Municipal Copr Of Greater Mumbai - Maharashtra

34153516 tender for subject dismantling & shifting of medical gas pipeline system, along with its all connected accessories etc at hall e, nesco jumbo covid center, phase 2 goregaon mumbai...

Municipal Copr Of Greater Mumbai - Maharashtra

34045164 dismantling, loading, transportation, unloading & stacking of medical gas pipeline system, along with its all connected accessories at nsci jumbo covid center, worli....

Indian Army - Maharashtra

33438611 supply of medical gas for medical store echs , echs / ote / defproc / re 22 / 2022 23 , cylinder oxygen ( o2 ) gas ...

Public Health And Family Welfare - Maharashtra

33406974 bids are invited for mgps total quantity : 1 1 5x2 d type bulk cylinder wall type oxygen manifold fabricated from high pressure non arsenical, `phosphorous, deoxidized degreased seamless round 16mm od copper pipe having 15 swg thicknesses conforming to bs:6017:1981 material and manufacturer as per bs:en :1057:1996. the cylinders should be connected through extruded brass conforming bs 249 and hard soldered slip on tee at every 250mm space. the third side of the tee should have male thread for connecting each cylinder using pig tail pipes. each male connection of the tee should be connected with high pressure non return valve with spring loaded seat arrangement. the entire manifold top frame should be supported by 50mm x 50mm x 6mm thick steel angle with suitable distance piece at the back so that when the manifold top frame is installed it is 50mm away form the surface of the wall. the cylinders should be connected to the manifold through high pressure coiled half hard copper tail pipe with extruded brass end connections. one end connection of the tail pipe should be suitable for cylinder valve and the other end suitable for top frame nrv connection. the tail pipe should be half hard seamless 3/8” od and ¼” bore copper pipe. there should be indigineous 2 oxygen fully automatic changeover control panel of 2000 lpm it should fully comply and meet with the requirements of the nfpa 99/iso/htm. it should be ce marked . and all the regulators should be adiabatic certified. the manifold control system should supply any type of medical gas from both left & right hand manifold banks. it should be capable to supply a flow of over 1800 l/min. to a 400 kpa (4 bar) distribution system. either the left or right hand manifold bank should be designated duty and the control panel should be micro processor controlled and automatically changeover to supply the distribution system from the standby bank when the pressure in the duty bank falls to a pre determined level. indigineous 3 surface mounted oxygen gas outlet (front loading bs type) it should fully complies and meets with the requirements of the nfpa 99 it should be ce marked . terminal units should have gas indexing geometry to bs 5682:1998. terminal unit front fascia should be made of metal. gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. indigineous 4 oxygen bpc flow meter with humidifier it should be back pressure compensated with durable polycarbonate flow tube with cover. flow meter should have twin graduated scale which should provide precision control permanent scale graduations. flow meter should be placed in the vertical position. the flow meters should be of 0 15 lpm range for oxygen and with inlet pressure 50 60psi. indigineous specification 5 vacuum system 3 hp duplex base mounted vacuum pump each (or more) medical vacuum plant 3 phase 50 hz (package unit) fully compliant to one of the standards htm02 01/ nfpa/ din standards. the plant should comprise of base/floor mounted duplex 5 hp vacuum pumps and one no’s. of 1000 liters capacity vertical vacuum receiver tanks. the medical vacuum plant should be fully tested and a test certificate should be provided showing the results of the tests, including the free air flow rate obtained at an inlet vacuum of 450 mmhg. testing in component form is not acceptable. all vacuum pumps must be air cooled, oil lubricated type suitable for both continuous and frequent start/stop operation at nominal inlet vacuum levels of between 475 mmhg indigineous 6 sitc of vaccum pump 3 hp duplex system with receiver capacity 250 ltrs and bacteria filters as per htm standard incl electrical system indigineous 7 surface mounted vacuum outlet (front loading bs type) it should fully complies and meets with the requirements of the nfpa 99 it should be ce marked . terminal units should have gas indexing geometry to bs 5682:1998. terminal unit front fascia should be made of metal. gas specific components comprising the terminal unit second fix should be manufactured from diecast zinc alloy or similar hard wearing metal. indigineous 8 ward vacuum unit with 600 ml jars vacuum regulator and a 600ml polycarbonate collection jar with lid and plastic mounting bracket. indigineous 9 high pressure anti static tubing for vacuum (yellow) indigineous 10 copper pipes (medical grade): oxygen distribution pipeline shall be suitably designed for connection of hospital wards with jumbo cylinder manifold/ liquid dura system / psa oxygen plant with parallel connection and separate isolation valve. each hospital ward shall have individual isolation valve from header. the piped distribution system should use copper pipes manufactured from phosphorous de oxidised non arsenical copper to bs en 1412:1996 grade cw024a (cu dhp), manufactured to metric outside diameters and having mechanical properties in accordance with bs en 13348:2008 in either r250 (half hard) or r290 (hard). degreasing of pipe should be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified bs en 13348:2008. as per nhs c11 section 05 the copper tube should have bs kite mark and certificate number (mandatory). indigineous 10.1 12mm od medical grade copper pipe indigineous 10.2 15mm od medical grade copper pipe indigineous 10.3 22mm od medical grade copper pipe indigineous 10.4 28mm od medical grade copper pipe indigineous 11 isolation valves suitable for medical oxygen gas, brass body indigineous 11.1 15mm isolation valve indigineous 11.2 22mm isolation valve indigineous 11.3 28mm isolation valve indigineous 12 gas alarm panel it should fully comply and meet the requirements of the nfpa99. it should be capable of monitoring up to 6 gas services by means of pressure sensors that detect deviations from the normal operating limits.. the cover, back box and bezel should be of polyester powder. a single tamperproof fastener should be used to gain access to the hinged door. it should have each gas service displayed by colored led’s to show ‘normal’ (green), ‘low’ and ‘high’ pressure (red) conditions. medical vacuum systems should be displayed in the ‘normal’ (green) and ‘low’ vacuum (red) conditions. failure indicators should be displayed by flashing lights and normal indications should be steady. each led block indicator should be a plug in component with individual long life led’s connected in parallel in two banks to provide duplex circuits. an audible warning should sound simultaneously with any failure indication and a mute facility should be provided. indigineous 12.1 area alarm panel for 2 gas service. indigineous...

Pimpri Chinchwad Municipal Corporation - Maharashtra

32937077 pimpri chinchwad municipal corporation new bhosari jijamatathergaon and akurdi hospitals for the supply of essential liquid oxygen 02 medical gas pimpri chinchwad municipal corporation new bhosari jijamatathergaon and akurdi hospitals for the supply of essential liquid oxygen 02 medical gas , liquid oxygen gas supply liquid medical oxygen gas should be 99.9% pure. • liquid medical oxygen gas should be authentic lab tested. • liquid medical oxygen gas should be medical gas certified....

Indian Army - Maharashtra

32554828 supply of medical gas for medical store echs , echs / ote / defproc / re 22 / 2022 23 , cylinder oxygen ( o2 ) gas for...

