Ministry Of Defence - Maharashtra

34975271 bids are invited for refrigerant gas r23 gas with 30 kg cylinder , r404 gas with 40 kg cylinder , nitrogen gas with 7m3 cylinder total quantity : 15...

Inter-University Centre For Astronomy And Astrophysics - Maharashtra

34917323 supply, installation, testing and commissioning of hvac system at chandrasekhar auditorium at iucaa, pune supply of vrv air conditioning system comprising of the following items outdoor unit suitable for ambient temperature of 35 deg c ( r410a refrigerant ) with multiple inverter scroll compressor only, minimum 2 nos. of compressor in each system having low noise condenser fans and with multi connection piping kit, digital pressure gauge kit, pipe size reducer kit etc.compressors shall be equipped with invertor controller of insulated gate bipolar transistor ( igbt ) , make mitsubishi / daikin / general / trane / hitachi. odu 20 hp capacity with combination of dc inverter scroll compressor and constant speed hermetically sealed inverter scroll type compressor only having piping connection liquid pipe 15.9 mm, gas pipe 28.6 mm. btu not less then 1, 91, 000. air flow rate above 290 cum per minutes minimum at high speed. outdoor must have auto gas charging function. capacity control 15 100%. outdoor unit sound level not more then 65 db at a point 1 m front of unit at a height of 1.5 m. the outdoor unit shall be factory assembled, weather proof casing , constructed from heavy gauge gi sheets steel panels and coated with baked enamel finish. the outdoor unit shall be completely factory wired, tested with all necessary controls & filled with first charge of refrigerant before delivering at site. the control panel shall have incoming power mccbs / elcbs / mcbs as per vrv unit control panel specification.it should be possible to start and stop the unit from remote locations. outdoor units should be installed as per the site condition. 3 sitc of suitable i touch temperature control :the controller with multi communication cabling between ahu expansion valves and outdoor units. a multi functional compact centralized controller shall be provided with the system which shall be able to control the following function. 1 ) starting, stopping of ahu or individual unit 2 ) temperature setting of unit 3 ) switching between temperature control modes, switching of fan speeds and direction of air flow, enabling / disabling of remote controller operation. 4 ) monitoring of operation status such as operation mode and temperature setting of ahu system, maintenance information, trouble shooting information. 5 ) display ofoperation history. the controllers shall have wide screen userfriendly colour lcd display and can be wired by a non polar two wire transmission cable to a distance of 1km. 4 sitc of suitable electronic expansion valve kit with control box to control temperature of ahu having continues stability of 1.0 deg celsius with inlet / outlet joining kit. 5 imported distributive refrigerant copper piping joints ( t shape joints, y joints, branch headers etc. for suction line and liquid lines. 6 supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated.28.8 ( 11 / 8 ) or as per manufacturers specifications 7 supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated.41.1 ( 15 / 3 ) or as per manufacturers specifications 8 supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated.19.1 ( 5 / 8 ) or as per manufacturers specifications 9 supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated.22.2 ( 7 / 8 ) or as per manufacturers specifications 10 ms structural work and special supporting structure for condensing units, duly epoxy painted with 2 coat. 11 supply, fabrication & installation of thermal insulation on gi ducts complete with physically crosslinked polyolefin foamwith factory laminated reinforced aluminium foil facing with epdm fire properties as per bs 476 part 6 & 7 as per the specification. the insulation joints shall be sealed with 3 wide fire resistance tape 13 mm thick insulation 12 electrical cablingearthing, cable glands, end terminations & lugging for vrv system. cables shall be as per technical specifications and xlpe insulated type, 1.1 kv armoured with overall pvc sheath unless otherwise stated. 4c x 10 sq.mm cu. armoured conductor cable 13 control cabling : all cabling rates to include end terminations as per specifications. cables shall be as per technical specifications and xlpe insulated type unless otherwise stated.2c x 1.5 sq.mm cu. armoured conductor cable or as per manufacturers requirements. 14 supply and installation of gi perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanised ms sheets of minimum 2 mm thick with 75 mm flange to be installed horizontally or vertically. the cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc as per site condition and rate shall include cost of anchor fasteners, screws, nuts, bolts and misc. other fixing hardware painting of support structure etc as required. perforated type g.i. cable tray with gi supportsand cover size 300 mm x 75 mm. i ) structural steel such as ismc, isa, flats, rods etc to be used for support shall be included in this item. ii ) the cable tray shall be factory built. bidder shall include in his price, required numbers of tees, crosses, bends, elbows etc as required as per actual site conditions. 15 flushing, cleaning and drying of existing ahu coil ( inner side of refrigerant pipes and fins ) with suitable cleaning agent. please note that the refrigerant gas used for existing hvac systems is r 22. the inside of the ahu coil refrigerant piping must be cleaned and dried before connecting to the new vrv system. 16 refrigerant gas charging / top up with vacuuming, pressure testing, leak testing etc. 17 testing, commissioning and balancing of 20 hp x 3 nos vrv / vrf system with existing ahu as per site requirements. the entire new vrv system with the existing ahu should be operated and monitored continuously for 72 hours after satisfactory installation. 18 lifting, shifting , rigging of all outdoor units, pipes etc. up to building terrace area with required equipments 19 scaffolding for external work upto building terrace area 20 dismantling of existing hvac system ( compressor ( chillers ) , motors, pumps, cooling tower with water and refrigerant piping, cables etc. ) . 21 cat ( b ) buy back items 22 buy back ( ie minus ) buy back offer for existing 2 x 20 tr chiller ( compressor ) units, pump sets 3 nos. and 100 tr cooling tower etc. ( vendor has to quote for buy back or else his quote will be rejected ) ...

Inter-University Centre For Astronomy And Astrophysics - Maharashtra

34797112 supply, installation, testing and commissioning of hvac system , outdoor unit suitable for ambient temperature of 35 deg c ( r410a refrigerant ) with multiple inverter scroll compressor only, minimum 2 nos. of compressor in each system having low noise condenser fans and with multi connection piping kit, digital pressure gauge kit, pipe size reducer kit etc.compressors shall be equipped with invertor controller of insulated gate bipolar transistor ( igbt ) , make mitsubishi / daikin / general / trane / hitachi. odu 20 hp capacity with combination of dc inverter scroll compressor and constant speed hermetically sealed inverter scroll type compressor only having piping connection liquid pipe 15.9 mm, gas pipe 28.6 mm. btu not less then 1, 91, 000. air flow rate above 290 cum per minutes minimum at high speed. outdoor must have auto gas charging function. capacity control 15 100%. outdoor unit sound level not more then 65 db at a point 1 m front of unit at a height of 1.5 m. the outdoor unit shall be factory assembled, weather proof casing , constructed from heavy gauge gi sheets steel panels and coated with baked enamel finish. the outdoor unit shall be completely factory wired, tested with all necessary controls & filled with first charge of refrigerant before delivering at site. the control panel shall have incoming power mccbs / elcbs / mcbs as per vrv unit control panel specification.it should be possible to start and stop the unit from remote locations. outdoor units should be installed as per the site condition. , sitc of suitable i touch temperature control :the controller with multi communication cabling between ahu expansion valves and outdoor units. a multi functional compact centralized controller shall be provided with the system which shall be able to control the following function. 1 ) starting, stopping of ahu or individual unit 2 ) temperature setting of unit 3 ) switching between temperature control modes, switching of fan speeds and direction of air flow, enabling / disabling of remote controller operation. 4 ) monitoring of operation status such as operation mode and temperature setting of ahu system, maintenance information, trouble shooting information. 5 ) display ofoperation history. the controllers shall have wide screen userfriendly colour lcd display and can be wired by a non polar two wire transmission cable to a distance of 1km. , sitc of suitable electronic expansion valve kit with control box to control temperature of ahu having continues stability of 1.0 deg celsius with inlet / outlet joining kit. , imported distributive refrigerant copper piping joints ( t shape joints, y joints, branch headers etc. for suction line and liquid lines. , supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated. 28.8 ( 11 / 8 ) or as per manufacturers specifications , supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated. 41.1 ( 15 / 3 ) or as per manufacturers specifications , supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated. 19.1 ( 5 / 8 ) or as per manufacturers specifications , supply, installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnut as per the specs. the insulation shall be of 19mm thick armaflex make through out the running length of therefrigerant piping. the piping with gi tray shall be well supported at specific intervals with anchor fasteners. both refrigerant suction and liquid line shall be insulated. 22.2 ( 7 / 8 ) or as per manufacturers specifications , ms structural work and special supporting structure for condensing units, duly epoxy painted with 2 coat. , supply, fabrication & installation of thermal insulation on gi ducts complete with physically crosslinked polyolefin foamwith factory laminated reinforced aluminium foil facing with epdm fire properties as per bs 476 part 6 & 7 as per the specification. the insulation joints shall be sealed with 3 wide fire resistance tape 13 mm thick insulation , electrical cablingearthing, cable glands, end terminations & lugging for vrv system. cables shall be as per technical specifications and xlpe insulated type, 1.1 kv armoured with overall pvc sheath unless otherwise stated. 4c x 10 sq.mm cu. armoured conductor cable , control cabling : all cabling rates to include end terminations as per specifications. cables shall be as per technical specifications and xlpe insulated type unless otherwise stated.2c x 1.5 sq.mm cu. armoured conductor cable or as per manufacturers requirements. , supply and installation of gi perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanised ms sheets of minimum 2 mm thick with 75 mm flange to be installed horizontally or vertically. the cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc as per site condition and rate shall include cost of anchor fasteners, screws, nuts, bolts and misc. other fixing hardware painting of support structure etc as required. perforated type g.i. cable tray with gi supportsand cover size 300 mm x 75 mm. i ) structural steel such as ismc, isa, flats, rods etc to be used for support shall be included in this item. ii ) the cable tray shall be factory built. bidder shall include in his price, required numbers of tees, crosses, bends, elbows etc as required as per actual site conditions. , flushing, cleaning and drying of existing ahu coil ( inner side of refrigerant pipes and fins ) with suitable cleaning agent. please note that the refrigerant gas used for existing hvac systems is r 22. the inside of the ahu coil refrigerant piping must be cleaned and dried before connecting to the new vrv system. , refrigerant gas charging / top up with vacuuming, pressure testing, leak testing etc. , testing, commissioning and balancing of 20 hp x 3 nos vrv / vrf system with existing ahu as per site requirements. the entire new vrv system with the existing ahu should be operated and monitored continuously for 72 hours after satisfactory installation. , lifting, shifting , rigging of all outdoor units, pipes etc. up to building terrace area with required equipments , scaffolding for external work upto building terrace area , dismantling of existing hvac system ( compressor ( chillers ) , motors, pumps, cooling tower with water and refrigerant piping, cables etc. ) . , cat ( b ) buy back items , buy back ( ie minus ) buy back offer for existing 2 x 20 tr chiller ( compressor ) units, pump sets 3 nos. and 100 tr cooling tower etc. ( vendor has to quote for buy back or else his quote will be rejected ) => limited...

Indian Army - Maharashtra

34779208 bids are invited for supply of stores freon gas r 22 in returnable cylinder having capacity of 61 kgs , refrigerant gas r 407c in returnable cylinder having capacity of 45 kgs , refrigerant gas r 134a in returnable cylinder having capacity of 62 kgs , compressor oil in sealed container total quantity : 6397...

Indian Army - Maharashtra

34644485 bids are invited for repair of staff car maruti dezire m and l for jack up the vehicle and replace the defective spare parts with new such as engine oil , m and l for servicing and repairing, cleaning ac filter valves and top up of refrigerant gas total quantity : 2...

Central Railway - Maharashtra

34640647 supply of refrigerant gasrefrigerant gas, refrigerant gas r407 / c in 50kgs cylinders. returnble cylinder....

Ministry Of Coal - Maharashtra

34352054 bids are invited for ac sparesmse compressor, part no 955ac02151 , receiver drier,part no 955ac11953 , binary switch,part no rd54640op , motor 24v,part no rd5504924 , valve,part no rd58076op , evaporator core assy,part no rd213700 , thermostat,part no rd442724 , 3 speed switch,part no rd53646o , expansion valve,part no rd56868o p , compressor oil,part no rd57103o p , hose 50 ft,part nord5500860 0p , hose 50 ft,part no rd5501060 0p ,hose 50 ft,part no rd55006600p , 10 female 90degree,part no rd57231o p , 10 male straight,partno rd56951o p , fitting,part no rd57225o p , 8 female90 degree,part no rd56840o p , 6 female 90degree,part no rd56945o p , 6 male straight,part nord57805o p , refrigerant gas,part no r134a total quantity : 163...

