Shipping Corporation Of India Limited - Maharashtra

34136184 procurement of spares fire detection and general alarm saracom [ fdsa0001 ] , 1 central panel, 1 repeater panel, 7 magnetic holder, 63 smoke detector, 3 thermal detector, 4 flame detector, 1 timer, 25 manual call point, 2 gen. alarm push button, 1 i.s barrier box, 1 ex i smoke detector, spare mr901m analogue adr. optical smoke detector, mr901m 001 [ sup0005 ] , mr901m analogue addressable optical smoke detector ( n.w.t ) , dwg. no. mr901m 001 maker : n / a, spare mr901m analogue addr.optical smoke detector, mr901m 011 [ sup0006 ] , spare md901 analogue addressable ror heat detector, md901 001 [ sup0007 ] , spare ms302ex i.s i.r conventional flame detect ms302ex 012 [ sup0009 ] , spare cp530 addressable weatherproof callpoints, cp530 011 [ sup0012 ] , cp530 addressable weatherproof callpoints, pc / each noryl se100 etc...

Directorate Of Purchase And Stores - Maharashtra

34116138 supply pre despatch inspection of optical ( photoelectric ) smoke detector supply of 1. optical ( photoelectric ) smoke detector 2. rate of rise heat detector 3. multi sensor smoke detector 4. wall / surface mount manual call point 5. loop sounders 6. lead acid type rechargeable battery , optical ( photoelectric ) smoke detector model:cap320 make cooper , rate of rise heat detector. model:cah330 make:cooper , multi sensor smoke detector. capt340 , wall / surface mountmanual call point model:cbg370s , loop sounders model: cas381 , f ) battery back up unit valve regulated lead acid type rechargeable battery12 v, 12 ah...

Department Of Skill Development - Maharashtra

33975272 bids are invited for cfr resistor assorted , semiconductor diodes 1n4007 , semiconductor diodes 1n5408 , transistors bc547 and bc548 , transistors bc557 and bc558 , transistors sk100 and sl100 , fet bfw10 , mosfet irf540 , ujt 2n2646 , scr tyn604 , diac db3 , triac bt136 , smoke detector kit , dancing led kit , water level indicator kit , sanitizer despenser project kit small , ic 555 ic741 , crocodile clips 50mm red and black , soldering wire 60 40 22 swg khosla make 500 gm reel , hook up wire single strand 25 gauge red and black , 1.0 sq mm multistrand wire polycab red and black , soldering gun 230v 25w solderon make , mcb 10a anchor make , smd resistors 10 different values by 10 each , smd capacitors 10 different values by 10 each , smd transistors 10 different values by 10 each , smd diode, rectifier 05 different types x 10 each , digital multimeter small , digital multimeter make meco model 153b , bnc to bnc cable 1.5 meter length , bnc to crocodile cable 1.5 meter length , cro probes kit 100mhz , power cords three pin 1.5 meter length for computer , vga cable for computer 1.5 meter , wire stripper multitec make , digital lcr meter make htc model 4070 , neon tester make taparia , copmuter keyboard make dell model kb216 , copmuter mouse make dell model ms116 , wifi adapter for pc make tp link model tl wn725n , external ssd for computer make seagate model stlh500400 500 gb , rj 45 connectors , pen drive 64 gb , power cable for pc , 9 volt battery , lan tester , crimping tool , ic 7414 ic 7404 ic 7409 ic 7476 , foam sheets boand 2 feet by 2 feet , pencil colour 48 colour , pencil h , pencil hb , pencil b , eraser big size , transprant cello tape 10 mm , tinted sheet one colour red , t square scale 800 mm 32 inch total quantity : 1737...

Indian Coast Guard - Maharashtra

33726742 procurement of integrated bridge system spares for cgsd ( mbi ) ard 21 , optical smoke detector head, exi, ip44d sv , multi sensor smoke / heat ip44d sv...

Western Railway - Maharashtra

33701086 supply of description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches.description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches.,description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches....

Bharat Sanchar Nigam Limited - Maharashtra

33635540 tender for comprehensive maintenance contract of (7+1) x15tr precision package ac units (m/s emerson make) for phase v impcs mobile billing equipment at 7th floor, mhs bhavan pune 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuitbreaker/sf6 5 transformer (oil filled / dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 high precision air conditioners (hpac units)...

Dhule Municipal Corporation - Maharashtra

33392211 installation of maharashtra fire safety campaign ( district level 2021 22 ) hydrant system, smoke detector, fire alarm, fire extinguisher etc. in the new administrative building of dhule municipal corporation for fire department....

Department Of Technical Education - Maharashtra

33280997 bids are invited for essential electronics equipment male to female jumper wires, male to male jumper wires 1*40 , female to female jumper wires, servo sg90, 16 *2 lcd with green backlight, berg strip male 15 mm 1*40 stip, hc 05 wireless bluetooth module arduino nano usb cabal 30 cm, 9 volt battery cap, 100 rpm 12v dc helical geared motor, bread board, arduino mega 2560 with usb cable, solder lead 1 kg, pir motion detector sensor module hc sr 501, 18mm plastic slide lock sanp cutter, sound sensor, sim 900a gsm modem module with sma antenna, rcs 22 rfid kit, mq 3 alcohol gas sensor module , soil moisture sensor module 5v, smoke detector sensor system with alarm, ds 18b 20 water proof temperature sensor probe, 12v dc motor driver shield for arduino , neo 6mm gps module, rfb led , 12v 1.3 ah lead acid battery charger , finger print sensor module, rain detector sensor ( q3 ) total quantity : 1...

Western Railway - Maharashtra

33072059 supply of description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches.description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches.,description of item: supply of heat cum smoke detector as per technical spec. mentioned below. operating voltage:9 33v,dc stand by current: 50 ua. start up time: 60sec, start up current: 170 ua. alarm current: 90ma(max) thermal rating: 59c(138f), rate of raise of temperature: 11.1c/min(20f/min), smoke sensitivity:(1.9 + 0.76)%/ft, operating temperature: 100c to 37.80c, storage temperature: 100c to 600c, humidity: 0 95%rh, non considering cycle time: 5sec. make: ravel or system sensor only. note: the subject item should be compatible with fire suppression used in ir coaches....

Western Railway - Maharashtra

33072045 supply of smoke detector unit confirming to rcf spec no. edts 087, rev. b, corr. 1 or latest suitable for lhb eog coaches. the material should be procured from icf/rcf /mcf approved sources only.smoke detector unit confirming to rcf spec no. edts 087, rev. b, corr. 1 or latest suitable for lhb eog coaches. the material should be procured from icf/rcf /mcf approved sources only.,smoke detector unit confirming to rcf spec no. edts 087, rev. b, corr. 1 or latest suitable for lhb eog coaches. the material should be procured from icf/rcf /mcf approved sources only....

Airports Authority Of India - Maharashtra

32790277 supply of spares at ats complex, mumbai 4 core armoured copper cable , 4 core armoured aluminium cable, 3 core flexible copper cable, copper conductor frlsh wire , 4 core cable jointing kit , casing and capings, frp junction box , 4 way connector, switch and sockets , , pvc surface box , led emergency light, led lamp., n halogen lamp, emergency exit light, nylon anti bird net , , drill bit set , hallem sheet , fan regulator, fan capacitor, ceiling rose , hbc fuse link, dp rcbo, sp dc series mcb , s digital multifunction meter, digital voltmeter, digital ammeter , led type indication lamp, electrical panel door lock , astro time switch , 4 pole mccb., motor mechanism for operating 4p 630 amp mccb , control contactor, under voltage relay, extended rom , push type actuatorss, load breaker switch , electronic timer, battery for dg set. battery for fire alarm panel , cleaning brush for solar panel smoke detector, copper lugs...

Department Of Civil Aviation - Maharashtra

32778656 bids are invited for 4 core armoured copper cable , 4 core armoured aluminium cable , 3 core flexible copper cable , copper conductor frlsh wire , 4 core cable jointing kit , casing and capings , frp junction box , 4 way connector , switch and sockets , pvc surface box , led emergency light , led lamp , halogen lamp , emergency exit light , nylon anti bird net , drill bit set , hallem sheet , fan regulator , fan capacitor , ceiling rose , hbc fuse link , dp rcbo , sp dc series mcb , digital multifunction meter , digital voltmeter , digitalammeter , led type indication lamp , electrical panel doorlock , astro time switch , 4 pole mccb , motor mechanismfor operating 4p 630 amp mccb , control contactor , undervoltage relay , extended rom , push type actuators , loadbreaker switch , electronic timer , battery for dg set. ,battery for fire alarm panel , cleaning brush for solar panel, smoke detector , copper lugs total quantity : 4516...

Bharat Sanchar Nigam Limited - Maharashtra

32762382 tender for automation of 62.5 kva ea at te bldg. pernem, goa 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuitbreaker/sf6 ) 5 transformer (oil filled / dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer srn item 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 high precision air conditioners (hpac units) i....

Bharat Sanchar Nigam Limited - Maharashtra

32762322 tender for automation of 62.5 kva ea at te bldg. canacona, goa 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuitbreaker/sf6 5 transformer (oil filled / dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer srn item 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 high precision air conditioners (hpac units)...

Central Public Works Department - Maharashtra

32740068 running and maintenance of specialised services of electrical and mechanical equipment like lifts, afas, acs refilling of fire extinguisher etc at main building at aayakar bhavan, mumbai 20, churchgate, mumbai. subhead : refilling of co2 and abc based cylinder in aayakar and providing and fixing the addressable type smoke detector, control module in aayakar bhavan....

Bharat Sanchar Nigam Limited - Maharashtra

32343847 tender for dismantling and shifting of 7.5kva single phase ea set & miscellaneous electronics items from sahakarnagar bts site to bhosari stores. divn.n.i.t. no. : 12 / eee/ bsnl/pn/sd i/2022 23 engine 2. alternator(brushless) 3. battery (lead acid / mntc. free) 4. hv switchgear(vacuum circuitbreaker/sf6 ) 5. transformer (oil filled / dry type) 6. air circuit breaker 7. mccb(ics=icu) 8. sdf units 9. power contactors 10. change over switch 11. intelligent apfc relay 12. bus bar trunking/ sandwiched bus duct 13. power capacitors (mpp/app) 14. digital/ kwhr meter 15. cold shrink ht/lt cable joint 16. rubber matting 17. mcb/ lsolator/elcb/rccb/ distribution board 18. ms/ pvc conduit 19. cable tray 20. ht/lt cables 21. pvc insulated copper conductor wire 22. centrifugal pump 23. submersible pump 24. motors 25. fresh air fans 26. starter 27. single phase preventer 28. gi/ms pipe 29. foot valve 30. gate valve 31. compressors 32. resin bonded glass wool 33. expanded polystyrene 34. gauge 35. controls 36. fine filters 37. gi sheet 38. heat detect 39. ionization detector 40. photo electric smoke detector 41. fire panel(microprocessor based) 42. sprinkler/ hose reel & hose pipe 43. fire extinguisher 44. lift 45. high precision air conditioners (hpac units) ...

Konkan Railway Corporation Limited - Maharashtra

32236519 supply of smoke amp heat detector sensors.smoke amp heat detector sensors., smoke and heat detector sensor ( combo sensors ) system sensor model no 2351 tem smoke detector photo thermal en54 7 2000 en54 5 2000 ( air ) .see d300 04 301 for sanrok make fire suppression system. one set consist of , heat sensors make of sanrok enterprises series 65 heat detector class cs supply 9 33v dc sensitivity 3 percent per m. one set consist of 2 numbers , smoke sensors make of sanrok enterprises optical smoke detec tor series 65 supply 9 33v dc sensitivity 3 percent per m. one set consist of 2 numbers....

