Central Railway - Maharashtra

36278384 supply of duct flexibleduct flexible,duct flexible emd drg. no. 9540362 alt. a dlw pt.no.17270730, i mark & packing conditions to blw spec no misc 456. [ warranty period: 30 months after the date of delivery] => limited...

Central Railway - Maharashtra

34985661 supply of duct air flexibleduct air flexible, duct air flexible to emd part no 40045237 . material to be provided along with gc and wtc...

Central Railway - Maharashtra

34543800 supply of duct air flexibleduct air flexible, duct air flexible to emd part no 40045237 . material to be provided along with gc and wtc...

Pimpri Chinchwad Municipal Corporation - Maharashtra

33735376 e quotations from experienced agency/manufacture or authorized dealer/distributors for work mentioned in abstract by executive engineer (e/m), g zone office, pimpri chinchwad municipal corporation mechanical ventilation 1 factory made tdf gi ducting 24 gauge 0.6mm thickness jindal make sheet 120 gsm, complete with flexible duct, ms supporting & hardware etc.. as per our drawing. 2 aluminium linear grill with powder coated without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 0/15/30/45 degree. (note minimum 1sqft. will be considered for items smaller than 1sqft.) 3 aluminium coller damper with powder coated for linear grills. (note minimum 1sqft. will be considered for items smaller than 1sqft.) 4 volume control damper manually operated, opposide blade, duct mounted of required sizes with operating mechanism, mounting arrangement, rubber refrigerant kits, etc.. (note minimum 1sqft. will be considered for items smaller than 1sqft.) 5 inline fan without cabinet 120 cfm / 13mm static pressure for exhaust/fresh air fan, steel mounting frame, vibration mounts, fire retardant flexible/canvas connection. 6 inline fan without cabinet 240 cfm / 16mm static pressure for exhaust/fresh air fan, steel mounting frame, vibration mounts, fire retardant flexible/canvas connection. 7 inline fan without cabinet 730 cfm / 20mm static pressure for exhaust/fresh air fan, steel mounting frame, vibration mounts, fire retardant flexible/canvas connection. 8 inline fan with cabinet 1380 cfm / 32mm static pressure for exhaust/fresh air fan, steel mounting frame, vibration mounts, fire retardant flexible/canvas connection. 9 inline fan with cabinet 1680 cfm / 40mm static pressure for exhaust/fresh air fan, steel mounting frame, vibration mounts, fire retardant flexible/canvas connection. 10 factory made gi cawl rectangular/round shaped 20 gauge 1mm thickness jindal make sheet 120 gsm with 25 x 25 x 3mm ms angle frame, bird metal mesh complete with hardware etc.. suitable for exhaust/fresh air fan of as per requirement. fire alarm system 11 supplying and erecting analogue addressable networkable & wireless 1 loop panel with battry, each loop capable of taking 65 detectors and devices (only honeywell / morlay/gst make). 12 supplying and erecting honeywell/morley/gst make wireless smoke detector.kitchen exhaust system 13 wall mounted hood made out of 20 gave, 1mm thickness, grade ss 202, sheet with all oil collecting greeze filters 14 supply, installation, commissioning & testing of 960 cfm 3.3 iwg esp exhaust/fresh fans in accordance with and meeting the intents & specifications, drawings and data sheets complete with: i) centrifugal fan with dual speed drive motors , as specified. ii) steel mounting frame iii) vibration mounts. iv) fire retardant flex. connections. v) epoxy coated cabinet. vi) isolator panel (ip 56) with starter panel with all accessories including cable from supply panel as required vii) with canvas connection viii) ms stand with vibration mounts...