Tata Memorial Centre - Maharashtra

32137972 supply, installation, testing and commissioning of mri 3t scan system along with required turnkey works. supply, installation, testing and commissioning of mri 3t scan system along with required turnkey works. , cat (a) supply, installation, testing and commissioning of mri 3t scan system as per tendered specifications at actrec, kharghar, navi mumbai quantity – 1 no. , supply, installation, testing and commissioning of mri 3t scan system as per tendered specifications at actrec kharghar, navi mumbai , cat (b) turnkey works required forinstallation, testing and commissioning of mri 3t scan system at actrec kharghar, navi mumbai , civil work , dismantling existing brick masonary with plaster,tile etc complete including required scaffolding etc complete , removing existing tile flooring and loose material below tiling , removing existing dado tile and loose material , removing existing plaster , removing existing doors,windows and with frame , removing of existing ducts handing over to department , removing of existing light,power pooints,wiring etc handing over to department , carting away debries outside hospital premises to permitted location as per existing norms of dumping. capacity of each truck load will be calculated against each gate bass issued by actrec. , providing and laying6 brick wall in cement mortar 1:6 , providing and laying4 brick wall in cement mortar 1:6 with patly in concrte and stell @ 4feet height , providing and laying factory made precast concrete solid blocks of 100mm/150mm/200mmthickness of grade m10 grade in superstructure above plinth level up to floor v level in cement mortar 1:6 (1 cement : 6 coarse sand) , providing 12mm tk cement plaster in cm 1:6 , providing and applying3 or more coats of plastic emulsion paint on walls as per the manufacturers directions including scaffolding etc. complete. , providing and applying vement based wall putty minimum 2mm thick , wall/floor chasing (upto 200 mm thick concerete ) , trench work as perdrawing cutting down floor finishing with tiles at bottom side and covering with ply and tile on top removable type , supply and laying concrete m20 flooring,lintels,slabs at all heights , reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the engineer in charge. (laps will not be measured). with high yield strength deformed bars (tmt bars) & ms round bars , supply and fixing 35 mm thick flush door panel with 1mm thick laminate both sidewith hinges,aldrop,door closer,door stopper etc complete , 1.5mx2.1m , 1mx2.1m , 0.8mx2.1m , supply and fixing of door frame teak wood 125mm x 100mm size 1st class teak wood with t.w. moulding of 75 x 12mm on wall & frame junction. , 1.5mx2.1m , 1mx2.1m , 0.8mx2.1m , fixing door frame : fixing available wooden frame workfor door/windows of any size by providing m.s. hold fastof size 40mm x 3mm x 150mm long bend to shape andexternal face to be painted by two coats of bitumestic paint. filling the gap with brick work /cement concrete by side finishing plastering and making good the same tc. complete. , removing & re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing & refixing availbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete all as per specified and directed by engineer in charge , supply and fixing sliding window with glass,film,aluminium section, track etc complete , removing of old false ceiling , providing and fixing tiled metal false ceiling of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all tsections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminum sheet having electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. , providing and fixing 2mm thick vinyl floor,with surface preparation ,pasting etc complete , providing and fixing acp wall paneling with aluminium faming ,pasting etc complete , supply & fixing vetrified tile 600mmx600mm flooring & skirtingover sand cement cm 1: 6 bedding. , providing fixing trap door in min 2mm thick acp with aluminum framing supported with necessarry ms struructreetc complete as directed and instructed. , providing & fixing 46mm thick fully flush double skin fire door shutter of 120 minutes fire rating confirming to is:3614(part 11),tested & certified by nabl accredated laboratory door frame & leaf shall be manufactured from 1.6mm (16 gauge) & l.2mm (18guage) minimum thick galvanised steel sheet.the internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. the infill material s~all be resin bonded honeycomb core. the edges should be interlocked with lock seam. all doors shall be finished with polyurethane aliphatic grade paint of approved colour. the door shall have passed minimum 250 hours of salt spray test. , supply and fixing gi chain link 4mmm dia mesh with ms angle frame of 50x50x6mm with flat forchiller enclosure with access ms door complete as directed and instructed with 2 coat of enamel paint over a coat of metal primer. , providing structural steel (mild steel as defined in is 800 2007 clause 2.2)for frame work of the proposed structure including fabricating, cutting, welding, rivetting, bolting, erection and oilpainting with one coat of primer and two finishing coats , providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat ofsteel primer and two coats of enamel paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses : 0.80 mm thick with zinc coating not less than 275 gm/m² . this includes ridges, valleys, long line crimps. , supply and fixing pcc (m25 grade) chiller foundation , design detailing of chiller shade , furniture , providing and placing in position following furniture , 1600mm x 600mm work station tables with 18mm thick plywood one drawer and one storage shelf with fully laminated of approved design and pattern. , 1800mmx600 mm console table 18mm play wood with fully laminated finish. , providing and placing revolving chairs with user adjustable height, medium backrest height, with hand rest manufactured by reputed furniture co which is widely used in and matching exisitng design pattern complete as directed & instructed. , chairs for patient waiting area ms three seater manufactured by repurted co and matching exisitng design patterns complete as directed & instructed. , providing and placing overhead storage with 18mm playwood fully laminate door shutters for storageas per requirement with ms bracket nicely designed & installed below storege units. , providing and placing below counter storage with 18mm playwood & fully laminate door shutters,drawers for storageas per requirement with granite top (1800x750)in mm , providing and placing cupboard with 18mm playwood with fully laminate door shutters for storage of spare parts, accessories and records, as per requirement (1800x900x600) , name boards for all rooms arcylic matching existing design patterns. , dustbins (plastic with lid) , change room locker ms powder coated with stand manufactured by reputed co matching exisitng design pattern complete as directed and instructed. , curtains with aluminnum powder coated track with suspened supports from ceiling for patient changing, complete as directed and instructed. , electrical works , wiring for 5/15 amp poweroutlet with2.5 sqmm 660/1100v pvc insulated, frls, copper conductor wiresin recessed/surface ms conduit including cost of cutting and filling chases supply andfixing of6 pin 16ampsshuttered modular switchsocket, switch plate with internal wiringin g.i. box, earthing of 3rd pin with pvc insulated, green colour 2.5 sqmm copper wire, complete with all accessories as required. (power socket). , one 16a outletonone circuit with switch socket to match existing design patterns. , 5a/15aoutletsonone circuit with two switch sockets to match existing design patterns. , wiring for radiation lamo,emergency stop,push button on off with supply of switches,and lamp , supply and laying 2.5 sqmm light wiring for radiation lamp and radiation lamp , supply and laying 2.5 sqmm light wiring for emmergency stop with emmergency stop supply , supply and laying 2.5 sqmm light wiring for push button on off with push button on off suppy , supply installation testing and commissioning of tpn mcb double door distribution boards dust and vermin protected and rated for 415v.three phase ac supply operation including incoming mccb/mcb/rcbo as per specifications and required capacity neutral bar and earth terminal complete as required and installed in flush with wall including all fixing materials required. mcbs shall conform : 8828 and rcbo/rccb shall conform to is : 12640. , 8 way tpn mcb db with 63a, tpnmcb as incomer 3 nos. 100 a copper bus bars of equal ratings and 24nos. sp mcbas outgoings . , supply, testing & commissioning of factory finished powder coated modular/ compartmentalised panel fabricated out of 14/16 swg ms sheet, dust & vermin proof with minimum ip 52(main panel) degree or protection, voltmeter, meter, indicating lamps, busbars, terminal blocks etc complete as required. as per single line diagram.tpn/spn dbs shall have ip 42 degree of protection, panel/dbs shall have space for 20% addition / deletion of feeders and with incomer 4c of 1c flexible copper conductor of appropriate sizevolt meter ( 0 500v) 1no. ammeter (0 250 amp) 1no. phase indicator lamps .all mccb microprocessor type.busbars 400amp tpn busbar of copper alloy. 400 amp/ 440v tp mccb 1no. mains .200 amp/ 440v tp mccb 1no. to ups . 200amp/ 440v tp mccb with contactor 1no. to ct. 100 amp/440v tp mccb for light and ac100 amp/440v tp mccb for chiller , 3.5 core 150 sqmm aluminum armoured cable with end termination , supply and fixing galvanised cable tray 900mm wide , supply, laying in trenches/on trays/ on racks/ on wall/ structure, testing & commissioning of the pvc insulatedflexible copper conductor power cables of the following sizes complete as required including cable marker and end termination with brass compression gland and copper lugs etc. , 1cx 95 sq mm flexible copper wire and end termination , 1cx 70 sq mm flexible copper wire and end termination , 4cx10 sqmm flexible copper wire for db , 4cx16 sqmm flexible copper wire for chiller , 4 sqmm copper insulated flexible , 2.5 sqmm copper insulated flexible wire , 1.5 sqmm copper insulated flexible wire , wiring for 6a 5/6 pin lightpoint with 1.5 mm2 660/1100v pvc insulated, frls,copper conductor cable in recessed ms conduit including cost of cutting and filling chases as required with fixing of plate, gi box, 6a modular switch shuttered socket and earthing complete with all accessories as required (first point shall be wired from 2.5 mm2660v grade pvc insulated copper wires & looping with 1.5mm2). , supply and fixing mr compatible led lights to match existing design patterns. , providing lights with fitting 600mmx600mm led type 40w to match existing design patterns. , supply and fixing data points rj45 , supply and fixing for telephone points rj45 , supply and laying network cable cat 6 supply fixingconduiting complete , supply and laying telephone cable cat 6 supply fixingconduiting complete , supply and providing network switch 16 port , supply and providing electrical point for split ac6 sqmm cable pahse neutral earthingfrom db up to ac and its switch socket , providing earthing pit copper earthing chemical typewith bore and conductor or conventional type with pit salt,coal , laying earthing conductor from earthpit to ups ,electrical room , two door interlock system with controller, in/out ss pb, em lock, door position sensor, emergency release switch, control and signal cable, etc. , sitc of 2 runs 3.50 x 150 sq mm aluminum armoured cabel from sub station to mri inclduing excavation, back filling dismantling concrete making good surface complete as directed & instructed. , sitc of 400 a tpn mccb with enclosure. , termination of 3.50 x 150 mm for aluminum armoured cable as directed & instructed. , fire fighting system , addressablesmoke detector , conventional hotter with flasher , 2 zone fire alarm panelinbuilt power supply battery charger & battery backup relay interface (common fire) , 2x1.5 sqmm copper cable armoured , response indicator , fire extinguisher 5kg , mr compatible fire extinguisher , hvac work , uninstalled existing hi wall ac including indoor, outdoor units, copper piping, cables etc from reporting room, consultant room console room etc as per instruction and as directed by oic es. , reinstalltion and commissioning of above mentioned units as per instruction and as directed by oic es , all refrigerant piping shall be of copper, complete with supports between indoor & outdoor units duly insulated with 13mm nitrile rubber insulation.rmt indicated is for set of piping between indoor and outdoor machine, individual piping will not be measured. , 1/2,1/4 or equivelant to the units , 5/8,3/8 orequivelant to the units , sitc pvc drain pipe having pressure holding of 6kg/cm2 drain piping complete with all accessories with 6mm nitrile rubber insulation 25 mm dai , sitc control cables between indoor and outdoor unit and to the main supply cables as per instructed and as directed by oic es.all exposed cable should be laid in ladder type tray , central ac , design, supply, fabrication and installation of g.s.s. ducting with volume control dampers on every branch if there is, powder coated supply/return air diffusers with required hardware’s, supports, wooden frame and painting on ducts, ms parts etc with acoustic insulation 19 mm(supply)/13 mm(return)nitrile rubberinsulation as per the smacna standard, approved drawings and instructions of engineer in charge with the following gauges. note: all exposed duct insulation should be with al cladding. , 24 gauge g.s.s. rectangular duct with necessaryinsulation and metallic foil. , dismatling of existing duct with all necessary hardeware as per instruction and as directed by oic es , grills and damper , sitc of extruded aluminium powder coated diffuser/grill with volume control damper with all necessary supports as per directed and as instructed by oic es , sitc of extruded aluminium powder coated diffuser/ grill without volume control damper with all necessary supports as per directed and as instructed by oic es , sitc of dehumidifier with capacity of 50l/day. , mgps works , copper pipes specifications of mgps system medical gases supply system distribution piping copper pipeline.the piped distribution system must use copper pipes manufactured from phosphorus deoxidized non arsenical copper. all pipelines used along with flow meter etc. should be isi mark preferably size, , 12mm & 15 mm and thickness of 0.7 & 0.9mmshould be drawn, seamless, deoxidized, nonarsenical, half hard tempered and degreased materials conforming to bs6017/1981 and manufactured as per bs 2871/the new european standard en 1057.all copper pipes are to be certified by authorized test house services for physical properties and chemical properties.copper to copper joints shall be made on site using a silver copper phosphorus brazing alloy. copper to brass or gun metal joints shall not be made on site.pipe lines should be supported at the intervals specified in htm 2022 using suitable metallic, non ferrous material. plastic supports may be used only for the drown drops to the terminal units.fitting shall be end feed type, manufactured from the same grade of copper on the pipes.fittings shall be degreased suitable for oxygen use and supplied sealed in protective bags , 12mm pipeline , 15mm pipeline for oxygen , high pressure tubing , non magnetic connector , medical gas outlets non magnetic bs standard and duly ce marked. medical gas outlets with probes. , self sealing valve outlet for oxygennon magnetic , self sealing valve outlet for vacuum non magnetic , isolation valve : 15 mm isolation valve with suitable fittings , handle without teflon tape. easy to close and operate , oxygen flow meter with humidifier bottle , it should have humidifying bottle with whole flow meter assembly, should be of light weight material. it should have backpressure compensated flow meter. it should provide accurate gas flow measure by 0 15 liter/m flow meter. flow tube should be of good quality, transparent with measuring humidifying bottle. flow meter should be fitted with matching adaptor (probe) for oxygen outlet point , ward vacuum unit , it should include vacuum pressure regular up to 760 mm hg with dial gauge . should have re usable collection bottle 1000 ml made with a wall bracelet. or unbreakable polycarbonate materials, fully auto clavable along with safety device to prevent overflow and with a wall bracetk. should be wall mounted and back flow resistance should have 600ml capacity with play contracted jar the controller should be operated by means of a 180 degree on/off switch and a bonnet adjustment , cat (b) buy back items , buy back (ie minus)amount of old mri system at actrec kharghar...