Tata Memorial Centre - Maharashtra

32233733 engineering, procurement, supply, installation, testing and commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , cat ( a ) turnkey works required forengineering, procurement, supply, installation, testing & commissioning of cgmp centre of cellular immunotherapies at actrec on turnkey basis , civil work , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 80mm with riser panel arrangement ( including prefilter, damper & riser grill all clean room compliant ) wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin modular wall panels made of 0.8mm thick gi powder coated sheets on both sideswith puf of density 40±2kg / m³as infill, gi profiles for reinforcement along the periphery, floor track suitable to accommodate the epoxy floor flush with wall panel. joint shall be sealed with cleanroom compatible silicon sealant. the thickness of panel shall 50mm with riser panel arrangement wherever required as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. including providing and fixing of pvc conduit 32 mm in the wall panels and factory made cut outs concealed in wall panel for electrical sockets, switch boards, mgs, etc. , supply and installation of double skin totally flush walkable false ceiling made of 0.8mm thick powder coated sheets on both sides withpuf of density 40 ± 2 kg / m³ as infill, gi profiles for reinforcement along the periphery, including ceiling gridfor easy installation and necessary hardware. joints shall be sealed with cleanroom compatible silicon sealant. ( load bearing capacity 150 kg / m2 ) the thickness of panel shall 50mm as per the instruction of engineer in charge and as per approved drawing. the panels should certified for use in clean room facility with 60 minutes fire resistance certification. factory made cut out to be made in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. curvature radius : r 70 type. joint to be sealed with cleanroom compatible sealant. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor.3d internal / external corner coves. joint to be sealed with cleanroom compatible sealant. , providing and fixing flush doors 35mm thick with 1.0 mm laminates on both sides. the item includes teakwood chaukhat ( frame ) made from 75x50 teakwood. the door to have 12mm teak wood lipping on edges. the door is to be complete with cylindrical door lock , 200mm ss / brass handles, tower bolts, 119mm brass / ss hinges, ss door stopper with double rubber stopper and necessary screws etc. all teakwood surfaces to be malamine polished complete to the satisfaction of architect / employer. cost to include all edgings and vision panel of size 250mm*150mm. , supply and installation of extruded aluminium powder coated / anodized clip on type covings for the entire wall to ceiling, wall to wall, wall to floor. coving in epoxy screed for wall to floor. joint to be sealed with cleanroom compatible sealant. , supply and installation of 46 mm thick doors made with pu painted 0.8mm thick gpsp sheets on both sides with puf as infill, 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures. alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , supply and installation of 46 mm thick emergency doors made with fire retardant paint having fire protective certification for 120mintues for door along with suitable infill to resist temperature upto 600 700 degree , alongwith 1.2 mm thick gpsp powder coated door frames, hardware like ss push plate, ss d handle on both sides, ss ball bearing butt hinges, stainless steel push plates on push side. ss 304 ( with engraving ) , double glazed view panel of std.size , dorma ts 71 std.arm door closure for active leaf, concealed flush bolt for double door and provision for automatic bottom drop seal, stainless steel kick plates ss 304 etc. item includes cost of supply and installation of all accessories and fixtures as mentioned above excluding door interlock and door access control and should be clean room compliant fixtures.alongwith provision of toughened vision glass / view panel with 30mm thick border and silicon sealant if required flushed with door and automatic door bottom seal. , demolishing existing brick masonry and tiles with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry / rcc structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of hospital premises and scope also include dismantling and careful removal of doors, distribution panel and storing and stacking complete all as directed by the engineer in charge. ( existing toilets, guard room & record room & ground floor & all areas wherever required for converting ward to cgmp facility ) . the scope also includes cleaning of flooring and scraping, levelling for application of self levelling epoxy coat for flooring. , dismantling of wash basin and removing of wall tiles and all the allied stonework and pipes & fittings wherever necessary and disposal of unserviceable material carting away the debris out of hospital premises or handing over the same to engineer in charge , providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle size 600mm center to center, lock and stopper etc. included in the item rate ) .as approved by engineer incharge. , providing and fixing panic bar / latch ( double point ) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the engineer in charge, all complete. , providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminium sheet having electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing and applying 3mm to 4 mm thick self levelling epoxy flooring system which consist of surface preparation, by grinding the surface , minor repairs if any, applying 1coat of epoxy primer , laying self levelling epoxy screed followed by top coat of self levelling epoxy coat as per manufacturer specification , work inclusive of existing flooring reparing and wall crack filling complete job as directed by eic. , applying 1 2mm thick birla white wall putty followed by final coat of epoxy wall painting wherever required as per the instruction of engineer incharge. , providing and applying and levelling the existing surface with birla white cement based / coloured waterproof putti of average thickness of 2 mm of approved thickness, brand and manufacture, over the plastered wall surface to prepare the surface even and smooth ready for painting purpose etc complete ( rate inclusive of scaffolding matetrial, labour charges ) etc. , providing and applyingacrylic ( premium ) emulsion paint of approvedmakeandshadeonwallswithsand papering& cleaning the surface, applying one coat of primer and lambi / puttytofullsurface3times, thereafterpaintingthe surfaceintwo coatsoverbaseprimercoattoachieveeven finish. rate is inclusive of all double scaffolding, all material and cleaning as per manufactures standard application method & specification etc. complete. , extra cost for projected return air riser panel made of 0.8mm thick powder coated sheets with 150mm projection above the ceiling and flange for fixing duct, with provision for fixing ra grill and filter etc. , gipc perforated grill for return air riser grill of 1.2mm thick with capsulation perforations for return with all necessary fixing arrangements. , supply and installation of 10 micron pre filter for return air riser ( 1000 x 500 mm ) as per the instruction of engineer in charge. , factory made cutout in the ceiling panel forlight fixture & supply & return air grills / hepa boxes in the ceiling panel , providing and fixing of pvc conduit 32 mm in the wall panels , factory made cut outs with concealed in wall panel for electrical sockets, switch boards, mgs, etc. , providing & laying poly vinyl chloride ( pvc ) rolls flooringmanufactured of approved make and approved pattern for flooring, skirting / dadolaid on existing cement tile or concrete of plastered floor finish with suitable adhesive as per manufacturers specifications closejointed and finished to proper bends, slopes and plumbs asdirected etc. complete generally as per manufacturer’s specifications. providing & laying new2mm thck pvc flooring tiles. , toughened lacquered glass panelling: providing and fixing of 6mm thick toughened glass ( premium griha rated lacquered glass from glass manufacturer ) of approved colour by doit&c, mounted on clip ( j / j1 / i type ) or equivalent on a perfectly levelled surface ( granite cladded pedestal ) . lacquered strong glass must be made industrially ( via curtain coating process ) ; opaque ( if viewed against a support wall ) , coated with pu lacquer ( 100 micron thick ) ; colour consistency ( measured by spectrophotometer cm5081 ) ; highly durable ( passes persoz hardness test for minimum 220 oscillations ) ; humid resistant ( conforms to bs en 1036 1999 ) ; environmentally friendly ( no lead, no arsenic, no copper, no formaldehyde ) ; appropriate recycled content ( 12% post industrial / 6% post consumer ) ; compressive strength ( 1000 mpa ) & tensile strength ( 40 mpa ) , same as float glass. tempering should be done as the en 12150. glasses are to be fixed with polymer clips ( single sided j1 & j2 type, double sided i type ) , white backing foam and grey impact absorbing foam; to accommodate upto ± 10mm substrate undulation, and with a horizontal load capacity of 30kg / 100mm and vertical pullout load > 200kg / 100mm, glass should be supported with 1mm thick lip covering upto 3mm of glass surface; clips should be fixed using durable, non corrosive, strong s.s.screw 45mm long. all wooden material to be used shall be anti termite treated. the measurement only for the portion covered by glass to be considered. , granite cladded pedestal made from 200mm thick aac single block masonary including providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut on the blockwork with 1:4 cement mortar on all sides. including resting provision for glass panelling / partition. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge. , dismantling, breaking and cutting of slab by mechanical means i.e by using diamond cutter / sawing machine without causing damage to any beams and columns and lowering the cut pieces of concrete using chain pulley block on the respective lower floor level and handling the cut pieces including cutting it in smaller pieces and stacking / dispose the debris inside the campus as per the instruction of engineer incharge. item includes floor breaking and dismantling. , cutting of tiles and removing mortar for placement of electrical conduits in the floor and then covering the cement grouting flushed at floor level. including all material, labour, machinery required to complete the work as per the instruction of engineer incharge excluding cost of electrical conduits. , structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and painting, including welding, bolting fixing with labour and material all complete. , providing metal roofing sheets manufactured from zinc / aluminum alloy colour coated fromn high tensile steel minimum yield strength 550 mpa; total coated thickness0.60 mm. profile and colour as approved by the architect ; generally as per durashine brand marketed by tata bluescope steel or equivalent including fixing as per manufacturers recommendations and includingflashings and accessories such as ridges, corner flashings, end flashings and galvanised fasteners from reputedmanufacturers such as mark fasteners. for correct levelling and alignment of sheets height of purlin tops shall be adjusted as provided in purlin connections. mode of measurements: plain area in the inclined plane of sheets shall be measured. nothing extra shall be added for collugations, profile, side laps, end laps etc. , supply and installation of double glazed view panels embedded in the clean room wall partitions with flush design fixed with 6mm thick toughened glass and necessary accessories. , window modification as per the instruction of engineer incharge. , dismantling of existing fire fighting system as per the instructoin of engineer incharge , providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building / structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia m.s. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with m.s. tubes, m.s. tube challis, m.s. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. the scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of engineer in charge. note: ( 1 ) the elevational area of the scaffolding shall be measured for payment purpose. ( 2 ) the payment will be made once only for execution of all items for such works. , providing and laying in position ready mixed m15 grade plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of r.m.c. from transit mixer to site of laying and curing, including the cost of centering, scaffolding, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the engineerin charge. ( m15 grade at all locations upto plinth level ) , providing and laying in position ready mixed m 25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of r.m.c. from transit mixer to site of laying, including the cost of centering, scaffolding, shuttering, finishing, including cost of admixturesin recommended proportions as per is : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability and including supply and installation ofpvc water stopper as per direction of the engineer in charge at all levels. , providing and fixing of reinforcement steel including material fabricating, trasporting, loading, unloading, storing on raised steel rack platform, handling, straightening, cutting to length, bending, making hooked ends, hoisting into place at all levels and heights and binding in position ( including providing & using 18 gauge binding wire ) reinforcement bars of all diameters ( is 1786 , fe 500 of all grade ) to shape and size as per approved bar bending schedules and structural drgs. for all kinds of works at all heights & depths as specified including cost of approved quality pvc / concrete cover blocks, spacers, chairs at regular interval as per relevant is code and such other works that are required to make it complete.quantity of steel as per drawing, approved bbs and with authorized overlaps only shall be measured and paid for. quantity for chairs and spacer bars will not be paid. the measurement shall be as per is 1200 and reinforcement hooks and bends shall comply with the requirement of is 2502 unless clearly specified above. , aluminum partition workproviding & fixing alumimium partitionto the requiredheight partly glazed and partly panneledusing anodized aluminium section with satin finish anodizing of required size for bottom, top, middle &vertical rails at required intervals panneling with 12mm thickboth side pre laminatd board fixed with sloping aluminium beeding alround with neoprine gasket glazing with 5.5mm plain glass of approved make fixed withalumimium channel beeding two way pvc lining / rubber gasket to ensure water tightness and including providing necessary cover mould using suitable alumimium section so as to take care of gaps between the walls / ceiling / flooring and partitions etc. including providing and fixing necessary fittings as specified and directed. , aluminum sliding door providing and fixing sliding door to consist of partly glazed and partly panneled with using 5.5mm thick glass sheet of approved make and quality plain glass of approved make fixed with anodized aluminium sloping channel beeding with two way pvc lining / rubber gasket to ensure water tightness and panneling with 12mm thick nosva pan or ancholam board prelamimated board rated on both side as required, guiding rail section, vertical rails section includingproviding pvc guidrails of six 12mmx75mmas required at size concealed type locking arrangement and heavy duty handle set as per requirement including providing & fixing of18mm thick commercial ply with approved laminate of 1.5mm thick and teak wood lipping patti and non laminated surfaces should be polished with approved french polish at requiredshade & colour. , excavation mechanically ( using excavators like jcb / poclain / with bucket ) in all types of soil, including murrum, soft rockfor foundations, wall, columns, plinth beams, basement, raft, ducts, trenches, underground sumps, septic tanks, soak well including shoring and strutting, bailing out water / pumping off water if required, removing and stacking or disposing simultaneously the excavated soilanywhere within the actrec campus and / or spreading soils in layers for site development. all complete as per specification and as directed by the engineer incharge. for depth upto 1.5m. , removal and stacking of paver blocks taking out existing cc interlocking paver blocks from footpath / central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of engineer in charge. , dry stone rubble soling / pitching of 230 250mm size shall be approved quality, hard, free from cracks, durable, preferably black trap. rubble shall be laid on leveled base close to give compact, surface. if base is not properly leveledsame will have to be done without any extra cost. voids in the joints shall be filled with selected chips. a sample of paving shall be prepared and got approved before proceeding ahead. after stones are laid with thickness of 200mm and packed with chips, sandshall be spread and watered to fill remaining voids. sandshall be allowed to go into joints till final packing is obtained. rate quoted shall be for materials, labour, watering, leveling site, before paving, consolidating etc. complete. , providing & fixing soap dispenser metallic bottle. , p&f soap dish holder. , providing & fixing toilet paper holder with flap recessed type ( stainless steel ) . , p&f stainless steel surface mounted sanitary napkin disposal ( with flap ) of approved quality / make. cabinet 18 8, type 304, stainless steel size 270mm ( l ) x 105mm ( w ) x 385mm ( d ) capacity: 4.6 litres equipped with full length stainless steel piano flap , paper towel dispenser. cabinet 18 8, type 304, size 265x90x365 stainless steel finish: stainless steel satin capacity: 450 c fold, 600 multifold , p & f stainless steel hand dryer of approved quality / make. casing:stainless steel # 304 non magnetic, matt finish mounting :wall mounted operation :touch free infra red activation sensor range : 12 cm 15 cm hand dry time :less than 20 secs auto cutoff: 30 seconds motor:brush type, dual ball bearings speed:25, 000 rpm rated power :550 w ( no heating element ) current:2.5 a protection class :ip x 1 blowing volume : > 270 m3 / h air speed:95 m / s ( with speed controller ) , modular cubicle based restrooms of stainless steel make with stainless steel hardware with locking arrangement and 1 spare lock each.handles and hinges to be included in the rate. measurement per cubicle. , p & f 1st quality wvc urinal ( is:2556 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc. complete. cera cat no: s4010101 efs or equivalent , p & f 12mm thick toughened glass urinal partition with all type fitting. ( partition size 300mm x 1050 ) , providing & laying cast in situ rcc m25 grade of concrete. reinforced cement concrete: ( rcc ) reinforced cement concrete of m25 grade using graded stone aggregate of 20mm max. size including consolidation with vibrator & needle of required capacity finishing curing including form work, shuttering and steel reinforcement etc. complete all as directed by the engineer in charge. , a ) . columns ( rmc ) , a ) . lintel & tie beams ( rmc ) , b ) . sunshades ( rmc ) , reinforcement: reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the engineer in charge. ( laps will not be measured ) . with high yield strength deformed bars ( tmt bars ) & ms round bars , providing and fixing of steel shuttering wherever required as per the instruction of engineer incharge , brick work: brick work at all floor level with cement mortar 1:4 using well burnt locally available bricks of approved quality including scaffolding, raking out joints above ground level simultaneous and as directed by engineer in charge. in foundation & plinth drain walls chambers & superstructure of all floor levels , providing & laying of 20mm thk. external wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & laying of 20mm thk. internal wall plastering with ready made plaster of approved make. cement plastering: cement plastering for internal wall and ceiling with cement mortar 1:4 finished smooth with neeru over brick walls of concrete surfaces including hacking the concrete surfaces at all floors and levels in quantities as required at site including scaffolding curing, etc. complete all as directed by engineer in charge. , providing & applying of 2 coats of apex weatherproof paint alongwith one coat of primer to the out side plastered surfaces. , providing & applying of oil bound distemper to theinside plastered surfaces , providing & laying of cc flooring ( 50mm thk ) as per the instruction of engineer incharge. , aluminum openable windows providing & fixing in position aluminium openable window shutter with frame fully glazed / aluminium grills withusing 5.5mm thick glass sheet of approved make and qualityplain / frusted / bajari glass of approved make fixed with aluminium beedingchannels with two way rubber gasket / pvc lining to ensurewater tightness and nos rattling for aluminium grill fixing with fchannel beeding using satin finish anosdized 15 micron jindalsectionsfor shutters and frameof required size and sectionincluding using aluminium / s.s. hinges of required size, tower bolt of required size, c type alum handle for shutterand othernecessary hardware as per requirement etc. complete all asper specified and directed by engineer in charge. the sections should be anodised. , labour charges for alum works : removing the existing partitions / doors and handing over the same at required place anywhere inside the actrec campus as indicated by the engineer in charge. etc. complete. , c.p.v.c. pipes:providing, laying, jointing, fitting, testing heavy quality c.p.v.c. pipes of required dia including all fittings including all brass fixtures such mt and ft required as per site requirement & laying the same at any floor levels including scaffolding all jointing materials & clamping in wooden blocks if required etc. complete as directed & specified by engineer in charge. , 15mm , 20mm , 25mm , 50mm , vetrified dado tiles providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete as per the instruction of engineer incharge. , vetrified floor tiles: providing & laying polished vitrified floor tiles in different ( from 500mm to 800mm ) sizes ( thickness to be specified by manufacturer ) with water resistant less than 0.08% and confirming to is 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) including grouting the joints with white cement and matching pigments etc. complete. , e.w.c.:providing and fixing white vitreous china pedestaltype water closet ( european type w.c. pan ) with seatand lid, level white p.v.c. flushing cistern with capacity as mentioned below, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittingsand fixtures complete including cutting and makinggood the walls and floors wherever required. it should include p or s trap as per approved make with left or right vent in position including fixing it on chair brakcet or wall bracket. with necessary c.p. brass screws & plugs etc.floor mounted ewc universal with 5 to 7 ltrs cistern:special colour as per instruction , pressmatic taps :urinal valve auto closing system with built in control cock with wall flange . providing and fixing including removal of existing if any as per the instruction of eic , granite: providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished ) machine cut for kitchen / toiletplatforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) with joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels of colour black / red / grey etc. , providing and laying water proofing treatment of average 100 mm thick for sunk slabs of toilets and wherever necessary at all the levels with brick / stone aggregates, with layer of 20 mm thickcement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with water proofing compound as specified by the manufacturer, layingbrick bats of required size impregnating in to the base mortar bed with gap of 12 mm all aroundaccording to slope, level and curing the same, the gaps around brick bats filled with cement mortar 1:3 ( 1 part cement : 3 part coarse sand ) mixed with waterproofing compound, 20 30 mm layer above brick bats and finishing top with neat cement @ 2.75 kg / sq.m. screeding and curing etc. in line, level and plumb / slope, complete including furnishing of guarantee for 10 years. ( note : the above rates shall be inclusive of providing and mixing of waterproofing compound as per manufacturers specifications ) , fancy pillar tap: providing & fixing approved make heavy quality c.p.brass screw down pillar tap long nose not less than 810gm. with jam nut easy clean variety of 15 mm n.b. etc. complete all as directed by the engineer in charge , nahani trap: providing & fixing 100mm dia c.i heavy duty nahani trapwith bras c.p. dome type heavy duty s.s. jali all as approved make quality as specified and directed by engineer in charge one way / two way need concrete joints.extra if required , water shower moc ss 304 with all necessary arrangements . , overall size ( 2450 x 2000 x 2000 ) mm. , pass box dynamic dynamic pass box , made out of ss 304 with no 4 finish. should have 600 mm ( h ) , 600mm ( w ) and 600 mm ( l ) internal sizes , supply of ss wall bench bench with ss sink and sensor tap of size 750l x750w x900mmh as per the layout drawing consists of moc: ss 304sheet finish: no4 mat under bench storage module having450x450x180 ss sink sensor one way tap shutters and accessories likesshinges, , ss d handlesetc., pedestal with adjustment set and 25 mm double skin puf infilled top , drain collection tank with weighing scale: , supply of emergency eye wash shower moc ss 304 , electrical work , dg set supply , installation, testing & commisioning of diesel generating ( d.g. ) set with class g3 governing ( 40% step load ) , alternator of 625 kva output at 0.8 pf continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 v, 50c / s, radiator cooled, multi cylinder diesel engine at 1500 rpm , seperately excited amg having class h, spdp alternator ( with battery charging generator ) , with static avr + / 1% & thd<3%, running at 1500 rpm. both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having engine & generator protection ( including ref & rpr ) / parameter display / operator interface / power command 3.3 control system / amf panel / synchronization / dedicated earthing system / rs 485 modbus connectivity, etc. the complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 db at 1 meter, made of 16 / 14 swg crca sheet, complete with first filling of lube oil / diesel / coolant & fuel hoses, battery, 990 liter external fuel tank, residential silencers, mounted on plinth & obtaining necessary approval from electrical inspector. a ) exhaust piping to be raised upto terace level of nearest building. b ) power / control cabling, terminations, etc. c ) 990 ltr. capacity external deisel tank.d ) . height of stack to be maintained as= height of building + 0.2 * vkva . e ) factory testing to be carried out in present of actrec engineering before despatch of equipments. , 625 kva dg set , amf panelsuitable for 625 kva diesel generating set with battery charger and standard accessories. , ms class ‘b’ diesel engine exhaust pipe of suitable size ( including all fittings, clamps, steel support ) of suitable dia for the engine. the pipe shall be provided with 12 mm thick ceramicfibre rope and below to be insulated with cloth and glass wool. , supply & installation of exhaust pipe thermal insulation and cladding. , installation of silencer , supply & installation of silencer thermal insulation and cladding , supply & installation of m.s. supports for exhaust pipe & exhaust structure suitable for 1 x 200 mm exhaust pipe ( structure height 25 mtrs ) including standar panel & tray , supply & installation of s.s. bellows 200 mm with matching flanges, gaskets and fasteners , ups 3 phase in 3 phase out with igbt pwm based rectifier technology with isolation transformer ac input voltage:415 v + / 10% , frequency:50 hz + / 5%, output voltage:415v + / 2% , output frequency:50hz + / 0.5%, efficiency: 0.9. type of battery:smf, battery capacity: for a backup time of as specified, battery charging current:shall be calculate for unity power factor. protection: electronic over voltage trip, electronic under voltage trip, single phase prevention, overload, short circuit and battery overcharge, indications: ac on, inverter on charger fuse, inverter trip. one number rs232 ports to steady the data with all accessories complete etc., , 160kva online ups with isolation transformer 3 phase i / p and 3 phase o / p with 30minutes backup. , sealed maintenance free batteryof 34nos, 12v / 130ah, 30minutes backup. , battery rack with accessories for 160kva ups. , lv panels free standing, floor mounted mcc panel made out of 2mm thick crca sheet duly powder coated after seven tank process consisting of suitable rating incomer, aluminum bus bar supported with dmc / smc barriers & color coded with heat shrinkable sleeves, metering and outgoing feeders ( as mentioned against each panel ) : , mcc panel 1 for ahu 1, 2, 3, 4, 5, 6, 7, 8 ahu for exhaust 2 nos, mcc 2, ups, ldb 1, pdb 1&2 ( as per enclosed sld ) . , mcc panel 02 for air cooled chiller 1, 2 &3 chilled water pump 1, 2, 3, 4, 5, hot water generator 1, hot water generator 2, hot water pump 1, hot water pump 2. ( as per enclosed sld ) , ups panel for eldb 1 , epdb 1 , epdb 2 & epdb 3. ( as per enclosed sld ) , lv ( power & control ) cables 1.1kv grade xlpe / pvc insulated aluminum / copper multi strand conductor steel armoured cables. , 3.5c x300mm² al. armd. xlpe insulated cable. , excavation and cable layoing and backfilling as per the iso norms , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable. , 3.5c x 25mm² al. armd. xlpe insulated cable. , 4 c x 4mm² cu. armd. xlpe insulated cable. , 4 c x 2.5mm² cu. armd. xlpe insulated cable. , 3 c x 6mm² cu. armd. xlpe insulated cable. , 3 c x 4mm² cu. armd. xlpe insulated cable. , 3 c x 2.5mm² cu. armd. xlpe insulated cable. , 1c x35mm² cu. unarmd. xlpe insulated cable. , 1c x70mm² cu. unarmd. xlpe insulated cable. , lv cable end terminations termination of cables with brass double compression glands including cost of crimping lugs / ferrules, solder, cable sockets, insulation tapes etc. , 3.5c x300mm² al. armd. xlpe insulated cable. , 3.5c x240mm² al. armd. xlpe insulated cable. , 3.5c x150mm² al. armd. xlpe insulated cable. , 3.5c x185mm² al. armd. xlpe insulated cable. , 3.5c x 50mm² al. armd. xlpe insulated cable terminations. , 3.5c x 25mm² al. armd. xlpe insulated cable terminations. , 4 c x 4mm² cu. armd. xlpe insulated cable terminations. , 4 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 3 c x 6mm² cu. armd. xlpe insulated cable terminations. , 3 c x 4mm² cu. armd. xlpe insulated cable terminations. , 3 c x 2.5mm² cu. armd. xlpe insulated cable terminations. , 1c x35mm² cu. unarmd. xlpe insulated cable terminations. , 1c x70mm² cu. unarmd. xlpe insulated cable terminations. , earthing supply, installation testing of earthing station as per is standard complete with 600x600x6mm gi plate electrode, salt, charcoal, 2 nos. 50x6 mm aluminum strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm gi strip. , 25x3mm gi strip. , 6mm² single core multi strand wire ( green color ) . , 10mm² single core multi strand wire ( green color ) . , supply, installation testing of earthing station as per is standard complete with 600x600x3mm copper plate electrode, salt, charcoal, 2 nos. 50x6 mm copper strip upto test link, 40 mm dia g.i. watering pipe with funnel, and test link. the chamber size shall be fitted with450 x 450 mm with heavy duty c.i. chamber cover duly painted and marked with pit identification number both inside and outside as per earthing layout drawing. , 50x6mm copper strip. , 25x3mm copper strip. , 2000mmx1000mmx12mm corriguated rubber mats, as per standards. , d.c.p. type fire extinguisher for following capacity cartridge type with gun metal cap 150gram co2 gas cartridge, powder and brackets confirming to is 2171 19885 andcompleted erected with necessary clamps made from 50 x 6mm. ms flat with nut & bolts grouted in wallcomplete. 6kg capacity. , carbon dioxide ( co2 ) fire extinguisher user of following capacity with necessary clamps made from 50 x 6mmm.s. flat with nut & bolts grouted in wall complete. 4.5 kg capacity. , mcb distribution boards : , 12way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 12 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 8way three phase power distribution board with vertical double door type ( vtpn db ) with 125a tpn mccb as a incomer & 8 nos. 32a tpmcb as outgoing circuit. mcb shall be provided with “c” curve. , 1 phase, 8 way lighting distribution board with horizontal double door type40a dp el mcbas a incomer, 6nos. 6 10a sp mcb as a outgoing circuit. mcb shall be provided with “c” curve , 3 phase , 12 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a dp mcb per phase& 30 nos. 16a / 20a sp mcbin outgoing circuit . ( 10 nos, mcb per phase ) ( pdb ) . mcb shall be provided with “c” curve , 3 phase , 8 way distribution boards with horizontal double door type ( etpn db ) with per phase isolation kit , 63a tpn mcb as a incomer, 40 a, 300ma, dp elcb per phase& 18 nos. 16a / 20a sp mcbin outgoing circuit . ( 8 nos, mcb per phase ) ( pdb ) .mcb shall be provided with “c” curve , modular & industrial type switch sockets switch socket industrial type industrial pentra type socket & plug with mcb enclosed in enclosure. the scope includes fixing of enclosures , supply of all fixing accessories / hardware. mcb and socket shall be wired up upto outgoing terminals etc, complete as required. , single phase 25 amp 3 pin socket with straight connected plugwith 25 amp dp mcb. , single phase 32 amp 3 pin socket with straight connected plugwith 32 amp dp mcb. , three phase 32 amp 5 pin socket with straight connected plugwith 32 amp fp mcb. , modular type switch / sockets / lan / telephone system the crca modular box shall be concealed in such way that front plate flush withmodular partition wall and& brick wall front plate shall be ss 304 matt finish. , 16 amp switch 1 nos. with modular box, front & rear plate. , 16 amp switch 2 nos. with modular box front & rear plate. , 16 amp switch 3 nos. with modular box front& rear plate. , 6 / 16 amp switch socket 1 no. with modular box front & rear plate. , 6 / 16 amp switch socket 2 no. with modular box front & rear plate. , rj45 lan socket 1 nos. with modular box front & rear plate. , rj11 lan socket 1 nos. with modular box front & rear plate. , rj45 socketeach 1 nos. with modular box front & rear plate. , cat 6 flexible cable. , 50 pair telephone junction box , 12u rack with 4 nos. 24 port patch panel with all accessaries. , wi fi network point with all accessaries. , 50 pair telephone cable , ip telephone instrument , analogue telephone instrument , supplying and fixing 1 meter length, utp patch cord of cat 6 type in position as per requirement. , supplying and fixing 7 ft length, utp patch cord of cat 6 type in position as per requirement for end point device ( pc / laptop etc ) , sitc of lazr speed 300 fiber, 6 core indoor application, multimode, to be laid through conduit and flexible with all the connectors, couplers, pigtels, lius at both endcrca module box , the crca module box shall be concealed / surface mounted on brick wall / modular partion. , light fixtures , 42w led bottom openable type cleanroom light fixtutre. , 20w led bottom openable type cleanroom light fixtutre. , 39 / 40w led batten type light fixtures. , 1.1 kv, grade frls, pvc insulated multi strand copper flexible cables , 3c x 1.5mm² cu. flexible cable. , 3c x 2.5mm² cu. flexible cable. , 3c x 4mm² cu. flexible cable. , 3c x 6mm² cu. flexible cable. , 5c x 6mm² cu. flexible cable. , 3c x 10mm² cu. flexible cable. , flexible cable terminations including crimping lugs / ferrules etc. complete as required , 3c x 1.5mm² cu. flexible cable terminations. , 3c x 2.5mm² cu. flexible cable terminations. , 3c x 4mm² cu. flexible cable terminations. , 5c x 6mm² cu. flexible cable terminations. , 3c x 10mm² cu. flexible cable terminations. , supply and installation of gi perforated & ladder cable trays : hot dipped galvanized and minimum thickness of hot dip coating is 70 to 100 microns. thickness of cable tray sheet steel for 50 mm to 300 mm cable tray 2.0mm thickminimum height of the perforated cable tray is 30mm or 50mm. cable tray shall be in different widths and shall be in standard length 2500mm long and suitable to couple two cable trays with coupler. support required for fixing the cable trays considered in the structural steel , 50mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 100mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 150mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 300mm ( w ) x 50 mm ( h x 2mm thinkness perforated cable tray. , 450mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , 600mm ( w ) x 50 mm ( h ) x 2mm thinkness perforated cable tray. , structural steel for supports. , pvc conduit with bends, junction boxes, and all necessary accessories and hard ware as following. , 25 mm pvc conduit. , pvc flexible conduit with clamps and all necessary accessories and hard ware as following. , 25 mm flexible conduit. , ceiling fan , 1200mm sweep ceiling fan , bms system software , bms software: graphical user interface software based on ms windows with1000 points & 1 client license .the system should be accessible from anywhere on lanor ethernet . the communication protocol shall be bacnet protocols . system should be scalable in all levels , eggineer and user level passwords. , bms client station:intel i7 3rd generation processor 3ghz, with 1tb x 2nos hard disk, 16 gb ram / dvd rw / keyboard / optical mouse / lan card / 32” led monitor. minimum 4 usb ports. with pre loaded licensed windows 10 professional software ( latest version ) , ms office and anti virus, dual 2gb graphic cards as per tender specification. , server pc: the main servers will be intel xeon processor e5 2600, minimum speed of 2.3 ghz with 6 core, dual gigabit ethernet port, usb port, video port. the server memory will be 16 gb ddr4 ram with 21 inch monitor , laser printer for alarms and reports a4 size ( black & white ) , ddc panels ip based ddc controllers with in built real time clock, 32 bit micro processor cpu, memory, enclosed in ms powder coated enclosureas per io summary , ddc 1&2 ( ahu 1, aeu 1 & ahu 6, aeu 6 ) with io points ofai 26, di 24, ao 10 & do 08 , ddc 3&4 ( ahu 2, 3 & ahu 4, 5 ) with io points of ai 22, di 14, ao 08 & do 04 , ddc 5 for emswith io points of ai 62 , di 0, ao 18 & do 0 , gatewaymodule for integrating the third party systems communicating on one of the standard open protocols such as bacnetand modbus, etc with bms , chiller intigration, energy meters, hot water generator , field instruments testing and commissioning of following instruments with required accessories , dp switch across fan to monitor filter clog status monitoring ( fine filter ) range: max 1000 pa , differential pressure switch for ahu run status range: max 500 pa , duct dp transmitter across fan , room temp, rh & dp display unit with inbuilt dp and external temp & rh transmitter , static pressure senosr for vfd speed , duct mount temperature & rh sensor with temp accuracy: ±2% & rh accuracy: ±3% , damper actuators , room temperature & rh , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 4c x 1 sq mm armoured copper shielded cable , 2c x 1 sq mm armoured copper shielded cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 8 port network switch with rack , validation & documentation : thevalidation to be done after the validation & commisisoning of the facility , validation and commissioning of entire facility including the qualification and operational approach ( protocols for sat and iq and oq, or ioq ) .validation of the bms system with related qualification documents dq / iq / oq / pq as per international norms and client standards. , fire alarm system , addressable2 loop fire alarm control panel ( facp ) with battery charger and with the battery back up for 8 hours normal operation and one hour alarm operation.the facp shall be expandable upto 10 loop. the facp shall include a full featured operator interface control and annunciation panel that shall include a backlit 640 character liquid crystal display, and a qwerty style alphanumeric keypad for the field programming and control of the fire alarm system.system should support upto 159 detectors and 159 modules in one loop. the panel shall be ul listedand fm approved and comply ul 864, 9th edition requirement. the enclosure shall also be ul listed. the quoted rate shall include supply of necessary software and harware for progamming the panel with all necessary licence. ( with fiber support ) , intelligent analog addressable photothermal detector complete with mounting base complete as required. , intelligent analog addressable hest detector complete with mounting base complete as required. , manualcall point with address switch to programme the modules which monitors and reports contact status..complete as required as per technical specification. , addressable horn cum strobe complete as required. , analogue addressable control relay module for ahu tripping and shall bewith the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , should be capable of monitoring shorted loop circuit and automatically restore communications when shorted condi , analogue addressable control module shall be with the facility of hard addressing, capable of providing dpdtcontact rated at 24v dc, 2a.complete as required as per technical specification. , active repeater panel with minimum 640 character backlight lcd display with qwerty keypad and fixed function keys and soft keys. it should have control and display capabilities for all nodes of the network. should have the facility to store 1000 alarm event & 4000 system events. the panel shall be ul listed and fm approved.complete as required as per technical specification. ( with fiber support ) , response indicator , 2c x1.5 mm², pvc insulated frls armoured copper cable for slc loop & power supply, confirming to is standards and specifications..complete as required as per technical specification. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , exit signages , 10a power supply unit , access control system , door access control system access control desktop pc with thefollowingminimumspecifications:intelcorei5, 3ghz, 4gbram, 500gb hdd, 32lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmi output, configurationwithwindows10 pro, office 12 and antivirus , access control system software , time attendance software system as per clients requirement. , access control system will be magnetic door type controlled through card readers and biometrically inncluding all accessories and with necessary cables and terminations. the system will be capable to record the biometric attendance of the authorized personnel and the records will be stored in server. magnetic lock and door sensor , emergency release switch in green polycabonate housing / push to break glass type , proximity cards complete as required , cat 6 cable , ethernet switch 16 channel , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , arrangement of interconnection between fire alarm system and access control system to automatically open the door in case fire emergency. , door interlock system , 2 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable end terminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , 3 door interlocking system with controller unit, in / out ss pb , electromagnetic lock with contact, door position sensor, emergency release switch, control and signal cables, conduits, cables, cable endterminations etc as per the attached technical specification. the controller shall be provided with ethernet communication port. , cctv system , professional grade network video management recorder, comprising 32ch. nvr to record output of all cameras mentioned above with 1920x1080p resolution @30fps, third party ip camera supported, h.264 compression up to5megapixelsresolutionrecording, multipleharddisksloteachhavingmaximumstoragecapacityof24tb, minimum of 30 days recording motion / continuous, 720p @ 25 fps recorded view, and 1920x1080p @30fps live view, 2 usb 2.0 or 3.0, httpnetworkable, backupbyusb / dvdwr, redundant backup of nvr scheme, included software, client licenses and required camera licenses complete as per technical specifications and as required. all the components to be of same make as camera. nvr shall be bis certified. , ip65dome network camera full hd 2 mega pixel low illumination lux 0.5 high sensitivity with 1 / 2 inch progressive image sensor, h.265+ video compression, 1920x1080 @ 20 fps with poe powersupported, onvif s profile, face detection etc, operating temp 10 to +40 degree c, certification bis approved. ( indoor application ) , networktdnirindooroutdoorbulletcamera1by3cmos1, 3mp3point6mmfixed24irledspoe h264, excellent low light performance with 3d noise reduction, saving storage and bandwidth together with h.264 high profile codec , 24portmanagedswitchwith poe / poe+, as required, i / c connections ofl3 switchwith 16port switchx 10 / 100 / 1000t poe ports and 4 x100 / 1000x sfp ports complete etc. as required , rj 45 connectors , closed wall mount rack 12u , led display monitor: the sufficient no. of full hd led monitors with high resolutions screen size of 52” ( diagonal ) are to be provided for viewing all live / recordedcameraproceedings.theresolutionsof1920 ( h ) x1080 ( v ) pixelswithcomfortableviewingangleis proposedforallmonitorssuitableforoperationon220 240vac50hzpowerforthedisplaypanelshouldbe equipped with all standard features such as video in, audio in, hdmi / dvi, rj 45 port etc. , cat 6 utp cable with accessories. , sitc of 3 core*1.5sqmm frls unarmoured power cable with all accessories complete as required. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , p.a. system , six zone voice controller with necessary interface to fire alarm system, and zonal configuration facility complete along with up to 255 pre recorded message, emg evacuation message , high quality 6 watt, 100vspeakers with box ringin ceilingmounted type with tansformer & terminations. , 6w volume control regulator , 250w amplifier , mixing amplifier , table top microphone. , equipment rack for pasystem unit with secure lock & key. , cd player for music source , 0.75sqmm twin twsted wires for speaker on cable tray or pre fixed conduits including terminations. , 25mmsizeofmediumclasspvcconduitalongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , e.m.s. system , standalone controller operator pc: pc with thefollowingminimumspecifications:intelcorei7, 3ghz, 4gbram, 500gb hdd, 32 lcdmonitor, usbmouse, usbkeyboard, dvd / cdwriter, modem / ip connectivity, hdmioutput, configurationwithwindows10 pro, office 12 and antivirus ( work station , operator station , one stand by as per spec ) , ems software , converter for intigration to ems systeam , 16 port ethernet switch with rack , 8 port ethernet switch with rack , smps , field instruments , room dp transmitter with three row display unit ( t&rh and dp ) , room temperature & rh transmitter , control cables, cable trays and conduits with accessories. , 6c x 1 sq mm armoured copper shielded cable , 3c x 1.5 sq mm armoured copper cable , shielded cat 6 cable, 4 pair, utp, 24 awg cable , gi perforated cable tray 50 x 50 x 2 mm with required ms supports , gi perforated cable tray 100 x 50 x 2 mm with required ms supports , gi perforated cable tray 300 x 50 x 2 mm with required ms supports , 25 mm pvc conduit with its mounting accessories , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for electrical items , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , hvac system , air cooled chiller units : supply , installation testing and commissioning of air cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; condenser coils as a mandatory requirement shall have a factory applied anti corrosive protective coating of electro deposited and baked flexible epoxy coating, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprene pad vibration isolators, integralrefrigerant piping and wiring, accessories as required and called for, automatic and safetycontrolsmountedincentralconsolepanelandailmountedonasteelframe.motorshallbesuitablefor 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a or equivalent ) . the noise level for each chiller should not exceed 80 dba at 1 meter, measured at any point from the chiller. inlet temp.of water 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceas permanufacturersdrawing.allms structurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price.microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection. note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. , capacity 60tr ( 2w + 1s ) chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , heat pump 150 kw ( 1w+1s ) , supply, installtion, testing and commissioning of water cooled screw chillers of multiple compressors, machine mounted microprocessor control panel; water cooled condenser, insulated cooler, flow switch at cooler, victaulic coupling at chilled water connection, spring & neoprenepadvibrationisolators, integral refrigerantpipingandwiring, accessoriesasrequiredandcalledfor, automatic and safety controls mounted in central console panel and ail mounted on a steel frame. motor shall be suitable for 415±10% 50cycles. 3 phase ac supply. refrigerant used must be ozone friendly ( r134a / equivalent ) . thenoiselevelforeachchillershouldnot exceed80 dba, measuredat anypoint 1 metersfrom the chiller. hot waterinlettemperatureof450c, outlettemperatureofwater500c.chilledwaterinlettemp.ofwater 12°c, outlet temp, of water 7 °c . rcc foundation as per manufacturer standard has to be included inthepriceasper manufacturersdrawing.allmsstructurerequiredfortheinstallationofchillerisalsoincludedintheprice. flexible expaansion joint / rubber bellow and all the accessories, fitting bolts, nuts and consumables etc as require are included in the price. microprocessorcontrolpanelalongwithchillerloadmanagementoptioninbuilt, tobehookeduptobmsfor parameters monitoring and control. ambient temperature to be considered asfor navi mumbai for chiller selection.note: chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. factory run test: chiller shall be pressure tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested. hot water inlet @ 45 deg c, outlet @ 50.0 deg c.chiller inlet @ 12.0 deg c, outlet @ 7.0 deg c , chilled / hot water pumps supply, installation, testing & commissioning of horizontal / verticle pumps. pump body : cast iron, impeller : stainless steel / aisi 316l. all pumps shall be aligned properly as required as per specifications.minimum efficiency of the pump shall be 75%. the pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply.the motor selected shall be energy efficient having efficiency ( class i ) at full load ranging between 91.5% to 94% in accordance with motor rating as per specification.vendor to check & confirm the motor ratings as specified for outdoor duty application consisting of: a ) pump and motor ( suitable for outdoor and continuous operation ) , b ) mounting frame & vibration isolators, c ) earthing of motor ( ip 55 ) & frame, d ) lifting & mounting of the pumps at locations as shown in drgs. ( at terrace level ) , e ) all accessories require i.e. flexibles, eccentric reducers and expanders, consumables etc., f ) insulation of the pumps and accessories as per the given specifications. , chilled water pumps , capacity:240usgpmhead 35m ( 1w +1s ) for air cooled chiller , capacity:106usgpmhead 35m ( 1w +1s ) for heat pump , hotwater pumps , capacity:180usgpmhead 35m ( 1w +1s ) , electrical panel for pumps for chilled and hot water supply installation and commissioning of electrical panel for pumps including:a ) logic controller with required software, b ) all mcbs, mccbs, vfds, vfd by pass etc as per require, c ) differential pressure sensors / transmitters with control wiring, d ) bms compatibility , electrical panel for pumps , control wiring between dpts and main controller / s , air separator supply , installation , testing and commissioning of 125 mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for chilled water with all assesories. , supply , installation , testing and commissioning of 100mm dia. with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding for hotwater with all assesories. , open type expansion tank supply , installation , testing and commissioning of 1000l ms tank with 50 mm thick polystyreneinsulation with 26 gauge aluminium cladding with make up water connection, over flow and drain provisions for chilled water with all necessary foundation , supply , installation , testing and commissioning of 1000l pvc tank with make up water connection, over flow and drain provisions for hotwater with all necessary foundation. , chilledwater piping: supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 150mm dia. ( 75 mm thick insulation ) , 125mm dia. ( 50mm thick insulation ) , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 65mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 32 mm dia ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , sitc of butterfly valves, required for chilled waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 125 mm ø , 100 mm ø , 80 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 40 mm ø , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , 80 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 100 mm ø , sitc fabricatedchilledwater manifoldfor ahus as below having chw requirement for chw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 100 mm ø , 50 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 80 mm ø , 40 mm ø , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 125 mm ø , 100 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hot water piping supplying, laying / fixing, testing and commissioning of following nominal sizes of hot water piping plumbing inside the building ( with necessary clamps, supports, vibration isolators and fittings but excluding valves, strainers, gauges etc. ) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg / cu.m after a thick coat of cold setting adhesive ( cprx compound ) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip ( as per is:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. note: the pipes of sizes 150mm & below shall be m.s. c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia. , 100mm dia. ( 50mm thick insulation ) , 80mm dia. ( 50mm thick insulation ) , 50mm dia. ( ( 50mm thick insulation ) , 40mm dia. ( 50mm thick insulation ) , 25 mm dia ( 50mm thick insulation ) , valves & instrumentssitc of butterfly valves, required for hot waterpiping including necessary mating flanges, gaskets, bolt & nuts and insulation as mentioned above. , 80 mm ø , 50 mm ø , sitc of ball valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 25 mm ø , sitc of manual balancing valves including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 50 mm ø , sitc of nrvs including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc of y strainers including necessary mating flanges, gaskets, bolt& nuts and insulation as mentioned above. , 80 mm ø , sitc fabricatedhotwater manifoldfor ahus as below having hw requirement for hw pipe size as below comprising of 1 ) 8 rmt of ms erw c class pipe as per is 1239 with all necessary fittings i.e. bends, reducers, flanges etc. 2 ) 5 nos. ball valve / butterfly valve 3 ) 1 no. 2 modulating control valve 3 ) 1 no. balancing valve 4 ) 1 no. y strainerscrewed / flanged end. 5 ) 2 nos. pressure gauges ( 1 in supply line & 1 in return line ) 6 ) 2 nos. temperature gauges with thermowell ( 1 in supply line & 1 in return line ) 7 ) 1 no. auto air vent valve of size 15mm 8 ) 1 no. drain valve of size 25mm 9 ) insulation as mentioned above for the manifold pipe & valve.insulation to be provided complete for fittings ( valves, bends, tees, reducers, flanges etc. ) with gc check cladding above insulation all as per specifications. 10 ) structural steel for supporting manifold. 11 ) reducer + flanges and along with all acessories to installed control valve. , 40 mm ø , 32 mm ø , 25mm ø , supply and installation of condensate drain piping with 19 mm nitrile rubber insulation rigid gi pipes with u trap and fittings. , 25 mm ø , supply and installtion of rubber bellows for pumps in the piping for vibration isolation at the pumpsinlet & outlet connections. , 80 mm ø , gauges, vents & flow switches , water flow switches , auto air vents , pressure gauges 0 7kg / cm2 , temperature gauge 0 500c & 0 1000c , hvac low side items air handling unit recirculation type ahu for classified systems ( iso 7 ) . sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 02 13260 cmh ( 7800 cfm ) with 11tr cooling & 26.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 03 16830 cmh ( 9900 cfm ) with 11tr cooling & 20.0kw heating capacity @ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , ahu 04 10200 cmh ( 6000 cfm ) with 9tr cooling & 12.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panel with internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionmixingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee section filter with flange type filter section with combination of eu 4, eu 5 filtersfilters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie 3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 01 6120 cmh ( 3600 cfm ) with 5.0tr cooling & 7.0kw heating capacity@ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 06 1700 cmh ( 1000 cfm ) with 2.0tr cooling & 3.0kw heating capacity @ 120 sp ( iso 8 ) with 2 motor ( 1 w+1s ) , ahu 07 11900 cmh ( 7000 cfm ) with 9.0tr cooling@ 100 sp with 2 motor ( 1 w+1s ) ( qa qc area ) , once through type ahu sitc of floormountedhorizontaltypeairhandlingunit.sheetmetalsectionalisedcabinettypeahuindoubleskin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.8 mm gi & outer skin 0.8mm precoated giconstruction with 43mm thick puf insulation panelwith internal coving and in thermal break construction, etc. complete with necessary frame work for supporting channels, foundation bolts and completewith followingsectionwithextrudedaluminiumlowleakagetypemanualsupply & returnair damper , fresh air module with extruded aluminium low leakage type manual volume control damper with filter. there will be opening for cable entries for humidity & temp. sensors in mixing chamber section.pre filter, microvee and hepa section filter with flange type filter section with combination of eu 4, eu 5 filters, h 13 ( 0.3? with 99.997% efficiency ) filters at discharge end with galvanised stainless steel ( gss ) frame with section. 2 bend gss / pvc eliminators, chilled water cooling coil section with6 row chilled water coil ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) extruded aluminium low leakage manual by pass damper sandwich type insulated drain pan , drain pan will be 18g ss 304 construction.2rowhot watercoilsection ( 20 gauge cu tubes & 0.2mm thick al fins with hydrophobic coating ) , didw blower section with kruger / greenheck amca certified make blower with antivibration spring isolators, belt driven type , tefc fan motor of efficiency class ie3 or more suitable for 415 volts, 50 hz, 3 phase ip 55 ac supply suitable for vfd application, & mounted on common base frame.pvc canvas connectionat the outlet of the fan. bleed air module with, extruded aluminium low leakage type manual volume control damper.ahu shall be supplied with limit switch, view port, marine lamp and necessory internal control wiring.there will be opening for cable entries for motor in section , unit with magnehelicgauges& necessarytubingacrossthefilter.theairhandlingunitsshouldhavealuminium volume control dampers at supply air outlet.there will be access door across every section of ahu. , ahu 05 13090 cmh ( 7700 cfm ) with 45tr cooling & 41.0kw heating capacity@ 160 sp ( iso 7 ) with 2 motor ( 1 w+1s ) , exhaust unit floor mounted horizontal type exhaust unit. sheet metal sectionalised cabinet type ahu in double skin construction fabricated from thermal break aluminium extruded section frame structure. the inner skin 0.63 mm gi & outer skin 0.63mm precoated giconstruction with 25mm thick puf insulation panel, suitable 20 micron filter, blower and motor, exhaust damper, vibration mounts etc with all necessary hardware. , veu 05 13430 cmh ( 7900 cfm ) @ 75sp motor: ( 1 w+1s ) , chilled water cassette / hi wall unit sitc of chilled water cassette unit withinfrared remote control, micro controller, drain pump & necessary supporting arrangement with ready made valve station complete with butterfly valves / gate valves , 2 way valves with actuators–strainer, pressure cum balancing valves. the entire skid shall be coated with zinc chromate primer coating and then painted with enamel paint.electrical cable connection from mcb / isolatorto cassette unitshall be done by hvac contractor. , 1.0tr ( cabin and passagearea ) , 3.0tr ( office area ) , decorative fcu: chilled water fan coil unit of double skin construction with compact cooling coil, multispeed fan motor, the blower shall be dynamicaly balanced and designed for silent operation, the filters shall be washable synthetic media type arranged for convenient cleaning and replacement, drain pan with pump . the actuator of modulating valve shall be provided with interface cards to receive 0 10v or 4 20 ma signal from minxon digital thermostat. unit complete with all necassary valves.the unit is supplied with corded remote controller of approved as per instruction and as directed by oic es , 2.0tr ( for ups and battery room ) ( 1w+1s ) , 1.0tr ( for storageroom ) , air filtration system hooded type hepa filters supply of hepa filter modules with ss 304 supplyperforated grill in crca powder coated finish side inlet type, with provision for dop, pressure drop measurement along with volume control damper and provision for a flange type hepa filters ( hepa filterh14 type ) including flexible connection. price also include the hepa filter. , size: 610 x 610 x150 mm , size: 450 x 450x150 mm , size: 305 x 305x150 mm , supply, installation, testing & commissioning of 25mm thick thermal insulated aluminium flexible duct of250mm dia duly supported at regular interval as per site requirement etc. complete as required as per specifications. , air distribution and control system ducting supply, fabrication, installation and testing of following sizes of aluminium metal ductingaluminium supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc. the frame shall slide over the duct ends to form flange connection. the flange connection shall be supplied with airtight seals. ducts shall be suitably reinforced using diagonal bends, distance pieces, etc.apermanentnon etching, siliconefreeelasticsealingmaterialshallbeused.exposed duct should have provide al. cladding.duct leak test to carry out after instalttion. , 22 g sheet , 20 g sheet , 18 g sheet , insulation , supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber ( class o ) insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. exposed duct should beprovide with 26 g al cladding. , 32 mm thick on supply air duct , 19 mm thick on return air duct , supply installation of aluminium extruded powder coatedvolume control damper constructed in 18g gi frame and 18g blades complete with handle for main and branch ducts. , al.sq.fourwaytypeairdiffuser ( supply&return ) with18g, g.i. powdercoatedboxwithaluminumcollar damper: , miscellaneousitems , fire damper: supplying, fixing, testing and commissioning of fire dampers in supply air duct / main branch and return air path as and where required of required sizes i / c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. , fire damper , actuator , supply grills , supplying & installtion of perorated type grill for return air riser with 1.2mm thick gipc capsulation perforations with all necessary fixing arrangement. , gi powder coated fresh air louvre with filterand brid screen , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the rooms , room magnehelic gauge ( 50 to 50 pa ) , magnehelicgaugeswithms powder coatedbox andss topcover completewith necessarytubing withprobe to measure the differential pressure acroos the ahus. , on site validation and testing of the complete clean room system:after completion of e&c of all equipment and accessories, validation test shall be conducted as described below: testing & validation as per iso 14644:2001 standards ( velocity, particulate count, temp, humidity, filter, integrity tests to be carried out at the site ) by 3rd party. a comprehensive on site validation and certification service for clean room installation is in the scope. these includes leak detection, clean room level measurement and certification, air flow pattern analysis, dead zone identification and elimination and comprehensive documentation with regard to maintenance & validation procedure. , followingvalidation&testingoftheinstalledclean roomduringfinalcommissioningoftheabovecleanroom project: cleanliness levels as per iso 14644 air quality monitoring particle size efficiencies and quantity count airborne particulate contamination monitoring air velocity measurement & air flow quantity measurement temperature control range tests humidity control range tests filter pressure drop measurements air flow pattern and strength light level checks at 1m working height in clean room room pressurization , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for hvac system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , gas distribution system , supply and installtion of high pressure gas manifold system ( manual ) for four cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , sitc of automatic control panel to transfer co2 between the manifold. , supply and installtion of high pressure gas manifold system ( manual ) for two cylinders for co2 gas with all necessary fitting , hardware etc as per the requirement. ss 304 , 1 / 2 ss 316l tube with necessary fittings and supports ss 316l , 1 / 4 ss 316l tube with necessary fittings and supports ss 316l , 1 / 2 ball valvess 316l , 1 / 4 ball valve ss 316l , sitc of gas control box with gauge regulator, needle valveand all other necessary fillting, hadware etc as per the requirement. , sitc of pvc tube with brass nozzle for providing the connection inside the lab with all necassry hadware, fitting etc as per instruction and as directed by oic es , 1 year warranty is included in the above items. cmc including all spare for the 6 years after warantee period for gas distribution system. , 2nd year cmc after handing over the project , 3rd year cmc after handing over the project , 4th year cmc after handing over the project , 5th year cmc after handing over the project , 6th year cmc after handing over the project , 7th year cmc after handing over the project , cat ( b ) supply, installation, testing and commissioning of following equipment as per tendered specifications of cgmp centre of cellular immunotherapies at actrec , lab refrigerator – 625 ltsas per tendered specifications , clean room lab refrigerator – 625 ltsas per tendered specifications , blood bank refrigerator customized 625 lts as per tendered specifications , automated closed cell processing system as per tendered specifications , cell expansion system as per tendered specifications , mobile processing system ready kart as per tendered specifications , controlled freeze system ( rate controlled freezer ) as per tendered specifications , blood bag centrifuge – 8 bags as per tendered specifications , water bath high precision as per tendered specifications , automated thawer for bags as per tendered specifications , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) as per tendered specifications , air jacketed co2 incubator as per tendered specifications , automated cell counter as per tendered specifications , inverted microscope as per tendered specifications , inverted microscope as per tendered specifications , floor model high speed centrifuge ( bags & vials ) as per tendered specifications , 100 ltr refrigerator as per tendered specifications , sterile connecting device type aas per tendered specifications , sterile connecting device type bas per tendered specifications , hand sealeras per tendered specifications , magnetic based cell separation system cts grade dynamagnet as per tendered specifications , bench top minispin as per tendered specifications , high performance centrifuge for elutriationas per tendered specifications , table top model high speed centrifuge as per tendered specifications , bsl cabinet ( bsl 2* ) as per tendered specifications , ultracentrifuge as per tendered specifications , bench top centrifuge as per tendered specifications , microplate spectrophotometer as per tendered specifications , real time pcr as per tendered specifications , gel dock system as per tendered specifications , end point pcr proflex as per tendered specifications , flow cytometer facs cell sorteranalyzer as per tendered specifications , endotoxin detection system as per tendered specifications , liquid nitrogen tank bags as per tendered specifications , liquid nitrogen tank vials as per tendered specifications , deep freezer 80 cas per tendered specifications , deep freezer 20 to 40 c as per tendered specifications , deep freezer 20 c as per tendered specifications , deep freezer 80 c as per tendered specifications , cryoshipper as per tendered specifications , cat ( c ) cmc after expiry of warranty period for following equipment , lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 1st year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 2nd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 3rd year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 4th year after expiry of warranty period of 2 years , clean room lab refrigerator – 625 lts cmc for 5th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 1st year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 2nd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 3rd year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 4th year after expiry of warranty period of 2 years , blood bank refrigerator customized 625 lts cmc for 5th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 1st year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 2nd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 3rd year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 4th year after expiry of warranty period of 2 years , automated closed cell processing system cmc for 5th year after expiry of warranty period of 2 years , cell expansion system cmc for 1st year after expiry of warranty period of 2 years , cell expansion system cmc for 2nd year after expiry of warranty period of 2 years , cell expansion system cmc for 3rd year after expiry of warranty period of 2 years , cell expansion system cmc for 4th year after expiry of warranty period of 2 years , cell expansion system cmc for 5th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 1st year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 2nd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 3rd year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 4th year after expiry of warranty period of 2 years , mobile processing system ready kart cmc for 5th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 1st year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 2nd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 3rd year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 4th year after expiry of warranty period of 2 years , controlled freeze system ( rate controlled freezer ) cmc for 5th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 1st year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 2nd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 3rd year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 4th year after expiry of warranty period of 2 years , blood bag centrifuge – 8 bags cmc for 5th year after expiry of warranty period of 2 years , water bath high precision cmc for 1st year after expiry of warranty period of 2 years , water bath high precision cmc for 2nd year after expiry of warranty period of 2 years , water bath high precision cmc for 3rd year after expiry of warranty period of 2 years , water bath high precision cmc for 4th year after expiry of warranty period of 2 years , water bath high precision cmc for 5th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 1st year after expiry of warranty period of 2 years , automated thawer for bags cmc for 2nd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 3rd year after expiry of warranty period of 2 years , automated thawer for bags cmc for 4th year after expiry of warranty period of 2 years , automated thawer for bags cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet 6 ft width x 7.5 ft height ( length ) ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 1st year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 2nd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 3rd year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 4th year after expiry of warranty period of 2 years , air jacketed co2 incubator cmc for 5th year after expiry of warranty period of 2 years , automated cell counter – 625 lts cmc for 1st year after expiry of warranty period of 2 years , automated cell counter cmc for 2nd year after expiry of warranty period of 2 years , automated cell counter cmc for 3rd year after expiry of warranty period of 2 years , automated cell counter cmc for 4th year after expiry of warranty period of 2 years , automated cell counter cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type a cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type a cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type a cmc for 5th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 1st year after expiry of warranty period of 2 years , inverted microscope type b cmc for 2nd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 3rd year after expiry of warranty period of 2 years , inverted microscope type b cmc for 4th year after expiry of warranty period of 2 years , inverted microscope type b cmc for 5th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 1st year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 2nd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 3rd year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 4th year after expiry of warranty period of 2 years , floor model high speed centrifuge ( bags & vials ) cmc for 5th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 1st year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 2nd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 3rd year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 4th year after expiry of warranty period of 2 years , 100 ltr refrigerator cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type a cmc for 5th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 1st year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 2nd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 3rd year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 4th year after expiry of warranty period of 2 years , sterile connecting device type b cmc for 5th year after expiry of warranty period of 2 years , hand sealer cmc for 1st year after expiry of warranty period of 2 years , hand sealer cmc for 2nd year after expiry of warranty period of 2 years , hand sealer cmc for 3rd year after expiry of warranty period of 2 years , hand sealer cmc for 4th year after expiry of warranty period of 2 years , hand sealer cmc for 5th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 1st year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 2nd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 3rd year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 4th year after expiry of warranty period of 2 years , magnetic based cell separation system cts grade dynamagnet cmc for 5th year after expiry of warranty period of 2 years , bench top minispin cmc for 1st year after expiry of warranty period of 2 years , bench top minispin cmc for 2nd year after expiry of warranty period of 2 years , bench top minispin cmc for 3rd year after expiry of warranty period of 2 years , bench top minispin cmc for 4th year after expiry of warranty period of 2 years , bench top minispin cmc for 5th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 1st year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 2nd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 3rd year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 4th year after expiry of warranty period of 2 years , high performance centrifuge for elutriation cmc for 5th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 1st year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 2nd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 3rd year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 4th year after expiry of warranty period of 2 years , table top model high speed centrifuge cmc for 5th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 1st year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 2nd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 3rd year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 4th year after expiry of warranty period of 2 years , bsl cabinet ( bsl 2* ) cmc for 5th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 1st year after expiry of warranty period of 2 years , ultracentrifuge cmc for 2nd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 3rd year after expiry of warranty period of 2 years , ultracentrifuge cmc for 4th year after expiry of warranty period of 2 years , ultracentrifuge cmc for 5th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 1st year after expiry of warranty period of 2 years , bench top centrifuge cmc for 2nd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 3rd year after expiry of warranty period of 2 years , bench top centrifuge cmc for 4th year after expiry of warranty period of 2 years , bench top centrifuge cmc for 5th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 1st year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 2nd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 3rd year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 4th year after expiry of warranty period of 2 years , microplate spectrophotometer cmc for 5th year after expiry of warranty period of 2 years , real time pcr cmc for 1st year after expiry of warranty period of 2 years , real time pcr cmc for 2nd year after expiry of warranty period of 2 years , real time pcr cmc for 3rd year after expiry of warranty period of 2 years , real time pcr cmc for 4th year after expiry of warranty period of 2 years , real time pcr cmc for 5th year after expiry of warranty period of 2 years , gel dock system cmc for 1st year after expiry of warranty period of 2 years , gel dock system cmc for 2nd year after expiry of warranty period of 2 years , gel dock system cmc for 3rd year after expiry of warranty period of 2 years , gel dock system cmc for 4th year after expiry of warranty period of 2 years , gel dock system cmc for 5th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 1st year after expiry of warranty period of 2 years , end point pcr proflex cmc for 2nd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 3rd year after expiry of warranty period of 2 years , end point pcr proflex cmc for 4th year after expiry of warranty period of 2 years , end point pcr proflex cmc for 5th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 1st year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 2nd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 3rd year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 4th year after expiry of warranty period of 2 years , flow cytometer facs cell sorteranalyzer cmc for 5th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 1st year after expiry of warranty period of 2 years , endotoxin detection system cmc for 2nd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 3rd year after expiry of warranty period of 2 years , endotoxin detection system cmc for 4th year after expiry of warranty period of 2 years , endotoxin detection system cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank bags cmc for 5th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 1st year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 2nd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 3rd year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 4th year after expiry of warranty period of 2 years , liquid nitrogen tank vials cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 to 40 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 20 c cmc for 5th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 1st year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 2nd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 3rd year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 4th year after expiry of warranty period of 2 years , deep freezer 80 c cmc for 5th year after expiry of warranty period of 2 years , cryoshipper cmc for 1st year after expiry of warranty period of 2 years , cryoshipper cmc for 2nd year after expiry of warranty period of 2 years , cryoshipper cmc for 3rd year after expiry of warranty period of 2 years , cryoshipper cmc for 4th year after expiry of warranty period of 2 years , cryoshipper cmc for 5th year after expiry of warranty period of 2 years...

