Western Coalfields Limited - Maharashtra
39747057 bids are invited for custom bid for services repairing of electroteknica make nflp vcb panels sr no 1062 to 1076 at ukni deep opencast mine wani north area total quantity :...
39747057 bids are invited for custom bid for services repairing of electroteknica make nflp vcb panels sr no 1062 to 1076 at ukni deep opencast mine wani north area total quantity :...
39687896 tender for items of work a) lift & escalator sitc of electric traction passenger cum stretcher lift with · doors type : copo/topo doors with frame made from ss 441 grade solid (non cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with ss door architraves/frames the lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by nabl accredited or independent test laboratory).· lift car enclosure made from ss 441 grade solid (non cladded) sheet of 1.5mm, thick with hairline finish with frame made from ms girders, bracing of adequate size with minimum safety factor of 5, with toe guard apron, with necessary false ceiling with adequate led lights, blower/fan for ventilation & ss chequered plate flooring, handrails, mirror, emergency light etc. the lift car interior design shall be done as per the directions of engineer in charge.· cop with ss face plate having metallic push buttons with braille code & luminous indicator around button with fpi, scrolling up/dn led indicator & with / without attendant key switch, owd with audio visual alarm, vas in marathi, hindi & english with intercom system with telephone instrument in lift car, lmr & fcc/ground floor. · lop with ss face plate having recess/surface push button box for all landings with scrolling up/dn led indicator having metallic push buttons with braille code & luminous indicator around button with cpi, lift car arrival & next travel direction audio visual indication at all landings. lift controller of simplex full collective based on microprocessor/ plc with vvvf drive having closed loop control system, with ibms compatible having necessary port. the controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, vip call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from cop etc. the system can record information for minimum 30 latest faults, with real time clock management and handheld keypad with lcd screen for view and setting of parameters, the control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm crca sheet with powder coating with ip54 protection class. · ard complete with necessary smf vrla batteries.· fireman controller having fireman switch at fire landing. · cctv surveillance system comprises of 2nos minimum 2.0mp fhd ip based vandal proof dome camera in lift car & in lmr/inside lift shaft top aimed on lift machinery & controller with nvr kept in lmr/fcc with hdr data backup for min. 90 days with min. 20 fhd tv monitor, to be kept in fcc/lmr as directed by engineer in charge.· lift machine of gearless pmsm of suitable kw with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by nabl accredited or independent test laboratory), with traction pulley, osg, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on lmr floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· other mechanical parts such as t section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, ms pit ladder etc. erected with necessary steel work.· minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/rcc work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. lft.· general: job includes entire procedure of obtaining all necessary erection permissions & license to work the lift from electrical inspector(lifts) with submission to the engineer in charge.· the above rate includes fully comprehensive amc for one year from the date of commissioning. sitc of electric traction passenger cum stretcher lift with · rated capacity : 13 passenger/ 884kg · floors : b+g+21 floor (23 stops/23 landings) · travel : 84.5mtrs · location of lift machine: mr/mrl· rated speed : 2.5 mps vs· car/landing door clear opening of 1100/1200 mm wide x 2000 mm high· clear car size of 2200mm wide x 2500mm deep x 2250mm high · lift shaft available having clear size of 2675 mm wide x 1725 mm deep, ......mm pit depth 4950 mm overhead. job b) sitc of electric traction passenger cum stretcher lift with · rated capacity : 13 passenger/ 884kg · floors : b+g+16 floor (18 stops/18 landings) · travel : 76.5mtrs · location of lift machine: mr/mrl· rated speed : 2.5mps vs· car/landing door clear opening of 1100/1200 mm wide x 2000 mm high· clear car size of 2200mm wide x 2500mm deep x 2250mm high · lift shaft available having clear size of 2625 mm wide x 1725 m deep, 4950 mm pit depth, 4950 mm overhead. job c) sitc of electric traction passenger cum stretcher/hospital lift with · rated capacity : 13 passenger/ 884kg · floors : b+g+1 floor (4 stops/4 landings) · travel : 9.5mtrs · location of lift machine: mr/mrl· rated speed : 1.5mps vs· car/landing door clear opening of 1100/1200 mm wide x 2000 mm high· clear car size of 2200mm wide x 2500mm deep x 2250mm high · lift shaft available having clear size of 2500 mm wide x 1700 mm deep, 4550 mm pit depth, ………mm overhead. job 2 supply, installation, testing & commissioning of escalator 6.5 m rise fully ss finish with inclination 30/ 35 degrees, step width of 600 to 1000 mm, and speed of 0.5 to 0.65 m/s, self supporting handrails centred on glass panels. only government officers will be allowed for material inspection prior to approval. test report for inspected material will be provided. one year product warranty can be extended as per requirement. public flow of 6000 to 8000 passengers per hour. 18kn/step load carrying capacity. b) mechanical stack parking 1 supply, installation, testing & commissioning of 2 wheeler stack parkingoperation : hold to run spring operated key switch operationsafety: electromagnetic locks, emergency stop switch1. hydraulic stack park 2. independent single stack park 1. lockers on both the sides in a descending direction2. emergency stop switch.3. hold to run spring operated key switch4. centre support holding the side columns and side beams with 3u combination.5. ip 55 protection for electrical material.6. drive through protection cover over hydraulic pipe and electrical cables.7. non return valve8. galvanised protection cover for balancing chain and electro magnet.9. special profile for entry plate for better grip of tyres while driving over the platform.10. power pack with submerged motor and self company make control panel.11. hydraulic cylinder – two stage single acting, single stroke cylinder12.safty device solenoid operated mechanical lock arrangement13.maximum load capacity of the system – 500 kg14. connect power for power pack in amps 1.1 kw each 2 supply, installation, testing & commissioning of 4 wheeler stack parkingoperation: hold to run spring operated key switch operationsafety: lockers on every 100 mm, emergency stop switch1. lockers on both the sides in a descending direction2. emergency stop switch.3. hold to run spring operated key switch4. centre support holding the side columns and side beams with 3u combination.5. ip 55 protection for electrical material.6. drive through protection cover over hydraulic pipe and electrical cables.7. non return valve8. galvanised protection cover for balancing chain and electro magnet.9. special profile for entry plate for better grip of tyres while driving over the platform.10. power pack with submerged motor. 11.model hydraulic stack 210 12. quantity 1 system – 2/3 car13. length 5000 mm 14. standard width 2000 mm & standard height 2000 mm 15. standard weight 2000 kg 16. vertical drive unit type hydraulic cylinder & chain type motor 3 hp / 2.2 kw, 415vac, 50hz speed 4 m/ min drive hydraulic cylinder & chain type 17. power source main ac 415v, 3 ph, 50 hz lighting ac 220v, 1 ph, 50 hz 18. operating box 3 way encloser box with up, down & key switch19. control relay logic20. safety devices key selector switch to stop the system mechanical locking arrangment21. finishing powder coated c) swimming pool 1 sitc of magiline swimming pool liner filter job16.15m x 6.65m x 1.8m (depth)for this swimming pool filter specification as bellow pipless filtration unit nfx 30, discharge 30 cum/hr, boosting for automatic cleaning robot at 2 cum/hr & suction 32 cum/hr. 30,000 lit per hour capacity avg time of running 2.5 to 3 hours motor capacity 2 hppool materials, included: pvc liner – plain blue (tiles not required) filtration units pool wall lights programming electric box maintenance accessories kit start up chemical products 3 steps ss ladder d) fire fighting 1 supplying, installation, testing and commissioning of main fire pump (mfp/ep) suitable for water discharge of 2850 lpm at 110 m head and 165 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 112 kw or of suitable kw capacity for manual/automatic operation and consisting of following:(a) horizontal type, single/multi stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520.(b) squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325.(c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003) complete, as per specification no. ff mfp/ssc/msc/ep. rate shall include dlp of 2 years against commissioning of the project. each 2 supplying, installation, testing and commissioning of jockey fire pump (jp) suitable for water discharge of 180 lpm at 110 m head and 165 m head driven by electric motor 415 volts, 3 phase 50 hz, ac supply of 15 kw or of suitable kw capacity for manual/automatic operation and consisting of following :(a) horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(ss410 grade), mechanical seal conforming to is 1520.(b) suitable kw squirrel cage induction motor, tefc, synchronous speed 3000 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 325.(c) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (isc code 536 as per is 2932 of 2003)complete, as per specification no. ff mfp/jp. rate shall include dlp of 2 years against commissioning of the project. each 3 supply, installation , testing & commissioning of diesel engine driven main pump of horizontal centrifugal multi stage pump suitable for water discharge of 2850 lpm at 110 m head and 165 m head confirming to is 5120 1977. the pump shall be coupled to suitable hp diesel engine heat exchanger type with speed of 1800 /1500 rpm and complete set shall be mounted on commom base frame . batteries & battery leads with stand, diesel tank 500 ltr with stand & he piping, fuel piping with valves. coupling guard, silencer, 24 v starting arrangement, oil level indicator & oil coolant and other standard accessories, and foundation bolts , etc. complete. the heat insulation with al cladding for silencer line up to 60 mtr included in the installation the pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. the shut off head should not be more than 120% of rated head. rate shall include dlp of 2 years against commissioning of the project. each 4 supplying and erecting g.i. pipe ‘c’ class erw 250 mm dia with necessary fittings complete as per specification no. ff pp mtr 5 supplying and erecting g.i. pipe ‘c’ class erw 300 mm dia with necessary fittings complete as per specification no. ff pp mtr 6 supplying and erecting 250 mm dia. cast iron double flange rising stem sluice valve complete with pn25 pressure rating, as per specification no. ff vl/sv nos 7 supplying and erecting 300 mm dia. cast iron double flange rising stem sluice valve complete with pn25 pressure rating, as per specification no. ff vl/sv 8 sitc of abc type extinguisher 6kgs. is 15683 each 9 sitc at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “fire” in black and gold. cost shall be inclusive of providing ms stand duly painted over a coat of primer. bucket shall be fabricated with stand to install 4 nos of buckets. set 10 providing and fixing forged brass ball valve with ss ball suitable for test pressure of not less than 30 kg / sq.cm of the following size : 25 nb each 11 providing & fixing of installation control valve with turbine type automatic alarm gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturers specifications complete as required. (consider 2 nos . isolation valve for each alarm gong) 150 nb size each 12 supply and installation of flexible braided hose pipe of 25mm dia with both end socket for fixing the sprinkler to ranger.consider length of flexible piece as per below. flexible connectors should be supported with separate expansion bolts & not on the false ceiling frame work. the pressure carrying capacity of hose shall be 12 bar. the supporting arrangement to get approved from ceiling vendor prior to execution. 1500 mm long each 13 supply, installation, testing & commissioning of en 54 certified digital evac pa controller with built in audio message generator (multi message), capable of adding 12 zones in the system and expandable upto 400 zones with 14x 4 audio matrix withaudio matrix with full dsp functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. amplifier redundany, 4 x 100v audio inputs and built in 8 zone speaker line outputs. 