Brihan Mumbai Mahanagarpalika - Maharashtra
37881564 supply, installation, testing and upgrade of pen stock gates electric equator, 11 kv ht vcb panel work...
37881564 supply, installation, testing and upgrade of pen stock gates electric equator, 11 kv ht vcb panel work...
37875239 tender for supply, installation, testing &commissioning of 630 kva transformer and11 kv ht vcb panels along with allied works at sant gadge maharaj chowk pumping station...
37486907 tender for design, manufacture, procure, supply, structure, erection and commissioning of 2000 kw ht slip ring motor with asr, vcb panel, capacitor and ht cable with panel...
37467051 replacement of vcb sprouts of 11kv abb make vcb panels of main hill substation of chikla mine => limited...
37049281 supply of set of spare for filter for dj/vcbset of spare for filter for dj/vcb,set of spare for filter for dj/vcb panel of siemag make model no.sb.ss.60.sh4 one set comprising of 7 items = 07 nos. as per drg.no. bsl/elw/sk no.9098. [ warranty period: 30 months after the date of delivery ]...
36960941 bids are invited for i ) supply, installation, testing and commissioning of 2 nos of indoor type 11kv, 800 a vcb panel with current transformers and metering for tapping power to hip substation ii ) supply, installation, testing and commissioning of 5 nos of indoor type 11 kv, 800 a vcb panel with current transformers, potential transformers and metering to receive power to hip substation supply, installation, testing and commissioning of 2 nos of outdoor type 2500 kva, 11 kv, / 433 v, onan transformer with oltc, rtcc, avr etc iv ) supply, laying, testing and commissioning of ht 11 kv cable and ht 11 kv straight through and end termination joints etc v ) supply, installation, testing and commissioning of 415 v lt main power panels, lighting panel in substation. vi ) supply, installation, testing and commissioning of 415 v automatic power factor correction panel ( apfc ) of rating 1250 kvar in substation. vii ) supply, laying, testing and commissioning of lt power & control cables, terminations of cables etc viii ) supply, installation, testing and commissioning of safe earth electrode earthing system ( gi coated and copper coated ) and earthing strips. ix ) supply, installation, testing and commissioning of diesel generator set of rating 25 kva 3 phase, 415 volts, 50 hz complete with automatic mains failure ( amf ) panel for staring on mains failure with meters and sound proof canopy as per cpcb norms, with foundation and other associated civil works complete. supply, laying, testing and commissioning of battery charger panel and battery. xi ) obtaining approval for charging of the substation from central electricity authority ( cea ) ...
36434142 bids are invited for procurement of vcb panels a panel of 6 vcbs, 11kv, 150mva , 400a, nflp indoor type distribution board panel , a panel of 6 vcbs, 11kv, 150mva , 400a, nflp indoor type distribution board panel , a panel of 13 vcbs, 3.3kv, 75mva , 1250a, nflp indoor type switch board panel , a panel of 14 vcbs, 11kv, 75mva , 1250a, nflp indoor type switch board panel , a panel of 6 vcbs, 3.3kv, 75mva, 1250a, nflp indoor type switch board panel , a panel of 19 vcbs, 3.3kv, 75mva, 400a, flp indoor type switch board panel , a panel of 3 vcbs, 3.3kv, 75mva, 400a, nflp indoor type switch board panel , a panel of 3 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board , a panel of 4 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board , a panel of 5 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board total quantity : 13...
35883464 work of repairing, servicing ,testing of 11kv vcb panels at wadala pumping stations...
35743293 manufacturer of vcb panel /switchgear, wireless temperature sensors....
35666735 replacing of existing old ht bocb panel with ht vcb panel 11kv 630 amps rmu extensible type outdoor/ indoor scada compatible motorized unit in substation and other allied works at nehru science centre mumbai...
35628583 tender for special repair to 22 kv main icog vcb panel with connected accessories and provisioning of cabling and associated fitting and panels for stand by power supply augmentation to inhs kasturi at ins shivaji lonavla...
35574804 supply, installation and commissioning of 11 kv vcb panels, transformers, 11 kv cable, lt panels and other electrical accessories for the hot isostatic press ( hip ) facilities at hal, nasik...
35549703 tender for repair maintenance to ht equipments for shore supply at various cassions and jetties at naval dockyard under ge nw kunjali colaba mumbai supplying , laying, jointing testing and commissioning of ht ug cable, xlpe insulated, screened insulated, armoured and pvc bedded, 11000 volts grade ( heavy duty ) suitable for earthed system with aluminium conductor of size 3 core 240 sq.mm conforming to is 7098 part ii laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cable complete all as specified and directed by engineer in charge. 2 supplying , laying, jointing testing and commissioning of ht ug cable, xlpe insulated, screened insulated, armoured and pvc bedded, 11000 volts grade ( heavy duty ) suitable for earthed system with aluminium conductor of size 3 core 185 sq.mm conforming to is 7098 part ii laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cablecomplete all as specified and directed by engineer in charge . 3 material and labour cable end termination box, heat shrinkable, indoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any description complete all as specified and directed by engineer in charge. 4 material and labour cable end termination box, heat shrinkable, indoor type suitable for 6.6 11kv, 120 to 185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any description complete all as specified and directed by engineer in charge. 5 material and labour cable end termination box, heat shrinkable, outdoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 6 material and labour cable end termination box, heat shrinkable, outdoor type suitable for 6.6 11kv, 120 to 185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 7 material and labour straight through joint , heat shrinkable, outdoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 8 material and labour straight through joint , heat shrinkable, outdoor type suitable for 6.6 11kv, 120 to185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 9 note for item no. 1 to 8: above quoted rates deemed to be included for fault finding manually or by machine and repairing it within 12 hrs. 10 material and labour for ( i ) disconnecting the ht / lt side and earthing connections of the transformer, ( ii ) lifting transformer with the help of crane, loading on suitable vehicle to transport it to the workshop and unloading at workshop for servicing ( iii ) dismantling of hv / lv bushing, opening of top cover, disconnecting of connections of tap changer of transformer ( iv ) draining out the complete transformer oil ( v ) lifting up the core and winding assembly ( vi ) washing and cleaning the core, rewinding of all burnout, damaged coils of core and phase, transformer tank and radiator fins with help of pressurized transformer oil for removal of sludge and sludge deposit so as to make them free from dust, dirt and sludge deposit ( vi ) heating and ovening of core and winding assembly complete in vacuum chamber for 72 hours so as to remove any moisture content in the core / winding and attaining requisiteir value, ( vii ) retanking of complete core & winding assembly & fixing tap changer after servicing and testing, ( viii ) refixing hv / lv bushing and making all internal connections, ( ix ) providing new gasket packing minimum 12mm thick, including nut bolt washer complete, ( x ) transporting transformer back to the site , lifting it down with the help of crane and reconnectingthe ht / lt cable and earthing connections complete all as specified and directed by engineer in charge. of followings capacities: 11 500 to 630 kva, 6.6 11kv / 433v 12 631 to 1000kva, 6.6 11kv / 433v 13 1001 to 1600kva, 6.6 11kv / 433v 14 1601 to 2500kva, 6.6 11kv / 433v 15 note for item no 9.00 : ( i ) in case of damage during transport / loading / unloading at any stage after receipt of transformer from department, the contracor shall be repsonsible for damage and it shall be made good by him at his for expense.the decision of engineer in charge in the regards shall be fixed & binding ( ii ) transformer oil required for filling shall be measured and paid seperately ( iii ) all other spares required shall be measured and paid sperately ( iv ) rates are inclusive of testing of earthing before connection of transformer 16 material and labour for shifting transformer upto 2500 kva, 6.6 11kv / 433v, from location inside dockyardand connecting ht / lt side to provide temporary supply during repair of transformer and disconnectinght / lt connections before installations of repaired transformer location within naval dockyard complete all as specified and directed by engineer in charge. 17 material and labour in repairs hv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for 500 to 1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step up of any make / model complete all as specified and directed by engineer in charge. 18 material and labour in repairs hv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for above1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step upof any make / model complete all as directed 19 material and labour in repairs lv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for 500 to 1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step up, of any make / model complete all as specified and directed by engineer in charge. 20 material and labourin repairs lv side brass studs threaded both ends of suitable size and length including metal and rubber rings, bolts washer, etc. suitable for above1600 kva to 2500 kva transformer and above outdoor type, 6.6 11kv / 433v step down / step up ) of any make / model complete all as specified and directed by engineer in charge. 21 supply and fixing in repairs hv / lv side porcelain bushing / insulator of suitable size suitable upto2500kva transformer, outdoor type, 6.6 11kv / 433v , step down / step up, of any make / model complete all as specified and directed by engineer in charge. 