Directorate Of Purchase And Stores - Maharashtra

32186244 soloa10s smoke detector supply of solo a10s smoke detector test gas canister 250ml non flammable part no. solo a10s001 , supply of solo a10s smoke detector test gas canister 250ml ( non flammable ) part no. solo a10s 001...

Tata Memorial Centre - Maharashtra

32137972 supply, installation, testing and commissioning of mri 3t scan system along with required turnkey works. supply, installation, testing and commissioning of mri 3t scan system along with required turnkey works. , cat (a) supply, installation, testing and commissioning of mri 3t scan system as per tendered specifications at actrec, kharghar, navi mumbai quantity – 1 no. , supply, installation, testing and commissioning of mri 3t scan system as per tendered specifications at actrec kharghar, navi mumbai , cat (b) turnkey works required forinstallation, testing and commissioning of mri 3t scan system at actrec kharghar, navi mumbai , civil work , dismantling existing brick masonary with plaster,tile etc complete including required scaffolding etc complete , removing existing tile flooring and loose material below tiling , removing existing dado tile and loose material , removing existing plaster , removing existing doors,windows and with frame , removing of existing ducts handing over to department , removing of existing light,power pooints,wiring etc handing over to department , carting away debries outside hospital premises to permitted location as per existing norms of dumping. capacity of each truck load will be calculated against each gate bass issued by actrec. , providing and laying6 brick wall in cement mortar 1:6 , providing and laying4 brick wall in cement mortar 1:6 with patly in concrte and stell @ 4feet height , providing and laying factory made precast concrete solid blocks of 100mm/150mm/200mmthickness of grade m10 grade in superstructure above plinth level up to floor v level in cement mortar 1:6 (1 cement : 6 coarse sand) , providing 12mm tk cement plaster in cm 1:6 , providing and applying3 or more coats of plastic emulsion paint on walls as per the manufacturers directions including scaffolding etc. complete. , providing and applying vement based wall putty minimum 2mm thick , wall/floor chasing (upto 200 mm thick concerete ) , trench work as perdrawing cutting down floor finishing with tiles at bottom side and covering with ply and tile on top removable type , supply and laying concrete m20 flooring,lintels,slabs at all heights , reinforcement for reinforced cement concrete at all floors and levels including supplying cutting bending fixing and binding in position with 1.6mm dia soft drawn annealed binding wire including cost of binding wire labour etc. complete all as per specifications and as directed by the engineer in charge. (laps will not be measured). with high yield strength deformed bars (tmt bars) & ms round bars , supply and fixing 35 mm thick flush door panel with 1mm thick laminate both sidewith hinges,aldrop,door closer,door stopper etc complete , 1.5mx2.1m , 1mx2.1m , 0.8mx2.1m , supply and fixing of door frame teak wood 125mm x 100mm size 1st class teak wood with t.w. moulding of 75 x 12mm on wall & frame junction. , 1.5mx2.1m , 1mx2.1m , 0.8mx2.1m , fixing door frame : fixing available wooden frame workfor door/windows of any size by providing m.s. hold fastof size 40mm x 3mm x 150mm long bend to shape andexternal face to be painted by two coats of bitumestic paint. filling the gap with brick work /cement concrete by side finishing plastering and making good the same tc. complete. , removing & re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing & refixing availbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete all as per specified and directed by engineer in charge , supply and fixing sliding window with glass,film,aluminium section, track etc complete , removing of old false ceiling , providing and fixing tiled metal false ceiling of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all tsections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of aluminum sheet having electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. , providing and fixing 2mm thick vinyl floor,with surface preparation ,pasting etc complete , providing and fixing acp wall paneling with aluminium faming ,pasting etc complete , supply & fixing vetrified tile 600mmx600mm flooring & skirtingover sand cement cm 1: 6 bedding. , providing fixing trap door in min 2mm thick acp with aluminum framing supported with necessarry ms struructreetc complete as directed and instructed. , providing & fixing 46mm thick fully flush double skin fire door shutter of 120 minutes fire rating confirming to is:3614(part 11),tested & certified by nabl accredated laboratory door frame & leaf shall be manufactured from 1.6mm (16 gauge) & l.2mm (18guage) minimum thick galvanised steel sheet.the internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. the infill material s~all be resin bonded honeycomb core. the edges should be interlocked with lock seam. all doors shall be finished with polyurethane aliphatic grade paint of approved colour. the door shall have passed minimum 250 hours of salt spray test. , supply and fixing gi chain link 4mmm dia mesh with ms angle frame of 50x50x6mm with flat forchiller enclosure with access ms door complete as directed and instructed with 2 coat of enamel paint over a coat of metal primer. , providing structural steel (mild steel as defined in is 800 2007 clause 2.2)for frame work of the proposed structure including fabricating, cutting, welding, rivetting, bolting, erection and oilpainting with one coat of primer and two finishing coats , providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat ofsteel primer and two coats of enamel paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses : 0.80 mm thick with zinc coating not less than 275 gm/m² . this includes ridges, valleys, long line crimps. , supply and fixing pcc (m25 grade) chiller foundation , design detailing of chiller shade , furniture , providing and placing in position following furniture , 1600mm x 600mm work station tables with 18mm thick plywood one drawer and one storage shelf with fully laminated of approved design and pattern. , 1800mmx600 mm console table 18mm play wood with fully laminated finish. , providing and placing revolving chairs with user adjustable height, medium backrest height, with hand rest manufactured by reputed furniture co which is widely used in and matching exisitng design pattern complete as directed & instructed. , chairs for patient waiting area ms three seater manufactured by repurted co and matching exisitng design patterns complete as directed & instructed. , providing and placing overhead storage with 18mm playwood fully laminate door shutters for storageas per requirement with ms bracket nicely designed & installed below storege units. , providing and placing below counter storage with 18mm playwood & fully laminate door shutters,drawers for storageas per requirement with granite top (1800x750)in mm , providing and placing cupboard with 18mm playwood with fully laminate door shutters for storage of spare parts, accessories and records, as per requirement (1800x900x600) , name boards for all rooms arcylic matching existing design patterns. , dustbins (plastic with lid) , change room locker ms powder coated with stand manufactured by reputed co matching exisitng design pattern complete as directed and instructed. , curtains with aluminnum powder coated track with suspened supports from ceiling for patient changing, complete as directed and instructed. , electrical works , wiring for 5/15 amp poweroutlet with2.5 sqmm 660/1100v pvc insulated, frls, copper conductor wiresin recessed/surface ms conduit including cost of cutting and filling chases supply andfixing of6 pin 16ampsshuttered modular switchsocket, switch plate with internal wiringin g.i. box, earthing of 3rd pin with pvc insulated, green colour 2.5 sqmm copper wire, complete with all accessories as required. (power socket). , one 16a outletonone circuit with switch socket to match existing design patterns. , 5a/15aoutletsonone circuit with two switch sockets to match existing design patterns. , wiring for radiation lamo,emergency stop,push button on off with supply of switches,and lamp , supply and laying 2.5 sqmm light wiring for radiation lamp and radiation lamp , supply and laying 2.5 sqmm light wiring for emmergency stop with emmergency stop supply , supply and laying 2.5 sqmm light wiring for push button on off with push button on off suppy , supply installation testing and commissioning of tpn mcb double door distribution boards dust and vermin protected and rated for 415v.three phase ac supply operation including incoming mccb/mcb/rcbo as per specifications and required capacity neutral bar and earth terminal complete as required and installed in flush with wall including all fixing materials required. mcbs shall conform : 8828 and rcbo/rccb shall conform to is : 12640. , 8 way tpn mcb db with 63a, tpnmcb as incomer 3 nos. 100 a copper bus bars of equal ratings and 24nos. sp mcbas outgoings . , supply, testing & commissioning of factory finished powder coated modular/ compartmentalised panel fabricated out of 14/16 swg ms sheet, dust & vermin proof with minimum ip 52(main panel) degree or protection, voltmeter, meter, indicating lamps, busbars, terminal blocks etc complete as required. as per single line diagram.tpn/spn dbs shall have ip 42 degree of protection, panel/dbs shall have space for 20% addition / deletion of feeders and with incomer 4c of 1c flexible copper conductor of appropriate sizevolt meter ( 0 500v) 1no. ammeter (0 250 amp) 1no. phase indicator lamps .all mccb microprocessor type.busbars 400amp tpn busbar of copper alloy. 400 amp/ 440v tp mccb 1no. mains .200 amp/ 440v tp mccb 1no. to ups . 200amp/ 440v tp mccb with contactor 1no. to ct. 100 amp/440v tp mccb for light and ac100 amp/440v tp mccb for chiller , 3.5 core 150 sqmm aluminum armoured cable with end termination , supply and fixing galvanised cable tray 900mm wide , supply, laying in trenches/on trays/ on racks/ on wall/ structure, testing & commissioning of the pvc insulatedflexible copper conductor power cables of the following sizes complete as required including cable marker and end termination with brass compression gland and copper lugs etc. , 1cx 95 sq mm flexible copper wire and end termination , 1cx 70 sq mm flexible copper wire and end termination , 4cx10 sqmm flexible copper wire for db , 4cx16 sqmm flexible copper wire for chiller , 4 sqmm copper insulated flexible , 2.5 sqmm copper insulated flexible wire , 1.5 sqmm copper insulated flexible wire , wiring for 6a 5/6 pin lightpoint with 1.5 mm2 660/1100v pvc insulated, frls,copper conductor cable in recessed ms conduit including cost of cutting and filling chases as required with fixing of plate, gi box, 6a modular switch shuttered socket and earthing complete with all accessories as required (first point shall be wired from 2.5 mm2660v grade pvc insulated copper wires & looping with 1.5mm2). , supply and fixing mr compatible led lights to match existing design patterns. , providing lights with fitting 600mmx600mm led type 40w to match existing design patterns. , supply and fixing data points rj45 , supply and fixing for telephone points rj45 , supply and laying network cable cat 6 supply fixingconduiting complete , supply and laying telephone cable cat 6 supply fixingconduiting complete , supply and providing network switch 16 port , supply and providing electrical point for split ac6 sqmm cable pahse neutral earthingfrom db up to ac and its switch socket , providing earthing pit copper earthing chemical typewith bore and conductor or conventional type with pit salt,coal , laying earthing conductor from earthpit to ups ,electrical room , two door interlock system with controller, in/out ss pb, em lock, door position sensor, emergency release switch, control and signal cable, etc. , sitc of 2 runs 3.50 x 150 sq mm aluminum armoured cabel from sub station to mri inclduing excavation, back filling dismantling concrete making good surface complete as directed & instructed. , sitc of 400 a tpn mccb with enclosure. , termination of 3.50 x 150 mm for aluminum armoured cable as directed & instructed. , fire fighting system , addressablesmoke detector , conventional hotter with flasher , 2 zone fire alarm panelinbuilt power supply battery charger & battery backup relay interface (common fire) , 2x1.5 sqmm copper cable armoured , response indicator , fire extinguisher 5kg , mr compatible fire extinguisher , hvac work , uninstalled existing hi wall ac including indoor, outdoor units, copper piping, cables etc from reporting room, consultant room console room etc as per instruction and as directed by oic es. , reinstalltion and commissioning of above mentioned units as per instruction and as directed by oic es , all refrigerant piping shall be of copper, complete with supports between indoor & outdoor units duly insulated with 13mm nitrile rubber insulation.rmt indicated is for set of piping between indoor and outdoor machine, individual piping will not be measured. , 1/2,1/4 or equivelant to the units , 5/8,3/8 orequivelant to the units , sitc pvc drain pipe having pressure holding of 6kg/cm2 drain piping complete with all accessories with 6mm nitrile rubber insulation 25 mm dai , sitc control cables between indoor and outdoor unit and to the main supply cables as per instructed and as directed by oic es.all exposed cable should be laid in ladder type tray , central ac , design, supply, fabrication and installation of g.s.s. ducting with volume control dampers on every branch if there is, powder coated supply/return air diffusers with required hardware’s, supports, wooden frame and painting on ducts, ms parts etc with acoustic insulation 19 mm(supply)/13 mm(return)nitrile rubberinsulation as per the smacna standard, approved drawings and instructions of engineer in charge with the following gauges. note: all exposed duct insulation should be with al cladding. , 24 gauge g.s.s. rectangular duct with necessaryinsulation and metallic foil. , dismatling of existing duct with all necessary hardeware as per instruction and as directed by oic es , grills and damper , sitc of extruded aluminium powder coated diffuser/grill with volume control damper with all necessary supports as per directed and as instructed by oic es , sitc of extruded aluminium powder coated diffuser/ grill without volume control damper with all necessary supports as per directed and as instructed by oic es , sitc of dehumidifier with capacity of 50l/day. , mgps works , copper pipes specifications of mgps system medical gases supply system distribution piping copper pipeline.the piped distribution system must use copper pipes manufactured from phosphorus deoxidized non arsenical copper. all pipelines used along with flow meter etc. should be isi mark preferably size, , 12mm & 15 mm and thickness of 0.7 & 0.9mmshould be drawn, seamless, deoxidized, nonarsenical, half hard tempered and degreased materials conforming to bs6017/1981 and manufactured as per bs 2871/the new european standard en 1057.all copper pipes are to be certified by authorized test house services for physical properties and chemical properties.copper to copper joints shall be made on site using a silver copper phosphorus brazing alloy. copper to brass or gun metal joints shall not be made on site.pipe lines should be supported at the intervals specified in htm 2022 using suitable metallic, non ferrous material. plastic supports may be used only for the drown drops to the terminal units.fitting shall be end feed type, manufactured from the same grade of copper on the pipes.fittings shall be degreased suitable for oxygen use and supplied sealed in protective bags , 12mm pipeline , 15mm pipeline for oxygen , high pressure tubing , non magnetic connector , medical gas outlets non magnetic bs standard and duly ce marked. medical gas outlets with probes. , self sealing valve outlet for oxygennon magnetic , self sealing valve outlet for vacuum non magnetic , isolation valve : 15 mm isolation valve with suitable fittings , handle without teflon tape. easy to close and operate , oxygen flow meter with humidifier bottle , it should have humidifying bottle with whole flow meter assembly, should be of light weight material. it should have backpressure compensated flow meter. it should provide accurate gas flow measure by 0 15 liter/m flow meter. flow tube should be of good quality, transparent with measuring humidifying bottle. flow meter should be fitted with matching adaptor (probe) for oxygen outlet point , ward vacuum unit , it should include vacuum pressure regular up to 760 mm hg with dial gauge . should have re usable collection bottle 1000 ml made with a wall bracelet. or unbreakable polycarbonate materials, fully auto clavable along with safety device to prevent overflow and with a wall bracetk. should be wall mounted and back flow resistance should have 600ml capacity with play contracted jar the controller should be operated by means of a 180 degree on/off switch and a bonnet adjustment , cat (b) buy back items , buy back (ie minus)amount of old mri system at actrec kharghar...

Department of Industrial Policy and Promotion - Maharashtra

32114545 bids are invited for control panel , cylinder assembly , agent fk1230 , master kit , discharge nozzle , cylinder bracket , hooter flasher , heat smoke detector , uv flame detector , piping fittings ,warnning signs , manual unit , abort unit , cables , labourinstallation , labour cables total quantity : 392...