Public Health And Family Welfare - Maharashtra

31470674 bids are invited for generator 3kva , water cooler , split ac , refrigrator , three modular operation theatre and ot complex at district womens hospital solapur on turnkey basis , modular operation theatre at rural hospital akkalkot on turnkey basis , supply and installation of medical gas pipeline 100 points at district womens hospital solapur on turn key basis , hd video laproscope with all accessoriesfor mucormycosis ot , cough assist machine for icu , cardiac marker test machine for icu , blood or fluidwarmer for icu , pft machine for lunge test , stress testmachine for cardiac , video laryngoscope , standard bladesfor video laryngoscope total quantity : 154...

Public Health And Family Welfare - Maharashtra

31457071 bids are invited for binocular microscope , cell counter 3 part , n2o cylinder , co2 cylinder , boyles apparatus with circle absorber , lead apron , defibrillator with aed , pulse oximeter finger , stethoscope , nebulizer , weighing machine adult , dental unit , operationtable hydraulic major , operatingtable nonhydraulic field type , shadowless double dome led lamp ceiling type , diathermy machine , suction apparatus foot operated , hospital cots , hospital cots paediatric , dressing trolley , bed side screen , medicine trolley , bedside lockers , instrument trolley , wheel chair , stretcher patience trolley , labor table motorized , o2 cylinder trolley , saline stand , foetal doppler , 300 ma digital x ray machine , dental x ray machine , ultra sonogram machine , ecg machine , b.p.apparatus mercurial , b.p.apparatus stand model , autoclave hp vertical 2 drum , suction apparatus electrical , laparoscope operating , laryngoscope with four blades , dailysis machine , oxygen manifold supply system cylinder manifold unit 2x10 size , oxygen fully automatic changeover control panel of 1500lpm , emergency reserve oxygen manifold system 1x10 size , medical grade copper pipes size 28mm outer dia. 0.9mm thick , medical grade copper pipes size 22mm outer dia. 0.9mm thick , medical grade copper pipes size 42mm outer dia. 1.2 mm thick , medical grade copper pipes size 15mm outer dia. 0.9mm thick , medical grade copper pipes size 12mm outer dia. 1.0mm thick , medical gas area line pressure alarm digital type 3 services , medical gas area line pressure alarm digital type 2 services , gas outlet points medical gas terminal units , metal body oxygen flow meter with humidifier bottle , medical gas hose , balve valve 42mm , balve valve 28mm , balve valve 22mm , balve valve 15mm , balve valve 12mm , conversion kit , outlet ring , sali ring spannar , adestable patti pana , flow meter with humidifier bottle , oxygen probe , regulator for control pannel dual gauge , copper tail pipe , non returnable valve nrv , filter for control panel , iox 14 regulator , nrv washer set , outlet washer set , flowmeter outer tube , flowmeter inner tube , flowmeter knob , iox 14 regulator diaphragm kit , solnide valve , jenatict regulator , alaram switch , coil bolt copper tail pipes bolt , telemetry device , auto changeover pannal , 100 ma x ray machine , cardiac monitor , infussion pump , baby incubator , single surface phototherapy unit , warmer , vaccume extractor , weighing scale infant , digital audiometer , operating microscope , headlight , otoscope , tunning fork , automatic blood gas analyzer , semi auto analyzer , examination couch , autorefractrometer , opthalmoscope , slit lamp , torch , a scan biometer , keratometer , pulse oximeter , operationtable electro hydraulic , stretcherpatience trolley , dental x ray machine , ecg machine computerized , carm machine , mammography unit , cr cassette , cr system mammography compatible , ecg machine , stress test machine , pft machine , autoclave horizontal 4 drum , shadowless lamp single dome , mayos trolley , phaco machine , hd laprosocpe with accessories , shadowless lamp mobile , mogils forceps , tongue depresser , digital radiography system...