Tata Memorial Centre - Maharashtra

32233733 engineering, procurement, supply, installation, testing and commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , cat ( a ) turnkey works required forengineering, procurement, supply, installation, testing & commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , civil work , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 80mm with riser panel arrangement ( including prefilter, damper & riser grill all clean room compliant ) wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 50mm with riser panel arrangement wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin totally flush walkable false ceiling made of 0.8mm thick powder coated sheets on both sides withpuf of density 40 ± 2 kg / m³ as infill, gi profiles for reinforcement along the periphery, including ceiling gridfor easy installation and necessary hardware. joints shall be sealed with cleanroom compatible silicon sealant. ( load bearing capacity 150 kg / m2 ) the thickness of panel shall 50mm as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. factory made cut out to be made in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. curvature radius : r 70 type. joint to be sealed with cleanroom compatible sealant. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor.3d internal / external corner coves. joint to be sealed with cleanroom compatible sealant. , providing and fixing flush doors 35mm thick with 1.0 mm laminates on both sides. the item includes teakwood chaukhat ( frame ) made from 75x50 teakwood. the door to have 12mm teak wood lipping on edges. the door is to be complete with cylindrical door lock , 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. coving in epoxy screed for wall to floor. joint to be sealed with cleanroom compatible sealant. , supply and installation of 46 mm thick doors made with pu painted 0.8mm thick gpsp sheets on both sides with puf as infill, 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures. alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , supply and installation of 46 mm thick emergency doors made with fire retardant paint having fire protective certification for 120mintues for door along with suitable infill to resist temperature upto 600 700 degree , alongwith 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures.alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , demolishing existing brick masonry and tiles with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry / rcc structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises and scope also include dismantling and careful removal of doors, distribution panel and storing and stacking complete all as directed by the engineer in charge. ( existing toilets, guard room & record room & ground floor & all areas wherever required for converting ward to cgmp facility ) . the scope also includes cleaning of flooring and scraping, levelling for application of self levelling epoxy coat for flooring. , dismantling of wash basin and removing of wall tiles and all the allied stonework and pipes & fittings wherever necessary and disposal of unserviceable material carting away the debris out of hospital premises or handing over the same to engineer in charge , providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle size 600mm center to center, lock and stopper etc. included in the item rate ) .as approved by engineer incharge. , providing and fixing panic bar / latch ( double point ) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the engineer in charge, all complete. , providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminium sheet having electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing and applying 3mm to 4 mm thick self levelling epoxy flooring system which consist of surface preparation, by grinding the surface , minor repairs if any, applying 1coat of epoxy primer , laying self levelling epoxy screed followed by top coat of self levelling epoxy coat as per manufacturer specification , work inclusive of existing flooring reparing and wall crack filling complete job as directed by eic. , applying 1 2mm thick birla white wall putty followed by final coat of epoxy wall painting wherever required as per the instruction of engineer incharge. , providing and applying and levelling the existing surface with birla white cement based / coloured waterproof putti of average thickness of 2 mm of approved thickness, brand and manufacture, over the plastered wall surface to prepare the surface even and smooth ready for painting purpose etc complete ( rate inclusive of scaffolding matetrial, labour charges ) etc. , providing and applyingacrylic ( premium ) emulsion paint of approvedmakeandshadeonwallswithsand papering& cleaning the surface, applying one coat of primer and lambi / puttytofullsurface3times, thereafterpaintingthe surfaceintwo coatsoverbaseprimercoattoachieveeven finish. rate is inclusive of all double scaffolding, all material and cleaning as per manufactures standard application method & specification etc. complete. , extra cost for projected return air riser panel made of 0.8mm thick powder coated sheets with 150mm projection above the ceiling and flange for fixing duct, with provision for fixing ra grill and filter etc. , gipc perforated grill for return air riser grill of 1.2mm thick with capsulation perforations for return with all necessary fixing arrangements. , supply and installation of 10 micron pre filter for return air riser ( 1000 x 500 mm ) as per the instruction of engineer in charge. , factory made cutout in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , providing and fixing of pvc conduit 32 mm in the wall panels , factory made cut outs with concealed in wall panel for electrical sockets, switch boards, mgs, etc. , providing & laying poly vinyl chloride ( pvc ) rolls flooringmanufactured of approved make and approved pattern for flooring, skirting / dadolaid on existing cement tile or concrete of plastered floor finish with suitable adhesive as per manufacturers specifications closejointed and finished to proper bends, slopes and plumbs asdirected etc. complete generally as per manufacturer’s specifications. providing & laying new2mm thck pvc flooring tiles. , toughened lacquered glass panelling: providing and fixing of 6mm thick toughened glass ( premium griha rated lacquered glass from glass manufacturer ) of approved colour by doit&c, mounted on clip ( j / j1 / i type ) or equivalent on a perfectly levelled surface ( granite cladded pedestal ) . lacquered strong glass must be made industrially ( via curtain coating process ) ; opaque ( if viewed against a support wall ) , coated with pu lacquer ( 100 micron thick ) ; colour consistency ( measured by spectrophotometer cm5081 ) ; highly durable ( passes persoz hardness test for minimum 220 oscillations ) ; humid resistant ( conforms to bs en 1036 1999 ) ; environmentally friendly ( no lead, no arsenic, no copper, no formaldehyde ) ; appropriate recycled content ( 12% post industrial / 6% post consumer ) ; compressive strength ( 1000 mpa ) & tensile strength ( 40 mpa ) , same as float glass. tempering should be done as the en 12150. glasses are to be fixed with polymer clips ( single sided j1 & j2 type, double sided i type ) , white backing foam and grey impact absorbing foam; to accommodate upto ± 10mm substrate undulation, and with a horizontal load capacity of 30kg / 100mm and vertical pullout load > 200kg / 100mm, glass should be supported with 1mm thick lip covering upto 3mm of glass surface; clips should be fixed using durable, non corrosive, strong s.s.screw 45mm long. all wooden material to be used shall be anti termite treated. the measurement only for the portion covered by glass to be considered. , granite cladded pedestal made from 200mm thick aac single block masonary including providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut on the blockwork with 1:4 cement mortar on all sides. including resting provision for glass panelling / partition. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge. , dismantling, breaking and cutting of slab by mechanical means i.e by using diamond cutter / sawing machine without causing damage to any beams and columns and lowering the cut pieces of concrete using chain pulley block on the respective lower floor level and handling the cut pieces including cutting it in smaller pieces and stacking / dispose the debris inside the campus as per the instruction of engineer incharge. item includes floor breaking and dismantling. , cutting of tiles and removing mortar for placement of electrical conduits in the floor and then covering the cement grouting flushed at floor level. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge excluding cost of electrical conduits. , structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and painting, including welding, bolting fixing with labour and material all complete. , providing metal roofing sheets manufactured from zinc / aluminum alloy colour coated fromn high tensile steel minimum yield strength 550 mpa; total coated thickness0.60 mm. profile and colour as approved by the architect ; generally as per durashine brand marketed by tata bluescope steel or equivalent including fixing as per manufacturers recommendations and includingflashings and accessories such as ridges, corner flashings, end flashings and galvanised fasteners from reputedmanufacturers such as mark fasteners. for correct levelling and alignment of sheets height of purlin tops shall be adjusted as provided in purlin connections. mode of measurements: plain area in the inclined plane of sheets shall be measured. nothing extra shall be added for collugations, profile, side laps, end laps etc. , supply and installation of double glazed view panels embedded in the clean room wall partitions with flush design fixed with 6mm thick toughened glass and necessary accessories. , window modification as per the instruction of engineer incharge. , dismantling of existing fire fighting system as per the instructoin of engineer incharge , providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building / structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia m.s. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with m.s. tubes, m.s. tube challis, m.s. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. the scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of engineer in charge. note: ( 1 ) the elevational area of the scaffolding shall be measured for payment purpose. ( 2 ) the payment will be made once only for execution of all items for such works. , providing and laying in position ready mixed m15 grade plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of r.m.c. from transit mixer to site of laying and curing, including the cost of centering, scaffolding, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the engineerin charge. ( m15 grade at all locations upto plinth level ) , providing and laying in position ready mixed m 25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of r.m.c. from transit mixer to site of laying, including the cost of centering, scaffolding, shuttering, finishing, including cost of admixturesin recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability and including supply and installation ofpvc water stopper as per direction of the engineer in charge at all levels. , providing and fixing of reinforcement steel including material fabricating, trasporting, loading, unloading, storing on raised steel rack platform, handling, straightening, cutting to length, bending, making hooked ends, hoisting into place at all levels and heights and binding in position ( including providing & using 18 gauge binding wire ) reinforcement bars of all diameters ( is 1786 , fe 500 of all grade ) to shape and size as per approved bar bending schedules and structural drgs. for all kinds of works at all heights & depths as specified including cost of approved quality pvc / concrete cover blocks, spacers, chairs at regular interval as per relevant is code and such other works that are required to make it complete.quantity of steel as per drawing, approved bbs and with authorized overlaps only shall be measured and paid for. quantity for chairs and spacer bars will not be paid. the measurement shall be as per is 1200 and reinforcement hooks and bends shall comply with the requirement of is 2502 unless clearly specified above. , aluminum partition workproviding & fixing alumimium partitionto the requiredheight partly glazed and partly panneledusing anodized aluminium section with satin finish anodizing of required size for bottom, top, middle &vertical rails at required intervals panneling with 12mm thickboth side pre laminatd board fixed with sloping aluminium beeding alround with neoprine gasket glazing with 5.5mm plain glass of approved make fixed withalumimium channel beeding two way pvc lining / rubber gasket to ensure water tightness and including providing necessary cover mould using suitable alumimium section so as to take care of gaps between the walls / ceiling / flooring and partitions etc. including providing and fixing necessary fittings as specified and directed. , aluminum sliding door providing and fixing sliding door to consist of partly glazed and partly panneled with using 5.5mm thick glass sheet of approved make and quality plain glass of approved make fixed with anodized aluminium sloping channel beeding with two way pvc lining / rubber gasket to ensure water tightness and panneling with 12mm thick nosva pan or ancholam board prelamimated board rated on both side as required, guiding rail section, vertical rails section includingproviding pvc guidrails of six 12mmx75mmas required at size concealed type locking arrangement and heavy duty handle set as per requirement including providing & fixing of18mm thick commercial ply with approved laminate of 1.5mm thick and teak wood lipping patti and non laminated surfaces should be polished with approved french polish at requiredshade & colour. , excavation mechanically ( using excavators like jcb / poclain / with bucket ) in all types of soil, including murrum, soft rockfor foundations, wall, columns, plinth beams, basement, raft, ducts, trenches, underground sumps, septic tanks, soak well including shoring and strutting, bailing out water / pumping off water if required, removing and stacking or disposing simultaneously the excavated soilanywhere within the actrec campus and / or spreading soils in layers for site development. all complete as per specification and as directed by the engineer incharge. for depth upto 1.5m. , removal and stacking of paver blocks taking out existing cc interlocking paver blocks from footpath / central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of engineer in charge. , dry stone rubble soling / pitching of 230 250mm size shall be approved quality, hard, free from cracks, durable, preferably black trap. rubble shall be laid on leveled base close to give compact, surface. if base is not properly leveledsame will have to be done without any extra cost. voids in the joints shall be filled with selected chips. a sample of paving shall be prepared and got approved before proceeding ahead. after stones are laid with thickness of 200mm and packed with chips, sandshall be spread and watered to fill remaining voids. sandshall be allowed to go into joints till final packing is obtained. rate quoted shall be for materials, labour, watering, leveling site, before paving, consolidating etc. complete. , providing & fixing soap dispenser metallic bottle. , p&f soap dish holder. , providing & fixing toilet paper holder with flap recessed type ( stainless steel ) . , p&f stainless steel surface mounted sanitary napkin disposal ( with flap ) of approved quality / make. cabinet 18 8, type 304, stainless steel size 270mm ( l ) x 105mm ( w ) x 385mm ( d ) capacity: 4.6 litres equipped with full length stainless steel piano flap , paper towel dispenser. cabinet 18 8, type 304, size 265x90x365 stainless steel finish: stainless steel satin capacity: 450 c fold, 600 multifold , p & f stainless steel hand dryer of approved quality / make. casing:stainless steel # 304 non magnetic, matt finish mounting :wall mounted operation :touch free infra red activation sensor range : 12 cm 15 cm hand dry time :less than 20 secs auto cutoff: 30 seconds motor:brush type, dual ball bearings speed:25, 000 rpm rated power :550 w ( no heating element ) current:2.5 a protection class :ip x 1 blowing volume : > 270 m3 / h air speed:95 m / s ( with speed controller ) , modular cubicle based restrooms of stainless steel make with stainless steel hardware with locking arrangement and 1 spare lock each.handles and hinges to be included in the rate. measurement per cubicle. , p & f 1st quality wvc urinal ( is:2556 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc. complete. cera cat no: s4010101 efs or equivalent , p & f 12mm thick toughened glass urinal partition with all type fitting. ( partition size 300mm x 1050 ) , providing & laying cast in situ rcc m25 grade of concrete. reinforced cement concrete: ( rcc ) reinforced cement concrete of m25 grade using graded stone aggregate of 20mm max. size including consolidation with vibrator & needle of required capacity finishing curing including form work, shuttering and steel reinforcement etc. complete all as directed by the engineer in charge. , a ) . columns ( rmc ) , a ) . lintel & tie beams ( rmc ) , b ) . sunshades ( rmc ) , reinforcement: reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the engineer in charge. ( laps will not be measured ) . with high yield strength deformed bars ( tmt bars ) & ms round bars , providing and fixing of steel shuttering wherever required as per the instruction of engineer incharge , brick work: brick work at all floor level with cement mortar 1:4 using well burnt locally available bricks of approved quality including scaffolding, raking out joints above ground level simultaneous and as directed by engineer in charge. in foundation & plinth drain walls chambers & superstructure of all floor levels , providing & laying of 20mm thk. external wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & laying of 20mm thk. internal wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & applying of 2 coats of apex weatherproof paint alongwith one coat of primer to the out side plastered surfaces. , providing & applying of oil bound distemper to theinside plastered surfaces , providing & laying of cc flooring ( 50mm thk ) as per the instruction of engineer incharge. , aluminum openable windows providing & fixing in position aluminium openable window shutter with frame fully glazed / aluminium grills withusing 5.5mm thick glass sheet of approved make and qualityplain / frusted / bajari glass of approved make fixed with aluminium beedingchannels with two way rubber gasket / pvc lining to ensurewater tightness and nos rattling for aluminium grill fixing with fchannel beeding using satin finish anosdized 15 micron jindalsectionsfor shutters and frameof required size and sectionincluding using aluminium / s.s. hinges of required size, tower bolt of required size, c type alum handle for shutterand othernecessary hardware as per requirement etc. complete all asper specified and directed by engineer in charge. the sections should be anodised. , labour charges for alum works : removing the existing partitions / doors and handing over the same at required place anywhere inside the actrec campus as indicated by the engineer in charge. etc. complete. , c.p.v.c. pipes:providing, laying, jointing, fitting, testing heavy quality c.p.v.c. pipes of required dia including all fittings including all brass fixtures such mt and ft required as per site requirement & laying the same at any floor levels including scaffolding all jointing materials & clamping in wooden blocks if required etc. complete as directed & specified by engineer in charge. , 15mm , 20mm , 25mm , 50mm , vetrified dado tiles providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete as per the instruction of engineer incharge. , vetrified floor tiles: providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete. , e.w.c.:providing and fixing white vitreous china pedestaltype water closet ( european type w.c. pan ) with seatand lid, level white p.v.c. flushing cistern with capacity as mentioned below, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittingsand fixtures complete including cutting and makinggood the walls and floors wherever required. it should include p or s trap as per approved make with left or right vent in position including fixing it on chair brakcet or wall bracket. with necessary c.p. brass screws & plugs etc.floor mounted ewc universal with 5 to 7 ltrs cistern:special colour as per instruction , pressmatic taps :urinal valve auto closing system with built in control cock with wall flange . providing and fixing including removal of existing if any as per the instruction of eic , granite: providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut for kitchen / toiletplatforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) with joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels of colour black / red / grey etc. , providing and laying water proofing treatment of average 100 mm thick for sunk slabs of toilets and wherever necessary at all the levels with brick / stone aggregates, with layer of 20 mm thickcement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with water proofing compound as specified by the manufacturer, layingbrick bats of required size impregnating in to the base mortar bed with gap of 12 mm all aroundaccording to slope, level and curing the same, the gaps around brick bats filled with cement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with waterproofing compound, 20 30 mm layer above brick bats and finishing top with neat cement @ 2.75 kg / sq.m. screeding and curing etc. in line, level and plumb / slope, complete including furnishing of guarantee for 10 years. ( note : the above rates shall be inclusive of providing and mixing of waterproofing compound as per manufacturers specifications ) , fancy pillar tap: providing & fixing approved make heavy quality c.p.brass screw down pillar tap long nose not less than 810gm. with jam nut easy clean variety of 15 mm n.b. etc. complete all as directed by the engineer in charge , nahani trap: providing & fixing 100mm dia c.i heavy duty nahani trapwith bras c.p. dome type heavy duty s.s. jali all as approved make quality as specified and directed by engineer in charge one way / two way need concrete joints.extra if required , water shower moc ss 304 with all necessary arrangements . , overall size ( 2450 x 2000 x 2000 ) mm. , pass box dynamic dynamic pass box , made out of ss 304 with no 4 finish. should have 600 mm ( h ) , 600mm ( w ) and 600 mm ( l ) internal sizes , supply of ss wall bench bench with ss sink and sensor tap of size 750l x750w x900mmh as per the layout drawing consists of moc: ss 304sheet finish: no4 mat under bench storage module having450x450x180 ss sink sensor one way tap shutters and accessories