Military Engineer Services - Maharashtra

34304069 repair and maintenance of ac plant ducting, cooling appliances, split type ac, windowac, water cooler, refrigerator, deepfreezer, desert cooler, voltage stabilizers and misc items at 2wing air force station pune 1 m&l for servicing, cleaning of complete unit ( indoor and out door ) of air cooled split type ac ofany capacity by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection , cleaning the air filters, combing of fins by using fins comb includingreplacing defective filters, burnt wiring, tightening of electric wiring connections, etc, complete all as specified and directed. 2 m&l for replacement of existing old u / s insulation of refrigerant pipes of spit air conditionerup to 3 tr cap complete all as specified and directed. 3 m&l for replacement of micro processor printed circuit board complete suitable for split type acs as per exiting make & model up to 3 tr cap complete all as specified and directed. 4 m&l for replacement of unsv pcb of indoor / outdoor unit of inverter type ac as per existing make & model complete all as specified and directed. 5 m&l taking out defective micro processor printed circuit board of split type ac of existingmake / model up to 3 tr capacityfor repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed. 6 m&l for replacement of unserviceable starting capacitor suitable of window type / split type acsup to 3 tr capacity as per existing cap complete all as specified and directed. 7 m&l for replacement of unserviceable running capacitor 30 / 36 / 40 / 45 / 55 mfdsuitable for split / window type acs1 to 3 tr cap of existing make & model complete all as specified and directed. 8 m&l for replacement of capacitor 4 / 6 mfd suitable forfan motor of ( split / window / water cooler / desert cooler fanmotor ) complete all as specified and directed. 9 m&l for replacement of unserviceable swinging motor of indoor unit of split type ac up to 3tr capacity suitable for existing make / model complete all as specified and directed. 10 m& l for replacement of condenser fan / blower motor with bush and washers as per existing make and model for split type ac up to 3 tr capacity complete all as specified and directed. 11 m&l for replacement of existing unsv compressor unit with new compressor unitas per existing make & modelincludingtakingout the old u / s burnt out compressor of split type air conditioner, unsvreplacement ofbushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor, cutting, brazing of copper piping, charging of suitable refrigerant gas as required qty to obtained desired cooling, carry out leak test etc., all as required at site completeforfollowing capacity: existing make: emerson / carrier / tecumsha / lg / voltas 12 capacity 1.5 tr 13 capacity 2.0 tr 14 capacity 3.0 tr 15 m&l for replacement of unserviceable fan blade of condenser unit of split type ac up to 3 tr as per existing make and model complete all as specified and directed. 16 m&l forleakdetection by nitrogen pressure test in refrigerant system of ac, cutting brazing and making leak proofthe gas system, cleaning, vacuum thegas system and charging suitable gas as required quantity to achieve desire cooling complete all as specified and directed. 17 split type ac1.5 tr capacity 18 split type ac2.0 tr capacity 19 split type ac 3.0 tr capacity 20 m&l for replacement of unsv contactor kit of split type ac as per existing make & modelup to 3 tr complete all as specified and directed. 21 m&l for replacement of unsv copper tubing5 / 8 dia complete all as specified and directed. 22 m&l for replacement of unsv copper tubing 3 / 8 dia complete all as specified and directed. 23 m&l for replacement of unsv power cable cord pvc flexible copper wire2.5 sqmm 3 core complete all as specified and directed. 24 labour only forrectification of water leakage problem by cleaning indoor unit & drain pipe of split type ac up to 3 ton cap complete all as specified and directed 25 m&l for replacement of unsvvalve of split type ac of existing make up to 3 tr cap complete all as specified and directed. 26 m& l for replacement of unserviceable hermetically sealed / rotary compressor with new compressor suitable for window type ac of following capacity, including replacement of unserviceable bushes, sleeves, washers nut and bolt , foundation legs including relay terminal cover and clips and including cutting, brazing, leak detection, charging of suitable refrigerant gas as required to obtained desired cooling, carry out leak test etc., all as required at site complete commissioning, testing for the following capacity existing make emerson / carrier / tecumsha / lg / voltas 27 compressor suitable for 1.5 tr capacity 28 compressor suitable for 2.0 tr capacity 29 m&l for servicing, cleaningof window type acs of capacity 1.0 / 1.5 / 2.0 tr by blower, cleaning condenser coil with water, combing finsincluding replacement of defective filter, selector knobs, burnt wiring , tighting, checking of electrical connections etc. complete all as specified and directed. 30 m&l for replacement ofunserviceableelectric blower motor suitable for 1 / 1.5 / 2tr capacitywindow type ac double speed, single phase 230 volt 50 hz, complete all as specified and directed.make gulmarg / aue or as per existing make / type. 31 m&l for replacement of unserviceable thermostat switch suitable for water coolers, window typeacs / split acs, refrigerators and deep freezersany capacity, make & model all as directed. 32 m&l for replacement of starting relay suitable for water coolers, window typeacs / split acs, refrigerators and deep freezersany capacity, make & model complete all as specified and directed. 33 m&l for replacement of existing unsvfan motor of desert coolers up to 6000cfm as per existing model & speed including taking outthe old / unserviceable motor complete all as specified and directed. 34 m&l for replacement unservicable water pump of desert cooler with submersible type water pump0.6 kw, 1.25 m head pump complete all as specified and directed. 35 m&l for replacement of khas pad ( set of three ) with best quality new pad, fordesert coolers of 4000 / 5000 cfm capacity complete all as specified and directed. 36 m&l for replacement of fan speed control switch of desert cooler up to 6000 cfm pvc bodyunit as per existing make & model complete all as specified and directed. 37 m&l for replacement of louvers control knob switch of desert cooler up to 6000 cfm pvc bodyunit as per existing make & model complete all as specified and directed. 38 m&l for replacement of unsv fan blade of desert cooler up to 6000cfm as per existing type make & model complete all as specified and directed. 39 m&l for replacement of honeycomb pads of desert cooler up to 6000cfm as per existing complete all as specified and directed. 40 m&l for replacement of desert cooler body 66x660x900 mm with front grill and three side louver fabricatedout of 22 gauge mild steelplan blacksheet and bottomwater tank ( sump ) of size 660x660x200 mm deep fabricated out of 20 gauge milled steel plan blacksheet including takingout and reinstallationcomplete with standard fittingsuch as pvc pipe forwater electric motorand fan motor clamp for motor, switch fan speed regulatorincluding fixingand connctingexistingcooler fan electric pump with core pvcinsulated & pvc sheathed cable ( min 3 mtr in length external surface shall bespray painted withapproved paint over a coat of red oxide primerand internall surfaceofbody cooler pump and motor shall bepaint with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed. 41 m&l in replacement of 01nos front grill and 3 side louverssuitable fordesert cooler duly spray painted with approved paint overa coat of redoxide primer and internal surfac of body coolerpump and motor shall bepainted with two coat of bituminous paintover a coat of red oxideprimercomplete all as specified and directed. 42 m&l for servicing of water cooler of installed capacity40 / 40to 150 / 150 ltrs, cleaning the tank, condenser coil, oiling the fan motor, checkingall parts, repair to electrical burnt / loose connection, replacement of rubber gasket, washer minor u / s parts etc. all as specified and directed. 43 supply and fix hermetically sealed unit new compressor by dismantling burnt out u / s compressor suitable for water coolers of following capacitiesincluding provn ofbushes, sleeves, washers nut and bolt for 4 / 3 compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity: make of existing water cooler : emerson / carrier / tecumsha / lg / voltas 44 cooling capacity 40 ltrs / hr 45 cooling capacity 60 ltrs / hr 46 cooling capacity 150 ltrs / hr 47 m&l for replacment of freezer of refrigerator as per existing make model including cutting, brazing complete all as specified and directed of cap 192 to 385 ltr 48 s&f push cock cp brass of 15 mm dia for water cooler and taking out the unserviceable push cock and complete all as specified and directed. 49 m&l for replacement of unsv float valve for water cooler ( 40 / 60 / 120 / 150 ltrs ) capacity any as per existing size and type complete all as specified and directed. 50 servicing of air curtains, single phase, 240v by checking all electrical connection, blower, motor oiling greasing and replacement of u / s wire, lugs, bushes, rubber pads, bearing etc. complete all as specified and directed. 51 m&l for replacment ofhermetically sealed / rotarey compressor by dismantling burnt out u / s compressor suitable for refrigeratorsincluding provn ofbushes, sleeves, washers nut and bolt for 4 / 3 compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity. ( existing make : emerson / carrier / tecumsha / lg / voltas ) 52 165 200ltrs capacity 53 285 300 ltrs capacity 54 m&l forleakdetection in refrigerant system ofrefrigerator ( 165 to 300 ltrs cap ) including cutting brazing and making leak proofthe gas system, cleaning, vacuum thegas system and charging suitable gas as required quantity complete all as specified and directed. 55 taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re use or deposit in store complete all as specified and directed. 56 fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through stone masonry wallwith connected accessories such as bracket, copper tubing, cable from indoor to out door unit and rain water pipe etccomplete all as specified and directed. 57 m&l for replacement of old unsv outdoor unit of split typewith ac 3 star rating, 1.5 tr cap having copper tubing, high eer rating compressor ( for gas r 407 / 410 / 32 ) , blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and chargingsuitable refrigerant gasto achieve desired cooling effect and testing complete all as specified and directed.existing make blue star / voltas / hitchin / daiken 58 servicing of ceiling suspended dx type ahu of vrf system by checking all parts, repair to electrical connection, cleaning of air filter, cooling coil, fan / blower and replacing minor u / s parts like bushes, nut bolts including taking down air diffuser grill from fall ceiling, cleaning and refixing of the same complete all as specified and directed. 59 m&l for replacement of unsv indoor unit of split type ac 1.5 tr complete having 3 star rating suitable for ( r 407 / 410 / 32 ) gas complete all as specified and directed. existing make voltas / blue star / hitachi / daiken 60 m&l for replacement of unsv mcb sp c series 20 a to 32 a m breaking cap 6ka complete all as specified and directed. existing make l&t / legrand / hager / siemens 61 m&l for replacement of metal plug 20a, 2pin+sc complete all as specified and directed.existing make : l&t / legrand / hager / siemens 62 m&l for replacement of metal socket 20a, 2 pin+sccomplete all as specified and directed.existing make :l&t / legrand / hager / siemens 63 m&l for replacement of unsv sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole c series mcb 20 amps, 240 volts complete all as specified and directed. existing make: l&t / legrand / hager / havels 64 m / l for sub main wiring with two runs of single core 4.0 sq mm frls pvc insulated unsheathed multi stranded copper conductor1100 v grade with colour code and one run of 4.0 sq mm single core frls pvc insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & capping complete all as specified and directed. ( note :two runs of 4.0 sqmm copper cable, one run ofearth wire of 4.0 sqmm copper cable shall be measured & paid as one length ) . 65 servicing of air shower for 2 persons by checking all electrical connection, replacing u / s wire, lugs, washers, sensors, push button, cleaning filters, blower motor servicing, oiling, replacement of bearing of blower assembly, bush etc complete all as specified and directed. 66 m&l for replacement of unsv doormat magnetic switch of air shower complete all as specified and directed. 67 m&l for replacement of unsv hydraulic door closer assembly of air shower complete all as specified and directed. 68 m&l for repair of printed circuit board of air shower for 2 persons taking down and re fixing of the same complete all as specified and directed. 69 m&l for servicing, rewinding of stabilizer 4 kva with copper winding as per existing gauge & turns including replacement of defective items compete all as specified and directed. 70 m&l for servicing, rewinding of stabilizer 5 kva with copper winding as per existing gauge & turns including replacement of defective items compete all as specified and directed. 71 m&l for replacement of unsv condenser cooling coils of split type ac up to 3 tr cap with new copper coil including taking out unsv condenser coil complete all as specified and directed. 72 m&l for replacement of unsv motor of air curtain as per existing make and modelincluding replacement of bush, baring etc as reqd at site complete all as specified and directed. 73 m&l for replacement of unsv drain flexible pvc pipe of split type ac complete all as specified and directed. 74 m&l for replacment of unsv hepa filters having 99.97% dn to 0.3 mic of airshower as per existing size complete all as specified and directed. 75 m&l for replacment of emergency release switch of air shower including making proper connections complete all as specified and directed. 76 m&l for replacment of unsv pre filtersof air shower flange type having efficiency 95% dn to 10 mic as per existing size complete all as specified and directed. 77 m&l for servicing of vrf system53 kw having 03 nos outdoor unitsby checking all parts, repair to electrical connection, cleaning of air filter, cooling coil, fan / blower and replacing minor u / s parts like bushes, nut bolts etc complete all as specified and directed. 78 m&l for replacment of unsv rotational moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) two layer isi marked hoisted and fixed in position all as specified in ssr pt i of capacity 1000 ltrs complete all as specified and directed. 79 m&l for replacment of condensor coil blower motor of water cooler 40 to 150 ltr / refrgerator 190 to 385 ltr capacityas per existing type & model complete all as specified and directed. 80 m & l attending emergent complaints i.e pertaining to air conditioners any type, water cooler any type, refrigerator any type including carrying out minor repairs including replacing necessary capacitors, thermostat, relays, pcb etc as required to make the system in order / functionalcomplete all as specified and directed.note : rate of spare parts shall be measured and paid separately under relevant items. minor parts deemed to include in cost of item. 81 m & l fortaking out existing insulation& replace with new insulation 24 kg / cu mt density & cover with glass wool of 50 mm thickness & 26 gauge aluminium clading complete all as specified and directed. 82 m&l for taking out existing& supply installation , testing& commissioning ofof pn 1.6 , 3 way modulating valve 100 mm dia forahu, s chilled water coil application complete with motor actuator, thermostat, voltage transformer, flanges, nuts bolts, gaskets duy insulated with 50 mm thick tf quality eps & covered with 12 mm sand cement plasterincluding copper power & controle cable of suitabe sizecomplete all as specified and directed. 83 m&l for replacement of microprosser controller model 33 tr scroll v3a type delux, range 16 / 4 / 2, aux supply 15 v ac complete all as specified and directed.existing make : softhard 84 m&l for replacement ofmicroprocessor model:vlrp single v4, type delux, range 6 / 5 / 4, aux supply 13 v ac, complete all as specified and directed.existing make : softhard 85 m&l for replacement ofmicroprocessor model 44 tr scroll v3a, type delux, range 17 / 5 / 2, aux supply 15 v ac complete all as specified and directed.existing make : softhard 86 m&l for replacement ofmicroprocessor model screw single 100 tr, v3 type delux, range 7 / 7 / 4 aux supply 15 v ac complete all as specified and directed.existing make : softhard 87 m&l for replacement of microprossermodel 33 tr scroll v2a type delux, range 16 / 4 / 2, aux supply 15 v ac complete all as specified and directed.existing make : softhard 88 m&l for replacement of microprossermodel 22 tr scroll v2a type delux, range 16 / 4 / 1, aux supply 15 v ac complete all as specified and directed. existing make : softhard 89 m&l for replacement of microprosser controller model ec, type m2vpd, range 5 30a, aux supply 230v ac, special 5 sec curve mpd complete all as specified and directed. existing make : softhard 90 m&l for replacement of microprosser controller model ec, type mvpd, range 80 440 a, aux supply 230v ac, special 5 second curve mpd complete all as specified and directed.existing make : softhard 91 m&l for replacement of microprosser controller model ec, type mvpd, range 5 30a, aux supply 230v ac, special 5 second curve mpd complete all as specified and directed.existing make : softhard 92 m&l for replacement of microprosser controller model μ vpd ( split ) ec, range 360v 500v ac ( normal 415ac ) , aux supply 230v ac, complete all as specified and directed.existing make : softhard 93 m&l for replacement of microprosser controller model m3 pd type μ mpd, range 5 to 30 amps aux supply 13 vac, special 5 sec, complete all as specified and directed.existing make : softhard 94 m&l for duct thermal insulation class o nitrile rubber based thermal insulation 19 mm thick with treated woven glass fibre covering of 0.18mm thick, density of 200+20 gsm, tensile strength 275+ 25 kg / mm for exposed to sun application ( green colour ) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material, cleaning the duct surface complete all as specified by oem & directed by engineer in charge.existing make armacell / vidoflex / eurobatex. 95 m&l for taking out carefully damaged ducting including all accessoriescomplete all as specified and directed. 96 supply assembly and erection of gi sheet with c &ss rectangular / square duct made out of l shaped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size22 gaugeall as specified and including with required scaffolding work to install the ducts at site complete all as specified and directed.note : ( i ) for measurementonly the final finished area in sqmm shall be measured. ( ii ) venes, splitters, ms frames for joints, flanges, access doors etc shall not be measured seprately .these shall be treated as part of duct work. ( iii ) only external angle iron / c channelduct support shall be measured and paid separatly. 97 s&f in replacement of blower belt of ahu / compressor belts as per existing model and type isi marked including re alignment of the motor and blower if required for proper tension of belts complete all as specified and directed. 98 m&l for replacment of unsv centrifugal monoset pump set suitable for working on 415v three phase 50 hz ac supply having 2900 rpm, 5.5kw / 7.5hp, discharge 14 lps at 28 mtr head, del size 80x65mm, class b insulation, existing model no kd6 830make kirloskar ( 2402 sqn ) complete all as specified and directed. 99 s&frotational mounted polyethylene water storage tank ( cylindrical vertical with closed top ) hoisted and fixed including necessaryfittings required for inlet, outletwater pipeconnection ( such asbarrel nipple, union, tee, drain plug, air vent pipe for outlet line etc. ) complete all as specified and directed for following capacity : 100 ( a ) 2000 ltr cap 101 ( b ) 5000 ltr cap 102 supply, installation, testing & commissioning of 100 mm dial type pressure gauge with appropriate range & ss valvesand ss tubing complete all as specified and directed. 103 supply, installation, testing & commissioning of set of 150 mm dial type temp gauge with appropriate range & ss valvesand ss u tubing complete all as specified and directed. 104 m&l for replacement of old unsv outdoor unit of split typewith ac 3 star rating, 1.5 tr cap having copper tubing, high eer rating compressor ( for gas r 407 / 410 / 32 ) , blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and chargingsuitable refrigerant gasto achieve desired cooling effect and testing complete all as specified and directed.existing make blue star / voltas / hitchin / daiken 105 m&l for replacement of unsv indoor unit of split type ac 1.5 tr complete having 3 star rating suitable for ( r 407 / 410 / 32 ) gas complete all as specified and directed.existing make voltas / blue star / hitachi / daiken 106 supply and lay and jointing tubing medium grade galvanised iron pipes, isi marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches complete all as specified and directed.of size : ( a ) 25 mm bore 107 s & f gun metal globe or gate valves with iron wheel headscrewedbothend for iron pipe and fixed complete all as specified and directed. ( a ) 25 mm dia bore...