8000 fault, warning and event conditions log. built in message manager for 100 emergency/business calls up to 85 minutes. should be able to send 2 different pre recorded messages simultaneously (message should be in 2 languages english & hindi). shall be able to handle up to 2000watt load, 10 routers, 6 call stations, 128 speaker zones. the controller should integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast and fault diagnosis, audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover etc. complete with cords, connectors, power supply & required accessories. note system should operates in two channel operation & fulfill the fas cause & effect matrix requirements. each 14 supplying, erecting, testing and commissioning 1000 w amplifier suitable to operate on 230 volts a.c. / 12 volts d.c. supply complete as per specification no. ff pa/afr each 15 novec 1230 tube based gas suppression system main electrical panelssitc of fk 5 1 12 (fluoroketone) clean agent direct low pressure (dlp) pre engineered panel gas suppression system, gas shall be zero odp and gwp less than 1., agent shall be ul listed, the system shall be designed accordance to nfpa 2001 (latest edition), the clean agent is stored peso approved cylinder as compressed liquid, super pressurized with dry nitrogen to 13.5 bar to 16 bar. cylinder shall be equipped with dlp valve, pressure switch(ce/ul marked) and pressure gauge need to be integrated on dlp valve itself to monitor the cylinder pressure. ul listed detection tube shall be manufactured from specially processed polymer material to achieve the desired heat detection and delivery characteristics., and shall cover and routed to each compartment of panel, end line adapter to be placed at the termination point of detection tube for charging the nitrogen., pressure switch should be integrated with master control unit for audio visual alarm in the even of fire & system discharge. master control unit should have provision to interface system with main control fire alarm system and bms. clean agent total flooding system server rooms1. sitc of clean agent novec gas /naf 227 gas suppression system consisting of seamless cylinders of 80,120 & 140 litre each and each filled with clean agent novec gas / naf 227 gas pressurised to 25 bar pressure complete with common pipe manifold of seamless pipe, pilot cyinder, electric actuator, relief valve, pressure guages, high pressure rubber hose, high velocity nozzles, brackets, floor mounting assembly consisting of ms angle boxing. contractor to provide all necessary certificates of approval of cylinder from cce, and certificate of filling to required pressure and weight.2. sitc of complete with socketweld fittings and supports astm schedule 80 seamless pipes.3. sitc addressable fire alarm cum gas release panel complete with cross zoning and 4 zone gas discharge cards with complete with power card, 15 ah smf battery, digital ammeter, each gas zone complete with isolate, abort switch, discharge switch, timer knob, evacuation alert, gas discharge and complete with relay for actuation of gas solenoid valve. job 17 clean agent suppression system kitchen area1. sitc, of commercial kitchen system light weight stainless steel body f/k agent (wetchemical) required capacity, filled with f/k agent, electrical actuated valve assembly and necessary fitting, cylinder brackets with screw & cabinet, stainless steel fitting joints, elbow, reducers etc, ss piping and fiting, nozzles with required velocity, sensor cable, manual release, kitchen suppression panel, 2 zone, hooter cum strobe, abort switch, gas shut off valve (size 1), with fitings all pipe etc, cables and accessories include all other requuired accessories e electrical ht items 1 sitc of 22kv gis breaker at 220/22kv hinjewadi ph 1 s/s as per msetcl specification rated voltage 24kv, rated power frequency withstand voltage 50hz, rated lightning impulse withstand voltage 125kv, rated busbar current 1600amp, rated peak withstand current 124 ka, rated short time current 3 sec, internal arc classification 40ka 1sec. nos 2 sitc of 22 kv heat shrink indoor touch proof termination (aj)kit for xlpe 3 c x 400 sq.mm. kit 3 sitc of 22kv heat shrink straight through joint, (aj) kit for xlpe 3 c x 400 sq.mm. kit 4 sitc of xlpe 22kv ht, 3c,xlpe cable 400 sq.mm.cable (round armourd) with cable route marker, cable laid over rcc cable trench / directly buried / cable tray or as per msedcl approved cable laying arrangement from 220/22kv ehv sub station. hinjewadi, two feeders with three run cable mtr 5 sitc of advance maintenance free earthing system consisting of 80 mm diameter x 3 meter long, made from low carbon steel pipe, galvanised with 2 nos of stainless steel nut & bolt, suitable for lug size 50 mm x 6 mm x 100 mm, and cross section area 616 mm2, along with 50 kgs. of premium ground improving compound duly modified premium quality for excellent electrical conductivity of approved make. during earth pit boring/drilling, if the water logging or water seepage in the earth pit (due to high ground water level). however, the earth pit gets moist / sludgy. in such cases, use carbon based chemical compounds. nos 6 excavation permission charges for 22kv ht, 3c,xlpe cable 400 sq.mm.cable (round armourd) with cable route marker, from 220/22kv ehv sub station. hinjewadi, two feeders with three run cable including obtaining necessary road cutting permission from pcmc/ pmrda / midc mtr 7 sitc of 22kv indoor vcb panel with incomer feeder for 22 kv 1600 amps 25ka/1 sec vaccum circuit breker with c& r panel with o/c + e/f realy, spring charging motor 230v ac, draw out & isolation horizontal, ct ratio 400/5amp, protection relay triple pole idmlt relay with rs 485comm. port with trip circuit supervision 3 o / c + 1 e / f with high set o / c setting : 20 % 200 % of 5a., e / f setting: 10 % 40% of 5a, with high set for both o/c & e/f aux. vtg 110v dc, type : rej601/p154 or as per msedcl/msetcl approval spec. nos 8 sitc of 22kv indoor vcb panel bus coupler for 22 kv 1600 amps 25ka/1 sec vaccum circuit breker with c& r panel with o/c + e/f realy, spring charging motor 230v ac, draw out & isolation horizontal, ct ratio 400/5amp, protection relay triple pole idmlt relay with rs 485comm. port with trip circuit supervision 3 o / c + 1 e / f with high set o / c setting : 20 % 200 % of 5a., e / f setting: 10 % 40% of 5a, with high set for both o/c & e/f aux. vtg 110v dc, type : rej601/p154 or as per msedcl /msetcl approval spec. nos 9 sitc of outgoing feeder with differential protection relay with indoor panel 22kv i,1250amp, 26.3 ka, vaccume circuit breaker with c & r panel with differential protection relay,tripping & closing coil 110v dc, spring charging motor 230v ac.draw out & isolation horizontal aux contact 4 no + 4 nc, protection relay triple pole idmlt relay with rs 485comm. port with trip circuit supervision 3 o / c + 1 e / f with high set o / c setting : 20 % 200 % of 5a., e / f setting: 10 % 40% of 5a, with high set for both o/c & e/f aux. vtg 110v dc, type : rej601/p154 or as per msedcl/msetcl approval spec. nos 10 sitc of 22 kv heat shrink indoor touch proof termination (aj)kit for xlpe 3 c x 300 sq.mm. kit 11 sitc of 22/0.433kv 160 amp switch fuse unit (sfu) of the following rating including necessary accessories like enclosure, fuse base ,fuse links etc. and requirement of the item with the supply authority (msedcl) for station transformer protection 12 sitc of 22 kv h.t. metering cubical (compact outdoor type) licensee approved fabricated with 2mm.(14 swg) m.s.sheets with supporting angle and channel, painted with powder coating or epoxy paint shade light grey, copper bus bar electronic security lock and mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( c.t.p.t cover) interlock with meter doors, epoxy coated 3 nos c.t having required ratio between 5/5a to 300/5a burden 10 va class 0.2 epoxy terminal block suitable for provided tri vector meter, and provision for incoming and outgoing cables etc complete duly tested by licensee and with necessary test certificates and erected on the provided plinth. (ref sld a+b metering kiosk section) nos 13 sitc of outgoing feeder with differential protection relay with indoor panel 22kv i,1250amp, 26.3 ka, vaccume circuit breaker with c & r panel with differential protection relay as per msedcl/msetcl approved specs( 1 in 1out) nos 14 sitc of outgoing feeder with differential protection relay with indoor panel 22kv i,1250amp, 26.3 ka, vaccume circuit breaker with c & r panel with differential protection relay as per msedcl/msetcl approved specs( 1 in 5out) f) transformer 1 sitc of 3 phase, 22/0.433 kv, 50 hz., 2500 kva, 22/0.415 kv oil( easter) type transformer with nitrogen filled and naturally cooled outdoor type, copper wound non sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type a winding insulation (kraft paper), with hv tapping (with on load tap changer) on load +5 to 15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2930 watts at 50% load, 8085 watts at 100% load as per is:1180 (part 1) : 2014 with necessary permissions of electrical inspector, as per specification no ss tr nsl. as per msedcl approval g) electrical lt/ht panels & system 1 sitc of pcc panel (refer sld dwg main pcc panel block a+b ) busbar: 6300a, 4 pole, 50ka aluminium bus bars with colour coded heat shrinkable insulating sleeves. incomer: 2500a, 4 pole mccb, 50ka 10 nos. protection and measurement as per specification.metering :one set of incomer phase indicating lights, shall be protected by 2 amps mcb’s. 1 nos. with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 2 sitc of floor meter panel with 630a ats , duel source meter & 630amp mccb r458t compatible to bms at electrical shaft (refer sld floor meter panel)with ethernet module with rs485 for atys(modbus gateway compatible for bms system) (rs485 msdbus communication for atys p) nos 3 supplying, erecting, testing and commissioning isolator panel with 4000amp fp acb fabricated with 2mm.(14 swg) m.s.sheets with supporting angle and channel, painted with powder coating or epoxy paint shade light grey, alu bus bar size in electrical shaft (refer sld end feed boxl)with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 4 sitc of 200 kvar rtpfc panel with incomer:500a,tp mccb 36 ka with spreader, ex roh, and auxiliary block with lsig , indication lamp r,yb ,on, current transformer 1600/5a , 12tage apfc relay 230v, 15 kvar x 2 , 10 kvar x 1 ,5 kvar x 2 , 25 kvar x 1 fixed type ,al busbar 60 x = 1500amp, with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 5 sitc of 100 kvar rtpfc panel with incomer:250a,tp mccb 36 ka with spreader, ex roh, and auxiliary block with lsig , indication lamp r,yb ,on, current transformer 1600/5a , 10tage apfc relay 230v, 25 kvar x 2 ,15 kvar x 1, 10 kvar x 2 ,5 kvar x 2,al busbar 60 x = 1500amp, with ethernet module with rs485 for atys (modbus gateway ) nos 6 sitc of 22kv indoor vcb panel with incomer feeder for 22 kv 1600 amps 26.3 ka vaccum circuit breker with c& r panel with o/c + e/f realy as per msedcl approval spec. ( 1 in 2out) nos 7 sitc of outgoing feeder with differential protection relay with indoor panel 22kv i,1250amp, 26.3 ka, vaccume circuit breaker with c & r panel with differential protection relay as per msedcl approved specs( 1 in 2out) nos 8 sitc of pcc panel for pmpml (ref sld pcc panel for pmpl) panel shall be powder coated fabrication, body 2 mm ,door & load bearing 2mm with base mounting.indoor type .colour simens grey rl7032 . 7 tank process .incoming acb 4000 a 4p 50 ka with microprocessor release lsig with bodbus communication mccb 125a tpp 36ka for spd al busbar 2500 160 x 12 = current density with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 9 sitc of battery charging distribution panel unit (ref sld pmpl battery charging distribution panel 1 2) busbar: 4000a, 4 pole, 50ka aluminium bus bars with colour coded heat shrinkable insulating sleeves. incomer: 4000a, 4 pole acb, outgoing: 400a mccb 14 nos &630a mccb with ats 1 nos. protection and measurement as per specification.metering:one set of incomer phase indicating lights, shall be protected by 2 amps mcb’s. 1 nos with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 10 sitc of single phase, 240v, common service panel up to the max load of 140kw, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, with incomer 320amp 4fpmccb, outgoing 63amp 4 pole mcb with mfm, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation with ethernet module with rs485 for atys (modbus gateway compatible for bms system) 11 sitc of single phase, 240v, common service panel up to the max load of 378kw, powder coated crca 14 swg sheet, outdoor type, having ip54,ik10 protection, with incomer 800amp 4fpmccb, outgoing 63amp 4 pole mcb with mfm, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / cc foundation with ethernet module with rs485 for atys (modbus gateway compatible for bms system) h) dg set, synchronising panel & etc. 1 1600 kw / 2000 kva, diesel generating set prime rated comprising of: “cummins” model qsk60 g4, radiator cooled, diesel engine developing 2319 bhp at 1500 rpm, complete with standard accessories. coupled to “stamford” alternator rated at 1600 kw / 2000 kva at 415v, mounted on channel iron base frame complete and 02 no 12 v batteries.controller pc3.3 with fuel tank 990 ltrs capacity (supplied loose, located outside canopy)standard alternator is class h to temp rise limited to h @40deg c ambient.factory testing as per pl std qap for 3hrs.with acoustic enclosure with alternator mounted isolator panel with manually fix type acb as per powerica standard design.