Military Engineer Services - Maharashtra

40818886 tender for repair / maintenance of focus / flood lights highmast light and allied works at nda khadakwasla.; 1 taking down the existing light fittings on multi mounting brackets from 16 / 21 mtrs highmast pole by taking on ground repairs / replacing the defective parts like electronic drivers connection wires and refixing the same to its original position complete all as specified and directed.note: ( i ) cost of spares , electronic drivers, connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of sch a here in below. ( ii ) the defects / repair of the floodlight making them functional after handing over defective floodlights of highmast ( iii ) maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and gettingit authenticated. ( iv ) safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. ( v ) vehicle mounted hydraulic ladder shall be provided on contractors request which will be measured separately under schedule c. 2 supply only following flood light spares of branded make as mentioned in the list of make enclosed with particular specifications for replacement : mcb tpn 230 volts c curve 63 amps 3 ditto all as per item no 2 above but mcb tpn 230 volts c curve 40 amps make : l&t / indoasian / legrand 4 ditto all as per item no 2 above but digital time switch, din type daily / weekly with 2 change over ( co ) , 16 amps 230 volts make : l&tor legrand / indoasian 5 ditto all as per item no 2 above but power contactor 16 / 18 amps 3 pole a.c. with 230 volts coil 6 ditto all as per item no 2 above but power contactor 40 amps 3 pole a.c. with 230 volts coil. 7 ditto all as per item no 2 above but pvc insulated copper conductor frls grade two core cable 2.5 sqmm, isi marked 8 ditto all as per item no 2 above but pvc insulated aluminium conductor frls grade two core cable 2.5 sqmm, isi marked 9 ditto all as per item no 2 above but mccb 63 amps 4 pole 415 v 10 ditto all as per item no 2 above but mcb dp 230 volts b curve 6 32 amps 11 ditto all as per item no 2 above but electronic driverfor 200 watts flood lights make should be as per the existing manufacturer 12 ditto all as per item no 2 above but electronic driverfor 150 watts flood lights make should be as per the existing manufacturer 13 ditto all as per item no 2 above but electronic driverfor 100 watts flood lights make should be as per the existing manufacturer 14 ditto all as per item no 2 above but electronic driverfor 50 watts flood lights make should be as per the existing manufacturer 15 ditto all as per item no 2 above but surge protection device ( spd ) of capacity 10 / 20 kv compatible with industrail & outdooor led fixtures make should be as per the existing manufacturer 16 dismantling / taking down thepole upto 16 / 21 metre height of high mast light by engaging suitable crane and repairing by replacing the unserviceable top pully of pole and other part such as winch motor, steel wire, power cable and servicing , toping of oil and greasing the gear wheel assemblyand hoisting, refixing and connecting up complete all as specified and directed.note : ( a ) the repair oflight fittings and light fitting spares are measured and paid separately. ( b ) spares such as steel wire, power cable etc will be measured and paid separately. ( c ) the entire work shall be carried out with well experienced professionals who undertake the high mast poles dismantling / repair works. ( d ) the quoted rate shall includes provn of minor spares such as screws, bolt / nuts, grease etc 17 supply onlystainless steel rope twisted of size10mm / 6 mm dia with necessary connections proper binding on both sides from bottom drum mast top connecting hook complete all as specified and directed. 18 supply only gear box oil of grade ep 90 / 140 in standard packed / sealed container including drain out old gear box and filling up new gear box oil complete all as specified and directed.make : hp / servo / valvoline 19 disconnecting electric connectionand taking down carefullyfractional motor from highmast housing of any type and capacity as described below: removing the burnt winding ofmotor rewinding with super enameled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position complete all as specified and directed. 20 supply only3 phase induction motor of 1hp heavy duty 415 v ac50 hz 1500 rpm suitable for lifting of highmast winch complete all as specified and directed. 21 supply & laying, jointing & testing of ug lt cables xlpe insulated, aluminium conductor multi stranded armoured heavy duty 1100 volt grade cross sectional area 16 sqmm 4 core laid in trenches / ducts / along poles / through pipe under road etc with new aluminium lugs of cable size including taking out of existing unserviceable cable complete all as specified and directed. 22 ditto all as per item no 21 above but size 10 sqmm 4 core 23 ditto all as per item no 21 above but size 4 sqmm 3 core 24 excavation in trenches in hard / dense soil n.exc 1.5 m wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing / trimming sides and levelling / grading and ramming of bottom of excavation complete all as specified and directed. 25 returning, filiing in incl spreading, leveling watering and well ramming excavated soil inlayers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified and directed. 26 removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point complete all as specified and directed. 27 supply and laying 40 mm outer dia, double walled corrugated ( dwc ) hdpe duct pipe confirming to is 16205 pt 24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e coupler, tee, elbow clamp for cable protection including taking down old unserviceable pipe complete all as specified and directed. 28 supply and fix in replacement of sintex box thermo plast ( weather proof ) ip 66, on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size withconnector for connecting incomming and outgoing of cableincluding 01 no of mcb sp 6 amps to control the pole light circuit andms brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified and directed.make: sintex cat pat no gsjb 1414 or equivalent in makes as mentioned at makes list in ps 29 s&f distribution box 2 module 230v, 5 hz, ip 65 & ik 09 class ii, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty 1 nos, coppper fork type 100 a busbars as short link including end caps complete all as specified and directed. 30 s&f in replacement mcb db 02 way spn ( single door ) sheet metal enclosure factory made suitable for mcb dbs 240 voltswith 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including mcb spn 06 amp 230v, 50 hz complete all as specified and directed. 31 m&l for cutting hard standing by providing suitable t&p to make suitable size bore for supply & fixing 32 mm dia pipe in road / cutting hard etc. including the cost of making good the disturbed surface and matching with existing ( chequered tiles / road / pcc ) complete all as specified and directed.note : quoated rate shall includes supply of 32 mm dia gi pipe 32 s & f in replacementof 100 watts flood light white in colour, lm6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and ip 66 protection complete , single phase, suitable for highlighting architectural facade and general purpose lighting etc fixing in ms chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structureas reqd at the site complete all as specified and directed. make: havells cat part no. jetaalbafloodlight100w or equivalent in makes as mentioned at makes list in ps 33 s & f in replacement of 150 watts flood light white in colour, lm6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and ip 66 protection complete , single phase suitable for highlighting architectural facade and general purpose lighting, etc fixing in ms chanel by drilling hole of suitable size, using nut, bolts and washers of suitable size including suitable mounting structure as reqd at the sitecomplete all as specified and directed. make:havells cat part no jetaairisfl150wled757arnbltg or equivalent in makes as mentioned at makes list in ps 34 s & fin replacement of 200 watt led flood light luminaire with separate driver assemble boxwith secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and ip 66, with suitable mounting structure as per site requirement complete all as specified and directed. make : havells cat part no jetavalourfl200wled757modnbltg or equivalent in makes as mentioned at makes list in ps 35 suply & fixing in replacement of 300 watt led flood light luminaire with separate driver assemble boxwith secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and ip 66, with suitable mounting structure as per site requirement ccomplete all as specified and directed.make : havellscat part no jetavalourfl300wled757modnbltg or equivalent in makes as mentioned at makes list in ps 36 supply & fix in replacement of 400 watt led flood light luminaire with separate driver assemble boxwith secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and ip 66, with suitable mounting structure as per site requirement complete all as specified and directed.make: havells cat part no jetavalourfl400wled757modnbltg or equivalent in makes as mentioned at makes list in ps 37 supply and fix in replacement of integral led aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on highmast light frame complete all as specified and directed.make: bajaj cat part no: bgav302led or equivalent in makes as mentioned at makes list in ps 38 supply and fix in replacement of 1x18 watt ww ( 3000k ) led bollard outdoor gate lightwith polycarbonate diffuser and ip 65 protection incl demolition of existing pcc and make suitable pcc for new bollard as per site requirement and fixing arrangements complete all as specified and directed.make : luker cat part no: lglrbge 27 or equivalent in makes as mentioned at makes list in ps 39 supply and fix in replacement of 1x10 watt ww ( 3000k ) led outdoor gate lightwith polycarbonate diffuser and ip 65 protection incl demolition of existing pcc and make suitable pcc for new bollard as per site requirement and fixing arrangements acomplete all as specified and directed.make luker cat part no: lglsmd or equivalent in makes as mentioned at makes list in ps 40 s&f in replacement of led rope light out door 12 w 24v ip 68 with warm white incl 2 pin power supply connector, connector pin, and end cap as per site requirement fixing at roof of the bldg with suitable pvc saddles for every one mtr on rope. make : luker cat part no lso68 or equivalent in makes as mentioned at makes list in ps 41 s & f in repairs connector suitable for ledstrip outdoor 12 w 24 v ip 68 fittings complete all as specified and directed. 42 s&f in repairs connector pin suitable for ledstrip outdoor 12 w 24 v ip 68 fittings complete all as specified and directed. 43 supply and fix in replacement 10 wattsturdy ip 65 led bollard with excellent light out put through its pmma window ensuring maximum illumination aspect in surrounding. incl demolition of existing pcc and make suitable pcc ( 1:2:4 ) type b1 for new bollard as per site requirement and fixing arrangements complete all as specified and directed.make havells cat part no mountbl10wled830psymtopmma or equivalent in makes as mentioned at makes list in ps note: quoated rate shallincludes provn of pcc work to bollard 44 suply & fixing in replacement of 60 wled stellar led post top offering combination of sturdy design, execllent illumination and aesthetics in one go. ip 66 and ik 10 rating ensures it stands tall amid varid environemtnal conditions , incl suitable arrangements for pole 3.5 mtr decorative pole complete all as specified and directed.make havells cat part no nebulapt60wled857psymtopc or equivalent in makes as mentioned at makes list in ps 45 suply & fixing in replacement of 40 wled new generation, ip 65 led post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power leds as light source. clear cover offers bright illumination for different applications , incl suitable arrangements for pole 3.5 mtr decorative polecomplete all as specified and directed.make havells cat part no rubypt40wled757psymtopc or equivalent in luker / cromopton / philips / halonix / benlo / bajaj or any other approved makes 46 supply and fix in replacement integral 25 watt ledpost top lantern black / copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessorieson on existing gi pipe of diameter complete all as specified and directed. make : havells cat part no coralpt25wled757psymtopc or equivalent in makes as mentioned at makes list in ps 47 m&l for straight through joint ( epoxy ) for16 sqmm to 35 sqmm 3.5 core pvc insulated and sheathed aluminium conductor under ground cableincl freud , thimbles, nut & bolts, washers etc and testing afterjointing complete all as specified and directed.make: m seal / raychem / cabseal / denson 48 s&f pvc insulated multistranded copper conductor 3 core 10 sqmm for connection of floodlighton rooftopand fixing with suitable size clamp and connecting with suitable size copper lugs including taking down of exisitng old u / s conductor complete all as specified and directed. 49 s&f pvc insulated multistranded copper conductor 4 core 10 sqmm for connection from panel to high mast fitting, and connecting with suitable copper lugs including taking down of exisitng old u / s conductor complete all as specified and directed. 50 s & f in replacement busbar panel weather proof outdoor type single door, fabricated out of3.15 mm thick crcasheet with epoxy powder coating of ral 7035 ( siemens gray ) shade with matt finishwith seven tank pre treatment process.the panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection ip 55, gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.all doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. the panel shall be provided with aluminium bus bars, 300mmx40mmx 5mm ( thickness ) electrolytic grade of adequate rating.the bus bars and interconnecting links shall be insulated with heat shrinkable pvc sleeve with 4. ryb & black colour coding and fix horizontally. the bus bars shall be supported on unbreakable, non hygroscopic smc insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles all joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. the panel shall be provided with 04 nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted on wall and suitable fixing arranement as per site requirement. the overall size of the busbar panel shallbe 350mmx200mmx 400mm ( lxbxh ) .including pcc 1:3:6 complete all as specified and directed. 51 supply, install, commission and testing cubical type lt panel board, outdoor type, manufactured by a cpri approved factory, floor mounted, dust & vermin proof, front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm ms angle iron frame work and crca sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. the panel shall be suitable for 415 volts, 50 hz, 3 phase 4 wire system and shall be complete with suitable capacity aluminium bus bar ( 1.5 times the incoming switch gear current rating ) with suitable size of pvc insulated copper conductor, thimbles glands including dismantling of exting u / s panel board complete all as specified and directed with the following accessories : ( a ) mccb 63 a 4 pole 415 v 25 ka 01 no ( incoming ) ( b ) mcb 40a sp pole 10 ka l&t 04 nos ( c ) street light timer digital switch 1 no ( d ) power contracts 32 mnx 3 pole 1 no ( e ) aluminium bus bar 4 strip ( f ) internal wiring for panel incl insulators, sleeves etc ( g ) painting and treatment as per cpri 52 m&l for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm of 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 in ssr part i connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, pcc earth pit with cover, excavation & earth work, testing on completion etc complete all as specified and directed 53 supply & fix replacement of gi tubing light grade 40 mm dia isi marked appx 1 mtr to 1.5 mtr long with flat iron base for mounting of flood lightwith all fittings inclnut, bolt, washers suitable size and also make the hole for pole for entry of the2.5 sqmm pvc conductor complete all as specified and directed 54 s&f in replacement of cylindrical panel locks of suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments and complete all as specified and directed 55 s&f in repalcement of old broken cold rolled mild steel hinges of existing busbar etc of suitable size or as per sample including welding and painting to match with existing colour of panel sheet etc complete all as specified and directed 56 disconnecting exisitng incoming and outgoing cables from existing busbar after taking proper shutdown and excercising all safety precautions, human safety, removing the old busbarpanel complete with its accessories and setting a side at safe place and m&l in replacement of crca sheet of thickness 2mm thick with epoxy powder coating of ral 7032 ( smoke grey ) busbars angle iron supports etc including all cables re terminated according to existing system with busbar panel all as specified and directednote: ( a ) the quoted rate shall includes preparation of existing surface of busbar and supporting surface angle iron of busbar by scraping down, peeled off old paint, cleaning etc and applying one coat of smoke grey paint to busbar incluidng clenaing of busbars from inside by blowing compressed air etc complete ( b ) size and design of item shall be executed as per site requirement and also approved by engr in charge...

Rural Development Department - Maharashtra

40803319 providing and supplying electrical mterial at grampanchayat wadhu bk providing and supplying electrical mterial at grampanchayat wadhu bk tal shirur pune , material list , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) , supplying anderecting streetlightbracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cementconcrete foundationincluding excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered andwithnecessarycuringandfinishinginanapproved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) , supplyinganderectingsteeltubularswagedpole139.7x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplyinganderectingsteeltubularswagedpole165.1x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, baseplateinprovidedfoundation ( weight147kg ) as per specification no. oh pl / stp , supplyinganderectingsteeltubularswagedpole165.1x 139.7x114.3mmdia.with4.5x4.5x3.65mmthickness ( 5.60+2.7+2.7m ) lengthtotal11mlongwithpolecap, baseplateinprovidedfoundation ( weight175kg. ) asper specification no. . oh pl / stp , supplying and erecting street light bracket made from 25mm.dia‘b’classg.i.pipe, 0.6m.inlengthalongwith polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying, tpmcb 40a to 63a in provided distribution board , providingpairofdulytestedrubberhandglovesasper is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse , supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplyingpvcinsulatedpvcroundsheathed1.5sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) , supplyinganderectingledstreetlightfittingsuitablefor 60wlamp, includinglamp, with pf > 0.95 class ip 65 and abovehousingofpressurediecastalluminiumalloyand heat sink 2 9 5 , supplyinganderectingledstreetlightfittingsuitablefor 26wto36wledstreetlight, includinglamp, withpf> 0.95classip65andabovehousingofpressurediecast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplyinganderectingledfloodlightfittingof120w, includinglamp, withpf>0.95, classip65andabove housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm 7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 , supplying, erecting&markingtpmcb6ato32ampin provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying&erectingcrimpingtypecoperlugsforcable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 , supplying&erectingmainswith2x1.5sq.mmf.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 , supplyinganderectingmainswithisimarkwp2x6sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplyinganderectingmainswithisi markwp2 x2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l / t contactor , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , cable joint kit upto 16 sq. mm cable , street light pole box frp , cement street light pole clamp , m.s. street light pole clamp , servicing and primary maintenance of street light pole 1 vis , supplying and laying ( including excavation of suitable width & , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker ( 1 hours , tree triming for overhead line , supplyinganderectingsolarpanelcomprising , supplying and erecting approved makebattery with capacity , servicingandprimarymaintenanceofsolarlightpole1 , solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. , providing rental basis hydraulic bucket vehicle of highth 13 , 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor with , 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm , 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm , 7 1 35 supplying, erecting & terminating xlpe armoured , 5 3 4 supplying, erecting & marking spmcb 40a to 63a c series ( for motor / power ) in provided distribution board as per specification no. sw swr / mcb , 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb , 5 3 8 supplying, erecting & marking dpmcb 40a to 63a, c series ( for motor / power ) in provided distribution board as per specification no. sw swr / mcb , 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb , 5 3 15 supplying, erecting & marking tpmcb 40a to 63a in provided distribution board as per specification no. sw swr / mcb , 5 3 17 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board as per specification no. sw swr / mcb , 5 3 27 supplying, fixing and commissioning mcb type change over switch 2 pole, 25 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos , 5 3 28 supplying, fixing and commissioning mcb type change over switch 2 pole, 40 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos , 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos , 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos , 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu , 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu , 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu , 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. , supplying and erecting icdp switch 10a to 63a , cable joint kit for armoured cable 20 upto 120sq. mm cable , gi tar , ahuja speaker system ( pa ) 110w to 250w with mic , kit kat type fuse 16a 32a 63a 120a , taparia tester , spaner set , control panel hrc fuse , supplying and erecting transformer fidder piller , 5 2 19 supplying & erecting street light control panel in , 2 5 5 supplying and erecting led street light fitting suitable , service charges for maintainance of aboe material per day...

Military Engineer Services - Maharashtra

40800644 tender for provision of 06 nos security watch towers at hemrl, pune; 1 lumpsum price worked out by the contractor for construction of watch tower with rcc framed structure ( g+2 ) complete all as shown on drawings and as specified. 2 lump sum price worked out by the contractor for “site development, earthwork and excavation as listed in schedule ‘a’ part iirepresenting_______ % ______________ percent above / below the lump sum price of `10, 64, 924.40 inserted by the mes in schedule ‘a’ part ii 3 lump sum price worked out by the contractor for “internal electrification” as listed in schedule ‘a’ part iii representing__________ % ____________ percent above / below the lump sum price of `3, 92, 596.26 inserted by the mes in schedule ‘a’ part iii 4 lump sum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’ part iv representing__________ % ____________ percent above / below the lump sum price of ?37, 495.56 inserted by the mes in schedule ‘a’ part iv 5 lump sum price worked out by the contractor for roads / paths / culverts” as listed in schedule ‘a’ part v representing______ % _________________ percent above / below the lump sum price of `4, 62, 888.00 inserted by the mes in schedule ‘a’ part v 6 lump sum price worked out by the contractor for external electric supply” as listed in schedule ‘a’ part vi representing_______ % __________________ percent above / below the lump sum price of `13, 70, 389.10 inserted by the mes in schedule ‘a’ part vi 7 lump sum price worked out by the contractor for external water supply” as listed in schedule ‘a’ part vii representing_______ % __________________ percent above / below the lump sum price of `3, 22, 790.38 inserted by the mes in schedule ‘a’ part vii 8 lump sum price worked out by the contractor for “sewage disposal” as listed in schedule ‘a’ part viii representing_______ % _________________ percent above / below the lump sum price of `2, 72, 385.09 inserted by the mes in schedule ‘a’ part viii 9 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’ part ix representing_______ % _________________ percent above / below the lump sum price of `14, 55, 665.68 inserted by the mes in schedule ‘a’ part ix 10 lump sum price worked out by the contractor for “special item of work” as listed in schedule ‘a’ part x representing_________ % __________________ percent above / below the lump sum price of `20, 161.00 inserted by the mes in schedule ‘a’ part x 11 this schedule is not prepriced by mes and the prepriced rate indicated in col 5 as ?0.00 indicates this fact only. the tenderer is required to quote their rates in column 6. this schedule constitutes sl. item nos. 12.00 to 27.00. 12 internal electrifications&f, enviroment friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge lit led luminaire comorising of high brightness led 10 watt with polycarbonate housing integrated electronic driver complete with all accessories including internally prewired all as specified and directed.make: havells cat no. hexaft10wled857ssymbopc / philips / crompton greaves / fortune arrt. 13 s&f, led tube light fitting 1 x 20 w, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs20wled865spcss / philips / crompton greaves / fortune arrt. 14 s&f, led tube light fitting 1 x 10 w, 2 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs10wled865spcss / philips / crompton greaves / fortune arrt. 15 s&f, led building security luminaries 25 watts pressure die cast aluminum housing with ip 66 and replaceable integrated electronic driver led as light sources housing complete with all accessories internally prewired and suitable for pole 40 mm dia all as specified and directed.make: cat part no. endurasundownsl25wled765pasybopcihd of havells / philips / crompton greaves / fortune arrt. 16 s&f, suitable shape street light fitting bracket made out of gi pipe 40 mm dia med grade or of suitable size as per requirement and shape, clamps made out from ms flat of size 40 mm x 6 mm with nuts and bolts ( length of pipe should not less than 1.5 m ) and applying single coat of aluminium paint over a coat of red primer painting complete all as specified and directed by engineer in charge. 17 s&f, ventilating fan metal type 300 mm sweep ac 230 volts 900 rpm with all accessories and louvers including provisioning of hole in wall, making good the disturbed surfaces of wall complete. make: havells venti air ds / crompton greaves / usha. 18 s&f, spn distribution board double door flush type all as per is 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories all as specified and directed by engineer in charge.note: mcbs for out goings shall be measured and paid for separately under relevant items. 19 s&f, connecting and testing mcb single pole and neutral ( mcb spn ) 230 volts of capacity 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 20 s&f, connecting and testing mcb single pole ( mcb sp ) 220 volts of capacity 6 to 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 21 supply, fixing & commissioning of cpri approved factory made lt cubical panel board out door type conforming to is / iec 61439 1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415 volts, 3phase, 50hz having aluminium bus bar of capacity 200 amps tpn duly colour coded and for neutral supported with dmc / smc insulators colour coded with heat shrinkable sleeve having short circuit current with minimum 65ka for one second and suitable for internal connection including instaneous over load and earth fault relays complete with digital type volt meter and ammeterincluding suitable range of cts of metering, selector switches for volt meter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels, nut bolts, washers etc, including control accessories: 22 ( a ) incoming mccb 4 pole 415v, 100 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 25 ka 01 no. ( b ) outgoing mccb 4 pole 415v, 63 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 16 ka 02 nos. ( c ) outgoing mcb spn, 32 amps 10 ka c series 230v ac supply 01 no. ( d ) panel mounted type digital multifunctional energy meter a, v, z, kw, pf ct operated, lt 3 phase, 4 wire, including ct ratio 400 / 5 01 no. ( e ) led indicating lamps sets ryb 01 set ( f ) astro time switch 01 no. 23 s&f, two way bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete of size 15mm dia pipe complete all as specified and directed. 24 s&f, 1.2m long chromium plated health faucet including holder fixed to wall complete all as specified and directed by engineer in charge. 25 m&l for cutting of roads / plinth for removal / lalying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed by engineer in charge.note: width 450 mm and depth 600 mm to be excavated for road cutting. 26 construction of septic tank of 5 users capacity, excavation in hard soil, foundation in pcc, brick work in cm 1:4, rcc manholes cover, vent shaft and sludge chambers complete all as specified and directed and shown on td drawings. 27 construction of soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of fly ash brick masonary in cm, rcc cover slab in m25 / sfrc cover, interconnecting pipes of rcc / dwc complete filled with brick bats complete all as specified and directed and shown on td drawings. 28 supply, fix, connecting, testing & commissioning of high intensity long range, auto swivel, led search light, beam range 500 meters ( min ) , 1x200w, single, led light, efficiency >130lm / w, pf>0.95, cct 5500k 6500k, optional grade pmma pc lens, anti uv oxidation, narrow beam 8 degree, die cast lm6 body with air fins, fully powder coated, working voltage 150to270, 50hz constant current, reflector / lens efficiency >90% average lux level at 5 meter 9000 ( min ) with circle of approximately 600mm, ip 65, confirming to lm79 / lm80 search light should be installed on disc of revolving mechanism with suitable motor gear unit and design such to rotate 360 degree continuously over the night in horizontal plane with speed controller ( 1 to 10 rpm ) & r / f buttons and inbuilt push to tilting option upto 45 degree. a separate wall mounted wired control panel ( consist of mcbs, v meter, fuse, led indicators ) with smooth and safe operation remotely including revolving mechanism fully covered with weather & rust proof fiber box with maintenance window / door with provision of 4 nos foundation holes at bottom for proper installation complete all as specified and directed.make: cat no. mrsl lrfll25 pc20 of make kalin / point blank range ( pvt ) ltd model no. yk revo 200dr / jainsons electronics model no. jmrsl 200 / bajaj / philips / wipro / crompton / havells / fortune arrt....

Department of Higher Education - Maharashtra

40504207 bids are invited for switch , socket , socket 1 , panel light , time switch , ballast , socket 2 , switch 2 , led tube , bell push , bell push1 , tap , copper pipe , cell , tube total quantity : 4560...