Public Health And Family Welfare - Maharashtra

31456292 bids are invited for oxygen manifold supply system 2x10 size , oxygen fully automatic changeover control panel of 1500lpm , emergency reserve oxygen manifold system 1x5 size , medical grade copper pipes size 12mm outer dia 1mm thick , medical grade copper pipes size 15mm outer dia 0.9mm thick , medical grade copper pipes size 22mm outer dia 0.9mm thick , medical grade copper pipes size 28mm outer dia 0.9mm thick , medical grade copper pipes size 42mm outer dia 1.2 mm thick , medical grade copper pipes size 54mm outer dia 1.2 mm thick , medical gas area line pressure alarm 2 gas , medical gas area line pressure alarm 3 gas , medical gas terminal units gas outlet points , metal body oxygen flow meter with humidifier bottle , medical gas hose , ball valve size 12mm , ball valve size15mm , ball valve size 22mm , ball valve size 28mm , ballvalve size 42mm , ball valve size 54mm , compressed airsystem , vacuum system , electrical control panel forcompressor and vacuum pumps , ward vacuum unit , conversion kit , outlet ring , sali ring spannar , adestablepatti pana , oxygen probe , regulator for control pannel , copper tail pipe , non returnable valve , filter for controlpanel , iox 14 regulator , nrv washer set , outlet washerset , flowmeter outer tube , flowmeter inner tube , flowmeter knob , iox 14 regulator diaphragm kit , solnidevalve , jenatict regulator , alaram switch , coil bolt coppertail pipes bolt total quantity : 44...

South Central Railway - Maharashtra

31437378 supply of (nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity.(nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity.,(nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity...

Public Health And Family Welfare - Maharashtra

31404541 bids are invited for , modular icu at central hospital ulhasnagar 3 hall no 1 , modular icu at central hospital ulhasnagar 3 hall no 2 , modular icu at pandit bhimsen joshi hospital mirabhayandra , modular icu at i.g.m hospital bhiwandi hall no 1 , modular icu at i.g.m hospital bhiwandi hall no 4 , modular icu at sub district hospital shahapur , modular icuat district civil hospital thane , modular icu at new buildingdistrict civil hospital thane hall no 1 , modular icu at newbuilding district civil hospital thane hall no 2 , duracylinder , prs system , oxygen manifold supply system2x5 size , oxygen fully automatic changeover control panelof 1500lpm , emergency reserve oxygen manifold system1x2 size , medical grade copper pipes size 12mm outer dia1mm thick , medical grade copper pipes size 15mm outerdia 0.9mm thick , medical grade copper pipes size 22mmouter dia 0.9mm thick , medical grade copper pipes size28mm outer dia 0.9mm thick , medical grade copper pipessize 42mm outer dia 1.2 mm thick , medical grade copperpipes size 54mm outer dia 1.2 mm thick , medical gas arealine pressure alarm 2 gas , medical gas area line pressurealarm 3 gas , medical gas terminal units gas outlet points , metal body oxygen flow meter with humidifier bottle , medical gas hose , ball valve size 12mm , ball valve size15mm , ball valve size 22mm , ball valve size 28mm , ballvalve size 42mm , ball valve size 54mm , compressed airsystem , vacuum system , electrical control panel forcompressor and vacuum pumps , ward vacuum unit , standard blades for video laryngoscope total quantity : 13121...

Public Works Department - Maharashtra

31325652 supply, installation, testing and commissioning of medical gas pipe line for rural hospital at ballarpur, tah.ballarpur, dist.chandrapur ( second call ) ...