Tata Memorial Centre - Maharashtra

31977795 supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos. along with required turnkey works. , cat ( a ) supply, installation, testing and commissioning of linear accelerator ring gantry 5 nos along with required turnkey works. , supply, installation, testing and commissioning of linear accelerator ring gantry at actrec, kharghar, maharashtra as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at tmh, mumbai, maharashtraas per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at bbci, guwahati, assam as per tendered technical specifications , supply, installation, testing and commissioning of linear accelerator ring gantry at civil hospital, shillong, meghalaya as per tendered technical specifications , turnkey works at actrec , civil modification & interior works , architectural & structural audit & design consultancy: appointment of reputed, govt registered architectural, structural designer having mre than 10 years of experiencedto render interior & structural design consultancy for improvemetn and strucutral rehabilitation work as per aerbs recommendation and interior works matching the existing design, considering the following scope of work. study of available structural audit reports of the referred bunker study of the existing building drawings, structural system and history of repairs visual inspection the bunkers externally and internally tapping exercise with the use of hammer assessment of all structural elements ( slabs, beams, columns, rc walls ) conducting necessary non destructive tests on concrete of existing bunkers ultra sonic pulse velocity 15 nos. points / bunker re bound hammer min 15 nos. points / bunker conducting necessary partial destructive tests on concrete of existing bunkers core cut 1 no. points / bunker preparation separate structural audit reports certifying feasibility of proposedstructural changes at the existing bunker ( aerb drawings ) analysis & design of structural elements for accommodating proposed structural changes at the existing bunker ( aerb drawings ) considering the items mentioned in the boq. preparing ga / schematic structural drawings for proposed revisions getting client’s approval on complete set of ga / schematic drawings sharing design, analysis and ga / schematic drawings to clint appointed structural designer for vetting and incorporating suggested recomendationa and implementing the same before issuing the gfc drawings. preparing working drawings ( structural ) for proposed revisions nominal changes to accommodate in the drawing, if any, as per client’s requirement visiting site to inspect the execution work. total visits 3 nos. issuing stability certificate only after completion of work to our full satisfaction. , preparatory civil , preparation of existing rcc wall or brick wall surface, by scrapping, existing finish / paint cleaning the exposed concrete surface to remove any fungus, loosely particles, scales, by a stiff wire brush, clean by water wash the entire surface, exposed the damaged concrete surface with the help of small chisel and hammer, including collecting, stacking the debris at the site. , carefully removing or chiseling, existing plaster of thickness up to 20 mm from the damaged surface with the help of small chisel and hammer weighing not more than 5 pound, includingcollecting, stacking & carting away the debris from the site wherever required as directed by site incharge , removing existing flooring & skirting tiles, along with backing and bedding mortar, clean the surface, lifting & shifting debris to ground floor & carting away the same out of premises etc. complete. , breaking & removingexisting rcc wall by mechanical cutter without disturbing the adjacent structure, or any other concretemembers including cutting ofreinforcement bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. ( 30 mm thk ) , demolishing the existing brick wall along with plaster bymeans of chisel &hammervery carefully, properplatform to collect the debris , lowering down & carting away the debris etc. complete. , brick wall 230 mm thick , brick wall 115 mm thick , carefully excavating in any kind of soil, in existing building in or out sides, including necessary shoring / propping if required and including carting away the debris including re making the surface in good as same as existing as directed. including dewatering and necessary back filling complete , dismantling of existing wooden / aluminium doors and handing over to the client as directed by pm. , labor charges for shifting the furniture remove all the cupboards and shift the same as directed to facilitate the work. , dismantling existing terrace water proofing including aap membrane, cleaning the roof top free from dust and dirt with mechanical wire brush make it receive new concrete, shifing of debries from terrace to ground and carting away out of actrec campus complete as directed and instructed. , construction civil , leveling and filling of earth below foundation and plinth level with quarry dust mixed with 5% cement ( by volume ) for the depth of 150 mm. after initial fill of 75 mm thick, pour water with required compacting, watering make the sub soil in good condition, pour water to dampen the dry mix enough to cake form. similarly fill second layer of 75 mm. pour water with required compacting after each stage of layer to make the mix damp enough to become solid form , providing and laying p.c.c. m15 ( 1:2:4 ) concrete in foundation as leveling course 150 mm thick including necessary form work, batching, mixing, placing, consolidating etc. complete including wet curing for specified time period. , supplying, providing and placing in position rmc m25 reinforced cement concrete with 20mm downgraded aggregates for walls of accelerator and maze rooms of thickness ranging from 300mm to 600 mm at all levels including vibrating, curing, providing construction joints, leaving cut outs / pockets for placing of inserts / embedment, etc., complete, including cost of providing steel form work with plywood lining for all shapes ( including scaffolding, centering, etc. ) , but excluding the cost of providing reinforcement all as per specifications.include precautions to control heat of hydration and obtaining a homogeneous compact concrete. all exposed concrete surface to be of form finish complete as directed and instructed. , for foundations , for rcc shielding , for terrace shieling , providing and fixing high density ( 7.75gm / cc ) steel plate to the existing concrete surface using holdfast and hot press technique. also, the footing required to carry weight of steel plate would be included as per approved design by the consultant. , supply &fabricating and fixing reinforcement for rcc work with high yield strength ribbed cold twisted tor steel of variousdiametersand all lengths of grade fe 415 / fe 500 conforming to bis specification including cutting, bending, fabricating, welding, wastage and placing in position according to drawings and binding the reinforcement with the use of 16 gauge galvanized binding wire of double fold and providing precast cement cover blocks for main reinforcements to ensure specified cover according to relevant is code.the measurements will be in accordance with is code 1200. , supplying, drilling / cleaning hole and injecting chemical laced heavy duty stainless steel anchor fasteners widely used in strucutral reahabilitation works to support re bars and strenth enough to support additional concrete throug mechnical drilling into exisitng concrete surface. the application to be designed separately for rebars as simply supported, moment or splice connection as per indian or european standard or relevant tested and accepted rebar guidelines. rebars. of 20 mm dia 200 300mm depth. the appointed strucutral designer should submit the detailed design analysis adopted, complete as directed and instructed. , providing and doing brick work with locally available good bricks of class designation 50, in required thickness of walls, in cm 1: 4, including adding polymer admixtureat 500ml per bag of cement, racking the joints, cleaning, carting away the wastages and curing , for 230 mm thick , for 115 mm thick , providign & constructing solid cement concrete block of m 10 grade of required thickness in cm 1:6 with scafolding, labour work at all heights and levels including wastage, scafolding etc omplete as directed and instructed. , providing and doing pressure groiuting with waterproofing compound or structural reapiring compund as per manufacturers specfication as directed by the structral consultant, withinsertion of pvc nozzles with drilling holes at regulaer intervals on exisit g rcc walls, beams, roof slabs etc complete as directed and instructed. ( cosnidered for exsitng rcc walls which are developed cracks. ) , providing & applying plaster at an average thickness of 12 to 15 mm in exact line & level in the proportion of 1 : 4 cement and sand mortar by manual mixing, with addition of waterproofing chemical @ 150 ml and harbourite 12 mm fine fibrillated 100% virgin polypropylene fibers @ 150 gm per bag of cement including curing for at least 7 days, carting away a debris, cleaning ( note: waterproof plaster considered in server room only ) , filling sunken portion of roof with brick bat mixed with cm 1:6 and complete as directed and instructed , providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , miscellaneous civil , providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge. , supplying, providing and laying vitrified tiled floor, wall on cement screed using 600 x 600 mm vitrified tiles. total thickness of screed and tiles to be 30 mm. including lying 125mm high skirting all round. laid area of wall, floor and skirting measured and paid , wall tiling ( 1.8 mtr height ) , floor tiling , providing and fixing floor cover with quick access to sub floor utilities galvanized steel chequer plate for cabling modular factory finished widely for cabel laying to withstand heacy traffic movemetn of heavy matirials thelid has been designed to withstand for heavy loading, all lids are galvanized to prevent corrosion, with the larger lids having substantial underbracing to give the required strength, complete as directed and instructed. , providing and applying pest and rodent control for the required in all respect including guarantee for the 18 months , providing & layi g approved shade minimum 18mm thick granite slab in flooring, window cills etc over cement morter of 1:4 in wastage, labour. complete as directed and instructed. , provide and fixing wall paneling up to the ceiling height in radiation therapy processing room, passage and the control room, using 18 / 12mm thick high quality plywood paneling with 4mm thick veneer finished, cut to shape and size and fixed to wall in straight line including all supports, screws etc complete as per direction of engineer in charge. , p / f trap door in false ceiling with acp panel in shutter and frame fixed ovwr 50x50x2 mm thick aluminumhollow swction with epoxy sealant as per manufacturer specification suspended from ceiling with suitable ms supporting system as per site condition, including p / f 32mm thick insulation on trap door complete as directed and instructed. , painting , providing and applying oil based internal paint as per the manufacturers specification to the interior surface of masonry walls, underside of roof slabs in ups room , control room , passages, of approved colour and shade with minimum two coats of paint. item to include preparing the surface with necessary approved fillers, making good by touch up etc. to give the desired finish , all complete. rate to include cost of the tools, tackles, labour, equipment, etc. ( above wall tiling ) , providing and applying exteriorpaint widly used to mactch exisitng colour schemewaterproofing paint, scrap and clean the surface, applyprimer as base coat, over the primer coat apply two coats or more paint approved color as per manufacturers sepecification all inclusive of labour, scafolding, safety precautions etc complete as directed and instructed. , providing & applyingenamel paint to wooden or steel doors, scrapping, cleaningthe surface, washingandfillingthe crevices with approved paste / putty as filling sealant & applying the paint with one metal primer base coat, two top coats or more over the primer as per manufacturers specification, including, labour, scafolding, safety precaution etc complete as directed nd instruted. , furniture , providing and fixing 5w x 7h, 38 mm thick, double leaf doors in solid hard wood core ( phenyl formaldehyde bonded ) flush shutters both faces commercial ply including ist class c.p.t.w. lippings all around, lock plate and complete hardware, finished with both sides 1.0 mm thk. laminate as per specifications with grooves and clear / frosted glass as per design / detail complete in all aspects with necessary heacy duty hardware fixtures to mactch exisitng hardware fixtures already installed to maintain unifarmity as standerdization as per per the furniture drawing complete as directed and instructed. , repairing and alterations to existing wooden doors, by changing ss hinges, ss fittings and shutters to be 40mm thick, flush type with teak veneers on both sides open type. inclusive of fixing heavy duty automatic door a closure, two doors handles per shutter concealed night latch locking device, etc. complete. , floor mounted storage cupboards within bhabhatron room; to store: accessories. ( location: tomotherapy room passage ) size: 200 cm wide x 250 cm high x 60 cm deep ( 19mm thick commercial grade ply ) , open type cabinetwith shelves with 18 mm thick high quality plywood laminated with 0.9mm thick melamine laminates on both side of approved colour and make with 1 numbers of open type shelves 210cmx200x50cm size with 6 horizontal and 3 vertical partitions inside the therapy room with partitions for immobilization devices, electron applicator and cutouts. type and utility should match with the existing work station. provide necessary drawer 2 nos and shutter 2 nos as per the requirement from the radiation physics division. edges should be finished by machine press. all finishes and quality to be instructed by the engineering in – charge. , providing and supplying officers chair with net back revolving type.the contractor shall furnish one year warranty. economically designed and mat finish. , changing room partition ( 3x4 ) , electrival & lv works , main distribution lt panelsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 1 no 250a tp 25ka mccb + neutral link with built in adjustable o / l, s / c & e / f. mccb with rotary handle mechanism. outgoings : 1no 125a tp mccb with rotory handile machanism for ups, 1no 100a tp mccb with rotory handile machanism for chiller, 1 no. 125 a tpn mccb for hvac & 1 no 63a 25ka tpn mcb with mechanism for hvac unit. busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium .incoming and outgoing cables shall be top of bottom entry only. , ups output panel boardsupply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 1no 125a tp 25k mccb + neutral link with built in adjustable o / l, s / c & e / f mccb with rotary handle mechanism outgoings : 1nos. 100a 25ka tp mccb with rotary handle mechanism, & 3nos. 40a tpn mcb for db busbar : busbar rating shall be 1.2 sqmmper amphere formain bus bars with aluminium . incoming and outgoing cables shall be top of bottom entry only. , electrical wiring & cabling , distribution boards supply, erection, testing and commissioning the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adaptor box above the db shell also be includeddistribution box 8 way 7segment mcb dbi / c 63 amp fp mcb 1 noo / g 63 amp dp mcb 3 nos o / g 10 / 16a sp mcb 18 nos including all interconnections and other accessories etc as reqd , supply, installation, testing andcommissioning 100a tpn mccb with water proof enclosure including earthing and all other required accessories as per site conditions. for near chiller , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , lt cables supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4r 50sq.mm copper flexible cable truebeam ups incoming & outgoing , 4r 25 sq.mm copper flexible cable for ups input & output and machine , 1c 25 sq.mm copper flexible cable for earth , 4c 16 sq.mm copper flexible cable for chiller , 4c 10 sq.mm copper flexible cable for ac , 4c 6 sq.mm copper flexible cable for db , 12c 0.75sqmm copper flexible cable with pvc conduit for chiller to control panel at console room & warning light , 1c 6sq.mm copper flexible cable for db earthing , cable terminationssupply, erection, testing and commissioning for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4r 50 sq.mm copper flexible cable , 4c 25 sq.mm copper flexible cable , 1c 25 sq.mm copper flexible cable , 4c 16 sq.mm copper flexible cable , 4c 10 sq.mm copper flexible cable , 4c 6 sq.mm copper flexible cable , submain ups and raw power circuits , supply & laying of 2r 2.5sqmm 1r 2.5pvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. , supply & laying of4 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , point wiring supply, installation, testing & commissioning of 3r 1.5sqmm pvc insulated frls copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site. , primary point , secondary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1no13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. ( ups power ) , supply, installation, testing & commissioning of 1no 6 / 16a socket and 1no switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. , installation of light fittings , supply, erection, testing and commissioning of 2 x 2led 36 watts recessed mounting fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed. , supply, erection, testing and commissioning ofled 18 watts recessed mounting down light fitting with all accessories and interconnecting with 3 r 1.5 sqmm pvc insulated frls copper wire manufactured, used widely across campus to match exsitng pattern and design as standerdization complete as directed nd instructed , supply, erection, testing and commissioning of single3w recessed fixed type led fitting with electronics ballast and all accessories and interconnecting with 3 core 1.5 sqmm pvc insulated frlscopper wire and fixing the same in the ceiling. , data, voice & network , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. , supply, fixing, testing and commissioning of information outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 4u communication rack , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , supply, fixing, testing and commissioning of cat 6 telephone cable . , supply & fixing of 24port patch panel and 10 / 100 / 1000 mbps base t switch with 24 port patch panel , earthing , supply and installation of 4 way earth bus with accessories as required , supply, installation, testing & commissioning of copper earthing with 600x600x3mm copper plate and 25x6mm copper flat bar confirmingis:3043 with the provision for watering & inspection chamber. , perforeated type gi cable tray , supplying, fabricating, erecting and connecting the following 1.6mm thickness gi perforated type cable trays with necessary supports, tees, elbows, bends, bolts and nuts and any other associated accessories to complete the job. 150mm ( wide ) x 50mm ( collar height ) , supply & fixing of 50 mm pvc pipe for cc tv, irm and speaker cable pulling , warning light supplyfixing testing & commissioning of warning light, led green, yellow, red, + power supply . , emergency stop switch supplyfixing testing & commissioning of emergency switch, 3 no. no, element with box , supply fixing & commissioning of lmo switch indicator &buzzer, ss plate with all accessories , supply, laying, testing and commissioning of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 10 sq.mm copper flexible cable for ac , 1c 6sq.mm copper flexible cable for db earthing , supply, installation, testing and commissioning 63a tpn mcb with ms enclosure including earthing and all other required accessories as per site conditions for ac outdoor unit , supply testing & commissioning of panasonic make telephone instument with caller id , cctv the camera should be compitable with exisitng cctv system as standerdization, sample must be got approved before supply in bulk. , 16 channel dvr ful hd , hd outdoor bullet camera , hd dome camera , wd hard disk ( dvr ) 1tb , moniter ( 19.5inch ) , camera power supply ( 10amp ) , sdmi cable ( 3 meter ) , bnc conector , dc pin conector , wire 3+1 ( heavy wire ) per / meter , junction box for camera , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1 no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplid. , supply testing commissioning of token display system , firefighting works all devises should be compitable with exisitng system as standerdization, sample must be got approved before supply in bulk. supply, installation, testing & commissioning: , smoke detectors bunker 8 nos; maze 2 nos; ups 2 nos. , response indicator. , manual call bell , hooter , cu. ar. 1.5 sq.mm. cable , fire extinguisher 5kg bunker 4 nos; ups 1 no. , hvac works , supply, installation, testingandcommissioningofaircooledscroll chilling machines having actual capacity of 38.4 tr at chilled water inlet / outlet temperature of 12.0 deg. c / 7 deg. c having evaporator fouling factorof0.000018m2.k / w suitable for operation on refrigerant r 407c or eco friendly gascomprising the following complete as required. chiller capacity should not less than 38.4tr ( followingsafetyfactorwillinbuiltwithchillerunit sppr, under / over load protection, phase reverse protection, hp / lp trip signal interlocking, auto / manual test mode facility / run time equalization for multiple compressor, password access for authorized handling, pt 100 rtd sensor for chiller unit, interlocking for chilled water flow swtich ) 135kw ( 38.4tr ) , air handling units supply, installation, testingandcommissioningoffactorybuiltfloor mounted doubleskintypehorizontal / verticalairhandlingunits made of43+2mm thick panels consisting ofpreplasticizedg.i. casing of thickness 0.8 mm outside layer and 0.8 mm plane gi at inside layer with cfc free p.u. insulation of density 42 ( +5% ) kg / m3 factory injectedbetweenthem byinjectionmouldingmachine, completewith didwbackwardcurvedcentrifugalfanwithvfdstarterdriven, suitablefor50mm wgstaticpressure, coilsectionwithaluminium blue finned copper tubes ( tubes thickness not less than 0.41mm ) cooling coil of 6 row deep, filter section with 50mm thick washable synthetic type air pre filters, belt drive package with tefc drive motor suitable to operate at 415 ± 10% volts, 50hz, 3 phase ac supply, motor should be compatible with vfd, drain connections, stainless steel ( 18g ) drain pan, necessary vibration isolation pads & accessories:and piping as per the norms duly insulated with requires thick nitrile rubber. ahu starterpanelshouldhavevfdandvfdbypassoption, should have plc based control and plc bypass control for manual mode. panel should provide with heater control. note: temp and rh sensor to be included with control wiring. noadditional cost will be given for the same. 30.5 tr 12200cfm 50mm tsp ( 1 working +1 standby motor ) , supply, installation, testing and commissioningof fcu 2 tr , supply, installation, testing and commissioningof primary pump 102usgpm 15m head. , supply, installation, testing and commissioningof expansion tank ( 100 ltr ) with air separator, air vent and pressure maintaining pumping unit. , supply, installation, testing and commissioning of chilled water ms pipe with supports, hardware etc. , 80 mm dia with 32mm nitrile insulation with 26g al cladding , 25 mm dia with 19mm nitrile insulation with 26g al cladding , pvc drain pipe having pressure holding of 8kg / cm2drain piping complete with all accessories with 9mm nitrile rubber insulation with supports , 32mm dia , 25mm dia , supply, installation, testing and commissioningof valves & guages as follows with 32mm nitrile insulation for chw line: , butterfly valve , 80mm dia , 25mm dia , y strainer , 80mmdia , 25mm dia , flexible connection80mmdia , nrv valve80mmdia , 3 way valve , 80mm dia , 25mm dia , ball valve 25mm dia , airvent with ball valve , temperature gauge , pressure gauge , sitc of gi sheet metal rectangular duct with support, hangers, rods, frames, anchor fastners, etc. , 24 gauge , 22 gauge , supplying & erecting accoustic insulation lining on the ducts having 15mm thick open cell nitrile rubber armasound to reduce noise , supplying & erecting thermal insulation on the ducts having 19 mm closed cell nitrile rubber. exposed duct should cover with 26g al cladding , sitc of canvass connection for ahu machines , sitc of control cabling in between for fcu and ahuunits , sitc of fire damper , sitc of fire actuator , sitc of supply / return air grill with vcd , supply, installation and commissioning of duct strip heaters with thyristor control of necessary capacity made of ss strip ( finned / finless tubular type ) complete with rh sensor, industrial grade heating elements, protection against overheating, on / trip status, air flow switch, grounding terminals, terminals for power & control, intermediate control wiring for integration etc. for full automation working to achieve rh level of 40 60% non condensing in the treatment room. ( rating / capacity considered to be specified by the bidder ) , dismantling of existing hvac systems ahu, piping, valves , ducting / copper piping / drain piping / units / hi wall split unit all complete as per instruction as nad directed by oic es , supply and fabrication of ms structure include one coat primer and one coat enamal paint. , dismantling & re installing exisitng ac chiller plant including its roofing at terrace including disconnection of chilled water ms pipe lines, extending same till new location, with required insulation and necessarru hardware as directed and instructructed. , turnkey works at tmh mumbai , civil works : , labour charge only for removing and re fixing available door shutter with necessary modification including cutting the existing shutter providing leeping patti all around the shutter if required including removing and refixingavailbale old hinges, mortice lock, tower bolts ect. fixing aligning the door shutter in proper plumb and level etc. complete allonly fixing available door shutter with necessary repairing , removing existing false ceiling of any material and any size with all necessary allied works, removing out debris out of tmh premises , labour charges only for carefully removing and taking out existing wooden partitions ( partly glazed, partly panneled or fully panneled with shutters glazing etc. at all floor levels and locations including removing the existing mongery fittings fixtures locking arrangement and handling over the same to t.m.c all complete as directed , providing wood work with 1st class c.p. teak wood in frames for doors windows, ventilators, air condition frames, clear story window, false ceiling and partitions etc.wrought framed and fixed in position including applying one coat of approved wood primer to the exposed surfaces and tow coats of bitumastic paint to the surface of wood in contact with masonry / concrete etc.complete. in frames of doors, windows, ventilators and clear storey windows etc. fixed with m.s hold fast of size 40x3mmx150mm long bend to shape and embeded in cement concrete 1:2:4. , providing and fixingapproved quality machine pressed phenol formal dehy de bonded commercial / marine ply wood of approved size and fixing the same with necessary nails / screws / adhesive in partition cupboard shelves / ktichen / cabinets / flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick t.w.lipping patti at all exposed edges with nails / screws / hardwares / adhesive wastage in cutting, transportation etc. complete all.commercial ply19mm thick ply , providing and fixing 1.0mm thick laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified. 1.00 mm thick , providing and fixing cabinet made up of 19 mm. commercial ply for top, bottom, sides and shelves and 6mm commercial ply for back side.door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.0mm thick plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in drawing etc.and all exposed edges lipping with 6mm laminate finishthick t.w.lipping patti.locking arrangement withmultipurpose lock etc. all inside areas shall be .80mm thick approved colour laminate etc. with inner side 0.8mm thick laminatewith shutter , providing making and supplying computer table made out fo 19mm commercial ply for table top, mounted on the vertical side fo 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves and shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polishasshown in drawing drawer and wooden key board drawer with heavy sliding channels, withhandle for shutter, cable manager drawers all edges shall be lipped with 6mm thick t.w. lipping patti. all exposed faces should be 1.0mm thick laminate and non laminated area should be french poll shed including cost of other materials labour etc. as per drawing.computer table with all inner surface with 0.8 mm thick laminate , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings.gi metal ceiling lay in plain tegular edge global white color tiles of size 595x595 mm, and 0.5 mm thick made of g i sheet having galvanizing of 100 gms / sqm ( both sides inclusive ) and electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending. , providing fixing door frame and shutter side hung to consist of partly glazed partly panneled / fully panneled / fully glazed with 5.5mm thick glass sheet and quality plain or frosted of bajri glass fixed with two way pvc lining / rubber gasket to ensure notes tightness and no rattaling and panneling with 12mm thick nova pan or ancholam finished on both side as required using extruded alumimium section forshutter frame24254545mm satin finish anodized including p / f push pull plates handles and heavy duty fittings like tower bolts, motice lock with keys hinges of 5 inch or 6 inchas per requirement hydraulic door closer / floor spring of suitable capacity etc complete.with powder coated , painting work providing & applying one / two coats of primer two coats of paint as mentioned below first quality paint to the required colour scheme and as per manufacturers instructions / specificationsto the walls, beams, columns, ceilings, partitions, doors etc. including removing existing paints , nails , screws , battens etc. and thoroughly scrapping the surface with sand papers filling up crevices and levelling with putty to obtain smooth surface ie. complete surface preparation etc. complete as directed to the entire satisfaction of engineer in charge. , with two coats of primer and two coats ofpaint , using luster paint , using synthetic enamel paint ( oil paint ) , providing and applying three coats of white wash to ceiling etc. including removing existing nails , screws , battens etc. andthoroughly scrapping the surface with sand papers, filling up the crevices and levelling with putty if necessary adding, required quantity of adhisive to obtain good finish to surface complete as directed. , civil work breaking:dismantling carefully the existing damaged cracked serviceable tiles / slabs / clay tiles / marble slab / granite slab / kota stone / tandur stone / shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including disposing / taking away the debris outside the premises & disposing as per the guidlines of statutory authoritised. ) , granite tiles:providing & laying 8 to 10mm thickgranite tile of size 300mm x 600mmfor flooring / dado / skirting laid over a bedding of c.m. 1:335mm thick in true plain line & level curing. finishing the joints etc. complete.in flooring & in dado / skirting , electricalsworks , point wiring : point wiring for light / fan / bell with isi mark 3 x 1.5 sq.mm ( p+n+e ) . frls pvc insulated copper conductor ofmake in surface / recessed heavy class pvc casing capping / conduit with modular switch ceiling rose / batten holder / slanting holder boxes etc. with circuit labling / marking / ferruling complete. , primary point upto 4 mtrs length , primary point length 4 mtrs to 7 mtrs , primary point length7 mtrs to 10 mtrs , secondary point extending from primary point upto 4 m , dismantling: carrying out assigned jobsof dismantling the existing light, fan, bell, independent plug point wiring of all types with accessories and cable / switchgear , supply & installation of power point ( inclusive of 2no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , supply & installation of power point ( inclusive of 1 no.of 15 amp switch socket, back box, face plate & wiring, accesories etc ) , telephone point : supplying and instllation of telephone point inclusive of telephone instrument, telephone socket with back box , plate, laying two pair0.5 mm gauge unarmoured telephone wire d.o.t approved, make through conduit / casing caping. , supplying and laying of 2 core audio speaker cable throughconduit / casing caping / cable tray. , sub mainsmains : providing heavy duty pvc casing caping / conduit, supplying and erecting mains with copper conductor pvc insulated frls of 1100 v ac grade wire with circuit labling / marking / ferruling complete. , 2 x 1.5 sq mm + 1.5sqmm earth wire , 2 x 2.5 sq mm + 1.5sqmm earth wire , 2 x 4 sq mm + 2.5 sqmm earth wire , light fixturessupply of led fixtures surface / suspended / recessed mounted luminaires , led light fixture duraslim 15 watt, round6500k, , led light fixture full glow 2ft x 2ft 6500k , distribution boards supply, installation, testing & commissioning dbs , spn db with metal door, 12 way, ip 43, inclusive of required rating mcb, rcbo , tpn db with metal door, 8 way, ip 43, inclusive of required rating mcb, rcbo , hvac works , hvac works ( low side ) fan coils units ( ceiling suspended type / high wall ) supply, installation, testing and commissioning of gi powder coated horizantal ceiling suspended / high wall fan coil units complete with fan, 3 speed motor, 3 row deep cooling coil, 5 mm external static, filters , copper connection, canvass connection ( if required ) , supporting arrangement, electrical wiring etc. the complete fan coil unit shall be in line with the standard specification. the capacity of fan coil units shall be as follows. proper supporting system for fcu to be provided & will be in contractors scope. 