor set including drilling on wall, screws, nuts, bolts, connection with proper lugs etc. and ensuring successful operation of the pump motor set associated with the starter complete as required. 70 supply installation testing commissioning of 2hp 1 ph 230v 50hz dewatering submerssible pump including connection, discharge pipe line of minimum 6 mtr long of suitable size etc. complete as required.make: ksb, model: amaporter503 se or equivalent. 71 excavation of hard rock including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. 72 excavation of soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. ...

Sant Gadge Baba Amravati University - Maharashtra

35864354 hiring of electrical equipments, sound system arrangement, air conditioning & other works for the 39th convocation at sant gadge baba amravati university campus, amravati. 2 providing temporary illumination consisting of led tube light 4 x 20w or fluorescenttube light 4 x 36 / 40w, 230v, 50 hz having colour temp up to 6500k complete erected with mains and required switchgears with continuous earth wire erected and dismantled 3 ceiling fan with required down rod, wiring, earthing, switchgears etc. 4 providing temporary oscillating type pedestal fan 16 ( 400 mm ) or ceiling fan [ 1200 / 1400mm ] , 230v, 50hz connected with necessary mains, required switchgears with continuous earthing maintaining the same during the function and including dismantling. 5 providing temporary plug point with 3 pin 6a / 16a with necessary mains, required switchgears and continuous earth connection 6 air coolers ( symphony type ) with required wiring, earthing, switchgears, water filling and spraying khus perfume etc. 7 providing temporary evaporative air cooler ( fibre air desert cooler ) with 230v, 50 cycles, with 18 24 exhaust, minimum 40 to 80 litre water capacity tank connected with necessary mains, required switchgears with continuous earthing maintaining the same during the function and including dismantling. 8 providing and maintaining temporary 2.0 to 3.5 ton capacity tower type air conditioning unit complete with refrigerant r32 with temporary stand and fabrication work and required material to achieve cooling temperature connected along with necessary mains, required switchgears and continuous earthing maintaining the same during the function and including dismantling. 9 providing temporary xlpe / pvc armoured cable 4 core 95 sq mm aluminium conductor with continuous 10 swg g.i. earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary 10 tpn 100 amps switchgear with required wiring, scaffolding, earthing etc. 11 earthing cast iron plate type with required materials 12 hiring charges for supplying and maintaining temporary 415v, 50 cycles ac generating set 50 / 62.5 kva capacity with voltage regulation + / 5 %, and complete set enclosed in composite acoustic enclosure to restrict sound level up to 75 db at 1.0 m with necessary fuel, mains, switchgears and accessories complete with continuous running on load / no load as per requirements complete with self certification.note the above rates are with on load working of dg set up to 5 hours per day. for additional working hours exceeding average 5 hours per day cost of diesel shall be considered as per actual. 13 providing temporary illumination consisting of white / colour series lights with 8mm led miniature lamps of 2 to 3.4v [ 1000nos ] with cap with required switchgears erected and dismantled with rotor effect as approved up to three days. 14 providing temporary illumination consisting of led rope light having 4 to 6 w capacity per meter [ multi colour ] and consisting suitable power adaptor with mains, switchgears erected and dismantled and maintaining the same up to 3 days 15 providing and fixing temporary electronic rotating machine to give running effect to strips lights and miniature lights up to a load of 5000 w 230v, 50hz, complete with mains and required switchgears with continuous earth wire and dismantling up to three days. 16 providing temporary illumination consisting of water proof hmi par light upto , 400 w, 230v, 50hz, colour temp 6500k housing of pressure die cast aluminium alloy [ multi colour ] complete erected with mains, switchgears with continuous earth wire erected and dismantled up to three days 17 providing temporary illumination consisting of flood light fitting 200 w complete led fitting having colour temp up to 6500k, ip65, housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete required switchgear erected and dismantled. 18 ( b ) sound system 19 arrangement of high quality sound system for the dome & stageof size 220x80 feet is required. approx 3000 students & hon’ble governer, maharashtra, vvip dignitories, hon’ble m.p., hon’ble mla’s are expected to be present for this programme 20 audio mixer 16 channel & above as per requirement ( ahuja / studiomaster / alto / yamaha / phonic / bosch ) microphones of good quality and various types for e.g. condenser, collar, cordless handheld etc. microphones for speech and singing. 20 no’s & above as per requirement ( ahuja / studiomaster / akg / shure / bosch ) amplifiers with stand byarrangement. ( ahuja / studiomaker / alto / yamaha / phonic / boschmake ) a ) mosfet 3000 wattsb ) two zone – 1000 wattsc ) plain 500 wattsspeakers ( ahuja / peevey / phonic / sonodyne / bosch make ) a ) column b ) front 350 wc ) musical monitor ( dual speaker 350 watts ) d ) stage floor monitor 350 wattse ) horn – 40 wattsbattery operated system for stagea ) battery 12 v, 150 amps.b ) plain amplifier 250 wattc ) speakers 100 w.recordinga ) c.d. / d.v.d. player ( denon / sony ) b ) live program recorder with standby arrangement.c ) blank c.d. / d.v.d. / pen drive ( good quality ) d ) providing audio output / input to live telecast of programme with required type & length of cables....

Council Of Scientific And Industrial Research - Maharashtra

35582709 electrical renovation of director’s office & f & a project cell at iiird floor of main buildingat csir ncl. sitc oflight point / fan point / exhaust fan point with 2 x 1.5 sq.mm pvc insulated frls wires 1.1kv gradecopper conductorfinolex / polycab / rpg make in surface / recessed pvc conduit pipe / pvc casing capping asian / diamond / modi make & modular switches legrand myrius / mk blenz plus make with metal box & modular plate complete with connection & holder / ceiling rose anchor make.the modular boxes, plates & accessories should be of same make. also to run an earth wire of 1sqmm all along the length of the point. ( for general lighting indirectors office, project cell ) 2 wiring for circuit wiring with 2x2.5sqmm pvc insu.copper cond. frls wires finolex / polycab / rpg make, 1100v grade in surface / recessed pvcconduit pipe / pvc casing capping asian / diamond / modi make on surface / concealed including connections at both ends& to run pvc insucu earth wire of 2.5 sqmm green colour all along the length.rate is inclusive of all the material required for the job ( circuit mains for lighting ) 3 wiring for circuit wiring with 4x2.5sqmm pvc insu.copper cond. frls wires finolex / polycab / rpg make, 1100v grade in surface / recessed pvcconduit pipe / pvc casing capping asian / diamond / modi make on surface / concealed including connections at both ends& to run two runs ofpvc insucu earth wire of 2.5 sqmm green colour all along the length.rate is inclusive of all the material required for the job ( circuit mains for lighting ) 4 wiring for circuit wiring with 2 x4 sqmm pvc insu.copper cond. frls wires finolex / polycab / rpg make, 1100v grade in surface / recessed pvcconduit pipe / pvc casing capping asian / diamond / modi make on surface / concealed including connections at both ends& to run pvc insucu earth wire of 2.5 sqmm green colour all along the length.rate is inclusive of all the material required for the job ( circuit mains for power points ) 5 wiring for circuit wiring with 4 x4 sqmm pvc insu.copper cond. frls wires finolex / polycab / rpg make, 1100v grade in surface / recessed pvcconduit pipe / pvc casing capping asian / diamond / modi make on surface / concealed including connections at both ends& to run 2 runs of pvc insucu earth wire of 2.5 sqmm green colour all along the length.rate is inclusive of all the material required for the job ( circuit mains for power points ) 6 wiring for circuit wiring with 2x1.5sqmm pvc insu.copper cond. frls wires finolex / polycab / rpg make, 1100v grade in surface / recessed pvcconduit pipe / pvc casing capping asian / diamond / modi make on surface / concealed including connections at both ends for looping of lihght fittings.rate is inclusive of all the material required for the job ( looping oflight fittings ) 7 supplying & fixing 6amp 2 in 1 modular socket & 6a switch legrand myrius / mk blenz plus makeon wall in surface / recessed manner or on lighting control board recessed / surface complete with pvc box & modular plate. 8 supplying, fixing&connecting onwall in surface / recessed manner, switchboard with universal 6amp, 2 in 1 modular socket ( 2module ) 2no, &s.p. modular switch 6a 2no. legrand myrius / mkblenze plus make. rate is inclusive of pvc surface box & modular front plate. 9 supplying, fixing&connecting onsurface / recessed, switchboard in surface / recessed manner with , 6 amp, 2 in 1 modular socket universal 3no, &s.p. modular switch16a 1no. legrand arteor / mkblenz plus make.complete with modularfront plate & pvc box of appropriate size for surface mounting of switch board. switch board shouldberecessed or surface mounted on wall ( for computer ) . 10 supplying, fixing& connecting on ceiling prewiredled light fitting recess mounting typehavells make pluto neo panel 2x2 cat no.plutoneo02x2plr34wled840s, 34watts or equivalent of philips model no soft glow cat no.rc380b led36s 6500 g5 l60w60 psu od sg 9405 / wipro make complete complete with hanging support from ceiling & driver. the led light fiting should have minumum 3 years replacement warranty ( for lights above directrs table & secretariat & project cell ) 11 supplying, fixing& connecting recessed mounting led round down lighter fittinghavells make glow cat no.glowdlr10wled840s, 10watts or equivalent of philips make cat no.dn192b led10s 6500 psu wh s2 / wipro make complete with connections & driver. the led light fiting should have minumum 3 years replacement warranty ( false ceiling ) 12 supplying, fixing& connecting recessed mounting led square down lighter fitting, 10watts or equivalent of philips make cat no.dn096b led6s 6500 psu wh / havells make glow cat no.glowdlr10wled840s / wipro make complete with connections & driver. the led light fiting should have minumum 3 years replacement warranty ( false ceiling ) 13 supplying, fixing& connecting onceiling prewiredled strip philips make cat no. skycov 5m ww or equivalent of havells / wipro make with driver complete with driver of suitable wattage. 14 supplying, fixing& connecting on wall decorative light fitting philips / havells / wipro make. 15 supplying, fixing& connecting on ceiling prewiredled light fitting havells make cat no.plano surface, 36 watts, 4x1 or equivalent of philips cat no. smart bright surface cat no.sm270c led 30s 6500 psu wh / wipro make complete with suspension kit1.5 mtr, complete with driver.the fitting should be hung from the ceiling by using suspension kit fixed to the ceiling. ( project cell ) 16 supplying, fixing& connecting on ceiling / wall with prewired led tube light fitting with metal body havells make cat no. lumiline plus 24w / philips cat no. bn021c led 22s psu cw gr or wipro make, , 4 length complete with accessories.the led light should be in warm white colour / cool day light color as per the instructions of enginneer incharge. fitting should have minumum 3 years replacement warranty ( for false ceiling indirect light, washroom area ) 17 supplying & erecting ceiling fan with double ball bearings type with remote control, 26 28 watts, / usha make model no.heleous or equivalent of automberg / havells make.1200 mm sweepcomplete erected in position with necessary flexible copperwire leads of required colour with canopy & down rod of appropriate length as per site condition in length in provided hook / clamp with necessary rubber bushing, clamps, nuts & bolts, remote control etc. complete. 18 supplying & fixing exhaustfan gec / orientmake, light duty metal body, 225mm sweep in window complete with frame, brackets & louvers. ( for washroom ) 19 supplying & laying on wall / cable tray pvc armouredcable, 2 core x 4sqmm, polycab / gloster / asian make, copperconductor, 1.1kv grade at ncl site. ( before supplying cable, actual measurement at siteshould betakeninconsultationwith site engineer. ) the cable shouldbe fixed to the tray with m.s. screws. ( for acs ) ) 20 terminationof2 core, 4 sqmm copper conductor armouredcablewithsuitablesizeofcopper crimpingtype lugsintothe existing power db andotherend into load. the siemenstype cableglandshould be used for termination of cable 21 supplying & laying on wall / cable tray pvc armouredcable, 3.5 core x 35sqmm, polycab / gloster / asian make, aluminium conductor, 1.1kv grade at ncl site. ( before supplying cable, actual measurement at siteshould betakenin consultationwith site engineer. ) the cable shouldbe fixed to the tray with m.s. screws. ( for ac power supply ) 22 terminationof3.5 core, 35 sqmm akuminium conductor armouredcablewithsuitablesizeofaluminium crimpingtype lugsintothe existing power db andotherend into load. the siemenstype cableglandshould be used for termination of cable 23 supplying & laying i.s.i. make 25mm 2 mm thick rigid pvc conduit with isi mark ( embossed ) ( is:9537 part 3 ) heavy gauge ( hms ) with necessary bend, tees & junction boxes in wall or ceiling with u clamps & plastering with cement mortar & finishing the surface to match the background with continuous fish wire to draw mains laid in the same enclosure in an approved manner. ( fire detection system & network / communication system ) 24 supplying & fixing in concealed manner withmetal enclosure mcbdp 32 amp, c curve , 10ka legrand lexic / siemens / hager make on wall complete with connections & testing. 25 supplying & fixing in concealed manner with metal enclosure fpmcb 20 / 32 amp, legrand lexic / siemens / hager make on wall complete with connections & testing. 26 supplying & fixingmodular type telephone socket rj11 lergrand myrius / mk blenz plus make compete with concealed metal box & surface plate. 27 supplying & fixingmodular type network socket rj45 lergrand myrius / mk blenz plusmake compete with concealed metal box & surface plate. 28 supplying & laying in existing pvc conduit recessed / surface, pvc insulated telephone cable 2 pair 0.5 mm polycab makewith connections. 29 supplying & laying in provided concealed conduit pvc insulated cat 6 cable legrand / awaya / amp make. 30 supplying & drawing pvc insulated copper conductor armored frls cable 2 x 1.5sqmm in the existing / recessed conduit pipes of sizepolycab / finolex make 31 supply erection, testing and commissioning ofaddressable smoke detector withbase with binary coded address setting woring on 24v dc. dual led’s for 360° visibility.polarity free, sleek low profile housing design. regular 100mm base. ip rating : ip 42. approval:ul listed, make: ravel / honeywell / notifire 32 supply installation testing & commissioning of response indicators, conventional type for each smke detector installed above false ceiling to activate when the detector gives signal. the rinsponse indicators shall be mounted on false ceiling & visible from the floor level. 33 supply of conventional sounder cum strobewith 24v dc, audiable sound 85 db @ 1 mtr range ( 16 v dc ) . it is used for fire, burglar & emergency alarm system, low current consume @ 47 73 ma candela: flashing every second, 4 candela settings:15 / 30 / 75 / 110cd output and 2 different tone audiable sound. make: ravel or equivalen tof notifire / honeywell...