Haffkine Bio Pharmaceutical Corporation Limited - Maharashtra

31184256 tender no. e 4241 / hbpcl / pc / installation testing and commissioning of integrated digital operation theater with all equipment and surgical intensive care unit ( 17 beds ) and surgical post and recovery unit ) 17 beds ) with turnkey based ( 3 modular ot pl tender no. e 4241 / hbpcl / pc / installation testing and commissioning of integrated digital operation theater with all equipment and surgical intensive care unit ( 17 beds ) and surgical post and recovery unit ) 17 beds ) with turnkey based ( 3 modular ot pl , name of the item : , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of wall panels in operation theatre as per tender technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of ceiling system in operation theatre as per tender technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of wall panels in corridor, scrub area, surgeon room and server room as per technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of ceiling system in corridor, scrub area, surgeon room and server room as pe r technical specification & this boq , flooring : supply, installation, testing & commissioning of antistatic & conductive flooring in operation theatre as per tender technical specification & this boq , flooring: supply, installation, testing & commissioning of homogeneous flooring corridor, scrub area, surgeon room and server room as per tender technical specification & this boq , supply, installation, testing & commissioning of laminar air flow ceiling as per tender technical specification & this boq , supply, installation, testing & commissioning of exhaust air shaft / cabinets as per tender technical specification & this boq , supply, installation, testing & commissioning of pressure relief damper as per tender technical specification & this boq , hospital doors: supply, installation, testing & commissioning of operation theatres door’s automatic single leaf lead lined sliding door with ss 304 door blade surface, each 2100 mm x 1500 mm as per tender technical specification & this boq , hospital doors : supply, installation, testing & commissioning of ss 304 doble leaf door size 1000 x 2100mm as per tender technical specification & this boq , supply, installation, testing & commissioning of ot touch screen control panel as per tender technical specification & this boq , supply, installation, testing & commissioning of storage cabinet system as per tender technical specification & this boq , supply, installation, testing & commissioning of ergonomic lights as per tender technical specification & this boq , supply, installation, testing & commissioning of x ray viewing system as per tender technical specification & this boq , supply, installation, testing & commissioning of magnetic writing board in each operating theatre. it should be made of ceramic having magnetic properties and should be flushed to the wall of the operating room as per tender technical specification & this boq , supply, installation, testing & commissioning of scrub sink 2 bay as per tender technical specification & this boq , supply, installation, testing & commissioning of pass through box of dimension 600mm ( width ) x 600 mm ( height ) and depth shall be minimum 600 mm as per tender technical specification & this boq , supply, installation, testing & commissioning of double arm ceiling pendant for surgeon as per tender technical specification & this boq , supply, installation, testing & commissioning of double arm ceiling pendant for anaesthesia as per tender technical specification & this boq , ot lights : supply, installation, testing & commissioning of double dome ot light with full hd camera and third arm for monitor 32” 3d 4k medical grade monitor as per tender technical specification & this boq , ot lights : supply, installation, testing & commissioning of double dome ot light with full hd camera and third arm for monitor 27” 4k medical grade monitor as per tender technical specification & this boq , supply, installation, testing & commissioning of electro hydraulic fully c arm / radiolucent ot table with accessories as per tender technical specification & this boq , supply, installation, testing & commissioning of av management and communication system as per tender technical specification & this boq , supply, installation, testing & commissioning of digital pacs viewing station 55” as per tender technical specification & this boq , supply, installation, testing & commissioning of visualization tower for advance laparoscopy surgery as per tender technical specification & this boq , supply, installation, testing & commissioning of video laryngoscope set as per tender technical specification & this boq , electrical : electrical work inside operation theatre as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of distribution board must be provided outside of each ot as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of energy efficient luminaire, 2 x 36 w cfl for corridor and auxillary rooms as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of ups :10kva on line 30 min back up as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of isolation power supply with dips system / qips system as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of ahu with air cooled package chiller / condensing units for operation theatre as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of ductwork and accessories as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of split air conditioning units 1 ton as per tender technical specification & this boq , supply, installation, testing & commissioning of medical gas piping inside all ot’s as per tender technical specification & this boq , supply, installation, testing & commissioning of hand rail crash guard system as per tender technical specification & this boq , supply, installation, testing & commissioning of corner guard protection system in ot complex as per tender technical specification & this boq , site modification any minor demolition, reconstruction, water proofing, necessary plumbing, anti microbial painting, replacement of any door or windows to provide structured design within the ot area for modular ot , wall & ceiling system in sicu, post op & recovery unit : supply, installation, testing & commissioning of wall panels in sicu, post op & recovery unit as per tender technical specification & this boq , wall & ceiling system in sicu, post op & recovery unit: supply, installation, testing & commissioning of ceiling system in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of antistatic & conductive flooring in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of ambient lights in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of nursing station ( 4000mm x 750mm ) as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1200 x 2100 mm as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1500 x 2100 mm as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1800 x 2100 mm as per tender technical specification & this boq , supply, installation, testing & commissioning of single leaf door size 900 x 2100mm as per tender technical specification & this boq , supply, installation, testing & commissioning of horizontal head panel 1200mm up to 2 gas outlets, 1500mm for up to 4 / 5outlets configuration and 1800mm for 6 / 8 outlet configurations along with electrical switches. , sitc of hospital nurse call system : sitc of vde 0834 certified / approved system switch the system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : 1 x rj45 socket, 100mb ip port ( ieee802.3100basetx ) , galvanically isolated conforming toen 60950 and vde 0834; 7 x rj45 sockets, each for a 100mb ip system port ( ieee802.3 100basetx ) for connecting all ip capable system modules; 1 x rj45 socket, 100mb ip port ( ieee802.3100basetx ) for connecting communications, staff and ward terminals as well as control panel pcsor for redundant connection. control leds for indicating the current operating state; 2 x rj45 sockets for connection of the externaldata bus; all ip system modules are supplied with power usingpower over lan technology; in case of failure ofsystem switch not more then 20 rooms or 30 beds should be affected. , sitc of hospital nurse call system : sitc of vde 0834 certified / approved patient handset without speech consisting of a plastic case in antimicrobial finish having call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, membrane keypad in antimicrobial finish with integrated leds for operation, consisting of: 1 call key, 2 lighting keys 2.80 metre connection cable with auto disconnecting rj45 connector plug. it shall be supplied with cradle for holding patient terminals. , sitc of hospital nurse call system : supply of vde 0834 certified / approved connection module for patient terminal without speech connection module for patient handset shall consist of: 1 x rj45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism, 1 membrane keypad with: 1 call button ( red with nurse symbol ) including a finder / reassurance light, 1 presence key / cancel button ( green ) including a control led, , sitc of hospital nurse call system : supply of vde 0834 certified / approved code blue call vde 0834 complied pull cord shall consist of : antimicrobial membrane keypad with 1 code blue call button ( blue ) incl. finder . reassurance light and 1 cancel button incl. control led, integrated piezo buzzer 2 x rj45 sockets for connecting to the io bus incl. an installation frame for screw free attachment with countersunk backbox , sitc of hospital nurse call system : sitc of module providing dvi output module to provide dvi output to connect with any 3rd party lcd / led monitor to display nurse call notification on external led / lcd screen. ( note: lcd / led screen to be provided by client ) , sitc of hospital nurse call system ; external led monitor for displaying nurse call status minimum 20 led wall / ceiling mounted screen having dvi input port , sitc of hospital nurse call system : supply of vde 0834 certified / approved lamp module for optical indication of calls, presences and reminders in the relevant colours conforming to vde0834 consisting of: 4 light chambers with light reflectors for homogeneous illumination, 1 light chamber fitted with 3 ultra bright red leds, 1 light chamber fitted with 3 ultra bright white leds, 1 light chamber fitted with 3 ultra bright green leds, 1 light chamber fitted with 3 ultra bright blue leds, the led life expectancy is approximately 100, 000 operating hours, , sitc of hospital nurse call system : networking & integration supply of management center nurse call server management centre server for nurse call system for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance as per vde 0834 intel xeon 3220 2, 4ghz or similar 2 gb ram, 1 x 160gb hdd 1 x dvd harddrive, 2 x gbit lan ethernet rj45 1 x serial connection rs232 and 2 x usbv2.0 1 x pci or 1 x pice socket, support for suse linux enterprise server from v10.1 the system working on any virtual plateform ( vm ware / virtual box / hyper v etc ) is striclty not allowed software event database software software pack installed on the system server for automatically logging all events in the entire communications system, such as, e.g., calls, presence markings, call acknowledgements, reminders. all the report should be able to generate on real time basis without any delay. the licesce should be for life time without any additional cost in future. , sitc of hospital nurse call system : 8 core cat6 utp cable with necessary connectors , sitc of hospital nurse call system : 25 mm pvc medium grade isi marked conduit , sitc of hospital nurse call system : power supply smps 24 v / 7 amps , sitc of intelligent addressable fully redundant fire alarm detection system : sitc of32 bit microprocessor based intelligent addressable fire alarm control panelwith 1 loopwith battery back up to 24 hours, the control panel, batteries, battery charger etc, shall be vds approved and as per en 54 standard. the panel shall consisting with minimum 240 character lcd display.panel should be able to record at least 10000 events history. each loop should be capable to have at least 250 elements / devices out of which min. 200 nos. shall be detectors. the panel shall have on board tcp / ip lan port to facilate remote operation of the panel. the system should be vds approved it is possible to commissioning the system through lan network. , sitc of intelligent addressable fully redundant fire alarm detection system : supply, installation, testing & commissioning of intelligent addressable type multisensor detector with base, with 8 bit microprocessor inbuilt, for use as heat ( fixed + rate of rise or individual ) or smoke or combined both with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each detector ) . the detector shall have ip 44 protection category & ambient temperature 20°c to + 60°c, the base shall have no electronics only dry contact terminals.the quoted item shall completely comply to the technical specification. shall be vds approvedaccording toen 54 5, 54 7, 54 17, 54 29 , sitc of intelligent addressable fully redundant fire alarm detection system : sitc addressable manual call point which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. this must have inbuilt short circuit isolator, . the ambient temperature range shall be 20°c to +50°c.the quoted item shall completely comply to the technical specification. shallbe vds approved , sitc of intelligent addressable fully redundant fire alarm detection system : sitc addressable loop powered multi tone sounder with integrated short circuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each loop powered sounder ) & having operating temperature 10°c to + 55°c shallbe vds approved , sitc of intelligent addressable fully redundant fire alarm detection system : supply, installation, testing & commissioning of vds approved analogue addressable input / output module with ip66 casingcontaining 2 inputs for monitored quering of potential free contacts amd one relay output with in built short citcuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each monitor module ) , it must be vds approved and as per en 54 standard. the ambient temperature range shall be 20°c to +60°c.the quoted item shall completely comply to the technical specification , sitc of intelligent addressable fully redundant fire alarm detection system: response indicator , sitc of intelligent addressable fully redundant fire alarm detection system : supply and laying of 2c x 1 sq.mm twised multistranded frls shielded armoured cable for fas system , sitc of intelligent addressable fully redundant fire alarm detection system : junction boxes, clamps, conduits and all necessary accessories to complete the installation , supply, installation, testing & commissioning of medical gas piping inside sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : high side :air handling unit: supplying, installation, testing and commissioning of double skin construction floor mounted draw thru type air handling units each complete with filter suction , refrigerat coil of copper tube & aluminium fins construction each for, squirrel cage induction motor, centrifugal fan with backward curved fan blades, belt drive, filters, coil size shall be selected for a maximum face velocity of 500 feet / minute and external static pressure shall be 35mm wg or as required to overcome pressure drop in the systems. motor shall be suitable for 415+ / 10% volts, 50 cycles, 3 phase / ac supply. the ahu shall be supplied with pre filter 90% down to 10 microns , puf insulation 43 mm and density 38 kg / m3. air moving and tonnage capacities shall be as detailed below, complete in all respect.maxmum noise limit 65 dba at 1 m distance. 17 tr 6800 cfm , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit: high side : air cooled direct expansion type condensing unit : the unit shall be complete with hermetically sealed scroll type compressors with constant speed designed for operation at ambient temperature of 53 deg c. condenser shall be air cooled type with copper tubes and extended aluminum fins with anticorrosive coating. condenser fan shall be of bldc motors are more efficient than conventional ac motors used by others bldc motors 40% motor efficient at lower speeds about 20 more efficient at higher speed. unit shall be design to deliver rated cooling capacity at 53 deg c ambient temperature. refrigerant shall be cfc free, either r 410a . outdoor unit shall not be more than 50meter away from the indoor unit.& vertical height 30 meter 8.5 tr dx condensing unit for dx ahu. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit: high side : ahu kit & communication kit , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : high side : remote controller with each ahu , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : supply, installation, testing and commissioning of refrigerant piping , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : drain piping 50 nb upvc, insulated with 9 mm thick elastomeric closed cell nitrile rubber insulation material, joints to be sealed with adhesive tape. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) ; 24 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) : 22 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) : 20 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply & installation of thermal insulation & acoustic insulation of duct with mechanical protection as per technical specification : thermal insulation : supply, installation, testing & commissioning of 19 mm thick nitrile rubber ( class“o” plain sheet ) closed cell insulation with alluminum foil for supply & return air duct after applying suitable adhesive for nitrile rubber. the joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.density with 40 kg / m3. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply & installation of thermal insulation & acoustic insulation of duct with mechanical protection as per technical specification : acoustic insulation : supply, installation, testing & commissioning of 10 mm thick accoustic insulation open cell class 1 insulation for supply air duct after applying suitable adhesive for nitrile rubber. the joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. density with 180 kg / m3. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supplying installation , testing & commissioning of powder coated extruded aluminium supply air square diffuser with aluminium volume control dampers as per specifications. 600x600 square diffuser , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supplying installation, testing & commissioning of powder coated extruded aluminium return air square diffuser without aluminium volume control dampers as per specifications. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply, installation, testing and commissioning of 18g gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : motorized fire damper : fire dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : motorized fire damper : actuators , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : steel structure fabrication, erection, painting for support ( inclusive supply of primer and paint ) for 11 tr dx condensing outdoor unit , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : canvas connection between duct & + ahu unit & duct , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of 5.5 tr dx type outdoor units for ahu , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of 1375 cfm ahu with dx coil unit & hepa filter. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of cabinet type inline fans of 1850 cfm for isolation room , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of aluminium ducting of following gauges 24 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of aluminium ducting of following gauges 22 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of gi ducting of following gauges : 24 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of gi ducting of following gauges : 22 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of thermal insulation of 13mm thick nitrile rubber , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of acoustic insulation of 15mm thick nitrile rubber , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of automatic fire dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of duct dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of actuator , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of supply diffuser with dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of aluminium powder coated return air grill with dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit :copper piping between ahu & dx units , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : communication cable between indoor & outdoor units. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : 32mm dia. pvc pipe for drain , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : table top ms stand for outdoor units & exhaust units. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : meghnalic gauges for isolation rooms , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of 1kw heaters for isolation rooms ahu , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 12 channel ecg machine as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of defibrillator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 7 para patient monitor as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 16 bed central nursing monitoring station as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of syringe pump as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of convective patient warming system as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of icu ventilator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of transport ventilator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of hyper hypothermia unit as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of hemodynamic ( cardiac output ) monitor as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of motorised hospital bed as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of bed cubicle with curtains netted as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of ceiling mounted iv hanger system as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of quadra color dustbin set of 4 as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of crash cart trolley stainless steel as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of medicine trolley with six drawer as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of wheelchair with handbrake as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of food table over bed table abs as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of bed side cabinet abs as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of foot step abs top table as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : site modification any minor demolition, reconstruction, water proofing, necessary plumbing, anti microbial painting, replacement of any door or windows to provide structured design within the modular sicu, post op & recovery unit...