Directorate Of Municipal Administration - Maharashtra

40455221 supplying electrical material for shirdi municipal council shirdi for year 2023 2024 1 street light poles 2 supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp 3 supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 5+1.75+1.75 m ) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. ( weight 109 kg. ) as per specification no. oh pl / stp 4 supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 113 kg ) as per specification no. oh pl / stp 5 supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 147 kg ) as per specification no. oh pl / stp 6 supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness ( 5+2.5+2.5 m ) length respectively and total 10 m long with pole cap, base plate in provided foundation ( weight 160 kg ) as per specification no. oh pl / stp 7 supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x4.5 x3.65 mm thickness ( 5.60+2.7+2.7 m ) length total 11 m long with pole cap, base plate in provided foundation ( weight 175 kg. ) as per specification no. oh pl / stp 8 supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 5.4 x 4.5 x 3.65 mm thickness ( 5.8+3.1+3.1 m ) length total 12 m long with pole cap, base plate in provided foundation ( weight 208 kg. ) as per specification no. oh pl / stp 9 supplying steel tubular swaged type welded pole with upper portion hydraulically bent swan neck, 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.50 x 3.65 mm thickness ( 5+2+3 m ) respectively ( net vertical height 9 m. ) total length 10 m long with base plate in provided foundation. ( weight 156.75 kg ) as per specification no. oh pl / stp 10 supplying steel tubular swan neck swaged type welded pole with upper portion hydraulically bent , 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5.6+2.7+2.7 m ) respectively total ( net vertical height 10 m. ) 11 m long with base plate in provided foundation. ( weight 175 kg ) as per specification no. oh pl / stp 11 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 12 supplying and erecting rolled steel joist ( girder ) pole 150 x 80 mm / 150 x75 mm ( 14.9 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 13 supplying and erecting rolled steel joist ( girder ) pole 175 x 85 mm ( 19.6 kg / m ) with provided base plate in provided foundation as per specification no. oh 14 supplying and erecting rolled steel joist ( girder ) pole 100 x 116 mm ( 23 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 15 supplying and erecting rolled steel joist ( girder ) pole 200 x 100 mm ( 25.9 kg / m ) with provided base plate in provided foundation as per specification no.oh pl / rsj 16 supplying and erecting rolled steel joist ( girder ) pole 152 x 152 mm ( 37.1 kg / m ) with base plate in provided foundation as per specification no. ohpl / rsj 17 supplyingg.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl / gip 18 supplyingm.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl / gip 19 streetlightfittingsnote 1 ) driver and luminaire shall be of same make.2 ) lm79 and all other reports of all luminaires shall be from accredited nabl laboratory.3 ) manufacturer logo shall be embossed on all pressure die cast luminaires and logo shall not be screen print / sticker type.4 ) all luminaires shall conform to respective is.5 ) there shall be provision for earth wire termination. 20 supplying integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf / fls2. 21 supplying integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf / fls2. 22 supplying integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf / fls2. 23 supplying integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf / fls2. 24 supplying integrated led street light fitting 60w 65 ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including drivercomplete with 3 years warranty as per specification no fg odf / fls2. 25 supplying integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf / fls2. 26 supplying integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf / fls2. 27 supplying integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3 years warranty as per specification no fg df / fls2. 28 supplying integratedled street light fitting 120w ip65 & ik08 class having ingle piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf / fls2. 29 supplyingintegrated led street light fitting 130 140w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 15600 lumens, min. efficacy of 120 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf / fls2. 30 supplyingintegrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including dri 31 streetlighthighway fittings note1 ) driver and luminaire shall be of same make.2 ) manufacturer logo shall be embossed on all pressure die cast luminaires and logo shall not be screen print / sticker type.4 ) all luminaires shall conform to respective is.5 ) there shall be provision for earth wire termination. 32 supplying integrated led highbay fitting 70wip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min.10000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2 33 supplyingintegrated led highbay fitting 100w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 15000 lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4 kv, life class of50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 34 supplyingintegrated led highbay fitting 135wip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000lumens, min. efficacy of 145 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50, 000 hrs. at l50b50 , including driver complete with 3 year warranty as perspecification no fg odf / fls2. 35 supplying street light drivres supplyingelectronic type driver for outdoor led fittingsw suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. note material make shall be phillips / cromption / haveles and is branded company 36 upto 25w 37 26w 45w 38 46w 75w 39 76w 100w 40 101w 150w 41 151w 200 w 42 led lamp supplying 230 v integral type led lamp for street light note material make shall be phillips / cromption / haveles and is branded company 1 ) system efficacy shall not be less than 100 lumens / watt2 ) led lamp / tube shall carry minimum two year warranty. 43 18 w 22 w 44 23 w 25 w 45 26 w 40 w 46 41 w 50 w 47 51 w 60 w 48 61 w 70 w 49 71 w 75 w 50 76 w 90 w 51 100 w 110 w 52 street light pole bracket 53 25 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia 54 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia 55 25 mm. dia ‘ g.i. pipe 1.2 m. in total length. 56 40 mm. dia ‘ g.i. pipe 1.2 m. in total length. 57 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia 58 double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia 59 single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe along with pole cap of 125mm dia 600 mm long 60 double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “b” class g.i .pipe along with pole cap of 125mm dia 600 mm long 61 armoured cables aluminium / copper 62 lt armoured strips cables ( aluminium ) supplyinginsulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, aluminium conductor complete 63 xlpe armouredstrip 64 2 core 4 sq. mm. 65 2 core 6 sq. mm. 66 2 core 10 sq. mm. 67 2 core 16 sq. mm. 68 2 core 25 sq. mm. 69 3 core ( alluminium ) 70 3 core 2.5 sq. mm. 71 3 core 4 sq. mm. 72 3 core 6 sq. mm. 73 3 core 10 sq. mm. 74 3 core 16 sq. mm. 75 3 core 25 sq. mm. 76 3 core 35 sq. mm. 77 3 core 50 sq. mm. 78 4 core ( alluminium ) 79 4 core 4 sq. mm. 80 4 core 6 sq. mm. 81 4 core 10 sq. mm. 82 4 core 16 sq. mm. 83 4 core 25 sq. mm. 84 4 core 35 sq. mm. 85 4 core 50 sq. mm. 86 4 core 70 sq. mm. 87 fr xlpe armouredstrip 88 2 core ( alluminium ) 89 2 core 4 sq. mm. 90 2 core 6 sq. mm. 91 2 core 10 sq. mm. 92 2 core 16 sq. mm. 93 2 core 25 sq. mm. 94 3 core ( alluminium ) 95 3 core 2.5 sq. mm. 96 3 core 4 sq. mm. 97 3 core 6 sq. mm. 98 3 core 10 sq. mm. 99 3 core 16 sq. mm. 100 3 core 25 sq. mm. 101 3 core 35 sq. mm. 102 3 core 50 sq. mm. 103 4 core ( alluminium ) 104 4 core 4 sq. mm. 105 4 core 6 sq. mm. 106 4 core 10 sq. mm. 107 4 core 16 sq. mm. 108 4 core 25 sq. mm. 109 4 core 35 sq. mm. 110 4 core 50 sq. mm. 111 4 core 70 sq. mm. 112 lt armoured round cables ( alluminium ) 113 supplyinginsulated, galvanised steel formed wire armoured ( round ) cable 1100 v, aluminium conductor complete 114 xlpe armouredround cable 115 2 core ( alluminium ) 116 2 core 4 sq. mm. 117 2 core 6 sq. mm. 118 2 core 10 sq. mm. 119 2 core 16 sq. mm. 120 2 core 25 sq. mm. 121 3 core ( alluminium ) 122 3 core 2.5 sq. mm. 123 3 core 4 sq. mm. 124 3 core 6 sq. mm. 125 3 core 10 sq. mm. 126 3 core 16 sq. mm. 127 3 core 25 sq. mm. 128 3 core 35 sq. mm. 129 3 core 50 sq. mm. 130 4 core ( alluminium ) 131 4 core 4 sq. mm. 132 4 core 6 sq. mm. 133 4 core 10 sq. mm. 134 4 core 16 sq. mm. 135 4 core 25 sq. mm. 136 4 core 35 sq. mm. 137 4 core 50 sq. mm. 138 4 core 70 sq. mm. 139 frxlpe armouredround 140 2 core ( alluminium ) 141 2 core 4 sq. mm. 142 2 core 6 sq. mm. 143 2 core 10 sq. mm. 144 2 core 16 sq. mm. 145 2 core 25 sq. mm. 146 3 core ( alluminium ) 147 3 core 2.5 sq. mm. 148 3 core 4 sq. mm. 149 3 core 6 sq. mm. 150 3 core 10 sq. mm. 151 3 core 16 sq. mm. 152 3 core 25 sq. mm. 153 3 core 35 sq. mm. 154 3 core 50 sq. mm. 155 4 core ( alluminium ) 156 4 core 4 sq. mm. 157 4 core 6 sq. mm. 158 4 core 10 sq. mm. 159 4 core 16 sq. mm. 160 4 core 25 sq. mm. 161 4 core 35 sq. mm. 162 4 core 50 sq. mm. 163 4 core 70 sq. mm. 164 armoured strips cables ( copper ) 165 supplyinginsulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. copperconductor complete 166 xlpe armouredstrip 167 2 core ( copper ) 168 2 core 2.5 sq. mm. 169 2 core 4 sq. mm. 170 2 core 6 sq. mm. 171 2 core 10 sq. mm. 172 2 core 16 sq. mm. 173 2 core 25 sq. mm. 174 3 core ( copper ) 175 3 core 2.5 sq. mm. 176 3 core 4 sq. mm. 177 3 core 6 sq. mm. 178 3 core 10 sq. mm. 179 3 core 16 sq. mm. 180 3 core 25 sq. mm. 181 4 core ( copper ) 182 4 core 4 sq. mm. 183 4 core 6 sq. mm. 184 4 core 10 sq. mm. 185 4 core 16 sq. mm. 186 4 core 25 sq. mm. 187 4 core 35 sq. mm. 188 4 core 50 sq. mm. 189 4 core 70 sq. mm. 190 fr xlpe armouredstrip 191 2 core ( copper ) 192 2 core 2.5 sq. mm. 193 2 core 4 sq. mm. 194 2 core 6 sq. mm. 195 2 core 10 sq. mm. 196 2 core 16 sq. mm. 197 2 core 25 sq. mm. 198 3 core ( copper ) 199 3 core 2.5 sq. mm. 200 3 core 4 sq. mm. 201 3 core 6 sq. mm. 202 3 core 10 sq. mm. 203 3 core 16 sq. mm. 204 3 core 25 sq. mm. 205 4 core ( copper ) 206 4 core 4 sq. mm. 207 4 core 6 sq. mm. 208 4 core 10 sq. mm. 209 4 core 16 sq. mm. 210 4 core 25 sq. mm. 211 4 core 35 sq. mm. 212 4 core 50 sq. mm. 213 4 core 70 sq. mm. 214 armoured round cables ( copper ) 215 supplyinginsulated, galvanised steel formed wire armoured ( round ) cable 1100 v, copperconductor complete 216 xlpe armouredround cable 217 2 core ( copper ) 218 2 core 2.5 sq. mm. 219 2 core 4 sq. mm. 220 2 core 6 sq. mm. 221 2 core 10 sq. mm. 222 2 core 16 sq. mm. 223 2 core 25 sq. mm. 224 3 core ( copper ) 225 3 core 2.5 sq. mm. 226 3 core 4 sq. mm. 227 3 core 6 sq. mm. 228 3 core 10 sq. mm. 229 3 core 16 sq. mm. 230 3 core 25 sq. mm. 231 4 core ( copper ) 232 4 core 4 sq. mm. 233 4 core 6 sq. mm. 234 4 core 10 sq. mm. 235 4 core 16 sq. mm. 236 4 core 25 sq. mm. 237 4 core 35 sq. mm. 238 4 core 50 sq. mm. 239 4 core 70 sq. mm. 240 frxlpe armouredround 241 2 core ( copper ) 242 2 core 2.5 sq. mm. 243 2 core 4 sq. mm. 244 2 core 6 sq. mm. 245 2 core 10 sq. mm. 246 2 core 16 sq. mm. 247 2 core 25 sq. mm. 248 3 core ( copper ) 249 3 core 2.5 sq. mm. 250 3 core 4 sq. mm. 251 3 core 6 sq. mm. 252 3 core 10 sq. mm. 253 3 core 16 sq. mm. 254 3 core 25 sq. mm. 255 4 core ( copper ) 256 4 core 4 sq. mm. 257 4 core 6 sq. mm. 258 4 core 10 sq. mm. 259 4 core 16 sq. mm. 260 4 core 25 sq. mm. 261 4 core 35 sq. mm. 262 4 core 50 sq. mm. 263 4 core 70 sq. mm. 264 note all cables shall be isi marked polycab / havells / rr / kei and branded company 265 cables enclousers 266 supplyingg.i. pipe ‘a’ class 25 mm dia.for enclosingcable on wall / pole as per specification no. cb ce 267 25 mm 268 40 mm 269 50 mm 270 75 mm 271 supplying outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface. 272 50 mm 273 75 mm 274 90 mm 275 120 mm 276 146 mm 277 160 mm 278 175 mm 279 200 mm 280 note all the dwc pipes shall be isi marked. 281 cable glands 282 supplyingsingle compression type brass cable glandsfor xlpe armoured cable. 283 for 2 to 4 core 2.5 sq mm / 2 to 4 core 4 sq mm / 2 core 6 sq mm 284 for 3 to 4 core 6 sq mm / 2 to 4 core 10 sq mm 285 for 3 to 4 core 16 sq mm / 3 to 4 core 25 sq mm / 3 core 35 sq mm 286 for 4 core 35 sq.mm. / 3 core 50 sq.mm. 287 for 4 core 50 sq mm 288 for 3½ core 70 sq mm 289 for 3½ core 95 sq mm 290 for 3½ core 120 sq mm 291 for 3½ core 150 sq mm 292 for 3½ core 185 sq mm 293 3½core 240 sq mm 294 3½core 300 sq mm 295 3½core 400 sq mm 296 supplyingflange type glands brass cable glandsfor xlpe armoured cable. 297 for 2 to 4 core 2.5 sq mm / 2 to 4 core 4 sq mm / 2 core 6 sq mm 298 for 3 to 4 core 6 sq mm / 2 to 4 core 10 sq mm 299 s for 3 to 4 core 16 sq mm / 3 to 4 core 25 sq mm / 3 core 35 sq mm 300 for 4 core 35 sq.mm. / 3 core 50 sq.mm. 301 for 4 core 50 sq mm 302 for 3½ core 70 sq mm 303 for 3½ core 95 sq mm 304 for 3½ core 120 sq mm 305 for 3½ core 150 sq mm 306 for 3½ core 185 sq mm 307 3½core 240 sq mm 308 3½core 300 sq mm 309 3½core 400 sq mm 310 street light boxes & cable indicators 311 terminal box on pole 312 crca sheet 313 supplying water tight terminal box of 1.6 mm ( 16 gauge ) crca sheet 314 size 200 x 150 x 150 mm 315 size 300 x 200 x 150 mm 316 size 150 x 100 x 100 mm 317 cast iron box 318 supplyingwater tight terminal box of cast iron 319 size 200 x 150 x 150 mm 320 size 300 x 200 x 150 mm 321 size 150 x 100 x 100 mm 322 frp box 323 supplying frp box 324 size 150mm x 125mm x 100 mm, 325 size 250mm x 200mm x 100 mm 326 size 300mm x 200mm x 125 mm 327 cable lugs ( copper ) 328 supplyingcrimping type copper lugs for cable complete as per specification no. cb cl / cu 329 16 sq.mm 330 25 sq.mm 331 35 sq.mm 332 50 sq.mm 333 70 sq.mm 334 95 sq.mm 335 120 sq.mm 336 150 sq.mm 337 185 sq.mm 338 240 sq.mm 339 300 sq.mm 340 400 sq.mm 341 cable lugs ( alumium ) 342 supplyingcrimping type copper lugs for cable complete as per specification no. cb cl / cu 343 16 sq.mm 344 25 sq.mm 345 35 sq.mm 346 50 sq.mm 347 70 sq.mm 348 95 sq.mm 349 120 sq.mm 350 150 sq.mm 351 185 sq.mm 352 240 sq.mm 353 300 sq.mm 354 400 sq.mm 355 pvc amourmed cable aluminium 356 supplyinginsulated, pvc galvanised steel formed wire armoured aluminiumcable 1100 v, copperconductor complete 357 2 core 2.5 sq. mm. 358 2 core 4 sq. mm. 359 2 core 6 sq. mm. 360 2 core 10 sq. mm. 361 2 core 16 sq. mm. 362 2 core 25 sq. mm. 363 3 core 364 3 core 2.5 sq. mm. 365 3 core 4 sq. mm. 366 3 core 6 sq. mm. 367 3 core 10 sq. mm. 368 3 core 16 sq. mm. 369 3 core 25 sq. mm. 370 4 core 371 4 core 4 sq. mm. 372 4 core 6 sq. mm. 373 4 core 10 sq. mm. 374 4 core 16 sq. mm. 375 4 core 25 sq. mm. 376 4 core 35 sq. mm. 377 4 core 50 sq. mm. 378 4 core 70 sq. mm. 379 pvc amourmed cablecopper 380 supplyinginsulated, pvc galvanised steel formed wire armoured coppercable 1100 v, copperconductor complete 381 2 core 2.5 sq. mm. 382 2 core 4 sq. mm. 383 2 core 6 sq. mm. 384 2 core 10 sq. mm. 385 2 core 16 sq. mm. 386 2 core 25 sq. mm. 387 3 core 388 3 core 2.5 sq. mm. 389 3 core 4 sq. mm. 390 3 core 6 sq. mm. 391 3 core 10 sq. mm. 392 3 core 16 sq. mm. 393 3 core 25 sq. mm. 394 4 core 395 4 core 4 sq. mm. 396 4 core 6 sq. mm. 397 4 core 10 sq. mm. 398 4 core 16 sq. mm. 399 4 core 25 sq. mm. 400 4 core 35 sq. mm. 401 4 core 50 sq. mm. 402 4 core 70 sq. mm. 403 note all cables shall be isi marked polycab / havells / rr / kei and branded company 404 timer switch 405 supplying single phase, astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, etc for automatic operation 240v, street light control panel up to the max load of 6kw, spn mcb 40a. 406 supplying single phase, astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, etc for automatic operation 240v, street light control panel up to the max load of 12kw, spn mcb 63a. 407 supplying threephase, astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, etc for automatic operation 415v, street light control panel up to the max load of 6kw, spn mcb 40a. 408 supplying single phase, astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, etc for automatic operation 415v, street light control panel up to the max load of 12kw, spn mcb 63a. 409 supplying astronomical adjustable programmable timerwith minimum 5 years battery back up, having ip54, ik10 protection, 2 pole contactor up to 60 a for single phase 2 wire system. 410 supplying astronomical adjustable programmable timerwith minimum 5 years battery back up, having ip54, ik10 protection, 2 pole contactor up to 60 a for three phase 4 wire system. 411 power contactor 412 lt contactor 12 amp three phase ltlk make 413 lt contactor 16 amp three phase ltlk make 414 lt contactor 32 amp three phase ltlk make 415 lt contactor 40 amp three phase ltlk make 416 lt contactor 63 amp three phase ltlk make 417 lt contactor 70amp three phase ltlk make...

Directorate Of Municipal Administration - Maharashtra

40430596 supply of electrical materials for the financial year 2023 24 under chakan nagar parishad electricity department 1 supplying & erecting crimping type copper lugs for cable up to 16 sq. mm. complete as per specification no. 2 supplying & erecting crimping type aluminium lugs for cable up to 16 sq. mm. complete as per specification no. cb cl / al 3 supplying & erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wgma / bw 4 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or anyother places. as per specification no: wg ma / bw 5 supplying, erecting & terminating xlpe armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no.cb lt / al ( 6 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire. 7 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. 8 supplying, erecting & terminating xlpe armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no.cb lt / al 9 supplying, erecting & terminating xlpe armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 10 supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block / pvc junction box 11 supplying and erecting pvc trunking ( pvc casing n capping ) of size 25mm with accessories on wall / ceiling as per specification no: wg ma / con. 12 supplying and erecting pvc trunking ( pvc casing n capping ) of size 32mm with accessories on wall / ceiling as per specification no: wg ma / con. 13 supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. 14 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ classinsulation. 15 supplying pedestal fan 400 mm. 230 volts 50 cycles oscillating type completewith guard and regulator 3 meter. of flexible wire and hand shield type 3 pin plugtop. 16 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375 / 380mm. 1400 rpm complete erected in position as per specification no. fg fn / exf 17 supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles1200 mm, max. energy consumption of 28w having service ratio ( cmm / w ) of min. 8 , pf>0.9, thd<10% with ir remote control / compatible speedregulator, temperature rise of max. 40 deg. c, having external mounted controlpcb completely erected in position as per specification no. fg fn / cf 18 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th 19 supplying and erecting electronic type driver for outdoor led fittings 26w 45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and t 20 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 21 supplying & erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600mah lithium ion battery with charging time of 8 10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100lumen / watt, cri>80, cct of 6500k and thd<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty 22 supplying and erecting anodized aluminium corridor / passage light led fitting ( 4 feet ) max. 22w with high transitivity diffuser with system lumens output of min.2200 lumens , min. efficacy of 100 lumen / w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%, thd<10%, p.f. >0.95, operating range of 200 270v, surge protection of 2 kv, life class of 50, 000 hrs. at l70b50, including driver, with end caps on provided pvc block / wooden board with 3 years warranty. 23 supplying and erecting led square / circular max. 18 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuserhaving system lumens output of min. 2000 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of5%, thd<10%, p.f. >0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 24 supplying and erecting integrated led street light fitting 40 to 50w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3 years warranty as per specification no fg odf / fls2. 25 supplying & erecting integral post top lantern fixtures ( light house type ) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole / bracket as per specification no. fg odf / ptl 26 supplying and erecting isi mark modular type switch 16a dulyerected on provided plate and box with wiring connectionscomplete. 1 8 2 27 supplying and erecting modular type 3 pin 6 / 16a multi socket with safetyshutter, duly erected on provided plate and box with wiring connectionscomplete. 28 supplying and erecting pvc surface modular switch box with doublemounting plate for 12 module duly erected. 29 supplying and erecting single pole and neutral distribution board ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb 30 supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching ?on? & switching ?off? street light as per daily sunsetand sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs battery backup and manual over drive facility capable to drive different capacitycontactors timer erected in provided m.s. box in an approvedmanner. 31 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, withnecessary materials 32 supplying and erecting two pole power contactor 230 v, 32 a for time switchcomplete erected on provided wooden block / box, with necessary materials. 33 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 34 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 35 supplying and erecting cupboard for enclosing switchgears or for any other purpose made from selected marine plywood planks 19 mm thick duly varnished / painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. cupboard shall be dulygrouted with suitable size of iron work in wall at the bottom. ( size of cupboard shall be specified in the estimate ) 36 epoxy painting on both side of approved colour shade of provided iron work / ms / crca sheet steel work complete along with anti rust treatment complete. 37 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mmdia. g.l. rod complete with all materials as per specification no. 38 supplying and erecting porcelain base iron clad cut out hc type 415v, 100aerected on polished wooden block. 39 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 40 supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersibletype copper cable suitably clamped at fixed intervals with column pipe assemblycomplete. 41 supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycleswith overload element with necessary materials and connected to supply up to 3h.p. 42 supplying & erecting automatic control panel for 3 ph, 415 volt, a.c.submersible / centrifugal pump set up to 7.5 hp 10 h.p. consisting of dolstarter having relay range 13 21 amp, s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phasereversal, phase imbalance etc. 43 supplying & erecting minimum three & above star rated centrifugal water pump ( monoblock ) , 230v, single phase 50 cycles a.c. supply of 1.125kw / 1.5hp with discharge 198 / 50 litres per minute ( lpm ) ) for head of 15 / 37.5 m & 40 mm suction / 32 mm delivery pipe on provided c.c.foundation as per specification no. wp cgp 44 providing annual comprehensive maintenance contract for 1.5tr split / window air conditioning unit complete as per terms and conditions. jobincludes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within24 hours 4 ) sending standby manpower for vip movement. the job exclude sheetmetal work and plastic material. 45 carrying out servicing of dg set up to 50 kva with / without amf panel of any make to ensure smooth running of dg set for 30 mins on load. checking abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking v belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning ofradiator and leakage testing checking of radiator & fuel supply hose pipes, checking of avr, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, cleaning of dg set internally using blower, cleaning radiator, attending breakdowns as and when required during one month period or during vip visit within 2 hours of intimation and submit the servicing report to engineer in charge. ( non comprehensive ) as perspecification no. gen ser amc 46 providing vehicle mountedhydraulic ladder on hour basis with transportation , fuel and driver operator 47 providing electrical grinder machine with wheel / disc for cutting wood , metal, brick etc 48 electric drill machine with tool kit 49 mnx 9 40amp contactor operating coil 50 mnx 50 80amp contactor operating coil 51 supplying and erecting 1 phase 2 core 16 sq.mm. ( 1x16+1x25 ) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl / abc 52 foundation plate, bolt as per requirement 53 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp. 54 providing pair of duly tested rubber hand gloves as per is :47705 suitable for working up to 22 kv supply complete. 55 supplying standard first aid box with necessary antiseptic cream, medicine foruse on wounds due burn, crepe bandage, gauge bandage, medicated ready to usebandage ( band aid ) adhesive tape for medicinal use, scissors, anti septic solution, etc. ( all above contents shall be of standard makes ) 56 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cmdeep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishingcomplete. ( above 6 m to 9 m poles ) 57 making cement concrete foundation in 1:3:6 cement concrete, ( 20 to 25 ) mm.stone metal duly plastered with necessary curing for complete. ( pole muffing orany other purpose ) . 58 providing, commissioning and maintaining additional ip based 2.0 mp, full hd, ir ip ptz camera in existing cctv system with necessary mains, switchgears on hire basis for one day. 59 providing temporary illumination consisting of flood light fitting 200 w complete led fitting with lamp, complete required switchgear erected and dismantled without using scaffolding upto three days. 60 providing and maintaining temporary cordless ( hand type or lape type ) super sensitive huf microphone ( 1 no stand by ) for one day. 61 providing, maintaining and operating temporarypublic address system on hire consisting 02 nos. solid state heavy wattage amplifier 250 watts ( one for working and another for stand by emergency ) working on ac / generator and 24 volt car battery supply, 06 nos. of matching of 100 volt line ( 200 watts ) box type speakers / sound column, 02 nos super sensitive microphone with suitable size of microphone holding stand.the system shall be in a fully automatic change over operation in case of failure of supply for one day. 62 hiring charges for supplyingand maintaining 230v, 50 cycles ac generatingset1 to 2 kva capacity with necessaryfuel, mains, switchgears and accessories complete with continuousrunning onload / no load as per requirements completewith self certification. 63 hiring charges for supplyingand maintaining 230 / 415 v, 50 cycles acgenerating set3 to 10 kvacapacity with necessaryfuel, mains, switchgears and accessories complete with continuousrunning onload / no load as per requirements completewith self certification. 64 hiring charges for supplyingand maintainingtemporary415v, 50cyclesacgenerating set 11 to 25 kva ( excluding 25 kva ) capacity with necessaryfuel, mains, switchgears and accessories complete with continuousrunning onload / no load as per requirements completewith self certification. 65 providing temporary illumination consisting of white / colour series lights 50 nos. with miniaturelampsof 6.2 to 16v with required switchgears erected and dismantled with rotor effect as approved without scaffolding upto three days. 66 providing temporary illumination consisting of led rope light having 2 to 5 w capacity per meter and consisting suitable power adaptor with mains, switchgears erected and dismantled with using scaffolding and maintaining the same upto 3 days...

Directorate Of Municipal Administration - Maharashtra

39935885 tender for vadgaon all motor rate list 23 24 1 repairing work for 15 hp submersible motor & pump at sanskruti wtp, sangvi jackwell, vadgaon maval. 2 dismantling & erection of 15 hp karwel make submersible motor & transporation fromsite workshop & return etc. complete 3 complete rewinding of motor with quality copper ‘ f ’ clamp insulation& skilled labour charge etc. 4 b ) rotter balancing 5 c ) motor bush top 6 d ) motor bush bottom 7 e ) thrust plate top & bottom 8 f ) pump shaft sleeve s / s 9 g ) pump shaft s / s ( new ) 10 h ) pump shaft balance 11 i ) pump impeller 12 j ) impeller neck ring 13 k ) impeller balance 14 l ) impeller diffuser 15 m ) oil seal & mechanical seal 16 n ) coupling bush 17 o ) n.r.v.rubber 18 p ) o ring 19 q ) nut bolts 20 r ) pump bush 21 s ) 25 sqmm cable 22 t ) waterproof joint kit 23 repairing work for 30 hp submersible motor & pump at jambhul jackwell, vadgaon maval. 24 dismantling & erection of 30 hp karwel make submersible motor & transporation fromsite workshop & return etc. complete 25 complete rewinding of motor with quality copper ‘ f ’ clamp insulation& skilled labour charge etc. 26 b ) rotter balancing 27 c ) motor bush top 28 d ) motor bush bottom 29 e ) thrust plate top & bottom 30 f ) pump shaft sleeve s / s 31 g ) pump shaft s / s ( new ) 32 h ) pump shaft balance 33 i ) pump impeller 34 j ) impeller neck ring 35 k ) impeller balance 36 l ) impeller diffuser 37 m ) oil seal & mechanical seal 38 n ) coupling bush 39 o ) n.r.v.rubber 40 p ) o ring 41 q ) nut bolts 42 r ) pump bush 43 s ) 25 sqmm cable 44 t ) waterproof joint kit 45 repairing work for 52 hp submersible motor & pump at katvi jackwell, vadgaon maval. 46 dismantling & erection of 52 hp karwel make submersible motor & transporation fromsite workshop & return etc. complete 47 complete rewinding of motor with quality copper ‘ f ’ clamp insulation& skilled labour charge etc. 48 b ) rotter balancing 49 c ) motor bush top 50 d ) motor bush bottom 51 e ) thrust plate top & bottom 52 f ) pump shaft sleeve s / s 53 g ) pump shaft s / s ( new ) 54 h ) pump shaft balance 55 i ) pump impeller 56 j ) impeller neck ring 57 k ) impeller balance 58 l ) impeller diffuser 59 m ) oil seal & mechanical seal 60 n ) coupling bush 61 o ) n.r.v.rubber 62 p ) o ring 63 q ) nut bolts 64 r ) pump bush 65 s ) 25 sqmm cable 66 t ) waterproof joint kit 67 repairing work for 62 hp submersible motor & pump at sangvi jackwell, vadgaon maval. 68 dismantling & erection of 62 hp karwel make submersible motor & transporation fromsite workshop & return etc. complete 69 complete rewinding of motor with quality copper ‘ f ’ clamp insulation & skilled labour charge etc. 70 b ) rotter balancing 71 c ) motor bush top 72 d ) motor bush bottom 73 e ) thrust plate top & bottom 74 f ) pump shaft sleeve s / s 75 g ) pump shaft s / s ( new ) 76 h ) pump shaft balance 77 i ) pump impeller 78 j ) impeller neck ring 79 k ) impeller balance 80 l ) impeller diffuser 81 m ) oil seal & mechanical seal 82 n ) coupling bush 83 o ) n.r.v.rubber 84 p ) o ring 85 q ) nut bolts 86 r ) pump bush 87 s ) 25 sqmm cable 88 t ) waterproof joint kit 89 repairing work for 100 hp vt pump set at jambhul jackwell, vadgaon maval. 90 dismantling & erection of 100 h.p.v.t. pump set with bowl assembly, discharge head, column pipe, shaft, bearing bushing with vt pump s.v.& reflex valves & allied equipments & transportion from site to workshop &return etc. 91 repairing of v.t. pump with required following spares with skilled labour charge etc. 92 a ) stuffing box bronze bushing 93 b ) gland sleeve s / s material 94 c ) top bowl repair with providing & welding of m.s. flange heavy duty with required sundry etc. 95 d ) column pipe repair with welding if ribs m.s. flange with machining etc. 96 e ) sypder rubber bush 97 f ) shaft s / s material ( 4 mtr ) 98 g ) column shaft s / s material ( 1.5 mtr ) 99 h ) shaft sleeve s / s material 100 providing & fixing special strengthening heavy duty nut bolts 101 a ) rubber packing ( champion ) 102 b ) neck ring brass 103 c ) bowl bush rubber 104 d ) bowl bush brass 105 e ) bowl turning & surface counter top & bottom 106 f ) impeller 107 g ) impeller qualate 108 h ) impeller qualate check nut 109 i ) impeller turning 110 j ) spider bushing 111 k ) impeller neckring 112 l ) gland slive 113 m ) gland housing bush 114 bowl assembly fitting 115 complete servicing of 100 h.p.vt pumpwith checking earth insulation, winding, balancing etc. 116 tafflon gland 117 repairing & rewinding work for 162 hp motor at jambhul jackwell, vadgaon maval. 118 dismantling & erection of 162 hp motor & transporation fromsite workshop & return etc. complete 119 complete rewinding of motor with quality copper ‘ f ’ clamp insulation including air drying, varnishing, backing & skilled labour charge etc. 120 motor stamping repairing works 121 b ) motor cooling fan 122 c ) rotter balancing 123 d ) best quality grease ap3 124 e ) 40 no. bearing oil 125 f ) motor top bearing 126 g ) motor bottam bearing 127 h ) motor top & bottam busing, turning oil seal 128 i ) oil seal 129 j ) motor lock ratchet check nut lock key 130 k ) brass pipes & nipples. 131 l ) bearing check nut 132 m ) ratchet bush key with lock nut 133 n ) motor housing cover top 134 o ) motor housing cover bottom 135 p ) motor cannection plate 136 q ) motor cannection lugs. 137 r ) cable 1 } 3.3 kv pvc armoured 3 core 50sq.mm 138 2 } pvc 3.3 kv armoured70sq.mm 139 3 } pvc 3.3 kv armoured 95 sq.mm 140 repairing work for 162 hp vt pump set at jambhul jackwell, vadgaon maval. 141 dismantling & erection of 162 h.p.v.t. pump set with bowl assembly, discharge head, column pipe, shaft, bearing bushing with vt pump s.v.& reflex valves & allied equipments & transportion from site to workshop &return etc. 142 repairing of v.t. pump with required following spares with skilled labour charge etc. 143 a ) stuffing box bronze bushing 144 b ) gland sleeve s / s material 145 c ) top bowl repair with providing & welding of m.s. flange heavy duty with required sundry etc. 146 d ) column pipe repair with welding if ribs m.s. flange with machining etc. 147 e ) sypder rubber bush 148 f ) shaft s / s material ( 4 mtr ) 149 g ) column shaft s / s material ( 1.5 mtr ) 150 h ) shaft sleeve s / s material 151 providing & fixing special strengthening heavy duty nut bolts 152 a ) rubber packing ( champion ) 153 b ) neck ring brass 154 c ) bowl bush rubber 155 d ) bowl bush brass 156 e ) bowl turning & surface counter top & bottom 157 f ) impeller 158 g ) impeller qualate 159 h ) impeller qualate check nut 160 i ) impeller turning 161 j ) spider bushing 162 k ) impeller neckring 163 l ) gland slive 164 m ) gland housing bush 165 bowl assembly fitting 166 complete servicing of 162 h.p.vt pumpwith checking earth insulation, winding, balancing etc. 167 tafflon gland 168 control panel , soft starter, fuse, mcb 169 control panel 170 3 hp 171 5 hp 172 15 hp 173 60 hp 174 75 hp 175 180 hp 176 fcma / hfsr electrical soft starter 177 3 hp 178 5 hp 179 15 hp 180 60 hp 181 75 hp 182 180 hp 183 star delta starter 184 3 hpdol starter 185 5 hpdol starter 186 15 hp 187 60 hp 188 75 hp 189 180 hp 190 repairs of stardelta starter 191 3 hp dol starter 192 5 hp dol starter 193 15 hp 194 60 hp 195 75 hp 196 180 hp 197 per star delta starter with contract 198 starter relay 199 novold coil 200 star delta starter contact speak kit 201 hrc fuse 202 60 amp 203 80 amp 204 100 amp 205 125 amp 206 150 amp 207 200 amp 208 starter contactor 209 l&t make mnx 9 210 l&t make mnx 12 211 l&t make mnx 16 212 l&t make mnx 18 213 l&t make mnx 25 214 l&t make mnx 32 215 l&t make mnx 40 216 l&t make mnx 140 217 l&t make mnx 185 218 stardeltatimer 219 220 volts 220 time switch timer 221 overload relay 222 relay range 4 to 6 amp 223 relay range 9 to 14 amp 224 relay range 13 to 21 amp 225 relay range 45 to 75 amp 226 mcb 227 25 amp 415 volt mark 228 32 amp 415 volt isi mark 229 40 amp 415 volt isi mark 230 63 amp 415 volt isi mark 231 125 amp 415 volt isi mark 232 200 amp 415 volt isi mark 233 changeover switch 234 25 amp 415 volt mark 235 32 amp 415 volt isi mark 236 40 amp 415 volt isi mark 237 63 amp 415 volt isi mark 238 125 amp 415 volt isi mark 239 200 amp 415 volt isi mark 240 8mm...