Mahanagar Telephone Nigam Limited - Maharashtra

35496891 tender for providing electrical installation and fans for ddg office sakivihar mtnl mumbai primary point wiring with modular switch:wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessedconduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. a ) surface / recessed pvc conduit 2 wiring for circuit / sub main wiring with following size of frls pvc insulated copper conductor 1.1 kv grade single core cable in surface / recess pvc conduit as per specifications etc. complete as required. 3 a ) 2x1.5 sq mm + 1x1.5 sq mm earth wire 4 b ) 4x1.5 sq mm + 1x1.5 sq mm earth wire 5 d ) 2x4 sq mm + 1x4 sq mm earth wire 6 e ) 4x4 sq mm + 2x4 sq mm earth wire 7 supplying & drawing following size frls pvc insulated copper conductor 1.1 kv grade single core cable in existing surface / recess ms conduit / pvc conduit / pvc casing capping / al. casing capping as per specifications etc. complete as reqd. 8 a ) 3x1.5 sq mm 9 b ) 3x4 sq mm 10 supplying and fixing of following size of medium class pvc conduit along with all accessories in surface / recess including cuttingthe wall and making good the same in case of recessed conduit as required. 11 c ) 20 mm dia pvc conduit 12 d ) 25 mm dia pvc conduit 13 supplying and fixing suitable size pvc box with modular plateand cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modularswitch, connections etc. as required. 14 supplying and fixing suitable size pvc box with modular plateand cover in front on surface or in recess, including providingand fixing 6 pin 5 / 6 a & 15 / 16 a modular socket outlet and15 / 16 a modular switch, connections etc. as required. 15 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a, tinned copperbusbar, commonneutrallink, earthbar, dinbarfor mounting mcbs ( but without mcbs and incomer ) as required.a ) 4 way tpn double door 16 s / f of 6a to 32a rating 240 / 415v , 10 ka, c curvemcbsuitable for inductiveload of following polesin the existing mcbdb complete withconnectionstesting and commissioningetc.as reqd. 17 a ) 6 to 32 amp sp 18 b ) 6 to 32 amp tp 19 c ) 63 a tpn mcb 20 supplying& laying of following size xlpe copper conductor armoured cable of 1.1 kv grade as per specification complete as reqd.a ) 4x6 sq mm 21 supplying & making end terminations with brass compression gland & heavy duty copper crimping lugs for following size xlpe armoured cable of 1.1 kv grade etc complete as reqd. a ) 4x6 sq mm 22 supplying decorative led box type fittings with blue coloured end cap pre wired for led tube and led tubular lamp including testing etc asrequired.make crompton / wipro / phillips / syska a ) 20 watts lt8 20 ( pc body ) &dmln1lt8 16or equivalent 23 supplying and fixingtwo module stepped type electronic fan regulator ( 100w ) on the existing modular plate switch box including connections but excluding modular plate etc. as required. 24 supplying of following size a / c single phase ceiling fan with all accessories i / c its connection with 1.5 sq mm flexible cu. wire from ceiling rose etc. complete as reqd. a ) 1200 mm sweep ceiling fan 5 star 25 s / f of call bell / buzzer suitable for 230 volt a / c supply i / c connection etc complete as reqd. a ) ding dong type type 26 supplying & fixing of fan hook with 10 mm dia. rod & 4 nos. anchor fasteners i / c clamp etc. complete as reqd. 27 s / l of following size of cu / gi bare earth wire along with the cables / conduits / panels for loop earthing i / c lugging, crimping as per specifications etc. complete as reqd. a ) 2.24 mm dia copper wire...

Airports Authority Of India - Maharashtra

35362968 bids are invited for entry exit announcer as per attached boq item no 1 , ceiling hung directional sign message 1 as per attached boq item no 2 , message 2 as per attached boq item no 3 , utility signs as per attached boq item no 4 , service areas as per attached boq item no 5 , circuit submain wiring alongwith earth wire as per attached boq item no 6 , circuit submain wiring alongwith earth wire as per attached boq item no 7 total quantity : 113...

District Collector - Maharashtra

35356328 supply of furniture , pendol , loudspeaker and other decoration material on rent basis 1 hire charges of office table of size 4 x 2 with table cloth 2 hire charges of plastic moulded chairs 3 hire charges of vip chairs without arms / with arms 4 hire charges of office table of size 4’ x 2 with table cloth & drover 5 hire charges of iron folding table 6 hire charges of cotton mattress with cover & pillow 7 hire charges of water drum 200 ltr. 8 hire charges of vip revolving chairs with arms 9 providing and erecting stage upto height 3.00 meter with top of necessary wooden plankssupported by frame on wooden ballies vertical / horizontal complete as directed by engineer incharge. 10 pvodinging and erecting shamiyana with 4” to 6” ballies with 10” centre of required height with proper shape etc. pendal as directed by engineer incharge with g.i. sheet on top or with tarpoline or ballies / bamboos frame with approved colour with celling. 11 providing and erecting carpet of approved colour ( green / red ) as directed by engineer incharge. 12 providing and erecting cloth railing, siding 13 hire charges of dari ( 12” x 15” ) 14 providing and erecting ramp upto height 3.00 meter with top of necessary wooden planks supported by frame on wooden ballies vertical / horizontal complete as directed by engineer incharge. 15 providing and erecting temporary strong wooden bracading with 4” x 5” diameter wooden ballies for vertical post 9 8’ centre with 3 number 3” to 4” wooden ballies fixed horizontally by bhampty or other string material including removding complete kaichi. 16 providing and recting temporary strong wooden barricading with 4” x 5” diameter wooden ballies for vertical post 8’ centre with 3 number 3” to 4” wooden ballies fixed horizontally by bhampty or other string material including removing complete kaichi. 17 providing and erecting temporary iron barricading horizontally with squatr mesh jail including removing complete. 18 providing and erecting sides of shamiyana & pendal with g.i. sheet 4” to 5” diameter wooden ballies / bamboos as directed by engineer incharge. 19 providing & fixing plywood of 6mm thick on hire basis including removing etc complete as directed by engineer in charges 20 providing & fixing plywood of 8mm thick on hire basis including removing etc complete as directed by engineer in charges 21 providing & fixing plywood of 12mm thick on hire basis including removing etc complete as directed by engineer in charges 22 hire charges of sofa set five seater with tea table 23 providing & fixing of terpoline on hire basis 24 providing and fixing new abc stored pressure type fire extinguisher of 5 kg capacity as per i.s. 13849 isi marked complete on rent basis. 25 air condition ( 2 ton capacity ) 26 hire charges for set of amlifier with matchening 4 mics with two speakers complete with installation & dismantaling ( 125 to 250 watts ) 27 hire charges for additional extra speakers wooden box type complete with installation testing maintaining dismantaling 28 providing oscillating type pedestal air circulator 600 / 900 mm or air cooler connected with necessary mains, switch gears with continuous earthing maintaining the same during the function & including dismantaling. 29 providing ceiling fan 1200 / 1400 mm with regulator and down rod connected with necessary mains, switchgears with continuous earthing maintaining the same during the function & including dismantling 30 rental charges for supplying & maintaining 440v, 50 cycles a.c. generating set 15 kva capacity with necessary fuel, mains switchgears and accessories complete with continuous running on load / no load as per requirements with mccb db with necessary certified. 31 rental charges for supplying & maintaining 440v, 50 cycles a.c. generating set 40 kva capacity with necessary fuel, mains switchgears and accessories complete with continuous running on load / no load as per requirements with mccb db with necessary certified. 32 rental charges for supplying & maintaining 440v, 50 cycles a.c. generating set 125 kva capacity with necessary fuel, mains switchgears and accessories complete with continuous running on load / no load as per requirements with mccb db with necessary certified. 33 temporary illumination consisting of tube light day light & colour 4 x 40 watts complete erected with tubes, mains and switchgears with condinuous earth wire erected and dismantled without using scaffolding 34 temporary illumination consisting of flood light fitting 1000 / 500 w complete halogen fitting with lamp, holders, mains and switchgears with continuous earth wire erected and dismantled without using scaffolding. 35 temporary illumination consisting of metal halide flood light fitting 400 w complete with lamp, holders, mains and switchgears with continuous earth wire erected and dismantled without using scaffolding. 36 providing temporary plug point with 3 pin 6a / 16a with necessary mains & switchgears & continuous earth connection for computer 37 providing temporary spike guard extension with 3 pin 6a / 16a with necessary mains & switchgears & continuous earth connection for computer 38 providing mini feeder pilar with one incomer and 4 outgoing of as directed by engineer incharge 39 supplying, installing, testing & commissioning of 1400 va digital pure sine wave inverter based on igbt technology single phase 230v, 50hz complete with 1 hr tubular battery backup on hire basis. 40 hire charges for cordless mics, hand mics complete with operating & maintaining along with required charged batteries etc complete...