Public Works Department - Maharashtra

31141263 supply, installation, testing and commissioning of medical gas pipe line for rural hospital at ballarpur, tah.ballarpur, dist.chandrapur...

Tata Memorial Center - Maharashtra

31130229 annual maintenance contract of medical gas system of ward block, archival block and hadron building at actrec for the year 2022 23...

Tata Memorial Centre - Maharashtra

31118035 amc medical gas system ward block annual maintenance contract of medical gas system of ward block, archival block and hadron building at actrec for the year 2022 23....

Public Health And Family Welfare - Maharashtra

31032220 bids are invited for medical grade copper piping , medical gas terminal units , lockable line valves , area line pressure alarm , oxygen flow meter with humidifier bottle , supplying, installing, testing and commissioning of vacuum unit , digital automatic changeover control panel of 2500 lpm , supplying, installing, testing and commissioning of oxygen manifold , semi automatic control panel , supplying, installing, testing and commissioning of air fully digitalautomatic changeover control panel of 2000 lpm to 2500lpm , air manifold , vacuum central system , aircompressor , air reciever tank , air dryer , supplying, installing, testing and commissio ning of filter housingcomplete , air regulator , medical gas hose , bed headpanelsboq title medical gas pipeline system total quantity : 10739...

Public Health And Family Welfare - Maharashtra

30857343 bids are invited for name of work centralized oxygen system for 32 beds at sub district hospital achalpur , name of work centralized oxygen system for 10 beds at sub district hospital daryapur , name of work centralized oxygen system for 40 beds at kuteer hospital achalpur, dist. amravati , name of work centralized oxygen system for 40 beds at super speciality hospital amravati , name of work centralized oxygen system for 30 beds at sub district hospital dharni, dist. amravat , name of work centralized oxygen system for 21 pediatric beds at district hospital amravati , name of work : providing medical gas pipeline system ( vacuum, oxygen, compressed air, ) for ward no. 5 ( peadiatric icu ) at distriact hospital, amravati , name of work : providing medical gas pipeline system ( vacuum, oxygen, compressed air, ) for ward no. 6and 8 ( peadiatric ward ) at district hospital, amravati. , name of work : providing medical gaspipeline system ( vacuum, oxygen, compressed air, ) for ward no. 10 at distriact hospital, amravati. , name of work : providing medical gas pipeline system ( oxygen and vaccum ) for pediatric icu at sub dictricthospital morshi, tq. morshi, dist. amravati , name of work : providing medical gas pipeline system ( oxygen andvacuum ) for icu at subdistrict hospital tiwsa, dist.amravati. total quantity : 11...

Public Works Department - Maharashtra

30800871 supplying, installing, testing and commissioning of medical gas pipeline for 200 bedded hospital in the premises of daffrin hospital at amravati...

Public Health And Family Welfare - Maharashtra

30733195 bids are invited for liquid medical oxygen ( lmo ) tank of 0 kl capacity with medical gas pipelline system ( mgps ) in the publichealthcare facilitiesboq title liquid medical oxygen tank 10 kl total quantity : 1...