(breaker make – l&t/ schneider/reputed) with including dg fuel system ,dg exhaust system including with all necessary stack, heat insulation with required density and alu cladding as per norms approx 90mtr,piping etc. required accessories job 2 sitc of amf cum synchronising panel for 5x2000kva dg set as per powerica standard design as per is8623. incomer acb 3200a, 3p, 50ka, o/l, s/c release – 5nos kwh meter 5nos ef relay 5nos load manager conserv em6400 5nos battery charger smps based enko make 5nos buscoupler acb 6300a, 3p, 50ka, o/l, s/c release – 1no plc for ldss allenbradly make 1no indoor type panel ip52 busbar aluminium 6000a tpn 50ka breaker make schneider nw /l&t u power protection & safties in dg controller shall not be duplicated in panel. common outgoing breaker not offered/ not under powerica scope.with ethernet module with rs485 for atys (modbus gateway compatible for bms system) nos 3 sitc of hsd transfer gear pumps capable of delivering 250lph diesel at a head of 15m. pump is coupled with 3 hp, 3 phase, 415v 50hz flame proof motor. pump motor set mounted on common base frame. including m.s. class ‘b’ (heavy duty) pipes, including fittings like bends and required all necessary accessories ( for supply line) nos 4 sitc of hsd transfer gear pumps capable of delivering 110lph diesel at a head of 10m. pump is coupled with 1.5 hp, 3 phase, 415v 50hz flame proof motor. pump motor set mounted on common base frame.including fittings like bends and required all necessary accessories ( this is to transfer overflowed diesel back to underground tank.) nos 5 peso approval for 30 kl ug tank which includes, obtaining required local nocs, approvals from all local statutory bodies to receive final peso approval. ( statutory fees to be borned by customer, also the required documents to be submit by customer as and when required to obtained the peso aprroval i) bustrunking & accessories 1 providing & erecting hot dipped galvanised for ladder type cable tray with cover manufactured from 14 swg (2 mm thick) gi sheet of 1500 mm width & 75 mm height complete with necessary hardware mtr 2 supply of make 4000a,(sba 230n2) 4p, 415v sandwich aluminium bustrunking with suitable external alu earthing straight length – indoor ( ip 55 ) mtr 3 supply of 3200a,(sba 175n2) 4p, 415v sandwich aluminium bustrunking with 2 runs of suitable external alu earthing indoor (ip 55 ) mtr 4 supply of 2000a,(sba 175n2) 4p, 415v sandwich aluminium bustrunking with 2 runs of suitable external alu earthing indoor (ip 55 ) mtr 5 supply of 4000a,(sba 230n2) 4p, 415v sandwich aluminium bustrunking with suitable external alu earthing straight length – indoor ( ip 66 ) mtr 6 supply & installation of adaptor box for trasformer/ panel end for aluminium bustrunking nos 7 supply & installation of 3200a phase crossover for aluminium bustrunking nos 8 supply & installation of 4000a,(sba 175n2) 4p, 415v flanged end for aluminium bustrunking nos 9 supply & installation of 3200a,(sba 175n2) 4p, 415v flanged end for aluminium bustrunking nos 10 supply & installation of 2000a,(sba 175n2) 4p, 415v flanged end for aluminium bustrunking nos 11 supply & installation of rubber bellow for aluminium bustrunking nos 12 supply & installation of flexible link for aluminium bustrunking nos 13 supply & installation of 4000a vertical elbow for aluminium bustrunking nos 14 supply & installation of 3200a vertical elbow for aluminium bustrunking nos 15 supply & installation of 2000a vertical elbow for aluminium bustrunking nos 16 supply & installation of end cover for aluminium bustrunking nos 17 supply & installation of end feed box with isolator mccb for aluminium bustrunking nos 18 supply & installation of 630amp tap off box for aluminium bustrunking j) ev charging 1 sitc of 25 nos. 160 kw dc ev chargers (50 nos. pmpml buses. ) double gun charger (rated power: 160kw/ input voltage: 415v ac/ electrical protection: o/c, s/c, spd, isolation, ef, /user authorization: qr code/ communication protocol: ocpp v1.6 j.) nos 2 sitc of 600 nos. 3.3 kw ac 2 wheeler charging points charger (rated output current: 16amp, input voltage: 220v, electrical protection: over current, short circuit, isolation, user authorization: qr code, network connectivity: gsm/ gprs, place of installation: indoor and outdoor, installation: wall mounted.) nos 3 sitc of 175 nos. 7.4 kw ac 4 wheeler charging points charger (rated output current: 32a, input voltage: 220v, electrical protection: over current, over/under voltage, surge protection, short circuit protection, earth leakage, ground fault, user authorization: qr code, network connectivity: gsm/ gprs, place of installation: indoor and outdoor, ingress protection: ip 55, charging mode standard: iec 61851 1 charging mode 3. k) façade lighthing 1 sitc of led rgb/rgbw floodlighting luminaire for facade lighting with die cast aluminium housing, powder coated finish . the beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. luminaire shall be complete with a driver and capable of operating at line voltage without any separate power supply from 100 270 v ac, 50 hz with power factor > 0.9. the fixture shall be suitable to operate at an ambient temperature range of 10°c to +50°c and shall be ip 65 and ik 06 rated.lifetime shall be at least l70:50000 burning hours at 50°c. luminaire shall conform to bis (is 10322) and shall be complete with all necessary accessories required for the proper working of the fixture including weatherproof connection cables, waterproof connectors etc. as required. make phillips, lighting technology, wipro, syska, jaguar, crompton, wipro, bajaj, havells, osram, orient.facade area 14500 sq.mt, perimeter of building 320 mtr, height of the building 88.50 mtr. l) pumping system 1 sitc of ss vertical inline pump with positive suction. each pump shall have three phase electric motor of s1 duty. the pump shall have cast iron head, base plate ss shaft / impeller / intermediate chamber along with motor, pressure gauge with isolation cock, isolation valve, nrv on delivery line. isolation valve, stainer (with by pass) at suction. pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia), flexible mettalic pump collector of stainless steel corrugated tubing with stainless steel overbraid and carbon steel flanges. the pump shall be suitable for auto/ manual operation. the installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. the flexible connectors shall be installed on both suction and delivery side of suitable size and standard length including electrical control panel with 1 vfd for operation & control of pump sets including provision of pressure vessel and capacity not less than 2 times the total suction volume of the pump to be provided as per directions of engineer in charge as per manufacturers standard. domestic pumps ugwt to ohwt (pump discharge = 240 lpm. head = 115m) (3 w + 1 s) set 2 sitc of ss vertical inline pump with positive suction. each pump shall have three phase electric motor of s1 duty. the pump shall have cast iron head, base plate ss shaft / impeller / intermediate chamber along with motor, pressure gauge with isolation cock, isolation valve, nrv on delivery line. isolation valve, stainer (with by pass) at suction. pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia), flexible mettalic pump collector of stainless steel corrugated tubing with stainless steel overbraid and carbon steel flanges. the pump shall be suitable for auto/ manual operation. the installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. the flexible connectors shall be installed on both suction and delivery side of suitable size and standard length including electrical control panel with 1 vfd for operation & control of pump sets including provision of pressure vessel and capacity not less than 2 times the total suction volume of the pump to be provided as per directions of engineer in charge as per manufacturers standard. drinking pumps ugwt to ohwt (pump discharge = 100 lpm, head = 115m) (2 w + 1 s) set 3 sitc of ss vertical inline pump with positive suction. each pump shall have three phase electric motor of s1 duty. the pump shall have cast iron head, base plate ss shaft / impeller / intermediate chamber along with motor, pressure gauge with isolation cock, isolation valve, nrv on delivery line. isolation valve, stainer (with by pass) at suction. pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia), flexible mettalic pump collector of stainless steel corrugated tubing with stainless steel overbraid and carbon steel flanges. the pump shall be suitable for auto/ manual operation. the installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. the flexible connectors shall be installed on both suction and delivery side of suitable size and standard length including electrical control panel with 1 vfd for operation & control of pump sets including provision of pressure vessel and capacity not less than 2 times the total suction volume of the pump to be provided as per directions of engineer in charge as per manufacturers standard. flushing pumps stp to ohwt (pump discharge = 250 lpm, head = 125 m) (3 w + 1 s) 4 sitc of stainless steel vertical in line pump sets consisting of 1 working & 1 standby pump having built in overload protection, motor housing, suction plate, bottom screen & all screws to be of stainless steel, motor cover & pump housing to be of corrosion proof cast iron, pump to have stainless steel impeller & double mechanical seals in oil chambers, including necessary supports/ foundations, main suction header & delivery header along with y strainers,isolation and n.r valve, pressure guages & pressure switches, all necessary fittings,and cable from panels to the individual pumps etc including electrical control panel with 1 vfd for operation & control of pump sets including provision of pressure vessel. complete as per directions of engineer in charge (terrace top 3 floor). 1 pump to run on vfd and the vfd shall be transferrable to any of the pumps. domestic terrace booster pump (pump discharge = 150 lpm, head =25m) (1 w + 1 s) set 5 sitc of vertical monoblock sewage/ mud pump with 1500 lpm @ 8 mwc , 5.5 kw (7.5 hp) (1w+1s) m) lv system & misc. 1 sitc of electric 360° occupancy slim pir presenting room ceiling mount 230v energy saving motion sensor, white css54e_we by making necessary arrangement/recess in wall to make it flush with surface. nos 2 video wall displays vhr r, vht e, vmt e, vmt u seriespanel size/class 54.6, type ips resolution 1920 * 1080, pixel pitch(mm) 0.63mm(h) * 0.63mm(v), active display area(mm) 1209.6mm * 680.4mm, brightness max 700cd/m2, contrast ratio 1200:1viewing angle(h/v) 178/178, response time(g to g) 8ms, display colors 8 bit 16.7mcolor gamut 72%, operation hour 24/7, haze 28%, dynamic c/r 500,000:1, h scanning frequency 57.3khz ~ 70khz, v scanning frequency 48hz ~ 75hz, maximum pixel frequency 77mhz, input rgb dvi d, display port 1.2, input video hdmi 2.0, input hdcp 2.2, input audio stereo mini jack usb only f/w upgrade, output rgb dp1.2(loop out), output audio stereo mini jack, external sensor detachable type(ir), power supply ac 240 v, 50/60 hz, power consumption 242wtypical [w/h] 136w, sleep mode less than 0.5w mechanicalnspec dimension(mm) set 1211.0 x 681.7 x 70 weight (kg) set 19.4 kg bezel width (mm) 0.9mm job 3 sitc for access control(human face: pin card ( em prox ) bluetooth supported device user profiles 50,000 facelogs 500,000 ,recognition * 3.5 ips lcd (touch screen ) , ip65 ,wifi , poe , access control feature ( door lock ) ,reports,integration with ms sql, my sql, oracle,,postgre, db2*web apis for integration with third,party application email,notification,enterprise structure and report,schedular,import user master data and export 500,000 events storage)metal electro magnetic lock ( em lock single )exit push button l bracket installation implementation training and one year support. job 4 sitc of intercom ip phone epabx system 1. spark200 matrix pure ip hardware platfrom for unified communication server pre loaded with 1 vocoder. on board cpu and ac power supply in 1u enclosure. max. ip trunks: 99 (license free) max. ip users: 2100. max. vocoder channels: 248 max. vms channels: 64. prasar ucs ent license built in2. sparsh vp510e proprietary ip phone with poe (voip protocol: proprietary • ethernet ports: 2 (pc andlan) • display: 240 x 64 pixels graphical lcd with backlit • color: black • programmable keys: 4 context sensitive keys, 16 dss keys. power supply: poe bms system software : web based graphical software meeting the requirements in the given i/o summary & technical specifications including configuration and facility to create / provide the graphic mapping for all i/o summary points, animate the graphics, navigation between pages, display of logs, changing the time zones, popup alarms, configurable password protection for building mgmt system as per specifications. software shall be able to communicate with lon works, bacnet, modbus devices simultaneously, with unlimited user license capacity.ul listed, btl certified, hardware interface/soft integrators with inbuilt webbrowser for third party equipment, open protocol software integration. these integrators shall be of same make as ddcs and shall contain all necessary ports for software intgeration of below mentioed equipment.ddc controller with i/o module, expandable to meet the io summary listed, the controllers shall be minimum 32 bit double microprocessor based standalone working on tcp/ip on bacnet ip with integral web browser, calender fundtion complete with day, month, week, year etc, real time clock & 1 second scan time. ddc working on 230v ac are preferred. the ddcs shall be capable of peer to peer communication without help of communication controller / router / system interface controller / pc and shall communicate with the building lan directly. these shall come with lockable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip step down transformer, mcb, internal wiring. (contractor shall confirm his i/o provision w.r.t requirement on basis of data point) on ahrae approved bacnet protocol only. ddcs shall work on either 230v power supply or shall contain ul listed smps in the panel job 6 