800 cfm ( 2 tr ) , hvac works ( low side ) : supply & installation of 2 wayvalve , hvac works ( low side ) : supply & installation of digital thermostat including all accessaries , mountings, wiring between thermostat & unit, terminations etc. , supply, installation testing and commissioning of the following ball valves without strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , supply, installation testing and commissioning of the following ball valves with strainer duly insulated as per specifications and drawings. it shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. 25 mm dia , hvac works ( low side ) :supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class o applied by suiatable adhesive, as per specifications and as required complete in all respect 32mm, insulation work involve removing of old insulation on chilled water pipeline and installing new insulation. , hvac works ( low side ) : providing and fixing in position the following upvc heavy class cut to required length and installed with screw joints including the necessary fittings, supporting arrangements like clamps etc. ( bends, tees, unions, sockets etc ) duly insulated with class o 6 mm thick nitrile rubber insulation as per specifications. 25 mm dia , hvac works ( low side ) supply, installation, balancing and commissioning offabricatedat site gss sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of .63mm thickness complete as required. , hvac works ( low side ) supplying, installing of external thermal insulation on ducts of al faced / closed cell nitrile rubber insulation with anti microbial properties with duct insulation with density 40 55 kg / cum complete as per specifications. •thermal conductivity of insulation material shall not exceed 0.035 w / ( m.k ) & r value as mentioned in ecbc 2008 at mean temperature of 24 degree c as per astm c518. . class o insulation with aluminum foil. • moisture diffusion resistance factor or ‘?’ value of insulation material shall be minimum 7, 000 without any external barrier as per en 13469. • the insulation material shall have fire performance such that it passes class 1 as per bs476 part 7 for surface spread of flame and also passes fire propagation requirement as per bs476 part 6 to meet the class ‘o’ fire category. 25 mm thick. , hvac works ( low side ) supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 300 mm dia , hvac works ( low side ) supplying, fixing testing commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. , hvac works ( low side ) supply, installation, testing and commissioning of gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications , dismantling, removing of oldflexible ducting , pipelne, insulation, fcu ( 3nos ) , griil, diffuser etc loading, unloading, lifting shifting, etc and disposing the same outside tmh premises with proper housekeeping complete in all respect , networking supply, installation, testing and commissioning of lan cable room no. hbb b 002 4 nos. of network points, room no. hbb b 003 2 nos. of network points. total networks points. = 6 nos. , turnkey works for site preparation of gmc, shillong , civil shielding works , complete dismantling works inside bunker and console room, of plain cement concrete, flooring, brick work, false ceiling to any depth and width, at all levels below & above ground level of any shape, removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. rate shall include for dismantling of plain cement concrete / brick work by manually / mechanical means with necessary tools and plants, scaffolding, water and power charges, cleaning the surface, preparation of surface etc. rate shall include for stacking the serviceable materials and disposing the unserviceable materials / debris away from the site premises by mechanical means including loading, unloading, clearing the site etc. complete, as directed. ( measurement is done for floor area only ) demolishen of the walls are as per approved drawings , providing and casting in situ cement concrete m 25 ( concrete density 2.35 gms / cc ) of trap / granite / quartzite / gneiss metal for r.c.c. walls as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing complete. ( excluding reinforcement ) . with fully automatic micro processor based plc with scada enabled reversible drum type concrete mixer. with natural sand. for concrete shielding and bunker door wall as per aerb approved drawing , providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the rcc structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 ( 5 parts integral crystalline slurry : 2 parts water ) for vertical surfaces and 3 : 1 ( 3 parts integralcrystalline slurry : 1 part water ) for horizontal surfaces and applyingthe same from negative ( internal ) side with the help of synthetic fiberbrush. for bunker and console area , civil interior & furniture works , 50mm thick cement concrete flooring finished with 3mm thick vinyl flooring location: ups room , 600mmx 600mm vitrified tiles with 100mm matching tile skirting. providing and laying approved quality, colour, design and shade fully homogeneous 600 x 600 mm ( thickness to be specified by the manufacturer ) vitrified tile flooring ( marbonite or granamite, confirming to is code 15622 with water absorption less than 0.08% ) flooring in pattern as detailed in drawing or as directed by the institute and grouted with matching colour approved quality readymade grout, curing, cleaning etc to required line level etc. all complete at all leads, lifts and heights to the entire satisfaction of the institute. providing and fixing 2 3mm thick pop protection over polythene covering sheet to flooring areas till handed over and cleaning, etc all complete as per drawings & specification. ( linac room and console room ) , two coats of plastic emulsion paint over 2 coats of wall putty including primer. location: ( ups room and outside shielding wall ) , providing and laying high quality and density type vitrified wall tile of 1200 mm height in radiation therapy room and the control room, laid on 20mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) or as per the appropriate mortar rquired to hold the wall tiles together, in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge upto false ceiling level. location: ( linac and control console room ) , pest and rodent control from pci location: linac room, control console and ups room , acoustical tile for ceiling with light weight insulating material of high quality supported on grid or finished seamless with support above ceiling. to be finished with white paint or powder coated with white paint, if metallic. the false ceiling panels should be of reputed brands. location: linac room, control console and ups room , constructing cable trenches 300mm wide and 300mm deep as per the drawings , preparing and fixing openable covers of vitrified tiles fixed in the with ability to sustain a load of 200kgs to be placed on the trenches 300 mm wide, all works complete , furniture , revolving chairs height adjustable, medium back with hand rest , skylight , wall mounted storage cupboards within linac room; to store: dosimetry & qa items, linac accessories. ( location: treatment room ) . size: 2m wide x 1.2m high x 0.4m deep ( 19mm thick marine grade ply ) , 40mm thick plywood door with teak wood frame, including all accessories. size 2m x 2.2m , wooden tables for workstations. size: 3 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: console , wooden tables for workstations. size: 4 m wide, 0.6 m deep and 0.8 m high ( 16mm thick marine grade ply ) for: tps , plumbing works , supply & installation and commissioning of chiller inlet & outlet equipment flange & union , supply & installation and commissioning of pressure gauge , supply & installation and commissioning of thermometer , supply & installation and commissioning of auto air vent , supply & installation and commissioning of drain valve , supply & installation and commissioning of chiller water copper piping 15 / 8 18 gauge with insulation 19mm thick , supply & installation of chiller water pipe nylon with wire mesh hss slive flexible 40mm with insulation 13mm thick , supply & installation and commissioning of ball valves 40 mm , supply & installation and commissioning of y strainer 40 mm , supply & refilling of dm water , supply & installation and commissioning of water panel with 2 nos pressure gauge and 5 nos valve, 2 nos thermometer , hvac works , ductable a / c units along with low side works ( up to 50 running meters ) for complete installation & commissioning of ac. supply , installation , testing & commissioning of aircooled ductable split air conditioner with ceiling suspended idu and all standard fitting, gss sheet metal duct ( insulation using resin bounded glass wool with 7 micron aluminium foil ) for air distribution 22 / 24 g, idu ss drain pan as per specification complete with suitable capacity drive motor , aircooled condensor with all accessories , hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, vibration isolator pads, structural support for fixing idu / odu, safety devices including thermal protector, pressure release valve , overload relay single phase preventer etc, power wiring and control cabling ( indoor to outdoor ) , thermostat wiring, high low pressure cut out suitable for 3 phase 440v supply etc complete as required. ( warranty 3 years ) for bunker and console 5.5 tr working and 5.5tr stand by , split units with required copper piping and drainage outlet lines ( for ups room 2tr working and 2tr stand by ) with auto timer switch , 2 litre capacity dehumidifier ( for bunker 2, console 1 ) , electrical works , main lt panel supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. main distribution panel consisting of the following. incomer : 250a 3p mccb with rotary handle mechanism 1no with necessory interlocking arrangement out goings : 100a tpn mccb with rotary mechanism 2 nos. 63a tpn mccb with rotary mechanism 3 nos. 40a tpn mccb with rotary mechanism 1 nos. incoming and outgoing cables shall be of top or bottom entry only. , ups output panel board supply, erection, testing and commisioining of cubicle type free standing, dust and vermin proof, busbar chambers, shell made of 14swg crca sheet, doors made of 16swg crca sheet with powder coating, compartmentalised, modular type ip 42 protection, with support clamps and angles frames as required as per the site condition. ups output panel consisting of the following. incomer : 100a 3p mccb with rotary handle mechanism 1no out goings : 100a tpn mccb with rotary mechanism 1 nos. 40a tpn mccb with rotary mechanism 2 nos. incoming and outgoing cables shall be of top or bottom entry only. , distribution boards supply, erection, testing and commisioining the following mcb dbdouble door type, ip 42 powder coated comprising of fixed flush with the wall. the cost of providing adoptor box above the db shell also be included , power & lighting dbs 6 way etpn mcb db, all mcbs shall be of c curve type only meant for lighting application i / c 63 amps fp mcb 1 no o / g 6 / 10 / 16 / 25asp mcb 18 nos including all interconnections. , ups dbs 4 way etpn mcb db, all mcbs shall be of c curve type only meant for ups power application i / c 40amps fp mcb 1 no o / g 10 / 16asp mcb 12 nos including all interconnections. , supply, installation, testing andcommissioning 100a 4p mcb with water proof enclosure including earthing and all other required accessories as per site conditions.for a / c & chiller , supply, installation, testing andcommissioning 100a mccb with ms enclosure including earthing and all other required accessories as per site conditions. for ups incoming & outgoing , l.t.cables supply, laying, testing and commisioining of 1100v pvc insulated xlpe and sheathed armoured copper / aluminium conductor cables laid overms supports / cable racks / fixing of walls including clamping the cable to the support in all approved manner as all , 4c 4 sq.mm cu. ar. cable ups db incoming , 4c 10 sq.mm cu. ar. cable for pdb & hvac input cable , 4c 16 sq.mm cu. ar. cable for chillerinput cable , 4run 25 sq.mm copper flexible cable machine incomming & outgoing wiring , 4run 25 sq.mm copper flexible cable ups incomming & outgoing wiring , 1run 25 sq.mm copper flexible cable for earth cable , 4 core 50sq.mm copper ar. cable for upsin & out going power cable , cable termination supply, erection, testing and commisioining for the following sizes of 1100v pvc insulated cu / al. conductor cables including providing single compression type cable gland copper sockets for copper cables, crimping lugs, insulation tape including gland , 4c 4 sq.mm cu. ar. cable , 4c 10 sq.mm cu. ar. cable , 4c 16 sq.mm cu. ar. cable , 4run 25 sq.mm cu. flexi. cable , 1run 25 sq.mm cu. flexi. cable , 4 core 50sq.mm al. ar. cable , submains ups & raw power circuts , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( lighting & raw power circuit mains ) , supply & laying of 2r 2.5sqmm 1r 1.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( ups circuit ) , supply & laying of 2r 4sqmm 1r 2.5 sq.mmpvc insulated frls multistrand copper wire with 25mm dia frpvc conduit with all accessories as required as per site conditions. ( split a / c / power socket circuit ) , supply & laying of2 run 1.5sqmm pvc insulated multistrand copper wire with 20mm dia pvc conduit with all accessories for emergency push button wiring. , supply & laying of3 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for lmo switch wiring. , supply & laying of8 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for warning lamp wiring. , supply & laying of12 run 1.5sqmm pvc insulated multistrand copper wire with 25mm dia pvc conduit with all accessories for chiller remote panel wiring. , point wiring supply, installation, testing & commisioning of 3r1.5sqmm pvc insulated fr copper wire with frpvc conduit along with modular6a one wayswitch with moulded front plate gi anodised enclosure and other associated accessories as required as per the site condition , primary point , dimmer light point with dimmer , sockets , supply, installation, testing & commissioning of 1nos 6a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( raw power ) , supply, installation, testing & commissioning of 1no 6 / 13a socket and 1no 6a switch and with moulded frontplate gianodised enclosure and other associated accessories in the work station as required as per the site conditions. bunker, consol room & tps room ( ups power ) , supply, installation, testing & commissioning of 1 no 16a switched socket with moulded frontplate gianodised enclosureand other associated accessories as per the site conditions. ( with indicator ) , installation of light fittings , supply, erection, testing and commisioining of 600mm x 600mm 36w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of 6 x 6 18w led light fittingalong with electronic ballasts with all accessories and interconnection , supply, erection, testing and commisioining of single12 v, 15w led fitting ( or ) 230v, 60wrecessed fixed type halogen fitting with copper ballast, lamps all accessories and interconnection ( dimmer light ) , supply, erection, testing and commisioining of led strip light , data, voice & network ( consile room & tps room ) , supply, laying, testing and commissioning of cat 6 utpcable with fr pvc conduit and all accessories as required. ( voice and data cable ) , supply, fixing, testing and commissioning of infermation outlet for cat 6 utp cable quader front plate with back box and all accessories as required. , supply, fixing, testing and commissioning oftelephone outletfront plate with back box and all accessories as required. , supply, fixing, testing and commissioning of 6u communication rack , supply & fixing of 10 / 100 / 1000 mbps 24port t switch with 24 port patch panel , supply of 1 mtr pach card , earthing , supply & laying of 8 swg bare cu. wire , supply and installation of 12 way earth bus with all accessories as required. , supply, installation, testing & commisioning of 10 feet long 600 x 600 x 3mm copper plate or chemical earth pit for machine and ups netural and body earth , miscellaneous , supply & laying of20mm pvc hose , supply & laying of25mm pvc hose , supply, fixing of 105 x 50 mm cms tray for control room , warning lamp em off switch & lmo switch , supply & fixing of emergency stop switch and system on switch with base box , supply and fixing of magnetic door switch , supply, erection, testing and commisioining of led warning lamp for red, green & yellow . , supply, , erection, testing and commissioning of last man out control unit, last man out switch with indicator, buzzer and external wiring kit ( 1.0 sq.mm cu. wire & pipes ) , fire alarm system , supply, fixing, testing & commissioning of 2 zone conventional fire alarm panel with complete set. , supply, fixing, testing & commissioning of conventionalsmoke detectors with base , supply, erection, testing & commissioning of conventional manual call point. , supply, erection, testing & commissioning of conventional hooter / sounders , supply and laying of 2 core 1.5 sqmm copper armoured cable , carbon di oxide type fire extinguisher of 4.5 kgs. capacity, co2 gas filled in brand new seamless cylinder with powder coated finish, made out of manganese steel, with wheel type valve, discharge nozzle, bend & horn, signages etc. complete, , cc tv , supply, fixing, testing & commissioning of hd ir ccd 1 / 3” color camera. ( doom or bullet modal camera ) , supply, fixing, testing & commissioning of hd mini speed dome ir camera. with 10 to 15x zoom, auto iris lens, rs485 control ptz camera , supply, fixing, testing & commissioning of 4 chenal hd dvr , supply, fixing, testing & commissioning of ptz keyboard with joystick , supply, fixing, testing & commissioning of 24” led tv , supply, fixing, testing & commissioning of 12v dc power supply for camera , supply and laying of 3+1 rg 58 cctv cable , tack / tack back system , supply, fixing, testing & commissioning of tack / tack back systems comprises of console with mike ( inbled amp. ) ceiling speaker or wall mount speaker 1no. , supply and laying of two core screened cable , audio system for playing soft music inside the treatment room, control console, patient waiting area also to be supplied. , turnkey works for site preparation of dr. b. borooah cancer institrute, guwhati , a ) civil works , demolishing rcc work including stacking of steel bars and disposal of unserviceable material as directed for all levels , dismantling and removing the existing door and window frame ( chowkath ) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. ( ii ) area of door / window above 3.00 m2 , demolishing cc floors of various thickness including top layer and base course and disposal of debris as directed for all levels. , providing and laying plain / reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately ) ( i ) using mixer machine ( a ) in substructure up to plinth level p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , ( b ) in super structure from plinth level up to 1st floor level.p ) using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b ) m20 grade concrete or prop. 1:1.5:3 , providing form work of 12mm thick plywood board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. ( b ) floors etc. above 200mm in thickness. , supplying, fitting and fixing in position reinforcement bars conforming to relevant i.s. code for r.c.c. work / r.b. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20g annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. ( no extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate ) ( upto 1st floor level ) a ) from primary producer ( i ) tmt corrosion resistant steel ( crs ) reiforcement bar , plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete ( shuttering where necessary shall be measured and paid separately ) . ( a ) in prop 1cement: 3 sand :6 coarse aggregate by volume , 20 mm thick cement plaster in two coats on single or half brickwalls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b ) on fair side ( backing coat 10 mm and finishing coat 10mm thick ) a ) in cement mortar 1:3 , providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile ) / white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. ( cement plastering to be measured and paid separately ) . ( coloured pigment should be in conformity with colour of slab and as approved and directed by the department ) . ( iii ) deluxe quality ( i ) with fix a tile , providing vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tilewhite cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) c ) delux range ii ) of size 1200mmx1600mm and above , providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 ( 1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix a tile / white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. ( coloured pigment should be in conformity with colour of tiles and as approved and directed by the department ) . iv ) of size300mmx900mm and above , supplying fitting and fixing of upvc partition wall 5 mm frosted glass , supplying fitting and fixing of upvc double leaf door 5 mm frosted glass , supplying fitting and fixing of upvc sliding door door 5 mm frosted glass , supplying fitting and fixing of upvcsliding window 5 mm frosted glass , providing wood work in frame ( chowkaths ) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with c.c or brick masonry wall including supplying, fitting and fixing with m.s. hold fast ( 40mmx3mmx250mm ) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with c.c and masonry as directed and specified. ( a ) with sal wood , providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent i.s code including oxidised iron butt hinges ( 100mm x 75mm x 3.5mm ) 6 nos with necessary wood screws. a ) decorative type face panel and block board core. ( iii ) 30 mm thick . , supplying, fitting, fixing and painting where necessary ( one coat primer and two coats of paint ) suspended ceiling which includes g.i. perimeter channels of size 0.55mm thick ( having one flange of 20mm and another flange of 30mm and a web of 27mm ) along with perimeter of ceiling, screw fixed to brick wall / partition with the help of nylon sleeves and screws, at 610mm c / c. then suspending g.i. intermediate channels of size 45mm ( 0.9mm thick with twoequal flanges of15mm each ) from the soffit at 1220mm c / c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with g.i.cleat and steel expansion fasteners. ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 298mm c / c. then 12.5mm thick square edge fulltone / sundance / cratone / louvertone / textured. gypboard panels of size 595mmx595mm ( conforming to is:2095 1982 ) is then screw fixed to ceiling section with 25mm long drywall screws at 290mm c / c. screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for gypboard complete at all levels as specified and directed. ( for light fittings, grill diffusers etc. cut out to be made with the frame of perimeter channel supported suitably and measured and paid separately as and where necessary ) . ( glass wool to be measured and paid separately ) . m / f frame work with acoustic type slit gypboard ( louvertone ) tiles ( nrc value 0.72 with 50mm glass wool mat backing ) 12.5mm thick. , providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. , wall painting ( two coats ) with plastic emulsion paint on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. ( a ) .plastic emulsion paint , extra over item no 13.4.7 above for every subsequent coat of wall painting with plastic emulsion paint. ( a ) .plastic emulsion paint , water proofing of chajjas, roof slabs, terraces, sunken slabs, septic tank, oh tank, raft slab in basement, walls etc. ( b ) using polymer based cement mortar. , supplying fitting and fixing of sky view , providing, fitting, hoisting and fixing of roof trusses fabricated out ofcombination of anytwo or all of the following sections ( i ) square section ( ii ) rectangular hollow section of specification rsh / shs and ( iii ) m.s. circular hlollow section of grade 210 including purlins, bottom runners and providing m.s. cleat, m.s. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a ) using rhs / shs of grade 310 conforming to relevant i.s. code 4923 : 1997 , providing pre painted galvanized ironsheetroofing ( ppgi ) at all levels including fitting and fixing with self drilling, self tapping screws complete. ( roof trusses, purlins etc. to be measured and paid separately. ) as directed by the departement ( v ) 0.80 mm thick , earth / sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. ( b ) with hill sand obtained by truck carriage loading and unloading, and carriage to the site of work. , providing soling in foundation and under floorwith stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. ( a ) .brick on flat soling. , 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure ( ii ) in superstructure above plinth level up to 1st floor level. ( a ) . in proportion 1:3. ( 1 cement:3 sand ) , supplying, fitting and fixing chain link fencing of 10 s.w.g, g.i. wire 50mm x50mm mesh fitted to m.s angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of g.i wire 10 s.w.g at top, middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to m.s angle iron post in p.c.c base etc. with following. a ) corner and end posts with m.s angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. , supply, installation, fixing of dry chemical powder fire extinguisher confirming to is: 2171 with isi mark and co2 cartridge will be confirming to is: 4947 with isi mark, powder will be confirming to is: 4308 with isi mark ( 5 kg ) , wall panelling with ply and mica pesting , finishingold / new wall with water proofing weathercoat smooth anti fungal premium textured exterior finish ofrequired shadeafter clering and clearing the surfaces etc.including scaffolding complete as directed at alllevels ( two coats ) . , b ) external electrification works , supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor / wall mounting compartmentalize panel board of size 0.95m x 1.30mx 0.40m made of 16 swg1.66 m thick c.r. sheet and40mm x 40mm x 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of red oxide metal primer and 2 coats of enamel paint. the panel board is to be erected in 1 : 3 : 6 pcc foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 400a 4pole mccb or switch fuse unit as incomer and provision for 4nos dp or tpn out going as specified and directed by the deptt. confirming to ip 43 protection comprising of the following electrical items: 1. 40mm x 5mm 4 strip copper bus bar 1.20 m length each i20mm x 3mm 4 strip copper bus bar 0.5m each 4 sets 2. digital 3 phase voltmeter accuracy class 0.5 1 no 3. digital 3 phase ammeter accuracy class 0.5 1 no 4. pilot lamp with integral ckt led 110 230 v ( red, yellow, & blue 3 no 5. voltmeter & ammeter selector switch 2 no 6. 2 a slide fuse unit 3nos ( incoming & outgoing switch gear of reqd. rating will be measured and paid separately ) , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt.. 3 & 1 / 2 core a2xfy 240.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from main distribution panel to machine panel , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 185.00 sq.mm.3 & 1 / 2 core armoured u.g. cable note:from panel to ups and ups to machine control panel , supply, installation & testing of copper plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. g.i. medium duty watering pipewith g.i. fittings such as socket, tee, elbow, nipple and 50 mmx40 mm g.i. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm c.i. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . note:for machine, chiller and ups. , extra for using salt ( 5 kand charcoal ( 96 kin g.i. / copper plate earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . , supply, fitting & fixing 20 mmx3 mm copper strips drawn on vertically or horizontally on building wall / parapet wall in surface system complete with supply of brassnuts & bolts, screws etc including riveting, soldering and making connection as approved by the deptt. ) with earth electrode copper strips and lightning arrestor etc. as specified and directed by the deptt. , supply and laying of following size pvc / xlpe insulated and pvc sheathed 1.1 kv gsolid aluminium conductor up to 10 sq mm balance stranded conductor, xlpe insulated, cores laid up, pvc tape inner sheathed, armour ( aluminium for single core up to 70 sq mm balance aluminium strip, galvanised for cables up to 2x10 sq mm.3x10 sq mm, 4x6 sq mm balance all galvanised steel strip ) , extruded pvc type st2 sheathed, 650 / 1100v grade as per is 7908 ( part 1 ) 1988 armoured u.g. cableu.g. cable laid in ground / partially in air ( as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. 3 & 1 / 2 core a2xfy 400.00 sq.mm.3 & 1 / 2 core armoured u.g. cable , c ) internal electrification works , wiring for circuit wiring with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface / recessedpvcconduit wiring system. with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for door interlock, fault ceiling light, laser, cctv, public adress system, ceiling fan, emergency switch , 2.7.1wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts pvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit note:for 6a and 16a power points , 2.7.2wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduitincluding earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. note: for air conditioner , wiring for drawing sub main line with p.v.c. insulated single core unsheathed industrial ( multistrand ) cable fr conforming to is 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voltspvc conduit including earth continuity in surface / recessed 20 mm. dia. 2mm thick / heavy isi marked is: 9537 part iii rigid pvc conduit wiring system. with 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick / heavy rigid pvc is: 9537 part iiiconduit. , sb. 8.28supplying with fitting fixing of 6 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including installation of socket outlet 6 / 16 amps 3 / 5 pin combine shuttered complete , including making necessary connection as per direction of department. , supplying with fitting fixing of 10 / 16 amp one way modular clip in switch, including making necessary connection as per direction of department. , supplying including and fixing of following moulded pvc boxes for in surface system complete as per direction of department. 8 module surface moulded pvc boxes. , supplying including fitting fixing of following front plate of suitable colour as per direction of department. 8 module , supplying including and fixing of following moulded pvc boxes in surface system complete as per direction of department. 12 module horizontal surface moulded pvc boxes , supplying including fitting fixing of followingfront plate of suitable colour as per direction of department. 12 module , supplying with installation testing and commissioning of hi wall 4 star rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection as approved by the deptt. ) up to 5 m between the room unit and out door unit as directed by the department. 2 ton capacity r410 , supplying with fitting and fixingvoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 5.0 kva automatic input 120 280 v out put 200 240 v , supplying with fitting and fixing of angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 ton to 2.00 ton window / split type a.c. machine , supplying with fitting and fixing of single phase modular a.c starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. , supplying including fitting fixing of followinga.c. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department [ without regulator ] . premium model1400 mm sweep. , supplying with fitting and fixing of 120 watt electronic modular step speed control 2 module type including making necessary connection as per direction of department. 120 watt electronic modular step speed control2 module type , supplying with fitting and fixing panel mounting open execution 35 / 36ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure ) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35 / 36 ka 415v 50 hz 3p mccb 400a , supplying with fitting and fixing panel mounting open execution 25 ka 415v 50hz 3p mccb ( ics=icu, adjustable ir setting 0.7 ) without enclosure of the following capacity complete with making necessary connection as approved by the deptt. as specified and directed by the deptt. 25 ka 415v 50 hz 3p mccb 125a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 100a , supplying with fitting and fixing 4p 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. c series 63a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.c series 6 to 32a , supplying with fitting and fixing single pole 10 ka 240 / 415v 50hz mcb of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.b series 6 to 32a , cc camera , public adress system , view box , supplying with fitting and fixing of 12watt, round led ceiling light with frame , supplying including fitting fixing of followinga.c. exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt. ) as required complete and as directed by the department. heavy duty 450 mm sweep 900 rpm single phase , d ) furniture works , suppying and installation of coloured tv 22 flat led wall mountingas directed by the department. , supplying fitting and fixing of furniture rack, table, store almirah, revolving chair etc. as required. , a ) computer chair ( 6 nos for control console & 6 nos. for tps room ) , b ) master table for use in computer in control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 10 x 3x2.5 ) ( 1 no for control console & 1 no. for tps room ) , c ) wall mounting manual shelf control room made of best quality water proof green ply 18mm thick finishing with sunmika size ( 6x2x16 ) , d ) shelf inside the labunkermade of best quality water proof green ply 18mm thick finishing with sunmika size ( 8 x 6x2 ) , e ) sypplying of decorative & comfortable 3 seater patient waiting chairmust be approved by the department. , cat ( b ) buy back items , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at actrec kharghar , buy back ( ie minus ) amount of old linear accelerator ( tomotherapy ) at tmh mumbai...