Haffkine Bio Pharmaceutical Corporation Limited - Maharashtra

30692206 tender no. e 4241 / hbpcl / pc / installation testing and commissioning of integrated digital operation theater with all equipment and surgical intensive care unit ( 17 beds ) and surgical post and recovery unit ) 17 beds ) with turnkey based ( 3 modular ot pl tender no. e 4241 / hbpcl / pc / installation testing and commissioning of integrated digital operation theater with all equipment and surgical intensive care unit ( 17 beds ) and surgical post and recovery unit ) 17 beds ) with turnkey based ( 3 modular ot pl , name of the item with specifications : , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of wall panels in operation theatre as per tender technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of ceiling system in operation theatre as per tender technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of wall panels in corridor, scrub area, surgeon room and server room as per technical specification & this boq , wall & ceiling system in operation theatre complex: supply, installation, testing & commissioning of ceiling system in corridor, scrub area, surgeon room and server room as pe r technical specification & this boq , flooring : supply, installation, testing & commissioning of antistatic & conductive flooring in operation theatre as per tender technical specification & this boq , flooring: supply, installation, testing & commissioning of homogeneous flooring corridor, scrub area, surgeon room and server room as per tender technical specification & this boq , supply, installation, testing & commissioning of laminar air flow ceiling as per tender technical specification & this boq , supply, installation, testing & commissioning of exhaust air shaft / cabinets as per tender technical specification & this boq , supply, installation, testing & commissioning of pressure relief damper as per tender technical specification & this boq , hospital doors: supply, installation, testing & commissioning of operation theatres door’s automatic single leaf lead lined sliding door with ss 304 door blade surface, each 2100 mm x 1500 mm as per tender technical specification & this boq , hospital doors : supply, installation, testing & commissioning of ss 304 doble leaf door size 1000 x 2100mm as per tender technical specification & this boq , supply, installation, testing & commissioning of ot touch screen control panel as per tender technical specification & this boq , supply, installation, testing & commissioning of storage cabinet system as per tender technical specification & this boq , supply, installation, testing & commissioning of ergonomic lights as per tender technical specification & this boq , supply, installation, testing & commissioning of x ray viewing system as per tender technical specification & this boq , supply, installation, testing & commissioning of magnetic writing board in each operating theatre. it should be made of ceramic having magnetic properties and should be flushed to the wall of the operating room as per tender technical specification & this boq , supply, installation, testing & commissioning of scrub sink 2 bay as per tender technical specification & this boq , supply, installation, testing & commissioning of pass through box of dimension 600mm ( width ) x 600 mm ( height ) and depth shall be minimum 600 mm as per tender technical specification & this boq , supply, installation, testing & commissioning of double arm ceiling pendant for surgeon as per tender technical specification & this boq , supply, installation, testing & commissioning of double arm ceiling pendant for anaesthesia as per tender technical specification & this boq , ot lights : supply, installation, testing & commissioning of double dome ot light with full hd camera and third arm for monitor 32” 3d 4k medical grade monitor as per tender technical specification & this boq , ot lights : supply, installation, testing & commissioning of double dome ot light with full hd camera and third arm for monitor 27” 4k medical grade monitor as per tender technical specification & this boq , supply, installation, testing & commissioning of electro hydraulic fully c arm / radiolucent ot table with accessories as per tender technical specification & this boq , supply, installation, testing & commissioning of av management and communication system as per tender technical specification & this boq , supply, installation, testing & commissioning of digital pacs viewing station 55” as per tender technical specification & this boq , supply, installation, testing & commissioning of visualization tower for advance laparoscopy surgery as per tender technical specification & this boq , supply, installation, testing & commissioning of video laryngoscope set as per tender technical specification & this boq , electrical : electrical work inside operation theatre as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of distribution board must be provided outside of each ot as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of energy efficient luminaire, 2 x 36 w cfl for corridor and auxillary rooms as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of ups :10kva on line 30 min back up as per tender technical specification & this boq , electrical : supply, installation, testing & commissioning of isolation power supply with dips system / qips system as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of ahu with air cooled package chiller / condensing units for operation theatre as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of ductwork and accessories as per tender technical specification & this boq , hvac : supply, installation, testing & commissioning of split air conditioning units 1 ton as per tender technical specification & this boq , supply, installation, testing & commissioning of medical gas piping inside all ot’s as per tender technical specification & this boq , supply, installation, testing & commissioning of hand rail crash guard system as per tender technical specification & this boq , supply, installation, testing & commissioning of corner guard protection system in ot complex as per tender technical specification & this boq , site modification any minor demolition, reconstruction, water proofing, necessary plumbing, anti microbial painting, replacement of any door or windows to provide structured design within the ot area for modular ot , wall & ceiling system in sicu, post op & recovery unit : supply, installation, testing & commissioning of wall panels in sicu, post op & recovery unit as per tender technical specification & this boq , wall & ceiling system in sicu, post op & recovery unit: supply, installation, testing & commissioning of ceiling system in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of antistatic & conductive flooring in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of ambient lights in sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of nursing station ( 4000mm x 750mm ) as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1200 x 2100 mm as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1500 x 2100 mm as per tender technical specification & this boq , sliding door : supply, installation, testing & commissioning of sliding door 1800 x 2100 mm as per tender technical specification & this boq , supply, installation, testing & commissioning of single leaf door size 900 x 2100mm as per tender technical specification & this boq , supply, installation, testing & commissioning of horizontal head panel 1200mm up to 2 gas outlets, 1500mm for up to 4 / 5outlets configuration and 1800mm for 6 / 8 outlet configurations along with electrical switches. , sitc of hospital nurse call system : sitc of vde 0834 certified / approved system switch the system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : 1 x rj45 socket, 100mb ip port ( ieee802.3100basetx ) , galvanically isolated conforming toen 60950 and vde 0834; 7 x rj45 sockets, each for a 100mb ip system port ( ieee802.3 100basetx ) for connecting all ip capable system modules; 1 x rj45 socket, 100mb ip port ( ieee802.3100basetx ) for connecting communications, staff and ward terminals as well as control panel pcsor for redundant connection. control leds for indicating the current operating state; 2 x rj45 sockets for connection of the externaldata bus; all ip system modules are supplied with power usingpower over lan technology; in case of failure ofsystem switch not more then 20 rooms or 30 beds should be affected. , sitc of hospital nurse call system : sitc of vde 0834 certified / approved patient handset without speech consisting of a plastic case in antimicrobial finish having call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, membrane keypad in antimicrobial finish with integrated leds for operation, consisting of: 1 call key, 2 lighting keys 2.80 metre connection cable with auto disconnecting rj45 connector plug. it shall be supplied with cradle for holding patient terminals. , sitc of hospital nurse call system : supply of vde 0834 certified / approved connection module for patient terminal without speech connection module for patient handset shall consist of: 1 x rj45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism, 1 membrane keypad with: 1 call button ( red with nurse symbol ) including a finder / reassurance light, 1 presence key / cancel button ( green ) including a control led, , sitc of hospital nurse call system : supply of vde 0834 certified / approved code blue call vde 0834 complied pull cord shall consist of : antimicrobial membrane keypad with 1 code blue call button ( blue ) incl. finder . reassurance light and 1 cancel button incl. control led, integrated piezo buzzer 2 x rj45 sockets for connecting to the io bus incl. an installation frame for screw free attachment with countersunk backbox , sitc of hospital nurse call system : sitc of module providing dvi output module to provide dvi output to connect with any 3rd party lcd / led monitor to display nurse call notification on external led / lcd screen. ( note: lcd / led screen to be provided by client ) , sitc of hospital nurse call system ; external led monitor for displaying nurse call status minimum 20 led wall / ceiling mounted screen having dvi input port , sitc of hospital nurse call system : supply of vde 0834 certified / approved lamp module for optical indication of calls, presences and reminders in the relevant colours conforming to vde0834 consisting of: 4 light chambers with light reflectors for homogeneous illumination, 1 light chamber fitted with 3 ultra bright red leds, 1 light chamber fitted with 3 ultra bright white leds, 1 light chamber fitted with 3 ultra bright green leds, 1 light chamber fitted with 3 ultra bright blue leds, the led life expectancy is approximately 100, 000 operating hours, , sitc of hospital nurse call system : networking & integration supply of management center nurse call server management centre server for nurse call system for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance as per vde 0834 intel xeon 3220 2, 4ghz or similar 2 gb ram, 1 x 160gb hdd 1 x dvd harddrive, 2 x gbit lan ethernet rj45 1 x serial connection rs232 and 2 x usbv2.0 1 x pci or 1 x pice socket, support for suse linux enterprise server from v10.1 the system working on any virtual plateform ( vm ware / virtual box / hyper v etc ) is striclty not allowed software event database software software pack installed on the system server for automatically logging all events in the entire communications system, such as, e.g., calls, presence markings, call acknowledgements, reminders. all the report should be able to generate on real time basis without any delay. the licesce should be for life time without any additional cost in future. , sitc of hospital nurse call system : 8 core cat6 utp cable with necessary connectors , sitc of hospital nurse call system : 25 mm pvc medium grade isi marked conduit , sitc of hospital nurse call system : power supply smps 24 v / 7 amps , sitc of intelligent addressable fully redundant fire alarm detection system : sitc of32 bit microprocessor based intelligent addressable fire alarm control panelwith 1 loopwith battery back up to 24 hours, the control panel, batteries, battery charger etc, shall be vds approved and as per en 54 standard. the panel shall consisting with minimum 240 character lcd display.panel should be able to record at least 10000 events history. each loop should be capable to have at least 250 elements / devices out of which min. 200 