supply installation testing, programming & and commissioning work for a music system including 2c x 1.5 sq.mm, twin parallel multi stranded copper armoured/unmanoured cable in 20 /25 mm diameter pvc conduit. with full range, a 6.5 inch woofer and a 1.25 inch coaxial tweeter mounted within the dispersion alignment system, delivering a frequency range of 59 hz – 20 khz. public address amplifier 1200w 120v /mk2 version should have required signal to noise ratio, wireless handheld microphone, 9u 19 rack for mounting of all amplifire and player, portable bluetooth pa system, wireless option and usb ., one year on site support. one time user training. system configuration, tuning. documentation. with all required accessories including all support work. job 7 supply installation testing & and commissioning work for projector installation with projection screen image brightness 6000 ansi lumens 7,150 iso lumens ,contrast ratio • full on/off 1300:1 • 3,000,000:1 technology type native resolution 1 chip 0.67dmd s600hb1920 x 1200 wuxga 16:10 aspect ratio illumination type high efficiency blue laser phosphorperformance 20,000 hrs to 50% brightnessinputs hdmi (1.4a) • hdmi 2.0 • hdbaset • 3d sync in (bnc) • vga • audio in (3.5mm phone jack) • usb a • ir recieveroutputs 3d sync out (bnc) • hdmi • audio out (3.5mm phone jack),warping and blending standardtaa compliant yes speakers 2 x 10wlens type • 1.25 2.0:1 (1.6x throw ratio) motorized lens powered zoom, focus and offset • 0.65 0.75:1 (1.1x zoom) motorized lens powered zoom, focus and offset lens offset • vertical +/ 110% • horizontal +/ 50% • vertical +/ 100%• horizontal +/ 30%displayable scanning frequency scan rates max pixel clock rates• horizontal: 15.375 91.146 khz • vertical: 24 85 hz (120hz for 3d feature) • 594 mhz (4096 x 2160); 162 mhz (1600 x 1200) accessories standard • power cable ,ir remote control (batteries included) optional • dust filter • wifi dongle • 3.5mm cable for wired remote functionality 8 power requirements operating voltage • ac 100 240v, 50/60hz power consumption • 500w • 660w operating current • 5a • 6.5aaudible noise • 25dba 30dba depending • 27dba 34dba depending • 27dba 36dba depending on the mode used on the mode used on the mode used enviroment temperature • 0 40°chumidity • 10 85% rh altitude • 0 2,500ft @ 0°c 40° c • 2,500 5,000ft @ 0°c 35°c • 5,000 10,000ft @ 0°c 30°c• conforms to all relevant european directives, standards, safety, health and environmental concerns rohs, reach, weeewarranty • 3 years parts and labor on the projector • 3 years or 20,000 hours parts and labor on the illumination system• reference the christie standard limited warranty document for details• or contact an authorized christie representative for full details of our limited warranty n) hvac system 1 sitc of basement ventilation and smoke extraction system comprises of axial type fans, jet fans, co sensors and plc panel. system will be operational in case of normal mode and fire mode as pe the nbc considering 6 / 12 acph. the system also needs to be intergrated with fire panel through a potential free contact. 1. ceiling suspended fresh air tube axial dual speed fan suitable as per specifications, 12000 cfm vs 20 mm static (normal mode) 24000 cfm vs 80 mm static (fire mode)2. ceiling suspended exhaust air tube axial dual speed fan, suitable for 250° c for 2 hrs. and as per specifications 12000 cfm vs 20 mm static (normal mode) 24000 cfm vs 80 mm static (fire mode)3. ceiling suspended ductless centrifugal type dual speed jet fan suitable for 250° c for 2 hrs. and as per specifications ø504 mm : 3275 cfm (normal mode) ø504 mm : 6550 cfm (fire mode)4. co transmitters, 0 50 ppm5. microprocessor panel / controller with control cabling for integration of co transmitters and jet fans6. factory fabricated g.i. fresh air duct with flanges, supports etc.as per approved shop drawings, specifications and smacna standards 22 gauge (0.81 mm thick) 24 gauge (0.63 mm thick)7. fresh air weather louvers with bird screen8. distribution panel with mounting arrangements, incoming and outgoing mccb / mcb, indication of voltage, current & power, phaseindicating lights, contactor / over load relay with built in single phase preventor, power factor improvement (lagging) close to unityand input signal from fire alarm system and suitable for :1no. fresh air fan, 1no. exhaust air fan, 3nos. jet fans, 3nos. co transmitters, controllers and spares9. power cabling & earthing as per specifications between panel andall equipment with hangers, supports, and trays etc.4 core 16 sqmm cu armoured frls cable4 core 10 sqmm cu armoured frls cable4 core 6 sqmm cu armoured frls cable4 core 2.5 sqmm cu armoured frls cable4 core 1 sqmm cu armoured shielded cable (area 3500 sqm) job 2 sitc of staircase & lobby pressurisation is proposed for the fire staircase and the respective lobby to allow safe rescue of occupants and access to the firefighters. the pressure levels are to be maintained as per the norms laid by nbc 50 pascals. the system should contain axial fans, grilles for air distribution, a pressure relief damper and a necessary electrical panel. this system will be operational only in case of fire thus the system should be looped with a fire fighting system through a potential free contact. (4 staircases & 2 lift lobbies) (42,000 cfm) job 3 sitc of liftwell pressurisation.this system is proposed to provide smoke free lift access for fire fighters for quick access to floors . axial fans and electrical panel considered with necessary accessories. this system will be operational only in case of fire thus the system should be looped with fire fighting system through a potential free contact (27,500 cfm for one liftwell) nos 4 sitc of the system which is an essential component in helping to maintain indoor air quality and improve comfort for occupants. the system requires a proper selection of fans with the necessary static pressure for all toilets with properly sized gi ducting and other air distribution products. the foul air will be pushed to the ambient through gi ducting installed in the plumbing shaft. the system will be efficiently designed to keep the toilets smell free (20,000 cfm , 1 working & 1 standby) for ducting length approx 60 meter. job 5 air conditioningsitc of vrv system with modulating outdoor units, with r410 a refrigerant, multi scroll compressors (all variable), special precoated fins, panel, corrosion resistant(suitable for seaside installation) coated condenser, inverter basedcondenser fan, m.s. hot dip galvanised stands / supports,electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units, andcompatible to operate in cooling mode at 42 deg c ambient conditions,with following minimum cooling capacities. with all necessary accesories & properly sized gi ducting, other air distribution products for uniform distrution of air and maintain a temperature of 24 degc in the premises. a entrance lobby 50tr b food court 190 tr per tr c lift lobby 100 tr per tr d banquet hall 110 tr per tr e gym 30tr per tr 6 supply, installation, testing and commissioning of modulating outdoor units, with r410 a refrigerant, multi scroll compressors (all variable), special precoated fins, panel, corrosion resistant(suitable for seaside installation) coated condenser, inverter basedcondenser fan, m.s. hot dip galvanised stands / supports, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units, andcompatible to operate in cooling mode at 42 deg c ambient conditions,with following minimum cooling capacities. all refrigerant (cu) piping along with fittings, hangers, trays and supports etc. between indoor & outdoor units duly class o insulatedfinished with glass cloth and lag coating as per specifications.gas piping with 19 mm nitrile rubber insulationliquid piping with 13 mm nitrile rubber insulationcommunication cabling between outdoor units and indoor units infrls pvc conduitms stands for odu unitspower cabling & earthing as per specifications between panel and all equipment with hangers, supports, and trays etc.14g perforated cable tray with cover 600mm x 100mm.(120 tr) per tr 7 sitc of the system is designed to remove smoke, heat, grease, and cooking odours generated during the cooking process in a kitchen. these systems are essential for maintaining a healthy and comfortable indoor environment with sisw exhaust fan with dry scrubber (optional), electrical panel, and also necessary ducting suitable to release the exhaust air outside the building on the same floor approx length 60 mtr. (10,000 cfm ) ...
39526432 provision of 1 x rmu 22 kv 630 amps alongwith vcb panel 11 kv with allied protection relay at new 22 kv / 11 kv sub station for mh kirkee under ge mh and rh khadki...
38896331 work of repairing, servicing ,testing of 11kv vcb panels at mahim pumping stations....
38215052 bids are invited for supply, installation, testing and commissioning of 11kv, 800a vcb panel (incomer cum outgoing) as pe (q3) total quantity : 2...
38073202 tender for supply, installation, testing & commissioning of 630 kva transformer & 11 kv ht vcb panel along with allied works at sant gadge maharaj chowk pumping station...
37962584 tender for augmentation of substation equipment at bkc mtnl mumbai servicing of 1 no. incomer and 2 nos. outgoing of vaccume circuit breaker type ht panel i / c megraing, check protection relay, ct, pt, tight every nut bolt of end termination, checking of circuit breaker mechanically closing & tripping, replacement of faulty bus bar insulator if required complete as required. 2 cleaning of ht panel inside sheet with sand paper and painting with one coat of primer and two coat of enamel paint. 3 sitc of three phase , 11 kvcast resincurrent transformer formetering purpose. current transformer of rating ( 200 / 100 / 5 / 5 ) for 11 kvht panel. ( note : 1 set will contains the 03 nos. of cts ) 4 sitc of three phase 11 kvcast resin potential transformer formetering purpose.potential transformer of rating ( 11kv / 110 volt ) for 11 kvht panel. ( note : 1 set will contains the 03 nos. of pts ) 5 repairing of faulty 11 kv vcb panel including replacement of all three number vacuum interrupters , mounting supports & three number insulators , cleaning carbon from all parts , testing ir value of insulators , spray ) .remove all damage parts .installing vacuum interrupter and mounting supports , insulators , repairer mechanism system & on / off operation complete as required. 6 sitc of following accessories in the existing 11 kv ht panel: 7 a ) ammeter digital typefor11 kv ht panel 8 b ) voltmeter digital type for 11 kv ht panel 9 supplying and making of ht cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core, xlpe aluminium conductor ( armoured ) cable of 11kv / 22kv grade i / c cutting, removing the existing faulty cable end termination wherever required etc. complete as required. ( note: make of jointing kit denson / raychem or equivalent ) indoor type joint. 10 servicing of 1250 kva dry type transformer i / c calibration, meggraing, cleaning, checking protection relay, complete is required....
37881564 supply, installation, testing and upgrade of pen stock gates electric equator, 11 kv ht vcb panel work...
37875239 tender for supply, installation, testing &commissioning of 630 kva transformer and11 kv ht vcb panels along with allied works at sant gadge maharaj chowk pumping station...
37486907 tender for design, manufacture, procure, supply, structure, erection and commissioning of 2000 kw ht slip ring motor with asr, vcb panel, capacitor and ht cable with panel...
37467051 replacement of vcb sprouts of 11kv abb make vcb panels of main hill substation of chikla mine => limited...
37049281 supply of set of spare for filter for dj/vcbset of spare for filter for dj/vcb,set of spare for filter for dj/vcb panel of siemag make model no.sb.ss.60.sh4 one set comprising of 7 items = 07 nos. as per drg.no. bsl/elw/sk no.9098. [ warranty period: 30 months after the date of delivery ]...
36960941 bids are invited for i ) supply, installation, testing and commissioning of 2 nos of indoor type 11kv, 800 a vcb panel with current transformers and metering for tapping power to hip substation ii ) supply, installation, testing and commissioning of 5 nos of indoor type 11 kv, 800 a vcb panel with current transformers, potential transformers and metering to receive power to hip substation supply, installation, testing and commissioning of 2 nos of outdoor type 2500 kva, 11 kv, / 433 v, onan transformer with oltc, rtcc, avr etc iv ) supply, laying, testing and commissioning of ht 11 kv cable and ht 11 kv straight through and end termination joints etc v ) supply, installation, testing and commissioning of 415 v lt main power panels, lighting panel in substation. vi ) supply, installation, testing and commissioning of 415 v automatic power factor correction panel ( apfc ) of rating 1250 kvar in substation. vii ) supply, laying, testing and commissioning of lt power & control cables, terminations of cables etc viii ) supply, installation, testing and commissioning of safe earth electrode earthing system ( gi coated and copper coated ) and earthing strips. ix ) supply, installation, testing and commissioning of diesel generator set of rating 25 kva 3 phase, 415 volts, 50 hz complete with automatic mains failure ( amf ) panel for staring on mains failure with meters and sound proof canopy as per cpcb norms, with foundation and other associated civil works complete. supply, laying, testing and commissioning of battery charger panel and battery. xi ) obtaining approval for charging of the substation from central electricity authority ( cea ) ...