Military Engineer Services - Maharashtra

34995386 tender for repair and maintenance of certain internal electrical fittings and fixtures of kwh meters, solar water heaters and repair / replacement of wall mounted lt dbs metering cubicals, submain wirings and other connected items at cme m & l for servicing solar water heater of 100 / 200 / 400 / 500 lpd capacity ( flat plate collector / tube collector ) by removing the flange plates, cleaning the collectors internally& externally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, recharging the water in recharge tank testing for satisfactory function all as specified and directed. 2 s & f heating element 25mm to 32mm dia, isi marked for solar water heating plant of capacity 3 kwall as specified and directed by engr in charge. 3 s & f flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all as specified and directed. 4 s & f thermostat for solar water heating plant of 100 / 200 / 400 / 500 lpd of suitable size and ratings etc complete all as specified and directed. 5 s & f flexible heat resistance rubber pipe ( from inter connect plate collector to hot water tank ) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified and directed. 6 m & l for repairs to storage type elect. water heater ( geyser ) of storage capacity 25 / 35 / 50 ltrs of any make comprisingof the following tasks at different locations as directed: ( a ) inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous compositionnot liable to impart test or otherwise contaminate the water. ( b ) replacement / repair of neon lamp / indicatorlamp. ( c ) replacement of the rubber / pvc gasket to ensure water tightness. ( d ) testing of geysers after repairs. 7 supply only thermostat complete with manually temperture settingknob extra long ( 11 inches ) isi marked suitable for geysers 25 litres to 50 litres capacity 8 s & f hot / cold water flexible hose pipe 12 / 16mm dia and 450 to 900mm long heavy duty covered with metal wires heat resistence with both ends pvc hexagonal check nut with washer to fixed on 15mm dia gi pipe all as specified and directed. 9 supply only heating element upto 2 kw as required at site including rubber washers ( isi marked ) completeall as specified and directed. 10 decarbonizing ofindoor mcb / meter boxany type removing unserviceable mcbs, burnt connecting wires, replacing burnt, damaged wires of any size, welding of hinges including welding using extra sheetsreplace burnt thimbles of existing size , dismantling the existing connected cables / wires and re connecting the same cables / wires complete all as specified and directedby engr in charge. note : ( i ) mcb will be measured & paid separately as supply only. ( ii ) necessary ms sheet and welding incuding sealing the meter with sealing lead / pvc seal all are inclusive of quoted rate. ( iii ) required size ofcopper cable for connecting mcbs and meters are including quoted rate. 11 labour only for attending arman complaints received through online media by deploying necessary skilled tradesman with helper as required at site on working hours from0830 hrs to 1730 hrs on all working daysat md accn area, cme kirkeenote: ( i ) the complaints will be entered in complaint slip by je e / m mcm. ( ii ) the complaint slip should be returned to je e / m on completion of the work with stores consumed. ( iii ) any delay in attending the complaints for more than 03 days, a penalty of rs 50 / per complaint will be adhered to the contractor. ( iv ) the details of stores consumed, complaint slip are to be produced during the rar bills. ( v ) t & p, minor spares like nuts, bolts, screws, washers insulation tape etc required for attending the complaints shall be provided by the contractor and the rate for the same is deemed to be included in the rate quoted. 12 m & l for repair and replace of unserviceable led driver suitable for 36 / 40 watt led panel light fitting 2 x 2 size on siteall as specified and directed by engr in charge. 13 taking down old conventional kwh meter deposited to mes store yard and supply & fix new tamper proof ac three phasestatic energy meter of accuracy class 1.0, 240 v, 50 hz with bakelite lcd display of rating 10 60 a, ( measures and display kwh , voltage, current, load, pf ) all as specified and directedby engr in charge. make: cat part nowm301bc7d10 of l&t or equivalent in hpl / benlo / schneider 14 taking down old conventional kwh meter deposited to mes store yard and supply & fix new tamper proof ac single phasestatic energy meter of accuracy class 1.0, 240 v, 50 hz with bakelite lcd display of rating 10 60 a, ( measures and display kwh , voltage, current, load, pf ) all as specified and directedby engr in charge. make: cat part nowm101bc7dl0 of l&t or equivalent in hpl / benlo / schneider 15 supply and replace, rubber yoke, ms clamps, bolts nuts with split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed by engr in charge. 16 m & l capacitor 2.5 mfd for ceiling fan all as specified and as directed by engr in charge. 17 m & l for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and as directed. 18 taking downof ceiling fandismantling blades from fan and deposited to mes store yard for repair and collect repaired / new ceiling from store and hangingthe same complete all as specified and directed by engr in charge. 19 m&l in replacement of pvc rectangular boards closed recessed of size 100 x 100 x 50mm complete all as specified and directed. 20 m&l in replacement of pvc rectangular boards closed recessed of size 175 x 100 x 50mm complete all as specified and directed. 21 m&l in replacement of pvc rectangular boards closed recessed of size 200 x 150 x 50mm complete all as specified and directed. 22 m&l in replacement of pvc rectangular boards closed recessed of size 250 x 200 x 50mm complete all as specified and directed. 23 m&l in replacement of hylam white 3 mm electrical switch board 24 m&l in replacement of led lamp 9 watt complete all as specified and directed. make : cat part no lhldeuebml8r009 of havells / bajajsyska 25 s&f in replacement recess cum surface panel round slim 18 watt 6500 k complete all as specified and directed.make: cat part no edgeproneorddlr18wled840s / crompton / bajaj 26 s & f mccb 4 pole 415v 63 amps 16 ka incl taking down old unserviceable one. 27 s & f mccb 4 pole 415v 125 amps 16 ka incl taking down old unserviceable one. 28 s & f mccb 4 pole 415v 160 amps 36 ka incl taking down old unserviceable one complete all as specified and directed. 29 s & f mccb 4 pole 415v 200 amps 36 ka incl taking down old unserviceable one complete all as specified and directed. 30 s & f mccb 4 pole 415v 250 amps 36 ka incl taking down old unserviceable one complete all as specified and directed. 31 s&f in replacement modular single phase motor starter for ac with green and red button complete all as specified and directed. make : cat part no msbe20 25 of benlo / havells / anchor 32 s&f in replacement modular 32 amps dp swtich without fuse complete all as specified and directed. make : cat part no psbedp20 25 of benlo / havells / anchor 33 taking down carefully copper / aluminium point wiring ( light, fan, bell, socket or power ) complete, including fixture and fittings such as switches, ceiling rose, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking creditand making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately. 34 m&l for point wiring with frlsh cable 1.5 sqmm pvc insulated ( red for phase and black for neutral ) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick pvc casing / capingwith all accessories and 1.50 sqmm green in colour pvc copper conductor cable for earth continuity connected to common earth dolly inclpvc box surface / flush type with pvc sheet for mounting fittings such as switches, sockets, fan regulators, etc complete all as specified and directed for one light / fan / bell point controlled by one switch & making goodto disturbed surface of wall etc for the following : 35 one light point controlled by one switch 36 one fan / exhaust fan point controlled by one switch and regulator 37 socket outlet, three pin 5 amps on the same board 38 socket outlet, three pin, 5 amp, independent 39 all as per item no.34 above, but with 2.5 sqmm cable and 2.5 sqmm for earth continuityfor multipin 15 amps socket outlet flush type on independent board. 40 material & labour forpoint wiring with 1.5 sq.mm nominal cross sectional area, single core, 1100 volts grade, multi stranded, frlshpvc insulated, unsheathed copper conductor cable in and including pvc concealed conduit of 20 mm dia or higher, medium grade complete with and including all pvc conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 sqmm nominal cross sectional area, single core, pvc insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings : 41 one light point controlled by one switch 42 one fan / exhaust fan point controlled by one switch and regulator 43 socket outlet, three pin 5 amps on the same board 44 socket outlet, three pin, 5 amp, independent 45 all as per item no.36 above, but with 2.5 sqmm cable and 2.5 sqmm for earth continuityfor multipin 15 amps socket outlet flush type on independent board. 46 s & f switch piano, flush type, single pole one way 5 amps complete all as specified and directed. 47 s & f switch piano, flush type, single pole one way15 ampscomplete all as specified and directed. 48 s & f bell pushflush type single pole one way 5 ampscomplete all as specified and directed. 49 s & fsocket outlet 2 in 1, 5 pin, 5 amps flush typecomplete all as specified and directed. 50 s & fsocket outlet 5 in 1, 5 pin, 15 amps flush typecomplete all as specified and directed. 51 s & f switch socket combination 5 in 1, 5 and 15 amp flush typecomplete all as specified and directed. 52 s & f ceiling rose, 3 terminal pvc / polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl pvc square blockcomplete all as specified and directed. 53 s & flamp holder, pvc / polycarbonate type with back plate suitable for batten fitting incl pvc square blockcomplete all as specified and directed. 54 s & f stepped type electronic fan regulator flush typeon the existing phenolic laminated sheetcomplete all as specified and directed. 55 s & f in replacemnet call bell ding dong ac, 230 volts, single polecomplete all as specified and directed. 56 s&f switch modular, one way 6 amps, 1 module with suitable plate and cover complete all as specified and directed. 57 s&fswitch modular one way 16 amps, 1 module with suitable plate and cover complete as per existing make and model all as specified and directed. 58 s&fsocket modular 6a, 2 / 3 pin combined 2 module with suitable plate and covercomplete as per exisisting make and model all as specified and directed. 59 s&f socket modular 6a / 16a, 2 / 3 pin combined 2 module with suitable plate and cover complete as per existing make and model all as specified and directed. 60 s&f modular fan regulator step type 120w, 2 module with suitable plate and cover complete as per existing make and model all as specified and directed. 61 s&f modular bell push 6 amps 1 module with suitable plate and cover complete as per existing make and model all as specified and directed. 62 s&fwhite cover plate with frame 1 module complete as per existing make and model all as specified and directed. 63 s&f white cover plate with frame 2 module complete as per existing make and model all as specified and directed. 64 s&f white cover plate with frame 3 modulecomplete as per existing make and model all as specified and directed. 65 s&f white cover plate with frame 4 module complete as per existing make and model all as specified and directed. 66 s&f white cover plate with frame 6 module complete as per existing make and model all as specified and directed. 67 s&f white cover plate with frame 8 module complete as per existing make and model all as specified and directed. 68 s&f decorative ultra slim with polycarbonate housing with high lumen output environmental friendly, energy efficient ready to use pack surface and wall mounted led batten ( led tube light fitting complete 20w ) with integrated electronic driver and 02 no pvc square blocks incl taking down old unsv fitting.make : cat part no lumilinebs20wled830spcwh of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar. 69 s&f decorative ultra slim with polycarbonate housing with high lumen output environmental friendly, energy efficient ready to use pack surface and wall mounted led batten ( led tube light fitting complete 10w ) with integrated electronic driver and 02 no pvc square blocks incl taking down old unsv fitting. make : cat part no lumilinebs10wled865spcwh of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 70 s&fnew generation energy saving led bulk head fitting 10 watt made up of poly carbonate housing with diffuser incl taking down old unsv fitting.make : cat part no hexaft10wled857ssymopc of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 71 s&f led building security light fitting 25 watt , energy saving and environmental friendly long life led fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with ip 66 protection including suitable size bracket incl taking down old unsv one. make : cat part no endurasundownsl25wled765pasybopcihd of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 72 s&f decorative wall light fittings ( bracket light ) , city 3 made up of polycarbonate suitable for 10 watt led lamp incl led lamp incl taking down old unsv one.make : cat part no lhdl06160099 of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 73 s&f in replacementip65 new generation, post top 35 watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power leds as light source.make : cat part no rubypt35wled830psymtopc of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 74 supply and fixing energy saving, environmental friendly, long life, exclusive innovative die cast aluminium flood light 30 watt with high power leds as light source, suitable for highlighting architectural features or area lighting. also suitable to rough services / installations. ( note the contractor is responsible to arrangesuitable height of ladder for replacement of fitting ) . make cat part no jetaquantoplusflp30wled757sylens of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 75 s&f enclosure, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amps, 240 volt incl taking down old unsv one. 76 s&f mcb distribution board double door spn 240 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable one. 77 s&f mcb distribution board double door240volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls incl taking down old unserviceable one. 78 s & f mcb sp 6 to 32 amps, 230 v ac incl taking down old unserviceable one complete all as specified and directed. 79 s & fmcb spn 40 amps, 230 v, ac incl taking down old unserviceable one complete all as specified and directed. 80 s & f mcb spn 63 amps, 230 v, ac incl taking down old unserviceable one complete all as specificed and directed. 81 s & fmcb tpn 63 amps, 415 v, ac incl taking down old unserviceable one complete all as specified and directed. 82 supplying and fixing in repairs 1100 volts grade heavy duty cable pvc insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of pvc tape and overall pvc sheathed in service connections one twin core cable flat or circular 83 supplying and fixing in repairs 1100 volts grade heavy duty cable pvc insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of pvc tape and overall pvc sheathed in service connections one twin core cable flat or circular 84 supplying and fixing in repairs 1100 volts grade heavy duty cable pvc insulated aluminium multistranded conductor of size 4 sqmm, served with inner sheathing of pvc tape and overall pvc sheathed in service connections one twin core cable flat or circular 85 s&f led panel 2 feet x 2 feet size 36 wattt glare free symmetrical including driver and taking down old unsv one complete all as specified and directed.make : cat part no venusneohe4x1plr36wled857s of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker. 86 supply and fix in repairs mushroom ( prismatic ) decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit led lamp b22 base. make : cat part no lhfxamn1tn6f035 of havells or equivalent of philips / bajaj / crompton greaves / wipro / shakti / halonix / jaquar / c & s / bentec india ltd. / luker.. 87 supply, install in replacement metering cubical board wall mounted self supporting compartmentalised design of suitable size cpri approved to accommodate the lt switch gears & other accessories suitable for 415 volt 3 phase 4 wire supply made out of 2.0mm crca sheet powder coated having gasketed front two hinged doors with locking arrangement including having provision for glass / fibre section with rubber gasket to watch meters reading without opening the panel door including bottom and top detachable gland plate complete with suitable size of rust proof nuts bolts and washers etc complete with mounting accessories including the following : 88 four aluminumbus bar 200a mounted on epoxy insulators provided with rust proof nuts bolts and washer. 89 mccb 4 pole 63 amps 25 ka 1 no. 90 mcb spn 32 amps 04 nos 91 mcb sp 6 32 amps 01 no 92 space for mounting of tamper proof electric meter 0 60 amps 04 nos. 93 led indicating lamp 3 nos ( ryb ) 94 ammeter 0 200 amps with ct coil and selector switch 01 set 95 voltmeter 0 500volt with selector swtich 01 no. 96 note: rates for taking down and refixing of energy meters deemed to be included in the quoted rate. rates for other minor accessories such as nut, bolts, removing and jointing of cable with lugs etc shall be included in the quoted rate of this item. 97 material & labour for replacement of old unsv mccb of any type / capacity with new mccb fp 400 amps 415 ac, 50 hz, 50 ka thermal magnetic release adjustable type complete all as directed. make : indoasian / l&t / legrand 98 m & l for preparation of old painted surfaces of lt panel or street light panel / metering cubicalscovered by dust and other depositedmaterials by cleaning frompanelof sizeincluding repair of panel door, hinged nutbolts, clamp etc and painting with one coat of synthetic enamel paint of existing colour complete all as specified and directed.note :size of panel may be differ no extra shall be paid for painting of extra size panel as specified in item. 99 supply and fixing in replacement three pole contactor current rating 70 a general use 10a, 415vwith coil make l&t model mnx 70 three pole contactor complete. make l&t cat part no cs97076 / legrand / schneider 100 supply and fixing in replacement mnx 50 to 80 spare coil for three pole contactor complete all as specidired and directed.make : l&t cat part no cs96318 / legrand / scheider 101 supply and fixing in replacementdigital timer switch with inbuilt backup current capacity 16 amps operated on 415 volts ac 50hz complete all as specified and directed. make: indoasian cat part no. tda43111 / legrand 102 supply and fixing in replacementexisting aluminiumbus barrectangular 200 to 400 amps full for phase and half for neutral and interconnection of mccbs to bus bar mounted on epoxy insulators including nut, bolts with colour coding pvc sleeves. note : size of bus bar should be as per existing or as directed by engr in charge. 103 supply and fixing in replacement of aluminiumlugs of size 16 sqmm to 50 sqmm and tightening of all connecting points, cable connection complete all as specified and directed. 104 supply and fixing in replacement of aluminiumlugs of size 70 sqmm to 120 sqmm and tightening of all connecting points, cable connection complete all as specified and directed by engineer in charge 105 m&l for sub main wiring with two run of10 sqmm single core multi stranded pvc insulated and unsheathed copper conductor ( red for phase and black for neutral ) of grade 1100 volt frlsh cable in and including 1100 volt electrical grade pvc conduitof desired colour not less than1.2 mm thick and 25 mm wide& 10 sqmm copper conductor cable pvc unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. 106 all as per item no.88 above, but size 10 sqmm four runs andwith one run 10 sqmm frlsh copper wire for earth continuity. 107 all as per item no.88 above, but size 6 sqmm four runs andwith one run 6.0 sqmm frlsh copper wire for earth continuity. 108 all as per item no.88 above, but size 6 sqmm two runs andwith one run 6.0 sqmm frlsh copper wire for earth continuity. 109 all as per item no.88 above, but size 4 sqmm four runs andwith one run 4.0 sqmm frlsh copper wire for earth continuity. 110 all as per item no.88 above, but size 4 sqmm two runs andwith one run 4.0 sqmm frlsh copper wire for earth continuity. 111 all as per item no.88 above, but size 2.5 sqmm two runs andwith one run 2.5 sqmm frlsh copper wire for earth continuity. 112 m&l in replacement maintenance free grounding solution set earthing comprising of earthing rod, outer pipe in gi and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. gi terminal size of 100 x 50 x 6mm with 2 nos m8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. electrode must be tested for short circuit test of minimum 40 ka at cpri / nabl. the earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 mtr. the bore drilling will be donewith the help of pneumatic boring machine, 50 kgs bfc will be placed in the bore to cover the earthing rod from all sides. bfc will be poured in slurry form in properly mixed condition. the earth pit cover square 300 x 300 x 240 mm to be provided to cover the earth pit and shall be made of reinforced frp and should be capable of carrying the weight of 5 tons. make : u protecearthing / shivangi engineering works ( earth sol 3 ) / jef techno solution pvt ltd ( jef ecosafe ) 113 note : ( a ) rates of boring 3.5 mtr for earth electrode, gi strip 20 x 3 mm & 40 mm dia protection pipe upto 7.5 mtr from earth electrode is deemed to be included in the quoted rate. ( b ) on testing, after completion, if the earth resistance <2 ohms is not obtained, earthing will be done again at no extra cost till the desired earth resistance is obtained. ( c ) test certificate from the oem has to be produced by the contractor for the material used in earthing. 114 s&f mcb distribution board double door spn 240 volts 12 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incltaking down old unserviceable one. 115 m & lmcb distribution board double door 415 volt, tpn4 way, incl taking down old unserviceable 116 s&f load line vertical tpn distribution board 4 way including 1 incommer mccb of 125 amps 4 pole double door ip 43 protection, powder coated, ik08 with provision of suitable size bus bar and cable management kit complete including taking down old unserviceable one all as specified and directed. 117 supply, laying and testing cable xlpe insulated screened pvc bedded galvanised steel strip or wire armoured, electric power cables ( heavy duty ) with stranded aluminium conductor 1100 volts grade in trenches / passing through pipe / fixing on walls, floors etc incl using suitable clamp of cross sectional area4 core 25 sqmmin and including taking out old one all as specified and directed. 118 all as per item no.99 above, but 3.5 core 35 sqmm 119 excavation in trenches not exc. 1.5m wide and not exc. 1.5m deepand making goodsurface for laying / removing of cable all as specified and directed by engr in charge as in 120 soft / loose soil 121 hard / dense soil 122 returning, filling in, excavated soil in trenches, including watering and well ramming in layers not exc. 25 cm complete all as specified and directed. 123 removal of surplus excavated spoil to distance not exc. 50metre and deposting where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. 124 supply & laying in replacement of telerex dwc ( double wall corrugated ) hdpe pipe isi marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cableincl couplers & bends complete all as specified and directed....

Rural Development Department - Maharashtra

34631547 supplying and erecting led flood light fitting of 120w, including lamp, with pf 0.95, class ip 65 and above class ip 65 and above housing of pressure die cast alluminium alloy and heat sink extruded alluminium complete per specification no fg odf ( 2 5 16 ) , supplying, erecting & marking spmcb ga to 32a, b series ( for ghting ) in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230v / 10a with 10 hrs , supplying, erecting & terminating pvc armoured cable 2 core 10 sq mm aluminium conductor with continuous 5.48 sq mm ( 12 swg ) g.1. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specificat ( 7 1 6 ) , gst...