Central Railway - Maharashtra

31922848 supply of design, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points shoulddesign, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points should,design, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points should be class a as per en 54 20 covering the entire area of the coach. page 1 of 6 run date/time: 20/04/2022 15:26:45stores/central rly tender document , design, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no. rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: pass...

Western Railway - Maharashtra

31891379 supply of smoke detector unitsmoke detector unit,smoke detector unit with dual detector confirming to rcf specification edts 087, rev b. corr 1 or latest suitable for lhb eog coaches. ( material to be procured from approved sources only )...

Public Works Department - Maharashtra

31771659 providing replacement of existing damaged unrepairable wireless smoke detector, local control panel of wireless addressable fire alarm system at new administrative building, mumbai....

Dhule Municipal Corporation - Maharashtra

31700193 dhule / dmc / fd / usfs fund / 221 / 1 1 / 2021 22 installation of maharashtra fire safety campaign ( district level 2021 22 ) hydrant system, smoke detector, fire alarm, fire extinguisher etc. in the new administrative building of dhule municipal corporation installation of maharashtra fire safety campaign ( district level 2021 22 ) hydrant system, smoke detector, fire alarm, fire extinguisher etc. in the new administrative building of dhule municipal corporation for fire department....

Smart City Development Corporation Limited - Maharashtra

31613767 tender for sant tukaram natyagruh fire fighting works 1 supplying and erecting abc powder type fire extinguisher as per is : 13849 / 15683 of 6 kg capacity with necessary clamp for erection on wall. ( 10 2 36 ) 2 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 25 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 2 ) 3 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 50 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 3 ) 4 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 65 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 4 ) 5 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 75 / 80 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 5 ) 6 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 100 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 6 ) 7 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 150 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 7 ) 8 supplying and erecting g.i. pipe above ground of ‘c’ class erw of size 200 mm dia with necessary fittings complete as per specification no. ff pp ( 13 5 8 ) 9 providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. ( 13 5 10 ) 10 supplying and erecting cast iron foot valve ball type / flap type of size 100 mm dia with strainer for negative suction complete as per specification no. ff vl / fv ( 13 6 2 ) 11 supplying and erecting cast iron double flange sluice valve 160 mm dia. complete as per specification no. ff vl / sv ( 13 6 11 ) 12 supplying and erecting cast iron double flange butterfly valve of size 75 / 80 mm dia. complete as per specification no. ff vl / bfv ( 13 6 15 ) 13 supplying and erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. ff vl / bfv ( 13 6 16 ) 14 supplying and erecting cast iron double flange nrv of size 75 / 80 mm dia complete as per specification no. ff vl / nrv ( 13 6 19 ) 15 supplying and erecting cast iron double flange nrv of size 150 mm dia complete as per specification no. ff vl / nrv ( 13 6 21 ) 16 supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. ff vl / hv ( 13 6 31 ) 17 supplying and installingone piece moulded hdpe / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. ff ffa / pt ( 13 7 1 ) 18 supplying and installingwall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene ( polyhose ) fitted with necessary accessories complete as per specification no. ff ffa / hv ( 13 7 2 ) 19 supplying fire fighting controlled percolation ( c.p. ) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. ff ffa / cph ( 13 7 3 ) 20 supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. ff fa / fbc ( 13 7 10 ) 21 supplying and erecting fire brigade header ( siamese connection ) of 150 mm dia for supplying water to wet riser system complete as per specification no. ff ffa / smc ( 13 7 11 ) 22 supplying and installingair vessel of 300 mm dia 1.5m in height m.s. tank installed inside pump house / on terrace complete as per specification no. ff ffa / act ( 13 7 12 ) 23 supplying and installing pressure gauge of 100 mm dia., 0 300 psi or 0 14 kg per cm square fitted with 12 / 15 mm dia. pad cock valve, and g.i. pipe, elbow etc. complete as per specification no. ff ffa / pg ( 13 7 17 ) 24 supplying, installing, testing and commissioning ofoptical type smoke detector complete on box as per specification no. ff fas / sd ( 13 8 2 ) 25 supplying, installing, testing and commissioning four wire conventionally single ended reflected type beam smoke detector with 8 “ receiver . the range of smoke detector is max 164 feet. ( 13 8 3 ) 26 supplying, installing, testing and commissioning ofmanual call point ( pill box ) with break glass push button in metal enclosure complete as per specification no. ff faas / mcp ( 13 8 5 ) 27 supplying, installing, testing and commissioning ofhooters with crca enclosure complete as per specification no. ff faas / htr ( 13 8 6 ) 28 supplying, installing, testing and commissioning ofremote response indicators complete as per specification no. ff faas / rri ( 13 8 7 ) 29 supplying, installing, testing and commissioning offrls, xlpe armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall / ceiling complete as per specification no. cb lt / cu ( 13 8 8 ) ( note: 1 increase overall rate by 7.5% for frls. ) ( for fr xpe cable rate is 97 adding 7.5% as per note for frls ) 30 supplying, installing, testing and commissioning of4 zones microprocessor based conventional fire alarm control panel ( facp ) with standard accessories complete as per specification no. ff faas / facp ( note: increase overall rate by 25 % for additional zone as per requirement ) ( 13 8 12 ) ( for 2 zone panel rate is17588 adding 50% as per note for additional 2 zone will be 26382 ) 31 servicing of pump 32 maintenance of control panel 33 cleaning of tank 34 amc for 3 years ( as per scope of wok ) 1 ) inspection visit & maintenance of equipment: checking / testing / cleaning / oiling / greasing of all components related to fire safety equipment, including fire alarm system , hydrant delivery valve, hose reel with drum, gate valve, fire pump and response indicators ( r.i ) , sprinkler system, etc 2 ) consumable items of fire and electrical equipment are to be replaced as and when required. 3 ) cleaning and painting: basic cleaning and polishing of every gun metal make vital outlet, i.e., adaptor hydrant valve, branch pipe, fcb, extinguishers etc. and cleaning of smoke detector by blower.4 ) maintenance of fire fighting system etc.: overall responsibility of maintenance of fire fighting system, fire pumps including periodic overhauling, oiling, and greasing, preventing maintenance of sprinkler system leakage, attending to sprinklers as and when necessary. detection and attending to leakages if any within the system. fire fighting system attendance ( electrical parts ) . regular checks and drills as per safety norms. 5 ) renewal of fire noc: liasioning with wbf&es for getting fire noc, when itfalls due for renewal6 ) checking / testing / repairing / : repairing of water pipe line related to the firefighting system7 ) mock fire drill & training program to be conducted with prior notice to nsic....

Public Works Department - Maharashtra

31472031 est.no.sdr 11p03 09 2021 22 of providing replacement of existing damaged unrepairable wireless smoke detector, local control panel of wireless addressable fire alarm system at new administrative building, mumbai....

Central Railway - Maharashtra

31065218 supply of design, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points shoulddesign, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points should,design, supply, installation, commissioning and maintenance of aspiration type automatic smoke/ fire detection with alarm system for indian railway ac coaches as per rdso specification no.rdso/2008/cg 04 rev. 05 as per amended item no. 3.2.1 of scope of work (page 5 of 29, of rdso spec. no. rdso/2008/cg 04 rev.05) which is to be read as follows: passenger coaches: aspiration smoke detectors in passenger area, doorway area, electrical cabinet area and lavatory area. sampling points should be class a as per en 54 20 covering the entire area of the coach. coach assly. shop /pr , maharashtra 600.00 set...

Dr. Babasaheb Ambedkar Marathwada University - Maharashtra

31024096 amc repairing and maintenance for fire alarm system amc repairing and maintenance for fire alarm system , fire alarm system annual maintenance contractwith all accessories smoke detector/ heat detector/ manual call point/ hooters/fire alarm control panel for auditorium (56 smoke detector and 12 zone fire alarm system ) , fire alarm system annual maintenance contractwith all accessories smoke detector/ heat detector/ manual call point/ hooters/fire alarm control panel forcentral facility center (51 smoke detector and 16 zone fire alarm system) , supplying and erecting hooters , supplying and erecting smoke detector , supplying and erecting batteries for above system...

Indian Army - Maharashtra

31002351 bids are invited for job work required for repair replacement of unsv defective apfc lt panel and connected items at sub station no. at site p af stn thane under ge (af) thane , job work required for repair replacementof unsv defective smoke detector and controlpanel at mts & logistic sec at site p af stn thaneunder ge (af) thane total quantity : 2...

Military Engineer Services - Maharashtra

30860666 provision of otm accn for mdc kamptee lump sum price worked out by the contractor for building work as listed in schedule ‘a’part i ( ref prepriced schedule attached seperately ) 4 lump sum price worked out by the contractor for internal water supplyas listed in schedule ‘a’part ii ( ref prepriced schedule attached seperately ) 5 lump sum price worked out by the contractor for internal electrification as listed in schedule ‘a’part iii ( ref prepriced schedule attached seperately ) 6 lump sum price worked out by the contractor for external water supply as listed in schedule ‘a’part iv ( ref prepriced schedule attached seperately ) 7 lump sum price worked out by the contractor for external eletric supply as listed in schedule ‘a’part v ( ref prepriced schedule attached seperately ) 8 lump sum price worked out by the contractor for road, path & culvert as listed in schedule ‘a’part vi ( ref prepriced schedule attached seperately ) 9 lump sum price worked out by the contractor for area drainage as listed in schedule ‘a’part vii ( ref prepriced schedule attached seperately ) 10 lump sum price worked out by the contractor for sewage disposal as listed in schedule ‘a’part viii ( ref prepriced schedule attached seperately ) 11 lump sum price worked out by the contractor for security fencing and gate as listed in schedule ‘a’part ix ( ref prepriced schedule attached seperately ) 12 lump sum price worked out by the contractor for fire alarm system as listed in schedule ‘a’part x ( ref prepriced schedule attached seperately ) 13 lump sum price worked out by the contractor for air conditioning, cooling appliances & water heater as listed in schedule ‘a’part xi ( ref prepriced schedule attached seperately ) 14 lump sum price worked out by the contractor for lightning protection as listed in schedule ‘a’part xii ( ref prepriced schedule attached seperately ) 15 lump sum price worked out by the contractor for dg set as listed in schedule ‘a’part xiii ( ref prepriced schedule attached seperately ) 16 lump sum price worked out by the contractor for exacavation, earth work & site development as listed in schedule ‘a’part xiv ( ref prepriced schedule attached seperately ) 17 sch a pt xv ( miscellaneous items ) 18 internalwater supply note: for items of internal water supply notes given at the beginning of sch ‘a’ part ii shall also be applicable. 19 s&f 2 in 1 angle cock cum bib tap with flange, 15mm bore dia, cast copper alloy, chromiuim plated, fancy type , screwwed down, high pressure, with crutch, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 20 s&f 15mm bore cp urinal spreader for urinals and fixed in position complete all as specified and directed. 21 internal eletrification note: for items of internal electrifications notes given at the beginning of sch ‘a’ part iii shall also be applicable. 22 m&l for point wiring using approved colour coding as per is ( red, black and green for single phase circuits ) , with multi stranded copper conductor1.5 sq. mm nominal cross sectional area, single core, pvc insulated and unsheathedfrls cable 1100 volts grade, isi 694 marked with valid cml no., drawnin and including medium grade, rigid pvc concealed conduit and conduit accessories concealed in wall / roof / floor etc, isi marked with valid cml no. ( is 9537 1983 for conduits and is:3419:1976 for conduit accessories ) , in mild steel / pressed steel sunken boxes ( with earth dolly ) with and including of 03mm thick bakelite, laminated hylem sheet top cover of suitable size for fixing of switches, sockets and fan regulators etc, including pvc insulated multi stranded copper conductor 1.5 sq mm nominal cross sectional area single core frlscable as earth continuity conductor to common earth and connecting to earth dollycomplete all as specified and directed for the following: 23 one light point point controlled by one 5 / 6 amps one way modular switch. 24 one ceiling / exhaust fan point controlled by one modular switch and regulator. 25 one bell / buzzer point controlled by one modular bell push. 26 one light point controlled by two5 / 6 amps two way modular switchs. 27 one socket outlet, three / five pin, 5 amp, controlled byone 5 / 6 amps one way modular switch or modular switch / socket combination 5 amps, 5 pin on the same board with other switches, sockets, fan regulators, etc. 28 one socket outlet, three / five pin, 5 amp, controlled byone 5 / 6 amps one way modular switch or modular switch / socket combination 5 amps, 5 pin on independent board. 29 m&l for point wiring using approved colour coding as per is ( red, black and green for single phase circuits ) , with multi stranded copper frlsconductor2.5 sq. mm nominal cross sectional area, single core, pvc insulated and unsheathedcable 1100 volts grade, isi 694 marked with valid cml no., drawn in and including medium grade, pvc concealed conduit and conduit accessories concealed in wall / roof / floor etc, isi marked with valid cml no. ( is 9537 1983 for conduits and is:3419:1976 for conduit accessories ) with and including ms / pressed steel sunken box ( with earth dolly ) with and including 3mm bakelite, laminated hylem sheet top cover of suitable size, including pvc insulated multi stranded copper conductor 2.5 sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dollycomplete all as specified and directed at site for the one 3 / 5 pin amps 15 / 16 amp socket outlet independent complete all as specified and directed. 30 s&f led lamp 9 / 10 w, pin type b 22, 230v ac, 50hz single phase including bakelite batton holder with all fitting fixing accessories complete all as specified and directed.notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 31 s&f led tube light fitting 20 w, 230v made of aluminium housingand integrated electronic drivercomplete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 32 s&f led tube light fitting 18 w, 230v made of aluminium housingand integrated electronic drivercomplete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 33 s&f flat panel 2 x 2 surface mounting 36w led luminiar for glare free symmetric soft light with high brightness smd leds and min 4150 lumenscomplete with all accessories including driver pre wired complete all as specified and directed.notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 34 s&f flat panel 2 x 2, recess mountingled luminaire power consumption not more then 36w, system lumens output 4250 or above, cct5700k, suitable for armstrong / grid ceiling with high brightness smd leds complete with all accessories including driver pre wired complete all as specified and directed.notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 35 s&f led 10w bulkhead light fitting with all accessories including driver pre wired complete with all fittings all as specified and directed. notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 36 s&f in replacement vtpn, 8 way, distribution board, double door, vertical type including fixing and connecting of mccbs / mcbs / isolator / elcbs, etc factory made, confirming to is: 13032 fabricated out of crca sheet not less than 1.2 mm thick fitted with din channel, neutral link and 200 amps 440 volts rated bus bar. db shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, between powder painting process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosive atmosphere. the db shall be double door type with hinged door with locking arrangement. the db shall be of same make as mcbs / isolator. db shall also be provided with label marking indicating the incoming and outgoing circuits. the db shall be of ip 43 protection class complete all as specified and as directed. note: mccbs / mcbs shall be measured and paid seperatly. 37 s&fled street light fitting, minimum capacity of25w, made up of pressure die cast aluminium housing with high efficency led as lighting source and lens with toughned glass having bottom seperate driver compartment with ip 66 protection and impact resistance of ik 07, etc and all accessories prewired with & including mounting bracket of 40mm bore light grade pipe of required length and shape including bending, forging or welding, etc and suitable bolts, nuts, washeres, etc and connecting with pvc insulated multi stranded copper flexible cable of size 0.5 sqmm, three core from ceiling rose to fitting complete all as specified and directed. notes: 1. warranty for replacement of each led shall not be less than 05 yearsfrom the date of purchase.2. date of purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. 38 s&f mcb spn, 40 amp, 240 volts ac confirming to is: 13947 3 and iec 60898 c curve type, breaking capacity 10 ka complete all as specified and directed. [ qty = 12 ( int wiring ) + 1 ( fire alarm ) ] 39 s&f mcb spn, 6 to 32 amp, 240 volts ac confirming to is: 13947 3 and iec 60898 c curve type, breaking capacity 10 ka complete all as specified and directed. 40 s&f mcb sp, 6 to 32 amp, 240 volts ac confirming to is: 13947 3 and iec 60898 b curve type, breaking capacity 10 ka complete all as specified and directed. [ qty = 106 ( int wiring ) + 4 ( fire alarm ) ] 41 s&f mcb sp, 40 amp, 240 volts ac confirming to is: 13947 3 and iec 60898 b curve type, breaking capacity 10 ka complete all as specified and directed. 42 m&l for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 metre deep below ground level ) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate no 3 of mes ssr 2009 part i connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade gi pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, pcc pit with pre cast rcc cover with handle of 8 mm dia bar, charcoal / salt, funnel with wire mesh etc complete all as specified and directed.note : ( i ) the concrete pit ( to be provided atleast 500mm away from earth pit ) shall be pcc ( 1:3:6 ) type c 1, 40 mm thick pre cast cover slab of rcc ( 1:2:4 ) type b 1 using 20mm graded stone aggregate reinforced with 8mm tmt bars @ 10 cm c / c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate no 3 of mes ssr part i. ( ii ) the unit rate includes the cost of gi pipe light grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 m. 43 s&f telephone rj 11 socket, modular type, 1 module with & including ms / pvc concealled flush boxcomplete all as specified and as directed. 44 s&f lan rj45 socket, modular type, 1 module with & including ms / pvc concealled flush boxcomplete all as specified and as directed. 45 m&l for 32 mm dia pvc conduit and conduit accessories, concealed in walls complete all as specified and directed 46 external water supplynote: for items of external water supply notes given at the beginning of sch ‘a’ part iv shall also be applicable. 47 m&l forconstruction of brick masonary new valve pit chamber of following size 100mm thick pcc 1:4:8 type d2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in cm 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin cm 1:4and finished fair and even supply and fix 3.15 mm thick ms sheet steel cover fixed on 50mmx50mmx6mm thick angle ironframe embbeded in pcc copingwith locking arrangement and 1 nos 50mm size 4 levers lock with key in duplicate standard size and ms hold fast and handle made out of 25 x 6mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer ( red oxide ) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. 48 900 mm x 900 mm x 900 mm size 49 external electric supplynote: for items of external electric supply notes given at the beginning of sch ‘a’ part v shall also be applicable. 50 m&l for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 metre deep below ground level ) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate no 3 of mes ssr 2009 part i connected to test point or main switch board or main control board all as specified and testing on completion including provision of earth strip protection by 40mm dia light grade gi pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, pcc pit with pre cast rcc cover with handle of 8 mm dia bar, charcoal / salt, funnel with wire mesh etc complete all as specified and directed.note : [ qty = 2 ( ext electric ) + 4 ( dg set ) =6 ] ( i ) the concrete pit ( to be provided atleast 500mm away from earth pit ) shall be pcc ( 1:3:6 ) type c 1, 40 mm thick pre cast cover slab of rcc ( 1:2:4 ) type b 1 using 20mm graded stone aggregate reinforced with 8mm tmt bars @ 10 cm c / c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate no 3 of mes ssr part i. ( ii ) the unit rate includes the cost of 40mm gi pipe light grade for protection of earth strip and 32 x 6 mm gi earth strip upto 7.5 m. 51 s&f 120mm outer dia & 108mm inner dia double wall corrugated high density polymer ethyl ( hdpe ) pipe with is 14930 ( part 2 ) 2001 and 6mm wall thickness; for laying of electric cable; laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. [ qty = 75 ( ext electric ) + 70 ( dg set ) =145 ] 52 s&f 90mm outer dia & 78mm inner dia double wall corrugated high density polymer ethyl ( hdpe ) pipe with is 14930 ( part 2 ) 2001 and 6mm wall thickness; for laying of electric cable; laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. 53 s&f 50mm outer dia & 38mm inner dia double wall corrugated high density polymer ethyl ( hdpe ) pipe with is 14930 ( part 2 ) 2001 and 6mm wall thickness; for laying of electric cable; laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. 54 design, supplying, installing, testing and commissioning ltpower distribution feeder pillar panel board, outdoor, double door ip 65 type factory fabricated cubicaltype weather vermin proof with locking arrangement and made out of ms crca sheet 3.15 mm thick suitable size of channel for base complete with 4 nos 400 amps rated aluminium bus bar inside sepreate chamberand compartmentalised cabinet for housing andmounting mccbs, metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixing an angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming &alloutgoing controls and comprising with the following : 55 item no. 6.05 contd.......incoming: ( a ) bus bar chamber comprising 4 nos aluminium strip bus bars air insulated and pvc sheathed capacity 400 amps with colour coding in separate sheet steel enclosure. ( i ) mccb 4 pole 200 amps 415 volts 36 ka 01 no. ( thermal setting adjustable type 80 100% ( ics 100% icu ) with connection terminals. outgoing: ( b ) mccb 4 pole, 100 amps 415 volts 25 ka 02 nos. ( thermal setting adjustable type 80 100% ( ics 100% icu ) with connection terminals ( c ) mccb 4 pole, 63 amps 415 volts 25 ka 02 nos. ( thermal setting adjustable type 80 100% ( ics 100% icu ) with connection terminals ( d ) mccb 4 pole, 40 amps 415 volts 10 ka 02 nos. ( thermal setting adjustable type 80 100% ( ics 100% icu ) with connection terminals ( e ) multi function meter 01 no ( f ) phase indicating led lamps ( r y b ) 01 set ( g ) internal wiring with single core copper conductor cable / pvc insulated copper strip of suitable size incoming to bus bar and bus bar to outgoing mccb / mcb 01 job. ( h ) fine wiring with single core copper conductor cable for instruments / indicating lamps 1 job. ( j ) platform for the feeder pillar board with pcc 1:2:4 15 cm thick in foundation, brick ( sub class b ) / stone / pcc blockwork incm 1:6 , rendering 1:6 on exposed surfaces and 100 mm thick pcc 1:3:6 type c1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . the platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements. 56 s&f led bollard fitting, inverted pyramid tripod with soft 360 degree lihgt and ip 65 protection including drivers, with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size of 230v 50hz from fitting to junction box with & including necessary ppc work type b 1 for fixing of bollard and formwork complete all as specified and directed. 57 s&f street light brackets made out of gi tubing, light grade, 40 mm bore 1500mm long, bent to shape at 120 degree, fixed on pole by providing 2 nos ms clamp made up of flat iron 30 x 5 mm including bolts, nuts and washer of suitable size incuding painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed. 58 s&f thermoplastic cable junction bos, ip 55 / ip 65 with metric knockout for cable entry of size 200 x 160 x 98mm fixing on pole with 30 x 5mm ms clamps, nuts, bolts, washers, terminal block and glands suitable for 16 sqmm core cable with & including 1 no. 6 amps mcb spn 10kacomplete all as specified and directed. 59 road, path & culvertnote: for items of road, path & culvertnotes given at the beginning of sch ‘a’ part vi shall also be applicable. 60 m&l for road line painting 100mm wide with golden yellow / white thermostatic compound with reflectorised glass beads on bituminous road, providing and laying of hot applied thermostatic compound 2.5mm thick including glass beads @ 250gm per sqm area thickness 2.5mm is exclusive of surface applied, glass beads as per irc 35. the finish surface to be level and uniform and free from streaks and holes in addition where arrows or letter to be provided thermoplastic compound may be hard spalayed. the colour of compound shall be as directed complete all as specified and directed. 61 s&f solar road studs of size 125mm x 125mm x 20mm, aluminium alloy and polycarbonate stud ( red / yellow leds ) 3+3 leds with shank in tough aluminium die cast body with ms zinc coated nails of size 12mm dia and 120mm long complete as per morth / irc specifications and directed. 62 sewage disposal note: for items of dewage disposal notes given at the beginning of sch ‘a’ part viii shall also be applicable. 63 m&l for brick masonry septic tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, pcc ( 1:4:8 ) below foundation, base slab, buffle walls and precast cover slab etc with vent shaft, inspection chamber etc all as specified and shown in drawing no. cebz / td / 76 / 2011 sheet 1 / 2 & 2 / 2complete all as specified and directed. 64 m&l for site soakage well of 1.8m dia and 3meffective depth; excavation in any type of soil, foundation in pcc 1:3:6, wall of honey combed and solid including intercepting chamber, screen chamber brick work in cm, rcc cover slab / rr masonry / filling with brick bats all as specified and shown in drawing no. cebz / td / 78 / 2011 sheet 1 / 2 & 2 / 2 complete all as specified and directed. 65 fire alarm systemnote: for items of fire alarm systemnotes given at the beginning of sch ‘a’ part x shall also be applicable. 66 supply, installation, testing and commissioning of conventional photo electric smoke detectors including base plate, mounting accessories complete all as specified and directed. 67 supply, installation, testing and commissioning of manual call point wall recess / surface mounting, dust & vermin proof, intelligent type, with &including additional modules, mounting accessories and ms painted outlet box for fixing of the station complete all as specified and directed. 68 supply, installation, testing and commissioning of fire alarm hooter, wall / ceiling recessed high intensity multi tone sounders of intensity as mentioned in the specification including ms outlet box for fixing of the sounder, mounting accessories complete all as specified and directed. 69 supply, installation, testing and commissioning of 12 zone fire alarm panel, wall / surfcae mounted, conventional fire control panel, 240v, ac power supply including automatic battery charger, 24 volts sealed batteries sufficient for 48 hours normal working and be capable of operating the system for 30 minutes during emergency conditions, as required complete all as specified and directed. 70 supply, installation, testing and commissioning of 12 volts, 7 ah battery for fire alarm panelcomplete all as specified and directed. 71 air conditioning, cooling applinaces & water heaternote: for items of air conditioning, cooling applinaces & water heaterl notes given at the beginning of sch ‘a’ part xi shall also be applicable. 72 s&f single pole and neutral enclosure with two pin and earth plug and socket complete with & including one single pole mcb 20 amp 240v rupturing capacity 10ka c series complete all as specified and directed. 73 s&f 5 kva capacity voltage stabliser for automatic operation, single phase, air colled, indoor wall mounted type and designed for input variation between 170 volts to 250 volts, otput stablise between 230 volts with accuracy of + 2.5% complete all as specified and directed. 74 s&f 3kva capacity voltage stabliser for automatic operation, single phase, air colled, indoor wall mounted type and designed for input variation between 170 volts to 250 volts, otput stablise between 230 volts with accuracy of + 2.5% complete all as specified and directed. 75 supply & installed refrigerator, electric driven ( single phase ) 230 volts, single phase, 50 hz, bee certified minimum 4 star rating, capacity not less than 195 litres, frost free complete all as specified and directed. 76 lightning protectionnote: for items of lightning protection notes given at the beginning of sch ‘a’ part xii shall also be applicable. 77 m&l for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with copper earth strip 32 x 6mm all as shown inplate no. 2 to the earthing test point or main switch board or main control board all as specified and testing on completion including provision of earth strip protection by 40mm dia light grade gi pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, pcc pit with pre cast rcc cover with handle of 8 mm dia bar, charcoal / salt, funnel with wire mesh etc complete all as specified and directed.note : ( i ) the concrete pit ( to be provided atleast 500mm away from earth pit ) shall be pcc ( 1:3:6 ) type c 1, 40 mm thick pre cast cover slab of rcc ( 1:2:4 ) type b 1 using 20mm graded stone aggregate reinforced with 8mm tmt bars @ 10 cm c / c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate no 3 of mes ssr part i. ( ii ) the unit rate includes the cost of 40mm gi pipe light grade for protection of earth strip and 32 x 6 mm copperearth strip upto 7.5 m. 78 dg setnote: for items of dg set notes given at the beginning of sch ‘a’ part xiii shall also be applicable. 79 supply, installation testing and commissioning of oem manufactured, static silent ( sound proof enclosure ) , disel engine driven generating set capable of delivering 62.5 kva, water cooled, 415 volts ( ac, 3 phase, 4 wire system of supply ) 50 hz at power factor 0.8 minium. the dg set shall consists of diesel engine coupled to a matching alternator through flexible coupling and mounted on common base frame with control panel standaedised by manufacturer, fuel tank with mounting arrangements and inlet outlet return inlet oil arrangemnet, exhaust pipe complete and suitable for conditions prevelant at kamptee ( nagpur ) including pcc foundation of suitable size ( leaving atleast 0.5m all round space for easy of movement and 0.5m height ) anti vibration pads, including all features with latest cpcb guidelines and comprising of following complete all as specified and directed: 80 item no. 12.01 contd / ( i ) engine ( prime mover ) : diesel engine 1500 rpm, direct injection, type four stroke, confirming to iso 3046 / bs 5514, water cooled, naturally turbo charged, capable of giving notless than 83 bhp to drive alternator capable of delivering 62.5 kva at outdoor atmospheric conditions at kamptee ( nagpur ) , ( taking all derating factor into consideration ) , 12 volt ( as permanufacturer recommendations ) electric battery start, complete with fly wheel all standardwithfittings / fixtures as per manufacturer and including suitable panel with tachometer, lubtemperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor ( ecpg ) and engine protection system ( shut down, high water temperature, low lub oil, oil pressure, over speed etc ) fuel tank and first fill of lub oil and other consumables etc. ( ii ) alternator :brushless ac alternator, 3 phase, 415 volt , 4 wire, rated to drive 83kva, minimum power factor 0.8, 15000 rpm, ip 23 protection class enclosure, insulation class “h” salient pole, revolving field singlebearing automatic voltage regulator coupledthroughflexible coupling with and to match the above engine.note: alternator capacity calculated as per ambient temperature 50 degree centigrade of nagpur area. ( iii ) base plate : made out of structural steel as per manufactures recommended design / specifications. ( iv ) in built amf control panal : factory made, cubical type, in built amf panel borad, indoor type made out of ms angle not less than 25 x 25 x 5 mm and 2 mm thick ms crca sheet, front opening type, protection class ip 54, duly powder coated after seven tank process, withelectrolytic grade copper bus bar of 100 amps capacity for four poles, with all standardswitchgear and protection, internal wiring of adequate size pvc insulated multistranded copperconductor cable etc and also consisting of following : ( a ) mccb, 100 amp, 415 volts rating, 4 pole, 25 ka rupturing capacity, specially fixed for incoming supply with over load relay, short circuit and fault protection – 01 no with suitable rating hrc back up fuses. ( b ) amf logic panel including wiring, power contractor with mccb suitable capacity for dg set of main supply, single phase preventor, digital multifunction meter ( showing amps, volts, hz, kwh etc. ) emergency stop button, dgset over load, high water temp, low lub oil pressure, auto charging unit and failure to start, phase indication lamp led type ryb including all relays, circuit and protection required for automatic operation of dg set. ( v ) accousticenclosure :sheet metal fabricated cope type, silent enclosure, manufactured on cnc machines as per cpcb norms and powder coated after seven tank process; the enclosure shall be designed for reducing the sound level to 75 db ( a ) at a distanceof 1 m at 75% load under field condition and ox, 70 db at 3 m from gen set when dg set is working at full load alongwith testing conformance, lebelling certification etc as laid down in gsr no. 371 ( e ) dt 17 may 2002. ( vi ) foundation / plinth / base : shallbe provided as per manufacturers recommendations with atleast 0.5m all round space for easy of movement and 0.5m height ( minimum ) . ( vii ) diesel storage tank : shall be as per manufacturers specifications. ( viii ) misc: toolkit, operation & maintenance catalogue, spare part list, overhauling manuals, gurantee card, etc shall be provided as per manufacturers standard practices without any extra cost to the department. 81 special items 82 s&f hospital name board military dental centre kamptee and in / out in stainless steel letters with illumination ( 20 cm height of each letter ) withss channel edacrylic letters; back sunboard channel letter, 3mm acrylic sheetub a cast, laser cutting and solid letter 10 with 3 m vinyl pasting; water proof, wind proof and capable of withstanding harsh climatic conditions complete all as specified and directed. 83 s&f modular cabinet with granite counter top, lacquer treated mdf door, drawer with handles / knobs, etc complete all as specified and directed. 84 s&f 30mm thick first class hardwood folding partitions with durable finish, study design with necessary treatments, etc complete all as specified and directed. 85 s&f polyster blend zebra blinds for windows as approved by ge complete all as specified and directed. 86 s&f 25mm high density polythelene pipes of pressure rating 6kg / sq cm laid on walls, in trenches, etc complete all as specified and directed....