likesshinges, , ss d handlesetc., pedestal with adjustment set and 25 mm double skin puf infilled top , drain collection tank with weighing scale: , supply of emergency eye wash shower moc ss 304 , electrical work , dg set supply , installation, testing & commisioning of diesel generating ( d.g. ) set with class g3 governing ( 40% step load ) , alternator of 625 kva output at 0.8 pf continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 v, 50c / s, radiator cooled, multi cylinder diesel engine at 1500 rpm , seperately excited amg having class h, spdp alternator ( with battery charging generator ) , with static avr + / 1% & thd<3%, running at 1500 rpm. both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having engine & generator protection ( including ref & rpr ) / parameter display / operator interface / power command 3.3 control system / amf panel / synchronization / dedicated earthing system / rs 485 modbus connectivity, etc. the complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 db at 1 meter, made of 16 / 14 swg crca sheet, complete with first filling of lube oil / diesel / coolant & fuel hoses, battery, 990 liter external fuel tank, residential silencers, mounted on plinth & obtaining necessary approval from electrical inspector. a ) exhaust piping to be raised upto terace level of nearest building. b ) power / control cabling, terminations, etc. c ) 990 ltr. capacity external deisel tank.d ) . height of stack to be maintained as= height of building + 0.2 * vkva . e ) factory testing to be carried out in present of actrec engineering before despatch of equipments. , 625 kva dg set , amf panelsuitable for 625 kva diesel generating set with battery charger and standard accessories. , ms class ‘b’ diesel engine exhaust pipe of suitable size ( including all fittings, clamps, steel support ) of suitable dia for the engine. the pipe shall be provided with 12 mm thick ceramicfibre rope and below to be insulated with cloth and glass wool. , supply & installation of exhaust pipe thermal insulation and cladding. , installation of silencer , supply & installation of silencer thermal insulation and cladding , supply & installation of m.s. supports for exhaust pipe & exhaust structure suitable for 1 x 200 mm exhaust pipe ( structure height 25 mtrs ) including standar panel & tray , supply & installation of s.s. bellows 200 mm with matching flanges, gaskets and fasteners , ups 3 phase in 3 phase out with igbt pwm based rectifier technology with isolation transformer ac input voltage:415 v + / 10% , frequency:50 hz + / 5%, output voltage:415v + / 2% , output frequency:50hz + / 0.5%, efficiency: 0.9. type of battery:smf, battery capacity: for a backup time of as specified, battery charging current:shall be calculate for unity power factor. protection: electronic over voltage trip, electronic under voltage trip, single phase prevention, overload, short circuit and battery overcharge, indications: ac on, inverter on charger fuse, inverter trip. one number rs232 ports to steady the data with all accessories complete etc., , 160kva online ups with isolation transformer 3 phase i / p and 3 phase o / p with 30minutes backup. , sealed maintenance free batteryof 34nos, 12v / 130ah, 30minutes backup. , battery rack with accessories for 160kva ups. , lv panels free standing, floor mounted mcc panel made out of 2mm thick crca sheet duly powder coated after seven tank process consisting of suitable rating incomer, aluminum bus bar supported with dmc / smc barriers & color coded with heat shrinkable sleeves, metering and outgoing feeders ( as mentioned against each panel ) : , mcc panel 1 for ahu 1, 2, 3, 4, 5, 6, 7, 8 ahu for exhaust 2 nos, mcc 2, ups, ldb 1, pdb 1&2 ( as per enclosed sld ) . , mcc panel 02 for air cooled chiller 1, 2 &3 chilled water pump 1, 2, 3, 4, 5, hot water generator 1, hot water generator 2, hot water pump 1, hot water pump 2. ( as per enclosed sld ) , ups panel for eldb 1 , epdb 1 , epdb 2 & epdb 3. ( as per enclosed sld ) , lv ( power & control ) cables 1.1kv grade xlpe / pvc insulated aluminum / copper multi strand conductor steel armoured cables. , 3.5c x300mm² al. armd. xlpe insulated cable. , excavation and cable layoing and backfilling as per the iso norms , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable. , 3.5c x 25mm² al. armd. xlpe insulated cable. , 4 c x 4mm² cu. armd. xlpe insulated cable. , 4 c x 2.5mm² cu. armd. xlpe insulated cable. , 3 c x 6mm² cu. armd. xlpe insulated cable. , 3 c x 4mm² cu. armd. xlpe insulated cable. , 3 c x 2.5mm² cu. armd. xlpe insulated cable. , 1c x35mm² cu. unarmd. xlpe insulated cable. , 1c x70mm² cu. unarmd. xlpe insulated cable. , lv cable end terminations termination of cables with brass double compression glands including cost of crimping lugs / ferrules, solder, cable sockets, insulation tapes etc. , 3.5c x300mm² al. armd. xlpe insulated cable. , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable terminations. , 3.5c x 25mm² al. armd. xlpe insulated cable terminations. , 4 c x 4mm² cu. armd. xlpe insulated cable terminations. , 4 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 3 c x 6mm² cu. armd. xlpe insulated cable terminations. , 3 c x 4mm² cu. armd. xlpe insulated cable terminations. , 3 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 1c x35mm² cu. unarmd. xlpe insulated cable terminations. , 1c x70mm² cu. unarmd. xlpe insulated cable terminations. , earthing supply, installation testing of earthing station as per is standard complete with 600x600x6mm gi plate electrode, salt, charcoal, 2 nos. 50x6 mm aluminum strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm gi strip. , 25x3mm gi strip. , 6mm² single core multi strand wire ( green color ) . , 10mm² single core multi strand wire ( green color ) . , supply, installation testing of earthing station as per is standard complete with 600x600x3mm copper plate electrode, salt, charcoal, 2 nos. 50x6 mm copper strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm copper strip. , 25x3mm copper strip. , 2000mmx1000mmx12mm corriguated rubber mats, as per standards. , d.c.p. type fire extinguisher for following capacity cartridge type with gun metal cap 150gram co2 gas cartridge, powder and brackets confirming to is 2171 19885 andcompleted erected with necessary clamps made from 50 x 6mm. ms flat with nut & bolts grouted in wallcomplete. 6kg capacity. , carbon dioxide ( co2 ) fire extinguisher user of following capacity with necessary clamps made from 50 x 6mmm.s. flat with nut & bolts grouted in wall complete. 4.5 kg capacity. , mcb distribution boards : , 12way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 12 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 8way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 8 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 1 phase, 8 way lighting distribution board with horizontal double door type40a dp el mcbas a incomer, 6nos. 6 10a sp mcb as a outgoing circuit. mcb shall be provided with “c” curve , 3 phase , 12 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a dp mcb per phase& 30 nos. 16a / 20a sp mcbin outgoing circuit . ( 10 nos, mcb per phase ) ( pdb ) . mcb shall be provided with “c” curve , 3 phase , 8 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a, 300ma, dp elcb per phase& 18 nos. 16a / 20a sp mcbin outgoing circuit . ( 8 nos, mcb per phase ) ( pdb ) .mcb shall be provided with “c” curve , modular & industrial type switch sockets switch socket industrial type industrial pentra type socket & plug with mcb enclosed in enclosure. the scope includes fixing of enclosures , supply of all fixing accessories / hardware. mcb and socket shall be wired up upto outgoing terminals etc, complete as required. , single phase 25 amp 3 pin socket with straight connected plugwith 25 amp dp mcb. , single phase 32 amp 3 pin socket with straight connected plugwith 32 amp dp mcb. , three phase 32 amp 5 pin socket with straight connected plugwith 32 amp fp mcb. , modular type switch / sockets / lan / telephone system the crca modular box shall be concealed in such way that front plate flush withmodular partition wall and& brick wall front plate shall be ss 304 matt finish. , 16 amp switch 1 nos. with modular box, front & rear plate. , 16 amp switch 2 nos. with modular box front & rear plate. , 16 amp switch 3 nos. with modular box front& rear plate. , 6 / 16 amp switch socket 1 no. with modular box front & rear plate. , 6 / 16 amp switch socket 2 no. with modular box front & rear plate. , rj45 lan socket 1 nos. with modular box front & rear plate. , rj11 lan socket 1 nos. with modular box front & rear plate. , rj45 socketeach 1 nos. with modular box front & rear plate. , cat 6 flexible cable. , 50 pair telephone junction box , 12u rack with 4 nos. 24 port patch panel with all accessaries. , wi fi network point with all accessaries. , 50 pair telephone cable , ip telephone instrument , analogue telephone instrument , supplying and fixing 1 meter length, utp patch cord of cat 6 type in position as per requirement. , supplying and fixing 7 ft length, utp patch cord of cat 6 type in position as per requirement for end point device ( pc / laptop etc ) , sitc of lazr speed 300 fiber, 6 core indoor application, multimode, to be laid through conduit and flexible with all the connectors, couplers, pigtels, lius at both endcrca module box , the crca module box shall be concealed / surface mounted on brick wall / modular partion. , light fixtures , 42w led bottom openable type cleanroom light fixtutre. , 20w led bottom openable type cleanroom light fixtutre. , 39 / 40w led batten type light fixtures. , 1.1 kv, grade frls, pvc insulated multi strand copper flexible cables , 3c x 1.5mm² cu. flexible cable. , 3c x 2.5mm² cu. flexible cable. , 3c x 4mm² cu. flexible cable. , 3c x 6mm² cu. flexible cable. , 5c x 6mm² cu. flexible cable. , 3c x 10mm² cu. flexible cable. , flexible cable terminations including crimping lugs / ferrules etc. complete as required , 3c x 1.5mm² cu. flexible cable terminations. , 3c x 2.5mm² cu. flexible cable terminations. , 3c x 4mm² cu. flexible cable terminations. , 5c x 6mm² cu. flexible cable terminations. , 3c x 10mm² cu. flexible cable terminations. , supply and installation of gi perforated & ladder cable trays : hot dipped galvanized and minimum thickness of hot dip coating is 70 to 100 microns. thickness of cable tray sheet steel for 50 mm to 300 mm cable tray 2.0mm thickminimum height of the perforated cable tray is 30mm or 50mm. cable tray shall be in different widths and shall be in standard length 2500mm long and suitable to couple two cable trays with coupler. support required for fixing the cable trays considered in the structural steel , 50mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 100mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 150mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 300mm ( w ) x 50 mm ( h x 2mm thinkness perforated cable tray. , 450mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 600mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , structural steel for supports. , pvc conduit with bends, junction boxes, and all necessary accessories and hard ware as following. , 25 mm pvc conduit. , pvc flexible conduit with clamps and all necessary accessories and hard ware as following. , 25 mm flexible conduit. , ceiling fan , 1200mm sweep ceiling fan , bms system software , bms software: graphical user interface software based on ms windows with1000 points & 1 client license .the system should be accessible from anywhere on lanor ethernet . the communication protocol shall be bacnet protocols . system should be scalable in all levels , eggineer and user level passwords. , bms client station:intel i7 3rd generation processor 3ghz, with 1tb x 2nos hard disk, 16 gb ram / dvd rw / keyboard / optical mouse / lan card / 32” led monitor. minimum 4 usb ports. with pre loaded licensed windows 10 professional software ( latest version ) , ms office and anti virus, dual 2gb graphic cards as per tender specification. , server pc: the main servers will be intel xeon processor e5 2600, minimum speed of 2.3 ghz with 6 core, dual gigabit ethernet port, usb port, video port. the server memory will be 16 gb ddr4 ram with 21 inch monitor , laser printer for alarms and reports a4 size ( black & white ) , ddc panels ip based ddc controllers with in built real time clock, 32 bit micro processor cpu, memory, enclosed in ms powder coated enclosureas per io summary , ddc 1&2 ( ahu 1, aeu 1 & ahu 6, aeu 6 ) with io points ofai 26, di 24, ao 10 & do 08 , ddc 3&4 ( ahu 2, 3 & ahu 4, 5 ) with io points of ai 22, di 14, ao 08 & do 04 , ddc 5 for emswith io points of ai 62 , di 0, ao 18 & do 0 , gatewaymodule for integrating the third party systems communicating on one of the standard open protocols such as bacnetand modbus, etc with bms , chiller intigration, energy meters, hot water generator , field instruments testing and commissioning of following instruments with required accessories , dp switch across fan to monitor filter clog status monitoring ( fine filter ) range: max 1000 pa , differential pressure switch for ahu run status range: max 500 pa , duct dp transmitter across fan , room temp, rh & dp display unit with inbuilt dp and external temp & rh transmitter , static pressure senosr for vfd speed , duct mount temperature & rh sensor with temp accuracy: ±2% & rh accuracy: ±3% , damper actuators , room temperature & rh , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 4c x 1 sq mm armoured copper shielded cable , 2c x 1 sq mm armoured copper shielded cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 8 port network switch with rack , validation & documentation : thevalidation to be done after the validation & commisisoning of the facility , validation and commissioning of entire facility including the qualification and operational approach ( protocols for sat and iq and oq, or ioq ) .validation of the bms system with related qualification documents dq / iq / oq / pq as per international norms and client standards. , fire alarm system , addressable2 loop fire alarm control panel ( facp ) with battery charger and with the battery back up for 8 hours normal operation and one hour alarm operation.the facp shall be expandable upto 10 loop. the facp shall include a full featured operator interface control and annunciation panel that shall include a backlit 640 character liquid crystal display, and a qwerty style alphanumeric keypad for the field programming and control of the fire alarm system.system should support upto 159 detectors and 159 modules in one loop. the panel shall be ul listedand fm approved and comply ul 864, 9th edition requirement. the enclosure shall also be ul listed. the quoted rate shall include supply of necessary software and harware for progamming the panel with all necessary licence. ( with fiber support ) , intelligent analog addressable photothermal detector complete with mounting base complete as required. , intelligent analog addressable hest detector complete with mounting base complete as required. , manualcall point with address switch to programme the modules which monitors and reports contact status..complete as required as per technical specification. , addressable horn cum strobe complete as required. , analogue addressable control relay module for ahu tripping and shall bewith the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , should be capable of monitoring shorted loop circuit and automatically restore communications when shorted condi , analogue addressable control module shall be with the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , active repeater panel with minimum 640 character backlight lcd display with qwerty keypad and fixed function keys and soft keys. it should have control and display capabilities for all nodes of the network. should have the facility to store 1000 alarm event & 4000 system events. the panel shall be ul listed and fm approved.complete as required as per technical specification. ( with fiber support ) , response indicator , 2c x1.5 mm², pvc insulated frls armoured copper cable for slc loop & power supply, confirming to is standards and specifications..complete as required as per technical specification. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , exit signages , 10a power supply unit , access control system , door access control system access control desktop pc with thefollowingminimumspecifications:intelcorei5, 3ghz, 4gbram, 500gb hdd, 32lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmi output, configurationwithwindows10 pro, office 12 and antivirus , access control system software , time attendance software system as per clients requirement. , access control system will be magnetic door type controlled through card readers and biometrically inncluding all accessories and with necessary cables and terminations. the system will be capable to record the biometric attendance of the authorized personnel and the records will be stored in server. magnetic lock and door sensor , emergency release switch in green polycabonate housing / push to break glass type , proximity cards complete as required , cat 6 cable , ethernet switch 16 channel , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , arrangement of interconnection between fire alarm system and access control system to automatically open the door in case fire emergency. , door interlock system , 2 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable end terminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , 3 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable endterminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , cctv system , professional grade network video management recorder, comprising 32ch. nvr to record output of all cameras mentioned above with 1920x1080p resolution @30fps, third party ip camera supported, h.264 compression up to5megapixelsresolutionrecording, multipleharddisksloteachhavingmaximumstoragecapacityof24tb, minimum of 30 days recording motion / continuous, 720p @ 25 fps recorded view, and 1920x1080p @30fps live view, 2 usb 2.0 or 3.0, httpnetworkable, backupbyusb / dvdwr, redundant backup of nvr scheme, included software, client licenses and required camera licenses complete as per technical specifications and as required. all the components to be of same make as camera. nvr shall be bis certified. , ip65dome network camera full hd 2 mega pixel low illumination lux 0.5 high sensitivity with 1 / 2 inch progressive image sensor, h.265+ video compression, 1920x1080 @ 20 fps with poe powersupported, onvif s profile, face detection etc, operating temp 10 to +40 degree c, certification bis approved. ( indoor application ) , networktdnirindooroutdoorbulletcamera1by3cmos1, 3mp3point6mmfixed24irledspoe h264, excellent low light performance with 3d noise reduction, saving storage and bandwidth together with h.264 high profile codec , 24portmanagedswitchwith poe / poe+, as required, i / c connections ofl3 switchwith 16port switchx 10 / 100 / 1000t poe ports and 4 x100 / 1000x sfp ports complete etc. as required , rj 45 connectors , closed wall mount rack 12u , led display monitor: the sufficient no. of full hd led monitors with high resolutions screen size of 52” ( diagonal ) are to be provided for viewing all live / recordedcameraproceedings.theresolutionsof1920 ( h ) x1080 ( v ) pixelswithcomfortableviewingangleis proposedforallmonitorssuitableforoperationon220 240vac50hzpowerforthedisplaypanelshouldbe equipped with all standard features such as video in, audio in, hdmi / dvi, rj 45 port etc. , cat 6 utp cable with accessories. , sitc of 3 core*1.5sqmm frls unarmoured power cable with all accessories complete as required. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , p.a. system , six zone voice controller with necessary interface to fire alarm system, and zonal configuration facility complete along with up to 255 pre recorded message, emg evacuation message , high quality 6 watt, 100vspeakers with box ringin ceilingmounted type with tansformer & terminations. , 6w volume control regulator , 250w amplifier , mixing amplifier , table top microphone. , equipment rack for pasystem unit with secure lock & key. , cd player for music source , 0.75sqmm twin twsted wires for speaker on cable tray or pre fixed conduits including terminations. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , e.m.s. system , standalone controller operator pc: pc with thefollowingminimumspecifications:intelcorei7, 3ghz, 4gbram, 500gb hdd, 32 lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmioutput, configurationwithwindows10 pro, office 12 and antivirus ( work station , operator station , one stand by as per spec ) , ems software , converter for intigration to ems systeam , 16 port ethernet switch with rack , 8 port ethernet switch with rack , smps , field instruments , room dp transmitter with three row display unit ( t&rh and dp ) , room temperature & rh transmitter , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 3c x 1.5 sq mm armoured copper cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for electrical items , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , hvac system , air cooled chiller units : supply , installation testing and commissioning of air cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; condenser coils as a mandatory requirement shall have a factory applied anti corrosive protective coating of electro deposited and baked flexible epoxy coating, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprene pad vibration isolators, integralrefrigerant piping and wiring, accessories as required and called for, automatic and safetycontrolsmountedincentralconsolepanelandailmountedonasteelframe.motorshallbesuitablefor 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a or equivalent ) . the noise level for each chiller should not exceed 80 dba at 1 meter, measured at any point from the chiller. inlet temp.of water 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceas permanufacturersdrawing.allms structurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price.microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection. note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. , capacity 60tr ( 2w + 1s ) chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , heat pump 150 kw ( 1w+1s ) , supply, installtion, testing and commissioning of water cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; water cooled condenser, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprenepadvibrationisolators, integral refrigerantpipingandwiring, accessoriesasrequiredandcalledfor, automatic and safety controls mounted in central console panel and ail mounted on a steel frame. motor shall be suitable for 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a / equivalent ) . thenoiselevelforeachchillershouldnot exceed80 dba, measuredat anypoint 1 metersfrom the chiller. hot waterinlettemperatureof450c, outlettemperatureofwater500c.chilledwaterinlettemp.ofwater 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceasper manufacturersdrawing.allmsstructurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expaansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price. microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection.note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. hot water inlet @ 45 deg c, outlet @ 50.0 deg c.chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , chilled / hot water pumps supply, installation, testing & commissioning of horizontal / verticle pumps. pump body : cast iron, impeller : stainless steel / aisi 316l. all pumps shall be aligned properly as required as per specifications.minimum efficiency of the pump shall be 75%. the pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply.the motor selected shall be energy efficient having efficiency ( class i ) at full load ranging between 91.5% to 94% in accordance with motor rating as per specification.vendor to check & confirm the motor ratings as specified for outdoor duty application consisting of: a ) pump and motor ( suitable for outdoor and continuous operation ) , b ) mounting frame & vibration isolators, c ) earthing of motor ( ip 55 ) & frame, d ) lifting & mounting of the pumps at locations as shown in drgs. ( at terrace level ) , e ) all accessories require i.e. flexibles, eccentric reducers and expanders, consumables etc., f ) insulation of the pumps and accessories as per the given specifications. , chilled water pumps , capacity:240usgpmhead 35m ( 1w +1s ) for air cooled chiller , capacity:106usgpmhead 35m ( 1w +1s ) for heat pump , hotwater pumps , capacity:180usgpmhead 35m ( 1w +1s ) , electrical panel for pumps for chilled and hot water supply installation and commissioning of electrical panel for pumps including:a ) logic controller with required software, b ) all mcbs, mccbs, vfds, vfd by pass etc as per require, c ) differential pressure sensors / transmitters with control wiring, d ) bms compatibility , electrical panel for pumps , control wiring between dpts and main controller / s , air separator supply , installation , testing and commissioning of 125 mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for chilled water with all assesories. , supply , installation , testing and commissioning of 100mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for hotwater with all assesories. , open type expansion tank supply , installation , testing and commissioning of 1000l ms tank with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding with make up water connection, over flow and drain provisions for chilled water with all necessary foundation , supply , installation , testing and commissioning of 1000l pvc tank with make up water connection, over flow and drain provisions for hotwater with all necessary foundation. , chilledwater piping: supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 150mm dia. ( 75 mm thick insulation ) , 125mm dia. ( 50mm thick insulation ) , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 65mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 32 mm dia ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , sitc of butterfly valves, required for chilled waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 125 mm ø , 100 mm ø , 80 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 40 mm ø , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , 80 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc fabricatedchilledwater manifoldfor ahus as below having chw requirement for chw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 100 mm ø , 50 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 80 mm ø , 40 mm ø , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 125 mm ø , 100 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hot water piping supplying, laying / fixing, testing and commissioning of following nominal sizes of hot water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , valves & instrumentssitc of butterfly valves, required for hot waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 80 mm ø , 50 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 50 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc fabricatedhotwater manifoldfor ahus as below having hw requirement for hw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 40 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 80 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hvac low side items air handling unit recirculation type ahu for classified systems ( iso 7 ) . sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 02 13260 cmh ( 7800 cfm ) with 11tr cooling & 26.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 03 16830 cmh ( 9900 cfm ) with 11tr cooling & 20.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 04 10200 cmh ( 6000 cfm ) with 9tr cooling & 12.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee section filter with flange type filter section with combination of eu 4, eu 5 filtersfilters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 01 6120 cmh ( 3600 cfm ) with 5.0tr cooling & 7.0kw heating capacity@ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 06 1700 cmh ( 1000 cfm ) with 2.0tr cooling & 3.0kw heating capacity @ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 07 11900 cmh ( 7000 cfm ) with 9.0tr cooling@ 100 sp with 2 motor ( 1 w+1s ) ( qa qc area ) , once through type ahu sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panelwith internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 05 13090 cmh ( 7700 cfm ) with 45tr cooling & 41.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , exhaust unit floor mounted horizontal type exhaust unit. sheet metal sectionalised cabinet type ahu in double skin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.63 mm gi & outer skin 0.63mm precoated giconstruction with 25mm thick puf insulation panel, suitable 20 micron filter, blower and motor, exhaust damper, vibration mounts etc with all necessary hardware. , veu 05 13430 cmh ( 7900 cfm ) @ 75sp motor: ( 1 w+1s ) , chilled water cassette / hi wall unit sitc of chilled water cassette unit withinfrared remote control, micro controller, drain pump & necessary supporting arrangement with ready made valve station complete with butterfly valves / gate valves , 2 way valves with actuators–strainer, pressure cum balancing valves. the entire skid shall be coated with zinc chromate primer coating and then painted with enamel paint.electrical cable connection from mcb / isolatorto cassette unitshall be done by hvac contractor. , 1.0tr ( cabin and passagearea ) , 3.0tr ( office area ) , decorative fcu: chilled water fan coil unit of double skin construction with compact cooling coil, multispeed fan motor, the blower shall be dynamicaly balanced and designed for silent operation, the filters shall be washable synthetic media type arranged for convenient cleaning and replacement, drain pan with pump . the actuator of modulating valve shall be provided with interface cards to receive 0 10v or 4 20 ma signal from minxon digital thermostat. unit complete with all necassary valves.the unit is supplied with corded remote controller of approved as per instruction and as directed by oic es , 2.0tr ( for ups and battery room ) ( 1w+1s ) , 1.0tr ( for storageroom ) , air filtration system hooded type hepa filters supply of hepa filter modules with ss 304 supplyperforated grill in crca powder coated finish side inlet type, with provision for dop, pressure drop measurement along with volume control damper and provision for a flange type hepa filters ( hepa filterh14 type ) including flexible connection. price also include the hepa filter. , size: 610 x 610 x150 mm , size: 450 x 450x150 mm , size: 305 x 305x150 mm , supply, installation, testing & commissioning of 25mm thick thermal insulated aluminium flexible duct of250mm dia duly supported at regular interval as per site requirement etc. complete as required as per specifications. , air distribution and control system ducting supply, fabrication, installation and testing of following sizes of aluminium metal ductingaluminium supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc. the frame shall slide over the duct ends to form flange connection. the flange connection shall be supplied with airtight seals. ducts shall be suitably reinforced using diagonal bends, distance pieces, etc.apermanentnon etching, siliconefreeelasticsealingmaterialshallbeused.exposed duct should have provide al. cladding.duct leak test to carry out after instalttion. , 22 g sheet , 20 g sheet , 18 g sheet , insulation , supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber ( class o ) insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. exposed duct should beprovide with 26 g al cladding. , 32 mm thick on supply air duct , 19 mm thick on return air duct , supply installation of aluminium extruded powder coatedvolume control damper constructed in 18g gi frame and 18g blades complete with handle for main and branch ducts. , al.sq.fourwaytypeairdiffuser ( supply&return ) with18g, g.i. powdercoatedboxwithaluminumcollar damper: , miscellaneousitems , fire damper: supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch and return air path as and where required of required sizes i / c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. , fire damper , actuator , supply grills , supplying & installtion of perorated type grill for return air riser with 1.2mm thick gipc capsulation perforations with all necessary fixing arrangement. , gi powder coated fresh air louvre with filterand brid screen , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the rooms , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the ahus. , on site validation and testing of the complete clean room system:after completion of e&c of all equipment and accessories, validation test shall be conducted as described below: testing & validation as per iso 14644:2001 standards ( velocity, particulate count, temp, humidity, filter, integrity tests to be carried out at the site ) by 3rd party. a comprehensive on site validation and certification service for clean room installation is in the scope. these includes leak detection, clean room level measurement and certification, air flow pattern analysis, dead zone identification and elimination and comprehensive documentation with regard to maintenance & validation procedure. , followingvalidation&testingoftheinstalledclean roomduringfinalcommissioningoftheabovecleanroom project: cleanliness levels as per iso 14644 air quality monitoring particle size efficiencies and quantity count airborne particulate contamination monitoring air velocity measurement & air flow quantity measurement temperature control range tests humidity control range tests filter pressure drop measurements air flow pattern and strength light level checks at 1m working height in clean room room pressurization , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for hvac system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , gas distribution system , supply and installtion of high pressure gas manifold system ( manual ) for four cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , sitc of automatic control panel to transfer co2 between the manifold. , supply and installtion of high pressure gas manifold system ( manual ) for two cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , 1 / 2 ss 316l tube with necessary fittings and supports ss 316l , 1 / 4 ss 316l tube with necessary fittings and supports ss 316l , 1 / 2 ball valvess 316l , 1 / 4 ball valve ss 316l , sitc of gas control box with gauge regulator, needle valveand all other necessary fillting, hadware etc as per the requirement. , sitc of pvc tube with brass nozzle for providing the connection inside the lab with all necassry hadware, fitting etc as per instruction and as directed by oic es , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for gas distribution system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , cat ( b ) supply, installation, testing and commissioning of following equipment as per tendered specifications of cgmp centre of cellular immunotherapies at actrec , lab refrigerator – 625 ltsas per tendered specifications , clean room lab refrigerator – 625 ltsas per tendered specifications , blood bank refrigerator customized 625 lts as per tendered specifications , automated closed cell processing system as per tendered specifications , cell expansion system as per tendered specifications , mobile processing system ready kart as per tendered specifications , controlled freeze system ( rate controlled freezer ) as per tendered specifications , blood bag centrifuge – 8 bags as per tendered specifications , water bath high precision as per tendered specifications , automated thawer for bags as per tendered specifications , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) as per tendered specifications , air jacketed co2 incubator as per tendered specifications , automated cell counter as per tendered specifications , inverted microscope as per tendered specifications , inverted microscope as per tendered specifications , floor model high speed centrifuge ( bags & vials ) as per tendered specifications , 100 ltr refrigerator as per tendered specifications , sterile connecting device type aas per tendered specifications , sterile connecting device type bas per tendered specifications , hand sealeras per tendered specifications , magnetic based cell separation system cts grade dynamagnet as per tendered specifications , bench top minispin as per tendered specifications , high performance centrifuge for elutriationas per tendered specifications , table top model high speed centrifuge as per tendered specifications , bsl cabinet ( bsl 2* ) as per tendered specifications , ultracentrifuge as per tendered specifications , bench top centrifuge as per tendered specifications , microplate spectrophotometer as per tendered specifications , real time pcr as per tendered specifications , gel dock system as per tendered specifications , end point pcr proflex as per tendered specifications , flow cytometer facs cell sorteranalyzer as per tendered specifications , endotoxin detection system as per tendered specifications , liquid nitrogen tank bags as per tendered specifications , liquid nitrogen tank vials as per tendered specifications , deep freezer 80 cas per tendered specifications , deep freezer 20 to 40 c as per tendered specifications , deep freezer 20 c as per tendered specifications , deep freezer 80 c as per tendered specifications , cryoshipper as per tendered specifications , cat ( c ) cmc after expiry of warranty period for following equipment , lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 1st year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 2nd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 3rd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 4th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 5th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 1st year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 2nd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 3rd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 4th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 5th year after expiry of warranty period of 2 years , cell expansion system cmc for 1st year after expiry of warranty period of 2 years , cell expansion system cmc for 2nd year after expiry of warranty period of 2 years , cell expansion system cmc for 3rd year after expiry of warranty period of 2 years , cell expansion system cmc for 4th year after expiry of warranty period of 2 years , cell expansion system cmc for 5th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 1st year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 2nd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 3rd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 4th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 5th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 1st year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 2nd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 3rd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 4th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 5th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 1st year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 2nd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 3rd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 4th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 5th year after expiry of warranty period of 2 years , water bath high precision cmc for 1st year after expiry of warranty period of 2 years , water bath high precision cmc for 2nd year after expiry of warranty period of 2 years , water bath high precision cmc for 3rd year after expiry of warranty period of 2 years , water bath high precision cmc for 4th year after expiry of warranty period of 2 years , water bath high precision cmc for 5th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 1st year after expiry of warranty period of 2 years , automated thawer for bags cmc for 2nd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 3rd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 4th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 1st year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 2nd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 3rd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 4th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 5th year after expiry of warranty period of 2 years , automated cell counter – 625 lts cmc for 1st year after expiry of warranty period of 2 years , automated cell counter cmc for 2nd year after expiry of warranty period of 2 years , automated cell counter cmc for 3rd year after expiry of warranty period of 2 years , automated cell counter cmc for 4th year after expiry of warranty period of 2 years , automated cell counter cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type a cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type b cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 5th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 1st year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 2nd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 3rd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 4th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 5th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 1st year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 2nd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 3rd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 4th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 5th year after expiry of warranty period of 2 years , hand sealer cmc for 1st year after expiry of warranty period of 2 years , hand sealer cmc for 2nd year after expiry of warranty period of 2 years , hand sealer cmc for 3rd year after expiry of warranty period of 2 years , hand sealer cmc for 4th year after expiry of warranty period of 2 years , hand sealer cmc for 5th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 1st year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 2nd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 3rd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 4th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 5th year after expiry of warranty period of 2 years , bench top minispin cmc for 1st year after expiry of warranty period of 2 years , bench top minispin cmc for 2nd year after expiry of warranty period of 2 years , bench top minispin cmc for 3rd year after expiry of warranty period of 2 years , bench top minispin cmc for 4th year after expiry of warranty period of 2 years , bench top minispin cmc for 5th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 1st year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 2nd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 3rd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 4th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 5th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 1st year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 2nd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 3rd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 4th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 1st year after expiry of warranty period of 2 years , ultracentrifuge cmc for 2nd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 3rd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 4th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 5th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 1st year after expiry of warranty period of 2 years , bench top centrifuge cmc for 2nd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 3rd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 4th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 5th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 1st year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 2nd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 3rd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 4th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 5th year after expiry of warranty period of 2 years , real time pcr cmc for 1st year after expiry of warranty period of 2 years , real time pcr cmc for 2nd year after expiry of warranty period of 2 years , real time pcr cmc for 3rd year after expiry of warranty period of 2 years , real time pcr cmc for 4th year after expiry of warranty period of 2 years , real time pcr cmc for 5th year after expiry of warranty period of 2 years , gel dock system cmc for 1st year after expiry of warranty period of 2 years , gel dock system cmc for 2nd year after expiry of warranty period of 2 years , gel dock system cmc for 3rd year after expiry of warranty period of 2 years , gel dock system cmc for 4th year after expiry of warranty period of 2 years , gel dock system cmc for 5th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 1st year after expiry of warranty period of 2 years , end point pcr proflex cmc for 2nd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 3rd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 4th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 5th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 1st year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 2nd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 3rd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 4th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 5th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 1st year after expiry of warranty period of 2 years , endotoxin detection system cmc for 2nd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 3rd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 4th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , cryoshipper cmc for 1st year after expiry of warranty period of 2 years , cryoshipper cmc for 2nd year after expiry of warranty period of 2 years , cryoshipper cmc for 3rd year after expiry of warranty period of 2 years , cryoshipper cmc for 4th year after expiry of warranty period of 2 years , cryoshipper cmc for 5th year after expiry of warranty period of 2 years...