22 supply and fixing in repairs hv / lv side porcelain bushing / insulator of suitable size suitable for above 500kva transformer, outdoor type, 6.6 11kv / 433v , step down / step up, of any make / model complete all as specified and directed by engineer in charge. 23 supply and fixing in repairs silica gel container with first fill of silica gel transparent type suitable for transformer of capacity 500 kva to 1250 kva complete all as specified and directed by engineer in charge. 24 supply and fixing in repairs silica gel container with first fill of silica gel transparent type suitable for transformer of capacity above 1250 kva to 2500 kva complete all as specified and directed by engineer in charge. 25 testing of di electric strength of transformer oil of transformer indoor / outdoor type, 6.6kv / 433 volts, before filteration and to remove moisture and impurities and to improve di electric strength above 48 kv / minute through filtration plant incl filling of new transformer oil for topping up, testing complete all as specified and directed by engineer in charge. filtration of transformer oil by electrically operated transformer oil filtration plant to achieve a test result of 48 kv / min for distribution transformer and 80 kv / minute for power transformer for 2.5 mm gap. ( note: testing machine and transformer oil filtration plant as well as dehydration facility will be provided by the contractor .ii ) new transformer oil shall be measured and paid separatelly under respective items ) . 26 supply only transformer oil as per is 335 / 93 dehydrated to give bdv value not less than 50 kv when tested with 2.5mm gap electrode complete all as specified and directed by engineer in charge. 27 supply only silica gel in air tight container suitable for dehydrating breathers of transformers complete all as specified and directed by engineer in charge. 28 material and labour for replacement of the following for 500 kva to 2500 kva, 6.6 / 6.6 11kv / 433v transformer: 29 oil level indicator 30 tap changer 31 dial type 100mm dia oil temp meter 32 air release plug assembly 33 drain plug 34 gun metal oil drain valve 25mm / 40mm 35 material and labour for spraying painting to indoor / outdoor type, step up / step down / step up transformer 6.6 / 6.6 11kv / 433 v installed at different locations of nd area after scraping thoroughly the existing corroded paint / rust, filling of cavities and applying one coat of silicon acrylic heat resistant paint of approved quality of approved colour and writing the details such as, sm / mes no. etc. complete all as specified and directed by engineer in charge for following capacity. 36 500to 630 kva 37 631 to 1000kva 38 1001 to1600kva 39 1601 to2500kva 40 material and labour for pcc 1:4:8 type d2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified and directed by engineer in charge. 41 material and labour for pcc 1:3:6 type c2 using 40 mm graded aggregate in foundation, filling and mass concrete complete all as specified and directed by engineer in charge. 42 supply and fixing acb 2500a, edo type 4 pole , retrofit type , designed as per exisitng lt panel complete all as specified and directed by engineer in charge. 43 material and labour of the pvc board of appropriate size and thickness duly pasted with computerised letter mentioning no smoking , danger 11000 volts with skull and cross painted, no admission except on duty, sm / mes no. for the transformer / ht breakers / dg setsincluding accessories etcfor the substations including accessories for properly fixing the same on wall / fencing / pole complete all as specified and directed by engineer in charge. 44 material and labour trench / duct cover, light weight, anti corrosive, with frp pultruded section to meet specific load application of cable pit covering complete all as specified and directed by engineer in charge. 45 material and labour for fixing standard shock treatment chart in english & hindi duly framed and covered with glass complete all as specified and directed by engineer in charge. 46 supply , fixing, testing in repairsof jef eco safe maintenance free grounding solution set comprising of high tensile low carbon steel rod of 3 mts length & 25 mm dia with 250 micron ( averaschneider ) molecularly bonded copper on the outer surface to confirm with requirements of ul467 along with back fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 ohm mtr as per clause 14.5d of ieee : 80 standard. back fill compound should be electronically conductive ( like in metals ) and should not depend on moisture for conduction. jef powerfill loresco compound shall be supplied in 50 pound bag. ( 1 bag of 50 pounds required per earthing set ) . back fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. a suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl complete all as specified and directed by engineer in charge.note : back fill compound shall not be mixed with any soil while pouring in the bore hole. 47 supply fixing, testing in repairs of jef eco safe maintenance free grounding solution set comprising of high tensile low carbon steel rod of 3 mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of ul467 along with back fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 ohm mtr as per clause 14.5d of ieee : 80 standard. back fill compound should be electronically conductive ( like in metals ) and should not depend on moisture for conduction. jef eco safe compound shall be supplied in 50 pound bag. ( 1 bag required per earthing set ) . back fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. a suitable earth terminaton clamp should also be suppliednote : back fill compound shall not be mixed with any soil while pouring in the bore hole. 48 supply and fixing for repair of earth continuity conductor or main earthing lead of following size of galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduct / pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and directed by engineer in charge. 49 32x6mm 50 25x4mm 51 material and labour for preparation of oldsurfaces of transformer foundation and applying two coat of cement based paint on it, all as specified and as directed by engineer in charge 52 supply and fixing in repairs 6.6 11 kv single phase current transformer ( cts ) conforming to is 2075, va burden 1va, class of accuracy 0.5 / 5p 10 / ps, type of ct as per existing with ctr 40 20 / 5a / 5a / 100 50 / 5a / 5a complete all as specified and directed by engineer in charge. 53 material and labour for test point terminal block made out of gun metal or phosphorus bronze size 75 x 25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws to be fixed on steel structure with drilling / tappingandclamping etc complete all as specified and directed by engineer in charge. 54 material and labour galvanised pipe including fittings, light grade fixed to poles, on walls laid under road in trenches for protection of underground cable complete all as specified and directed by engineer in charge of 100mm dia. 55 provision of cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with the existing surfaces with pcc 1:3:6 type c2, complete all as specified and as directed by engineer in charge. 56 supply and fixing insulation mat as per is15652:2006, having not less than 30kv dielectric strength and having insulation resistance of not less than 1mohm, acid retardant, flame retardant with auto glow band, having width of 1.0mtr and length upto 2.0 mtr, of thickness not less than 2.50 mm.complete all as specified and directed by engineer in charge. 57 supply and fixing in repairled lamps of existing lt panel board and supply and fixing new led lamp including making necessary electrical connection all as specified and directed by engineer in charge. 58 supply and fixing cost effective, durable and reliable 6.6 11 kv heat shrinkable anti tracking bus bar tubing sleeve of dia 50mm, for bus bar of vcbs, flame retardant and protetcion againstmoisture, dust including all accessories complete all as specified and directed by engineer in charge.of make jointmask 1133 series. 59 supply and fixing in repairs 11 / 6.6 kv potenialtransformer ( pts ) as per existing size and make suitable for ht vcb panel of incuding taking down old unserviceable ptscomplete all as specified and directed by engineer in charge. 60 supply and fixing in repairs 11 / 6.6 kv spout as incomer [ ryb ] one set and outgoing [ ryb ] oneset as per existing size and make suitable for ht vcb panel incuding taking down old unserviceable spout set complete all as specified and directed by engineer in charge....
35292756 supply installation and commissioning of vcb panel at hariyala lpg plant...
35170964 repairing of sub station equipment at t.e building kandivali mtnl mumbai. as per nit repairing of faulty 11 kv vcb including dismantle vacuum interrupters, mounting supports & insulators. cleaning carbon from all parts, testing ir value of insulators. vacuum interrupters & supports including. apply high voltage test. reinstalling vacuum interrupter and mounting supports, insulator, testing ir value & on / off operation, electrical and mechanical spring charging system repair, including repairing and calibration of mechanical spring charging gearbox, repair of 2 nos frp supporter set, repairing of 2 nos frp spring set, repairing of 2 nos supporter insulator megraing, including loading / unloading & transportation to work shop if required complete as required. 1 job 2 repairing of vacuum interrupter in 11 kv vcb panel i / c testing, meggering complete as required. 3 job 3 repairing, servicing & lubrication of acb of all ratings i / c all components, repair mechanism system etc complete as required. 1 job 4 sitc of following rating fn type tpn sfu with operating handle in the existing above panel i / c interconnection etc. complete as reqd. a ) 100 amp 1 no 5 servicing / checking and removing of oil leakage in 1250 kva oil type transformer i / c disconnection of ht and lt side cable & bus bar, remove complete oil and store in drum, and lift transformer if required with the help of chain pulley, specialized labour, i / c changing transformer gasket and transformer body butterfly radiator leakage attend, oil remove and oil top up, reconnection ht and lt side etc complete as required....
34381194 bids are invited for supply, installation, testing and commissioning of 11kv, 800a vcb panel (incomer cum outgoing) as pe(q3) total quantity : 2...