Hindustan Petroleum Corporation Limited - Maharashtra

30828374 so for cctv mcp maint services towards checking of m long description: scope of mcp, smoke detector and fire alarm system status from field panel to dcs and fire station:in hpcl mr mcp and fire alarm systems and smoke detectors are available as emergency response system. for uninterrupted emergency response vendor is required to work on these jobs on daily basis. a. vendor personnel shall be available in refinery in all working days between 0800 hrs to 1630 hrs.b. vendor shall depute man power to attend emergencies in sat/sun and holidays if asked by concerned hpcl supervisor.c. vendor person shall maintain healthiness of communication system status from mcp to fire station and smoke detector.d. vendor shall check communication status of each smoke detector system, mcp and fire alarm system everyday and report.e. vendor shall troubleshoot the failure and assist in resolution.f. vendor person shall maintain healthiness of fire alarm system and mcp communication status from field panel to dcs and fire station.activities in vendor scope:1) inspection/checking/repairs of smoke detectors and manual call points installed at various places in hpcl, mr as per the asset list provided.2) carry out monthly response checking(functional testing) of detectors/mcps as per pm (preventive maintenance) schedule functional testing shall be carried out in presence of fire and safety dept. of hpcl, mr and contractor to obtain endorsement of the same from f&s team. all mcps to be response checked once in a quarter and smoke detectors to be checked once in a year ( i.e. 1/4 of total in each quarter)3) carry out physical inspection of all components including their mounting, cabling, etc and coordinate with those agencies to ensure that the jobs are done as per standard practices.4)the vendor shall arrange to provide services from respective oems of various systems in case they are unable to resolve problems on their own. oem service engineer charges shall be paid separately as per relevant line items.5) the scope of job also includes replacements of faulty smoke detectors and mcps.6) contractor must be available for the trouble shooting of the above mentioned fire alarm system within 24 hours of intimation, services towards checking of c long description: services for maintenance of cctv surveillance system maintenance and trouble shooting at hpcl , mr.i. daily communication, interaction and co ordination between various internal departments at the mumbai refinery, viz cisf, hr, maintenance and it as well as external entities like the oems of the cctv system.ii. daily monitoring of the health of the cctv system and its components.iii. identification of problems in the control room as well as in the field.iv. fully conversant with the layout of the plant area to ensure quick and effective response to any incident or break down.v. provide the initial first response quickly to any alarm or trigger and its subsequent escalation to the designated hpcl authorities.vi. provide the initial first response quickly to any break down of any component of the cctv system whether in the control room, datacentre or field and subsequently follow it up until resolution.vii. attending to the identified problems and resolving the same in co ordination with the cctv oems and various departments of m/s hpcl.ix. monitor and maintain logs and provide the same to the designated hpcl authorities on a regular basis.x. respond and report to the designated hpcl authorities any incidents, events and security breaches with respect to the cctv system.xi. full awareness in concurrence with the hpcl personnel about the current and potential security threats with respect to the cctv system.xii. contractor shall maintain an attendance register. the attendance register shall be daily endorsed by concerned hpcl engineer. this shall be attached along with invoice/ delivery challan along with service report for billing purpose.xiii.familiarity with indigo vision software, and experience on video servers.xiv. basic networking knowledge required which includes using lan tester, fo tester, network switches fault finding and fo/lan trouble shooting.xv. co ordination with other departments like electrical, it/is, cisf, hr for various job related tasks.xvi. experience to work on 230 vac as some cameras are on 230 vac.hpcl scope:============a) any technical deviation/ clarification shall be sorted out with the concerned contact personnel mentioned below.b) issue of hot/height/cold permits, material gate pass.c) supply of materials like spares of cctv systems, mounting brackets, stands , camera and networking accessories.d) pc/laptop/tools/tackles/internet/seating arrangements etc., required for the carrying out the activities will be provided by m/s hpcl free of cost.e) hpcl will arrange for manpower ( workers: electrician, fitter , welder , helper etc) for heavy jobs like support installation, camera removal, installation, scaffolding etc. however the job shall be carried out in supervision of contractors supe, services towards monitoring an long description: scope of supply for cems and cams communication related jobsambient and stack analyzer readings are being sent to cpcb server using various methods of communication such as rs232, rs485 modbus and analog signal to tcp/ip. communication is established between field stacks and ambient analyzers and data is posted over hpcl network through nearest it racks primarily in cems stations.in hpcl mr 129 stack and 24 ambient analyzers data is sent to cpcb servers. remote calibration of cems parameters from cpcb server is already in place. data availability is to be monitored by vendor. these analyzers are installed over vast area over hpcl lan with variety of hardware and network interfaces, it is required to work on these jobs on daily basis.a. vendor persons shall be available in refinery in all working days between 0800 hrs to 1630 hrs.b. vendor shall depute man power to attend emergencies in sat/sun and holidays if asked by concerned hpcl supervisor.c. vendor person shall maintain healthiness of communication system status from analyzers to network switchd. vendor shall check communication status of each stack everyday and report.e. vendor shall troubleshoot the failure and assist in resolution...

Hindustan Petroleum Corporation Limited - Maharashtra

30804644 so for cctv mcp maint services towards checking of m long description: scope of mcp, smoke detector and fire alarm system status from field panel to dcs and fire station:in hpcl mr mcp and fire alarm systems and smoke detectors are available as emergency response system. for uninterrupted emergency response vendor is required to work on these jobs on daily basis. a. vendor personnel shall be available in refinery in all working days between 0800 hrs to 1630 hrs.b. vendor shall depute man power to attend emergencies in sat/sun and holidays if asked by concerned hpcl supervisor.c. vendor person shall maintain healthiness of communication system status from mcp to fire station and smoke detector.d. vendor shall check communication status of each smoke detector system, mcp and fire alarm system everyday and report.e. vendor shall troubleshoot the failure and assist in resolution.f. vendor person shall maintain healthiness of fire alarm system and mcp communication status from field panel to dcs and fire station.activities in vendor scope:1) inspection/checking/repairs of smoke detectors and manual call points installed at various places in hpcl, mr as per the asset list provided.2) carry out monthly response checking(functional testing) of detectors/mcps as per pm (preventive maintenance) schedule functional testing shall be carried out in presence of fire and safety dept. of hpcl, mr and contractor to obtain endorsement of the same from f&s team. all mcps to be response checked once in a quarter and smoke detectors to be checked once in a year ( i.e. 1/4 of total in each quarter)3) carry out physical inspection of all components including their mounting, cabling, etc and coordinate with those agencies to ensure that the jobs are done as per standard practices.4)the vendor shall arrange to provide services from respective oems of various systems in case they are unable to resolve problems on their own. oem service engineer charges shall be paid separately as per relevant line items.5) the scope of job also includes replacements of faulty smoke detectors and mcps.6) contractor must be available for the trouble shooting of the above mentioned fire alarm system within 24 hours of intimation, services towards checking of c long description: services for maintenance of cctv surveillance system maintenance and trouble shooting at hpcl , mr.i. daily communication, interaction and co ordination between various internal departments at the mumbai refinery, viz cisf, hr, maintenance and it as well as external entities like the oems of the cctv system.ii. daily monitoring of the health of the cctv system and its components.iii. identification of problems in the control room as well as in the field.iv. fully conversant with the layout of the plant area to ensure quick and effective response to any incident or break down.v. provide the initial first response quickly to any alarm or trigger and its subsequent escalation to the designated hpcl authorities.vi. provide the initial first response quickly to any break down of any component of the cctv system whether in the control room, datacentre or field and subsequently follow it up until resolution.vii. attending to the identified problems and resolving the same in co ordination with the cctv oems and various departments of m/s hpcl.ix. monitor and maintain logs and provide the same to the designated hpcl authorities on a regular basis.x. respond and report to the designated hpcl authorities any incidents, events and security breaches with respect to the cctv system.xi. full awareness in concurrence with the hpcl personnel about the current and potential security threats with respect to the cctv system.xii. contractor shall maintain an attendance register. the attendance register shall be daily endorsed by concerned hpcl engineer. this shall be attached along with invoice/ delivery challan along with service report for billing purpose.xiii.familiarity with indigo vision software, and experience on video servers.xiv. basic networking knowledge required which includes using lan tester, fo tester, network switches fault finding and fo/lan trouble shooting.xv. co ordination with other departments like electrical, it/is, cisf, hr for various job related tasks.xvi. experience to work on 230 vac as some cameras are on 230 vac.hpcl scope:============a) any technical deviation/ clarification shall be sorted out with the concerned contact personnel mentioned below.b) issue of hot/height/cold permits, material gate pass.c) supply of materials like spares of cctv systems, mounting brackets, stands , camera and networking accessories.d) pc/laptop/tools/tackles/internet/seating arrangements etc., required for the carrying out the activities will be provided by m/s hpcl free of cost.e) hpcl will arrange for manpower ( workers: electrician, fitter , welder , helper etc) for heavy jobs like support installation, camera removal, installation, scaffolding etc. however the job shall be carried out in supervision of contractors supervisor., services towards monitoring an long description: scope of supply for cems and cams communication related jobsambient and stack analyzer readings are being sent to cpcb server using various methods of communication such as rs232, rs485 modbus and analog signal to tcp/ip. communication is established between field stacks and ambient analyzers and data is posted over hpcl network through nearest it racks primarily in cems stations.in hpcl mr 129 stack and 24 ambient analyzers data is sent to cpcb servers. remote calibration of cems parameters from cpcb server is already in place. data availability is to be monitored by vendor. these analyzers are installed over vast area over hpcl lan with variety of hardware and network interfaces, it is required to work on these jobs on daily basis.a. vendor persons shall be available in refinery in all working days between 0800 hrs to 1630 hrs.b. vendor shall depute man power to attend emergencies in sat/sun and holidays if asked by concerned hpcl supervisor.c. vendor person shall maintain healthiness of communication system status from analyzers to network switchd. vendor shall check communication status of each stack everyday and report.e. vendor shall troubleshoot the failure and assist in resolution...

Central Railway - Maharashtra

30785470 supply of safety leaflets and stickerssafety leaflets and stickers,set of stickers and safety leaflet consisting following items: 1) no smoking stickers qty. 1500 nos. 2) smoke detector stickers qty. 1500 nos. 3) bio toilet stickers qty. 2000 nos. 4) safety leaflet qty 1000 nos. no smoking stickers, smoke detector stickers and bio toilet stickers should be made up of high quality pvc material with four colour indications as per consignee requirement. safety leaflet should be with four fold, lamination and creasing. sample to be approved by consignee before bulk supply. senior section maharashtra 1.00 set => limited...

Balmer Lawrie And Co Limited - Maharashtra

30680758 online auction platform and support services provided by c1 india pvt. ltd godrej ctl decoiling shear effluent treatment plant rinsing chamber with degreasing degreasing unit degreasing/rinsing system chimb painting equipment low voltage switch board 11kva high voltage switch board relays battery charging equipment smoke detector samsung refrigerator deep freezer for canteen aquaguard officer canteen aquaguard officer canteen water cooler recold gyser ups aplab 20kva fountain unit wolf make angle grinder overhead water tank under ground 15 kl ldo storage tank water storage executive tables & desks combo staff table with side board locks & cupboard steel shelving rack filing cabinet cabinet, side unit slotted angle rack chair chair chair with arms chair wooden partition revolving chair revolving chair wooden cupboards filing cabinet (from bdc) book case (trfd from bdc 1999/00) filing cabinets 5.11.90 file cabinets 5.5.98 filing cabinets cabinets, side units, tables, partitio slotted angle racks (04 03 93) lot c items description fittings & installation aircirculators fittings vapour lamps phase khaitan exhaust fan crompton ceiling fans lot d items description canteen utensils lot – e items description misleneous non useful and obsolate scrap items compound baking oven with m.s. chimneys and conveyor...

Department Of Fertilizers - Maharashtra

30603401 bids are invited for 300083116 multi function energy meter as per specifications for 3ph 3wire balanced load panel mounting flush type design suitable for ht energy and power measurement , 300102082 eight zone conventional fire alarm control panel having addressable featurs with battery back up suitable for upto 30 smoke detectors per zone , 300079522 plug in photoelectronic smoke detector sensor forconventional alarm system having programmability sensitivity & addressable features,model: 2351 with base model: b401,make: system sensor. total quantity : 1...

Indian Army - Maharashtra

30490506 bids are invited for job work required for repair replacement of unsv defective apfc lt panel and connected items at sub station no. 2 at site p af stn thane under ge (af) thane (i) m&l for testing of apfc panel for proper functioning in manual & auto mode, re wiring burnt out wires, replacing the wiring ducts/ casing capping and cleaning and replacing the unsv spares parts and testing complete all as directed by engineer in charge. each 01.(ii) fixing only in repairs 4 p power contactor type mcx, ac 1, rating 63amps, ml 4 including necessary connection complete all as specified and directed 01 no. make l&t/ schneider/sciemns/c&s(iii) fixing only naturally air cooled double dielectric heavy duty 440 v 50 hz watt less power capacitors watt less power capacitors wattage not more than 0.5 watt per kvar conforming to is 13340 and 13341 isi marked and conforming to iec 831 1 of rating capacity 10 kvar 02 nos.make l&t/epcos/schneider.(iv) fixing only naturally air cooled double dielectric heavy duty 440 v 50 hz watt less power capacitors wattage not more than 0.5 watt per kvar conforming to is 13340 and 13341 isi marked and conforming to iec 831 1 of rating capacity 15 kvar 02 nos. make l&t/epcos/schneider.(v) fixing only naturally air cooled double dielectric heavy duty 440 v 50 hz watt less power capacitors wattage not more than 0.5 watt per kvar conforming to is 13340 and 13341 isi marked and conforming to iec 831 1 of rating capacity 25 kvar 01 no. make l&t/epcos/schneider. , job work required for repair replacement of unsv defective smoke detector and control panel at mts & logistic sec at site p af stn thane under ge (af) thane (i) m&l for dismantling existing unserviceable defective parts of smoke detector and fire alarm system and re fixing of serviceable parts all as specified and directed. job 01.(ii) s&f for digital addressable fire alarm control panel 4 zone with lcd display, signaling line circuit loop ranging between one and thirty depending on protoco...