Reserve Bank Of India - Maharashtra

34315574 dismantling carefully removing all distribution boards, fans, light fittings, decorative lights, geysers, water purifier, wires, conduits, casing capping switch boards, telephone sets etc. provided in the flat and keeping reusable items in safe place as instructed / directed by bank?s engineer. 2 2 sitc of mcb db supply, installation testing and commissioning of single phase 12 way mcb d.b. metallic double door ( factory fabricated ) , in concealed manner of approved make, all termination of wires with lugs with crimping etc incomer 40 amp dp rccb ( 100 ma ) 1 no. outgoing 20 amp sp mcb 5 no. 10 amp sp mcb 5 no. blank plates as required, mcbs with 10 ka breaking capacity & c curves, with all accessories and interconnections as instructed by bank?s engineer. 3 3 wiring for light point supply, laying, installation, testing & commissioning wiring for light points using three runs of 1.5 sq mm, 1100 volt grade fire resistant low smoke ( frls ) pvc insulated stranded copper conductor wire ( neutral, and earth in looping system ) to respective point outlet ( inclusive of circuit wiring using three runs of 2.5 sq mm 1100 volts grade stranded copper conductor pvc insulated fire resistant low smoke frls wire from mcb db to respective switchboard ) partly in surface with heavy duty required size of casing , capping for ceiling , beam points & partly in rigid heavy duty pvc conduit of required size with all accessories, to be laid in concealed manner after a chase made in wall including mending good the damages as original finish manner with all accessories please refer to part 1 of the tender document. 4 4 wiring for ceiling fan point same as item no. 03 above, but for ceiling fan point along with supply and fixing of electronic 5 step 120 w type fan regulators as approved by banks engineer, socket type with speed marks, modular type of approved make with 10 amp modular switch as specified in item no 03 and complete with interconnection etc 5 5 wiring for 10 amp plug point independent wiring for independent 10 amps plug point with 3 x 2.5 sq mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no.03 above, along with 10 amp modular switch, and shutter type socket ( 2 pin+ 3 pin ) mounted separately on suitable size heavy duty gi box for concealed. these 10 amps points are to be extended from main switch boards provided in respective room as directed by banks engineer 6 6 wiring for half point on control switch board same as item no. 03 above, but for supply, fixing providing ( half point ) wiring for 10 amp. universal socket ( 2 pin + 3 pin ) and switch modular type to be fixed on same switch board used for light / fan / plug point. 7 7 wiring for computer point same as item no.03 with 3x2.5 sq.mm multi stranded copper conductor frls wire for phase, neutral and earth pvc insulated 1100 grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner but for computer point consisting of 3 no.s 10a 3 / 5 pin socket controlled by 3 no 10a modular switch fixed with suitable size heavy duty gi box for concealed with pvc board for surface as specified in item no.03 above. a separate conduit to be taken from mcb db with separate earth wire. 8 8 wiring for call bell point wiring for bell point as per item no 03 above, but with 10 amp modular bell push to be fixed in concealed manner with control off switch on switchboard provided in the flat along with supply and fixing of ding dong bell of approved make with hardware materials, as approved by banks engineer. 9 9 wiring for 2 switch 2 socket point for tv same as item no.5 above but for 10 amps 3 pin modular sockets 2 nos. controlled by 10 amps modular switches 2 nos. 10 10 wiring for 20 amp plug point ? independent wiring for independent 20 amps plug point with 2.5 sq. mm x 3 runs multi stranded copper conductor frls wire ( from mcbdb to plug point ) for phase, neutral and earth pvc insulated 1100 volts grade in rigid pvc conduit of approved size along with accessories to be laid in concealed manner as specified in item no 03 above, along with 20 amp modular switch, and shutter type 10 / 20 socket mounted separately on suitable size heavy duty gi box concealed with pvc board on surface along with covers of approved. 11 11 telephone wiring wiring for 03 nos. telephone sockets rj 11 outlet with shutter as per item no. 03 using two pair 0.5 mm dia tinned copper pvc insulated wire from common point in staircase to drawing cum dining room of individual flat and further looping to another point ( each bedroom ) , separate conduit to be laid for tel / cable tv wires, using all accessories as per item no. 03 ( separate conduit is to be laid up to common point in staircase ) as directed by bank?s engineer rate includes supply, laying, terminating etc. of telephone socket and wire, complete in all respect. ? drawing room: 01 nos. socket ? bedroom 1: 01 nos socket ? bedroom 2: 01 nos socket 12 12 cable tv wiring wiring for cable tv point with rj6 cable tv wire laying from cable tv operator junction box installed in the staircase up to first point in the drawing room making the parallel connection in the bed room gi with same wire rj6 cable tv wire along with modular type tv socket all in concealed manner ? drawing room: 01 nos. ? bedroom 1: 01 nos ? bedroom 2: 01 nos 13 13 ceiling fans supply, installation, testing and commissioning of 1200 mm, 3 blade new ceiling fan with all necessary mounting accessories. hall bedroom 1, bedroom 2 14 14 ceiling fans supply, installation, testing and commissioning of 600 mm, 4 blade new ceiling fan with all necessary mounting accessories. kitchen 15 15 tube light fittings supply, installation, testing and commissioning of tube light fixtures 20 / 22 w led tube light using 2 core flexible 0.5 sq mm. flat pvc insulated white copper wire with adaptor complete with all accessories, to be mounted on pvc square block as per instructions of bank?s engineer. 16 16 exhaust fan supply, fixing , testing & installation of approved make? 250 mm dia high speed exhaust fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in kitchen as per site condition complete in all respect. 17 17 exhaust fan supply, fixing , testing & installation of orient / crompton make? 200 mm dia high speed fresh air fan with pvc enclosure & accessories, rate shall include necessary window modification if required suitable to install new fan in wc as per site condition complete in all respect. toilet and bathroom 18 18 rebate item rebate for taking away all unusable items like wires / switches / switchboards / db?s removed under item no 01 ( per flat ) 19 19 cgst cgst amount per flat 20 20 sgst sgst amount per flat...