Smart City Development Corporation Limited - Maharashtra

39895818 tender for sant tukaram natyagruh electrical work 1 supplying and laying rigid steel conduit 16 swg 25 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no: wgma / cc. ( 1 1 4 ) 2 supplying and erecting hms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc ( 1 1 9 ) 3 supplying and layinghms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc ( 1 1 10 ) 4 supplying and erecting hms pvc conduit frls grade25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. ( 1 2 4 ) 5 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 1 ) 6 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw ( 1 3 2 ) 7 supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 7 ) 8 supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. ( 1 6 1 ) 9 supplying and erecting modular type switch 16aduly erected on provided plate and box with wiring connections complete. ( 1 6 2 ) 10 supplying and erecting modular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 10 ) 11 supplying and erecting modular type 3 pin 6 / 16amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 11 ) 12 supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. ( 1 6 14 ) 13 supplying and erecting modular type telephone socket one gangwith safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 15 ) 14 supplying and erecting modular type computer jack rj45 with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 17 ) 15 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. ( 1 6 23 ) 16 supplying and erecting modular type blanking plate two module, duly erected on provided plate & box. ( 1 6 25 ) 17 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 35 ) 18 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 36 ) 19 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 37 ) 20 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 38 ) 21 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 39 ) 22 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 40 ) 23 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background ( 1 6 41 ) 24 point wiring for light / bell / exhaust fan in 20 mm frls grade hms pvcconduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw. ( 1 7 12 ) 25 point wiring for ceilingfan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw ( 1 7 13 ) 26 point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw ( 1 7 14 ) 27 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modulartype switch, earthing and required accessories as per specification no: wgpw / hw ( 1 7 15 ) 28 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / hw 29 wiring for plug on board withswitch socket surface / concealed type, copper wiring and earthing and with modular accessories as per specification no: wg pw / cw ( 1 7 26 ) 30 supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 1 ) 31 supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 7 ) 32 supplying and erecting 15m vga cord low voltage gradeto be laid in provided conduits and terminating with male / female vga connectors complete. ( 1 8 20 ) 33 supplying, erecting and commissioning ofmdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw ( 1 9 1 ) 34 supplying and installingexpansion cabinet for extension of digital hybrid epabx to expand system by 32 ports with programming and configuration of extensions and direct lines with required accessories complete. ( 1 9 33 ) 35 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc ( 1 10 1 ) 36 supplying, fixing, and configuring8 ports managed gigabit, layer 2 switch, 10 / 100 / 1000 base t, poe smart switch plus 2 sfp erected in provided rack complete. ( 1 11 2 ) 37 supplying, installing & testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. ( 1 12 1 ) 38 supplying and fixing42 u floormount server rack ( dimension dxwxh – 800x1000x2070 mm ) as per specification no. wg nas / rak ( 1 12 29 ) 39 supplying and erecting led square / circular max. 18 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 5 ) 40 supplying and erecting led square / circular max. 25 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 6 ) 41 supplying and erecting ledpanel light ( 600mm x 600mm ) max. 35 whaving crca powder coated housing, polystyrene diffuser havingsystem lumens output of min 4200 lumens, min. efficacy of 120 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 8 ) 42 supplying and erecting anodized aluminium corridor / passage light led fitting ( 4 feet ) max. 22wwith high transitivity diffuser withsystem lumens output ofmin.2200 lumens , min. efficacy of 100 lumen / w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%, thd<10%, p.f. >0.95, operating range of200 270v, surge protection of 2 kv, life class of 50, 000 hrs. at l70b50, including driver, with end caps on provided pvc block / wooden board with 3 years warranty. ( 2 1 18 ) 43 supplying and erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8 10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen / watt, cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. ( 2 1 22 ) 44 supplying and erecting uv fly killer / bug catcher light fittinghaving 2 x 20w uv tube lights to cover min. area of 500 sq.ftwith powdered coated m.s. / steel body suitable to work on 230v, ac supply having top mounting arrangement with ss chain complete and 3 core 1 mtr. flexible wire with 1 year warranty. ( 2 1 23 ) 45 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block / sunmica block of suitable size. ( 2 3 13 ) 46 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. ( 2 10 15 ) 47 supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of28w having service ratio ( cmm / w ) of min. 8 , pf>0.9, thd<10% with ir remote control / compatible speed regulator, temperature rise of max. 40 deg. c, having external mounted control pcb completely erected in position as per specification no. fg fn / cf ( 2 10 22 ) 48 supplying and fixinganchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. ( 2 11 2 ) 49 supplying and erecting fan clamp of 30 x 5 mm. m.s. flat of required length and 10 mm.m.s. bolt and nuts erected with necessary hook of 10 mm. m.s. round bar and painted. ( 2 11 3 ) 50 supplying and erecting ‘b’ class g.i .pipe / m.s. pipe down rod duly painted for fan complete erected with pvc three core flexible cable 1 sq. mm copper pvc wire. ( 2 11 6 ) 51 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. ( 2 11 11 ) 52 supplying and erecting 20 swg g.i sheet metal cawl rectangular / round shaped with 25 x 25x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no fg fas / msc ( 2 11 17 ) 53 supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh / 24hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections ( i.e. thermostat & thermalfunctioncut out, valve ) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh / stwh ( 3 1 2 ) 54 supplying, erecting, testing and commissioning ofself contained water cooler 230 / 250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap wcr / wc ( 3 3 10 ) 55 supplying, installing, testing and commissioning of10kva capacity onlinepure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protectionsas per specification no. ap ups ( 3 7 6 ) 56 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 57 supplying and erecting on load four pole automatic transfer switch, 415v, 400a, 50 hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ats controller with provision of time delay protection of ov, uv, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to is / iec 60947 3 part 1 / 6 . ( 5 1 14 ) 58 supplying, erectingandmarking spmcb 6a to 32a, c serieswith rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 2 ) 59 supplying, erectingandmarking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) 60 supplying, erectingandmarking spmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 5 ) 61 supplying, erectingandmarking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 7 ) 62 supplying, erectingandmarking dpmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 8 ) 63 supplying, erectingandmarking tpmcb 6a to 32a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 10 ) 64 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 65 supplying and erecting triplepole and neutral distribution board ( tpndb ) , sp / tp mcbs total 4 ways / 12 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 4 ) 66 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 8 ways / 24 poles, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 5 ) 67 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 12 ways / 36 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / giframe ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 6 ) 68 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 6 ways ( 6 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 8 ) 69 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 9 ) 70 providing and erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and fixed magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 1 ) 71 providing and erecting 3 pole mccb 415v, 250a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 3 ) 72 providing and erecting 3 pole mccb 415v, 400a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustablethermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 4 ) 73 providing and erecting 3 pole mccb 415v, 630a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 5 ) 74 providing and erecting 3 pole mccb, 415v, 800a, rated short circuit breaking capacity 50 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 6 ) 75 supplying, fixing, and commissioning 4 polercbo 6 / 10 / 16 / 20 / 25a, with overcurrent, rated short circuit breaking capacity ( 10 ka ) and earth leakage protection, with 30 / 100 / 300 ma sensitivity and short circuit and earth leakage trip indications per specification no sw rccb / rcbo ( 5 6 12 ) 76 supplying, installing, testing and commissioning ofair circuit breaker manual fixed type, non drawout type, 650v, 1000a rated at 50º c without deration, 12kv impulse, 4 pole ( 100% neutral protection ) , 50 ka ( ics=icu=icw for 1s ) , with standard accessories with ready to close, individual fault trip, alarm and tripindication, mechanical and electrical anti pumping, soft / hard rating plug ( including hard rating plug ct ) with micro processer based lcd display release with lsig and temperature rise protection & with 4 c / o contacts for on off trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. sw swr / acb ( 5 8 3 ) 77 supplying and erecting metal work in crca sheet including iron work for supportswith fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. ( 6 1 1 ) 78 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 79 supplying and erecting 250 kvar, 3 phase, 50 hz., power contactors derated for microprocessor apfc controller with mpp / app type capacitor with 525 v and having minimum overcurrent capacity of 1.8 in, peak inrush current capacity 300 inand minimum life 150000 hours with , consisting of suitable steps of mpp / app type capacitor unitswith detuned aluminium filter 7% reactors with circuit breaker as main incomer and mccb for each branch protection, as per specification no cp ed / apfc ( 6 7 17 ) 80 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 81 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 82 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 83 supplying, erecting & terminating fr xlpe insulated, galvanised steel formedwire armoured ( strip ) cable 1100 v, 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 84 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 85 supplying and erecting g.i. pipe ‘a’ class75 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 4 ) 86 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 200 mm width & 20 mm height complete with necessary hardware. ( 7 11 12 ) 87 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 500 mm width & 20 mm height complete with necessary hardware. ( 7 11 15 ) 88 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 89 supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and / or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no ea ep. ( 9 2 1 ) 90 supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. ( 9 3 1 ) 91 providing and back filling ground enhancing compound 25 kg bag complete. ( 9 3 2 ) 92 supplying, installation and testing of maintenance free earthing comprising ofelectrode of 17.2 mm diameter low carbon steel with 250 micron molecularcopper bonded earthing rod of length 3m along with 25 kg carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity complete, and recording the resultsspecification no. ea mobi ( 9.1.5 ) 93 supplying, erecting, testing and commissioning3 10 watt smart wired led ceiling lamp downlighter wiz connected ( shades of white / warm white + dimmable + pre set modes ) ( non csr ) 94 supplying, erecting, testing and commissioning of wall / floor mounted three phase 415 v electronic dimmer 12x4 kw having rectangular shape semi automatic / dmx type, with ryb indicator, having 24 input jackwith crca housing min 22 gauge with all internal mcb, wiring, controlling accessories complete ( non csr ) 95 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) 96 supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 6600 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg odf / fls2. ( 2 4 5 ) 97 supplying and erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation . ( 5 2 5 ) 98 supplying, erecting & marking spmcb 0.5a to 5a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 1 ) 99 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 100 supplying & erecting triple pole and neutral distribution board ( tpndb ) , 3 pole / 4 pole mccb as incomer & outgoing sp mcb ( 12 poles ) or tp mcb of 4 ways ( 12 poles ) , with door, 1.2mm thickness, surface / flush mounted, on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb1 ( 5 4 15 ) 101 supplying and erecting gi sheet 1.6mm ( 16 swg ) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in marathi, hindi and english erected at position for hv / ehv ( 11000 volts ) installation with compliance to is 2551 1982 ( 6 1 16 ) 102 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 103 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 27 ) 104 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 30 ) 105 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 106 providing and erecting 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl ( 8 2 12 ) 107 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl / pbkt ( 8 2 21 ) 108 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep ( 9 1 1 ) 109 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 110 supplying and erecting gi strip of high purity required size used for earthing on wall and / or any other purpose with necessary gi clampsfixed on wall painted with bituminous paint with joints required. as per specification no ea ep. ( 9 2 3 ) 111 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 112 makingm 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . ( 16 3 9 ) 113 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 114 supplying, fixing, and commissioning mcb type change over switch 4 pole, 40a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos ( 5 3 25 ) 115 supplying and erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb / tp mcb / fp mcb / rccb / rcbo complete erected on angle iron / gi frame. ( 5 4 13 ) 116 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( 7 1 27 ) 117 supplying and erecting g.i. pipe‘a’ class 40 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 2 ) 118 supplying and laying ( including excavation ) of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. ( 7 6 9 ) 119 providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. covercomplete with all materials, testing & recording the results asper specification no. ea ep ( 9 1 3 ) 120 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 121 supplying and erecting minimum three & above star rated submersible pump set of 2.25 kw / 3 hp with 415 v, 50 c / s ac supply suitable for 100 mm dia. borewell suitable for 60 to 170 lpm discharge at 97 to 30 m head & discharge & delivery pipe of size 40 mm diameter with a necessary h type clamps as per specification no. wp smp 122 supplying and erecting minimum three & above star rated submersible pump set suitable for erection on open well of 5.625 kw / 7.5 hp with 415 v 50 c / s. a.c. supply, having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of suction 75 mm / delivery 65 mm diameter erected with necessary h type clamps as per specification no. wp osp ( 12 3 3 ) 123 supplying and erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 8 ) 124 supplying and erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 9 ) 125 supplying and erecting water level controller 230 / 415 v, a.c. , four way under ground & over head tank operation only. ( 12 4 15 ) 126 supplying & erecting pvc coated 5 mm dia. brass sensor / electrode duly wired with nuts & bolts complete ( set of 3 nos ) . ( 12 4 15 ) 127 supplying and erecting automatic control panel for 3 phase , 415 volt, a.c, submersible / centrifugal pump set up to 7.5 hp consisting of dol starter having relay range 9 14 amp, s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc . ( 12 4 17 ) 128 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. ( 16 1 5 ) 129 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 130 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw plb / gp. ( 16 5 6 ) 131 supplying and erecting isi mark gi pipe 75 / 80 mm dia. ‘b’ class at positionwith accessories complete. specification no. cw plb / gp. ( 16 5 8 ) 132 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet / submersible pump with required material complete. ( 16 5 18 ) 133 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. ( 16 6 15 ) 134 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. ( 16 6 21 ) 135 supplying and erectinghms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 1 1 9 136 supplying and laying hms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 1 1 10 137 supplying and erecting 25 mm dia. corrugated flexiblepolypropylene conduit 1 2 2 138 supplying and erecting 10m hdmi cord low voltage grademinimum 4k compliant to be laid in provided conduits with male / female 19 pin hdmi connectors complete.. 1 8 23 139 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc 1 10 1 140 supplying, fixing, and configuring 24 ports, poe switch in provided rack as perspecification no. wg nwc / ens ( 1 11 3 ) 141 supplying, installing and testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. 1 12 1 142 supplying and fixing 9u wall mount rack ( dimension dxwxh – 500x600x500 mm ) as per specification no. wg nas / rak1 12 18 143 supplying and fixing 24 ports light guide unloaded interconnect unit, wall mounted type, with adapter panel for termination of optical fibre cables onwall in provided u rack complete as per specification no. wg nas / liu 1 12 8 144 supplying, installing, testing and commissioning of2kva capacity online pure sine wave, with backup time of 03 hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups ( 3 7 2 ) 145 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 146 supplying, erecting, testing & commissioning 5 mp full ip dome camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 2.8mm@f2.0dori distance 42 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo max. resolution 2592 x 1944video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( include – 12 month fully compressive warranty ) ( rates are as per sanct.lt.no.431 dt.22.03..2022 ) ( non csr ) 147 supplying, erecting, testing & commissioning 5 mp full ip bullet camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 4.0mm@f2.0dori distance 60 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( non csr ) 148 supplying, erecting, testing & commissioningcamera nvr 32 channel system specifications :32ch with 4k real time live preview max 32q mbps incoming bandwidth with h.265 compression, decoding support upto 4 x 4k@30, 8 x 4mp@20 on vif version 2.4 conformance vca search and smart search for playback support 8 sata hdd up to 64tb with raid configuration, 2 usb 2.0, 1 usb. ( non csr ) 149 supplying and installation testing & commissioning of surveillance internal hdd ( hard disk drive ) internal hdd supply , installation testing and commissioning for surveillance hddrecording capacity 8tb. ( non csr ) 150 supplying, erecting, commissioning & testing screen ( 108 cm ) / 40 inchpecifications general o screen size : 108 cm ( 43 ) • screen type : led • hd technology & resolution : full hd tv, 1920 x 1080 • hdmi : 3, usb : 1 • launch year : 2018 onnectivity features : hdmi, 2 side : usb o 1 side video features • contrast ratio : mega contrast ( static ) • picture engine : hyper real • view angle : 178 degree • panel type : a+, digital noise filter : yes • led display type : direct • aspect ratio16:09 • refresh rateo 60 hz • other video features o pmi 300: clarity, color, contrast, active noise reduction, dynamic color enhancer o picture mode: 8 modes ( vivid, standard, aps, cinema, cricket, game, expert1, expert2 ) o picture: jpeg, digital noise reduction, movies support in usb mode, mpeg h.264 decoder o response time: 6.5 ms, still image, wide color enhancer ( plus ) , film mode, cricket mode audio features • number of speakers : 2 • speaker type: down firing with bass reflex • sound technology : dolby digital plus • speaker output rms : 20 w warranty • warranty summary : 1 year comprehensive and 1 year additional on panel. ( non csr ) ...

Military Engineer Services - Maharashtra

39768554 tender for provision of 06 nos security watch towers at hemrl, pune; 1 lumpsum price worked out by the contractor for construction of watch tower with rcc framed structure ( g+2 ) complete all as shown on drawings and as specified. 2 lump sum price worked out by the contractor for “site development, earthwork and excavation as listed in schedule ‘a’ part iirepresenting_______ % ______________ percent above / below the lump sum price of `10, 36, 344.72 inserted by the mes in schedule ‘a’ part ii 3 lump sum price worked out by the contractor for “internal electrification” as listed in schedule ‘a’ part iii representing__________ % ____________ percent above / below the lump sum price of `3, 98, 415.66 inserted by the mes in schedule ‘a’ part iii 4 lump sum price worked out by the contractor for “internal water supply” as listed in schedule ‘a’ part iv representing__________ % ____________ percent above / below the lump sum price of ?37, 495.56 inserted by the mes in schedule ‘a’ part iv 5 lump sum price worked out by the contractor for roads / paths / culverts” as listed in schedule ‘a’ part v representing______ % _________________ percent above / below the lump sum price of `4, 62, 888.00 inserted by the mes in schedule ‘a’ part v 6 lump sum price worked out by the contractor for external electric supply” as listed in schedule ‘a’ part vi representing_______ % __________________ percent above / below the lump sum price of `12, 74, 315.10 inserted by the mes in schedule ‘a’ part vi 7 lump sum price worked out by the contractor for external water supply” as listed in schedule ‘a’ part vii representing_______ % __________________ percent above / below the lump sum price of `3, 22, 790.38 inserted by the mes in schedule ‘a’ part vii 8 lump sum price worked out by the contractor for “sewage disposal” as listed in schedule ‘a’ part viii representing_______ % _________________ percent above / below the lump sum price of `2, 33, 651.38 inserted by the mes in schedule ‘a’ part viii 9 lump sum price worked out by the contractor for “area drainage” as listed in schedule ‘a’ part ix representing_______ % _________________ percent above / below the lump sum price of `14, 10, 891.53 inserted by the mes in schedule ‘a’ part ix 10 lump sum price worked out by the contractor for “special item of work” as listed in schedule ‘a’ part x representing_________ % __________________ percent above / below the lump sum price of `20, 161.00 inserted by the mes in schedule ‘a’ part x 11 this schedule is not prepriced by mes and the prepriced rate indicated in col 5 as ?0.00 indicates this fact only. the tenderer is required to quote their rates in column 6. this schedule constitutes sl. item nos. 23.00 to 110.00. 12 internal electrifications&f, enviroment friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge lit led luminaire comorising of high brightness led 10 watt with polycarbonate housing integrated electronic driver complete with all accessories including internally prewired all as specified and directed.make: havells cat no. hexaft10wled857ssymbopc / philips / crompton greaves / fortune arrt. 13 s&f, led tube light fitting 1 x 20 w, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs20wled865spcss / philips / crompton greaves / fortune arrt. 14 s&f, led tube light fitting 1 x 10 w, 2 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries led as light sources housing complete with all accessories including suitable lamp, internally prewired & including up with twin core twisted flexible copper cable of suitable size all as specified and directed.make: havells cat part no. lumiline + bs10wled865spcss / philips / crompton greaves / fortune arrt. 15 s&f, led building security luminaries 25 watts pressure die cast aluminum housing with ip 66 and replaceable integrated electronic driver led as light sources housing complete with all accessories internally prewired and suitable for pole 40 mm dia all as specified and directed.make: cat part no. endurasundownsl25wled765pasybopcihd of havells / philips / crompton greaves / fortune arrt. 16 s&f, suitable shape street light fitting bracket made out of gi pipe 40 mm dia med grade or of suitable size as per requirement and shape, clamps made out from ms flat of size 40 mm x 6 mm with nuts and bolts ( length of pipe should not less than 1.5 m ) and applying single coat of aluminium paint over a coat of red primer painting complete all as specified and directed by engineer in charge. 17 s&f, ventilating fan metal type 300 mm sweep ac 230 volts 900 rpm with all accessories and louvers including provisioning of hole in wall, making good the disturbed surfaces of wall complete. make: havells venti air ds / crompton greaves / usha. 18 s&f, spn distribution board double door flush type all as per is 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories all as specified and directed by engineer in charge.note: mcbs for out goings shall be measured and paid for separately under relevant items. 19 s&f, connecting and testing mcb single pole and neutral ( mcb spn ) 230 volts of capacity 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 20 s&f, connecting and testing mcb single pole ( mcb sp ) 220 volts of capacity 6 to 32 amps, 10 ka c curve complete all as specified and directed by engineer in charge. 21 supply, fixing & commissioning of cpri approved factory made lt cubical panel board out door type conforming to is / iec 61439 1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415 volts, 3phase, 50hz having aluminium bus bar of capacity 200 amps tpn duly colour coded and for neutral supported with dmc / smc insulators colour coded with heat shrinkable sleeve having short circuit current with minimum 65ka for one second and suitable for internal connection including instaneous over load and earth fault relays complete with digital type volt meter and ammeterincluding suitable range of cts of metering, selector switches for volt meter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels, nut bolts, washers etc, including control accessories: 22 ( a ) incoming mccb 4 pole 415v, 100 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 25 ka 01 no. ( b ) outgoing mccb 4 pole 415v, 63 amps, 50hz with thermal magnetic release and ics = 100% of icu with rupturing capacity 16 ka 02 nos. ( c ) outgoing mcb spn, 32 amps 10 ka c series 230v ac supply 01 no. ( d ) panel mounted type digital multifunctional energy meter a, v, z, kw, pf ct operated, lt 3 phase, 4 wire, including ct ratio 400 / 5 01 no. ( e ) led indicating lamps sets ryb 01 set ( f ) astro time switch 01 no. 23 s&f, two way bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete of size 15mm dia pipe complete all as specified and directed. 24 s&f, 1.2m long chromium plated health foucet including holder fixed to wall complete all as specified and directed by engineer in charge. 25 m&l for cutting of roads / plinth for removal / lalying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed by engineer in charge.note: width 450 mm and depth 600 mm to be excavated for road cutting. 26 construction of septic tank of 5 users capacity, excavation in hard soil, foundation in pcc, brick work in cm 1:4, rcc manholes cover, vent shaft and sludge chambers complete all as specified and directed and shown on td drawings. 27 construction of soakage wells excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of fly ash brick masonary in cm, rcc cover slab in m25 / sfrc cover, interconnecting pipes of rcc / dwc complete filled with brick bats complete all as specified and directed and shown on td drawings. 28 supply, fix, connecting, testing & commissioning of high intensity long range, auto swivel, led search light, beam range 500 meters ( min ) , 1x200w, single, led light, efficiency >130im / w, pf>0.95, cct 5500k 6500k, optional grade pmma pc lens, anti uv oxidation, narrow beam 8 degree, die cast lm6 body with air fins, fully powder coated, working voltage 150to270, 50hz constant current, reflector / lens efficiency >90% average lux level at 5 meter 9000 ( min ) with circle of approximately 600mm, ip 65, confirming to lm79 / lm80 search light should be installed on disc of revolving mechanism with suitable motor gear unit and design such to rotate 360 degree continuously over the night in horizontal plane with speed controller ( 1 to 10 rpm ) & r / f buttons and inbuilt push to tilting option upto 45 degree. a separate wall mounted wired control panel ( consist of mcbs, v meter, fuse, led indicators ) with smooth and safe operation remotely including revolving mechanism fully covered with weather & rust proof fiber box with maintenance window / door with provision of 4 nos foundation holes at bottom for proper installation complete all as specified and directed.make: cat no. mrsl lrfll25 pc20 of make kalin or equivalent make approved by ge....

Smart City Development Corporation Limited - Maharashtra

39594728 tender for sant tukaram natyagruh electrical work 1 supplying and laying rigid steel conduit 16 swg 25 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no: wgma / cc. ( 1 1 4 ) 2 supplying and erecting hms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc ( 1 1 9 ) 3 supplying and layinghms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc ( 1 1 10 ) 4 supplying and erecting hms pvc conduit frls grade25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. ( 1 2 4 ) 5 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 1 ) 6 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw ( 1 3 2 ) 7 supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 7 ) 8 supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. ( 1 6 1 ) 9 supplying and erecting modular type switch 16aduly erected on provided plate and box with wiring connections complete. ( 1 6 2 ) 10 supplying and erecting modular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 10 ) 11 supplying and erecting modular type 3 pin 6 / 16amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 11 ) 12 supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. ( 1 6 14 ) 13 supplying and erecting modular type telephone socket one gangwith safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 15 ) 14 supplying and erecting modular type computer jack rj45 with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 17 ) 15 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. ( 1 6 23 ) 16 supplying and erecting modular type blanking plate two module, duly erected on provided plate & box. ( 1 6 25 ) 17 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 35 ) 18 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 36 ) 19 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 37 ) 20 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 38 ) 21 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 39 ) 22 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 40 ) 23 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background ( 1 6 41 ) 24 point wiring for light / bell / exhaust fan in 20 mm frls grade hms pvcconduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw. ( 1 7 12 ) 25 point wiring for ceilingfan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw ( 1 7 13 ) 26 point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw ( 1 7 14 ) 27 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modulartype switch, earthing and required accessories as per specification no: wgpw / hw ( 1 7 15 ) 28 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / hw 29 wiring for plug on board withswitch socket surface / concealed type, copper wiring and earthing and with modular accessories as per specification no: wg pw / cw ( 1 7 26 ) 30 supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 1 ) 31 supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 7 ) 32 supplying and erecting 15m vga cord low voltage gradeto be laid in provided conduits and terminating with male / female vga connectors complete. ( 1 8 20 ) 33 supplying, erecting and commissioning ofmdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw ( 1 9 1 ) 34 supplying and installingexpansion cabinet for extension of digital hybrid epabx to expand system by 32 ports with programming and configuration of extensions and direct lines with required accessories complete. ( 1 9 33 ) 35 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc ( 1 10 1 ) 36 supplying, fixing, and configuring8 ports managed gigabit, layer 2 switch, 10 / 100 / 1000 base t, poe smart switch plus 2 sfp erected in provided rack complete. ( 1 11 2 ) 37 supplying, installing & testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. ( 1 12 1 ) 38 supplying and fixing42 u floormount server rack ( dimension dxwxh – 800x1000x2070 mm ) as per specification no. wg nas / rak ( 1 12 29 ) 39 supplying and erecting led square / circular max. 18 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 5 ) 40 supplying and erecting led square / circular max. 25 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 6 ) 41 supplying and erecting ledpanel light ( 600mm x 600mm ) max. 35 whaving crca powder coated housing, polystyrene diffuser havingsystem lumens output of min 4200 lumens, min. efficacy of 120 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 8 ) 42 supplying and erecting anodized aluminium corridor / passage light led fitting ( 4 feet ) max. 22wwith high transitivity diffuser withsystem lumens output ofmin.2200 lumens , min. efficacy of 100 lumen / w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%, thd<10%, p.f. >0.95, operating range of200 270v, surge protection of 2 kv, life class of 50, 000 hrs. at l70b50, including driver, with end caps on provided pvc block / wooden board with 3 years warranty. ( 2 1 18 ) 43 supplying and erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8 10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen / watt, cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. ( 2 1 22 ) 44 supplying and erecting uv fly killer / bug catcher light fittinghaving 2 x 20w uv tube lights to cover min. area of 500 sq.ftwith powdered coated m.s. / steel body suitable to work on 230v, ac supply having top mounting arrangement with ss chain complete and 3 core 1 mtr. flexible wire with 1 year warranty. ( 2 1 23 ) 45 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block / sunmica block of suitable size. ( 2 3 13 ) 46 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. ( 2 10 15 ) 47 supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of28w having service ratio ( cmm / w ) of min. 8 , pf>0.9, thd<10% with ir remote control / compatible speed regulator, temperature rise of max. 40 deg. c, having external mounted control pcb completely erected in position as per specification no. fg fn / cf ( 2 10 22 ) 48 supplying and fixinganchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. ( 2 11 2 ) 49 supplying and erecting fan clamp of 30 x 5 mm. m.s. flat of required length and 10 mm.m.s. bolt and nuts erected with necessary hook of 10 mm. m.s. round bar and painted. ( 2 11 3 ) 50 supplying and erecting ‘b’ class g.i .pipe / m.s. pipe down rod duly painted for fan complete erected with pvc three core flexible cable 1 sq. mm copper pvc wire. ( 2 11 6 ) 51 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. ( 2 11 11 ) 52 supplying and erecting 20 swg g.i sheet metal cawl rectangular / round shaped with 25 x 25x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no fg fas / msc ( 2 11 17 ) 53 supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh / 24hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections ( i.e. thermostat & thermalfunctioncut out, valve ) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh / stwh ( 3 1 2 ) 54 supplying, erecting, testing and commissioning ofself contained water cooler 230 / 250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap wcr / wc ( 3 3 10 ) 55 supplying, installing, testing and commissioning of10kva capacity onlinepure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protectionsas per specification no. ap ups ( 3 7 6 ) 56 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 57 supplying and erecting on load four pole automatic transfer switch, 415v, 400a, 50 hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ats controller with provision of time delay protection of ov, uv, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to is / iec 60947 3 part 1 / 6 . ( 5 1 14 ) 58 supplying, erectingandmarking spmcb 6a to 32a, c serieswith rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 2 ) 59 supplying, erectingandmarking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) 60 supplying, erectingandmarking spmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 5 ) 61 supplying, erectingandmarking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 7 ) 62 supplying, erectingandmarking dpmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 8 ) 63 supplying, erectingandmarking tpmcb 6a to 32a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 10 ) 64 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 65 supplying and erecting triplepole and neutral distribution board ( tpndb ) , sp / tp mcbs total 4 ways / 12 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 4 ) 66 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 8 ways / 24 poles, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 5 ) 67 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 12 ways / 36 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / giframe ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 6 ) 68 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 6 ways ( 6 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 8 ) 69 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 9 ) 70 providing and erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and fixed magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 1 ) 71 providing and erecting 3 pole mccb 415v, 250a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 3 ) 72 providing and erecting 3 pole mccb 415v, 400a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustablethermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 4 ) 73 providing and erecting 3 pole mccb 415v, 630a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 5 ) 74 providing and erecting 3 pole mccb, 415v, 800a, rated short circuit breaking capacity 50 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 6 ) 75 supplying, fixing, and commissioning 4 polercbo 6 / 10 / 16 / 20 / 25a, with overcurrent, rated short circuit breaking capacity ( 10 ka ) and earth leakage protection, with 30 / 100 / 300 ma sensitivity and short circuit and earth leakage trip indications per specification no sw rccb / rcbo ( 5 6 12 ) 76 supplying, installing, testing and commissioning ofair circuit breaker manual fixed type, non drawout type, 650v, 1000a rated at 50º c without deration, 12kv impulse, 4 pole ( 100% neutral protection ) , 50 ka ( ics=icu=icw for 1s ) , with standard accessories with ready to close, individual fault trip, alarm and tripindication, mechanical and electrical anti pumping, soft / hard rating plug ( including hard rating plug ct ) with micro processer based lcd display release with lsig and temperature rise protection & with 4 c / o contacts for on off trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. sw swr / acb ( 5 8 3 ) 77 supplying and erecting metal work in crca sheet including iron work for supportswith fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. ( 6 1 1 ) 78 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 79 supplying and erecting 250 kvar, 3 phase, 50 hz., power contactors derated for microprocessor apfc controller with mpp / app type capacitor with 525 v and having minimum overcurrent capacity of 1.8 in, peak inrush current capacity 300 inand minimum life 150000 hours with , consisting of suitable steps of mpp / app type capacitor unitswith detuned aluminium filter 7% reactors with circuit breaker as main incomer and mccb for each branch protection, as per specification no cp ed / apfc ( 6 7 17 ) 80 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 81 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 82 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 83 supplying, erecting & terminating fr xlpe insulated, galvanised steel formedwire armoured ( strip ) cable 1100 v, 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 84 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 85 supplying and erecting g.i. pipe ‘a’ class75 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 4 ) 86 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 200 mm width & 20 mm height complete with necessary hardware. ( 7 11 12 ) 87 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 500 mm width & 20 mm height complete with necessary hardware. ( 7 11 15 ) 88 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 89 supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and / or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no ea ep. ( 9 2 1 ) 90 supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. ( 9 3 1 ) 91 providing and back filling ground enhancing compound 25 kg bag complete. ( 9 3 2 ) 92 supplying, installation and testing of maintenance free earthing comprising ofelectrode of 17.2 mm diameter low carbon steel with 250 micron molecularcopper bonded earthing rod of length 3m along with 25 kg carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity complete, and recording the resultsspecification no. ea mobi ( 9.1.5 ) 93 supplying, erecting, testing and commissioning3 10 watt smart wired led ceiling lamp downlighter wiz connected ( shades of white / warm white + dimmable + pre set modes ) ( non csr ) 94 supplying, erecting, testing and commissioning of wall / floor mounted three phase 415 v electronic dimmer 12x4 kw having rectangular shape semi automatic / dmx type, with ryb indicator, having 24 input jackwith crca housing min 22 gauge with all internal mcb, wiring, controlling accessories complete ( non csr ) 95 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) 96 supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 6600 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg odf / fls2. ( 2 4 5 ) 97 supplying and erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation . ( 5 2 5 ) 98 supplying, erecting & marking spmcb 0.5a to 5a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 1 ) 99 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 100 supplying & erecting triple pole and neutral distribution board ( tpndb ) , 3 pole / 4 pole mccb as incomer & outgoing sp mcb ( 12 poles ) or tp mcb of 4 ways ( 12 poles ) , with door, 1.2mm thickness, surface / flush mounted, on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb1 ( 5 4 15 ) 101 supplying and erecting gi sheet 1.6mm ( 16 swg ) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in marathi, hindi and english erected at position for hv / ehv ( 11000 volts ) installation with compliance to is 2551 1982 ( 6 1 16 ) 102 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 103 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 27 ) 104 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 30 ) 105 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 106 providing and erecting 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl ( 8 2 12 ) 107 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl / pbkt ( 8 2 21 ) 108 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep ( 9 1 1 ) 109 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 110 supplying and erecting gi strip of high purity required size used for earthing on wall and / or any other purpose with necessary gi clampsfixed on wall painted with bituminous paint with joints required. as per specification no ea ep. ( 9 2 3 ) 111 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 112 makingm 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . ( 16 3 9 ) 113 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 114 supplying, fixing, and commissioning mcb type change over switch 4 pole, 40a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos ( 5 3 25 ) 115 supplying and erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb / tp mcb / fp mcb / rccb / rcbo complete erected on angle iron / gi frame. ( 5 4 13 ) 116 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( 7 1 27 ) 117 supplying and erecting g.i. pipe‘a’ class 40 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 2 ) 118 supplying and laying ( including excavation ) of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. ( 7 6 9 ) 119 providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. covercomplete with all materials, testing & recording the results asper specification no. ea ep ( 9 1 3 ) 120 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 121 supplying and erecting minimum three & above star rated submersible pump set of 2.25 kw / 3 hp with 415 v, 50 c / s ac supply suitable for 100 mm dia. borewell suitable for 60 to 170 lpm discharge at 97 to 30 m head & discharge & delivery pipe of size 40 mm diameter with a necessary h type clamps as per specification no. wp smp 122 supplying and erecting minimum three & above star rated submersible pump set suitable for erection on open well of 5.625 kw / 7.5 hp with 415 v 50 c / s. a.c. supply, having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of suction 75 mm / delivery 65 mm diameter erected with necessary h type clamps as per specification no. wp osp ( 12 3 3 ) 123 supplying and erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 8 ) 124 supplying and erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 9 ) 125 supplying and erecting water level controller 230 / 415 v, a.c. , four way under ground & over head tank operation only. ( 12 4 15 ) 126 supplying & erecting pvc coated 5 mm dia. brass sensor / electrode duly wired with nuts & bolts complete ( set of 3 nos ) . ( 12 4 15 ) 127 supplying and erecting automatic control panel for 3 phase , 415 volt, a.c, submersible / centrifugal pump set up to 7.5 hp consisting of dol starter having relay range 9 14 amp, s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc . ( 12 4 17 ) 128 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. ( 16 1 5 ) 129 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 130 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw plb / gp. ( 16 5 6 ) 131 supplying and erecting isi mark gi pipe 75 / 80 mm dia. ‘b’ class at positionwith accessories complete. specification no. cw plb / gp. ( 16 5 8 ) 132 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet / submersible pump with required material complete. ( 16 5 18 ) 133 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. ( 16 6 15 ) 134 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. ( 16 6 21 ) 135 supplying and erectinghms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 1 1 9 136 supplying and laying hms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 1 1 10 137 supplying and erecting 25 mm dia. corrugated flexiblepolypropylene conduit 1 2 2 138 supplying and erecting 10m hdmi cord low voltage grademinimum 4k compliant to be laid in provided conduits with male / female 19 pin hdmi connectors complete.. 1 8 23 139 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc 1 10 1 140 supplying, fixing, and configuring 24 ports, poe switch in provided rack as perspecification no. wg nwc / ens ( 1 11 3 ) 141 supplying, installing and testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. 1 12 1 142 supplying and fixing 9u wall mount rack ( dimension dxwxh – 500x600x500 mm ) as per specification no. wg nas / rak1 12 18 143 supplying and fixing 24 ports light guide unloaded interconnect unit, wall mounted type, with adapter panel for termination of optical fibre cables onwall in provided u rack complete as per specification no. wg nas / liu 1 12 8 144 supplying, installing, testing and commissioning of2kva capacity online pure sine wave, with backup time of 03 hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups ( 3 7 2 ) 145 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 146 supplying, erecting, testing & commissioning 5 mp full ip dome camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 2.8mm@f2.0dori distance 42 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo max. resolution 2592 x 1944video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( include – 12 month fully compressive warranty ) ( rates are as per sanct.lt.no.431 dt.22.03..2022 ) ( non csr ) 147 supplying, erecting, testing & commissioning 5 mp full ip bullet camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 4.0mm@f2.0dori distance 60 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( non csr ) 148 supplying, erecting, testing & commissioningcamera nvr 32 channel system specifications :32ch with 4k real time live preview max 32q mbps incoming bandwidth with h.265 compression, decoding support upto 4 x 4k@30, 8 x 4mp@20 on vif version 2.4 conformance vca search and smart search for playback support 8 sata hdd up to 64tb with raid configuration, 2 usb 2.0, 1 usb. ( non csr ) 149 supplying and installation testing & commissioning of surveillance internal hdd ( hard disk drive ) internal hdd supply , installation testing and commissioning for surveillance hddrecording capacity 8tb. ( non csr ) 150 supplying, erecting, commissioning & testing screen ( 108 cm ) / 40 inchpecifications general o screen size : 108 cm ( 43 ) • screen type : led • hd technology & resolution : full hd tv, 1920 x 1080 • hdmi : 3, usb : 1 • launch year : 2018 onnectivity features : hdmi, 2 side : usb o 1 side video features • contrast ratio : mega contrast ( static ) • picture engine : hyper real • view angle : 178 degree • panel type : a+, digital noise filter : yes • led display type : direct • aspect ratio16:09 • refresh rateo 60 hz • other video features o pmi 300: clarity, color, contrast, active noise reduction, dynamic color enhancer o picture mode: 8 modes ( vivid, standard, aps, cinema, cricket, game, expert1, expert2 ) o picture: jpeg, digital noise reduction, movies support in usb mode, mpeg h.264 decoder o response time: 6.5 ms, still image, wide color enhancer ( plus ) , film mode, cricket mode audio features • number of speakers : 2 • speaker type: down firing with bass reflex • sound technology : dolby digital plus • speaker output rms : 20 w warranty • warranty summary : 1 year comprehensive and 1 year additional on panel. ( non csr ) ...