36434142 bids are invited for procurement of vcb panels a panel of 6 vcbs, 11kv, 150mva , 400a, nflp indoor type distribution board panel , a panel of 6 vcbs, 11kv, 150mva , 400a, nflp indoor type distribution board panel , a panel of 13 vcbs, 3.3kv, 75mva , 1250a, nflp indoor type switch board panel , a panel of 14 vcbs, 11kv, 75mva , 1250a, nflp indoor type switch board panel , a panel of 6 vcbs, 3.3kv, 75mva, 1250a, nflp indoor type switch board panel , a panel of 19 vcbs, 3.3kv, 75mva, 400a, flp indoor type switch board panel , a panel of 3 vcbs, 3.3kv, 75mva, 400a, nflp indoor type switch board panel , a panel of 3 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board , a panel of 4 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board , a panel of 5 vcbs, 3.3kv, 75mva, 400a, flp indoor type power distribution board total quantity : 13...
35883464 work of repairing, servicing ,testing of 11kv vcb panels at wadala pumping stations...
35743293 manufacturer of vcb panel /switchgear, wireless temperature sensors....
35666735 replacing of existing old ht bocb panel with ht vcb panel 11kv 630 amps rmu extensible type outdoor/ indoor scada compatible motorized unit in substation and other allied works at nehru science centre mumbai...
35628583 tender for special repair to 22 kv main icog vcb panel with connected accessories and provisioning of cabling and associated fitting and panels for stand by power supply augmentation to inhs kasturi at ins shivaji lonavla...
35574804 supply, installation and commissioning of 11 kv vcb panels, transformers, 11 kv cable, lt panels and other electrical accessories for the hot isostatic press ( hip ) facilities at hal, nasik...
35549703 tender for repair maintenance to ht equipments for shore supply at various cassions and jetties at naval dockyard under ge nw kunjali colaba mumbai supplying , laying, jointing testing and commissioning of ht ug cable, xlpe insulated, screened insulated, armoured and pvc bedded, 11000 volts grade ( heavy duty ) suitable for earthed system with aluminium conductor of size 3 core 240 sq.mm conforming to is 7098 part ii laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cable complete all as specified and directed by engineer in charge. 2 supplying , laying, jointing testing and commissioning of ht ug cable, xlpe insulated, screened insulated, armoured and pvc bedded, 11000 volts grade ( heavy duty ) suitable for earthed system with aluminium conductor of size 3 core 185 sq.mm conforming to is 7098 part ii laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cablecomplete all as specified and directed by engineer in charge . 3 material and labour cable end termination box, heat shrinkable, indoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any description complete all as specified and directed by engineer in charge. 4 material and labour cable end termination box, heat shrinkable, indoor type suitable for 6.6 11kv, 120 to 185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any description complete all as specified and directed by engineer in charge. 5 material and labour cable end termination box, heat shrinkable, outdoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 6 material and labour cable end termination box, heat shrinkable, outdoor type suitable for 6.6 11kv, 120 to 185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 7 material and labour straight through joint , heat shrinkable, outdoor type suitable for 6.6 11kv, 50 to95sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 8 material and labour straight through joint , heat shrinkable, outdoor type suitable for 6.6 11kv, 120 to185sq.mm xlpe, 3 core power cable with aluminium conductor including dismantling old cable end termination of any descriptioncomplete all as specified and directed by engineer in charge. 9 note for item no. 1 to 8: above quoted rates deemed to be included for fault finding manually or by machine and repairing it within 12 hrs. 10 material and labour for ( i ) disconnecting the ht / lt side and earthing connections of the transformer, ( ii ) lifting transformer with the help of crane, loading on suitable vehicle to transport it to the workshop and unloading at workshop for servicing ( iii ) dismantling of hv / lv bushing, opening of top cover, disconnecting of connections of tap changer of transformer ( iv ) draining out the complete transformer oil ( v ) lifting up the core and winding assembly ( vi ) washing and cleaning the core, rewinding of all burnout, damaged coils of core and phase, transformer tank and radiator fins with help of pressurized transformer oil for removal of sludge and sludge deposit so as to make them free from dust, dirt and sludge deposit ( vi ) heating and ovening of core and winding assembly complete in vacuum chamber for 72 hours so as to remove any moisture content in the core / winding and attaining requisiteir value, ( vii ) retanking of complete core & winding assembly & fixing tap changer after servicing and testing, ( viii ) refixing hv / lv bushing and making all internal connections, ( ix ) providing new gasket packing minimum 12mm thick, including nut bolt washer complete, ( x ) transporting transformer back to the site , lifting it down with the help of crane and reconnectingthe ht / lt cable and earthing connections complete all as specified and directed by engineer in charge. of followings capacities: 11 500 to 630 kva, 6.6 11kv / 433v 12 631 to 1000kva, 6.6 11kv / 433v 13 1001 to 1600kva, 6.6 11kv / 433v 14 1601 to 2500kva, 6.6 11kv / 433v 15 note for item no 9.00 : ( i ) in case of damage during transport / loading / unloading at any stage after receipt of transformer from department, the contracor shall be repsonsible for damage and it shall be made good by him at his for expense.the decision of engineer in charge in the regards shall be fixed & binding ( ii ) transformer oil required for filling shall be measured and paid seperately ( iii ) all other spares required shall be measured and paid sperately ( iv ) rates are inclusive of testing of earthing before connection of transformer 16 material and labour for shifting transformer upto 2500 kva, 6.6 11kv / 433v, from location inside dockyardand connecting ht / lt side to provide temporary supply during repair of transformer and disconnectinght / lt connections before installations of repaired transformer location within naval dockyard complete all as specified and directed by engineer in charge. 17 material and labour in repairs hv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for 500 to 1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step up of any make / model complete all as specified and directed by engineer in charge. 18 material and labour in repairs hv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for above1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step upof any make / model complete all as directed 19 material and labour in repairs lv side brass studs threaded both ends of suitable size and length including metal and rubber rings, . bolts washer, etc. suitable for 500 to 1600 kva transformer ( indoor or outdoor type ) , 6.6 11kv / 433v, step down / step up, of any make / model complete all as specified and directed by engineer in charge. 20 material and labourin repairs lv side brass studs threaded both ends of suitable size and length including metal and rubber rings, bolts washer, etc. suitable for above1600 kva to 2500 kva transformer and above outdoor type, 6.6 11kv / 433v step down / step up ) of any make / model complete all as specified and directed by engineer in charge. 21 supply and fixing in repairs hv / lv side porcelain bushing / insulator of suitable size suitable upto2500kva transformer, outdoor type, 6.6 11kv / 433v , step down / step up, of any make / model complete all as specified and directed by engineer in charge. 22 supply and fixing in repairs hv / lv side porcelain bushing / insulator of suitable size suitable for above 500kva transformer, outdoor type, 6.6 11kv / 433v , step down / step up, of any make / model complete all as specified and directed by engineer in charge. 23 supply and fixing in repairs silica gel container with first fill of silica gel transparent type suitable for transformer of capacity 500 kva to 1250 kva complete all as specified and directed by engineer in charge. 24 supply and fixing in repairs silica gel container with first fill of silica gel transparent type suitable for transformer of capacity above 1250 kva to 2500 kva complete all as specified and directed by engineer in charge. 25 testing of di electric strength of transformer oil of transformer indoor / outdoor type, 6.6kv / 433 volts, before filteration and to remove moisture and impurities and to improve di electric strength above 48 kv / minute through filtration plant incl filling of new transformer oil for topping up, testing complete all as specified and directed by engineer in charge. filtration of transformer oil by electrically operated transformer oil filtration plant to achieve a test result of 48 kv / min for distribution transformer and 80 kv / minute for power transformer for 2.5 mm gap. ( note: testing machine and transformer oil filtration plant as well as dehydration facility will be provided by the contractor .ii ) new transformer oil shall be measured and paid separatelly under respective items ) . 26 supply only transformer oil as per is 335 / 93 dehydrated to give bdv value not less than 50 kv when tested with 2.5mm gap electrode complete all as specified and directed by engineer in charge. 27 supply only silica gel in air tight container suitable for dehydrating breathers of transformers complete all as specified and directed by engineer in charge. 28 material and labour for replacement of the following for 500 kva to 2500 kva, 6.6 / 6.6 11kv / 433v transformer: 29 oil level indicator 30 tap changer 31 dial type 100mm dia oil temp meter 32 air release plug assembly 33 drain plug 34 gun metal oil drain valve 25mm / 40mm 35 material and labour for spraying painting to indoor / outdoor type, step up / step down / step up transformer 6.6 / 6.6 11kv / 433 v installed at different locations of nd area after scraping thoroughly the existing corroded paint / rust, filling of cavities and applying one coat of silicon acrylic heat resistant paint of approved quality of approved colour and writing the details such as, sm / mes no. etc. complete all as specified and directed by engineer in charge for following capacity. 36 500to 630 kva 37 631 to 1000kva 38 1001 to1600kva 39 1601 to2500kva 40 material and labour for pcc 1:4:8 type d2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified and directed by engineer in charge. 41 material and labour for pcc 1:3:6 type c2 using 40 mm graded aggregate in foundation, filling and mass concrete complete all as specified and directed by engineer in charge. 42 supply and fixing acb 2500a, edo type 4 pole , retrofit type , designed as per exisitng lt panel complete all as specified and directed by engineer in charge. 43 material and labour of the pvc board of appropriate size and thickness duly pasted with computerised letter mentioning no smoking , danger 11000 volts with skull and cross painted, no admission except on duty, sm / mes no. for the transformer / ht breakers / dg setsincluding accessories etcfor the substations including accessories for properly fixing the same on wall / fencing / pole complete all as specified and directed by engineer in charge. 44 material and labour trench / duct cover, light weight, anti corrosive, with frp pultruded section to meet specific load application of cable pit covering complete all as specified and directed by engineer in charge. 45 material and labour for fixing standard shock treatment chart in english & hindi duly framed and covered with glass complete all as specified and directed by engineer in charge. 46 supply , fixing, testing in repairsof jef eco safe maintenance free grounding solution set comprising of high tensile low carbon steel rod of 3 mts length & 25 mm dia with 250 micron ( averaschneider ) molecularly bonded copper on the outer surface to confirm with requirements of ul467 along with back fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 ohm mtr as per clause 14.5d of ieee : 80 standard. back fill compound should be electronically conductive ( like in metals ) and should not depend on moisture for conduction. jef powerfill loresco compound shall be supplied in 50 pound bag. ( 1 bag of 50 pounds required per earthing set ) . back fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. a suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl complete all as specified and directed by engineer in charge.note : back fill compound shall not be mixed with any soil while pouring in the bore hole. 47 supply fixing, testing in repairs of jef eco safe maintenance free grounding solution set comprising of high tensile low carbon steel rod of 3 mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of ul467 along with back fill compound strictly be a carbon based conductive concrete type which has a resistivity of less than 0.12 ohm mtr as per clause 14.5d of ieee : 80 standard. back fill compound should be electronically conductive ( like in metals ) and should not depend on moisture for conduction. jef eco safe compound shall be supplied in 50 pound bag. ( 1 bag required per earthing set ) . back fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. a suitable earth terminaton clamp should also be suppliednote : back fill compound shall not be mixed with any soil while pouring in the bore hole. 48 supply and fixing for repair of earth continuity conductor or main earthing lead of following size of galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduct / pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and directed by engineer in charge. 49 32x6mm 50 25x4mm 51 material and labour for preparation of oldsurfaces of transformer foundation and applying two coat of cement based paint on it, all as specified and as directed by engineer in charge 52 supply and fixing in repairs 6.6 11 kv single phase current transformer ( cts ) conforming to is 2075, va burden 1va, class of accuracy 0.5 / 5p 10 / ps, type of ct as per existing with ctr 40 20 / 5a / 5a / 100 50 / 5a / 5a complete all as specified and directed by engineer in charge. 53 material and labour for test point terminal block made out of gun metal or phosphorus bronze size 75 x 25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws to be fixed on steel structure with drilling / tappingandclamping etc complete all as specified and directed by engineer in charge. 54 material and labour galvanised pipe including fittings, light grade fixed to poles, on walls laid under road in trenches for protection of underground cable complete all as specified and directed by engineer in charge of 100mm dia. 55 provision of cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with the existing surfaces with pcc 1:3:6 type c2, complete all as specified and as directed by engineer in charge. 56 supply and fixing insulation mat as per is15652:2006, having not less than 30kv dielectric strength and having insulation resistance of not less than 1mohm, acid retardant, flame retardant with auto glow band, having width of 1.0mtr and length upto 2.0 mtr, of thickness not less than 2.50 mm.complete all as specified and directed by engineer in charge. 57 supply and fixing in repairled lamps of existing lt panel board and supply and fixing new led lamp including making necessary electrical connection all as specified and directed by engineer in charge. 58 supply and fixing cost effective, durable and reliable 6.6 11 kv heat shrinkable anti tracking bus bar tubing sleeve of dia 50mm, for bus bar of vcbs, flame retardant and protetcion againstmoisture, dust including all accessories complete all as specified and directed by engineer in charge.of make jointmask 1133 series. 59 supply and fixing in repairs 11 / 6.6 kv potenialtransformer ( pts ) as per existing size and make suitable for ht vcb panel of incuding taking down old unserviceable ptscomplete all as specified and directed by engineer in charge. 60 supply and fixing in repairs 11 / 6.6 kv spout as incomer [ ryb ] one set and outgoing [ ryb ] oneset as per existing size and make suitable for ht vcb panel incuding taking down old unserviceable spout set complete all as specified and directed by engineer in charge....