Tata Memorial Centre - Maharashtra

34260320 computational biology centre and cross talk lab on turnkey basis at actrec engineering, procurement supply, installation, testing and commissioning of computational biology centre and cross talk lab on turnkey basis at actrec , part – a: core infrastructure , civil , demolishing existing brick masonry with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry / rcc structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises and scope also include dismantling and careful removal of doors, distribution panel and storing and stacking complete all as directed by the engineer in charge. ( existing toilets, guard room & record room & ground floor & all areas wherever required for hpc facility ) , dismantling of wash basin and removing of wall tiles and all the allied stonework and pipes & fittings wherever necessary and disposal of unserviceable material carting away the debris out of hospital premises or handing over the same to engineer in charge , flooring breaking: dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandoor stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material and disposing unserviceable material out of hospital premises as directed by the engineer in charge. , dismantling and removal of complete fire fighting system and handing over all the material ( without any damage ) anywhere within the campus as per the instructions of engineer in charge. this includes plant, machinery, equipment for cutting, welding and dismantling complete material safely. , demolishing cement concrete and bitumen road / kerb stone manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. , providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle size 600mm center to center, lock and stopper etc. included in the item rate ) . anyquality approved by engineer incharge based on sample. , providing and fixing of hollow metal un insulated fire rated doorsas per is 3614 part 1, for stability and integrity. pressed galvanized steel confirming to is 277 with the following specification. recommended fire door shall be tested to is 3614 part 2 / iso 834 1 part 1 / bs476 part 20 & 22, cbri / certifire or third party certified or equivavelent lab, for maximum rating of 120mins, .labeled doors with certification shall be with vision glass as a part of complete assembly. deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. proper label confirming the type of door and the hourly rating is mandatory. door frame shall be single rebate grooved profile of size125 x 60mm made out of 1.60mm ( 16gauge ) minimum thick galvanized steel sheet. frames shall be mitered and field assembled with self tabs.door frames should be prepared for suitable hardware and should have necessary reinforcement to withstand regular wear and tear.frames to have inbuild grooved sealing system and shall be site fitted with fire rated epdm gasket as standard. all provision should be mortised, drilled and tapped for receiving appropriate hardware. door leaf shall be 46mm thick fully flush double skin door, un insulated with vision lite. door leaf shall be manufactured from 1.2mm ( 18guage ) minimum thick galvanised steel sheet. the internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. the edges should be interlocked with a bending radius of 1.4mm. for pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. the glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.all doors and frames shall be finished powder coated and shall have passed minimum 500 hours of salt sprey test. rate shall include supply and installation of door and hardware as a complete assembly including door closure, hinges etc..all doors shall be provided with stainless steel hinges with concealed door closures of required capacity and rating. provision of access control interlock and wiring shall be made in all door shutters and frames with requisite hardware. rate excludes installation of panic bar. , supply and fixing of slim glass partition of 12mm toughened glass using system 45 frames to a height of maximum 3m or as per drawing.the fixed glass to be fixed usingbp45 profiles at top & bottom &sp45 at sides ( the profile is for reference ) . the profile size to be 45x25mm to be fixed on to the floor / wall / ceiling as per the architect design.h junction profile to be used at all glass to glass vertical joints, 90 deg l junction profiles and t junction profiles necessary as per design.in case of glass overall panel mp45 & bp45 overpanel profile to be used.in case of open glass edges ep45 end profile to be used. the alexa profiles shall be suitable for glass thickness of 10 / 12 / 13.52mm.the profile shall be 20 micron matt natural anodized, the profile manufacturer to supply all the necessary clips, seals and fixing accessories for the system. all profiles to be with 2 mm gauge thickness including 20 micron of anodizing. , supply & installation of 2 hrs fire resistance rated fm approved sandwiched wall panels with 0.80 mm skin thickness with overall thickness of 150mm and with 98 + 2kg / cu.m density of rockwool insulation. both sides gi powder coated sheet as per clients approved shade along with flashing and with water resistant silicon sealant at required area and providing necessary accessories for fixing of metal partitions as per drawings with gi profile for reinforcement. ( inclusive of bottom track / interlock sections / silicon ) ( certificate for fire rating to be provided ) . vision glass on all sides for direct observation of hpc from outside should be compatible with partition and in fire rating and with maximum dimension of 1m*1m. with porcelain finish having rewritable capabilites and printing work to be done wherever required as per the instruction of engineer in charge. one side measurement will be taken. anyquality approved by engineer incharge based on sample. , supply & installation of 2 hrs fire resistance rated fm approved sandwiched wall panels with 0.80 mm skin thickness with overall thickness of 50mm and with 98 + 2kg / cu.m density of rockwool insulation or 40+ 2kg / cum puf insulation . both sides gi powder coated sheet as per clients approved shade along with flashing and with water resistant silicon sealant at required area and providing necessary accessories for fixing of metal partitions as per drawings with gi profile for reinforcement. ( certificate for fire rating to be provided ) as per the instruction of engineer in charge. one side measurement will be taken. , supply & installation of 80mm thick sliding folding partition with aluminium frame, track and trolley and 1mm thick hard pressed laminate finish of approved shade on both sides in the middle of conference room including all the hardware, accessories and rotating and retracting mechanism required as per the instruction of engineer in charge complete. one side measurement will be taken. , toughened lacquered glass panelling: providing and fixing of 6mm thick toughened glass ( premium griha rated lacquered glass from glass manufacturer ) of approved colour by doit&c, mounted on clip ( j / j1 / i type ) or equivalent on a perfectly levelled surface ( 12mm thick water proof marine plywood / acc blockwork / aluminium channel / bare rcc wall surface ) . lacquered strong glass must be made industrially ( via curtain coating process ) ; opaque ( if viewed against a support wall ) , coated with pu lacquer ( 100 micron thick ) ; colour consistency ( measured by spectrophotometer cm5081 ) ; highly durable ( passes persoz hardness test for minimum 220 oscillations ) ; humid resistant ( conforms to bs en 1036 1999 ) ; environmentally friendly ( no lead, no arsenic, no copper, no formaldehyde ) ; appropriate recycled content ( 12% post industrial / 6% post consumer ) ; compressive strength ( 1000 mpa ) & tensile strength ( 40 mpa ) , same as float glass. tempering should be done as the en 12150. glasses are to be fixed with polymer clips ( single sided j1 & j2 type, double sided i type ) , white backing foam and grey impact absorbing foam; to accommodate upto ± 10mm substrate undulation, and with a horizontal load capacity of 30kg / 100mm and vertical pullout load > 200kg / 100mm, glass should be supported with 1mm thick lip covering upto 3mm of glass surface; clips should be fixed using durable, non corrosive, strong s.s.screw 45mm long. all wooden material to be used shall be anti termite treated. the measurement only for the portion covered by glass to be considered. , providing and fixing fabric backing commercial grade wall paper of approved shade with recommended adhesive of approved quality which have 100% washable, scratch resistance, peel proof, and fire retardant properties. the wall paper should give a seamless finish. including cost of preparation on the base surface for fixing the wall paper as per the manufacturer specification, complete in all respect as per direction of eic. , supply & installation of 80mm thick insulated metal partition cladded with fabric and insulated with glasswool / rockwool for sound insulation. the partition should have provision for modular electrical and plumbing fittings as per the site conditions. skin thickness 0.6 to 0.8mm. finish : powder coated. face of partition : interior face: g 90 galvanized or az 50 aluminum zinc coated steel in 26, 24 and 22 ga. , supply & installation of 80mm thick insulated metal partition cladded with fabric ( towards conference room ) , on the other side clad with marine mdf. insulated with glasswool / rockwool for sound insulation. the partition should have provision for modular electrical and plumbing fittings as per the site conditions. skin thickness 0.6 to 0.8mm. finish : powder coated. face of partition : interior face: g 90 galvanized or az 50 aluminum zinc coated steel in 26, 24 and 22 ga. , providing and fixing flush doors 35mm thick with 1.0 mm laminates on both sides. the item includes teakwood chaukhat ( frame ) made from 75x50 teakwood. the door to have 12mm teak wood lipping on edges. the door is to be complete with cylindrical door lock , 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. , providing&fixing 50mm thick bwpgradesingle leaf flushdoorofsize ( 1200 x2400 ) includingteakwood lippingpatti12x55mmtoachieveexposedperiphery section of flush door finished with4mmthick veneer outside & inside 1 mm thick laminate with suitable mounting door frame as required. allwood& veneer surfaces shall be finished with melamine polish as per approvedtint includingmoulding, nails, screws, fevicol including necessary scaffolding & cleaning as per architects detailed drawing & design etc. complete. the door is to be complete with cylindrical door lock, 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. ( d1 ) , providing and fixing panic bar / latch ( double point ) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the engineer in charge, all complete. , providing and constructingaac light weight block masonry with 75mm / 100mm / 150mm / 200mm / 300mm thick at all levels in by using approved block laying polymer modified adhesive mortar, including 75mm thick patli / stiffeners of m 15 gradeat every 1000mm with 2 nos 8mm steel bars all to be considered in the cost and no separate measurement will be done for steel and patli, also including scaffolding, racking out joints, curing with curing compound etc. in line, level and plumb, all complete as per specification for all height of floor or as directed etc. ( rate includes the cost of stiffeners hoop ) . ( no holes for scaffolding will be permitted into the blockwork ) , grproc plaster : providing andapplying 1stqualitygyprocplaster ( gyproc elite 90 ) including bonding coat of gyproc bondwith minimum 10 12mm thickness to internal brick / block / concrete walls at all position in proper line, level and plumb including scaffolding, cleaning, hackingofconcretesurface, removing debris out of site etc. complete. as directed to achieve perfect line level and plumb. , providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. , providing and applyingacrylic ( premium ) emulsion paint of approved qualityandshadeonwallswithsand papering& cleaning the surface, applying one coat of primer and lambi / puttytofullsurface3times, thereafterpaintingthe surfaceintwo coatsoverbaseprimercoattoachieveeven finish. rate is inclusive of all double scaffolding, all material and cleaning as per manufactures standard application method & specification etc. complete. , providing and fixing artificial grass with recommended adhesive of approved quality which have 100% washable, peel proof, and fire retardant properties. the grass should give a seamless finish. including cost of preparation on the base surface for fixing the grassas per the manufacturer specification, complete in all respect as per direction of eic. , providing and installing of 8mm thk brick claddingas per the manufacturer specification in approved pattern with backing coat of 1:4 cement plaster and neatcementfloatusingpolymerbasedtileadhesivesof approved quality including filling joints, complete in all respect as per direction of eic. , providing and laying 600 x 600 vitrified tiles as specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirting ofanapproved, quality, and pattern / design for flooring including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge.as per manufacturers specifications. , providing and laying 800 x 800 vitrified tiles as specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirting ofanapproved, quality, and pattern / design for flooring including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge.as per manufacturers specifications. , providing and layingoutdoorvitrifiedtiles600mmx600mmas specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooring and skirtingofanapproved, quality, and pattern / design for flooring and skirtingincluding cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge. , providing and layinglapato finish vitrified tiles 600mm x 600mmas specifiedbelowconformingtoi.s.15622 2006withwater absorptionlessthan0.08%forflooringand skirting ofanapproved, ` and pattern / design for flooring and skirting including cementmortarbeddingof25mmthickin1:4proportion, cutting, levelling, jointing, fillingthejointsby app colour , curing, finishing etc. complete as directed by engineer in charge. , providing and fixing 1st quality antiskidceramic floortile size 300x300 mm or more ( thickness to be specified by the manufacturer ) for flooring and skirting confirming to is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete ( including the cost of cement mortar bed 1:4 ) . , providing and laying machine cut, mirror polished approved coloured granite slab of any approved size 20 + / 2mm thick for flooring in required pattern with approved coloured granite inlay work on a bed of 1:4 cement mortar including neat cement float, filling joints with neat coloured cement slurry, to match the colour of granite, curing, polishing and cleaning complete. , providing and laying machine cut, mirror polished marble stone flooring and skirting, in required design ( simple geometrical, abstract etc. ) and in patterns in combination with italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with white cement slurry @ 4.4 kg / sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge. in combination with 18 mm thick italian marble stone slab, perlato, rosso verona, fire red or dark emperadore etc is to be included. , providing and fixing machine made synthetic carpet having total carpet weight more than 550 gm / sqm. and more than 5mm thickness superior quality complete in all respect as per direction of engineer in charge. ( euronics or equivalent quality preapproved by engineer incharge ) , providing and laying machine cut, river finish graniteof anyapprovedsize20+ / 2mm thick for flooringin required patternwithapprovedcolouredgraniteona 20mm thick bedof1:4 cement mortar including neat cement float, filling joints with neatcolouredcementslurry, tomatchthe colourof granite, curing, polishingandcleaningcomplete. , providing & laying ofimported engineered wooden flooringofsize 215 mm width xlength 2200 mm x 20 25 mm thick ( as per manufacturers specifications ) , asperiso24346 ( en428 ) texture&design, top wear layer thickness 3.5 mm, with 3 mm under lay of foam with a direct laminated surface treated with aluminium oxide on top ofa high density fibre board with a density of 850 kg. / per mtr. having a click system tongue and groove joint to secure a long lasting joint. the planks are to be termite resistant and water protected with both side lamination, withpremiumfinish plank, glue freelocking system;2lock, with maximum floor surfacetemperature 27 c, with self –regulating under float heat system, with formaldehyde emission e1 as per en 13986, reaction to fire dfl as per en 13501 and100% recyclable with mini or maxi bevel lengthwise etc. complete. ( offices & conference room ) , kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) , providing & fixing 12mm thick x 100 mm highfirst quality solid teakwoodskirtingwherever necessary including melamine polish shade to be match with the same matching shadeofwoodenflooring &withveneershadetoallwood surfaceswith 6mm groove between skirting & gyp / veneer to t.w.frameworkort.w.panellingasperarchitectsdetail drawing & design etc. complete. , providingandfixingmachinecutmirrorpolishedblue pearlgranitestoneslabofrequiredsizeand20mm thick of approved quality , vein and colour for dado fixed on base plaster on 20mm thick cement mortar 1:4 including filling joint with neatcolouredcementslurry, curing, handpolishing, moulding, edgefinishing, andcleaningetc.complete. , providing&fixingvitrifiedtilesfortoiletdado of size 600x600 as per manufacturers specificationanyothersuitablesize approvedby architect andofapprovedcolourandshade finished, in approved pattern with 12mm thick backing coat of 1:4 cement plaster / mortar and neatcementfloatusingpolymerbasedtileadhesivesof approved quality including filling jointsto match the colour of dado curing, acid cleaning etc. complete. for toilet , italian marble cladding providing and fixing machine cut and mirror polished approved coloured italian marbleslabwithinlaysofapprovedsize, 20mm+2mm thk. of approved quality for required pattern on a bed of 1:4 cm25mmaveragethicknessincludingneatcement float, filling joints with neat coloured pigment , curing, polishingandcleaning, highglosstinoxidepolishwith italianpolishmachineetc. complete. , providingand constructinggranite kitchen platformwith fixing of quartz sink 600 mm x 450 mm size as per detailed drawing includingverticalbothsidepolishedgranite stone 19 to 22 mm thick double supports with kadappah base 35 to 40 mm thick and polished granite19 to 22mm ontop with side strips of granite at front and both sides of platform raised with two vertical granite supportsincluding cutting, opening asperarchitectsdetailsdrawing anddesign asdirectedby engineer in charge. for sink of required size in graniteetc. complete. ( rateexcludesquartzsink but includes rate for kadappah ) .only total surface ( plan ) area of platform to be measured , supply of quartz sink 600mm x 450 mm size including fixing the sink in position with waste coupling, bottle trap and any other fixtures all complete as per the specifications and directed by engineer in charge. , providing & fixing single piece rimless bowl for coupled wc with uf soft close slim seat cover, hinges, fixing accessories and accessories set, size : 380x660x850 mm, s trap 250 mm. as per approved sample. , providing & fixing soap dispenser metallic bottle. as per approved sample. , p&f soap dish holder.as per approved sample. , providing & fixing toilet paper holder with flap recessed type ( stainless steel ) . , p&f stainless steel surface mounted sanitary napkin disposal ( with flap ) of approved quality / quality. cabinet 18 8, type 304, stainless steel size 270mm ( l ) x 105mm ( w ) x 385mm ( d ) capacity: 4.6 litres equipped with full length stainless steel piano flap. as per approved sample. , paper towel dispenser. cabinet 18 8, type 304, size 265x90x365 stainless steel finish: stainless steel satin capacity: 450 c fold, 600 multifold. as per approved sample. , p & f stainless steel hand dryer of approved quality / quality. casing:stainless steel # 304 non magnetic, matt finish mounting :wall mounted operation :touch free infra red activation sensor range : 12 cm 15 cm hand dry time :less than 20 secs auto cutoff: 30 seconds motor:brush type, dual ball bearings speed:25, 000 rpm rated power :550 w ( no heating element ) current:2.5 a protection class :ip x 1 blowing volume : > 270 m3 / h air speed:95 m / s ( with speed controller ) as per approved sample. , modular cubicle based restrooms of stainless steel make with stainless steel hardware with locking arrangement and 1 spare lock each.handles and hinges to be included in the rate. measurement per cubicle. , p & f 1st quality wvc urinal ( is:2556 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc. complete. as per approved sample. , p & f 12mm thick toughened glass urinal partition with all type fitting. ( partition size 300mm x 1050 ) . as per approved sample. , p&f bevelled edge mirror / mirror with 25mm width teak wood lipping including melamine polish around of special glass of approved quality as per direction of engineer in charge complete with 6mm thick commercial ply basefixed to wooden screws & washers. ( size 600 x 450mm x 4 mm thick ) , false flooring providing and fixing cementitious access floor systems of preferred / standard quality confirming to en12825 or equivalent standards. the access floor system to be installed shall be of finished floor height of 450 mm from the existing floor level comprising of 600mm x 600mm cementitious square panels. the system will provide for suitable pedestal and under structure designed to withstand various static loads and rolling loads subjected to it in server / rack area. the entire access floor system will provide for adequate fire resistance, acoustic barrier and air leakage resistance. at least 4 nos. of lifting suction devices to be provided. the raised floor must be capable of withstanding a uniform distribution load of 1500kg / sq. mtr as per specification. it room ( a4 server ) , it room ( a2 & a3 server ) & power room , structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat and two coats of acrylic paint of approved quality for primer and paint all complete. , plain cement concrete m15 grade using graced stone aggregate of 20mm / 40mm max. size including consolidation using vibrator & needle if required finishing, curing, form work shuttering, centering etc. complete all as per specification and in quantity as & when required by the engineer in charge, , hexagon shape ceiling made out of folded aluminium. the hexagon shapeunits shall be in 6 sides customise size of each side 750mm and 1mm ( thick ) , non perforated aluminium. the ceiling hexagon units shall be installed at distance of 300mm one hexagon to second hexagon. the hexagon units are then attached to baffle ceiling ( included in scope of this item ) by slotted cleats and screwing arrangement alongwith bolted brackets attached to ceiling by baffle splice and carrier splice combination with hangers and screw bolting to ceiling which is included in the scope. , providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminium sheet having electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing & supplying stainless steelss 202and aboveperforated type cylindricaldustbinof230mmdia&400mmheightas approved by consultant. . , providingandapplyingthreecoatsofmelaminepolishof requiredfinishtowoodworkbyspraymachineincluding knottingandpreparingthesurfacebyscrapping, applying wood filler, scaffolding if required etc. .complete , providing and applying first quality metallic transparent pu coating of approved quality and shadeon plywoodor veneer wherever required with sand papering & cleaning the surface, applying one coat of primer and lambi / putty including wood filler to full surface 3 times, thereafter polishing the surface in twofinishingcoatsoverbaseprimercoattoachieveeven finish. all complete as per instructions of engineer in charge. etc. complete , supplying&installingsunscreenperforatedrollerblind optima series basket 125 tex with fabric specification of ( fabric composition polyester 22 % and pvc 78 % , openness factor 5%, thickness 0.68mm + / 5%, weight perm2 480.00gsm, yarnscountinwrap / weft / cm19 / 18+ / 5%, fireresistance fr ( usa ) kfi ( korea ) , tearresistance wrap11.9 dan+ / 5%, weft 150 dan+ / 5%, colour fastness 6 7 / 8 ( whitecolourbase ) , artificiallightxenonlamp, uv resistance min 3 ( white colour base ) , width 2.5m & 3 m the roller mechanism shall be a moulded unit made from engineering gradeplastic polymerwith pvcspring support. thefabricshallbeattachedtotherollertubewithhigh quality self adhesive tape with manual operation . the total area of opening covered will be measured. , blackout providing, supplying&installingroller blindsinseclusionserieswithspecificationof basic material 1005polyester, fabricwidth200 / 250cm, fabric weight 20 / 295g / sq.m. thickness 0.50mm finishing blackout fabric, reverse&frontsidepigmentcolourcoatedcolour fastness>5 / 6, rubbing fastness depending on colour, shrinkage wrap:<0.5%withapprovedshadefabric, ( forexternalwindows ) comprisingofpolymercoatedfibre fabric.therollermechanismshallbeamouldedunitmade fromengineeringgradeplasticpolymerwithpvcspring support . the fabric shall be attached to the roller tube with high quality selfadhesive strip.the total area of opening covered will be measured. , supply & fixing rigid autoglow photo luminescent signages, on glowinthedarkrigidsheetwithhighintensityluminous propertiesenclosedintransparentweatherproofuv stabilized coated sheet with uv screen printing by imported ink thickness of photo luminescent sheet 1mm, glow should be visible for 24 hours in total darkness. these signs adheres to pspaclassadin67510part2, bs5499 1, nfpa101etc. complete. any and all sizes below 2ft*2ft. , providing and fixing gypsum cove as per architects drawing between ceiling & wall / column with gi frame support, finished from the top & sides by 12mm thick gypboard including making necessaryhousing for concealed lightfittings, speakers, etc.completeasperarchitectsdetailed drawing and design and as directed with necessary scaffolding etc. complete. , officetable ( maincabintable ) providingandfixing table & pedestal with 3 drawers ( size 400 x450x725 ) to be made out of 19mm thk bwp ( is710 ) marine ply cladded with 4mmthkveneer&finishedwiththreecoatsofmelamine fromoutside&0.8mmthklaminatefinishedfrominside. onlytabletopedgefinishedwithpostform&otheredges finishedinpvcedgebinding.tabletop46mmthickness inside finished with 0.8mm thk laminate.pedestal drawerto be operate with telescopic drawer channel as per detail drawing ) . complete with all necessary hardware & fixture. note : all furniture to be made out ofcalibrated plywood ( is : 710 ) bwpall internal & external surfaces of plywood finishedwithlaminateandveneerrespectively.all hardware complete as perdetaileddrawing & instructions directedbyengineerincharge.includingloading, unloading, transportation, installation. with1yearwarranty. rate to include wire manager system of approved quality size: 1800 x 900 x 750 mm , thrive + with head rest chair. thrive plus high back with headrest and coat hanger .thrive plus high back with headrest and coat hanger generally size in 75 cm * 75 cm height 115 130. , bravo visitor chairs width 61.4cm * depth 64.5cm*height 89.5cm * seat height 46.5cm , sidestorage ( dgmcabin ) providingandfixingside storageunittobemadeoutof19 / 12mmthkbwp ( is710 ) marineplycladdedwith4mmthkveneer&finishedwith melamine from outside & 0.8mm thk laminate finished from inside. only side storage top edge finished with post form & otheredgesfinishedinpvcedgebinding.tabletopinside finishedwith0.8mmthklaminate. complete with all necessary hardware & fixture. note : all furniture to be made out ofcalibrated plywood ( is : 710 ) bwp all internal & external surfaces of plywood finished with laminate and veneer . all hardwarecomplete as per detailed drawing & instructions directed by engineer incharge.includingloading, unloading, transportation, installation. with 1 year warranty.size: 1050 x 400 x 750mm , workstation providing&supplyingat site , workstation comprising of modular 1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge.with1 yearwarranty. ratetoincludewire managersystemofapprovedquality. size : 1350 / 1350 x 600 x 750 / 1200mm , sharing workstation providing & supplying at site , workstation comprising of modular 1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture.. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge with 1 year warranty. rate to include wire managersystemofapprovedquality. size: 1200 x 600 x 750 / 1200. , nonsharingworkstation providing& supplyingatsite, workstationcomprisingofmodular 1200mmheight, 60mmthickness partitionsystemwith powder coated aluminium framing with powder coated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate complete, asperdetaileddrawing&instructionsengineerin charge with 1 year warranty. rate to include wire manager system of approved quality.size: 1200 x 600 x 750 / 1200. , cubicletable cubicletableproviding& supplyingatsite, comprisingofmodular1200mm height, 60mmthickness partitionsystemwithpowder coatedaluminiumframingwithpowdercoated aluminiumcaping..ratetoincludetable, 25mm thick postformed top made out ofcalibrated plywood ( is : 710 ) bwp finishedwith p / f 0.6mm laminate with edge binding, wire management, raceway double raceway soft board+white board combination.in workstation table one side of table understructure 50 x 50full frame metal structure considerwithonesidemetalmodesty ( 600x450ht ) . provisionfornecessarywiremanagementasdirected. complete with all necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is : 710 ) bwp, allinternal & external surfaces of plywood finished with laminatecomplete, asperdetaileddrawing&instructionsengineerin charge.with 1 year warranty. rate to include wire managersystemofapprovedquality. size: 1800 / 1800 x 600 x 750 / 1200 / 700 x 1800 , conferencetable providing and fixing conference table to be made out of 19mm x 2 = 38mm top / / 12mm thk boxing supports of bwp ( is710 ) marine plycladded with 4mmthk veneer&finishedwith melamine from outside & 0.8mm thk laminate finished from inside. all expose surfaces to be 4mm veneer with 48x48mmedgelipping fortabletop&100x 25mm teakwoodedgelippingforsupportingboxingfinish. completewithallnecessaryhardware& fixture. provision for necessary wire management and 6 nosofdeskportof8 moduleas directed ( without electrical ) .complete with all necessary hardware & fixture. etched glass to be installed if required. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfacesofplywoodfinishedwith4mmveneerand3 coatsofp.u.coating, allhardware complete, asper detailed drawing & instructions directed by engineer in charge.includingloading, unloading, transportation, installation. with1yearwarranty.ratetoincludeall provisionofinstallationconcealedspeakersystemand 12mmthickbwpmarine plyapronwith4mmthick veneerfinishonbothsideand20x12mmteakwood edgelipping.ratetoincludewiremanagersystemof approved quality. size: 5500 x 1200 x 750. , meeting table providing and fixing meeting table tobemadeoutof19mmplus12mmtabletopand 12mmthickboxingsupportsbwp ( is710 ) marineply cladded with 4mm thk veneer & finished with melamine from outside & 0.8mm thk laminate finished from rear side.all expose surfacesto be 4mmveneer with37 x 37mmedgelippingfortabletop.completewithall necessaryhardware&fixture. provisionfornecessary wire management and deskport of 8 module as directed ( withoutelectrical ) .completewithallnecessary hardware & fixture. note:.allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate and veneer of . all hardware , complete as per detailed drawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, installation. with 1 yearwarranty.rate to includewiremanagersystemof approved quality. size:2700 x1050 x 750.mm / 600mm dia , cafeteriatable cafeteriatable providing& supplyingatsite31mmthick cafeteriatable comprisingof 25mmthickbwpgrademarineply tabletopwith12mmthk corianfinish &37x 12mmcorianedgebindingthetabletopissupported with s.s.304gradebaseunderstructurecomprising of 75mm diapipe&4pronged withpvcleveller. complete with all necessary hardware & fixture. size: 900 x 900 x 750.mm / 900 x 2970mm , receptiontable providing&supplyingatsite custom made reception table & apron in 19mm marine ply construction inclusive of support framing, table, counter top & drawer box with key board tray asper architect drawing &design. rate to include 19mm thick italian marblecounter top & edging62 x 19mminclusiveofedgepolishing&finishing.basic rate of italian marble rs.800 / sqft. facia to be finish with 12mm thick corian with polishing & buffing, edge bindingwith12mmcorian.concealedledlighting strips with drivers to be installed in pelmet ( led strip is19mmx 12mmwithpolycarbonatecover.all other surfacesinternal&externaltobefinishwithveneer inclusiveofteakwoodedgelippingof10mm thickness. provisionfornecessarywiremanagementas directed ( withoutelectrical ) .completewithall necessary hardware & fixture. note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate . all hardware complete, as perdetaileddrawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, etc. complete. size: 1800 x 750 x 1050mm ht , medium ht storage providing & supplying at site, med ht storage unit 18 mmthick top, all sides, shelf, bottom made out of calibrated plywood ( is : 710 ) bwp with p / f 0.6mm laminate, other edges finished with 2.0 mm thick pvc edgeband for exposed edges & 0.8 mm thick for non exposed edges t.complete as per architects detailed note :all furniture to be made out ofcalibrated plywood ( is : 710 ) bwp, all internal & external surfaces of plywood finished with laminate . all hardwarecomplete, as per detailed drawing & instructions directed by engineer in charge. including loading, unloading, transportation, installation., with 1 year warranty. size : 900 x 450 x1200mm , lockers providing & supplying at site, locker storage unitof8compartments18mm thicktop, allsides, shelf, bottom& shutters made out of calibrated plywood ( is:710 ) bwpwithp / f0.6mmlaminate, other edges finished with 2.0mm thick pvc edgeband forexposededges&0.8mmthickfornonexposed edges complete, as per architects detailed note:allfurnituretobemadeoutof calibrated plywood ( is:710 ) bwp, allinternal&external surfaces of plywood finished with laminate . all hardware complete, as perdetaileddrawing & instructionsdirectedbyengineerincharge.including loading, unloading, transportation, installation, with 1 year warranty. rate to include locking arrangement with hinges, handles&hardware.size :1050x450x 2400mm. , revolving type chair with wheels : seat assembly : the cushioned seat is made of injection moulded plastic outer & inner. plastic inner is upholsteredwithleatherette andmouldedhighresilience ( hr ) polyurethane foam ofdensity45±2 kg / m³ and hardness load 16 ± 2 kgf as per is:7888 for 25% compression * seat size : 47.0 cm ( w ) x 48.0 cm ( d ) backassembly: thecushionedbackismadeofpu foam with insitu moulded ms moulded e.r.w.round tube of size1.9±0.03cm x0.16±0.0128cm.itupholsteredwith leatherette.*mid back size : 47.7 cm ( w ) x 60.1cm ( d ) armrests: thearmresttopismouldedfrom polyurethane ( pu ) and mounted on to a drop lift adjustable type tubular armrest support made ofø 3.81 ± 0.03 cmx 0.2 ± 0.01cm thk m.s.e.r.wtube having chrome plated finish . thearmrestheightadjustableupto6.5±0.5cm in5 steps. seatdepthadjustment: seatdepthadjustmentis integrated in the seat through a sliding mechanism. seat depth adjustmentrangeisof6.0±0.5cm.adjustable back support : back frame is connected to the up / dn mechanismhousedinplastictspine.itcanbeadjustedin the range of 7.42 ± 0.5 cm for the comfortable back support to suit individual need .active bio synchro mechanism: the adjustable tilting mechanism is designedwiththefollowing features: • 360°revolving type . djustment : the pneumatic height. adjustment has anadjustment stroke of 10.0 ± 0.3 cm . , revolving type chair with wheels: seat / back assembly : the seat & backis made up of 1.2±0.1cmthk. hotpressedplywoodmeasuredasperqa method describedin qcp olta pl14 18:upholstered with synthetic leather over moduled high resilience polyurethane foam. • high back size : 51.8 cm ( w ) x 75.2cm ( h ) • seat size : 49.0 cm ( w ) x 48.8 cm ( d ) high resilience ( hr ) polyurethane foam : the hr polyurethanefoam ismoduledwithdensity=55+ / 2 kg / m³andhardnessload16±2 kgfasis:7888for25% compression. armrests : the adjustable armrest is designedwiththefollowing features • up down adjustment 8 steps ( 8.0 ± 0.5cm range ) • height adjustable armreststructurewhichischromeplatedandfittedwithan armrest top • fixed armrests topispu moulded over metal insert. backheightadjustibality: backcanbe adjusted in 5 positions by manually .stroke of height adjustable spine is 7cm.back height adjustability is applicable for high back & mid back chairs .pneumatic height adjustment : the pneumatic height. adjustment has anadjustment stroke of 10.0 ± 0.3 cm . , bean bagchairs xxl size of approved colour, shade and material as per the direction of engineer in charge , providing, fixing, installing & putting in place& in proper condition, as per layout & as per direction of the engineer in charge.seating asperfollowingdetails. basicratefor fabric upholstery rs 450 / .per mtr: 1seater sofa size: ( 860w x 905d x 855h ) seatfoam:theseatismadeupofpufoamindensity 28±2 kg / cu. mtr with an additional top layer of supersoft pu foam in density 32±2 kg / cu, upholstered with fabric or leatherette. backfoam:thebackismadeupofpufoamdensity 28±2kg / cu, mtrwithtwoadditionaltoplayerofsupersoft foam ofdensity 32±2kg / cu, mtr, upholstered withfabric or leatherette. undersructure:understructureismade upof 1.2±0.1 cm. thick hot pressed plywood ( moisture resistance & termite proof as per is:303 ) & pinewood of cross sections devoid of majorknots&surfacedefects.6nosperseat&3.8mm dia zigzagspringassemblyismountedoverunderstructurefor cushioning purpose. leg assembly: it is a welded assembly made in stainless steel ( grade ss 202 ) tube & plate with plastic endcap the product to be tested and passed the quality standards as laid down under iso 9001, 1s014001, iso18001, ohsas andbifmacertificationsforqualityassurance.ithasa green assurance card validated by tuv india. location staff & wherever required, , electrical , dg set , supply , installation, testing & commisioning of diesel generating ( d.g. ) set with class g3 governing ( 40% step load ) , alternator of 325 kva output at 0.8 pf continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 v, 50c / s, radiator cooled, multi cylinder diesel engine at 1500 rpm , seperately excited amg having class h, spdp alternator ( with battery charging generator ) , with static avr + / 1% & thd<3%, running at 1500 rpm. both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having engine & generator protection ( including ref & rpr ) / parameter display / operator interface / power command 3.3 control system / amf panel / synchronization / dedicated earthing system / rs 485 modbus connectivity, etc. the complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 db at 1 meter, made of 16 / 14 swg crca sheet, complete with first filling of lube oil / diesel / coolant & fuel hoses, battery, 990 liter external fuel tank, residential silencers, mounted on plinth & obtaining necessary approval from electrical inspector. a. amf panel comprising of suitable rating fp edo acb for mains and d.g., auto / manual selector switch, engine start / stop push button, indication lamps, voltmeter / ammeter / kwh meter / rpm meter / hour meter / announciator / relays / battery charger / dc ammeter / voltmeter, etc. b ) exhaust piping to be raised upto terace level of nearest building. c ) power / control cabling, terminations, etc. d ) 990 ltr. capacity external diesel tanke ) . height of stack to be maintained as= height of building + 0.2 * vkva . f ) factory testing to be carried out in present of actrec engineering before despatch of equipments. , supply, installation, testing and commissioning of following all indoor panels comprising below points. 