Directorate Of Municipal Administration - Maharashtra

39593035 supplying and erecting electrical accessories, switch gear, cables etc for year 2023 24 1 pvc copper wire 1 sqmm ( 90m ) 2 pvc copper wire 1.5 sqmm ( 90m ) 3 pvc copper wire 2.5 sqmm ( 90m ) 4 twin core pvc to pvc aluminium service wire 6 sqmm ( 90 ) 5 insulation tape ¾”, 10 mtr 6 icdp main 32 a. 230 v 7 dp switch 32 a, 230 v 8 pianno switch 5 amp 9 socket 5 amp 10 bell push 5amp 11 fan regulator socket type 12 pendent holder 13 batten holder 14 modular switch 5 amp 15 modular socket 5amp 16 modular combined switch socket 16 amp 17 modular switch 15 amp 18 modular socket 15 amp 19 3 pin top 6amp 20 3 pin top 15 amp 21 ding dong bell 22 electronics cordless bell 23 flexible wire 40 x 36 24 porceleian cutout 100 amp 25 screw driver 9 “ 26 insulated piller 8” 27 4 x 25 sqmm pvc armoured cable 28 line tea ster 29 4 pole contractor 45 amp 30 timer 31 mcb 6a to 32 amp 32 supplying submersible pump 2 hp 33 pvc switch box 4 module 34 pvc switch box 8 module 35 casing capping patti 36 led tube light 20 watt 37 led flood light 200 watt 38 led street light 60 watt 39 led fitting driver 10 kva protection 40 exaust fan15 “ heavy duty 41 exaust fan 8 “ 42 ceiling fan56” 43 ceiling fan48” 44 capacitor 2.25 mfd 45 pedestalfan air circulator 450 mm sweep heavy duty 46 wire less telephone instrument gsm based. 47 wall mounted fan 450 mm sweep 48 4 core 120 sqmm armoured cable 49 led bulb 7 watts 50 led bulb 15 watts 51 led panel light15 watts 52 telephone instrument 53 4 polemcb 63 amp 54 aluminium ladder ( ghoda ) 10 feet 55 erecting pvc insulated pvc round sheathed 2.5sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 56 led panel light 2ft x 2ft 57 supplying and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 rpm without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230 / 250 volts single phase, 50 cycles a.c. supply, core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. 58 point wiring in pvc trunking ( casing capping ) with 1.5sq.mm ( 2+1e ) frlsh grade copper wire, flush type switch, earthing and required accessories 59 point wiring for independent plug in pvc trunking ( casingcapping ) with 1.5 sq.mm ( 2+1e ) fr grade copper wire with flush type switch and required accessories 60 wiring for plug on board with switch socket, copper wiringand earthing 61 supplying and erecting pvc surface modular double mounting plate 4 modules complete duly erected. 62 supplying and erecting pvc surface modular doublemounting plate 8 modules complete duly erected. 63 supplying and erecting pvc surface modular doublemounting plate 12 modules complete duly erected. 64 supplying and erecting pvc surface modular double mounting plate 16 / 18 module complete duly erected. 65 supplying and erecting isi mark modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 66 supplying and erecting isi mark modular type 3 pin 6a multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. 67 supplying & erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places 68 supplying & erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. 69 supplying & erecting mains with 2x6 sq.mm frlsh copperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. 70 supplying & erecting mains with 2x10 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places 71 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 72 supplying and erecting pvc insulated pvc round sheathed 2.5sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv 73 supplying and erecting mains with isi mark wp 2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected 74 supplying and erecting isi mark modular type switch 6a / 10aduly erected on provided plate and box with wiring connections complete. 75 supplying and erecting isi mark modular type switch 16a duly erected on provided plate and box with wiring connections complete. 76 supplying 6 amp. 3 pin plug top bakelite type of 230 v. a.c. supply. 77 supplying 16 amp. 3 pin plug top bakelite type of 230 v. a.c. supply. 78 supplying, erecting & terminating xlpe armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 79 supplying, erecting & terminating xlpe armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 80 supplying, erecting & terminating xlpe armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm ( 10 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe. 81 supplying, erecting & terminating xlpe armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq.mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 82 supplying, erecting & terminating xlpe armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. ( 8 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 83 supplying, erecting & terminating xple armoured cable 4 core 16sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 84 supplying, erecting & terminating xlpe armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. ( 12 swg ) g.i. earth wire complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe 85 making trench of suitable width and depth in soft soil for laying provided lt cable up to and including 16 sq.mm complete as per specification no. cw exn ctr 86 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results 87 supplying & erecting led 20w tube light fitting ( 4 feet ) with aluminium housing, heat sink, integrated hf electronic driver complete. 88 supplying & erecting 5w 7w, 230v integral type led lamp suitable for b 22 / e 27 base. 89 supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e 27 base. 90 supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. 91 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wiremesh, duly erected in an approved manner. 92 supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position 93 supplying and erecting regular / standard model ceiling fan of 600mm. sweep complete erected in position 94 supplying and erecting regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position as per specification no. fg fn / cf 95 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 96 providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm without speed regulator, overheatprotection unit, totally enclosed, flame proof motor suitable for230 / 250 volts single phase, 50 cycles a.c. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘e’ class 97 supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wiremesh, duly erected in an approved manner. 98 supplying and erecting electronic type step regulator for ceiling fan 600 / 900 / 1200 / 1400 mm. sweep, complete erected on provided switch board. 99 supplying and erecting ultra violet storage type water purifier ( ro+uv+uf ) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water 7 to 8 litre / min with activated carbon filter and softener operating on 230 v single phase a.c. supply. 100 supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 2 litre / min. with activated carbon filter and softener operating on 230 v single phase ac supply. 101 supplying and erecting isi mark midget type 3.0 ltr storage type water heater of abs plastic body 3 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 102 supplying and erecting isi mark midget type 10.0 ltr storage type water heater of abs plastic body 5 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 103 supplying and erecting isi mark midget type 1.0 ltr instand type water heater of abs plastic body 1 kw, heating element 230 / 250 volts 50 cycle ac supply with inlet and outlet, thermostatic control and thermal cutoffwith 3 core pvc flexible wire leads complete duly tested and marking sr. no. and date of erection. 104 supplying, installing, testing and commissioning split type variable speed inverter technology room air conditioning unit 1.5 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hiwall / floor mounting type complete with refrigerant r410 a / r32 and copper condenser at position 105 supplying, installing, testing and commissioning split type variable speed inverter technology room airconditioning unit 1 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hi wall mounting type complete with refrigerant r410a / r32 and copper ondenser at position. 106 supplying, installing, testing and commissioning split type variable speed inverter technology room air conditioning unit 2 tr capacity having iseer minimum 3.50 to maximum 3.99 suitable to operate on 250v, 50 cycles, a.c. supply having 1 no. of air handling unit hi wall / floor mounting type complete with refrigerants r410 a / r32 and copper condenser at position 107 supplying, erecting & marking spmcb 6a to 32a, c series ( for motor / power ) 108 supplying, erecting & marking dpmcb 40a to 63a, c series ( for motor / power ) in provided distribution board 109 supplying & erecting original 1.25 mm crca sheet metalenclosures with 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with 20a / 30a single pole mcb complete 110 spike guard protector 4 switch 4 socket 111 supplying, fixing and commissioningchange overswitch 4 pole, 100 a 112 supplying, fixing and commissioningchange overswitch 4 pole, 200 a 113 supplying and installing water dispenser having hot / cold cabinet both facility, floor mounted. 114 supplying & erecting condenser 2.25 mfd 115 supplying & erectingbulb holder. 116 supplying and erecting pvc trunking ( pvc casing n capping ) of size 25 mm with accessories on wall / ceiling 117 supplying, installing, testing and commissioning window model mounted type room air conditioner having iseer minimum 3.1 to maximum 3.29 suitable to operate on 230 / 250 v 50 cycles single phase a.c.supply 1.5 tr capacity with refrigerant r410a / r32 and copper 118 supplying and erecting gi sheet 1.25 mm ( 18 swg ) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint 119 supplying and erecting isi mark g.i. pipe pole ‘b’ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation 120 supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation 121 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 122 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 123 supplying and erecting 9m ( clear height ) fixed type high mast ( top 100mm, bottom 200mm ) with hexagonal / round bracket and foundation bolts suitable for max. 4 nos floodlight fixtures on provided foundation 124 providing & erecting 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70mm a / f 125 providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70mm a / f 126 providing & erecting 8 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 135 mm a / f, top 70mm a / f on provided foundation 127 providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70mm a / f on provided foundation 128 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball 129 providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball 130 supplying and erecting outdoor stand mounted feeder pillar for highmast of the same manufacturer with 32a tpn mcb incomer, single dial timer switch, 25a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, andprovision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected with cc foundation complete. 131 providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials 132 supplying and erecting street light wall bracket made from 40 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete 133 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugatedpipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 134 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 40 a, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the maximum load of 6 kw on provided iron frame / cc foundation complete. 135 making cement concrete foundation including excavation ( 45 x 45x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( for 6 m pole ) 136 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 3 to 5m octagonal / conical gi pole ) . 137 making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . 138 making m 20 grade reinforced cement concrete foundation byconsidering the safe soil bearing capacity at site as 10 t / sq.m at 1.5m depth including supply of steel, concrete, excavation and fixingprovided nut bolts with the help of template, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) . 139 making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t / sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 12.5 m raising lowering high mast ) . 140 painting of pipe pole upto 6 m length along with street light / pole brackets / clamps etc by scrapping the existing paint complete. 141 painting of steel tubular / rail / rsj pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping theexisting paint complete. 142 painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. 143 rewinding motor of the 1200 / 1400 mm ceiling fan and overhauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing of fan for original speed and consumption with guarantee for one year 144 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sinkextruded aluminium complete 145 supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heatsink extruded aluminium complete 146 supplying and erecting led street light fitting suitable for above75w 90w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 147 supplying and erecting led street light fitting 100w, includingclass ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 148 supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete 149 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminiumcomplete 150 supplying and erecting led flood light fitting of 200w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminiumcomplete 151 supplying erecting testing self contained water coolerwith stainless steel tank 40 litreshour & storage 80 litres 3 star 152 supplying and erecting 12v / 180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 153 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor ( igbt ) technology complete as per specification no. ap inv...

Directorate Of Municipal Administration - Maharashtra

39549354 supply of electrical material for municipal council nilanga as per requirement 1 led street light fitting 18 w 2 led street light fitting 25w 3 led street light fitting36w 4 led street light fitting60w 5 led street light fitting70w 6 led street light fitting 100w 7 led flood light fitting 100w 8 led flood light fitting 120w 9 led flood light fitting of 150w 10 led flood light fitting of 200w 11 18 w led plate 12 60 w led plate ???? 13 60 w led plate ???? 14 70 w led plate 15 100 w led plate 16 100 w led flood light plate 17 120 w led flood light plate 18 150 w led flood light plate 19 200 w led flood light plate 20 18 w led driver kit 21 60 w led driver kit 22 70 w led driver kit 23 100 w led driver kit 24 120 w led driver kit 25 150 w led driver kit 26 200 w led driver kit 27 led 18 w ceiling fitting square / round shaped 28 led 24 w ceiling fitting square / round shaped 29 led 36 wpanel fitting square / shaped 30 led 18 w ceiling fitting square / round shaped driver kit 31 led 24 w ceiling fitting square / round shaped driver kit 32 led 36 wpanel fitting square / shaped driver kit 33 led 18wtube light set 34 led 20wtube light set 35 led 9w bulb 36 led 12w bulb 37 led 18w bulb 38 100 w led 39 180 w led 40 150 w led 41 250 w led 42 led solar street light of appropriate size suitable forlumen efficacy 90lumen / wattat ground level with mounting height of fitting 5 7 m height from ground with ip 65 ingress protection with 24 / 26w, lux level at ground min 50 lux, with p.f. > 0.95 43 2x2.5 sq.mm f.r copper pvc insulated wire bunch 44 pvc cable 2 core 10 sq mm aluminium conductorbunch 45 pvc cable 2 core 2.5 sq mm aluminium conductorbunch 46 30 / 40 47 service wire 4mm bunch 48 service wire 6mm bunch 52 cut out 32a 53 cut out 63a 54 cut out 100a 55 cut out 200a 56 12 v / 40ah tubular battery 57 12 v / 80ah tubular battery 58 12 v / 150ah tubular battery 59 12 v / 180ah tubular battery 60 12 v / 200ah tubular battery 61 inverter pure sine wave 1400 1600va 62 600v a ups for computer 63 online upspure sinewave of1 kva capacity 64 online upspure sinewave of3 kva capacity 65 stabilizer 0.5kva 66 stabilizer 1kva 67 ceiling fan 68 exhaust fan 71 armored cable 88 two pole power contactor 250v 32a for time switch complete 89 4 pole power contactor 440v 40a for time switch complete 90 programmable digital almanac timer micro controller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230v / 10a 91 short time delay circit with ic 55 ( for linr reactor ) 92 street light wall bracket made from 25 mm.dia ‘b’class g.i. pipe 1.2 m 93 insulation tape box ( 30 tape ) 96 street light bracket 25 mm dia 97 street light bracket 40 mm dia 100 spmcb 6a to 32 a. 101 spmcb 6a to 32 a. 102 tpmcb 40a to 63a 103 m.c.b. 12 way triplepole and neutral distribution board ( tpndb ) 104 tp mcb db vertical 4 waytriplepole and neutral distribution board ( tpndb ) 105 tpmcb db 8 waytriplepoleand neutral distribution board ( tpndb ) 106 mccb 100 a. 3 pole mccb 107 fluroscent tube 40 w 108 fluroscent tube 36 w 109 cfl36 w ??? 110 tube starter 40 w 168 changover panel box set 169 ac servicing 170 generater servicing 171 cement pole complete set 172 11 kvpin insulator with gi pin 173 disc insulator 11kv 174 11kv v cross arm with clamp 175 11kv top fiutting with clamp 176 gi nut bolts per kg 177 ht stay set 178 gi stay wire 7 / 4mm per kg 179 earthing set ht 180 gi wire 8swg / 6swg per kg 181 extension board set...

Rural Development Department - Maharashtra

39447037 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Konkan Railway Corporation Limited - Maharashtra

39343041 bids are invited for digital time switch with two change over din type programmable every 1 min total 14 program per chan (q3) , surface mounting type time switch housed in non metalic case programable operates on external illumi (q3) total quantity : 42...

Rural Development Department - Maharashtra

39216263 supplying electrical materials and repairs maintenance services at. grampanchayat induri, tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 kren rent ( per day basis ) 81 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Public Works Department - Maharashtra

39100070 e rate quotation of non dsr items for preparation of estimate for the work proposed erecting grand shri ram sculpture and installing music fountain and fasad lights and electrification at the ram shrushti udyan, tapovan, panchvati nashik in the juris , supply of 108 feet flag mast. the mast shall befabricated from special steel plates. conforming to 355 grade as per bs en10 025, cut and folded to form a polygonal section welded. the welding is in accordance with bs 5135. at site the section shall be joined together by slipstressed fit method. no side welding or bolted joint shall be done on the mast. the minimum overlap distance shall be 1.5 times the diameter at penetration. the mast shall be provided with fully penetrated flange. which is free from any lamination or incursion. for the environmental protection of the mast. the entire fabricated mast shall be hot dip galvanized, internally and externally as per bs en iso 1461. suitable for wind velocity as per 15875. after galvanization. mast should be pu painted with caching primer and white pu paint. an adequate door opening shall be provided at the base of the mast and the opening is such that it permits clear access to equipment like winches, cables, plug and socket, etc. and also facilitates casy removal of the winch if required flagmast includes system for raising lowering of flag it shall have double drum winch.6 mm dia stainless steel wire. rope and integral power tool for the raising and lowering of flag suitable control panel shall be provided forreversing operation of power tool motor. also arrangement for fixing led aviation system and 3c 2.5 sqmm cu armoured cable the door opening shall be complete with a close fitting. vandal resistant, catherproof door, provided with heavyduty double mtemal lock with special paddle key. supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. make bajaj. valmont, transrail. and with annual maintenance for 5 year , erection of the flag mast with the help of suitable and required equipments, and assembling all operating system assembly of all sections with help required manually, machinery ( crien, jcb ) and installing it on the foundation. all electrical connections and installation of flag to the mast and giving successful trial , itc of low intensity aviation obstruction lamp witha type system. ledwatch z30 a inbuilt photo switch. design conforming to icao annex 14. aviation lamp included 300 nos superbright leds in red color. input working voltage 230v ac ( + / 10 %l light intensity of the lamp> 10 candela @ 360. power consumption should be < 09 watts. number of circuits are six in series / parallel. average burning , life of lamp should be 100000 hrs. plv protection upto 1ky. ip rating should be lp65 as per is 13947 ( part 1 ) 1993. body material of the lamp should be pres ure cast aluminum and dome should be in red color with transparent polycarbonate with endless neoprene gasket. all over finishing of the lamp is golden yellow powder coated with 60 micron thick. connecting lids of lamp with connector upto 01 mtr for 3c x 2.5 sqmm cu armoured ( with ups and battery for support ) , supplying & erecting street light control panel in powder coated crca 14116 swg sheet, outdoor type. single phase. 240 volts consisted of suitable rating contactor, 24 hrs digital / astronomical time switch. spn mcb 63 amp. auto / manual selector switch. on / off push buttons. indicator lamps, control_viring. metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation , supply and installation of the national flag / orange flag of india as per the norms of flag code of india size: 20 feetx 30 feet...

Smart City Development Corporation Limited - Maharashtra

39098185 tender document for sant tukaram natyagruh electrical work 1 supplying and laying rigid steel conduit 16 swg 25 mm dia. with necessary accessories in rcc work / false ceiling / false flooring as per specification no: wgma / cc. ( 1 1 4 ) 2 supplying and erecting hms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc ( 1 1 9 ) 3 supplying and layinghms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc ( 1 1 10 ) 4 supplying and erecting hms pvc conduit frls grade25 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma / con. ( 1 2 4 ) 5 supplying and erecting mains with 2x1.5 sq.mm frlshcopperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 1 ) 6 supplying and erecting mains with 2x2.5 sq.mmfrlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw ( 1 3 2 ) 7 supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw ( 1 3 7 ) 8 supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. ( 1 6 1 ) 9 supplying and erecting modular type switch 16aduly erected on provided plate and box with wiring connections complete. ( 1 6 2 ) 10 supplying and erecting modular type 3 pin 6amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 10 ) 11 supplying and erecting modular type 3 pin 6 / 16amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 11 ) 12 supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. ( 1 6 14 ) 13 supplying and erecting modular type telephone socket one gangwith safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 15 ) 14 supplying and erecting modular type computer jack rj45 with safety shutter, duly erected on provided plate and box with wiring connections complete. ( 1 6 17 ) 15 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. ( 1 6 23 ) 16 supplying and erecting modular type blanking plate two module, duly erected on provided plate & box. ( 1 6 25 ) 17 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 35 ) 18 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 36 ) 19 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 37 ) 20 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 38 ) 21 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 39 ) 22 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. ( 1 6 40 ) 23 supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background ( 1 6 41 ) 24 point wiring for light / bell / exhaust fan in 20 mm frls grade hms pvcconduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw. ( 1 7 12 ) 25 point wiring for ceilingfan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthingand required accessories as per specification no: wg pw / sw ( 1 7 13 ) 26 point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm ( 2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw / sw ( 1 7 14 ) 27 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modulartype switch, earthing and required accessories as per specification no: wgpw / hw ( 1 7 15 ) 28 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw / hw 29 wiring for plug on board withswitch socket surface / concealed type, copper wiring and earthing and with modular accessories as per specification no: wg pw / cw ( 1 7 26 ) 30 supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 1 ) 31 supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s / ws 113c laid in provided pvc casing capping / conduit as perspecification no. wg tw ( 1 8 7 ) 32 supplying and erecting 15m vga cord low voltage gradeto be laid in provided conduits and terminating with male / female vga connectors complete. ( 1 8 20 ) 33 supplying, erecting and commissioning ofmdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw ( 1 9 1 ) 34 supplying and installingexpansion cabinet for extension of digital hybrid epabx to expand system by 32 ports with programming and configuration of extensions and direct lines with required accessories complete. ( 1 9 33 ) 35 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc ( 1 10 1 ) 36 supplying, fixing, and configuring8 ports managed gigabit, layer 2 switch, 10 / 100 / 1000 base t, poe smart switch plus 2 sfp erected in provided rack complete. ( 1 11 2 ) 37 supplying, installing & testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. ( 1 12 1 ) 38 supplying and fixing42 u floormount server rack ( dimension dxwxh – 800x1000x2070 mm ) as per specification no. wg nas / rak ( 1 12 29 ) 39 supplying and erecting led square / circular max. 18 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 5 ) 40 supplying and erecting led square / circular max. 25 w down lighter / panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 6 ) 41 supplying and erecting ledpanel light ( 600mm x 600mm ) max. 35 whaving crca powder coated housing, polystyrene diffuser havingsystem lumens output of min 4200 lumens, min. efficacy of 120 lumen / w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd<10%, p.f. >0.95, operating range of120 270v, surge protection of 2.5 kv, life class of 50, 000 hrs. at l70b50including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. ( 2 1 8 ) 42 supplying and erecting anodized aluminium corridor / passage light led fitting ( 4 feet ) max. 22wwith high transitivity diffuser withsystem lumens output ofmin.2200 lumens , min. efficacy of 100 lumen / w, cri>80, cct upto 6000k, beam angle of 110 deg., ripple<5%, thd<10%, p.f. >0.95, operating range of200 270v, surge protection of 2 kv, life class of 50, 000 hrs. at l70b50, including driver, with end caps on provided pvc block / wooden board with 3 years warranty. ( 2 1 18 ) 43 supplying and erecting inverter led batten 20w tube light fitting with polycarbonate housing, heat sink, integrated hf electronic driver, min. 2600 mah lithium ion battery with charging time of 8 10 hours and backup time of min. 3 hrs. with minimum 25% of initial watts having luminous efficacy of 100 lumen / watt, cri>80, cct of 6500k and thd<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty. ( 2 1 22 ) 44 supplying and erecting uv fly killer / bug catcher light fittinghaving 2 x 20w uv tube lights to cover min. area of 500 sq.ftwith powdered coated m.s. / steel body suitable to work on 230v, ac supply having top mounting arrangement with ss chain complete and 3 core 1 mtr. flexible wire with 1 year warranty. ( 2 1 23 ) 45 supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230v a.c. supply erected on polished double wooden block / sunmica block of suitable size. ( 2 3 13 ) 46 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. ( 2 10 15 ) 47 supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of28w having service ratio ( cmm / w ) of min. 8 , pf>0.9, thd<10% with ir remote control / compatible speed regulator, temperature rise of max. 40 deg. c, having external mounted control pcb completely erected in position as per specification no. fg fn / cf ( 2 10 22 ) 48 supplying and fixinganchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. ( 2 11 2 ) 49 supplying and erecting fan clamp of 30 x 5 mm. m.s. flat of required length and 10 mm.m.s. bolt and nuts erected with necessary hook of 10 mm. m.s. round bar and painted. ( 2 11 3 ) 50 supplying and erecting ‘b’ class g.i .pipe / m.s. pipe down rod duly painted for fan complete erected with pvc three core flexible cable 1 sq. mm copper pvc wire. ( 2 11 6 ) 51 providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. ( 2 11 11 ) 52 supplying and erecting 20 swg g.i sheet metal cawl rectangular / round shaped with 25 x 25x 3 ( mm ) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no fg fas / msc ( 2 11 17 ) 53 supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh / 24hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections ( i.e. thermostat & thermalfunctioncut out, valve ) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh / stwh ( 3 1 2 ) 54 supplying, erecting, testing and commissioning ofself contained water cooler 230 / 250v 50hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. ap wcr / wc ( 3 3 10 ) 55 supplying, installing, testing and commissioning of10kva capacity onlinepure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protectionsas per specification no. ap ups ( 3 7 6 ) 56 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 57 supplying and erecting on load four pole automatic transfer switch, 415v, 400a, 50 hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ats controller with provision of time delay protection of ov, uv, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to is / iec 60947 3 part 1 / 6 . ( 5 1 14 ) 58 supplying, erectingandmarking spmcb 6a to 32a, c serieswith rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 2 ) 59 supplying, erectingandmarking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) 60 supplying, erectingandmarking spmcb 40a to 63a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 5 ) 61 supplying, erectingandmarking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 7 ) 62 supplying, erectingandmarking dpmcb 40a to 63a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 8 ) 63 supplying, erectingandmarking tpmcb 6a to 32a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 10 ) 64 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 65 supplying and erecting triplepole and neutral distribution board ( tpndb ) , sp / tp mcbs total 4 ways / 12 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 4 ) 66 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 8 ways / 24 poles, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 5 ) 67 supplying and erecting triplepoleand neutral distribution board ( tpndb ) , sp / tp mcbs total 12 ways / 36 poles, with door, 1.2mm thickness surface / flushmounted, ip 43 protection on iron / giframe ( vertical busbar type ) as per specification no. sw swr / mcbdb ( 5 4 6 ) 68 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 6 ways ( 6 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 8 ) 69 supplying and erecting single pole and neutral distributionboard ( spndb ) , with 2 ways for incoming and 10 ways ( 10 poles ) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr / mcbdb ( 5 4 9 ) 70 providing and erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and fixed magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact.mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 1 ) 71 providing and erecting 3 pole mccb 415v, 250a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 3 ) 72 providing and erecting 3 pole mccb 415v, 400a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustablethermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 4 ) 73 providing and erecting 3 pole mccb 415v, 630a, rated short circuit breaking capacity 36 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 5 ) 74 providing and erecting 3 pole mccb, 415v, 800a, rated short circuit breaking capacity 50 ka ( ics=100% of icu ) , adjustable thermal ( overload ) setting and adjustable magnetic setting with provided leads, provision for installation of shunt / uv / trip alarm contact and mccb should have phase barriers both sides, with insulation withstand capacity 800v, no line load bias in provided enclosure / panel as per specification no. sw swr / mccb ( 5 5 6 ) 75 supplying, fixing, and commissioning 4 polercbo 6 / 10 / 16 / 20 / 25a, with overcurrent, rated short circuit breaking capacity ( 10 ka ) and earth leakage protection, with 30 / 100 / 300 ma sensitivity and short circuit and earth leakage trip indications per specification no sw rccb / rcbo ( 5 6 12 ) 76 supplying, installing, testing and commissioning ofair circuit breaker manual fixed type, non drawout type, 650v, 1000a rated at 50º c without deration, 12kv impulse, 4 pole ( 100% neutral protection ) , 50 ka ( ics=icu=icw for 1s ) , with standard accessories with ready to close, individual fault trip, alarm and tripindication, mechanical and electrical anti pumping, soft / hard rating plug ( including hard rating plug ct ) with micro processer based lcd display release with lsig and temperature rise protection & with 4 c / o contacts for on off trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. sw swr / acb ( 5 8 3 ) 77 supplying and erecting metal work in crca sheet including iron work for supportswith fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. ( 6 1 1 ) 78 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 79 supplying and erecting 250 kvar, 3 phase, 50 hz., power contactors derated for microprocessor apfc controller with mpp / app type capacitor with 525 v and having minimum overcurrent capacity of 1.8 in, peak inrush current capacity 300 inand minimum life 150000 hours with , consisting of suitable steps of mpp / app type capacitor unitswith detuned aluminium filter 7% reactors with circuit breaker as main incomer and mccb for each branch protection, as per specification no cp ed / apfc ( 6 7 17 ) 80 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 81 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 82 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 83 supplying, erecting & terminating fr xlpe insulated, galvanised steel formedwire armoured ( strip ) cable 1100 v, 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 84 supplying, erecting & terminating fr xlpe insulated, galvanised steelformed wire armoured ( strip ) cable 1100 v, 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid inprovided trench / pipe as per specification no. cb lt / al 85 supplying and erecting g.i. pipe ‘a’ class75 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 4 ) 86 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 200 mm width & 20 mm height complete with necessary hardware. ( 7 11 12 ) 87 providing and erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 swg ( 1.2 mm thick ) gi sheet of 500 mm width & 20 mm height complete with necessary hardware. ( 7 11 15 ) 88 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 89 supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and / or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no ea ep. ( 9 2 1 ) 90 supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. ( 9 3 1 ) 91 providing and back filling ground enhancing compound 25 kg bag complete. ( 9 3 2 ) 92 supplying, installation and testing of maintenance free earthing comprising ofelectrode of 17.2 mm diameter low carbon steel with 250 micron molecularcopper bonded earthing rod of length 3m along with 25 kg carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity complete, and recording the resultsspecification no. ea mobi ( 9.1.5 ) 93 supplying, erecting, testing and commissioning3 10 watt smart wired led ceiling lamp downlighter wiz connected ( shades of white / warm white + dimmable + pre set modes ) ( non csr ) 94 supplying, erecting, testing and commissioning of wall / floor mounted three phase 415 v electronic dimmer 12x4 kw having rectangular shape semi automatic / dmx type, with ryb indicator, having 24 input jackwith crca housing min 22 gauge with all internal mcb, wiring, controlling accessories complete ( non csr ) 95 supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) 96 supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 6600 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including driver complete with 3 years warranty as per specification nofg odf / fls2. ( 2 4 5 ) 97 supplying and erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / cc foundation . ( 5 2 5 ) 98 supplying, erecting & marking spmcb 0.5a to 5a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 1 ) 99 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 100 supplying & erecting triple pole and neutral distribution board ( tpndb ) , 3 pole / 4 pole mccb as incomer & outgoing sp mcb ( 12 poles ) or tp mcb of 4 ways ( 12 poles ) , with door, 1.2mm thickness, surface / flush mounted, on iron / gi frame ( vertical busbar type ) as per specification no. sw swr / mcbdb1 ( 5 4 15 ) 101 supplying and erecting gi sheet 1.6mm ( 16 swg ) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in marathi, hindi and english erected at position for hv / ehv ( 11000 volts ) installation with compliance to is 2551 1982 ( 6 1 16 ) 102 supplying and erecting iron work, sheet metal work consisting of crcasheets, varioussectionsofiron, plates, chequeredplates, rods, bars, mspipes, etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. ( 6 1 19 ) 103 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 27 ) 104 supplying, erecting & terminating xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( note for use of xlpe insulation instead of fr xlpe insulated armoured cable reduce rates by 5 % ) ( 7 1 30 ) 105 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 106 providing and erecting 6 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl ( 8 2 12 ) 107 providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl / pbkt ( 8 2 21 ) 108 providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep ( 9 1 1 ) 109 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 110 supplying and erecting gi strip of high purity required size used for earthing on wall and / or any other purpose with necessary gi clampsfixed on wall painted with bituminous paint with joints required. as per specification no ea ep. ( 9 2 3 ) 111 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 112 makingm 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 t / sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 6m to 8m high octagonal / conical gi pole ) . ( 16 3 9 ) 113 supplying, erectingandmarking tpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 11 ) 114 supplying, fixing, and commissioning mcb type change over switch 4 pole, 40a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos ( 5 3 25 ) 115 supplying and erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb / tp mcb / fp mcb / rccb / rcbo complete erected on angle iron / gi frame. ( 5 4 13 ) 116 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipeas per specification no. cb lt / al ( 7 1 27 ) 117 supplying and erecting g.i. pipe‘a’ class 40 mmdia.erectedfor enclosingxlpearmouredcable on wall / poleas per specification no. cb ce ( 7 6 2 ) 118 supplying and laying ( including excavation ) of suitable width & depth up to 90 cm ) 50 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. ( 7 6 9 ) 119 providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. covercomplete with all materials, testing & recording the results asper specification no. ea ep ( 9 1 3 ) 120 providing pipetype earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rodcomplete with all materials testing and recording the results as per specification no. ea ep ( 9 1 4 ) 121 supplying and erecting minimum three & above star rated submersible pump set of 2.25 kw / 3 hp with 415 v, 50 c / s ac supply suitable for 100 mm dia. borewell suitable for 60 to 170 lpm discharge at 97 to 30 m head & discharge & delivery pipe of size 40 mm diameter with a necessary h type clamps as per specification no. wp smp 122 supplying and erecting minimum three & above star rated submersible pump set suitable for erection on open well of 5.625 kw / 7.5 hp with 415 v 50 c / s. a.c. supply, having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of suction 75 mm / delivery 65 mm diameter erected with necessary h type clamps as per specification no. wp osp ( 12 3 3 ) 123 supplying and erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 8 ) 124 supplying and erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( 12 4 9 ) 125 supplying and erecting water level controller 230 / 415 v, a.c. , four way under ground & over head tank operation only. ( 12 4 15 ) 126 supplying & erecting pvc coated 5 mm dia. brass sensor / electrode duly wired with nuts & bolts complete ( set of 3 nos ) . ( 12 4 15 ) 127 supplying and erecting automatic control panel for 3 phase , 415 volt, a.c, submersible / centrifugal pump set up to 7.5 hp consisting of dol starter having relay range 9 14 amp, s.p.p., combined ammeter / voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc . ( 12 4 17 ) 128 excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay / earth plate / for laying cable / pipe & clearing the site by removing debris & making the site as required complete. ( 16 1 5 ) 129 making cement concretefoundationin 1:3:6 cement concrete, ( 20 to 25 ) mm. stone metal duly plastered with necessary curing forcomplete. ( pole muffing or any other purpose ) . ( 16 3 7 ) 130 supplying and erecting isi mark gi pipe 50 mm dia.‘b’ class at position with accessories complete as per specification no. cw plb / gp. ( 16 5 6 ) 131 supplying and erecting isi mark gi pipe 75 / 80 mm dia. ‘b’ class at positionwith accessories complete. specification no. cw plb / gp. ( 16 5 8 ) 132 supplying and erecting high density polythene pipe isi mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet / submersible pump with required material complete. ( 16 5 18 ) 133 supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. ( 16 6 15 ) 134 supplying and erecting non return valve 50 mm dia in position made of gun metal complete. ( 16 6 21 ) 135 supplying and erectinghms pvc conduit frls grade 25 mm dia. with necessary accessories in wall / floor with chiselling appropriately as per specification no: wg ma / cc. 1 1 9 136 supplying and laying hms pvc conduit frls grade 25 mm dia with necessary accessories in rcc work / false ceiling / false flooring as per specification no. wg ma / cc. 1 1 10 137 supplying and erecting 25 mm dia. corrugated flexiblepolypropylene conduit 1 2 2 138 supplying and erecting 10m hdmi cord low voltage grademinimum 4k compliant to be laid in provided conduits with male / female 19 pin hdmi connectors complete.. 1 8 23 139 supplying and installingcat 6 cable suitable for networking as per specification no. wg coc / nc 1 10 1 140 supplying, fixing, and configuring 24 ports, poe switch in provided rack as perspecification no. wg nwc / ens ( 1 11 3 ) 141 supplying, installing and testing utp connector ( rj 45 ) as per specification no. wg nas / utpc. 1 12 1 142 supplying and fixing 9u wall mount rack ( dimension dxwxh – 500x600x500 mm ) as per specification no. wg nas / rak1 12 18 143 supplying and fixing 24 ports light guide unloaded interconnect unit, wall mounted type, with adapter panel for termination of optical fibre cables onwall in provided u rack complete as per specification no. wg nas / liu 1 12 8 144 supplying, installing, testing and commissioning of2kva capacity online pure sine wave, with backup time of 03 hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups ( 3 7 2 ) 145 supplying and erecting 12v / 100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. ( 3 8 12 ) 146 supplying, erecting, testing & commissioning 5 mp full ip dome camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 2.8mm@f2.0dori distance 42 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo max. resolution 2592 x 1944video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( include – 12 month fully compressive warranty ) ( rates are as per sanct.lt.no.431 dt.22.03..2022 ) ( non csr ) 147 supplying, erecting, testing & commissioning 5 mp full ip bullet camera complete. camera sensor 1 / 2.7, 5.0 megapixel, progressive scan, cmoslens 4.0mm@f2.0dori distance 60 meter detectshutter auto / manual, 1 ~ 1 / 100000s colour: 0.01lux ( f2.0, agc on ) minimum illumination 0lux with ir ondigital noise reduction 2d / 3d dnrday / night ir cut filter with auto switch ( icr ) s / n >52dbir range up to 30m ( 98ft ) ir rangewavelength 850nmir on / off control auto / manualdefog digital defogwdr dwdrvideo video compression ultra 265, h.265, h.264, mjpegh.264 code profile baseline profile, main profileframe rate main stream: 5mp ( 2592*1944 ) , min 25fps; sub stream: 720p ( 1280×720 ) , min 20fpsvideo bit rate 128 kbps~16 mbpsosd up to 4 osdsprivacy mask up to 4 areasroi up to 2 areasmotion detection up to 4 areasimage white balance auto / outdoor / fine tune / sodium lamp / locked / auto2digital noise reduction 2d / 3d dnrsmart ir supportflip normal / vertical / horizontal / 180°dewarping nahlc supportedblc supportednetwork protocols ipv4, igmp, icmp, arp, tcp, udp, dhcp, rtp, rtsp, rtcp, dns, ddns, ntp, ftp, upnp, http, https, smtp, ssl, qosinterface 10 / 100m base tx ethernetcompatible integration onvif ( profile s, profile t ) , apicertifications certifications ce: en 60950 1 / ul: ul60950 1 / fcc: fcc part 15 ( non csr ) 148 supplying, erecting, testing & commissioningcamera nvr 32 channel system specifications :32ch with 4k real time live preview max 32q mbps incoming bandwidth with h.265 compression, decoding support upto 4 x 4k@30, 8 x 4mp@20 on vif version 2.4 conformance vca search and smart search for playback support 8 sata hdd up to 64tb with raid configuration, 2 usb 2.0, 1 usb. ( non csr ) 149 supplying and installation testing & commissioning of surveillance internal hdd ( hard disk drive ) internal hdd supply , installation testing and commissioning for surveillance hddrecording capacity 8tb. ( non csr ) 150 supplying, erecting, commissioning & testing screen ( 108 cm ) / 40 inchpecifications general o screen size : 108 cm ( 43 ) • screen type : led • hd technology & resolution : full hd tv, 1920 x 1080 • hdmi : 3, usb : 1 • launch year : 2018 onnectivity features : hdmi, 2 side : usb o 1 side video features • contrast ratio : mega contrast ( static ) • picture engine : hyper real • view angle : 178 degree • panel type : a+, digital noise filter : yes • led display type : direct • aspect ratio16:09 • refresh rateo 60 hz • other video features o pmi 300: clarity, color, contrast, active noise reduction, dynamic color enhancer o picture mode: 8 modes ( vivid, standard, aps, cinema, cricket, game, expert1, expert2 ) o picture: jpeg, digital noise reduction, movies support in usb mode, mpeg h.264 decoder o response time: 6.5 ms, still image, wide color enhancer ( plus ) , film mode, cricket mode audio features • number of speakers : 2 • speaker type: down firing with bass reflex • sound technology : dolby digital plus • speaker output rms : 20 w warranty • warranty summary : 1 year comprehensive and 1 year additional on panel. ( non csr ) ...