Pune Municipal Corporation - Maharashtra

34235925 tender for ambassadar, indica sumo indigo, force traveller, tata winger ac repairing with spare parts 1 refrigerant gas fiiling ( charging ) 2 ambassador 3 indica / vista / tiago 4 indigo / manza 5 sumo victa / gold / grande 6 tata winger 7 ambulance ( force traveller / tata winger ) 8 pressure testing and oil change 9 ambassador 10 indica / vista / tiago 11 indigo / manza 12 sumo victa / gold / grande 13 tata winger 14 ambulance ( force traveller / tata winger ) 15 change of suction pipe 16 ambassador 17 indica / vista / tiago 18 indigo / manza 19 sumo victa / gold / grande 20 tata winger 21 ambulance ( force traveller / tata winger ) 22 change of discharge pipe 23 ambassador 24 indica / vista / tiago 25 indigo / manza 26 sumo victa / gold / grande 27 tata winger 28 ambulance ( force traveller / tata winger ) 29 change of liquid pipe 30 ambassador 31 indica / vista / tiago 32 indigo / manza 33 sumo victa / gold / grande 34 tata winger 35 ambulance ( force traveller / tata winger ) 36 overhauling of unit / full checking of unit 37 ambassador 38 indica / vista / tiago 39 indigo / manza 40 sumo victa / gold / grande 41 tata winger 42 ambulance ( force traveller / tata winger ) 43 change of compressor belt 44 ambassador 45 indica / vista / tiago 46 indigo / manza 47 sumo victa / gold / grande 48 tata winger 49 ambulance ( force traveller / tata winger ) 50 compressor bracket repair 51 ambassador 52 indica / vista / tiago 53 indigo / manza 54 sumo victa / gold / grande 55 tata winger 56 ambulance ( force traveller / tata winger ) 57 change of compressor bracket, all bolts etc 58 ambassador 59 indica / vista / tiago 60 indigo / manza 61 sumo victa / gold / grande 62 tata winger 63 ambulance ( force traveller / tata winger ) 64 change of compressor backplate and gasket 65 ambassador 66 indica / vista / tiago 67 indigo / manza 68 sumo victa / gold / grande 69 tata winger 70 ambulance ( force traveller / tata winger ) 71 change of setting pulley 72 ambassador 73 indica / vista / tiago 74 indigo / manza 75 sumo victa / gold / grande 76 tata winger 77 ambulance ( force traveller / tata winger ) 78 rectification of wiring 79 ambassador 80 indica / vista / tiago 81 indigo / manza 82 sumo victa / gold / grande 83 tata winger 84 ambulance ( force traveller / tata winger ) 85 replacing of pressure switch 86 ambassador 87 indica / vista / tiago 88 indigo / manza 89 sumo victa / gold / grande 90 tata winger 91 ambulance ( force traveller / tata winger ) 92 replacing of switch 93 ambassador 94 indica / vista / tiago 95 indigo / manza 96 sumo victa / gold / grande 97 tata winger 98 ambulance ( force traveller / tata winger ) 99 replacing of charging valves o rings 100 ambassador 101 indica / vista / tiago 102 indigo / manza 103 sumo victa / gold / grande 104 tata winger 105 ambulance ( force traveller / tata winger ) 106 replacing of compressor 107 ambassador 108 indica / vista / tiago 109 indigo / manza 110 sumo victa / gold / grande 111 tata winger 112 ambulance ( force traveller / tata winger ) 113 replacing of expansion valve 114 ambassador 115 indica / vista / tiago 116 indigo / manza 117 sumo victa / gold / grande 118 tata winger 119 ambulance ( force traveller / tata winger ) 120 replacing of receiver drive 121 ambassador 122 indica / vista / tiago 123 indigo / manza 124 sumo victa / gold / grande 125 tata winger 126 ambulance ( force traveller / tata winger ) 127 replacing of cooling coil 128 ambassador 129 indica / vista / tiago 130 indigo / manza 131 sumo victa / gold / grande 132 tata winger 133 ambulance ( force traveller / tata winger ) 134 fitting of complete a / c unit 135 ambassador 136 indica / vista / tiago 137 indigo / manza 138 sumo victa / gold / grande 139 tata winger 140 ambulance ( force traveller / tata winger ) 141 condenser 142 ambassador 143 indica / vista / tiago 144 indigo / manza 145 sumo victa / gold / grande 146 tata winger 147 ambulance ( force traveller / tata winger ) 148 condenser fan 149 ambassador 150 indica / vista / tiago 151 indigo / manza 152 sumo victa / gold / grande 153 tata winger 154 ambulance ( force traveller / tata winger ) 155 blower motor 156 ambassador 157 indica / vista / tiago 158 indigo / manza 159 sumo victa / gold / grande 160 tata winger 161 ambulance ( force traveller / tata winger ) 162 resistance amplifier 163 ambassador 164 indica / vista / tiago 165 indigo / manza 166 sumo victa / gold / grande 167 tata winger 168 ambulance ( force traveller / tata winger ) 169 a / c filter 170 ambassador 171 indica / vista / tiago 172 indigo / manza 173 sumo victa / gold / grande 174 tata winger 175 ambulance ( force traveller / tata winger ) 176 dashboard grill / vents 177 ambassador 178 indica / vista / tiago 179 indigo / manza 180 sumo victa / gold / grande 181 tata winger 182 ambulance ( force traveller / tata winger ) 183 cooling coil body 184 ambassador 185 indica / vista / tiago 186 indigo / manza 187 sumo victa / gold / grande 188 tata winger 189 ambulance ( force traveller / tata winger ) 190 flushing 191 compressor 192 condenser 193 cooling coil 194 whole system...

Ministry Of Power - Maharashtra

34230025 bids are invited for m1060740604_ r 407 c refrigerant gas (q3) , m1060731015_ r 410a refrigrant gas (q3) total quantity : 660...

Western Railway - Maharashtra

33926769 supply of hfc refrigerant gas r 407 c in capacity of cylinder 08kgs each for rmpu of lhb ac coaches.hfc refrigerant gas r 407 c in capacity of cylinder 08kgs each for rmpu of lhb ac coaches., hfc refrigerant gas r 407 c in capacity of cylinder 08kgs each for rmpu of lhb ac coaches. ( material to be procured from oem or its authorized dealer and may please submit proof of purchase ) . senior section maharashtra 160.00 kg...

Pimpri Chinchwad Municipal Corporation - Maharashtra

33843553 supply installation testing and commissioning screw type air cooled chillers complete with spring loaded anti vibration mounts rigging to ground floor refrigerant gas and oil etc, electrical power panel for airconditioning system...

Central Railway - Maharashtra

33806546 supply of refrigerant gas ( fleron 134a ) ( 1, 1, 1, 2 trefrigerant gas ( fleron 134a ) ( 1, 1, 1, 2 t, refrigerant gas ( fleron 134a ) ( 1, 1, 1, 2 tetrafluoroethane ) cf3ch2f in companys 62 kgs. returnable cylinder. dycmm ( cwe ) , matunga , maharashtra 62.00 kg => limited...

Central Railway - Maharashtra

33711359 supply of r 32 refrigerant gasr 32 refrigerant gas, r 32 refrigerant gas with 35 kg each cylinder. i.e in total 02 nos. cylinders ( cylinders are non returnable ) make / brand freon, floron, mefron only. se / ed ( ac and r ) maharashtra 70.00 kg...

Western Railway - Maharashtra

33704169 supply of refrigerant gas r 407c.refrigerant gas r 407c., refrigerant gas r 407c suitable for rmpu of lhb type ac coaches....

Directorate Of Purchase And Stores - Maharashtra

33431835 supply of 1.5 ton inverter window ac 1.5 ton inverter window ac , supply, installation & commissioning and warranty of 1.5 ton inverter window ac with following additional specifications: a. 5 star energy rating as per as per bee guidelines b. condenser coil, evaporator coil, and connecting tubes made of copper c. noise level less than 55 ( db ) d. r32 used as refrigerant gas e. stabiliser free operation f.anti corrosive blue fins g.humidity control, turbo cool h. compressor with inverter technology i. min 2 year oem warranty...