1 ) panels shall be fabricated out of 16 / 14 swg crca sheet steel, with necessory structural supports in form of structural steel sections. 2 ) floor mounted, ip 52 degree protection, top bus duct or cable entry as per the case & top cable exitsteel, 2mmframe, 1.6 mm compartments & tank process treated & 2 times epoxy painted. 3 ) the panel shall be compartmental, form 3b type, with suitable size of bus bar and separate cable and busbar chambers. 4 ) proper gland size holes to be provided bythe manufacturer with proper sticker and danger sign on all sides of panel. 5 ) the cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination. 6 ) current density 1.2 ampere / 1 sq.mm for copper and 0.8 ampere / 1 sqmm for aluminium ( is 8623 for factory built assembly ) . specification of copper for copper bush bar c11000 electrolytic tough pitch ( etp ) . 7 ) earthing terminal.8 ) fault level 50ka / sec.9 ) panel inside illumination to be provided10 ) receptacles , space heater provided as per standard. 11 ) epoxy paint colour type ral 7032 to be use. , l.t. panel 1 & 2 ( as per sld attached ) , office panel ( as per sld attached ) , utility panel 1 & 2 ( as per sld attached ) , 30kva ups o / p panel ( as per sld attached ) , pdu 1 & 2 ( as per sld attached ) , 5kva ups o / p db for emergrncy lighting and ibms load. ( as per sld attached ) , automatic changeover switch ( ats ) , 32a 4p automatic changeover switch ( ats ) , ups system , supply , installation, testing & commisioning of 80kva online, pure sine wave modular ups system, 3 phase input and 3 phase output with upf, 0.96% efficiency, igbt based rectifier technology, isolation transformer, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , supply , installation, testing & commisioning of 30kva online, pure sine wave modular ups system, 3 phase input and 3 phase output with upf, 0.96% efficiency, igbt based rectifier technology, isolation transformer, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , supply , installation, testing & commisioning of 5kva online, pure sine wave modular ups system, 1 phase input and 1 phase output with upf, 0.96% efficiency, igbt based rectifier technology, suitable capacity smf batteries for minimum 20 minutes backup, battery rack, cables for interconnections. ups should have provision of auto & manual bypass in case of any internal fault in ups system.80% dod is accepted for li battery , acceptable inputthd 5% , distribution boards , supply and fixing of tpn, double door power distribution board having 63 amps tpn mcb 1 no. / / / 40 amps , 10ka , dp elcb ( 30 ma ) 3 nos / / / 20 / 32 amps sp mcb ( 8ways ) 24 nos. ip 55, ik 08, , supply and fixing of tpn, double door lighting distribution board having 63 amps tpn mcb 1 no. / / / 40 amps, 10ka , dp elcb ( 30 ma ) 3 nos / / / 10 amps sp mcb ( 12ways ) 36 nos.ip 55 , ik 08 , supply and fixing of spn, double door power distribution board having 32amps , 10ka dp elmcb 1 no. / / / 16 amps , 10ka dp mcb 6 nos. , ip 55 , ik 08 , supply and fixing of spn, double door lighting distribution board having 16amps 10ka , dp elmcb 1 no. / / / 10 amps , 10ka sp mcb 6 nos., ip 55 , ik 08 , mains wiring , wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. , 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , point wiring , wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. , wiring for plug on board, switch with multi socket concealed type and copper wiring, earthing and with modular accessories. , providing fan regulator on board with modular switch and regulator. , switches, sockets & accessorie , supplying and fixing of 3 / 4 module switch box with modular plate including connections but excluding modular plate etc. as required. , 15 amps switch , 5pin 5 / 15 amp socket outlet , 32a 3p+n+e socket with plug ac powerenclosure and mcb , 16a 1p+n+e mobile socket with plug ac power , lighting fixtures / exhaust fans / ceiling fans , supplying and erecting of recessed type square shaped crca / die cast aluminum powder coated housing led panel light 600x600mm of premium range suitable for upto 36 w with provision for plane front frame with translucent cover fixed to the housing complete.lumens output >3200 , cri more than 80 , cct 6500k, thd <10% , supplying and erecting led square / circular 13 to 18 w premium range down lighter having pressure die cast aluminum housing with white front frame with opal translucent cover with provision for spring loaded mounting clips complete. lumens output 900 / 935 / 980 , cri more than 85 , cct 3000k to 6000k, thd <10% , supply and erecting of box type led light fitting with 1 x22w led tube light complete with all accessories. , standerd 230v ceiling mounted day light cum occupancy sensor. , supply and fixing of call bell with all accessories. , supply and fixing of 225mm sweep exhaust fans. , supply and fixing of 1200mm sweep ceiling fans. , cable tray , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 300 mm width & 50 mm height complete with necessary coupler plates, support & hardware in approved manner.coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 500 mm width & 75 mm height complete with necessary coupler plates, support & hardware in approved manner. coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , supply , installation, testing & commisioning of hot deeped galvanised perforated type cable tray manufactured from 16 swg ( 1.6 mm thick ) gi sheet of 750mm width & 75 mm height complete with necessary coupler plates, support & hardware in approved manner.coating thickness of hot dip galvanized cable trays will be 80 to 100 microns or 610 grams per square meter ( depends on thickness ) and follows is: 2629, 1985&is 4759. , lt cables , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx300 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx185sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx150sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx70 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx50 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx35 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls, xlpe armoured cable 3.5cx25 sqmm aluminium conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx70sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx35 sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 1cx10 sqmm copper conductoron wall / in provided tray as per instructions. , supply and laying of 1.1kv, frls multicore flexible cable 3cx6 sqmm copper conductoron wall / in provided tray as per instructions. , supply and fixing of end termination with brass double compression gland andlugs of copperor aluminiumor bi metallic lugswhich are suitable at sitefor following size of frls insulated and xlpe aluminium conductor cable of 1.1 kv grade as required. , 3.5c x 300 sq.mm. , 3.5c x 185 sq.mm. , 3.5c x 150sq.mm. , 3.5c x 70sq.mm. , 3.5c x 50sq.mm. , 3.5c x 35 sq.mm. , 3.5c x 25 sq.mm. , 1c x 70 sq.mm. , 1c x 35 sq.mm. , 1c x 10 sq.mm. , 3c x 6 sq.mm. , earthing , supply and fixing of 50 mm x 6 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 40 mm x 5 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 25 mm x 3 mm copper strip on surface or in cable tray for connections etc as required. , supply and fixing of 8 swg copper wire on surface or in cable tray for connections etc as required. , tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like cole, charcoal, salt, brass nut bolts & washers, watering arrangements, gi pipe ( b class ) , concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. the chamber cover & plate shall be of heavy duty hinged type & it shall weigh approx. 65 to 75 kgs. plastering shall be done both inside & out side.the measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by engg in charge. , chemical earthing / maintenance free earthpits having better earth resistance value. , addressable fire alarm systems & detection systems : , supply , installation , testing and commissioning of addressable automatic dual led smoke detector with two integrated light scattering smoke sensors using leds with different colors / wavelengths ( blue / infrared ) to avoid false alarm & should comply to test fire 1, including mounting base with led, drift compensation feature & automatic addressing.high resistance to electromagnetic effects in accordance with efsg agreement efsg / f / 97 / 005 shall be en54 / vds / ul certification.2isolators ( one for incoming & one for outgoing line ) integrated in detector for maintaining operational availability of all elements in the loop , even in the evennt of a short circuit, bosch model fap 0 420 or equivalent. , sitc of addressable thermal detector including mounting base with led..etc complete as required with inbuilt isolator.temprature sessor triggers@ 54deg c or 69 deg c & drift compensation feature.shall have ul / vds certification bosch model fah t 420. , supply, installation, testing & commissioning of addressable, ul listed, duct smoke detector comprisingsplash & hose proof, uv resistant, housing assembly with sampling tubes & photoelectric detector with heat element ( 57deg c ) , suitable for air speeds of 100 4000 fpm, loop powered, class a wired, low profile, temper resistant, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , wiring box, in / out cable glands. , supply, installation, testing & commissioning of addressable, ul listed, control module for switching power supply to hooter & strobe, loop powered, class a wired, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , suitable for surface / recess installation, wiring box, in / out cable glands. , supply, installation, testing & commissioning of addressable, ul listed, control module with relay for ahu / damper / switchgear operation, loop powered, class a wired, low quiescent current, rotary / dip decimal address setting switch, 24v dc ( 15 32v ) , suitable for surface / recess installation, wiring box, in / out cable glands. , supply at site, installing in proper position testing and commissioning of 2 core x 1.5 sqmm frls armouredcopper conductor cable of approved quality all complete as required and as per final direction. , removing and refixing of detectors, isolators, monitor moduls, control moduls, etc. , supply and fixing of junction boxes with cable glands, lugs, etc. , fire suppression system comprising of following , novec 1230 based fire suppression system comprising of the following items: , sitc of ccoe approved ul listed seamless novec 1230 cylinder and valve assembly, 120 ltrs. capacity, oem factory filled with novec 1230 suppression liquid ( item no. 2 ) , pressurised to 25 / 42 bar. along with hydraulic flow calculations for the suppression areas, and vetting of the software results from the oem factory engineer. , sitc of ccoe approved ul listed seamless novec 1230 cylinder and valve assembly, 80 ltrs. capacity, oem factory filled with novec 1230 suppression liquid ( item no. 2 ) , pressurised to 25 / 42 bar. along with hydraulic flow calculations for the suppression areas, and vetting of the software results from the oem factory engineer. , sitc of novec 1230 fire protection fluid, oem factory filled per kgs. , sitc of tank bracket assembly complete with c channel stand and supports for above cylinder. the price shall include ms fabricated floor supported cylinder support stand, wherever required. complete with 1 coat of primer and 2 coat of black enamel paint. ( refer drawing for cylinder locations ) . , sitc of ul listed discharge hose withmanifold check valve ( check valve if more than one cylinder in bank ) for above cyilnders, complete with listed adapters & accesories as required. , sitc of ul listed electrical actuator for master cylinder. , sitc oful listed local manual actuator , sitc oful listed pneumatic actuator shipping assembly with actuation hose & elbow. , sitc oful listednozzles, 360 deg / 180 deg throw, selection as per approved hydraulic flow calculations. , sitc of warning sign board with marking gas discharge. do not enter. shall operate on 24 v dc, driven through gas release panel. ( for use outside room ) , sitc of warning sign board with marking gas discharge. evacuate immediately. shall operate on 24 v dc, driven through gas release panel. ( for use inside room ) , sitc of ul listed cylinder low pressure switch , sitc of ul listed cylinder discharge pressure switch, shall be install on the novec piping after discharge hose. , sitc of novec piping & manifold as required, sch 40; astm a106 gr b, as per flow calculations for the specific hazard volume and stand to hold, position & support the manifold and piping properly. pressure testing for piping with nitrogen as per nfpa 2001. , supply installation testing & commissioning oful listed single zone gas release panel facility to connect manual abort / release switches. the panel shall provide potential free contacts for first knock, second knock, trouble / fault status. the panel shall be complete with red colour housing, monitored power supply unit, battery charger & batteries. , supply installation testing & commissioning ofmanual abort stations, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. the abort will be monitored simultaneously by fire alarm or bms system. , supply installation testing & commissioning of manual release stations, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. the release switch will be monitored simultaneously by fire alarm or bms system. , towards conducting room integrity test : door fan test to meet the requirements of the nfpa 2001, and predicting the efficacy of the protected area enclosure from the perspective of fire suppression. , supply installation of 2 core x 1.5 mm2, multistranded at copper, frls armoured cable, red in colour. the cable shall belaid on surface with gi saddle spacers every 0.3 meters. complete with gi junction box, lugs, cable compression glands, cable tags and ferruling. , public address system , supply, installation, testing and commssioining offollowing items , ul listed, 6 watt ceiling mount speaker with junction box for ceiling mount , goosneck micro phone , cd / mp3 player , 6 zone selection panel for pa announcement , rack to mount amplifier, cd player and console , 2 core 1 sq.mm copper conducter cable with 20 mm dia pvc conduits , lannetwork , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed pvc conduit as required. , supplying, installing & testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. , supplying and fixing following 3 module, gi box along with modular base & cover plate as required. , supplying and fixing 1 meter length, utp patch cord of cat 6 type in position as per requirement. , supplying and fixing 24 port patch panel with tool less keystone jacks in provided u rack complete as per requirement. , supply & fixing of 25mm pvc conduit with accessaries. , sitc of it rack 19 wall mounted president quality rack 15u ( double section ) with acrylic glass door with the accessories [ two fan position tray with two 90 cfm fans ( ac 230v ) , 3 horizontal cable manager 3nos, ac power panel strip with 5 x 5 amp sockets , fuse and on / off switch, 1 packet mounting hardware , supplying and fixing 7 ft length, utp patch cord of cat 6 type in position as per requirement for end point device ( pc / laptop etc ) , sitc of lazr speed 300 fiber, 6 core indoor application, multimode, to be laid through conduit and flexible with all the connectors, couplers, pigtels, lius at both end , telephonenetwork , supplying & erecting jelly filled armoured telephone cable 20 pair with 0.5 mm dia. , supplying, erecting & commissioning of telephone tag block with crone module suitable for 20 pairs as required. , supplying and fixing of rj 11 / rj 45 modular telephone socket with g.i. switch box, modular plate including connections as required. , supplying, installing, testing & commissioning approved type push button telephone instrument desk top / wall mount unit as per specification in approved manner. ( panasonic model no kx ts 580 ) , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed pvc conduit as required for ip phone. , ip telephone instrument. , 24 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24x10 / 100 / 1000poebase tports, 2fixedsfp ( 1g ) withinternalpowersupply ( 192wpoe budget ) . , 8 port poe network switch’s, gigabit ethernet web smart chassis in a 1u form factor with 24x10 / 100 / 1000poebase tports, 2fixedsfp ( 1g ) withinternalpowersupply ( 192wpoe budget ) . , 12u wall mounted double section rack with acrylic glass door having 2 nos. 90 cfm fans, cable managers, 5a sockets, fuse, on / off switch, 1 packet mounting hardware, etc. , supply & fixing of cat 6 , 24 port patch panel loaded. , supply & fixing of 2 mtr. patch cord. , supply & fixing of 25mm pvc conduit with accessaries. , cctv system , supply, installation, testing and comissioningof the following equipment for cctv system , indoorip base day & night, 2mp hd resolution with ir illumination, varifocal lens cmos, resolution 1920x1080p @ 25 fps, widedynamicrange @ 90 db, wdr ccd dome cameras, 2.8mm to 12mm ir lense, min. 15mtr coverage, sd / sdhc memory card slot., camera should be poe enabled. the camera should be onvif compliant. , indoorip base day & night, fixed dome cameras, 2.8 mm ir lens, minimum 110 degree of horizontal field of view, resolution 1920 x 1080p @ 25 fps, 10 mtr coverage, camera should be poe enabled. the camera should be onvif compliant. , supply, installation, testing and commissioning of 16 port 10 / 100t managed poe access switch with 2 sfp uplinks ( layer 2 ) . configuration to be decided by vendor base on real time image transmission from camera / encoder to server. all the switches should be in racks. , supply, installation, testing and commissioning of 16 ports 10 / 100 / 1000t managed poe switch ( layer 3 ) along with sfp module. configuration to be decided by vendor base on real time image transmission from camera / encoder to server. all the switches should be in racks. , nvr / nas & vms , supply, installation, connfiguration, testing & commissioning of video networked recorder ( nvr ) of suitable channel with 30 days motion based storage at 20 fps, along with vedio management software ( vms ) along with required camera license. , supply , installation , testing and commisioing ofcat 6 cable for power / data cabling from camera to switchwith 25 mm pvc conduit. , supply, installation, testing and commissioning of color high resolution led tv comprising of 42 display, full hd, hdmi input provision; complete with all supports and accessories. , sitc of 6pair multimode fiber optical cable with termination all necessary accessories and termination as required. , cat 6 iowith back box & surface plate , cat 6 patch cords , access control system comprising of following , supplying, installing, testing & commissioning of the access control system consisting of the following: , supply , installation, testing and commissioning of 4 reader ip based door controller for controlling the above card readers as per specification mentioned including all accessories.max. 4 reader combition ( tenderer to mention quantity of controllers based on their system. ) system should have capability to expand up toadditional 100 doors in future. , supply , installation, testing and commissioning of 2 reader ip based door controller for controlling the above card readers as per specification mentioned including all accessories.max. 4 reader combition ( tenderer to mention quantity of controllers based on their system. ) system should have capability to expand up toadditional 100 doors in future. , sitc of biometric fingerprint + pinpadreader , supply , installation, testing & commissioning of proximity card readers as per specification suitable for mounting on metal surface / metal frames or wooden frames wall or as required based on site conditions including all accessories , sitc of panic bar with egress switch , supply , installation, testing and commissioning of smart cards as per specification. , sitc of break glass unit for access doors , sitc of single leaf electromagnet door holder ( fail safe type ) of 600 lb holding force , sitc of double leaf electromagnet door holder ( fail safe type ) of 600 lb holding force , sitc of door contact sensor , sitc oftime, attendance and visitor management software for access control with seamless integration with bms module, visitor management module and time and attendance module as per the specifications. software shall be capable of handelling additional 10 nos. of access readers. , supply , installation , testing and commisioing ofclient workstation processor intel core i 7 os genuine windows xp / 7prof colour monitor 21 flat panel lcd / led monitor ram 16 gb ddr3 sdram memory 1 tb hdd a4 laser jet printer network: 100 / 1000 mb ethernet network card resolution support: 1024 by 768; 1280 by 1024; 2048 by 768; 2560 by 1024 , cables & accessories for acs system , supply , laying , testing and commissioning of the following cables signal & communication cablesfor security access control, alarm monitoring system with all accessories including glanding and termination. , 6 cx 1sqmmshielded armouredsheilded cable , 4cx 1sqmmshielded armouredsheilded cable , 2cx 1sqmmshielded armouredsheilded cable , cat 6 cable for network controllers with 25 mm pvc conduit , building management system comprising of following: , the rate of each item of work for bas shall also include the following : 1. all materials, fixing materials, accessories, appliances, tools and equipment. 