nos. shall be detectors. the panel shall have on board tcp / ip lan port to facilate remote operation of the panel. the system should be vds approved it is possible to commissioning the system through lan network. , sitc of intelligent addressable fully redundant fire alarm detection system : supply, installation, testing & commissioning of intelligent addressable type multisensor detector with base, with 8 bit microprocessor inbuilt, for use as heat ( fixed + rate of rise or individual ) or smoke or combined both with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each detector ) . the detector shall have ip 44 protection category & ambient temperature 20°c to + 60°c, the base shall have no electronics only dry contact terminals.the quoted item shall completely comply to the technical specification. shall be vds approvedaccording toen 54 5, 54 7, 54 17, 54 29 , sitc of intelligent addressable fully redundant fire alarm detection system : sitc addressable manual call point which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. this must have inbuilt short circuit isolator, . the ambient temperature range shall be 20°c to +50°c.the quoted item shall completely comply to the technical specification. shallbe vds approved , sitc of intelligent addressable fully redundant fire alarm detection system : sitc addressable loop powered multi tone sounder with integrated short circuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each loop powered sounder ) & having operating temperature 10°c to + 55°c shallbe vds approved , sitc of intelligent addressable fully redundant fire alarm detection system : supply, installation, testing & commissioning of vds approved analogue addressable input / output module with ip66 casingcontaining 2 inputs for monitored quering of potential free contacts amd one relay output with in built short citcuit isolator ( in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short circuit isolator along with each monitor module ) , it must be vds approved and as per en 54 standard. the ambient temperature range shall be 20°c to +60°c.the quoted item shall completely comply to the technical specification , sitc of intelligent addressable fully redundant fire alarm detection system: response indicator , sitc of intelligent addressable fully redundant fire alarm detection system : supply and laying of 2c x 1 sq.mm twised multistranded frls shielded armoured cable for fas system , sitc of intelligent addressable fully redundant fire alarm detection system : junction boxes, clamps, conduits and all necessary accessories to complete the installation , supply, installation, testing & commissioning of medical gas piping inside sicu, post op & recovery unit as per tender technical specification & this boq , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : high side :air handling unit: supplying, installation, testing and commissioning of double skin construction floor mounted draw thru type air handling units each complete with filter suction , refrigerat coil of copper tube & aluminium fins construction each for, squirrel cage induction motor, centrifugal fan with backward curved fan blades, belt drive, filters, coil size shall be selected for a maximum face velocity of 500 feet / minute and external static pressure shall be 35mm wg or as required to overcome pressure drop in the systems. motor shall be suitable for 415+ / 10% volts, 50 cycles, 3 phase / ac supply. the ahu shall be supplied with pre filter 90% down to 10 microns , puf insulation 43 mm and density 38 kg / m3. air moving and tonnage capacities shall be as detailed below, complete in all respect.maxmum noise limit 65 dba at 1 m distance. 17 tr 6800 cfm , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit: high side : air cooled direct expansion type condensing unit : the unit shall be complete with hermetically sealed scroll type compressors with constant speed designed for operation at ambient temperature of 53 deg c. condenser shall be air cooled type with copper tubes and extended aluminum fins with anticorrosive coating. condenser fan shall be of bldc motors are more efficient than conventional ac motors used by others bldc motors 40% motor efficient at lower speeds about 20 more efficient at higher speed. unit shall be design to deliver rated cooling capacity at 53 deg c ambient temperature. refrigerant shall be cfc free, either r 410a . outdoor unit shall not be more than 50meter away from the indoor unit.& vertical height 30 meter 8.5 tr dx condensing unit for dx ahu. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit: high side : ahu kit & communication kit , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : high side : remote controller with each ahu , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : supply, installation, testing and commissioning of refrigerant piping , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : drain piping 50 nb upvc, insulated with 9 mm thick elastomeric closed cell nitrile rubber insulation material, joints to be sealed with adhesive tape. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) ; 24 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) : 22 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : low side : metal ducting & accessories for hvac system : supply, installation testing & commissioning of factory fabricated gi sheet metal duct as per smacna standard along with all accessories and feetings.all ductwork shall be with site fabricated. ( tantative considered qty ) : 20 g , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply & installation of thermal insulation & acoustic insulation of duct with mechanical protection as per technical specification : thermal insulation : supply, installation, testing & commissioning of 19 mm thick nitrile rubber ( class“o” plain sheet ) closed cell insulation with alluminum foil for supply & return air duct after applying suitable adhesive for nitrile rubber. the joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.density with 40 kg / m3. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply & installation of thermal insulation & acoustic insulation of duct with mechanical protection as per technical specification : acoustic insulation : supply, installation, testing & commissioning of 10 mm thick accoustic insulation open cell class 1 insulation for supply air duct after applying suitable adhesive for nitrile rubber. the joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. density with 180 kg / m3. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supplying installation , testing & commissioning of powder coated extruded aluminium supply air square diffuser with aluminium volume control dampers as per specifications. 600x600 square diffuser , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supplying installation, testing & commissioning of powder coated extruded aluminium return air square diffuser without aluminium volume control dampers as per specifications. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply, installation, testing and commissioning of 18g gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : motorized fire damper : fire dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : motorized fire damper : actuators , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : steel structure fabrication, erection, painting for support ( inclusive supply of primer and paint ) for 11 tr dx condensing outdoor unit , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : canvas connection between duct & + ahu unit & duct , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of 5.5 tr dx type outdoor units for ahu , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of 1375 cfm ahu with dx coil unit & hepa filter. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of cabinet type inline fans of 1850 cfm for isolation room , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of aluminium ducting of following gauges 24 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : isolation rooms : supply installation testing & commissioning of aluminium ducting of following gauges 22 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of gi ducting of following gauges : 24 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of gi ducting of following gauges : 22 gauge ducting , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of thermal insulation of 13mm thick nitrile rubber , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of acoustic insulation of 15mm thick nitrile rubber , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of automatic fire dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of duct dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of actuator , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of supply diffuser with dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : grills & dampers : supply installation testing & commissioning of aluminium powder coated return air grill with dampers , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit :copper piping between ahu & dx units , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : communication cable between indoor & outdoor units. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : 32mm dia. pvc pipe for drain , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : table top ms stand for outdoor units & exhaust units. , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : meghnalic gauges for isolation rooms , supply, installation, testing & commissioning of hvac for inside sicu, post op & recovery unit : supply installation testing & commissioning of 1kw heaters for isolation rooms ahu , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 12 channel ecg machine as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of defibrillator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 7 para patient monitor as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of 16 bed central nursing monitoring station as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of syringe pump as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of convective patient warming system as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of icu ventilator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of transport ventilator as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of hyper hypothermia unit as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of hemodynamic ( cardiac output ) monitor as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of motorised hospital bed as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of bed cubicle with curtains netted as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of ceiling mounted iv hanger system as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of quadra color dustbin set of 4 as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of crash cart trolley stainless steel as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of medicine trolley with six drawer as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of wheelchair with handbrake as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of food table over bed table abs as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of bed side cabinet abs as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : supply & installation of foot step abs top table as per tender technical specification & this boq , medical equipment’s and furniture for modular sicu, post op & recovery unit : site modification any minor demolition, reconstruction, water proofing, necessary plumbing, anti microbial painting, replacement of any door or windows to provide structured design within the modular sicu, post op & recovery unit...

South Central Railway - Maharashtra

30688056 supply of (nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity(nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity,(nanded surgical) (phno.:02061) nitrous oxide medical gas in bulk cylinder 17.10 cum filling capacity => limited...

All India Institute Of Medical Sciences - Maharashtra

30432414 supply installation testing commissioning of medical gas pipe line for psa plant at psa plant (3rd call) supply installation testing commissioning of medical gas pipe line for psa plant at psa plant (3rd call)...

Brihan Mumbai Mahanagarpalika - Maharashtra

30283967 annual maintenance contract of minor pumps. tender for medical gas distribution system with running operation. providing management service for daily routine work. cleaning works, up gradation of skill laboratory....