Military Engineer Services - Maharashtra

33283694 maintenance of summer appliance including replacement of defective spares and allied works and rep replcmnt of intrnl wiring incd fitting fixture with connected accessories of ac installations tunir and out side area under age emii ge nw karanja 1 servicing / preventive maintenance of the following equipments of different capacitiesby carrying out regular maintenance such aschecking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning washing with suitable cleaning agent / chemical using vacuum cleaner, replacement of rubber wheels, bolts & nuts, screws check nuts, pvc sleeves and thimbles, and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularily through out the contract period all as specified and as directed. 2 ( a ) 1.5 / 2.0 ton capacity window type acs 3 ( b ) 1.5 / 2.0tons capacity split type acs 4 ( c ) 2.0 / 3.0tons capacity casset type acs 5 ( d ) water coolers ofany capacity 6 ( e ) refrigerators capacity 165 to 310 ltr 7 ( f ) deep freezers up to 400 ltr 8 ( g ) ice making machine 250 ltr 9 taking out sealed / old burnt compressor of window type ac 1.5 ton of approved make and s&f new sealed compressoras per reciprocating type suitable for 1.5 ton capacity ac and connecting up suction and discharging pipe line with gas welding complete all as specified and directed by engineer in charge. make: m / s kirloskar / m / s carrier / m / s voltas / m / s bluestar or as approved by ge. 10 all as per item no. 2.00 butsplit type ac 1.5 toncapacity complete all as specified and as directed 11 all as per item no. 2.00 but split type ac 2 toncapacity complete all as specified and as directed. 12 taking down split type ac and taking out rotary type sealed compressor of split type ac 1.5 ton capacity of approved make and s&f new sealed rotary type compressor suitable and discharging pipe line with gas welding and refixing the repaired ac in its original position complete all as specified and directed by engineer in charge 13 all as per item no. 5.00 but split ac 2.0 ton capacity complete all as specified and as directed. 14 s & f inrepairs copper cooling coil assembly for 1.5 tonair conditioner of approved makeincluding testing and commissioning complete all as directed by engineer in charge. 15 s & f in repairs of copper cooling coil assembly for 2.0 ton air conditioner of approved make, commissioning complete all as specified and as directed. 16 s & f inrepairscondenser coil assembly suitable for 1.5 tonair conditioner including testing and commissioning complete all as specified and as directed. 17 s & f inrepairscondenser coil assembly suitable for 2.0 tonair conditioner including testing and commissioning complete all as specified and directed. 18 supply & fixing in replacementof unserviceable split type air conditioner indoor unit suitable for 1.5 / 2.0 ton invertor type as per existing make & sizecomplete with remote assy all as specified & directed by engr in charge.make : carrier / hitachi / voltas / daikin / panasonic / bluestar 19 note for item nos 2.00 to 11.00 : ( a ) contractor will provide guarantee for at least one year for replaced compressor unit. compressor should be sealed with original manufacturers packing having reputed make all as approved by engineer in charge. ( b ) gas charging will be measured and paid separately under relevant items as described. gas charging will be measured and paid only once for entire contract period while initial charging of compressorand subsequent leakage / topping up shall be made good by the contractor at his own cost through out the contract period. 20 s & f in repairs running capacitor 36 mfd, 3 pole & 2 pole suitable for 1.5 ton window / split type air conditioner. make m / s asian / m / s unistar / m / s epcos / m / s electro all as specified and as directed. 21 s & f inrepairsrunning capacitor 45 mfd, 3 pole & 2 pole suitable for 2.0 ton window / split type air conditioner. make m / s asian / ms unistar m / s epcos / m / s electro all as specified and as directed. 22 s & f inrepairs starting capacitor 100 to 120 mfd suitable for 1.5 ton window / split type air conditioner. make m / s asian / m / s unistar / m / s epcos / m / s electro all as specified and as directed . 23 s & f inrepairsstarting capacitor 100 to 150 mfd suitable for 2.0 ton capacity window / split type air conditioners. make m / s asian / ms unistar m / s epcos / m / s electro complete all as specified and as directed. 24 s&f in repairs starting relay suitable for 1.5 ton / 2.0 ton / 3.0 ton of split / window type ac make m / s sriram / m / s renutral all as specified and as directed. 25 s & f inrepairsof thermostat switch for window / split type air conditioner of 1.5 / 2.0 / 3.0 ton capacity. make m / s renutral / m / s denfoss all as specified and as directed. 26 m & l for gas charging r 22 in window type ac 1.5 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed. 27 all as per item no 19.00 but 2.0 ton capacity complete all as specified and as directed. 28 all as per item no 19.00 but split type ac 1.5 / 2.0 / 3.0 ton capacity complete all as specified and as directed. 29 taking down window type / split type air conditioner of any type / make / capacity from site ( either in ground / any floor ) , transporting to work site opening top and side cover, dismantling all electrical controls and components and cleaning the whole unit with electric blower and spray cleaning with water, descaling with acid in both side of cooling coil and components, refixing the covers and making electrical connections, installation of the machine in same location, testing, commissioning complete all as specified and as as directed.note : spares required for repair will be measured and paid seperately under relevent item of this schedule. 30 shifting of split type air conditioner of any type and make, up to 2 tr from existing location to other location and installingindoor and outdoor units as directed including provision of necessary brackets ( l type ) clamps, gi nuts, bolts and washers etc for fixing of indoor / outdoor units including topping up of refrigerant gas and nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed.note : ( i ) pvc pipe for protection , drain pipe , control cable, extra copper tubing of any sizefor suction / discharge will be measured and paid separately. ( ii ) gas charging will be measured and paid only once for entire contract period while initial charging of compressorand subsequent leakage / topping up shall be made good by the contractor at his own cost. 31 shifting of window type air conditioner of any type and make, up to 2 tr from existing location to other location and installingas directed, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, gi nuts, bolts and washers etc for fixing of ac, and making good disturbed surface of walls and windows complete all as specified & directed. note : ( i ) pvc drain pipe , control cable where required will be measured and paid separately. 32 s & f in repairselectric wiring kit ( pcb ) suitable for 1.5 ton / 2.0 ton window type / split type air conditioner of any make and type complete all as specified and as directed.note: new pcb shall be as per the existing one. 33 supply in replacement remote assembly cordless as per existing make and size window / split type acs as per ac make complete as specified. 34 taking down corroded body base tray etc of window / split type acof 1.5 ton / 2 ton capacity and replacement of body base tray etc made out of 18 swg mild steel and other portion of mild steel sheet of 20 swg including motor mounting frame fix with nuts and bolts of suitable size and painting with one coat of black enamel paint and necessary insulation complete all as specified and as directed. note : unit rate quoted shall also deemed to include for reassembling. 35 s & f inrepairsof fan blade of motor for window type ac of capacity 1.0 ton / 1.5 ton / 2.0 ton of make m / s asian or equivalent complete all as specified and as directed. 36 s & f in repairsblower fan motor for 1.0 ton / 1.5 ton / 2.0 ton capacity air conditioners including testing, complete all as specified and as directed. make:blower fan motor shall be as per the existing one. 37 s & f inrepairsblower drum suitable for window type ac of capacity 1.0 ton / 1.5 ton / 2.0 ton completeall as specified and as directed. note: blower drum shall be as per the existing one. 38 s & f inrepairsfront cover grill suitable for window type air conditioner of capacity 1.0 ton / 1.5 ton / 2.0 ton, complete all as specified and as directed 39 s & f inrepairsouter cover suitable for window type air conditioner of any capacity complete all as specified and as directed. 40 s & f inrepairsblower motor capacitor 4 mfd suitable for 1.5 window type air conditioner complete all as specified and as directed. 41 s & f in repairsblower motor capacitor 10 mfd suitable for 1.5 ton split type air conditioner complete all as specified and as directed. 42 s & f inrepairsblower motor capacitor 15 mfdsuitable for 2.0 / 3.0 ton split type air conditioner complete all as specified and as directed. 43 supply, fixing, clamping and jointing copper tubing of standard size 1 / 2, 5 / 8 for suction line and liquid discharge line of suitable size 1 / 4 duly insulated with suitable insulation materials including making hole in any type of wall for passing through pipe andmaking good to the disturbed surface as in replacement and colour matching as per existing shade, complete all as specified and as directed. 44 supply and fixing in replacement cable pvc insulatedpvc unsheathed, multistranded, 1100volts grade ( isi marked ) 3 core 2.5 sq mm with flexible copper conductor suitable forsplit type ac and window type ac complete all as specified and as directed. make: havells, polycab, plaza. 45 supply and fixing suitable size pvc pipe, heavy duty for drain out of condensing water of split type air conditioner including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe etc to match the existing surface with original specifications complete all as specified and as directed. 46 s & f inrepairssynthetic air filter suitable for split / window type air conditioner any capacity complete all as specified and as directed 47 servicing, cleaning of solar water heater system by dismantling inlet and outlet connection, washing with suitable cleaning agent castic soda, arresting leakage and refixing the same after replacement of bush, nut, bolts, washers, painting of rusted surfaces if any making serviceable to desired satisfaction level complete all as specified & directed by engineer in charge. 48 water coolerstaking down sealed compressor of water cooler of approved make of capacity 40 / 80 ltrs and supply and fixing in replacement company repaired sealed unit caj 3612 or ae 4440 of m / s kirloskar or equivalent and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas including testing & commissioning complete all as specified and as directed. 49 all as per item no 41.00but capacity 60 / 120 ltrs complete all as specified and as directed. make : bpk kce 461 of m / s kirloskar or equivalent in ps. 50 s & f in replacement starting capacitor 40 / 60 mfd complete all as specified and as directed. make m / s asian, m / s unitstar, m / s tibcon, m / s telsa 51 s & f inrepairsstarting capacitor 80 / 100 mfdcomplete all as specified and as directed. make – m / s asian, m / s unistar, m / s tibcon, m / s telsa. 52 s & f inrepairsof thermostatic switch for water cooler complete all as specified and as directed. make – m / s renutral , m / s ind foss, m / s annapurna ( aes ) . 53 s&f inrepairs of condenser fan motor 1 / 35 hp 230 volt ac single phase suitable for water cooler all as specified and as directed.make – m / s crompton greaves, m / s khetan, m / s ave, m / sface master. 54 all as per item no 46.00but 1 / 83 hp complete all as specified and as directed. 55 s & f inrepairsrelay for water cooler of capacity 40 / 80 litres and 60 / 120 litres capacity all as specified and as directed. 56 s&f inrepairsof fan blade suitable for existing water coolerof any capacity, approved make and type complete all as specified and as directed. 57 s & f in repairs push cock / lifting cock of 15 mm dia chromium plated suitable for water cooler of capacity 40 / 80 litres & 60 / 120 litres complete all as specified and as directed. 58 detecting the gas leakage, rectifying the defects, vacumizing and charging fresh refrigerant gas and commissioing and testing the water cooler of capacity upto60 / 120 litre capacity , complete all as specified and as directed. 59 s & f inrepairs of water tray stainless steelgrade ss 304 of 40 / 80 ltr capacity complete all as specified and as directed. 60 all as per item no 52.00 but capacity 60 / 120 ltrs complete all as specified and as directed. 61 s&f inrepairsof rubber packing and hinges of top cover of water cooler of any makeand capacity complete all as specified and as directed. 62 s & f in repairs15 mm dia isi marked float valvebrass of make m / s prayag / m / s rojari or equivalent, all as specified and as directed. 63 s & f inrepairsover load protector for watercooler of any capacity complete all as specified and as directed. 64 s & f in replacement pvc connecting pipe with brass nuts& washers at both ends oflength not exceeding 60 cm for water connection of water coolers complete all as specified and as directed. 65 s & f suitable size pvc drain pipe flexible heavy duty with necessary saddles and fitting for drain out water from water cooler complete all as specified and as directed. 66 refrigeratorstaking down sealed compressor of 165ltr / 175 ltrs capacityof refrigerator of approved make and type and replacement of hermetically sealed unit of compressor of samesize and type and capacity , connecting sealed unit and dischargepipe with gas welding and soldering rod complete all specified and as directed. 67 all as per item no 59.00 but 286 / 300 / 310 ltr capacitycomplete all specified and as directed. 68 s & f inrepairs thermostat switch for refrigeratorof any capacity, complete all as specified and as directed. 69 s&f inrepairs over load relay / protector suitable for high / low speed refrigerators of unit of compressor 165 / 230 / 286 / 300 / 310 ltr capacityof refrigerator all as specified and directed. make: m / s renutral / m / s sriram / m / s kelvinator / m / s godrej / m / s kirloskar 70 s&f lamp 15 watt or any watt screw / pin type suitable for approved make and capacity refrigerator complete all as specified and directed by e in charge. make: m / s godrej / m / s kelvinator. 71 m&l for charging of refrigeratorrefrigerant gas r 134a / r 410a suitable gas after vaccumising / pressure and leaking including flushing the system in the refrigerator of any make of 165 litre cap all as specified and as directed. note: gas charging for a particular machine will be measured and paid only once for entire contract period while first / initial charging and subsequent leakage / topping up shall be made good by the contractor at his own cost. 72 all as per item no 64.00but 230 / 286 / 300 / 310ltr capacitycomplete all specified and as directed. 73 s & f inrepairsmagnetic gasket for refrigeratorof165 / 175 / 286 / 300 / 310 litres capacity all as specified and as directed. 74 s & f in repairs relay for refrigeratorof capacity 165 to 310litresall as specified and as directed. 75 supply and fixing in replacement of unservicable freezer chamber existing make & size forupto 165 to 195 ltr capacity refrigerator direct cool complete all as specified & directed. 76 supply and fixing in replacement of unservicable freezer chamber existing make & size for refrigerator frost free double door incl heater, blower etc for 285 to 310 litres capacity. 77 m&l in replacement of unservicable condenser for refrigerator as per existing make &any capacity, complete all as specified and directed. 78 m&l for disconnecting the electrical and refrigerant connections of defective compressor unit ofdeep freezer of capacity upto 400 ltrsand replacing with new compressor ( refurbrished by oem ) , connectingthe sealed unit both electrical and refrigerant connections including charging refrigerant gas after nitrogen pressure test to find out leakage as requiredcomplete all as specified & directed. make of compressors : kirloskar complan / tecumseh / carrier. 79 supply & fixing in replacementof unservicable condenser fan motor box typefor deep freezer of any capacity / size, complete all as specified and directed. make – m / s crompton greaves, m / s khetan, m / s ave, m / sface master. 80 aircurtainstaking down defective / unserviceable air curtain of existing capacity and existing make, transporting to company authorized outlet, collecting company repaired air curtain of same make and transporting back to site, refixing at original posotion complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and directed by engr in charge. 81 m&l for replacement ofwater purifier filter kit including repair / replacement of defective parts such as filters, solenoide valve, pump, switch complete of machine all as directed by engr in charge. 82 m& l for repair of voltage stabilizer of capacity 5 kva including replacement of burnt out transformer and all accessories complete all as directed by engr in charge 83 internal electrification taking down copper / aluminium point wiring ( light, fan, socket or power ) complete, including fixture and fittings such as switches, ceiling roses, pendants, lamp holders, regulators, sockets, light fitting any type etc complete. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by eng. in charge 84 taking down mcb with sheet metal enclosure, main switch, db etc and making good disturbed surfaces to match with existing surfaces. 85 taking down sub main wiring of any size / capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces 86 m&l for point wiring with1100 volts, grade 1.5 sqmm. ( nominal area ) , pvc insulated but unsheathed multistranded copper conductor single core frls cable drawn through and including non metallic medium duty rigid pvcconduit ( medium duty ) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron / steel suction boxof thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 sqmm. ( nominal area ) single core frls, pvc insulated 1100 volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified and directed by engr. in charge of following. 87 ( a ) one light / bell / exhaust fan pointcontrolled by one one way switch. 88 ( b ) one ceiling fan point controlled by one one way switch through regulator. 89 ( c ) one three pin 5 amp socket on same board with other switches. 90 ( d ) one three pin 5 amp socket on independent board. 91 all as per item no.79 above but with 2.5 sqmm. ( nominal area ) wire / cable for phase and neutral for one 3 pin 15 amp socket on independent board including one 1.5 sqmm pvc insulated unsheathed multi stranded copper conductor cable, frls 1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by eng. in charge. 92 s&f switch piano flush, button type 5 amp sp 250 volt ac complete all as specified & directed. 93 s&f switch piano flush button type 15 amps sp 250 voltac complete all as specified & directed. 94 s&f socket outlet multipurpose 3 pin 5 amp and 2 pin 5 amps 250 v ac complete all as specified & directed. 95 s&f socket outlet 2 in1, 3 pin 5 and 15 amp flush type 250v ac complete all as specified & directed. 96 s&f ceiling rose surface bakelite 3 terminals of size 65x25mm. complete . 97 s&f step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200 / 1400 mm sweep 230 volts ac. 98 s&f lamp holder pvc / polycarbonate type with led lamp 9 / 10 watt complete all as specified & directed. 99 s&f wall mounted led tube light fitting 1x20 / 22 watts extruded aluminiumpolycarbonate covers pf 0.9 and above operating voltage 140v 270v colour temp 3000 k / 6500k & lumen input output 95 lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23 / 0.0076 fixed on wall / roof complete all as specified and directed. 100 s&f sheet metal enclosures 240 voltwith suitable rated bus bar for double door 8 way ip 43 dbs mounting flush on wall / concealed and making good distubed surfaces incl taking out unserviceable db any capacity. complete all as specified and directed by engr in charge. make: legrand / l&t / schneider. 101 s&f sheet metal enclosures 240 voltwith suitable rated bus bar for double door 4 way ip 43 dbs mounting flush on wall / concealed and making good distubed surfaces incl taking out unserviceable db any capacity. complete all as specified and directed by engr in charge. make: legrand / l&t / schneider. 102 supply and fixing wall mounted type sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with and including mcb spn 20 amp c series 10 ka mounted on din rail channel and suitable plug complete all as specified and directed by engr in charge make: legrand cat no 5078 14 or eqvt in l&t / simens / schneider. ( note : item rate including all items ie base box, plug, socket , mcb etc complete ) 103 s&f mcb spn240 volt 10 ka40 amp c series conforming to iscomplete all as specified & directed.make: legrand / l&t / schneider. 104 s&f mcb single pole240 volt, 10 ka, 40 amp, c series confirming to is complete all as specified and directed.make: legrand / l&t / schneider. 105 m&l for sub main wiringwith 2 single core pvc insulated unsheathed cable 1100 volts grade heavy duty copper conductor multistranded of size 4 sqmm ( nominal area ) drawing in and including 20 mm dia or higher medium dutypvc concealed conduit and conduit accessories and fittings. including one single core green colour pvc insulated unsheathed cable copper conductor multistranded of size 4 sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed....

Directorate Of Purchase And Stores - Maharashtra

33264794 refrigerant compressed air dryer refrigerant compressed air dryer , safe delivery, supply, installation & commissioning and warranty of refrigerant compressed air dryer • inlet air flow capacity 100 cfm ± 10% • max working pressure – 13 bar • normal working pressure – 8 bar • pressure drop ( max. ) 0.3 bar or less • pressure due point + 30 c • electrical power supply 230v / 1ph / 50hz • power consumption 1 kw or less • controller electronic control with fault display • end connection – 1” bsp • refrigerant gas – eco friendly refrigerant • weight ( approx. ) 70 kg ± 10% • dimensions – 525 ( l ) x 500 ( w ) x 700 ( h ) ± 10% • standard warranty – 12 months or more air filters required suitable prefilter and oil filter in compressed air line. pre filter will be installed before refrigerant air dryer and oil filter is after refrigerant air dryer • pre filter solid particle removal 1 micron or larger initial pressure loss – 0.1 bar or less end connection – 1” bsp • oil filter oil removal – 0.01 mg / m3 filtration initial pressure loss – 0.1 bar or less end connection – 1” bsp...

Inter-University Centre For Astronomy And Astrophysics - Maharashtra

33258580 supply, installation, testing and commissioning of hiwall split ac units with all inverter compressor consisting of ( 1 ) condensing unit with reputed make hermetically sealed dc twin / swing rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg c. ( 2 ) indoor unit consisting of 3 / 4 row cooling coilblower with motor, filters, drain pan & casing. the evaporator shall be complete with expansion valve & distributor. ( 3 ) the minimum acceptable value of coefficient of performance ( cop ) of the offered split ac model shall be not less than 3.85 for 1.5 tr on 100% ( 5.0 kw ) and and 3.90 for 1.8 / 2 tr ( 6 kw ) hiwall split ac at rated capacity with 35 deg. c outdoor and 19 deg. c wet bulb conditions. the cop confirmation should be done by the oem on their authentic letter head. ( 4 ) the outdoor unit shall be factory tested and filled with first charge of refrigerant r 32 / r 410a before delivering at site. ( 5 ) necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. ( 6 ) interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. the suction lines shall be insulated with closed cell nitrile rubber tube insulation. ( 7 ) the units shall be with individual cordless remote. ( 8 ) the units shall be suitable for operation on 220 / 240 volts, 1 ph., 50 hz, 3 wire a.c. supply. 1.8 / 2 tr capacity ( 6 kw & above cooling capacity ) 5 star, inverter hiwall split ac unit , supply, installation, testing and commissioning of hiwall split ac units with all inverter compressor consisting of ( 1 ) condensing unit with reputed make hermetically sealed dc twin / swing rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg c. ( 2 ) indoor unit consisting of 3 / 4 row cooling coilblower with motor, filters, drain pan & casing. the evaporator shall be complete with expansion valve & distributor. ( 3 ) the minimum acceptable value of coefficient of performance ( cop ) of the offered split ac model shall be not less than 3.85 for 1.5 tr on 100% ( 5.0 kw ) and and 3.90 for 1.8 / 2 tr ( 6 kw ) hiwall split ac at rated capacity with 35 deg. c outdoor and 19 deg. c wet bulb conditions. the cop confirmation should be done by the oem on their authentic letter head. ( 4 ) the outdoor unit shall be factory tested and filled with first charge of refrigerant r 32 / r 410a before delivering at site. ( 5 ) necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. ( 6 ) interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. the suction lines shall be insulated with closed cell nitrile rubber tube insulation. ( 7 ) the units shall be with individual cordless remote. ( 8 ) the units shall be suitable for operation on 220 / 240 volts, 1 ph., 50 hz, 3 wire a.c. supply.1.5 tr capacity ( 5 kw cooling capacity ) 5 star, inverter hiwall split ac unit , refrigerant copper piping 18 / 20 gauge with 19 mm thick o class insulation 5 / 8 & 3 / 8 or 1 / 2 & 1 / 4 / suitable for above machines , refrigerant copper piping 18 / 20 gauge with 19 mm thick o class insulation drain piping in hard cpvc with all fittings, supports and clamps upto 50 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe. , refrigerant copper piping 18 / 20 gauge with 19 mm thick o class insulation set of power & control cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. forhiwall split ac. , refrigerant copper piping 18 / 20 gauge with 19 mm thick o class insulation ms structural work and special supporting structure for condensing units, powder coated , refrigerant copper piping 18 / 20 gauge with 19 mm thick o class insulation core cutting in wall / slab for ac piping ( pleaser refer tender document for details ) . => limited...

Western Railway - Maharashtra

33247002 supply of hermitically sealed scroll compressorhermitically sealed scroll compressor,hermitically sealed scroll compressor suitable for r 407c refrigerant gas,working on 415vac 50hz confirming to rdso spec no rdso/pe/spec/ac/0061 2005(rev 1)or lastest as per model no.zr 61 kce tfd 522 of m/s emerson make. => limited...