33885667 repair / maintenance of high tension distribution system and ht equipments at kanheri hills and hill top at site k hills site r and site p under ge airforce thane m&l for calibration all measuring meter with, servecing all mechanical parts, replace the all electric wiring of panel, decarbonizing all ht contact point testinght 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampsincluding replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmete , vaf meter, selector switch all illuminated indicationes for r, y, b, pahse, by qualified technical person from oem, complete all as specified and directed by engr in charge.note: necessary spare parts, need to replace will be paid in respective item. 2 m&l for calibration all measuring meter with, servicing all mechanical parts, replace the all electric wiring of panel, decarburizing all ht contact point testinght 11kv vertical draw out type vcb of rupturing capacity 250 mva, 250 ampsincluding replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vacuum of interrupter, including connected accessories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmeter , vaf meter, selector switch all illuminated indications for r y b phase, including high voltage test, primary injection test, relay testingby qualified technical person from oem, complete all as specified and directed by engr in charge.note: ( a ) necessary spare parts, need to replace will be paid in respective item ) 3 m&l for indicator led lamp, red, yellow and orange 110 v, ac, for ht 22 kv vcbcomplete all as specified and directed by engr in charge. 4 supply closing coil, 110 v, dc for servicing / repairing the ht 22 kv vcb complete all as specified and directed by engr in charge. 5 supply shunt release coil on, 110 v, dc, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 6 supply shunt release off, 110 v , dc, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 7 supplycontrol fuse, hrc, 2 / 4 / 6 amp for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 8 supply motor cut off switch for servicing / repairing the ht 22 kv vcbcomplete all as specified and as directed by the engr in charge. 9 supply ht tape for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 10 supplymonoplast tape for servicing / repairing the ht 22 kv vcbcomplete all as specified and as directed by the engr in charge 11 supply digital volt meter 96x96mm, 0 500v, aux supply 110v, ac, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 12 supply digital ammetersuitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 13 supply auxiliary switch on block magnet for servicing / repairing the ht 22kv vcb complete all as specified and as directed by the engr in charge. 14 supply male & female spout assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 15 supplyct of ratio 50 / 5 a for vcb suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 16 supplyover current really suitablefor servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 17 supply master trip relay suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 18 supply digital vaf meter , em 6400suitable for ht 22 kv vcb for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 19 supply contact arm assembly for ht 22 kv vcb for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 20 supply closing coil, 110v, dc for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 21 supply shunt release on, 110v, dc for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 22 supply shunt release off, 110v, dcfor servecing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 23 supply motor cut off switch for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 24 supply auxiliary switch on block magnetfor servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 25 supply male & female spout assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 26 supply ct of ratio 30 / 5 a for vcbfor servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 27 supply relay assembly ( current, voltage ) suitable for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 28 supply master trip relay suitable for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 29 supply contact arm assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 30 m&l forservicing / testingofpower transformer11 / 22 / 0.44 kv up to capacity 400kva ( a ) ir value of winding. ( b ) de carbonizing the cable terminal of the transformer. ( c ) earth resistance checking. ( d ) replacement of silica gel 31 dehydration / filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 35 to 40 kv at 2.5 mm gap in existing position of transformer / servo stabilizer of any capacity and transformer oil for topping up at various sub station complete all as specifiedand directed by engg in chargenote: transformer oil used for top up measured and paid separately. 32 supply and pouringof new transformer oil to achieve a di electric strength up to 60 kv in 4 mm gap conform to is 335 1983 with sealed barrel contains each 210 litre 33 disconnection the ht termination, supply and fixing ht boot cover at cable end and vcb / rmu complete all as specifiedand directed by engg in charge 34 disconnecting all in coming and outgoing cables, removing the transformer / servo stabilizer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractors workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable sizetaping thebushes / bus bars, using insulation tape and testing completeof capacity 160 kva to 400 kva all as directed .note: gasket set, lt / ht side ceramic bushing, spindle for ht / lt side , rewinding, dehydration of oil shall be measured and paid separately in respective items. 35 m&l for taking out unserviceable winding & supply and winding of22 / 0.433 kv hv coils, using new copper wire / strip of proper size including insulating materials ( double insulation ) as per existingsize of core of transformer capacity 160 400 kva complete including heating , varnishing complete all as specifiedand directed by engg in charge 36 m&l for taking out unserviceable winding supply and winding of22 / 0.433 kv lv coils, using new copper wire / strip of proper size including insulating materials ( double insulation ) as per existingsize of core of transformer complete incl heating , varnishing complete all as specifiedand directed by engg in charge 37 supply only breather assembly of approved make filled with silica gel suitable for transformer ofcapacityupto 400 kva volt distribution transformer complete all as specifiedand directed by engg in charge 38 supply only brass spindle for terminal on ht side threaded complete with nut washers etc of suitable dia for transformer of capacity 160 to 400 kva complete all as specifiedand directed by engg in charge 39 supply only brass spindle for terminal on lt side threaded complete with nut, washers etc of suitable dia for transformer ofcapaicty 160 to 400 kva complete all as specifiedand directed by engg in charge 40 supply and fix ceramic bushing and gasket on lt side of transformer of capacity 160 to 400 kva 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 41 s & fceramic hv bushing with gun metal bushing stud, nuts and washers for transformerof capacities 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 42 supply and fixing in replacement of complete gasket ( cork sheet ) 6 mm thick complete of capacity of 160 kva to 250 kvatransformer including conical rubber bush complete all as specifiedand directed by engg in charge 43 disconnecting all incoming and outgoingconnection of ht11 / 22 kv underground cable, detecting faultby applying surge current 1.5 times the rated current& finding exact location of fault with picco equipmentand repair the same immediately all as directed. note: ( a ) necessary jointing kit to be measure and paid cables. complete all as specifiedand directed by engg in charge 44 supplying, jointing and commissioningoutdoor type cable end termination jointing kit heat shrinkable type suitable for underground xlpe cable size 3 core 95 to 120 sqmm 11 / 22 kv ht cablecomplete all as specifiedand directed by engg in charge 45 supplying, jointing and commissioningindoor type cable end termination jointing kit heat shrinkable type suitable for under ground xlpe cable size 3 core 95 to 120 sqmm 11 / 22 kv ht cable complete all as specifiedand directed by engg in charge 46 supplying, jointing and commissioningstraight through type cable end termination jointing kit heat shrinkable type suitable for underground xlpe cable size 3 core 95 sqmm 11 / 22 kv ht cable complete all as specifiedand directed by engg in charge . 47 taking up unserviceable ht 22 kv underground cable for repair, replace the damage portion complete all as specifiedand directed by engg in charge 48 supply and laying, testing and commissioningh.t. under ground armored pvc insulated and pvc sheathed heavy duty 22000 volts grade underground cable of size 3 core, 95 sq mm complete all as specifiedand directed by engg in charge 49 supply and laying, testing and commissioningh.t. under ground armored pvc insulated and pvc sheathed heavy duty 11000 volts grade underground cable of size 3 core, 120 sq mm complete all as specifiedand directed by engg in charge 50 relaying the serviceable ht cable, after necessary testing in ground, floor in same trench ornew route complete all as specifiedand directed by engg in charge 51 supply and fix gi pipe 100 mm dia light grade complete with all fitting for supporting cable on four pole structure complete all as specifiedand directed by engg in charge 52 excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out / laying cable and getting out in hard / dense soil complete all as specifiedand directed by engg in charge 53 removing excavation soil at a distance not exc 50 m and deposited where diverted complete all as specifiedand directed by engg in charge 54 returning, filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as specifiedand directed by engg in charge 55 sand cushioningfor cable protection by spreading in trenches crushed stone sand by gently punning down manually complete all as specifiedand directed by engg in charge.note: punnned thickness shall only be measured and paid. 56 supply and laying un reinforced precast concrete cable cover class ehv, type i, flat size 300 mmx 180 mm x 40 mm laid in trenches complete all as specifiedand directed by engg in charge. 57 re laying un reinforced precast concrete cable cover class ht, type i, flat size 300 mmx 180 mm x 40 mm laid in trenches complete all as specifiedand directed by engg in charge. 58 supply and cross arm, bracing, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding, bending, drillingholes for bolts in any shape and any size inclusive of one primer coat, two coats of aluminium paints as indicateed complete all as specified and as directed by engineer in charge 59 dismelting the unserviceable broken gi strip of any size as available at site, supply and fixing cupper strip of size 32x6mm for connection from ht equiptment to earth pit . ( necessery connection to be made through brezing and brass nuts and bolt ) complete all as specifiedand directed by engg in charge 60 m&l for shutter assembly suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 ampscomplete with mechanism complete all as specifiedand directed by engg in charge 61 m&l for pt 22 kv / 110vsuitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps for metering purpose complete all as specifiedand directed by engg in charge 62 m&l for breaker bus bar arm long with female contact suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps complete all as specifiedand directed by engg in charge 63 m&l for pp tubes suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps along with necessary accessories complete all as specifiedand directed by engg in charge 64 m&l for phase barrier along with necessary accessories suitable for ht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps complete all as specifiedand directed by engg in charge 65 m&l for heater and thermostat suitable for ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 66 m&l for bushing spout panel ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 67 m&l for tnc switch suitable for ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 68 s&f in replacement single phase smps based battery backed power pack for supply back up for trip coil, protection relay, indication, & other load in ht panels, working input voltage 90 to 300 volt ac, output 110 volts dc with backup for 15 20 min, complete all as specifiedand directed by engg in charge 69 m&l for painting of transformer foundation with two coats of obd after complete scrapping of old paint / whitewash and making good surface complete all as specifiedand directed by engg in charge 70 m&l for ht 22 kv sleeve for repairing vcb 22 kv complete all as specifiedand directed by engg in charge 71 m&l for end terminal cable jointing kit for 22 kv ( earthed ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specifiedand directed by engg in charge 72 m&l for end terminal cable jointing kit for 22 kv ( earthed ) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specifiedand directed by engg in charge 73 m&l for cable jointing kit for 22 kv ( earthed ) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. 