35292756 supply installation and commissioning of vcb panel at hariyala lpg plant...
35170964 repairing of sub station equipment at t.e building kandivali mtnl mumbai. as per nit repairing of faulty 11 kv vcb including dismantle vacuum interrupters, mounting supports & insulators. cleaning carbon from all parts, testing ir value of insulators. vacuum interrupters & supports including. apply high voltage test. reinstalling vacuum interrupter and mounting supports, insulator, testing ir value & on / off operation, electrical and mechanical spring charging system repair, including repairing and calibration of mechanical spring charging gearbox, repair of 2 nos frp supporter set, repairing of 2 nos frp spring set, repairing of 2 nos supporter insulator megraing, including loading / unloading & transportation to work shop if required complete as required. 1 job 2 repairing of vacuum interrupter in 11 kv vcb panel i / c testing, meggering complete as required. 3 job 3 repairing, servicing & lubrication of acb of all ratings i / c all components, repair mechanism system etc complete as required. 1 job 4 sitc of following rating fn type tpn sfu with operating handle in the existing above panel i / c interconnection etc. complete as reqd. a ) 100 amp 1 no 5 servicing / checking and removing of oil leakage in 1250 kva oil type transformer i / c disconnection of ht and lt side cable & bus bar, remove complete oil and store in drum, and lift transformer if required with the help of chain pulley, specialized labour, i / c changing transformer gasket and transformer body butterfly radiator leakage attend, oil remove and oil top up, reconnection ht and lt side etc complete as required....
34381194 bids are invited for supply, installation, testing and commissioning of 11kv, 800a vcb panel (incomer cum outgoing) as pe(q3) total quantity : 2...
33885667 repair / maintenance of high tension distribution system and ht equipments at kanheri hills and hill top at site k hills site r and site p under ge airforce thane m&l for calibration all measuring meter with, servecing all mechanical parts, replace the all electric wiring of panel, decarbonizing all ht contact point testinght 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampsincluding replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmete , vaf meter, selector switch all illuminated indicationes for r, y, b, pahse, by qualified technical person from oem, complete all as specified and directed by engr in charge.note: necessary spare parts, need to replace will be paid in respective item. 2 m&l for calibration all measuring meter with, servicing all mechanical parts, replace the all electric wiring of panel, decarburizing all ht contact point testinght 11kv vertical draw out type vcb of rupturing capacity 250 mva, 250 ampsincluding replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vacuum of interrupter, including connected accessories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmeter , vaf meter, selector switch all illuminated indications for r y b phase, including high voltage test, primary injection test, relay testingby qualified technical person from oem, complete all as specified and directed by engr in charge.note: ( a ) necessary spare parts, need to replace will be paid in respective item ) 3 m&l for indicator led lamp, red, yellow and orange 110 v, ac, for ht 22 kv vcbcomplete all as specified and directed by engr in charge. 4 supply closing coil, 110 v, dc for servicing / repairing the ht 22 kv vcb complete all as specified and directed by engr in charge. 5 supply shunt release coil on, 110 v, dc, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 6 supply shunt release off, 110 v , dc, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 7 supplycontrol fuse, hrc, 2 / 4 / 6 amp for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 8 supply motor cut off switch for servicing / repairing the ht 22 kv vcbcomplete all as specified and as directed by the engr in charge. 9 supply ht tape for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 10 supplymonoplast tape for servicing / repairing the ht 22 kv vcbcomplete all as specified and as directed by the engr in charge 11 supply digital volt meter 96x96mm, 0 500v, aux supply 110v, ac, suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 12 supply digital ammetersuitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 13 supply auxiliary switch on block magnet for servicing / repairing the ht 22kv vcb complete all as specified and as directed by the engr in charge. 14 supply male & female spout assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 15 supplyct of ratio 50 / 5 a for vcb suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 16 supplyover current really suitablefor servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 17 supply master trip relay suitable for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 18 supply digital vaf meter , em 6400suitable for ht 22 kv vcb for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge. 19 supply contact arm assembly for ht 22 kv vcb for servicing / repairing the ht 22 kv vcb complete all as specified and as directed by the engr in charge 20 supply closing coil, 110v, dc for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 21 supply shunt release on, 110v, dc for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 22 supply shunt release off, 110v, dcfor servecing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 23 supply motor cut off switch for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 24 supply auxiliary switch on block magnetfor servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 25 supply male & female spout assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 26 supply ct of ratio 30 / 5 a for vcbfor servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 27 supply relay assembly ( current, voltage ) suitable for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 28 supply master trip relay suitable for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 29 supply contact arm assembly for servicing / repairing the ht 11 kv vcb complete all as specified and as directed by the engr in charge. 30 m&l forservicing / testingofpower transformer11 / 22 / 0.44 kv up to capacity 400kva ( a ) ir value of winding. ( b ) de carbonizing the cable terminal of the transformer. ( c ) earth resistance checking. ( d ) replacement of silica gel 31 dehydration / filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 35 to 40 kv at 2.5 mm gap in existing position of transformer / servo stabilizer of any capacity and transformer oil for topping up at various sub station complete all as specifiedand directed by engg in chargenote: transformer oil used for top up measured and paid separately. 32 supply and pouringof new transformer oil to achieve a di electric strength up to 60 kv in 4 mm gap conform to is 335 1983 with sealed barrel contains each 210 litre 33 disconnection the ht termination, supply and fixing ht boot cover at cable end and vcb / rmu complete all as specifiedand directed by engg in charge 34 disconnecting all in coming and outgoing cables, removing the transformer / servo stabilizer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractors workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable sizetaping thebushes / bus bars, using insulation tape and testing completeof capacity 160 kva to 400 kva all as directed .note: gasket set, lt / ht side ceramic bushing, spindle for ht / lt side , rewinding, dehydration of oil shall be measured and paid separately in respective items. 35 m&l for taking out unserviceable winding & supply and winding of22 / 0.433 kv hv coils, using new copper wire / strip of proper size including insulating materials ( double insulation ) as per existingsize of core of transformer capacity 160 400 kva complete including heating , varnishing complete all as specifiedand directed by engg in charge 36 m&l for taking out unserviceable winding supply and winding of22 / 0.433 kv lv coils, using new copper wire / strip of proper size including insulating materials ( double insulation ) as per existingsize of core of transformer complete incl heating , varnishing complete all as specifiedand directed by engg in charge 37 supply only breather assembly of approved make filled with silica gel suitable for transformer ofcapacityupto 400 kva volt distribution transformer complete all as specifiedand directed by engg in charge 38 supply only brass spindle for terminal on ht side threaded complete with nut washers etc of suitable dia for transformer of capacity 160 to 400 kva complete all as specifiedand directed by engg in charge 39 supply only brass spindle for terminal on lt side threaded complete with nut, washers etc of suitable dia for transformer ofcapaicty 160 to 400 kva complete all as specifiedand directed by engg in charge 40 supply and fix ceramic bushing and gasket on lt side of transformer of capacity 160 to 400 kva 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 41 s & fceramic hv bushing with gun metal bushing stud, nuts and washers for transformerof capacities 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 42 supply and fixing in replacement of complete gasket ( cork sheet ) 6 mm thick complete of capacity of 160 kva to 250 kvatransformer including conical rubber bush complete all as specifiedand directed by engg in charge 43 disconnecting all incoming and outgoingconnection of ht11 / 22 kv underground cable, detecting faultby applying surge current 1.5 times the rated current& finding exact location of fault with picco equipmentand repair the same immediately all as directed. note: ( a ) necessary jointing kit to be measure and paid cables. complete all as specifiedand directed by engg in charge 44 supplying, jointing and commissioningoutdoor type cable end termination jointing kit heat shrinkable type suitable for underground xlpe cable size 3 core 95 to 120 sqmm 11 / 22 kv ht cablecomplete all as specifiedand directed by engg in charge 45 supplying, jointing and commissioningindoor type cable end termination jointing kit heat shrinkable type suitable for under ground xlpe cable size 3 core 95 to 120 sqmm 11 / 22 kv ht cable complete all as specifiedand directed by engg in charge 46 supplying, jointing and commissioningstraight through type cable end termination jointing kit heat shrinkable type suitable for underground xlpe cable size 3 core 95 sqmm 11 / 22 kv ht cable complete all as specifiedand directed by engg in charge . 47 taking up unserviceable ht 22 kv underground cable for repair, replace the damage portion complete all as specifiedand directed by engg in charge 48 supply and laying, testing and commissioningh.t. under ground armored pvc insulated and pvc sheathed heavy duty 22000 volts grade underground cable of size 3 core, 95 sq mm complete all as specifiedand directed by engg in charge 49 supply and laying, testing and commissioningh.t. under ground armored pvc insulated and pvc sheathed heavy duty 11000 volts grade underground cable of size 3 core, 120 sq mm complete all as specifiedand directed by engg in charge 50 relaying the serviceable ht cable, after necessary testing in ground, floor in same trench ornew route complete all as specifiedand directed by engg in charge 51 supply and fix gi pipe 100 mm dia light grade complete with all fitting for supporting cable on four pole structure complete all as specifiedand directed by engg in charge 52 excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out / laying cable and getting out in hard / dense soil complete all as specifiedand directed by engg in charge 53 removing excavation soil at a distance not exc 50 m and deposited where diverted complete all as specifiedand directed by engg in charge 54 returning, filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as specifiedand directed by engg in charge 55 sand cushioningfor cable protection by spreading in trenches crushed stone sand by gently punning down manually complete all as specifiedand directed by engg in charge.note: punnned thickness shall only be measured and paid. 56 supply and laying un reinforced precast concrete cable cover class ehv, type i, flat size 300 mmx 180 mm x 40 mm laid in trenches complete all as specifiedand directed by engg in charge. 57 re laying un reinforced precast concrete cable cover class ht, type i, flat size 300 mmx 180 mm x 40 mm laid in trenches complete all as specifiedand directed by engg in charge. 58 supply and cross arm, bracing, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding, bending, drillingholes for bolts in any shape and any size inclusive of one primer coat, two coats of aluminium paints as indicateed complete all as specified and as directed by engineer in charge 59 dismelting the unserviceable broken gi strip of any size as available at site, supply and fixing cupper strip of size 32x6mm for connection from ht equiptment to earth pit . ( necessery connection to be made through brezing and brass nuts and bolt ) complete all as specifiedand directed by engg in charge 60 m&l for shutter assembly suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 ampscomplete with mechanism complete all as specifiedand directed by engg in charge 61 m&l for pt 22 kv / 110vsuitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps for metering purpose complete all as specifiedand directed by engg in charge 62 m&l for breaker bus bar arm long with female contact suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps complete all as specifiedand directed by engg in charge 63 m&l for pp tubes suitable forht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps along with necessary accessories complete all as specifiedand directed by engg in charge 64 m&l for phase barrier along with necessary accessories suitable for ht 22kv vertical draw out type vcb of rupturing capacity 250 mva, 250 amps complete all as specifiedand directed by engg in charge 65 m&l for heater and thermostat suitable for ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 66 m&l for bushing spout panel ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 67 m&l for tnc switch suitable for ht 22kv vertical draw out type vcb of repturing capacity 250 mva, 250 ampscomplete all as specifiedand directed by engg in charge 68 s&f in replacement single phase smps based battery backed power pack for supply back up for trip coil, protection relay, indication, & other load in ht panels, working input voltage 90 to 300 volt ac, output 110 volts dc with backup for 15 20 min, complete all as specifiedand directed by engg in charge 69 m&l for painting of transformer foundation with two coats of obd after complete scrapping of old paint / whitewash and making good surface complete all as specifiedand directed by engg in charge 70 m&l for ht 22 kv sleeve for repairing vcb 22 kv complete all as specifiedand directed by engg in charge 71 m&l for end terminal cable jointing kit for 22 kv ( earthed ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specifiedand directed by engg in charge 72 m&l for end terminal cable jointing kit for 22 kv ( earthed ) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specifiedand directed by engg in charge 73 m&l for cable jointing kit for 22 kv ( earthed ) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. 