Airports Authority Of India - Maharashtra

39073811 tender for construction of new dvorat aurangabad airport. sh: electrical works.; 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frlsh pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frlsh pvc insulated copper conductor single core cable etc as required.a ) group c 2 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 3 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 4 sq.mm + 1 x 4 sq.mm earth wire 4 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frlsh pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.2 x 6 sq. mm + 1 x 6 sq. mm earth wire 5 wiring for light / power plug with 2x4 sq. mm frlsh pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4 sq. mm frlsh pvc insulated copper conductor single core cable for loop earthing as required. 6 supplying and fixing of 25 mm sizes of medium class steel conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 7 supplying and fixing suitable sizegi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 8 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.telephone socket outlet 9 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15 / 16 a switch 10 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15 / 16 a socket outlet 11 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 module ( 75 mm x 75 mm ) 12 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.4 module ( 125 mm x 75 mm ) 13 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required.6 module ( 200 mm x 75 mm ) 14 supplying and fixing of 6 way ( 8 +18 ) , double door , metal, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing, blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 15 supplying and fixing of 12 way ( 2+10 ) , double door, metal , single pole and neutral ( spn ) , metalica mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing , blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 16 supplying and fixing of 6 way ( 2+4 ) , double door, metal , single pole and neutral ( spn ) , metalica mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing , blanking plates etc. as required. ( but without mcb / rccb / isolator ) . 17 supplying and fixing 63a rating, 415 v, 10 ka, 4 pole mcb suitable for inductive load in the existing tpn mcb db complete with connections, testing and commissioning etc. as required. 18 supplying and fixing 63a rating, 240 / 415 v, 10 ka, c curve, dp miniature circuit breaker suitable for inductive loadin the existing mcb db complete with connections, testing and commissioning etc. as required. 19 supplying and fixing of 32 amp rating, two pole, ( one phase and neutral ) , 415 / 240 volts, residual current breaker with overload protection ( rcbo ) , having a sensitivity current 100 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 20 supplying and fixing 5 a to 32 a rating sp mcb, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 21 supply of recessed mounting 2 x 2 led panel luminaire, 36w, ip 20, crca deep drawn housing suitable for 600 mm x 600 mm modular ceiling complete as per technical specifications. 22 installation, testing and commissioning of pre wired, led fitting / compact fluorescent fitting of all types, complete with all accessories etc. directly on ceiling / wall, including connection with 1.5 sq.mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 23 supply of 36 watt led type road / street light with minimum protection level ip 66, pressure die cast housing with epoxy power coated prismatic poly carbonate cover with individual led lenses and complete assembly with led, driver and accessories pre wired up to terminal block i / c suitable mounting accessories etc. as required. 24 fixing of led street light fitting on pole / wall including supply and bending the suitable size gi pipe to the required shape, iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint including connection with 1.5 sq.mm pvc insulated copper conductor single core cable, testing and commissioning complete as required. 25 supply of bldc celling fan with remote control, 1200 mm sweep suitable for 230 volt, with 30 cm down rod, input power range 28 w , speed 350 rpm , air delivery 220 ccm , 5 years warranty and other accessories, canopies, etc. as required. 26 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq.mm frlsh pvc insulated, copper conductor, single core cable etc. as required. 27 supply and fixing of 12 w fully automatic emergency led light having back up time of 3 hours complete with standard accessories all as required. make: prolite or aai preffered make list. 28 supply and installation of astro mini time switch suitable for single phase 240v ac for lighting control based on sunrise / sunset timings by lattitude / longititude settings. ( time switch is to be installed near streetlight db of dvor building ) 29 supply of 230 v , 50 hz industrial heavy duty exhaust fan having 300 mm sweep 1400 rev / minute indculing installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 30 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal / coke and salt as required. 31 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i. pipe from earth electrode including connection with gi nut, bolt, spring, washer excavation and re filling etc. as required. 32 providing and fixing 25 mm x 5 mm gi strip on surface or in recess for connections etc. as required. 33 sitc of three phase neutral surge protection device ( spd ) in the lt panel or any suitable location, type 1+ 2 , 4 module, 3p+ n with inbuilt mcb havingmaximum discharge current 100ka ( 10 / 350 us ) ) , impulse current 8ka with protection level of 0 1.5 kv including allaccessories, conforming to iec 61643 11. 34 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 35 providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, g.i. tube, having single prong at top, with 85 mm dia 6 mm thick g.i. base plate including holes etc. complete as required. 36 supplying and fixing of medium class g.i. pipe of 50 mm dia. ( nominal ) 02 metres length and to be grouted on concrete foundation with installation including base plate , nut bolts , washer etc complete as required on the roof. 37 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 38 providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 39 providing joints by using brazing technique on 25 mm x 3 mm copper strip on surface or in recess for connections to another copper earth strip for interconnection to all earths of lightening arrestors, counterpoise , equipment and electrical power supply earthing etc. as required. 40 supply of following size xlpe insulated and pvc, sheathed aluminum conductor armoured lt power cable of 1.1 kv grade conforming to is 7098:1988 ( part i ) with up to date amendments etc. complete as required.3.5 x 240 sqmm alumimum conductor armoured cable. 41 supplying and laying of following sizedwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc. direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.135 mm dia id 42 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal / dwc hdpe pipe as required.above 185 sq. mm and upto 400 sq. mm 43 supplying and making end termination with brass compression gland and aluminium / copper lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 x 240 sq. mm ( 62 mm ) aluminimum 44 design, sitc of indoor type, floor mounted compartmentalized cubical type panel board of 415 volt ( nominal ) , fabricated out of 2 mm thick crca sheet, free standing and totally enclosed, ip42, confirming to is: 61439, weather proof / dust proof / vermin proof with bottom / top cable entries and cable alleys. the panel board shall be suitable for operation on 3 phase, 4 wire, 50 hz ac supply and with suitable size busbar, earth bar and following switchgear instrumentation and protection devices etc. complete with connections, interconnection, earthing, painting and marking as per site conditions etc complete as required as per the specifications. suuplier must take lt panel design approval from eic before the supply.i: incomer : a ) 160 a, mccb, 4p, 35 37 ka ( icu= 100% ics ) with extended rotary handle and spreaders 02 nos.b ) multi function meter ( shows voltage, current & frequency ) with 3 line lcd / led display of size 96 x 96 mm. 02 nos.c ) indication lamp r, y & b ( led type ) 02 setii: online manual chnage over switch 160a ; 4p ; 25 / 35 ka breaking capacity 1 no.industrial socket ; 63a; 4p 1 no. iii: automatic transfer switch with bypass switch arrangement for manual operation : a ) 200a, 4p, 415v, 50 hz automatic transfer switch.ii outgoing : a ) 100 a, mccb, 4p, 36 ka ( icu= 100% ics ) with extended rotary handle 02 nos. b ) 64a, mccb, 4p, 30 ka ( icu= 100% ics ) with extended rotary handle 03 nos. c ) indication lampr & g ( led type ) 05 set other :a ) 300a copper busbar, 3 phase and neutralb ) inbuilt spd 02 nos. ( type 1 +2 , 4 module , 3 p + n having maximum discharge current 100ka ( 10 / 350 us ) , impulse current 8 ka with protection level of 0 1.5 kv and it shall be installed after the incomer cable suitable with the panel load capactiy ) . c ) necessary ct & control wiring arrangement panel design should be approved from eic before the supply. 45 design, supply , installation , testing and commissioning of natural air cooled three phase voltage stabilizer of 30 kva capacity having input voltage range 340 480 volts and output voltage range : 415 + 1%, frequenct range : 47 53 hz , continuous duty cycle having all the metering to see input output voltage range with rate of correcton : 40v / seccomply with overload proction system and compatible to connect with existing lt panel.design should be approved from eic before the supply. 46 supply and laying of 135 mm dia hdpe pipe with hdd trenchless method direct in ground ( upto 07 meter below ground level ) in all type of soil, coupling of pipe etc complete as per requiement in all aspect. 47 providing , laying and fixing of non pressure np2 class ( light duty ) 150 mm r.c.c pipes with collers jointed with stiff mixture of cement morterin proportion of 1:2 ( 1 cement : 2 sand ) includingcutting / breaking pcc / bituminous area upto suitable depth and 400 mm width andremaking the same as good as previousetc. complete as required. 48 supply and laying of insultion mats of 2 mm thicknessx 1 m wide polysynthetic mats conforming to is 15652 : 2006, class a up to 3.3 kv along with suitable adhesive etc complete as required. 49 constructing masonry chamber 60x60x90 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand ) for lt cable chamber and requires rcc top slab biparting type having minimum 6 inch thickness, 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) to cover the entire area of chamber with proper lifting arrangement , i / c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5. 50 supply installation testing and commissioning of ip65 mi combinable type bus bars junction box with 250 amps ( tinned cu ) bus bars, should be made of high quality polycarbonate pc gfs ( totally insulated class ii ) ( shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material ) , uv resistant, having high grade gasket made of polyurethane, should withstand glow wire test at 9600c, should be flame retardant, materials suitable for outdoor application and the enclosure should have pre moulded knock out for cable entry on side walls and enclosure should have pc hinged option. for cable entry from bottom part a de touchable type pc flange should be fitted with plain wall. the plain wall of flange can be drilled as per cable size. lid screws should be made of polyamide spring loaded half turn type and to open a triangular key or tool will be required. inside enclosure should have lot of self threaded holes so that mounting plate / bus bars can be mounted easily.degree of protection : ip 65 _busbar rating: 250a ( rybn: 30 x 06 ) mm cudimensions : 500 [ l ] x 1075 [ h ] x 630 [ d ] mm_ given cable size : 3.5c x 240 sq.mm al. cable ( loop in / loop out ) mounting type : outdoor / floor mounting ( frp frangible frame ) 51 supply of 5 star rating fully inverter split type air conditioner of 1.5 tr ( minimum iseer 4.5 ) capacity with compressor type rotary / bldc / swing type, different cooling capacities for different cooling needs, fitted withrotary / scrollcompressor of min 05 years warranty, having copper condenser coil, operating for refrigerant r32 eco riendly green gas andindoor unit suitable for wall mounting operation with cordless lcd / led remote, auto restart operation, connecting copper refrigerant pipes ( with suitable nitrile insulation including charging of suitable refrigerant gas, 4c x 4 sq.mm copper cable, drain pipe ) up to 3mtr. and suitable for operating on 230v ±10%, 50hz, single phase, ac , control wiring, thermostat, washable synthetic air filter etc. complete ascapable of performing cooling, dehumidifying, air circulating, filtering functions, stablizer free operation etc. meeting the technical specifications and make as per the list of approved make. 52 installation, testing and commissioning of split type air conditioner of upto and including1.5trcapacity and fixing of refrigerant copper piping ( including extra refrigerant pipe also, if any apart from standard length ) of suitable size for both suction and discharge along with suitable nitrile / thermal insulation andelectrical cable ( 4c x 4 sq.mm ) of size having suitable size of copper conductor for connection from indoor to outdoor unit including charging of suitable refrigerant gas, providing mounting stand for out door unit and equivalent single phase industrial socket ( 20a ) for ac on / off purpose and all suitable necessary accessories complete as per site requirement. 53 supply of extra refrigerant copper piping for 1.5tra.cof suitable size for both suction and discharge along with suitable thermal insulation andelectrical cable of suitable size copper conductor for connection from indoor to outdoor unit and suitable necessary accessories for connection complete as required. ( one length of suction piping , one length of discharge piping and one length of copper wire shall be measured one meter for this item ) 54 supply and fixing of 75mm dia medium class pvc pipe for coveringrefrigerant copper pipingfor both suction , discharge and electrical cable with suitable necessary accessories for pipe connection complete as required. 55 supply and fixing of hard upvc drain pipe of 25 mm dia connection from indoor to outside of wall including bends, sitable insulation , u straps , clamps and necessary accessories for connection etc. complete as required. 56 supply and fixing of 5kva, 15amp / 130v 300v digital electronics voltage stabilizer of wall mounting type with instant start and intelligent time delay provisionssuitable for 1.5 tr split ac units. 57 supply and fixing of smart controller / timer with 4 hr / 8 hr duration, 25a capacity, having ov & uv indication / protection suitable for ac power supply 240 v, 50 hz. etc. complete as required. 58 supply of floor mounted bubble top water dispenser having cold and hot water storage capacity of minimum 3.2 ltr and 1.0 ltr with use of non cfc eco friendly gas refrigrent, cooling capacity minimum 2.5 ltr / hr, heating capacity minimum 5 ltr / hr with cabinet / refrigerator capacity : 20 litres led indicator and 3 faucets ( normal / hot / cold ) mode function with 02 nos , 20 ltr can etc complete as required. 59 supply and laying of 2 core , 1.5 sq. mm . fire survival cable , armoured copper conductor of 600 / 1000 v grade, insulated with specially formulated pvc , coated with special fire resistance materials and overall sheathed with special pvc, with special properties as zero halogen low smoke insulation basic construction as per bs 7846 2009 & cuircuit integrity as per bs 6387 c.w.z / bs en 50200. 60 supplying, installation, testing & commissioning ofconventional fire alarmpanel , 16 x 2 dotmatrixlcd display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per is:2189, complying relevantnational fire alarm code for local fire alarm systemwith mimic diagram for all area / zone covered, complete with all connections. the panel shall have input of 240 volts ac power supply, inbuilt automatic battery charger, 24 volts, 2 x 12 volts, 12 ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. the panel shall be ul listed & fm approved and along with gsm auto dialer facility ( 20 nos min. ) etc. as required. 61 supply, installation, testing & commissioning of ul / en listed ( latest version ) conventionalsmoke detectorwith inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible led, fully coated circuit board, superior rf / transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of lexan ( or polycarbonate ) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications , complete as required. ( cost of plug in common base shall deemed to be included in cost of detectors ) . 62 supply, installation, testing & commissioning of ul / en listed ( latest version ) conventional manual call station ( resetable pull / push type ) suitable for semi flush mounting, ip 54 for indoor use & ip 65 for outdoor use with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test reset lock. manual pull station shall be connected with two wire to slc loop of fire control panel. cover shall be made out of lexan ( or poly carbonate equivalent ) with clear operating instruction and the word fire appearing on the front complete with connections etc. as required and as per enclosed specifications. 63 supply, installation, testing and commissioning of ul / en listed ( latest version ) loop powered addressable hooter cum strobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of min. 90 db to max. 120 db at 1m distance complete with termination etc. as required and as per enclosed specification. 64 sitc of 4.5 kg co2 type automatic fire extingusher with sprinkler head for spot type protection i / c mounting accessories etc complete as required....

Munitions India Limited - Maharashtra

38859228 tender for repairs to damaged electrical high mast and of old flood light fitting at o.f. chanda estate. 1 cat ( a ) items to be supply and fixing 2 dismantling / taking down of existing flood light fitting of any wattage / any size from high mast and deposit of controlling gear box and damaged fitting to store section or as per site location. fitting to be dismantled from high mast as per high mast technical directives and deposit to departmental store. all as per the direction of engineer in charge. 3 s&f, of high quality integrated led flood light with a minimum system lumen 54000 lm @5700k and system wattage not exceeding 480w & for ww only 10% system output reduction will acceptable. thd <10%, power factor >0.95, cri >70.the housing should be of non corrosive high pressure die cast aluminium to with stand extreme environments.it should have corrosion resistant powder coating to pass nss of 500 hrs. with pf >0.95.lifetime of 50k hours @l70. product should be suitable for continuous operation ( 10 12 hrs. per day ) .the ingress protection should be minimum ip 66 with an ik rating of 08.optical and control gear compartments shall be maintainable / replaceable without impacting the led units.the access to the optical and the gear compartment should be separate.while accessing the gear compartment, the optical compartment should not be accessible.the luminaire should have a 20 kv / 10 kv spd duly bolted in the luminaire.the spd should be able to sustain a minimum 15 hitsof 10 ka rating i.e. total of 45 hits across all the three modes as per ieee 62.41.2.the luminaire should have a breather to ensure that air balance inside and outside of the compartment.the luminaire should be of class b serviceability.the wattage of each led should be greater than 1 watt and less than 3 watt.only high power single white led chip with ceramic based suitable for outdoor use is allowed.multi chip, array multi die, mid power, integrated arrays and cob’s are not permitted.suitable nos. of high power led used in the luminaire shall be smd type only of make lgit, lumileds, osram, nichia, and cree & no other make.the luminaire should be capable of withstanding voltage stress of 440v for 8 hrs., should have an auto shutdown @ 325v and have an auto recovery feather.the drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire.fitting make: philips / wipro / oshram. fitting have a breather ensuring a stable optical and thermal management. fitting to be fit on high mast as per site requirement on existing ring mounted system. all the wiring from main junction box terminal ( for lighting control ) point to individual fitting terminal to be done by contractor while installing the fitting. from junction box terminal to individual fitting to be controlled with 3 core round cable of 2.5 sq.mm. stranded copper wire with pvc insulation and pvc sheathed of 300v capacity of any length as per site requirement. fitting to be fixed in such a way that, whole ring support system which is holding the fittings should be tilted / slanted in any direction or position. ring position on aerial condition should be in a flat / level condition, if any extra dummy weight to be given for balancing that work to be carried out by contractor self as per site requirement with all accessories. fittings to cover 3 years warranty periodfrom date of fixing. all as per the direction of eic. 4 s&f, of high quality integrated led flood light with a minimum system lumen 38000 lm @ 5700kand system wattage not exceeding 350w & for ww only 10% system output reduction will acceptable. thd <10%, power factor >0.95, cri >70.the housing should be of non corrosive high pressure die cast aluminium to with stand extreme environments.it should have corrosion resistant powder coating to pass nss of 500 hrs. with pf >0.95.lifetime of 50k hours @l70. product should be suitable for continuous operation ( 10 12 hrs. per day ) .the ingress protection should be minimum ip 66 with an ik rating of 08.optical and control gear compartments shall be maintainable / replaceable without impacting the led units.the access to the optical and the gear compartment should be separate.while accessing the gear compartment, the optical compartment should not be accessible.the luminaire should have a 20 kv / 10 kv spd duly bolted in the luminaire.the spd should be able to sustain a minimum 15 hitsof 10 ka rating i.e. total of 45 hits across all the three modes as per ieee 62.41.2.the luminaire should have a breather to ensure that air balance inside and outside of the compartment.the luminaire should be of class b serviceability.the wattage of each led should be greater than 1 watt and less than 3 watt.only high power single white led chip with ceramic based suitable for outdoor use is allowed.multi chip, array multi die, mid power, integrated arrays and cob’s are not permitted.suitable nos. of high power led used in the luminaire shall be smd type only of make lgit, lumileds, osram, nichia, and cree & no other make.the luminaire should be capable of withstanding voltage stress of 440v for 8 hrs., should have an auto shutdown @ 325v and have an auto recovery feather.the drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire.fitting make: philips / wipro / oshram. fitting should have a breather ensuring a stable optical and thermal management. fitting to be fit on high mast as per site requirement on existing ring mounted system. all the wiring from main junction box terminal ( for lighting control ) point to individual fitting terminal to be done by contractor while installing the fitting. from junction box terminal to individual fitting to be controlled with 3 core round cable of 2.5 sq.mm. stranded copper wire with pvc insulation and pvc sheathed of 300v capacity of any length as per site requirement. fitting to be fixed in such a way that, whole ring support system which is holding the fittings should be tilted / slanted in any direction or position. ring position on aerial condition should be in a flat / level condition, if any extra dummy weight to be given for balancing that work to be carried out by contractor self as per site requirement with all accessories. fittings to cover 3 years warranty periodfrom date of fixing. all as per the direction of eic. 5 s&f, of high quality integrated led flood light with a minimum system lumen output >24000 lm and system wattage not exceeding 210w . thd <10%, power factor >0.95, cri >70. cct 5700, full ip 66 ( without glue ) .protected single piece die cast aluminium housing having pc optical cover with impact resistanceik rating of 07, also has aluminium fins with horizontal line length ( which will be designed as per dust environment ) ensure heat dissipation from the led. high power leds with dual profile lens ( which will help to get maximum area coverage on low wattage ) . which ensures proper distribution of light and suitable for harsh environment led driver should be potted and encapsulated. bis complied driver should voltage stress of 440v for 8 hrs, operating voltage 120 277 voltage. high voltage cut off @325v and have an auto recovery feather. driver shall have 4kv surge protection and feasibility of 10kv external spd housed in luminaire. ) . driver should own manufacturing for service after warranty period. fixture and driver life time of 50k hours @l70.fitting make: philips / wipro / oshram.fitting to be fit on high mast as per site requirement on existing ring mounted system. all the wiring from main junction box terminal ( for lighting control ) point to individual fitting terminal to be done by contractor while installing the fitting. from junction box terminal to individual fitting to be controlled with 3 core round cable of 2.5 sq.mm. stranded copper wire with pvc insulation and pvc sheathed of 300v capacity of any length as per site requirement. fitting to be fixed in such a way that, whole ring support system which is holding the fittings should be tilted / slanted in any direction or position. ring position on aerial condition should be in a flat / level condition, if any extra dummy weight to be given for balancing that work to be carried out by contractor self as per site requirement with all accessories. fittings to cover 3 years warranty period from date of fixing. all as per the direction of eic. 6 s&f, of high quality integrated led flood light with a minimum system lumen output >12000 lm and system wattage not exceeding 100w . thd <10%, power factor >0.95, cri >70. cct 5700, full ip 66 ( without glue ) .protected single piece die cast aluminium housing having pc optical cover with impact resistanceik rating of 07, also has aluminium fins with horizontal line length ( which will be designed as per dust environment ) ensure heat dissipation from the leds . high power leds with dual profile lens ( which will help to get maximum area coverage on low wattage ) . which ensures proper distribution of light and suitable for harsh environment led driver should be potted and encapsulated. bis complied driver should voltage stress of 440v for 8 hrs., operating voltage 120 277 voltage. high voltage cut off @325v and have an auto recovery feather. driver shall have 4kv surge protection and feasibility of 10kv external spd housed in luminaire. ) . driver should own manufacturing for service after warranty period. fixture and driver life time of 50k hours @l70.fitting make: philips / wipro / oshram.fitting to be fit on high mast as per site requirement on existing ring mounted system. all the wiring from main junction box terminal ( for lighting control ) point to individual fitting terminal to be done by contractor while installing the fitting. from junction box terminal to individual fitting to be controlled with 3 core round cable of 2.5 sq.mm. stranded copper wire with pvc insulation and pvc sheathed of 300v capacity of any length as per site requirement. fitting to be fixed in such a way that, whole ring support system which is holding the fittings should be tilted / slanted in any direction or position. ring position onaerial condition should be in a flat / level condition, if any extra dummy weight to be given for balancing that work to be carried out by contractor self as per site requirement with all accessories. fittings to cover 3 years warranty period from date of fixing. all as per the direction of eic. 7 s& fixing of timer, contactor and mcb inside the existing controlling panel box as per site location.following items to be replace inside the high mast controlling panel db for operating high mast after dismantling the damaged controlling wiring and faulty spares1. quartz type analog time switch street light timer operating 240 v ac, 50hz 1 no.2. 3 pole contactor, 16amp. or suitable 240vac 2 no.3. triple pole mcb, 32amp. 440 volts, 50 hz 2no. ( inside high mast1 + inside control panel1 ) 4. single pole mcb 10amp. 1 no. etc.controlling wiring, power wiring of suitable size with other accessories to be used inside the controlling db for high mast operating. incomer and outgoing from controlling panel should be through proper size of connector or suitable terminals.all the electrical errection work to be carried out as per site requirement of ofch with all accessories. all the above new luminaries which is to be fixed on high mast to be checked and positioned to be adjusted as per requirement of ofch. all as per direction of e ic. 8 shifting and fixing of controlling db of high mast to a suitable location as per site requirement. controlling db to be shift from high mast side to a near street light pole side or as per site requirement. following work to be carried during shiftinga. s and fixing of heat shrinkable jointing kit of 25 sq.mm for xlpe / pvc cable ( 3.5 core ) 1no.b. high mast db to be removed from the existing place and to shift desired location with proper concrete foundation.c. proper size of 3.5 core pvc cable / twin core aluminium conductor cableto be drawn from over headl.t. line ( 3 phase ) to db as incomer in g.i pipe as per the site requirement. d. suitable size and capacity of connector to be given inside high mast for lighting and motor control as per site requirement.e. db to be painted with smoke grey colour paint with danger sticker on front side of panel.f. after dismantling the existing db proper levelling to be done to soil surface with underground cable to be laid up to inside the high mast terminal through suitable pipe from the joint as per site requirement.g. checking of all nut blot, steel wire rope for holding high mast, motor, control gear box to be checked and proper lubricant and petroleum jelly to be applied as and where required in high mast as per site requirement with co ordination of ofch representative.all the electrical connection of db to be done as per site requirement with all accessories. all as per direction of e i c. 9 supply and fixing of 2.5 sqmm , 4 core pvc insulated, pvc sheathed flexible aluminium conductor l.t. cable compliance with is 694:2010 standard. cable rated voltage should be 1100v grade. cable to be drawn inside the high mast after removing the old damaged cable of any length. cable one end to be terminated inside the high mast connector and other at top terminal junction box i.e. outside the high mast. the above work to be carried out in different location high masts with all accessories as per site requirement. all as per direction of e i c. 10 s&f, earthing pit complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground ( earth pit not less than 2.25meter deep below ground level ) with top edge of the plate not less than 1.5meter below normal ground level, connected to galvanized earth galvanised iron connected togalvanised earth lead wire 4.0mmdia. by means of bolts, nutsnot more than 7.5 mt. length from earth electrode to test pointand panel / db by means of bolts, nuts, checknuts &washers of galvanized iron or steel all as shown in electrical plate no.3 connected to earth test point with adequate quantity of salt and charcoal dust in earth pit.all as specified or indicated including testing on completion etc ( on testing after completion if the desired earth resistance ( not more than 10 ohm ) not obtained the earthing will be redone at no extra cost. height of earthing pit should be 2 feet above ground level with brick and all civil works accessories like pipe and cover of earth pit chamber etc. all as per direction of engineer in charge....

Department of Higher Education - Maharashtra

38604797 bids are invited for panel light , panel light 1 , enclosure , enclosure 1 , enclosure 2 , ceiling fan , time switch , rccb , led tube , led fixture , led fixture 2 , mcb , mcb 1 total quantity : 1380...