74 dehydration and filtration of transformer oil filled in transformer installed at different locations, testing of oil after dehydration to achieve dielectric strength not less than 40 kv for 1 minute in 2.5 mm electrode gap as per relevant is and to bring the acidity with the permissible limit complete all as specifiedand directed by engg in charge 75 supply & fixing in replacement of ceramic hv bushing with gun metal bushing stud, nuts and washers for transformerof capacities 165 / 250 kva complete all as specifiedand directed by engg in charge 76 supply & fixing in replacement of ceramic lv bushing with bushing stud ( brass metal ) , nuts and washers for transformerofcapacities 165 / 250 kva complete all as specifiedand directed by engg in charge 77 supply and filling fresh tansformer oil confiming to is 335 having die electric strenght up to 50 kv with oil testing kit 2 mm thick top up transformercomplete all as specified and as directed by engr in charge. 78 disconnecting of incoming & outgoing cable from both side of transformer indoor / outdoor type including all accessories, loading unloading and transportation from site to work shop as per site requirement and back to site after carried out repairs & assembling , including connection for the capacity 160 kva to 250 kva and commissioning and testing complete all as specified and directed by engr in charge.note: gasket set, lt / ht side ceramic bushing, spindle for ht / lt side, rewinding , dehydration of oil shall be measured and paid separately in respective items. 79 taking out defective ht winding and m& l for rewinding of ht coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 kva complete all as specified and directed by engr in charge. 80 m& l for rewinding of lt coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 kva complete all as specified and directed by engr in charge. 81 assembling of hv and lv coils including necessaryinsulation with paperboards and varnishing, making internal connections, drying, removal of moisture from core and coils, heating the complete and carried out all necessary tests for transformer capacity 160 kva to 250 kva complete all as specified and directed by engr in charge. 82 m& l for improvement of insulation resistance value for core & coil winding by cleaning complete, applying varnishing & necessary insulation material and baking in oven terminal connection inside the transformer complete all as specified and directed by engr in charge. 83 disconnecting the ht termination, supply and fixing ht boot cover at cable end and vcb complete all as specifiedand directed by engg in charge 84 disconnecting all incoming and outgoing connection of ht 22kv under ground cable, detecting fault by applying surge current 1.5 times the rated current & finding exact location of fault with pico equipment and repair the same immediately complete all as specified and as directed by the eng.in.charge.note: necessary jointing kit to be measured and paid separately in respective items. 85 m&l for servicing / testing the following equipment of distribution transformer 22 / 0.44kv: ( a ) ir value of winding ( b ) de carbonizing all cable connection. ( c ) earth resistance checking ( d ) replacement of silica gel complete all as specifiedand directed by engg in charge 86 painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove oil stains, dust etc and applying one coat of synthetic enamel paint by spray paint incl writing sm no. / mes no. of capacity 160 / 250 kva transformer completeall as specified and directed by eng.in.charge. 87 supply onlyassembly of approved make filled with silica gel suitable for transformer of capacity 160 / 250 kvadistribution transformer complete all as specified and as directed by eng.in.charge. 88 supply and fix brass spindle for terminal on ht side threaded complete with nut, washer etc of suitable dia for transformer of capacity 160kva to 250kva complete all as specified and directed by engg.in.charge. 89 supply and fix brass spindle for terminal on lt side threaded complete with nut, washer etc of suitable dia for transformer of capacity 160kva to 250kva complete all as specified and directed by engg.in.charge. 90 supply and fix ceramic bushing and gasket on lt side of transformer of capacity 160 to 250 kva 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 91 supply and fixing in replacement of complete gasket ( cork sheet ) 6mm thick with and incl conical rubber bush complete all as specifiedand directed by engg in charge 92 m&l forservicing / testinght 22kv vcb panel rupturing capacity 26 / 3 mva, 1250 amps including calibration, decarburizing , troubleshooting, repairing, replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmeter , vaf meter, selector switch all illuminated indications for r y b phase, by qualified technical personcomplete all as specified and by the engr in charge.note: necessary spare parts, need to replace will be paid in respective item. 93 supply only voltage indicator lamp ( red, yellow and orange ) 220 v, ac for servecing / replacement the ht 22kv vcb complete all as specified and directed by engg.in.charge. 94 supply only control fuse, hrc, 2 / 4 / 6 amp for servecing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 95 supply only ht tape for servecing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge 96 supply only monoplast tape for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 97 supply only high voltageover current protection relay for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 98 supply only earth fault relay for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 99 supply only auxillary contacts for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 100 supply only space heater alongwith thermostat for ht vcb panel including electric connection complete all as specified and directed by engg.in.charge. 101 supply only master trip relay suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 102 supply only contact arm suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 103 supply only shunt release coil on, 110 v, dc suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 104 supply only shunt release coil off, 110 v, dc suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 105 supply only key locksfor servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 106 supply only switch operating assembly servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 107 m&l for shutter assembly suitable for ht 22 kv vertical draw type vcb complete all as specified and directed by engr in charge. 108 m&l for taking down carefully existing serviceable switch air break, gang operated outdoor, any type of capacity upto 22 kv, servicing to the operating mechanism, greasing etc of all joints for smooth operation, with & including replacement of burnt male / female contact where required, re fixing the switch air break, gang operated outdoor, testing, complete all as specified and as directed. 109 taking down unserviceable god of any capacity and supply and installation ht 22kv / 200amps outdoor type god including dropout fuse assembly complete all required at site etc complete all as specifed and directed by engineer in charge. 110 supply & fixing dropout fuse 23 swgcomplete all as specified and directed by engg.in.charge. 111 s&f in replacement copper stripof size 32x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by engg.in.charge 112 s&f copper stripof size 20x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by engg.in.charge 113 s&f in replacement single phase smps based battery backed power pack for supply back up for trip coil, protection relay, indication, & other load in ht panels, working input voltage 90 to 300 volt ac, output 110 volts dc with backup for 15 20 min, complete all as specifiedand directed by engg in charge 114 s&f lightning arresters ht 22 kv 65 kilo amp non linear expulsion type transmission class with standard fittings confirming to is 3070 ( part i ) 1985, including dismantling & taking down old unserviceable lightning arresters, complete all as specifiedand directed by engg in charge 115 s&f disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 22000 volts, including dismantling & taking down old unserviceable insulator, complete all as specifiedand directed by engg in charge 116 supply & laying xlpe insulated , screened, pvc bedded, galvanizedsteel strip or wire armoured heavy duty electric power cable with aluminum conductor, 22000 v grade, cross sectional area of3 core 95 sqmm in trenchescomplete all as specifiedand directed by engg in charge 117 supply & laying un reinforced precast cement concrete cable cover class hv type 1, flat, size 300mm x 180mm x 40mm complete all as specifiedand directed by engg in charge 118 m&l for earthing complete with copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper strip of size 20x3 mm all as specified and shown in electric plate no 3 of mes ssr part i 2009 including earthwork, pcc chamber, ci cover, protection and watering pipe, funnel, mesh etc all as required at site and complete all as specifiedand directed by engg in charge.note: ( i ) . 7.5 rm copper strip in deemed to be included in quoted rates beyond 7.5 rm strip shall be measured and paid separately. ( ii ) . earth resistance of earth pit should be less than 2 ohms. on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. ( iii ) rate quoted by the tenderer is deemed to include salt & charcoal upto & above 450 mm top of copper plate. ( iv ) soil registance test if required shall be the responsbility of contractor without any extra cost. 119 excavation in trenches , n exc 1.5 m wide and n, exc 1.5 m in depth for foundation, etc. or for shafts, wells cesspits, manholes, peir holes. etc 1.5 m n exc 10 sqm on plan and n exc, 1.5 m in depth and getting outcomplete all as specifiedand directed by engg in charge 120 returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft / soil complete all as specifiedand directed by engg in charge 121 removing excavated soil not exc 50m depositing where directed at a level not exc 1.5m above the starting point complete all as specifiedand directed by engg in charge 122 m&l sand cushioning for ug cable protection / ducts, consolidated sand compacted with clean dry sand complete all as specifiedand directed by engg in charge 123 boringfor road crossingin any kind ofsoil / rock strata complete all as specifiedand directed by engg in charge 124 supply & laying gi pipe light graded of size 50mm diain trenches and fixing on wall / poleswith help of suitable size ms clamp for cable protectioncomplete all as specifiedand directed by engg in charge 125 supply & laying gi pipe light graded of size 80mm diain trenches and fixing on wall / poleswith help of suitable size ms clamp for cable protection complete all as specifiedand directed by engg in charge 126 supply, fixing & stretcing aluminium conductor steel reinforced ( acsr ) of any type and size fixedon existing steel tubular / pcc ht / lt pole fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by engineer in charge. notes : i ) the acsr conductors shall be conforming to is 398 ( part ii ) and as specified in ssrpart i .ii ) the unit rate quoted shall alsobe deemed to include for supply and fixing of binding wire, aluminium tapes etc which shall not be included in the weight of conductors for payment.iii ) weight of conductors shall be determined by measuring the horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size multiplied by lenght of span and 3 % extra shall be added for sag, jointing, jumpers etc.iv ) weight of the conductors shall be calculated from the nominal weights given in tables in the relevant is. 127 m&l for painting of transformer foundation with two coats of obd after complete scrapping of old paint / whitewash and making good surface complete all as specifiedand directed by engg in charge 128 m&l cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape inclusive of one primer coat, one under coat and one finishing coat of paint complete all as spd and directed by engg.in.charge. 129 m&l for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of gi and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateno. 5 of ssr part i of 2009 & as specified or indicated and testing on completion including exaction / earth work in any type of strata pcc ( 1:3:6 ) type c1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1:2:4 ) type b1 ( reinforced with welded steel wire fabric ( xpm ) weight not less than 4 kg / sqm ) , funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 25x4 mm with gi protection pipe of 20 mm medium grade 7.5 meter long, etccomplete all as specified and as directed by engr in charge.note: ( i ) venders are bound to get earthing result upto 5 ohm for single earthings and 3 ohm with the grid of two earthing.any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by contractor. ( ii ) excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. ( iii ) refill the pit with m&l for black cotton soil 1 cum. ( iv ) on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. ( v ) taking down all items in respect of existing earthing is included in the cost deemed to be quoted by contractor....