Western Railway - Maharashtra

33194846 supply of hermitically sealed scroll compressor suitable for r 407c refrigerant gas,working on 415vac 50hz confirming to rdso spec no rdso/pe/spec/ac/0061 2005(rev 1)or lastest as per model no.zr 61 kce tfd 522 of m/s emerson make. as per drg.no. specn: rdso spec.no:rdso/pe/spec/ac/0061 2005(rev 1) or latest.hermitically sealed scroll compressor suitable for r 407c refrigerant gas,working on 415vac 50hz confirming to rdso spec no rdso/pe/spec/ac/0061 2005(rev 1)or lastest as per model no.zr 61 kce tfd 522 of m/s emerson make. as per drg.no. specn: rdso spec.no:rdso/pe/spec/ac/0061 2005(rev 1) or latest.,hermitically sealed scroll compressor suitable for r 407c refrigerant gas,working on 415vac 50hz confirming to rdso spec no rdso/pe/spec/ac/0061 2005(rev 1)or lastest as per model no.zr 61 kce tfd 522 of m/s emerson make. as per drg.no. specn: rdso spec.no:rdso/pe/spec/ac/0061 2005(rev 1) or latest....

Inter-University Centre For Astronomy And Astrophysics - Maharashtra

33015067 supply and installation of air condition supply and installation of air condition , supply, installation, testing and commissioning of hiwall split ac units with all inverter compressor consisting of (1) condensing unit with reputed make hermetically sealed dc twin/swing rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg c. (2) indoor unit consisting of 3/4 row cooling coilblower with motor, filters, drain pan & casing. the evaporator shall be complete with expansion valve & distributor. (3) the minimum acceptable value of coefficient of performance (cop) of the offered split ac model shall be not less than 3.85 for 1.5 tr on 100% (5.0 kw) and and 3.90 for 1.8/2 tr (6 kw) hiwall split ac at rated capacity with 35 deg. c outdoor and 19 deg. c wet bulb conditions. the cop confirmation should be done by the oem on their authentic letter head. (4) the outdoor unit shall be factory tested and filled with first charge of refrigerant r 32/r 410a before delivering at site. (5) necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. the suction lines shall be insulated with closed cell nitrile rubber tube insulation. (7) the units shall be with individual cordless remote. (8)the units shall be suitable for operation on 220/240 volts, 1 ph., 50 hz, 3 wire a.c. supply. 1.8/2 tr capacity (6 kw & above cooling capacity) 5 star, inverter hiwall split ac unit , supply, installation, testing and commissioning of hiwall split ac units with all inverter compressor consisting of (1) condensing unit with reputed make hermetically sealed dc twin/swing rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg c. (2) indoor unit consisting of 3/4 row cooling coilblower with motor, filters, drain pan & casing. the evaporator shall be complete with expansion valve & distributor. (3) the minimum acceptable value of coefficient of performance (cop) of the offered split ac model shall be not less than 3.85 for 1.5 tr on 100% (5.0 kw) and and 3.90 for 1.8/2 tr (6 kw) hiwall split ac at rated capacity with 35 deg. c outdoor and 19 deg. c wet bulb conditions. the cop confirmation should be done by the oem on their authentic letter head. (4) the outdoor unit shall be factory tested and filled with first charge of refrigerant r 32/r 410a before delivering at site. (5) necessary charge of oil and refrigerant gas as required up to handling over & defects liability period of the system. (6) interconnecting piping between evaporator and condensing units as per site requirement insulated suction line & liquid line for all the circuits of one machine. the suction lines shall be insulated with closed cell nitrile rubber tube insulation. (7) the units shall be with individual cordless remote. (8)the units shall be suitable for operation on 220/240 volts, 1 ph., 50 hz, 3 wire a.c. supply.1.5 tr capacity (5 kw cooling capacity) 5 star, inverter hiwall split ac unit , refrigerant copper piping 18/ 20 gauge with 19 mm thick o class insulation 5/8 & 3/8 or 1/2 & 1/4 /suitable for above machines , refrigerant copper piping 18/ 20 gauge with 19 mm thick o class insulation drain piping in hard cpvc with all fittings, supports and clamps upto 50 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe. , refrigerant copper piping 18/ 20 gauge with 19 mm thick o class insulation set of power & control cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. forhiwall split ac. , refrigerant copper piping 18/ 20 gauge with 19 mm thick o class insulation ms structural work and special supporting structure for condensing units, powder coated , refrigerant copper piping 18/ 20 gauge with 19 mm thick o class insulation core cutting in wall/slab for ac piping (pleaser refer tender document for details). => limited...

Reserve Bank Of India - Maharashtra

32965079 1 supply of 2tr split ac supply of high wall mounted, cordless remote, inverter type split air conditioner unit 2 tr capacity, 5 star rated of approved make as per detailed in technical specifications stated in section vii. 2 2 cgst for supply of ac total cgst rate at 14% for item 1 3 3 sgst for supply of ac total sgst rate at 14% for item 1 4 4 installation installation, testing and commissioning of above split air conditioner unit ( sn:1 ) on brick wall with bison board as per detailed in the scope of work as per site condition. 5 5 installation supply and providing fr polyethylene insulated refrigerant gas copper pipes as per manufacturer recommendations. ( excluding 3 mtrs. as stated in item 1 ) . 6 6 installation supply and providing 3c x 2.5 sq. mm. cu. conductor frls as detailed in technical data sheet ( excluding 3 mtrs. as stated in item 1 ) . rates shall also be inclusive of transportation, loading, unloading etc. 7 7 installation supply and providing suitable size hard / soft upvc drain piping along with saddles etc. rates shall also be inclusive of transportation, loading, unloading etc. 8 8 installation supply, installation & fixing of suitable size ms table stand with duly painted with primer of red oxide & final black oil painted using sundry materials etc. 9 9 cgst on installation total cgst on installation charges for items 4 to 8 at 9% 10 10 sgst on installation total sgst on installation charges for items 4 to 8 at 9% 11 11 camc 2tr comprehensive annual maintenance contract charges ( including spares ) for the entire system for each 2 tr & 1.5 tr split ac as per detailed in sn 10, 11 of general condition. these rates will be applicable after expiry of guarantee period and valid for 1st year camc. 2tr 12 12 cgst on camc cgst at 9 % for camc items no.11 13 13 sgst on camc sgst at 9 % for camc items no.11 14 14 buyback 2tr buyback offer for taking away the removed existing split ac, split ac including refrigerant piping as on basis away from the site at bidder cost. 2tr 15 15 cgst for buyback total cgst rate for buyback at 9 % for item 14 16 16 sgst for buyback total sgst rate for buyback at 9 % for item 14...

Ministry Of Coal - Maharashtra

32944859 bids are invited for compressor part no. rd510725op , receiver drier part no. rd511188op , receiver drier part no. rd570621p , pressure switch part no. rd59577op , binary switch part no. rd54640op , expansion valve part no. rd56868op , expansion valve part no. rd570150p , thermostat part no. rd442724p , blower motor 24v part no. rd5504924p , compressor oil part no. rd57103op , evaporator core assembly part no. rd21370op , valve part no. rd58076op , motor 24v part no. rd5512024p , hose 50 ft part no.rd55010600p , hose 50 ft part no. rd55008600p , hose50 ft part no. rd55006600p , 10 female 90 degreepart no. rd57231op , 10 male straight part no.rd56951op , 8 female 90 degree part no. rd56840op ,6 female 90 degree part no. rd56840op , 6 malestraight part no. rd57805op , refrigerant gas partno. r134a , remote mounted condenser part no.r9730 , receiver drier part no. rd594190 total quantity : 282...

Ministry Of Petroleum And Natural Gas - Maharashtra

32881497 bids are invited for refrigerant gas r134a (q3) , empty cylinder r134a gas (q3) , refrigerant gas r404a (q3) , empty gas cylinder r404a (q3) , refrigerant gas 410a (q3) , empty gas cylinder 410a (q3) , refrigerant gas r407c (q3) , empty gas cylinder 407 c (q3) , nitrogen gas (q3) , empty gascylinder for nitrogen gas (q3) , r600a refrigerant (q3) ,empty gas cylinder r600a (q3) , r32 refrigerant (q3) ,empty gas cylinder r32 (q3) , sl 68 compressor oil (q3) ,rl 46 compressor oil (q3) total quantity : 1011...

Western Railway - Maharashtra

32784430 supply of refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder.refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder.,refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder as per specification attached. senior section maharashtra 4.00 set...

Bhabha Atomic Research Centre - Maharashtra

32664952 quotation for fabrication of compressor, assembly, repairing of refrigerant line by brazing, pressure testing, refrigerant gas charging, of water chiller at ebc, kharghar...

Reserve Bank Of India - Maharashtra

32611075 1 supply of 2tr split ac supply of high wall mounted, cordless remote, inverter type split air conditioner unit 2 tr capacity, 5 star rated of approved make as per detailed in technical specifications stated in section vii. 2 2 supply of 1.5 tr split ac supply of high wall mounted, cordless remote, inverter type split air conditioner unit 1.5 tr capacity, 5 star rated of approved make as per detailed in technical specifications stated in section vii. 3 3 cgst for supply of ac total cgst rate at 14% for items 1 and 2 4 4 sgst for supply of ac total sgst rate at 14% for items 1 and 2 5 5 installation installation, testing and commissioning of above split air conditioner unit ( sn 1&2 ) on brick wall with bison board as per detailed in the scope of work as per site condition. 6 6 installation supply and providing fr polyethylene insulated refrigerant gas copper pipes as per manufacturer recommendations. ( excluding 3 mtrs. as stated in item 1 ) . 7 7 installation supply and providing 3c x 2.5 sq. mm. cu. conductor frls as detailed in technical data sheet ( excluding 3 mtrs. as stated in item 1 ) . rates shall also be inclusive of transportation, loading, unloading etc. 8 8 installation supply and providing suitable size hard upvc drain piping along with saddles etc. rates shall also be inclusive of transportation, loading, unloading etc. 9 9 cgst on installation total cgst on installation charges for items 5 to 8 at 9% 10 10 sgst on installation total sgst on installation charges for items 5 to 8 at 9% 11 11 camc 2tr comprehensive annual maintenance contract charges ( including spares ) for the entire system for each 2 tr & 1.5 tr split ac as per detailed in sn 10, 11 of general condition. these rates will be applicable after expiry of guarantee period and valid for 1st year camc. 2tr 12 12 camc 1.5 tr comprehensive annual maintenance contract charges ( including spares ) for the entire system for each 2 tr & 1.5 tr split ac as per detailed in sn 10, 11 of general condition. these rates will be applicable after expiry of guarantee period and valid for 1st year camc. 1.5tr 13 13 cgst on camc cgst at 9 % for camc items no.11 & 12 14 14 sgst on camc sgst at 9 % for camc items no.11 & 12 15 15 buyback 2tr buyback offer for taking away the removed existing split ac, split ac including refrigerant piping as on basis away from the site at bidder cost. 2tr 16 16 buyback 1.5 tr buyback offer for taking away the removed existing split ac, split ac including refrigerant piping as on basis away from the site at bidder cost. 1.5tr 17 17 cgst for buyback total cgst rate for buyback at 9 % for items 15 to 16 18 18 sgst for buyback total sgst rate for buyback at 9 % for items 15 to 16...

Western Railway - Maharashtra

32478584 supply of refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder.refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder.,refrigerant gas r 407c suitable for rmpu of lhb type ac coaches with cylinder as per specification attached. senior section maharashtra 4.00 set...

Central Railway - Maharashtra

32428662 supply of hfc refrigerant gas r 407 chfc refrigerant gas r 407 c,hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each for rmpu of lhb ac coaches. diesel loco shop /pr , maharashtra 180.00 kg...

Central Railway - Maharashtra

32193920 supply of hfc refrigerant gas r 407 c in capacityhfc refrigerant gas r 407 c in capacity,hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each. specn: gas r 407 c,(delivery to be made as and when required by consignee ) dycmm(cwe), matunga , maharashtra 135.00 kg...

Western Railway - Maharashtra

32046824 supply of refrigerant gas r 407crefrigerant gas r 407c,refrigerant gas r 407c suitable for rmpu of lhb type ac coaches....