Tata Memorial Centre - Maharashtra

31977795 supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos. along with required turnkey works. , cat ( a ) supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos along with required turnkey works. , supply, installation, testing and commissioning of linear accelerator ring gantry at actrec, kharghar, maharashtra as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at tmh, mumbai, maharashtraas per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at bbci, guwahati, assam as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at civil hospital, shillong, meghalaya as per tendered technical specifications , turnkey works at actrec , civil modification & interior works , architectural & structural audit & design consultancy: appointment of reputed, govt registered architectural, structural designer having mre than 10 years of experiencedto render interior & structural design consultancy for improvemetn and strucutral rehabilitation work as per aerbs recommendation and interior works matching the existing design, considering the following scope of work. study of available structural audit reports of the referred bunker study of the existing building drawings, structural system and history of repairs visual inspection the bunkers externally and internally tapping exercise with the use of hammer assessment of all structural elements ( slabs, beams, columns, rc walls ) conducting necessary non destructive tests on concrete of existing bunkers ultra sonic pulse velocity 15 nos. points / bunker re bound hammer min 15 nos. points / bunker conducting necessary partial destructive tests on concrete of existing bunkers core cut 1 no. points / bunker preparation separate structural audit reports certifying feasibility of proposedstructural changes at the existing bunker ( aerb drawings ) analysis & design of structural elements for accommodating proposed structural changes at the existing bunker ( aerb drawings ) considering the items mentioned in the boq. preparing ga / schematic structural drawings for proposed revisions getting client’s approval on complete set of ga / schematic drawings sharing design, analysis and ga / schematic drawings to clint appointed structural designer for vetting and incorporating suggested recomendationa and implementing the same before issuing the gfc drawings. preparing working drawings ( structural ) for proposed revisions nominal changes to accommodate in the drawing, if any, as per client’s requirement visiting site to inspect the execution work. total visits 3 nos. issuing stability certificate only after completion of work to our full satisfaction. , preparatory civil , preparation of existing rcc wall or brick wall surface, by scrapping, existing finish / paint cleaning the exposed concrete surface to remove any fungus, loosely particles, scales, by a stiff wire brush, clean by water wash the entire surface, exposed the damaged concrete surface with the help of small chisel and hammer, including collecting, stacking the debris at the site. , carefully removing or chiseling, existing plaster of thickness up to 20 mm from the damaged surface with the help of small chisel and hammer weighing not more than 5 pound, includingcollecting, stacking & carting away the debris from the site wherever required as directed by site incharge , removing existing flooring & skirting tiles, along with backing and bedding mortar, clean the surface, lifting & shifting debris to ground floor & carting away the same out of premises etc. complete. , breaking & removingexisting rcc wall by mechanical cutter without disturbing the adjacent structure, or any other concretemembers including cutting ofreinforcement bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. ( 30 mm thk ) , demolishing the existing brick wall along with plaster bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. , brick wall 230 mm thick , brick wall 115 mm thick , carefully excavating in any kind of soil, in existing building in or out sides, including necessary shoring / propping if required and including carting away the debris including re making the surface in good as same as existing as directed. including dewatering and necessary back filling complete , dismantling of existing wooden / aluminium doors and handing over to the client as directed by pm. , labor charges for shifting the furniture remove all the cupboards and shift the same as directed to facilitate the work. , dismantling existing terrace water proofing including aap membrane, cleaning the roof top free from dust and dirt with mechanical wire brush make it receive new concrete, shifing of debries from terrace to ground and carting away out of actrec campus complete as directed and instructed. , construction civil , leveling and filling of earth below foundation and plinth level with quarry dust mixed with 5% cement ( by volume ) for the depth of 150 mm. after initial fill of 75 mm thick, pour water with required compacting, watering make the sub soil in good condition, pour water to dampen the dry mix enough to cake form. similarly fill second layer of 75 mm. pour water with required compacting after each stage of layer to make the mix damp enough to become solid form , providing and laying p.c.c. m15 ( 1:2:4 ) concrete in foundation as leveling course 150 mm thick including necessary form work, batching, mixing, placing, consolidating etc. complete including wet curing for specified time period. , supplying, providing and placing in position rmc m25 reinforced cement concrete with 20mm downgraded aggregates for walls of accelerator and maze rooms of thickness ranging from 300mm to 600 mm at all levels including vibrating, curing, providing construction joints, leaving cut outs / pockets for placing of inserts / embedment, etc., complete, including cost of providing steel form work with plywood lining for all shapes ( including scaffolding, centering, etc. ) , but excluding the cost of providing reinforcement all as per specifications.include precautions to control heat of hydration and obtaining a homogeneous compact concrete. all exposed concrete surface to be of form finish complete as directed and instructed. , for foundations , for rcc shielding , for terrace shieling , providing and fixing high density ( 7.75gm / cc ) steel plate to the existing concrete surface using holdfast and hot press technique. also, the footing required to carry weight of steel plate would be included as per approved design by the consultant. , supply &fabricating and fixing reinforcement for rcc work with high yield strength ribbed cold twisted tor steel of variousdiametersand all lengths of grade fe 415 / fe 500 conforming to bis specification including cutting, bending, fabricating, welding, wastage and placing in position according to drawings and binding the reinforcement with the use of 16 gauge galvanized binding wire of double fold and providing precast cement cover blocks for main reinforcements to ensure specified cover according to relevant is code.the measurements will be in accordance with is code 1200. , supplying, drilling / cleaning hole and injecting chemical laced heavy duty stainless steel anchor fasteners widely used in strucutral reahabilitation works to support re bars and strenth enough to support additional concrete throug mechnical drilling into exisitng concrete surface. the application to be designed separately for rebars as simply supported, moment or splice connection as per indian or european standard or relevant tested and accepted rebar guidelines. rebars. of 20 mm dia 200 300mm depth. the appointed strucutral designer should submit the detailed design analysis adopted, complete as directed and instructed. , providing and doing brick work with locally available good bricks of class designation 50, in required thickness of walls, in cm 1: 4, including adding polymer admixtureat 500ml per bag of cement, racking the joints, cleaning, carting away the wastages and curing , for 230 mm thick , for 115 mm thick , providign & constructing solid cement concrete block of m 10 grade of required thickness in cm 1:6 with scafolding, labour work at all heights and levels including wastage, scafolding etc omplete as directed and instructed. , providing and doing pressure groiuting with waterproofing compound or structural reapiring compund as per manufacturers specfication as directed by the structral consultant, withinsertion of pvc nozzles with drilling holes at regulaer intervals on exisit g rcc walls, beams, roof slabs etc complete as directed and instructed. ( cosnidered for exsitng rcc walls which are developed cracks. ) , providing & applying plaster at an average thickness of 12 to 15 mm in exact line & level in the proportion of 1 : 4 cement and sand mortar by manual mixing, with addition of waterproofing chemical @ 150 ml and harbourite 12 mm fine fibrillated 100% virgin polypropylene fibers @ 150 gm per bag of cement including curing for at least 7 days, carting away a debris, cleaning ( note: waterproof plaster considered in server room only ) , filling sunken portion of roof with brick bat mixed with cm 1:6 and complete as directed and instructed , providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , miscellaneous civil , providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge. , supplying, providing and laying vitrified tiled floor, wall on cement screed using 600 x 600 mm vitrified tiles. total thickness of screed and tiles to be 30 mm. including lying 125mm high skirting all round. laid area of wall, floor and skirting measured and paid , wall tiling ( 1.8 mtr height ) , floor tiling , providing and fixing floor cover with quick access to sub floor utilities galvanized steel chequer plate for cabling modular factory finished widely for cabel laying to withstand heacy traffic movemetn of heavy matirials thelid has been designed to withstand for heavy loading, all lids are galvanized to prevent corrosion, with the larger lids having substantial underbracing to give the required strength, complete as directed and instructed. , providing and applying pest and rodent control for the required in all respect including guarantee for the 18 months , providing & layi g approved shade minimum 18mm thick granite slab in flooring, window cills etc over cement morter of 1:4 in wastage, labour. complete as directed and instructed. , provide and fixing wall paneling up to the ceiling height in radiation therapy processing room, passage and the control room, using 18 / 12mm thick high quality plywood paneling with 4mm thick veneer finished, cut to shape and size and fixed to wall in straight line including all supports, screws etc complete as per direction of engineer in charge. , p / f trap door in false ceiling with acp panel in shutter and frame fixed ovwr 50x50x2 mm thick aluminumhollow swction with epoxy sealant as per manufacturer specification suspended from ceiling with suitable ms supporting system as per site condition, including p / f 32mm thick insulation on trap door complete as directed and instructed. , painting , providing and applying oil based internal paint as per the manufacturers specification to the interior surface of masonry walls, underside of roof slabs in ups room , control room , passages, of approved colour and shade with minimum two coats of paint. item to include preparing the surface with necessary approved fillers, making good by touch up etc. to give the desired finish , all complete. rate to include cost of the tools, tackles, labour, equipment, etc. ( above wall tiling ) , providing and applying exteriorpaint widly used to mactch exisitng colour schemewaterproofing paint, scrap and clean the surface, applyprimer as base coat, over the primer coat apply two coats or more paint approved color as per manufacturers sepecification all inclusive of labour, scafolding, safety precautions etc complete as directed and instructed. , providing & applyingenamel paint to wooden or steel doors, scrapping, cleaningthe surface, washingandfillingthe crevices with approved paste / putty as filling sealant & applying the paint with one metal primer base coat, two top coats or more over the primer as per manufacturers specification, including, labour, scafolding, safety precaution etc complete as directed nd instruted. , furniture , providing and fixing 5w x 7h, 38 mm thick, double leaf doors in solid hard wood core ( phenyl formaldehyde bonded ) flush shutters both faces commercial ply including ist class c.p.t.w. lippings all around, lock plate and complete hardware, finished with both sides 1.0 mm thk. laminate as per specifications with grooves and clear / frosted glass as per design / detail complete in all aspects with necessary heacy duty hardware fixtures to mactch exisitng hardware fixtures already installed to maintain unifarmity as standerdization as per per the furniture drawing complete as directed and instructed. , repairing and alterations to existing wooden doors, by changing ss hinges, ss fittings and shutters to be 40mm thick, flush type with teak veneers on both sides open type. inclusive of fixing heavy duty automatic door a closure, two doors handles per shutter concealed night latch locking device, etc. complete. , floor mounted storage cupboards within bhabhatron room; to store: accessories. ( location: tomotherapy room passage ) size: 200 cm wide x 250 cm high x 60 cm deep ( 19mm thick commercial grade ply ) , open type cabinetwith shelves with 18 mm thick high quality plywood laminated with 0.9mm thick melamine laminates on both side of approved colour and make with 1 numbers of open type shelves 210cmx200x50cm size with 6 horizontal and 3 vertical partitions inside the therapy room with partitions for immobilization devices, electron applicator and cutouts. type and utility should match with the existing work station. provide necessary drawer 2 nos and shutter 2 nos as per the requirement from the radiation physics division. edges should be finished by machine press. all finishes and quality to be instructed by the engineering in – charge. , providing and supplying officers chair with net back revolving type.the contractor shall furnish one year warranty. economically designed and mat finish. , changing room partition ( 3x4 ) , electrival & lv works , main distribution lt panelsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 1 no 250a tp 25ka mccb + neutral link with built in adjustable o / l, s / c & e / f. mccb with rotary handle mechanism. outgoings : 1no 125a tp mccb with rotory handile machanism for ups, 1no 100a tp mccb with rotory handile machanism for chiller, 1 no. 125 a tpn mccb for hvac & 1 no 63a 25ka tpn mcb with mechanism for hvac unit. busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium .incoming and outgoing cables shall be top of bottom entry only. , ups output panel boardsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 1no 125a tp 25k mccb + neutral link with built in adjustable o / l, s / c & e / f mccb with rotary handle mechanism outgoings : 1nos. 100a 25ka tp mccb with rotary handle mechanism, & 3nos. 40a tpn mcb for db busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium . incoming and outgoing cables shall be top of bottom entry only. , electrical wiring & cabling , distribution boards supply, erection, testing and commissioning the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adaptor box above the db shell also be includeddistribution box 8 way 7segment mcb dbi / c 63 amp fp mcb 1 noo / g 63 amp dp mcb 3 nos o / g 10 / 16a sp mcb 18 nos including all interconnections and other accessories etc as reqd , supply, installation, testing andcommissioning 100a tpn mccb with water proof enclosure including earthing and all other required accessories as per site conditions. for near chiller , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , lt cables supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4r 50sq.mm copper flexible cable truebeam ups incoming & outgoing , 4r 25 sq.mm copper flexible cable for ups input & output and machine , 1c 25 sq.mm copper flexible cable for earth , 4c 16 sq.mm copper flexible cable for chiller , 4c 10 sq.mm copper flexible cable for ac , 4c 6 sq.mm copper flexible cable for db , 12c 0.75sqmm copper flexible cable with pvc conduit for chiller to control panel at console room & warning light , 1c 6sq.mm copper flexible cable for db earthing , cable terminationssupply, erection, testing and commissioning for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4r 50 sq.mm copper flexible cable , 4c 25 sq.mm copper flexible cable , 1c 25 sq.mm copper flexible cable , 4c 16 sq.mm copper flexible cable , 4c 10 sq.mm copper flexible cable , 4c 6 sq.mm copper flexible cable , submain ups and raw power circuits , supply & laying of 2r 2.5sqmm 1r 2.5pvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. , supply & laying of4 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , point wiring supply, installation, testing & commissioning of 3r 1.5sqmm pvc insulated frls copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site. , primary point , secondary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1no13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. ( ups power ) , supply, installation, testing & commissioning of 1no 6 / 16a socket and 1no switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. , installation of light fittings , supply, erection, testing and commissioning of 2 x 2led 36 watts recessed mounting fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed. , supply, erection, testing and commissioning ofled 18 watts recessed mounting down light fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed , supply, erection, testing and commissioning of single3w recessed fixed type led fitting with electronics ballast and all accessories and interconnecting with 3 core 1.5 sqmm pvc insulated frlscopper wire and fixing the same in the ceiling. , data, voice & network , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. , supply, fixing, testing and commissioning of information outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 4u communication rack , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , supply, fixing, testing and commissioning of cat 6 telephone cable . , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , earthing , supply and installation of 4 way earth bus with accessories as required , supply, installation, testing & commissioning of copper earthing with 600x600x3mm copper plate and 25x6mm copper flat bar confirmingis:3043 with the provision for watering & inspection chamber. , perforeated type gi cable tray , supplying, fabricating, erecting and connecting the following 1.6mm thickness gi perforated type cable trays with necessary supports, tees, elbows, bends, bolts and nuts and any other associated accessories to complete the job. 150mm ( wide ) x 50mm ( collar height ) , supply & fixing of 50 mm pvc pipe for cc tv, irm and speaker cable pulling , warning light supplyfixing testing & commissioning of warning light, led green, yellow, red, + power supply . , emergency stop switch supplyfixing testing & commissioning of emergency switch, 3 no. no, element with box , supply fixing & commissioning of lmo switch indicator &buzzer, ss plate with all accessories , supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 10 sq.mm copper flexible cable for ac , 1c 6sq.mm copper flexible cable for db earthing , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , supply testing & commissioning of panasonic make telephone instument with caller id , cctv the camera should be compitable with exisitng cctv system as standerdization, sample must be got approved before supply in bulk. , 16 channel dvr ful hd , hd outdoor bullet camera , hd dome camera , wd hard disk ( dvr ) 1tb , moniter ( 19.5inch ) , camera power supply ( 10amp ) , sdmi cable ( 3 meter ) , bnc conector , dc pin conector , wire 3+1 ( heavy wire ) per / meter , junction box for camera , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1 no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplid. , supply testing commissioning of token display system , firefighting works all devises should be compitable with exisitng system as standerdization, sample must be got approved before supply in bulk. supply, installation, testing & commissioning: , smoke detectors bunker 8 nos; maze 2 nos; ups 2 nos. , response indicator. , manual call bell , hooter , cu. ar. 1.5 sq.mm. cable , fire extinguisher 5kg bunker 4 nos; ups 1 no. , hvac works , supply, installation, testingandcommissioningofaircooledscroll chilling machines having actual capacity of 38.4 tr at chilled water inlet / outlet temperature of 12.0 deg. c / 7 deg. c having evaporator fouling factorof0.000018m2.k / w suitable for operation on refrigerant r 407c or eco friendly gascomprising the following complete as required. chiller capacity should not less than 38.4tr ( followingsafetyfactorwillinbuiltwithchillerunit sppr, under / over load protection, phase reverse protection, hp / lp trip signal interlocking, auto / manual test mode facility / run time equalization for multiple compressor, password access for authorized handling, pt 100 rtd sensor for chiller