33866797 supply installation testing commissioning of battery backup system for vcb panel at new globe mill pumping station...
33756276 electrification work in pump house, office room, store room, 3.3 kv vcb panel room/ pump house work...
33080425 auction sale of lot no: 8.0 lot name: u/s 11 kv ht vcb panel...
32798770 barvi water works...m&r to barvi water works ,jambhul annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul. 2nd call...
32272253 tender for barvi water works...m&r to barvi water works ,jambhul ........annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul....
31869068 construction of vertical extension of 2 floors of new laboratory building at c met, pune. sh: replacement of existing 11kv ht vcb panel with suitable new vcb panel at c met, pune....
31837520 replacement of 11 kv ht mocb panel with 11 kv ht vcb panel at ats complex, mumbai....
31830970 replacement of 11 kv ht mocb panel with 11 kv ht vcb panel at ats complex, mumbai....
31791179 tender for barvi water works...m&r to barvi water works ,jambhul ........annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul....
31757532 providing supplying spares and rectification of electrical and mechanical equipment in pump house and near waghur dam annual maintenance for year 2022 23 supply and installation of 33kv, 3 core, aluminum armored cable outdoor cable end termination joint kit ( isi make ) . work involve cutting of existing joint, measure insulation value and making joint, refixing to system. 2 supply & erecting 3.3 kv 3 core 300 sq.mm alum. armoured cable. 3 supply & erecting 3.3 kv 3 core 70 / 95sq.mm alum. armoured cable. 4 excavation and backfilling of trench for adjustment of33 kv cable for joint. 5 supply and installation of lt out door cable joint for auxiliary transformer 6 supply and installation of 33 kv isolator set of 3 with alignment 7 dismantailing of existing 33 kv isolator complete set 8 repairing of 33 kv existingisolator along with required spares & hardware’s with alignment for smooth operations 9 supply and installation of 33 kva b switchfor auxiliary transformer 10 dismantailing of existing 33 kva b switchcomplete set 11 repairing of 33 kv existing a b switchincluding required spares & hardwares with alignment for smooth operations 12 supply and installation of 33 kv horn gap unit of 3 with fuses 13 repairing of 33 kv horn gap post for proper fixing 14 supply and installation of horn gap fuses 15 supply and installation of33 kv , d o unit of 3 with fuses 16 supply and installation of d o fuse 50 amps 17 supply and installation of 33 kv, lasingle post 18 supply and installation ofpost insulator with pin 19 supply & installation of 33 kv outdoor pt 20 supply & installation of 33 kv outdoor ct 21 repairing of existing 33 kv outdoor pt 22 repairing of existing 33 kv outdoor ct 23 repairing of post insulator and cleaning by ctc 24 tightening of all conductors in sub station as preventiv maintenance 25 transformer, 33 kv / 3.3 kv, 3000 kva complete overhauling, bucolz relay, bdv test, ppm test, tightening of all 33 kv bushing and conductors removing air from bucolz relay, cleaning of all bushing with ctc. attending leakages if any. 26 transformer, 33 kv / 3.3 kv, 3000 kva. oil filtration with test report. 27 supply & installation of buchloz relay for 33 kv out door transformer. 28 supply & installation of breather with silica jel for 33 kv outdoor transformer. 29 auxiliary transformer 33 kv / 440 volts complete preventive maintenance. tightening of all bushing, gaskets, conductors and cable terminations, earthing etc 30 oil filtration of auxiliary transformer 33 kv / 440 volts 31 complete overhauling of 33 kv out door vcb.all control wiring tightening, spring changing motor testing, earthing tightening etc 32 earthing of sub station replace existing material by new material to improve value 33 spreading clear metal in yard 34 painting of complete structure of sub stations by red oxide as primer andaluminum paint 35 illumination in yard.supply and installation of fused tubes, bulbs wiring testing etc 36 supply and installationof indoor cable joint for 3.3 kv, 500 hp motor, coppermulti strandfor h t motor dismantailing of exi etcsting burnt out / heated cable joint, cleaning cable by ctcpreparing new joint and ht taping. 37 repairing of existing joint of 3.3 kv h t motor.cleaning by ctc to clean cable and lugs for carbon free particle’s, re taping by h t tape 38 supply and installationofh t capacitor ( 120kvar unit ) 39 supply ofl t capacitor 40 installation of l t capacitor 41 supply of h thrc fuse 3.3 kv / 50 amps capacity with barrel for capacitor 42 500 hp, 3.3 kv, h t motor complete overhauling with alignment. shifting motor from foundation by disconnecting cable, pulley etc. dismantailing / taking out rotor from stator. h t warnishing to rotor and stator by heating process inspection of bearings, end cover bearing housing etc 43 providing & fitting bearing to the motor de side including necessary fixtures etc. complete. 44 providing & fitting bearing to the motor nde side including necessary fixtures etc. complete. 45 workshop work for filling weared out bearing housing 46 rotor balancing for proper alignment to improve life of motor 47 painting to motor by red oxide as primer and two coats by smoke gray paint 48 preventive maintenance of motor. inspection of bearings, cable joints, foundation bolts tightness, cleaning of cooling system greasing to de nde bearings 49 replace of motor from foundation to other foundation 50 alignment of motor to pump 51 500 h.p. 375 kw. pump set ( kirloskar make ) remove of existing old splitcasing pump from row water pumping station for repairing purpose. 52 providing & fitting impeller to the pump including necessary fixtures etc. complete 53 providing & fitting pump shaft to the pump including necessary fixtures etc complete. 54 providing & fitting casing wear ring &suction side ) to the pump including necessary fixtures etc. complete. 55 providing & fitting casing wear ring ( delivery side ) to the pump including necessary fixtures etc. complete. 56 providing & fitting split gland to the pump including necessary fixtures etc. complete. 57 providing & fitting bearing holder de to the pump including necessary fixtures etc. complete. 58 rewinding motor of eot crane. 59 repairing panel board of eot crane with required accessories. 60 providing & fitting bearing cover de to the pump including necessary fixtures etc. complete. 61 providing & fitting bearing cap to the pump including necessary fixtures etc. complete. 62 providing & fitting split lantern ring to the pump including necessary fixtures etc. complete. 63 providing & fitting liquid deflector rubber to the pump including necessary fixtures etc. complete. 64 providing & fitting shaft sleeve to the pump including necessary fixtures etc. complete. 65 providing & fitting shaft sleeve nutto the pump including necessary fixtures etc. complete. 66 providing & fitting bearing nut to the pump including necessary fixtures etc. complete. 67 providing & fitting bearing lock nut to the pump including necessary fixtures etc. complete. 68 providing & fitting sealing tube to the pump including necessary fixtures etc. complete. 69 providing & fitting set of gaskets to the pump including necessary fixtures etc. complete. 70 providing & fitting set of ring to the pump including necessary fixtures etc. complete. 71 providing & fitting set of fasteners to the pump including necessary fixtures etc. complete. 72 providing & fitting gland packing to the pump including necessary fixtures etc. complete. 73 providing & fitting bearings to the pump including necessary fixtures etc. complete. 74 providing & fitting love joy coupling with rubber & studs complete with suitable bore size 75 providing nylon slings belts of 5 to 10 tan capacity ( for lifting purpose ) 76 pump coloring charges 77 eot crane maintenance work. inspection of main drum, motors, panel relays etc 78 replace faulty or burnt mcb in eot crane panel 79 overhauling ofmotors with replacement of bearings for eot crane 80 cleaning complete both rail of eot crane 81 h t panel inspection of all parts in one vcb panel for smooth operations 82 supply and installation of closing and tripping coil 83 supply and installation of spring charging motor 84 repairing of spring charging motor 85 supply and installation of spring charging drum mechanism 86 repair of vcb, inspection for smooth operations and trolley alignment 87 preventive maintenance of vcb 88 supply & installation of closing / tripping coil of vcb indoor 89 supply & installation of earth fault relay 90 supply & installation of thermostat 91 supply & installation of breaker control switches 92 lt panel supply and replacement of faulty / burnt outspaares 93 preventive maintenance of l.t. panel. 94 control and relay panel wiring replace by new whereever damaged 95 battery charger panel supply and installation of burnt out spares 96 preventive maintenance of battery charger panel 97 supply and installation of 110 volt dc batteries 98 preventive maintenance of 55 batteries 99 illumination system supply and installation of burnt tube lights, exhaust fans mcb, etc. 100 supplying spanner ( ring ) 101 supplying spanner ( fix ) 102 supplying multi meters 1000 amp. 103 supplying megger 1 kv ( 1000 volts ) 104 supplying pipe wrentch 18” 105 supplying pipe wrentch 24” 106 supplying pipe wrentch 36” 107 supplying chain pulley 2 tone 108 supplying chain pulley 3 tone 109 supplying hammer heavy weight up to 10 kg. 110 supplying air blower for panel, vcbcleaning purpose....