Tata Memorial Centre - Maharashtra

31977795 supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos. along with required turnkey works. , cat ( a ) supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos along with required turnkey works. , supply, installation, testing and commissioning of linear accelerator ring gantry at actrec, kharghar, maharashtra as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at tmh, mumbai, maharashtraas per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at bbci, guwahati, assam as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at civil hospital, shillong, meghalaya as per tendered technical specifications , turnkey works at actrec , civil modification & interior works , architectural & structural audit & design consultancy: appointment of reputed, govt registered architectural, structural designer having mre than 10 years of experiencedto render interior & structural design consultancy for improvemetn and strucutral rehabilitation work as per aerbs recommendation and interior works matching the existing design, considering the following scope of work. study of available structural audit reports of the referred bunker study of the existing building drawings, structural system and history of repairs visual inspection the bunkers externally and internally tapping exercise with the use of hammer assessment of all structural elements ( slabs, beams, columns, rc walls ) conducting necessary non destructive tests on concrete of existing bunkers ultra sonic pulse velocity 15 nos. points / bunker re bound hammer min 15 nos. points / bunker conducting necessary partial destructive tests on concrete of existing bunkers core cut 1 no. points / bunker preparation separate structural audit reports certifying feasibility of proposedstructural changes at the existing bunker ( aerb drawings ) analysis & design of structural elements for accommodating proposed structural changes at the existing bunker ( aerb drawings ) considering the items mentioned in the boq. preparing ga / schematic structural drawings for proposed revisions getting client’s approval on complete set of ga / schematic drawings sharing design, analysis and ga / schematic drawings to clint appointed structural designer for vetting and incorporating suggested recomendationa and implementing the same before issuing the gfc drawings. preparing working drawings ( structural ) for proposed revisions nominal changes to accommodate in the drawing, if any, as per client’s requirement visiting site to inspect the execution work. total visits 3 nos. issuing stability certificate only after completion of work to our full satisfaction. , preparatory civil , preparation of existing rcc wall or brick wall surface, by scrapping, existing finish / paint cleaning the exposed concrete surface to remove any fungus, loosely particles, scales, by a stiff wire brush, clean by water wash the entire surface, exposed the damaged concrete surface with the help of small chisel and hammer, including collecting, stacking the debris at the site. , carefully removing or chiseling, existing plaster of thickness up to 20 mm from the damaged surface with the help of small chisel and hammer weighing not more than 5 pound, includingcollecting, stacking & carting away the debris from the site wherever required as directed by site incharge , removing existing flooring & skirting tiles, along with backing and bedding mortar, clean the surface, lifting & shifting debris to ground floor & carting away the same out of premises etc. complete. , breaking & removingexisting rcc wall by mechanical cutter without disturbing the adjacent structure, or any other concretemembers including cutting ofreinforcement bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. ( 30 mm thk ) , demolishing the existing brick wall along with plaster bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. , brick wall 230 mm thick , brick wall 115 mm thick , carefully excavating in any kind of soil, in existing building in or out sides, including necessary shoring / propping if required and including carting away the debris including re making the surface in good as same as existing as directed. including dewatering and necessary back filling complete , dismantling of existing wooden / aluminium doors and handing over to the client as directed by pm. , labor charges for shifting the furniture remove all the cupboards and shift the same as directed to facilitate the work. , dismantling existing terrace water proofing including aap membrane, cleaning the roof top free from dust and dirt with mechanical wire brush make it receive new concrete, shifing of debries from terrace to ground and carting away out of actrec campus complete as directed and instructed. , construction civil , leveling and filling of earth below foundation and plinth level with quarry dust mixed with 5% cement ( by volume ) for the depth of 150 mm. after initial fill of 75 mm thick, pour water with required compacting, watering make the sub soil in good condition, pour water to dampen the dry mix enough to cake form. similarly fill second layer of 75 mm. pour water with required compacting after each stage of layer to make the mix damp enough to become solid form , providing and laying p.c.c. m15 ( 1:2:4 ) concrete in foundation as leveling course 150 mm thick including necessary form work, batching, mixing, placing, consolidating etc. complete including wet curing for specified time period. , supplying, providing and placing in position rmc m25 reinforced cement concrete with 20mm downgraded aggregates for walls of accelerator and maze rooms of thickness ranging from 300mm to 600 mm at all levels including vibrating, curing, providing construction joints, leaving cut outs / pockets for placing of inserts / embedment, etc., complete, including cost of providing steel form work with plywood lining for all shapes ( including scaffolding, centering, etc. ) , but excluding the cost of providing reinforcement all as per specifications.include precautions to control heat of hydration and obtaining a homogeneous compact concrete. all exposed concrete surface to be of form finish complete as directed and instructed. , for foundations , for rcc shielding , for terrace shieling , providing and fixing high density ( 7.75gm / cc ) steel plate to the existing concrete surface using holdfast and hot press technique. also, the footing required to carry weight of steel plate would be included as per approved design by the consultant. , supply &fabricating and fixing reinforcement for rcc work with high yield strength ribbed cold twisted tor steel of variousdiametersand all lengths of grade fe 415 / fe 500 conforming to bis specification including cutting, bending, fabricating, welding, wastage and placing in position according to drawings and binding the reinforcement with the use of 16 gauge galvanized binding wire of double fold and providing precast cement cover blocks for main reinforcements to ensure specified cover according to relevant is code.the measurements will be in accordance with is code 1200. , supplying, drilling / cleaning hole and injecting chemical laced heavy duty stainless steel anchor fasteners widely used in strucutral reahabilitation works to support re bars and strenth enough to support additional concrete throug mechnical drilling into exisitng concrete surface. the application to be designed separately for rebars as simply supported, moment or splice connection as per indian or european standard or relevant tested and accepted rebar guidelines. rebars. of 20 mm dia 200 300mm depth. the appointed strucutral designer should submit the detailed design analysis adopted, complete as directed and instructed. , providing and doing brick work with locally available good bricks of class designation 50, in required thickness of walls, in cm 1: 4, including adding polymer admixtureat 500ml per bag of cement, racking the joints, cleaning, carting away the wastages and curing , for 230 mm thick , for 115 mm thick , providign & constructing solid cement concrete block of m 10 grade of required thickness in cm 1:6 with scafolding, labour work at all heights and levels including wastage, scafolding etc omplete as directed and instructed. , providing and doing pressure groiuting with waterproofing compound or structural reapiring compund as per manufacturers specfication as directed by the structral consultant, withinsertion of pvc nozzles with drilling holes at regulaer intervals on exisit g rcc walls, beams, roof slabs etc complete as directed and instructed. ( cosnidered for exsitng rcc walls which are developed cracks. ) , providing & applying plaster at an average thickness of 12 to 15 mm in exact line & level in the proportion of 1 : 4 cement and sand mortar by manual mixing, with addition of waterproofing chemical @ 150 ml and harbourite 12 mm fine fibrillated 100% virgin polypropylene fibers @ 150 gm per bag of cement including curing for at least 7 days, carting away a debris, cleaning ( note: waterproof plaster considered in server room only ) , filling sunken portion of roof with brick bat mixed with cm 1:6 and complete as directed and instructed , providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , miscellaneous civil , providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge. , supplying, providing and laying vitrified tiled floor, wall on cement screed using 600 x 600 mm vitrified tiles. total thickness of screed and tiles to be 30 mm. including lying 125mm high skirting all round. laid area of wall, floor and skirting measured and paid , wall tiling ( 1.8 mtr height ) , floor tiling , providing and fixing floor cover with quick access to sub floor utilities galvanized steel chequer plate for cabling modular factory finished widely for cabel laying to withstand heacy traffic movemetn of heavy matirials thelid has been designed to withstand for heavy loading, all lids are galvanized to prevent corrosion, with the larger lids having substantial underbracing to give the required strength, complete as directed and instructed. , providing and applying pest and rodent control for the required in all respect including guarantee for the 18 months , providing & layi g approved shade minimum 18mm thick granite slab in flooring, window cills etc over cement morter of 1:4 in wastage, labour. complete as directed and instructed. , provide and fixing wall paneling up to the ceiling height in radiation therapy processing room, passage and the control room, using 18 / 12mm thick high quality plywood paneling with 4mm thick veneer finished, cut to shape and size and fixed to wall in straight line including all supports, screws etc complete as per direction of engineer in charge. , p / f trap door in false ceiling with acp panel in shutter and frame fixed ovwr 50x50x2 mm thick aluminumhollow swction with epoxy sealant as per manufacturer specification suspended from ceiling with suitable ms supporting system as per site condition, including p / f 32mm thick insulation on trap door complete as directed and instructed. , painting , providing and applying oil based internal paint as per the manufacturers specification to the interior surface of masonry walls, underside of roof slabs in ups room , control room , passages, of approved colour and shade with minimum two coats of paint. item to include preparing the surface with necessary approved fillers, making good by touch up etc. to give the desired finish , all complete. rate to include cost of the tools, tackles, labour, equipment, etc. ( above wall tiling ) , providing and applying exteriorpaint widly used to mactch exisitng colour schemewaterproofing paint, scrap and clean the surface, applyprimer as base coat, over the primer coat apply two coats or more paint approved color as per manufacturers sepecification all inclusive of labour, scafolding, safety precautions etc complete as directed and instructed. , providing & applyingenamel paint to wooden or steel doors, scrapping, cleaningthe surface, washingandfillingthe crevices with approved paste / putty as filling sealant & applying the paint with one metal primer base coat, two top coats or more over the primer as per manufacturers specification, including, labour, scafolding, safety precaution etc complete as directed nd instruted. , furniture , providing and fixing 5w x 7h, 38 mm thick, double leaf doors in solid hard wood core ( phenyl formaldehyde bonded ) flush shutters both faces commercial ply including ist class c.p.t.w. lippings all around, lock plate and complete hardware, finished with both sides 1.0 mm thk. laminate as per specifications with grooves and clear / frosted glass as per design / detail complete in all aspects with necessary heacy duty hardware fixtures to mactch exisitng hardware fixtures already installed to maintain unifarmity as standerdization as per per the furniture drawing complete as directed and instructed. , repairing and alterations to existing wooden doors, by changing ss hinges, ss fittings and shutters to be 40mm thick, flush type with teak veneers on both sides open type. inclusive of fixing heavy duty automatic door a closure, two doors handles per shutter concealed night latch locking device, etc. complete. , floor mounted storage cupboards within bhabhatron room; to store: accessories. ( location: tomotherapy room passage ) size: 200 cm wide x 250 cm high x 60 cm deep ( 19mm thick commercial grade ply ) , open type cabinetwith shelves with 18 mm thick high quality plywood laminated with 0.9mm thick melamine laminates on both side of approved colour and make with 1 numbers of open type shelves 210cmx200x50cm size with 6 horizontal and 3 vertical partitions inside the therapy room with partitions for immobilization devices, electron applicator and cutouts. type and utility should match with the existing work station. provide necessary drawer 2 nos and shutter 2 nos as per the requirement from the radiation physics division. edges should be finished by machine press. all finishes and quality to be instructed by the engineering in – charge. , providing and supplying officers chair with net back revolving type.the contractor shall furnish one year warranty. economically designed and mat finish. , changing room partition ( 3x4 ) , electrival & lv works , main distribution lt panelsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 1 no 250a tp 25ka mccb + neutral link with built in adjustable o / l, s / c & e / f. mccb with rotary handle mechanism. outgoings : 1no 125a tp mccb with rotory handile machanism for ups, 1no 100a tp mccb with rotory handile machanism for chiller, 1 no. 125 a tpn mccb for hvac & 1 no 63a 25ka tpn mcb with mechanism for hvac unit. busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium .incoming and outgoing cables shall be top of bottom entry only. , ups output panel boardsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 1no 125a tp 25k mccb + neutral link with built in adjustable o / l, s / c & e / f mccb with rotary handle mechanism outgoings : 1nos. 100a 25ka tp mccb with rotary handle mechanism, & 3nos. 40a tpn mcb for db busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium . incoming and outgoing cables shall be top of bottom entry only. , electrical wiring & cabling , distribution boards supply, erection, testing and commissioning the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adaptor box above the db shell also be includeddistribution box 8 way 7segment mcb dbi / c 63 amp fp mcb 1 noo / g 63 amp dp mcb 3 nos o / g 10 / 16a sp mcb 18 nos including all interconnections and other accessories etc as reqd , supply, installation, testing andcommissioning 100a tpn mccb with water proof enclosure including earthing and all other required accessories as per site conditions. for near chiller , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , lt cables supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4r 50sq.mm copper flexible cable truebeam ups incoming & outgoing , 4r 25 sq.mm copper flexible cable for ups input & output and machine , 1c 25 sq.mm copper flexible cable for earth , 4c 16 sq.mm copper flexible cable for chiller , 4c 10 sq.mm copper flexible cable for ac , 4c 6 sq.mm copper flexible cable for db , 12c 0.75sqmm copper flexible cable with pvc conduit for chiller to control panel at console room & warning light , 1c 6sq.mm copper flexible cable for db earthing , cable terminationssupply, erection, testing and commissioning for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4r 50 sq.mm copper flexible cable , 4c 25 sq.mm copper flexible cable , 1c 25 sq.mm copper flexible cable , 4c 16 sq.mm copper flexible cable , 4c 10 sq.mm copper flexible cable , 4c 6 sq.mm copper flexible cable , submain ups and raw power circuits , supply & laying of 2r 2.5sqmm 1r 2.5pvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. , supply & laying of4 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , point wiring supply, installation, testing & commissioning of 3r 1.5sqmm pvc insulated frls copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site. , primary point , secondary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1no13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. ( ups power ) , supply, installation, testing & commissioning of 1no 6 / 16a socket and 1no switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. , installation of light fittings , supply, erection, testing and commissioning of 2 x 2led 36 watts recessed mounting fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed. , supply, erection, testing and commissioning ofled 18 watts recessed mounting down light fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed , supply, erection, testing and commissioning of single3w recessed fixed type led fitting with electronics ballast and all accessories and interconnecting with 3 core 1.5 sqmm pvc insulated frlscopper wire and fixing the same in the ceiling. , data, voice & network , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. , supply, fixing, testing and commissioning of information outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 4u communication rack , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , supply, fixing, testing and commissioning of cat 6 telephone cable . , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , earthing , supply and installation of 4 way earth bus with accessories as required , supply, installation, testing & commissioning of copper earthing with 600x600x3mm copper plate and 25x6mm copper flat bar confirmingis:3043 with the provision for watering & inspection chamber. , perforeated type gi cable tray , supplying, fabricating, erecting and connecting the following 1.6mm thickness gi perforated type cable trays with necessary supports, tees, elbows, bends, bolts and nuts and any other associated accessories to complete the job. 150mm ( wide ) x 50mm ( collar height ) , supply & fixing of 50 mm pvc pipe for cc tv, irm and speaker cable pulling , warning light supplyfixing testing & commissioning of warning light, led green, yellow, red, + power supply . , emergency stop switch supplyfixing testing & commissioning of emergency switch, 3 no. no, element with box , supply fixing & commissioning of lmo switch indicator &buzzer, ss plate with all accessories , supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 10 sq.mm copper flexible cable for ac , 1c 6sq.mm copper flexible cable for db earthing , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , supply testing & commissioning of panasonic make telephone instument with caller id , cctv the camera should be compitable with exisitng cctv system as standerdization, sample must be got approved before supply in bulk. , 16 channel dvr ful hd , hd outdoor bullet camera , hd dome camera , wd hard disk ( dvr ) 1tb , moniter ( 19.5inch ) , camera power supply ( 10amp ) , sdmi cable ( 3 meter ) , bnc conector , dc pin conector , wire 3+1 ( heavy wire ) per / meter , junction box for camera , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1 no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplid. , supply testing commissioning of token display system , firefighting works all devises should be compitable with exisitng system as standerdization, sample must be got approved before supply in bulk. supply, installation, testing & commissioning: , smoke detectors bunker 8 nos; maze 2 nos; ups 2 nos. , response indicator. , manual call bell , hooter , cu. ar. 1.5 sq.mm. cable , fire extinguisher 5kg bunker 4 nos; ups 1 no. , hvac works , supply, installation, testingandcommissioningofaircooledscroll chilling machines having actual capacity of 38.4 tr at chilled water inlet / outlet temperature of 12.0 deg. c / 7 deg. c having evaporator fouling factorof0.000018m2.k / w suitable for operation on refrigerant r 407c or eco friendly gascomprising the following complete as required. chiller capacity should not less than 38.4tr ( followingsafetyfactorwillinbuiltwithchillerunit sppr, under / over load protection, phase reverse protection, hp / lp trip signal interlocking, auto / manual test mode facility / run time equalization for multiple compressor, password access for authorized handling, pt 100 rtd sensor for chiller unit, interlocking for chilled water flow swtich ) 135kw ( 38.4tr ) , air handling units supply, installation, testingandcommissioningoffactorybuiltfloor mounted doubleskintypehorizontal / verticalairhandlingunits made of43+2mm thick panels consisting