2. approvedcoverplates for inspection, junctionandoutlet boxes. 3. 2 mm thick outlet boxes and junction boxes. 4. all fixing accessories such as clips, nails, screws etc. 5. providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed cable work. 6. embeddingcablesand accessories inwall, floorsetc.duringconstruction and / or cutting chases and makinggood as in the case of all concealed cables work. 7. testing and commissioning of each device as per approveddesign concept , sitc ofduel core2 quad, 80gb hdd, 2ghz processor, 8gb ram, 52x cd rom drive 1.44 fdd, 17 colour monitor, microsoft bus mouse, 2 serial, 1 parallel port & windows xp operating system , sitc of colour inkjet printer , supply of necessary software packages containing building management & control software programmes with dynamic graphics interfaces , software and hardware required for integration of following third party system with bms , energy meters 5 nos. , ups 4 nos. , dg ( 2 nos ) & transformer ( 1 no. ) , cooling unit8 nos. , pdu 2 nos. , supply, installation, testing & commissioning of stand alone, intelligent, ul listed, interoperable ddc . , ddc controller for monitoring as per io summary , room temperature cum rh sensor , room temperature sensor , outside temperature and rh sensor , hydrogen sensor , wi fi modem for tap off box meters data connectivity. , signal cable 2 core 1.5 sq.mm pvc insulated cu armoured cable , communication cabling ( cat 6 ) for bms in pvc conduit , supply , installation , testing and comissioning of 16 port unmanaged network poe switch with accessories. , rodent repellent system comprising of following: , digital master console catering lp 12 satellites for rodent repellent system , satellites ( streem ) , wall mount bracket , 2 core 1 sq.mm cu. flexible shielded cable bundle ( 300 yards ) with 20mm pvc conduit , rrp software , water leak detection ( wld ) system: , sitc of water leak detection panel with modbus connectivity ( for all data center server area , ups locations and electrical control rooms ) , sitc of water leak detection module , water leak detection cable sensor , electronic hooter , 2 core x 1.5 sqmm frls armoured copper cableas per technical specification , miscellaneous items , 150x150x3mm danger notice board & 415 enameled danger board , 150x150x3mm danger notice board & 11kv enameled danger board , shock treatment chart with frame in local & english language , first aid medical box , supplyandinstallationof9 kgcapacityco2 typefire extinguishers conforming to is : 2171 , abc type – manual fire extinguishers with 6kgs. , providing of set of 4 nos.9.5 litre capacity g.i. buckets painted in post office red colour with prior coat of red oxide paint and written with white paint fire and , mounted on ms angle iron frame with bracket of appropriate size and capacity including , 1000 x1000 mm wide 2.5mm thick rubber matting suitable for 1100 grade , providing pair of duly tested rubber hand gloves as per is:340715 suitable for working on 11kv and 415v supply. , 50mm size pvc flexible conduit , 25mm size pvc flexible conduit , 50mm size pvc rigid conduit with accessories , 1 year warranty is included in the above items. cmc rate ( electrical components ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to six years without any escalation clause , hvac , variable refrigerant volume ( vrv ) , sitc of variable refrigerant volume modular type air conditioning equipment complete with indoor and out door units with central control system unit shall have central controller for controlling all the indoor and outdoor units and should be capable of integration with the computer system based building management system of hvac , outdoor unit , supply installation, testing & commissioning of modular type variable refrigerant flow / variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor ( s ) , minimum two compressors for above 14hp modules, microprocessor based controller , top discharge type condensing unit ( s ) , with r410a refrigerant, vibration isolators, with suitable foundation etc. complete as required. the unit shall deliver the rated capacity at ahri condition sand work even at 50°c ambient temperature without tripping. the unit shall be suitable to work on 400v+ / 10%, 3phase, 50hz ac power supply. the unit shall be filled with first charge of the refrigerant and ready for use as required. the cop at ahri conditions shall not be less than 3.1 and ieer not less than 6.5 , system 1 : 18 hp ( cold type ) , system 2 : 10 hp ( cold type ) ( 2w+1s ) , indoor units ( vrv / vrf compitable ) , supply, installation, testing and commissioning of following minimum capacity 4 way flow vrv / vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230v±10%, 50hz ac supply, complete, asr equired. the unit shall have automatic force shut down provision in case of fire on receiving signal from bms system.the cooling capacity of indoor unit wil be at air inlet conditions of 27 degreec db and 19 degree c wb temperature. , cassette unit with inbuilt drain pump , 2.8 tr , 2.4 tr , 1.6 tr , supply, installation, testing and commissioning of following minimum capacity vrv / vrf high wall type indoor unit equipped with synthetic washable media pre filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230v±10%, 50hz, single phase ac supply, complete as required. the unit shall have automatic force shut down provision incase of fire on receiving signal from bms system. the cooling capacity of indoor unit will beat air inlet conditions of 27 degree c db and 19 degree c wb temperature. , 2 tr , 1.65 tr , 0.8 tr , floor mounted ahu vertical / horizotal , supply, installation, testing & commissioning of double skin floor mounted horizontal / vertical ahu having 50 mm sandwiched puf insulation ( 0.80 mm thk inner skin & 0.80 mm thk outer plasticized gi ) . it shall have pre filter ( 90% down to 10 micron ) of washable type > 6row vrv / vrf dx cooling coil having 12 13 fpi and anti corrosion coatingfins with face velocity of 500 fpm > didw kruger quality backward curved fan with tefc squirrel cage induction motor with drive set. other accessories like inspection door, vibration isolator, limit switch, marine light, outlet mouth damper for supply to be provided. insulated ss 18g drain pan with 19mm thich class o nitrile rubber insulation. the outlet velocity not more than 7.5 m / sec. motor shall be ie3, class f insulation, ip55 rating, & suitable for 415 ± 10 % volts, 3 phase, 50 cycles ac supply. the noise level should be less than 65 dba at 1.5 m distance. unit to be tripped on receipt signal from fire damper installed in the room and interconnection with fire damper shall be provided. note: ahu should supply with inbuit control panel which is bms compititble. , 14 tr / 5600 cfm / 50 mm esp ( external static pressure ) ( vendor to verify the esp as per drawing for supply and calculate the total including internal pressure drops filter / coil / etc. ) ahu should have 1working +1 standby motor. , ahu connecting kit , refnet joints and other fittings , supply and installation of hard drawn 16g copper tubing insulated with 19 mm thick class o nitrile rubber insulation with gc cloth insulation shall be provided with weather proof additional cover for exposed areas. for indoor units tubing of appropriate diameter to be provided. all piping inside the room shall be properly supported with hanger and all external piping shall run in covered cable tray. piping quantity is mentioned is for pair of suction and discharge pipes. , gas charging and testing & commissioning of the system , supply & installation of transmission & control wiring with gi conduit between indoor and out door unit. , ( 2 core x 1.5 sq mm cu.cable ) , 4 core x 4 sqmm cu cable , supply & installation of support arrangement for out door units, ahu with necessary vibration isolation arrangement, ms frame for mounting the units to be provided with rubber pads, the frame should be painted with two coats black colour synthetic enamel paint. , supply & installation of gi class c drain pipe with 13 mm thk nitrile rubber insulation , 32 mm dia , 25 mm dia , supply & installation of perforated type powder coated m.s. cable trays of 50 mm in height & 2.5mmthick with two coats of red oxide and with necessarysupporting frame etc , 200 mm wide , 300 mm wide , supply & installation of bms integration charges for the vrv outdoor unit / indoor units from central controller to bms. all the outdoor / indoor unit parameters will be integrated through bms & required hardware / software to be included via modbus / bacnet. , supply , installation , testing & commissioning of split type airconditioners with scroll compressor comprising indoor air , outdoor condensing unit, with stand and all other necessary hardware for proper hanging of units. , hiwall split 2.0tr ac ( 3 star rating ) , hiwall split 1.5tr ac ( 3 star rating ) , all refrigerant piping shall be of copper, complete with supports between indoor & outdoor units duly insulated with 13mm nitrile rubber insulationwith gc cloth.rmt indicated is for set of piping between indoor and outdoor machine, individual piping will not be measured. , 1 / 4, 5 / 8 or equivalent to the unit , 1 / 4, 1 / 2 or equivalent to the unit , air distribution system , design, supply, fabrication and installation of g.s.s. ductingon every branch if there is, with required hardware’s, supports, wooden frame and painting on ducts, ms parts etc as per the smacna standard, approved drawings and instructions of engineer in charge with the following gauges. the ducts shall be fabricated from galvanized steel sheets class viii light coating of zinc conforming to iss: 277 1962 ( revised ) with accompanying mill test certificates.galvanizing shall be of 120gms / sq.m. ( total coating on both sides ) .exposed duct should provide with 26g aluminium cladding. , 24 g ( 0 750 ) , 22 g ( 751 1500 ) , 20 g ( 1501 2250 ) , 18 g ( 2250 above & plenums ) , supply, installation, testing and commissioning of gi volume control duct damper with bronze bush bearing complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. , 18g gi constructed vcd , supply, installation, testing & commissioning of back draft damper , 18g gi constructed bdd , supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , supply, installation, testing and balancing of powder coated extruded aluminium return air diffusers with removable core in accordance with the as directed and as instructed by oic es , supply, installation of extruded al. powder coated louvers for fresh air intake & exhaust complete withss bird screen mesh. , supply, installation, testing and balancing of extruded al. powder coated supply / return / exhaust air grilles with bronze bush bearing sleeve of different sizes , without collar damper , 150 x 150 with collar damper for toilet exhaust , supply installation testing and commissioning of motorised fire & smoke damper , casing made of 16g gi with factory fitted gi sleeve of 18g, 120 min fire rating complete with standard accessories as per ul 555s. , total area fire damper with pvc gear ( only damper price ) , smoke / fire sensors with all controls, accessories, actuators, extended sleeve for wall mounted ( actuator outside wall ) and other accessories torque 5 nm , supply, fabrication, installation and testing of the flexible connections constructed out of fire resistant double canvas sleeve as per instructed and as directed by oic es , supply, installation, testing and balancing of extruded al. profile powder coated supply & return slot diffuser of diiferent sizes. , 4 slot of 25 mm slot opening , hit & miss damper , inline fan , supply, installation, testing & commissioning of cabinet type / in line fan complete with forward curved / didw centrifugal fans, motor and drive. it shall be suitable for 230 ± 10% v, 1 phase, 50hz ac supply.. other accessories like inspection door, vibration isolator outlet mouth damper to be provided. , cap:500 cfm / 12 mm wc , insulation , supply and installation of external thermal insulation class o closed cell elastomeric nitrile rubber insulation with adhesives on ducts, tapes as per instuction and as directed by oic es , 13 mm thick for supply air duct in return air path , 19 mm thick for supply air duct , supply, installation and testing of acoustic lining for supply and return air ducts of following thickness of rigid fiber glass of 50kg / cum density covered with factory laminated rp tissue and finished with 26g perforated aluminium sheet as per the specifications. , 25 mm , 1 year warranty is included in the above items. cmc rate ( hvac components ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to six years without any escalation clause , part – b: hpc, cdc and other related work , research cluster head node 1 ( 1+1 redundency ) : dual intel xeon gold 5320 26 core, 2.2 ghz; 128 gb ecc ddr4 ram; shared storage – raid 5 / 6 usable 10 tib read intensive ssds or sas 10k rpm hdd with hot spare, ha configuration , research cluster login 1 ( 1+1 redundency ) : dual intel xeon gold 5320 26core, 2.2 ghz; 512 gb ecc ddr4 ram; shared storage – raid 5 / 6 usable 1.9 tib read intensive ssds or sas 10k rpm hdd with hot spare, load sharing with dns server , research cluster general nodes 1: dual intel xeon gold 6348 28 core, 2.6 ghz; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds , research cluster high memory nodes 1: dual epyc 7763 64 core, 2.45 ghz; 2048 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 1.9tb mixed use ssds , research cluster gpu nodes 1: dual intel xeon gold 6348 28 core, 2.6 ghz; ( or equivalent / better amd cpu ) ; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds; 2 x tesla a100 ( 80 gb ) nvlink / bridge , research cluster gpu nodes 2: dual intel xeon gold 6348 28 core, 2.6 ghz; 256 gb ecc ddr4 3200 ram in 100% balanced memory configuration; 2 x 960gb mixed use ssds; 2 x rtx a6000 / a40 nvlink or pcie , research cluster interconnect / network 1: a ) gigabit switch with all the compatible cables for managing all the cluster components with sufficient ports. managed switches with rps and redundant fans need to be offered in the solution. b ) gigabit switch with 10g sfp+ uplink ports , all the structured cabling and other required components for connecting all the client devices ( approximately 40 clients ) in the office area; 100g hdr infiniband off loading fat tree internally managed network on hdr 200 switches, secondary cluster management 1g network switches, remote management 1g network switch. managed switches with rps and redundant fans need to be offered in the solution. kvm switch with display, keyboard / mouse and adequate ports is required at each site for easy monitoring and troubleshooting of installed servers. , research cluster storage scratch 1 lustre: 1 pib usable on raid 6 ( 8+2 ) as per below : 200tib ( 50 gib / s write / read each individually ) must be offered using flash drives and 800 tib ( 10 gib / s write / read each individually ) must be offered using ssd / nl sas drives; scalable; all ssd / nl sas components should be high endurance enterprise grade; the metadata based file type wise policy for data backup / movement should be provided. 1 disk hot spare every 30 disks. the metadata / object storage array should be separate for both storage. metadata / object storage should be redundant and with ssds only of suitable capacity as per solution requirement with minimum 90000 files / sec. , research cluster linux licence ( rhel or equivalent ) for proposed cluster , research cluster pcm professional cluster manager solution for proposed cluster perpetual licence with oem’s support for 5yrs , research cluster compiler : latest version of intel one api hpc toolkit ( 2 concurrent users ) with 5 yrs support from oem professional workload / scheduler solution perpetual licence with support , research cluster pbs pro schedular professional workload / scheduler solution for proposed cluster + 2 nodes perpetual licence with support for 5 yrs , research cluster linux mn ( rhel or equivalent ) for proposed cluster , virtual servers ( 1+1 redundancy ) : dual intel xeon gold 6326 16 core, 2.9 ghz; 512 gb ecc ddr4 ram in 100% balanced memory configuration ; latest windows data centre edition virtual environment with windows hyperv service; expandable shared 50 tb usable raid 5 / 6 ( 8+2 ) san storage ( 1 disk hot spare every 30 disks ) ; scalable with all the cables and interface cards to establish the connectivity with redundant host server. , display:at least 42 1080p / 4k led wall mount smart tv with hdmi & usb, 20 watts sound, x protection pro outside the data centre for monitoring & management. , wifi and lan : dedicated 1gige lan connectivity to each office seating space ( ~ 60 ports / users ) and other room. managed wifi connectivity for entire area ( ~ 100 concurrent users ) is to be installed in compliance with actrec it infrastructure. briefly, two dgs 1010p e switches and five ac1750 aps could be installed for this requirement. , software solution for comprehensive building, cluster, interconnect, network & data centre resource management , man power & support ( 1 system administrator for day to day administration of i.t. infra, container / tool installation / maintenance, web / ftp servers, back up scheduling etc. + 1 data centre management engineer ) , all in 3 shifts for 24 x 7 x 365 days support covered by oem / vendor for 5 years. actrec will advertise and select support staff on behalf of the vendor for hpc and cdc management and administration. experienced employees of the vendors could also be qualified for the interview based upon the experience. , computational data centre ( cdc ) turn key: any other work required for complete and all inclusive functioning of project considering turn key project should be described by the vendor. additional items included here should be justified and detailed at the time of submission. , amenities: projector, interactive display, wall art, plants, recreation room accessories etc as per the details in tender document , 5 years warranty is included in the above items. cmc rate ( hpc, cdc and other related work ) post 1 year warranty period will be fixed at 5% of the of the cost of the equipment for each year for up to two years without any escalation clause , total equipment and works cost :part – a: core infrastructure ( civil+electrical+hvac ) +part – b: hpc, cdc and other related work including cmc as applicable...