31654110 supply of set of spare for filter for dj/vcbset of spare for filter for dj/vcb,set of spare for filter for dj/vcb panel of siemag make model no.sb.ss.60.sh4 one set comprising of 7 items = 07 nos. as per drg.no. bsl/elw/sk no.9098....
31460865 tender for the work of repairing of 11kv ht vcb panel, lt panel,dg set, transformer, metering kiosk and allied work at bharat ratna dr .babasaheb ambedkar memorial, sec 15 airoli....
30983398 supply installation testing and commissioning of battery backup system for vcb panel and various ancillary electrical works at dadar pumping...
30717985 supply installation testing commissioning sitc of new 11 kv ht vcb panels and 2 nos. 630 kva transformers for substation mgims khs sevagram sitc of new 11 kv ht vcb panels and 2 nos. 630 kva transformers for substation at mgims khs sevagram...
30630834 auction sale of 1 voltage stabilizer 2 voltage stabilizer 3 voltage stabilizer 4 500 kva transformer ket make 5 500 kva transformer kirloskar make 6 630 kva transformer kirloskar make 7 voltage stabilizer automech electrical make 8 heat treatment old panel crompton parkinson make 9 busbar panel enterprises make 10 cooling pump control desk eta dogiguard make 11 d .g. control desk sorana digiguard make 12 synchronising control desk sorana digiguard make 13 load control desk sorana digiguard make 14 high voltage ct mahadev ele. pune make 15 out door breaker panel cg make 16 out door breaker panel cg make 17 heavy foundry breaker panel schneidler make 18 heavy foundry furnace acb l t make 19 hrc control panel shree control make 20 vcb controle panel pce make 21 vcb controle panel 22 rtcc panel kec make 23 battery charger panel nana make 24 flot coin boost battery charger panel sm interface make 25 controle panel kbl make 26 compressor kbl make 27 air driyer 28 air driyer filter 29 ele .motor kirloskar make 30 ele .motor kirloskar make 31 vcb panel vibha corporation make 32 distribution panel ...
30536105 tender document for [supply, fixing spare parts and servicing 22 kv megawin make indoor vcb panel and gec alsthom make lt acb panel installed at our container freight station, dronagiri, navi mumbai...
30435358 bids are invited for 1. manpower outsourcing services minimum wage skilled; others; electrician outsourcingof services for manning & operation of e/m installation comprising ht vcb, panel board, feeder pillar, street lights and auto power factor control at kalina campin 03 (three) shifts of 8 hourseach per day including sundays and holidays by providing and deploymentone electrician (skilled) in each shift including routine maintence, attending and rectification of breakdowns daily,cleaning and up keep of surrounding areas of installations and maintaining record of daily break down of installation as and when maintenance carried outall as directed by engineer in charge. timings of shifts: shall be as directed by engineer in charge. note: electrical items/spares as per requirement of site shall be arranged for issue through baby indent by the department. old unserviceableitems/spares shall be deposited by the contractor at their own cost to age e/m (af) mumbai store yard. , 2. manpower outsourcing services minimum wage skilled; others; electrician outsourcingof services for manning & operation of e/m installation comprising ltfeeder pillar box/panel and auto power factor control at coo hangar,121 hf annex bldgs and porta cabin in 03 (three) shifts of 8 hourseach per day including sunday and holiday by providing and deployment one electrician (skilled) in each shift including routine maintence , attending and rectification of breakdowns daily,cleaning and up keep of surrounding areas of installations and maintaining record of daily break down of installation as and when maintenance carried outall as directed by engineer in charge.timings of shifts: shall be as directed by engineer in charge.note: electrical items/spares as per requirement of site shall be arranged for issue through baby indent by the department. old unserviceableitems/spares shall be deposited by the contractor at their own cost to age e/m (af) mumbai store yard. , 3. manpower outsourcing ...
29461804 tender for various repairing and development work, erection of chlorinator, repairing and maintenance of water supply, providing and fixing, testing of vcb panel, laying of drainage line, patch work of road....
29307781 supply of rmu unit vcb panel , ...
29153951 repair and comprehensive maintenance of transformer vcb panel ht cable and connected items at af station ojhar repair and comprehensive maintenance of transformer vcb panel ht cable and connected items at af station ojhar...
28988984 scw vcb panel at erai dam cstps...
28984759 bids are invited for boq total quantity : 1 vcb panels, 11 kv, 800 amps, indoor type...
28835652 tender for scw vcb panel at erai dam cstps...
28487885 repair and comprehensive maintenance of transformer , vcb , panel , ht cable and connected items at af station devlali...
28408203 supply installation testing commissioning of new 11 kv ht vcb panels and 2 nos . 630 kva transformers for substation at mgims khs sevagram sitc of new 11 kv ht vcb panels and 2 nos . 630 kva transformers for substation at mgims khs , sevagram...
28388572 execution of electrical works relating to modification of ht metering system . supply , installation , testing and commissioning of 33 kv vcb panel , metering kiosks , compact sub stations including supply and laying of ht and lt cables...
28263998 scw 11kv 630a vcb panel at erai dam...
28079566 supply , service , installation , testing and commissioning of transformer , god and rsj pole , lightning arrester , indoor vcb panel , cables , terminal kits , earthing material along with allied electrical works at cip turbhe...
28079511 pumping machinery installation, repairing and maintenance supplying of spare part at raw and pure water pumping station. ( 2 nd call ) 1 latur city water supply project dhanegaon head works (manjaraproject) vt pumphead 77metre.dischange 0473 lps/ 1703m3/ hr ( 17,03,000lph)model c24tcstages 2, makewpil, speed 1180 rpm. reparingwith bearing shaft sleavesbussypumpoil,oilchemberbushingttplatebush,gland with dismentling, erecting labour charges. 2 10mtcapacityeotcranewithelectricallyoperated, cpblock and travelling trolley lift 10 m., span 11.5 mtr. make hercules, starter, contactswithsupplying, erectingwithlabour charges. 3 3.3kvvssmotor (spdp)speed 1500rpm.kw 510,current 109a. hp 700hpmake alstomrotorbrsig,windingbearings with repairing and rewinding, dismentling, erecting labour charges. 4 repairingand rewindingof transformer 33 kv/ 3.3 kvwith oltc,rtcc,avrandmarshallingboxcapacity 2500kvamake transdelta (aurangabad) 5 repairingandrewinding auxiliarytransformer (forl.t. supply) 3.3 kv / 0.433 kv capacity 100 kva make transdelta. 6 repairing/ replacementofhtsubstationwith33kv,abswitch, lighting arrestor, disc insulator, pin insulator etc. 7 repairing/ replacement 33kvindoor vcbpanel insubstation room33kvfullydrawout typevacuumcircuit beaker630amp capacitywithctsratio 75/ 5aandptsratio33kv/ 110v/ 100 va burden / tpidmtl relay, ht fiber size vaccum contractor, duck, insulator, mail, femail contact. 8 repairingof 3.3kvvcbandisolator panel insubstationroom 800 a 3.3 kv vcb panel. 