ofpreplasticizedg.i. casing of thickness 0.8 mm outside layer and 0.8 mm plane gi at inside layer with cfc free p.u. insulation of density 42 ( +5% ) kg / m3 factory injectedbetweenthem byinjectionmouldingmachine, completewith didwbackwardcurvedcentrifugalfanwithvfdstarterdriven, suitablefor50mm wgstaticpressure, coilsectionwithaluminium blue finned copper tubes ( tubes thickness not less than 0.41mm ) cooling coil of 6 row deep, filter section with 50mm thick washable synthetic type air pre filters, belt drive package with tefc drive motor suitable to operate at 415 ± 10% volts, 50hz, 3 phase ac supply, motor should be compatible with vfd, drain connections, stainless steel ( 18g ) drain pan, necessary vibration isolation pads & accessories:and piping as per the norms duly insulated with requires thick nitrile rubber. ahu starterpanelshouldhavevfdandvfdbypassoption, should have plc based control and plc bypass control for manual mode. panel should provide with heater control. note: temp and rh sensor to be included with control wiring. noadditional cost will be given for the same. 30.5 tr 12200cfm 50mm tsp ( 1 working +1 standby motor ) , supply, installation, testing and commissioningof fcu 2 tr , supply, installation, testing and commissioningof primary pump 102usgpm 15m head. , supply, installation, testing and commissioningof expansion tank ( 100 ltr ) with air separator, air vent and pressure maintaining pumping unit. , supply, installation, testing and commissioning of chilled water ms pipe with supports, hardware etc. , 80 mm dia with 32mm nitrile insulation with 26g al cladding , 25 mm dia with 19mm nitrile insulation with 26g al cladding , pvc drain pipe having pressure holding of 8kg / cm2drain piping complete with all accessories with 9mm nitrile rubber insulation with supports , 32mm dia , 25mm dia , supply, installation, testing and commissioningof valves & guages as follows with 32mm nitrile insulation for chw line: , butterfly valve , 80mm dia , 25mm dia , y strainer , 80mmdia , 25mm dia , flexible connection80mmdia , nrv valve80mmdia , 3 way valve , 80mm dia , 25mm dia , ball valve 25mm dia , airvent with ball valve , temperature gauge , pressure gauge , sitc of gi sheet metal rectangular duct with support, hangers, rods, frames, anchor fastners, etc. , 24 gauge , 22 gauge , supplying & erecting accoustic insulation lining on the ducts having 15mm thick open cell nitrile rubber armasound to reduce noise , supplying & erecting thermal insulation on the ducts having 19 mm closed cell nitrile rubber. exposed duct should cover with 26g al cladding , sitc of canvass connection for ahu machines , sitc of control cabling in between for fcu and ahuunits , sitc of fire damper , sitc of fire actuator , sitc of supply / return air grill with vcd , supply, installation and commissioning of duct strip heaters with thyristor control of necessary capacity made of ss strip ( finned / finless tubular type ) complete with rh sensor, industrial grade heating elements, protection against overheating, on / trip status, air flow switch, grounding terminals, terminals for power & control, intermediate control wiring for integration etc. for full automation working to achieve rh level of 40 60% non condensing in the treatment room. ( rating / capacity considered to be specified by the bidder ) , dismantling of existing hvac systems ahu, piping, valves , ducting / copper piping / drain piping / units / hi wall split unit all complete as per instruction as nad directed by oic es , supply and fabrication of ms structure include one coat primer and one coat enamal paint. , dismantling & re installing exisitng ac chiller plant including its roofing at terrace including disconnection of chilled water ms pipe lines, extending same till new location, with required insulation and necessarru hardware as directed and instructructed. , turnkey works at tmh mumbai , civil works : , labour charge only for removing and re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing and refixingavailbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete allonly fixing available door shutter with necessary repairing , removing existing false ceiling of any material and any size with all necessary allied works, removing out debris out of tmh premises , labour charges only for carefully removing and taking out existing wooden partitions ( partly glazed, partly panneled or fully panneled with shutters glazing etc. at all floor levels and locations including removing the existing mongery fittings fixtures locking arrangement and handling over the same to t.m.c all complete as directed , providing wood work with 1st class c.p. teak wood in frames for doors windows, ventilators, air condition frames, clear story window, false ceiling and partitions etc.wrought framed and fixed in position including applying one coat of approved wood primer to the exposed surfaces and tow coats of bitumastic paint to the surface of wood in contact with masonry / concrete etc.complete. in frames of doors, windows, ventilators and clear storey windows etc. fixed with m.s hold fast of size 40x3mmx150mm long bend to shape and embeded in cement concrete 1:2:4. , providing and fixingapproved quality machine pressed phenol formal dehy de bonded commercial / marine ply wood of approved size and fixing the same with necessary nails / screws / adhesive in partition cupboard shelves / ktichen / cabinets / flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick t.w.lipping patti at all exposed edges with nails / screws / hardwares / adhesive wastage in cutting, transportation etc. complete all.commercial ply19mm thick ply , providing and fixing 1.0mm thick laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified. 1.00 mm thick , providing and fixing cabinet made up of 19 mm. commercial ply for top, bottom, sides and shelves and 6mm commercial ply for back side.door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.0mm thick plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in drawing etc.and all exposed edges lipping with 6mm laminate finishthick t.w.lipping patti.locking arrangement withmultipurpose lock etc. all inside areas shall be .80mm thick approved colour laminate etc. with inner side 0.8mm thick laminatewith shutter , providing making and supplying computer table made out fo 19mm commercial ply for table top, mounted on the vertical side fo 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves and shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polishasshown in drawing drawer and wooden key board drawer with heavy sliding channels, withhandle for shutter, cable manager drawers all edges shall be lipped with 6mm thick t.w. lipping patti. all exposed faces should be 1.0mm thick laminate and non laminated area should be french poll shed including cost of other materials labour etc. as per drawing.computer table with all inner surface with 0.8 mm thick laminate , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick made of g i sheet having galvanizing of 100 gms / sqm ( both sides inclusive ) and electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing fixing door frame and shutter side hung to consist of partly glazed partly panneled / fully panneled / fully glazed with 5.5mm thick glass sheet and quality plain or frosted of bajri glass fixed with two way pvc lining / rubber gasket to ensure notes tightness and no rattaling and panneling with 12mm thick nova pan or ancholam finished on both side as required using extruded alumimium section forshutter frame24254545mm satin finish anodized including p / f push pull plates handles and heavy duty fittings like tower bolts, motice lock with keys hinges of 5 inch or 6 inchas per requirement hydraulic door closer / floor spring of suitable capacity etc complete.with powder coated , painting work providing & applying one / two coats of primer two coats of paint as mentioned below first quality paint to the required colour scheme and as per manufacturers instructions / specificationsto the walls, beams, columns, ceilings, partitions, doors etc. including removing existing paints , nails , screws , battens etc. and thoroughly scrapping the surface with sand papers filling up crevices and levelling with putty to obtain smooth surface ie. complete surface preparation etc. complete as directed to the entire satisfaction of engineer in charge. , with two coats of primer and two coats ofpaint , using luster paint , using synthetic enamel paint ( oil paint ) , providing and applying three coats of white wash to ceiling etc. including removing existing nails , screws , battens etc. andthoroughly scrapping the surface with sand papers, filling up the crevices and levelling with putty if necessary adding, required quantity of adhisive to obtain good finish to surface complete as directed. , civil work breaking:dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandur stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including disposing / taking away the debris outside the premises & disposing as per the guidlines of statutory authoritised. ) , granite tiles:providing & laying 8 to 10mm thickgranite tile of size 300mm x 600mmfor flooring / dado / skirting laid over a bedding of c.m. 1:335mm thick in true plain line & level curing. finishing the joints etc. complete.in flooring & in dado / skirting , electricalsworks , point wiring : point wiring for light / fan / bell with isi mark 3 x 1.5 sq.mm ( p+n+e ) . frls pvc insulated copper conductor ofmake in surface / recessed heavy class pvc casing capping / conduit with modular switch ceiling rose / batten holder / slanting holder boxes etc. with circuit labling / marking / ferruling complete. , primary point upto 4 mtrs length , primary point length 4 mtrs to 7 mtrs , primary point length7 mtrs to 10 mtrs , secondary point extending from primary point upto 4 m , dismantling: carrying out assigned jobsof dismantling the existing light, fan, bell, independent plug point wiring of all types with accessories and cable / switchgear , supply & installation of power point ( inclusive of 2no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , supply & installation of power point ( inclusive of 1 no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , telephone point : supplying and instllation of telephone point inclusive of telephone instrument, telephone socket with back box , plate, laying two pair0.5 mm gauge unarmoured telephone wire d.o.t approved, make through conduit / casing caping. , supplying and laying of 2 core audio speaker cable throughconduit / casing caping / cable tray. , sub mainsmains : providing heavy duty pvc casing caping / conduit, supplying and erecting mains with copper conductor pvc insulated frls of 1100 v ac grade wire with circuit labling / marking / ferruling complete. , 2 x 1.5 sq mm + 1.5sqmm earth wire , 2 x 2.5 sq mm + 1.5sqmm earth wire , 2 x 4 sq mm + 2.5 sqmm earth wire , light fixturessupply of led fixtures surface / suspended / recessed mounted luminaires , led light fixture duraslim 15 watt, round6500k, , led light fixture full glow 2ft x 2ft 6500k , distribution boards supply, installation, testing & commissioning dbs , spn db with metal door, 12 way, ip 43, inclusive of required rating mcb, rcbo , tpn db with metal door, 8 way, ip 43, inclusive of required rating mcb, rcbo , hvac works , hvac works ( low side ) fan coils units ( ceiling suspended type / high wall ) supply, installation, testing and commissioning of gi powder coated horizantal ceiling suspended / high wall fan coil units complete with fan, 3 speed motor, 3 row deep cooling coil, 5 mm external static, filters , copper connection, canvass connection ( if required ) , supporting arrangement, electrical wiring etc. the complete fan coil unit shall be in line with the standard specification. the capacity of fan coil units shall be as follows. proper supporting system for fcu to be provided & will be in contractors scope. 800 cfm ( 2 tr ) , hvac works ( low side ) : supply & installation of 2 wayvalve , hvac works ( low side ) : supply & installation of digital thermostat including all accessaries , mountings, wiring between thermostat & unit, terminations etc. , supply, installation testing and commissioning of the following ball valves without strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , supply, installation testing and commissioning of the following ball valves with strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , hvac works ( low side ) :supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class o applied by suiatable adhesive, as per specifications and as required complete in all respect 32mm, insulation work involve removing of old insulation on chilled water pipeline and installing new insulation. , hvac works ( low side ) : providing and fixing in position the following upvc heavy class cut to required length and installed with screw joints including the necessary fittings, supporting arrangements like clamps etc. ( bends, tees, unions, sockets etc ) duly insulated with class o 6 mm thick nitrile rubber insulation as per specifications. 25 mm dia , hvac works ( low side ) supply, installation, balancing and commissioning offabricatedat site gss sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of .63mm thickness complete as required. , hvac works ( low side ) supplying, installing of external thermal insulation on ducts of al faced / closed cell nitrile rubber insulation with anti microbial properties with duct insulation with density 40 55 kg / cum complete as per specifications. •thermal conductivity of insulation material shall not exceed 0.035 w / ( m.k ) & r value as mentioned in ecbc 2008 at mean temperature of 24 degree c as per astm c518. . class o insulation with aluminum foil. • moisture diffusion resistance factor or ‘?’ value of insulation material shall be minimum 7, 000 without any external barrier as per en 13469. • the insulation material shall have fire performance such that it passes class 1 as per bs476 part 7 for surface spread of flame and also passes fire propagation requirement as per bs476 part 6 to meet the class ‘o’ fire category. 25 mm thick. , hvac works ( low side ) supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 300 mm dia , hvac works ( low side ) supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing and commissioning of gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications , dismantling, removing of oldflexible ducting , pipelne, insulation, fcu ( 3nos ) , griil, diffuser etc loading, unloading, lifting shifting, etc and disposing the same outside tmh premises with proper housekeeping complete in all respect , networking supply, installation, testing and commissioning of lan cable room no. hbb b 002 4 nos. of network points, room no. hbb b 003 2 nos. of network points. total networks points. = 6 nos. , turnkey works for site preparation of gmc, shillong , civil shielding works , complete dismantling works inside bunker and console room, of plain cement concrete, flooring, brick work, false ceiling to any depth and width, at all levels below & above ground level of any shape, removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. rate shall include for dismantling of plain cement concrete / brick work by manually / mechanical means with necessary tools and plants, scaffolding, water and power charges, cleaning the surface, preparation of surface etc. rate shall include for stacking the serviceable materials and disposing the unserviceable materials / debris away from the site premises by mechanical means including loading, unloading, clearing the site etc. complete, as directed. ( measurement is done for floor area only ) demolishen of the walls are as per approved drawings , providing and casting in situ cement concrete m 25 ( concrete density 2.35 gms / cc ) of trap / granite / quartzite / gneiss metal for r.c.c. walls as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing complete. ( excluding reinforcement ) . with fully automatic micro processor based plc with scada enabled reversible drum type concrete mixer. with natural sand. for concrete shielding and bunker door wall as per aerb approved drawing , providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the rcc structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 ( 5 parts integral crystalline slurry : 2 parts water ) for vertical surfaces and 3 : 1 ( 3 parts integralcrystalline slurry : 1 part water ) for horizontal surfaces and applyingthe same from negative ( internal ) side with the help of synthetic fiberbrush. for bunker and console area , civil interior & furniture works , 50mm thick cement concrete flooring finished with 3mm thick vinyl flooring location: ups room , 600mmx 600mm vitrified tiles with 100mm matching tile skirting. providing and laying approved quality, colour, design and shade fully homogeneous 600 x 600 mm ( thickness to be specified by the manufacturer ) vitrified tile flooring ( marbonite or granamite, confirming to is code 15622 with water absorption less than 0.08% ) flooring in pattern as detailed in drawing or as directed by the institute and grouted with matching colour approved quality readymade grout, curing, cleaning etc to required line level etc. all complete at all leads, lifts and heights to the entire satisfaction of the institute. providing and fixing 2 3mm thick pop protection over polythene covering sheet to flooring areas till handed over and cleaning, etc all complete as per drawings & specification. ( linac room and console room ) , two coats of plastic emulsion paint over 2 coats of wall putty including primer. location: ( ups room and outside shielding wall ) , providing and laying high quality and density type vitrified wall tile of 1200 mm height in radiation therapy room and the control room, laid on 20mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) or as per the appropriate mortar rquired to hold the wall tiles together, in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge upto false ceiling level. location: ( linac and control console room ) , pest and rodent control from pci location: linac room, control console and ups room , acoustical tile for ceiling with light weight insulating material of high quality supported on grid or finished seamless with support above ceiling. to be finished with white paint or powder coated with white paint, if metallic. the false ceiling panels should be of reputed brands. location: linac room, control console and ups room , constructing cable trenches 300mm wide and 300mm deep as per the drawings , preparing and fixing openable covers of vitrified tiles fixed in the with ability to sustain a load of 200kgs to be placed on the trenches 300 mm wide, all works complete , furniture , revolving chairs height adjustable, medium back with hand rest , skylight , wall mounted storage cupboards within linac room; to store: dosimetry & qa items, linac accessories. ( location: treatment room ) . size: 2m wide x 1.2m high x 0.4m deep ( 19mm thick marine grade ply ) , 40mm thick plywood door with teak wood frame, including all accessories. size 2m x 2.2m , wooden tables for workstations. size: 3 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: console , wooden tables for workstations. size: 4 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: tps , plumbing works , supply & installation and commissioning of chiller inlet & outlet equipment flange & union , supply & installation and commissioning of pressure gauge , supply & installation and commissioning of thermometer , supply & installation and commissioning of auto air vent , supply & installation and commissioning of drain valve , supply & installation and commissioning of chiller water copper piping 15 / 8 18 gauge with insulation 19mm thick , supply & installation of chiller water pipe nylon with wire mesh hss slive flexible 40mm with insulation 13mm thick , supply & installation and commissioning of ball valves 40 mm , supply & installation and commissioning of y strainer 40 mm , supply & refilling of dm water , supply & installation and commissioning of water panel with 2 nos pressure gauge and 5 nos valve, 2 nos thermometer , hvac works , ductable a / c units along with low side works ( up to 50 running meters ) for complete installation & commissioning of ac. supply , installation , testing & commissioning of aircooled ductable split air conditioner with ceiling suspended idu and all standard fitting, gss sheet metal duct ( insulation using resin bounded glass wool with 7 micron aluminium foil ) for air distribution 22 / 24 g, idu ss drain pan as per specification complete with suitable capacity drive motor , aircooled condensor with all accessories , hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, vibration isolator pads, structural support for fixing idu / odu, safety devices including thermal protector, pressure release valve , overload relay single phase preventer etc, power wiring and control cabling ( indoor to outdoor ) , thermostat wiring, high low pressure cut out suitable for 3 phase 440v supply etc complete as required. ( warranty 3 years ) for bunker and console 5.5 tr working and 5.5tr stand by , split units with required copper piping and drainage outlet lines ( for ups room 2tr working and 2tr stand by ) with auto timer switch , 2 litre capacity dehumidifier ( for bunker 2, console 1 ) , electrical works , main lt panel supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 250a 3p mccb with rotary handle mechanism 1no with necessory interlocking arrangement out goings : 100a tpn mccb with rotary mechanism 2 nos. 63a tpn mccb with rotary mechanism 3 nos. 40a tpn mccb with rotary mechanism 1 nos. incoming and outgoing cables shall be of top or bottom entry only. , ups output panel board supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 100a 3p mccb with rotary handle mechanism 1no out goings : 100a tpn mccb with rotary mechanism 1 nos. 40a tpn mccb with rotary mechanism 2 nos. incoming and outgoing cables shall be of top or bottom entry only. , distribution boards supply, erection, testing and commisioining the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adoptor box above the db shell also be included , power & lighting dbs 6 way etpn mcb db, all mcbs shall be of c curve type only meant for lighting application i / c 63 amps fp mcb 1 no o / g 6 / 10 / 16 / 25asp mcb 18 nos including all interconnections. , ups dbs 4 way etpn mcb db, all mcbs shall be of c curve type only meant for ups power application i / c 40amps fp mcb 1 no o / g 10 / 16asp mcb 12 nos including all interconnections. , supply, installation, testing andcommissioning 100a 4p mcb with water proof enclosure including earthing and all other required accessories as per site conditions.for a / c & chiller , supply, installation, testing andcommissioning 100a mccb with ms enclosure including earthing and all other required accessories as per site conditions. for ups incoming & outgoing , l.t.cables supply, laying, testing and commisioining of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 4 sq.mm cu. ar. cable ups db incoming , 4c 10 sq.mm cu. ar. cable for pdb & hvac input cable , 4c 16 sq.mm cu. ar. cable for chillerinput cable , 4run 25 sq.mm copper flexible cable machine incomming & outgoing wiring , 4run 25 sq.mm copper flexible cable ups incomming & outgoing wiring , 1run 25 sq.mm copper flexible cable for earth cable , 4 core 50sq.mm copper ar. cable for upsin & out going power cable , cable termination supply, erection, testing and commisioining for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4c 4 sq.mm cu. ar. cable , 4c 10 sq.mm cu. ar. cable , 4c 16 sq.mm cu. ar. cable , 4run 25 sq.mm cu. flexi. cable , 1run 25 sq.mm cu. flexi. cable , 4 core 50sq.mm al. ar. cable , submains ups & raw power circuts , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( lighting & raw power circuit mains ) , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( ups circuit ) , supply & laying of 2r 4sqmm 1r 2.