Rural Development Department - Maharashtra

38588000 to supply and erection of electrical material for year 2023 24 at grampanchayat to supply and erection of electrical material for year 2023 24 at grampanchayat kunjirwadi tal haveli dist pune , electrical material , supplying ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt , making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) , supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total6 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 147 kg ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness ( 5 + 2.5 + 2.5 m ) length respectively and total 10 m long with pole cap, base plate in provided foundation ( weight 160 kg ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness ( 5.60 + 2.7 + 2.7 m ) length total 11 m long with pole cap, base plate in provided foundation ( weight 175 kg. ) as per specification no. . oh pl / stp , supplying street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt / bpc , supplying tpmcb 40a to 63a in provided distribution board , supplying dpmcb 40a to 63a, b series ( for lighting ) in provided distribution boardas per specification no. swswr / mcb , supplying insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse , supplying programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying led street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink extrudedaluminium complete per specification nofgodf / fls2. , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extrudedaluminium complete per specification nofgodf / fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fg odf / fls 2. , supplying led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls2 , supplying led street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2. , supplying led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2. , supplying led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , supplying led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , 2 5 17 supplying led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , supplying street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt / bpc ( 2 9 2 ) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb ( 2 9 3 ) , supplying pvc armoured cable 4core 6sq mm , supplying pvc armoured cable 4core 10 sq mm7 1 15 , supplyingpvc armoured cable 2core 10 sq mm , supplying pvc armoured cable 2core 6 sq mm , supplying pvc armoured cable 4core 16 sq mm , supplying pvc armoured cable 4core 25 sq mm , supplying xlpe armoured cable 3½ core70sq. mm. aluminium , supplying xlpe armoured cable 3½ core95sq. mm. aluminium , supplying xlpe armoured cable 3½ core120sq. mm. aluminium , supplying spmcb 6a to 32a, b series ( for lighting ) , supplying dpmcb 6 a to 32 a bseries ( for lighting ) , supplying tpmcb 6 a to 32amp in provided distribution board , supplying fpmcb 40a to 63a in provided distribution board , supplying crimping type aluminium lugs for cable upto 16 sq mm , supplying crimping type coper lugs for cable upto 1.5 to 6sq mm , supplying two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. , supplying mains with2x1.5 sq.mm f.r copperpvc insulated wire , supplying mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no:gma / bw , supplying mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , supplying mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , supplying mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , 25 amp, 32 amp three phase l / t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker ( 1 hours ) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 9 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no.oh pl / opl. , providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl , providing & erecting 10 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 175 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl , providing & erecting 11 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 210 mm a / f, top 90 mm a / f on provided foundation as per specification no. oh pl / opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor forautomatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl / hm ( excluding luminaries ) . , making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no.sw swr / mfp , supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 200 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18 / 20 tube light , lamp holder china clay , lamp holder ( pendent ) , nut bolt , gi wire 10 swg , pole errection , conductor errection , v crosfixing , mcb box metal 4 way , 150watt pcb , 120 watt driver , 150watt pcb , 150 watt driver , 200watt pcb , 200 watt driver...

Rural Development Department - Maharashtra

38515052 supplying electrical materials and repairs maintenance services at. grampanchayat nimgaon, tal. khed, dist. pune , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) , supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying,tpmcb 40a to 63a in provided distribution board , providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) , supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , nut bolt , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , cable joint kit upto 16 sq. mm cable , street light pole box frp , street light pole clamp round type , supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) , servicing and primary maintenance for street light pole.. , light pole painting , 26w led light to 100w led light repairing , old pole shifting , rework and foundation work per pole , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no , supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 , solar battery bracket , solar battery box high quality… , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , distilled water (1 ltr.) , panel frame for old pole , solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. , providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. , supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs , supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) , supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. , supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. , providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep , supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. , dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. , supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. , supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. , supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. , 18 wtt. led bulb , 24 w. led bulb , 30 w. led bulb , supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38401989 to supply and erection of electrical material for year 2023 24 at grampanchayat kunjirwadi tal haveli dist pune , electrical material , supplying ms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt , making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) , supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total6 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 147 kg ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness ( 5 + 2.5 + 2.5 m ) length respectively and total 10 m long with pole cap, base plate in provided foundation ( weight 160 kg ) as per specification no. oh pl / stp , supplying steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness ( 5.60 + 2.7 + 2.7 m ) length total 11 m long with pole cap, base plate in provided foundation ( weight 175 kg. ) as per specification no. . oh pl / stp , supplying street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt / bpc , supplying tpmcb 40a to 63a in provided distribution board , supplying dpmcb 40a to 63a, b series ( for lighting ) in provided distribution boardas per specification no. swswr / mcb , supplying insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse , supplying programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying led street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink extrudedaluminium complete per specification nofgodf / fls2. , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extrudedaluminium complete per specification nofgodf / fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification no fg odf / fls 2. , supplying led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls2 , supplying led street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2. , supplying led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2. , supplying led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , supplying led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , 2 5 17 supplying led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf / fls 2 , supplying street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt / bpc ( 2 9 2 ) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb ( 2 9 3 ) , supplying pvc armoured cable 4core 6sq mm , supplying pvc armoured cable 4core 10 sq mm7 1 15 , supplyingpvc armoured cable 2core 10 sq mm , supplying pvc armoured cable 2core 6 sq mm , supplying pvc armoured cable 4core 16 sq mm , supplying pvc armoured cable 4core 25 sq mm , supplying xlpe armoured cable 3½ core70sq. mm. aluminium , supplying xlpe armoured cable 3½ core95sq. mm. aluminium , supplying xlpe armoured cable 3½ core120sq. mm. aluminium , supplying spmcb 6a to 32a, b series ( for lighting ) , supplying dpmcb 6 a to 32 a bseries ( for lighting ) , supplying tpmcb 6 a to 32amp in provided distribution board , supplying fpmcb 40a to 63a in provided distribution board , supplying crimping type aluminium lugs for cable upto 16 sq mm , supplying crimping type coper lugs for cable upto 1.5 to 6sq mm , supplying two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. , supplying mains with2x1.5 sq.mm f.r copperpvc insulated wire , supplying mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no:gma / bw , supplying mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , supplying mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , supplying mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires , 25 amp, 32 amp three phase l / t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker ( 1 hours ) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 9 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specification no.oh pl / opl. , providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl , providing & erecting 10 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 175 mm a / f, top 70 mm a / f on provided foundation as per specification no. oh pl / opl , providing & erecting 11 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 210 mm a / f, top 90 mm a / f on provided foundation as per specification no. oh pl / opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor for , automatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl / hm ( excluding luminaries ) . , making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no.sw swr / mfp , supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 200 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18 / 20 tube light , lamp holder china clay , lamp holder ( pendent ) , nut bolt , gi wire 10 swg , pole errection , conductor errection , v crosfixing , mcb box metal 4 way , 150watt pcb , 120 watt driver , 150watt pcb , 150 watt driver , 200watt pcb , 200 watt driver...

Rural Development Department - Maharashtra

38306106 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. 68 highmast repairing and maintanance 69 solar highmast as per meda benchmark 70 photo cell sensor automatic on off 71 solar offgrid palnt 72 solar on grid plant 73 flood light 150 w. 74 flood light 200 w. 75 flood light 100 w. 76 solar water pump as per meda benchmark cost 3.0 hp 77 solar water pump as per meda benchmark cost 5.0 hp 78 solar water pump as per meda benchmark cost 7.5 hp 79 solar water pump as per meda benchmark cost 10.0hp 80 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Dr. Babasaheb Ambedkar Marathwada University - Maharashtra

38234789 tender for annual maintenance contract of repair of solar water heating systems (arc 2023 24) , maintenance of repair of solar water heting systems , supplying and erecting hot water storage tank 1000 ltr. capacity with stand ( mnre / meda ) , supplying and erecting hot water storage tank 500 ltr. capacity with stand ( mnre / meda ) , supplying and erecting 16 / 20 ( idod ) mm polyethylene composite pipe , supplying and erecting 20 / 25 mm ( idod ) polyethylene composite pipe , supplying and erecting g.i pipe 20 mm dia b class with resin bonded flap rock wool / glass wool insulation, with necessary material , supplying and erecting g.i pipe 25 mm dia b class with resin bonded flap rock wool / glass wool insulation, with necessary material , supplying and erecting g.i.pipe 15 mm dia. ‘b’ class , supplying and erecting isi mark g.i.pipe 20 mm dia.‘b’ class , supplying and erecting isi mark g.i.pipe 25 mm. dia. ‘b’ class , supplying and erecting iron work for panel board or other purposes , supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater ( 15 / 20 mm. ) . , supplying & erecting solenoid valve size 1 material ss 304 , replacement of old fpc solar water heating panels by new etc solar manifold panels. solar etc manifold ( adequate for capacity 500 lpd ) should have ss inner with 50 nos. etc tube of size 58mm x 1800mm triple layer. tube holders of manifold should be in metal and mounting stand should have adequate strength. ( old panels to be submitted at estate section ) , replacement of old fpc solar water heating panels by new isi marked fpc solar panels. solar fpc panel ( adequate for capacity 125 lpd ) should have cu cu fin and tube assembly with ultrasonic welding. fpc panel should be supplied with mounting stand and installation to existing system tanks. ( old panels to be submitted at estate section ) , supplying & erecting etc tube ( mnre / meda ) ( 58x1800mm ) , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250v 50 cycle a.c. having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating upto 16a to use independently or in conjunction with contractor. , supplying and erecting 58x1500 etc. tubes , supplying and erecting 58x1800 etc. tubes , supplying and erecting 58x2100 etc. tubes , supplying and erecting 47x2100 etc. tubes , supplying and erecting 58mm silicon rubber ring , supplying and erecting 47mm silicon rubber ring , supplying and erecting 500 lpd pvc 3 layer b60 b61tank with stand , supplying and erecting 1 nrv , supplying and erecting manyfold for 58mm x 50 nos , supplying and erecting manifold47mm x 60 nos , supplying and erecting 125 lpd fpc , checking & servicing 300 lpd swhs , checking & servicing 500 lpd swhs , checking & servicing 2000 lpd swhs...

Rural Development Department - Maharashtra

38064200 supplying electrical materials and repairs maintenance services at. grampanchayat khalumbre, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38003871 supplying electrical materials and repairs maintenance services at. grampanchayat wasuli, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. ( 8 1 2 ) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying, tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 29 ) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l / t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying ( including excavation ) 50 mm outside dia. double wall corrugated pipes ( dwc ) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker ( 1 hours ) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol / bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water ( 1 ltr. ) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole ( 125 x 70 mm ) 13.3 kg / mwith provided base plate in provided foundation as per specification no. oh pl / rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7 / 10 swg ( for to 15mtr. long ) with pole clamp, made of 50 x 6 mm ms flat, completeerectedon provided rsj pole. ( add. rs. 25 / per m for extra length beyond 15 m ) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7 / 2.21mm complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 59 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 60 supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets, clamps, insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes, panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding / lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt 65 supplying and erecting aluminium bobbin with g.i. ( shackle ) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall / cable / conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire....

Rural Development Department - Maharashtra

38002584 supplying electrical materials and repairs maintenance services at. grampanchayat sawardari, tal. khed, dist. pune 1 supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) 4 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 supplying,tpmcb 40a to 63a in provided distribution board 6 providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. 7 supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse 8 supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a 9 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 10 1.25 mm crca sheet metal enclosures with 20a. 11 supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) 12 supplying and erectingled street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 13 supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 14 supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 15 supplying & erecting fuse bridges with base h.c. type fuse links 240v 63a 5 10 9 16 supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 17 supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 18 supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 19 supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 20 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 21 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 22 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 23 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 24 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 25 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 26 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 27 25 amp, 32 amp three phase l/t contactor 28 nut bolt 29 2.5 sq. mm multistand copper wire 30 insulation tape 31 water proof tape 32 cable joint kit upto 16 sq. mm cable 33 street light pole box frp 34 street light pole clamp round type 35 supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (dwc) 36 servicing and primary maintenance for street light pole.. 37 light pole painting 38 26w led light to 100w led light repairing 39 old pole shifting , rework and foundation work per pole 40 supply &fixing of shakle hardware with nut bolt 41 supply and installation of mini feeder pillar with stand 42 rcc road cheasling charges with tractor breaker (1 hours) 43 tree triming for overhead line 44 supplying and erecting solar panel comprising highefficiency mono crystalline / multi crystalline photovoltaic cell 40 wp, 12v, with necessary clamps and module frame on existing structure as per specification no 45 supplying and erecting approved makebattery with capacity of 12 v 40 ah with duty cycle 10 12 hrs suitable to charge on pv cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.esd sol/bat 4 3 17 46 solar battery bracket 47 solar battery box high quality… 48 servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning 49 distilled water (1 ltr.) 50 panel frame for old pole 51 solar light fixture with light 9w / 12w aluminim dia casting with charge controller & lithinium battery with auto on / off system.. 52 providing rental basis hydraulic bucket vehicle of highth 14 mtr. and weight capacity 250 kg with driver, oprator and disel etc. for per day basis.. 53 supplying & erecting rolled steel joist girder pole (125 x 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification no. oh pl/rs 54 supplyinganderectingg.i.fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15mtr. long) with pole clamp, made of 50 x 6 mm ms flat,completeerectedon provided rsj pole. (add. rs. 25/ per m for extra length beyond 15 m) 55 supplyinganderectingpoleclamp madefrom50 x 10 mmms flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 56 supplyinganderecting ‘d’ type pole clamps, fabricatedfrom50 x 6 mm ms flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 57 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. eaep 58 supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (gnat) (73.77kg/km) as per specification no. oh con/aac 59 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 60 supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 61 dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 62 dismantling the existing overhead line including g.i. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 63 supplying and erecting metal work in crca sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 64 supplying & erecting ms pole bracket for guarding/lt oh line fabricated from ism channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt 65 supplying and erecting aluminium bobbin with g.i. (shackle) strip, nuts complete. 66 supplying and erecting gi earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws in an approved manner. 67 supplying and erecting mains with isi markwp 2 x 6 sq. mm. 1100 v. grade aluminium pvcinsulatedandpvc sheathed wires on g.i. bearer wire no. 8 swg complete erectedwith required size ofporcelainreelinsulators and 16 swg g.i. binding wire. ...

Directorate Of Municipal Administration - Maharashtra

37928852 to supply electric material for streetlight maintenance at akot municipal council akot to supply electric material for streetlight maintenance at akot municipal council akot , description ( rate should be as per one itemquantity ) , copper wire 1.5 sq mm multistrand , copper wire 2.5 sq mm multistrand , modular swiitch 6 / 10a , ceiling fan 1200 mm , tape bundle box , modular switch box 12 modulecomplete , electronic step regulator , led sq / circular 16 20 watt , led indoor tube light fixture complete , mccb 500v 90 to 150 amp , driver 45 watt , kitkat 63 amp , copper wire 3*20 , aluminium wire 1 / 18 , wall fan , indoor led bulb 18 / 20 watt , led driver 48 watt , tc wire 2*4 sq.mm , ic mainswitch double pole 250 amp 63 amp 1 phasewith h.c type fuse , on load change over switch 16a , 415 / 500 v 3 phase , on load change over switch 63a , 415 / 500 v 3 phase , power contractor 3 pole ac 50 / 60 hz , short light time switch , cooler medium size...

Indian Army - Maharashtra

37890489 bids are invited for electrcal accesories led 10 watt batten fitting sensor light , modular switch 1 way, 16a, 1 module , socket 6 amp, 5 pin, 2in1 , modular switch 2 way, 6a, 1 module , modular white cover plate with frame 1m , modular pvc box 2 module , modular white cover plate with frame 6m , modular white cover plate with frame 4m , modular white cover plate with frame 3m , modular white cover plate with frame 8m , modular pvc box 4 module , modular pvc box 1 module , modular pvc box 6 module , modular white cover plate with frame 2m , time switch off one daily dial 240v,ac,63a , bell electric buzzer , insulation tape 2.5cmx10mtrx0.125mm. , led 3 watt spot light colour , gland 50 to 120 sqmm , wooden screw 75x8mm , cable jointing kit staright through 16 sqmm to 35 sqmm , cable jointing kit staright through 50 sqmm to 95 sqmm , wooden screw 45x8mm , wooden screw 25x8mm , wooden screw 35x8mm , glow plug top 3 pin 15 amp, top 16 amp. , ceiling rose , wooden screw 12x8mm , angle holder , looping box 150x125x100mm , glow plug top 2 pin plug 5 amp, , time light distribution board with cotractor , 32 amp 3 pole, 230v. , pvc casing caping 12x25mm , lugs 10 to 50 sqmm , aluminium strip 25x3.15mm , plastic rowal plug , galvanised 32x6mm , gland 6 to 10 sqmm , lugs 70 to 150 sqmm , hellogrn lamp 500 or1000 watt, double ended , lugs 185 to 300 sqmm , pvc conduit , hdpe pipe 50mm , hdpe pipe 75mm , hdpe pipe 90mm , hdpe pipe 32mm , hdpe pipe 40mm , switch socket combination 15 or16 amp , switch socket combination 5 or6 amp , modular socket, 6a, 2 or3 pin, 2 module , modular socket, 6a or16a, 2 or3 pin, 2 module , bell pushswitch 6 amp , alluminium lugs 95 sq mm , alluminium lugs 120 sq mm , alluminium lugs 150 sq mm , alluminium lugs 98 sq mm , alluminium lugs 240 sq mm , sheet metal enclousere pole without bus bar suitable for rccb 2 pole 25amp , modular switch socket combination 5 or6 amp 3 pin make anchor roma legrand 1 69 total quantity : 7689...

Rural Development Department - Maharashtra

37874411 supply of electrical material supply at g.p. dawlameti , electrical items : , complete cfl bulb (isi) 36 wt crompton , complete cfl bulb (isi) 45 wt crompton , complete cfl bulb (isi) 65 wt crompton , complete cfl bulb (isi) 85 wt crompton , 6 amp switch modular anchor , 6 amp socket modular anchor , 16 amp switch modular anchor , 16 amp socket modular anchor , 12 mod plate modular anchor , 8 mod plate modular anchor , 6 mod plate modular anchor , complete cfl bulb (isi) 85 wt havells , complete led street light fitting 30 wat crompton , complete led street light fitting 45 wat crompton , complete led street light fitting 60 wat crompton , complete led street light fitting 25 wat anchor , complete led street light fitting 45 wat anchor , complete led street light fitting 30 wat philips , complete led street light fitting 45 wat philips , complete led street light fitting 60 wat philips , complete led street light fitting 36 wat syska with day night sensor , complete led street light fitting 45 wat syska with day night sensor , complete led street light fitting 30 wat havells , complete led street light fitting 45 wat havells , complete led street light fitting 60 wat havells , complete led street light fitting 85 wat havells , complete led street light fitting 100 wat havells , cfl holder , cfl bracket pipe , cfl fitting 85 wt br & k2k , cfl fitting 36 wt br & k2k , clamp cement pole , clamp iron pole , tep roll steel grip , wire bundle( 1/18 aluminium ) i.s.i., jhonson , wire bundle( 1.00 copper jhonson ) , wire bundle( 1.50 copper jhonson ) , wire bundle( 2.50 copper jhonson ) , wire bundle( 3.20 copper jhonson ) , service wire i.s.i., national , service wire 4 mm (2 core) national , service wire 6 mm (2 core) national , service wire 8 mm (2 core) national , service wire 10 mm (2 core) national , service wire 10 mm (4 core) national , led bulb 30 watt crompton/orient/bajaj , led bulb 40 watt crompton/orient/bajaj , led bulb 50 watt crompton/orient/bajaj , led street light 90 watt crompton/orient/bajaj , led choke 30 watt , led choke 36 watt , led choke 50 watt , led choke 60 watt , led plate 30 watt , led plate 36 watt , led plate 50 watt , led plate 60 watt , contractor 70 ap 3 phase lnt , contractor 100 ap 3 phase lnt , armoured cable 35 sq mm24 core isi mark , armoured cable 25 sq mm24 core isi mark , armoured cable 10 sq mm24 core isi mark , armoured cable 16 sq mm24 core isi mark , high mast light 100 watt cromton , high mast light 150 watt cromton , aaliuminium ladder 15 ft , aaliuminium ladder 20 ft , main switch 63amp ( ashoka ) , main switch 32amp ( ashoka ) , solar light complete , timer , time switch repairing , contractor reparing , kit kat...

Rural Development Department - Maharashtra

37856896 supply of electrical and electronic materials in the financial year 2023 24 at grampanchayat. hinjawadi. supply of electrical and electronic materials in the financial year 2023 24 at grampanchayat hinjawadi. , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete.(8 1 2) , supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. , providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16 3 2) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation (weight 175 kg.) as per specification no. . oh pl/stp , supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification , supplying,tpmcb 40a to 63a in provided distribution board , providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply. , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplyingh.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv (1 3 29) , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink 2 9 5 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification no fg odf/fls 2 , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) 5 3 3 , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5 3 7 , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board 5 3 14 , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board 5 3 17 , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 7 10 1 , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4 4 3 , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1 3 3 , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , 2.5 sq. mm multistand copper wire , insulation tape , water proof tape , street light pole box frp , cement street light pole clamp , m.s. street light pole clamp , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor , 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor , 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor , 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor , 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series (for lighting) in provided distribution board as per specification no. swswr/ mcb , 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series (for lighting) in provided distribution board as per specification no. swswr/ mcb , 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions (i o ii) with centre off position as per specification no. sw swr/mcbcos , 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr/mcbcos , 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl/cu , 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl/cu , 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl/cu , 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting icdp switch 10a to 63a , cable joint kit for armoured cable 20 upto 120sq. mm cable , gi tar for service wire support with bobine. , kit kat type fuse 16a 32a 63a 120a , taparia tester , spaner set , control panel hrc fuse , supplying and erecting transformer fidder piller , 5 2 19 supplying & erecting street light control panel in powder coated crca 14/16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , shakal insulator , shakal nut bolt nos , cores arm clamps , 2 pin angel , conductor o2 , conductor gnat , moter starters 3 phase. , switch & socket 6a 16a , moter starters 1 phase , 10 sq mm 3 corealuminum cabal. , celling fan 1200mm , wall fan. 400mm , pop led light 30 40.w , angel holder , led bulb 0 50 w. , 12 model gang box vinay adora , 6amp socket vinay adora , 6amp switch vinay adora , 18 model gang box vinay adora , 16amp socket vinay adora , 16amp switch vinay adora , 2.5sq mm wire 90mtr , 1.5sq mm wire 90mtr , 1sq mm wire 90mtr , casing paty 1 , 35x8 pvc rawal plug , 6x19 drywall screw pop , 6amp socket vinay adora , 6amp switch vinay adora , dummy plate vinay adora , 12 model gang box vinay adora , drill machine bosh , star bit , insulation tape box , dp switch , wire striper , l&t 1 phase contactor , l&t 3 phase contactor , 1 phase timer , 10 sq.mmaluminium lugs 100 nos(1 pkt) , wire striper , bend pipe with fittings , 1 1/2 nut bolt 1 kg , o/l relay l&t make,mn2 , dcm & acm tong testermeco model 27 auto , office bell , conntinuty tester , extension box oreva make , digital timer switch(l&t) , steelgrip tap 6.5mtr , water proof tep , 6x13 drywall screw pop , 6x19 drywall screw pop , 10mm alluminiam lugs , 16mm alluminiam lugs , 2.5sq mm copper lugs , 2.5sq mm copper lugs pin typ , 6mm nut bolt , 10mm service cable 50mtr , 35x8 wood screw , 50x8 wood screw pkt , 35x8 pvc rawal plug , 10mm alluminiam lugs pungli , 16mm alluminiam lugs pungli , distil water 1ltr , 1sq mm polycab wire 90mtr bla , 1sq mm polycab wire 90mtr red , 100amp m c c b , contactor 11kv , 125amp m c c b , 2x2 earthing plate , earthing powder , 16a kit kat fuse , 2 core 1.5sq.mm drop wire(180mtr) , 2.5 sq.mm copper multistand cable , megger(meco make) , taparia plier , screw driver set , adjustable plier , elenki set , nose plier , submersible wire 6sq.mm 20 mtr , 3q contactor , nc contactor , 3 hp auto starter , single phase timer , 5 hp auto starter , 10 sq.mm service wire aluminium...