9 repairing of 3.3 kv break switch panel 10 repairing/ replacement of 3.3kv 100kvarcapacitor bank, transformer, reactor, etc. 11 3.3 kvvcb800 afor buscoupler, repair withmaterial with labour 12 repairing/ replacementof3.3kv400avaccumcontractorsfor motor feeder, contacts, fuse 200 amp. 13 repairing/ replacementof3.3kv200abreakerswitchwithhrc fuses, coil, contacts, necessary material 14 repairing/ replacement of ltpanel board630a air circuit breaker,contacts coil, mechanical work 15 supplyingand erectingof power cables33 kv, 3 core x 185 sqmmxlpe(e) grade aluminiumconductor armoured cable (from two pote to vcb, vcb to transformer) 16 supplyinganderectingof 11kv, 3 core x120 sqmmxlpe(e) grade aluminium conductor armoured cable (motor control panel to motor) 17 supplyinganderectingof 11kv, 3 core x300 sqmmxlpe(e) grade aluminium conductor armoured cable (2500 kva transformer to motor feeder panel) 18 supplyinganderectingof 3 1/2core x240 sqmmaluminium armoured cable (for auxiliary and lt panel board) 19 supplying and erecting of control cable 10 core x 2.5 sq.mm 20 supplying and erecting of 7 core x 1.5 sq.mm 21 supplying and erecting of 4 core x 1.5 sq.mm 22 supplying and erecting of 4 core x 2.5 sq.mm 23 supplying and erecting of 2 core x 1.5 sq.mm 24 supplying and erecting of 10 core x 1.5 sq.mm 25 repairing of ht capacitors 3.3 kv make madhavkvar 100 26 purewaterpumpingstationat harangulwtp vtpumphead 67meterdischange1123m3/ hr (11,23,000lph)speed 1480 rpmmodelstages 2makewpilshaft sleaves, bearing, rubber packing,ttplatebushing,nutbolt,oil,grease withdismentling, erecting labour charges. 27 removing, dismentling of 700 hp electrical motor 28 removing, dismentling of 442 hp electrical motor 29 removing, dismentling of 700 hp pump set 30 removing, dismentling of 442 hp pump set 31 motor / pump fitting and erecting loading and unloading transportation 32 7.5mtcapacityeotcrane,cpblockandtravellingtrolleylift 8 m, span 11.5 mtr make hercules starter moter, repairing, rewinding with material. 33 3.3kvvssmotor (spdp)speed 1500rpm.kw 330,current 72a. hp 442hpmake alstomrewinding, repairsworkwith bearing breazing. 34 rewinding, repairingof transformer 33kv/ 3.3kvwitholtc, rtcc, avrand marshalling box capacity 1600 kvamake transdelta, transfor fress oil, breather. 35 repairingof auxiliary transformer (for l.t. supply) 3.3 kv / 0.433kvcapacity 315kvamake transdelta.repairingwork with t/f fresh oil 36 repairing andmaintenance of ht substation with 33 kvab switch, lighting arrestor, disc insulator, pin insulator cunductor. 37 repairingof 33kvvcb_630ampfor isolationof 3.3kvsupply, repair with material 38 repairingof 3.3kvvcbandisolator panel insubstationroom 800 a 3.3 kv vcb panel repair with material 39 repairingof 3.3kv 100kvarcapacitorbank, transform, fuse, capacitor, supply and repair 40 supplying and erecting of 125 a tp sfu h.t. fuses 41 supplying and erecting of 63 a tp sfu h.t. fuses 42 supplying and erecting of 100 a tp sfu h.t. fuses 43 supplying and erecting of 250 a tp sfu h.t. fuses 44 cable trays of iron works 45 repairing of ups system 3 kva capacity 3 kva battery panel 46 repairing / replacement of battery 12 volts exide make 47 electrification, bulb, metering, led, unit 48 fire fighting and safety equipments 49 tools plyer, cutter, spaner set, ring spaner set 50 earthing 51 हहहह ऀऀऀऀऀऀऀऀ ऀ य य यय यय य यय य ऀऀऀऀ 50 hp wash water electric motor and centrifugal pump repair, rewinding with bearing cupler. 52 air blower 50 hp electric motor repairing, rewinding with material, bearing, oil, grease, v belt. 53 repairing of non return valve size 450 mm dia 54 repairing of non return valve size 600 mm dia 55 supplying and erecting 63 amper mccb 56 supplying and erecting 100 amper mccb 57 supplying and erecting 200 amper mccb 58 supplying and erecting 250 amper mccb 59 supplying and erecting 400 amper mccb 60 supplying and erecting 630 amper mccb 61 supplying and erecting lt contractor of verious size as below 100 amper 62 125 amper 63 185 amper 64 225amper 65 330 amper 66 400 amper 67 630 amper 68 c.t. relay 63 amper 69 125 amper 70 150 amper 71 225 amper 72 330 amper 73 630 amper 74 vaccume timer 75 l.t. single phase privater 76 ats rewinding for 50 hp 77 ats rewinding for 75 hp 78 ats rewinding for 150 hp 79 ats rewinding for 250 hp 80 gear box repairing work with gear oil bearing. 81 electric motor rewinding with material 1 hp 82 electric motor rewinding with material 2 hp 83 electric motor rewinding with material 3 hp 84 electric motor rewinding with material 5 hp 85 electric motor rewinding with material 25 hp 86 electric motor rewinding with material 50 hp 87 electric motor rewinding with material 75 hp 88 electric motor rewinding with material 150 hp 89 electric motor rewinding with material 250 hp 90 submersible monoblock pumpset rewinding repairing bush bearing set empler shaft for 3 hp 91 5 hp 92 7.5 hp 93 10 hp 94 15 hp 95 75 hp 96 l.t. panel board indicator ammter, voltmeter, selector switch push button on / off ct (25/5, 100/5 amper 200/5 amper, 600/5 amper 97 sluice value repair size 80 mm dia check nut 98 spendal rod 99 joint rassi 100 nut bolt 101 gland cap 102 supplying of grease 103 supplying of gear oil 104 sluice value repair size 100 mm dia check nut 105 spendal rod 106 joint rassi 107 nut bolt 108 gland cap 109 sluice value repair size 150 mm dia check nut 110 spendal rod 111 joint rassi 112 nut bolt 113 gland cap 114 sluice value repair size 200 mm dia check nut 115 spendal rod 116 joint rassi 117 nut bolt 118 gland cap 119 sluice value repair size 250 mm dia check nut 120 spendal rod 121 joint rassi 122 nut bolt 123 gland cap 124 sluice value repair size 300 mm dia check nut 125 spendal rod 126 joint rassi 127 nut bolt 128 gland cap 129 sluice value repair size 350 mm dia check nut 130 spendal rod 131 joint rassi 132 nut bolt 133 gland cap 134 sluice value repair size 400 mm dia check nut 135 spendal rod 136 joint rassi 137 nut bolt 138 gland cap 139 sluice value repair size 500 mm dia check nut 140 spendal rod 141 joint rassi 142 nut bolt 143 gland cap 144 sluice value repair size 600 mm dia check nut 145 spendal rod 146 joint rassi 147 nut bolt 148 gland cap 149 laturcitywatersupplyprojectdhanegaondamandpurewater pumping station at harangul resin cost indoor single phase doublecorectsupplyinganderectingof33kv15vaclass1/ 10 p 10 150 resingcost indoor singlecoreptsupplyinganderectingof 100 va capacity 33 kv / 3 / 110 volt / 3 make hupen 151 indoor type termination kit supplying and erecting for 33 kv (e) x lpe unscreened 3 core x 95 sqmm power cable 152 indoor type termination kit supplying and erecting for 33 kv (e) x lpe unscreened 3 core x 120 sqmm power cable 153 indoor type termination kit supplying and erecting for 33 kv (e) x lpe unscreened 3 core x 185 sqmm power cable 154 outdoortypeterminationkitsupplyinganderectingfor3.3/ 6.6 kvxlpe (e) unscrened 3 core cable size 300 sqmm 155 outdoortypeterminationkitsupplyinganderectingfor3.3/ 6.6 kvxlpe (e) unscrened 3 core cable size 400 sqmm 156 supplyinganderectingof aluminiumlugssuitable for 33.0kv xlpe (e) unscrened 3 core cable size 185 sqmm 157 25 sqmm aluminium cable lugs 158 50 sqmm aluminium cable lugs 159 95 sqmm aluminium cable lugs 160 95 sqmm copper cable lugs 161 120 sqmm aluminium cable lugs 162 300 sqmm aluminium cable lugs 163 400 sqmm aluminium cable lugs 164 supplyinganderectingofresincast indoor singlephasedouble corectratio75/5.5amp33kv100vaclass/ 10 p 10made hupen 165 supplying and erecting of ht fiber sheet (as per sample) 166 supplying and erecting of ht c type fiber sheet (as per sample) 167 supplying and erecting of ht tubler type fuses 63 amp 168 supplying and erecting of 100 amp ht tubler type fuses 169 supplying and erecting of 200 amp ht tubler type fuses 170 supplying of of do fuses 171 supplying and erecting of chlorinater 900 kg tonner 172 alum grade 1 173 bleaching powder grade 1 isi mark, is 1065 174 pac powder 25 kg bag 175 aluminium hydralic 176 electrical, mechanical engineer 177 supervisor (electrical / mechanical) 178 electrician (iti passed) 179 pump operator (iti passed) (electrical) 180 filter operator (any graduate) 181 fitter (iti) 182 labour (unscheled)...