unit, interlocking for chilled water flow swtich ) 135kw ( 38.4tr ) , air handling units supply, installation, testingandcommissioningoffactorybuiltfloor mounted doubleskintypehorizontal / verticalairhandlingunits made of43+2mm thick panels consisting ofpreplasticizedg.i. casing of thickness 0.8 mm outside layer and 0.8 mm plane gi at inside layer with cfc free p.u. insulation of density 42 ( +5% ) kg / m3 factory injectedbetweenthem byinjectionmouldingmachine, completewith didwbackwardcurvedcentrifugalfanwithvfdstarterdriven, suitablefor50mm wgstaticpressure, coilsectionwithaluminium blue finned copper tubes ( tubes thickness not less than 0.41mm ) cooling coil of 6 row deep, filter section with 50mm thick washable synthetic type air pre filters, belt drive package with tefc drive motor suitable to operate at 415 ± 10% volts, 50hz, 3 phase ac supply, motor should be compatible with vfd, drain connections, stainless steel ( 18g ) drain pan, necessary vibration isolation pads & accessories:and piping as per the norms duly insulated with requires thick nitrile rubber. ahu starterpanelshouldhavevfdandvfdbypassoption, should have plc based control and plc bypass control for manual mode. panel should provide with heater control. note: temp and rh sensor to be included with control wiring. noadditional cost will be given for the same. 30.5 tr 12200cfm 50mm tsp ( 1 working +1 standby motor ) , supply, installation, testing and commissioningof fcu 2 tr , supply, installation, testing and commissioningof primary pump 102usgpm 15m head. , supply, installation, testing and commissioningof expansion tank ( 100 ltr ) with air separator, air vent and pressure maintaining pumping unit. , supply, installation, testing and commissioning of chilled water ms pipe with supports, hardware etc. , 80 mm dia with 32mm nitrile insulation with 26g al cladding , 25 mm dia with 19mm nitrile insulation with 26g al cladding , pvc drain pipe having pressure holding of 8kg / cm2drain piping complete with all accessories with 9mm nitrile rubber insulation with supports , 32mm dia , 25mm dia , supply, installation, testing and commissioningof valves & guages as follows with 32mm nitrile insulation for chw line: , butterfly valve , 80mm dia , 25mm dia , y strainer , 80mmdia , 25mm dia , flexible connection80mmdia , nrv valve80mmdia , 3 way valve , 80mm dia , 25mm dia , ball valve 25mm dia , airvent with ball valve , temperature gauge , pressure gauge , sitc of gi sheet metal rectangular duct with support, hangers, rods, frames, anchor fastners, etc. , 24 gauge , 22 gauge , supplying & erecting accoustic insulation lining on the ducts having 15mm thick open cell nitrile rubber armasound to reduce noise , supplying & erecting thermal insulation on the ducts having 19 mm closed cell nitrile rubber. exposed duct should cover with 26g al cladding , sitc of canvass connection for ahu machines , sitc of control cabling in between for fcu and ahuunits , sitc of fire damper , sitc of fire actuator , sitc of supply / return air grill with vcd , supply, installation and commissioning of duct strip heaters with thyristor control of necessary capacity made of ss strip ( finned / finless tubular type ) complete with rh sensor, industrial grade heating elements, protection against overheating, on / trip status, air flow switch, grounding terminals, terminals for power & control, intermediate control wiring for integration etc. for full automation working to achieve rh level of 40 60% non condensing in the treatment room. ( rating / capacity considered to be specified by the bidder ) , dismantling of existing hvac systems ahu, piping, valves , ducting / copper piping / drain piping / units / hi wall split unit all complete as per instruction as nad directed by oic es , supply and fabrication of ms structure include one coat primer and one coat enamal paint. , dismantling & re installing exisitng ac chiller plant including its roofing at terrace including disconnection of chilled water ms pipe lines, extending same till new location, with required insulation and necessarru hardware as directed and instructructed. , turnkey works at tmh mumbai , civil works : , labour charge only for removing and re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing and refixingavailbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete allonly fixing available door shutter with necessary repairing , removing existing false ceiling of any material and any size with all necessary allied works, removing out debris out of tmh premises , labour charges only for carefully removing and taking out existing wooden partitions ( partly glazed, partly panneled or fully panneled with shutters glazing etc. at all floor levels and locations including removing the existing mongery fittings fixtures locking arrangement and handling over the same to t.m.c all complete as directed , providing wood work with 1st class c.p. teak wood in frames for doors windows, ventilators, air condition frames, clear story window, false ceiling and partitions etc.wrought framed and fixed in position including applying one coat of approved wood primer to the exposed surfaces and tow coats of bitumastic paint to the surface of wood in contact with masonry / concrete etc.complete. in frames of doors, windows, ventilators and clear storey windows etc. fixed with m.s hold fast of size 40x3mmx150mm long bend to shape and embeded in cement concrete 1:2:4. , providing and fixingapproved quality machine pressed phenol formal dehy de bonded commercial / marine ply wood of approved size and fixing the same with necessary nails / screws / adhesive in partition cupboard shelves / ktichen / cabinets / flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick t.w.lipping patti at all exposed edges with nails / screws / hardwares / adhesive wastage in cutting, transportation etc. complete all.commercial ply19mm thick ply , providing and fixing 1.0mm thick laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified. 1.00 mm thick , providing and fixing cabinet made up of 19 mm. commercial ply for top, bottom, sides and shelves and 6mm commercial ply for back side.door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.0mm thick plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in drawing etc.and all exposed edges lipping with 6mm laminate finishthick t.w.lipping patti.locking arrangement withmultipurpose lock etc. all inside areas shall be .80mm thick approved colour laminate etc. with inner side 0.8mm thick laminatewith shutter , providing making and supplying computer table made out fo 19mm commercial ply for table top, mounted on the vertical side fo 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves and shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polishasshown in drawing drawer and wooden key board drawer with heavy sliding channels, withhandle for shutter, cable manager drawers all edges shall be lipped with 6mm thick t.w. lipping patti. all exposed faces should be 1.0mm thick laminate and non laminated area should be french poll shed including cost of other materials labour etc. as per drawing.computer table with all inner surface with 0.8 mm thick laminate , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick made of g i sheet having galvanizing of 100 gms / sqm ( both sides inclusive ) and electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing fixing door frame and shutter side hung to consist of partly glazed partly panneled / fully panneled / fully glazed with 5.5mm thick glass sheet and quality plain or frosted of bajri glass fixed with two way pvc lining / rubber gasket to ensure notes tightness and no rattaling and panneling with 12mm thick nova pan or ancholam finished on both side as required using extruded alumimium section forshutter frame24254545mm satin finish anodized including p / f push pull plates handles and heavy duty fittings like tower bolts, motice lock with keys hinges of 5 inch or 6 inchas per requirement hydraulic door closer / floor spring of suitable capacity etc complete.with powder coated , painting work providing & applying one / two coats of primer two coats of paint as mentioned below first quality paint to the required colour scheme and as per manufacturers instructions / specificationsto the walls, beams, columns, ceilings, partitions, doors etc. including removing existing paints , nails , screws , battens etc. and thoroughly scrapping the surface with sand papers filling up crevices and levelling with putty to obtain smooth surface ie. complete surface preparation etc. complete as directed to the entire satisfaction of engineer in charge. , with two coats of primer and two coats ofpaint , using luster paint , using synthetic enamel paint ( oil paint ) , providing and applying three coats of white wash to ceiling etc. including removing existing nails , screws , battens etc. andthoroughly scrapping the surface with sand papers, filling up the crevices and levelling with putty if necessary adding, required quantity of adhisive to obtain good finish to surface complete as directed. , civil work breaking:dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandur stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including disposing / taking away the debris outside the premises & disposing as per the guidlines of statutory authoritised. ) , granite tiles:providing & laying 8 to 10mm thickgranite tile of size 300mm x 600mmfor flooring / dado / skirting laid over a bedding of c.m. 1:335mm thick in true plain line & level curing. finishing the joints etc. complete.in flooring & in dado / skirting , electricalsworks , point wiring : point wiring for light / fan / bell with isi mark 3 x 1.5 sq.mm ( p+n+e ) . frls pvc insulated copper conductor ofmake in surface / recessed heavy class pvc casing capping / conduit with modular switch ceiling rose / batten holder / slanting holder boxes etc. with circuit labling / marking / ferruling complete. , primary point upto 4 mtrs length , primary point length 4 mtrs to 7 mtrs , primary point length7 mtrs to 10 mtrs , secondary point extending from primary point upto 4 m , dismantling: carrying out assigned jobsof dismantling the existing light, fan, bell, independent plug point wiring of all types with accessories and cable / switchgear , supply & installation of power point ( inclusive of 2no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , supply & installation of power point ( inclusive of 1 no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , telephone point : supplying and instllation of telephone point inclusive of telephone instrument, telephone socket with back box , plate, laying two pair0.5 mm gauge unarmoured telephone wire d.o.t approved, make through conduit / casing caping. , supplying and laying of 2 core audio speaker cable throughconduit / casing caping / cable tray. , sub mainsmains : providing heavy duty pvc casing caping / conduit, supplying and erecting mains with copper conductor pvc insulated frls of 1100 v ac grade wire with circuit labling / marking / ferruling complete. , 2 x 1.5 sq mm + 1.5sqmm earth wire , 2 x 2.5 sq mm + 1.5sqmm earth wire , 2 x 4 sq mm + 2.5 sqmm earth wire , light fixturessupply of led fixtures surface / suspended / recessed mounted luminaires , led light fixture duraslim 15 watt, round6500k, , led light fixture full glow 2ft x 2ft 6500k , distribution boards supply, installation, testing & commissioning dbs , spn db with metal door, 12 way, ip 43, inclusive of required rating mcb, rcbo , tpn db with metal door, 8 way, ip 43, inclusive of required rating mcb, rcbo , hvac works , hvac works ( low side ) fan coils units ( ceiling suspended type / high wall ) supply, installation, testing and commissioning of gi powder coated horizantal ceiling suspended / high wall fan coil units complete with fan, 3 speed motor, 3 row deep cooling coil, 5 mm external static, filters , copper connection, canvass connection ( if required ) , supporting arrangement, electrical wiring etc. the complete fan coil unit shall be in line with the standard specification. the capacity of fan coil units shall be as follows. proper supporting system for fcu to be provided & will be in contractors scope. 800 cfm ( 2 tr ) , hvac works ( low side ) : supply & installation of 2 wayvalve , hvac works ( low side ) : supply & installation of digital thermostat including all accessaries , mountings, wiring between thermostat & unit, terminations etc. , supply, installation testing and commissioning of the following ball valves without strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , supply, installation testing and commissioning of the following ball valves with strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , hvac works ( low side ) :supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class o applied by suiatable adhesive, as per specifications and as required complete in all respect 32mm, insulation work involve removing of old insulation on chilled water pipeline and installing new insulation. , hvac works ( low side ) : providing and fixing in position the following upvc heavy class cut to required length and installed with screw joints including the necessary fittings, supporting arrangements like clamps etc. ( bends, tees, unions, sockets etc ) duly insulated with class o 6 mm thick nitrile rubber insulation as per specifications. 25 mm dia , hvac works ( low side ) supply, installation, balancing and commissioning offabricatedat site gss sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of .63mm thickness complete as required. , hvac works ( low side ) supplying, installing of external thermal insulation on ducts of al faced / closed cell nitrile rubber insulation with anti microbial properties with duct insulation with density 40 55 kg / cum complete as per specifications. •thermal conductivity of insulation material shall not exceed 0.035 w / ( m.k ) & r value as mentioned in ecbc 2008 at mean temperature of 24 degree c as per astm c518. . class o insulation with aluminum foil. • moisture diffusion resistance factor or ‘?’ value of insulation material shall be minimum 7, 000 without any external barrier as per en 13469. • the insulation material shall have fire performance such that it passes class 1 as per bs476 part 7 for surface spread of flame and also passes fire propagation requirement as per bs476 part 6 to meet the class ‘o’ fire category. 25 mm thick. , hvac works ( low side ) supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 300 mm dia , hvac works ( low side ) supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing and commissioning of gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications , dismantling, removing of oldflexible ducting , pipelne, insulation, fcu ( 3nos ) , griil, diffuser etc loading, unloading, lifting shifting, etc and disposing the same outside tmh premises with proper housekeeping complete in all respect , networking supply, installation, testing and commissioning of lan cable room no. hbb b 002 4 nos. of network points, room no. hbb b 003 2 nos. of network points. total networks points. = 6 nos. , turnkey works for site preparation of gmc, shillong , civil shielding works , complete dismantling works inside bunker and console room, of plain cement concrete, flooring, brick work, false ceiling to any depth and width, at all levels below & above ground level of any shape, removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. rate shall include for dismantling of plain cement concrete / brick work by manually / mechanical means with necessary tools and plants, scaffolding, water and power charges, cleaning the surface, preparation of surface etc. rate shall include for stacking the serviceable materials and disposing the unserviceable materials / debris away from the site premises by mechanical means including loading, unloading, clearing the site etc. complete, as directed. ( measurement is done for floor area only ) demolishen of the walls are as per approved drawings , providing and casting in situ cement concrete m 25 ( concrete density 2.35 gms / cc ) of trap / granite / quartzite / gneiss metal for r.c.c. walls as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing complete. ( excluding reinforcement ) . with fully automatic micro processor based plc with scada enabled reversible drum type concrete mixer. with natural sand. for concrete shielding and bunker door wall as per aerb approved drawing , providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the rcc structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 ( 5 parts integral crystalline slurry : 2 parts water ) for vertical surfaces and 3 : 1 ( 3 parts integralcrystalline slurry : 1 part water ) for horizontal surfaces and applyingthe same from negative ( internal ) side with the help of synthetic fiberbrush. for bunker and console area , civil interior & furniture works , 50mm thick cement concrete flooring finished with 3mm thick vinyl flooring location: ups room , 600mmx 600mm vitrified tiles with 100mm matching tile skirting. providing and laying approved quality, colour, design and shade fully homogeneous 600 x 600 mm ( thickness to be specified by the manufacturer ) vitrified tile flooring ( marbonite or granamite, confirming to is code 15622 with water absorption less than 0.08% ) flooring in pattern as detailed in drawing or as directed by the institute and grouted with matching colour approved quality readymade grout, curing, cleaning etc to required line level etc. all complete at all leads, lifts and heights to the entire satisfaction of the institute. providing and fixing 2 3mm thick pop protection over polythene covering sheet to flooring areas till handed over and cleaning, etc all complete as per drawings & specification. ( linac room and console room ) , two coats of plastic emulsion paint over 2 coats of wall putty including primer. location: ( ups room and outside shielding wall ) , providing and laying high quality and density type vitrified wall tile of 1200 mm height in radiation therapy room and the control room, laid on 20mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) or as per the appropriate mortar rquired to hold the wall tiles together, in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge upto false ceiling level. location: ( linac and control console room ) , pest and rodent control from pci location: linac room, control console and ups room , acoustical tile for ceiling with light weight insulating material of high quality supported on grid or finished seamless with support above ceiling. to be finished with white paint or powder coated with white paint, if metallic. the false ceiling panels should be of reputed brands. location: linac room, control console and ups room , constructing cable trenches 300mm wide and 300mm deep as per the drawings , preparing and fixing openable covers of vitrified tiles fixed in the with ability to sustain a load of 200kgs to be placed on the trenches 300 mm wide, all works complete , furniture , revolving chairs height adjustable, medium back with hand rest , skylight , wall mounted storage cupboards within linac room; to store: dosimetry & qa items, linac accessories. ( location: treatment room ) . size: 2m wide x 1.2m high x 0.4m deep ( 19mm thick marine grade ply ) , 40mm thick plywood door with teak wood frame, including all accessories. size 2m x 2.2m , wooden tables for workstations. size: 3 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: console , wooden tables for workstations. size: 4 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: tps , plumbing works , supply & installation and commissioning of chiller inlet & outlet equipment flange & union , supply & installation and commissioning of pressure gauge , supply & installation and commissioning of thermometer , supply & installation and commissioning of auto air vent , supply & installation and commissioning of drain valve , supply & installation and commissioning of chiller water copper piping 15 / 8 18 gauge with insulation 19mm thick , supply & installation of chiller water pipe nylon with wire mesh hss slive flexible 40mm with insulation 13mm thick , supply & installation and commissioning of ball valves 40 mm , supply & installation and commissioning of y strainer 40 mm , supply & refilling of dm water , supply & installation and commissioning of water panel with 2 nos pressure gauge and 5 nos valve, 2 nos thermometer , hvac works , ductable a / c units along with low side works ( up to 50 running meters ) for complete installation & commissioning of ac. supply , installation , testing & commissioning of aircooled ductable split air conditioner with ceiling suspended idu and all standard fitting, gss sheet metal duct ( insulation using resin bounded glass wool with 7 micron aluminium foil ) for air distribution 22 / 24 g, idu ss drain pan as per specification complete with suitable capacity drive motor , aircooled condensor with all accessories , hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, vibration isolator pads, structural support for fixing idu / odu, safety devices including thermal protector, pressure release valve , overload relay single phase preventer etc, power wiring and control cabling ( indoor to outdoor ) , thermostat wiring, high low pressure cut out suitable for 3 phase 440v supply etc complete as required. ( warranty 3 years ) for bunker and console 5.5 tr working and 5.5tr stand by , split units with required copper piping and drainage outlet lines ( for ups room 2tr working and 2tr stand by ) with auto timer switch , 2 litre capacity dehumidifier ( for bunker 2, console 1 ) , electrical works , main lt panel supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 250a 3p mccb with rotary handle mechanism 1no with necessory interlocking arrangement out goings : 100a tpn mccb with rotary mechanism 2 nos. 63a tpn mccb with rotary mechanism 3 nos. 40a tpn mccb with rotary mechanism 1 nos. incoming and outgoing cables shall be of top or bottom entry only. , ups output panel board supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 100a 3p mccb with rotary handle mechanism 1no out goings : 100a tpn mccb with rotary mechanism 1 nos. 40a tpn mccb with rotary mechanism 2 nos. incoming and outgoing cables shall be of top or bottom entry only. , distribution boards supply, erection, testing and commisioining the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adoptor box above the db shell also be included , power & lighting dbs 6 way etpn mcb db, all mcbs shall be of c curve type only meant for lighting application i / c 63 amps fp mcb 1 no o / g 6 / 10 / 16 / 25asp mcb 18 nos including all interconnections. , ups dbs 4 way etpn mcb db, all mcbs shall be of c curve type only meant for ups power application i / c 40amps fp mcb 1 no o / g 10 / 16asp mcb 12 nos including all interconnections. , supply, installation, testing andcommissioning 100a 4p mcb with water proof enclosure including earthing and all other required accessories as per site conditions.for a / c & chiller , supply, installation, testing andcommissioning 100a mccb with ms enclosure including earthing and all other required accessories as per site conditions. for ups incoming & outgoing , l.t.cables supply, laying, testing and commisioining of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 4 sq.mm cu. ar. cable ups db incoming , 4c 10 sq.mm cu. ar. cable for pdb & hvac input cable , 4c 16 sq.mm cu. ar. cable for chillerinput cable , 4run 25 sq.mm copper flexible cable machine incomming & outgoing wiring , 4run 25 sq.mm copper flexible cable ups incomming & outgoing wiring , 1run 25 sq.mm copper flexible cable for earth cable , 4 core 50sq.mm copper ar. cable for upsin & out going power cable , cable termination supply, erection, testing and commisioining for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4c 4 sq.mm cu. ar. cable , 4c 10 sq.mm cu. ar. cable , 4c 16 sq.mm cu. ar. cable , 4run 25 sq.mm cu. flexi. cable , 1run 25 sq.mm cu. flexi. cable , 4 core 50sq.mm al. ar. cable , submains ups & raw power circuts , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( lighting & raw power circuit mains ) , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( ups circuit ) , supply & laying of 2r 4sqmm 1r 2.