Directorate Of Municipal Administration - Maharashtra

37745599 matheran electrical material supply , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 800 to 900va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 2500 va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs. based on insulated gate bipolar transistor (igbt) technology complete as per specification no. ap inv , supplying, installing, testing and commissioning 11kv hrc fuse 10a to 40a for load break switch with necessary nut bolts complete. , supplying, installing, testing and commissioning 11 kv hrc fuse 63a for load break switch with necessary nut bolts complete. , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.5 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap ac/wac , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7tr to 0.9tr capacity having iseer minimum 3.1 to maximum 3.29 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position in provided recess with wooden frame complete specification no. ap , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7tr to 2.0tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3tr to 1.6tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 5.00 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0tr to 1.2tr capacity having iseer minimum 3.8 to maximum 4.39 suitable to operate on 250v, 50 hz, a.c. supply having 1 no of air handling unit hi wall/floor mounting type complete with refrigerant r32 having copper condenser, minimum 2.5pm filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dba at position as per specification no. apac/ wac , supplying, installing, testing & commissioning ip epabx for 10 extensions complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 6 x 16 extension complete. , supplying, installing, testing & commissioning digital (hybrid) type epabx of 3 x 8 extensions complete. , supplying, installing, testing & commissioning analogue type epabx of 3 x 8 extension complete. , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 2280 to 2850lpm at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 45kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning of main fire pump (mfp / ep) suitable for water discharge of 1600 to 1800 lpm at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 30kw or of suitable kw capacity for manual/automatic operation and consisting of following : (a) horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (ss410 grade), mechanical seal conforming to is 1520. (b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325. (c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/ep , supplying, installation, testing and commissioning 3 phase, 22/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°c at ambient temp max 50°c & min 5°c at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage & frequency (+15% is tol) 1.80 kw, full load loss at rated current 3.00 kw, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 23 degree of protection, cable box arrangement at hv side & bus duct at lv side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & wti scanner with 3 pt 100 sensors, etc. standard accessories complete with test certificate (as per is:11171 & iec 60076 11) with necessary permissions of electrical inspector, as per specification no. ss tr. , supplying, installation, testing and commissioning 3 phase, 11/0.433 kv, 50 hz., 315 kva, indoor type, vacuum cast coil (vcc) dry type cast resin transformer, copper wound , dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oc at ambient temp max 50oc and min 50oc at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to 5% @ 2.5% in +2/ 2 steps, hv variation, class of insulation h/h, method of cooling an, no load loss at rated voltage and frequency (+15% is toi) 1 kw, full load loss at rated current 3.15 kw, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kv peak full wave lightning impulse withstand voltage with complete enclosure having ip 21 degree of protection, cable box arrangement at hv side and bus duct at lv side, with rating and diagram plate, base channel, earthing terminals and wti scanner with 3 pt 100 sensors, etc., standard accessories complete with test certificates (as per is:11171 & is 2026) with necessary permissions of electrical inspector as per specification no. ss tr. , supplying, installation and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter low carbon steel with 250 micron molecular copper bonded earthing rod of length 3m along with 25 kg carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results specification no. ea mobi , supplying, fixing, and configuring modularised multi service router 802.11/a/n/ac unified wave 2.5 ghz, with rj 45 port, supporting 1 to 13 channels for 2.4 ghz, with unified wireless access point complete , supplying, fixing, and configuring 24 ports with 4 (sfp+) port, ethernet managed switch with web view/cli, 6kv surge protection on ethernet port and console port for management in provided rack as per specification no. wgnwc/gbs , supplying, fixing, and configuring 24 ports + 4 (sfp+) port, managed layer 2, poe switch of , 370w, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing, and configuring 20 sfp ports + 4 combo sfp 10/100/1000 base t erected in provided rack complete. , supplying, fixing, and configuring 20 (1g rj45) ports + 4 combo 1g ports + 4 10g (sfp+) ports, layer 3 switch, si image, 6kv surge protection on ethernet port and console port for management erected in provided rack complete. , supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions (i o ii) with centre off position as per specification no. sw swr / mcbcos , supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kva capacity online pure sine wave ups, with backup time of ....... hrs. pwm & igbt based, with 0.8 to unity output pf complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 82.5 kva up to 100 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 62.5 kva up to 82.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 50 kva up to 62.5 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 40 kva up to 50 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 35 kva up to 40 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 25 kva up to 35 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 20 kva up to 25 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 15 kva up to 20 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 125 kva up to 140 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 100 kva up to 125 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of microprocessor based amf panel suitable for diesel generating set of above 10 kva up to 15 kva capacity three phase, 415 volts, 50hz a.c. with all standard features, safeties etc as per specification no. gen amf. , supplying, erecting, testing and commissioning of diesel generating set with standard control panel with alternator of 5 kva continuous rating, single phase, 230v, 50c/s 0.8 p. f. ac supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self excited, selfregulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 1.3 ltr/hr @75% loading. engine and alternator directly coupled on a common fabricated steel base plate with anti vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. the complete set enclosed in acoustic enclosure made of 18 swg crca sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 db at 1.0 m. the engine with first filling of oil, diesel not less than 13 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 14.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 145 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 11.3 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 9.98 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 150 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 7.47 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.9 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 5.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 34.40 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db(a) at 1.0 m, provided with first filling of oil, diesel not less than 300 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.8 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 50 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 3.0 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply, a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption 17.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kva output continuous rating, 3 phase, 415 v, 50c/s 0.8 p. f. a.c supply a totally enclosed air cooled / liquid cooled multi cylinder diesel engine developing suitable bhp at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self excited, self regulated, screen protected alternator with static excitation system running at 1500 rpm as per is 4722 2001 with voltage regulation +/ 5 %, with performance class g2 and maximum fuel consumption of 2.4 ltr/hr @75% loading. both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 swg crca sheet, sound absorbing material to restrict sound level up to 75 db at 1.0 m, provided with first filling of oil, diesel not less than 40 ltr etc. on provided m20 grade cc foundation as per specification no. gen dg , supplying, erecting, testing and commissioning of 6kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 3kva capacity online pure sine wave with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 2kva capacity online pure sine wave, with backup time of ....... hrs. pwm & igbt based ups with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. ap ups , supplying, erecting, testing and commissioning of 28hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 20hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56°c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting, testing and commissioning of 12hp, vrf/vrv air conditioning system outdoor unit (odu) complies type iv oem standards working on hfc refrigerant r410a or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° c, non stop cooling even at 56° c and coefficient of performance (cop) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital vrf/vrv technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415v±10%, 50 hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. cb lt/cu , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable 1100 v 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb lt/al , supplying, erecting & marking spmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 6a to 32a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking spmcb 40a to 63a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 6a to 32a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 6 a to 32 a, b series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & marking dpmcb 40a to 63a, c series with rated short circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw swr/mcb , supplying, erecting & commissioning mdf box 600x600 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 50x50 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 500x500 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 400x400 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 300x300 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 250x250 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 200x200 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 150x150 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning mdf box 100x100 pairs made from min. 1.5mm thick ms sheet as per specification no. wg tw , supplying, erecting & commissioning 4 pole rccb 80a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 4 pole rccb 100a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 63a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 40a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying, erecting & commissioning 2 pole rccb 16/25a, electromagnetic type with 30/100/300 ma sensitivity with earth leakage trip indication complete as per specification no. sw rccb/rccb , supplying table fan of a.c. 230 v. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and hand shield type 3 pin plug top. , supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 volts 50 cycles 1440 rpm with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5a. plug top complete with moisture proof treatment and ‘e’ class insulation. , supplying led concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4w 6w led including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. , supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 star inverter type, stabilizer free operation suitable for operation on 100v/300 v, 50hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. , supplying and plugging 3 m fibre patch cord lc sc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc sc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om4 lszh duplex complete as per specification no. wg coc/fpc , supplying and plugging 3 m fibre patch cord lc lc mm (50) om3 lszh duplex complete as per specification no. wg coc/fpc , supplying and laying rigid steel conduit 16 swg 32 mm dia. with necessary accessories in rcc work/false ceiling/false flooring as per specification no: wgma/cc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , supplying and installing, testing & commissioning of digital (hybrid) type epabx of 6 x 32 extensions suitable upto 96 extensions complete. , supplying and fixing wireless n 150 desktop adapter in provided computer as per specification no. wg nas/lanc2 , supplying and erecting vpit heavy duty copper wound ballast 230v for 80 150w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting vpit compound heavy duty copper wound ballast for 230v for 250w hpsv/mv/mh as per specification no. fg fg/as5. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background. , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / pop as per required to match the background , supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of uv germicidal tube of 8w capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system. , supplying and erecting ultra violet storage type water purifier (ro+uv+uf) with softener for safe drinking water consisting of uv germicidal tube of 8w capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230v, single phase a.c. supply with uv fail & filter change indication system .(for tds more than 200) , supplying and erecting two pole power contactor 230 v, 32 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole power contactor 230 v, 12 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting two pole metal clad changeover switch 240 v, 32 a erected on angle iron/gi frame and duly connected with suitable wire leads complete , supplying and erecting triple pole mini feeder pillar with 500v, 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a with aluminium bus bar erected in 14 swg crca sheet box with supporting angles, self locks, gasket having ip54,ik10 protection and slanting top to be erected on provided foundation complete as per specification no. sw , supplying and erecting t8 fluorescent tube day light 1200mm, 36 w , supplying and erecting t5 24 w energy efficient fluorescent tube. , supplying and erecting street light wall bracket made from 40 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light wall bracket made from 25 mm. dia ‘ g.i. pipe 1.2 m. in total length complete as per specification no. fg bkt/wb , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fg bkt/bpc , supplying and erecting street light bracket for erection of double fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. fgbkt/bpc , supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.ap wh/stwh , supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kwh/24hour/45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kwh / 24 hour / 45°c, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. ap wh/stwh , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. oh pl/stp , supplying and erecting static energy meter with 3 x 240v 50 hz. ac supply 10 to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, (measuring and display trivector, v, i, kw, pf, hz, last month history of kwh and md in kw) with special features like tod, tamper logging, optical communication port & display in absence of power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof pvc wires duly tested by electric supply company. , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 6 ways (6 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 2 ways (2 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting single pole and neutral distribution board (spndb), with 2 ways for incoming and 10 ways (10 poles) for outgoing sp mcbs, with door, 1.2mm thickness surface / flush mounted, ip 43 protection on iron / gi frame as per specification no. sw swr/mcbdb , supplying and erecting shockproof t. switch 16 a porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof piano type switch 250 v, 16 a, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (trs type) pvc insulated copper wire of size 0.5 sq mm 5 m length connected to the point. , supplying and erecting shockproof 6a porcelain base t.switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected , supplying and erecting shockproof 3 pin plug socket 6a with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting shockproof 3 pin plug socket 16a with porcelain base/ flush type erected on filled polypropylene (is:14772 2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting rigid steel conduit 16 swg 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting rigid steel conduit 16 swg 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting rectangular shaped led panel light(1200mm x 300mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6a erected on m.s box made of 16 swg sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed , supplying and erecting recess type, 3 pin plug socket 6a with piano switch 6 a combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads , supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor. , supplying and erecting pvc trunking (pvc casing n capping) of size 40 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc trunking (pvc casing n capping) of size 32 mm with accessories on wall/ceiling as per specification no: wg ma/con , supplying and erecting pvc trunking (pvc casing n capping) of size 25 mm with accessories on wall/ceiling as per specification no: wg ma/con. , supplying and erecting pvc surface modular switch box with double mounting plate for 6 module duly erected , supplying and erecting pvc surface modular switch box with double mounting plate for 4 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 3 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 2 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 16 / 18 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 12 module duly erected. , supplying and erecting pvc surface modular switch box with double mounting plate for 1 module complete duly erected. , supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected. , supplying and erecting pvc surface modular double mounting plate 8 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 6 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 4 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 3 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 2 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 16/18 module complete duly erected. , supplying and erecting pvc surface modular double mounting plate 12 module complete duly erected , supplying and erecting pvc surface modular double mounting plate 1 module complete duly erected. , supplying and erecting pvc slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification no: wg ma/slbox. , supplying and erecting pvc box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification no: wg ma/box. , supplying and erecting pvc box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification no: wg ma/box . , supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “on” and switching “off” street light as per daily sunset and sunrise respectively automatically having 4 digit led continuous time display, relay output 230 v / 10a with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided m.s. box. , supplying and erecting porcelain base iron clad cut out hc type 415v, 63a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 32a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 200a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 16a erected on polished wooden block. , supplying and erecting porcelain base iron clad cut out hc type 415v, 100a erected on polished wooden block. , supplying and erecting pole clamp made from 50x6mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting pole clamp made from 50x10mm ms flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 63a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, , ip 54 and ik10 protection, 45 a tp contactor for automatic switching of luminaires, 2 no 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting outdoor stand mounted feeder pillar for high mast of the same manufacturer with 32a tpn mcb incomer, 24hr astronomical time switch with minimum 5 years battery backup, ip 54 and ik10 protection, 25 a tp contactor for automatic switching of luminaires, 2 no. 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 swg crca sheet box with supporting angles, self lock, gasket and slanting top erected on cc foundation complete. , supplying and erecting one/two way piano type switch 6a./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with s m screws and duly connected. , supplying and erecting modular type two way switch 6a / 10a (2 module), duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type t.v. socket single outlet, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch one way 16 / 20 a, duly erected on provided plate and box with wiring connections complete with neon indicator. , supplying and erecting modular type switch 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type switch 16a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type d.p. switch 32a with indicator, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type buzzer 220 / 250v, duly erected on provided plate and box with wiring connections complete , supplying and erecting modular type blanking plate two module, duly erected on provided plate & box , supplying and erecting modular type bell push with indicator 2 modules 6a / 10a, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell push 6a / 10a duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 6 / 16a fuse unit, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type 3 pin 6a multi socket with safety shutter, duly erected on provided plate and box with wiring connections , supplying and erecting modular type 3 pin 6 / 16a multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 600/650w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (two module) electronic dimmer 1000w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting modular type (one module) electronic dimmer 400 / 450w, duly erected on provided plate and box with wiring connections complete. , supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete , supplying and erecting metal halide lamp double ended 230v, 70 w . , supplying and erecting metal halide lamp double ended 230v, 250 w. , supplying and erecting metal halide lamp double ended 230v, 150 w . , supplying and erecting marine (waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to is 720:2010 , supplying and erecting mains with wp 4 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 6 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 3 x 4 sq. mm. 1100 v. grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with wp 2 x 2.5 sq. mm. 1100 v grade aluminium pvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swg complete erected with required size of porcelain reel insulators and 16 swg g.i. binding wire. , supplying and erecting mains with 4x25 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 3x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting mains with 2x6 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no: wg ma/bw , supplying and erecting mains with 2x1.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no: wg ma/bw , supplying and erecting m.s. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230v a.c. supply with resetting arrangement complete erected on double wooden/ sunmica board. , supplying and erecting lszh armoured multimode optical fibre cable with 6 fibres, core dia 50/125 ?m (om4) suitable up to 10 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. wg coc/ofc , supplying and erecting led strip light 5m length max. 95 w ip20 class having minimum lumens output of 1600 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50 including driver with 1 year warranty. , supplying and erecting led strip light 5m length max. 45 w ip20 class having minimum lumens output of 800 lumens/m, min. efficacy of 90 lumen/w, cri>80, cct upto 5000k, beam angle of 110 deg., thd0.95, operating range of 230 270v, life class of 30,000 hrs. at l70b50, including driver with 1 year warranty. , supplying and erecting led square / circular max. 7w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 770 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led square / circular max. 25 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2750 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 18 w down lighter/ panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 2000 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 14 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1500 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led square / circular max. 11 w down lighter/panel light having pressure die cast aluminium housing, polystyrene diffuser having system lumens output of min. 1200 lumens, min. efficacy of 110 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. , supplying and erecting led panel light(600mm x 600mm) max. 35 w having crca powder coated housing, polystyrene diffuser having system lumens output of min 4200 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting led panel light(600mm x 600mm) max. 30 w having crca powder coated housing, polystyrene diffuser having system lumens output of min. 3600 lumens, min. efficacy of 120 lumen/w, cri>80, cct upto 6500k, beam angle of 120 deg., max. ripple of 5%, thd0.95, operating range of 120 270v, surge protection of 2.5 kv, life class of 50,000 hrs. at l70b50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty , supplying and erecting integrated led street light fitting 85 90w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 9300 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 70 75w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 7700 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 60w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 6600 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 40 to 50w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 4400 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 26 to 30w ip65 & ik08 class having single piece pressure die cast aluminium housing , having system lumens output of min. 2600 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 23 to 25w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 2300 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 18 to 22w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 1800 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg , supplying and erecting integrated led street light fitting 160 170w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 19000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fgodf/fls2. , supplying and erecting integrated led street light fitting 120w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 13000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k,thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led street light fitting 100 110w ip65 & ik08 class having single piece pressure die cast aluminium housing, having system lumens output of min. 11000 lumens, min. efficacy of 110 lumen/w, cri>70, cct upto 6500k, thd0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50,000 hrs. at l70b50, including driver complete with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led post top 45w ip65 & ik10 class having die cast aluminium housing with uv protected polycarbonate diffuser, having system lumens output of min.4500 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 30,000 hrs. at l50b50 , including driver complete with 2 year warranty as per specification no fgodf/fls , supplying and erecting integrated led highbay fitting 135w ip65 & ik08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of min. 20000 lumens, min. efficacy of 145 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 4kv, life class of 50,000 hrs. at l50b50 , including driver complete with 3 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 70w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 8400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 50w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 5000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 30w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 3000 lumens, min. efficacy of 100 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 195w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 23400 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 155w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 18600 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 120w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min.14500 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led flood light fitting max. 100w ip65 & ik07 class having pressure die cast aluminium housing, having system lumens output of min. 12000 lumens, min. efficacy of 120 lumen/w, cri>70, cct upto 6500k, thd0.90, operating range of 140 270v, inbuilt surge protection of 4 kv, life class of 50,000 hrs. at l70b50, including driver with u shaped bracket with 3 years warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 800mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting integrated led bollard cylindrical/cubical shaped 500mm 8w ip65 & ik10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of min. 800 lumens, min. efficacy of 100 lumen/w, cri>80, cct upto 6500k, thd0.90, operating range of 140 240v, inbuilt surge protection of 2 kv, life class of 25,000 hrs. at l50b50, including driver complete with 2 year warranty as per specification no fg odf/fls2. , supplying and erecting ignitor suitable for 230v hpsv lamp 70/150/250/400w as specification no. fg fg/as6 , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 70 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 250 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son t type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head /pin type 230v, 150 w son type. , supplying and erecting hpsv lamp 3 pin bc/screwed cap head / pin type 230v, 70 w son type. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with pvc accessories on wall / ceiling as per specification no: wg ma/con. , supplying and erecting hms pvc conduit frls grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no: wg ma/cc. , supplying and erecting hms pvc conduit frls grade 25 mm dia. with pvc accessories on wall /ceiling as per specification no: wg ma/con. , supplying and erecting gi wire of high purity of required sizes used for earthing or any other purposes on wall with necessary g. i. clamps fixed on wall/cable/ conduit with screws complete. , supplying and erecting gi strip of high purity required size used for earthing on wall and/or any other purpose with necessary gi clamps fixed on wall painted with bituminous paint with joints required. as per specification no ea ep. , supplying and erecting gi sheet 0.8 mm (22 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gi sheet 0.6 mm (24 swg) having zinc coating of 275 microns with galvanization process compliance to is 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. , supplying and erecting gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12w led lamp on provided pipe as per specification no. fg , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, g.l. stay wire 7/8 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. , supplying and erecting g.i. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop insulator, g.l. stay wire 7/10 swg, g.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable ms clamps duly erected in provided c.c. foundations complete. , supplying and erecting g.i. pipe pole ‘b’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. oh pl/gip , supplying and erecting g.i. pipe ‘c’ class erw 75/80 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 65 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. pipe ‘c’ class erw 20 mm dia with necessary fittings complete as per specification no. ff pp , supplying and erecting g.i. fly stay set for pole including straining screw, g.l. stay wire, 7/10 swg (for to 15m long) with pole clamp, made of 50x6mm ms flat, erected on provided rsj pole complete. (add. rs. 25/ per m for extra length beyond 15 m) , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for, 1kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top suitable for with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 4kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160 270v and output voltage 200 250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 300mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting fresh air cum exhaust fan of light duty 250 v a.c. 50 cycles 225mm. 1400 rpm rust proof body & blades, wire mesh, duly erected, complete. , supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting four pole power contactor 430 v, 16 a for time switch complete erected on provided wooden block/ box, with necessary materials. , supplying and erecting flush, shock proof plug socket 6 pin 6a and 16a with switch 16a combined unit erected in recess in 16 gauge m.s sheet box duly painted and connected with earth terminal and leads , supplying and erecting flush type, shockproof plug socket 6 pin 6a and 16a with switch 16a combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with s m screws and duly connected. , supplying and erecting flush type shockproof plug socket 6a & 16a (6 pin) with 16a switch combined with indicator lamp and fuse with gang box on wooden board. , supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225 mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. , supplying and erecting exhaust fan heavy duty 230 v, a.c. 50 cycles 375/380 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 900 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 450 mm. 1400 rpm complete erected in position as per specification no. fg fn/exf , supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fg , supplying and erecting energy saving ceiling fan 230 v a.c. 50 cycles 1200 mm complete erected in position as per specification no. fg fn/cf , supplying and erecting energy saving bldc ceiling fan 230 v a.c. 50 cycles 1200 mm, max. energy consumption of 28w having service ratio (cmm/w) of min. 8 , pf>0.9, thd , supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. , supplying and erecting electronic type driver for outdoor led fittings upto 25w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 76w100w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and th , supplying and erecting electronic type driver for outdoor led fittings 46w75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<1 , supplying and erecting electronic type driver for outdoor led fittings 26w45w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and , supplying and erecting electronic type driver for outdoor led fittings 151w200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. , supplying and erecting electronic type driver for outdoor led fittings 101w150w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd , supplying and erecting electronic ignitor suitable for 230v metal halide lamp 70/150/250/400w (integral or non integral type luminaires as specification no. fg fg/as6 , supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c. supply erected on polished double wooden block/sunmica block of suitable size. , supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. as per specification no. eaep. , supplying and erecting control gear for non integral flood light fittings suitable for 2x250w hpsv/mh lamp with all accessories complete. , supplying and erecting control gear for non integral flood light fittings suitable for 1x400w hpsv/mh lamp with all accessories complete. , supplying and erecting condenser for mv/sv/mh lamp 250w,230v as specification no. fg fg/as7 , supplying and erecting condenser for mv/sv/mh lamp 150w,230v as per specification no. fg fg/as7 , supplying and erecting ceiling rose / batten holder / slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6a. erected on filled polypropylene board or polished double wooden block/ pvc junction box. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting cabin fan of a.c. 230 v. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. , supplying and erecting c type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting c type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. , supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no ea ep. , supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 rpm with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles a.c. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘e’ class insulation. , supplying and erecting acrylic sheet 3 mm thick to be used for covering the crca sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete. , supplying and erecting 75 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 50 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 40 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 30 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) aerial bunched aluminium cable along with necessary accessories for lt distribution on provided lt pole as per specification no. oh cbl/abc , supplying and erecting 20m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 570 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries) , supplying and erecting 16 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3 mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete. specification no. ohpl/hm (excluding luminaries , supplying and erecting 12v/80ah to 88ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/7ah 7.5ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/42ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/26ah smf battery with battery terminal wire, duly charged with 24 months warranty complete , supplying and erecting 12v/200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/180ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete , supplying and erecting 12v/17ah 18ah smf battery with battery terminal wire, duly charged with 12 months warranty complete , supplying and erecting 12v/150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/130ah to 135ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. , supplying and erecting 12v/100ah smf battery with battery terminal wire, duly charged with 24 months warranty complete. , supplying and erecting 12.5 m (clear height) motorized high mast (top 150mm, bottom 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per bsen 10025 s 355/e350 & 3mm thickness, with base plate 25 mm thick x od 520 mm grade as per is 2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, sg dg u clamps, double drum with assembly 250 kg, 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high mast with serial number, factory inspection report/test report of high mast should be provided as per specifications on provided foundation j type stud/bolts with necessary accessories complete as per specification no. ohpl/hm (excluding luminaries , supplying and erecting 12 v/65ah smf battery with battery terminal wire, duly charged complete with 24 months warranty complete , supplying and erecting 11 kv outdoor type gang operated air break, triple pole switch 200 a capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of c class g.l. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground level with necessary clamp. , supplying and erecting 10m hdmi cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin hdmi connectors complete. , supplying and erecting 100 kvar, 440 v 3 phase, 50 hz., contactor logic & intelligent relay micro apfc passive filter panel, consisting of suitable steps of app/mpp type capacitor units with detuned (harmonic filter) reactors of suitable rating , apfc panel shall be compliance to iec 61439 and power quality iec 61921 standard as per specification no cp ed/apfc , supplying and erecting ‘d’ type pole clamps, fabricated from 50x6mm ms flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete. , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification no: wg pw/cw , supplying and drawing of 2x1.5 sq.mm. frlsh grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification no wg pw/sw , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12 exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying 230/250v, 50hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12 exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dba at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. ap wcr/dac , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(ue), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating xlpe insulated, galvanised steel formed wire armoured (strip) cable 11 kv(e), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. cb ht , supplying , erecting & terminating 11 kv(e), 3 x 70 sq. mm., aluminium conductor xlpe insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. cb ht , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & laying (including excavation) half round reinforced cement concrete pipe of is 458:2003 np 2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete , supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification no. cb sb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 300 x 200 x 150 mm complete on pole as per specification no. cb , supplying & erecting water tight terminal box of 1.6 mm (16 gauge) crca sheet of size 150 x 100 x 100 mm complete on pole as per specification no. cb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), spmcb of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (horizontal busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 4 ways /12 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), sp/tp mcbs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, ip 43 protection on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb , supplying & erecting triple pole and neutral distribution board (tpndb), 3 pole/4 pole mccb as incomer & outgoing sp mcb (36 poles) or tp mcb of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/gi frame (vertical busbar type) as per specification no. sw swr/mcbdb1 , supplying & erecting three phase, 415v, street light control panel up to the max load of 6kw, tpn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting three phase, 415v, street light control panel up to the max load of 12kw, tpn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 4 pole contactor up to 60a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having ip54,ik10 protection, 2 pole contactor up to 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box. , supplying & erecting single pole cut point channel set of for 11kv ht oh line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. , supplying & erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ cc foundation. , supplying & erecting single phase, 240v, street light control panel up to the max load of 12kw, spn mcb 63a, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, on/off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. , supplying & erecting single compression type brass cable glands for 4 core 35 sq.mm./3 core 50 sq.mm. for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for xlpe armoured cable as per specification no. cb gl , supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. , supplying & erecting ms pole bracket for lt oh conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from ism channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting ms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. oh pl/bkt , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 2.25 kw/3 hp with discharge 600/110 litres per minute (lpm) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415v, three phase 50 cycles a.c. supply of 1.5 kw/2 hp with discharge 600/140 litres per minute (lpm) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 5.625 kw/7.5 hp with discharge of 780/170 litres per minute (lpm) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 415 v, three phase 50 cycles a.c. supply of 3.75 kw/5 hp with discharge 715/200 litres per minute (lpm) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting minimum three & above star rated centrifugal water pump (monoblock), 230v, single phase 50 cycles a.c. supply of 1.125 kw/1.5hp with discharge 198/50 litres per minute (lpm)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided c.c. foundation as per specification no. wp cgp , supplying & erecting integral post top lantern fixtures (mushroom type) suitable for led lamp upto 12 w consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (light house type) suitable upto led 18 w lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. fg odf/ptl , supplying & erecting integral post top lantern fixtures (globe type) suitable for led lamp upto 12 w consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. fg , supplying & erecting inline d.p. structure for 11/0.415kv, 63kva transformer with rsj pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of crca sheet 16 swg with 4 pole mccb 100a as incomer & 6 nos. 63a kitkat/mccb for outing circuits. transformer d.p. structure includes the a.b. switch 200a, d.o. fuse set & l.a. set. 2 nos. top channel of size 100x50mm for erection of a.b. switch & 2 nos. base channel of size 100x50mm for erecting transformer channel of size 75x40mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50x50x6mm for erecting distribution box, transformer belt etc. as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 200 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 300 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire. d.p. structure shall be erected in c.c. foundation complete. , supplying & erecting inline d. p. structure for 11/0.415 kv, 100 kva transformer with r.s.j. pole 2 nos. of size 100 x 116 mm x 11 mtr. long with suitable distribution box of c.r.c.a. sheet 16 swg with 4 pole mccb 200 amps as incomer & 6 nos. 100 amps kitkat / mccb for out going circuits. transformer d.p. structure includes the a. b. switch 200 amps, d.o. fuse set & l.a. set. 2 nos. of top channel of size 100 mmx 50 mm for erection of a.b. switch & 2 nos. base channel of size 100 mm x 50 mm for erecting transformer channel of size 75 x40 mm for erecting d.o. fuse set, l.a., a.b. switch handle etc. angle of size 50 x 50 x6 mm for erecting distribution box , transformer belt etc.as per drawing (min. 124 kg. iron work ) with necessary clamps, nut bolts. v cross arm, top clip, insulators etc. complete with caution board & barbed wire, d.p. structure shall be erected in c.c. foundation complete , supplying & erecting g.i. pipe ‘a’ class 75 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 50 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 40 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting g.i. pipe ‘a’ class 25 mm dia. erected for enclosing xlpe armoured cable on wall/pole as per specification no. cb ce , supplying & erecting fully automatic star/delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. , supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification no. cb sb , supplying & erecting four pole on load change over switch, 415v, 63a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 40a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 32a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3 . , supplying & erecting four pole on load change over switch, 415v, 315 320a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 200a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 160a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting four pole on load change over switch, 415v, 100a, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category ac23a complying to is/iec 60947 3 part 1/3. , supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 4 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 2.5 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting flat flexible 3 core 10 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 h.p. , supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 h.p. , supplying & erecting d.o.l starter suitable for 250 v, single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 h.p. , supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification no. cb cl/cu , supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification no. cb cl/al , supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification no. cb cl/al , supplying & erecting crca sheet metal enclosures of 1.2mm thickness with 30 a, 3 pin plug & earth socket and 30a, 3 pin plug top with 30a triple pole mcb having rated short circuit breaking capacity (icn) 10ka complete erected on angle iron / gi frame. , supplying & erecting co axial copper cable low voltage grade tri shielded rg11 as per specification no. wg tw , supplying & erecting co axial copper cable low voltage grade tri shielded rg , supplying & erecting cast iron cable indicator plate buried along with route of cable for pvc / xlpe armoured cable as per specification no. cb cip , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 hp consisting of star delta starter having relay range 9 14 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting automatic control panel for 3 ph, 415 volt, /centrifugal pump set up to 10 15 hp consisting of star delta starter having relay range 13 22 amp, s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc. , supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e , supplying & erecting 14w, 230v integral type led lamp suitable for b 22 / e27 base. , supplying & erecting 10 12w, 230v integral type led lamp suitable for b 22 / e 27 base. , supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly al laminate moisture barrier, laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with fr pvc, conforming to itd specification s/ws 113c laid in provided pvc casing capping/conduit as per specification no. wg tw , supplying & erecting 0.5 mm dia, copper jumper wire as per specification no. wg tw , supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. , supply and erecting 9m (clear height) fixed type high mast (top 100mm, bottom 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. oh pl/opl (excluding luminaires). , rewinding the motor of the exhaust fan 900 / 1400 rpm 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year , rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. , rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for original speed and consumption with guarantee for 1 year including transportation from site and back , rewinding of electric motor upto 1 h.p. single phase up to 1400 rpm of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year. , rewinding of electric motor up to 1 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 7.5 h.p. upto 10 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea , rewinding of electric motor above 5 h.p. upto 7.5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 3 h.p.upto 5 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 2 h.p. upto 3 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , rewinding of electric motor above 1 hp upto 2 h.p. three phase up to 1400 rpm of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year , providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. , providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no. ea ep , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per specification no. ea ep , providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover with minimum 25 kg carbon based environment friendly back fill ground enhancing compound complete with all materials, testing & recording the results as per specification no ese la , providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 kilogram). , providing and erecting heat shrinkable indoor termination kit for 11 kv ( e ) xlpe ht cable 3x up to 95 sq. mm. with necessary material as per specification no. cb jt/ht , providing and erecting galvanised 1000mm single arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing and erecting galvanised 1000mm double arm sword type bracket with frp dome and ball as per specification no. oh pl/pbkt , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 400 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 300 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 200 mm width & 100 mm height comprising all required standard accessories. , providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg (1.6 mm thick) gi sheet of 150 mm width & 100 mm height comprising all required standard accessories , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 8 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no sw swr/mccbpb. (excluding mccbs) , providing & erecting floor/wall mounting, mccb panel board, with door, suitable for four pole incoming 250a, 12 ways four pole outgoing, up to 100 a mccbs on iron frame, as per specification no. sw swr/mccbpb. (excluding mccbs) , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 70 to 95 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 25 to 50 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 2.5 to 16 sq mm., with necessary material as per specification no. cb jt/lt , providing & erecting epoxy straight through joint outdoor/indoor for lt xlpe armoured cable 120 to 185 sq. mm., with necessary material as per specification no. cb jt/lt , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm a/f, top 100 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl. , providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 3 pole mccb, 415 v, 100a, rated short circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line load bias in provided enclosure/panel as per specification no. sw swr/mccb , providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specification no. oh pl/opl , providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm a/f, top 90 mm a/f on provided foundation as per specification no. oh pl/opl , point wiring in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/fan/bell in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire with flush type switch and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for light/bell/exhaust fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg , point wiring for light/bell concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/cw , point wiring for independent plug, concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, flush type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for independent plug in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e ) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in pvc trunking (casing capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan in 20 mm frls grade hms pvc conduit with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no: wg pw/sw , point wiring for ceiling fan concealed type in min 20 mm frls grade hms pvc conduit with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw/c , point wiring for ceiling fan (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. (2+1e) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wg pw/hw , making trench in soft soil having 0.9m depth and minimum 0.3 m width as per is for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kv to 11 kv complete as per specification no. cw exn ctr , making trench in hard murum/tar road having 0.75 m depth and minimum 0.3mtr width as per is for laying provided cables up to voltage level 1.1kv cable complete as per specification no. cw exn ctr , making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick m 10 pcc at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. external surface duly plastered by 12 mm thick including watering etc complete , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical gi pole). , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical gi pole). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). , making m 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) , making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). , excavating hard rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. , concealing of provided g.i. pipe/h.g. screwed conduit/pvc pipe in wall/floor/false ceiling complete as per specification no:wg pw/cw , making m 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 t/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical gi pole)....

Rural Development Department - Maharashtra

37705211 tender for providing, erecting and supplying various different electric material for 1 year@grampanchayat lonikalbhor , electric material this rate please mentioned include gst invoice shall be prepared with gst tax whatever applicable on material rate are mentione with gst , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. , supplying & erectingms pole bracket for guarding / lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl / bkt , making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total6 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation ( weight 147 kg ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness ( 5 + 2.5 + 2.5 m ) length respectively and total 10 m long with pole cap, base plate in provided foundation ( weight 160 kg ) as per specification no. oh pl / stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness ( 5.60 + 2.7 + 2.7 m ) length total 11 m long with pole cap, base plate in provided foundation ( weight 175 kg. ) as per specification no. . oh pl / stp , supplying and erecting street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt / bpc , supplying, tpmcb 40a to 63a in provided distribution board , supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution boardas per specification no. swswr / mcb , supplying and erecting insulated d.p. switch surface type / flush type 32a 240vwith indicator lamp & fuse , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm ( 50 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink bajaj , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification nobajaj. fgodf / fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls2 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sinkbajaj , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2. , supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf / fls 2 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf / fls 2 , 2 5 17 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf / fls 2 , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specificationjno. fg bkt / bpc ( 2 9 2 ) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt / wb ( 2 9 3 ) , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 2core 6 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying & layingpvc armoured cable 4core 25 sq mm , supplying, erecting & terminating xlpe armoured cable 3½ core70sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core95sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous , supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) , supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole , supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no:gma / bw , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l / t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker ( 1 hours ) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75 / 80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 13 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 130 mm a / f, top 70 mm a / f on provided foundation as per specificationbajaj no.oh pl / opl. , providing & erecting 9 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 155 mm a / f, top 70 mm a / f on provided foundation as per specification bajajno. oh pl / opl , providing & erecting 10 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 175 mm a / f, top 70 mm a / f on provided foundation as per specification bajaj no. oh pl / opl , providing & erecting 11 m high ( clear height ) galvanised octagonal pole with foundation bolts having bottom of 210 mm a / f, top 90 mm a / f on provided foundation as per specificationbajaj no. oh pl / opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise / lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m ( clear height ) high mast ( top 150mm, bottom 360mm ) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl / hm ( excluding luminaries ) . , making cement concrete foundation including excavation ( 60 x 60 ) cm x deep 1 / 6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. ( for above 9 m poles ) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no. sw swr / mfp , supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , supplying and erecting regular / standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. fg fn / cf , supplying and erecting regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position as per specification no. fg fn / cf , supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 150 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 100 w bulb , 200 w bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18 / 20 tube light , lamp holder china clay , lamp holder ( pendent ) , rsj pole 9 mtr , v cross arm 22 kv , cut pont set 22 kv , pin insulater22 kv , disc insulater 22 kv , nut bolt , conductor 55 sq mm aac , ht stay set , lt stay set , stay wire , gi wire 8 swg , pole errection , conductor errection , v crosfixing , cutpoint fixing , mcb box metal 4 way , supply of tiranga pole as per sepcifucation 139.7mm od pipe 3mtr 114.3mm od pipe 1mtr 03 nos 88.9mm od pipe 2 mtr total 8 mtr pole , gst charges...

Indian Army - Maharashtra

37655136 bids are invited for em and br two mix mse casing capping double lock isi marked 20mm make pressfit , casing capping double lock isi marked 25mm make pressfit , ceiling rose surface backelite with 3 terminals make anchor pressfit , heating element 2 kw make racold bajaj havells , heating element 1.5 kw make racold bajaj havells , lt cable jointing kit heat shrink 25 sqmm 3 and half core straight through make pedilite super seal 3m m seal , lt cable jointing kit heat shrink 35 sqmm 3 and half core straight through make pedilite super seal 3m m seal , lt cable jointing kit heat shinkable 50 sqmm 3 half core straight through make pedilite super seal 3m m seal , lt cable jointing kit heat shinkable 70 sqmm 3 and half core straight through kit make pedilite super seal 3m m seal , lt cable jointing kit heat shinkable 95 sqmm 3 and half core straight through make pedilite super seal 3m m seal , lt cable jointing kit heat shinkable 120 sqmm 3 and half core straight through make pedilite super seal 3m m seal , mcb dristribution board spn 4 way single door make legrend havells l and t , mcb dristribution board spn 8 way double door make legrend havells l and t , programmable time switch digital astronomical type make gec scheider , pvc switch board 10 inch x12 inch make presfit royal glossy clasic , pvc switch board 8 inch x 10 inch make presfit royal glossy clasic , rawal plug 100 nos box 25 mm x 8 g , flexible wire copper 2 core twisted size 24 0 point 20 in 100 mtr roll make havells rr finolex , foot valve with neoprene ball of size 80 mm flange type make normax , foot valve with neoprene ball of size 100 mm flange type make normax , gi barrel nipple 50 mm x 100mm long make jindal gst r brand kriti , gland packing 8 mm dia make charminar , gland packing 16mm dia make charminar , socket reducer 40x20 mm make jindal gst r brand kriti , socket reducer 40x25 mm make jindal gst r brand kriti , socket 50 mm with analog type watermeter 50 mm bore and 1 5250 mm with analog type wa...