74 dehydration and filtration of transformer oil filled in transformer installed at different locations, testing of oil after dehydration to achieve dielectric strength not less than 40 kv for 1 minute in 2.5 mm electrode gap as per relevant is and to bring the acidity with the permissible limit complete all as specifiedand directed by engg in charge 75 supply & fixing in replacement of ceramic hv bushing with gun metal bushing stud, nuts and washers for transformerof capacities 165 / 250 kva complete all as specifiedand directed by engg in charge 76 supply & fixing in replacement of ceramic lv bushing with bushing stud ( brass metal ) , nuts and washers for transformerofcapacities 165 / 250 kva complete all as specifiedand directed by engg in charge 77 supply and filling fresh tansformer oil confiming to is 335 having die electric strenght up to 50 kv with oil testing kit 2 mm thick top up transformercomplete all as specified and as directed by engr in charge. 78 disconnecting of incoming & outgoing cable from both side of transformer indoor / outdoor type including all accessories, loading unloading and transportation from site to work shop as per site requirement and back to site after carried out repairs & assembling , including connection for the capacity 160 kva to 250 kva and commissioning and testing complete all as specified and directed by engr in charge.note: gasket set, lt / ht side ceramic bushing, spindle for ht / lt side, rewinding , dehydration of oil shall be measured and paid separately in respective items. 79 taking out defective ht winding and m& l for rewinding of ht coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 kva complete all as specified and directed by engr in charge. 80 m& l for rewinding of lt coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 kva complete all as specified and directed by engr in charge. 81 assembling of hv and lv coils including necessaryinsulation with paperboards and varnishing, making internal connections, drying, removal of moisture from core and coils, heating the complete and carried out all necessary tests for transformer capacity 160 kva to 250 kva complete all as specified and directed by engr in charge. 82 m& l for improvement of insulation resistance value for core & coil winding by cleaning complete, applying varnishing & necessary insulation material and baking in oven terminal connection inside the transformer complete all as specified and directed by engr in charge. 83 disconnecting the ht termination, supply and fixing ht boot cover at cable end and vcb complete all as specifiedand directed by engg in charge 84 disconnecting all incoming and outgoing connection of ht 22kv under ground cable, detecting fault by applying surge current 1.5 times the rated current & finding exact location of fault with pico equipment and repair the same immediately complete all as specified and as directed by the eng.in.charge.note: necessary jointing kit to be measured and paid separately in respective items. 85 m&l for servicing / testing the following equipment of distribution transformer 22 / 0.44kv: ( a ) ir value of winding ( b ) de carbonizing all cable connection. ( c ) earth resistance checking ( d ) replacement of silica gel complete all as specifiedand directed by engg in charge 86 painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove oil stains, dust etc and applying one coat of synthetic enamel paint by spray paint incl writing sm no. / mes no. of capacity 160 / 250 kva transformer completeall as specified and directed by eng.in.charge. 87 supply onlyassembly of approved make filled with silica gel suitable for transformer of capacity 160 / 250 kvadistribution transformer complete all as specified and as directed by eng.in.charge. 88 supply and fix brass spindle for terminal on ht side threaded complete with nut, washer etc of suitable dia for transformer of capacity 160kva to 250kva complete all as specified and directed by engg.in.charge. 89 supply and fix brass spindle for terminal on lt side threaded complete with nut, washer etc of suitable dia for transformer of capacity 160kva to 250kva complete all as specified and directed by engg.in.charge. 90 supply and fix ceramic bushing and gasket on lt side of transformer of capacity 160 to 250 kva 22000 / 433 volt distribution transformer complete all as specifiedand directed by engg in charge 91 supply and fixing in replacement of complete gasket ( cork sheet ) 6mm thick with and incl conical rubber bush complete all as specifiedand directed by engg in charge 92 m&l forservicing / testinght 22kv vcb panel rupturing capacity 26 / 3 mva, 1250 amps including calibration, decarburizing , troubleshooting, repairing, replacement of unserviceable spare parts and adjustment of over current relay, earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning offixed and moving contacts, testing of electrical wiring system, ammeter, voltmeter , vaf meter, selector switch all illuminated indications for r y b phase, by qualified technical personcomplete all as specified and by the engr in charge.note: necessary spare parts, need to replace will be paid in respective item. 93 supply only voltage indicator lamp ( red, yellow and orange ) 220 v, ac for servecing / replacement the ht 22kv vcb complete all as specified and directed by engg.in.charge. 94 supply only control fuse, hrc, 2 / 4 / 6 amp for servecing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 95 supply only ht tape for servecing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge 96 supply only monoplast tape for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 97 supply only high voltageover current protection relay for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 98 supply only earth fault relay for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 99 supply only auxillary contacts for servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 100 supply only space heater alongwith thermostat for ht vcb panel including electric connection complete all as specified and directed by engg.in.charge. 101 supply only master trip relay suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 102 supply only contact arm suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 103 supply only shunt release coil on, 110 v, dc suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 104 supply only shunt release coil off, 110 v, dc suitable for ht 22 kv vcb panel complete all as specified and directed by engineer in chrage. 105 supply only key locksfor servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 106 supply only switch operating assembly servicing / repairing the ht 22kv vcbcomplete all as specified and directed by engg.in.charge. 107 m&l for shutter assembly suitable for ht 22 kv vertical draw type vcb complete all as specified and directed by engr in charge. 108 m&l for taking down carefully existing serviceable switch air break, gang operated outdoor, any type of capacity upto 22 kv, servicing to the operating mechanism, greasing etc of all joints for smooth operation, with & including replacement of burnt male / female contact where required, re fixing the switch air break, gang operated outdoor, testing, complete all as specified and as directed. 109 taking down unserviceable god of any capacity and supply and installation ht 22kv / 200amps outdoor type god including dropout fuse assembly complete all required at site etc complete all as specifed and directed by engineer in charge. 110 supply & fixing dropout fuse 23 swgcomplete all as specified and directed by engg.in.charge. 111 s&f in replacement copper stripof size 32x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by engg.in.charge 112 s&f copper stripof size 20x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by engg.in.charge 113 s&f in replacement single phase smps based battery backed power pack for supply back up for trip coil, protection relay, indication, & other load in ht panels, working input voltage 90 to 300 volt ac, output 110 volts dc with backup for 15 20 min, complete all as specifiedand directed by engg in charge 114 s&f lightning arresters ht 22 kv 65 kilo amp non linear expulsion type transmission class with standard fittings confirming to is 3070 ( part i ) 1985, including dismantling & taking down old unserviceable lightning arresters, complete all as specifiedand directed by engg in charge 115 s&f disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 22000 volts, including dismantling & taking down old unserviceable insulator, complete all as specifiedand directed by engg in charge 116 supply & laying xlpe insulated , screened, pvc bedded, galvanizedsteel strip or wire armoured heavy duty electric power cable with aluminum conductor, 22000 v grade, cross sectional area of3 core 95 sqmm in trenchescomplete all as specifiedand directed by engg in charge 117 supply & laying un reinforced precast cement concrete cable cover class hv type 1, flat, size 300mm x 180mm x 40mm complete all as specifiedand directed by engg in charge 118 m&l for earthing complete with copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper strip of size 20x3 mm all as specified and shown in electric plate no 3 of mes ssr part i 2009 including earthwork, pcc chamber, ci cover, protection and watering pipe, funnel, mesh etc all as required at site and complete all as specifiedand directed by engg in charge.note: ( i ) . 7.5 rm copper strip in deemed to be included in quoted rates beyond 7.5 rm strip shall be measured and paid separately. ( ii ) . earth resistance of earth pit should be less than 2 ohms. on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. ( iii ) rate quoted by the tenderer is deemed to include salt & charcoal upto & above 450 mm top of copper plate. ( iv ) soil registance test if required shall be the responsbility of contractor without any extra cost. 119 excavation in trenches , n exc 1.5 m wide and n, exc 1.5 m in depth for foundation, etc. or for shafts, wells cesspits, manholes, peir holes. etc 1.5 m n exc 10 sqm on plan and n exc, 1.5 m in depth and getting outcomplete all as specifiedand directed by engg in charge 120 returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft / soil complete all as specifiedand directed by engg in charge 121 removing excavated soil not exc 50m depositing where directed at a level not exc 1.5m above the starting point complete all as specifiedand directed by engg in charge 122 m&l sand cushioning for ug cable protection / ducts, consolidated sand compacted with clean dry sand complete all as specifiedand directed by engg in charge 123 boringfor road crossingin any kind ofsoil / rock strata complete all as specifiedand directed by engg in charge 124 supply & laying gi pipe light graded of size 50mm diain trenches and fixing on wall / poleswith help of suitable size ms clamp for cable protectioncomplete all as specifiedand directed by engg in charge 125 supply & laying gi pipe light graded of size 80mm diain trenches and fixing on wall / poleswith help of suitable size ms clamp for cable protection complete all as specifiedand directed by engg in charge 126 supply, fixing & stretcing aluminium conductor steel reinforced ( acsr ) of any type and size fixedon existing steel tubular / pcc ht / lt pole fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by engineer in charge. notes : i ) the acsr conductors shall be conforming to is 398 ( part ii ) and as specified in ssrpart i .ii ) the unit rate quoted shall alsobe deemed to include for supply and fixing of binding wire, aluminium tapes etc which shall not be included in the weight of conductors for payment.iii ) weight of conductors shall be determined by measuring the horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size multiplied by lenght of span and 3 % extra shall be added for sag, jointing, jumpers etc.iv ) weight of the conductors shall be calculated from the nominal weights given in tables in the relevant is. 127 m&l for painting of transformer foundation with two coats of obd after complete scrapping of old paint / whitewash and making good surface complete all as specifiedand directed by engg in charge 128 m&l cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape inclusive of one primer coat, one under coat and one finishing coat of paint complete all as spd and directed by engg.in.charge. 129 m&l for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of gi and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateno. 5 of ssr part i of 2009 & as specified or indicated and testing on completion including exaction / earth work in any type of strata pcc ( 1:3:6 ) type c1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1:2:4 ) type b1 ( reinforced with welded steel wire fabric ( xpm ) weight not less than 4 kg / sqm ) , funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 25x4 mm with gi protection pipe of 20 mm medium grade 7.5 meter long, etccomplete all as specified and as directed by engr in charge.note: ( i ) venders are bound to get earthing result upto 5 ohm for single earthings and 3 ohm with the grid of two earthing.any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by contractor. ( ii ) excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. ( iii ) refill the pit with m&l for black cotton soil 1 cum. ( iv ) on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. ( v ) taking down all items in respect of existing earthing is included in the cost deemed to be quoted by contractor....
33866797 supply installation testing commissioning of battery backup system for vcb panel at new globe mill pumping station...
33756276 electrification work in pump house, office room, store room, 3.3 kv vcb panel room/ pump house work...
33080425 auction sale of lot no: 8.0 lot name: u/s 11 kv ht vcb panel...
32798770 barvi water works...m&r to barvi water works ,jambhul annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul. 2nd call...
32272253 tender for barvi water works...m&r to barvi water works ,jambhul ........annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul....
31869068 construction of vertical extension of 2 floors of new laboratory building at c met, pune. sh: replacement of existing 11kv ht vcb panel with suitable new vcb panel at c met, pune....
31837520 replacement of 11 kv ht mocb panel with 11 kv ht vcb panel at ats complex, mumbai....
31830970 replacement of 11 kv ht mocb panel with 11 kv ht vcb panel at ats complex, mumbai....
31791179 tender for barvi water works...m&r to barvi water works ,jambhul ........annual maintenance contract for ht vcb & panels at pure water & raw water pumping station, jambhul....