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( split a / c / power socket circuit ) , supply & laying of2 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , supply & laying of3 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for lmo switch wiring. , supply & laying of8 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for warning lamp wiring. , supply & laying of12 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for chiller remote panel wiring. , point wiring supply, installation, testing & commisioning of 3r1.5sqmm pvc insulated fr copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site condition , primary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1nos 6a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( raw power ) , supply, installation, testing & commissioning of 1no 6 / 13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( ups power ) , supply, installation, testing & commissioning of 1 no 16a switched socket with moulded frontplate gianodised enclosureand other associated accessories as per the site conditions. ( with indicator ) , installation of light fittings , supply, erection, testing and commisioining of 600mm x 600mm 36w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of 6 x 6 18w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of single12 v, 15w led fitting ( or ) 230v, 60wrecessed fixed type halogen fitting with copper ballast, lamps all accessories and interconnection ( dimmer light ) , supply, erection, testing and commisioining of led strip light , data, voice & network ( consile room & tps room ) , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. ( voice and data cable ) , supply, fixing, testing and commissioning of infermation outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 10 / 100 / 1000 mbps 24port t switch with 24 port patch panel , supply of 1 mtr pach card , earthing , supply & laying of 8 swg bare cu. wire , supply and installation of 12 way earth bus with all accessories as required. , supply, installation, testing & commisioning of 10 feet long 600 x 600 x 3mm copper plate or chemical earth pit for machine and ups netural and body earth , miscellaneous , supply & laying of20mm pvc hose , supply & laying of25mm pvc hose , supply, fixing of 105 x 50 mm cms tray for control room , warning lamp em off switch & lmo switch , supply & fixing of emergency stop switch and system on switch with base box , supply and fixing of magnetic door switch , supply, erection, testing and commisioining of led warning lamp for red, green & yellow . , supply, , erection, testing and commissioning of last man out control unit, last man out switch with indicator, buzzer and external wiring kit ( 1.0 sq.mm cu. wire & pipes ) , fire alarm system , supply, fixing, testing & commissioning of 2 zone conventional fire alarm panel with complete set. , supply, fixing, testing & commissioning of conventionalsmoke detectors with base , supply, erection, testing & commissioning of conventional manual call point. , supply, erection, testing & commissioning of conventional hooter / sounders , supply and laying of 2 core 1.5 sqmm copper armoured cable , carbon di oxide type fire extinguisher of 4.5 kgs. capacity, co2 gas filled in brand new seamless cylinder with powder coated finish, made out of manganese steel, with wheel type valve, discharge nozzle, bend & horn, signages etc. complete, , cc tv , supply, fixing, testing & commissioning of hd ir ccd 1 / 3” color camera. ( doom or bullet modal camera ) , supply, fixing, testing & commissioning of hd mini speed dome ir camera. with 10 to 15x zoom, auto iris lens, rs485 control ptz camera , supply, fixing, testing & commissioning of 4 chenal hd dvr , supply, fixing, testing & commissioning of ptz keyboard with joystick , supply, fixing, testing & commissioning of 24” led tv , supply, fixing, testing & commissioning of 12v dc power supply for camera , supply and laying of 3+1 rg 58 cctv cable , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplied. , turnkey works for site preparation of dr. b. borooah cancer institrute, guwhati , a ) civil works , demolishing rcc work including stacking of steel bars and disposal of unserviceable material as directed for all levels , dismantling and removing the existing door and window frame ( chowkath ) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. ( ii ) area of door / window above 3.00 m2 , demolishing cc floors of various thickness including top layer and base course and disposal of debris as directed for all levels. , providing and laying plain / reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) ( i ) using mixer machine ( a ) in substructure up to plinth level p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , ( b ) in super structure from plinth level up to 1st floor level.p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , providing form work of 12mm thick plywood board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. ( b ) floors etc. above 200mm in thickness. , supplying, fitting and fixing in position reinforcement bars conforming to relevant i.s. code for r.c.c. work / r.b. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20g annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. ( no extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate ) ( upto 1st floor level ) a ) from primary producer ( i ) tmt corrosion resistant steel ( crs ) reiforcement bar , plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete ( shuttering where necessary shall be measured and paid separately ) . ( a ) in prop 1cement: 3 sand :6 coarse aggregate by volume , 20 mm thick cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b ) on fair side ( backing coat 10 mm and finishing coat 10mm thick ) a ) in cement mortar 1:3 , providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile ) / white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. ( cement plastering to be measured and paid separately ) . ( coloured pigment should be in conformity with colour of slab and as approved and directed by the department ) . ( iii ) deluxe quality ( i ) with fix a tile , providing vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tilewhite cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) c ) delux range ii ) of size 1200mmx1600mm and above , providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile / white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) . iv ) of size300mmx900mm and above , supplying fitting and fixing of upvc partition wall 5 mm frosted glass , supplying fitting and fixing of upvc double leaf door 5 mm frosted glass , supplying fitting and fixing of upvc sliding door door 5 mm frosted glass , supplying fitting and fixing of upvcsliding window 5 mm frosted glass , providing wood work in frame ( chowkaths ) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with c.c or brick masonry wall including supplying, fitting and fixing with m.s. hold fast ( 40mmx3mmx250mm ) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with c.c and masonry as directed and specified. ( a ) with sal wood , providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent i.s code including oxidised iron butt hinges ( 100mm x 75mm x 3.5mm ) 6 nos with necessary wood screws. a ) decorative type face panel and block board core. ( iii ) 30 mm thick . , supplying, fitting, fixing and painting where necessary ( one coat primer and two coats of paint ) suspended ceiling which includes g.i. perimeter channels of size 0.55mm thick ( having one flange of 20mm and another flange of 30mm and a web of 27mm ) along with perimeter of ceiling, screw fixed to brick wall / partition with the help of nylon sleeves and screws, at 610mm c / c. then suspending g.i. intermediate channels of size 45mm ( 0.9mm thick with twoequal flanges of15mm each ) from the soffit at 1220mm c / c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with g.i.cleat and steel expansion fasteners. ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c / c. then 12.5mm thick square edge fulltone / sundance / cratone / louvertone / textured. gypboard panels of size 595mmx595mm ( conforming to is:2095 1982 ) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c / c. screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for gypboard complete at all levels as specified and directed. ( for light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary ) . ( glass wool to be measured and paid separately ) . m / f frame work with acoustic type slit gypboard ( louvertone ) tiles ( nrc value 0.72 with 50mm glass wool mat backing ) 12.5mm thick. , providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. , wall painting ( two coats ) with plastic emulsion paint on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. ( a ) .plastic emulsion paint , extra over item no 13.4.7 above for every subsequent coat of wall painting with plastic emulsion paint. ( a ) .plastic emulsion paint , water proofing of chajjas, roof slabs, terraces, sunken slabs, septic tank, oh tank, raft slab in basement, walls etc. ( b ) using polymer based cement mortar. , supplying fitting and fixing of sky view , providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections ( i ) square section ( ii ) rectangular hollow section of specification rsh / shs and ( iii ) m.s. circular hlollow section of grade 210 including purlins, bottom runners and providing m.s. cleat, m.s. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a ) using rhs / shs of grade 310 conforming to relevant i.s. code 4923 : 1997 , providing pre painted galvanized ironsheetroofing ( ppgi ) at all levels including fitting and fixing with self drilling, self tapping screws complete. ( roof trusses, purlins etc. to be measured and paid separately. ) as directed by the departement ( v ) 0.80 mm thick , earth / sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. ( b ) with hill sand obtained by truck carriage loading and unloading, and carriage to the site of work. , providing soling in foundation and under floorwith stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. ( a ) .brick on flat soling. , 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure ( ii ) in superstructure above plinth level up to 1st floor level. ( a ) . in proportion 1:3. ( 1 cement:3 sand ) , supplying, fitting and fixing chain link fencing of 10 s.w.g, g.i. wire 50mm x50mm mesh fitted to m.s angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of g.i wire 10 s.w.g at top, middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to m.s angle iron post in p.c.c base etc. with following. a ) corner and end posts with m.s angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. , supply, installation, fixing of dry chemical powder fire extinguisher confirming to is: 2171 with isi mark and co2 cartridge will be confirming to is: 4947 with isi mark, powder will be confirming to is: 4308 with isi mark ( 5 kg ) , wall panelling with ply and mica pesting , finishingold / new wall with water proofing weathercoat smooth anti fungal premium textured exterior finish ofrequired shadeafter clering and clearing the surfaces etc.including scaffolding complete as directed at alllevels ( two coats ) . , b ) external electrification works , supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor / wall mounting compartmentalize panel board of size 0.95m x 1.30mx 0.40m made of 16 swg1.66 m thick c.r. sheet and40mm x 40mm x 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of red oxide metal primer and 2 coats of enamel paint. the panel board is to be erected in 1 : 3 : 6 pcc foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 400a 4pole mccb or switch fuse unit as incomer and provision for 4nos dp or tpn out going as specified and directed by the deptt. confirming to ip 43 protection comprising of the following electrical items: 1. 40mm x 5mm 4 strip copper bus bar 1.20 m length each i20mm x 3mm 4 strip copper bus bar 0.5m each 4 sets 2. digital 3 phase voltmeter accuracy class 0.5 1 no 3. digital 3 phase ammeter accuracy class 0.5 1 no 4. pilot lamp with integral ckt led 110 230 v ( red, yellow, & blue 3 no 5. voltmeter & ammeter selector switch 2 no 6. 2 a slide fuse unit 3nos ( incoming & outgoing switch gear of reqd. rating will be measured and paid separately ) , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt.. 3 & 1 / 2 core a2xfy 240.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from main distribution panel to machine panel , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 185.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from panel to ups and ups to machine control panel , supply, installation & testing of copper plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. g.i. medium duty watering pipewith g.i. fittings such as socket, tee, elbow, nipple and 50 mmx40 mm g.i. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm c.i. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . note:for machine, chiller and ups. , extra for using salt ( 5 kand charcoal ( 96 kin g.i. / copper plate earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . , supply, fitting & fixing 20 mmx3 mm copper strips drawn on vertically or horizontally on building wall / parapet wall in surface system complete with supply of brassnuts & bolts, screws etc including riveting, soldering and making connection as approved by the deptt. ) with earth electrode copper strips and lightning arrestor etc. as specified and directed by the deptt. , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 400.00 sq.mm.3 & 1 / 2 core armoured u.g. cable , c ) internal electrification works , wiring for circuit wiring with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface / recessedpvcconduit wiring system. with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for door interlock, fault ceiling light, laser, cctv, public adress system, ceiling fan, emergency switch , 2.7.1wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts pvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit note:for 6a and 16a power points , 2.7.2wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduitincluding earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for air conditioner , wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. , sb. 8.28supplying with fitting fixing of 6 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including installation of socket outlet 6 / 16 amps 3 / 5 pin combine shuttered complete , including making necessary connection as per direction of department. , supplying with fitting fixing of 10 / 16 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including and fixing of following moulded pvc boxes for in surface system complete as per direction of department. 8 module surface moulded pvc boxes. , supplying including fitting fixing of following front plate of suitable colour as per direction of department. 8 module , supplying including and fixing of following moulded pvc boxes in surface system complete as per direction of department. 12 module horizontal surface moulded pvc boxes , supplying including fitting fixing of followingfront plate of suitable colour as per direction of department. 12 module , supplying with installation testing and commissioning of hi wall 4 star rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the deptt. ) up to 5 m between the room unit and out door unit as directed by the department. 2 ton capacity r410 , supplying with fitting and fixingvoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 5.0 kva automatic input 120 280 v out put 200 240 v , supplying with fitting and fixing of angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 ton to 2.00 ton window / split type a.c. machine , supplying with fitting and fixing of single phase modular a.c starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. , supplying including fitting fixing of followinga.c. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department [ without regulator ] . premium model1400 mm sweep. , supplying with fitting and fixing of 120 watt electronic modular step speed control 2 module type including making necessary connection as per direction of department. 120 watt electronic modular step speed control2 module type , supplying with fitting and fixing panel mounting open execution 35 / 36ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure ) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35 / 36 ka 415v 50 hz 3p mccb 400a , supplying with fitting and fixing panel mounting open execution 25 ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure of the following capacity complete with making necessary connection as approved by the deptt. as specified and directed by the deptt. 25 ka 415v 50 hz 3p mccb 125a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 100a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 63a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.c series 6 to 32a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.b series 6 to 32a , cc camera , public adress system , view box , supplying with fitting and fixing of 12watt, round led ceiling light with frame , supplying including fitting fixing of followinga.c. exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department. heavy duty 450 mm sweep 900 rpm single phase , d ) furniture works , suppying and installation of coloured tv 22 flat led wall mountingas directed by the department. , supplying fitting and fixing of furniture rack, table, store almirah, revolving chair etc. as required. , a ) computer chair ( 6 nos for control console & 6 nos. for tps room ) , b ) master table for use in computer in control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 10 x 3x2.5 ) ( 1 no for control console & 1 no. for tps room ) , c ) wall mounting manual shelf control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 6x2x16 ) , d ) shelf inside the labunkermade of best quality water proof green ply 18mm thick finishing with sunmika size ( 8 x 6x2 ) , e ) sypplying of decorative & comfortable 3 seater patient waiting chairmust be approved by the department. , cat ( b ) buy back items , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at actrec kharghar , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at tmh mumbai...