27853729 pumping machinery installation, repairing and maintenance supplying of spare part at raw and pure water pumping station. 1 latur city water supply project dhanegaon head works ( manjara project ) vt pump head 77 metre. dischange 0473 lps / 1703 m3 / hr ( 17, 03, 000 lph ) model c 24 tc stages 2, make wpil, speed 1180 rpm. reparing with bearing shaft sleaves bussy pump oil, oil chember bushing tt plate bush, gland with dismentling, erecting labour charges. 2 10 mt capacity eot crane with electrically operated, cp block and travelling trolley lift 10 m., span 11.5 mtr. make hercules, starter, contacts with supplying, erecting with labour charges. 3 3.3 kv vss motor ( spdp ) speed 1500 rpm. kw 510, current 109 a.hp 700 hp make alstom rotor brsig, winding bearings with repairing and rewinding, dismentling, erecting labour charges. 4 repairing and rewinding of transformer 33 kv / 3.3 kv with oltc, rtcc, avr and marshalling box capacity 2500 kva make transdelta ( aurangabad ) 5 repairing and rewindingauxiliary transformer ( for l.t. supply ) 3.3 kv / 0.433 kv capacity 100 kva make transdelta. 6 repairing / replacement of ht substation with 33 kv, ab switch, lighting arrestor, disc insulator, pin insulator etc. 7 repairing / replacement 33 kv indoor vcb panel in substation room 33 kv fully draw out type vacuum circuit beaker 630 amp capacity with cts ratio 75 / 5 a and pts ratio 33 kv / 110 v / 100 va burden / tpidmtl relay, ht fiber size vaccum contractor, duck, insulator, mail, femail contact. 8 repairing of 3.3 kv vcb and isolator panel in substation room 800 a 3.3 kv vcb panel. 9 repairing of 3.3 kv break switch panel 10 repairing / replacement of 3.3 kv 100 kvar capacitor bank, transformer, reactor, etc. 11 3.3 kv vcb 800 a for bus coupler, repair with material with labour 12 repairing / replacement of 3.3 kv 400 a vaccum contractors for motor feeder, contacts, fuse 200 amp. 13 repairing / replacement of 3.3 kv 200 a breaker switch with hrc fuses, coil, contacts, necessary material 14 repairing / replacement of lt panel board 630 a air circuit breaker, contacts coil, mechanical work 15 supplying and erecting of power cables 33 kv, 3 core x 185 sqmm xlpe ( e ) grade aluminium conductor armoured cable ( from two pote to vcb, vcb to transformer ) 16 supplying and erecting of 11 kv, 3 core x 120 sqmm xlpe ( e ) grade aluminiumconductor armoured cable ( motor control panel to motor ) 17 supplying and erecting of 11 kv, 3 core x 300 sqmm xlpe ( e ) grade aluminiumconductor armoured cable ( 2500 kva transformer to motor feeder panel ) 18 supplying and erecting of 3 1 / 2 core x 240 sqmm aluminium armoured cable ( for auxiliary and lt panel board ) 19 supplying and erecting of control cable 10 core x 2.5 sq.mm 20 supplying and erecting of 7 core x 1.5 sq.mm 21 supplying and erecting of 4 core x 1.5 sq.mm 22 supplying and erecting of 4 core x 2.5 sq.mm 23 supplying and erecting of 2 core x 1.5 sq.mm 24 supplying and erecting of 10 core x 1.5 sq.mm 25 repairing of ht capacitors 3.3 kv make madhavkvar 100 26 pure water pumping station at harangul wtpvt pump head 67 meter dischange 1123 m3 / hr ( 11, 23, 000 lph ) speed 1480 rpm model stages 2 make wpil shaft sleaves, bearing, rubber packing, tt plate bushing, nut bolt, oil, greasewith dismentling, erecting labour charges. 27 removing, dismentling of 700 hp electrical motor 28 removing, dismentling of 442 hp electrical motor 29 removing, dismentling of 700 hp pump set 30 removing, dismentling of 442 hppump set 31 motor / pump fitting and erecting loading and unloading transportation 32 7.5 mt capacity eot crane, cp block and travelling trolley lift 8 m, span 11.5 mtrmake hercules starter moter, repairing, rewindingwith material. 33 3.3 kv vss motor ( spdp ) speed 1500 rpm. kw 330, current 72 a.hp 442 hp make alstom rewinding, repairs work with bearing breazing. 34 rewinding, repairing of transformer 33 kv / 3.3 kv with oltc, rtcc, avr and marshalling box capacity 1600 kva make transdelta, transfor fress oil, breather. 35 repairing of auxiliary transformer ( for l.t. supply ) 3.3 kv / 0.433 kv capacity 315 kva make transdelta. repairing work with t / f fresh oil 36 repairing and maintenance of ht substation with 33 kv ab switch, lighting arrestor, disc insulator, pin insulator cunductor. 37 repairing of 33 kv vcb_630 amp for isolation of 3.3 kv supply, repair with material 38 repairing of 3.3 kv vcb and isolator panel in substation room 800 a 3.3 kv vcb panel repair with material 39 repairing of 3.3 kv 100 kvar capacitor bank, transform, fuse, capacitor, supply and repair 40 supplying and erecting of 125 a tp sfu h.t. fuses 41 supplying and erecting of 63 a tp sfu h.t. fuses 42 supplying and erecting of 100 a tp sfu h.t. fuses 43 supplying and erecting of 250 a tp sfu h.t. fuses 44 cable trays of iron works 45 repairing of ups system 3 kva capacity 3 kva battery panel 46 repairing / replacement of battery 12 volts exide make 47 electrification, bulb, metering, led, unit 48 fire fighting and safety equipments 49 tools plyer, cutter, spaner set, ring spaner set 50 50 hp wash water electric motor and centrifugal pump repair, rewinding with bearing cupler. 51 air blower 50 hp electric motor repairing, rewinding with material, bearing, oil, grease, v belt. 52 repairing of non return valve size 450 mm dia 53 repairing of non return valve size 600 mm dia 54 supplying and erecting 63 amper mccb 55 supplying and erecting 100 amper mccb 56 supplying and erecting 200 amper mccb 57 supplying and erecting 250 amper mccb 58 supplying and erecting 400 amper mccb 59 supplying and erecting 630 amper mccb 60 supplying and erecting lt contractor of verious size as below 100 amper 61 c.t. relay 63 amper 62 vaccume timer 63 l.t. single phase privater 64 ats rewinding for 50 hp 65 ats rewinding for 75 hp 66 ats rewinding for 150 hp 67 ats rewinding for 250 hp 68 gear box repairing work with gear oil bearing. 69 electric motor rewinding with material 1 hp 70 electric motor rewinding with material 2 hp 71 electric motor rewinding with material 3 hp 72 electric motor rewinding with material 5 hp 73 electric motor rewinding with material 25 hp 74 electric motor rewinding with material 50 hp 75 electric motor rewinding with material 75 hp 76 electric motor rewinding with material 150 hp 77 electric motor rewinding with material 250 hp 78 submersible monoblock pumpset rewinding repairing bush bearing set empler shaft for 3 hp 79 l.t. panel board indicator ammter, voltmeter, selector switch push button on / off ct ( 25 / 5, 100 / 5 amper 200 / 5 amper, 600 / 5 amper 80 sluice value repair size 80 mm dia check nut 81 spendal rod 82 joint rassi 83 supplying of grease 84 supplying of gear oil 85 sluice value repair size 100 mm dia check nut 86 spendal rod 87 joint rassi 88 sluice value repair size 150 mm dia check nut 89 spendal rod 90 joint rassi 91 sluice value repair size 200 mm diacheck nut 92 spendal rod 93 joint rassi 94 sluice value repair size 250 mm dia check nut 95 spendal rod 96 joint rassi 97 sluice value repair size 300 mm dia check nut 98 spendal rod 99 joint rassi 100 sluice value repair size 350 mm dia check nut 101 spendal rod 102 joint rassi 103 sluice value repair size 400 mm dia check nut 104 spendal rod 105 joint rassi 106 sluice value repair size 500 mm dia check nut 107 spendal rod 108 joint rassi 109 sluice value repair size 600 mm dia check nut 110 spendal rod 111 joint rassi 112 latur city water supply project dhanegaon dam and pure water pumping station at harangul resin cost indoor single phase double core ct supplying and erecting of 33 kv 15 va class 1 / 10 p 10 113 resing cost indoor single core pt supplying and erecting of 100 va capacity 33 kv / 3 / 110 volt / 3 make hupen 114 indoor type termination kit supplying and erecting for 33 kv ( e ) x lpe unscreened 3 core x 95 sqmm power cable 115 indoor type termination kit supplying and erecting for 33 kv ( e ) x lpe unscreened 3 core x 120 sqmm power cable 116 indoor type termination kit supplying and erecting for 33 kv ( e ) x lpe unscreened 3 core x 185 sqmm power cable 117 outdoor type termination kit supplying and erecting for 3.3 / 6.6 kvxlpe ( e ) unscrened 3 core cable size 300 sqmm 118 outdoor type termination kit supplying and erecting for 3.3 / 6.6 kvxlpe ( e ) unscrened 3 core cable size 400 sqmm 119 supplying and erecting of aluminium lugs suitable for 33.0 kv xlpe ( e ) unscrened 3 core cable size 185 sqmm 120 25 sqmm aluminium cable lugs 121 50 sqmm aluminium cable lugs 122 95 sqmm aluminium cable lugs 123 95 sqmm copper cablelugs 124 120 sqmm aluminium cable lugs 125 300 sqmm aluminium cable lugs 126 400 sqmm aluminium cable lugs 127 supplying and erecting of resin cast indoor single phase double core ct ratio 75 / 5.5 amp 33 kv 100 va class / 10 p 10 made hupen 128 supplying and erecting of ht fiber sheet ( as per sample ) 129 supplying and erecting of ht c type fiber sheet ( as per sample ) 130 supplying and erecting of ht tubler type fuses 63 amp 131 supplying and erecting of 100 amp ht tubler type fuses 132 supplying and erecting of 200 amp ht tubler type fuses 133 supplying of of do fuses 134 supplying and erecting of chlorinater 900 kg tonner 135 alum grade 1 136 bleaching powder grade 1 isi mark, is 1065 137 pac powder 25 kg bag 138 aluminium hydralic 139 electrical, mechanical engineer 140 supervisor ( electrical / mechanical ) 141 electrician ( iti passed ) 142 pump operator ( iti passed ) ( electrical ) 143 filter operator ( any graduate ) 144 fitter ( iti ) 145 labour ( unscheled ) ...
27607934 annual maintenance work of electrical work, conveyor belt patch and vulcanizing joint, laying of cable, jointing, tressing, power and control, removal of cable, supply, testing, commissioning of vcb panel, cleaning of rail track....
27559206 tender for scw vcb panel at erai dam...
27354797 supply, erection. testing, commissioning of ht panel 6.6.kv, 25 ka, motor feeders 07 nos., incomer 02 nos. with bus coupler of 16o0 amp, complete vcb panel and allied works at sina mad ha lift irrigation scheme, at futjawalgaon, tal. madha, dist. solapur....