Central Railway - Maharashtra
40358241 auction sale of scrap and unserviceable condemned magnetic & non magnetic siainless steel duct frame with cotton attachment in dismenteled and broken condition of sort & sizes...
40358241 auction sale of scrap and unserviceable condemned magnetic & non magnetic siainless steel duct frame with cotton attachment in dismenteled and broken condition of sort & sizes...
36403422 auction sale of scrap and unserviceable condemned magnetic & non magnetic siainless steel duct frame with cotton fibre,plastic,rubber etc attachment in dismenteled and broken condition of sort & sizes...
36099739 auction sale of scrap and unserviceable condemned magnetic & non magnetic siainless steel duct frame with cotton attachment in dismenteled and broken condition of sort & sizes...
17759449 supply of laboratory fume hood : specifications for fume hood. 1.size: 1.5m ( l ) x 0.9m ( d ) x 2.4m ( h ) 2.inner dimensions: 1.5m ( l ) x 0.9m ( d ) x 1.6 m ( h ) 3.material of construction: any of the following material – ( 1 ) galvanised iron ( gi ) min 1 mm as per is 277 standard. or ( 2 ) crca min 1 mm and as per is 277 standard. epoxy painting or automated powder coating. 4.construction of interior: corrosion, chemical & heat resistant, fire retardant, smooth finish, easily cleanable panels. automated powder coating. 5.baffle arrangement: a stable, non adjustable 2 or 3 point suction systems. 6.design structure: floor mounted. 7.work top: granite work top of at least 17 mm thick, chemical resistant, splash and spillage proof. 8.sash ( shutter ) : transparent safety glass, smooth operation. horizontal and vertical sliding, toughened glass of ~ 6 mm thick with counter balance system. 9.lighting: fluorescent or led lights, 2 nos. 10.electrical utilities: 6 nos. electrical sockets 5 6 / 15 16 a rating. reputed make single phase 50hz. 11.chemical storage base cabinet: corrosion resistant, chemical and heat resistant internal walls, fire retardant, smooth finish, easily cleanable panels. automated powder coating. 12. level adjusting screws: to adjust the fume hood level by +or 10 mm. 13.exhaust port: two point exhaust system. fumes to be exhausted without turbulence at the exhaust port. ensure low noise level. 14.design: en14175 or ashrae 110: 2016 ( latest edition ) certified. 15.sink: sink ( 5 10 cm w x 10 20 cm l ) , water tap arrangement, and chemical / acid resistant material. centrifugal blower: 1no. it should satisfy safe velocity norms. 1.air suction capacity: as per safe fume hood airflow pattern. 2.motor: reputed make, with isi mark, 1 2 hp. 3.duct diameter: 8 10 inches. stainless steel duct collar. duct joints shall be of flanged connections with rubber gasket in between. 4.drive: direct drive. installation: 1.fumehood: location – ground floor lab. all plumbing inside the fumeh...
17759404 supply of laboratory fume hood : specifications for fume hood. 1.size: 1.5m ( l ) x 0.9m ( d ) x 2.4m ( h ) 2.inner dimensions: 1.5m ( l ) x 0.9m ( d ) x 1.6 m ( h ) 3.material of construction: any of the following material – ( 1 ) galvanised iron ( gi ) min 1 mm as per is 277 standard. or ( 2 ) crca min 1 mm and as per is 277 standard. epoxy painting or automated powder coating. 4.construction of interior: corrosion, chemical & heat resistant, fire retardant, smooth finish, easily cleanable panels. automated powder coating. 5.baffle arrangement: a stable, non adjustable 2 or 3 point suction systems. 6.design structure: floor mounted. 7.work top: granite work top of at least 17 mm thick, chemical resistant, splash and spillage proof. 8.sash ( shutter ) : transparent safety glass, smooth operation. horizontal and vertical sliding, toughened glass of ~ 6 mm thick with counter balance system. 9.lighting: fluorescent or led lights, 2 nos. 10.electrical utilities: 6 nos. electrical sockets 5 6 / 15 16 a rating. reputed make single phase 50hz. 11.chemical storage base cabinet: corrosion resistant, chemical and heat resistant internal walls, fire retardant, smooth finish, easily cleanable panels. automated powder coating. 12. level adjusting screws: to adjust the fume hood level by +or 10 mm. 13.exhaust port: two point exhaust system. fumes to be exhausted without turbulence at the exhaust port. ensure low noise level. 14.design: en14175 or ashrae 110: 2016 ( latest edition ) certified. 15.sink: sink ( 5 10 cm w x 10 20 cm l ) , water tap arrangement, and chemical / acid resistant material. centrifugal blower: 1no. it should satisfy safe velocity norms. 1.air suction capacity: as per safe fume hood airflow pattern. 2.motor: reputed make, with isi mark, 1 2 hp. 3.duct diameter: 8 10 inches. stainless steel duct collar. duct joints shall be of flanged connections with rubber gasket in between. 4.drive: direct drive. installation: 1.fumehood: location – ground floor lab. all plumbing inside the fumeh...