Rural Development Department - Maharashtra

37581230 providing supplying erectiong various material for 1 year at grampanchayat(gp fund) providing supplying erectiong various electric material for development for 1 year at grampanchayat kadamwakwasti haweli(gp fund) , electric material this rate please mentioned include gst invoice shall be prepared with gst tax whatever applicable on material rate are mentione with gst , supplying and erecting modulartype switch6a / 10a isimark approved make duly erected on provided plate and box with wiring connections complete. , supplying & erectingms pole bracket for guarding/lt oh line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. oh pl/bkt , making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total6 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5 + 2.5 + 2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. oh pl/stp , supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation (weight 175 kg.) as per specification no. . oh pl/stp , supplying and erecting street light bracket for erection of single fitting on tubular welded pole with 40 mm. dia 1.0 m long “b” grade g.i. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. fg bkt/bpc , supplying,tpmcb 40a to 63a in provided distribution board , supplying, erecting & marking dpmcb 40a to 63a, b series (for lighting) in provided distribution boardas per specification no. swswr/mcb , supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse , supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively , 1.25 mm crca sheet metal enclosures with 20a. , supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erecting pvc insulated pvc round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv , supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink bajaj , supplying and erecting led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification nobajaj. fgodf/fls2. , supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting suitable for above 70w 75 lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls2 , supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sinkbajaj , supplying and erecting led street light fitting 100w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting 120 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2. , supplying and erecting led street light fitting 150 w, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification bajaj no fg odf/fls 2 , supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf/fls 2 , 2 5 17 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specificationbajaj no fg odf/fls 2 , supplying and erecting street light bracket made from 40 mm. dia ‘b’ class g.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specificationjno. fg bkt/bpc(2 9 2) , supplying and erecting street light wall bracket made from 25 mm. dia ‘b’ class g.i. pipe 1.2 m in total length complete as per specification no. fg bkt/wb(2 9 3) , supplying & layingpvc armoured cable 4core 6sq mm , supplying & layingpvc armoured cable 4core 10 sq mm7 1 15 , supplying & layingpvc armoured cable 2core 10 sq mm , supplying & layingpvc armoured cable 2core 6 sq mm , supplying & layingpvc armoured cable 4core 16 sq mm , supplying & layingpvc armoured cable 4core 25 sq mm , supplying, erecting & terminating xlpe armoured cable 3½ core70sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core95sq. mm. aluminium conductor , supplying, erecting & terminating xlpe armoured cable 3½ core120sq. mm. aluminiumconductor withcontinuous , supplying, erecting & marking spmcb 6a to 32a, b series (for lighting) , supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) , supplying, erecting & marking tpmcb 6 a to 32amp in provided distribution board , supplying, erecting & marking fpmcb 40a to 63a in provided distribution board , supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete , supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. , supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole , supplying & erecting mains with 2x4 sq.mm f.r copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no:gma/bw , supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 , supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire , 25 amp, 32 amp three phase l/t contactor , insulation tape , water proof tape , cable joint kit upto 25 sq. mm cable , cable joint kit upto 35sq. mm to 95 sq mm cable , cable joint kit upto 120sq. mm to 185 sq mm cable , cement street light pole clamp with nut bolt , m.s. street light pole clamp with nut bolt , servicing and primary maintenance of street light pole 1 visit per month pole included and also call basis. checking all wire connections, nut bolt tighting, lugs connection. old light changing & service wire conection labour works etc. , supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(dwc) of hdpe for enclosing cable below ground/road surface, to required depth complete. , servicing and primary maintenance for street light pole. , light poles painting in silver colour , 26w led light to 100w led light repairing , old pole shifting, rework and foundation work per pole etc. , supply &fixing of shakle hardware with nut bolt , supply and installation of mini feeder pillar with stand , rcc road cheasling charges with tractor breaker (1 hours) , tree triming for overhead line , supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete. , supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 4 pole contactor upto 60 a, with maintenance mode to switch on street lights during time of repairs with energy consumption data recording for analysis and lcd display for energy monitoring with numeric key pad in provided box complete , servicing and primary maintenance of solar light pole 1 visit in month included and also call basis. checking all wire connections, nut bolt tighting, lugs connection, timer working condition and panel cleaning , supplying, installing, testing and commissioning solar street light pole comprising of 9 w led fitting, 12v 18ah maintenancefree lithium battery, min. 40 wp spv module, ms powder coated battery box weather proof, mounted on 75/80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esd sol stl ( with 5 years warrantee ) , 4 3 13 supplying, installing, testing and commissioning solar street light pole comprising of 12w x 2 nos. led fittings, 12v min. 100ah maintenance free lithium battery, min. 120wp spv module, ms powder coated battery box weather proof, mounted on 75/80 mm dia. b grade gi pole of 6 m. height along with brackets, foundation, earthling and necessary accessories complete. specification no. esdsol stl , providing rental basis hydraulic bucket vehicle of highth 13 mtr. and weight capacity 200 kg with driver, oprator and disel etc. for per day basis.. , providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm a/f, top 70 mm a/f on provided foundation as per specificationbajaj no.oh pl/opl. , providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm a/f, top 70 mm a/f on provided foundation as per specification bajajno. oh pl/opl , providing & erecting 10 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 175 mm a/f, top 70 mm a/f on provided foundation as per specification bajaj no. oh pl/opl , providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm a/f, top 90 mm a/f on provided foundation as per specificationbajaj no. oh pl/opl , supplying and erecting outdoor stand mounted feeder pillarfor highmast of the same manufacturer with 63a tpn mcb incomer, single dial timer switch, 45a tp contactor for automatic switching of luminaries, 2 nos 9a contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 swg crca sheet box powder coated with supporting angles, self lock, gasket and slanting top erected with cc foundation complete , supplying and erecting 12.5 m (clear height) high mast (top 150mm, bottom 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specificationbajaj no. oh pl/hm (excluding luminaries ). , making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) , supplying and erecting mini feeder pillar triple pole with 200a fpmccb as incomer and 2 outgoing circuits with hrc fuse base and cartridge of 100a consists of aluminium bus bar 500 v 200 a complete erected in 14 gauge crca sheet box with supporting angles, self locks, gasket and slanting topto be erected on provided foundation as per specification no. sw swr/mfp , supplying & erecting street light control panel in powder coated crca 14/16 swg sheet, outdoor type, single phase, 240 v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, spn mcb 63 a auto/manual selector switch,on/off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation complete. , providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ea ep , providing pipe type earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rod complete with all materials as per specification no. ea ep , supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. fg fn/cf , supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. fg fn/cf , supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. , 36 watt pcb , 36 watt driver , 50 60 watt pcb , 50 60 watt driver , 70watt pcb , 70 watt driver , highmast repairing 100 150 watt , service wire 4sq.mm isi mark 2 core , service wire 6 sq.mm isi mark 2 core , service wire 10 sq.mm isi mark 2 core , frp box of size 300 x200 x125 mm 2.7mm thickness , 12w led bulb , 14w led bulb , 18w led bulb , 100 w bulb , 200 w bulb , 16 amp kitkat fuse , 63 amp kitkat fuse , servie reel , retrofit t8 led 18/20 tube light , lamp holder china clay , lamp holder (pendent) , rsj pole 9 mtr , v cross arm 22 kv , cut pont set 22 kv , pin insulater22 kv , disc insulater 22 kv , nut bolt , conductor 55 sq mm aac , ht stay set , lt stay set , stay wire , gi wire 8 swg , pole errection , conductor errection , v crosfixing , cutpoint fixing , mcb box metal 4 way , gst charges...

Directorate Of Municipal Administration - Maharashtra

37548901 annual work for supplying of electrical material for year 2023 24 1 items 2 supplying of electrical material to municipal council, buldana 3 supplying and erecting crca / die cast aluminium powder coated housing led panel light ( slim edge lit ) square / round shape suitable for 19 to 24 w with provision for plane front frame with translucent cover fixed to the housing complete. 4 supplying and erecting square / round shaped crca / die cast aluminium powder coated housing led panel ( slim edge lit ) light suitable for 13 to18w with provision for plane front frame with translucent cover fixed to the housing complete. 5 supplying and erecting t 5 led tube light complete. 6 supplying pvc armoured cable 4 core 16 sq mm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 7 supplying pvc armoured cable 3 ½core 35sqmm aluminium conductor with continuous5.48 sq mm ( 12 swg ) g.i. earth wire complete erected withglands& lugs. 8 supplying mains with isi mark wp 2×2.5 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 9 supplying mains with isi mark 1 sq.mm. aluminium pvc insululated wire. 10 supplying mains with isi mark wp2×4 sq.mm. 1000v. grade aluminium pvc insulated and pvc sheathed wires on gi bearer wire. 11 supplying 3 phase 100 amp with isi mark contactor 12 supplying and erecting quartz electronic time switch having 24 hour dial to work on 250v 50cycle a.c. 13 supplying & erecting approved make 500v 100a porcelain base neutral link complete erected in provided m.s. box with hrc fuse cartridge 500v 100a 14 supplyingcabin fan of a.c. 230 v. 50 cycles 400 mm.sweep complete with necessary brackets for fixing cabin fans, wire etc. 15 supplying regular / standard model ceiling fan of 900 / 1050 mm. sweep complete erected in position. 16 generator servicing and repairing for 25 kva generator. 17 supplying and erecting 12 v / 100ah tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 18 supplying and erecting split type room airconditioning unit 1 tr 5 star capacity 250v, 50 cycles, a.c. supply having 1 no of air handling unit hi wall / floor mounting type complete at position. 19 suppyling and erecting mcb rating 40 63 amp 20 supplying and erecting isolator rating 40 63 amp 21 supplying and erecting street light panel with contactor , timer , mcb isolator complete ( rating 100 amp ) ...

Rural Development Department - Maharashtra

37383362 supply of electric material for the year 2023 24 at gp khapri rly ( kalkuhi ) block nagpur , electrical items : , complete cfl bulb ( isi ) 36 wt crompton , complete cfl bulb ( isi ) 45 wt crompton , complete cfl bulb ( isi ) 65 wt crompton , complete cfl bulb ( isi ) 85 wt crompton , complete cfl bulb ( isi ) 36 wt philips , complete cfl bulb ( isi ) 45 wt philips , complete cfl bulb ( isi ) 65 wt philips , complete cfl bulb ( isi ) 85 wt philips , complete cfl bulb ( isi ) 36 wt havells , complete cfl bulb ( isi ) 45 wt havells , complete cfl bulb ( isi ) 65 wt havells , complete cfl bulb ( isi ) 85 wt havells , complete led street light fitting 30 wat crompton , complete led street light fitting 45 wat crompton , complete led street light fitting 60 wat crompton , complete led street light fitting 85 wat crompton , complete led street light fitting 100 wat crompton , complete led street light fitting 30 wat philips , complete led street light fitting 45 wat philips , complete led street light fitting 60 wat philips , complete led street light fitting 85 wat philips , complete led street light fitting 100 wat philips , complete led street light fitting 30 wat havells , complete led street light fitting 45 wat havells , complete led street light fitting 60 wat havells , complete led street light fitting 85 wat havells , complete led street light fitting 100 wat havells , cfl holder , cfl bracket pipe , cfl fitting 85 wt br & k2k , cfl fitting 36 wt br & k2k , clamp cement pole , clamp iron pole , tep roll steel grip , wire bundle ( 1 / 18 aluminium ) i.s.i., jhonson , wire bundle ( 1.00 copper jhonson ) , wire bundle ( 1.50 copper jhonson ) , wire bundle ( 2.50 copper jhonson ) , wire bundle ( 3.20 copper jhonson ) , service wire i.s.i., national , service wire 4 mm ( 2 core ) national , service wire 6 mm ( 2 core ) national , service wire 8 mm ( 2 core ) national , service wire 10 mm ( 2 core ) national , service wire 10 mm ( 4 core ) national , led bulb 30 watt crompton / orient / bajaj , led bulb 40 watt crompton / orient / bajaj , led bulb 50 watt crompton / orient / bajaj , led street light 90 watt crompton / orient / bajaj , led choke 30 watt , led choke 36 watt , led choke 50 watt , led choke 60 watt , led plate 30 watt , led plate 36 watt , led plate 50 watt , led plate 60 watt , contractor 70 ap 3 phase lnt , contractor 100 ap 3 phase lnt , armoured cable 35 sq mm24 core isi mark , armoured cable 25 sq mm24 core isi mark , armoured cable 10 sq mm24 core isi mark , armoured cable 16 sq mm24 core isi mark , high mast light 100 watt cromton , high mast light 150 watt cromton , aaliuminium ladder 15 ft , aaliuminium ladder 20 ft , main switch 63amp ( ashoka ) , main switch 32amp ( ashoka ) , solar light complete , timer , time switch repairing , contractor reparing , kit kat...

Rural Development Department - Maharashtra

37383130 supply of electrical material supply at g.p. vihirgaon , electrical items : , 6 amp switch modular anchor , 6 amp socket modular anchor , 16 amp switch modular anchor , 16 amp socket modular anchor , 12 mod plate modular anchor , 8 mod plate modular anchor , 6 mod plate modular anchor , complete led street light fitting 25 wat crompton , complete led street light fitting 30 wat crompton , complete led street light fitting 45 wat crompton , complete led street light fitting 60 wat crompton , complete led street light fitting 25 wat anchor , complete led street light fitting 45 wat anchor , complete led street light fitting 30 wat philips , complete led street light fitting 45 wat philips , complete led street light fitting 60 wat philips , complete led street light fitting 36 wat syska with day night sensor , complete led street light fitting 45 wat syska with day night sensor , complete led street light fitting 30 wat havells , complete led street light fitting 45 wat havells , complete led street light fitting 60 wat havells , complete led street light fitting 85 wat havells , complete led street light fitting 100 wat havells , cfl holder , cfl bracket pipe , cfl fitting 85 wt br & k2k , cfl fitting 36 wt br & k2k , clamp cement pole , clamp iron pole , tep roll steel grip , wire bundle( 1/18 aluminium ) i.s.i., jhonson , wire bundle( 1.00 copper jhonson ) , wire bundle( 1.50 copper jhonson ) , wire bundle( 2.50 copper jhonson ) , wire bundle( 3.20 copper jhonson ) , service wire i.s.i., national , service wire 4 mm (2 core) national , service wire 6 mm (2 core) national , service wire 8 mm (2 core) national , service wire 10 mm (2 core) national , service wire 10 mm (4 core) national , led bulb 20 watt crompton/orient/bajaj , led bulb 25 watt crompton/orient/bajaj , led bulb 30 watt crompton/orient/bajaj , led bulb 40 watt crompton/orient/bajaj , led bulb 50 watt crompton/orient/bajaj , led street light 90 watt crompton/orient/bajaj , led choke 30 watt , led choke 36 watt , led choke 50 watt , led choke 60 watt , led plate 30 watt , led plate 36 watt , led plate 50 watt , led plate 60 watt , contractor 70 ap 3 phase lnt , contractor 100 ap 3 phase lnt , armoured cable 35 sq mm24 core isi mark , armoured cable 25 sq mm24 core isi mark , armoured cable 10 sq mm24 core isi mark , armoured cable 16 sq mm24 core isi mark , high mast light 100 watt cromton , high mast light 150 watt cromton , aaliuminium ladder 15 ft , aaliuminium ladder 20 ft , main switch 63amp ( ashoka ) , main switch 32amp ( ashoka ) , solar light complete , timer , time switch repairing , contractor reparing , kit kat...

Rural Development Department - Maharashtra

37334780 supplying electrical materials and repair maintenance services at. grampanchayat somatane., tal. maval, dist. pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Rural Development Department - Maharashtra

37318891 supplying electrical materials and repair maintenance services at. grampanchayat nighoje tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Directorate Of Municipal Administration - Maharashtra

37301318 supply of electrical material at akot municipal council 2 copper wire 1.5 sq mm multistrand 3 copper wire 2.5 sq mm multistrand 4 modular swiitch 6 / 10a 5 ceiling fan 1200 mm 6 tape bundle box 7 modular switch box 12 modulecomplete 8 electronic step regulator 9 led sq / circular 16 20 watt 10 led indoor tube light fixture complete 11 mccb 500v 90 to 150 amp 12 driver 45 watt 13 kitkat 63 amp 14 copper wire 3*20 15 aluminium wire 1 / 18 16 wall fan 17 indoor led bulb 18 / 20 watt 18 led driver 48 watt 19 tc wire 2*4 sq.mm 20 ic mainswitch double pole 250 amp 63 amp 1 phasewith h.c type fuse 21 on load change over switch 16a , 415 / 500 v 3 phase 22 on load change over switch 63a , 415 / 500 v 3 phase 23 power contractor 3 pole ac 50 / 60 hz 24 short light time switch 25 cooler medium size...

Directorate Of Purchase And Stores - Maharashtra

37240632 supply, safe delivery and warranty of 400 watt hpmv ballast, rc380 25s full glow led luminaire, autonics digital time switch, 100 240vac, 50 / 60 hz, 4.2va, voltz syk 15 1 hydraulic knock out punch , supply, safe delivery and warranty of 400 watt hpmv ballast , rc380 25s full glow led luminaire , autonics digital time switch, 100 240vac, 50 / 60 hz, 4.2va , voltz syk 15 1 hydraulic knock out punch...

Rural Development Department - Maharashtra

37141993 supplying electrical materials and repair maintenance services at. grampanchayat nanekarwadi tal khed dist pune 1 supplying and erecting modulartype switch6a / 10a 2 supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia ‘b’ class g.i. pipe 1.0 m in length 3 providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete ( 20 x 25 mm stone metal ) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. ( for 8.5 to 9 m poles ) ( 16 3 2 ) 4 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness ( 4.5 + 1.75 + 1.75m ) length respectively and total 8 m long with pole cap, base plate in provided foundation. ( weight 101 kg. ) as per specification no.oh pl / stp 5 supplying and erecting street light bracket made from 25mm. dia ‘b’class g.i. pipe, 0.6m. in 6 supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 . 7 supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65. 8 supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65. 9 supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65. 10 supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65 11 supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65 12 providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis 13 labour chrages for led fitting on street light or ms light pole. 14 dismentaling charges led street light of pole. 15 1.25 mm crca sheet metal enclosures box for timmer and mcb 16 supplying pvc insulated pvc round sheathed 1.5 sq.mm 17 supplying & laying armoured cable 4c x 6 sq.mm. 18 supplying & laying armoured cable 4c x10 sq mm 19 supplying & layingarmoured cable 2c x 10 sq mm 20 supplying & layingarmoured cable 4c x 16 sq mm 21 supplying, erecting & marking spmcb 6a to 32a, b series ( for lighting ) 5 3 3 22 supplying, erecting & marking dpmcb 6 a to 32 a bseries ( for lighting ) 5 3 7 23 supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching “on” & switching “off” street light as per daily sunset and sunrise respectively 24 supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete 25 supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete… 26 supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block / provided box, with necessary materials. 4 4 3 27 supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit / trunking / inside pole. 28 supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1 4 3 29 supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 30 supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire 31 25 amp, 32 amp three phase l / t contactor 32 2.5 sq. mm multistand copper wire 33 insulation tape 34 water proof tape 35 street light pole box frp 36 cement street light pole clamp 37 m.s. street light pole clamp 38 led street light arm bend pipe 39 small size frp box for mcb 40 big size frp box for mcb 41 supplying and laying ( including excavation of suitable width & depth up to 90 cm ) 50 mm outside dia. double wall corrugated pipes ( dwc ) of hdpe for enclosing cable below ground / road surface, to required depth complete. 42 servicing and primary maintenance for street light pole. 43 light poles painting in silver colour 44 26w led light to 100w led light repairing 45 old pole shifting, rework and foundation work per pole etc. 46 supply &fixing of shakle hardware with nut bolt 47 supply and installation of mini feeder pillar with stand 48 rcc road cheasling charges with tractor breaker ( 1 hours ) 49 tree triming for overhead line 50 7 1 33 supplying, erecting & terminating xlpe armoured cable 4 core 70 sq. mm. aluminium conductor 51 7 1 31 supplying, erecting & terminating xlpe armoured cable 4 core 35 sq. mm aluminium conductor 52 7 1 34supplying, erecting & terminating xlpe armoured cable 4 core 95 sq. mm aluminium conductor 53 7 1 35 supplying, erecting & terminating xlpe armoured cable 4 core 120 sq. mm aluminium conductor 54 5 3 5 supplying, erecting & marking spmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 55 5 3 9 supplying, erecting & marking dpmcb 40a to 63a, b series ( for lighting ) in provided distribution board as per specification no. swswr / mcb 56 5 3 29supplying, fixing and commissioning mcb type change over switch 2 pole, 63 a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 57 5 3 32 supplying, fixing and commissioning mcb type change over switch 4 pole, 63a with 3 positions ( i o ii ) with centre off position as per specification no. sw swr / mcbcos 58 7 9 4 supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. cb cl / cu 59 7 9 5 supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. cb cl / cu 60 7 9 7 supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. cb cl / cu 61 4 4 5 supplying and erecting four pole power contactor 430 v, 40 a for time switch complete erected on provided wooden block / box, with necessary materials. 62 cable joint kit for armoured cable 20 upto 120sq. mm cable 63 gi tar for service wire support with bobine. 64 kit kat type fuse 16a 32a 63a 120a 65 taparia tester 66 spaner set 67 control panel hrc fuse 68 supplying and erecting transformer fidder piller 69 5 2 19 supplying & erecting street light control panel in powder coated crca 14 / 16 swg sheet, outdoor type, three phase, 415v consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, tpn mcb 63 a auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kw on provided iron frame / cc foundation. 70 bag filtter for 250 / 500 / 1000 lph ro plant 71 small cartridge filter 72 big size cartridge filter 73 coin mechanisum unit 74 aster ro atm unit 75 mech 101 ro membrane cleaning chemical liquit 5 ltr 76 sand and carban...

Rural Development Department - Maharashtra

37128996 providing led street fitting on 8 mtr pole at kolgaon , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30no x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying and erecting single phase, 240v, street light control panel up to the max load of 6kw, spn mcb 40a, powder coated crca 14 swg sheet, outdoor type, having ip54, ik10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto / manual selector switch, on / off push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation. ( 5 2 3 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying and erecting iron work, sheet metal work consisting of crca sheets, various sections of iron, plates, chequered plates, rods, bars, ms pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( 6 1 19 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no.cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting pvc insulated pvc round sheathed 1.5 sq.mm ( 30 no. x 0.25 mm dia. ) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kv ( 1 3 14 ) , supplying and erecting integrated led street light fitting 100 110w ip65 and ik08 class having single piece pressure die cast aluminium housing, having system lumens lumen / w cri>70 cct upto 6500k thd<10% pf>0.95 operating range of 140 270v inbuilt surge protection of 10kv life class of 50000 hrs. at l70b50 including driver complete with 3 years warranty as per specification no fg odf / fls2 ( 2 4 8 ) , supplying and erecting street light bracket for erection of side entry fitting on pole with 40 mm. dia. b class g.i. pipe of required length complete as per specification no. fg bkt / slb ( 2 7 9 ) , supplying, erecting and marking spmcb 6a to 32a, b series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb ( 5 3 3 ) , supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per per specification no. cb lt / al ( 7 1 5 ) , supplying and erecting g.i. pipe a class 40 mm dia. erected for enclosing xlpe armoured cable on wall / pole as per specification no. cb ce ( 7 6 2 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 , providing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.i. rod complete with all materials testing and recording the results as per specification no.o ea ep ( 9 1 4 ) , supplying and erecting frp box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb ( 7 8 8 ) , supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness ( 4.5+1.75+1.75 m ) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. ( weight 101 kg ) as per specification no. oh pl / stp ( 8 1 1 ) ...

Department of Higher Education - Maharashtra

37053430 bids are invited for cable , cable 1 , cupboard , cupboard 1 , chair , table , cable2 , connector , connector1 , regulator , switch , time switch , contactor , dp switch , cable tie , cable tie2 , socket , led lamp total quantity : 1299...

Directorate Of Municipal Administration - Maharashtra

37037704 annual maintenance contract of electrical department for indapur municipal council for year 2023 24 1 supplying & erecting mains with 2x10 sq.mmf.r copperpvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 2 supplying & erecting mains with 2x6 sq.mm f.r copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places as per specification no: wg ma / bw 3 supplying & erecting mains with 2x4 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or any other places. as per specification no: wg ma / bw 4 supplying and erecting mains with wp 2 x 6 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire. 5 supplying and erecting mains with wp 2 x 4 sq. mm. 1100 v grade aluminiumpvc insulated and pvc sheathed wires on g.i. bearer wire no. 8 swgcomplete erected with required size of porcelain reel insulators and 16 swgg.i. binding wire 6 supplyinganderectingisi mark g.i. pipepole ‘b’ grade80 mm dia 6 m longwith pole cap, base plate in provided foundation as per specification no. oh pl / gip 7 supplying and erecting rolled steel joist ( girder ) pole 125 x 70 mm ( 13.3 kg / m ) with base plate in provided foundation as per specification no. oh pl / rsj 8 supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm diawith 4.5 x 3.65 x 3.25 mm thickness ( 5+2+2 m ) length respectively and total9 m long with pole cap, base plate in provided foundation ( weight 113 kg ) as perspecification no 9 providing & erecting 7 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 130 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 10 providing & erecting 9 m high ( clear height ) galvanised octagonal pole withfoundation bolts having bottom of 155 mm a / f, top 70 mm a / f on providedfoundation as per specification no. oh pl / opl 11 providing and erecting galvanised 1000mm single arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 12 providing and erecting galvanised 1000mm double arm sword type bracket with frp domeand ball as per specification no. oh pl / pbkt 13 supplying & erecting ms pole bracket for guarding / lt oh line, fabricatedfrom angle iron 50x50x6mm and 1100mm long for necessary nos. ofprovided insulators, and erecting on pole with 50x6mm clamp complete as perspecification no. oh pl / bkt 14 supplying and erecting g.i. pipe ‘c’ class erw 25 mm dia with necessary fittings complete as per specification no. 15 supplying and erecting g.i. pipe ‘c’ class erw 50 mm dia with necessaryfittings complet 16 supplyinganderectingpole clamp madefrom50 x 6 mmms flat for pole or pipe, postcompleteerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 17 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. ea ep 18 providingpipetype earthing with 40mm. dia. g.l. pipe or 20 mm dia. g.l. rodcomplete with all materials as per specification no. ea ep 19 providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block c.l. cover complete with all materials, testing & recording the results as per 20 making cement concrete foundation including excavation ( 60 x 60 x 150 ) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, ( 45 x 45 x 45 ) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. ( above 6 m to 9 m poles ) 21 making m 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 t / sq.m at 1.5 m depth including supplyof steel, concrete, excavation and fixing provided nut bolts with the help oftemplate, duly plastered as per design complete ( for 9m & 10m high octagonal / conical gi pole ) 22 making m 20 cement concrete foundation by considering the safe soilbearing capacity at site as 10 t / sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per designcomplete ( for 12.5 m raising lowering high mast ) 23 painting of steel tubular / rail / rsj pole above 6.0 m length along withstreet light pole brackets, clamps etc by scrapping the existing paint completeas per specification no cw ptg / ptp. 24 supplying, erecting & marking dpmcb 6a to 32a, c series with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as perspecification no. sw swr / mcb 25 supplying, erecting & marking dpmcb 6 a to 32 a b series ( for lighting ) in provided distribution board as per specification no. sw swr / mcb 26 supplying and erecting porcelain base iron clad cut out hc type 415v, 63aerected on polished wooden block. 27 supplying and erecting porcelain base iron clad cut out hc type 415v, 100aerected on polished wooden block. 28 supplying and erecting porcelain base iron clad cut out hc type 415v, 200aerected on polished wooden block 29 supplying, erecting & marking tpmcb 40a to 63a, with rated short circuitbreaking capacity ( icn ) 10ka in provided distribution board as per specificationno. sw swr / mcb 30 supplying, erecting & marking fpmcb 40a to 63a, with rated short circuit breaking capacity ( icn ) 10ka in provided distribution board as per specification no. sw swr / mcb 31 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 32 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 33 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 34 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 35 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / al 36 supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured ( strip ) cable 1100 v, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification no. cb lt / cu 37 supplying & erecting d.o.l starter suitable for 415 v, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supplyup to 7.5 h.p. 38 supplying & erecting fully automatic star / delta starter suitable for 12.5 h.p to 15 h.p. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame 39 supplying & erecting frp box of size 300mm x 200mm x 125 mm, 2.7 mmthick complete on pole / wall as per specification no. cb sb 40 supplying & erecting frp box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole / wall as per specification no. cb sb 41 supplying andlaying ( including excavation of suitable width & depth up to 90 cm ) 90 mmoutside dia. double wall corrugatedpipes ( dwc ) ofhdpe for enclosing cable below ground / road surface, to required depth complete. 42 supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. cb cl / cu 43 supplying & erecting crimping type copper lugs for cable120 sq. mm. completeas per specification no. cb cl / cu 44 supplying and erecting metal work in crca sheet including iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. ( meter pannel box ) 45 point wiring for light / bell hybrid type ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing n capping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories as per specification no: wgpw / hw 46 point wiring for ceiling fan ( surface type under false ceiling and concealed type for drops & switch boards on walls ) in min 20 mm pvc conduit / casing ncapping with 1.5 sq.mm. ( 2+1e ) frlsh grade copper wires, modular type switch, earthing and required accessories 47 supplying and erecting mains with 2x2.5 sq.mm frlsh copper pvc insulated wire laid in provided conduit / trunking / inside pole / bus bars or anyother places. as per specification no: wg ma / bw 48 supplying and erecting modular type ( two module ) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 49 supplying and erecting regular / standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. fg fn / cf 50 supplying and erecting bracket fan 400 mm. sweep a. c. 230 volts 50 cycles 1350 rpm. oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘e’ class insulation 51 supplying and erecting exhaust fan medium duty 230 v a.c. 50 cycles 225mm. 1400 rpm with condenser complete erected in position with necessary materials. fan motor with moisture proof treatment and ‘e’ class insulation. 52 supplying and erecting integrated led street light fitting 23 to 25w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 2300 lumens, min. efficacy of 100 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3years warranty as per specification no fg odf / fls2. 53 supplying and erecting integrated led street light fitting 40 to 50w ip65 &ik08 class having single piece pressure die cast aluminium housing, havingsystem lumens output of min. 4400 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuilt surge protection of 10 kv, life class of 50, 000 hrs. at l70b50, includingdriver complete with 3 years warranty as per specification no fg odf / fls2. 54 supplying and erecting integrated led street light fitting 70 75w ip65 & ik08class having single piece pressure die cast aluminium housing, having systemlumens output of min. 7700 lumens, min. efficacy of 110 lumen / w, cri>70, cct upto 6500k, thd<10%, p.f. >0.95, operating range of 140 270v, inbuiltsurge protection of 10 kv, life class of 50, 000 hrs. at l70b50, including drivercomplete with 3 years warranty as per specification no fg odf / fls2. 55 supplying and erecting integrated led flood light fitting max. 70w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min. 8400 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2. 56 supplying and erecting integrated led flood light fitting max. 120w ip65 &ik07 class having pressure die cast aluminium housing, having system lumensoutput of min.14500 lumens, min. efficacy of 120 lumen / w, cri>70, cctupto 6500k, thd<10%, p.f. >0.90, operating range of 140 270v, inbuilt surgeprotection of 4 kv, life class of 50, 000 hrs. at l70b50, including driver with ushaped bracket with 3 years warranty as per specification no fg odf / fls2 57 erecting departmentally supplied led street light / flood light fitting above80 to 150w . 58 supplying and erecting street light bracket made from 40 mm. dia ‘b’ classg.i. pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm diaduly welded with provided leads as per specification no. fg bkt / bpc 59 supplying and erecting electronic type driver for outdoor led fittings 46w 75w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 60 supplying and erecting electronic type driver for outdoor led fittings 151w 200w suitable to operate on 230v a.c. 50 hz. having pf>0.95 and thd<10%. 61 supplying and erecting t8 fluorescent tube day light 600mm, 18 w 62 supplying & erecting ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete &compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary. 63 supplying and erecting flush type shockproof plug socket 6a & 16a ( 6 pin ) with 16a switch combined with indicator lamp and fuse with gang box onwooden board 64 supplying and erecting modular type 32a, dp key tag switch with key tag, duly erected on provided plate and box with wiring connections complete 65 supplying & erecting 18w, 230v integral type led lamp suitable for b 22 / e 27 base 66 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 700va digital pure sine wave inverter with backup time of ........ hrs. based oninsulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 67 supplying, installing, testing and commissioning of single phase, 230v, 50 hz, 1400 to 1600va digital pure sine wave inverter with backup time of ........ hrs.based on insulated gate bipolar transistor ( igbt ) technology complete as perspecification no. ap inv 68 supplying, erecting, testing and commissioning of single phase input & 1 phaseoutput 1 kva capacity online pure sine wave ups, with backup time of .......hrs. pwm & igbt based, with 0.8 to unity output pf complete with allprotections as per specification no. ap ups 69 supplying and erecting 12v / 200ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 70 supplying and erecting 12v / 150ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 71 providing servicing of 1 / 1.5 / 2 / 3 tr capacity split / window airconditioning unit with all necessary material. job includes checking ofperformance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to engineer incharge. 72 providing annual comprehensive maintenance contract for 1.5trsplit / window air conditioning unit complete as per terms and conditions. jobincludes 1 ) quarterly servicing 2 ) on call repair 3 ) replacement of all spares within24 hours 4 ) sending standby manpower for vip movement. the job exclude sheetmetal work and plastic material 73 providing brazing pipes and checking leakages in the split / window unitduly with dry nitrogen pressure, complete. 74 providing replacement of unserviceable pcb for ac unit upto 3tr capacity 75 supplying and erecting quartz electronic time switch having 24 hour dial towork on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteriesto run the time switch on failure of supply having switch contact rating up to 16ato use independently or in conjunction with contactor 76 supplying and erecting four pole power contactor 430 v, 40 a for time switchcomplete erected on provided wooden block / box, with necessary materials 77 supplying and erecting programmable digital almanac timer microcontrollerbased with real time clock to operate on derived switching “on” and switching“off” street light as per daily sunset and sunrise respectively automaticallyhaving 4 digit led continuous time display, relay output 230 v / 10a with 10hrs. battery backup and manual over drive facility capable to drive differentcapacity contactors timer erected in provided m.s. box 78 supplying and erecting static energy meter with 240v 50 hz. ac supply 10to 60 a, isi mark, accuracy class 1.0 with backlit lcd display, ( measuring anddisplay kwh, kvah, v, i, pf, frequency, kw, kva, six months history ofenergy & md in kw & kva ) with transparent hinge type box completeerected on polished teak wood board duly wired with required size ofweather proof pvc wires duly tested by electric supply company 79 supplying & erecting crimping type aluminium lugs for cable 240 sq mmcomplete as per specification no. cb cl / al 80 supplying and erecting all aluminium stranded conductors 7 / 2.21 mm.complete. ( gnat ) ( 73.77kg / km ) as per specification no. oh con / aac 81 supplying and erecting 3 phase 4 core 35 sq.mm. ( 3x35+1x25 ) aerial bunchedaluminium cable along with necessary accessories for lt distribution onprovided lt pole as per specification no. oh cbl / abc 82 supplying and erecting g.i. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, g.l. staywire 7 / 10 swg, g.l. stay rod 20mmx1.8m length and pole clamps duly erected inprovided cement concrete foundation complete 83 dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level. 84 supplying and erecting of isi mark insulation tape 85 supplying and erecting of isi mark nutbolts 86 supplying and erecting of isi mark tester 87 supplying and erecting of isi mark led zero bulb 88 supplying and erecting of isi mark led zero bulb holder 89 supplying and erecting fault clearing on street light conductor 90 supplying and erecting of ac servicing 91 supplying and erecting of filter servicing 92 supplying and erecting of batery servicing with water change 93 supplying and erecting of ro membrane for filter 94 supplying and erecting isi mark extension box...