Central Railway - Maharashtra

28239493 supply of duct flexibleduct flexible, duct flexible to emd pt no. 9540362 alt a or latest dlw part no. 17270730...

Central Railway - Maharashtra

22271537 supply of supply installation and commissioning, supply installation and commissioning of sewage submersible cutter pump in diesel loco shed neral pump set consist of following items : 1) sewage submersible cutter pump 2 hp, 1.5 kw, 1ph, delivery pipe size 50 mm, cast iron impeller high chrominum steel cutter ss304 motor sousing, ss (aisi 410) shaft, model no ccpm22 make crompton 2) pvc flexible duct house size 50 mm, 10 meter 3) multicore round pvc insulated and fr pvc sheather copper conductor flexible cable 100v 1.5 sq mm 50 meter 4) modular switch board, 16 aspc mini mcb, 16 amps modular shuttered socket and 16 amps modular one way switch qty. 01 no each with labour charges for installation and commissionong...

Central Railway - Maharashtra

21982578 supply of supply installation and commissioning, supply installation and commissioning of sewage submersible cutter pump in diesel loco shed neral pump set consist of following items : 1) sewage submersible cutter pump 2 hp, 1.5 kw, 1ph, delivery pipe size 50 mm, cast iron impeller high chrominum steel cutter ss304 motor sousing, ss (aisi 410) shaft, model no ccpm22 make crompton 2) pvc flexible duct house size 50 mm, 10 meter 3) multicore round pvc insulated and fr pvc sheather copper conductor flexible cable 100v 1.5 sq mm 50 meter 4) modular switch board, 16 aspc mini mcb, 16 amps modular shuttered socket and 16 amps modular one way switch qty. 01 no each with labour charges for installation and commissionong...

Central Railway - Maharashtra

21104650 tender for supply installationitem list : (1) supply installation & commissionig of sewage submersible cutter pump indiesel loco shed kurla. pumpset consist the following items: (1) sewagesubmersible cutter pump 2 hp, 1.5kw, 1ph, delivery pipe size 50 mm, cast tron impellerhigh chromium steel cutter, ss304 motor sousing, ss (aisi 410) shaft, model no.ccpm22, make crompton (2) pvc flexible duct house size 50 mm, 10 meters (3) multicoreround pvc insulated & fr pvc sheathed copper conductor flexible cable 100v 1.5 sqmm 50 meter (4) modular switch board, 16 aspc mini mcb, 16 amps modular shutteredsocket and 16 amps modular onw way switch qty. 01 no. each, with labour chargesfor installation & commissioning.sr. section engineer (d ) crly maharashtra 1.00 set...

Indian Institute Of Science Education And Research - Maharashtra

16866801 supply and installation of laboratory equipment benches, fume hoods, exhaust system and electromechanical services in the outreach chemistry laboratory at iiser pune, lab furniture tender 1 laboratory fittings 2 laboratory sinks and drip cups 3 laboratory electrical sockets 4 data & voice sockets 5 eyewash / shower 6 spot extractor 7 fm approved safety cabinets for flammable liquids and acids 8 fume hood service fixtures 9 fume hood electrical socket 10 face velocity & vav controls 11 pp sheets for exhaust ducting 12 isothelic resin 13 pp moulded exhaust blower 14 vfd 15 fume hood face velocity monitor 16 room pressure monitor 17 actuator 18 air cooled chillers and heat pump 19 medium pressure ahu 20 supply & return diffusers & grills 21 modulating motors 22 filters 23 motors 24 galvanized sheet steel 25 ms pipes 26 m. s. fabricated support framework for in cylinders and manifolds 27 cylinder brackets with chain 28 lpg adaptor 29 nut bullnose 30 check valve 31 hose 32 cylinder isolation valve 33 manifold block 34 ss pipe 35 ss pipe fittings 36 needle valve 37 lpg regulator 38 shutoff valve 39 flash back arrestor 40 source connector compressor 41 single stage regulator 42 pressure / vacuum gauges 43 tube fittings 44 ss tubes 45 room / line isolation ball valve or outlet isolation valve low pressure 46 tube support profile 47 tube support clamps 48 tube tagging 49 ppr pipes 50 pipes fittings & valves 51 ss ball valves 52 air vent valves 53 insulation 54 gaskets 55 welding rods 56 paints 57 anchor fasteners 58 balancing valve 59 butterfly valve 60 globe valve 61 puf insulation foam 62 fibreglass material 63 thermostats and 64 humidistats 65 2 way valves 66 motorized isolation valves 67 vibration isolators 68 measuring instruments 69 cable tray 70 dx units 71 flexible ducts 72 pressure gauges 73 thermometers 74 test points 75 automatic air vent...

Mazagon Dock Limited - Maharashtra

14576848 supply, installation and commissioning of 10 ton capacity air cooled portable air conditioner plant along with flexible ducts...

Mazagon Dock Limited - Maharashtra

14560485 supply, installation and commissioning of 10 ton capacity air cooled portable air conditioner plant along with flexible ducts,...

Naval Dockyard - Maharashtra

4052768 supply of dehumidifier i) supply of 2500 cfm dehumidifier + 2500 cfm blower ii) condensing unit for 5.5 tr iii) flexible duct hose non collapsible and suitable for above machine ...