31757532 providing supplying spares and rectification of electrical and mechanical equipment in pump house and near waghur dam annual maintenance for year 2022 23 supply and installation of 33kv, 3 core, aluminum armored cable outdoor cable end termination joint kit ( isi make ) . work involve cutting of existing joint, measure insulation value and making joint, refixing to system. 2 supply & erecting 3.3 kv 3 core 300 sq.mm alum. armoured cable. 3 supply & erecting 3.3 kv 3 core 70 / 95sq.mm alum. armoured cable. 4 excavation and backfilling of trench for adjustment of33 kv cable for joint. 5 supply and installation of lt out door cable joint for auxiliary transformer 6 supply and installation of 33 kv isolator set of 3 with alignment 7 dismantailing of existing 33 kv isolator complete set 8 repairing of 33 kv existingisolator along with required spares & hardware’s with alignment for smooth operations 9 supply and installation of 33 kva b switchfor auxiliary transformer 10 dismantailing of existing 33 kva b switchcomplete set 11 repairing of 33 kv existing a b switchincluding required spares & hardwares with alignment for smooth operations 12 supply and installation of 33 kv horn gap unit of 3 with fuses 13 repairing of 33 kv horn gap post for proper fixing 14 supply and installation of horn gap fuses 15 supply and installation of33 kv , d o unit of 3 with fuses 16 supply and installation of d o fuse 50 amps 17 supply and installation of 33 kv, lasingle post 18 supply and installation ofpost insulator with pin 19 supply & installation of 33 kv outdoor pt 20 supply & installation of 33 kv outdoor ct 21 repairing of existing 33 kv outdoor pt 22 repairing of existing 33 kv outdoor ct 23 repairing of post insulator and cleaning by ctc 24 tightening of all conductors in sub station as preventiv maintenance 25 transformer, 33 kv / 3.3 kv, 3000 kva complete overhauling, bucolz relay, bdv test, ppm test, tightening of all 33 kv bushing and conductors removing air from bucolz relay, cleaning of all bushing with ctc. attending leakages if any. 26 transformer, 33 kv / 3.3 kv, 3000 kva. oil filtration with test report. 27 supply & installation of buchloz relay for 33 kv out door transformer. 28 supply & installation of breather with silica jel for 33 kv outdoor transformer. 29 auxiliary transformer 33 kv / 440 volts complete preventive maintenance. tightening of all bushing, gaskets, conductors and cable terminations, earthing etc 30 oil filtration of auxiliary transformer 33 kv / 440 volts 31 complete overhauling of 33 kv out door vcb.all control wiring tightening, spring changing motor testing, earthing tightening etc 32 earthing of sub station replace existing material by new material to improve value 33 spreading clear metal in yard 34 painting of complete structure of sub stations by red oxide as primer andaluminum paint 35 illumination in yard.supply and installation of fused tubes, bulbs wiring testing etc 36 supply and installationof indoor cable joint for 3.3 kv, 500 hp motor, coppermulti strandfor h t motor dismantailing of exi etcsting burnt out / heated cable joint, cleaning cable by ctcpreparing new joint and ht taping. 37 repairing of existing joint of 3.3 kv h t motor.cleaning by ctc to clean cable and lugs for carbon free particle’s, re taping by h t tape 38 supply and installationofh t capacitor ( 120kvar unit ) 39 supply ofl t capacitor 40 installation of l t capacitor 41 supply of h thrc fuse 3.3 kv / 50 amps capacity with barrel for capacitor 42 500 hp, 3.3 kv, h t motor complete overhauling with alignment. shifting motor from foundation by disconnecting cable, pulley etc. dismantailing / taking out rotor from stator. h t warnishing to rotor and stator by heating process inspection of bearings, end cover bearing housing etc 43 providing & fitting bearing to the motor de side including necessary fixtures etc. complete. 44 providing & fitting bearing to the motor nde side including necessary fixtures etc. complete. 45 workshop work for filling weared out bearing housing 46 rotor balancing for proper alignment to improve life of motor 47 painting to motor by red oxide as primer and two coats by smoke gray paint 48 preventive maintenance of motor. inspection of bearings, cable joints, foundation bolts tightness, cleaning of cooling system greasing to de nde bearings 49 replace of motor from foundation to other foundation 50 alignment of motor to pump 51 500 h.p. 375 kw. pump set ( kirloskar make ) remove of existing old splitcasing pump from row water pumping station for repairing purpose. 52 providing & fitting impeller to the pump including necessary fixtures etc. complete 53 providing & fitting pump shaft to the pump including necessary fixtures etc complete. 54 providing & fitting casing wear ring &suction side ) to the pump including necessary fixtures etc. complete. 55 providing & fitting casing wear ring ( delivery side ) to the pump including necessary fixtures etc. complete. 56 providing & fitting split gland to the pump including necessary fixtures etc. complete. 57 providing & fitting bearing holder de to the pump including necessary fixtures etc. complete. 58 rewinding motor of eot crane. 59 repairing panel board of eot crane with required accessories. 60 providing & fitting bearing cover de to the pump including necessary fixtures etc. complete. 61 providing & fitting bearing cap to the pump including necessary fixtures etc. complete. 62 providing & fitting split lantern ring to the pump including necessary fixtures etc. complete. 63 providing & fitting liquid deflector rubber to the pump including necessary fixtures etc. complete. 64 providing & fitting shaft sleeve to the pump including necessary fixtures etc. complete. 65 providing & fitting shaft sleeve nutto the pump including necessary fixtures etc. complete. 66 providing & fitting bearing nut to the pump including necessary fixtures etc. complete. 67 providing & fitting bearing lock nut to the pump including necessary fixtures etc. complete. 68 providing & fitting sealing tube to the pump including necessary fixtures etc. complete. 69 providing & fitting set of gaskets to the pump including necessary fixtures etc. complete. 70 providing & fitting set of ring to the pump including necessary fixtures etc. complete. 71 providing & fitting set of fasteners to the pump including necessary fixtures etc. complete. 72 providing & fitting gland packing to the pump including necessary fixtures etc. complete. 73 providing & fitting bearings to the pump including necessary fixtures etc. complete. 74 providing & fitting love joy coupling with rubber & studs complete with suitable bore size 75 providing nylon slings belts of 5 to 10 tan capacity ( for lifting purpose ) 76 pump coloring charges 77 eot crane maintenance work. inspection of main drum, motors, panel relays etc 78 replace faulty or burnt mcb in eot crane panel 79 overhauling ofmotors with replacement of bearings for eot crane 80 cleaning complete both rail of eot crane 81 h t panel inspection of all parts in one vcb panel for smooth operations 82 supply and installation of closing and tripping coil 83 supply and installation of spring charging motor 84 repairing of spring charging motor 85 supply and installation of spring charging drum mechanism 86 repair of vcb, inspection for smooth operations and trolley alignment 87 preventive maintenance of vcb 88 supply & installation of closing / tripping coil of vcb indoor 89 supply & installation of earth fault relay 90 supply & installation of thermostat 91 supply & installation of breaker control switches 92 lt panel supply and replacement of faulty / burnt outspaares 93 preventive maintenance of l.t. panel. 94 control and relay panel wiring replace by new whereever damaged 95 battery charger panel supply and installation of burnt out spares 96 preventive maintenance of battery charger panel 97 supply and installation of 110 volt dc batteries 98 preventive maintenance of 55 batteries 99 illumination system supply and installation of burnt tube lights, exhaust fans mcb, etc. 100 supplying spanner ( ring ) 101 supplying spanner ( fix ) 102 supplying multi meters 1000 amp. 103 supplying megger 1 kv ( 1000 volts ) 104 supplying pipe wrentch 18” 105 supplying pipe wrentch 24” 106 supplying pipe wrentch 36” 107 supplying chain pulley 2 tone 108 supplying chain pulley 3 tone 109 supplying hammer heavy weight up to 10 kg. 110 supplying air blower for panel, vcbcleaning purpose....
31654110 supply of set of spare for filter for dj/vcbset of spare for filter for dj/vcb,set of spare for filter for dj/vcb panel of siemag make model no.sb.ss.60.sh4 one set comprising of 7 items = 07 nos. as per drg.no. bsl/elw/sk no.9098....
31460865 tender for the work of repairing of 11kv ht vcb panel, lt panel,dg set, transformer, metering kiosk and allied work at bharat ratna dr .babasaheb ambedkar memorial, sec 15 airoli....
30983398 supply installation testing and commissioning of battery backup system for vcb panel and various ancillary electrical works at dadar pumping...
30717985 supply installation testing commissioning sitc of new 11 kv ht vcb panels and 2 nos. 630 kva transformers for substation mgims khs sevagram sitc of new 11 kv ht vcb panels and 2 nos. 630 kva transformers for substation at mgims khs sevagram...
30630834 auction sale of 1 voltage stabilizer 2 voltage stabilizer 3 voltage stabilizer 4 500 kva transformer ket make 5 500 kva transformer kirloskar make 6 630 kva transformer kirloskar make 7 voltage stabilizer automech electrical make 8 heat treatment old panel crompton parkinson make 9 busbar panel enterprises make 10 cooling pump control desk eta dogiguard make 11 d .g. control desk sorana digiguard make 12 synchronising control desk sorana digiguard make 13 load control desk sorana digiguard make 14 high voltage ct mahadev ele. pune make 15 out door breaker panel cg make 16 out door breaker panel cg make 17 heavy foundry breaker panel schneidler make 18 heavy foundry furnace acb l t make 19 hrc control panel shree control make 20 vcb controle panel pce make 21 vcb controle panel 22 rtcc panel kec make 23 battery charger panel nana make 24 flot coin boost battery charger panel sm interface make 25 controle panel kbl make 26 compressor kbl make 27 air driyer 28 air driyer filter 29 ele .motor kirloskar make 30 ele .motor kirloskar make 31 vcb panel vibha corporation make 32 distribution panel ...
30536105 tender document for [supply, fixing spare parts and servicing 22 kv megawin make indoor vcb panel and gec alsthom make lt acb panel installed at our container freight station, dronagiri, navi mumbai...
30435358 bids are invited for 1. manpower outsourcing services minimum wage skilled; others; electrician outsourcingof services for manning & operation of e/m installation comprising ht vcb, panel board, feeder pillar, street lights and auto power factor control at kalina campin 03 (three) shifts of 8 hourseach per day including sundays and holidays by providing and deploymentone electrician (skilled) in each shift including routine maintence, attending and rectification of breakdowns daily,cleaning and up keep of surrounding areas of installations and maintaining record of daily break down of installation as and when maintenance carried outall as directed by engineer in charge. timings of shifts: shall be as directed by engineer in charge. note: electrical items/spares as per requirement of site shall be arranged for issue through baby indent by the department. old unserviceableitems/spares shall be deposited by the contractor at their own cost to age e/m (af) mumbai store yard. , 2. manpower outsourcing services minimum wage skilled; others; electrician outsourcingof services for manning & operation of e/m installation comprising ltfeeder pillar box/panel and auto power factor control at coo hangar,121 hf annex bldgs and porta cabin in 03 (three) shifts of 8 hourseach per day including sunday and holiday by providing and deployment one electrician (skilled) in each shift including routine maintence , attending and rectification of breakdowns daily,cleaning and up keep of surrounding areas of installations and maintaining record of daily break down of installation as and when maintenance carried outall as directed by engineer in charge.timings of shifts: shall be as directed by engineer in charge.note: electrical items/spares as per requirement of site shall be arranged for issue through baby indent by the department. old unserviceableitems/spares shall be deposited by the contractor at their own cost to age e/m (af) mumbai store yard. , 3. manpower outsourcing ...
29461804 tender for various repairing and development work, erection of chlorinator, repairing and maintenance of water supply, providing and fixing, testing of vcb panel, laying of drainage line, patch work of road....
29307781 supply of rmu unit vcb panel , ...
29153951 repair and comprehensive maintenance of transformer vcb panel ht cable and connected items at af station ojhar repair and comprehensive maintenance of transformer vcb panel ht cable and connected items at af station ojhar...
28988984 scw vcb panel at erai dam cstps...
28984759 bids are invited for boq total quantity : 1 vcb panels, 11 kv, 800 amps, indoor type...
28835652 tender for scw vcb panel at erai dam cstps...
28487885 repair and comprehensive maintenance of transformer , vcb , panel , ht cable and connected items at af station devlali...
28408203 supply installation testing commissioning of new 11 kv ht vcb panels and 2 nos . 630 kva transformers for substation at mgims khs sevagram sitc of new 11 kv ht vcb panels and 2 nos . 630 kva transformers for substation at mgims khs , sevagram...
28388572 execution of electrical works relating to modification of ht metering system . supply , installation , testing and commissioning of 33 kv vcb panel , metering kiosks , compact sub stations including supply and laying of ht and lt cables...