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( split a / c / power socket circuit ) , supply & laying of2 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , supply & laying of3 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for lmo switch wiring. , supply & laying of8 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for warning lamp wiring. , supply & laying of12 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for chiller remote panel wiring. , point wiring supply, installation, testing & commisioning of 3r1.5sqmm pvc insulated fr copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site condition , primary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1nos 6a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( raw power ) , supply, installation, testing & commissioning of 1no 6 / 13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( ups power ) , supply, installation, testing & commissioning of 1 no 16a switched socket with moulded frontplate gianodised enclosureand other associated accessories as per the site conditions. ( with indicator ) , installation of light fittings , supply, erection, testing and commisioining of 600mm x 600mm 36w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of 6 x 6 18w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of single12 v, 15w led fitting ( or ) 230v, 60wrecessed fixed type halogen fitting with copper ballast, lamps all accessories and interconnection ( dimmer light ) , supply, erection, testing and commisioining of led strip light , data, voice & network ( consile room & tps room ) , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. ( voice and data cable ) , supply, fixing, testing and commissioning of infermation outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 10 / 100 / 1000 mbps 24port t switch with 24 port patch panel , supply of 1 mtr pach card , earthing , supply & laying of 8 swg bare cu. wire , supply and installation of 12 way earth bus with all accessories as required. , supply, installation, testing & commisioning of 10 feet long 600 x 600 x 3mm copper plate or chemical earth pit for machine and ups netural and body earth , miscellaneous , supply & laying of20mm pvc hose , supply & laying of25mm pvc hose , supply, fixing of 105 x 50 mm cms tray for control room , warning lamp em off switch & lmo switch , supply & fixing of emergency stop switch and system on switch with base box , supply and fixing of magnetic door switch , supply, erection, testing and commisioining of led warning lamp for red, green & yellow . , supply, , erection, testing and commissioning of last man out control unit, last man out switch with indicator, buzzer and external wiring kit ( 1.0 sq.mm cu. wire & pipes ) , fire alarm system , supply, fixing, testing & commissioning of 2 zone conventional fire alarm panel with complete set. , supply, fixing, testing & commissioning of conventionalsmoke detectors with base , supply, erection, testing & commissioning of conventional manual call point. , supply, erection, testing & commissioning of conventional hooter / sounders , supply and laying of 2 core 1.5 sqmm copper armoured cable , carbon di oxide type fire extinguisher of 4.5 kgs. capacity, co2 gas filled in brand new seamless cylinder with powder coated finish, made out of manganese steel, with wheel type valve, discharge nozzle, bend & horn, signages etc. complete, , cc tv , supply, fixing, testing & commissioning of hd ir ccd 1 / 3” color camera. ( doom or bullet modal camera ) , supply, fixing, testing & commissioning of hd mini speed dome ir camera. with 10 to 15x zoom, auto iris lens, rs485 control ptz camera , supply, fixing, testing & commissioning of 4 chenal hd dvr , supply, fixing, testing & commissioning of ptz keyboard with joystick , supply, fixing, testing & commissioning of 24” led tv , supply, fixing, testing & commissioning of 12v dc power supply for camera , supply and laying of 3+1 rg 58 cctv cable , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplied. , turnkey works for site preparation of dr. b. borooah cancer institrute, guwhati , a ) civil works , demolishing rcc work including stacking of steel bars and disposal of unserviceable material as directed for all levels , dismantling and removing the existing door and window frame ( chowkath ) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. ( ii ) area of door / window above 3.00 m2 , demolishing cc floors of various thickness including top layer and base course and disposal of debris as directed for all levels. , providing and laying plain / reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) ( i ) using mixer machine ( a ) in substructure up to plinth level p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , ( b ) in super structure from plinth level up to 1st floor level.p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , providing form work of 12mm thick plywood board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. ( b ) floors etc. above 200mm in thickness. , supplying, fitting and fixing in position reinforcement bars conforming to relevant i.s. code for r.c.c. work / r.b. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20g annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. ( no extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate ) ( upto 1st floor level ) a ) from primary producer ( i ) tmt corrosion resistant steel ( crs ) reiforcement bar , plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete ( shuttering where necessary shall be measured and paid separately ) . ( a ) in prop 1cement: 3 sand :6 coarse aggregate by volume , 20 mm thick cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b ) on fair side ( backing coat 10 mm and finishing coat 10mm thick ) a ) in cement mortar 1:3 , providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile ) / white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. ( cement plastering to be measured and paid separately ) . ( coloured pigment should be in conformity with colour of slab and as approved and directed by the department ) . ( iii ) deluxe quality ( i ) with fix a tile , providing vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tilewhite cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) c ) delux range ii ) of size 1200mmx1600mm and above , providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile / white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) . iv ) of size300mmx900mm and above , supplying fitting and fixing of upvc partition wall 5 mm frosted glass , supplying fitting and fixing of upvc double leaf door 5 mm frosted glass , supplying fitting and fixing of upvc sliding door door 5 mm frosted glass , supplying fitting and fixing of upvcsliding window 5 mm frosted glass , providing wood work in frame ( chowkaths ) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with c.c or brick masonry wall including supplying, fitting and fixing with m.s. hold fast ( 40mmx3mmx250mm ) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with c.c and masonry as directed and specified. ( a ) with sal wood , providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent i.s code including oxidised iron butt hinges ( 100mm x 75mm x 3.5mm ) 6 nos with necessary wood screws. a ) decorative type face panel and block board core. ( iii ) 30 mm thick . , supplying, fitting, fixing and painting where necessary ( one coat primer and two coats of paint ) suspended ceiling which includes g.i. perimeter channels of size 0.55mm thick ( having one flange of 20mm and another flange of 30mm and a web of 27mm ) along with perimeter of ceiling, screw fixed to brick wall / partition with the help of nylon sleeves and screws, at 610mm c / c. then suspending g.i. intermediate channels of size 45mm ( 0.9mm thick with twoequal flanges of15mm each ) from the soffit at 1220mm c / c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with g.i.cleat and steel expansion fasteners. ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c / c. then 12.5mm thick square edge fulltone / sundance / cratone / louvertone / textured. gypboard panels of size 595mmx595mm ( conforming to is:2095 1982 ) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c / c. screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for gypboard complete at all levels as specified and directed. ( for light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary ) . ( glass wool to be measured and paid separately ) . m / f frame work with acoustic type slit gypboard ( louvertone ) tiles ( nrc value 0.72 with 50mm glass wool mat backing ) 12.5mm thick. , providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. , wall painting ( two coats ) with plastic emulsion paint on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. ( a ) .plastic emulsion paint , extra over item no 13.4.7 above for every subsequent coat of wall painting with plastic emulsion paint. ( a ) .plastic emulsion paint , water proofing of chajjas, roof slabs, terraces, sunken slabs, septic tank, oh tank, raft slab in basement, walls etc. ( b ) using polymer based cement mortar. , supplying fitting and fixing of sky view , providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections ( i ) square section ( ii ) rectangular hollow section of specification rsh / shs and ( iii ) m.s. circular hlollow section of grade 210 including purlins, bottom runners and providing m.s. cleat, m.s. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a ) using rhs / shs of grade 310 conforming to relevant i.s. code 4923 : 1997 , providing pre painted galvanized ironsheetroofing ( ppgi ) at all levels including fitting and fixing with self drilling, self tapping screws complete. ( roof trusses, purlins etc. to be measured and paid separately. ) as directed by the departement ( v ) 0.80 mm thick , earth / sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. ( b ) with hill sand obtained by truck carriage loading and unloading, and carriage to the site of work. , providing soling in foundation and under floorwith stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. ( a ) .brick on flat soling. , 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure ( ii ) in superstructure above plinth level up to 1st floor level. ( a ) . in proportion 1:3. ( 1 cement:3 sand ) , supplying, fitting and fixing chain link fencing of 10 s.w.g, g.i. wire 50mm x50mm mesh fitted to m.s angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of g.i wire 10 s.w.g at top, middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to m.s angle iron post in p.c.c base etc. with following. a ) corner and end posts with m.s angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. , supply, installation, fixing of dry chemical powder fire extinguisher confirming to is: 2171 with isi mark and co2 cartridge will be confirming to is: 4947 with isi mark, powder will be confirming to is: 4308 with isi mark ( 5 kg ) , wall panelling with ply and mica pesting , finishingold / new wall with water proofing weathercoat smooth anti fungal premium textured exterior finish ofrequired shadeafter clering and clearing the surfaces etc.including scaffolding complete as directed at alllevels ( two coats ) . , b ) external electrification works , supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor / wall mounting compartmentalize panel board of size 0.95m x 1.30mx 0.40m made of 16 swg1.66 m thick c.r. sheet and40mm x 40mm x 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of red oxide metal primer and 2 coats of enamel paint. the panel board is to be erected in 1 : 3 : 6 pcc foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 400a 4pole mccb or switch fuse unit as incomer and provision for 4nos dp or tpn out going as specified and directed by the deptt. confirming to ip 43 protection comprising of the following electrical items: 1. 40mm x 5mm 4 strip copper bus bar 1.20 m length each i20mm x 3mm 4 strip copper bus bar 0.5m each 4 sets 2. digital 3 phase voltmeter accuracy class 0.5 1 no 3. digital 3 phase ammeter accuracy class 0.5 1 no 4. pilot lamp with integral ckt led 110 230 v ( red, yellow, & blue 3 no 5. voltmeter & ammeter selector switch 2 no 6. 2 a slide fuse unit 3nos ( incoming & outgoing switch gear of reqd. rating will be measured and paid separately ) , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt.. 3 & 1 / 2 core a2xfy 240.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from main distribution panel to machine panel , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 185.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from panel to ups and ups to machine control panel , supply, installation & testing of copper plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. g.i. medium duty watering pipewith g.i. fittings such as socket, tee, elbow, nipple and 50 mmx40 mm g.i. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm c.i. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . note:for machine, chiller and ups. , extra for using salt ( 5 kand charcoal ( 96 kin g.i. / copper plate earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . , supply, fitting & fixing 20 mmx3 mm copper strips drawn on vertically or horizontally on building wall / parapet wall in surface system complete with supply of brassnuts & bolts, screws etc including riveting, soldering and making connection as approved by the deptt. ) with earth electrode copper strips and lightning arrestor etc. as specified and directed by the deptt. , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 400.00 sq.mm.3 & 1 / 2 core armoured u.g. cable , c ) internal electrification works , wiring for circuit wiring with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface / recessedpvcconduit wiring system. with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for door interlock, fault ceiling light, laser, cctv, public adress system, ceiling fan, emergency switch , 2.7.1wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts pvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit note:for 6a and 16a power points , 2.7.2wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduitincluding earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for air conditioner , wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. , sb. 8.28supplying with fitting fixing of 6 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including installation of socket outlet 6 / 16 amps 3 / 5 pin combine shuttered complete , including making necessary connection as per direction of department. , supplying with fitting fixing of 10 / 16 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including and fixing of following moulded pvc boxes for in surface system complete as per direction of department. 8 module surface moulded pvc boxes. , supplying including fitting fixing of following front plate of suitable colour as per direction of department. 8 module , supplying including and fixing of following moulded pvc boxes in surface system complete as per direction of department. 12 module horizontal surface moulded pvc boxes , supplying including fitting fixing of followingfront plate of suitable colour as per direction of department. 12 module , supplying with installation testing and commissioning of hi wall 4 star rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the deptt. ) up to 5 m between the room unit and out door unit as directed by the department. 2 ton capacity r410 , supplying with fitting and fixingvoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 5.0 kva automatic input 120 280 v out put 200 240 v , supplying with fitting and fixing of angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 ton to 2.00 ton window / split type a.c. machine , supplying with fitting and fixing of single phase modular a.c starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. , supplying including fitting fixing of followinga.c. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department [ without regulator ] . premium model1400 mm sweep. , supplying with fitting and fixing of 120 watt electronic modular step speed control 2 module type including making necessary connection as per direction of department. 120 watt electronic modular step speed control2 module type , supplying with fitting and fixing panel mounting open execution 35 / 36ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure ) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35 / 36 ka 415v 50 hz 3p mccb 400a , supplying with fitting and fixing panel mounting open execution 25 ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure of the following capacity complete with making necessary connection as approved by the deptt. as specified and directed by the deptt. 25 ka 415v 50 hz 3p mccb 125a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 100a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 63a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.c series 6 to 32a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.b series 6 to 32a , cc camera , public adress system , view box , supplying with fitting and fixing of 12watt, round led ceiling light with frame , supplying including fitting fixing of followinga.c. exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department. heavy duty 450 mm sweep 900 rpm single phase , d ) furniture works , suppying and installation of coloured tv 22 flat led wall mountingas directed by the department. , supplying fitting and fixing of furniture rack, table, store almirah, revolving chair etc. as required. , a ) computer chair ( 6 nos for control console & 6 nos. for tps room ) , b ) master table for use in computer in control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 10 x 3x2.5 ) ( 1 no for control console & 1 no. for tps room ) , c ) wall mounting manual shelf control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 6x2x16 ) , d ) shelf inside the labunkermade of best quality water proof green ply 18mm thick finishing with sunmika size ( 8 x 6x2 ) , e ) sypplying of decorative & comfortable 3 seater patient waiting chairmust be approved by the department. , cat ( b ) buy back items , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at actrec kharghar , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at tmh mumbai...

Indian Navy - Maharashtra

31657201 procurement of equipment and items for retrieval of refrigerant gas from ac plants and ref plants on board in ranvivir for mrac dept. at naval dockyard mumbai. procurement of equipment and items for retrieval of refrigerant gas from ac plants and ref plants on board in ranvivir for mrac dept. at naval dockyard mumbai. , recovery unit vrr 24l os , ¼” hydraulic hose 225 bar with 7 / 16” unf with ss fittings. , 7 / 16x 8 / 16 unf ss adaptor , ¼” bsp x 7 / 6” unf ss adaptor. , voll valve ¼”, 500 bar. , solid ice bar 1’x3’x4’ , gas sample bottles with head assembly ( 01 ltr ) . , lub oil retrieving hose dia ½” , gas sampling hoses with end fitings ( length – 2m, dia – ¼” ) => limited...